View Bid Results For Rs485 Tenders

We found 445 Bid Results related to rs485 tenders. You can find Contractor details who won rs485 tenders along with contract details in Bid awards announcements section.

Filters
Stage
347
70
28
Tender Publishing Platform
167
278
State / UT
29
57
41
35
34
30
29
25
24
20
18
18
16
15
14
10
8
8
7
7
7
7
4
3
3
1
1
1
1
1
Contract Value
144
127
113
61
Publish Date
2
0
0
0
0
Sector
29
65
51
41
40
33
33
26
21
18
16
16
14
13
9
9
8
7
4
3
3
2
2
2
2
2
1
1
1
1
Ownership
6
212
87
84
46
13
2
Within keyword
Active filters:
Showing 1–9 of 445 tenders matching your filters
1.
Power #11459403 Technical Bid
Tender for Supply, Installation And Commissioning Of The Flow Transmitters At Various Locations Of Unit # 1 To 4,Ctpp,Rrvunl,Chhabra , Insertion Type Electromagnetic Flow Meter Transmitter/Electronics Mounting - Remote (10 Mtr Max) Power Supply - 220 V Ac, Enclosure Moc - Al Die Cast, Enclosure Ip Rating - Ip67, Hazardous Certification - Na, Electrical Connection - M20, Electrical Output 1 (Current) - 4 To 20 Ma, Electrical Output 2 (Pulse) - Na, Electrical Output 3 (Alarm /Relay ) - Na, Alarm Type - Na, Communication Output 1 - Rs485, Communication Output 2 - Na, Flow Tube - 200 Nb To 600Nb, Mounting Type - Hot Retractable, Process Connection - Flanged ( 200 To 3000 Nb). Flow Range = 2000 M3/Hrs. Comments: Suitable For Line Size 600 Nb Accuracy: ±2 % Of Measured Value Or ±2 Mm/S With Storage Data For One Year & Data Importing Facility To Laptop/Usb/Computer , Insertion Type Electromagnetic Flow Meter Transmitter/Electronics Mounting - Remote ( 10 Mtr Max ), Power Supply - 220 V Ac, Enclosure Moc - Al Die Cast, Enclosure Ip Rating - Ip67, Hazardous Certification - Na, Electrical Connection - M20, Electrical Output 1 (Current) - 4 To 20 Ma, Lctrical Output 2 (Pulse) - Na, Electrical Output 3 (Alarm /Relay ) - Na, Alarm Type - Na, Communication Output 1 - Rs485, Communication Output 2 - Na, Flow Tube - 700Nb To 1000 Nb, Mounting Type - Hot Retractable, Process Connection - Flanged ( 200 To 3000 Nb). Flow Range = 4500 M3/Hrs. Accuracy: ±2 % Of Measured Value Or ±2 Mm/S Comments: Suitable For Line Size 900 Nb With Storage Data For One Year & Data Importing Facility To Laptop/Usb/Computer , Insertion-Type Electromagnetic Flow Meter Assembly With Mounting Enclosure Pipe Diameter 600 Mm To 1800 Mm. Technical Specifications Are As Below , Insertion Type Electromagnetic Flow Meter Transmitter/Electronics Mounting - Remote ( 10 Mtr Max ), Power Supply - 220 V Ac, Enclosure Moc - Al Die Cast, Enclosure Ip Rating - Ip67, Hazardous Certification - Na, Electrical Connection - M20, Electrical Output 1 (Current) - 4 To 20 Ma,E Lctrical Output 2 (Pulse) - Na, Electrical Output 3 (Alarm /Relay ) - Na, Alarm Type - Na, Communication Output 1 - Rs485, Communication Output 2 - Na, Flow Tube - 200Nb To 600 Nb, Mounting Type - Hot Retractable, Process Connection - Flanged ( 200 To 3000 Nb). Flow Range = 4500 M3/Hrs. Accuracy: ±2 % Of Measured Value Or ±2 Mm/S;Comments: Suitable For Line Size 600 Nb,Pipe Dia:-600 Nb, Od:- 610Mm, Thickness:-08Mm With Storage Data For One Year & Data Importing Facility To Laptop/Usb/Computer , Insertion Type Electromagnetic Flow Meter Transmitter/Electronics Mounting - Remote ( 10 Mtr Max ), Power Supply - 220 V Ac, Enclosure Moc - Al Die Cast, Enclosure Ip Rating - Ip67, Hazardous Certification - Na, Electrical Connection - M20, Electrical Output 1 (Current) - 4 To 20 Ma,E Lctrical Output 2 (Pulse) - Na, Electrical Output 3 (Alarm /Relay ) - Na, Alarm Type - Na, Communication Output 1 - Rs485, Communication Output 2 - Na, Flow Tube - 200Nb To 600 Nb, Mounting Type - Hot Retractable, Process Connection - Flanged ( 200 To 3000 Nb). Flow Range = 4500 M3/Hrs. Accuracy: ±2 % Of Measured Value Or ±2 Mm/S Pipe Dia:-1800 Nb,Od:- 1829Mm, Thickness:-14Mm, Comments: Suitable For Line Size 1800 Nb, With Storage Data For One Year & Data Importing Facility To Laptop/Usb/Computer , Inline Electromagnetic Flow Meter Assembly With Mounting Enclosure (For Line Size: 125 Mm) Transmitter/Electronics Mounting - Remote ,Power Supply - 230 Vac Enclosure Moc - Al Die Cast; Enclosure Ip Rating - Ip68; Hazardous Certification Only For Electronics Enclosure -Na; Electrical Connection - 1/2 Npt; Electrical Output 1 (Current) - 4 To 20 Ma; Electrical Output 2 (Pulse) - Pulse (Oc); Electrical Output 3 (Alarm /Relay) - One Alarm;Alarm Type - Open Collector; Communication Output 1 - Rs485; Communication Output 2 - Na; Pressure Sensor - Na; Flow Tube - As Per Line Size Electronics Location - Remote; Remote Signal Cable Length - 10Mtr; Process Connection - Flanged (15 To 1000 Nb);Flange Moc - Cs; Flange Standard - Din Pn 16 En 1092-1; Lining Material - Hard /Ebonite Rubber; Electrode Material - Ss316l; Inline Pressure Sensor - Na; Comments: 1.Process Medium: Raw Water 2. Operating Temp.:0 To60 Deg C 3. Accuracy:+/-0.5% Of M.V With Storage Data For One Year & Data Importing Facility To Laptop/Usb/Computer , Ultrasonic Flowmeter Assembly With Mounting Enclosure :- Non-Contact Clamp On Fixed Type Ultrasonic Flowmeter With Anti Bubble Characteristics Pipe Diameter 25 Nb To 225Nb. Technical Specification As Enclosed In Annexure- I , Sensor Assembly For Item Sr. No. 5 Sensor: For Pipe Diameter 25Nb To 225 Nb With Extendable Guide Rail Type Mounting Belt: Stainless (1.0Mx2) & Signal Cable: 10 Mtr Co-Axial Cable. Technical Specification As Enclosed In Annexure- I , Ultrasonic Flow Meter Assembly With Mounting Enclosure :- Non-Contact Clamp On Fixed Type Ultra Sonic Flowmeter With Anti Bubble Characteristics. Pipe Diameter 50 Nb-225Nb. Technical Specification As Enclosed In Annexure- I , Sensor Assembly For Item Sr. No. 7 Sensor: For Pipe Diameter 50 Nb-225Nb With Extendable Guide Rail Type Mounting Belt: Stainless (1.0Mx2) & Signal Cable: 10 Mtr Co-Axial Cable. Technical Specification As Enclosed In Annexure- I , Ultrasonic Flowmeter Assembly With Mounting Enclosure :- Non-Contact Clamp On Fixed Type Ultrasonic Flowmeter With Anti Bubble Characteristics Pipe Diameter 25 Nb To 225Nb. Technical Specification As Enclosed In Annexure- I , Sensor Assembly For Item Sr. No. 9 Sensor: For Pipe Diameter 25Nb To 225 Nb With Extendable Guide Rail Type Mounting Belt: Stainless (1.0Mx2) & Signal Cable: 10 Mtr Co-Axial Cable. Technical Specification As Enclosed In Annexure- I , Ultrasonic Flowmeter Assembly With Mounting Enclosure :- Non-Contact Clamp On Fixed Type Ultrasonic Flowmeter With Anti Bubble Characteristics Pipe Diameter 50Nb To 225Nb. (Technical Specification As Enclosed In Annexure- I) , Sensor Assembly For Item Sr. No. 11 Sensor: For Pipe Diameter 50Nb To 225 Nb With Extendable Guide Rail Type Mounting Belt: Stainless (1.0Mx2) & Signal Cable: 10 Mtr Co-Axial Cable. (Technical Specification As Enclosed In Annexure- I) , Insertion Type Electromagnetic Flowmeter For Line Size 500Mm Insertion Type Electromagnetic Flow Meter Transmitter/Electronics Mounting - Remote (10 Mtr Max) Power Supply - 220 V Ac, Enclosure Moc - Al Die Cast, Enclosure Ip Rating - Ip68, Hazardous Certification - Na, Electrical Connection - M20, Electrical Output 1 (Current) - 4 To 20 Ma, Electrical Output 2 (Pulse) - Na, Electrical Output 3 (Alarm /Relay ) - Na, Alarm Type - Na, Communication Output 1 - Rs485, Communication Output 2 - Na, Flow Tube - 200 Nb To 600Nb, Mounting Type - Hot Retractable, Process Connection - Flanged ( 200 To 3000 Nb). Comments: Suitable For Line Size 500 Nb Accuracy: ±2 % Of Measured Value Or ±2 Mm/S With Storage Data For One Year & Data Importing Facility To Laptop/Usb/Computer , Inline Electromagnetic Flow Meter For Line Size 200Mm Inline Electromagnetic Flow Meter Assembly With Mounting Enclosure. Transmitter/Electronics Mounting - Remote ,Power Supply - 230 Vac Enclosure Moc - Al Die Cast; Enclosure Ip Rating - Ip68; Hazardous Certification Only For Electronics Enclosure -Na; Electrical Connection - 1/2 Npt; Electrical Output 1 (Current) - 4 To 20 Ma; Electrical Output 2 (Pulse) - Pulse (Oc); Electrical Output 3 (Alarm /Relay) - One Alarm; Alarm Type - Open Collector; Communication Output 1 - Rs485; Communication Output 2 - Na; Pressure Sensor - Na; Flow Tube - As Per Line Size Electronics Location - Remote; Remote Signal Cable Length - 10Mtr; Process Connection - Flanged (15 To 1000 Nb); Flange Moc - Cs; Flange Standard - Din Pn 16 En 1092-1; Lining Material - Hard /Ebonite Rubber; Electrode Material - Ss316l; Inline Pressure Sensor - Na; Comments: 1.Process Medium: Raw Water 2. Operating Temp.:0 To 60 Deg C 3. Accuracy:+/-0.5% Of M.V With Storage Data For One Year & Data Importing Facility To Laptop/Usb/Computer
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Contract Date: Ref. Documents Contract Value : 4.14 Lakh
Government Departments No of Bidders 4
3.
Public Administrative Department #11415442 Price Bid
Tender for Site Of Ccms At Various Places Of Municipal Board Marwar Junction Area -Supply installation testing & commissioning of IK08 & IP56 3 phase 440V 50Hz, 7.5kw capacity centralized control and monitoring system panel (CCMS) made of fire retardent SMC steel material having lock & suitable for schedule on/off of street lights having following provision: Inbuilt on chip integreted energy metering with 3 nos CT having class 1 accuracy, Three phase auto phase selector power supply with withstanding capability up to 500 VAC, Instant mode, Fixed Mode, Astronomical Mode, Hybrid Mode, Interval Mode, Offset in Sunset and Sunrise Timing for scheduling, Provision for measurement of all three phase electrical parameters like voltage, current, power factor, power, frequency, energy with atleast class 1 accuracy and compliant with IS13779 standard, UV-OV protection, backup battery 8 hrs, Andriod/iOS app and software to operate form computer, provision to add display device externally, support for RS485 communication, inbuilt GSM/GPRS 4G modem modem with 2G fallback, Real time GPS based clock, calendar, lithium ion battery backup for RTC clock, Three relay output, Minimum Ninety days data memory inbuilt backup facility, Controller shall be type tested with NABL approved lab for EFT or burst testing for conducted immunity in accordance with IEC 610000-4-4, For Future upgradation CCMS panel shall supports wireless Low Power Sub Ghz (865-867 MHz) communication with a maximum 100 nos. of individual node/Luminaire controller which can monitor ON/OFF status & Flicker detection of led lamp up to 400W. Network should support self-forming and self-healing RF mesh with open field range of 200 m. CCMS panel enclosure shall be made of Mild Steel material of minimum 16 gauge with MS base sheet of appropriate thickness. It shall have Four Pole Incoming MCB of 63 Amp, Single Pole Outgoing MCB of 32 Amp, 3 latching Relays with 63 Amp and 2P Rotary switch and MCB for Maintenance and Bypass Operation. Software should have undergone a Vulnerability Assessment and Penetration Testing (VAPT) as per OWASP, SANS CWE 24 or CERT-In Standard. Dedicated IoT communication GSM/GPRS SIMCard (with minimum 2 years of recharge)for 4G Communication with software application. 2 Year Data Hosting & Server Charges to be included with software. Software application should utilize a Low-Code/No-Code platform to simplify development and customization. It must be hardware-agnostic and compatible with other loT-based smart city applications. Pole mounting/surface mounting stand shall be included.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
4.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
7.
Public Administrative Department #11306613 AOC
Tender for Electromagnetic Flow Meter Shall Be A Velocity Sensing Electromagnetic Type, Microprocessor Based Signal Converter, Sealed Housing, Flanged Tube Meter For 1.0 Mpa Working Pressure, Manufactured To Highest Standard Available For Mag-Meters, Equipped With Minimum Six Digit Digital Totalizers, Reading In Units Of (Kilolitres/ Cubicmeter) And Shall Be Accurate Within 0.5% Of Measured Value, Shall Operate Within A Range Of 0.3M/Sec To 4 M/Sec And Be Constructed As Follows:Meter Tube (Sensor) Shall Be Fabricated From Stainless Steel Tube And Use Class Pn10 Flat Face Carbon Steel Flanges In Accordance With Is 1538. These Flanges Shall Be Welded To The Flow Tube. The Internal And External Of The Meter Tube Shall Be Blasted To Near White And Lined With Hard Rubber/ Polyurethrene/ Ptfe Preferably By Sbr Or Epdm. Meter Tube Shall Have A Constant Nominal Inside Diameter Offering No Obstruction To The Flow. The Accuracy Should Be Inclusive Of Linearity, Hysteresis, Repeatability, Temperature And Pressure Effects Coil Housing Shall Be Fabricated From Stainless Steel (Ss 304) With Anticorrosive Paint For Corrosion Resistance And Welded To The Tube Providing A Completely Sealed Environment For All Coils, Electrode Connections And Wiring Harness Capable Of Submerged Or Buried Operation With Ip 68 Protection. Signal Converter Shall Be Pulsed Dc Coil Excitation Type With Auto Zeroing. The Signal Converter Shall Be Remotely Mounted Away From The Meter. The Converter Shall Indicate Direction Of Flow And Provide A Flow Rate Indication And A Total Of Flow Volume For Both Forward And Reverse Directions. The Converter Shall Provide An Isolated 4-20 Ma Output Into Minimum 500-Ohm Load And A Frequency Output Of A Maximum Of 0-10 Khz And A Scaled Pulse Output, Communication Interface Is Rs485, Hart Output, . The Microprocessor Based Signal Converter Shall Have A Selfdiagnostic Test Mode And A Backlit Display That Continuously Displays Rate Of Flow And Total Volume. Converter Shall B
Contract Date: Jun 17, 2026 Contract Value : 8.27 Lakh
Local Bodies No of Bidders 2
8.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
9.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
11.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 5.11 Lakh
Boards / Undertakings / PSU No of Bidders 2
Madhya Pradesh View Result →
13.
Power #11176094 Price Bid
Tender for Supply Of Electrical Items And Stores Hardware Items For Sub-Transmission Division-Ii, Jpdcl, Jammmu For The Year 2026-27 , 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) Raychem, 3M, Densen Or Equivalent A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 185 Mm2 , R) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 300 Mm2 , S) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 400 Mm2 , T) Cable Kits 11 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , U) Cable Kits 33 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , 33 Kv, 3Cx400 Sq Mm , Touch Proof Kit, Screen Separable Elbow Termination Connector/Kit, Confirming To En 50180/En 50181 (Raychem/Denson/3M) , 33 Kv 3Cx400 Sq Mm Xlpe Aluminium Power Cable , Spares For 33 Kv C&R Panels And 11 Kv Vcb/Ocb Panel Banks. A) Inner Baffle For 33 Kv Mocb Bhel , C) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bhel Make , D) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bicco Lawrie Make , E) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Crompton Greaves Make , F) Trolly Copper Bushing Rod Suitable For11 Kv Ocb Panel Ssg Make (Parma Wood)/Crompton Greaves Make , G) Male Contact For 11 Kv Ocb Bicco Lawrie Make (Copper) With Silver Coating 11 Ocb Panel , H) Male Contact For 11 Kv Ocb S.S.G Make (Top Tip Of Iron) With Silver Coating , I) Male Contact For 11 Kv Ocb Crompton Greaves Make (With Silver Coating) , J) Male Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , J) Male Contact For Ocb Mei Make (With Silver Coating) , K) Female Contact For 11 Kv Ocb Bicco Lawrie Make (With Silver Coating) , L) Female Contact For 11 Kv Ocb S.S.G Make (With Silver Coating) , M) Female Contact For 11 Kv Ocb Cromption Greaves Make (With Silver Coating) , N) Female Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , O) Trip Bridge Assembly (Bl) , P) Roller Assembly (Bl) , Q) Female Contact For 11 Kv Ocb Mei Make (With Silver Coating) , R) 11 Kv Pt Fuse , S) 11 Kv Vcb Bottle Assembly Bracket , T) Shower Contact Mei Make , U) Shower Contact Crompton Greaves Make , V) annual rate contract Pot Mei Make , W) Tripping Coil Suitable For 33 Kv And 11 Kv Ocb / Vcb Panels (Operating Voltage 30-36 Volt Dc) , X) Tripping Coil For 66 Kv Ocb / Vcb Panels , Ammeter Selector Switches , Voltage Selector Switches , Multifunction Transducer, Rish Master 3450 Model, Class 0.2S, Input: 3Ph, 100-600V L-L, 5A/1A, 45....65 Hz, With Rs485 Output, Aux Voltage: 1260V Ac/Dc , Contact Multiplying Relay, Salzer, Mkp 2P 30S, Coil Voltage : 30 V Dc , Master Trip Relay, Alstom Make, Mvajm15ja0204a Model, 30-34 V Dc , Master Trip Relay, Abb Make, Pq8nch2js Model, 30V Dc , Master Trip Relay, Ashida Make, Avajh13-Am-011-03-01-6-00-00-00, 4 No + 1Nc Hr Model, 24/30V Dc , Micom Alstom Relay ( For 11 Kv Panels), Model: P14nb16a6c0610a , Ref615, Abb Make Feeder Protection Relay, Product Order Code: Hbfnaeagnda1baa21g ( For 11 Kv Cr Panels) , Ret615, Abb Make Differential Complete Relay ,Product Order Code: Hbtdbabanda1ann21g ( For 33 Kv Cr Panels) , Control Card For Ret615 Abb Relay , Bio0005 2Rca025501a0001e 2Rca024987d , Power Card For Ret 615 Abb Relay, Psm0903 2Rca025058a0901p 2Rca024584m , Space Heaters, 230 V Ac, 200W , Thermostat: 230 V Ac, 5-60 Deg Celcius , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm/ Megawin/ Sudhir/Electricfield For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii) 750/375/5-5-5 , Iii) 600/300/5-5-5 , Iv) 600/300/5-5-5 , V) 400/200/5-5 , Vi) 300/150/5-5 , Vii) 150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , C) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , C) Breather For 5 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 6.3 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 10 Mva 66/11 Kv Transformer (3 Kg) , D) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , E) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , F) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , G) Silica Gel , H) Oil Seal For 33/11 Kv Power Transformer , I) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Oil Temperature Indicator 6-Inch Dia , Winding Temperature Indicator 6-Inch Dia , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm , 10 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 8 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 6 Mm Thick , Relays A) Numerical Relay 3-Pole (24-50 V) 3 O/C And 1 E/F Relay ( Abb Ref615/Ge Alstom) , B) Master Trip Relay 24-50 V , B-24 , C) Master Trip Relay Ashida (Make) 18-52 (V) , D) Ashida Numerical Relay 2 O/C & 1 E/F , 33 Kv & 11 Kv Insulators Make Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) With Base Pin 25 Mm , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) With Base Pin 25 Mm , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) 11 Kv Guy Insulator , P) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type (Approx. 2.8 Kg) , 33 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type (Approx. 3.8 Kg) , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type (Approx. 4.6 Kg) , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor (Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsr Panther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsr Wolf Conductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsr Dog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , G.I. Spring Washers , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape , Empire Tape , Para Plast Compound , Earth Wire , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Lights , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots , Search Light / Dragon Light With In Built Charging System , 33 Kv Electrical Safety Gloves (Meet Or Exceed Astm D120 And Iec En60903 Standards) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Electrical Insulating Rubber Matting Iec/Bs En 61111:2009 , Megger 500V-1000V-2500V-5000 V ( All In One) With Pi Feature , Non-Contact High Voltage Detector (Wrist Type) 1Kv To 500Kv , Ip54 Protection Level , Frp Telescopic Earth/Discharge Rod For 11 To 33 Kv System (Assemble Length:-20 Feet) , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , I/C Switch 200 annual periodical maintenance , Fire Extinguisher For Electrical Sub Stations Of Relevant Is Specifications , A)Co2 (4.5 Kg) , B) Power Based (Abc Type) 4 Kg. , C) Power Based (Abc Type) 6 Kg. , D) Power Based (Abc Type) 9 Kg. , Fire Buckets With Stand , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 annual periodical maintenance (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 annual periodical maintenance (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 annual periodical maintenance (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 annual periodical maintenance (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 11 Kv Hg Set , 11 Kv Do Set , 11 Kv G.O Set , 11 Kv Link Set With 50 Mm Copper Strip , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank & Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cells Complete With All Accessories , 30V, 25A Battery Charger Automatic (Float & Boost) Thyristor Based Chargers (Compatible For Vrla Batteries) , B) 30 annual periodical maintenance Manually Operated Battery Charger. , C) Maintenance Free 30 V Lead Acid Battery (Vrla) Bank Comprising Of 16 Nos Of 2 Volt Cells Of 100 Ah Capacity , D) 30 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 30 Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Rectifier , Delta ( detail project report 2000B-24), Id:A2, Input ( 100-240V Ac, 15A Max, 50-60 Hz), Output ( 26.7 V Dc, Max: 2000 W Suitable For Use In Delta Electronics (I) Pvt Ltd Make, Model: 30V Dc Dcps, Smps Based Dc Power System. , Main Control Card Suitbale For Use In - Fcbc Make: Digital Electric (P) Ltd , Input 1Ph, 230 V , 50 Hz & Output Float: 33.4 V Dc Boost: 34.5 V Dc, 40 A Charger) , Lightening Arrestors (10 Ka, Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) A) 11 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , B) 33 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , C) 11 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , D) 33 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , Control Cable Armoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , Control Cable Unarmoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle (1200A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , 11 Kv Vacume Interupter Bottle (800A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , H.T. Tape , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 B) 33 Kv, 3 Phase Xlpe Cable 400 Mm2 C) 33 Kv, 3 Phase Xlpecable 300 Mm2 , D) 11 Kv Single-Core Xlpe Cable 630 Mm2 , E) 11 Kv 3-Core Xlpe Cable 400 Mm2 , F) 11 Kv 3-Core Xlpe Cable 300 Mm2 , G) 11 Kv 3-Core Xlpe Cable 240 Mm2 , H) 11 Kv 3-Core Xlpe Cable 185 Mm2 , I) 11 Kv 3-Core Xlpe Cable 120 Mm2 , J) 11 Kv 3-Core Xlpe Cable 95 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured X35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm Φ (1½) , E) G.I. Pipe 50 Mm Φ (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , 66 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendments Up To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb , 33 Kv C&R Transformer Panel With Differential Protection , 33 Kv C&R Line Panel , 66 Kv Ct Of Different Ratios , 66 Kv Pt Of Different Ratios , 66 Kv La Set , 66 Kv Isolator Set With Earthing Blades , 66 Kv Isolator Set Without Earthing Blades , 66 Kv C&R Transformer Panel , 66 Kv C&R Line Panel , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Street Light / Yard Light (100 Watt) , Street Light / Yard Light (250 Watt) , Led Bulbs (9W) Isi Mark , Led Bulbs (15W) Isi Mark , Led Bulbs (30W) Isi Mark , Led Bulbs (50W) Isi Mark , Lifting & Pulling Machine (Capacity 5 Ton To 8 Ton) , Safety Chart 3X2 Ft, Laminated Board , 11 Kv Indoor Incomer Vcb Panel 1250 A , 11 Kv Outdoor Vcb Panel 1250 A , 11 Kv Indoor Incomer Vcb Panel 800 A , 11 Kv Outdoor Vcb Panel 800 A , Exhaust Fan 20 Inches, Heavy Duty , Digital Multimeter Of Standard Ratings , Digital Clampmeter 1000 A, Ac/Dc , Aet 23 Earth Tester , Agm Alct 60 A, Ac/Dc Leakage Clampmeter , Insulation Tester 5 Kv, (Ithv-501000), 0-100000 Mω (Voltage-5000 V) , 11 Kv Earthing Rod , 33 Kv Earthing Rod , Iron Of Sorts Ms Angle 50X50x6 , Ms Flat 50X6 , Ms Angle 65X65x6 , Ms Channel 100X50x6 , 11 Kv Capacitor Banks Apfc Relay, Siemens, Model: 7Ug0571-1Ft20 , Apfc Relay, Unistar, Model: Us-Ht-5004 , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 600 Kvar Stage. Reactor Rating 1 Ph = 0.40 Kvar, Inductance /Phase = 1.70 Mh, Reactance/ Phase = 0.53 Ohms, Rated Volatge = 11 Kv , Rated Current = 27.38 A, Class Of Insulation = F , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 1200 Kvar Stage. Reactor Rating 1 Ph = 0.80 Kvar, Inductance /Phase = 0.85 Mh, Reactance/ Phase = 0.27 Ohms, Rated Volatge = 11 Kv , Rated Current = 54.77 A, Class Of Insulation = F , 11 Kv Indoor Epoxy Resin Cast Residual Volatge Transformer, 3-Phase 5 Limb, 11 Kv/√3/110V/√3-190V, , Tar Steel 8 Mm , Tar Steel 10 Mm , Tar Steel 12 Mm , Tar Steel 16 Mm , Tar Steel 20 Mm , Cement , Ht Tape For Xlpe Cables , 33 Kv Isolator With E/B (Porcelain) , 34 Kv Isolator Without E/B (Porcelain) , True Rms Digital Multimeter (Rishabh / Fluke / Megger) , 0-20 A, Digital Clamp Meter (Rishabh / Fluke / Megger) , 11Kv Pt Indoor Type Resin Cast 11 Kv/110V (3 Nos) , 11Kv Pt Draw Out Type Along With Housing 11 Kv/110V (1 Complete Set) , 11 Kv Vaccum Interrupter Type Vge4 Abb Make For Pascal Vcb , 11 Kv Vaccum Interrupter Stelmac Make , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Electricfield , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Pascal , Copper Resin Cast Busbar Grid Spout For 11 Kv Vcb Stelmac , Spring Charge Motor For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Out Door Type Ovb-Vbf 36.20.25 Make Abb , Tripping Coil Copper For 33 Kv Vcb Stelmac , Micom Alstrom P14n Relay With 61850 Scada Compatibale Port , Ashida Make Relay Adr 241B With 61850 Scada Compatible Port , Ashida Make Relay Adr 241A Non Scada , Ashida Realy Adr 141C , Master Trip Relay Alstrom Make , Led Indicator 36 V Dc , Ethylene Propylene Rubber (Epr) Self Amalgamating Tape 38Mmx9mtr Scapa/3M , Ampere Selector Switch , 66 Kv Disc Insulator B&S Type Polymer , 66 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Wolf Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , 66 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type With Ball Socket 90 Kn , Battery Charger Automatic Float-Cum-Boost Charger Input 190-230 V Ac 1Ph, Output 30 V Dc 25 annual periodical maintenance With Full Wave Rectification, Output Float Voltage: 33.0 Vdc Output Boost Voltage: 35.0 Vdc With Test Report. , Frp Extendable Ladder Of 10M , Polywater® Powerpatch® Transformer Seal And Pilc Cable Repair Allow For The Repair Of Active Leaks In The Field , Wrist Type High Voltage Detector , Hydraulic Crimping Tool Upto 630 Sq Mm Size , Digital Earth Clamp Tester , 60 Kv Motorised Oil Bdv Kit , Switch Disconneter Fuse 160 A , Mcbs 63A , 9 Mtr. St Poles , 11 Mtr. St Poles , 13 Mtr. Poles , Gaskets Of Of All Sorts For Power Transformer , 33 Kv Frp Crossarm , Frp Channels Of (100X50x6) Mm , Frp Angles Of (65X6)Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
14.
Railways #11130496 AOC
Supply Of goods, n & s aspirating type fire/smoke detection. , goods, n & s aspirating type fire/smoke detection with alarm system to rdso specrdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part. four zone conve ntional fire alarm panel with gsm. batteries excluded with power wiring, part no. ns-train18-cp-fire panelpcb, operating voltage: 24vdc, 3a power consumption: suitably <3w no of zones: 04 lcd disp lay/rs485/keypad program gps/gprs. make: n&s solutions. [ warranty period: 30 months after the date of delivery ] ] , goods, n & s aspirating type fire/smoke detection with alarm system to rdso specrdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part. tcms card with s ub-d wiring, part no. ns-train18-cp-tcmscard, operating voltage: 24vdc rx/tx leds supports rs4 85/tcms protocol. make: n&s solutions. [ warranty period: 30 months after the date of delivery ] ] , goods, n & s aspirating type fire/smoke detection with alarm system to rdso specrdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part hooter with st robe, part no. ns train-18-cp-audio-alarm, supply: 24vdc, power: 350ma max operating temper ature: +10-80degree c sound: 85-100db air humidity: to 95%rh color red. make: n&s solutions. [ wa rranty period: 30 months after the date of delivery ] ] , relay card assembly with wiring part no-cp-firelink-25/100 rc input relay ca rd, aspirating type fire/smoke detection with alarm system to rdso spec-rdso/2008/cg-0 4/rev-06 for train 18 model-ns-hochiki-1060.01. make: n&s solutions. [ warranty period: 30 mon ths after the date of delivery ] ] , goods, n & s aspirating type fire/smoke detection with alarm system to rdso specrdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part firelink25 1 pipe hssd& dock station (air flow suction fan) part no. nstrain18- cp-hochiki flnk 25-006, suppl y voltage: 21.6-26.4vdc current consumption: 250ma @ 24vdc relay contact rating: 500ma @30v measurement range (obs/m):0303%25% (fds) 0.0015% to 25% sensitivity resolution. make: n&s solu tions. [ warranty period: 30 months after the date of delivery ] ] , goods, n & s aspirating type fire/smoke detection with alarm system to rdso spec rdso/2008/cg-04/rev-05 for train 18 model-ns-hochiki-1060.01 spare part. dc converter (1 10v to 24 vdc) assembly, part no. ns-train18-cp-dcdc converter, input-70-300vdc, output -24-2 7vdc=3amps line regulation<1%. make: n&s solutions. [ warranty period: 30 months after the date of delivery ] ]
Contract Date: May 20, 2026 Contract Value : 4.67 Lakh
Government Departments No of Bidders 1
15.
Drinking Water Supply and Sanitation #11129348 Technical Bid
Tender for Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (50 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (70 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (95 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (120 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (185 Sqmm Size) , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 250 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 400 Mm Nominal Diameter , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 400 Mm Nominal Diameter , Supply Erection Testing Of Reputed Make Led Light 100 Wats With Fittings And Accessories Complete In All Repects. , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 350 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 350 Mm Nominal Diameter , Providing, Fixing, Jointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Ns Item -Providing And Fixing Of Ci Sluice Valves Conform To Is 14846 / Din 3352, With Length Over Flanges As Per Pd Or Alt 1 Of Is 14846 Corresponding To Bs En - 558 / Iso 5752 Basic Series 3 And 15 Respectively Including Labour, Material, Joints. Make: Ivc / Vag / Kirloskar Complete In All Respect As Per Specifications Mentioned In Dnit 800 Mm I/D , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 13200 Lpm X 20 Mtr. Head (For Mps Idgah Road) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 8800 Lpm X 20 Mtr. Head (For Mps Idgah Road) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 100 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Mps Idgah Road) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 65 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Mps Idgah Road) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 35 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Mps Idgah Road) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 4000 Lpm X 30 Mtr. Head (For Ips Mc Land) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 7800 Lpm X 30 Mtr. Head (For Ips Mc Land) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 11800 Lpm X 30 Mtr. Head (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 130 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 90 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 45 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 35 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips-2 Near Stp) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 75 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips-2 Near Stp) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 9600 Lpm X 20 Mtr. Head (For Ips-2 Near Stp) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
16.
Communications and Information Technology  #11104520 AOC
Tender For supply installation testing and commissioning Of It Infrastructural Items, Cctv Surveillance System, Epabx And Voice N/W, Audio Visual Solution For The Conference And Training Room At Igr Office, In The Stp-Ii.- 1 Description 2 SITC of IP 4MP IR Bullet Camera (complete with Centralised VMS perpetual license) with Motorized Varifocal lens having minimum technical specification: Image Sensor: 1/2.8” Progressive Scan CMOS; Min. Illumination: Color: 0.01 lux @(F1.2-1.7, AGC ON), 0.01 lux @(F1.2-1.7, AGC ON), 0 lux with IR; Shutter Speed: 1/3 s to 1/100,000 s; Day & Night: IR Cut Filter; 3-Axis Adjustment Pan; Digital Noise Reduction: 3D DNR; WDR: 120dB; Focal length: 2.7 to 13.5 mm; View Angle: Horizontal FOV: 90°, Vertical FOV: 60°; Aperture: F1.2 to F1.7 with Auto focus; Lens Mount: Ø14; IR Range: 50 m or higher; Video Compression Main stream: 3-Line, H.265+/H.265/H.264+/H.264/MJPEG; Video Bit Rate: 128 Kbps to 8 Mbps; Operating Conditions Temperature: -30 °C to +60 °C; Power Supply: 12 VDC, PoE (802.3af); Material: Metal; Protection Level: IP66, IK10, Lightning Protection, Surge Protection and Voltage Transient Protection. REGULATORY: CE, FCC, UL, ONVIF, BIS; Including Centralised VMS Software License & pole Mounting Bracket for Camera (if required as per site). Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 3 SITC of IP 4MP IR Dome Camera (complete with Centralised VMS perpetual license) with Motorized Varifocal lens having minimum technical specification: Image Sensor: 1/2.8” Progressive Scan CMOS; Min. Illumination: Color: 0.01 lux @(F1.2-1.7, AGC ON), 0.01 lux @(F1.2-1.7, AGC ON), 0 lux with IR; Shutter Speed: 1/3 s to 1/100,000 s; Day & Night: IR Cut Filter; 3-Axis Adjustment Pan; Digital Noise Reduction: 3D DNR; WDR: 120dB; Focal length: 2.7 to 13.5 mm; View Angle: Horizontal FOV: 90°, Vertical FOV: 60°; Aperture: F1.2 to F1.7 with Auto focus; Lens Mount: Ø14; IR Range: 50 m or higher; Video Compression Main stream: 3-Line, H.265+/H.265/H.264+/H.264 /MJPEG; Video Bit Rate: 128 Kbps to 8 Mbps; Operating Conditions Temperature: -30 °C to +60 °C; Power Supply: 12 VDC, PoE (802.3af); Material: Metal; Protection Level: IP66, IK10, Lightning Protection, Surge Protection and Voltage Transient Protection. REGULATORY: CE, FCC, UL, ONVIF, BIS; Including Centralised VMS Software License & pole Mounting Bracket for Camera (if required as per site).Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 4 SITC of 16 Channel IP 4K NVR having minimum technical specification: Video Input: 32 Channel IP Fully Featured NVR; Audio Iuput/Output: 1 Channel Input/2 Channel Outputs, RCA; Display Interface: 2 HDMI (1 HDMI up to 3840 × 2160); 2 VGA; Display Split: 1/4/8/9/16/25/36/64; OSD: Camera title; Time; Video loss; Camera lock; Motion detection; Recording; Compression: H.265/H.264/MJPEG/MPEG4; Resolution: 12 MP (4000 × 3000); 8 MP (3840 × 2160); 6 MP (3072 × 2048); 5 MP (2560 × 1920); 4 MP (2560 × 1440); 3 MP (2048 × 1520); 1080p (1920 × 1080); 720p (1280 × 720); D1 (704 × 576 / 704 × 480); CIF (352 × 288 / 352 × 240); Frame Rate: 1–15 fps (12 MP and 8 MP); 1–25/30 fps (rest of the resolutions); Record Bit Rate: 256Mbps or 200Mbps(when RAID is enabled); Bit Rate: 16 kbps ~ 20 Mbps, per channel; Network Throughput: Input 256Mbps or 200Mbps (when RAID is enabled); Output 256Mbps or 200Mbps (when RAID is enabled); Cascading: Built-in CMS to Monitor and Manage Multiple Matrix NVRs; ONVIF and Major Camera Brands Support; Usb Port: 4; RS232: 1 port (for PC communications and keyboard). Temperature: -10 ºC ~ +55 ºC; REGULATORY: CE, FCC, UL, ONVIF, BIS; Including Wireless Bluetooth Multi Device Keyboard and Mouse. Centralised VMS perpetual license.Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 5 SITC of Non-Touch Commercial LED UHD Display (Indoor Type) having minimum technical specification Size (diagonally): 55-inch or higher; Effective Display Area (W x H): as per OEM; Panel Technology: Vertical Alignment, Type: IPS Panel/D- LED/Edge LED, Resolution: 3840 x 2160 pixels @ 50 Hz or higher, Aspect Ratio: 16:9, Colors: 2 Million Colors or higher; Brightness: 350cd/m^2 or nits or higher, Contrast Ratio (Static): 1100:1, Viewing Angle: 178° Vertical / 178° Horizontal Display; Response Time: 8 ms(Typ) or less, Operation Hour: 24Hr x 7; Frequency: 50Hz ± 2% or better, Audio: 20Watt (10W + 10W); Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 6 SITC of Hard Disk .Spec Surveillance Grade HDD of minimum 7200 rpm for storage 8TB storage capacity.Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 7 SITC of: Business Communication System with all necessary power accessories: EPBAX system with line: 4 Trunk, 8 Digital & 48 Line Analog Extensions, Expendable up to 96 Analog Extensions with all necessary power accessories; Other Faetures: Hotline, Live Call Supervision, Auto Call Back, Automatic Call, Disconnector, Auto Redial,Call Splitting, Call Conference, Direct Inward Dialing, External Call Forwarding, Executive/ Secretary etc. 8 SITC of Digital Telephone Set 9 SITC of Analog CLI Telephone Set. 10 SITC of: 5 pair Un-armoured Telephone Cable {0.5mm.Dia (Minimum)} 11 SITC of: 200 Pair MDF with original Krone Module with 20 SWG GI Sheet Steel Box Enclosure complete WITH ALL ACCESSORIES. 12 SITC & Laying of PVC conduits(ISI marked) laying through surface with all accessories as required FOR THE ENTIRE SYSTEM WITH ALL OEM ACCESSORIES. (Quality: MMS; Ø=25mm) Quality : ISI, Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure. 13 SITC of ceiling speaker 2 Way, Acoustic Suspension ceiling mount speakers with superior sound quality. Components: LF: 8cone driver; HF: 1 soft dome; Frequency range (-10dB): 55Hz - 20kHz; Nominal coverage: H x V: 100° conical; Power rating: 180W PGM; Transformer taps: 60W, 30W, 15W @ 100V; Sensitivity (1W; 1m on axis): 90dB SPL; Peak: 116dB SPL; Certificate: CE, RoHS; Color- White. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 14 SITC of Multichannel Power Amplifier Output power : 1kHz (THD +N=1%: 4Ω/8Ω) 140W x 4 , Frequency response : 0dB, ±1.0dB (RL=8Ω, 100V/70V, Po=1W, 20Hz - 20kHz) , S/N ratio : ≥ 100dB(A-weighted) , Crosstalk : ≤ -60dB. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 15 SITC of column array speaker Full-range, Bass reflex type slim line array/ column array speaker with 8 x 1.5” Cone; Frequency range (- 10dB): 81 Hz – 20 kHz; Nominal coverage: H x V: 170° x 25° - 30°; Power rating: 160 W PGM; Sensitivity (1W; 1m on axis): 91 dB SPL; Peak: 116 dB SPL. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 16 SITC of Multichannel Power Amplifier Output power 1kHz Non-clip 20msec Burst Both channels driven 300W x 2 @ 8Ω & 2Ω and 500W @ 4Ω; Sampling frequency rate: 48kHz; A/D D/A Converters: AD/DA: 24-bit linear, 128 times over sampling; THD: 0.1% (1kHz, 10W), 0.3% (1kHz, Half power); Frequency response: ±1.0dB (1W, 8Ω, 20Hz to 20kHz); Input impedance: 20kΩ (Balance), 10kΩ (Unbalance); I/O Connectors: Speaker output: Neutrik speakON NL4 x2, Binding post x2 pairs, 1/4 PHONE(TS) x2; Line Input: XLR-3-31 x2, 1/4 PHONE(TRS) x2; Inbuilt Load protection, Amplifier protection & Power supply protection. 17 SITC of Digital Signal Processor Sampling frequency rate Internal 48kHz/44.1kHz ; Signal delay : 1.9 msec (AD-DA @48kHz), Total harmonic distortion : “0.05% (+4dBu, Gain:-6dB, 48kHz) 0.1% (+4dBu, Gain: +66dB, 48kHz)” (Measured with a 18dB/Oct filter @80kHz) ; YDIF In YDIF RS-422 16IN RJ45 , YDIF Out YDIF RS-422 16OUT RJ45 ; GPI 16IN / 8OUT IN 0V-5V,(IN 16 L(0V-2.5V)/H(2.5V-24V)), Output channel functions : Room Delay, Room EQ, Speaker Processor, X-Over (1way,2way), Delay, 6-band PEQ, Limiter, AEC. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 18 SITC of Digital Control panel 1 Volume & 4 Switch equipped Wall Mounut Control panel for DSP ; Easy connection by CAT5 carrying RS485 + power.Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 19 SITC of Ceiling Microphone Frequency response: 160Hz – 16kHz(- 10dB) or better; Sampling Rate: 48kHz; Bit depth: 24bit; Latency: 60 [ms] (including signal processing) or lower; Audio I/O Dante: 1in x 2out, In1=AEC reference signal/Out1=output of beam mix, Out2= output of beam mix (simple processed); Maximum input level of SPL: 117.8 dB SPL; Self Noise: -0.8 dBA SPL; SNR(Ref. 94 dB SPL at 1 kHz): 94.8 dBA; Sensitivity: -23.8 dBFS/Pa; Dynamic Range: 118.6 dBA; Signal Processing: Multi beam tracking, Adaptive Echo Canceler, Noise Reduction, Dereverberation, Auto Mixer, Auto Gain Control, Parametric EQ, Output Gain; Power requirements: PoE(IEEE 802.3af), DC 48V; Indicator: Front Indicator(Mute/Unmute & Status) ・Network Port Indicator. (Ceiling Mic & DSP Should be from Same OEM) . Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 20 SITC of L2 Switch for stable operation of a Dante network with Standard IEEE 802.3 (10BASE-T/100BASE-TX/1000BASE-T); Number of ports: 10 Ports; Communication mode: Auto negotiation; Connector type: RJ-45; LAN ports: IEEE 802.3 (1000BASE-T) 2 ports; 8 ports (1-8) PoE Power Supply; PoE Standards: IEEE 802.3at; Max power supply per port: 30 W. 21 SITC of FHD 20x PTZ camera 1080p @ 60 frames per second PTZ Camera with minimum 20X Optical Zoom and FoV of minimum 57 deg, min 100 Presets.Camera should support simultaneous outputs through Ethernet, HDMI, 3G-SDI, Audio In and can be controlled via RS232 & 422 In & Out & IP.Panning angle -170° ~ +170°, Tilting angle -30° ~ +90° . The tilting and panning speed of camera should be minimum 300° per second. Camera should support SRT, FreeD Protocol, PoE and Virtual USB Driver. OEM should be CE, FCC, RoHS & BIS Certified. Warranty: 03 (Three) onsite comprehensive OEM warranty with parts and service. 22 SITC of 86 UHD LED Interactive Display 86, 4K Multi touch interactive display, 450 cd/m2 Panel Technology- IPS, ,Android Pie 11.0, 8 GB Memory, 128 GB storage, Built in Wifi & Bluetooth, 2x20 W - Front Facing Speakers, Continuous Touch Points: 40 Points: Windows,10 Points: Android. Rear port terminals: 4 x HDMI IN, 1 x VGA, 2 x USB 2.0 Type A, 1 x USB 2.0 Type C, 1 x Micro SD, 1 x secure slot (USB 2.0), 1 x OPS slot (15W), 1 x HDMI Out, 1 x RJ45. Front Port Terminals: 2 x USB2.0 Type-A, 1 x USB2.0 Type-B for touch, 1 x HDMI2.0 Input, Capability to connect & disconnect all devices / group of devices from central location. Application have capability to share and finish casting of BYOD device and have a robust authorization management. Power off & Reboot devices from central location also control external devices such as USB cameras, Speakers, control brightness & clear cache. Device active trend and deactive displays, Writing, Pen, Palm Eraser, Save, Screen Capture, Storage and Tool Bar. Supports 3rd party applications, recording feature, USB WEB Cam Compatible, Support PPT, Word, PDF, Image, Video Play, 24x7 operation, with OPS i5, 8GB RAM, 256GB SSD. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 23 SITC of 32 HD Display 32 FHD Ready resolution Android LED display Brightness-500 Nits, Operating Hours- 24x7,with built in 2.4 Ghz Wifi, 1 Ghz Built in Quad core processor, 1.5 GB DDR3 RAM, 8 GB Memory, built in Triple Mali 600 MHz GPU, with 2K HDR, Dolby Audio, Built in Wifi and Chromecast, Built in web browser, HDMI CEC, HDMI ARC, , 20W built in speakers, HDMI 2.0 X 3, AV X 1, USB 2.0 X 1, RJ45 X 1, Headphone Out x 1, SPDIF Out x 1 , RS232CX1. 24 SITC of UHD+ 4x4 HDMI Matrix with Audio Output HDMI input and output with 18Gbps (600MHz) 4K UHD support; DVI 1.0 compliant with the use of an HDMI-DVI adaptor; Supports HD resolutions up to 3840x2160@60 Hz (YUV 4:4:4, 8-bit) & 4096x2160@60 Hz (YUV 4:4:4, 8-bit); Supports 16-bit Deep Color up to 1080p60; Input Port: 4 HDMI; Output Port 4 HDMI, 4 Stereo Audio ( 3.5mm ); HDMI Compliance: HDMI 2.0 (DVI 1.0); HDCP Compliance: 2.x; Input Signal Types: 4096x2160p @ 60 8-bit YUV 4:4:4, HDR 10; Output Signal Types: 4096x2160p@60 8-bit YUV 4:4:4, HDR 10. Warranty: 02 (Two) years onsite comprehensive OEM warranty with parts and service. 25 SITC of Wireless Presenter Operating system Windows 10 and higher macOS 11 (BigSur) and higher Android v9 and higher; Video outputs 4K UHD (3840*2160) @ 30Hz. HDMI 1.4b or USB-C DisplayPort 1.2 (only Gen2); USB: 1 X USB-A, 1 X USB-C ClickShare Buttons 2, Desktop & Mobile Native protocols: Airplay, Google Cast, Miracast* Maximum number of simultaneous connections (with Buttons and/or App): 32; Noise Level: Max. 25dBA @ 0-30°C Max. 30dBA @ 30-40°C Authentication protocol WPA2-PSK in stand alone mode WPA2-PSK or IEEE 802.1X, Wireless transmission protocol IEEE 802.11 a/g/n/ac and IEEE 802.15.1; Reach: Adjustable with signal strength modulation; max. 30m (100 ft),Frequency band: 2.4 GHZ and 5 GHz. including 2 additional buttons. 26 SITC of 1.5 sq mm Speaker Wire: 27 SITC of CAT6 Cable: 28 SITC of 15/10/5/2/1 mtr HDMI Cable- as required 29 SITC of AUDIO Cable 30 SITC of 10 mtr USB Cable 31 SITC of 25mm PVC Conduit/Casing/Raceway with accessories 32 SITC of Connectors & Interconnects 33 Mics - installation accessories 34 SITC of Digital Podium with 20 or bigger touch display & gooseneck microphone All-in-one Podium with Podium body made from 1.5mm thick CRCA steel, duly powder coated, with security lock cover for Touch display max size 24 Diagonal. With Keyboard tray housing, Mouse, Drawer for doc cam, space for keeping extra laptop/tablet, Gooseneck mic with switch, W/o Central Controller, 360 degree heavy duty movable castor, Open from Front & Back for easy installation, Adjustable Rack, Ample ventilation.Multimedia Controller with Control out put, Multiple input & switchable output. Warranty: 01 (ONE) years onsite comprehensive OEM warranty with parts and service. 35 SITC of Wall Speaker SITC of Wall Mount Speaker with all necessary accessories, having minimum technical specification: System Type: Full range, Acoustic suspension; Components: 3.5 full range; Frequency Range (-10dB): 130Hz-20kHz; Coverage Angle (Horizontal x Vertical): 150° x 160°; Nominal Impedance: 8Ω; Power Rating: 40W; Sensitivity (1W, 1m): 86dB SPL; Maximum SPL (Caluculated, 1m): 105dB SPL; Connectors: 1x Euroblock (4P) (Input: +/-, Loop Thru:+/-); Material, Finish, Color: Black, White; Accessories: Owners Manual, Retaining knob, Terminal cover screw, Wall / Ceiling mount bracket, Terminal cover. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 36 SITC of Mixer Amplifier Output Power : 120W x 2 (20ms Burst) ; Total harmonic distortion : ≤0.2% (Line in to Speaker out, Half power @1kHz, 3Ω/4Ω/8Ω), ≤0.2% (Line in to Speaker out, Half Power @1kHz, 70V/100V, 120W/200W) ; Crosstalk : ≤ -70dB (MIC/LINE input to other MIC/LINE input) ; Mic/Line Input : Input 1-6: 3.5mm Euroblock (6-pin, balanced) x 3. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 37 SITC of 65 4K display: 65 4K UHD (3840x2160 Ready resolution , Brightness-350 Nits, Operating Hours- 24x7,Built in Android OS LED display with built in 2.4 Ghz Wifi, 1.1 Ghz Built in Quad core processor, 2 GB DDR3 RAM, 16 GB Memory, built in Triple Mali 600 MHz GPU, with 2K HDR, Dolby Audio, Built in Wifi and Chromecast, Built in web browser, HDMI CEC, HDMI ARC, 20W built in speakers, HDMI 2.0 X 3, AV X 1, USB 2.0 X 1, RJ45 X 1, Headphone Out x 1, SPDIF Out x 1 , Haze-28%, RS232CX1. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 38 SITC of 43 4K UHD (3840x2160) Display Supply, Installation, Testing and Commissioning of 43 4K UHD (3840x2160) Ready resolution Built in Android OS LED display with brightness- 500 Nits, Operating Hours 24x7, built in 2.4 Ghz Wifi, 1.1 Ghz Built in Quad core processor, 2 GB DDR3 RAM, 16 GB Memory, built in Triple Mali 600 MHz GPU, with 2K HDR, Dolby Audio, Built in Wifi and Chromecast, Built in web browser, HDMI CEC, HDMI ARC, 20W built in speakers, HDMI 2.0 X 3, AV X 1, USB 2.0 X 1, RJ45 X 1, Headphone Out x 1, SPDIF Out x 1 , RS232CX1, Haze-28%. Warranty: 03 (THREE) years onsite comprehensive OEM warranty with parts and service. 39 SITC of UHD+ 4x4 HDMI Matrix with Audio Output HDMI input and output with 18Gbps (600MHz) 4K UHD support; DVI 1.0 compliant with the use of an HDMI-DVI adaptor; Supports HD resolutions up to 3840x2160@60 Hz (YUV 4:4:4, 8-bit) & 4096x2160@60 Hz (YUV 4:4:4, 8-bit); Supports 16-bit Deep Color up to 1080p60; Input Port: 4 HDMI; Output Port 4 HDMI, 4 Stereo Audio ( 3.5mm ); HDMI Compliance: HDMI 2.0 (DVI 1.0); HDCP Compliance: 2.x; Input Signal Types: 4096x2160p @ 60 8-bit YUV 4:4:4, HDR 10; Output Signal Types: 4096x2160p@60 8-bit YUV 4:4:4, HDR 10. Warranty: 02 (Two) years onsite comprehensive OEM warranty with parts and service. 40 SITC of Wireless Lapel Mic: 24 MHz bandwidth 8 frequency banks with each 12 presets, Mute button for full speech control Synchronization via RF remote channel, High-quality true diversity reception, Pick-up pattern tobe cardioid, Automatic frequency scan feature searches for available frequencies, Frequency response (microphone) 80 - 16000 Hz, Dynamic microphone with Cardioid Dynamic Capsule, Sound pressure level (SPL) 149 dB(SPL) max THD, total harmonic distortion < 1 %, RF output power 10 mW, Transducer principle to be permanently polarised, AF sensitivity 1,5 mV/Pa, Signal-to-noise ratio> 103 dB(A). Warranty: 02 (Two) years onsite comprehensive OEM warranty with parts and service. 41 SITC of Wireless Handheld Mic 24 MHz bandwidth: 8 frequency banks with each 12 presets, Mute button for full speech control Synchronization via RF remote channel, High-quality true diversity reception, Pick-up pattern tobe cardioid, Automatic frequency scan feature searches for available frequencies, Frequency response (microphone) 80 - 16000 Hz, Dynamic microphone with Cardioid Dynamic Capsule, Sound pressure level (SPL) 149 dB(SPL) max THD, total harmonic distortion < 1 %, RF output power 10 mW, Transducer principle to be permanently polarised, AF sensitivity 1,5 mV/Pa, Signal to-noise ratio> 103 dB(A). Warranty: 02 (Two) years onsite comprehensive OEM warranty with parts and service. 42 SITC of Small format PC for Podium with dual HDMI output: 43 SITC of Ceiling/Wall Brackets for Displays 44 SITC of 1.5 sq mm Speaker Cable: 45 SITC of CAT6 Cable: 46 SITC of 15/10/5/2/1 mtr HDMI Cable- as required 47 SITC of AUDIO Cable 48 SITC of 25mm PVC Conduit/Casing/Raceway with accessories 49 SITC of Connectors & Interconnects
Contract Date: May 17, 2026 Contract Value : 57.09 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
17.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
18.
Public Administrative Department #10978093 AOC
Tender For Provision Of Cctv Surveillance System In M&Cw Center (Ayushman Arogya Mandir) Mandawaliin Ward No.200 Under Shahdara (South) Zone.; 1 SITC of 4MP fixed lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better** S/N ratio: >45 dB Lens: 2.8mm fixed Video Compression: H.265 or better** Resolution: (2650x1440) or better** Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 30m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard: IP66 or better** Safety standard: UL N 2 SITC of 4MP fixed lens Dome IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better ** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better ** Lens: 2.8mm fixed Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE, DDNS, IEEE802.1X IR Range: Minimum 25m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL 3 SITC of 16 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or betterNetwork Throughput :160Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 1 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg CentSafety standard: UL 4 SITC of 8TB surveillance HDD 5 SITC of full HD LED Monitor,32 INCHES complying with the following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 300 NITS min.Contrast : 1200 : 1 or betterPower supply : 230v + / - 10%, 50 Hz at site with connectionsand along with all accessories etc. Complete as required. 6 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 7 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required(a)25 mm 8 CABLING WIRING, Supplying and laying of 2x1.5 sq mm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 9 SITCIP65 box(without PoE switches)of dimention 310mmX160mmX140 mm onpole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 nos. 15/16 amp modular switch socket set 10 SITC of 16 port Giga PoE switch, 16(PoE 10/100) + 2(10/100/1000) + 1G SFP Slot long distance switch 11 S&F of suitable size GI boxwith modular plate and coverin front on surface or in recess , includingproviding and fixing 6 pin 5/6 & 15/16 amps modular Socket outlet and 15/16 amps modular switch, connectionetc. as reqd 12 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 13 Online UPS - Input supply: Single Phase, Output Supply :SinglePhaseSupplying, installation, Testing & Commissioning of following capacity at full load(Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shallinclude a Rectifier, inverter, battery bank suitable for 30 minutes back up(Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container)and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall beMicroprocessor based Digital Control,using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturingand inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE.The operating efficiency of the UPS systems shall be >95% at 100%non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input gridshall be< 5% at 100 %load. (The required LCfilters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall besuitable for incoming supplyAC single phase 160-270V 50 Hzand delivering output ACsupply true sine wavesingle phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.. Operating temperature0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Displayfor watt/VA,Amp and Voltage power parametersetc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2,it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be withIGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductorcable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPSshould have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. 3KVA 14 SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.8 U 15 Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd.
Contract Date: May 06, 2026 Contract Value : 2.19 Lakh
Local Bodies No of Bidders 4
19.
Railways #10910841 AOC
Supply Of Supply, Installation, Testing And Commissioning Of A High- Accuracy, Full-Bore Inline Electromagnetic Flow Meter Of 40 Mm Size, Suitable For Effluent Measurement In Effluent Treatment Plant (Etp)Supply, Installation, Testing And Commissioning Of A High- Accuracy, Full-Bore Inline Electromagnetic Flow Meter Of 40 Mm Size, Suitable For Effluent Measurement In Effluent Treatment Plant (Etp),Set Of Items - (1) Supply, Installation, Testing And Commissioning Of A High- Accuracy, Full-Bor E Inline Electromagnetic Flow Meter Of 40 Mm Size, Suitable For Effluent Measurement In Effluent Treatment Plant (Etp), With Ip65- Rated Enclosure, Corrosion-Resistant Wetted Parts Compatible With Treated Effluents, I Ntegral Or Remote Digital Display, 4-20 Ma And Pulse Output, Modbus/Rs485 Communication, Dual Power Su Pply (220V Ac, 50 Hz/ Optional 24 Vdc), And Temperature Range 20 Degree C To 180 Degree C, Including Calibration And Configuration, Complete As Per Manufactures Specification And Direction Of Engineer-In-Cha Rge (Make: Aster/Upc Or Equivalent Approved, Model - Mag - Flow 650 Or Similar) - Qty. - 01 No. (2) Compl Ete Pvc Piping System With 3-Valve Bypass Arrangement, Comprising Two Pvc Ball Valves For Isolation, One Pvc Ball Valve For Bypass, And One Pvc Flow Control Valve, All Connected Through A High-Quality Pvc Header Of Suitable Diameter; Including All Associated Fittings Such As Tees, Crosses, Elbows, Reducers, Sockets, Plugs , Unions, Supports, Clamps, Hangers, Fasteners, And Anchoring Accessories; With Cutting, Chasing, And Restor Ation Of Walls/Floors To Original Condition Where Necessary; Scope Also Includes Supply And Installation Of Ele Ctrical Starter (As Per Equipment Rating), Along With Required Control Cabling, Terminations, And Interfacing, All Executed As Per Ga Drawing Approved By Rly. Authority., Qty. - 01 Lot. Detail Technical Specification As P Er Annexure Attached. [ Warranty Period: 30 Months After The Date Of Delivery ] ]
Contract Date: Apr 30, 2026 Contract Value : 1.26 Lakh
Government Departments No of Bidders 1
20.
Drinking Water Supply and Sanitation #10896284 Price Bid
Tender for N.S. Item , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 2700 Lpm X 50.00 M (For B/Stn. No.12) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 6900 Lpm X 45.00 M (For B/Stn. No.14) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 4100 Lpm X 45.00 M (For B/Stn. No.16) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 3500 Lpm X 45.00 M (For B/Stn. No.25) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (10 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (50 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (70 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (95 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (120 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (150 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (185 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (240 Sqmm Size) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.12) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 115 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.14) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 70 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.16) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 5 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.18) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 5 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.19) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 5 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.20) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 60 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.25) , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. (35 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (70 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (95 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (150 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (240 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (300 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (400 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (500 Sqmm Size) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 35 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.22) , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 350 Mm Nominal Diameter , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 2800 Lpm X 50.00 M (At Mbs For Zone -2) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 40 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs For Zone-1) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 55 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs For Zone-2) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 6900 Lpm X 50.00 M (For B/Stn. No.10) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 130 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.10) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 9500 Lpm X 45.00 M (For B/Stn. No.13) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 160 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.13) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 5900 Lpm X 45.00 M (For B/Stn. No.17) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 100 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.17) , Providing And Fixing Of Ci Sluice Valves Conform To Is1 4846 / Din 3352,With Length Over Flanges As Per Pdoralt1ofis14846 Corresponding To Bsen - 558/Iso5752 Basic Series 3 And15 Respectively Including Labour, Material, Joints. Make:Ivc / Vag / Kirloskar Complete In All Respect As Per Specifications Mentioned In Dnit (700 Mm I/D) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 10 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.15) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 120 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At B/Stn. No.13 For Existing Pumping Machinery) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 5100 Lpm X 50.00 M (At Mbs-1 Zone) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 95 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs-1 Zone) , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 100 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 150 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 200 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 250 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 350 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 400 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 450 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 500 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 600 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 700 Mm Nominal Diameter , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8500 Lpm X 35.00 M (At Mbs-1 For B/Stn.) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 112.50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs-1 For B/Stn.) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 5500 Lpm X 30.00 M (At Mbs For B/Stn.) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 62.50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs For B/Stn.) , Supply Erection Testing Of Reputed Make Led Light 100 Wats With Fittings And Accessories Complete In All Respects. (Led= 5 No.) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 6000 Lpm X 50.00 M (For B/Stn. No.9) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 115 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.9) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 4600 Lpm X 45.00 M (For B/Stn. No.23) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 77.50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.23) , Less Credit For Old Good Bricks 20.77 X 60% = 12.46 @ 480 Brick Per Cum = 5981 , Less Credit For Old Bricks Bats @ 40% ( Cum ) Total 20.77 X 40% = 8.31 , Less Credit For Ms Railing @ 40% ( Cum ) Total 11 X 50 = 550 Kg , Providing And Fixing Of 15 Mm Nominal Diameter Water Meter As Per Is 779:1994 Inferential Type Dry Dial, Mechanical Driven, Non Megnatic Drive, Straight Reading Cyclometer Type, 7-Inline Consequent Digits With One Centre Point For Easy Reading Complete In All Respect. , (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). (1 For B/Stn. No.9 , 1 For B/Stn. No.10 , 1 For B/Stn. No.11 , 1 For B/Stn. No.12 , 1 For B/Stn. No.14 , 1 For B/Stn. No.16 , 1 For B/Stn. No.17 , 1 For B/Stn. No.21 , 1 For B/Stn. No.22 , 1 For B/Stn. No.23 , 1 For B/Stn. No.25 , 1 For Mbs-1 , 1 For Mbs-2) , Operation And Maintenance For Complete Scope Of Work Mentioned In Dnit (Disinfection Material Will Be Supplied By Phed) As Per Schedule-Iv For A Period Of 5 Year After 12 MonthS During Defect Liability Period And 3 Months Trial Run Period Will Be Charged To The annual maintenance Estimate Complete In All Respect As Per Approved Nit. (I) Operation And Maintenance Defect Liability Period (Operation Only) After 3 Months Trial Run Period. , (Ii) Operation And Maintenance During 1St Year After Defect Liability Period. , (Iii) Operation And Maintenance During 2Nd Year. , (Iv) Operation And Maintenance During 3Rd Year. , (V) Operation And Maintenance During 4Th Year. , (V) Operation And Maintenance During 5Th Year. , Item Description , Hsr Item
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
21.
New and Renewable Energy #10888928 AOC
Bids Are Invited For Ffd1 Aac Input Fuse Fail Detector Circuit, Mt 111, 415V12v Dc , Con101 A 3 Pole Ac Input Mains Contactor, Mnx 70 Cs97076booo,63A,230V Ac70a , Tr2a Control Transformerclass B Insulation With Temperature Rise Class A 415240V Ac, 500Va , Converter 1A,2A Ac To Dc Converter,Lrs 100 48 , Ip230vac, Op 48V Dc2.3A , Tr1a Three Phase, Double Wound, Impregnated Naturally Air Cooled, Mains Transformer Class H Insulation And Temperature Rise Limited To Class F, Input Power Transformer,32.15 Kva, 45670V, 70V , Ipt 1Ainter Phase Transformer,0.65Kva , Ffd2a 3A, Rectifier Fuse Fail Detector Circuit Modified For Latching Facility Using One Extra Relay And Pb Mounted On Same Pcb Card Used For Trip Function, Mt 111,70V Ac, Aux. Supply 12V Dc , Mr1a 2A3 Phase, Full Controlled, Full Wave Rectifier Bridge Comprising Of Scr With Heat Sink And Surge Suppression Networkt250e160,Scr170a1600 Piv, 250A1600 Piv , Df A Free Wheeling Diode,150Nd160,150A1600piv , Ffd5a Free Wheeling Diode Fuse Fail Detector Circuit Modified For Latching Facility Using One Extra Relayand Pb Mounted On Same Pcb. Card Used For Trip Functionmt 111,48V Ac, Aux Supply 12V Dc , Rc Pcb,Mt 116 , Ch1a, Filter Chokedc Choke , 48325A , Ffd 4A, Filter Capacitor Fuse Fail Detector Circuit Modified For Latching Facility Using One Extra Relayand Pb Mounted On Same Pcb. Card Used For Trip Functionmt 111,48V Ac, Aux Supply 12V Dc , Cpc1a 2A,3 Phase Full Controlled Card With Green Connector6 Pulse ,Mt 103,48Vcv Cc , Hvandpfpsr Card 1A 2A,High Voltage And Phase Failphase Reversal Circuit With Control Transformer 456V18 0 18V, 50Va,Mt 105,415V Ac , Dc Ov 1A,Charger Dc Over Voltage Circuit Of Solid State Sensing Type With External Rl Card Including 1K Ohm50w Resistor,Mt 106 Actuating Voltage 54.5V , Resettingvoltage53v , Dc Ov 2A,Charger Dc Over Voltage Circuit Of Solid State Sensing Type With External Rl Card Including 1K Ohm50w Resistor,Mt 106 Actuating Voltage66.5V ,Resettingvoltage 65V , Mr3a,Charger Silicon Blocker Diode2nos. In Parallel ,250Ng160,250A1600 Piv , Cb 901A3 Pole Moulded Case Circuit Breakermccbfor Dc Output Including Aux Switch For Cb901a And Shunt Trip Coil Du400ncm98402ooro ,400A, 15Ka 50Ka ,Suitable Range 0.81 , Clc 1Abattery Current Limiting Circuitmt 110,240V Ac, Act 45A , Load On Batt1a,Battery Current Sensing Circuit For Battery On Load Alarmmt 110,12 V Dc, Act 8A - Load On Batt1a,Battery Current Sensing Circuit For Battery On Load Alarmmt 110,+12 V Dc, Act 8A , Load On Batt2a,Battery Current Sensing Circuit For Battery On Load Trip Function,Mt 156, 12 V Dc, Act 10A - Load On Batt2a,Battery Current Sensing Circuit For Battery On Load Trip Function,Mt 156,+12 V Dc, Act 10A , 12V Ps 3 4A12v Power Supply For 12V Control Supplyurb4812ld 30Wr3a4s,Ip 18 75Vdc Op 12Vdc2500ma , Mcu1001a1 1A,Monitoring And Controlling Unitmcu ,20 80V Dc , Annunciator 1A,12 Window Annunciator With Labels,Ae48260vacdcdw04sw08rs485,Aux. Sup 48V Dc ,With Rs485 Output , Batt Uv 1Abattery Under Voltage Circuit Of Solid State Sensing Type Including 1 K Ohm 50W Resistor ,Mt 106 Actuating Voltage43.7 V,Resettingvoltage 45 V , 24V Ps 1C 2C,24V Power Supply For Con 901 902Of Standby Charger ,Lrs 150 24,24V Dc , Con 901, 901N, 1 Pole Dc Contactor With 1 No Aux.Evd400g1da4 ,400A, 12 36 V Dc Coil , Ol 1A, Thermal Over Load Relay For Contactor, Range 30 50Amnx 50 Ss94136oogo Mn5 Total Quantity : 79
Contract Date: Ref. Documents Contract Value : 13.48 Lakh
Government Departments No of Bidders 1
23.
Defence #10861312 AOC
Tender For Repair/ Maintenance Of Ht Cables, Switch Gears And Relays Incl Connected Items Under Ge (W) Colaba.; 1 Material and labour of Opening the bus -bar chamber,CT chamber, PT Chamber and Meter chamberof HT 11KV, panel boardand carry out following activities as mentioned below complete all as directed and specified by Engineer-in-Charge.(Note: spare parts shall be measured & paid seperately.) :-(i) Inspecting/cleaning/overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner/Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX(A), STRIPPEX(B)and HTtape and test with High Voltage(DC)and meggering before and after high voltage test complete.(ii) Inspecting/cleaning/overhauling of CT/PT chamberby checking of Bus bars, spout insulators, space heaters and checking of wiring system and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying anti tracking paint on CTs and insulatorsand HT Tape.(iii) Inspecting/cleaning/overhauling meteringchamberby checking ofentire wiring system, all meters, selector switches, control fuses and removing dustwith vacuum cleaner/blower and moisture by hot air blower and checking tightness of wiring system. 2 Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 3 Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare partssuitable for - VCB 11 KV , 630/800 Amps indoor type of Make Schnieder(PIX -MV)/ABB(VD4) /CG/AREVA(VMX) all as specified and directed by Engineer-in-Charge. 4 Isolating Contacts flat type 5 Vaccum InterupterVG2 6 Insulating Rod 7 Closing coil 110V /24V DC 8 Tripping Coil 110V /24V DC 9 Spring Charging Motor 110V-230V AC/DC 10 Breaker Auxiliary Switch 6NO +6NC 11 Motor Cut-off switch 12 Main Drive Shaft assembly 13 Trip Fork Linkage Assembly 14 Rachet Wheel 15 Pin for Rachet 16 Handle Block Assembly 17 Closing coilassembly without coil 18 Trip coilassembly without coil 19 Motor cutt offLever assembly 20 Trip Proper support assembly 21 Release lever 22 Pin for Release lever 23 Auxiary switch drive Assembly 24 Charging Pawl 25 Buffer for Spring 26 Over Rid Stop 27 Over Rid Stop Pin 28 24 Pin Plu and Socket Assembly 29 Bus Bar Spout Insulator with CC parts for R Phase 30 Bus Bar Spout Insulator with CCparts for Y Phase 31 Bus Bar Spout Insulator with CC parts for B Phase 32 Circuit Spout Insulator with CC Parts 33 3Phase Spout Insulator assembly Bus bar /Circuit side. 34 Half Collar (Pair) 35 Raising and lowering Handle 36 TNC Switch,16Amps Recom 37 Ammeter,digital type,DM3110 Schneider 38 Voltmeter,digital type DM3210 Schneider 39 Multifunction meter digital typeEM6400NG Schneider 40 Indicating Lamps 24/110V DC LED type 41 Dismantling, overhauling and testing Potential transformer capacity 11 KV / 110 volts ACand replacement of worn out spares such as contacts, bushing, control wiring fibre plates, gaskets , transformer oil and applying multi grease to the mechenical parts & dry graphite conductive sealant to contacts etc & re-assembling the same and commissioning complete all as specified and directed by Engineer-in-Charge. (Note : Spare parts and oil will be measured and paid seperately) 42 Material and labour for painting of HT VCBcapacity 250/350MVA,11KV, 400/630/800Amps, with onecoat of synthetic enamel paint over a coat ofred oxide primerafter cleaning, scraping, and filling ofcavitiesfor out side surface and in side surfaceof VCB and writing the details such as MES No/ SM No etc on the new metallic plate of size 30x15cm and fixng the metallic plate firmy on VCBall as specified and as directed by Engineer-in-charge. 43 S&F, testing commissioning ofcurrent transformer 50-30,5+5Amps, Class1 and 5p10,15VA,18.3kA/3Sec for 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps, panel board complete all as directed and specified by Engineer-in-Charge. 44 T&P for Testing of primary injection by artificialloadthroughCT’s, on each multiple settingofovercurrent & earth fault relay, testing polarities, ammeter and selectorswitchandasdirected by Engineer-in-Charge. 45 T&P for Testing /Overhauling and secondary injection of over current earth fault relays/release on each multiple setting readjustment by artificial load complete all as specified including testing complete. 46 Repair/Overhauling Indoor type, 11 KV, SF 6, RMU Panel and carrying with following and all as specified and directed by engineer in Charge.Note :- (i) Including fixing ofspare parts to function RMU smoothly and rate to be included.Notes :-Spare parts and SF6 Gas will be measured and paid separatly. (i) Inspecting/overhauling of Manual/motorised spring drive mechanism by checking mechanism, Motor and gear assembly, Big gear assembly, stop bolt assembly, Main shaft interlocking assembly, closing spring assembly, Small Cam with screw, motor cut -off limit switch, Butter fly switch assembly and apply multi grease lubricant to function smoothly.(ii)Inspecting / overhauling of assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii)Inspecting / overhauling /cleaning and inspecting insulators, Gas Chamber by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Inspecting of Gas SF6 leakage and Re filling SF6 gas as required and all as directed.(v) Overhauling/testing of Metering Panel with PT(vi) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete.(vii) Cleaning all busbar by rubbing and by CRC liquid cleaner.(viii)Spraying two coat of anti track paint on CTs.(ix) Applying insulating boots for busbar and cables. (x) Supply and fixing all missing nut bolts for panels. 47 S&F 11 KV, SF 6,RMU Panel Spring Charging Motor, with complete mechanisim 230/110/24 Volts of existing make. 48 S&F 11 KV, SF 6,RMU Panel SF 6 Gas filling up to the indication mark complete all as specified and as directed. 49 Repair/ MaintenanceBattery Charger Circuit 240 V AC to110 V DC 20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed. 50 Repair/ MaintenanceDC to DC Converter 110 V DC to 24 Volt dc20 A (with range from 10A to 20A) with inbuilt short circuit protection supply for control circuit of 11 KV VCB/RMU complete incliuding replacement of defective parts all as specified and as directed 51 S&F battery SMF EP 100-12 (12V/100AH) complete all as specified and as directed 52 Dismantling old burnt Heaters and Supply Fixing Space Heater 80 Watt capacitysuitable for VCB,s /OCB in existing panel including hard ware,wiringand all as directed. 53 T&P for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 54 T&P for route tracing ofHT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge. 55 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 56 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240 sqmm to 300 sqmm all as specified. 57 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 120 sqmm to 185 sqmm all as specified. 58 Supply and fix cable jointing kit for 11 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumunium conductor cable of size 240sqmm to 300 sqmm all as specified. 59 Supply, Installation, testing ON LOAD & commissioning of Compact motor protection relay flush mounting with display MM-10 with 110-240V AC/DC aux supply, having following protections with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system making good to the disturbed surface all as specified and directed.(a) Thermal over load and short circuit . (b) Earth fault and phase loss, unbalance, phase reversal.(c) Prolong starting, locked rotor and last trip data recording. 60 Supply, Installation, testing & commissioning of Under Over Voltage relay single phase system voltage 20-110 Volt AC/DC with required mechanical cutout arrangement & required control wiring modification work to suitable new relay to existing system including making to the disturbed surface all as specified and directed. 61 Material and labour for loading into truck of old OCB/VCB with the help of Crain and shifting from site to store/ substation premises and unloading complete all as specified and directed. 62 Material and labour Disconnecting, dismantling & restablising the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350MVA, 400/630/800 Amps from location and repair /overhaulingand carrying out with the followingactivities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare partswill be measured & paid seperately.) (i) Inspecting / overhaulingof manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly.(ii) Inspecting / overhauling oftripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system.(iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptorsby carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces.(iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC)and meggering before and after high voltage test complete. 63 Excavating in trenches, n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out completein soft/loose soil all as specified. 64 All as perabove item No.63.00 above but in hard/dense soil. 65 Excavationin trenches not exc. 1.5 m wide and not exc. 1.5 in depth for foundation of poles, stay assembly and laying of U/G cables etc. and getting out in soft disintegrated rocks/road cutting/RCC/PCC complete all as specified and directed. 66 Supply and providing sand/stone dust for sand cushioning for cable protection orfilling in trenches of sand in cable ducts after cleaning of ducts all as directed and specified Note:. for the purpose of payment punned thicknesswill be measured. 67 Supply and providingunreinforced pre cast cement concrete cable cover for cable protection (Ready made Covers) ofsizes Class HVPtype I with peak, flat size 300x180x40 mm putting adjecent to each other as specified. 68 Supply and laying tubes light grade, galvanized, 100 mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable all as directed. 69 Returning,filling in soft/loose soil including spreading, levelling, watering ,well ramming in layers n.exc 25 cm complete all as specified. 70 Removing of excavated material not exc. 50m away from starting point and depositing where directed at a level not exc. 1.5m above the starting point.in soft /loose soil 71 Removing of excavated material from the site of work and transporting out of MD land complete all as specified and directed. 72 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 240 sq. mm X 3 core all as specified and as directed. 73 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq. mm X 3 core all as specified and as directed. 74 Supply,laying in trench, in duct on wall,and testing in replacement forXLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sq. mm X 3 core all as specified and as directed. 75 Manufacturing, supplying and fixing at various sub stations for SOP (Standard Operating Procedure) for VCB/ RMU Operation on farme board of size 600 mm x 900mm having fully covered by suitable plain glass as approved . Letter,symbols, MES Logo ,borders etc.on A-1 Size paper all as required colour scheme in all respects as per direction of Engineer-in-charge. 76 T&P for fault finding, confirmation and route tracing on LT cables of any size and any length with fault detective machine by thumping method and suitable high voltage and all as and directed by Engineer-in-charge. 77 Material & labour for cable jointing kit, in repair, for LT 1.1 KV grade cable for straight through joint M-Seal type for underground PVC/XLPE armoured heavy duty cable aluminum conductor of size3.5/4 core 50 Sqmmcomplete including testing & commissioning complete all as specified and directed. Make: XICON/Raychem/3M/Mahindra and Mahindra. 78 All as per aboveitem No 77.00 herein before but cable 3.5 core 70 Sq mm 79 All as per aboveitem No 77.00 herein before but cable 3.5 core 95 Sq mm 80 All as per aboveitem No 77.00 herein before but cable 3.5 core 120 Sq mm 81 All as per aboveitem No 77.00 herein before but cable 3.5 core 185 Sq mm 82 All as per aboveitem No 77.00 herein before but cable 3.5 core 240 Sq mm 83 Material & Labourfor repairs/ Overhauling/Servicing to ExistingLT electric panels by takingshut down from appropiate authority includingT&P for Attending Faults/Trippings and rectifieng /repairingthe faults in HT/LT Panels Boards/Capacitor Panels Boaeds/ MCCBs/ACBs /Change Over switches/Cable Connections/Bus Bar etc including PVC insulating Tapes/Nut boltsand all as specified and directed by Engineer-In-Charge. (i)Tightning the loose connectionsand cleaning inside/out side complete replacing all cable glands,thimbles and lugs as per the size of existing cable, applying petrolium jelly on the contactors ,providing new insulation tape to bus bars, repair to broken /hanging doors by fixing hinges or welding the door to make it servicable, spray painting as pproved colourandtesting the entire panel board after the completion of servicing up to the satisfication of Engr-in-charge complete all as specified and directed .(Note : MCCB,ACB, measured and paidseparately under relevant items of this schedule.) 84 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 240 Sqmm to 300 Sqmm x 3.5 core complete all as specified and directed by Engr-in-charge. 85 Dismantling of Damaged/Burnt out lugs and Supply & fixing of Aluminum Lugs with PVC Insulation Tape of size 120Sqmm to 240Sqmm x 3.5 corecomplete all as specified and directed by Engr-in-charge. 86 Dismantling Air Circuit Breaker 4pole/3pole, 630Amps to 1200Amps, 415 Volts, draw out/fixed type from location and repair /overhaulingof spring drive mechanism, coil, auxiliary switch includingsetting of over loadcoil, no volt coil, tripping coil & apply multi grease for mechnical parts, cleaning and inspectingmale and female contacts and apply dry graphite conductive sealant for contacts, checking of electrical wiring system, testing, and assembling all items/components parts to the respective positionandtesting complete all as specified and directed by Engineer-in-Charge. 87 Dismantling of Old Damaged/burnt spare parts from ACB and Supply and fixing in repair of following Spare partssuitable for -ACB 415V , 630 to 1200Amps Amps indoor type of Make ; Havells/ Schneider/IndoAsian/HPL/Legrand/C&S all as specified and directed by Engineer-in-Charge. 88 Shunt Trip Device 89 Closing coil assembly 90 Mismatch Prevention Device 91 Moving contacts assembly 92 Fixed Contact assembly 93 Auxiliary Switch 94 Arc chut with hardware 95 Current Transformers 630A/5A. 96 Current Transformers 800A/5A 97 Current Transformers 1200A/5A 98 Dismantlingof old damaged Meters and Supply & fixDigital LT voltmeter with selector switch of size 96x 96mm rating 0 to 500 volt all as specified and directed. Make:AE/MECO/ Elmeasure. 99 Dismantlingof old damaged MetersSupply & fixing Digital LT Ammeter with selector switch of size 96x 96mm suitable for CT ratio 5amp, programmable type andall as specified and directed. Make:AE/MECO/ Elmeasure. 100 Dismantling of old damaged halogen fitting Supply & fixing in repairs 500 watt Incandescent/ GLS lamp halogen Lamps with holder with aluminum cover 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 101 S&F of Room Heater 1000 Watt coil type in substation to avoid moisture in HT installation room complete all as specified and directed by Engr-in-charge. 102 Dismantling of old damaged Lamps and Supply & fixing in repairs 200 watt Incandescent/ GLS lamp 230Volts AC for substation heating to avoid moisture completeall as specified and directed.Make:Wipro/ Surya, crompton 103 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel as required for retrofit after wiring work complete all as specified & directed. 104 M&L for Maint of Multi functional meter digital type 5000 LCD CI with RS485 including necessary alteration in existing panel,SMARTCOMN EMS Energy Management System software with multiple features suitable for minimum 10 meters at existing dashboard/ computer and shall capture and provide following data for 12 months peroid:1) 30 min instantaneous data from all the meters for seven parameters- cumulative Energy, Power, Current, Voltage, Power factor and frequency. 2) Multiple combination of device and parameters for analysis and monthly and quaterly billing survey dattion a for cumulative energy and max demand.3) Specific Energy Consumption (SEC) Report and assess to features defined by user levels.4) Monitor ON, OFF, TRIP, Ready to close status of circuit breaker through E&As UNCO Module with on premise solution. 5) Provision for Breaker ON & TRIP counter, Last 20 trips date & time6) Email and SMS notification & Excel reports with charts. 105 M&L for Maint of MQTT GPRS Converter Outdoor (LoRa) Long Range Communication Accumulator suitable for communicating with multifunctional digital Meter with LoRa communication protocol and the data transfer to the software complete all as required on existing ground position as specified and directed. 106 M&L for Maintand recharge topup for 12 months peroidof 4G/5G Router all asrequired as on existing ground position including necessary data cable (low impedance ) suitable to existing ground position including necessary data cable (low impedance) suitable to transmit data of energy meter port and CAT-6 (Patch Cord) all as directed by Engr-in-Charge. 107 M & L and fabrication work with Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specifeid and diredted by Engr-in-charge. 108 M&L electrical earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6 mm thick burried directly inground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level, connected toGI earth strip 32mm x 6mmearth leadby means of bolts,nuts and washers of galvanised iron, earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board/panel board , all as specified and shown in MES schedule Electrical Plate No-5 of SSR Part I, including excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, RCC 1:2:4 type B1, 40 mm thick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways, with 6 mm dia MS hook, Charcoaldust, salt, funnel for watering complete and testing the Earth resistence and writing on the chamber by paint all as specified and as directed. Note : Value of earth resistance shall not be more than 2 Ohm. 109 M&L in repairs galvanised iron strip 32x6mm earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles in roof ofhigh rise bldg and as required by saddles not more than distatance of 50 cm between two saddles with jointing nuts, bolts /washers to wall/surface or recess of high rised buildings or burried in ground or any situation for loop all as specified and directed by the Engineer-in-Charge. 110 Supply and fixing substation insulation rubber floor mats not less than 2.5 mm thickness suitable for operation on 11 KV panels confirming to IS 15652 : 2006 all as specified and directed by Engineer-Incharge.
Contract Date: Apr 27, 2026 Contract Value : 32.04 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
24.
Defence #10845268 AOC
Tender For Renewal Replacement Of Furniture Against Surveyed Furniture Items At Naval Station Karanja; 1 Supply, Installation and testing of VPN Firewall (Sophos) with 1 year enterprise Guard License with Ethernet interfaces (fixed)-4GbE copper , I/O ports-2 x USB 2.0,1 x Micro-USB, 1 x COM (RJ45) with COMPUTER including monitor of 32 inch (4K) having the following specifications: (a) Processor: INTEL i7 processor, (b) RAM 16 GB RAM, (c) Hard Disk: 1TB, (d) Keyboard and Mouse (e) LAN port (f) Inbuilt software: Anti virus softwareand Windows 11 or better (g) All SCADA System related softwares like FT View, KEP Server SQL Management Studio etc all as directed by Engineer-in-Charge. Make: DELL, HP, Samsung, Lenovo 2 Supply, Installation and testing of new PLC , Digital Inputs, Digital Outputs, Analog Inputs, Serial Communication RS232/ RS485 x 1, Ethernet Port x 1 and re-wiring of the exisiting panel with respect to the required Inputs & Outputs including dismantling of unserviceable PLC complete .Make: Mitsubishi/ Delta/ Honeywell. 3 Supply, Installation,testing and Comissioning of GPRS Modem Dual SIM redundancy for persistent 2G/3G/4G cellular network connections having features of IP sec/Open VPN /GRE /L2TP/PPTP/DMVPN with 1 Ethernet Port, 1 RS232/RS485 Port complete all as specified. Make: Robustel, Maestro, Teltonika 4 S&F for PVC insulated and sheathed armoured copper cable of size 1.5 Sqmm 4 core fixedon wall/ RCC tank/surface etc complete all as specified and directed by Engr-in charge . Make: Polycab / KEI / Havells. 5 Supply, Installation, testing and comissioning of factory talk view SE station license for local (single station) applications where all components run on one computer. Applications can be configured to local or to work with other factory talk products like factory talk historian SE, networked scope including supply, Installation, testing and comissioning of OPC server for unlimited tags with MODBUSTCP/equivalent driver having provision for IOT gateway to exchange data between the PLC based panels and the system complete all specified.Make: Rockwell Automation/CIMCON/SCHNEIDER ELECTRIC. 6 Programming, Comissioningand testing(On-Site) of the existing PLC based automation panels, OPC tags creation, tags creation for new panels, screen development, Object linking, tag linking with OPC, data validation on SCADA server as per the instructions of Engineer-in-Charge. 7 Supply, Installation, testing and comissining of Ultrasonic Level Sensor range from 0 to 8 meters all as specified and directed by Engineer-in-Charge.Make: Banner/ SIEMENS/ ENDRESS HAUSER. 8 S&F in replacement ofCast iron Butterfly valve along with actuator assembly complete of size 200 mm dia, PN 10 with stainless steel shaft, operating angle 90° complete all as specified and directed by Engineer-in-Charge. Make: ZOLOTO/ Kirloskar/ Venus/L&T. 9 S&F in replacement ofCast iron Butterfly valve along with actuator assembly complete of size 150 mm dia, PN 10 with stainless steel shaft, operating angle 90° complete all as specified and directed by Engineer-in-Charge. Make: ZOLOTO/ Kirloskar/ Venus/L&T. 10 S&F in replacement of hand wheel for actuator suitable for 100 to 200 mm dia butterfly Valve . Make : Ritetork/ Emtork/Venus/L&T
Contract Date: May 05, 2026 Contract Value : 15.35 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
25.
Power #10777958 Price Bid
Supply of Electrical Items and Stores Hardware Items for Sub-Transmission Division-II, JPDCL, Jammmu for the year 2025-26 33 Kv & 11 Kv Cable Kits Indoor/Outdoor (Make Hot Set Or Any Other Reputed Make Conforming To Relevant Is Specifications) Raychem, 3M, Densen Or Equivalent A) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , B) Cable Kits 33 Kv Single Core Heat Shrinkable Indoor 300 Mm2 , C) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , D) Cable Kits 33 Kv Single Core Heat Shrinkable Outdoor 300 Mm2 , E) Cable Kits 11 Kv Single Core Heat Shrinkable Indoor 630 Mm2 , F) Cable Kits 11 Kv Single Core Heat Shrinkable Outdoor 630 Mm2 , G) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 400 Mm2 , H) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 300 Mm2 , I) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 240 Mm2 , J) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 185 Mm2 , K) Cable Kits 11 Kv 3 Core Heat Shrinkable Indoor 120 Mm2 , L) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 400 Mm2 , M) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 300 Mm2 , N) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 240 Mm2 , O) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 185 Mm2 , P) Cable Kits 11 Kv 3 Core Heat Shrinkable Outdoor 120 Mm2 , Q) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 185 Mm2 , R) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 300 Mm2 , S) Cable Kits 11 Kv 3 Core Straight Through Joining, Heat Shrinkable 400 Mm2 , T) Cable Kits 11 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , U) Cable Kits 33 Kv Single Core Straight Through Joining, Heat Shrinkable 630 Mm2 , 33 Kv, 3Cx400 Sq Mm , Touch Proof Kit, Screen Separable Elbow Terminationconnector/Kit, Confirming To En 50180/En 50181 (Raychem/Denson/3M) , 33 Kv 3Cx400 Sq Mm Xlpe Aluminium Power Cable , Spares For 33 Kv C&R Panels And 11 Kv Vcb/Ocb Panel Banks.A) Inner Baffle For 33 Kv Mocb Bhel , C) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bhel Make , D) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Bicco Lawrie Make , E) Grid Spout Assembly Suitable For 11 Kv Ocb Panel Crompton Greaves Make , F) Trolly Copper Bushing Rod Suitable For11 Kv Ocb Panel Ssg Make (Parma Wood)/Crompton Greaves Make , G) Male Contact For 11 Kv Ocbbicco Lawrie Make (Copper) With Silver Coating 11 Ocb Panel , H) Male Contact For 11 Kv Ocb S.S.G Make (Top Tip Of Iron) With Silver Coating , I) Male Contact For 11 Kv Ocbcrompton Greaves Make (With Silver Coating) , J) Male Contact For 11 Kv Ocbbhel Make(With Silver Coating) , J) Male Contact For Ocbmei Make (With Silver Coating) , K) Female Contact For 11 Kvocb Bicco Lawrie Make (With Silver Coating) , L) Female Contact For 11 Kv Ocb S.S.G Make (With Silver Coating) , M) Female Contact For 11 Kvocb Cromption Greaves Make (With Silver Coating) , N) Female Contact For 11 Kv Ocb Bhel Make (With Silver Coating) , O) Trip Bridge Assembly (Bl) , P) Roller Assembly (Bl) , Q) Female Contact For 11 Kv Ocb Mei Make (With Silver Coating) , R) 11 Kv Pt Fuse , S) 11 Kv Vcb Bottle Assembly Bracket , T) Shower Contact Mei Make , U) Shower Contact Crompton Greaves Make , V) Arc Pot Mei Make , W) Tripping Coil Suitable For 33 Kv And 11 Kv Ocb / Vcb Panels (Operating Voltage 30-36 Volt Dc) , X) Tripping Coil For 66 Kv Ocb / Vcb Panels , Ammeter Selector Switches , Voltage Selector Switches , Multifunction Transducer, Rish Master 3450 Model, Class 0.2S, Input: 3Ph, 100-600V L-L, 5A/1A, 45….65 Hz, With Rs485 Output, Aux Voltage: 12…60V Ac/Dc , Contact Multiplying Relay, Salzer, Mkp 2P 30S, Coil Voltage : 30 V Dc , Master Trip Relay, Alstom Make, Mvajm15ja0204a Model, 30-34 V Dc , Master Trip Relay, Abb Make, Pq8nch2js Model, 30V Dc , Master Trip Relay, Ashida Make, Avajh13-Am-011-03-01-6-00-00-00, 4 No + 1Nc Hr Model, 24/30V Dc , Micom Alstom Relay ( For 11 Kv Panels), Model: P14nb16a6c0610a , Ref615, Abb Make Feeder Protection Relay, Product Order Code: Hbfnaeagnda1baa21g ( For 11 Kv Cr Panels) , Ret615, Abb Make Differential Complete Relay ,Product Order Code: Hbtdbabanda1ann21g ( For 33 Kv Cr Panels) , Control Card For Ret615 Abb Relay , Bio0005 2Rca025501a0001e 2Rca024987d , Power Card For Ret 615 Abb Relay, Psm0903 2Rca025058a0901p 2Rca024584m , Space Heaters, 230 V Ac, 200W , Thermostat: 230 V Ac, 5-60 Deg Celcius , 11 Kv Cts Of Different Ratios, Make Mei/ Bicco Lawrie / Crompton Greaves / Bhel/ Er/ Ssg/ Alstorm/ Megawin/ Sudhir/Electricfield For 11 Kv Ocb/ Vcb Panels I) 800/400/5-5 , Ii)750/375/5-5-5 , Iii)600/300/5-5-5 , Iv)600/300/5-5-5 , V)400/200/5-5 , Vi) 300/150/5-5 , Vii)150/75/5-5 , Spares For Power Transformers A) Breather For 6.3 Mva 33/11 Kv Transformer (2 Kg) , B) Breather For 10 Mva 33/11 Kv Transformer (3 Kg) , C) Breather For 5 Mva 33/11 Kv Transformer (2 Kg) , C) Breather For 5 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 6.3 Mva 66/11 Kv Transformer (3 Kg) , C) Breather For 10 Mva 66/11 Kv Transformer (3 Kg) , D) 20 Mm Lt Bush Rod For 33/11 Kv Transformer , E) 12 Mm Lt Bush Rod For 33/11 Kv Transformer , F) 20 Mm Copper Bush Rod Assembly For 33/11 Kv, 10 Mva Power Transformer With Oil Seal , G) Silica Gel , H) Oil Seal For 33/11 Kv Power Transformer , I) Adaptor For Bush Rod Extension For 33/11 Kv Power Transformers , Oil Temperature Indicator 6-Inch Dia , Winding Temperature Indicator 6-Inch Dia , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm , 10 Mm Thick , Rubberized Cork Gasket Sheets 2000 Mm X 2000 Mm, 8 Mm Thick , Rubberized Cork Gasket Sheets2000 Mm X 2000 Mm, 6 Mm Thick , Relays A) Numerical Relay 3-Pole (24-50 V) 3 O/C And 1 E/F Relay ( Abb Ref615/Ge Alstom) , B) Master Trip Relay 24-50 V , B-24 , C) Master Trip Relay Ashida (Make) 18-52 (V) , D) Ashida Numerical Relay 2 O/C & 1 E/F , 33 Kv & 11 Kv Insulatorsmake Iec, Bhel, Rastriya, Top Line, Tcpl Or Any Other Reputed Make Conforming To Relevant Is Specification A) 33 Kv Pin Insulator With Pins (Porcelain Type) , B) 33Kv Pin Insulators For Panther Conductor With Pins (Polymer Type) With Base Pin 25 Mm , C) 33Kv Pin Insulators For Wolf Conductor With Pins (Polymer Type) With Base Pin 25 Mm , D) 33Kv Pin Insulators For Dog Conductor With Pins (Polymer Type) , E) 33 Kv G.I. Pins , F) 11 Kv Pin Insulator (Polymer Type) With Pins , G) 11 Kv Pin Insulator (Porcelain Type) With Pins , H) 11 Kv G.I. Pins , I) 11 Kv Disc Insulator (B & S Type) 70 Kn (Porcelain Type) , J) 33Kv Disc Insulators (Polymer Type) , K) 33 Kv Post Insulator , L) 22 Kv Post Insulator , M) 11 Kv Post Insulator , N) Drive Insulator Of Sorts , O) 11 Kv Guy Insulator , P) 33 Kv Guy Insulator , 33 Kv Tension Fittings For Acsr Dog Conductor, B&S 3 U-Bolts Type (Approx. 2.8 Kg) , 33 Kv Tension Fittings For Acsr Wolfconductor, B&S 4 U-Bolts Type (Approx. 3.8 Kg) , 33 Kv Tension Fittings For Acsr Panther Conductor, B&S 4 U-Bolts Type (Approx. 4.6 Kg) , 33 Kv Suspension Fittings For Acsr Dog Conductor , 33 Kv Suspension Fittings For Acsr Wolf Conductor , 33 Kv Suspension Fittings For Acsr Panther Conductor , Hardware & Clamps For Conductor A) 33 Kv Isolator Clamps For Acsr Dog Conductor (Heavy Duty) , B) 33 Kv Isolator Clamps For Acsr Wolf Conductor (Heavy Duty) , C) 33 Kv Isolator Clamps For Acsr Panther Conductor (Heavy Duty) , D) 33 Kv Pt Clamps For Acsr Panther Conductor(Heavy Duty) , E) 33 Kv Pt Clamps For Acsr Wolf Conductor (Heavy Duty) , F) 33 Kv Pt Clamps For Acsr Dog Conductor (Heavy Duty) , G) 33 Kv Ct Clamps For Acsrpanther Conductor (Heavy Duty) , H) 33 Kv Ct Clamps For Acsrwolfconductor(Heavy Duty) , I) 33 Kv Ct Clamps For Acsrdog Conductor(Heavy Duty) , J) 33 Kv La Clamp For Acsr Panther Conductor (Heavy Duty) , K) 33 Kv La Clamp For Acsr Wolf Conductor (Heavy Duty) , L) 33 Kv La Clamp For Acsr Dog Conductor (Heavy Duty) , M) T-Clamps For Acsr Panther Conductor (Heavy Duty) , N) T-Clamps For Acsr Wolf Conductor (Heavy Duty) , O) T-Clamps For Acsr Dog Conductor (Heavy Duty) , P) Pg Clamps For Panther Conductor (Heavy Duty) , Q) Pg Clamps For Wolf Conductor (Heavy Duty) , R) Pg Clamps For Dog Conductor (Heavy Duty) , Nuts & Bolts 4/8, 5/8 & 6/8 Dia Of Different Lengths (Full Threaded) , Galvanized Nuts & Bolts Of Different Lengths (Full Threaded) , G.I. Spring Washers , Aluminium Thimble 95Mm2 , Aluminium Thimble 120Mm2 , Aluminium Thimble 185Mm2 , Aluminium Thimble 240Mm2 , Aluminium Thimble 300Mm2 , Aluminium Thimble 400Mm2 , Aluminium Thimble 630Mm2 , Paints (Make Asian, Burger, Nerolac Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) Aluminium Paint , B) Red Oxide Paint , C) Black Paint , Cold Galvanizing Compound Cold Galvanizing Compound For Anti Corrosive Galvanized Protection To Steel Structure, Dried Flow Of Compound Containing 95% Metallic Zinc , M-Seal , Welding Rod 3.5 / 4 Mm (Electrode) , Pvc Tape , Empire Tape , Para Plast Compound , Earth Wire , Guy Wire 7/16 , G.I. Wire (8Swg) Of Sorts , Barbed Wire , Manilla Rope 1 Inch Thick , Manilla Rope 1½ Inch Thick , P.P. Rope 1 Inch Thick , P.P. Rope 1½ Inch Thick , Emergency Lights , Insulation Rubber Mat (1 M X 2M) X 12Mm Thick , Rubber Boots , Search Light / Dragon Light With In Built Charging System , 33 Kv Electrical Safety Gloves (Meet Or Exceed Astm D120 And Iec En60903 Standards) , Safety Belts Of Standard Quality , Safety Helmets Of Standard Quality , Electrical Insulating Rubber Matting Iec/Bs En 61111:2009 , Megger 500V-1000V-2500V-5000 V ( All In One)With Pi Feature , Non-Contact High Voltage Detector (Wrist Type) 1Kv To 500Kv , Ip54 Protection Level , Frp Telescopic Earth/Discharge Rod For 11 To 33 Kv System (Assemble Length:-20 Feet) , Tool Kit Complete With Tool Box , Drill Bit 18/20/25/28Mm , I/C Switch 200 Amp , Fire Extinguisher For Electrical Sub Stations Of Relevant Is Specifications , A)Co2 (4.5 Kg) , B) Power Based(Abc Type) 4 Kg. , C)Power Based(Abc Type) 6 Kg. , D)Power Based(Abc Type) 9 Kg. , Fire Buckets With Stand , Anti Climbing Device , Turn Table , Aluminium Jointing Sleeve , Mid Span Compressor Joint For Panther Conductor , 11 Kv Isolators & 33 Kv Isolators A) 11 Kv Isolator With Earthing Blade 630 Amp (Polymer) , B) 11 Kv Isolator Without Earthing Blade 630 Amp (Polymer) , C) 33 Kv Isolator With Earthing Blade 1250 Amp (Polymer) , D) 33 Kv Isolator Without Earthing Blade 1250 Amp (Polymer) , E) 11 Kv Isolator 600 Amps With 25 Ka Breaking Capacity Double Break Type With Complete Manual Operating Mechanism. , 11 Kv Hg Set , 11 Kv Do Set , 11 Kv G.O Set , 11 Kv Link Set With 50 Mm Copper Strip , 33 Kv Isolator Jaws (Plate Type) Heavy Duty , 33 Kv Isolator Jaws (Pipe Type) Heavy Duty , Battery Chargers & Batery Bank &Ac / Dc Distribution Board A) 36 Volts Battery Bank 100 Ah, 2 V, 18 Nos Cellscomplete With All Accessories , 30V, 25Abattery Charger Automatic (Float & Boost) Thyristor Based Chargers (Compatible For Vrla Batteries) , B) 30 Amp Manually Operated Battery Charger. , C) Maintenance Free 30 V Lead Acid Battery (Vrla) Bank Comprising Of 16 Nos Of 2 Volt Cells Of 100 Ah Capacity , D) 30 V Battery Charger Automatic (Float & Boost) Compatible For Vrla Batteries , E) 30 Volt, Dc Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , F) Ac Distribution Board Indoor Type, Floor Mounted Made Out Of 14/16 Swg Crc Sheet, Dust, Vermin Proof, Duly Powder Coated And Wired As Per Standard Engineering Practice , Rectifier , Delta ( Dpr 2000B-24), Id:A2, Input ( 100-240V Ac, 15A Max, 50-60 Hz), Output ( 26.7 V Dc, Max: 2000 W Suitable For Use In Delta Electronics (I) Pvt Ltd Make,Model: 30V Dc Dcps,Smps Based Dc Power System. , Main Control Card Suitbale For Use In -Fcbc Make: Digital Electric (P) Ltd , Input 1Ph, 230 V , 50 Hz & Output Float: 33.4 V Dcboost: 34.5 V Dc, 40 A Charger) , Lightening Arrestors (10 Ka, Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) A) 11 Kv L.A. Set (Station Type) Polymer(Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , B) 33 Kv L.A. Set (Station Type) Polymer (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , C) 11 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , D) 33 Kv L.A. Set (Station Type) Porcelain (Make Oblum / Raychem / Rashtriya / Adinath / Or Any Other Reputed Make Conforming To Relevant Is Specifications, Compatible Strictly For Safety Of System) , Control Cable Armoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , Control Cable Unarmoured A) 2.5 Mm2 Cu 2-Core , B) 2.5 Mm2 Cu 4-Core , C) 2.5 Mm2 Cu 6-Core , D) 2.5 Mm2 Cu 8-Core , E) 2.5 Mm2 Cu 10-Core , F) 2.5 Mm2 Cu 12-Core , G) 2.5 Mm2 Cu 16-Core , 11 Kv Vacume Interupter Bottle (1200A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , 11 Kv Vacume Interupter Bottle (800A) A) G.E.C. , B) Crompton Greaves , C) Allind , D) Alstrom , E) Bhel /A.B.B , H.T. Tape , 33 Kv Xlpe Power Cable (Make Havells Or Any Other Reputed Make Conforming To Relevant Is Specifications) A) 33 Kv Single Phase Xlpe Cable 630 Mm2 B) 33 Kv, 3 Phase Xlpe Cable 400 Mm2 C) 33 Kv, 3 Phase Xlpecable 300 Mm2 , D) 11 Kv Single-Core Xlpe Cable 630 Mm2 , E) 11 Kv 3-Core Xlpe Cable 400 Mm2 , F) 11 Kv 3-Core Xlpe Cable 300 Mm2 , G) 11 Kv 3-Core Xlpe Cable 240 Mm2 , H) 11 Kv 3-Core Xlpe Cable 185 Mm2 , I) 11 Kv 3-Core Xlpe Cable 120 Mm2 , J) 11 Kv 3-Core Xlpe Cable 95 Mm2 , Twin Core 16 Mm2 Pvc Cable (Al) , Pvc Cable 3.5 Core Armoured X35 Sqmm , Pvc Cable 4 Core Armoured 16Mm² , 3.5 Core Lt Cable 50 Mm² Armoured , Earthing Material A) Charcoal , B) Salt , C) G.I. Plate (2X 2) , D) G.I. Pipe 40 Mm F (1½) , E) G.I. Pipe 50 Mm F (2) , F) G.I. Strip 25X3 Mm , G) G.I. Strip 50X6 Mm / 25X6 Mm , G.I. Flat 50X6 Mm / 50X8 Mm , Aluminium Bus Bar Strip 75X6 Mm , Aluminium Bus Bar Strip 100X10 Mm , Copper Bus Bar 10Mm /12 Mm Thick , 11 Kv Danger Plates With Clamps , 33 Kv Danger Plates With Clamps , 66 Kv Danger Plates With Clamps , Mesh Fence Of Different Sizes , G.I. Mesh Fence Of Different Sizes , Transformer Oil Confirming To Is-335-1993 With Ammendmentsup To Date , 33 Kv Ct Of Different Ratios , 33 Kv Pt Of Different Ratios , 33 Kv Vcb , 33 Kv C&R Transformer Panel With Differential Protection , 33 Kv C&R Line Panel , 66 Kv Ct Of Different Ratios , 66 Kv Pt Of Different Ratios , 66 Kv La Set , 66 Kv Isolator Set With Earthing Blades , 66 Kv Isolator Set Without Earthing Blades , 66 Kv C&R Transformer Panel , 66 Kv C&R Line Panel , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Acsr Tiger Conductor , Acsr Wolf Conductor , Acsr Panther Conductor , Street Light / Yard Light (100 Watt) , Street Light / Yard Light (250 Watt) , Led Bulbs (9W) Isi Mark , Led Bulbs (15W) Isi Mark , Led Bulbs (30W) Isi Mark , Led Bulbs (50W) Isi Mark , Lifting & Pulling Machine (Capacity 5 Ton To 8 Ton) , Safety Chart 3X2 Ft, Laminated Board , 11 Kv Indoor Incomer Vcb Panel 1250 A , 11 Kv Outdoor Vcb Panel 1250 A , 11 Kv Indoor Incomer Vcb Panel 800 A , 11 Kv Outdoor Vcb Panel 800 A , Exhaust Fan 20 Inches, Heavy Duty , Digital Multimeter Of Standard Ratings , Digital Clampmeter 1000 A, Ac/Dc , Aet 23 Earth Tester , Agm Alct 60 A, Ac/Dc Leakage Clampmeter , Insulation Tester 5 Kv, (Ithv-501000), 0-100000 M? (Voltage-5000 V) , 11 Kv Earthing Rod , 33 Kv Earthing Rod , Iron Of Sorts Ms Angle 50X50x6 , Ms Flat 50X6 , Ms Angle 65X65x6 , Ms Channel 100X50x6 , 11 Kv Capacitor Banksapfc Relay, Siemens, Model: 7Ug0571-1Ft20 , Apfc Relay, Unistar, Model: Us-Ht-5004 , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 600 Kvar Stage. Reactor Rating 1 Ph = 0.40 Kvar, Inductance /Phase = 1.70 Mh, Reactance/ Phase = 0.53 Ohms, Rated Volatge = 11 Kv , Rated Current = 27.38 A, Class Of Insulation = F , Air Cored, Air Cooled Aluminium Wound, Epoxy Resin Impregnated Reactor ( For Indoor Use) For 1200 Kvar Stage. Reactor Rating 1 Ph = 0.80 Kvar, Inductance /Phase = 0.85 Mh, Reactance/ Phase = 0.27 Ohms, Rated Volatge = 11 Kv , Rated Current = 54.77 A, Class Of Insulation = F , 11 Kv Indoor Epoxy Resin Cast Residual Volatge Transformer, 3-Phase 5 Limb, 11 Kv/V3/110V/V3-190V, , Tar Steel 8 Mm , Tar Steel 10 Mm , Tar Steel 12 Mm , Tar Steel 16 Mm , Tar Steel 20 Mm , Cement , Ht Tape For Xlpe Cables , True Rms Digital Multimeter (Rishabh / Fluke / Megger) , 0-20 A, Digital Clamp Meter (Rishabh / Fluke / Megger) , 33 Kv Isolator With E/B (Porcelain) , 34 Kv Isolator Without E/B (Porcelain)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Jammu And Kashmir View Result →
26.
Textiles #10732252 AOC
Supply, Installation, Testing And Commissioning Of Cctv Surveillance System At 140 Warehouse Locations-2 Supply & erecting of high defination 5 MP IP IR Bullet camera with Sensor : 1/3, progressive scan, 5.0 megapixel, CMOS, Lens : [email protected]/ [email protected], Shutter Speed : Auto/Manual, 1 ~ 1/100000s, Digital noise reduction : 2D/3D DN, Day/Night : IR-cut filter with auto switch (ICR), Minimum Illumination: Colour: 0.03Lux (F2.0, AGC ON) 0Lux with IR, IR Range : Up to 30m (98ft) IR range, S/N : >56dB, Defog:Digital Defog , WDR: DWDR/ True WDR, Resolution : 5 MP or better ( 2592x1944), Video Compression : H.265 / H.265+, High Light Compensations : TRUE, Back Light Compensations :TRUE,Network : 1 RJ45 100M Base-TX Ethernet, Audio : Audio In / Out Support,Power : 12V DC / PoE, Housing : IP67 , CERTIFICATION : Vendor should submit Mfr. Test Certificate,Cyber Security : AES 256-bit Encryption, Configuration encryption, trusted execution, digest, security logs,WSSE ,account lockout,syslog, video encryption, IP/MAC filtering ,HTTPS,Trusted upgrade,trusted boot., ANR Support : Yes with 512 GB For details technical specification no 13. 3 Supply, installation, testing and commissioning of 8 channel network video recorder with Processor : Quad-core embedded processor, IP Camera Input : 8 channels, Operating System : Embedded LINUX, Two-way Talk : 1 Channel Input, 1 Channel Output, RCA, User Interface : GUI, Video Output : 2 HDMI, 2 VGA, Compression : Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Decoding Capability : 8-ch@1080P(30fps), 16-ch@1080P(30fps), OSD : Camera title, Time, Camera lock, Motion detection, Recording, Video Resolution : HDMI: 3840 × 2160 , 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768 and VGA: 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768, Video Recording : Max 160 Mbps, Video Display Split : 1st Screen: 1/4/8/9/16, 2nd Screen: 1/4/8/9, Motion Detection : MD Zones: 396(22×18). Video Loss: supports, Camera Blank : Supports,Hard Disk : 2 SATA ports, up to 10TB Each, 1 eSATA port, Smart Phone : iPhone, iPad, Android Phone, Trigger Events : Recording, PTZ, Tour, Alarm, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips, Recording Mode : Manual; schedule (general; MD; alarm; MD & alarm; intelligent; POS), Search Mode : Time /Date, Alarm, MD and Exact Search (accurate to second) , Bit Rate : 16Kbps ~ 20Mbps Per Channel , Sync Playback : 1/4/9/16 , Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoom , Backup Mode : USB Device/Network, Interface Ports : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 ), 1 RS232, 1 RS485 , Max User Account : 128 users , Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec , Ethernet : 1 RJ-45 Port (10/100/1000Mbps) , Protocols : HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search , ONVIF 2.4, SDK, CGI , Power Supply : Single, AC 100~240V, 50/60 Hz/Single, DC12V/4A , Power Consumption : <9.5W (Without HDD) , Certification : UL,CE,FCC,BIS For details technical specification no 16. 4 Supply, installation, testing and commissioning of 16 channel network video recorder with Processor : Quad-core embedded processor, IP Camera Input : 16 channels, Operating System : Embedded LINUX, Two-way Talk : 1 Channel Input, 1 Channel Output, RCA, User Interface : GUI, Video Output : 2 HDMI, 2 VGA, Compression : Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Decoding Capability : 16-ch@1080P(30fps), OSD : Camera title, Time, Camera lock, Motion detection, Recording, Video Resolution : HDMI: 3840 × 2160 , 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768 and VGA: 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768, Video Recording : Max 300 Mbps or better, Video Display Split : 1st Screen: 1/4/8/9/16, 2nd Screen: 1/4/8/9, Motion Detection : MD Zones: 396(22×18). Video Loss: supports, Camera Blank : Supports,Hard Disk : 4 SATA ports, up to 16TB Each, 1 eSATA port, Smart Phone : iPhone, iPad, Android Phone, Trigger Events : Recording, PTZ, Tour, Alarm, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips, Recording Mode : Manual; schedule (general; MD; alarm; MD & alarm; intelligent; POS), Search Mode : Time /Date, Alarm, MD and Exact Search (accurate to second) , Bit Rate : 16Kbps ~ 20Mbps Per Channel , Sync Playback : 1/4/9/16 , Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoom , Backup Mode : USB Device/Network, Interface Ports : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 ), 1 RS232, 1 RS485 , Max User Account : 128 users , Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec , Ethernet : 1 RJ-45 Port (10/100/1000Mbps) , Protocols : HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search , ONVIF 2.4, SDK, CGI , Power Supply : Single, AC 100~240V/Single, DC12V/4A , 50/60 Hz , Power Consumption : <16.7W (Without HDD) , Certification : UL,CE,FCC,BISFor details technical specification no 15. 5 Supply, installation, testing and commissioning of 32 channel network video recorder with Processor : Quad-core embedded processor, IP Camera Input : 32 channels, Operating System : Embedded LINUX, Two-way Talk : 1 Channel Input, 1 Channel Output, RCA, User Interface : GUI, Video Output : 2 HDMI, 2 VGA, Compression : Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Decoding Capability : 32-ch@1080P(30fps), OSD : Camera title, Time, Camera lock, Motion detection, Recording, Video Resolution : HDMI: 3840 × 2160 , 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768 and VGA: 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768, Video Recording : Max 320Mbps, Video Display Split : 1st Screen: 1/4/8/9/16/25/36, 2nd Screen: 1/4/8/9/16, Motion Detection : MD Zones: 396(22×18). Video Loss: supports, Camera Blank : Supports, Hard Disk : 4 SATA ports, up to 20TB Each, 1 eSATA port, Smart Phone : iPhone, iPad, Android Phone, Trigger Events : Recording, PTZ, Tour, Alarm, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips, Recording Mode : Manual; schedule (general; MD; alarm; MD & alarm; intelligent; POS), Search Mode : Time /Date, Alarm, MD and Exact Search (accurate to second) , Bit Rate : 16Kbps ~ 20Mbps Per Channel , Sync Playback : 1/4/9/16 , Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoom , Backup Mode : USB Device/Network, Interface Ports : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 ), 1 RS232, 1 RS485 , Max User Account : 128 users , Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec , Ethernet : 1 RJ-45 Port (10/100/1000Mbps) , Protocols : HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search , ONVIF 2.4, SDK, CGI , Power Supply : Single, AC 100~240V, 50/60 Hz , Power Consumption : <16.7W (Without HDD) , Certification : UL,CE,FCC,BISFor details technical specification no 14. 6 Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD 7 Supplying & erecting( 32 Monitor ) 32 professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 250 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 2 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc.complete. 8 Supplying & erecting (43 Monitor ) 43 professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete. 9 Supplying & erecting (49 Monitor ) 49professional LED display with 1920*1080 (Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete. 10 Supplying, erecting & terminating 5 m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19pin HDMI connectors complete. 11 Providing & erecting 7 m high (clear height) galvanised Each octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no.OH-PL/OPL. 12 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mmstonemetal,(45 x45 x45)cm/45cmdia.x45cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) 13 Supplying and erecting Lshape mounting for camera (Extender) etc complete as directed by engineer in charge. 14 Supplying , fixing and configuring ethernet managed ethernet each switch of minimum of 24 ports 10/100/1000 Base-T PoE+ ports with min 180W power and 2x 1G SFP portsand 1 x Out of Band IP based management Port with CL1 provided, switch of min. 36 Gbps or morewith non-blocking architecture forwarding rate of 26.8 Mpps rack, equipped with minimum 512MB RAM and 128MB flash, should have LED indicator for per port status, FAN, PSU and Management status and sustain 0°C to 50°C OT and 10% to 95% RH as directed. It should support for IPv6 , cover transmission distance of 250 meter. The swithching and routing should have 16 K MAC Address, 255 active Vlans, 802.1D spanning Tree, 802.1w, 802.1s, should have BPDU Guard, support aggregating and load balancing, 802.1 AK for dynamic VLAN propagation, Local and Remote port mirroring, Link Layer Discovery Protocol (802.1ab), MAC address tracking and address addition, delete or movement. The secutrity LA database for RADIUS Authentication for 802.1x login, SSH-2, SCP for secure management, dynamic arp inspection, DHCP snooping with min50 ACL entry support. Management should consist scheduled archiving / uploading of configuration and system log to a central server, Auto-install support for firmware images and configuration files and vendor shouldsubmit Mfr Test Certificate along with supply as directed by Engineer in chargeas per technical specification no. 1 complete. 15 Supplying , fixing and configuring ethernet managed ethernet each switch of minimum of8 Ports 10/100/1000 Mbps PoE+ 2 nos of1G SFP Ports, 2 Uplink ports, Protocol: IEEE802.3af, IEEE802.3at, Hi-PoE, consumption of PoE Budget: 120 W, with switching capacity 20 Gbp, FR rate 11.90 Mbps, buffer memory 1.5MB, should covertransmission distance 250 meter, MAC Address List- 8k. The lighting protection 6KV, working temperature –10° C to 55° C (14° F to 131° F), Electromagnetic- FCC CFR 47 FCC Part 15 Subpart B, Conforms to CE Standards. Vendor should submit Mfr Test Certificate along with supply as directed by engineer in chargeas per technical specification no. 2 complete. 16 Supplying & erecting Mode SFP transceiver of Single LC receptacle optical interface compliant with 7dB gainetc model, Hot-pluggable SFP footprint type, OW of 1310nm FP laser transmitter, standard RoHS compliant and Lead Free, should reach Up to 10 km on 9/125um SMF, with Metal enclosure for lower EMI, Low power dissipation <600mW, should sustain 0~50°C, Same as Switch make, Vendor should submit Mfr Test Certificate along with supply and complete as directed by engineer in chargeas per technical specification no. 3 complete. 17 Supplying and installing UTP CAT6 copper cablesuitable for networking of type 23 AWG Solid Bare Copper, Unshielded Twisted 4 Pair, Category 6, LSZH jacket complying to testing, cable outer diameter of 5.8mm, frequency 600 MHz; ETL Test Reports of ANSI/TIA-568-C.2 & ISO/IEC 11801 of cable performance upto 600 MHz provided conduit/casing-n-cappingas directed by engineer in charge and per technical specification no. 11. 18 Supplying, installing and testing UTP connector (RJ-45) as per specification no. WG-NAS/UTPC 19 Supplying and fixing 1 m UTP patch cordof Cat 6 type Electrical performance guaranteed to meet or exceed TIA/EIA 568-B 2-1 category 6 and ISO /IEC Category 6/class,certification UL listed, UL-C certified, different color (Green, orange and red with connector complete as directed by engineer in charge and submit mfr test reportas per technical specification no. 12 complete 20 Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. 21 Supplying and installing 6 core Optical Fiber unarmored cable unitube gel filled for access outside building Single Mode, 9/125 microns, bending radious of not more than 20X , 10 GBPS speed compliant to IEC 60793/IEC 60794 standards, change in Attenuation < = 0.05 db/km, Tensile strength >=300 N, Maximum Crush Resistance 1000 N/100mm,OT of -300 C to 500 C, storage temperature of -400 C to 550 C, of standards ISO/IEC11801 TIA/EIA-568-B, Vendor should submit Mfr Test Certificate along with supply complete as directed by engineer in chargeas per technical specification no. 6 complete. 22 Power Cable (MCB with closed box, single phase) -Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper m PVC unarmoured cable provided conduit/trunking/inside pole/Bus bars or any other places. as per technical specification No: 17 23 PVC Conduit with Hanging wire -Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (1-1-12) 24 Supplying and fixing 6 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fiber cables in provided U rack complete as per specification no. WG-NAS/ LIU 25 Supplying and fixing LIU 12 Port loaded SM with SC connectors ports provision for 12 Nos. of SC Termination. light guide unloaded interconnect unit, rack mounted type, with adapter panel Fully loaded with SCtype duplexfor termination of optical fiber cables, 19 Rack mountingin provided U rack complete as per technical specification no. 7. 26 Supplying and erecting 12 core Fibre termination box (External rack) suitable for FTTx application,IP67 grade, accepts up to 12 fusion splice, splice tray should be with adaptors and couplers as per requirement, PVC, material of Solid and fully-closed structure of dust-proof, pleasing and neat appearance, ferruling of each core as per standards provided at the time of installation etc complete as directed by engineer in charge.Vendor should submit Mfr Test Certificate along with supplyas per technical specification no. 8 complete. 27 Supplying and erecting 6 core Fibre termination box (External rack) suitable for FTTx application,IP67 grade, accepts up to 6 fusion splice, splice tray should be with adaptors and couplers as per requirement, PVC, material of Solid and fully-closed structure of dust-proof, pleasing and neat appearance, ferruling of each core as per standards provided at the time of installation etc complete as directed by engineer in charge. Vendor should submit Mfr Test Certificate along with supplyas per technical specification no. 8 complete. 28 Supplying and installing single mode simplex pigtail with SC/LC splicing, SC Connector with single mode fiber pigtail (To be used for arc fusion splicing with Fiber cores termination inside LIU/fiber interconnecting panel.) Pigtail consists of pre-moulded/prefabricated SC type fiber connector at one end & another end fiber core with approx. 1 meter length as directed and Vendor should submit Mfr. Test Certificate along with supplyas per technical specification no. 10 complete 29 Supplying and erecting duplexOFC patch cord SC-LC typefibre patch cord, SC-SC /SC-LC duplex, of 1 meter lengthetc complete as directed by engineer in charge. Vendor should submit Mfr. Test Certificate along with supply.as per technical specification no. 9 complete 30 Supplying and fixing 6Uwall mount rack or better, Two Vertical and 2 horizontal cable managers, PD of 5 points- 5 AMP socket, depth of 550 mm or as per NVR sizing, Aluminum extruded profile,compliance CE & RoHS , Glass door in front with lock, With min 2 fans for outdoor,19” equipment mounting or extra width, with 1 tray, should confirm standard of DIN41494 or equivalent ISO9001:2015 and 14001:2015. Vendor should submit Mfr Test Certificate along with supply as directed by engineer in charge as per technical specification no. 5 complete. 31 Supplying and fixingOutdoor 4Uwall mount rack or size as per requirement; bidder to study each PoP location and confirm size in technical and commercial offer, one Vertical and one horizontal cable manager if required, power distrubution with min 3 points- 5 AMP socket or as per site requirement, depth of 400 mm, Aluminum extruded profile , IP rating of 67 if outdoor use,Glass door in front with lock or metal door with perforations, fan type ventilation to be provided for outdoor unit as per requirement at site. Vendor should submit Mfr Test Certificate along with supply as directed by engineer in charge as per technical specification no. 4 complete. 32 Supplying, erecting, testing and commissioning of 2KVA online UPS with Isolation Transformer& 2 KVA = 2 KW capacity online pure sine wave UPS, with batteries PWM & IGBT based, with 0.9 to unity output pf complete with all protections as per technical specification no. 18 complete.
Contract Date: May 15, 2026 Contract Value : 7.88 Crore
Government Departments No of Bidders 8
Maharashtra View Result →
28.
Educational and Research Institute #10687064 Price Bid
Construction Of Screen House 156 Sqmtr-02 Nos. Construction Of Screen House 156 Sqmtr-02 Nos. , Size ( 12 Mtr. 13 Mtr. Side Height 3.5 Mtr. Center Height 5 Mtr ) , Structure ( Multi-Span, Dome Shaped, Welded As Well As Dismantlable ( With Nut-Bolts And Clamps ) , Gi Pipes ( Round Gi, 60Mm, 50Mm, 24Mm, 50X25mm Pipe Thickmness-2.2 / 2.0Mm Gi Pipe Hot Dip Galvanized ) , Galvanization Quality ( All Pipe Should Be Deep Hot Galvanized. Corrosion Resistant And Isi Mark ) , Poly Film Cladding Of Roof ( 200Micron Thick Uv Stabilized ( Garware / Ginegar Ir Make ) ) , Fixing Of Sheet ( ?The Complete Polyfilm To Be Fixed With G.I. Profile & Locking Spring ? Profile To Be Fixed With Self- Drilling Steel Screws , Side Ventilation ( Side Ventilation All Four Sides 3M Above Skirting / Side Wall Of Stainless Steel ( 55 ) Insect Net Of 304Grade, 40 Mesh, Ss Mesh Fixed With Aluminium Strips, Manual Rolling With Gear System , Gutter ( Trapezoidal, Gi , With Drainage Connection ) , Gutter / Side Height ( 3.5M From Ground Level ( Includes Skirt Wall ) , Ridge Height / Centre Height ( 5.0M From Ground Level ( Includes Skirt Wall ) , Shading System ( 50% Shade Factor , Uv Stabilized White Colour , Mono-Tape ( Make Garware / Netion ) , Provided Inside The Structure With Manually Folding-Spreading System ) , Side Rolling ( 4 Sides, Manual Rolling With Gear System, Of Polyfilm Of Garware Ir / Ginegar Make ) , Buffer Room ( 2Mx1.5M With Double Door Entry .Doors Made Of Gi Pipes And Cladded With Polyfilm Buffer Room Will Have All The Switches. / Mcbs , Misting System ( 54 No. Four- Way Foggers ( 22.5Lph ) , Laterals , Pump, Filters, Etc. Netafim / Automat Make, With Pvc Fittings, 1.5 Hp Pump ( Crompton / Arise ) Make. 500Its Water Tank Of Sintex / Equivalent Make ) , Drip Irrigation System ( 16 Lines Of 16 Mm Pipe With Inline Dripper At 30Cm Spacing ( Netafim / John Deere Make ) .Water Pump Of 1.5Hp ( Crompton / Arise ) Make. Filter- Automat / Netafim Make 1000 Lts Water Tank Of Sintex / Equivalent Make With Complete Plumbingof Pvcpipe ( Prince / Supreme / Isi Marked Make ) , Electricals ( Copper Cables, Isi Marked For Pump, Mcb, Main Switch , Etc. ) , Civil Work ( Skirt Wall Of Brick / Local Stone, 9 Inches Thick, 1.5Ft Below Ground And1.5Ft Above Ground ) , Data Logger ( Temperature & Humidity Data Logger Model Number : Mta L 12 Data Logger Feature ( A ) 2 Channel ( B ) 0-5 V Input Ports ( C ) Rs 232 / Rs485 / Modbus & Gprs Communication Port ( D ) Set Point Feature In All Channel ( E ) 20X4 Lcd ( F ) Gui Software For Online Server & Mobile App ( G ) Gsm Facility Can Fetch Receive Data On Mobile Phone ( H ) 8 Gb Memory Card Storage ( I ) Direct Interface To Pc ( J ) Single Relay For Controlling The Application ( K ) Battery Operated ( Back Up Up To 6-8 Hour ) Wireless Interfacing Method ( A ) Modbus ( B ) Etherner Wireless Interfacing Method ( A ) Gsm / Gprs ( B ) Wifi Sensor Specification Temperature Sensor Range 0? C To 70? C Accuracy + / - 0.5?C Humidity Sensor Range 0 To 100% Accuracy + / - 3%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Arunachal Pradesh View Result →
29.
Housing Urban and Rular Development #10653330 Price Bid
Conceptualization, Design, Engineering, Supply, Installation, Testing, Commissioning, And Integration Of Sound System With Existing Facade Lighting At Shri Mahakal Temple Conceptualization, Design, Engineering, Supply, Installation, Testing, Commissioning, And Integration Of Sound System With Existing Facade Lighting At Shri Mahakal Temple , Conceptualization, Design, Engineering, Supply, Installation, Testing, Commissioning,And Integration Of Sound System With Existing Façade Lighting At Shri Mahakal Temple. , Supply, Installation, Testing And Commissioning Of Dmx Module + Audio Video Controller For 512 Channels Of Dmx Driven Lighting Fixtures. Dmx Splitters, Connectors And Including Power Supply For Dmx Pharos Controls/Crestron/Equivalent , Supply, Installation, Testing And Commissioning Of 4.3 Poe Powered, 480X272, Landscape Or Portrait, 4.3 Touch Screen Panel For Controlling Lighting Schematics Pharos Controls/Crestron/Equivalent , Supply, Installation, Testing And Commissioning Of 24 Port Gigabit Poe, Unmanaged Ethernet Switch Net Gear/Cisco/Equivalent , Ethernet Data Node For E-Dmx 10 Universe Node. Two Neutrik Ether On For Rj45 10/100 Dt/Management Nodes. Ten Rdm Compatible Pharos Controls/Crestron/Equivalent , Poe Powered, Audio In Module For Dynamic Audio Feed In. Volume Level And Up To 30 Band Spectrum Analysis Per Channel, Including Peak Decay Rate Control And Manual Or Automatic Gain. Max 4 Audio Inputs Per System. Pharos Controls/Crestron/Equivalent , Iot Gateway For Remote Monitoring, Scheduling And Programming. With Lan/Wifi Connectivity. Ewon/Cisco/Equivalent , Supply, Installation, Testing And Commissioning Of Programming Software, Client Operation Application, Remote Monitoring Software And LicenseFees , Supply, Installation, Testing And Commissioning Of Api Link Sharing License Pharos Controls/Crestron/Equivalent , 24 U Equipment Rack D-Link / Val Rack/Equivalent , Supply, Installation, Testing And Commissioning Of Accessories And Connectors , Supply, Installation, Testing And Commissioning Of 8 Two-Way Weatherized Speaker System With Ev Dh2005 Hi-Frequency Compression Driver. 100X100 Coverage Pattern. Includes Quicksam Mount Bracket And 4 Pole PhoenixesConnector. Includes Transformer For 70/100V Operation At 6.5, 12.5, 25, 50,100 Watts. Black HighImpact Polymer Cabinet. Electro Voice Ev-Zx1i-100Tb Or Equivalent. , Supply, Installation, Testing And Commissioning Of Terminal Cover For 8 Two-Way Weatherized Speaker System. Includes Weatherized Gland Nut Fitting – Black Electro Voice Ev-Tc-Zx1i-Blk Or Equivalent. , Supply, Installation, Testing And Commissioning Of 5” Cabinet 70/100V Ip65 With Two-Way, Full-Range, 5.25 (133 Mm) Surface Mount Speaker With Excellent Wide, Uniform Dispersion, And Outstanding Performance. It Is Designed For Background And Foreground Music, Voice Evacuation, Paging, And Sound Reinforcement, And Its Ideal For A Wide Variety Of Indoor And Outdoor Applications, Such As Restaurants, Bars, Patios, Retail, Fitness Clubs, Hospitality, Theme Parks, Leisure Venues, And Others. Electro Voice Evid5.2Xor Equivalent. , 4-Channel Power Amplifier, 4 X 1000W Into 2, Or 4 Ohms, Or 70V/100V Direct Drive, 2U, Ready For Rcm-810 Iris-Net Remote-Control Module, In/Outputs Phoenix Type, 230V. Electro Voice Ev-Cps4.10 Or Equivalent. , Supply, Installation, Testing And Commissioning Complete Dsp Zone Matrix Mixer And Loudspeaker Processor 4 Microphone/Line, 3 Music Sources, Call Station And Emergency Inputs 8 Independent Output Zones, And “Amp Link” Outputs Ethernet Control And Windows Pc Gui, And An Ios App For Zone Control Via Iphone And Ipad Rs485 Connection For Call Stations And Wall ControlPanel. App Control Available For Ios. And Software Control For Windows And Mac Bosch-Plm-8M8 Or Equivalent. , Plena Matrix 8 Zone Call Station Capacitive Touch Programmable Zone Selection Modern Aesthetic Design Powered From Plm-8M8 Loop-Through To Connect With Either More Call Stations Or Wall Control Panels Bosch-Plm-8Cs Or Equivalent. , Supply, Installation, Testing And Commissioning Of 1.5 Sq. Mm., 2 Core, O2 Free Speaker Cable (In Mtrs) , Supply, Installation, Testing And Commissioning Of Accessories And Controllers , Opex Year 1 , Opex Year 2 , Opex Year 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Madhya Pradesh View Result →
30.
Educational and Research Institute #10625357 Price Bid
Supply Of Instruments / Equipments=1.00 Flow Meter 1.01 Size : 40- 100 Mm 1.02 Flow Range : 25- 250Ml / Mnt 1.03 Volume Per Revolution : 0.309L 1.04 Greatest Pressure : 2.5 Mpa 1.05 Accuracy : ±0.2% 1.06 Repeatability : ≤0.05% 1.07 Standard Unit : Rise 2.00 Co2 Probe 2.01 Exact Application : Measurement Of Dissolved Co2 In Microalgae Culture 2.02 Measurement Range : 10 To 1000 Mbar Co2 2.03 Accuracy : ± ( 10 % Of The Reading + 10 Mbar ) 2.04 Operating Temperature :0 To 60 °C ( 32 To 140 °F ) 2.05 Mechanical Temperature Resistance : – 20 To 130°C ( – 4 To 266 °F ) 2.06 Operating Pressure : 0.2 To 2 Bar ( 3 To 30 Psia ) 2.07 Mechanical Pressure Resistance Max. : 3 Bar ( 42 Psia ) At 25 °C ( 77 °F ) 2.08 Response Time T90 : At 25 °C ( 77 °F ) < 120S 2.09 Steam Sterilizable And Autoclavable : Yes 2.10 Cable Connection : Ak 9 2.11 O2 Selective Membrane Material : Ptfe / Silicone 2.12 Shaft Diameter : 12 Mm 2.13 Available Lengths : 220- 320 Mm 2.14 Distance Between Sensor And Transmitter : 40Mm 2.15 Blind Transmitter : Ok 3.00 Palletizer Machine 3.01 Body Material : Hardened Mild Steel 3.02 Output Capacity : 20 To 50 Kg / Hr 3.03 Pallete Size Die : 8Mm To 10Mm 3.04 Motor Power Capacity : 3 To 5 Hp 3.05 Roller : 1 Set 3.06 Palletizer Mill Weight : 90 Kg 3.07 Palletizer Mill Size ( H X L X W ) : 36 X 48 X 24 3.08 Movement Of Palletizer Mill : Trolley On Wheels 3.09 Shape Of Hopper : Round 4.00 Shredder Machine 4.01 Cutting Mechanism : Twin Shaft 4.02 Shred Chamber ( Mm ) : 310×310 4.03 Shred Size ( Mm ) : 8×50-100 4.04 Shred Capacity : 200-300 Kg / Hr 4.05 Voltage : 415V 4.06 Power : 3 Hp 4.07 Hopper Volume ( Liters ) : 60 L 4.08 Waste Volume ( Liters ) : 180 L 4.09 Weight : 275 Kg 4.10 Running Cycle : Continuous 5.00 Soxhlet Appratus 5.01 Automatic Pc Compatible Solvent Extraction System ( Digital ) 5.02 • Fully Automatic Programmable Six Place Auto Sequencing Pc Compatible Solvent Extraction System 5.03 • Tft Graphic Touch Screen Display With Unique Wireless Mouse To Operate Directly Without Connecting To Pc. 5.04 • Icons To Represent Output Of Heating Process In Touch Screen Display 5.05 • Selectable Programs ( Customizable ) : Integrated Auto Sequencing Features With Intelligent Memory Programs Minimum 50 Programme With 10 Sequencing Steps With Inbuilt Datagger With User Id, Channel Name, Scan Rate, File Browse Feature To Download Stored Data With Inbuilt Software For Usable Csv And Excel Format 5.06 • Data Logger With Real Time Clock With Memory Stick For Data Storage With Separate Port In Mother Board Apart From Pc Port 5.07 • The Advanced Superior Pc Chart Software Performs Live Graphical Representation Of Time / Temperature Gradient On Touch Screen Display Directly. 5.08 • Temperature Range: 35°C ( Ambient ) To 300°C, Temperature Accuracy / Precision : + 0.5° C 5.09 • Temperature Controller Should Be Isolated Separately In A Control Tower To Protect Electronics From Solvent Area & Heat Zone For Safe Operation 5.10 • Measuring Range: 0.1 To 100% Fat / Oil 5.11 • Repeatability: + 1% Or Better 5.12 • Speed Of Extraction: 40 To 60 Minutes Depending On Application 5.13 • Auto Phase Change Of Extraction Includes Boiling, Condensation, Rinsing, Solvent Recovery & Predrying 5.14 • Inbuilt Airpump, Ss Manifold, Automatic Collection Of Recovered Solvent, Versatile Sizes Of Thimble ( Extra Thimble Should Be Provided ) 5.15 • Upgradeable Remote Control Module For Wireless Data Monitoring, Control And Transfer To Pc At A Distance Of 5-10 Feet. The Entire Display Screen Of Controller Should Wirelessly Appear In The Pc / Laptop Of User, To Monitor & Control From His Work Table. 5.16 • Electrical Requirement:230V / 50Hz. Ac Mains. 5.17 Refrigerated Water Cooling Circulating System 5.18 • Refrigerated Water Cooling Circulating System With Digital Display Of Temperature, 5.19 • Microprocessor Based Pid Temp. Controller, Temperature Range: 10°Cto 20ºc. 5.20 • Inbuilt Safety Features With Ce Certification To Fulfil All Statutory Requirement Of Good Laboratory Practice. Auto Over Temperature Protection / Auto Error Indication / Auto Sensor Break Protection, Over Load Protection. 5.21 • Ss Tank, Submergible Pump For Recirculation, Ms Powder Coating Housing 5.22 • The Instrument Should Be Approved Registered Brand & Shall Strictly Confirm To The Specifications With Relevant Brochure & Photograph As Per Specification. 6.00 Recirculating Chiller 6.01 Temperature Range: -10~100ºc 6.02 Precision:±0.2 6.03 Cooling Capacity At 20°C -800W 6.04 Interior Dimensions:150X160x150mm 6.05 Chamber Volume:4.5L 6.06 Electrical Requirement:220V 50Hz 6.07 Pump Flux:8L / Min 6.08 Power Consumption : 2300W 6.09 Microprocessor Temperature Controller 6.10 Audible And Visible Alarm For Temperature And Water Level 6.11 R134a Refrigerant, Imported Compressor With Interface To External Water Bath 6.12 Rs485 Connector To Connect Computer To Record The Parameters And The Variations Of Temperature. 7.00 Portable Gas Analyser ( Syn-Gas ) 7.01 Method Of Detection : Ndir Infrared Sensor For Co, Co2 And Ch4 Electrochemical Sensor For O2 & H2 7.02 Ranges Available O2 0-25.0%, 0-50.0%, 0-100.0% Co 0-10.0%, 0-50.0%, 0-100.0% Co2 0-10.0%, 0-50.0%, 0-100.0% Ch4 0-50.0%, 0-100.0% H2 0-5.0% 7.03 Resolution : 0.1% For All Gases 7.04 Accuracy & Repeatability : ± 2% Of Reading For All Gases 7.05 Drift : Less Than 2% Of Full Scale Per Month 7.06 Response Time ( T-90 ) : 20-30 Seconds To 90% Step Change 7.07 Ambient Temperature Range : 4 To 50°C 7.08 Power : 12V / 24V Dc Adaptor 7.09 Output Options : Rs 232 Interface For Data Logging 8.00 Sieve Shaker With Sieve 8.01 Heavy Duty ( Improved Model ) For 8 Inch Test Sieve 8.02 The Sieve Shaker Is Durable Constructed And Is Run By ¼ H.P. Electric Motor 220 Volts A.C. Through Reduction Gear. 8.03 Designed To Carry Upto 6 / 7 Test Sieve Of 200Mm Dia ( 8 Inch ) With One Set Lid & Pan. 8.04 It Produces Circular And Hammering Motion Is Given At Top. 8.05 It Reproduce Circular ( Revolution Approx.: 280 To 320 R.P.M And Tapping Approx.: 140 To 160 R.P.M. 8.06 No Foundation Required. 8.07 7 Nos. Of Test Sieve ( Dia 8 Inch ) Made-Up Of Brass With Different Sizes Such As 106 Μm, 150 Μm, 212 Μm, 250 Μm, 300 Μm, 500 Μm, 850Μm. 8.09 One Set Lid And Pan With Above Specification. 9.00 Moisture Analyser 9.01 Max. Capacity : 50 G 9.02 Readability ( Weight ) : 0.1 Mg 9.03 Readability Moisture : 0.0001% 9.04 Repeatability ( Sample 2G ) ( Sd ) : 0.05% 9.05 Repeatability ( Sample 10G ) ( Sd ) : 0.02% 9.06 Units Of Measurements : %M, %D, %R ( Ratio ) , Gm / Lt, %M Atro, %D Atro 9.07 Statistics : Method Wise For Each Individual 40 Methods Or Batch Wise For Each Individual 100 Batches For Last 999 Results 9.08 Technology : Infra Red Halogen 9.09 Temperature Range : Max. To 175°C ( Optional To 250ºc ) 9.10 Temperature Increment : Interval 1ºc 9.11 Heating Profile : Standard, Gentle, Rapid, Steps, High Temperature 9.12 Switch Off Criteria : Auto, Manual 9.13 Auto Method Development : Intelligent 9.14 Method Memory : 40 And Batch Memory : 100 9.15 Method Designation : Alpha Numeric 9.16 Serial Number : Yes 9.17 Compile : Yes ( Method Linking ) 9.18 Operating Temperature : 15ºc To 35ºc 9.19 Display : Graphical Lcd Display With Led Backlite 10.00 Filter Vacuum Pump 10.01 Wetted Parts 304 Stainless Steel, Free Air Capacity ( Lpm ) ≥28 Max Flow Rate ( Cfm ) ≥ 0.99 Max Flow Rate ( Litters / Min ) ≥28 Max Pressure ( Psi ) ≥ 60 Max Pressure ( Bar ) ≥4.14 Max Vacuum ( Mbar ) ≥ 500 Noise Level ( Db ) ≥ 68 Port Size ¼ Npt ( F ) 3 / 4 Hose Barb On Gauges Noise Level : 50.00 Db 10.02 Filtration Unit 10.03 Material Type: Glass Diameter: 50Mm Capacity: Upper Chamber-500 Ml, 1000Ml, Lower Chamber-500Ml Sintered Crucible Nylon 66 Membrane & Filter, Filterpaper Nontoxic, Unbreakable Polysulfone Funnel Is Used In Microbial And Particulate Analysis. Funnels Do Not Leak After Repeated Autoclaving Removal Membrane Support Plate Is Designed To Provide Maximum Flow Rate And Through Put. Filtration Assembly Made Of Borosilicate Glass With Fritted Glass Filter Base The Base Design Has An Integral Vacuum Connection Located Above The Filtrate Drip To Prevent Contamination Of The Vacuum Line From Droplets The Filtration Base Has A Silicon Stopper, Anodized Aluminum Spring Clamp Facilitates Analysis Of Particulate Or Biological Contamination Of Vacuum Filtering Liquid The Scaled Funnels Simplify Dosing And Analysis 11.00 Lambda 365 Double Beam Uv Spectrophotometer Compatible Accessories Kit 11.01 50 Mm Trans / Reflect Sphere High Sens Used For Measuring The Diffuse Reflectance ( Sce ) , Total Transmittance, Diffuse Transmittance And Performing Color Analysis. It Has A Spectral Range Of 230-1100 Nm ( Uv And Visible ) . Its Port Size Is 10.00 Mm And The Spectral Bandwidth Is 20Nm. 11.02 Powder Sampling Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 9
31.
Defence #10588341 Price Bid
Tender For Upgradation Of Campus Electrical Infrastructure Atc-Dot Campus, New Delhi.; 1 Supply, retrofitting, and testing of the existing LT panel with new 1600A, 4-pole, microprocessor-based ACBs in place of the existing 1250A ACBs, including dismantling of old breakers, modification of panel structure, alignment, and necessary wiring & copper bus-bar for proper integration. The scope also includes upgradation of the metering panel with RS485-compatible energy meters. All work shall ensure compatibility with the existing system and conform to IS:13947 and IEC:60947 standards. 2 Supply, retrofitting and testing of MCCBs in the existing LT panel with new 400A, 4-pole MCCBs, in place of existing or vacant feeders, including removal of the old units, modification of the mounting arrangement, connection to existing wiring, and full functional integration. The MCCBs shall be thermal-magnetic or microprocessor-based, conforming to IS:13947 standards. The scope also includes the addition of the energy meters for power monitoring. 3 Supply, installation, testing, and commissioning of UPS Input LT Panel fabricated with CRCA sheet steel, floor-mounted, dust and vermin-proof, IP42 rated or more, suitable for 415V, 3-phase, 4-wire system. The panel shall be equipped with two (2) 1600A ACB incomer feeders, one 1600A ACB bus coupler, Six (3+3) outgoing ACBs (1000A/800A), four (4) outgoing MCCBs (250A), and spare feeders. The panel shall include a copper busbar rated for 1800Amp or above, digital metering on incomer and outgoing feeders, indication lamps, earthing studs, and proper cable termination facilities. The design and construction shall conform to IS:8623 / IEC 61439 standards. 4 Supply, installation, testing, and commissioning of UPS Output Panel for UPS-1, comprising two incoming MCCBs of 800A (from UPS-1 output) and three outgoing MCCBs of 630A (to distribution panel). Panel shall be CRCA sheet steel, IP42 rated, floor-mounted, fully wired, factory fabricated, and conforming to IS:8623 / IEC:61439 standards. 5 Supply, installation, testing, and commissioning of a new UPS-1 Output Distribution Panel, comprising one (1) main incomer MCCB (630A) with integrated energy metering, two (2) outgoing MCCB feeders (250A), and four (4) outgoing MCCB feeders (100A). The panel shall be complete with wiring, terminations, and labeling, and shall conform to IS:8623 / IEC 61439 standards for design, construction, and safety compliance. 6 Supply, installation, testing, and commissioning of 600 kVA Isolation Transformer, type K-13 for UPS Output Panel, suitable for 415V, 3-phase, 50Hz system. Includes proper mounting, interconnection with UPS panel, earthing, and cable terminations. Transformer shall be air-cooled, copper wound, and conform to relevant IS/IEC standards. 7 Supply, laying, proper termination (including supply and installation of suitable cable glands and lugs as required on Site), and testing of 240 sqmm, single-core, stranded copper conductor cable, XLPE insulated, PVC sheathed, suitable for 1.1 kV grade as per IS:7098 (Part I). Suitable for high-load applications, with excellent thermal, mechanical, and electrical properties, for indoor/outdoor use. Supplied with factory test certificates, laid on cable trays. 8 Supply, laying, proper termination (including supply and installation of suitable cable glands and lugs as required on site), and testing of 3.5-core, 25 sqmm, stranded copper conductor cable, XLPE insulated, PVC sheathed, suitable for 1.1 kV grade as per IS:7098 (Part I). Designed for medium-load applications, offering excellent thermal, mechanical, and electrical properties for both indoor and outdoor use. Supplied with factory test certificates and laid on cable trays. 9 Supply and installation of a dedicated earthing system for the UPS Input and Output Panels, including a separate earth electrode as per IS:3043 standard, galvanized steel earth busbar for each panel, and properly sized copper or aluminum earthing conductor. The earthing system shall ensure effective grounding with an earth resistance value not exceeding the recommended limit (typically ≤ 1 ohm), providing a safe and efficient path for fault currents. 10 Supply, Installation, Testing, and Commissioning (SITC) of perforated Galvanized Iron (GI) Cable Tray of size 600 mm (width) × 62.5 mm (height) × 2 mm (thickness). 11 Supply, Installation, Testing, and Commissioning (SITC) of suitable earthing strips or cable for electrical panels, along with eight (8) new earthing pits. 12 Using the existing BBT (1250A) as a power source from the LT Panel to the UPS Input Panel, ensuring proper connection, secure termination, and compliance with safety standards. 13 Removal of existing Riello MHT 250 kVA UPS (1 Nos.) and integration (connecting) into the existing UPS system (i.e., UPS-1) to configure a single power source. 14 Removal of existing old 100 KVA UPS units (2 Nos.) along with its output panel, including disconnection of all electrical/mechanical connections, safe dismantling, handling, and shifting to designated storage area. 15 Appropriate assessed value for the buyback of the existing UPS Input Panel and its corresponding Output Panel, including dismantling, removal from site, and safe transportation as per standard procedures. 16 Quote Price (Without GST) 17 Quote Price (Without GST)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
32.
Water Resources and Irrigation #10558790 Price Bid
Supplying, Installation, Testing & Commissioning of Mix-flow type Electric Pump Sets & equipments with all accessories etc. including development of Substation for New Pump House at Jahangirpuri drain near Gopalpur Regulator RD-1135m.- 1 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 55 KW/75 HP , 6 Pole , 980 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 35x35 Size Pump set having 1400 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 2 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 75 KW/100 HP , 8 Pole , 740 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 40x45 Size Pump set having 2000 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 3 Supplying , installation, testing and commissioning of Sound Proof Steel enclosure Water Cooled Engine coupled with Alternator 320KVA/256 KW silent DG Generator set including Base frame, Radiator/Heat Exchanger/Fuel Tank/ Control Panel /AMF panel, fuel piping foundation, all interconnections, loop Earthing, Silencer completed all as per CPWD/CPCB norms with standard accessories etc. as required.(Make:- Crompton Greaves/ Kirloskar/ Cummins or as approved by Engineer-in-charge) 4 M.S. Pipes:-Manufacturing , Supplying, erection & commissioning of Mild Steel ERW, (Electric Resistance welded) Pipe fabricated/manufactured out of Fe410 Mild Steel Grade 330 as per IS: 3589 of reputed & approved make , including painting with epoxy paint inside and outside surface with two coats of anticorrosive paint of approved brand and manufacture : all conforming to relevant IS codes: complete in all respect and with upto date amendments in relevant IS codes:(Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge)1200mm nominal dia pipes of 12mm thick complete as required at site. 5 350mm nominal dia pipes of 8mm thick complete as required at site. 6 400mm nominal dia pipes of 8mm thick complete as required at site. 7 450mm nominal dia pipes of 8mm thick complete as required at site. 8 MS Flanges:- Manufacturing, Supplying, fixing & welding of following sizes M.S. Flanges etc complete. as requiredat site. 1200mm dia. & 25mm thickness. 9 350mm dia. & 20mm thickness. 10 400mm dia. & 20mm thickness. 11 450mm dia. & 20mm thickness. 12 MS Bends:-Manufacturing, Supplying, fixing & welding of following sizes M.S. Bends etc. complete. as requiredat site. 1200mm dia. 13 350mm dia. 14 400mm dia. 15 450mm dia. 16 MS Dummy Flanges:-Manufacturing, Supplying & fixing of M.S. Dummy Flanges etc. of following sizes complete as required at site. 1200mm dia. & 25mm thickness. 17 350mm dia. & 16mm thickness. 18 400mm dia. & 25mm thickness. 19 C.I. Sluice Valves:-Providing & Fixing of following sizes Cast Iron Sluice gate Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 20 450 mm nominal dia. 21 C.I. Non Return Valves :-Providing & Fixing of following sizes Cast Iron Non Return Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 22 400 mm nominal dia. 23 Nut/Bolts/Washers:-Manufacturing & Supplying of Nuts,Bolts & Washers etc. of size 7/8 x 6 as required at site. 24 Rubber Gaskets:-Manufacturing, Supplying & Fixingof Rubber Gaskets of thickness 6mm or more for following sizes M.S. Pipelines Flanges as required at site.1200mm nominal dia. 25 350mm nominal dia. 26 400mm nominal dia. 27 450mm nominal dia. 28 Vaccum Pump:-Supplying, Installation, Testing and Commissioning of DV-50 Vaccum Pump sets having C.I. casing and C-40 shaft with 10 H.P. energy efficiency LV motor, 3 phase, 415volt 50hz, 1500RPM +/- 5%, TEFC induction motor mounted on suitable size M.S.base frame coupled on existing foundation withall accessories like ML 1.5 starter, anti vibration mounting pad, coupling, nut-bolts & packing etc. complete in all respect i/c providing, fitting & testing ofheavy class M.S. pipe of 50mm dia.of requiredlength with necessary Gate valve and mountings etc.for chargingof pump sets. ( Pump:- Kirloskar make or as approved by Engineer-in-charge) (Motor:- Kirloskar/Crompton /ABB or as approved by Engineer-in-charge) (Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge) 29 Supplying, installation, testing & commissioning of Energy efficient 630 KVA, 11/0.433 KV, 3 phase, 50Hz, Dyn11, outdoor ONAN type, copper wound Transformer with off load tap changing arrangement on HV side , Tapping range +5% to -10% in steps of 2.5%having Cable boxes on HV/LV side suitable for 3 x 240 Sq.mm. XLPE Cable of 11 KV grade with accessories, buckholz relay i/c first filling of filtered dehydrated oil and confirming to IS 335& Transformer losses as per IS 1180 level-2 & as per specification attached complete in all respects as required at site. • Max Continuous Rating = 630 KVA • Voltage Ratio = 11/0.433 KV• Tapping (Range/ Step) off Circuit Tap Changer = +5% to -10% in step of 2.5% off load • Insulation Class = A Class • Application of the Transformer = Distribution• Vector Group = Dyn 11• Temperature Rise at Rated Load over Ambient of 40°/50° C• Cooling = ONAN(Make:- Kirloskar/Schenider/ABB or as approved by Engineer-in-charge) 30 Supplying, Installation, Testing and Commissioning of Indoor Type Floor Mounted metal clad, 11KV VCB Panel with 1 No. VCB for ICOG System (Incoming-Outgoing System), Totally Enclosed. Horizontal drawout, Horizontal/Vertical Isolation type Breaker as per IS 13118 & as ammended upto date and additional specifications as mentioned below, manually charged and motorized /manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated Aluminium Bus Bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 3 x 95 sqmm XLPE 11 KV cable (cable entry frombottom/top/side) (MAKE:- Kirloskar/ L&T/ Crompton/Schenider)1. All CTs and PTs shall be cast resin type.2. 2. All PTs should be Fixed type.Detailed Specifications:-1 Nos. 800A TP Electrically drawout type Vacuum Circuit Breaker, 11KV, 20KA/3 seconds suitable for 630A TP, EDO, 18.4KA/1 second with following accessories:a)Spring Charge Motor, 240V A.C, Closing Coil 24V DC, Shunt Trip Coil 24V DC, Operation Counter with Mechanical ON/OFF Push Buttonb)Mechanical Indicator ON/OFF, Aux. Contacts 4NO + 4NC, Spring Charge/Discharge,Mechanical Spring Charging Device.c)Mechanical Emeregency Push Button2. 1 No. 11 KV / 110V PT class 0.5 accuracy and 100 VA burden with 1 No. voltmeter (0-15 kV), digital type, selector switch for voltmeter and protection fuses / MCB for HT metering up to 12 KV on incomer.3. 1 No. Microprocessor based numerical relay with O/L,E/F and S/C protection.4. 1 sets of 3 nos dual core dual ratio CTs 50/50/5/5A of 15 VA burden and accuracy class - 0.5 for metering and class 5P 10 for protection.5. Flush mounted Type High Speed Tripping Relay,6. Flush mounted Type DC Operated Auxiliary relay for Transformer Faults with Three Pair of Relay Element7. 1 Nos. Anti Pumping relay8. Annunciator Set 8 Window Type with Hooter for Fault Indication9. Supplying, Installation, Testing and Commissioning of Power pack with 220 volt AC input & 24 volt DC continuous output suitable for closing / tripping / indication of 1 No. HT Panel Boards with 2 Nos. 12 volts each maintenance free batteries of 100 AH each, charging unit, capacitor bank for emergency delivering for Trip system complete with suitable capacity of Ammeter & voltmeter i/c connections with 2.5 sqmm FRLS insulated copper conductor cable etc. as required. 31 Fabrication Supply Installation Testing and Commissioning of Main L.T Panel suitable for 415 Volt, 3 Phase 4 Wire System, 50Hz AC Supply. Panel Shall be fabricated out of 1.6MM thick CRCA Sheet for load bearing and non load bearing members, Gland Plate shall be fabricated out of 2MM thick CRCA Sheet. Panel shall be Powder coated with RAL 7032 Shade for Doors and Body and have suitable solid links for Incoming ond Outgoing of the ACB with Electrical Grade Aluminium of 1000 Ampere Capacity supported on DMC/SMC Bus Bar Supports. Earthing shall be done with 25 X 5MM G.I Strip running acroos the Panel Length. The Control Wiring for Metering and Display Instruments shall be done with PVC Insulated 1.1KV Grade multi stranded copper wire of 2.5 Sqmm. Proper Ventilation system for heat disipation shall be provided with Panel including ventialtion fan and louvers. The Panel Shall not be less than 1875 X 2000 X 750 m.m or Cm³(H,L&D) The Panel shall be fitted with the following switchgear & instruments as mentioned below:-Incoming:-a)1000A TP ACB, Manually Type with following protection features such as Overload and Shor Circuit protectionb)Digital Type Multifuntion Meter, bearing Cl 1 Accuracy without RS485 Portc)Phase Indication Lamps for R-Phase, Y-Phase and B-Phase, 240V A.Cd)ACB ON and OFF Indication Lampse)6A SP MCB, 10KA Breaking Capacity for Protection and Control Circuitf)1 Set of 1000/5 CT, CL-1.0, 15VA Burden Tape WoundOutgoing:-a)55KW Star Delta Starter with ML4 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosb)30KW Star Delta Starter with ML3 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosc)400A TP MCCB, 36KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nosd)200A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.e)125A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.f) 100A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nos. 32 Supplying, installation, testing & commissioning of Cubical Type Phase sequence corrector suitable for 415 Volt, 3 Phase 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2mm thick CRCA sheet of size for frame work and covers, having Gland plate less than 3mm including cleaning and finishing complete with powder coating in approved shade, having links not less 600A capacity. the Bus Bar support (wherever required) with short curcuit withstand capacity of 31 MVA for 1 sec.Entire panel shall have a common Earth Bus of suitable size at the Rear with 2 Nos. Earth stud, solid connections from main Bus Bar to switch Gears with requires size of Aluminium Bus Bar (wherever required) and control wiring shall be done with 2.5 sq.mm PVC insulated copper conductor single core cables. Including providing and fixing the following switch Gear.A) Materiala) 580A Three Pole Power Contactors, AC3 Duty, Coil voltage 220 V A.C: 2 Nos. (Make:- ABB/L&T/C&S)b) LED type indication Lamps RYB (3 set) Aux. Supply: 220V A.Cc) Control Miniture Circuit Breaker (3 Nos.) SP, 10KA : 6Ad) Single Phase Digital Type Ampere Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 accuracy, CT-Input-5A, Aux. Volt-220V,ACe) Ampere Selector Switch (1No.) Rating : 6Af) Single Phase Digital Type Volt Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 Accuracy, Range:- 0-500 V, Aux. Volt:220V, A.Cg) Voltage Selector Switch (1No.) Rating : 6Ah) Current transformer 600/5A, Single Ratio, Single Core, 1Ø (3 Nos.) , Tape wound, CL-1.0 & 15VAi) LED type Indication LampsON/OFF (2 set) Aux. Supply: 220V A.Cj) Auto/ Manual selector switch (2 Nos.), Rating : 6Ak) Phase Sequence correction relay (1 Nos.) Aux Volt :220V, A.Cl) Audio Indication for Phase sequence Reversal(1 Nos.) Hooter : 220V A.C.m) On Delay Timer (1 Nos.) Aux Volt :220V, A.C 33 SITC of 200KVAR APFC Panel made out of 1.6mm Thick CRCA Sheet duly powder coated complete with suitable size of Al. Bus Bars & internal wiring with suitable size of Copper wire including Providing and Fixing following Switchgear and Metering instruments complete as required. Panel size shall not be less than 1575m.m or Cm³*1900*350.. the Capacitors Shall be Divided as per the mentioned Pattern for 200KVAR SystemA) MaterialMain Incomer:-a) 400A TP MCCB, Thermal based Release with O/L & S/C Protection: 1 Nos.b) Rotary Operating Mechanism: 1 Nos.c) Phase Spreaders: 1 Setd) 12 Stage APFC Relay, Microprocessor Based, with Different Display Parameters.e) Phase Indication Lamps, 220V-240V AC : 3 Nos.2) Outgoing:-a) 63A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 6 Nosb) 40A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.c) 25A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.3) 200 KVAR Capacitor, MPP and Cylindrical Type:-a) 25KVAR Capacitor Bank: 6 Nos.b) 15KVAR Capacitor Bank: 2 Nos.c) 10KVAR Capacitor Bank: 2 Nos.4) Capacitor Duty Contactors of Various Ratings for Capacitor Switching:-a) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 25 or Equivalent : 6 Nosb) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 15 or Equivalent : 2 Nosc) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 10 or Equivalent : 2 Nosd) Side Mounting Block : 10 Nose) Push Button with Element Set for Manual Start & Stop of Capacitor Bank : 10 Setsf) Indication Lights for Capacitor ON Indication : 20 Nos.g) 4 Ventilation Fans with Louvers for Cross Air Ventilation : 1 Nosh) Auto/Manual Selector Switch for Auto/Manual mode of Operation : 1 Nos. 34 Copper Conductor LT Cables:-Supplying, Laying and fixing of following sizes P.V.C. insulated and P.V.C. sheathed/ XLPE CopperConductorarmoured Cable of 1.1 KV grade as per IS:1554 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)4C x 10 sqmm. 35 4C x 120 sqmm 36 4C x 150 sqmm 37 Aluminium Conductor LT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 1.1 KV grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)3.5C x 300 sqmm 38 3.5C x 150 sqmm 39 Aluminium Conductor HT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 11 KV(E) grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. 3.5C x 300 sqmm(Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge) 40 Supply and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 16 sq. mm 41 4 x 35 sq. mm 42 4 x 10 sq. mm 43 Supply and making outdoor end jointing with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 11 KV grade as required.3C x 300 sq. mm 44 Supplying & fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth busbar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 6 way, Double door 45 8way, Double door 46 Supplying and fixing metal box of 100mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 47 Supplying, installation, testing & commissioning of energy efficient LED Flood light luminaries of system wattage 72 watt complete with mounting brackets & accessories i/c connections complete as required.(Make:- Bajaj/Philips/Crompton/Halonix) 48 Supplying and fixing followingpiano type switch/socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch 49 15/16 amp switch 50 3 pin 5/6 amp socket outlet 51 6 pin15/16 amp socket outlet 52 Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. 53 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, , miniature circuit breaker suitable for inductive load of folloeing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole 54 Single pole and neutral 55 Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVS insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular plate, sitable GI Box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C) 56 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2x2.5 sq.m + 1x2.5 sq.m earth wire 57 2 x 4 sq. mm +1 x 4 sq.mmearth wire 58 Supplying, installation, testing and commissioning ofHeavyduty following sizes exhaust fan 900 RPM totally enclosed heavy duty motor with die castaluminium rotor suitable for operation on 240 volts 50 Hz AC single phase Supply including installation of exhaust fan in the existing opening, making good the damages as required. .(Bajaj, Usha, Khaitan, Havells, Orient ) or as approved by Engineer-in-charge.450 mm Sweep 59 Supplying, installation, testing and commissioning of 1200 mm sweep AC electric ceiling fan capacitortype with double ball bearing complete with down rod, canopies, shackles, blades but without regulator suitable for operation on 230/240 volts, 50 Hz single phase AC supply including wiring the down rod of standard lenth up to 1 mtr with 2x1.5 sq. mm PVC insulated copper conductor with fan sheet etc. as required.(Make:- Bajaj/ Usha/ Khaitan/ Havells/ orientor as approved by Engineer-in-charge) 60 Supplying, installation, testing & commissioning of prewired Indoor decorative 18/20 watt LEDbatten extruded aluminum housing& opal diffuser. IP20 complete with all accessories including connection making etc. as required. (Make:- Bajaj/ Halonix/ Havell’s/ Crompton/ Phillipsor as approved by Engineer-in-charge) 61 Supplying and fixing of following size P.V.C. insulated sheathed /XLPE Aluminum conductor cable of 1.1 KV Grade armoured as per IS:7098 on surface as required. (National,Grandlay, Glouster, Poly-Cab, Phinolex or as approved by Engineer-in-charge). 2 x 10 sq.mm 62 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 63 Providing and fixing 25 x 5 mm G.I.strip on surface or in recess including connection etc. as required. 64 Providing and laying 6 SWG G.I wire on surface or in recess for loop earthing along with existing surface/recessed/conduit/submain wiring/cable etc. as required. 65 Supplying, Installation, Testing and commissioning of 7.5 Tonne capacity Single Girder E.O.T. Crane comprising of Main Girder, End carriages -02 nos with long travel motors – 02 Nos, 01 Nos 5 Tonne capacity Wire Rope Electric Hoist, pendant controlled along with brakes, limit switches and electric panel. All motors i.e. Hoisting/ Lowering, cross travel and long travel shall be compatible with VVVF drive and the speeds can be adjusted from zero to maximum speed. The complete system includes erection of columns, LT Girders, LT rail/ Sq Bar, 01 no DSL system (Shrouded type)(MAKE: - GLOBE/ WH BRADY/ GARLIC) 66 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 150 Watt LED street lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge) 67 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 100 Watt LED Flood lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge). 68 Fabrication & installation of S.S. Bar Screen/ Jaal inside Suction side of Pump Sump in slightly inclined position of required height with M.S. Platform etc. for ease of removal of foreign materials, hyacinth, jute, bags etc. from the suction side completed etc. as required at site.Construction, maintenance and subsequent removal of earthen bundies including cost of excavation earth filling of E.C. bags with earth, stitching and placing in position for care and diversion of all kinds of water entering or flowing in the drain and pumping out surface as well as under groung seepage water to keep the construction area completely dry for execution of entire work including its execution of work in or under water and or liquid mud wherever required with round the clock watch & ward/maintenance of earthen bundies to keep the working area/site dry complete as per specification & direction of Engineer-in-charge. 69 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more. 70 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 71 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cementconcrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverableseparately). All works upto plinth level. 72 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 73 Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as Nuts, Bolts,fasteners etc.).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
33.
Public Administrative Department #10546981 Price Bid
Tender For Provision For Installation Of Cctv Cameras In Record Room At Zonal Building Under Shahdra South Zone.; 1 SITC of 4MP varifocal lens Bullet IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOSMinimum Illumination: 0.05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum:30mOperating Temperature: -20 to 55 deg CentWeatherproof Standard: IP66 or better **Safety standard: UL 2 SITC of 4MP varifocal lens Dome IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOSMinimum Illumination: 0.05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 30mOperating Temperature: -20 to 50 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL 3 SITC of 16 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or betterNetwork Throughput :80Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 1 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg CentSafety standard: UL 4 SITC of full HD LED Monitor, 42 INCHES complying with the following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 300 NITS min.Contrast : 1200 : 1 or betterPower supply : 230v + / - 10%, 50 Hz at sitewith connections andalong with all accessories etc.Complete as required. 5 SITC of 8 TB surveillance HDD 6 Supplying and drawing of UTP 4 pair CAT 6LANE ofCable in the existing surface/ recessed steel/PVC conduit as required.(a) 1 run of cable. 7 (b) 2 run of cable. 8 (c) 3 nrun of cable. 9 Supply and drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface/recessed steel/PVC conduit as required. (a)2x2.5 sqmm 10 SITC of 16 port Giga PoE switch, 16(PoE 10/100) + 2(10/100/1000) port long distance switch 11 Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 3 KVA 12 Supplying and fixing of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 25mm 13 SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.8U 14 SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U 15 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
34.
Public Administrative Department #10546972 Price Bid
Tender For Provision Of Cctv System At M&Cw Centre Of Vishwakarma Park Under Shahdra South Zone.; 1 SITC of 4MP varifocal lens Bullet IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOSMinimum Illumination: 0.05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum:30mOperating Temperature: -20 to 55 deg CentWeatherproof Standard: IP66 or better **Safety standard: UL 2 SITC of 4MP varifocal lens Dome IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOSMinimum Illumination: 0.05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 30mOperating Temperature: -20 to 50 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL 3 SITC of 8 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or betterNetwork Throughput :80Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 1 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg CentSafety standard: UL 4 SITC of full HD LED Monitor,42 INCHES complying with the following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 300 NITS min.Contrast : 1200 : 1 or betterPower supply : 230v + / - 10%, 50 Hz at sitewith connections andalong with all accessories etc.complete as required. 5 SITC of 6 TB surveillance HDD 6 Supplying and drawing of UTP 4 pair CAT 6LANE ofCable in the existing surface/ recessed steel/PVC conduit as required. (a) 1 run of cable. 7 Supply and drawing following sizes of FRLS PVC insulated copper conductor , single core cable in the existing surface/recessed steel/PVC conduit as required. (a)2x2.5 sqmm 8 SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch 9 Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 3 KVA 10 Supplying and fixing of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a) 25mm 11 SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U 12 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
36.
Water Resources and Irrigation #10512078 Price Bid
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification And Automation With Scada System Including Renovation, Furnishing Of Existing Barrage Control Room At Gaula, Barrage, Haldwani, Uttarakhand Under National Hydrolog , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. Suitable Power Supply To Power Up Plc / Rtu Panel, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Supply Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage & Head Regulators Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Monitoring. As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Barrage Pond Level Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10M Range For Measuring Down Stream Discharge Of Head Regulator Of Main Canal, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 8 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Each Plc / Rtu And Instrumentation System, As Per Technical Specifications. , Supply Of Intelligent Field Controller / Rtu As Early Flood Warning Station With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem& Siren At Specified Location, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Supply & Installation Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Barrage Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification. , Supply Of Early Streamer Emission ( Ese ) Lightning Arrestor ( Protection Radius 87 Mtr ) With All Necessary Accessories As Per Technical Specifications , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Interconnection With Relatedplc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 75” Led Display / Video Wall Based System For Monitoring Of Scada & Surveillance System At Barrage Control Room As Per Technical Specifications , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Versionclient Scada Software For Remote Viewing & Monitoring Of Complete Scada System As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications , Supply Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing Along With Accessories Complete As Per Technical Specifications. , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, Communication With Nvr Located At Barrage Control Room For Monitoring The Gates Operation Complete As Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom ( Ptz ) Cameras, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Monitoring. As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 30 M Range For Measuring Barrage Pond Level. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measuring Dowstream Water Level / Discharge Of Head Regulator Of Main Canal System. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 8 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Instrumentation System, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Monitoring Station For Remote Monitoring & Early Warning Stations, Per Technical Specifications. , Installation Testing And Commissioning Of Intelligent Field Controller / Rtu As Early Flood Warning Station, With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem & Siren At Bareli Town, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Installation, Testing & Commissioning Of Early Streamer Emission ( Ese ) Lightning Arrestorwith All Connectors, Cabling And All Required Accessories Etc As Per Technical Specifications , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Installation, Testing, Commissioning And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications , Installation, Testing And Commissioning Of 75” Led Display For Monitoring Of Scada & Surveillance System At Control Room As Per Technical Specifications , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of Systemfor Five Years. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S As Per The Technical Specifications , Installation, Testing And Commissioning Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing, Starter Panel, Energy Meter & Cabling Complete In All Respects As Per Technical Specifications. , Five Years Operation & Maintenance And Comprehensive Warranty For Gaula Barrage & Head Regulator Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimumone Service Engineer Shall Be Placed At Barrage Control Room For Operation Of Scada & Surveillance System. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttarakhand View Result →
37.
Water Resources and Irrigation #10512072 Price Bid
Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification And Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Supply, Installation, Testing, Commissioning, Training, Maintenance, Electrification, Automation With Scada System Including Renovation And Furnishing Of Existing Barrage Control Room At Ramnagar Barrage, Uttarakhand Under National Hydrology Project , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Supply Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or 4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation At Barrage & Head Regulators Complete As Per Technical Specifications. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling Required For Monitoring. As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Barrage Pond Level Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10M Range For Measuring Down Stream Discharge Of Head Regulator Of Main Canal, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Ip65 Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Each Plc / Rtu And Instrumentation System, As Per Technical Specifications. , Supply Of Intelligent Field Controller / Rtu As Early Flood Warning Station With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem& Siren At Specified Location, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Supply & Installation Of Air Condition System With Requisite Furniture And Renovation & Furnishing Of Existing Barrage Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification Located At Adwa Barrage, Mirzapur , Supply Of Early Streamer Emission ( Ese ) Lightning Arrestor ( Protection Radius 87 Mtr ) With All Necessary Accessories As Per Technical Specifications , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Interconnection With Relatedplc / Rtu’S, Complete As Per Technical Specification. , Supply, Engineering And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Supply Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 75” Led Display / Video Wall Based System For Monitoring Of Scada & Surveillance System At Barrage Control Room As Per Technical Specifications , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Versionclient Scada Software For Remote Viewing & Monitoring Of Complete Scada System As Per Technical Specifications. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications , Supply Of Diesel Generator Set 3Phase 10.0 Kva With 04 Earth Pits For Earthing Along With Accessories Complete As Per Technical Specifications. , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications. , Installation, Testing & Commissioning Of 3 Phase Vfd Starter Panelfor Each Motor Of Barrage Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Installation, Testing And Commissioning & Integration Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24-Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, Communication With Nvr Located At Barrage Control Room For Monitoring The Gates Operation Complete As Per Technical Specifications. , Installation, Testing & Commissioning & Integration With Nvr Located At Barrage Control Room Of Pan Tilt Zoom ( Ptz ) Cameras, 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip ( Digital ) Camera, 500 Mtrs. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Outdoor Weather Resistant Ip 66 Including Cabling & Conducting Required For Monitoring. As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 30 M Range For Measuring Barrage Pond Level. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation, Testing & Commissioning Of Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 10 M Range For Measuring Dowstream Water Level / Discharge Of Head Regulator Of Main Canal System. Including All Necessary Cabling, Conduits, Electrical Fitting & Mast Complete, As Per Technical Specifications. , Installation Testing And Commissioning Of Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type With Gprs / Gsm Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Instrumentation System, As Per Technical Specifications. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Monitoring Station For Remote Monitoring & Early Warning Stations, Per Technical Specifications. , Installation Testing And Commissioning Of Intelligent Field Controller / Rtu As Early Flood Warning Station, With Software Development With Metallic Front Door Opening Cabinet, Fitted With Gprs / Gsm Modem & Siren At Bareli Town, Along With Industrial Grade Electrical Fitting & Cabling With Suitable Conduits Complete, As Per Technical Specification. , Installation, Testing & Commissioning Of Early Streamer Emission ( Ese ) Lightning Arrestorwith All Connectors, Cabling And All Required Accessories Etc As Per Technical Specifications , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Or Above Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification. , Installation, Testing, Commissioning And Development Of Customized Scada Software For Complete System With Life Time Licensed Version As Per Technical Specifications. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications , Installation, Testing And Commissioning Of 75” Led Display For Monitoring Of Scada & Surveillance System At Control Room As Per Technical Specifications , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of Systemfor Five Years. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Barrage Control Room Equipment’S As Per The Technical Specifications , Installation, Testing And Commissioning Of Diesel Generator Set 3 Phase 10.0 Kva With 04 Earth Pits For Earthing, Starter Panel, Energy Meter & Cabling Complete In All Respects As Per Technical Specifications. , Five Years Operation & Maintenance And Comprehensive Warranty For Ramnagar Barrage & Head Regulator Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimum One Service Engineer Shall Be Placed At Barrage Control Room For Operation Of Scada & Surveillance System. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttarakhand View Result →
38.
Communications and Information Technology  #10457552 Price Bid
Supply Installation Testing Commissioning And Equipment For Gold Ornament Cluster Supply, Installation, Testing, Commissioning And Trail Run Of Machinery And Equipment For Gold Ornament Cluster Under Mse Cdp Scheme. , Gold Cluster Ornament , Supply And Installation Of Faceting And Milling Machine (Cnc Machine) For Bangles And Wedding Bands Double Head With Variable Speed Control, Computerizes Six Axis System. Specification: Number Of Head Horizontal & Vertical 02. Type Of Main Centre Universal 03. Number Of Axis (5+2) ‘X Longitude, ‘W D-Tilting, ‘Z Vertical For Depth, ‘R 360° Horizontal Rotary For Angular Position & Machining, ‘H Horizontal Spindle, ‘V Vertical Spindle, 04. Travel Of Axis ‘X Longitude 60 Mm, ? Rotating For Job - Continuous Rotary/Index, 2 To 400 Divisions, ‘W Tilting (Semi Rotary) Degree -40° To 90°, 05. Type Of Optional Accessories For Optimum Operation. Optional Accessories Can Be Fitted For Flat And Half Round Bangles And, Bands (Rings) 06 Milling Spindle Speed Horizontal (Servo Motor) Vertical (Hf Ac Built-In Motor With Pneumatic Tool Change Water Cooled Spindle). Min. 1000 Rpm To Max. 9000 Rpm, Min. 10,000 Rpm To Max. 60,000 Rpm ‘? Rotary,07. Spindle Motor Power Vertical, Horizontal, 1.5 Kw, 0.4 Kw,08. Electrical Supply 220V Ac / 50 Hz, 09. Total Required Electrical Load 3 Kva, 10. Air (Pneumatic) Supply Dry And Oil Free Air With 6 Bar / 87 Psi And 4 Cfm /120 Lpm Flow Rate, 11. Dimension (L X W X H) 94 X 97 X 156 Cm. 37 X 38 X 61 Inch.12 Floor Space Required (L X W X H) 155 X 161.5 X 156 Cm. 61 X 63.5 X 61 Inch,13 Net Weight With Standard Accessories 327 Kg Approx., 15 Shipping Dimension With Standard Accessories (L X W X H) Box-1 - 75 X 92 X 120 Cm. 29.5 X 36 X 47 Inch, Box-2 - 119 X 122 X 181 Cm. 47 X 48 X 71 Inch., Box-3 - 32 X 63 X 42 Cm. 12.5 X 25 X 16.5 Inch. To Include Additional Supporting Machine Tools And Materials. Fully Automatic And To Include Software Installation, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Udh - 701 Vekaria Make Or Its Equivalent. , Supply And Installation Of Bangle And Ring Turning Machine Specification: 1.5 To 3 Specification: Bangle Turning Machine (Without Any Accessories)- With Standard Inside Bangle Turning Socket - 1 Pc.- With Standard Outside Bangle Turning Mandrel - 1 Pc.- Bangle Turning Tool Holder - 1 Pc. Bangle Nylon Collets Set- Set Of 33 Inside Turning Collets (Size From 2” To 3”) And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries Or Its Equivalent. , Supply And Installation Of Bangle And Ring Profiling Machine 2 To 3 No.S 17 To No. 49 With Bangle Stretcher /Pep Tools. Specification: Combined Double Head (Horizontal And Vertical) *Simple To Calculate Divisions Up To 120 Parts*Robust Base With Mounting Holes For Hassle Free Operating*Dual Motor (1 For Each Head) (0.17 Hp/ 2800 Rpm)*Spindles (Rpm) - Horizontal – 5600 / Vertical – 6500* Motor 0.25 Hp* Machine Dimension 76X76x82 Cm, Bangle Nylon Collets With 1 Bangle Holder For Diamond Cut Faceting, Ring Nylon Collets With 1 Ring Holder For Diamond Cut Faceting, Ball Attachment, Half Ball Collets Set Of 6, Chain Attachment And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries Model Sku: 16.0701 (Bangle Ring Turning Machine) Or Its Equivalent. , Supply And Installation Of Laser Engraving Machine 12000Mm/Sec, Cooling Systemspecification: Platform - Safety Enclosure, Operating Mode - Mopa Pulse Fiber Laser, Wave Length - 1064 Nm, Pulse Frequency - Upto 2000 Khz, Output Power - 20 Watt Mopa Pulse Fibre Engine, Focusing Optics (Nm) - 100, 163, 254, Cooling Capacity - Fully Air Cooled, Heat Sink, Profile Laser (Optional) - Visible, Red Beam Pilot Laser, Laser Safety Compliance - Fda (Cdrh), Csa, Ce.With High Speed Fiber Laser Marking Technology Marking/Deep Engraving /Cutting On Precious Metals, With Dust / Fumes Collection Unit.Pulse Fiber Laser (Mopa Engines) And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: 3802 Series Laser Marker With Rotary & Laptop Of Laser Star Make From Italy Or Its Equivalent. , Supply And Installation Of Cnc Router Machine With 3D Printer With Supporting Printing Material Specification: Jewelers Engraving 3-4 Axis With Zczb Wax Printer/ Stablizer /Struller/ Chemical /Computer Set /Heater Cleaning Tools/Back Up Ups. Molding Method - Mjp, Molding Size - 294*211*144 Mm, Printing Mode - Xhd:1200*1200*1600 Dpi:16, Dimension Accuracy - + 0.04 Mm/20 Mm, Power Supply - Ac 220-240 V, 50 Hz, 3 Kw, Overall Size - 1415*790*1160 Mm, Overall, Weight - 380 Kg, Package Size - 1700 *1000*1400 Mm, Application Software - 3D Print Data Support Format - .Stl/.Slc, Operation Environment - 18-28 ° C / 30-70 % Humidity And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work. , Supply And Installation Of Digital Weighing Machine - Set Of 10 Machines With Calibration Set Up Specification: Weighing Capacity: 62 G, Resolution: 0.1 Mg, Calibration: External, Display Type: Clear Reverse Backlit Lcd Display, Standard Interface: Rs -232 C Repeatability: 0.1 Mg, Weighing Pan: Ø90 Mm And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: A&D Japan Or Its Equivalent. , Supply And Installation Of Ball Making Machine With Full Set Of Sheet Drawing Of Pipe Making, Soldering, Sheet Striping Machine, Hammering With All Standard Accessories Specification: Power: Single Phase, 220 V, Weight: 158 Kg, Dimensions: 45 X 76 X 106 Cm Suitable For Production Of Small To Large Sized Round, Long Oval, Long Barrel Shaped Balls From Strip Or Tube By Changing Dies, Size: 1.8Mm - 8 Mm, Ac Power 2 Hp Motor, 80-100 Balls Per Minute With Oil Pump, Weight 350Kg, Material Die Steel, Suitable For Production Of Balls Or Other Shapes Chain In Small Dimensions By Changing Dies From 0.60Mm Up To 2.00Mm, Ac Power 1 Hp Motor, 80-100 Links Per Minute With Oil Pump, Weight 300Kg. (Approx), High Grade Die Steel Material. With Separate Sheet Metal Drawing Machine Setup, To Manufacture Hallow And Solid Gold Ball Shapes, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Laser Welding Machine 130 Joule Capacity With 150 Joule Cap.Specification: Source Type - Nd: Yag (Flashlamp), Wavelength - 1064 Nm Output Power (Watts) - 60 W /80 W, Maximum Peak Power - 11 Kw, Pulse Frequency - 0.5 - 50 Hz, Beam Diameter - 0.05 - 2.00 Mm, Burst /Speed Welding - Optimized To Energy Values, Max Pulse Energy - 180 J, Pulse Performance Profile Technology - Exclusive Integrated Software, Soft Touch Resonator Technology - Beam Profile Technology (Optional), Supply Circuit - 120 V Or 230 V (+ 10 %)50/60 Hzfunctionality: 1. Automatic Energy Save Mode, 2. Integrated Preventive Maintenance Alerts, 3. Multi Language System Display, 4. 99 Memory Settings, 5. Preprogrammed Application Parameters Ceramic Cavity New Technology, 6. Inbuilt Cooling System Specially Designed For Jewelry Industry, And 7. Less Maintenance And More Efficient Power Supply Technology., And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Workmake/Model: Laser Star Brand Pedistal/Stablizer Or Its Equivalent , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Specification: Dies With Different Sizes And Its Supporting Consumable Materials For Die Punching Machine. 10 Mm (3/8 Inch) Letter & Number Punch Set (0 To 9) & 27 Letters, Type Of Product: Punch, Weight: 995 G, Size: 10 Mm, Material: Carbon Steel, Usage: Professional I.E., On Gold And Silverand Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries / Kravetto Or Its Equivalent , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Specification: Dies With Different Sizes And Its Supporting Consumable Materials For Die Punching Machine. Material Stainless Steel, Model Name/Number Devi: Embossing Dies, Weight 50 Gm Gross Weight 70 Gm, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/ Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes)Pattern Dimensions 3Mm - 50Mm, Material D2 D3, Usage/Application Bangle Ring Jewellery Making As Per Required Designs Quantity - 400 Pieces And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Of Gold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Pattern Type: Round, Pattern Dimensions: As Per Requirements, Usage/Application: Coin Making, Material Stainless Steel, Customization: As Per Requirements, Diameter: 1Oo Mm, Finishing: High Chromium Double Polished, Hardness: Tempered And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply Ofgold And Silver Dies Specification: Sizes Starting From 15X1 To 15.3/4X1, Quantity:1200 (Sizes Dais As Per Gold And Silver Dais As Per Sizes) Pattern: Type Square, Pattern Dimensions: As Per Requirements, Usage /Application: Coin Making, Material: Bronze And Hard Ss, Customization: As Per Requirements, Diameter: 1Oo Mm, Finishing: High Chromium Double Polishedhardness: Tempered And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Eagle Industries/ Shree Ambika Tools Or Its Equivalent. , Supply And Installation Of Digital Vacuum Pressure Casting Gold Melting Machine Capacity: 2.4Kg, With Digital Display And Cooling System.Fully Automatic Casting Machine Brand/ Reiacetech Wax Mono Endura / Indigenous Furnace 6 To 8 Flask Capacity/Matrix Investment Mixer 5 Flask/ Steam Machine /Ultra / De-Waxing/Water Jet/Manual Wax Injector/ Tools /Materials For Casting/ Cylinders Powder / Stabilizer Set For All The Machine And Support Materials. Specification:Power: 11 .0 Kw, Frequency: 6 Khz, Ac Line, (50/60 Hz), 3 Phase:400 V + 10%, Melting Temperature (Max): 1300 ° C, Crucible Capacity: 3 Kg Au, Crucible Volume: 208 Cm3, Flask Size (Min): 87 Mm X 127 Mm, Flask Size (Max): 120 Mm X 300 Mm, Vacuum Pump: Included , Weight: 290 Kg (639.3 Lb), Dimensions: 70 Cm X 101 Cm X 135 Cm, Inlet Water Temperature: 35 ° Cfunctionality: Vacuum Casting Machine With Auto/Manual Technology Operating Process With High Pressure Vacuum Motor. Add On Machines For Pre Casting And Post Casting: Reiacetech Wax Injector From Italy Or Its Equivalent. Ingenious Furnace 6 To 8 Flask Capacity With 4 Side Heating Capacity. Indeginous Investment Mixer 5 Flask Capacity. Steam Machine For Gold Tree Cleaning, Manual Wax Injector Ultra Sonaic Machine, Steam De-Waxing Machine, Tool And Consumables For Casting Unit, Stabilizer Set, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Gold Melting Machine With Digital Display And Cooling System Capacity: 2Kg With Digital Display And Cooling System, Two Models With Chiller From 50 Gm To 2 Kg, Melting Capacity / Rio Grande Melting Machine With Digital Display With Graphite Crucible Sets And 50 Gm To 500 Gm Capacity (2 Or 3 Qty Required) Specification: With Ceramic Based Crucible With Digital Thermocouple Heating Sensor Display Screen, Power - 440 V 3 Phase, Water Cooler - 35 Littre (In Built), Weight - 120 Kg, Dimensions - 36 X 30 X 45 And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Gold Refinery Machine 2Kg Charged Up To 6 Kg Per Day With Digital Display And Cooling System Should Have Excellent Thermal Insulation To Prevent Loss. Specification: Gold Refining Unit, Power Supply: 400 V / 3 Phase, Power: 0.3 Kw, Dimension In Mm: 1200 X 670 X 1120, Weight: 80 Kgs. To Have Low Running Costs, Fully Automated Process With Process Control And With Fumes Filter & Exhaust Filter And Including Cost And Conveyance Of All Material, Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Koras Refining Unit With Auto Stirrer Set Up With Acrylic Material Or Its Equivalent. , Supply And Installation Of Hydraulic Die Cutting Machine: Capacity:25 Tons, 150Mm Stoke Cylinder, 20Mm/Sec Fast Forward Speed Specification: Hydraulic Die Cutting Machine: Capacity:25 Tons, 150Mm Stoke Cylinder, 20Mm/Sec Fast Forward Speed, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: High Pressure Hydraulic Die Cutting Machine From Hk Brand Or Its Equivalent. , Supply And Installation Of Mesh Chain Machine With Standard Accessories Specification: Material: Mild Steel, Power 4.0 Kw, 5.5 Kw, Voltage 380 V, Dimension (Lxwxh) 3800Mm X 3000Mm X 1400Mm, Different Shapes Of Box Chain Making Machine With Auto Setting And Manual Operation Process. Die Replacement Or Fixing Process To Be User Friendly And To Produce Higher Production In Short Time, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Modern Chain Machines / Vekaria Or Its Equivalent. , Supply And Installation Of Box Chain Making Machine With Standard Accessories Specification: Material: Mild Steel, Power 4.0 Kw, 5.5 Kw, Voltage 380 V, Dimension (Lxwxh) 3800Mm X 3000Mm X 1400Mm, Different Shapes Of Box Chain Making Machine With Auto Setting And Manual Operation Process. Die Replacement Or Fixing Process To Be User Friendly And To Produce Higher Production In Short Time, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Modern Chain Machines / Vekaria Or Its Equivalent. , Supply And Installation Of V-Chain Making Machine With Standard Accessories Specification: Motor: 0.50 Hp Pmdc Motor & Drive Speed Control Rpm 0 – 1500. 180 Wt. 1 Year All India Warranty. Table: Machine Cabinet Steel Mattel & Weight 49Kg. Electronic Panel: Dc Drive Full Electronic Panel• Sensor (Auto Cut)• Heater (37 Wt., Temperature 800O). Features: Automatic Machine For Venetian Chains, Variable Speed Controller, Forced Lubrications System With Oil Tank And Electronic Brake Sensor, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Best Indian Heavy Duty Machine/ Vekaria Brand Or Its Equivalent. , Supply And Installation Of 12 Pass Wire Drawing Machine With Full Set Of Standard Accessories Specification:Max. Wire Diameter (Guage/Mm) = 20/0.91 To 18/1.22.•Min. Wire Diameter (Guage/Mm) = 36/0.91 To 36/0.19.•Main Motor = 1.5 To 2 Hp.•Cooling Motor = 0.25 Hp.•Machine Weight =225 To 345 Kg. Heavy Duty Sturdy Metal Frame That Holds The Motor.•Transmission Drive.•Speed Control Drive.•Cooling Liquid Tank And Sprayer.•The Unwinding Reel.•The Motorized Winding Reel With Adjustable Clutch.•Steel Palermo For Longer Durability Of Machine. And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Hk Brand Or Its Equivalent. , Supply And Installation Of Sheet And Wire Drawing Machine With Standard Accessories With Heavy Duty Motor Capacity And Auto Stopper Technology Specification: Wire & Sheet Rolling Mill For Gold & Silver • Roller Length 200 Mm X 100 Mm. • Heavy Duty Machine • Bronze Bushings • 5 Hp Electric Motor • Three Phase Power Supply • Hardened Ground Steel • Roller Mouth Openness: 20 Mm. • Weight 800 Kg, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Hk Brand Or Its Equivalent , Supply And Installation Of Laser Marking Machine Specification: Karat Mark: Laser Marker (20 / 30 W Power) Specification: Laser Power: 20 W-30 W, Laser Wavelength: 1064 Nm, Frequency Range: 20 - 120 Khz 1-600 Khz, Beam Diamter: 7+1 7 + 0.5, Format Supported: All Vector Files And Image Files (Bmp, Jpg, Gif, Tga, Png, Tif, Ai, Dxf, Dst, Plt), Scan Field: 100 X 100 Mm Scan Speed <<7000 Mm/S, Power Regulating Range: 10 -100 %, Cooling Method: Air Cooling, Operating Environment - 0° C - 40 ° C (Non -Condensing), Electricity Demand - 220 V (110 V)/50 Hz (60 Hz), Size & Weight - Around 24 X 17 X 15 In, Gross Weight Around 22 Kgs, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make /Model: Alpha Laser Marker (20/30 W Power) , Supply And Installation Of Xrf Machinemistral Sdd, Item Note: Xrf Karat Meter (Sdd) Stabilizer / Support Specification:Intended Use: Energy Dispersive X-Ray Measuring Instrument (Edxrf) To Determine Thin Coatings, Trace Elements And Alloys. Element Range Aluminium (13) To Uranium U (92) - Up To 24 Elements Simultaneously. Designs Bench Top Unit With Upward Opening Hood, Measurement Direction: From Bottom To Top, X-Ray Source, X-Ray Tube Micro Focus Tube With Tungsten Target And Beryllium Window, High Voltage Three Steps: 10 Kv, 30 Kv, 50 Kv, Aperture (Collimator) 4X Changeable: 00.2 Mm (7,9 Mils), Ø 0.6 Mm (23.6 Mils), Ø1 Mm (39.4 Mils). Primary Filter: 6X Changeable: Ni, Free, Al 1000 ?M (39.4 Mils). Al 500 ?M (19.7 Mils). Al 100 ?M (3.9 Mils), Mylar 100 Um (3.9Mils)Measurement Spot Depending On The Measuring Distance And On The Aperture In Use, The Actual Measurement Spot Size Is Shown In The Video Image. Smallest Measurement Spot Approx. 0.3 Mm (11.8 Mils) And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Fisher Xrf Sdd Brand Or Its Equivalent. , Supply And Installation Of Assay Balance: 0.001 Mg Accuracy With Mettler Toledo Scale Je3002 G/M Gold Scale 3.200 With Digital Display. Specification: Weight Capacity - 6000 G Resolution - 1000 Mg Repeatability - 0.01 G Calibration - External And Internal Display Type - Vacuum Fluorescent Display (Vfd) Weighing Pan - Ø150 Mm Standard Interface - Rs -232 C And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of Sartorius Analytical Balance Machine With Digital Display With All Standard Accessories. Specification: Weight Capacity - 6000 G Resolution - 1000 Mg Repeatability - 0.01 G Calibration - External And Internal Display Type - Vacuum Fluorescent Display (Vfd) Weighing Pan - Ø150 Mm Standard Interface - Rs -232C And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of Sartorius Precision Balance Machine With Digital Display With All Standard Accessories. Specification:Weighing Capacity: 62 Gresolution: 0.1 Mgcalibration: Externaldisplay Type: Clear Reverse Backlit Lcd Displaystandard Interface: Rs -232 Crepeatability: 0.1 Mgweighing Pan: Ø90 Mm And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Mettler Toledo Scale Or Its Equivalent. , Supply And Installation Of 50Gm, 100Gm, 200Gm, E2 Class Wire Weight With Display Attachment Item Note: 50Mg. E-2 Class Wire Weight With Nabl Calibration Certificate. Specification: Calibration Units With Stainless Steel Measuring Exact Weight Standards For Weighing Machines Block. Weights Intended To Ensure Traceability Between National Mass Standards (With Values Derived From The International Prototype Of The Kilogram) And Weights Of Class E2 And Lower. Class E1 Weights Or Weight Sets Shall Be Accompanied By A Calibration Certificate, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Tools And Equipment For Sampling Balling Pliers, Couplers, Scraping Tools, Tongs, Forceps, Rolling Mill Etc. For Complete Assay Set Up Please The Link As Provided Below, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of Furnaces, Scrubbers, Parting Tray Etc. Item Note: For Hallmarking Full Setup Center Required. (3 Phase Power, Pollution Clearance Certificate Bis Approval Fee, And All Things) Specification: Annealing Furnace With 220V / Single Phase Along With Supporting Materials. Assay Supplies: Assay Laboratory Spare Parts And Consumables, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work For Complete Assay Set Up Please The Link As Provided Above Against Item No. 29 , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements..I)Cctv Cameras With Night Vision2 Megapixel Ip Cameras With Motorized Verifocal& Pixel Zoom ; Progressive Scan Cmos 1/2.8 Or 1/3Format; Focal Length 2.8 To 12Mm; Zoom Range – 4.2X Varifocal; Multiple Simultaneous Stream; Streams First Stream : Full Hd, 1~30Fps; 1280X720, 1~30 Fps; 704X576, 1-30Fps, Second Stream 704X576, 1~30Fps; 352X288 10~30Fps; Video Compression 32 Kbps ~ 16 Mbps, Support Cbr/Vbr; H.264 Version 3, High Profile Encoding And Motion Jpeg Format Support; 1920(W) X 1080(H) Or Higher Active Pixels; Built-In Ir With 2 Or More Epled; Sw Supported Digital Wdr ; Auto Blc; Sd Memory Slot Upto 32Gb Class 10; Minimum Illumination Icr Colour 0.1 Lux (F1.2 Agc On) B/W 0.001 Lux (F2 Agc On); Shutter Speed 1/25-1/10,000S ; Multiple Resolution 4Cif(704X576), Cif (352X288); 12Vdc / 24Vac / Ieee802.3Af Poe (Rj-45) Support; Supporting All Network Protocols (List The Supporting Protocols); 10/100 Base-T, I/O Audio Support, Audio Compression G.711; Multi-Level User Access With Password Protection; Ip Address Filtering; Https Encrypted Data Transmission; Ieee 802.1X Port-Based Authentication For Network Protection; Ip Address Filtering Https Encrypted Data Transmission; Operating Temperature -10 Deg C To +55Deg C,Onvif Compliant, 36 Months Comprehensive Warranty. Ce, Fcc, Emc & Rohs Certification; And Ul Certification For Core Adaptor Are Mandatory; Onvif Complaint Make: Cp-Plus/Cp-Unc-Tb21zl6s-Vmds27125/Panasonic/Pi-Spw 201Dl/Bosch/ Nti 50022-A3s. Integration Of Cctv System To The Central Server Unified Command Centre Solution Platform (Uccs) At District Police Headquarters Command Center(Dphcc) In Coordination With The Police Department / Designated Agencyand Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work , Supply And Installation Of 32 Channel Network Video Recorder(Nvr) : Supply, Installation, Testing And Commissioning Of 32Ch Embedded 4K Nvr 4Sata Expandable Up To 40Tb, Audio Input & Output, Two Way Communication Supported, G7.11 Audio Format Support, 320Mb Recording Throughput, 16 Alarm Inputs & 4 Outputs, Rs485, Esata And Rs232 To Be Supported With Maximum 16 Users, Op. Temp -10 To 50 Deg. C, Ndaa Compliant, Ul/Ce/Fcc Certified, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes: Cp-Plus/Panasonic/Pi-Spw 201Dl/Bosch/ Octavision/Hikvision. , Supply And Installation Of Wallmounting Network Rack Supplyand Fixing Of 6 U Wallmounting Network Rack With Power Spike Including All Accessories Etc., Complete. And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make:Hcl / Vall , Supply And Installation Of 8Port Poe Switch Supply & Fixing Of Small Business 8 Port Gigabit Poe Managed Switch, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work. Make:Netgear/Dlink , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements. Specification: Lan Cable Cat -6 Utp Cable And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes : D Link / Amp / Molex / Legrand / Krone, , Supply And Installation Of Safety Equipment: As Per Project/Customer Requirements. Specification: Hard Disk 8 Tb And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes : Segate/ Sv-35/Toshiba. , Supply And Installation Of Air Conditioner A/C 2.0 Tonne A/C With Low Power Drive Module.Supply And Transportation Of Inverter Model Cool Type Split Ac Unitwith High Wall Mounted Single Split 100% Copper Indoor And Outdoor Condencing Unit Hermetically Sealed Compressor Suitable For Operation On 230V, 50Hz, 1Phase Ac Supply Capable Of Performing Heat Cool Dehumidifying Air Circulating And Filtering With Cooling And Condensing Units With 3.0 Mts Of Copper Piping, Insulation Kit And 4 Mts Of 4 Core Copper Flexible Chord (Voltage Range 160- 264 Volts) And Cordless Remote Control With Warranty Of Compressor For 5 Years And Comprehensive Maintenance For 2 Years2.0 / 1.8 Tr 5 Star Capable Of Delivering 21600 Btu/Hr And Above With Operating On Refrigerant R-32 / R-410 And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Makes: Daikin / Toshibha / Carrier / Blue Star / Hitachi Or Equivalent , Supply And Installation Of Computers: Core-I7 10Th Gen Processor, 8Gb Ram, 1Tb Hdd, Windows 10 Pro. Specification: General :Wired Usb Keyboard & Optical Scroll Mouse 1 X Ps/2 Combo Port 2 X Usb 3.2 Gen 1 Ports 6 X Usb2.0 Ports 1 X Rj-45 Port 1 X Hdmi Port 1 X Vga Port 1 X Audio Port (Line Out/Line In/Mic In) 1 X Pci Express X16 Gen 3.0 Slot 1 X Pci Express X1 Gen 2.0 Slot 1 X Audio Port (Line Out/Line In/Mic In) 450W 19V/0.84A 80Mm X 310Mm X 395Mm 510Mm X 360Mm X 182Mm 12.5 Kg (Total Pc) Ce, Rohs Table Top 3 Years Warranty Cpu, Monitor, Keyboard & Mouse, User Manual, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make , Supply And Installation Of Ups 10 Kva System (8 Kwatt ) Specification:Input Voltage 80 / 400 / 415 Vac; 3 Phase, Ninput Voltage Range ± 15%Input Frequency 50 / 60 Hzinput Frequency Range ± 10%Input Power Factor > 0,85Output Power Factor 0,8Output Voltage 380 / 400 / 415 Vac; 3 Phase, Noutput Frequency 50 Hz / 60 Hz (Selectable)Battery Type No Maintenance Batterybattery Unit 30Charge Voltage 405 Vdcbattery Charge Time 8 Hours To 90% Capacity After Deep Dischargebattery Test Automatic And Manuel Battery Test Systemover Load Capacity 100% ~ 125% Load 10 Minutes; 125% ~ 150% Load 1 Minute; > 150% Load On The Bypassdimension Wxhxd (Mm) 490 X 1200 X 680Weight ~ 240 Kg., And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make , Supply And Installation Of Generator (20Kva Dg Set) Specification: Power: 20 Kva (16Kw) Fuel Consumption (At 100% Load): 5.09 Ltrs/Hr Fuel Tank Capacity: 63 Ltrs Phase: 3 Phase Dry Weight (Kg): 720 Frequency: 50 Hz Engine: 2 Cylinder, In-Line 4 Stroke, Radiator Cooled Engine, Electrical Starter Motor With Soft Start Engagement Feature, Battery Charging Alternator. 1 X 12 V Dc Battery, And Including Cost And Conveyance Of All Material,Labour Charges For All Operations, Hire And Operational Charges, Incidental Charges, Excise Duty & Customs Duty If Any Applicable, All Taxes But Excluding Gst Etc., Complete For Finished Item Of Work Make/Model: Standard Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
39.
Housing Urban and Rular Development #10452608 Price Bid
Tender For Supply Installation Testing Commissioning Of Fire Detection And Fire Fighting System Work In Simulator Block And Firing Rang For Ncc Campus Jln Marg Jaipur -Supplying, Installation, Testing & Commissioning Ofelectrical Driven Fire Fighting Duty Terrace Pump As Per Tac Andis 12469-1988., Factory Assembledin Pump Make Oemsuitable For Automatic Operation And Consisting Of Following Details Given Asa, B, C, D, E, F, G And H. 2 ( A ) Horizontal End Suction Centrifugal Back Pull Type Pump Complete For Delivery Of Below Mentioned Discharge And Head 3 ( B ) Material Of Construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - Ss 410, Packing - Mechanical Seal 4 ( C ) Squirrel Cage Induction Motor ( Ie-3 Class ) Suitable For 3 Phase, 415 V, 50 Hz, Ac Supply , Class -F Insulation, Synchronous Speed Not Exceeding 3000 Rpm, T.E.F.C Confirming To Ip:55 , Of Required Hp Suitable For The Above Pump , Along With Flexible ( Love Joy Type ) Coupling , Coupling Guard Complete In All Respect . 5 ( D ) Common Bed Plate Fabricated Frommild Steel Channel For Installation Of Pump And Motor Including Anti Vibration Pads. 6 ( E ) The Hydrostatic Tests ( 2 Times Of Design Operating Head Or 1.5 Times The Shut Off Head Whichever Is Higher ) And Performance Tests ( To Determine Developed Head, Pump Bhp And Efficiency V / S Flow ) Of Pumps Along With Trip Test Shall Be Carried Out At Manufacturer’S Works In Virtual / Physical Presence Of Department’S Representatives. 7 ( F ) Physical & Chemical Test Reports Of I ) Pump Casing ( Ii ) Impeller ( Iii ) Shaft ( Iv ) Shaft Sleeveand Dynamic Balance Certificate Is To Be Submitted By Oem 8 ( G ) Suitable Size Reinforced Cementconcreat ( M-30 ) Foundation With Foundation Bolt, Nozing Angle Of Size 40Mm X40mm X5 Mm ( Cost Of Rcc Foundation To Be Paid Extra ) 9 ( H ) Weather Proof Hood Fabricated From 5Mm Thick Uv Stablised Frp Sheet Supported By 50 Mm X 50 Mm X 5 Mm Angle Iron Fram Above Pumpset To Protect It From Weather All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 10 900 Lpm With 35 Mtr Head 11 Providing, Fixing, Jointing, Testing & Commissioning Of Heavy Duty Ms C Class ( Heavy ) Pipes Conforming To Is 3589 / 1239 Part-I For Hydrant And Sprinkler Applicationsincluding Cutting, Screwing, Welding Etc. & Forged Steel Fittings Like Elbows, Tees, Tapers, Reducer, Gaskets Etc. Fixing The Pipe On The Wall / Ceiling With Suitable Clamps, Hanger And Nuts Bolts Including Cutting Hole And Chase In Brick Or Rcc Walls / Slab And Making Good The Same. Complete With Painting Of One Coats Of Red Oxide And Two Or More Coats Of Synthetic Enamel Paint Of Requiredshade Complete As Required. ( Pipe To Be Tested @ 10Kgf / Sqcm For 2 Hrs. ) . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 12 25 Mm Dia 13 32 Mm Dia 14 40Mm Dia 15 50Mm Dia 16 80 Mm Dia 17 100 Mm Dia 18 Supplying And Fixing Of Pn 16 Flanged Y Strainer Fabricated Out Of Cast Iron Body, Ss 304 Strainer With Perforated Screen With 3 Mm. Dia Holesin Existing Ms / Gi Pipe Complete With 2 No. Matching Flanges ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets Etc As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 19 100 Mm Dia 20 Supplying And Fixing Of Pn 16 Cast Iron Dual Plate Wafer Type Check Valve / Non Return Valve With Ss / Bronze Flap Complete With 2 No. Matching Flanges ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 21 100 Mm Dia 22 Supplying And Fixing Of Pn 1.6Butterfly Valve ( Wafer Type ) With S.G Iron Disc And Confirming To Is:13095 Complete With 2 No. Matching Flanges ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 23 100Mmdia 24 Supplying And Fixing Of Pn 16 Brass / Gm Ball Valves With Screwed End, Ss Ball Including Teflon Tape Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 25 25 Mm Dia. 26 Supplying And Fixing Of Ss 304 Single / Double Headed Oblique Pattern Hydrant Landing Valve ( Internal / External ) With 75 / 100 Mm Dia Flanged Inlet & 63 Mm Dia Instantaneous Type Female Outlet Coupling With Cast Iron Wheel Complete With Abs Cap And Chain And All Accessories As Per Is:5290-93 ( Type-A ) In Cluding Matching Flange ( 14 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 27 Single Headed With 75 Mm Dia. Flanged Inlet 28 Supplying & Fixing Ss-304 Short Branch Pipeconforming To Is: 903:93 Fitted With 20Mm ( Nominal Internal Diameter ) Bore Nozzle, For Projecting Water In Form Of Solid Jet. The Branch Shall Have 63Mm Male Instantaneous Inlet, Suitable For Use With 63 Mm Size Fire Fighting Hoses. H.P. Tested To 21 Kgf / Cm² For 2.5 Minutes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 29 Supplying And Fixing Of Flexible Hose Made With 100% Polyester, Black Epdm Internal Rubber Lining With External Coat Of Synthetic Elastomer ( Is:636, Type-A ) 63 Mm Dia, 15 Mtr. Long Rrl Hose Pipe With Instanteneous Type 63 Mm Dia Ss-304Male And Female Couplings ( Is:903 ) Duly Bound And Riveted To Hose Pipes With Copper Rivets And Ss Wire Etc. As Required.Appropriate Test Certificate / Report With Liable Warranty Of Product / Accessories From Oem Shall Be Submitted. 30 Supplying And Fixing First -Aid Fire Hose Reel Drum Wall Mounted Swinging Type With Ms Construction Powder Painted In Post Office Red, Conforming To Is 884-1985 With Upto Date Amendments, Complete With The Following As Required. ( A ) Thermoplastic / Rubber Hose ( B ) 20 Mmdia Ul, Fm Bronze / Ss Nozzle With 5Mm Orifice ( C ) Drum And Brackets For Fixing The Equipments On Wall. ( D ) Connections From Riser With 20 / 25 Mm Dia Brass / Gm Gate Valves With Screwed End And Conforming To Is:778 Class-1Through Forged Steel Screwed Union & M.S. Pipe. Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 31 With 30 M X 20 Mm Thermoplastic Hose As Per Is:12585 Type-2 And Bursting Pressure 42 Kg / Sqcm 32 Providing & Fixing Stainless Steel Pressure Gauge With Dial Of 150 Mm Dia Size And Range 0 To 20 Kg / Sq.Cmwith 3 / 8 Bsp Bottom Entry , Ball Valve , Ss Syphon Tube All Fittings Etc, Dulycalibrated Before Installation In Mks And Fps Units, Accuracy Level + / - 1% Including Making Drilling In Existing Ms Pipeetc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 33 Sitc Of Ul 10Th Edition / En54 / Vds Certified Microprocessor Based Inteligent, Analogue Addressable, Modular, Expandable Networkableloop Fire Alarm Control Panel With Each Loop Capacity Of Min 125 Detectors Per Loop With Total Of 125 Detectors & Devices With Loop Length Up To 1 Km As Per Nfpa 72 Approval. The Panel Shall Be Able To Give Pin Point Location Of Addressable Units Via The Address Code For Each Unit. The Panel Shall Also Be Able To Automatically Switch Off All Control Switches When-Ever Any Alarm Is Triggered. . The Panel Shall Have 230 + 5 % Volts Power Supply, Automatic Battery Charger 24V, Sealed Lead Acid Maintanence Free Battries Sufficient For 24 Hours Normal Working And Then Be Capable Of Operating The System For 30 Minutes During Emergency Condtion. Loop Interface Cards, Communication Module, Lcd / Led Unit To Indicate Fire / Fault Signal Of Individual Unit, Inbuilt Networking Port ( Both Rs485&Ethernet ) , Serial Port For Printer, Two Supervisory Inputs, Two Position Key Switch And Usb Port For Programming.Including The Cost Of All Accessories Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 34 1 - Loop Panel 35 Sitc Of Pressure Switches Ofpressure Range 3 To 15 Bar For Main, Jockey, Terrace Pumpanddiesel Pumps, Etc. As Required ( Control Cable From Pressure Switch To Panel To Be Paid Extra ) . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 36 Supplying And Fixing Of 750 Mm X 600 Mm X 250 Mm Outdoor Application Fire Hose Cabinet Made Of 1.6 Mm Thick Ms Sheetduly Powder Coated In Red Color Externally And White Internally With 6 Mm Thick Glazeddoors With Expanded Metal 2 Mm Thick Jali Including Necessary Locking Arrangement Suitable To Accommodate 2 Nos 15 Mtr. Long Rrl Hose And 1 No. Branch Pipe On Existing Wall / Angle Iron Frame As Required. ( Cost Of Ms Structure For Mounting Frame Is To Be Paid Extra ) All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 37 Providing And Fixing Of 15 Mm Dia Bronze Quartzoid Bulb Type Sprinkler Headswith Maximum Working Pressure 11.6 Kg / Sqcm And Suitable For 68 Degree Centigrade Rating Standard Response ( Ul Listed ) Chrome Plated Complete In All Respect Of The Following Type. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 38 Pendant / Upright Type 39 Sitc Of Ul 10Th Edition / En54 / Vds Certifiedautomatic Floating Sensitivity Type Analog Addressable Multi Criteria ( Two Optical / Smoke Sensor To Reduce False Alarm ) Detector With Mounting Base & Led Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 40 Sitc Of Ul 10Th Edition / En54 / Vds Certified Addessable Manual Call Point ( Mcp ) With Led / Fire Indication Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 41 Sitc Of Ul 10Th Edition / En54 / Vds Certified Addressable Sounder With Strobe Light, Loop Powered / Direct Powered From Facp With Sound Level 90 Db And Programmablefrom The Panel Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 42 Supplying And Fixing Inlet Breeching Connection Of Ci Body With Gun Metal Male Instantaneous Inlet Couplings With Inbuilt Nrv, Drainage Connection With 50 Mm Brass Gate Valvecomplete With Pvc Blank Cap And Chain As Required For 150Mm Dia Outlet With 1 No. Matching Flange ( Minimum 16 Mm Thick ) , Nuts, Bolts, Washers, Gaskets, Etc As Required Of Following Ways. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 43 2 Way 44 Supplying And Drawing Fire Resistant Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation ( Shielded ) Cables Voltage Grade 300 / 500 V As Per Bs / En 50288-7 In Existingsurface Or Recessed Pvc / Ms Conduit / Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 45 2 X 1.5 Sq.Mm Armoured With Outer Sheath In Red Color 46 Supply & Fixing Of Co2 Type Fire Extinguisher Conforming To Is:15683:2018, Charged With Co2 Gas ( Purity 99.7% Conforming To Is 15222 ) , Powder Coated Internal & External Surface Manganese Steel Isi Marked As Per Is 7285 Cylinder Body , Wheel Type Forged Brass Release Valve Isi Marked As Per Is 3224 With Inbuilt Safety Release Device ( ( Fusible Plug And Rupture Disc Type ) , 1.0 Mtr. Metal Wire Braided Hose Having Minimum Bursting Pressure Of 140 Kgf / Cm2, Horn With Metallic Thread Connection, Qr Code For Product Traceability, Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 47 Capacity 4.5 Kg. 48 Supply & Fixing Of Dry Powder Agent ( As Per Is 4308:2019 ) , Abc Typefire Extinguisher ( Stored Pressure Type ) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 49 4 Kg 50 Supply & Fabrication Steel Structure With Ms Channel / Angle / Joist / Ismb / Sheet Etc. Including Welding, Rivetting, Cutting, Nut & Bolt , One Coat Of Primer & Two Coat Of Enamel Paint Etc. As Requiredcomplete In All Respect. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 51 S&F Following Sizes ( Dia. ) Of Isi Marked ( Is:9537 P - Ii ) Rigid Steel Conduit With Wall Thickness According To Is Specified Along Withisi Marked ( Is:14768 P-Ii 2003 ) Accessories Inrecessed Using Saddles, Clamps, Fasteners, Pvc Bushes, Check Nuts, As Required Includingcutting Jhiris In The Wall And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 52 25 Mm 53 Supply & Fixing Of Ceiling Mounted Ul Listed Clean Agent ( Hfc-236Fa ) , Modular Typefire Extinguisher , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Fixed Bulb With Temerature 68 Deg C, Qr Code For Product Traceability Including Fixing On Ceiling With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 54 5 Kg Capacity
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
40.
Defence #10372375 Price Bid
Tender For Augmentation Of Electric Supply Under Ge Dehradun; 1 Supply And Laying Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Power Cables ( Heavyduty ) With Aluminium Conductor, 11000 Volts Earthed, Grade Cross Sectional Area 120 Sqmm 3 Core 2 Supply And Laying Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Power Cables ( Heavyduty ) With Aluminium Conductor, 11000 Volts Earthed, Grade Cross Sectional Area 95 Sqmm 3 Core 3 Supply, Jointing And Testing Indoor Type Cable End Termination Joint Heat Shrinkable Suitable For Ht 11 Kv Xlpe Cable 50 Sqmm To 95 Sqmm 4 Supply, Jointing And Testing Outdoor Type Cable End Termination Joint Heat Shrinkable Suitable For Ht 11 Kv Xlpe Cable 3 Core 50 Sqmm To 95 Sqmm 5 Supply, Jointing And Testing Indoor Type Cable End Termination Joint Heat Shrinkable Suitable For Ht 11 Kv Xlpe Cable 3 Core 120 -185 Sqmm 6 Supply, Jointing And Testing Outdoor Type Cable End Termination Joint Heat Shrinkable Suitable For Ht 11 Kv Xlpe Cable 3 Core 120 -185 Sqmm 7 M&L For Underground Pneumatic Horizontal Drilling Of Holes ( Hdd ) Under Road, Pavement, Hard Standing As Required Length At Site By Trenchless Technology Using Ultra Sound Technique With Necessary Horizontal Direction Drilling Machine . The Contractor Shall Be Conduct Under Ground Scanning To Detect Existing Ht / Lt Cable Line , Sewage Line, Ofc Cable Etc To Avoid Damage. The Entry / Exist Hole Must Be Large Enough To Fit The Drilling Tool And The Operator In It So They Can Aim The Tool. The Hole Also Must Be Deep Enough That As The Tool Compacts The Ground And The Surface To Be Remain Undisturbed. The Depth Of The Starting Bore Pit Depends On The Type Of The Soil That Is Being Worked In And How Well It Compacts. The Operator Shall Aim The Tool To The Desire Exit Point And Allow It To Perform It Function Creating A Bore Hole Under The Ground Without Disturbing Surfaces. The Operator Also Should Monitor The Surface To Make Sure That, It Is Undisturbed. As The Tool Near To The Exit Point It Is Slowed Down And The Exit Pit Should Be Dug To Locate Both The Tool And The Bore. As The Tool Enters The Exit Pit The Operator Should Choose Either Dig Up The Tool To Retrieve It Or Reverses The Tool Back Into The First Bore Pit To Retrieve It Including Connected Earth Work, Complete All As Specified And Directed. 8 Supply & Laying Ofhigh Density Polyethylene Pipes ( Hdpe ) Of Pressure Rating Hdpe Pipes Pn 6 Size 110Mm ( 4 ) Laid In Trenches For The Protection Of Ht Ug Cable All As Specified And Directed 9 Excavation In Trenches Soft / Loose Soil Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth And Getting Out Excavated Soil / Sand / Unsv Lt Cable For Laying Of Cable And Getting Out. 10 Sand Cushioning And Covering Of Ug Cable Using Crushed Metal Sand In Trenches For Cable Protection All As Specified And Directed. 11 Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cm In Hard / Loose Soil Complete All As Specified And Directed By Engr-In-Charge. 12 Removing Excavated Material Not Exceeding 50 Mtr And Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified. 13 M&L For Laying Reinforced Precast Concrete Cable Cover, Class Hv, Type 1, Flat, Size 300Mmx L80mm X 40Mm To U / G Cable Laid Dry Flat Over The Cable With Width Equal To Length Of The Cable And Abutting Each Other With Gap Between Adjacent Slab Not Exceeding 10Mm Over Under Ground Cable For Cable Protection In Trenches All As Specified And Directed By Engineer-In-Charge. 14 Cutting Existing Road / Hardstand Of Any Type By Using Crow Bar Chisel Uprto Adepthof 30 Cm For Laying Gi Pipe Including Making Good The Surface By Returning Filling Watering Ramming In Layers 150 Mm Thick Pcc 1:2:4 Over 200 Mm Thick Hard Core Of Broken Bricks / Stones Over Returning Filling Watering Ramming In Layers Not Exceeding 25 Cm Thick Complete All As Specified And Directed By Engineer-In-Charge. 15 M&L For Gi Tubing Medium Grade ( Isi Marked ) With All Fitting / Acessories For Protection Of Cable On Pole / Wall And Under Road Crossing Including Clamps, Nut Bolt Etc All As Specified And Directed Ofsize 40Mm Dia 16 Supplying, Installing, Testing And Commissioning Of Indoor Draw-Out With Roll On Floor Type Vacuum Circuit Breaker Panel , Consisting Of 2 Incoming Vcb + 02 Out Going Vcb + 01 Bus Coupler Vcb Rated For 11Kv, 800Amp, Min 25 Ka / 3-Sec, Andbus Pts For Each Bus Section, Confirming To Iec 62271-200, Internal Arc Classified Iac Aflr – Min 25 Ka For 1Sec, Accessibility Class Lsc2b-Pm Class, Comprising Of 800Amp, Continuous Rated Copperbusbars And Droppers, 02 Nos. Rack-In-Rack-Out Handles, Structure Made From Aluzinc / Gi / Crcasheets To Prevent Corrosion And Rusting. The Complete Panel Incl. Ht And Lt Chamber With Frls Wiring Shall Be Manufactured By Approved Oem At Its Own Facility, And Same Will Be Verified Via Stage / Final Inspection.The Switchgear Panel Offered Shall Be An Active Lifecycle Product Of The Oem . Make Of Vacuum Interrupter, Numerical Relay, Cb & Panel Shall Be Same. ( Make: Abb ( Zn1 ) / Siemens Nx- ( Rof ) Air / Schneider ( Pix Rof / L&T ) ) .The Board Shall Consist Of Following Panels:- 17 ( I ) 11Kv, 800Amp, Min 25 Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100 With Roll On Floor Type Vacuum Circuit Breaker Having 03 Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push- Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 24Vdc ) . 18 ( Ii ) Current Transformers 11Kv, 150 / 1 / 1A, Core1: Class 5P10, 5Va, Core2: Class 0.5, 5Va, 3 Nos: 19 ( Iii ) Potential Transformers, Draw-Out Type For Easy Maintenance, 11Kv / Rt3:110V / Rt3, 50Va, Cl.0.5 Withassociated Gun-Type Hrc Fuses And Mcbs For Ht / Lt Isolation - Set Of 03 Nos. The Line Pts In The Incomer Panels Shall Be Floor Mounted Or Roll On Floor Type, It Should Not Be Placed On Top Of The Panel. 20 ( Iv ) Main Protection Relay Shall Be Numerical Ied Relay Confirming To Iec60255, Having 04Ct Inputs Withmicroprocessor Based Protection Scheme For Tripping The Breaker On Various Faults Like ( A ) 3 Over-Current And 1 - Earth-Fault ( B ) Circuit-Breaker-Failure Alarm, ( C ) Scada Competable Communication On Rs 485 Withmodbus Protocol ( D ) Ct Secondary - 1 A / 5 Amp ( E ) Fault Rocord Min 10 Nos ( F ) Aux Voltage - 24 - 240V Ac / Dc ( G ) Output Contact - Min 4 Nos 21 ( V ) Metering Equipment Including:- ( A ) 01No. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shallbe Communicable On Modbus Via Rs485 Port. 22 ( Vi ) Led Indications :- ( A ) Breaker On / Off / Trip / Spring-Charged, ( B ) R-Y-B, ( C ) Dc Available Led With Push-Button ( D ) Ac Supply Fail ( E ) Trip Circuit Healthy 23 ( Vii ) 08-Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Oc Trip, ( B ) Ef Trip ( C ) Trip Circuit Failure, ( D ) Inter-Tripping Fault, ( E ) Pt Fuse Failurethe Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required 24 ( Viii ) Control Equipment Incl. :- ( A ) 01 X Tnc Switch, ( B ) 01 X Local / Remote Switch, ( C ) 01 X Emergency Trip Push Button, ( D ) Mcbs For Ac ( E ) Mcbs For Dc ( F ) Heater Switch With Thermostat - 01No. ( G ) 3-Pin Socket With On / Off Switch - 01No. ( H ) Cfl Lamp With On / Off Switch - 01No. 25 ( Ix ) Flush Mounted Auxillary Protection Relays Incl:- ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, ( C ) Pt Fuse Failure Relay. ( D ) Dc Supervision Scheme 26 ( B ) 02 X Outgoing Panel, Each Comprising Of :- ( I ) 11Kv, 800Amp, Min 25 Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100. Vacuum Circuit Breaker Having 03Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push-Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 24Vdc ) . 27 ( Ii ) Current Transformers 11Kv, 150 / 1 / 1A, Core1: Class 5P10, 5Va, Core2: Class 0.5, 5Va - Set Of 03Nos. 28 ( Iv ) Main Protection Relay Shall Be Numerical Ied Relay Confirming To Iec60255, Having 04Ct Inputs With Microprocessor Based Protection Scheme For Tripping The Breaker On Various Faults Like ( A ) 3 Over-Current & 1 - Earth-Fault ( B ) Ccircuit-Breaker-Failure Alarm, ( C ) Scada Competable Communication On Rs 485 With Modbus Protocol ( D ) Ct Secondary - 1 A / 5 Amp ( E ) Fault Rocord Min 10 Nos ( F ) Aux Voltage - 24 - 240V Ac / Dc ( G ) Output Contact - Min 4 No 29 ( V ) Metering Equipment Including:- ( A ) 01 Nos. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shall Be Communicable On Modbus Via Rs485 Port. 30 ( Vi ) Led Indications - ( A ) Breaker On / Off / Trip / Spring-Charged, ( B ) Trip Circuit Healthy 31 ( Vii ) 08-Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Oc Trip, ( B ) Ef Trip ( C ) Trip Circuit Failure, ( D ) Inter-Tripping Fault, The Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required 32 ( Vii ) Control Equipment Incl. ( A ) 01 X Tnc Switch, ( B ) 01 X Emergency Trip Push Button, ( C ) 01 X Local / Remote Switch, ( D ) Mcbs For Ac / Dc Isolation ( E ) Heater Switch With Thermostat - 01No. ( F ) 3-Pin Socket With On / Off Switch - 01No. ( G ) Cfl Lamp With On / Off Switch - 01No. 33 ( Viii ) Flush Mounted Auxillary Protection Relays Incl. ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, 34 ( C ) 11Kv Bus-Coupler Vcb Panel 35 Same Description As Incomer Panel Except Meters, Current Transformer, Potential Transformer And Protection & Auxiliary Relays : 36 ( D ) The Panel Shall Be Complete With All Allied Items And Accessories, Including:- ( I ) Cost Of Construction Of Foundation As Per Manufacturer Design, Including Foundation Frame ( Supplied By Oem ) , Channels Etc. For Ht Panel As Required At Site Are Deemed To Be Included In The Quoted Rate. ( Ii ) Each Vcb Panel Being Floor-Mounted, Air-Insulated, Fully-Compartmentalizeds The Oem Shall Supervise And Certify The Commissioning / Charging Of Equipment. ( Iii ) Complete Panel Will Shall Be Suitable For Future Intigration Withwith Scada ( Iv ) Foundation Frames Shall Be Inclusive In The Scope Of Supply Of Oem. ( V ) Make Of Vacuum Interrupter, Numerical Relay, Cb & Panel Shall Be Same. 37 Supplying, Installing, Testing And Commissioning Of Indoor Draw-Out With Roll On Floor Type Vacuum Circuit Breaker Panel , Consisting Of 2 Nos Vcboutgoing + 01 Nos Bus Raiserrated For 11Kv, 800Amp, Min 25 Ka / 3-Sec, Andbus Pts For Each Bus Section, Confirming To Iec 62271-200, Internal Arc Classified Iac Aflr – Min 25 Ka For 1Sec, Accessibility Class Lsc2b-Pm Class, Comprising Of 800Amp, Continuous Rated Copperbusbars And Droppers, 02 Nos. Rack-In-Rack-Out Handles, Structure Made From Aluzinc / Gi / Crcasheets To Prevent Corrosion And Rusting. The Complete Panel Incl. Ht And Lt Chamber With Frls Wiring Shall Be Manufactured By Approved Oem At Its Own Facility, And Same Will Be Verified Via Stage / Final Inspection.The Switchgear Panel Offered Shall Be An Active Lifecycle Product Of The Oem ..The Board Shall Consist Of Following Panels:- 38 ( A ) 02 X Outgoing Panel, Each Comprising Of :- ( I ) 11Kv, 800Amp, Min 25 Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100. Vacuum Circuit Breaker Having 03Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push-Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 24Vdc ) . 39 ( Ii ) Current Transformers 11Kv, 150 / 1 / 1A, Core1: Class 5P10, 5Va, Core2: Class 0.5, 5Va - Set Of 03Nos. 40 ( Iii ) Main Protection Relay Shall Be Numerical Ied Relay Confirming To Iec60255, Having 04Ct Inputs With Microprocessor Based Protection Scheme For Tripping The Breaker On Various Faults Like ( A ) 3 Over-Current & 1 - Earth-Fault ( B ) Ccircuit-Breaker-Failure Alarm, ( C ) Scada Competable Communication On Rs 485 With Modbus Protocol ( D ) Ct Secondary - 1 A / 5 Amp ( E ) Fault Rocord Min 10 Nos ( F ) Aux Voltage - 24 - 240V Ac / Dc ( G ) Output Contact - Min 4 No 41 ( Iv ) Metering Equipment Including:- ( A ) 01No. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shall Becommunicable On Modbus Via Rs485 Port. 42 ( V ) Led Indications - ( A ) Breaker On / Off / Trip / Spring-Charged, ( B ) Trip Circuit Healthy 43 ( Vi ) 08-Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Oc Trip, ( B ) Ef Trip ( C ) Trip Circuit Failure, ( D ) Inter-Tripping Fault, The Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required 44 ( Vii ) Control Equipment Incl. ( A ) 01 X Tnc Switch, ( B ) 01 X Emergency Trip Push Button, ( C ) 01 X Local / Remote Switch, ( D ) Mcbs For Ac / Dc Isolation ( E ) Heater Switch With Thermostat - 01No. ( F ) 3-Pin Socket With On / Off Switch - 01No. ( G ) Cfl Lamp With On / Off Switch - 01No. 45 ( Viii ) Flush Mounted Auxillary Protection Relays Incl. ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, 46 ( B ) 11Kv Bus-Raiser 47 With Potential Transformers, Drawnout Type For Easy Maintenance, 11Kv / Rt3:110V / Rt3, 50 Va, Cl0.5 With Associated Gun Type Hrc Fuses And Mcbs For Ht / Lt Isolation - Set 3 Nos 48 ( C ) The Panel Shall Be Complete With All Allied Items And Accessories, Including:- ( I ) Cost Of Construction Of Foundation As Per Manufacturer Design, Including Foundation Frame ( Supplied By Oem ) , Channels Etc. For Ht Panel As Required At Site Are Deemed To Be Included In The Quoted Rate. ( Ii ) Each Vcb Panel Being Floor-Mounted, Air-Insulated, Fully-Compartmentalizeds The Oem Shall Supervise And Certify The Commissioning / Charging Of Equipment. ( Iii ) Complete Panel Will Shall Be Suitable For Future Intigration Withwith Scada ( Iv ) Foundation Frames Shall Be Inclusive In The Scope Of Supply Of Oem. ( V ) Make Of Vacuum Interrupter, Numerical Relay, Cb & Panel Shall Be Same. 49 Note:- ( I ) License Parter, System Integrator, Panel Builder, Half-Panel Is Not Allowed For 11Kvvcb. All Works Shall Be Done At Own Works. ( Ii ) All Items Will Be Transported In Wooden Packaging To Avoid Any Damage. Acceptance Of Material Will Be Discretion Of Ge. Contractor Has To Remove The Material In Case Of Rejection Of Material At No Extra Cost. ( Iii ) Factory Acceptance Test Shall Be Carried Out For11 Kv Ht Vcb. ( Iv ) Fabrication Of Adaptor Panel Incl Alteration / Couple And Matching Bus Bar Required At Site With Existing Panel Is Deemed To Be Included In Quoted Rate.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
Uttarakhand View Result →
41.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
42.
Public Administrative Department #10304588 Price Bid
Work Of Replacement Of Existing Hydraulic System With Energy Efficient Hydro-Pneumatic System At The Main Pump Room In Kem Hospital.- 1 Removing Of Existing 50 Hp Pumps, Including Removing Cable Termination, Cables, Lugs, Fittings, Pipe Connections, Fittings, Nuts Bolts, Washer, Stand, Pads Etc Complete In All Respect And Keeping The Same In The Department Store Area As Directed By Site In Charge 2 Breaking Of Existing Rcc Padestal Of Pumps And Disposal Of The Same For 50-100 Hp Pumps 3 Constructing Rcc Pedestal For Pumps Are Per Drawings, Details And Specifications Etc Complete ( For 3 + 1 Pump Set ) For 25 Hp & 30 Hp Pumps 4 Providing And Fixing In Position G.I. Heavy Grade C Class Pipe Of 200Mm Dia. 5 Supplying & Laying C Class G.I. Pipe ( I.S.I Mark ) For Suction / Delivery Line Etc.: 100 Mm Dia 6 Providing And Fixing In Position G.I. Heavy Grade C Class Pipes 80 Mm 7 Providing And Fixing In Position G.I. Heavy Grade C Class Pipes 50 Mm 8 Providing And Fixing In Position G.I. Heavy Grade C Class Pipes 25 Mm 9 Ci Body Butterfly Valve 200 Dia 10 Ci Body Butterfly Valve 100 Dia 11 Ci Body Butterfly Valve80 Dia 12 Ci Body Butterfly Valve 50 Dia 13 Ci Body Butterfly Valve 40 Dia 14 Ci Body Non Return Valve 200 Dia 15 Ci Body Non Return Valve 80 Dia 16 Ci Foot Valve100 Dia 17 Providing And Fixing Calibrated Pressure Gauge 100Mm Dia With U Tube Syphon And Isolation Cock Including Fixing With Jointing Material Etc Complete. 18 Providing And Fixing In Position Ms Fabricated Brackets / Supports For Fixing The Ci / Pvc Pipes Including Fixing Of Brackets On Wall / Slab / Ceiling As Required With U-Bolts, Nuts And Bolts Etc Complete. 19 Supplying, Installing, Testing And Commissioning Of Priming System ( 3 Hp Submersible Pumpset-2 Nos ) For Priming Of Hydraulic System Pumpset With Electrical Cables, Lugs , Gland, Includingnrv, Gate Valves, Necessary Plumbing , Starter Panels, Pressure Switch Control Wiring Sensorsfor Low / High Water Level, Dry Run Protection, Cable Tray Wihting The Manifold For Power Supply To Pumps From Control Panel For Operation. 20 Supplying, Installing, Testing And Commissioning Of Hydropneumatic System Pumps ( 3 Working + 1 Standby ) Of 30 Hp Capacity Including Its Baseplate, Vibration Isolation Pads, Lifting Hooks, Anchor Fasteners, Etc Complete In All Respect. 21 Providing And Fiing In Position 200Mm Ss 316 Grade Manifold For Suction And Delivery Header With Blank Off Ss 316 Flanges On Both Sides Of The Header Including Ss Nut Bolts, Washers And Rubber Gasket. 22 Supplying, Installing, Testing And Commissioning Of Pre-Charged Diaphragm Pressure Vessel With Interchangeable Membrane, Charging Connection, Connected To Outlet Header With Necessary Flanges, Gaskets, Isolating Valves, Nuts / Bolts Etc. Complete ( Size Of Pressure Vessel Shall Be 500 Liters ( Approx. ) Or As Per Manufacturer Recommendation ) Tank 10 Bar Etc Complete. 23 Supplying, Installing, Testing And Commissioning Of Vfd Operated Electrical Control Panel With Forapprox.25Hp-30Hp Pump With Plc Based System And Works On The Pressure Sensing With Pressure Switch And Water Level Control In Ug And Overhead Tanks, Control Panel For All Vfd Operated Pumps Including Type Ii Coordination For Bypass Arrangement Incase Of Failure Of All Vfds, Electrical Cables, Lugs, Glands And Its Terminations, Feather Touched Led / Lcd Screen Panel For Operation Control Panel Should Have Over Current, Over Voltage, Surge, Earth Leakage And Phase Protection, Bms Compatible For Programming, Plc Based Vfd For The Frequency Control As Per The Demand Flow, Pump Running And Fault And Capable To Communicate With Other Controllers Following Modbus-Rtu Or Bacnet Class-2 Protocol Through Rs485 Port. System Should Be Capable To Compensate For Frictional Losses At Lower Flows. All Alarms Should Be Displayed In The Controller. System Should Be Equipped With Dry Running Protection Etc Complete In All Respect. 24 Supplying, Installing, Testing And Commissioning Of Float Sensors In Ug Tank For Non Operation Of Pumps During Low Water Level 25 Providing And Fixing In Position Gun Metal Heavy Duty Air Relies Valve Hawa Make Conforming To Is 778 With Screwed Female Endincluding Testing And Commissioning. Etc Complete. 26 1St Category Cu Armoured Cables Frlsz Outer Sheathed- 3.5C X50 Sq.Mm 27 Cable End Termination For Copper Cables – 3.5C X 50 Sq.Mm 28 Earthing Continuity Conductors -Bare G.I. Conductor Size 10 Swg 29 G.I. Trunking / Duct / Raceway & All Other Accessories – 300 X 40Mm ( W X H ) - ( 14 Swg – 2Mm ) With Cover Without Partition 30 Supply, Installation, Testing & Commissioning Of Pressure Switch To Actuate ( `Cut-Off And / Or `Make Contact As Required ) At Pre-Set Pressures With All Necessary Fitting, Adapters And Teflon Tape Fixing Etc Complete. 31 Supply, Installation, Testing & Commissioning Of 50Mm Dia Imported Float Valve To Operate At A Pressure Of 2.5Kg / Cm2 To Be Fixed In Each Overhead Tank Outlet To Function Closing When The Tank Reaches The Maximum Water Level With Inlet And Outlet Connections Etc Complete. 32 Sitc Of Ss Single Flanged Flexible Rubber Connector Of200 Dia 33 Sitc Of Ss Single Flanged Flexible Rubber Connector Of100 Dia 34 1St Category Cu Armoured Cables Frlsz Outer Sheathed- 3C X2.5 Sq.Mm 35 Supply And Fixing Of Tinned Plated Copper Lugs For 3Core 2.5 Sq. Mm. Copper Cable 36 1St Category Cu Armoured Cables Frls Outer Sheathed- 4C X 1.5Sq.Mm 37 Earthing Station With 600 Mm X 600 Mm X 6 Mm Galvanised Iron Plate & 50 Mm Dia. G.I. Pipe, 3000Mm Long Gi Pipe ( Class B Or Better ) Earth Pit As Per Is 3043. The Earth Pit Shall Be Provided With Watering Pipe ( Class B ) With Wire Messed Funnel, 25X3 Gi Strip / / 2X8swg G.I. Wire Up To Chamber ( Wire Or Strip Size As Per Fault Level ) , Disconnecting Links With 600 X 600 Mm ( Clear ) Rcc Chamber & Heavy Duty 3Mm Thick Ci Chequered Plate Cover With Hinge & Stainless Steel Bolts. Bentonite / Charcol & Salt Shall Be Provided For Earth Pits. Excavation, Back Filling, Removal Of Excess Soil Is Included In The Scope 38 Earthing Continuity Conductors -25 X 3Mm Gi 39 2Nd Year Csmc Cost ( After 1 Year Dlp ) 40 3Rd Year Csmc Cost 41 4Th Year Csmc Cost 42 5Th Year Csmc Cost
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
43.
Information and Broadcasting #10302301 Price Bid
Providing Theatre Un-Interrupted Power Supply (Ups) For Two Screens At Payyanur, Kannur District- 1 1 UPS and ACCESSORIES 2 od172629/2024_20255 kVA UPS(4K Projector) SITC of 5 kVA,single phase input,single Phase output, true on-line UPSSystem with 30 minutes back up , with isolation transformer, voltage stabilizer including all accessories,SMF batteries VRLA type with powder coated CRCA cabinet including all accessories cabling etc asrequired complete having following specification. RS485 Interface compatibility Fully digital controlledbased on DSP Power factor corrected from end > 0.9 Pure sine wave output. Regulated output voltage &frequency. Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypassswitch / manual by pass switch Auto temperature compensation, Remote Management Interphase, Backup time 30 minutes at full load. The system shall have 2 years warranty for UPS and batteries,including rack and interconnecting cables. The UPS will provide 30 minutes of backup using a SealedMaintenance-Free (SMF) battery from a reputable, approved manufacturer, with the required Amp-Hour(AH) rating, supported by calculations..The cabling between UPS and Batteries shall be in the scope ofContractor. 3 od172630/2024_202520 kVA UPS(For Sound System) Supply, Installation, Testing and Commissioning of 20 kVA, Threephase input, Single Phase output, High Performance IGBT/PWM based True-On-Line Double ConversionUPS system with Isolation transformer and 30 minutes back up including SMF batteries VRLA type withpowder coated CRCA cabinet including all accessories and cabling etc as required complete havingfollowing specification. The UPS system consist of one numbers of UPS unit and one set of battery bank,Fully digital controlled based on DSP, Power factor corrected from end > 0.95 ,Input THDi <3%, Puresine wave output. ECO Mode for efficiency up to 98%,Full time output voltage & frequency regulation,Auto regulation of battery end voltage Intelligent interface with LED/LCD display, Static bypass switch,manual by pass switch Auto temperature compensation, Remote Management Interphase, testing as pervarious load conditions shall be done at site to establish the supplied item is complying thespecifications. >The system shall have 2 years warranty for UPS and batteries, including rackand interconnecting cables. The UPS will provide 30 minutes of backup using a Sealed Maintenance-Free (SMF) battery from a reputable, approved manufacturer, with the required Amp-Hour (AH) rating,supported by calculations. The cabling between UPS and Batteries shall be in the scope of Contractor.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
44.
Information and Broadcasting #10302297 Price Bid
Re-E Tender For Providing Theatre Un-Inteterrupted Power Supply (Ups) For Two Screens At Vaikkom, Kottayam District- 1 1 UPS and ACCESSORIES 2 od172629/2024_20255 kVA UPS(4K Projector) SITC of 5 kVA,single phase input,single Phase output, true on-line UPSSystem with 30 minutes back up , with isolation transformer, voltage stabilizer including all accessories,SMF batteries VRLA type with powder coated CRCA cabinet including all accessories cabling etc asrequired complete having following specification. RS485 Interface compatibility Fully digital controlledbased on DSP Power factor corrected from end > 0.9 Pure sine wave output. Regulated output voltage &frequency. Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypassswitch / manual by pass switch Auto temperature compensation, Remote Management Interphase, Backup time 30 minutes at full load. The system shall have 2 years warranty for UPS and batteries,including rack and interconnecting cables. The UPS will provide 30 minutes of backup using a SealedMaintenance-Free (SMF) battery from a reputable, approved manufacturer, with the required Amp-Hour(AH) rating, supported by calculations..The cabling between UPS and Batteries shall be in the scope ofContractor. 3 od172630/2024_202520 kVA UPS(For Sound System) Supply, Installation, Testing and Commissioning of 20 kVA, Threephase input, Single Phase output, High Performance IGBT/PWM based True-On-Line Double ConversionUPS system with Isolation transformer and 30 minutes back up including SMF batteries VRLA type withpowder coated CRCA cabinet including all accessories and cabling etc as required complete havingfollowing specification. The UPS system consist of one numbers of UPS unit and one set of battery bank,Fully digital controlled based on DSP, Power factor corrected from end > 0.95 ,Input THDi <3%, Puresine wave output. ECO Mode for efficiency up to 98%,Full time output voltage & frequency regulation,Auto regulation of battery end voltage Intelligent interface with LED/LCD display, Static bypass switch,manual by pass switch Auto temperature compensation, Remote Management Interphase, testing as pervarious load conditions shall be done at site to establish the supplied item is complying thespecifications. >The system shall have 2 years warranty for UPS and batteries, including rackand interconnecting cables. The UPS will provide 30 minutes of backup using a Sealed Maintenance-Free (SMF) battery from a reputable, approved manufacturer, with the required Amp-Hour (AH) rating,supported by calculations. The cabling between UPS and Batteries shall be in the scope of Contractor.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
45.
Public Administrative Department #10291319 Price Bid
Tender For Provision Of Ac,Cctv ,Online Ups, Water Cooler & Allied Works At M&Cw Nangloi Upgraded To Aamin Ward No.36 Under Narela Zone.; 1 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable and 1.5 sq.mm. FR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group C 2 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.3 x 4 sq. mm 4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a)5/6 Amp Switch 5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 3 pin 5/6 Amp modular socket outlet 6 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6Module (200mmX75mm) 7 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) 8 Supplying and fixing suitable size GI box with modular plate and cover in front on surface / recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connections etc. as required. 9 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20MM 10 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25MM 11 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single Pole 12 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.DoublePole 13 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 14 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a)12 way Double Door 15 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. 16 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 17 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 18 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. asrequired. Up to 450 mm Sweep 19 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm 20 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surfaceas required.Up to 35 sq.mm ( Clamped with 1 mm thick saddle ) 21 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 22 Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate up to 50 0C (out door ambient temperature).(a)1.5 TR with fixed speed 5 Star BEE rating (Non inverter type) 23 S/I/T/C of 3 core, 4 Sqmm. Electrical wire for Air conditioner. 24 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 25 S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V 26 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 2*1.0 sq mm 27 Supply of 12 ( 300 mm )sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required. 28 Supplying and fixing of full stainless steel body self-contained drinking water cooler with cooling capacity 150ltr per hr, storage capacity 150ltr and suitable for 230V supply as required. 29 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1.20mm)a) 18- 22 watt 30 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req (a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 31 Supplying, installation, Testing & Commissioning of Flood Light,powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage:Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tiltable fitting, life time (LED,Driver & electrical circuitry) of minimum 50000Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulatedcopper conductor single core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).50 watt 32 P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd. 33 Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable 1.1 KV grade confirming to IS 7098as required. (a) 2 x 6 sq mm 34 Online UPS - Input supply: Single Phase, Output Supply : Single Phase Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. (B) 2KVA 35 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required (B) two run of cable 36 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(a) One Run of Cable 37 SITC of 4MP fixed lens Dome IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 s Frame Rate: 1-20 fps or better ** Lens: 2.8mm fixed Video Compression: H.265 or better ** S/N Ratio: >45dB Resolution: (2650x1440) or better ** Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE, DDNS, IEEE802.1X IR Range: Minimum 25mOperating Temperature: -30 to 50 deg Cent Weatherproof Standard:IP66 or better ** Safety standard: UL 38 SITC of 4MP fixed lens Bullet IP Camera with following specifications:- Image Sensor: 1/3 4MP CMOS or better** Minimum Illumination: 0.08 lux color, 0 lux with IR or better** Shutter Speed:1/3 - 1/100,000 s Frame Rate: 1-20 fps or better** S/N ratio: >45 dB Lens: 2.8mm fixed Video Compression: H.265 or better** Resolution: (2650x1440) or better** Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1X IR Range: Minimum 30m Operating Temperature: -30 to 50 deg Cent Weatherproof Standard: IP66 or better** Safety standard: UL 39 SITC of 8 channel NVR with the following specifications:Camera resolution:upto 8MPInterface: 1 HDMI, 1VGA minimum,Compression :H.265or better Network Throughput :80Mbps or better**, USB Port: 2 USB port (USB2.0)minimum Hard disk interface: 1 SATA port suitable for 6TB each, Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS , Operating temp: -10 to 55 deg CentSafety standard: UL 40 SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch 41 SITC of full HD LED Monitor,32 INCHES complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 300 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz at sitewith connections andalong with all accessories etc.Complete as required. 42 SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.8 U 43 SITC of 4 TB surveillance HDD 44 SITC of singlephase monoblock pump set complete with all accessorie workable on 240/ 415 volts ,50Hz ac supply (a)1 HP singlephase monoblock pump set,head from 12-30 metre suction and delivery25X25 mm. 45 Supply,Installation, Testing & Commissioning of portable type CO2 fire extinguisher of 4.5 Kgs capacity completely charged complete with release valve, discharge horn/pipe locking arrangement, wall mounted bracket with screw and sleeve confirming to relevant IS. 46 P&F 4 kg capacity Dry powder ABC type (stored pressure) completely charged fire extinguisher complete with pressure gauge, release valve, discharge horn/pipe locking arrangement, wall mounted bracket with screw and sleeve confirming to relevant IS. 47 Comprehnsive Annual Maintenance contract of existing camera as inclusive all of above (CCTV cameras, NVR, complete with all accessories ) all after one year ofdefect liabilty period i/c replaacement of damaged item/part/system with all accessories, spare parts, software, handware etc as required. 2nd year 48 Comprehnsive Annual Maintenance contract of existing camera as inclusive all of above (CCTV cameras, NVR, complete with all accessories ) all after one year of defect liabilty period i/c replaacement of damaged item/part/system with all accessories, spare parts, software, handware etc as required. 3rd year 49 Comprehnsive Annual Maintenance contract of existing camera as inclusive all of above (CCTV cameras, NVR, complete with all accessories ) all after one year of defect liabilty period i/c replaacement of damaged item/part/system with all accessories, spare parts, software, handware etc as required. 4th year 50 Lifting of existing submersible pump set with all accessories from well and lowering the same along with all assessories for the depth Up to 50 meter complete as reqd. 51 Rewinding of single / three phase AC motors of vertical type multi stage submersible pump sets of following rating :- (a) Single phase 1.5 HP 52 Repairing of pumping unit of 1/1.5/3 HP vertical type multi stage, submersible pump setby replacement of following accessories/parts etc. Complete as reqd. (a) Gun metal bush / bearing. 53 (b) Pump Shaft 54 (c ) Impeller 55 Development of tube well with suitable capacity of air compressor i/c lowering of the necessaryinduction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when gravel stop sinking discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd. 56 P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. (a) 3 X 2.5 sq.mm.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
46.
Drinking Water Supply and Sanitation #10084992 Price Bid
Scada System For Srbc Kc Canal Tgp Supply, Installation, Testing, Commissioning, Training, Operation And Maintenance Of Scada System ( Automation Of Gate Operations ) For Head Regulators Of Srisailam Right Bank Canal ( Srbc ) , Kurnool-Kadapa Canal ( Kc Canal ) And Telugu Ganga Canal System , Local Control System , Supply Of Remote Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs And Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including Necessary Surge Protection With 7” Or Above Hmi Display And Industrial Type Electrical Fitting And Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification , Supply Of Shaft Encoder Based Rotary Position Sensor With Digital Display Type Gate Position Sensors For Indication And Monitoring Of Canal Gates, Including Cabling And Integration With Plc / Rtu / As Per Technical Specifications. , Supply Of Automated Water Level Transmitter Non-Contact Radar / Ultrasonic Type Having 8 M Range For Measuring Level / Downstream Discharge In Canal Across The Head / Cross Regulators, Including All Necessary Mast / Cantilever As Per Technical Specification. , Supply Of 3 Phase Vfd Starter Panel For Each Motor Of Barrage Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. , Supply Of Side Looking Acoustic Doppler Based Velocity Meter ( Advm ) For Direct Downstream Discharge Measurement In Head / Cross Regulators Canal System With Bed Width Of As Per The Site Required, Including Integration With Plc / Rtu Complete As Per Technical , Supply Of Automated Water Level Transmitter Non-Contact Radar Type Having 30M Range For Measuring Upstream Level On Head Regulators Of Sunkesula Barrage, Tgp Link Channel & Bcr Additional Head Regulator, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specification , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit & Mounting Accessories For Power Back Up To Remote Plc / Rtu As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Color Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24- Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, And Communication With Scada Control Room Complete As Per Technical Specifications. . , Control Room Equipment’S , Supply, Engineering And Development Of Customized Scada Software For Head / Cross Regulator Automation With Life Time Licensed Version As Per Technical Specifications , Supply Of Industrial Grade Server Which Includes Server With Work Station Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete For Canal Network, As Per Technical Specifications. , Supply Of Industrial Grade Computer Node As Workstation Along With 42 Inch Led Display, 1 Kva Ups & 4G / 3G Dongles / Broadbandat Division Monitoring Station With Necessary Accessories As Per Technical Specifications , Supply Of Internet Connection And It Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Color Printer As Per Technical Specifications. , Supply Of 55” Smart Led Display System For Monitoring Of Canal System At Canal Scada Control Room, As Per Technical Specifications. , Supply Of Laptops & 4G / 3G Internet Dongles Along With Licensed Version Of Client Scada Software For Remote Viewing & Monitoring Of Canal Automation As Per Technical Specifications , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Canal Scada Control Room Equipment’S As Per The Technical Specifications. , Supply Of Diesel Generator Set 10 Kva With 04 Earth Pits For Earthing At Canal Scada Control Room , Supply Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Control Room For Establishment Of Canal Scada Control Room Along With Necessary Electrical Fittings As Per Technical Specification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Andhra Pradesh View Result →
47.
Drinking Water Supply and Sanitation #10079997 Price Bid
Supply, Installation, Testing, Commissioning, Training, Operation And Maintenance Of Of Scada Based Canal Automation For Nagarjun Sagar Right Main Canal Project, Andhra Pradesh Under National Hydrology Project ( Nhp ) Supply, Installation, Testing, Commissioning, Training, Operation And Maintenance Of Of Scada Based Canal Automation For Nagarjun Sagar Right Main Canal Project, Andhra Pradesh Under National Hydrology Project ( Nhp ) , 1 ) Goods As Per Shedule Of Requirements -Local Control System For Nsp Right Main Canal System , Supply Of Remote Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs And Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including Necessary Surge Protection With 7” Or Above Hmi Display And Industrial Type Electrical Fitting And Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification. , Supply Of Shaft Encoder Based Rotary Position Sensor With Digital Display Type Gate Position Sensors For Indication And Monitoring Of Canal Gates, Including Cabling And Integration With Plc / Rtu / Datalogger As Per Technical Specifications. , Supply Of Automated Water Level Transmitter Non-Contact Ultrasonic Type Having 10 M Range For Measuring Level / Downstream Discharge In Canal Across The Head / Cross Regulators, Including All Necessary Mast / Cantilever As Per Technical Specification. , Supply Of Side Looking Acoustic Doppler Based Velocity Meter ( Advm ) For Direct Downstream Discharge Measurement In Head / Cross Regulators Of Nsp Canal System With Bed Width Of As Per The Site Required, Including Integration With Plc / Rtu / Datalogger Complete As Per Technical Specifications. , Supply Of Datalogger / Rtu With 2 Channel And Rs485 Port For Sensor Input Type With Gsm And Gprs Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission From Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Datalogger / Rtu With 8 Channel And Rs485 Port For Sensor Input Type With Gsm And Gprs Based Telemetry & Enclosure Including Antenna And All Necessary Equipment For Data Transmission From Remote Monitoring Stations, As Per Technical Specifications. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit & Mounting Accessories For Power Back Up To Remote Plc / Rtu / Datalogger As Per Technical Specifications. , Supply Of Battery-Operated Water Level Monitoring System Using Non-Contact Ultrasonic / Radar Type Water Level Sensor With Gprs / Gsm Communication System For Canals Having Measurement Range Of 0-6 M, Along With Other Ancillary Equipment And All Necessary Mounting Hardware, As Per Technical Specifications. , Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Colour Camera. 6 Or 8 Or 12Mm ( According To Site Supply Of Lte Surveillance Ip Based 3G / 4G Bullet Camera With Sim Card Slot, 2 Mega Pixel 2 Or4 Array / 72 Led Colour Camera. 6 Or 8 Or 12Mm ( According To Site Suitability ) With Storage Facility Of At Least 24- Hour Video Recording, In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation Complete As Per Technical Specifications. , Supply & Erection Of Pre-Fabricated Green Hut ( Hutment ) ( Size 6X6 And 8 Height ) With M.S. Angle 50X5, 16-Gauge M.S. Sheet, Opening Door, Roof And Floor, Painting Etc. Complete. The Base Measuring 7‘X 7‘ ( 6 Inches Thick ) For Pre-Fabricated Green Hut Should Be Constructed Cement Concrete In M 150 Grade As Per Technical Specification. , Control Room Equipment’S , Supply Of Customized Irrigation Monitoring Software Which Shall Include Scada Software For Real Time Monitoring & Controlling Of Canal Operations, Water Scheduling, Real Time Data Logging For Complete Canal System With Life Time Licensed Version. As Per Technical Specifications. , Supply Of Industrial Gradeserver Which Includes Server With Work Station Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete Forcanal System, As Per Technical Specifications. , Supply Of Industrial Grade Computer Node As Workstation Along With 42 Inch Led Display, 1 Kva Ups & 4G / 3G Dongles / Broadband Including Required Software At Division Monitoring Station With Necessary Accessories As Per Technical Specifications , Supply Of Internet Connection Andit Hardware Which Includes Required Static Ip, Router With Modem, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications. , Supply Of 110” Smart Led Display System Including Installation For Monitoring Of Canal System At Canal Scada Control Room, As Per Technical Specifications. , Supply Of Laptops & 4G / 3G Internet Dongles Along With Licensed Version Of Client Scada Software For Remote Viewing & Monitoring Of Barrage Automation As Per Technical Specifications , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Canal Scada Control Room Equipment’S As Per The Technical Specifications. , Supply Of Diesel Generator Set 10 Kva With 04 Earth Pits For Earthing At Canal Scada Control Room. , Supply Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Control Room For Establishment Of Canal Scada Control Room Along With Necessary Electrical Fittings As Per Technical Specification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Andhra Pradesh View Result →
48.
Educational and Research Institute #10058751 Price Bid
Tender For Supply, Installation, Testing And Commissioning Of Hvac And Electrical Works For Establishment Of Drtb Ward At Aiims Rishikesh; 1 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 2 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire 3 Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 5 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 6 Supplying and fixing following rating, four pole 415-volt TPN MCB in the existing MCB DB complete with connections, testing and commissioning etc. as requiredMCB TPN 63-amp, C Curve 7 Once through Double Deck AHU (OAHU - 100% Fresh air & 100% exhaust with heat recovery unit):- Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, Bottom Deck:- consisting 100% fresh air intake provisions with aluminum dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (G-4), fine filter (F-9), with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre-coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 8 row deep DX cooing coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope. UVGI System: - UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHUs for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil. Cross flow type heat exchanger: - The supply and exhaust airflow perpendicular to each other separated by aluminum plates which transfer the heat from one side to the other. Heat transferred from one air flow to another without mixing the air flows. Sensible Efficiency up to 80%. Upper Deck: - consisting 100% exhaust air provisions with aluminum dampers on exhaust air side and return air side, all filters flanged type i.e. pre-filters (G-4), HEPA filter (H-13) sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre-coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch and standard accessories. Supply Air Fan Capacity, CFM: 2400 Return Air Fan Capacity, CFM: 3000 DX Cooling Coil Load, TR: 16 Total Supply side Static, Pa: 1000 Total Return side Static, Pa: 1000 8 Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet 9 Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. 10 Supply, installation, testing and commissioning of air diffusers of powder coated aluminum with aluminum volume control dampers with anti-smudge ring & removable core 11 Supply, installation, testing and commissioning of Fresh / Exhaust air intake louvers made from 3 wide (Minimum 3 MM thickness) powder coated extruded aluminum @ 1 pitch with proper stiffeners complete with HDPE insect mesh fixed in a removable frame as per approved design. 12 Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Fire damper 13 Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Actuator 14 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self-adhesive nitrile rubber tape insulation complete as per specifications and as required.19 mm 15 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self-adhesive nitrile rubber tape insulation complete as per specifications and as required.25 mm 16 Supply, installation, testing and commissioning of 0.63 mm aluminum sheet cladding as required complete in all respect with fixing screws etc., for cladding of outside / exposed ducts. 17 Supply Installation, Testing & Commissioning of modular type Variable Refrigerant flow /Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A/latest Refrigerant, vibration isolators, outdoor unit frame with suitable foundation, complete with all accessories as required etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at approx. 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 complete as per the technical specifications. Capacity: 20 HP 18 Supply Installation, Testing & Commissioning of AHU Kit consists of a control PCB, electronic expansion valve, complete with all accessories as required etc. This kit will connect the AHU to the VRF Outdoor Unit. 19 Supply Installation, Testing & Commissioning of Corded Thermostat cum controller for temperature setting and operation, complete with all accessories as required etc. (Dual mode: Cooling & Heating). 20 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, complete with all accessories as required etc. 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation 21 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, complete with all accessories as required etc. 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation 22 Supply, Installation, testing and commissioning of 40 mm dia nominal bore B class medium duty G.I. pipe conforming to IS 1239 including welding, fittings likes elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. complete in all respect for AHU condensate drain piping with 19 mm thick nitrile rubber insulation, nut-bolts, supports, pipe support block etc. duly installed with 0.63 mm aluminum sheet cladding as required complete in all respect with fixing screws etc. 23 Supply & Installation of Digital Magnehelic gauge with suitable 24 gauge smoothened to 240 grit SS304 face plates & 16-gauge GI Box & PU Tube/ silicon tubing (Range: 30 - 0 - 30 Pa) suitable to install in modular panel with nozzle & complete accessories for clean rooms. 24 Supply, Installation, Testing & Commissioning of Electric tubular finned Heaters of 12 kW capacity in SS construction and bank wise distribution, duly installed in ducts complete with mounting arrangement, safety thermostat, humidistat for humidity control, SSR based control, contactor etc. Heater should be ISI marked. 25 Fabrication, Supply, Installation, Testing, Commissioning of Outdoor floor mount type AHU control Panel with following specifications: CRC Sheet of 3.15 mm, Grey Color with Incoming: 1 Incomer -200 Ampere MCCB/16KA 4 Pole. Panel must include R, Y, B Indicator, with 250 ampere aluminum busbar, 1No Digital Multi-Function Metre / Digital Load Manager suitable to connect with Centre Energy Monitoring System/BMS through RS485 connection. Outgoing: Outgoing -2 Nos with 25 Ampere MCB/16KA 4 Pole for supply motor - 4 kW, exhaust motor - 4 kW. All outgoings shall be with necessary MCBs, contactors, relays, illuminated push button for manual ON & OFF, indication lamps (for ON, OFF, TRIP Status), Auto/Manual selector switch. Outgoing -1 Nos with 63 Ampere MCCB/16KA 4 Pole for VRF outdoor unit. All outgoings shall be with necessary MCBs, contactors, relays, illuminated push button for manual ON & OFF, indication lamps (for ON, OFF, TRIP Status), Auto/Manual selector switch. Outgoing -1 Nos with 40 Ampere MCCB/16KA 4 Pole for heaters - 12 kW (three bank distribution). All outgoings shall be with necessary MCBs, contactors, relays, illuminated push button for manual ON & OFF, indication lamps ( for ON,OFF,TRIP Status), Auto/Manual selector switch. Outgoings with suitable rating MCBs shall be considered for UVGI system, fire damper, AHU limit switch etc. Necessary safety interlocks like AHU motor interlock with service door limit switch, fire damper interlock, supply & exhaust fan interlock, UVGI system and heaters interlocks with AHU). Potential free Contact (for supply motor, exhaust motor, fire damper, heater, humidifier etc.) to be provided for Connections to BMS. Note:- 1. VFD (for motor speed control) with inbuilt PID controller for varying the speed of fan, along with DPT (0 to 3000 pa) sensor for measuring DP across fan and providing input to VFD. VFD to be installed/mounted in motor control panel. Capacity of VFD: 4 kW - 1 No. (for Supply motor) & 4 kW - 1 No. (for exhaust motor) 2. Provision of MCB / Contactor for UVGI system, AHU limit switch, Fire damper etc. to be considered in AHU control panel. 26 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored aluminum cable 3.5 C X 95 sq. mm 27 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 10 sq. mm 28 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 6 sq. mm 29 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 4 sq. mm 30 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.armored copper cable 4 C X 1.5 sq. mm 31 Supply, laying, Testing and Commissioning of following size XLPE insulated armored Cable (Galvanized wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with up to date amendments on surface / cable tray as required and as directed by Engineering in charge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc. armored copper cable 2 C X 1.5 sq. mm 32 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required 150 mm width X 50 mm depth X 1.6 mm thickness 33 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required 100 mm width X 50 mm depth X 1.6 mm thickness 34 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7-metre-long etc. with charcoal/ coke and salt as required.(Set of 2) 35 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 36 Supply and installation of 3 mm thick Aluminum composite panel sheet with necessary support for installation by using screws and silicon sealants in all joints with complete accessories as required etc. for closing the gaps between ducts and civil wall / closing the gap between false ceiling and civil wall.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttarakhand View Result →
49.
Housing Urban and Rular Development #10052526 Price Bid
Implementation Of National E-Vidhan Application (Neva) End-To-End Digital Transformation Of Legislative Assembly. (Sh I- Providing Digital Transformation Facilities At Legislative Assembly) (Sh- Ii Provision Of High Speed Data Networking Poe / Network, Switches Ic Necessary Cabling And Accessories At Legislative Assembly).- 1 (SH:- I Audio Visual System ) 2 SITC of Digital combi Conference Control unit / Server units. Units must be Dante enable (must have minimum 2 Dante/ Network Ports) inbuilt from factorywith Integrated dynamics processor with programmable threshold, ratio, attack, and release of noise gate, AGC and limiter functions/ DSP with adaptive acoustic feedback, echo cancellation, parametric equalizer ( Dante, dynamic processor can be built to the controller/ server or integrated power supply unit) Unit Should have minimum 1 x Power Connectors, minimum 3 x Conference Network Ports or more than 1 x LAN Port, 1 x Balanced XLR audio input or more , 1 x Balanced XLR audio output or more, must be a capable of automatic or manual take-over of the Controller/Server by a spare controller units in case one would become inactive ,in built or external Recording capabilities, Audio Routing, Network Monitoring, Built-in diagnostics application and camera control capability., The Controller should be work on shielded network(non-proprietary) the above ports features can be complied through controller or integrated power supply. Controller Unit should support Voting & Interpretation. 19 Rack Mountable. Controller and server units should be from same OEM. Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR 144 (xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 3 SITC of integrated Power supply cum controller for conference unit with On/Off rocker/ switch with built-in indicator. It should have 48 V, LED indicator or better, Power good TTL output/ LED indicator provided on a sub D9 connector or better RJ 45 ports or Six 3-pin detachable Phoenix connectors are provided at the rear of the Power supply 1U or more to branch off the 48 V. 1U, 19 rack module, Mains power input: 100-240 VAC 60/50 Hz Output voltage: 48 VDC, Protection Short circuit: Overload, Temperature, Over voltage, Technology: Switched Mode Power Supply Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144(xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 4 SITC of one/two or more upstream ports towards the Central Unit. 2 or more powered downstream ports towards the network/ conference field devices. Network Extender cum change over unit extended powering unit supports redundant loop cabling. It shall be possible to daisy chain and loop several network extenders on the conference controller network. It shall be possible to loop Chairman/Delegate units between several network extenders to create redundancy on a network extender level, The Network Extender cum change over unit is powered via the external power unit. Conference OS software application detects possible failure and starts the switch over process accordingly by the operator commands. Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144(xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 5 SITC of Integrated Flush mount Delegate conference unit with Speaker Built-In and with removable microphone capability, supported for Voting and simultaneous Interpretation, microphone push button with integrated LED, Physical / Capacitive 5 clear voting buttons with LED indicators. Should have in build with RFID/ NFC card reader for identification and authentication, Channels selector button with a OLED/ LCD display and headphone volume control, Built-in high- quality loudspeaker, minimum 1W or as per OEM, built in speaker frequency response: 200-15,000 Hz or better, Speaker shall automatically muted/ active when the microphone is active, to prevent acoustic feedback available in custom colours dimension, finishes, construction: steel / metal or as pr OEM, only 3.5 mm stereo jack sockets for headphone connectivity. “Connectivity: › 2 x RJ 45 port (IN/OUT). Loop through, daisy-chain cabling (non-proprietary).USB-C or mini-USB or mini din, Push & Lock/ screw socket to connect the detachable microphone. Microphone Input: › Dynamic range: > 90 dB or better › THD: 0.1% or better.Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144 (xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 6 SITC of Integrated Flush mount Chairman conference unit with Speaker Built-In and with removable microphone capability, supported for Voting and simultaneous Interpretation, microphone push button with integrated LED , Physical / Capacitive 5 clear voting buttons with LED indicators. Should have in build RFID/NFC card reader for identification and authentication, Channels selector button with a OLED/LCD display and headphone volume control, Built-in high-quality loudspeaker, minimum 1W or as per OEM, built in speaker frequency response: 200-15,000 Hz or better, Speaker shall automatically muted/ Active when the microphone is active, to prevent acoustic feedback available in custom colours dimension, finishes, construction: streel / metal or as pr OEM,only 3.5 mm stereo jack sockets for headphone connectivity. “Connectivity: 2 x RJ 45 port (IN/OUT ). › Loop through, daisy-chain cabling (non-proprietary).USB-C Push/ mincon/ mini din& Lock/ screw socket to connect the detachable microphone. Microphone Input: › Dynamic range : > 90 dB or better › THD: 0.1% or better. Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144 (xi) guidelines of purchase manual and complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 7 SITC of Gooseneck Microphone 360 MM or above or as per site requirement must have a single/ dual flex gooseneck microphone (flexible top and lower sections) is equipped with USB C-based / mini-USB/ mini din push and lock/screw connector Polar Pattern: Cardioid/ Uni directional or better Shielded microphone, immune to mobile phone interference. Transducer principle: Back electret (condenser). Frequency response: 125 to 15000 Hz or better. Sensitivity @ 1 kHz/ Nominal input level : -43 dBV/Pa/ 85 dB SPL or better. Maximum SPL @ 1 kHz : 110 dB SPL or better. Signal-to-noise ratio/ Equivalent noise : 15 dB or better. Dynamic range : 90 dB or better. Microphone LED ring configurable with selection of RED and Green colour USB-C/ minicon/ mini din -based microphone connector. Connection: Push & screw /Lock. Certification: CE. The OEM, product and bidder shall not share the common borders with India and adhere to GFR144(xi) guidelines of purchase manual complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 8 SITC of conference software should offer all-in-one software package that simplifies room setup and meeting control. Easy step by step configuration wizard and Room layout configuration for the technician Roles for meeting control: › Operator › Chairperson › Signage Specify available controls for each role and Capability to protect roles with password Create a single meeting template including:› Title › Delegates and seating › Optional badge configuration › Optional external recording of the meeting audio Start a meeting from the template or a new meeting It should Manage speakers from room layout, Manage the speaker list, Manage request list with drag and drop re-ordering capability. It should Start a voting session, Voting question, 2 or 3 options for voting and Public or secret voting It should have Signage for Meeting view with Room layout, speaker list and request list, Voting view with results screen, Dynamically switch between meeting and voting view when voting starts / stops. Consult or save up to 20 meeting reports, The reports contain meeting participants, the recording (if available) and timestamped voting items with overall and individual vote resultsVoting results are visualized in the operator, and chairperson screen, but also the signage screen will toggle to visualize the voting results Whenever a need arises a voting can be started on the fly. The voting gets a description, and it can be defined if it is a public or secret vote. In a meeting template participants can be added by simply typing their name and adding them to their assigned seat. Additionally, an RF-ID card can be assigned, allowing participants to identify themselves by logging into any conference device in the room. 9 SITC of Light weight headphone unit Transducer principle: Dynamic as per OEM Load rating: 20 mW or better Impedance: 32 Ω or more, Sensitivity: 94 dB/mW(+ 3 dB at 1 kHz) or better, as per OEM Frequency range 35/50-15,000 Hz or better, Connector: 3.5 mm stereo jack. complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 10 Supply & Laying of Conference Cable 2 Mtr or as per OEM recommended Cat6 shielded cable with high quality STP end connectors complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 11 Supply & Laying of Conference Cable 20 Mtr or as per OEM recommended Cat6 shielded cable with high quality STP end connectors complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 12 SITC of 6 two-way ceiling/ Surface mount speaker with at-least 0.5 HF driver. The speaker must have frequency range (-10 dB) of 70 Hz – 20 kHz; Sensitivity > 88 dB (1W/1m), delivering Max. Calculated SPL (peak) > 100 dB with continuous power handling 30W @ 100V or less. The speaker should have transformer tapping up to 30W .The speaker cabinet should have at-least 170°conical dispersion pattern complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 13 SITC of 240w mixer amplifier with Inbuilt Bluetooth for audio streaming and supports audio playback from USB pen drive with4 microphone/line inputs, plus music source input and insert feature to use as a pre/power amplifier. It also has optional 2 tone chime generation for input 1 complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 14 Supply, Installation, Testing & Commissioning of open architecture DSP having 12 mic/line level inputs with AEC and phantom power, 8 line level outputs, 4x4 USB audio channel, 8 Digital I/O ports, Dante, minimum 4 x RJ-45 Dante ports, minimum 8 audio files can be stored in in-built storage for playback including pink noise, white noise etc, minimum 16 channel bi-directional digital audio expansion bus, zoom & Microsoft teams certified, sampling rate: 48KHz or better, Ethernet monitoring and control, Front panel main input and output signal presence and clipping LEDs; THD + Noise <0.02% or better; Crosstalk <- 90 dB or better; processor: 64-bit. Certified for Microsoft Teams and Zoom for Audio and Video collaboration complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 15 Supplying and laying of 16 AWG 2-core speaker Cable with 19-strand annealed bare copper conductors; Semi- rigid PVC insulation; Twisted, unshielded; Riser rated PVC jacket; NEC CL3R, CEC CMG, RoHS compliant complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge. 16 Supply, Installation, Testing & Commissioning of AV Quad Core control processor with minimum 1x RS232/RS422/RS485, 1x bidirectional RS232 or more, 2 or more IR/Serial, 4 or more Relay, 4 or more Digital I/O. control AV devices over Ethernet port supporting 10/100/1000Base-T and should support IEEE 802.1X, IPv4, TCP, UDP, DHCP, DNS, HTTPS, NTP, SFTP, SMTP, SNMP, SSH protocols. Should have SDRAM: Min 2GB or more and Flash Memory: Min 8 GB or more. Should have Built-in IR receiver for recording IR commands. Should be Operational in up to 45°C temperature. Should have Regulatory compliance: CE/UL or any equivalent complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 17 Supply, Installation, Testing and Commissioning of 10 Tabletop capacitive touchscreen with 1280x800 resolution and 24-bit color depth, Pixel density 149 PPI; Aspect ratio - 16:10; Brightness- 420 nits; Contrast - 800:1; Viewing angle ±85° horizontal, ±85° vertical; SDRAM- 2GB, Flash- 8 GB; Motion & Lighting sensor- On/off OR Auto/manual; Connectors — 1 x female RJ-45; Data rate: 10/100/1000Base-T, half/full duplex with autodetect; Protocol DHCP, DNS, HTTP, HTTPS, ICMP, IEEE 802.1x, SFTP, SSH, TCP/IP, UDP/IP; Touch panel and control processor should be from same OEM complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 18 Supply, Installation, Testing and Commissioning of 98 4K UHD(3840 X 2160) Slim DLED display, Aspect Ratio 16:9, Brightness 600 Cd/m2 or better, Pixel Pitch 0.5622mm(H) × 0.5622mm(V) or better, Haze 30% or better, Viewing Angle 178°or better, HDMI IN X 3, HDMI Output X 1 ,Audio Output 1 x 3.5mm, USB 2.0 X 1 ,USB 3.0 X 1 ,RS232 X 1, LAN X 2(IN/OUT), USB Type-C X 1, 4GB DDR4 memory, 32GB storage, 24 W in built speaker, 24/7 operation, Operation Temperature:0℃ - 45℃, Operation Humidity: 10% - 90%. complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 19 Supply, installation, testing and commissioning of iPad Pro 13″ (M4): Ultra Retina XDR Display, 1TB, Landscape 12MP Front Camera / 12MP Back Camera, LiDAR Scanner, Wi-Fi 6E, Face ID, All-Day Battery Life, Nano-Texture with app from conference OEM if control of IPAD and running of NIC application is required from the conference server complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site including adaptor for USB C to RJ 45. 20 Supply, Installation, Testing and Commissioning of 4K @ 60 fps PTZ Camera with minimum 30X Optical Zoom, min 100 Presets, simultaneous output through Ethernet, HDMI, 12G-SDI and USB 3.0, Audio In and can be controlled via RS232 & 422 In & Out & IP, -170° ~ +170° Panning angle, -30° ~ +90° Tilting angle. The camera tilting and panning speed should be minimum 300° per second. Should support, SRT, FreeD Protocol, PoE and Virtual USB Driver. OEM should be CE, FCC, RoHS & BIS Certified complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 21 Supply, Installation, Testing and Commissioning of Multi-Functional Multi-Camera Controller Joystick should have all required Control Ports complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 22 Supply, Installation, Testing and Commissioning of 4K Video mixer / Speaker Auto Tracking switcher which canseamlessly integrates with above PTZ cameras and conference microphone systems to automatically capture and switch to close-up views of the person speaking, Supports up to 9 Cameras with Automatic Layout Switching, speaker auto-control setting, including override and FIFO modes, customized conference visuals by adding the logo, background images and text overlay for individual speakers, supports 4CH 4K UHD or up to 9CH Full HD video sources,compatible with network-based H.264 RTMP/RTP/RTSP/SRT, and NDI|HX video sources, Video Outputs : 2 x HDMI, 1 x RJ45, Audio I/O : 2 x 3.5 mm stereo Mic in / out complete as per specifications complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 23 Supply, Installation, Testing and Commissioning of 4K Video Recorder, Up to 2ch 4K UHD or 4ch FHD Video Sources Capturing,Switching, Recording and Live Streaming, Support Dante Audio, NDI|HX and SRT Streaming Protocols, PGM Recording up to 4K UHD 30fps with 2TB Internal Storage, Easily Add Background Images, Overlays and Change Video Layouts in Video Making, Supports Overlay PNG Images with Transparent, Opaque, and in Between, Video Input Interface: HDMI x 2, RJ-45 x 2 (supports IP streaming: up to 4 channels, USB x 3 (UVC), Audio Input Interface : 3.5mm Stereo Mic in, Video Output : HDMI x 1 for loop out, HDMI x 1 for preview, Audio out : 1 x 3.5 mm stereo, Recording Mode : 1 mixed + 4 individual original, Control : RS-232 / LAN complete as per specificationcomplete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 24 Supply and Laying of SDI cable complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 25 Supply, Installation Testing & Commissioning of AV over IP 4K Encoder 4K 60 4:4:4with2 x HDMI and 1 x USB-C input and 1 x HDMI output, Auto Video 4K scaler, Switching between the three inputs can beperformedautomaticallyusing auto-switching (input detect) mode, programmatically via a control system, or through a web browser, HDMI loop- through: display any of the three locally connected sources, standard PoE power (15w or lower), HDMI 2.0 & HDCP 2.2, AES-128/256 Encryption, Audio : Analog Stereo 2- channel, HTTPS Secure API, 802.1x Authentication for Network access control, SSH Network Protocol, , Auto Discover all endpoints on the network, VLAN tagging,LLDP Support, QoS Support, USB 2.0 over IP (KVM), RS- 232 over IP, IR over IP, A single Gigabit LAN Port for PoE Power, 4K UHD Video, Latency not more than 10 ms,High Dynamic range(HDR),futureupgradableto Dante / AES 67 complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 26 Supply , Installation, Testing & Commissioning of Decoder supports 4K UHD over Gigabit Ethernet, Bit Rates 50 to 800 Mbps, Video Codec: JPEG2000 based visually lossless video compression algorithm, supports: 4K60 4:4:4, AES-128 Encryption, 1x HDMI with HDCP 2.2 & Sacling Supports a wide range of resolutions and rates, up to 4K, Streaming protocols include IP, UDP, TCP, IGMP, and IGMP, Built-in videowall function, Auto Video Scaler, Vlan Tagging , Analog to digital Conversion: 24 bit, 48 kHz; Control: USB 2.0 over IP (KVM), RS-232 over IP, and CEC over IP, Compliance: CE, FCC, RoHS, WEEE complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 27 SITC of core network switch 24 port 10 G. Efficient use with, 8 SFP+ ports with 10 Gbit,640 Gbps switching capacity, Web interface, Slim 1/ 2 RU housing, Connections – 8 x SFP+ 10 Gbit, 8 x 10G copper. RJ45, RS232, RJ45 Ethernet, 100-240 VAC, approx. 70W, Redundant power supply complete with all required accessories needed for successful installation and as per direction of Engineer-in-Charge as per requirement of site. 28 Supply, Installation, Testing and Commissioning of network switch — 24x1G PoE+ Stackable Managed Switch with 2x10GBASE-T and 2xSFP+ (550W PSU) 24-port 1000BASE-T (RJ45) PoE+, 2-port 10GBASE-T (RJ45) all independent, 2-port 10GBASE-X (SFP+) all independent, 128Gbps non-blocking fabric across 28 ports • Out-of-band 1G Ethernet Management port • Mini-USB and RJ45 RS232 console ports and USB storage port, Full L3 feature set and non-stop forwarding (NSF) stacking, Full width form factor with one-unit rack mount kit, one modular 550W PSU in first power supply slot,second slot with a blank cover for future PSU expansion complete with all required accessories needed for sucessful installation and as per direction of Engineer-in-Charge as per requirement of site. 29 Supply, Installation, Testing, and Commissioning of 10G SFP+ modules etc as required. 30 Supply and Laying of 6 core single-mode optic fibre cable in existing casing/ conduit / wall etc complete as required. 31 Supply, Installation, Testing, and Commissioning of 6U AV Rack etc as required. 32 Supply, Installation, Testing, and Commissioning of 42U AV Rack etc as required. 33 Supply and Laying 2m HDMI cable etc as required. 34 Supply, Installation, Testing, and Commissioning of fibre cable accessories etc as required. 35 Supply, Installation, Testing, and Commissioning of AV cable and connector etc as required. 36 Supply and Laying of Cat6 Cable in existing casing/ conduit / wall etc complete as required. 37 Supply and install raceway compartment 100/300 mm x 38 mm, 1.6 mm thick, under-floor metal trunking/raceway with all accessories made from hot-dip pre-galvanized metal-coated steel sheet. With other necessary accessories etc as required. 38 Design, Supply, testing & commissioning of telescopic type MS mounting frame, duly powder coated in custom colour, conference table mounting arrangement for holding iPads for Members, including locking arrangement etc. The mount should have Horizontal/vertical suitable for viewing by the members in the house or as per direction of Engineer in Charge. 39 SITC of Redundancy setup This module allows automatic take-over of the Controller/Server by a spare engine in case one would become inactive. Includes an power switch to facilitate automatic startup of spare engine etc as required. 40 SITC of 20W 2 way column speaker, 3mm aluminum extruded enclosure, sturdy swivel bracket, both direct and LMT connectivity, perforated metal, transducers: 4x2 woofer, 1x1 dome tweeter, input: euro block, sensitivity: 98dB, Nominal impedance: 8 ohm, crossover freq. 6kHz, freq. range: 160Hz~20kHz, Power Taps 100V: 5, 10, 20W, weight: 2.5kg etc as required. 41 (SH:-II Networking system) 42 Supplying, installation, testing and commissioning of Enterprise Grade Core Switch have 24 x 1G/10G/25G Fiber based ports and 4 x 40/100G QSFP+ ports, minimum 1.8 Tbps of switching fabric and minimum 900 Mpps of forwarding rate. minimum 8 GB RAM and minimum 8 GB Flash , Shall have minimum 50K MAC Addresses and 1K VLANs.must have hot swappable 1:1 redundant internal power supply and redundant fan. Must support BGP, VRF, VXLAN, OSPF Routed Access, Policy-Based Routing (PBR), PIM SM, and Virtual Router Redundancy Protocol (VRRP) from Day 1 with 5 Year Warranty 43 Supply, Installation, Testing & Commissioning of SFP+ 100G optical modules for fibre uplinks. Compatible for stacking of Core switches, includes 5 years warranty etc. complete asper attached specifications and as per direction of Engineer in Charge as per site requirement. 44 Supplying, installation, testing and commissioning of 24 Port PoE+ Access Switch: 16 x 10/100/1000 Base-T POE+ ports, 8 x multigig copper ports (2.5G/5G/10G) for Wi-Fi-6 APs and 4 x SFP+ uplinks ports and Dedicated/virtual Stacking Port and required cable for Stacking should be considered from Day1, 24 ports should support PoE (802.3af) and PoE+ (802.3at) with a PoE power budget of 370 Watts ,shall have minimum 270 Gbps or more of switching fabric and 210 Mpps (64 byte packet) of forwarding rate ,minimum 2 GB RAM and 4 GB Flash, minimum 16K MAC Addresses and 500 VLANs, should support internal hot-swappable Redundant Power supplies with 5 Year Warranty. 45 Supplying, installation, testing and commissioning of Access Switch NON POE 24 nos. 10/100/1000 Base-T ports. and 4 nos. SFP+ uplinks portsand Dedicated/virtual Stacking Port and required cable for Stacking should be considered from Day1,shall have minimum 128 Gbps or more of switching fabric and 95 Mpps (64 byte packet) of forwarding rate ,minimum 2 GB RAM and 2 GB Flash, minimum 16K MAC Addresses and 500 VLANs, should support internal hot-swappable Redundant Power supplies with 5 Year Warranty. 46 Supplying, installation, testing and commissioning ofWi-Fi 6 Indoor Access Point, MIMO - 4x4:4SS, Min. 2.50 Gbps Aggregate throughput, should support WIDS/WIPS inbuilt, should support BLE/IoT Radio. Interfaces - 1 x 100/1000/2500 Mbps with 05 Yrs of required Licenses and support. 47 Supply, Installation, Testing & Commissioning of SFP+ 10G optical modules for fibre uplinks. Compatible with access/core switches, includes 05 years warranty etc. complete asper attached specifications and as per direction of Engineer in Charge as per site requirement. 48 SITC of SDWAN Router supporting minimum 5 Gbps of IPv4 Forwarding throughput and minimum 2Gbps of IPSec throughput, minimum of 8 GB or more Memory and 16 GB or more flash storage, Multi-core x86 processor or better processor and minimum – 2 x 1G/10G SFP+ Wan Ports, 04 x 1G copper ports & should be updgradable if required, USB and RJ45 console Portsincludes 05 years warranty & Licenses etc as per site requirement. 49 Supply, Installation, Testing & Commissioning of UTP Cat 6a S/FTP Cable LSZH etc. in existing casing/ conduit/ wall/ trench etc complete asper attached specifications and as per direction of Engineer in Charge as per site requirement. 50 Supply, Installation, Testing & Commissioning of of19 1U straight Un-loaded Patch Panel, 24-portetc. complete as reqd. 51 Supply, Installation, Testing & Commissioning of Shielded Information outletsCategory 6a, EIA/TIA 568-C.2 etc. complete as reqd. 52 Supply, Installation, Testing & CommissioningofSquare Dual Face plate, 86mmx86mm 3x3complete 3 etc. complete as reqd. 53 Supply, Installation, Testing & Commissioning ofmounting patch card Cat 6a S/FTP, 1 meter long, etc. complete as reqd. 54 Supply, Installation, Testing & Commissioning ofmounting patch card Cat 6a S/FTP, 2 meter long,etc. complete as reqd. 55 Supply, Installation, Testing & Commissioning of 6-Core armoured LSZH indoor Multi ModeFiber cable OM4 etc as required. 56 Supply, Installation, Testing & Commissioningof 12 portFibre MMF OM4 Panel RackMountable with Loaded LC adapter plate, pigtails complete etc. complete as reqd. 57 Supply, Installation, Testing & Commissioning of 24 portFibre MMF OM4 Panel RackMountable with Loaded LC adapter plate, pigtails etc. complete as reqd. 58 Supply, Installation, Testing & Commissioning of LC-LC Style MMF OM4Fiber Patch Cord 2 Mtr etc. complete as reqd. 59 Supply, Installation, Testing & Commissioning of 3x3 metalic surface box ISI etc. complete as reqd. 60 Supply, Installation, Testing & Commissioning of Network Rack 9 U wall mount : 600W*600H with Accessories etc. complete as reqd. 61 Supply, Installation, Testing & Commissioning of Network Rack 12 U wall mount : 600W*600H with Accessories etc. complete as reqd. 62 Supply, Installation, Testing & Commissioning of Network Rack 27 U with below included: Network Rack 800W x800D, Top cover with 4 x cutout, 2 x cutout for cable entry. Bottom cover with 4 x cutout for cable entry. All cutouts blanked with Plastic caps. 2 pairs etc. complete as reqd. 63 Supply, Installation, Testing & Commissioning of Network Rack 42 U with below included: Network Rack 800W x 2000H x 800D, Top cover with 4 x cutout, 2 x cutout for cable entry. Bottom cover with 4 x cutout for cable entry. All cutouts blanked with Plastic caps. 2 pairs, 42 U 19 Profile Typeangle, Front Rack Type 1-800W X 2000(42U)H X 1000Detc. complete as reqd. 64 Supply, Installation, Testing & Commissioningof1U Cable Manager Horizontal Single sided etc. complete as reqd. 65 Supply, Installation, Testing & Commissioning of 3 KVA UPS 0.90 input power factorfeatures. THD(i) shall be less than 3% in the entire loading range. Input power factor shall be more than 0.95. from 25% to 100% load. UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Single Phase Input and Single Phase Output. ( Input - 220V - 250V, Single Phase, 2 wire. / Output - 200Volt, Single Phase, 2 Wire.)Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be internal type and suitable for 30 minute backup on 100% load etc. complete as reqd. 66 SITC of 10 KVA UPS 0.90 input power factorfeatures. THD(i) shall be less than 3% in the entire loading range. Input power factor shall be more than 0.95. from 25% to 100% load. UPS shall carry design output at 40 deg. Shall have soft start and hold of for incoming supply. Invertor capability to supply 150% load for 5 sec. Single Phase Input and Single Phase Output. ( Input - 220V - 250V, Single Phase, 2 wire. / Output - 200Volt, Single Phase, 2 Wire.)Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells. Battery shall be internal type and suitable for 30 minute backup on 100% load etc. complete as reqd. 67 Supply, Installation, Testing & Commissioning ofWater Leakage Detection System etc. complete as reqd. 68 Supply, Installation, Testing & Commissioning ofRodent control system etc. complete as reqd. 69 Supply, Installation, Testing & Commissioning ofSteel Cement Laminated Raised Floor, Size (mm): 600x600 35mm etc. complete as reqd. 70 Supply, Installation, Testing & Commissioning of Door access control system etc. complete as reqd. 71 Supplying and Fixing following sizes DLP PVC adaptable trunking system for laying of wires for various services complete with accessories such as angle and end cap, Junction, Jointetc. complete as required. 72 32 x 12.5 73 32 x 16 74 32 X 20 mm 75 80 X 50 mm 76 105 X 50 mm 77 150 X 50 mm 78 195 X 50 mm 79 Supplying & Laying of one number XLPE insulated stranded copper armoured power cable of 1.1 KV grade of following size in existing casing/ conduit/ tray/ wall/ Race ways / ductetc as complete asper attached specifications and as per direction of Engineer in Charge as per site requirement.a) 3 core 4 sq.mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
TenderDetail
Loading tenders