View Bid Results For Rou Maintenance Tenders

We found 72 Bid Results related to rou maintenance tenders. You can find Contractor details who won rou maintenance tenders along with contract details in Bid awards announcements section.

Filters
Stage
70
2
Tender Publishing Platform
44
28
State / UT
18
10
10
9
9
7
6
4
3
3
3
1
1
1
1
1
1
1
1
Contract Value
5
9
33
25
Publish Date
0
1
0
0
0
Sector
7
45
14
8
2
1
1
1
Ownership
4
31
21
19
1
Within keyword
Active filters:
Showing 1–2 of 72 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 48,000
Statutory Bodies & Commissions/Committees No of Bidders 3
Jammu and Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : 57.23 Lakh
Government Departments No of Bidders 2
Contract Date: Jan 13, 2026 Contract Value : 25.11 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Madhya Pradesh View Result →
13.
Railways #8268019 AOC
Supply Of Amc Of Hand-Held Terminals(Hht).Amc Of Hand-Held Terminals(Hht).,Amc Of Hand-Held Terminal (Hht) Quarterly Cost Per Device For Complete Maintenance. ( No Of Device 300 Total Duration: 2 Years, Total Quantity Of Quarterly Billing: 300*2 = 600 Nos.) Note: Tenderers Shall Quote Quarterly Cost Per Device. [ Warranty Period: 0 Years, Amc Period: 2 Years, Rate Of Discou Nting: 0 % ] ] At (Location) Sr.Dcm/Ckp, Ser Jharkhand 600.00 Numbers 2 570112180194 Amc (Y) Non Stock --- Yes Consignee Inr Screen/Display Replacement On A Need Basis For 20% Of The 300 Hht Devices. [ Warranty Pe Riod: 0 Years, Amc Period: 2 Years, Rate Of Discounting: 0 % ] ] At (Location) Sr.Dcm/Ckp, Ser Jharkhand 60.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 1 Days Of Issue Of Contract, Completion Within 730 Days : Within 730 Days Thereafter Thereafter. Payment Terms S.No Description Payment Terms 1 100% Payment After Acceptance Of Service By Consignee Through Consignee Receipt Note (Crn). Part Supply Of Service & Part Payment Is Allowed. Statutory Variation Clause Page 1 Of 6 Run Date/Time: 10/10/2025 18:31:57Ckp Div/South Eastern Rly Tender Document Tender No If255954 Closing Date/Time 13/10/2025 12:00 S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 General Conditions Of Contract: The Contract Shall Be Governed By Latest Version (Along With All Correction Slips) Of General Conditions Of Contract, And All Other Terms And Conditions Incorporated In The Tender Documents. 2 Irs Terms And Condition With Latest Amendment/Correction Slip And Ser Instruction To Tenderers & General Conditions Of Tender Are Applicable. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 This Is A Pac Tender On M/S. Datamini Normal Applicable To Yes Yes Allowed Technologies [India] Limited. Only All Bidders (Mandatory) Oem Or Their Authorized Dealers Are Eligible For Order. 2 Authorized Dealers/Agents Must Submit Normal Applicable To Yes Yes Allowed Tender Speciï¬C Authorization From Oem, All Bidders (Mandatory) Failing Which Their OffEr Shall Be Summarily Rejected. Purchase Order Is Not Considered As Performance. No Back Reference Shall Be Made In This Regard And Railway Decision Will Be Final. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Submitted Authenticated Copy Normal Applicable To No No Not Allowed Of The Document Authorizing The Signatory All Bidders To Submit OffEr And Commit On Behalf Of Tenderers. Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 For-Destination. Normal Applicable To Yes No Not Allowed All Bidders 2 Please Enter The Percentage Of Local Normal Applicable To Yes Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The General Conditions Of Tenders For Supply Contract. Page 2 Of 6 Run Date/Time: 10/10/2025 18:31:57Ckp Div/South Eastern Rly Tender Document Tender No If255954 Closing Date/Time 13/10/2025 12:00 3 Preference To Make In India Policy: A) Normal Applicable To Yes Yes Allowed Procurement Of The Item Is Restricted To All Bidders (Mandatory) Class I/Ii Local Suppliers Only And The Vendors Who Do Not Qualify To Be Class I/Ii Local Suppliers Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class I/Ii Local Supplier For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. Requirement Of A Vendor To Be Class-I/Ii Local Supplier, Shall Be A Mandatory Condition In Addition To Other Qualifying /Eligibility Criteria/Conditions. ( Refer Para No 29.0 Of General Conditions Of Tender For Supply Contract Attached). 4 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Mse Sources, For Availing Beneï¬Ts Under Normal Applicable To No No Not Allowed Msme Act, Should Upload Valid Documents All Bidders Maintained Under Msme Act Such As Nsic Certiï¬Cate Etc. Duly Marking The Tendered Item In The Certiï¬Cate . Otherwise, Claim For Beneï¬Ts Under Msme Act May Not Be Entertained. 2 Mse Sources Owned By Sc/St, Should Normal Applicable To No No Not Allowed Upload Necessary Documents To Get The All Bidders Beneï¬Ts Being Owned By Sc/St. Otherwise, Claim For Beneï¬Ts Under Msme Act May Not Be Entertained. 3 If You Are Not A Mse Or A Consortia Of Normal Applicable To No No Not Allowed Mses Formed By Nsic, Please Indicate All Bidders Percentage Of Sub Contracts In Execution Of This Tender That Will Be From Micro And Small Enterprise(In Percent Of Order Value ) With Further Breakup Of Mse Owned By Sc/St. (Information Will Be Provided In % Terms With 6 ϬElds; Micro Owned By Sc, Micro Owned By St, Micro Owned By Others, Small Industry Owned By Sc, Small Industry Owned By St, Small Industry Owned By Others). 4 Emd Will Be Applicable As Per Para 5 Of Normal Applicable To No No Not Allowed Ser Inst. To Tender And G.C. Of Tender. All Bidders (Document Attached). 5 Sd Will Be Applicable As Per Para 6 Of Ser Normal Applicable To No No Not Allowed Inst. To Tender And G.C. Of Tender. All Bidders (Document Attached). Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Inspection By Consignee. Normal Applicable To No No Not Allowed All Bidders 2 Firm Should Quote Gstin. Normal Applicable To Yes Yes Allowed All Bidders (Mandatory) Page 3 Of 6 Run Date/Time: 10/10/2025 18:31:57Ckp Div/South Eastern Rly Tender Document Tender No If255954 Closing Date/Time 13/10/2025 12:00 3 Successful Tenderer/Bidder Should Upload Normal Applicable To Yes Yes Allowed Declaration Regarding Aggregate Turn Over All Bidders (Mandatory) As Per Enclosed Of Railway Boards Letter No.2016/A-Ii/01/06/Cris Dated 08.10.2020 (Pdf Doc. Enclosed/Attached For Ready Reference) In Ireps. Further They Will Also Ensure While Submitting The Bill For Releasing Payment To Bill Passing Oï¬Ƒcer/Consignee That They Will Send One Copy Of The Said Declaration In Original Duly Signed And Stamped To Bill Passing Officer/Consignee. 3.1 Special Condition:- : 1 . 1 All Batteries Normal Applicable To Yes Yes Allowed Covered Under Amc Should Be Replaced All Bidders (Optional) Within The Amc Period. 1.2 The ϬRm Will Attend To The Complaint Within Three Days Of The Problem Being Reported. 1 . 3 Firm Will Bear Cost Of All Spares Required During Repair And Maintenance Of Devices. 1 . 4 The Bidder Should Not Refuse To Replace The Battery If The Battery Backup Falls Below 2 Hours During The Amc Period. 1 . 5 Location List Of Hht Devices 1. Cti (I/C)/Tata- 91 Nos. 2. Cti (I/C)/Ckp- 75 Nos. 3. Cti (I/C)/ Rou- 96 Nos. 4.Cti (I/C)/Jsg- 38 Nos. 1.6 Billing Cycle: Quarterly. Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 All The Bidders/Tenderers Should Insure Normal Applicable To No No Not Allowed That They Are Gst Complaint And Their All Bidders Quoted Tax Structure/Rates As Per Gst Law. In Case The Successful Tenderer Is Not Liable To Be Register Under Cgst/Igst/Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. It Is The Responsibility Of The Bidder To Quote Correct Hsn Number And Corresponding Gst Rate. The OffEr Shall Be Evaluated Based On Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining Inter Se Ranking. Purchaser Will Not Be Responsible For Any Miss Classiï¬Cation Of Hsn Number Or Incorrect Gst Quoted By Bidder. Whenever Successful Bidder Invoices, The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In Po, Payment Shall Be Made At Gst Rate Which Is Lower Of Gst Rate Incorporated In Po Or Billed. Vendor Is Informed That They Would Be Required To Adjust Their Basic Price To The Extent Required By Higher Tax Billed As Per Invoice To Match The All Inclusive Price As Mentioned In Po. Post Tender Opening, Any Amendment In Gst Rate By Govt. For Hsn Code Mentioned In Po Will Be Dealt Under Svc. Page 4 Of 6 Run Date/Time: 10/10/2025 18:31:57Ckp Div/South Eastern Rly Tender Document Tender No If255954 Closing Date/Time 13/10/2025 12:00 2 The Purchaser Reserved The Right To Cancel Normal Applicable To No No Not Allowed The Po Consequent To Breach Of Contract All Bidders Under Risk And Cost Or By Levying 5% Of Po Value For Unsupplied Portion Of Contract As General Damage, Or Forfeiture Of Security Deposit, As Deemed ϬT By The Purchaser. The General Damages Can Be Recovered From Any Supply Bills Of The ϬRm In Indian Railways, If The ϬRm Fails To Deposit Within Stipulated Time. 3 Reciprocity Clause: Bidders May Please Normal Applicable To No No Not Allowed Note That- Entities Of Countries Which Have All Bidders Been Identiï¬Ed By The Nodal Ministry/Department As Not Allowing Indian Companies To Participate In Their Government Procurement For Any Item Related To That Ministry/ Department Shall Not Be Allowed To Participate In Government From In India For All Items Related To That Nodal Ministry/Department, Except For The List Of Items Published By The Ministry/Department Permitting Their Participation. The Term Entity Of A Country Shall Have The Same Meaning As In The Fdi Policy Of Dpiit As Amended From Time To Time. 6. Bidders Shall Confirm And Certify On The Behalf Of The Tenderer Including Its Constituents As Under: S.No. Description 1 I/We The Tenderer (S) Am/Are Signing This Document After Carefully Reading The Contents. 2 I/We The Tenderer(S) Also Accept All The Conditions Of The Tender And Have Signed All The Pages In Confirmation Thereof. I/We Hereby Declare That I/We Have Downloaded The Tender Documents From Indian Railway Website Www.Ireps.Gov.In . I/We Have Verified The Content Of The Document From The Website And There Is No Addition, No Deletion Or No Alteration To The 3 Content Of The Tender Document. In Case Of Any Discrepancy Noticed At Any Stage I.E. Evaluation Of Tenders, Execution Of Contract Or Payment, The Master Copy Available With The Railway Administration Shall Be Final And Binding Upon Me/Us. I/We Declare And Certify That I/We Have Not Made Any Misleading Or False Representation In The Forms, Statements And 4 Attachments In Proof Of The Qualification Requirements. I/We Also Understand That My/Our Offer Will Be Evaluated Based On The Documents/Credentials Submitted Along With The Offer 5 And Same Shall Be Binding Upon Me/Us. I/We Declare That The Information And Documents Submitted Along With The Tender By Me/Us Are Correct And I/We Are Fully 6 Responsible For The Correctness Of The Information And Documents, Submitted By Us. I/We Certify That I/We The Tenderer(S) Is/Are Not Blacklisted Or Debarred By Railways Or Any Other Ministry / Department Of 7 Govt. Of India From Participation In Tender On The Date Of Submission Of Bids, Either In Individual Capacity Or As A Huf/ Member Of The Partnership Firm/Llp/Jv/Society/Trust. I/We Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be Forged/False At Any Time During Process For Evaluation Of Tenders, It Shall Lead To Forfeiture Of The Emd And May Also Lead To Any Other Action Provided In The 8 Contract Including Banning Of Business For A Period Of Upto Two Year. Further, I/We And All My/Our Constituents Understand That My/Our Offer Shall Be Summarily Rejected. I/We Also Understand That If The Contents Of The Certificate Submitted By Us Are Found To Be False/Forged At Any Time After The 9 Award Of The Contract, It Will Lead To Termination Of The Contract, Along With Forfeiture Of Security Deposit And May Also Lead To Any Other Action Provided In The Contract Including Banning Of Business For A Period Of Upto Two Year. I/We Have Read The Clause Regarding Restriction On Procurement From A Bidder Of A Country Which Shares A Land Border With India And Certify That I Am/We Are Not From Such A Country Or, If From Such A Country, Have Been Registered With The 10 Competent Authority. I/We Hereby Certify That I/We Fulfil All The Requirements In This Regard And Am/Are Eligible To Be Considered (Evidence Of Valid Registration By The Competent Authority Is Enclosed) 7. Documents Attached With Tender S.No. Document Name Document Description 1 5399269.Pdf Irs Condition Of Contract. 2 5338626.Pdf Rly. Boards Letter Dtd. 08.10.20 3 5398977.Pdf Ser Inst.To Tenderer &Gc. Of Tender W.E.F.16.05.25 The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid Page 5 Of 6 Run Date/Time: 10/10/2025 18:31:57Ckp Div/South Eastern Rly Tender Document Tender No If255954 Closing Date/Time 13/10/2025 12:00 This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Sr.Dmm-Ckp ( Ashwini Kumar ) , Screen/Display Replacement On A Need Basis For 20% Of The 300 Hht Devices. [ Warranty Pe Riod: 0 Years, Amc Period: 2 Years, Rate Of Discounting: 0 % ] ] At (Location) Sr.Dcm/Ckp, Ser Jharkhand 60.00 Numbers
Contract Date: Nov 14, 2025 Contract Value : 15.71 Lakh
Government Departments No of Bidders 1
Contract Date: Mar 29, 2025 Contract Value : 33.19 Lakh
Boards / Undertakings / PSU No of Bidders 5
Contract Date: Mar 28, 2025 Contract Value : 2.02 Crore
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Feb 17, 2025 Contract Value : 1.12 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Feb 17, 2025 Contract Value : 64.56 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 2.66 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 16.52 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 4.03 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
42.
Petroleum and Natural Gas #4904367 AOC
Bids Are Invited For Part - B -Item-1 - Supply & Installation Of Manual Test Stations ( Mts ) Complete With Lower Bend And With Pcc Foundation Including, Terminal Plate, Diagram Plate, Cable Identification Ferrules, & Proper Cable Termination With Lugs, Numbering Of Ts Etc. As Per Drawing & Specification ( With Ip55 ) Complete In All Respect And Per Instruction Of Eic , Part - B -Item-2 - Supply & Installation Of Manual Test Stations ( Mts ) Without Lower Bend & Without Pcc Foundation Including Terminal Plate, Diagram Plate, Cable Identification Ferrules & Proper Cable Termination With Lugs, Numbering Of Ts Etc. As Per Drawing & Specification ( With Ip55 ) Complete In All Respect And Per Instruction Of Eic. , Part - B -Item-3 - Shifting Of Mts Along With Foundation And Cable To Suitable Nearby Location As Per Instruction Of Eic. ( Cable Extra ) , Part - B -Item-4 - Repairing Of Mts Foundation With Supply And Replacement Of Foundation Bolts & Nuts Including Labour , Tools, Tackles Consumeables Like Cement, Sand Aggregates, Etc Complete In All Respect As Per Scope Of Work, Specifications And Direction Of Eic , Part - B -Item-5 - Repairing Of Mts Including Supply And Replacement Of Damaged Door, Door Locks, Terminal Plate, Diagram Plate, Neoprene Gasket, Brass Links Cable Identification Ferrules Etc In Mts With Proper Cable Termination, Cable Jointing, Lugs, With Numbering Of Ts Complete In All Respect Including Labour, Tools, Tackles, Consumeables Like Ms / Brass Bolts, Nuts, Washers, Insulation Tape Etc.As Per Scope Of Work Specifications And The Direction Of Eic , Part - B -Item-6 - Supply & Replacement Of Damaged / Missing Locks In Mts Including Labor, Consumables And Tools & Tackles As Per Drawings, Specifications & Instructions Of Eic. , Part - B -Item-7 - Supply & Installation Of Damaged / Missing Terminal Plates ( All Types ) With M10 Brass Studs, Washers, Links, Lugs & Nuts, Including Labor, Tools & Tackles And Consumables As Per Instruction Of Eic , Part - B -Item-8 - Supply And Fixing Of Diagram Plate In The Existing Manual Test Station ( All Types ) Complete In All Respect Including Labour, Tools, Tackles, Consumeables Etc. As Per Scope Of Work Specifications And The Direction Of Eic , Part - B -Item-9 - Identification Of Cables In Test Station: The Cables Inside The Test Station Shall Be Identified As Per Diagram Plate / Sticker By Proper Dressing, Identification Ferrules, Carrying Out Necessary Termination With Copper Lugs Of Required Size And As Per The Direction Of Eic. The Cable Dressing Shall Be Strictly As Per The Diagram Plate , Part - B -Item-10 - Supply And Fixing Of Neo-Prene Gasket In Mts Box Sizes ( All Types ) As Per Scope Of Work And Directions Of Eic. , Part - B -Item-11 - Repairing Of Aljb Including Supply Of New Locks & Latch For The Outer Enclosure, Shunt, Variable Resistance, Brass Links, Aljb Doors Including Welding Mechanical, Straightening Of Pipe, Fittings, Hinges, Labour, Tools Tackles, Consumables Like Lugs, Ms / Brass Nuts, Bolts, Washers, Insulation Tape Etc Complete In All Respect As Per Approved Drawings, Specification And As Per Direction Of Eic. , Part - B -Item-12 - Supply Of Xlpe Armoured Copper Cableof 4 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - B -Item-13 - Supply Of Xlpe Armoured Copper Cableof 6 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - B -Item-14 - Supply Of Xlpe Armoured Copper Cableof 10 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - B -Item-15 - Supply Of Xlpe Armoured Copper Cableof 25 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - B -Item-16 - Supply Of Xlpe Armoured Copper Cableof35 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - B -Item-17 - Cable Laying Of 4 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - B -Item-18 - Cable Laying Of 6 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - B -Item-19 - Cable Laying Of 10 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - B -Item-20 - Cable Laying Of 25 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - B -Item-21 - Cable Laying Of 35 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - B -Item-22 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 4 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - B -Item-23 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 6 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - B -Item-24 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 10 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - B -Item-25 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 25 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - B -Item-26 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 35 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - B -Item-27 - Making Of Pipe To Cable Connection As Per Approved Procedure, Of All Types Of Cable Including Excavation And Backfilling, Surface Preparation, Pipe To Cable Connection By Means Of Pin Brazing Its Encapsulation, Holiday Testing Of The Exposed Section, Labour, Tools, Tackles Etc As Per Scope Of Work, Specifications And Direction Of Eic . ( Pin Brazing Kit And Holiday Detector Will Be In The Scope Of The Contractor ) . , Part - B -Item-28 - Painting Of Manual Test Station Including Removing Of Old Paint, Rust Etc Using Emery Paper, Surface Preparation To Get The Smooth Level Surface, Supply And Application Of 01 Coat Of Ready Mix Red Oxide Primer Of Approved Make, 02 Coats Of Ready Mixed First Quality Paint Of Approved Brand. ( Final Dry Paint Thickness Not Less Than 100 Micron ) , Numbering Of Test Station As Per Scope Of Work, Specification And As Per Direction Of Eic. , Part - B -Item-29 - Painting Of Anode Lead Junction Box Including Removing Of Old Paint, Rust Etc Using Emery Paper, Surface Preparation To Get The Smooth Level Surface, Supply And Application Of 01 Coat Of Ready Mix Red Oxide Primer Of Approved Make, 02 Coats Of Ready Mixed First Quality Paint Of Approved Brand. ( Final Dry Paint Thickness Not Less Than 100 Micron ) , Numbering Of Test Station As Per Scope Of Work, Specification And As Per Direction Of Eic. , Part - B -Item-30 - Painting Of Tr Unit Including Removing Of Old Paint, Rust Etc Using Emery Paper, Surface Preparation To Get The Smooth Level Surface, Supply And Application Of 01 Coat Of Ready Mix Red Oxide Primer Of Approved Make, 02 Coats Of Ready Mixed First Quality Paint Of Approved Brand. ( Final Dry Paint Thickness Not Less Than 100 Micron ) , Numbering Of Test Station As Per Scope Of Work, Specification And As Per Direction Of Eic. , Part - B -Item-31 - Supply & Replacement Of Imported Copper-Copper Sulphate Permanent Refrenece Cells ( Make Mc Miller / Tinker & Rasor Company / Caproco ) Necessary Backfill Material Including Excavation / Backfilling Cable Laying, Cable Identification Ferrules, Labour, Tools, Tackles, Consumables Like Sand, Brick, Lug, Brass Washers, Insulation Tape Etc, Complete In All Respects As Per Scope Of Work Drawings, Specification And Direction Of Eic. , Part - B -Item-32 - Supply And Installation Of Pre-Packed Magnesium Anodes With Cable Having Weight 17 Pounds Including Excavation, Backfilling, Cable Laying Up To Test Station And Cable Termination In Test Station, Cable Identification Ferrules, With Consumables Labour Etc. As Per Approved Drawing, Specification And Direction Of Eic , Part - B -Item-33 - Supply , Replacement & Installation Of Prepacked Single Zinc Anode ( 11Kg ) Of Reputed Make Including Excavation, Backfilling, Anode To Tail Cable Connection, Cable Identification, Coke Breeze Backfill Complete With Labor, Tools & Tackles As Per Drawings, Specifications & Instructions Of Eic , Part - B -Item-34 - Supply And Installation Of Pre Packed Pair Of Zinc Grounding Cell 22Kg Including All Tools, Tackles, Consumables, Labour, Chemical Back Fill, Excavation, Backfilling, Cable To Insert Joint, Laying Of Tail Cable, Cable Termination At Ts Complete And In All Respect As Per Drawing, Specification And As Per Direction Of Eic , Part - B -Item-35 - Supply Of Earthing Strip 25 Mm X 4 Mm Size: Conducton Material: Gi Conforming To Is Code 2629, Zinc Deposition: Not Less Than 610 Grams / Square Meter, Length Of Strip: Minimum 7 Mtr And Maximum 10Mtr, Thickness Of Zinc Coating: Not Less Than 86 Micron And Smooth, Continuous, Uniform & Free From Acid Spot, Galvanizing Process: Hot Dip Galvanized And As Per Scope Of Work& Specification In All Respect And As Per Instruction Of Eic. , Part - B -Item-36 - Supply Of Earthing Strip 50 Mm X 6 Mm Size: Conducton Material: Gi Conforming To Is Code 2629, Zinc Deposition: Not Less Than 610 Grams / Square Meter, Length Of Strip: Minimum 7 Mtr And Maximum 10Mtr, Thickness Of Zinc Coating: Not Less Than 86 Micron And Smooth, Continuous, Uniform & Free From Acid Spot, Galvanizing Process: Hot Dip Galvanized And As Per Scope Of Work& Specification In All Respect And As Per Instruction Of Eic. , Part - B -Item-37 - Laying Of Hot Dip Galvanized Of 25 Mm X 4 Mm Iron Earth Strip In Buried Trench At A Depth Of Minimum Upto 150 Mm From Fgl. Work Includes Civil Work Like Excavation, Breaking Of Pcc / Rcc & Back Filling After Laying Of Earth Strip, Welding Of Joints & Applying 2 Layers Of Bitumen Etc. As Per Scope Of Work & Specfication In All Respect And As Per Instruction Of Eic , Part - B -Item-38 - Laying Of Hot Dip Galvanized Of 50 Mm X 6 Mm Iron Earth Strip In Buried Trench At A Depth Of Minimum Upto 150 Mm From Fgl. Work Includes Civil Work Like Excavation, Breaking Of Pcc / Rcc & Back Filling After Laying Of Earth Strip, Welding Of Joints & Applying 2 Layers Of Bitumen Etc. As Per Scope Of Work & Specfication In All Respect And As Per Instruction Of Eic , Part - B -Item-39 - Construction Of Normal Earth Pit Scope Of Woks Includes Erection & Commissioning Ofearth Pits At Sv / Rr / Ip Stations Of Pipeline Wherever It Is Required Which Includes Supply Of All Required Material As Per Specification Like- 75 Mm Dia, 4.5 Mm Thickeness Earthelectrode, Gi Strip, Copper Cable, Bolt, Nuts / Check Nuts, Funnel, Back Filling Compound For Filling Around The Electrode, And Excavation Of Pit As Per Drawing Up To A Depth Of 3.5 Meter Minimum, Making Of Pit With Brick, Sand, Cement & Smooth Plastering, Fixing Of Ms Cover 6Mm Thickness, Termination Of Earth Wire / Cable / Strip & Connect Earth Pit With Grid And Also Ensure Continuity With Grid , Part - B -Item-40 - Construction Of Chemical Earth Pit: Scope Of Woks Includes Erection & Commissioning Of Chemical Earth Pits At Sv / Rr / Ip Stations Of Pipeline Wherever It Is Required Which Includes Supply Of All Required Material As Per Specification Like- Electrode, Gi Strip, Copper Cable, Bolt, Nuts / Check Nuts, Funnel, Back Filling Compound For Filling Around The Electrode, And Excavation Of Pit As Per Drawing Up To A Depth Of 3.5 Meter Minimum, Making Of Pit With Brick, Sand, Cement & Smooth Plastering, Fixing Of Ms Cover 6Mm Thickness, Termination Of Earth Wire / Cable / Strip & Connect Earth Pit With Grid And Also Ensure Continuity With Grid In All Respect As Per The Scope Of Work And Drawings And As Per Instruction Of Eic. , Part - B -Item-41 - Supply Ofearth Pit Chamber Ms Cover Of 6 Mm Thickness , Part - B -Item-42 - Preventive Maintenence Of Polarisation Cells / Kirk Cells Supply Of Koh Electrolyte, Complete In All Respect To Make The Cell In Working Condition And As Per Specifications And Instructions Of Eic , Part - B -Item-43 - Preventive Maintenance Of Anode Ground Bed -The Scope Of Work Includes Necessary Excavation For Carrying Out Ground Bed Curing With 500 Kg Of Common Salt And Water Of 18 Kl. The Work Includes Necessary Backfilling And Restoration To The Original Condition As Per The Direction Of Eic. The Contractor Shall Measure The Grounded Resistance After The Treatment Of Ground Bed. The Resistance Of Grounded After The Maintenance Shall Be Less Than 01 Ohm. Clearance If Any Required From Land Owner For Entering / Working In His Permisses Will Be In The Contractors Scope , Part - B -Item-44 - Supply And Installation Of Cable Markers ( Ci / Cs / Ms ) For Underground Cables And Equipment As Per The Scope Of Work And Specfication In All Respect And As Per The Instruction Of Eic. , Part - B -Item-45 - Carrying Out On-Off Close Interval Potential Survey ( Cipl ) With Lateral Gradient At One Meter Interval Using Data Loggers And Standard Cu / Cuso4 Reference Electrode Including Detailed Reports And As Per The Scope Of The Work And Specification In All Respect And As Per Instrution Of Eic. , Part - B -Item-46 - Stray Current Interference Survey At Railway Crossing Or Runnig Parallel To Gail Pipelines, Including 24 Hours Data Logging, Data Collection From Railways, Study The Effectiveness Of Existing Diode Bonding And Recommend Mitigation Measures / Modification Required At Existing Doide Jb, At All The Railway Crossings Or Running Parallel As Defined In Scope Of Work With Specification, Design And Detail Engineering In All Respect And As Per Instruction Of Eic. , Part - B -Item-47 - Stray Current Interference Survey At Foreign P / L Crossing Or Runnig Parallel With Gail Pipeline, Including 24 Hours Data Logging, Data Collection From Foreign Pipeline Operator, And Recommend Mitigation Measures At Foreign Pipeline Crossing Or Running Parallel To Gail Pipeline As Defined In The Scope Of Work, With Design, Specification And Detail Enggineering In All Respect And As Per Instruction Of Eic. , Part - B -Item-48 - Stray Current Interference Survey At Ht Crossings Or Runnig Parallel To Gail Pipelines, Including 24 Hours Data Logging, Collection Of Data From Seb, Calculation Of Human Touch And Step Voltages, Measurent And Calculation Of Ac Corrossion Current And Recommendation For Mitigation / Effectiveness Of Existing Grounding With Modification If Required, At Ht Line Crossings / Parallel Sections As Defined In The Scope Of Work With Design, Specification And Detail Enggineering In All Respect And As Per Instruction Of Eic.. , Part - B -Item-49 - Adequacy Of Cp Station , Study The Adequacy Of Existing Cp Stations ( Cptr & Cppsm ) , Including Effectiveness And Efficiency Of Remote Anode Bed, Effective Span Of Polarised Protection On The Pipelines From The Drain Point, Mode Of Operation For The Purpose Of Adequacy And Better Operation Of The Cp System And As Defined In The Scope Of Work In All Respect And As Per Instruction Of Eic.. , Part - B -Item-50 - Carryingout Current Attenuation Test / Direct Current Voltage Gradient ( Dcvg ) Survey Using Standard Dcvg Equipment To Pin Point The Coating Defect / Holidays On Pipeline As Per The Specifications In All Respect And As Per Instruction Of Eic.. , Part - B -Item-51 - Excavation Of Pipeline In All Type Of Soils And Ordinary Rocks For A Width Of D+500 Mm On Each Side Of Pipe And Exposing The Pipeline From Top Upto 500 Mm Below The Bottom Of Pipeline Including The Stacking Of Excavated Earth, Stacked Earth To Be Levelled And Neatly Dressed As Per The Scope Of Work And Directions Of Eic , Part - B -Item-52 - Backfilling Excavated Earth ( Excluding Rock ) In Trenches In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, As Per The Scope Of Work And Directions Of Eic. , Part - B -Item-53 - Coating Repair- Removing The Old / Damaged Coating / Rust Greese, Moisture And All Foreign Material At Defect Location With Scrapper, Manual Surface Preparation Using Hand Wire Brush, Emery Paper, Scrappers Or A Combination Of All Processes, Repairng Of The Coating With Supply Of Raychem Sleeves / Cold Applied Tape / Perp / Patch Repair Kit, Holiday Testing After Repair, As Per The Scope Of Work And To The Entire Satisfaction Of Eic. Multiple Patch Repairing At One Location Within One Meter Span Shall Be Trated As Single Quantity Only. Coating Material Will Be Supplied By Gail. ( Compensation, If Required To Land Owners Shall Be In The Scope Of Contractor ) , Part - B -Item-54 - Supply & Installation Of Surge Diverters ( Dehn / Equivalent ) In Mts At Ht Power Line Crossings Including Cable Identification, Labor, Tools & Tackles, Brass Studs / Nuts And Sundry Consumables , Part - B -Item-55 - Supply & Installation Of Explsoin Proof Spark Gap Arrestors Of Dehn Exsg4 / Equivalent Make Across Insulating Joints At Sv / Ip / Rr / Terminals Including Required Cable ( 25Sqmm, Cu ) , Lugs, Nuts & Bolts, Labor, Tools & Tackles, And Sundry Consumables , Part - B -Item-56 - Supply Of Portable Cu-Cuso4 Half Cell For Measuring Of Psp ( Pipe To Soil Potential ) Of Pipeline , Part - B -Item-57 - Anode Lead Junction Box ( Size :-500 X 700 X 250 ) Supply, Installation, Testing And Commissioning Of Anode Lead Junction Box Including Required Backelite Plate Brass Nut Bolts, Port Type Resistor & Shunt Arrangement, Civil Works With Materials As Per Eic , Part - B -Item-58 - Reconditioning / Recharging / Maintenance Of Existing Earth Pit At Rr / Terminals With Raising The Height Of Civil Foundation, Repair Of Cement Plastering, Painting Of Top Cover Plates And Numbering Of Earthpits. Supply Of Common Salt 50 Kg And Water 100L For Bringing Down The Circuit Resistance Including Making Necessary Excavation, Mixing & Pouring Of Salt & Water, Replacement & Cleaning Of Connecting Nuts And Bolts, Etc Complete In All Respect And As Per Directions Of Eic , Part - B -Item-59 - Installation & Commissioning Of Gail Supplied Corrosion Censing Probe At Sv / Rr Stations Of Hvj Pipeline In All Kind Of Soil Including Excavation, Installation, Termination In Manual Test Stations And Backfilling / Restoration To The Original Ground Condition Under Dibiyapur Region As Per Scope Of Work And Direction Of Eic. , Part - B -Item-60 - Bell Hole Inspection: Excavation In All Type Of Soils And Ordinary Rocks For A Width Of D+500 Mm On Each Side Of Pipe And Exposing The Pipeline From Top Upto 500 Mm Below The Bottom Of Pipeline Including The Stacking Of Excavated Earth On Pipeline For Bell Hole Inspection For Checking The Health Of Pipeline Including Backfilling & Restoration To Original Condition In All Respect As Per Direction Of Eic. , Part - B -Item-61 - Supply Installation & Commissioning Of Sspc ( Solid State Polarisation Cell ) In New Installation / Existing System In Case Of Damaged As Per Ace / Vde Specifications For Protection Of Hv / Ehv Power Lines Crossings, Iccc ( Rustroll System ) , Dairyland Or Equivalent Make ( As Approved By Eic ) Suitable For Arresting Induce Ac Fault Currents, Lightning & Surge Protection, Dc Voltage ( > 3 Volts ) And Blocking The Protective Cathodic Protection Current On The Pipeline. Supply Of Sspc, ( As Per Specification Mentioned In This Tender Documents ) , Test Station Of Suitable Size, Required Length & Size Of Cable, Consumables With Testing & Data Logging Before And After Installation ( Report To Be Submitted ) Are In The Scope Of Contractor. Complete In All Respect And As Per Direction, Specification Of Eic , Part - B -Item-62 - Soil Resistivity Survey By Wenner Four Point Method , Part - B -Item-63 - Supply And Installation Of End Seals Of Both Side Of Casings For 8 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part - B -Item-64 - Supply And Installation Of End Seals Of Both Side Of Casings For 18 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part - B -Item-65 - Supply And Installation Of End Seals Of Both Side Of Casings For 24 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part - B -Item-66 - Rectification Of Short Casing , Part - B -Item-67 - Maintenance Of Lightning System ( Outdoor ) Maintenance Of Lighting System At Rr / Sv Station Under Dibiyapur Region. ( Height Of Pole Upto 12 M ) . All Consumable Materials, Ladder, Manpower, Vehicle Required For Maintenance Of Street Pole Light Will Under Scope Of Vendor. , Part - B -Item-68 - Supply & Installation Of Distribution Box :Supply & Installation Of Distribution Box With 63A / 100A Tpmccb, Bakelite Fuse, Bus Bar, Neutral Link In M.S. Sheet Enclosure Of Size Not Less Than 500X750x200mm With Enamel Painting And Cable Entry Holes With Lockable Door. All Mentioned Items Will Be In Scope Of Vendor. , Part - B -Item-69 - Supply, Installation & Commissioning Of Polarization Coupon Along With Magnetic Reed Switch As Per The Scope Of Work , Part - B -Item-70 - Supply Of Solar Charge Contr. 12V / 10A Dc At Sv Stations : Scope Of Work Shall Include Supply And Installation Of Solar Charge Controller For Pole Mounted Solar Light, 12V Dc, 10A ( As Per Installed System ) As Per Direction, Specification & Satisfaction Of Eic , Part - B -Item-71 - Supply Of Solar Charge Contr.Solar Plant: Scope Of Work Shall Include Supply And Installation Of Solar Charge Controller For Solar Plant, 96V Dc / 100A Or 120V Dc / 100A, 48V Dc / 180A ( As Per Installed System ) As Per Direction, Specification & Satisfaction Of Eic. , Part - B -Item-72 - Supply Of Dc / Dc Converter At Rr Station : Scope Of Work Should Include Supply And Installation Of Dc-Dc Converter At Rr / Ip Stations Under Dibiyapur. Input 30 V-70 V. Ouput 48 V , 21A. The Quanity Mentioned Against Each Maintenance Basemay Be Used In Other Region If Required. , Part - B -Item-73 - Permission From Statuary Authority: Scope Of Work Shall Include Granting Permission From Statuary Authority ( Railways / Highway / Forest / Any Government Related Authority ) For Any Kind Of Job In Their Rou Or In Forest Land As Per Requirement Of Gail. Transportation And Other Expenses Involved In The Job Shall Be In The Scope Of Contractor , Part - B -Item-74 - Preventive Maintenance Of Window / Spilt Preventive Maintenance Of Window / Spilit A / C Upto 3 Tons As Per Scope Of Work , Part - B -Item-75 - Preventive Maintenance Of Water Coolers Preventive Maintenance Of Water Coolers Up To 150 Ltrs As Per Scope Of Work , Part - B -Item-76 - Preventive Maintenance Of Refrigerator / D Preventive Maintenance Of Refrigerators / Deep Freezers Upto 350 Ltrs As Per Scope Of Work , Part - B -Item-77 - Sitc Of Starting Capacitor ( 80-100Mfd ) , Part - B -Item-78 - Sitc Of Running Capacitor ( 36 Mfd ) , Part - B -Item-79 - Sitc Of Starting Relay For A / C, Wc, Rg , Part - B -Item-80 - Sitc Of Thermostat , Part - B -Item-81 - Sitc Of Over Load Relay A / C, Wc, Rg , Part - B -Item-82 - Sitc Of Shaft For Blower Motor , Part - B -Item-83 - Sitc Of Bush For Blower Motor , Part - B -Item-84 - Sitc Of Float Valve For Water Cooler , Part - B -Item-85 - Sitc Of Fan Blade For Condenser , Part - B -Item-86 - Sitc Of Selector / Rotary Switch A / C , Part - B -Item-87 - Sitc Of Air Filter For Cooling Coil Of A Sitc Of Air Filter For Cooling Coil Of A / C , Part - B -Item-88 - Sitc Of Blower For A / C , Part - B -Item-89 - Sitc Of The Faulty Compressor Of Window / Split Sitc Of The Faulty Compressor Of Window / Split Ac Upto 3 Ton With New One In Buyback Scheme Of Old Burnet Compressor As Per Scope Of Work And Direction Of Eic , Part - B -Item-90 - Sitc Of The Faulty Compressor Of Refrige Sitc Of The Faulty Compressor Of Refrigerator / Water Cooler Upto 350 Ltr. With New One In Buyback Scheme Of Old Burnet Compressor As Per Scope Of Work And Direction Of Eic , Part - B -Item-91 - Sitc Of The Control Card For Single Ph Sitc Of The Control Card For Single Phase Window / Split Ac As Per Scope Of Work And Direction Of Eic , Part - B -Item-92 - Sitc Of Capillary / Copper Pipe Require Fo Sitc Of Capillary / Copper Pipe Require For Window / Split Ac , Water Cooler Refregerator Application As Per Scope Of Work And Direction Of Eic , Part - B -Item-93 - Supply And Charging Of Refregient Gas To Supply And Charging Of Refregient Gas To The Compressor Of Split / Window Ac / Refregerator / Water Cooler As Per Scope Of Work And Direction Of Eic Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 2.65 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
43.
Petroleum and Natural Gas #4904365 AOC
Bids Are Invited For Part-A-Item - 1 - Supply & Installation Of Manual Test Stations ( Mts ) Complete With Lower Bend And With Pcc Foundation Including, Terminal Plate, Diagram Plate, Cable Identification Ferrules, & Proper Cable Termination With Lugs, Numbering Of Ts Etc. As Per Drawing & Specification ( With Ip55 ) Complete In All Respect And Per Instruction Of Eic , Part-A-Item - 2 - Supply & Installation Of Manual Test Stations ( Mts ) Without Lower Bend & Without Pcc Foundation Including Terminal Plate, Diagram Plate, Cable Identification Ferrules & Proper Cable Termination With Lugs, Numbering Of Ts Etc. As Per Drawing & Specification ( With Ip55 ) Complete In All Respect And Per Instruction Of Eic. , Part-A-Item - 3 - Shifting Of Mts Along With Foundation And Cable To Suitable Nearby Location As Per Instruction Of Eic. ( Cable Extra ) , Part-A-Item - 4 - Repairing Of Mts Foundation With Supply And Replacement Of Foundation Bolts & Nuts Including Labour , Tools, Tackles Consumeables Like Cement, Sand Aggregates, Etc Complete In All Respect As Per Scope Of Work, Specifications And Direction Of Eic , Part-A-Item - 5 - Repairing Of Mts Including Supply And Replacement Of Damaged Door, Door Locks, Terminal Plate, Diagram Plate, Neoprene Gasket, Brass Links Cable Identification Ferrules Etc In Mts With Proper Cable Termination, Cable Jointing, Lugs, With Numbering Of Ts Complete In All Respect Including Labour, Tools, Tackles, Consumeables Like Ms / Brass Bolts, Nuts, Washers, Insulation Tape Etc.As Per Scope Of Work Specifications And The Direction Of Eic , Part-A-Item - 6 - Supply & Replacement Of Damaged / Missing Locks In Mts Including Labor, Consumables And Tools & Tackles As Per Drawings, Specifications & Instructions Of Eic. , Part-A-Item - 7 - Supply & Installation Of Damaged / Missing Terminal Plates ( All Types ) With M10 Brass Studs, Washers, Links, Lugs & Nuts, Including Labor, Tools & Tackles And Consumables As Per Instruction Of Eic , Part-A-Item - 8 - Supply And Fixing Of Diagram Plate In The Existing Manual Test Station ( All Types ) Complete In All Respect Including Labour, Tools, Tackles, Consumeables Etc. As Per Scope Of Work Specifications And The Direction Of Eic , Part-A-Item - 9 - Identification Of Cables In Test Station: The Cables Inside The Test Station Shall Be Identified As Per Diagram Plate / Sticker By Proper Dressing, Identification Ferrules, Carrying Out Necessary Termination With Copper Lugs Of Required Size And As Per The Direction Of Eic. The Cable Dressing Shall Be Strictly As Per The Diagram Plate , Part-A-Item - 10 - Supply And Fixing Of Neo-Prene Gasket In Mts Box Sizes ( All Types ) As Per Scope Of Work And Directions Of Eic. , Part-A-Item - 11 - Repairing Of Aljb Including Supply Of New Locks & Latch For The Outer Enclosure, Shunt, Variable Resistance, Brass Links, Aljb Doors Including Welding Mechanical, Straightening Of Pipe, Fittings, Hinges, Labour, Tools Tackles, Consumables Like Lugs, Ms / Brass Nuts, Bolts, Washers, Insulation Tape Etc Complete In All Respect As Per Approved Drawings, Specification And As Per Direction Of Eic. , Part-A-Item - 12 - Supply Of Xlpe Armoured Copper Cableof 4 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part-A-Item - 13 - Supply Of Xlpe Armoured Copper Cableof 6 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part-A-Item - 14 - Supply Of Xlpe Armoured Copper Cable Of 10 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part-A-Item - 15 - Supply Of Xlpe Armoured Copper Cableof 25 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part-A-Item - 16 - Supply Of Xlpe Armoured Copper Cableof 35 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part-A-Item - 17 - Cable Laying Of 4 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part-A-Item - 18 - Cable Laying Of6 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part-A-Item - 19 - Cable Laying Of 10 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part-A-Item - 20 - Cable Laying Of 25 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part-A-Item - 21 - Cable Laying Of 35 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part-A-Item - 22 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 4 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part-A-Item - 23 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 6 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part-A-Item - 24 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 10 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part-A-Item - 25 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 25 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part-A-Item - 26 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 35 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part-A-Item - 27 - Making Of Pipe To Cable Connection As Per Approved Procedure, Of All Types Of Cable Including Excavation And Backfilling, Surface Preparation, Pipe To Cable Connection By Means Of Pin Brazing Its Encapsulation, Holiday Testing Of The Exposed Section, Labour, Tools, Tackles Etc As Per Scope Of Work, Specifications And Direction Of Eic . ( Pin Brazing Kit And Holiday Detector Will Be In The Scope Of The Contractor ) . , Part-A-Item - 28 - Painting Of Manual Test Station Including Removing Of Old Paint, Rust Etc Using Emery Paper, Surface Preparation To Get The Smooth Level Surface, Supply And Application Of 01 Coat Of Ready Mix Red Oxide Primer Of Approved Make, 02 Coats Of Ready Mixed First Quality Paint Of Approved Brand. ( Final Dry Paint Thickness Not Less Than 100 Micron ) , Numbering Of Test Station As Per Scope Of Work, Specification And As Per Direction Of Eic. , Part-A-Item - 29 - Painting Of Anode Lead Junction Box Including Removing Of Old Paint, Rust Etc Using Emery Paper, Surface Preparation To Get The Smooth Level Surface, Supply And Application Of 01 Coat Of Ready Mix Red Oxide Primer Of Approved Make, 02 Coats Of Ready Mixed First Quality Paint Of Approved Brand. ( Final Dry Paint Thickness Not Less Than 100 Micron ) , Numbering Of Test Station As Per Scope Of Work, Specification And As Per Direction Of Eic. , Part-A-Item - 30 - Supply & Replacement Of Imported Copper-Copper Sulphate Permanent Refrenece Cells ( Make Mc Miller / Tinker & Rasor Company / Caproco ) Necessary Backfill Material Including Excavation / Backfilling Cable Laying, Cable Identification Ferrules, Labour, Tools, Tackles, Consumables Like Sand, Brick, Lug, Brass Washers, Insulation Tape Etc, Complete In All Respects As Per Scope Of Work Drawings, Specification And Direction Of Eic. , Part-A-Item - 31 - Supply And Installation Of Pre-Packed Magnesium Anodes With Cable Having Weight 17 Pounds Including Excavation, Backfilling, Cable Laying Up To Test Station And Cable Termination In Test Station, Cable Identification Ferrules, With Consumables Labour Etc. As Per Approved Drawing, Specification And Direction Of Eic , Part-A-Item - 32 - Supply , Replacement & Installation Of Prepacked Single Zinc Anode ( 11Kg ) Of Reputed Make Including Excavation, Backfilling, Anode To Tail Cable Connection, Cable Identification, Coke Breeze Backfill Complete With Labor, Tools & Tackles As Per Drawings, Specifications & Instructions Of Eic , Part-A-Item - 33 - Supply And Installation Of Pre Packed Pair Of Zinc Grounding Cell 22Kg Including All Tools, Tackles, Consumables, Labour, Chemical Back Fill, Excavation, Backfilling, Cable To Insert Joint, Laying Of Tail Cable, Cable Termination At Ts Complete And In All Respect As Per Drawing, Specification And As Per Direction Of Eic , Part-A-Item - 34 - Supply Of Earthing Strip 25 Mm X 4 Mm Size: Conducton Material: Gi Conforming To Is Code 2629, Zinc Deposition: Not Less Than 610 Grams / Square Meter, Length Of Strip: Minimum 7 Mtr And Maximum 10Mtr, Thickness Of Zinc Coating: Not Less Than 86 Micron And Smooth, Continuous, Uniform & Free From Acid Spot, Galvanizing Process: Hot Dip Galvanized And As Per Scope Of Work& Specification In All Respect And As Per Instruction Of Eic. , Part-A-Item - 35 - Supply Of Earthing Strip 50 Mm X 6 Mm Size: Conducton Material: Gi Conforming To Is Code 2629, Zinc Deposition: Not Less Than 610 Grams / Square Meter, Length Of Strip: Minimum 7 Mtr And Maximum 10Mtr, Thickness Of Zinc Coating: Not Less Than 86 Micron And Smooth, Continuous, Uniform & Free From Acid Spot, Galvanizing Process: Hot Dip Galvanized And As Per Scope Of Work& Specification In All Respect And As Per Instruction Of Eic. , Part-A-Item - 36 - Laying Of Hot Dip Galvanized Of 25 Mm X 4 Mm Iron Earth Strip In Buried Trench At A Depth Of Minimum Upto 150 Mm From Fgl. Work Includes Civil Work Like Excavation, Breaking Of Pcc / Rcc & Back Filling After Laying Of Earth Strip, Welding Of Joints & Applying 2 Layers Of Bitumen Etc. As Per Scope Of Work & Specfication In All Respect And As Per Instruction Of Eic , Part-A-Item - 37 - Laying Of Hot Dip Galvanized Of 50 Mm X 6 Mm Iron Earth Strip In Buried Trench At A Depth Of Minimum Upto 150 Mm From Fgl. Work Includes Civil Work Like Excavation, Breaking Of Pcc / Rcc & Back Filling After Laying Of Earth Strip, Welding Of Joints & Applying 2 Layers Of Bitumen Etc. As Per Scope Of Work & Specfication In All Respect And As Per Instruction Of Eic , Part-A-Item - 38 - Supply Of Copper Plate Earthing, Tinned Annealed Copper Plate Of Size 600X600x3mm, Tinned Annealed Copper Earthing Strip Of Size 50X6mm, Tinned Annealed Copper Earthing Strip Of Size 25X4mm, Gi Earth Electrode Of Diameter: 50Mm, Thickness: 4.5Mm, Length: 2000Mm, Class-C, Taperred Cut Upto 75Mm From Bottom, Stagerred Hole Of 12Mm Dia 75Mm Apart Upto 1500Mm From Bottom, Removable Cap Of Length 25Mm Made Of 65Mm Dia Pipe With 3Mm Ms Plate Welded To The Top, Funnel With Steel Wite Mesh, Galvanized , Part-A-Item - 39 - Construction Of Earth Pit For Copper Plate Earthing At Sv / Rr / Ip Stations Of Pipeline As Per The Drawing Provided Which Includes Supply Of All Required Materiallike50mm Dia, 2000Mm Long Earth Electrode, 600 X 600 X 6Mm Copper Plate & 25 X 4Mm Copper Strip Including Excavation, Brick Work, Pcc, Supply Of Charcoal, Salt, Sand, Ms Chequered Plate Of 6Mm Thickness , Copper Cable, Bolt, Nuts / Check Nuts, Funnel, Back Filling Compound For Filling Around The Electrode, And Excavation Of Pit As Per Drawing Up To A Depth Of 3.5 Meter Minimum, Making Of Pit With Brick, Sand, Cement & Smooth Plastering, Fixing Of Ms Cover 6Mm Thickness, Termination Of Earth Wire / Cable / Strip & Connect Earth Pit With Grid And Also Ensure Continuity With Grid. , Part-A-Item - 40 - Construction Of Normal Earth Pit Scope Of Woks Includes Erection & Commissioning Ofearth Pits At Sv / Rr / Ip Stations Of Pipeline Wherever It Is Required Which Includes Supply Of All Required Material As Per Specification Like- 75 Mm Dia, 4.5 Mm Thickeness Earthelectrode, Gi Strip, Copper Cable, Bolt, Nuts / Check Nuts, Funnel, Back Filling Compound For Filling Around The Electrode, And Excavation Of Pit As Per Drawing Up To A Depth Of 3.5 Meter Minimum, Making Of Pit With Brick, Sand, Cement & Smooth Plastering, Fixing Of Ms Cover 6Mm Thickness, Termination Of Earth Wire / Cable / Strip & Connect Earth Pit With Grid And Also Ensure Continuity With Grid , Part-A-Item - 41 - Construction Of Chemical Earth Pit: Scope Of Woks Includes Erection & Commissioning Of Chemical Earth Pits At Sv / Rr / Ip Stations Of Pipeline Wherever It Is Required Which Includes Supply Of All Required Material As Per Specification Like- Electrode, Gi Strip, Copper Cable, Bolt, Nuts / Check Nuts, Funnel, Back Filling Compound For Filling Around The Electrode, And Excavation Of Pit As Per Drawing Up To A Depth Of 3.5 Meter Minimum, Making Of Pit With Brick, Sand, Cement & Smooth Plastering, Fixing Of Ms Cover 6Mm Thickness, Termination Of Earth Wire / Cable / Strip & Connect Earth Pit With Grid And Also Ensure Continuity With Grid In All Respect As Per The Scope Of Work And Drawings And As Per Instruction Of Eic. , Part-A-Item - 42 - Supply Ofearth Pit Chamber Ms Cover Of 6 Mm Thickness , Part-A-Item - 43 - Preventive Maintenance Of Anode Ground Bed -The Scope Of Work Includes Necessary Excavation For Carrying Out Ground Bed Curing With 500 Kg Of Common Salt And Water Of 18 Kl. The Work Includes Necessary Backfilling And Restoration To The Original Condition As Per The Direction Of Eic. The Contractor Shall Measure The Grounded Resistance After The Treatment Of Ground Bed. The Resistance Of Grounded After The Maintenance Shall Be Less Than 01 Ohm. Clearance If Any Required From Land Owner For Entering / Working In His Permisses Will Be In The Contractors Scope , Part-A-Item - 44 - Supply And Installation Of Cable Markers ( Ci / Cs / Ms ) For Underground Cables And Equipment As Per The Scope Of Work And Specfication In All Respect And As Per The Instruction Of Eic. , Part-A-Item - 45 - Carrying Out On-Off Close Interval Potential Survey ( Cipl ) With Lateral Gradient At One Meter Interval Using Data Loggers And Standard Cu / Cuso4 Reference Electrode Including Detailed Reports And As Per The Scope Of The Work And Specification In All Respect And As Per Instrution Of Eic. , Part-A-Item - 46 - Stray Current Interference Survey At Railway Crossing Or Runnig Parallel To Gail Pipelines, Including 24 Hours Data Logging, Data Collection From Railways, Study The Effectiveness Of Existing Diode Bonding And Recommend Mitigation Measures / Modification Required At Existing Doide Jb, At All The Railway Crossings Or Running Parallel As Defined In Scope Of Work With Specification, Design And Detail Engineering In All Respect And As Per Instruction Of Eic. , Part-A-Item - 47 - Stray Current Interference Survey At Foreign P / L Crossing Or Runnig Parallel With Gail Pipeline, Including 24 Hours Data Logging, Data Collection From Foreign Pipeline Operator, And Recommend Mitigation Measures At Foreign Pipeline Crossing Or Running Parallel To Gail Pipeline As Defined In The Scope Of Work, With Design, Specification And Detail Enggineering In All Respect And As Per Instruction Of Eic. , Part-A-Item - 48 - Stray Current Interference Survey At Ht Crossings Or Runnig Parallel To Gail Pipelines, Including 24 Hours Data Logging, Collection Of Data From Seb, Calculation Of Human Touch And Step Voltages, Measurent And Calculation Of Ac Corrossion Current And Recommendation For Mitigation / Effectiveness Of Existing Grounding With Modification If Required, At Ht Line Crossings / Parallel Sections As Defined In The Scope Of Work With Design, Specification And Detail Enggineering In All Respect And As Per Instruction Of Eic.. , Part-A-Item - 49 - Adequacy Of Cp Station , Study The Adequacy Of Existing Cp Stations ( Cptr & Cppsm ) , Including Effectiveness And Efficiency Of Remote Anode Bed, Effective Span Of Polarised Protection On The Pipelines From The Drain Point, Mode Of Operation For The Purpose Of Adequacy And Better Operation Of The Cp System And As Defined In The Scope Of Work In All Respect And As Per Instruction Of Eic.. , Part-A-Item - 50 - Carryingout Current Attenuation Test / Direct Current Voltage Gradient ( Dcvg ) Survey Using Standard Dcvg Equipment To Pin Point The Coating Defect / Holidays On Pipeline As Per The Specifications In All Respect And As Per Instruction Of Eic.. , Part-A-Item - 51 - Excavation Of Pipeline In All Type Of Soils And Ordinary Rocks For A Width Of D+500 Mm On Each Side Of Pipe And Exposing The Pipeline From Top Upto 500 Mm Below The Bottom Of Pipeline Including The Stacking Of Excavated Earth, Stacked Earth To Be Levelled And Neatly Dressed As Per The Scope Of Work And Directions Of Eic , Part-A-Item - 52 - Backfilling Excavated Earth ( Excluding Rock ) In Trenches In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, As Per The Scope Of Work And Directions Of Eic. , Part-A-Item - 53 - Supply Of Cold Applied Tape, 100 Mm, Innerwrap As Per The Specifications , Scope Of Work And Directions Of Eic , Part-A-Item - 54 - Supply Of Cold Applied Tape, 100 Mm, Outerwrap As Per The Specifications , Scope Of Work And Directions Of Eic , Part-A-Item - 55 - Supply Ofprimer, Cold Tape Coating, Din 30762 Part As Per The Specifications , Scope Of Work And Directions Of Eic , Part-A-Item - 56 - Supply Oftap, Mastic, Roll As Per The Specifications , Scope Of Work And Directions Of Eic , Part-A-Item - 57 - Coating Repair- Removing The Old / Damaged Coating / Rust Greese, Moisture And All Foreign Material At Defect Location With Scrapper, Manual Surface Preparation Using Hand Wire Brush, Emery Paper, Scrappers Or A Combination Of All Processes, Repairng Of The Coating With Supply Of Raychem Sleeves / Cold Applied Tape / Perp / Patch Repair Kit, Holiday Testing After Repair, As Per The Scope Of Work And To The Entire Satisfaction Of Eic. Multiple Patch Repairing At One Location Within One Meter Span Shall Be Trated As Single Quantity Only. Coating Material Will Be Supplied By Gail. ( Compensation, If Required To Land Owners Shall Be In The Scope Of Contractor ) , Part-A-Item - 58 - Supply & Installation Of Surge Diverters ( Dehn / Equivalent ) In Mts At Ht Power Line Crossings Including Cable Identification, Labor, Tools & Tackles, Brass Studs / Nuts And Sundry Consumables , Part-A-Item - 59 - Supply & Installation Of Explsoin Proof Spark Gap Arrestors Of Dehn Exsg4 / Equivalent Make Across Insulating Joints At Sv / Ip / Rr / Terminals Including Required Cable ( 25Sqmm, Cu ) , Lugs, Nuts & Bolts, Labor, Tools & Tackles, And Sundry Consumables , Part-A-Item - 60 - Supply Of Portable Cu-Cuso4 Half Cell For Measuring Of Psp ( Pipe To Soil Potential ) Of Pipeline , Part-A-Item - 61 - Anode Lead Junction Box ( Size :-500 X 700 X 250 ) Supply, Installation, Testing And Commissioning Of Anode Lead Junction Box Including Required Backelite Plate Brass Nut Bolts, Port Type Resistor & Shunt Arrangement, Civil Works With Materials As Per Eic , Part-A-Item - 62 - Reconditioning / Recharging / Maintenance Of Existing Earth Pit At Rr / Terminals With Raising The Height Of Civil Foundation, Repair Of Cement Plastering, Painting Of Top Cover Plates And Numbering Of Earthpits. Supply Of Common Salt 50 Kg And Water 100L For Bringing Down The Circuit Resistance Including Making Necessary Excavation, Mixing & Pouring Of Salt & Water, Replacement & Cleaning Of Connecting Nuts And Bolts, Etc Complete In All Respect And As Per Directions Of Eic , Part-A-Item - 63 - Installation & Commissioning Of Gail Supplied Corrosion Censing Probe At Sv / Rr Stations Of Hvj Pipeline In All Kind Of Soil Including Excavation, Installation, Termination In Manual Test Stations And Backfilling / Restoration To The Original Ground Condition Under Dibiyapur Region As Per Scope Of Work And Direction Of Eic. , Part-A-Item - 64 - Bell Hole Inspection: Excavation In All Type Of Soils And Ordinary Rocks For A Width Of D+500 Mm On Each Side Of Pipe And Exposing The Pipeline From Top Upto 500 Mm Below The Bottom Of Pipeline Including The Stacking Of Excavated Earth On Pipeline For Bell Hole Inspection For Checking The Health Of Pipeline Including Backfilling & Restoration To Original Condition In All Respect As Per Direction Of Eic. , Part-A-Item - 65 - Supply Installation & Commissioning Of Sspc ( Solid State Polarisation Cell ) In New Installation / Existing System In Case Of Damaged As Per Ace / Vde Specifications For Protection Of Hv / Ehv Power Lines Crossings, Iccc ( Rustroll System ) , Dairyland Or Equivalent Make ( As Approved By Eic ) Suitable For Arresting Induce Ac Fault Currents, Lightning & Surge Protection, Dc Voltage ( > 3 Volts ) And Blocking The Protective Cathodic Protection Current On The Pipeline. Supply Of Sspc, ( As Per Specification Mentioned In This Tender Documents ) , Test Station Of Suitable Size, Required Length & Size Of Cable, Consumables With Testing & Data Logging Before And After Installation ( Report To Be Submitted ) Are In The Scope Of Contractor. Complete In All Respect And As Per Direction, Specification Of Eic , Part-A-Item - 66 - Soil Resistivity Survey By Wenner Four Point Method , Part-A-Item - 67 - Supply And Installation Of End Seals Of Both Side Of Casings Upto 6 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part-A-Item - 68 - Supply And Installation Of End Seals Of Both Side Of Casings For 18 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part-A-Item - 69 - Supply And Installation Of End Seals Of Both Side Of Casings For 12 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part-A-Item - 70 - Supply And Installation Of End Seals Of Both Side Of Casings For 24 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part-A-Item - 71 - Supply And Installation Of End Seals Of Both Side Of Casings For 30 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part-A-Item - 72 - Rectification Of Short Casing , Part-A-Item - 73 - Maintenance Of Lightning System ( Outdoor ) Maintenance Of Lighting System At Rr / Sv Station Under Dibiyapur Region. ( Height Of Pole Upto 12 M ) . All Consumable Materials, Ladder, Manpower, Vehicle Required For Maintenance Of Street Pole Light Will Under Scope Of Vendor. , Part-A-Item - 74 - Supply & Installation Of Distribution Box :Supply & Installation Of Distribution Box With 63A / 100A Tpmccb, Bakelite Fuse, Bus Bar, Neutral Link In M.S. Sheet Enclosure Of Size Not Less Than 500X750x200mm With Enamel Painting And Cable Entry Holes With Lockable Door. All Mentioned Items Will Be In Scope Of Vendor. , Part-A-Item - 75 - Supply, Installation & Commissioning Of Polarization Coupon Along With Magnetic Reed Switch As Per The Scope Of Work , Part-A-Item - 76 - Supply Of Solar Charge Contr. 12V / 10A Dc At Sv Stations : Scope Of Work Shall Include Supply And Installation Of Solar Charge Controller For Pole Mounted Solar Light, 12V Dc, 10A ( As Per Installed System ) As Per Direction, Specification & Satisfaction Of Eic , Part-A-Item - 77 - Supply Of Solar Charge Contr.Solar Plant: Scope Of Work Shall Include Supply And Installation Of Solar Charge Controller For Solar Plant, 96V Dc / 100A Or 120V Dc / 100A, 48V Dc / 180A ( As Per Installed System ) As Per Direction, Specification & Satisfaction Of Eic. , Part-A-Item - 78 - Supply Of Dc / Dc Converter At Rr Station : Scope Of Work Should Include Supply And Installation Of Dc-Dc Converter At Rr / Ip Stations Under Dibiyapur. Input 30 V-70 V. Ouput 48 V , 21A. The Quanity Mentioned Against Each Maintenance Basemay Be Used In Other Region If Required. , Part-A-Item - 79 - Permission From Statuary Authority: Scope Of Work Shall Include Granting Permission From Statuary Authority ( Railways / Highway / Forest / Any Government Related Authority ) For Any Kind Of Job In Their Rou Or In Forest Land As Per Requirement Of Gail. Transportation And Other Expenses Involved In The Job Shall Be In The Scope Of Contractor , Part-A-Item - 80 - Preventive Maintenance Of Window / Spilt Preventive Maintenance Of Window / Spilit A / C Upto 3 Tons As Per Scope Of Work , Part-A-Item - 81 - Preventive Maintenance Of Water Coolers Preventive Maintenance Of Water Coolers Up To 150 Ltrs As Per Scope Of Work , Part-A-Item - 82 - Preventive Maintenance Of Refrigerator / D Preventive Maintenance Of Refrigerators / Deep Freezers Upto 350 Ltrs As Per Scope Of Work , Part-A-Item - 83 - Sitc Of Starting Capacitor ( 80-100Mfd ) , Part-A-Item - 84 - Sitc Of Running Capacitor ( 36 Mfd ) , Part-A-Item - 85 - Sitc Of Starting Relay For A / C, Wc, Rg , Part-A-Item - 86 - Sitc Of Thermostat , Part-A-Item - 87 - Sitc Of Over Load Relay A / C, Wc, Rg , Part-A-Item - 88 - Sitc Of Shaft For Blower Motor , Part-A-Item - 89 - Sitc Of Bush For Blower Motor , Part-A-Item - 90 - Sitc Of Float Valve For Water Cooler , Part-A-Item - 91 - Sitc Of Fan Blade For Condenser , Part-A-Item - 92 - Sitc Of Selector / Rotary Switch A / C , Part-A-Item - 93 - Sitc Of Air Filter For Cooling Coil Of A Sitc Of Air Filter For Cooling Coil Of A / C , Part-A-Item - 94 - Sitc Of Blower For A / C , Part-A-Item - 95 - Sitc Of The Faulty Compressor Of Window / Split Sitc Of The Faulty Compressor Of Window / Split Ac Upto 3 Ton With New One In Buyback Scheme Of Old Burnet Compressor As Per Scope Of Work And Direction Of Eic , Part-A-Item - 96 - Sitc Of The Faulty Compressor Of Refrige Sitc Of The Faulty Compressor Of Refrigerator / Water Cooler Upto 350 Ltr. With New One In Buyback Scheme Of Old Burnet Compressor As Per Scope Of Work And Direction Of Eic , Part-A-Item - 97 - Sitc Of The Control Card For Single Ph Sitc Of The Control Card For Single Phase Window / Split Ac As Per Scope Of Work And Direction Of Eic , Part-A-Item - 98 - Sitc Of Capillary / Copper Pipe Require Fo Sitc Of Capillary / Copper Pipe Require For Window / Split Ac , Water Cooler Refregerator Application As Per Scope Of Work And Direction Of Eic , Part-A-Item - 99 - Supply And Charging Of Refregient Gas To Supply And Charging Of Refregient Gas To The Compressor Of Split / Window Ac / Refregerator / Water Cooler As Per Scope Of Work And Direction Of Eic Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 2.00 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
44.
Petroleum and Natural Gas #4904356 AOC
Bids Are Invited For Part - C -Item-1 - Supply & Installation Of Manual Test Stations ( Mts ) Complete With Lower Bend And With Pcc Foundation Including, Terminal Plate, Diagram Plate, Cable Identification Ferrules, & Proper Cable Termination With Lugs, Numbering Of Ts Etc. As Per Drawing & Specification ( With Ip55 ) Complete In All Respect And Per Instruction Of Eic , Part - C -Item-2 - Supply & Installation Of Manual Test Stations ( Mts ) Without Lower Bend & Without Pcc Foundation Including Terminal Plate, Diagram Plate, Cable Identification Ferrules & Proper Cable Termination With Lugs, Numbering Of Ts Etc. As Per Drawing & Specification ( With Ip55 ) Complete In All Respect And Per Instruction Of Eic. , Part - C -Item-3 - Shifting Of Mts Along With Foundation And Cable To Suitable Nearby Location As Per Instruction Of Eic. ( Cable Extra ) , Part - C -Item-4 - Repairing Of Mts Foundation With Supply And Replacement Of Foundation Bolts & Nuts Including Labour , Tools, Tackles Consumeables Like Cement, Sand Aggregates, Etc Complete In All Respect As Per Scope Of Work, Specifications And Direction Of Eic , Part - C -Item-5 - Repairing Of Mts Including Supply And Replacement Of Damaged Door, Door Locks, Terminal Plate, Diagram Plate, Neoprene Gasket, Brass Links Cable Identification Ferrules Etc In Mts With Proper Cable Termination, Cable Jointing, Lugs, With Numbering Of Ts Complete In All Respect Including Labour, Tools, Tackles, Consumeables Like Ms / Brass Bolts, Nuts, Washers, Insulation Tape Etc.As Per Scope Of Work Specifications And The Direction Of Eic , Part - C -Item-6 - Supply & Replacement Of Damaged / Missing Locks In Mts Including Labor, Consumables And Tools & Tackles As Per Drawings, Specifications & Instructions Of Eic. , Part - C -Item-7 - Supply & Installation Of Damaged / Missing Terminal Plates ( All Types ) With M10 Brass Studs, Washers, Links, Lugs & Nuts, Including Labor, Tools & Tackles And Consumables As Per Instruction Of Eic , Part - C -Item-8 - Supply And Fixing Of Diagram Plate In The Existing Manual Test Station ( All Types ) Complete In All Respect Including Labour, Tools, Tackles, Consumeables Etc. As Per Scope Of Work Specifications And The Direction Of Eic , Part - C -Item-9 - Identification Of Cables In Test Station: The Cables Inside The Test Station Shall Be Identified As Per Diagram Plate / Sticker By Proper Dressing, Identification Ferrules, Carrying Out Necessary Termination With Copper Lugs Of Required Size And As Per The Direction Of Eic. The Cable Dressing Shall Be Strictly As Per The Diagram Plate , Part - C -Item-10 - Supply And Fixing Of Neo-Prene Gasket In Mts Box Sizes ( All Types ) As Per Scope Of Work And Directions Of Eic. , Part - C -Item-11 - Repairing Of Aljb Including Supply Of New Locks & Latch For The Outer Enclosure, Shunt, Variable Resistance, Brass Links, Aljb Doors Including Welding Mechanical, Straightening Of Pipe, Fittings, Hinges, Labour, Tools Tackles, Consumables Like Lugs, Ms / Brass Nuts, Bolts, Washers, Insulation Tape Etc Complete In All Respect As Per Approved Drawings, Specification And As Per Direction Of Eic. , Part - C -Item-12 - Supply Of Xlpe Armoured Copper Cableof 4 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - C -Item-13 - Supply Of Xlpe Armoured Copper Cableof 6 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - C -Item-14 - Supply Of Xlpe Armoured Copper Cableof 10 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - C -Item-15 - Supply Of Xlpe Armoured Copper Cableof 25 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - C -Item-16 - Supply Of Xlpe Armoured Copper Cableof 35 Sq Mm As Per Scope Of Work, Specifications And Direction Of Eic , Part - C -Item-17 - Cable Laying Of 4 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - C -Item-18 - Cable Laying Of 6 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - C -Item-19 - Cable Laying Of 10 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - C -Item-20 - Cable Laying Of 25 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - C -Item-21 - Cable Laying Of 35 Sq Mm ( Xlpe Armoured Cable ) Inside The Test Station / Over Ground & Under Ground / Inside The Panel Including Excavation And Backfilling, Cable Laying Cable Jointing Above Ground Using Copper Sleeves, Termination Of Cable In Test Station / Panel, Cable Identification, Supply & Laying Of Bricks, Sand Etc Including Tools Tackles, Labour, Consumables As Per Scope Of Work, Specifications And The Direction Of Eic , Part - C -Item-22 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 4 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - C -Item-23 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 6 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - C -Item-24 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 10 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - C -Item-25 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 25 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - C -Item-26 - Cable Jointing / Repairing Of Underground Cable As Per Approved Procedure Including Excavation And Backfilling, Cable Jointing By Cable Jointing Kit ( Raychem / Equivalent ) , Termination & Identification Of Cables, Supply Of Cable Jointing Kit & Other Consumable, Labour, Tools, Tackles, Copper Sleeves, Heat Shrink Sleeves, Ferol Etc. For 35 Sq Mm. Xlpe Armoured Cu Cable As Per Scope Of Work, Specifications And Directions Of Eic , Part - C -Item-27 - Making Of Pipe To Cable Connection As Per Approved Procedure, Of All Types Of Cable Including Excavation And Backfilling, Surface Preparation, Pipe To Cable Connection By Means Of Pin Brazing Its Encapsulation, Holiday Testing Of The Exposed Section, Labour, Tools, Tackles Etc As Per Scope Of Work, Specifications And Direction Of Eic . ( Pin Brazing Kit And Holiday Detector Will Be In The Scope Of The Contractor ) . , Part - C -Item-28 - Painting Of Manual Test Station Including Removing Of Old Paint, Rust Etc Using Emery Paper, Surface Preparation To Get The Smooth Level Surface, Supply And Application Of 01 Coat Of Ready Mix Red Oxide Primer Of Approved Make, 02 Coats Of Ready Mixed First Quality Paint Of Approved Brand. ( Final Dry Paint Thickness Not Less Than 100 Micron ) , Numbering Of Test Station As Per Scope Of Work, Specification And As Per Direction Of Eic. , Part - C -Item-29 - Painting Of Anode Lead Junction Box Including Removing Of Old Paint, Rust Etc Using Emery Paper, Surface Preparation To Get The Smooth Level Surface, Supply And Application Of 01 Coat Of Ready Mix Red Oxide Primer Of Approved Make, 02 Coats Of Ready Mixed First Quality Paint Of Approved Brand. ( Final Dry Paint Thickness Not Less Than 100 Micron ) , Numbering Of Test Station As Per Scope Of Work, Specification And As Per Direction Of Eic. , Part - C -Item-30 - Painting Of Tr Unit Including Removing Of Old Paint, Rust Etc Using Emery Paper, Surface Preparation To Get The Smooth Level Surface, Supply And Application Of 01 Coat Of Ready Mix Red Oxide Primer Of Approved Make, 02 Coats Of Ready Mixed First Quality Paint Of Approved Brand. ( Final Dry Paint Thickness Not Less Than 100 Micron ) , Numbering Of Test Station As Per Scope Of Work, Specification And As Per Direction Of Eic. , Part - C -Item-31 - Supply & Replacement Of Imported Copper-Copper Sulphate Permanent Refrenece Cells ( Make Mc Miller / Tinker & Rasor Company / Caproco ) Necessary Backfill Material Including Excavation / Backfilling Cable Laying, Cable Identification Ferrules, Labour, Tools, Tackles, Consumables Like Sand, Brick, Lug, Brass Washers, Insulation Tape Etc, Complete In All Respects As Per Scope Of Work Drawings, Specification And Direction Of Eic. , Part - C -Item-32 - Supply And Installation Of Pre-Packed Magnesium Anodes With Cable Having Weight 17 Pounds Including Excavation, Backfilling, Cable Laying Up To Test Station And Cable Termination In Test Station, Cable Identification Ferrules, With Consumables Labour Etc. As Per Approved Drawing, Specification And Direction Of Eic , Part - C -Item-33 - Supply , Replacement & Installation Of Prepacked Single Zinc Anode ( 11Kg ) Of Reputed Make Including Excavation, Backfilling, Anode To Tail Cable Connection, Cable Identification, Coke Breeze Backfill Complete With Labor, Tools & Tackles As Per Drawings, Specifications & Instructions Of Eic , Part - C -Item-34 - Supply And Installation Of Pre Packed Pair Of Zinc Grounding Cell 22Kg Including All Tools, Tackles, Consumables, Labour, Chemical Back Fill, Excavation, Backfilling, Cable To Insert Joint, Laying Of Tail Cable, Cable Termination At Ts Complete And In All Respect As Per Drawing, Specification And As Per Direction Of Eic , Part - C -Item-35 - Supply Of Earthing Strip 25 Mm X 4 Mm Size: Conducton Material: Gi Conforming To Is Code 2629, Zinc Deposition: Not Less Than 610 Grams / Square Meter, Length Of Strip: Minimum 7 Mtr And Maximum 10Mtr, Thickness Of Zinc Coating: Not Less Than 86 Micron And Smooth, Continuous, Uniform & Free From Acid Spot, Galvanizing Process: Hot Dip Galvanized And As Per Scope Of Work& Specification In All Respect And As Per Instruction Of Eic. , Part - C -Item-36 - Supply Of Earthing Strip 50 Mm X 6 Mm Size: Conducton Material: Gi Conforming To Is Code 2629, Zinc Deposition: Not Less Than 610 Grams / Square Meter, Length Of Strip: Minimum 7 Mtr And Maximum 10Mtr, Thickness Of Zinc Coating: Not Less Than 86 Micron And Smooth, Continuous, Uniform & Free From Acid Spot, Galvanizing Process: Hot Dip Galvanized And As Per Scope Of Work& Specification In All Respect And As Per Instruction Of Eic. , Part - C -Item-37 - Laying Of Hot Dip Galvanized Of 25 Mm X 4 Mm Iron Earth Strip In Buried Trench At A Depth Of Minimum Upto 150 Mm From Fgl. Work Includes Civil Work Like Excavation, Breaking Of Pcc / Rcc & Back Filling After Laying Of Earth Strip, Welding Of Joints & Applying 2 Layers Of Bitumen Etc. As Per Scope Of Work & Specfication In All Respect And As Per Instruction Of Eic , Part - C -Item-38 - Laying Of Hot Dip Galvanized Of 50 Mm X 6 Mm Iron Earth Strip In Buried Trench At A Depth Of Minimum Upto 150 Mm From Fgl. Work Includes Civil Work Like Excavation, Breaking Of Pcc / Rcc & Back Filling After Laying Of Earth Strip, Welding Of Joints & Applying 2 Layers Of Bitumen Etc. As Per Scope Of Work & Specfication In All Respect And As Per Instruction Of Eic , Part - C -Item-39 - Construction Of Normal Earth Pit Scope Of Woks Includes Erection & Commissioning Ofearth Pits At Sv / Rr / Ip Stations Of Pipeline Wherever It Is Required Which Includes Supply Of All Required Material As Per Specification Like- 75 Mm Dia, 4.5 Mm Thickeness Earthelectrode, Gi Strip, Copper Cable, Bolt, Nuts / Check Nuts, Funnel, Back Filling Compound For Filling Around The Electrode, And Excavation Of Pit As Per Drawing Up To A Depth Of 3.5 Meter Minimum, Making Of Pit With Brick, Sand, Cement & Smooth Plastering, Fixing Of Ms Cover 6Mm Thickness, Termination Of Earth Wire / Cable / Strip & Connect Earth Pit With Grid And Also Ensure Continuity With Grid , Part - C -Item-40 - Construction Of Chemical Earth Pit: Scope Of Woks Includes Erection & Commissioning Of Chemical Earth Pits At Sv / Rr / Ip Stations Of Pipeline Wherever It Is Required Which Includes Supply Of All Required Material As Per Specification Like- Electrode, Gi Strip, Copper Cable, Bolt, Nuts / Check Nuts, Funnel, Back Filling Compound For Filling Around The Electrode, And Excavation Of Pit As Per Drawing Up To A Depth Of 3.5 Meter Minimum, Making Of Pit With Brick, Sand, Cement & Smooth Plastering, Fixing Of Ms Cover 6Mm Thickness, Termination Of Earth Wire / Cable / Strip & Connect Earth Pit With Grid And Also Ensure Continuity With Grid In All Respect As Per The Scope Of Work And Drawings And As Per Instruction Of Eic. , Part - C -Item-41 - Supply Ofearth Pit Chamber Ms Cover Of 6 Mm Thickness , Part - C -Item-42 - Preventive Maintenence Of Polarisation Cells / Kirk Cells Supply Of Koh Electrolyte, Complete In All Respect To Make The Cell In Working Condition And As Per Specifications And Instructions Of Eic , Part - C -Item-43 - Preventive Maintenance Of Anode Ground Bed -The Scope Of Work Includes Necessary Excavation For Carrying Out Ground Bed Curing With 500 Kg Of Common Salt And Water Of 18 Kl. The Work Includes Necessary Backfilling And Restoration To The Original Condition As Per The Direction Of Eic. The Contractor Shall Measure The Grounded Resistance After The Treatment Of Ground Bed. The Resistance Of Grounded After The Maintenance Shall Be Less Than 01 Ohm. Clearance If Any Required From Land Owner For Entering / Working In His Permisses Will Be In The Contractors Scope , Part - C -Item-44 - Supply And Installation Of Cable Markers ( Ci / Cs / Ms ) For Underground Cables And Equipment As Per The Scope Of Work And Specfication In All Respect And As Per The Instruction Of Eic. , Part - C -Item-45 - Carrying Out On-Off Close Interval Potential Survey ( Cipl ) With Lateral Gradient At One Meter Interval Using Data Loggers And Standard Cu / Cuso4 Reference Electrode Including Detailed Reports And As Per The Scope Of The Work And Specification In All Respect And As Per Instrution Of Eic. , Part - C -Item-46 - Stray Current Interference Survey At Railway Crossing Or Runnig Parallel To Gail Pipelines, Including 24 Hours Data Logging, Data Collection From Railways, Study The Effectiveness Of Existing Diode Bonding And Recommend Mitigation Measures / Modification Required At Existing Doide Jb, At All The Railway Crossings Or Running Parallel As Defined In Scope Of Work With Specification, Design And Detail Engineering In All Respect And As Per Instruction Of Eic. , Part - C -Item-47 - Stray Current Interference Survey At Foreign P / L Crossing Or Runnig Parallel With Gail Pipeline, Including 24 Hours Data Logging, Data Collection From Foreign Pipeline Operator, And Recommend Mitigation Measures At Foreign Pipeline Crossing Or Running Parallel To Gail Pipeline As Defined In The Scope Of Work, With Design, Specification And Detail Enggineering In All Respect And As Per Instruction Of Eic. , Part - C -Item-48 - Stray Current Interference Survey At Ht Crossings Or Runnig Parallel To Gail Pipelines, Including 24 Hours Data Logging, Collection Of Data From Seb, Calculation Of Human Touch And Step Voltages, Measurent And Calculation Of Ac Corrossion Current And Recommendation For Mitigation / Effectiveness Of Existing Grounding With Modification If Required, At Ht Line Crossings / Parallel Sections As Defined In The Scope Of Work With Design, Specification And Detail Enggineering In All Respect And As Per Instruction Of Eic.. , Part - C -Item-49 - Adequacy Of Cp Station , Study The Adequacy Of Existing Cp Stations ( Cptr & Cppsm ) , Including Effectiveness And Efficiency Of Remote Anode Bed, Effective Span Of Polarised Protection On The Pipelines From The Drain Point, Mode Of Operation For The Purpose Of Adequacy And Better Operation Of The Cp System And As Defined In The Scope Of Work In All Respect And As Per Instruction Of Eic.. , Part - C -Item-50 - Carryingout Current Attenuation Test / Direct Current Voltage Gradient ( Dcvg ) Survey Using Standard Dcvg Equipment To Pin Point The Coating Defect / Holidays On Pipeline As Per The Specifications In All Respect And As Per Instruction Of Eic.. , Part - C -Item-51 - Excavation Of Pipeline In All Type Of Soils And Ordinary Rocks For A Width Of D+500 Mm On Each Side Of Pipe And Exposing The Pipeline From Top Upto 500 Mm Below The Bottom Of Pipeline Including The Stacking Of Excavated Earth, Stacked Earth To Be Levelled And Neatly Dressed As Per The Scope Of Work And Directions Of Eic , Part - C -Item-52 - Backfilling Excavated Earth ( Excluding Rock ) In Trenches In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, As Per The Scope Of Work And Directions Of Eic. , Part - C -Item-53 - Coating Repair- Removing The Old / Damaged Coating / Rust Greese, Moisture And All Foreign Material At Defect Location With Scrapper, Manual Surface Preparation Using Hand Wire Brush, Emery Paper, Scrappers Or A Combination Of All Processes, Repairng Of The Coating With Supply Of Raychem Sleeves / Cold Applied Tape / Perp / Patch Repair Kit, Holiday Testing After Repair, As Per The Scope Of Work And To The Entire Satisfaction Of Eic. Multiple Patch Repairing At One Location Within One Meter Span Shall Be Trated As Single Quantity Only. Coating Material Will Be Supplied By Gail. ( Compensation, If Required To Land Owners Shall Be In The Scope Of Contractor ) , Part - C -Item-54 - Supply & Installation Of Surge Diverters ( Dehn / Equivalent ) In Mts At Ht Power Line Crossings Including Cable Identification, Labor, Tools & Tackles, Brass Studs / Nuts And Sundry Consumables , Part - C -Item-55 - Supply & Installation Of Explsoin Proof Spark Gap Arrestors Of Dehn Exsg4 / Equivalent Make Across Insulating Joints At Sv / Ip / Rr / Terminals Including Required Cable ( 25Sqmm, Cu ) , Lugs, Nuts & Bolts, Labor, Tools & Tackles, And Sundry Consumables , Part - C -Item-56 - Supply Of Portable Cu-Cuso4 Half Cell For Measuring Of Psp ( Pipe To Soil Potential ) Of Pipeline , Part - C -Item-57 - Anode Lead Junction Box ( Size :-500 X 700 X 250 ) Supply, Installation, Testing And Commissioning Of Anode Lead Junction Box Including Required Backelite Plate Brass Nut Bolts, Port Type Resistor & Shunt Arrangement, Civil Works With Materials As Per Eic , Part - C -Item-58 - Reconditioning / Recharging / Maintenance Of Existing Earth Pit At Rr / Terminals With Raising The Height Of Civil Foundation, Repair Of Cement Plastering, Painting Of Top Cover Plates And Numbering Of Earthpits. Supply Of Common Salt 50 Kg And Water 100L For Bringing Down The Circuit Resistance Including Making Necessary Excavation, Mixing & Pouring Of Salt & Water, Replacement & Cleaning Of Connecting Nuts And Bolts, Etc Complete In All Respect And As Per Directions Of Eic , Part - C -Item-59 - Installation & Commissioning Of Gail Supplied Corrosion Censing Probe At Sv / Rr Stations Of Hvj Pipeline In All Kind Of Soil Including Excavation, Installation, Termination In Manual Test Stations And Backfilling / Restoration To The Original Ground Condition Under Dibiyapur Region As Per Scope Of Work And Direction Of Eic. , Part - C -Item-60 - Bell Hole Inspection: Excavation In All Type Of Soils And Ordinary Rocks For A Width Of D+500 Mm On Each Side Of Pipe And Exposing The Pipeline From Top Upto 500 Mm Below The Bottom Of Pipeline Including The Stacking Of Excavated Earth On Pipeline For Bell Hole Inspection For Checking The Health Of Pipeline Including Backfilling & Restoration To Original Condition In All Respect As Per Direction Of Eic. , Part - C -Item-61 - Supply Installation & Commissioning Of Sspc ( Solid State Polarisation Cell ) In New Installation / Existing System In Case Of Damaged As Per Ace / Vde Specifications For Protection Of Hv / Ehv Power Lines Crossings, Iccc ( Rustroll System ) , Dairyland Or Equivalent Make ( As Approved By Eic ) Suitable For Arresting Induce Ac Fault Currents, Lightning & Surge Protection, Dc Voltage ( > 3 Volts ) And Blocking The Protective Cathodic Protection Current On The Pipeline. Supply Of Sspc, ( As Per Specification Mentioned In This Tender Documents ) , Test Station Of Suitable Size, Required Length & Size Of Cable, Consumables With Testing & Data Logging Before And After Installation ( Report To Be Submitted ) Are In The Scope Of Contractor. Complete In All Respect And As Per Direction, Specification Of Eic , Part - C -Item-62 - Soil Resistivity Survey By Wenner Four Point Method , Part - C -Item-63 - Supply And Installation Of End Seals Of Both Side Of Casings For 12 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part - C -Item-64 - Supply And Installation Of End Seals Of Both Side Of Casings For 24 Carrier Pipes Including Making Suitable Trench Necessary Excavation Upto To Pipe Around 1.5 Mtrs, Expose, Replace & Backfilling Complete In All Respect As Per Instructions Of Eic And As Per Scope Of Work , Part - C -Item-65 - Rectification Of Short Casing , Part - C -Item-66 - Maintenance Of Lightning System ( Outdoor ) Maintenance Of Lighting System At Rr / Sv Station Under Dibiyapur Region. ( Height Of Pole Upto 12 M ) . All Consumable Materials, Ladder, Manpower, Vehicle Required For Maintenance Of Street Pole Light Will Under Scope Of Vendor. , Part - C -Item-67 - Supply & Installation Of Distribution Box :Supply & Installation Of Distribution Box With 63A / 100A Tpmccb, Bakelite Fuse, Bus Bar, Neutral Link In M.S. Sheet Enclosure Of Size Not Less Than 500X750x200mm With Enamel Painting And Cable Entry Holes With Lockable Door. All Mentioned Items Will Be In Scope Of Vendor. , Part - C -Item-68 - Supply, Installation & Commissioning Of Polarization Coupon Along With Magnetic Reed Switch As Per The Scope Of Work , Part - C -Item-69 - Supply Of Solar Charge Contr. 12V / 10A Dc At Sv Stations : Scope Of Work Shall Include Supply And Installation Of Solar Charge Controller For Pole Mounted Solar Light, 12V Dc, 10A ( As Per Installed System ) As Per Direction, Specification & Satisfaction Of Eic , Part - C -Item-70 - Supply Of Solar Charge Contr.Solar Plant: Scope Of Work Shall Include Supply And Installation Of Solar Charge Controller For Solar Plant, 96V Dc / 100A Or 120V Dc / 100A, 48V Dc / 180A ( As Per Installed System ) As Per Direction, Specification & Satisfaction Of Eic. , Part - C -Item-71 - Supply Of Dc / Dc Converter At Rr Station : Scope Of Work Should Include Supply And Installation Of Dc-Dc Converter At Rr / Ip Stations Under Dibiyapur. Input 30 V-70 V. Ouput 48 V , 21A. The Quanity Mentioned Against Each Maintenance Basemay Be Used In Other Region If Required. , Part - C -Item-72 - Permission From Statuary Authority: Scope Of Work Shall Include Granting Permission From Statuary Authority ( Railways / Highway / Forest / Any Government Related Authority ) For Any Kind Of Job In Their Rou Or In Forest Land As Per Requirement Of Gail. Transportation And Other Expenses Involved In The Job Shall Be In The Scope Of Contractor , Part - C -Item-73 - Preventive Maintenance Of Window / Spilt Preventive Maintenance Of Window / Spilit A / C Upto 3 Tons As Per Scope Of Work , Part - C -Item-74 - Preventive Maintenance Of Water Coolers Preventive Maintenance Of Water Coolers Up To 150 Ltrs As Per Scope Of Work , Part - C -Item-75 - Preventive Maintenance Of Refrigerator / D Preventive Maintenance Of Refrigerators / Deep Freezers Upto 350 Ltrs As Per Scope Of Work , Part - C -Item-76 - Sitc Of Starting Capacitor ( 80-100Mfd ) , Part - C -Item-77 - Sitc Of Running Capacitor ( 36 Mfd ) , Part - C -Item-78 - Sitc Of Starting Relay For A / C, Wc, Rg , Part - C -Item-79 - Sitc Of Thermostat , Part - C -Item-80 - Sitc Of Over Load Relay A / C, Wc, Rg , Part - C -Item-81 - Sitc Of Shaft For Blower Motor , Part - C -Item-82 - Sitc Of Bush For Blower Motor , Part - C -Item-83 - Sitc Of Float Valve For Water Cooler , Part - C -Item-84 - Sitc Of Fan Blade For Condenser , Part - C -Item-85 - Sitc Of Selector / Rotary Switch A / C , Part - C -Item-86 - Sitc Of Air Filter For Cooling Coil Of A Sitc Of Air Filter For Cooling Coil Of A / C , Part - C -Item-87 - Sitc Of Blower For A / C , Part - C -Item-88 - Sitc Of The Faulty Compressor Of Window / Split Sitc Of The Faulty Compressor Of Window / Split Ac Upto 3 Ton With New One In Buyback Scheme Of Old Burnet Compressor As Per Scope Of Work And Direction Of Eic , Part - C -Item-89 - Sitc Of The Faulty Compressor Of Refrige Sitc Of The Faulty Compressor Of Refrigerator / Water Cooler Upto 350 Ltr. With New One In Buyback Scheme Of Old Burnet Compressor As Per Scope Of Work And Direction Of Eic , Part - C -Item-90 - Sitc Of The Control Card For Single Ph Sitc Of The Control Card For Single Phase Window / Split Ac As Per Scope Of Work And Direction Of Eic , Part - C -Item-91 - Sitc Of Capillary / Copper Pipe Require Fo Sitc Of Capillary / Copper Pipe Require For Window / Split Ac , Water Cooler Refregerator Application As Per Scope Of Work And Direction Of Eic , Part - C -Item-92 - Supply And Charging Of Refregient Gas To Supply And Charging Of Refregient Gas To The Compressor Of Split / Window Ac / Refregerator / Water Cooler As Per Scope Of Work And Direction Of Eic Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 1.61 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
45.
Petroleum and Natural Gas #4887213 AOC
Bids Are Invited For Custom Bid For Services - Providing Night Patrolling Vehicles Npv Without Driver For 5000 Km Running Per Vehicle Per Month Qty 72 Months , Custom Bid For Services - Extra Running Kms For Npv Over Above 5000 Kms Per Month For Each Vehicle Qty 10800 Kms , Custom Bid For Services - Providing Services For Gps Hand Held Devicesnight Vehicle Devices Including Supply Of New Gps Device As Per Scope Of Work Maintenance Repair Charges Of Devices Maintenance Of Gps Software Sim Card Rental Charges Etc Qty 14.. , Custom Bid For Services - Miscelleneous Fixed And Operating Cost Vbpl Mp Qty 24 Months It Will Include Uniformwinter Clothrain Coatstick Whistle Safety Shoes Id Card Equipment Police Verification Recruitment Hiring Expenses Periodic Health Checkup .. , Custom Bid For Services - Admin Cost Service Charge For First Year Vbpl Madhya Pradesh Do Not Quote Less Tha Two And Half Percent Of Fixed Manpower Cost , Custom Bid For Services - Admin Cost Service Charge For Second Year Vbpl Madhya Pradesh Do Not Quote Less Tha Two And Half Percent Of Fixed Manpower Cost , Custom Bid For Services - Providing Night Patrolling Vehicles Npv Without Driver For 5000 Km Running Per Vehicle Per Month For Rou Night Surveillance Qty 72 Months , Custom Bid For Services - Extra Running Kms For Night Patrolling Vehicle Npv Over Above 5000 Kms Per Month For Each Vehicle For Gujarat Qty 10800 , Custom Bid For Services - Providing Services For Gps Hand Held Devicesnight Vehicle Devices Including Supply Of New Gps Device As Per Scope Of Work Maintenance Repair Charges Of Devices Maintenance Of Gps Software Sim Card Rental Charges Etc Qty 16.. , Custom Bid For Services - Miscelleneous Fixed And Operating Cost It Will Include Uniformwinter Clothrain Coatstick Whistle Safety Shoes Id Card Equipment Police Verification Recruitment Hiring Expenses Periodic Health Checkup Cost Etc Qty 24 Months , Custom Bid For Services - Admin Cost Service Charge For The First Year For Vbpl Gujarat Do Not Quote Less Than Two And Half Percent Of Fixed Manpower Cost , Custom Bid For Services - Admin Cost Service Charge For The Second Year For Vbpl Gujarat Do Not Quote Less Than Two And Half Percent Of Fixed Manpower Cost , Custom Bid For Services - Providing Surveillance Recce Vehicles Srv Without Driver For 2000 Km Running Per Vehicle Per Month For Surveillance And Patrolling As Mentioned In Scope Of Work For Cot Vadinar Qty 24 Months , Custom Bid For Services - Extra Running Kms For Surveillance Recce Vehicles Srv Over Above 2000 Kms Per Month For Each Vehicle For Cot Vadinar Qty 2400 Kms , Custom Bid For Services - Miscelleneous Fixed And Operating Cost Cot Vadinar Qty 24 Months , Custom Bid For Services - Admin Cost Service Charge For The First Year For Cot Vadinar Do Not Quote Less Than Two And Half Percent Of Fixed Manpower Cost , Custom Bid For Services - Admin Cost Service Charge For The Second Year For Cot Vadinar Do Not Quote Less Than Two And Half Percent Of Fixed Manpower Cost
Contract Date: Ref. Documents Contract Value : 3.76 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 79.91 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Contract Date: Ref. Documents Contract Value : 1.19 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
Contract Date: Ref. Documents Contract Value : 18.00 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 83.12 Lakh
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : 59.31 Lakh
Government Departments No of Bidders 4
TenderDetail
Loading tenders