View Bid Results For River Training Tenders

We found 453 Bid Results related to river training tenders. You can find Contractor details who won river training tenders along with contract details in Bid awards announcements section.

Filters
Stage
401
32
20
Tender Publishing Platform
13
440
State / UT
26
227
54
35
22
17
15
14
12
9
8
8
6
4
3
3
2
2
2
2
2
1
1
1
1
1
1
Contract Value
59
93
208
93
Publish Date
0
0
0
0
0
Sector
17
269
49
23
21
19
17
15
11
11
9
3
1
1
1
1
1
1
Ownership
4
411
18
14
10
Within keyword
Active filters:
Showing 1–10 of 453 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 9.23 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 3.49 Lakh
Government Departments No of Bidders 1
Contract Date: Jun 16, 2026 Contract Value : 2.11 Crore
Government Departments No of Bidders 4
Madhya Pradesh View Result →
4.
Drinking Water Supply and Sanitation #11260016 Technical Bid
Tender for Construction Of Kalamba Tank (With Canal) Across Local Nalla Near Village Kalamba Tehsil/Block Pansemal District Barwani (M.P.) To Store 2.07 Mcum Of Water With Designed Area 375 Hectares Comprising Of Preparation Of Construction Drawings & Design, Obtaining Approval Of All Construction Drawings & Design From The Competent Authority Including Construction Of All Civil, Mechanical, And Electrical Works Involved In The Construction Of Dam And Canal. The Work Includes Survey Of Head Work And Canal, Submergence With Fixing Of Chainage Cum Boundary Stone, Geological Investigations, Preparation, And Submission Of Complete Land Acquisition (La) Cases To Competent Authority For Land Acquisition Of Dam Seat And Submergence Area And Perusing La Cases For Award, Forest Clearance, And All Other Clearances Which Are Required For Dams & Canal Construction. All Structures Coming Under Submergence Dam And Canal I.E. Culverts, Bridges, Roads Syphon, Vrb Etc., All Works Including River Training And Construction Of Coffer Dam, Any Other Work As Directed By The Engineer-In-Charge As Per Details Given In Scope Of Work. Area Including Preparation And Submission Of Land Acquisition Cases To Competent Authority For Land Acquisition Of Dam Seat And Submergence Area And Perusing La Cases For Award, Forest Clearance And Any Other Clearance From Competent Authority On Turnkey Basis As Per Detailed Scope Of Work But Not Limited To That.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 16.97 Lakh
Government Departments No of Bidders 1
Contract Date: May 05, 2026 Contract Value : 3.39 Lakh
Government Departments No of Bidders 11
Uttar Pradesh View Result →
Contract Date: May 05, 2026 Contract Value : 3.67 Lakh
Government Departments No of Bidders 10
Uttar Pradesh View Result →
Contract Date: May 05, 2026 Contract Value : 3.42 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Uttar Pradesh View Result →
Contract Date: Mar 27, 2026 Contract Value : 91.31 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
Contract Date: May 01, 2026 Contract Value : 22.39 Lakh
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Arunachal Pradesh View Result →
Contract Date: Jun 05, 2026 Contract Value : 46.69 Lakh
Government Departments No of Bidders 4
23.
Water Resources and Irrigation #10709676 Price Bid
Supply, Installation, Testing, Commissioning Of Adcp ( Range 0.10 To 6.00 Meter ) , Training, Maintenance Etc National Competitive Bidding For Supply, Installation, Testing, Commissioning Of Acoustic Doppler Current Profiler ( Range 0.10 To 6.00 Meter ) With Training, Maintenance And Related Services For Iwrdup Under Nhp For Up ( Sw ) , Acoustic Doppler Current Profiler ( Adcp ) , Supply Of Compact Type Acoustic Doppler Current Profiler ( Adcp ) Having Velocity Profiling Range 0.10 To 6 Meters With Bottom Tracking Facilities, Along With Dgps, Floating Platform ( Small Boat ) And All Associated Peripherals ( Including Batteries, Cables And Carrying Case Etc. ) Along With Laptop With Relevant Software And All Accessories For Discharge Measurement In Rivers / Canals, Open Channels, With Moving Bed Condition, Required Attachments At Site, Complete As Per Technical Specifications. , Acoustic Doppler Current Profiler ( Adcp ) Related Services , Testing And Commissioning Of Compact Type Acoustic Doppler Current Profiler ( Adcp ) Having Velocity Profiling Range 0.10 To 6 Meters With Bottom Tracking Facilities, Along With Dgps, Floating Platform ( Small Boat ) And All Associated Peripherals ( Including Batteries, Cables And Carrying Case Etc. ) Along With Laptop With Relevant Software And All Accessories For Discharge Measurement In Rivers / Canals, Open Channels, With Moving Bed Condition, Required Attachments At Site, Complete As Per Technical Specifications. , Training Of The Purchasers Personnel At The Site In Assembly, Startup & Operation Of Adcp. Which Includes Installation, Testing, Operation At Minimum 3 Different Locations, Retrieval Of Data, Procedure For Generating Rating Curve And Maintenance Requirements & Equipment Configuration, Necessary Training Manuals, Complete As Per Technical Specifications.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
24.
Water Resources and Irrigation #10709673 Price Bid
Supply, Installation, Testing, Commissioning Of Adcp (Range 0.40 To 40.00 Meter), Training, Maintenance And Related Services Supply, Installation, Testing, Commissioning Of Acoustic Doppler Current Profiler (Range 0.40 To 40.00 Meter) With Training, Maintenance And Related Services For Iwrdup Under Nhp For Up(Sw) , Acoustic Doppler Current Profiler (Adcp) , Supply Of Acoustic Doppler Current Profiler (Adcp) Having Velocity Profiling Range 0.40 To 40 Meters With Bottom Tracking And Dgps, Floating Platform (Small Boat) And All Associated Peripherals (Including Batteries, Cables And Carrying Case Etc.) Along With Laptop With Relevant Software And All Accessories For Discharge Measurement In Rivers/Canals, Open Channels, With Moving Bed Condition, Required Attachments At Site, Complete As Per Technical Specifications. , Acoustic Doppler Current Profiler (Adcp) Related Services , Testing And Commissioning Of Acoustic Doppler Current Profiler (Adcp) Having Velocity Profiling Range 0.40 To 40 Meters With Bottom Tracking And Dgps, Floating Platform (Small Boat) And All Associated Peripherals (Including Batteries, Cables And Carrying Case Etc.) Along With Laptop With Relevant Software And All Accessories For Discharge Measurement In Rivers/Canals, Open Channels, With Moving Bed Condition, Required Attachments At Site, Complete As Per Technical Specifications. , Training Of The Purchasers Personnel At The Site In Assembly, Startup & Operation Of Adcp. Which Includes Installation, Testing, Operation At Minimum 3 Different Locations, Retrieval Of Data, Procedure For Generating Rating Curve And Maintenance Requirements & Equipment Configuration, Necessary Training Manuals, Complete As Per Technical Specifications.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
25.
Public Administrative Department #10701374 Price Bid
Re-Tender No.53 Construction Of River Training
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Jammu And Kashmir View Result →
26.
Environment and Forests #10611541 Price Bid
River Training Work
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
31.
Water Resources and Irrigation #10500865 Price Bid
Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Rtdas For Selected Gd Sites Of Investigation And Planning ( Water Resources ) Circle, Meerut, Lucknow And Prayagraj And Integrate With Data Center Located At Lucknow, Up. , Arg +Awlr ( Rtdas ) Atgd Sites Of Investigation And Planning ( Water Resources ) Circle - Meerut, Lucknow And Prayagraj As Per List , Automated Rain Gauge ( Arg ) Sensor With Necessary Hardware As Per Technical Specifications. , Water Levelsensor: Radar Sensor 20 M - Automated Water Level Recorder ( Non-Contact-Radar ) For River, Canals, Reservoir Having 20 Mrange With All Necessary Hardware And Softwareas Per Technical Specifications. , Data Logger 2 Analogue Channels Type With Insat, Gsm & Gprs Based Telemetry Including Antenna And All Necessary Equipment For Data Transmission As Per Technical Specifications. , Solar Panel With All Connectors, Cables And Conduit As Per Technical Specifications. , Battery, Charger Regulator With All Interconnecing Connectors, Cablws For Dcp As Per Technical Specifications. , Nema4x Or Equivalent Enclosure Box To Suit Master Unit Equipment With Locking, Other Ancillary Equipment, Fittings Earthling, Lightening Arrestor With All Connectors, Cables And Conduit For Cables, Mast To Mount Dcp, Sensor Mount Complete As Per Technical Specifications. , Related Services- Arg+Awlr Rtdas At Different Selected Locations Of Gd Sites Of Investigation And Planning ( Water Resources ) Circle, Meerut, Lucknow And Prayagraj As Per List. , Installation Testing & Commissioning Of Automated Rain Gauge ( Arg ) Sensor With Necessary Hardware As Per Technical Specifications. , Installation Testing & Commissioning Of Water Level Sensor: Radar Sensor 20 M - Automated Water Level Recorder ( Non Contact-Radar ) For River, Canal, Reservoir Having 20 M Range With All Necessary Hardware And Software As Per Technical Specifications. , Installation Testing & Commissioning Of Data Logger With 2 Al Channels Type, With Insat, Gsm & Gprs Base Telemetry Including Antenna & All Necessary Equipment For Data Transmission As Per Technical Specifications. , Installation Testing & Commissioning Of Solar Panel With All Connectors, Cables And Conduit As Per Technical Specifications. , Installation Testing & Commissioning Of Battery, Charger Regulator With All Interconnecting Connectors, Cables For Dcp As Per Technical Specifications. , Installation Testing & Commissioning Of Nema4x Or Equvalent Enclosure Box To Suit Master Unit Equipment With Locking, Other Ancillary Equipment, Fittings Earthling, Lightening Arrestor With All Connectors, Cables And Conduit For Cables, Mast To Mount Dcp, Sensor Mount Complete As Per Technical Specifications. , Construction Of Concrete Tower ( 5.5 M Height ) For Installation Of Rtdas Equipment And All Other Accessories As Per Drawing And Technical Specifications. , Integration Of Gsm & Gprs And Satellite Telemetry Data From Entire Rtdas Stations With The Existing State Data Center ( Sdc ) At Lucknow With All Ancillary Equipment As Per Technical Specifications. , Operation & Maintenance During Five Years Comprehensive Warranty Period, For Entire Rtdas With Telemetry System As Specified In Schedule Of Requirement Along With Accessories, Installed At Designated Loations And Data Center Equipment After Final Acceptance Of Rtdas Systems. This Includes Replacement Of Material, Goods & Consumables As & When Required At Bidders Cost Including Cost Of Batteries, The Cost Of Communication For Gsm & Gprs Telemetry For Data Transmission Shall Be Borne By Bidder. The License Fee As Applicable For Dot For Insat Transmission Shall Be Borne By Purchaser. , 3 Days Training Of The Purchasers Personnel At The Suppliers Plant And / Or / Onsie In Assembly, Startup, Operation, Maintenance And / Or Repair Of The Suplied Goods. Course Topics Will Include Sensor Calibration, Data Logger Configuration, Data Downloding, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies As Per Technical Specification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
32.
Housing Urban and Rular Development #10350254 Price Bid
Tender For Supply And Cable And Other Minor Work In Reginal Training Center (Ripa) At Bikaner (Ew) - S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 20 mm 3 Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 4 1.5 sq.mm x 3 core 5 P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 6 50mm x 50mm x 6mm 7 P & Fixing Powder coatedCRCA sheet enclosures on existing angle iron frame by means of nuts and bolts and makingholes , Din rail etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 8 2.0 mm thick 9 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 10 Double pole MCB(With B/C curve tripping Characteristics) 11 6 A to 32 A rating 12 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 13 Electrolytic grade Aluminium bus bar 6010 grade 14 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 4 pole MCCB With Thermal Magnetic release 16 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 17 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 18 6.0 Sq. mm 19 2 core 20 35.0 Sq. mm 21 3.5 core 22 50.0 Sq. mm 23 3.5 core 24 400.0 Sq. mm 25 3.5 core 26 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 27 S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 28 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 29 50 mm 30 110 mm 31 Supply & Laying following size B class ,G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.(Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 32 100 mm dia. 33 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 34 Surface Mounting (with extruded alumn. Housing ) 35 Minimum lumen output 2400 lm 22 W 36 Providing & Fixing of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. surge protection 4 KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 37 Minimum lumen output 1000 lm10W 38 Providing & Fixing of IP - 65 protectedimpact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 x 450x 132 mm 40 Charges for Providing of experienced and Highly skilled/ skilled/semi-skilled/ Un skilledlabour for electric repair/ maintenance/operation of Air conditioning /Air cooling / Fire fighting /Lift/D G set /CCTV/EPABX or any other electromechanical services/ systems as required.( One shift of 8 Hours per day ) 41 Skilled Labour 42 Semi skilled labour 43 Un skilled labour 44 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 45 Single pole MCB (With B/C curve tripping Characteristics) 46 6 A to 32 A rating 47 Four pole MCB (With B/C curve tripping Characteristics) 48 50/63 A rating 49 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 50 Metal door (Three phase) IK-09 and IP-43with Metal end box 51 4 Way 52 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 53 LED Street Light fixture with Minimum lumen output 8700 lm70W 54 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 40 mm Dia. 56 Providing & Fixing of1200 mm sweepBLDC technologypower savingceilingfanwhich can withstand on votage fluctuationsfrom 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10%and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe up to 80 cm, cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 57 Without Remote 58 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 59 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 20W 60 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 61 4 pole MCCB With Thermal Magnetic release 62 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 63 Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 64 17.2 mm thick and 3 Mtr. Long 65 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 66 32mm x6mm G.I. ( Hot Dipped) Strip 67 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 68 10 SWG G.I. ( Hot Dipped) Wire
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
36.
Water Resources and Irrigation #10137387 Price Bid
Annual Repair And Maintenance Of Supplementary Drain. Sub Work:Supply, Installation, Commissioning And Testing Of Equipment Required For Automatic Water Level Station ( Awls ) Radar Type Gprs Telemetry Near Wazirabad Store And D / S Ofrithala Stp Including Construction Of Supporting Structure To Install Radar At Supplementary Drain- Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil. 2 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 3 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . 4 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . 5 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heightsfoundations, Footings, Bases Of Columns, Etc. For Mass Concrete. 6 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights Columns, Pillars, Piers, Abutments, Posts And Struts. 7 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levell.Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 8 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 9 Extra For Laying Stone Work In Or Under Water And / Or Liquid Mud Including Cost Of Pumping Or Bailing Out Water And Removing Slush Etc. Complete. 10 Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete.Hot Finished Seamless Type Tubes. 11 Supplying Hard Stone Of Minimum Size22.50 Cm At Least In Three Direction Including Royalty And Carriage To The Site Of Work With All Lead &Lift Including Loading, Unloading And Stacking At Site Complete. 12 Manufacturing And Supply Ofg.I. Wire Crates Of Size 1M X 1M X 1M Made Out Of G.I. Wire 4 Mm Dia Interwoven And Spaced 15Cm Center To Center Including Cost Of Wire Leads & Lefts Including Carriage To Site Of Work. 13 Manufacturing And Supply Ofg.I. Wire Crates Of Size 2M X 1M X 1M Made Out Of G.I. Wire 4 Mm Dia Interwoven And Spaced 15Cm Center To Center Including Cost Of Wire Leads & Lefts Including Carriage To Site Of Work. 14 Laying And Placing The Stone Filled Wire Crates Of Size 1Mx1mx1m Including All Arrangements For Filling And Placing The Same In Position Including Sealing Of Wire Crates With All Leads & Lifts From Stack To The Site Work ( Exculuding The Cost Of Stone And Wire Crates ) 15 Laying And Placing The Stone Filled Wire Crates Of Size 2Mx1mx1m Including All Arrangements For Filling And Placing The Sme In Position Including Sealing Of Wire Crates With All Leads & Lifts From Stack To The Site Work ( Exculuding The Cost Of Stone And Wire Crates ) 16 Laying Of Stone For Making Apron To The Required Section Including Packing With Smaller At One And In Slopes With All Leads & Lift. 17 Hiring Crane For Providing And Assembling Truss For Water Level Stataion Radar Type With Gprs Telemetry . 18 Care And Diversion Ofstanding Water , Spring Water, River Water Or Drains And The Like In Working Area Including Construction And Removal Of Earth / Coffer Bundies Upto Dbl / Existing Level Where Required Including Pumping And Baling Out Of The Surfaceflowing Water For Keeping The Working Area Free From Standing Water , Flowing Water Seepage Water For Execution Of Entire Work. 19 Supply Of Automated Water Level Recorder ( Non-Contact-Radar ) For River / Canals / Reservoirs Having 15M Range With All Necessary Hardware As Per Technical Specifications. 20 Supply Of Data Logger 8 Analogue Channels Type With Insat, Gsm & Gprs Based Telemetry Including Antenna And All Necessary Equipment For Data Transmission As Per Technical Specifications. 21 Supply Of Solar Panel, Charger Regulator, Batteries Lightening Arrestor With All Connectors, Nema4x Box To Suit Master Unit With Locking, Cables And Conduit For Cables Mast To Mount Dcp As Per Technical Specifications. 22 Installation Testing & Commissioning Of Data Logger With 8 Ai Sensor Input Type, With Insat, Gsm & Gprs Based Telemetry Including Antenna And All Necessary Equipment For Data Transmission As Per Technical Specifications. 23 Installation Testing & Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightning Arrestor With All Connectors, Nema4x Box To Suit Master Unit With Locking, Cables And Conduit For Cables, Associated Civil Works For Mast To Mount Dcp , As Per Technical Specifications. 24 Installation Testing & Commissioning Of Automated Water Level Recorder ( Non-Contact-Radar ) For River / Canals / Reservoirs And Associated Civil Works For Mounting The Radar Having 15M Range With All Necessary Hardware As Per Technical Specifications. 25 Five Year Operation And Maintenance And Comprehensive Warranty For Automated Water Level Recorder ( Awlr ) Radar Type ( 35M ) With Telemetry Along With Accessories , Installed At Designated Locations Under This Contract After Final Acceptance Of Rtdas Systems. This Includes Replacement Of Material And Consumable As And When Required At Bidders Cost. The Cost Of Communications For Gsm And Gprs Telemetry For Data Transmission Shall Be Borne By Bidder. The License Fee As Applicable For Dot For Insat Transmission Shall Be Borne By Purchaser. 26 Server Along With Server Rack, Monitor And 3Kva Online Ups As Per Technical Specifications. 27 It Hardware Which Includes Required Static Ip , Router , Switches , Firewall System And A-3 Size Color Printer As Per Technical Specifications. 28 Three Days Training Of The Purchaser’S Personnel ( 15 Numbers ) At The Supplier’S Plant And / Or / Onsite In Assembly Start-Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Includes Sensor Calibration, Data Logger Configuration Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Processor For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft Andhard Copies As Per Technical Specifications.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
38.
Drinking Water Supply and Sanitation #10082153 Price Bid
Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Rtdas Supplying, Installation, Testing, Commissioning, Operation And Maintenance Of Real Time Data Acquisition System ( Rtdas ) For Selected Barrages, Reservoirs, Rivers / Streams And Canals In A.P , Awlr – Radar Type ( 35M ) Rtdas Station In Ap Region : Price Schedule For Supply Of Goods As Per Schedule Of Requirement : , Automated Water Level Recorder ( Non-Contact-Radar ) For River / Canals / Reservoirs Having 35M Range With All Necessary Hardware And Software As Per Technical Specifications , Data Logger With 2 Ai Channels Type, With Insat, Gsm & Gprs Based Telemetry, Antenna Including All Necessary Equipment For Data Transmission As Per Technical Specifications. , Solar Panel With All Connectors Cables And Conduit As Per Technical Specifications , Battery, Charger Regulator With All Interconnecting Connectors, Cables For Dcp As Per Technical Specifications , Nema4x Or Equivalent Enclosure Box To Suit Master Unit Equipment With Locking, Other Ancillary Equipment, Fittings Earthing, Lightening Arrestor With All Connectors, Cables And Conduit For Cables, Mast To Mount Dcp, Sensor Mount Complete As Per Technical Specifications , Awlr - Radar Type ( 35M ) Rtdas Station In Ap Region Price And Completion Schedule - Related Services , Installation Testing & Commissioning Of Automated Water Level Recorder ( Non-Contact-Radar ) For River / Canals / Reservoirs Having 35M Range With All Necessary Hardware And Software As Per Technical Specifications , Installation Testing & Commissioning Of Data Logger With 2 Ai Channels Type, With Insat, Gsm & Gprs Based Telemetry, Antenna Including All Necessary Equipment For Data Transmission As Per Technical Specifications. , Installation Testing & Commissioning Of Solar Panel With All Connectors Cables And Conduit As Per Technical Specifications , Installation Testing & Commissioning Of Battery, Charger Regulator With All Interconnecting Connectors, Cables For Dcp As Per Technical Specifications , Installation Testing & Commissioning Of Nema4x Or Equivalent Enclosure Box To Suit Master Unit Equipment With Locking, Other Ancillary Equipment, Fittings Earthling, Lightening Arrestor With All Connectors, Cables And Conduit For Cables, Mast To Mount Dcp, Sensor Mount Complete As Per Technical Specifications , Installation Of Chain-Link Fencing Or Cabin Type Structure ( As Per Site Condition ) Along With Lockable Gates As Per Technical Specifications For External Protection Of Sensors And Dcp At Awlr Rtdas Stations As Mentioned In Schedule Of Requirements. , Set Of Data Center Equipment To Collect And Store The Data Received From Proposed Rtdas Established Across The Andhra Pradesh Region At Data Center Located At Vijayawada / Amaravathi , Integration Of Insat, Gsm & Gprs Data With The Existing State Data Centre ( Sdc ) At Vijayawada With All Ancillary Equipment As Per Technical Specifications , Operation & Maintenance During Five Years Comprehensive Warranty Period For Entire Rtdas With Telemetry System As Specified In Schedule Of Requirement Along With Accessories, Installed At Designated Locations Under This Contract And Data Center Equipment Installed Under This Contract After Final Acceptance Of Rtdas Systems.This Includes Replacement Of Material & Consumable As & When Required At Bidders Cost. The Cost Of Communication For Gsm & Gprs Telemetry For Data Transmission Shall Be Borne By Bidder. The License Fee As Applicable For Dot For Insat Transmission Shall Be Borne By Purchaser. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Startup, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Data Logger Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies As Per Technical Specification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Andhra Pradesh View Result →
Contract Date: Apr 07, 2026 Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
West Bengal View Result →
41.
Defence #9930599 AOC
Supply And Construction Of Rtw (River Training Works) And All Items/ Details As Per Technical Specification (Copy Of Rfp Is Att) At Burma, West Bank & Burma Rp Gate To Burma Café In Arunachal Prades- Supply And Fixing Including Labour Stone Boulder Fill In The Gabin Boxes, Stone For The Gabin Facia Shall Hard Angularto Round, Durable And Of Such Quality That They Shall Not Disintegrate On Explosure To Water Or Weathering During The Life Of The Structure. The Min And Max Size Of The Stone Use For Filling Should Be 1.5To 2.5 Times The Mesh Opening. Size Variation May Be Allow 5% Over The Undersize Rock, The Rock Pieces Should Be Properly Hand Packed Min Density Of Stone Is 22 Kn/M3 And Los Angeles Abrassion Value Not More Then 45. Coarse Sand Free From Vegetation Cement 43 Grade Opc Packed In Hdpe Bag Each 50 Kg Wt Conform To Is 8112-1989 (Make: Birla Gold/Ambuja/ Ultratech/Acc/Jk/Dalmia Or Equivalent). Coarse Aggregate 20 Mm Graded Stone For Rr Messonery Less Then 6\ Water Proofing Compound Conform To Is 2645-2003 (Make : Pidilite/ Dr Fixit/ Fevicol Or Equivalent) Quick Setting Compound (Make : Pidilite, Fevicol, Quick Fix Or Equivalent) Supply And Fixing Include Labour The Gabin Boxes Shall Have Haxagonal Woven Mesh With A Maxiumum Size Of 75X75X4Mm Dia , With The Joints Funned By Twisting Each Pair Of Wires Through Three Half Turns. The Diameter Of The Wire Used In The Fabrication Of The Mesh Shall Be 4.0Mm . Sufficient Binding And Tie Wires, Horizontatender For Supply & Construction, Labour And Material Of River Training Wk(Rtw)- L And Vertical Bracers, And Other Acessories Needed For The Assembly An Direction Of The Gabion Works Shall Be Supplied. The Quantity Of Such Wire Shall Be Not Less Than 10% By Weight Of The Gabions Supplied Under The Contract. The Diameter Of The Binding And Connection Wires Shall Be 2.4Mm. The Dimension Of The Gabion Shall Be 1M X 1M X 1M. Weight Of One Gabin Boxes Is Not Less Than 17.00 Kg. These Boxes Are Joined Using Stainless Steel Fasteners Or Lacing Wires Or Galvanized Rings All These Materials Shuld Be Tested And Confirmed To The Spec As Per Is 4826,12753 & Is 4454 (Iv). Hexagonal Woven Mesh Have A Tensile Strength Min 350 N/Mm2- 550 N/Mm2 In Accordance With Is 280. Wire Tolerance Shall Be In Accordance With 16014 (Class T1). Elongation Of Wire Shall Be Not Less Than 10% Min Qty Of Metallic Coating In Accordance With Is 4826 And Zn Al Alloy. Gabin Boxes Should Confirm To Specification As Per Irc : Sp 116-2018. Galvanizing All Wires Used In The Manufacture Of Gabion Boxes And In The Wiring Operations During Construction Shall Be Heavily Coated With Zinc. The Adhesion Of The Zinc Coating To The Wire Shall Be Strong Enough Of An Extent That When The Wire Is Wrapped Six Turns Round A Mandrel Of Four Times Of The Diameter Of The Wire, It Does Not Flake Or Crack To Such An Extent That An Zine Can Be Easily Removed By Rubbing With The Bare Fingers. Selvedges All Edges Of The Gabion Boxes Including End-Panel And Diaphragms Shall Be Mechanically Selvedge In Such A Way To Prevent Unraveling Of The Mesh. The Selvedge Shall Be Of A Wire Having A Diameter Of 4Mm. Fixing After Placing In Position And Before Filling The Gabion Shall Be Stretched To Their Full Size And Shall Be Stretched To Their Full Size And Shall Be Wired To The Adjoining Row At The Top And Bottom Edges And At The Corners. Please Enable Macros To View Boq Information
Contract Date: Apr 20, 2026 Contract Value : 48.84 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Arunachal Pradesh View Result →
42.
Civil Aviation #9912282 AOC
Tender For Har-Ki-Pauri Revitalisation (Haridwar)- 1 Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. 2 Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. 3 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Mortar 1:5 (1 Cement : 5 Coarse Sand), Including Pointing With Cement Mortar 1:2 (1 Cement : 2 Stone Dust) With An Admixture Of Pigment To Match The Shade Of Stone 4 Red Sand Stone 5 Extra For Pre Finished Nosing In Treads Of Steps Of Kota Stone/ Sand Stone Slab. 6 Providing & Laying Of Makrana White Marble Superior Quality Stone Flooring With 40 Mm Thick, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Grey Cement Slurry, Including Rubbing And Polishing Complete. 7 40 Mm Thick Makrana Marble White Superior Quality 8 Providing And Laying 40 Mm Thick Granite Z-Black Superior Quality Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 40 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. 9 40 Mm Thick Granite Z-Black Superior Quality 10 Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: 11 Channels, Angles, Tees And Flats 12 Dismantling Steel Work Manually/ By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Direction Of Engineer-In-Charge 13 Demolishing R.C.C. Work By Mechanical Means And Stockpiling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1 Kilometre, Stacking Serviceable And Unserviceable Material Separately Including Cutting Reinforcement Bars 14 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 15 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 16 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For : 17 Foundations, Footings, Bases For Columns 18 Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purposes Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). 19 Providing And Fixing Isi Marked Ss Tower Bolt (Plate Type) With Necessary Screws Etc. Complete (Copper Oxidised As Per Is 1378): Size 200X10Mm 20 Providing And Fixing Stainless Steel Door Latch With Necessary Screws Etc. Complete :: Size 300X16Mmx5Mm 21 Providing And Fixing Stainless Steel ( Grade 304) 6Mm Dia Solid Chain Made Of Soild Rod Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing & Pcc/Rcc With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Under Of The Floor Or The Side Of Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purposes Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). 22 Drilling Suitable Holes In Reinforced Or Plain Cement Concrete With Power Driven Drill Machine To A Minimum Depth Of 100 Mm Upto 200 Mm In Rcc Beams, Lintels, Columns And Slabs To Introduce Steel Bars For Sunshades/ Balconies Including Fixing The Steel Bars In Position Using Epoxy Resin Anchor Grout Of Approved Make But Excluding The Cost Of Reinforcement, All Complete As Per Direction Of Engineer-In-Charge. 23 Upto And Including 12 Mm Dia. 24 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 25 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived Fromnatural Sources : 3 Graded Stone Aggregate 20 Mm Nominalsize Derived From Natural Sources) 26 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For 27 Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 28 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. 29 Thermo-Mechanically Treated Bars Of Grade Fe-500D Ormore. 30 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 31 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc (Volatile Organic Compound ) Content. 32 With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams/Litre 33 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : 34 New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm) 35 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. 36 All Kinds Of Soil 37 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth,Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth,Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 38 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge, For The Following Grades Of Concrete.: Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 39 All Works Upto Plinth Level 40 Concrete Of M35 Grade With Minimum Cement Content Of 370 Kg /Cum 41 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For 42 Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 43 Suspended Floors, Roofs, Landings, Balconies And Accessplatform 44 Stairs, (Excluding Landings) Except Spiral-Staircases 45 Construction Of Embankment With Material Obtained From Borrow Pits Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300.1 And 300.2 With A Lead Upto 1000 M As Per Technical Specification Clause 301.5 46 For Additional 19 Km Carriage.For Above Item No.3-4 (Mord) 47 Dismantling Of Structures (Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&P And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts And Lead Of 1000 Metres) 48 Steel Work In All Types Of Sections Upto A Height Of 5 M Above Plinth Level Excluding Cutting Of Rivet. Including Dismembering 49 Dismantling Of Structures (Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&P And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts And Lead Of 1000 Metres) 50 Lime /Cement Concrete: By Mechanical Means For Items No. 2.04( B) & ( C): Cement Concrete Grade M-15 & M-20 51 Dismantling Of Structures (Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&P And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts And Lead Of 1000 Metres) Lime /Cement Concrete: By Mechanical Means For Items No. 2.04( B) & ( C): Prestressed / Reinforced Cement Concrete Grade M-20 & Above. 52 Plain Cement Concrete 1:3:6 Nominal Mix In Foundation With Crushed Stone Aggregate 40 Mm Nominal Size Mechanically Mixed, Placed In Foundation And Compacted By Vibration Including Curing For 14 Days. 53 Furnishing And Placing Reinforced/Prestressed Cement Concrete In Super-Structure As Per Drawingand Technical Specification 54 Rcc Grade M25: Using Batching Plant, Transit Mixer And Concrete Pump: For Solid Slab Super-Structure, Height 5M To 10M 55 Supplying, Fitting And Placing Hysd Bar Reinforcement In Super-Structure Complete As Per Drawing And Technical Specifications 56 Providing And Laying 40Mm Sand Blasted (Lakshmi Brown) Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 40 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge : 57 Providing And Laying Sand Blasted (Sera Grey) Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18-20 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge : 58 Providing And Laying Sand Blasted (Steel Grey) Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18-20 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge : 59 52 Mm Thick Cement Concrete Flooring With Concrete Hardener Topping, Under Layer 40 Mm Thick Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) And Top Layer 12 Mm Thick Cement Hardener Consisting Of Mix 1:2 (1 Cement Hardener Mix : 2 Graded Stone Aggregate 6 Mm Nominal Size) By Volume, Hardening Compound Mixed @ 2 Litre Per 50 Kg Of Cement Or As Per Manufacturer’S Specifications. This Includes Cost Of Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 60 Rubbing On Existing Stone Flooring And Filling Of Grooves With Cement Mortar 1:2 (1 Cement : 2 Stone Dust) Admixed With Pigment To Match The Shade Of Stone Etc. Complete In All Respect As Per Direction Of Engineer-In-Charge. 61 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. 62 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 63 Protection To Substructure By Using Coal Tar Epoxy-Providing And Applying Two Coats Of Two Comonent,High Build,100% Solid Content,Low Voc,Polycyclin, Aromatic Hydrocarbon Based,Pot Life2Hrs@72 Degreef,Tack Free-4-6 Hrs,Dft Per Coat 80-120 Microns(Dry) Coal Tar Epoxy Coating With Coal Tar. 64 Finishing Walls With Water Proofing Cement Paint Of Required Shade : 65 New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) 66 Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. 67 In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 68 Finishing With Epoxy Paint (Two Or More Coats) At All Locations Prepared And Applied As Per Manufacturer’S Specifications Excluding Appropriate Priming Coat, Preparation Of Surface, Etc. Complete 69 On Steel Work 70 Extra For Making Chequers Of Approved Pattern On Cement Concrete Floors, Steps, Landings, Pavements Etc. 71 Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. 72 In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete 73 Plastering With Cement Mortar (1:4), 15 Mm Thick On Brickwork In Substructure As Per Technical Specification Clauses 613.4 & 1204 74 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 75 Designing, Enlarging, Supplying, Execution, Transportation, Fixing And Installation Of 2 Panels At Har Ki Pauri, At Haridwarsize: 18Ft X 13Ft = 234 Sftwt: 280 To 300 Kgs Per Panelfasteners: 5’ – 24 To 30 Pcs 76 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work;Using Coarse Aggregate And Fine Aggregate Derived From Naturalsources, Portland Pozzolana / Ordinary Portland /Portland Slagcement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 1.10 Times Of The Specified Minimum Cement Content, The Contractor Shall Havediscretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 77 All Works Above Plinth Level Upto Floor V Level 78 Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum 79 Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 80 Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour : 81 New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than 50 Gram/Litre 82 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : 83 Two Or More Coats Applied On Walls @ 1.25 Ltr/10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr /10 Sqm 84 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-Incharge. 85 Ordinary Rock (5% L.S) 86 Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. 87 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 88 1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 89 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement: 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stoneaggregate 20 Mm Nominal Size Derived From Natural Sources) Over 75Mmthick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation,Levelling & Dressing & Finishing The Top Smooth. 90 Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work;Using Coarse Aggregate And Fine Aggregate Derived From Naturalsources, Portland Pozzolana / Ordinary Portland /Portland Slagcement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete.Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 1.10 Times Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. 91 5.33.1 All Works Upto Plinth Level 92 Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum 93 All Works Above Plinth Level Upto Floor V Level 94 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For 95 Columns, Pillars, Piers, Abutments, Posts And Struts 96 5.30 Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To R.C.C. Projections. 97 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 98 Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 99 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 (1 Cement: 6 Fine Sand) 100 12 Mm Cement Plaster Of Mix : 101 1:6 (1 Cement: 6 Fine Sand) 102 Providing And Fixing Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door/Window/Clerestory Windows & Other Frames/ Chowkhat Comprising Of Virgin Pvc Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/ Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Fabricated With Miter Joints After Applying Pvc Solvent Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg/Cum, Screw Withdrawal Strength Of 2200 N (Face) & 1100 N (Edge), Minimum Compressive Strength Of 58 N/Mm2, Modulus Of Elasticity 900 N/Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixed In Position With M.S Hold Fast/Lugs/Ss Dash Fasteners Of Required Dia And Length Complete As Per Direction Of Engineer-In- Charge. (M.S Hold Fast/Lugs Or Ss Dash Fasteners Shall Be Paid For Separately).Note: For Wpc Solid Door/Window Frames, Minus 5 Mm Tolerance In Dimensions I.E Depth And Width Of Profile Shall Be Acceptable. Variation In Profile Dimensions On Plus Side Shall Be Acceptable But No Extra Payment On This Account Shall Be Made. 103 Frame Size 65 X 125 Mm 104 Providing And Fixing Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Plain Flush Door Shutter Of Required Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade), Calcium Carbonate And Natural Fibers (Wood Powder/ Rice Husk/Wheat Husk) And Non Toxic Additives (Maximum Toxicity Index Of 12 For 100 Gms) Having Minimum Density Of 650 Kg/Cum And Screw Withdrawal Strength Of 1800 N (Face) & 900 N (Edge), Minimum Compressive Strength 50 N/Mm2, Modulus Of Elasticity 850 N/Mm2 And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixing With Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk S.S Screws, All As Per Direction Of Engineer-In- Charge. (Note: Stainless Steel Butt Hinges And Necessary S.S Screws Shall Be Paid Separately) 105 35 Mm Thick 106 Providing And Laying Four Courses Water Proofing Treatment With Bitumen Felt Over Roofs Consisting Of First And Third Courses Of Blown Bitumen 85/25 Or 90/15 Conforming To Is : 702 Applied Hot @ 1.45 Kg Per Square Metre Of Area For Each Course, Second Course Of Roofing Felt Type 3 Grade-I (Hessian Based Self Finished Bitumen Felt) And Fourth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Square Metre, Including Preparation Of Surface But Excluding Grading Complete With : 107 Bitumen Felt (Hessian Base) Type 3 Grade I Conforming To Is : 1322 108 Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) 109 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) 110 Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) 111 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge .(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): 112 With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) 113 Providing And Fixing Brass 100Mm Mortice Latch And Lock With 6 Levers Without Pair Of Handles (Best Make Of Approved Quality) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete. 114 Providing And Fixing Aluminium Round Shape Handle Of Outer Dia 100 Mm With Ss Screws Etc. Complete As Per Direction Of Engineer-Incharge 115 Anodized (Ac 15 ) Aluminium 116 Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Chromium Plated Brass Screws Etc. Complete. 117 50X40X2.5 Mm (Ordinary Type) 118 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 1 0 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete: 119 200X10 Mm 120 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand),Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete 121 Size Of Tile 600X600 Mm 122 Supplying & Erection Of Porta Cabin Consist Of With 1 Room Only Size 3.05M X2.44Mx 2.59M As Per Design, Drawing & Specifications Complete In All Respect And Direction Of Engineer-In-Charge. 123 Supply, Installation, Testing & Commissioning Of Door Metal Detector 16 Zones Size As Per Design/Drawing/Specifications Complete In All Respect And Direction Of Engineer-In-Charge. Etc. Compelte In All Respect And Direction Of Engineer-In-Charge. 124 Supply, Installation, Testing, And Commissioning Drinking Water Atm Reverse Osmos Is (Ro) 100 500 Lph Specifications As Per Manufacture, Etc. Complete In All Respect As Per Direction Of Engineer-In-Charge. 125 Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : 126 Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 127 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) 128 Dismantling Of Structures (Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&P And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts And Lead Of 1000 Metres)By Mechanical Means For Items No. 2.04( B) & ( C): Dismantling Stone Masonry By Manual Means 129 Rubble Stone Masonry In Cement Mortar. 130 Dismantling Of Structures (Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&P And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts And Lead Of 1000 Metres)By Mechanical Means For Items No. 2.04 (Iii) 131 Dismantling Brick / Tile Work/ Rubble Masonary/ Pitching/ Etc By Mechanical Means 132 With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works 133 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : 134 Two Or More Coats On New Work 135 White Washing With Lime To Give An Even Shade : 136 Old Work (Two Or More Coats) 137 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : 138 Old Work (Two Or More Coat Applied @ 1.67 Ltr/ 10 Sqm) On Existing Cement Paint Surface 139 Repair Of Steel Railing To Bring It To Original Shape Cleaning And Repainting As Per Drawing And Technical Specification Clause 1911 140 Portable Barricade In Construction Zone (Installation Of A Steel Portable Barricade With Horizontal Rail 300 Mm Wide, 2.5 M In Length Fitted On A A Frame Made With 45 X 45 X 5 Mm Angle Iron Section, 1.5 M In Height, Horizontal Rail Painted (2 Coats) With Yellow And White Stripes, 150 Mm In Width At An Angle Of 450, A Frame Painted With 2 Coats Of Yellow Paint, Complete As Per Irc:Sp:55-2001 ) 141 Making Sleeves And Cut-Outs In Rcc Walls, Beams And Slabs Of Any Shape And Size By Way Of Core Cutting As Per Requirement Ofarchitectural Instructions Inluding Necessary Tools And Machinaries, Scaffolding, Watering, Rate Also Included Carting Away The Debris From Site Time To Time Or Disposing The Material As Directed And Specified By The Architect / Client Core Cutting Width 400Mm And Depth=300Mm To 600Mm As Per Direction Of Engineer. 142 Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Pvcmedium Well Casing (Cm) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hireand Labour Charges, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Ofengineer -In-Charge. 143 100Mm Diameter 144 200Mm Diameter 145 Constructing Masonry Chamber 30X30X50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I.Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Reinforced Cement Concrete Slab 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand : 3 Gradedstone Aggregate 20 Mm Nominal Size), Including Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stoneaggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design :With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Classdesignation 7.5 146 Constructing Masonry Chamber 60X60X75 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mmdeep ( Inside) With Chained Lid And Rcc Top Slab 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size), Includingnecessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5 147 Constructing Masonry Chamber 120X120X100 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Rcc Top Slab 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size), Including Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : 148 Demolishing R.C.C. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. 149 Supplying ,Installation , Testing , Commissioning Of Vertical Position Submersible Sewage Dewatering Unclog Pump Set For Capacity 05 Hp / 1450 Rpm , Ac 3 Ph , 440V , 50 Hz Having 100 Mm Delivery , Head 12 Meter , Discharge 500 Lpm With Cutter Plate , Sewage / Solid Handling Capacity Size 40 Mm Along With Control Panel ,15 Meter 100 Mm Pvc Hose , C.I. Bends And 15 Meter Submersible Cable Etc. 150 Supplying And Installing Pressure Gauge Of 100 Mm Ø., 0-300 Psi Or 0-21 Kg Per Cm Square Fitted With 12/15 Mm Ø. Pad Cock Valve, And G.I. Pipe, Elbow Etc. As Per Requirement In Approved Manner. 151 Supply, Erection, Jointing, Testing & Commissioning Of \C\ Class Ms Pipes (As Per Is: 1239) Including Necessary Specials Such As Tees, Bends, Flanges Reducers Etc., Complete On Wall/ Ceiling. The Pipes To Be Erected On Wall Or Suspended From Beams, Rcc Roof Slabs With Suitable Size Ms Bars/ Angle Irons Including Painting Of Metal Part Except Pipe Line. 152 80Mm Dia. 153 100Mm Dia. 154 Painting (Two Or More Coats) On Rain Water, Soil Waste And Vent Pipes And Fittings With Aluminium Paint Of Approved Brand And Manufacture Over A Priming Coat Of Ready Mixed Zinc Chromate Yellow Primer On New Work : 155 75 Mm Diameter Pipes 156 100 Mm Diameter Pipes 157 Providing And Fixing C.I. Sluice Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertions Etc. (The Tail Pieces If Required Will Be Paid Separately) : 158 Sluice Valve/Scour Valve 159 100 Mm Dia. Pn-1.6. 160 Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 161 80 Mm Dia. (Class -Pn 1.0 Rating) Flanged Type 162 Providing & Fixing Following Cast Iron Double Acting Air Valves, Flanged Without Inbuilti Solating Valve As Per Is : 14845-2000 Including Jointing &Testing With Cost Of Jointing Material And Rubber Insertion All Complete Asper Is :13095-1991 163 80 Mm Dia Pn-1.6 164 Providing, Laying, Jointing, Testing And Commissioning Of Brass/ Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) All Complete As Per Technical Specifications And As Per Direction Of Engineer. 165 32 Mm Nominal Bore 166 Excavation For Structures (Earth Work In Excavation Of Foundation Of Structures As Per Drawing And Technical Specification, Including Setting Out, Construction Of Shoring And Bracing, Removal Of Stumps And Other Deleterious Matter, Dressing Of Sides And Bottom, Backfilling The Excavation Earth To The Extent Required And Utilising The Remaining Earth Locally For Road Work.) 167 Ordinary Rock (Not Requiring Blasting) Upto 3 M Depth. Mechanical Means 168 Plain/Reinforced Cement Concrete In Sub-Structure Complete As Per Drawing And Technical Specifications 169 Rcc Grade M35 170 Height Upto 5M With Batching Plant, Transit Mixer And Concrete Pump 171 Supplying, Fitting And Placing Un-Coated Hysd Bar Reinforcement In Foundation Complete As Per Drawing And Technical Specifications 172 Filler Joint: Providing & Fixing 20 Mm Thick Compressible Fibre Board In Expansion Joint Complete As Per Drawing & Technical Specification 173 Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigmentmatching The Stone Shade : (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) : 174 Red Sand Stone - Exposed Face Machine Cut And Table Rubbed With Rough Backing.40 Mm Thick 175 Construction Of Rock Fill Embankment With All Lifts And Lead Upto 5 Km- Construction Of Rock Fill Embankment From Roadway Excavation With Broken Hard Rock Fragments Of Size Not Exceeding 300 Mm Laid In Layers Not Exceeding 500 Mm Thick Including Filling Of Surface Voids With Stone Spalls, Blinding Top Layer With Granular Material, Rolled With Vibratory Road Roller, All Complete As Per Clause 313 176 Supplying, Fitting And Placing Un-Coated Hysd Bar Reinforcement In Foundation Complete As Per Drawing And Technical Specifications. 177 Supplying, Fitting And Placing Hysd Bar Reinforcement In Sub-Structure Complete As Per Drawing And Technical Specifications 178 Plain/Reinforced Cement Concrete In Open Foundation Complete As Per Drawing And Technical Specifications 179 Pcc Grade M15 180 With Batching Plant, Transit Mixer And Concrete Pump 181 Providing Weep Holes In Brick Masonry/Plain/Reinforced Concrete Abutment, Wing Wall/Return Wall With 100 Mm Dia Ac Pipe, Extending Through The Full Width Of The Structure With Slope Of 1V :20H Towards Drawing Foce. Complete As Per Drawing And Technical Specifications 182 Providing And Laying Of Filter Media With Granular Materials/Stone Crushed Aggregates Satisfying The Requirements Laid Down In Clause 2504.2.2. Of Morth Specifications To A Thickness Of Not Less Than 600 Mm With Smaller Size Towards The Soil And Bigger Size Towards The Wall And Provided Over The Entire Surface Behind Abutment, Wing Wall And Return Wall To The Full Height Compacted To A Firm Condition Complete As Per Drawing And Technical Specification. 183 Gabian Structure For Erosion Control, River Training Works And Protection Works (Providing And Constructing Gabain Structures For Erosion Control, River Training Works And Protection Works With Wire Crates Of Size 2 M X 1 M X 0.3 M Each Divided Into 1M Compartments By Cross Netting, Made From 4 Mm Galvanised Steel Wire @ 32 Kg Per 10 Sqm Having Minimum Tensile Strength Of 300 Mpa Conforming To Is:280 And Galvanizing Coating Conforming To Is:4826, Woven Into Mesh With Double Twist, Mesh Size Not Exceeding 100 Mm X 100 Mm, Filled With Boulders With Least Dimension Of 200 Mm, All Loose Ends To Besecurely Tied With 4 Mm Galvanised Steel Wire.) 184 Providing And Laying Pitching On Slopes Laid Over Prepared Filter Media Including Boulder Apron Laid Dry In Front Of Toe Of Embankment Complete As Per Drawing And Technical Specifications 185 Stone/Boulder 186 Geotextile Filter (Laying Of A Geotextile Filter Between Pitching And Embankment Slopes On Which Pitching Is Laid To Prevent Escape Of The Embankment Material Through The Voids Of The Stone Pitching/Cement Concrete Blocks As Well As To Allow Free Movement Of Water Without Creating Any Uplift Head On The Pitching.) 187 Sitc Of 20W Multi Color Spot Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Wall Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 20W, Cct : Rgbw, (As Per The Design Approval) Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik05, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik05, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length >400Mm. 188 Sitc Of High Quality Long Through Multi Color Wash Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights Having The Rotation Degrees Embosed In The Die Cast. Power Consumption : 50W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik08, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length >300Mm. 189 Sitc Of High Quality Long Through Multi Color Wash Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights Having The Rotation Degrees Embosed In The Die Cast. Power Consumption : 150W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik08, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length >300Mm. 190 Sitc Of High Quality Multi Color Neon Flexible Light, Protection Rating : Ip67, Mounting Structure : Adjustable Wall Mount Ss Clips For Fixing The Lights. Power Consumption : 12W, Cct : Rgb/Rgbw, (As Per The Design Approval) Beam Angle : 120º, Control : Dmx512 Channel : 4 Ch, Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Time Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Epistar, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. 191 Sitc Of Aluminium Profile For Neon Flex 192 Sitc Of Porta Cabin Ms Structure Base Frame \C Channel Of Size 50X100X50Mm With Ms Tubular Pipe Of 75X40Mm,50X50Mm & 25X 25Mm Interconnecting Ms Pipes 6 Raised Legs Of Size100X100Mm Corner Of Size 75X75Mm. Ms Cabin Rpcc Make Manufactured Using 19 Gauge With Inner Layer Of Action Teasa Laminated Mdf Board 6Mm Thick & Insulation Of Glass Wool. The Cabin Will Be Duly Painted Outside And Inside. These Are A Water Proof, Termite; Heat And Fire Resistant And Comfortable In Extreme Hot Or Cold Climate With Lifting & Shifting Arrangement. Window Size 3X3 Aluminum Bombay Sliding Glass Window With Ms Grill & Locking Arrangements & Rain Shed, Internal Wall Paneling Will Be Done By 6Mm Laminated Board, False Ceilling Will Be Done 6 Mm Laminated Board In Wooden Finish With Glass Wool Of Density 36Kg/M3. Flooring Will Be Done By 18Mm Cement Fiber Board With Lh Vinyl Flooring. Ms Door For Main Entrance With Locking Arrangement (Eldrop Only) All Electrical Fittings Of (Ancor/ Havells) Make Including Pvc Pipe With Internal Wiring (Ancor/ Havells) External Wiring Is Out Of Our Scope 1 Nos.Bulkhead Light (Outside), 4 No. Light Point, 4 No. Fan Point, 4 Nos. 6 Amp Switch & Socket (Extra), 1 No.32 Amp Mcb Box, 1 No. 16 Amp Ac Point Paint Will Be Done By Outside Enamel Paint Of Desired Color.Split Type Airconditioner 1.5 Ton, 3 Star Bee, Inverter Technology With Stablizer. 193 Sitc Of High Quality Long Through Multi Color Linear Wash Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 80W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik07, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length >300Mm. 194 Sitc Of High Quality Long Through Multi Color Linear Wash Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 50W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik07, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length >300Mm. 195 Sitc Of High Quality Long Through Multi Color Linear Wash Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 30W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik07, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Moulded Connector Having The Length >300Mm. 196 Sitc Of Dc Power Driver For The Above Lights, Power : 200W, Input : Ac 110-240V Ac, 50Hz, Output : Dc 12/24V, Protection Rating, Ip67, Surge Protection : Ll 4Kv, Le 6Kv 197 Sitc Of High Quality Dmx Decoder, Power Input : Dc 24V, 198 Sitc Of Ip Driver Box Made Up Of Pvc / Upvc For The Internal Terminations And External Outgoing Connecting Points, With Required Pvc / Brass Glands, Optional Suitable Size Mcb Fitted For Control Outgoing Circuits. 199 Sitc Of Pvc Insulated Multi Core Electrical Un Armored Flexible 5C X 0.5Sq Mm Power Cable Having Less Electrical Losses. (As Per Actuals Depending Upon The Site Condition) 200 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/Recessed Steel/ Pvc Conduit As Required 201 3C X 1.5 Sq.Mm 202 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/Recessed Steel/ Pvc Conduit As Required 203 3C X 2.5 Sq.Mm 204 Sitc Of 5 Core Dmx Cable Comprises Twisted Pairs With Shield Support For Carrying Of Data. Dmx512 Cable Is Used For Connecting All Light Consoles That Use Dmx 512 Standard Data Transmission. (As Per Actuals Depending Upon The Site Condition) 205 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 206 4C X 25 Sq.Mm 207 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With Allaccessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Iicomplete With Fitting And Cutting, Jointing Etc. In The Existing Trench, Complete As Required 208 90Mm Dia ( Od -90Mm & Id 76Mm Nominal ) 209 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along Withaccessories In Surface/Recess Including Cutting The Wall And Making Good Thesame In Case Of Recessed Conduit As Required 210 25Mmdia 211 Sitc Of Ip65 \I\ Power Connectors Having 3/4 Pole Cable Connector, Chuck Type Strain Relief, Current Rating 20 A Rms Continuous, Easy And Extremely Precise Locking System \Quick Lock\ High Impact Materials - Long-Lasting And Reliable 212 Sitc Of Ip65 \I\ Dmx Connectors Having 3/5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, \Solder Stop\ For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. 213 Sitc Of Dmx Signal Amplifier For Improving/Amplifying The Input Signals Through Longer Distances. 214 Sitc Of Dmx Isolator Or Splitter Provides Isolated Optical Dmx Splitter Provides 8 Outputs From A 1 Input And Input Voltage: Ac 110 To 220 V, 50 Hz, Product Features: Group 1 & Group 8 Dmx Signal Change. 215 Sitc Of 5 Pin Xlr Male Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, \Solder Stop\ For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. 216 Sitc Of Power Main Distribution Board Made Up Of Ms Sheet Metal Fabricated Housing Black Powder Coated And Ivery Connectors For The Internal Terminations And External Outgoing Connecting Points, Fibre / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. Timer With Required Contactor For Auto Switching. Power Panel Suitable For Indoor/Outdoor Applicable And Floor Mount / Wall Mount Options.- 8 Nos Of 32A Tpn Mcb Outgoing McbS.- 1No Of 100A Tpn Incoming Mcb. 217 Sitc Of Sub Power Distribution Board Made Up Of Ms Sheet Metal Fabricated Housing Black Powder Coated And Ivery Connectors For The Internal Terminations And External Outgoing Connecting Points, Fibre / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. Timer With Required Contactor For Auto Switching. Power Panel Suitable For Indoor/Outdoor Applicable And Floor Mount / Wall Mount Options.- 12 Nos Of 6/10A Sp Outgoing McbS.- 1No Of 32A Tpn Incoming Mcb. 218 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Lockingarrangement And Watering Pipe Of 2.7 Metre Long Etc. (But Without Charcoal/Coke And Salt) As Required 219 Sitc Of Din Rail Mount Dmx Controller Can Be Used To Control A Wide Variety Of Different Dmx Systems- From Rgb/Rgbw To More Advanced Moving And Color Mixing Luminaires, Dmx Audio Players And Fountains. The Controller Comes With A Variety Of Features, Iphone/Ipad/Android Remote Control, Wi-Fi Facilities, Dry Contact Port Triggering And Flash Memory.Usb Connection • 1024 Dmx Channels Universe In Live Mode (Computer) • 8 Dry Contact Trigger Ports Via He10 Connector • Stand Alone Mode With 5 Area And 90+ Scenes, Mac Osx 10.6/10.7/10.8 - Windows Xp/Vista/Seven/8 32/64 Bits And Usb 2.0, Xlr3, Mini Usb, 1 He10, Power From 5V To 5.5V Dc (Ac/Dc Adapter In Option. 220 Earth Excavation Work For Cable Laying. 221 Sitc Of Programming Charges 222 Sitc Of Supplying And Erecting Iron Work, Sheet Metal Work Consisting Of Crca Sheets, Various Sections Of Iron, Plates, Chequered Plates, Rods, Bars, Ms Pipes, Etc. For Panel Board Or Any Other Purpose With Bending, Cutting, Drilling And Welding Complete Erected At The Position With Necessary Materials Duly Painted With One Coat Of Red Oxide And Two Coats Of Enamel Paint To Match The Switchgears. 223 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 224 1:3:6 (1 Cement : 3 Coarse Sand (Zone-Iii) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominalsize Derived From Natural Sources) 225 Sitc Of 9W Mono Color Spot Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Wall Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 09W, Cct : 1800/3000/4000/6000K, (As Per The Design Approval) Optics : Pmma With Holder, Beam Angle : 15º/25º/45º/60º, Control : On/Off, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Ac 110-230V, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik05, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, Led Life Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik05, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. 226 Sitc Of 12W Multi Color Spot Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Wall Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 12W, Cct : Rgbw, (As Per The Design Approval) Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik05, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik05, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length >400Mm. 227 Sitc Of 17W Mono Color Projector Spot Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Wall Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 17W, Cct : 1800/3000/4000/6000K, (As Per The Design Approval) Optics : Pmma With Holder, Beam Angle : 15º/25º/45º/60º, Control : On/Off, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Dc 24V(External Driver) Or Ac 110-230V, 50Hz. Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Glare : Specially Designed Glare Free Round Shape 360 Deg / 3 Unit. Focussing Area/Led Will Be Kept 90 Deg Perpendicular Below The Glare Free Optic. Size Of The Led Optic & Glare Unit Must Be Equal Or +/-2% Higher To Achieve The Maximum Intensity And Less Glare. This Additional Arrangement Can Be Fixed Or Removed On The Application. Glare Free Optical Design For Human Viewing Angle From A Distance Within 2-3 Mtr. Toughened Transparent Glass Having The Ik Protection Up To Ik05 Sealed Above The Glare Free Unit. Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik05, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. 228 Sitc Of High Quality Long Through Multi Color Wash Light, Protection Rating : Ip66, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights Having The Rotation Degrees Embosed In The Die Cast. Power Consumption : 100W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik08, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length >300Mm. 229 Sitc Of High Quality Multi Color Linear Profile Light, Protection Rating : Ip65, Complying To Bis Standard \Is 10322 (Part 5/Sec 1): 2012\ And Having Ce Certification Against Standard \Low Voltage Directive & Protective Equipment - En 60598-1:2015\, And \Electromagnetic Compatibility Directive - En 61547: 2009\, Mounting Structure : Adjustable Wall Mount Ss Clips For Fixing The Lights. Power Consumption : 15W, Dimension :23Mm, Cct : Rgbw, (As Per The Design Approval) Beam Angle : 120º, Control : Dmx512 Channel : 4 Ch, Body : Extruded Aluminium With Milkwhite Diffuser, Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Time Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Lm79, Ip65, From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Epistar, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Connector Having The Length >100Mm. 230 Sitc Of Gi Cage For Light Protection, Gi Cage Made Of Mesh With Back Openable Door And Suitable Hinges, Light Fixing Provision With Bolting Option, Base Concrete Foundation. 231 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 232 4C X 16 Sq.Mm 233 Sitc Of Factory Fabricated And Wired Metal Clad Dust And Vermin Proof Floor Mounting Panel Tpn Switchboard Complete. The Instrument Chamber Shall Be Separate And Shall Comprise A Multifunction Meter And Current Transformer Etc. The Board Shall Have Suitable Capacity Electrolytic Aluminum Bus Bars As Per Is:8623 Insulated With Heat Shrink Sleeving And Mounted On Non-Hygroscopic Supports Such As Cmc /Dmc Supports With Detachable Side Covers And Shall Be Suitable For An Extension On The Sides. The Switches Shall Be Complete With Cable And Boxes, Pedestal-Type Cable Socket Compression Glands And Indicating Lamps On Incoming Etc. The Power Panel Shall Be Fabricated With Crca Sheet With A Minimum Thickness Of 1.6Mm/2Mm With The Following Incoming And Outgoings Incoming Mccb-150Amp Tpn-01 Multifunction Meter-01 Ryb Indicators-01Set, Outgoing 63 Amp Tpn Mcb- 04 No, 10Amp Sp Mcb - 6Nos. 234 Sitc Of Sub Power Distribution Board Made Up Of Ms Sheet Metal Fabricated Housing Black Powder Coated And Ivery Connectors For The Internal Terminations And External Outgoing Connecting Points, Fibre / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. Timer With Required Contactor For Auto Switching. Power Panel Suitable For Indoor/Outdoor Applicable And Floor Mount / Wall Mount Options.- 22 Nos Of 6/10A Sp Outgoing McbS. - 1No Of 63A Tpn Incoming Mcb. 235 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. (But Without Charcoal/ Coke And Salt) As Required. 236 Sitc Of Din Rail Mount Dmx Controller Can Be Used To Control A Wide Variety Of Different Dmx Systems- From Rgb/Rgbw To More Advanced Moving And Color Mixing Luminaires, Dmx Audio Players And Fountains. The Controller Comes With A Variety Of Features, Iphone/Ipad/Android Remote Control, Wi-Fi Facilities, Dry Contact Port Triggering And Flash Memory. Usb Connection • 2048 Dmx Channels Universe In Live Mode (Computer) • 8 Dry Contact Trigger Ports Via He10 Connector • Stand Alone Mode With 5 Area And 90+ Scenes, Mac Osx 10.6/10.7/10.8 - Windows Xp/Vista/Seven/8 32/64 Bits And Usb 2.0, Xlr3, Mini Usb, 1 He10, Power From 5V To 5.5V Dc (Ac/Dc Adapter In Option. 237 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/Recessed Steel/ Pvc Conduit As Required 238 3C X 1.5 Sq.Mm 239 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 240 4C X 16 Sq.Mm 241 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Lockingarrangement And Watering Pipe Of 2.7 Metre Long Etc. (But Without Charcoal/Coke And Salt) As Required 242 Sitc Of Programming Charges 243 Supply, Installation, Testing & Commissioning Of - Double Arm7000Mm Pole Made Of Circular Mild Steel Pipe Of Two Section (Grade Yst 210), Bottom Section 139.7Mm Dia X 3.6Mm Thick With 1607Mm Height & Top Section 114.3Mm Dia X 3.2Mm Thick With 1858Mm Height. Decorative Base Made Of Gravity Die-Cast Aluminium (504Mm Dia X 1324Mm Height). Decorative Die Cast Aluminium Cone (230Mm Dia X 150Mm Height) Covered On The Both Section Joint Area. The Double Arm Pelican Orna Eva Bracket Is A Split Constructed Type, Bracket Stem Made Of Ms Pipe 60.3Mm Dia X 2.6Mm Thick, Emerging From A Split Collar Upto A Height 1379Mm Crowned At The Top With A Decorative Eva Made Of Gravity Die Cast Aluminium In Single Piece Of 682Mm Height. The Artistically Curved Double Arm Made Of Ms Pipe 38.1Mm X 2Mm Thick, Spruced Up With Ms Scroll With Gravity Die Cast Aluminium Leaf And Ms Floral Embellishment, Is Firmly Held To The Stem By Way Of Cast Iron Clamps And The Arm Bears Cast Iron Knobs At One End And Other End Facilitates The Fitment Of Pendant Luminaire At 890Mm On Either Sides From The Vertical Axis Of The Bracket Stem. Pole Section Welded By Certified Welders Using High End Mig Welding Processes. Pdc Aluminium Service Door 348Mm Height X 110Mm Width Shall Be Provided With The Company Logo Embossed On The Bottom Of The Door And Safety Rope. The Control Gear Tray Is Prewired With 2.5 Sq.Mm Cable, 6A Sp Mcb And 32A Ramanuj Stud Type 4 Way Terminal Block For Loop-In / Loop-Out Arrangement, 5A 2 Way Terminal Connector And Provision For Earthing. Any Other Internal Cables And Connections Shall Not Be Covered In The Scope Of Supply. Mild Steel Mounting Plate 300Mm Square X 16Mm Thick Steel Of Grade E250 To Is 2062 : 2011 With 4 Elongated Holes 48 X 24 To Suit M20 X 500Mm Bolts Of Grade 4.6 At Cc 215. The Base Plate Have A Cable Entry Hole As Per The Base Pipe Size. This Mounting Steel Plate Along With Foundation Bolts Of Suitable Size To Be Used For Ensuring Firm Grouting Into The Specially Designed Foundation. All Dimension Are Within +/- 5% Tolerance. The Pole Is Coated With Zinc Rich Primer & Pure Polyester Powder Coating Or Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint (Coating Thickness 60- 80 Microns). The Pole Shall Be Provided With Graphite Grey / Anthracite Grey / Black As Standard Colour Options. 244 Supply, Installation, Testing & Commissioning Of Input Power : 90W Ledtechnical Description Pendant Mounted Compact Street Light. Type Iv (Asymmetrical Light Distribution). Luminaire Made Of Specially Contoured Spun Aluminium Body Of High Corrosion Resistance With A Neck Design For Unique And Better Aesthetics And Non Corrosive Stainless Steel Fasteners. Clear Acrylic / Clear Polycarbonate Diffuser. The Luminaire Have Extruded Aluminium Heatsink For Thermal Management With Vertical Fin Design For Longer Life Of The Leds. The Mounting Arrangement Nipple, Coupling & Hex Nut Made Of Stainless Steel 304 Suitable For Mounting To Internally Threaded Pipe Of Designation M30. Protection Class Ip65. Mechanical Resistance Ik05 (Acrylic Diffuser) & Ik09 (Polycarbonate Diffuser). Pure Polyester Powder Coated Graphite Grey / Anthracite Grey / Jet Black. Available Colour Temperature 3000K / 4000K / 5700K, Colour Rendering Index (Cri)>70. K-Lite Led Module With Expected Service Life Of At Least 72,000 Operating Hours. Prewired With Led Driver And Suitable For Operating On 240V, 50Hz Single Phase Ac Supply. Driver Efficiency >85%, Power Factor >0.95, Thd 245 Supply, Installation, Testing & Commissioning Of - Single Arm7000Mm Pole Made Of Circular Mild Steel Pipe Of Two Section (Grade Yst 210), Bottom Section 139.7Mm Dia X 3.6Mm Thick With 1607Mm Height & Top Section 114.3Mm Dia X 3.2Mm Thick With 1858Mm Height. Decorative Base Made Of Gravity Die-Cast Aluminium (504Mm Dia X 1324Mm Height). Decorative Die Cast Aluminium Cone (230Mm Dia X 150Mm Height) Covered On The Both Section Joint Area. The Single Arm Pelican Orna Eva Bracket Is A Split Constructed Type, Bracket Stem Made Of Ms Pipe 60.3Mm Dia X2.6Mm Thick, Emerging From A Split Collar Upto A Height 1379Mm Crowned At The Top With A Decorative Eva Made Of Gravity Die Cast Aluminium In Single Piece Of 682Mm Height. The Artistically Curved Single Arm Made Of Ms Pipe 38.1Mm X 2Mm Thick, Spruced Up With Ms Scroll With Gravity Die Cast Aluminium Leaf And Ms Floral Embellishment, Is Firmly Held To The Stem By Way Of Cast Iron Clamps And The Arm Bears Cast Iron Knobs At One End And Other End Facilitates The Fitment Of Pendant Luminaire At 890Mm From The Vertical Axis Of The Bracket Stem. Pole Section Welded By Certified Welders Using High End Mig Welding Processes. Pdc Aluminium Service Door 348Mm Height X 110Mm Width Shall Be Provided With The Company Logo Embossed On The Bottom Of The Door And Safety Rope. The Control Gear Tray Is Prewired With 2.5 Sq.Mm Cable, 6A Sp Mcb And 32A Ramanuj Stud Type 4 Way Terminal Block For Loop-In / Loop-Out Arrangement, 5A 2 Way Terminal Connector And Provision For Earthing. Any Other Internal Cables And Connections Shall Not Be Covered In The Scope Of Supply. Mild Steel Mounting Plate 300Mm Square X 16Mm Thick Steel Of Grade E250 To Is 2062 : 2011 With 4 Elongated Holes 48 X 24 To Suit M20 X 500Mm Bolts Of Grade 4.6 At Cc 215. The Base Plate Have A Cable Entry Hole As Per The Base Pipe Size. This Mounting Steel Plate Along With Foundation Bolts Of Suitable Size To Be Used For Ensuring Firm Grouting Into The Specially Designed Foundation. All Dimension Are Within +/- 5% Tolerance. The Pole Is Coated With Zinc Rich Primer & Pure Polyester Powder Coating Or Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint (Coating Thickness 60-80 Microns). The Pole Shall Be Provided With Graphite Grey / Anthracite Grey / Black As Standard Colour Options. 246 Supply & Installation Of 3Phase ,15Kva Outdoor Type Ccms Panel Equipped With 1 No Street Light Controller, 1 No Energy Meter,1 No Tpn Mcb, 3 Nos 3 Pole Contactors, 3 Nos 1Pole Mcb’S, Battery, Smps, 3 Nos Current Transformers & Toggle Switches 247 Supplying And Fixing Of Sheet Steel Enclosure On Surface/Recessalong With 25Amps,Double Pole ,240V,10Ka, C Curve Mcb Complete With Connections Testing & Commissioning As Required 248 Supply Of 2C X 4Sqmm Copper Armoured Cable 249 Laying Of 2Cx4Sqmm Copper Armoured Cable 250 Aluminium Armoured Cable 251 4 X 16 Sq. Mm Aluminium Armoured Cable 252 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 253 Providing, Laying And 80 Mm Dia G.I. Pipe (Medium Class) In Ground Complete With G.I. Fittings Including Trenching (75 Cm Deep)And Re-Filling Etc As Required. Dsr No 254 Supply & ;Laying Of 63Mm Dia Dwc Hdpe Pipe Isis Marked Along With All Accessories Like Socket,Bend,Couplers Etc.Conorming To Is 14930 Part Ii Complete With Fitting And Cutting ,Joining,Etc.Direct In Gorund (75Cm Below Ground Leve;) Inclsuing Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc,Complete As Required. 255 Supplying And Making End Termination With Brass Compression Gland And Aluminum Lugs For Following Size Armoured Aluminum Conductor Power Cable Of 1.1 Kv Grade As Per Specification. . 256 4 X 10 Sq. Mm (25 Mm) 257 4 X 16 Sq. Mm (28 Mm) 258 Supplying And Making Straight Through Joint With Heat Shrinkable Joint Kit Including Aluminium Ferrules For Following Size Of Frls Pvc Insulated And Pvc Sheathed / Xlpe Aluminum Conductor Cable Of 1.1 Kv Grade As Per Specification. . 259 4 X 16 Sq. Mm 260 Mdb -1 ( Near Ccr Building ) 261 Sitc Of Wall/Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel For Electrical Works, Made Out Of Crca Sheet. Other Parameters Required As Per Point (A) Thickness Of Sheet Shall Not Be Less Than 1.6 Mm Up To 600 Mm Length/Width Of Any Compartment And Be Of 2.0 Mm Above 600 Mm. Load Bearing Structure Shall Be Of 2.0 Mm Thick Sheet Supported By Base M.S. Channel If Required. Side Walls And Cable Alley Compartment Shaving Bolted Type Doors With/Without Detachable Extension Type Structure (B) Panel Shall Be Duly Treated For Derusting In 7 Tank Process With De Phosphating And With Powder Coating Of Minimum 70 Microns On Both Side Of Panel In Desired Shade The Panel Having Pu/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness, Required Hardware, Separate Detachable Gland Plate M.S. Base Channel (Min 75Mm), Hinged Door With Locking Arrangement For Equipment/Switchgear (C) Interconnection Between Bus Bar And Switch Gears/Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Upto 125 Amp) And By Solid Bus Bar(>125 Amp). 262 Incomer 263 4P Mccb, 200A As Out Going 36Ka 264 Metering & Indication 265 1 Set Of Phase Indicating Lamps (Red/Yellow/Blue) 266 200/5A Ct 267 0-200 Amps Ammeter Analog 268 0-500 Amps Voltmter Analog 269 Selector Switch For Voltmeter 270 Selector Switch For Ammeter 271 Bus-Bar 272 1 Set Of 200A 4P Aluminium Bus Bar With Colour Coded Pvc Sleeves (4X800Mm)
Contract Date: May 30, 2026 Contract Value : 57.09 Crore
Government Departments No of Bidders 3
Uttarakhand View Result →
Contract Date: Mar 25, 2026 Contract Value : 5.96 Crore
Government Departments No of Bidders 8
Maharashtra View Result →
TenderDetail
Loading tenders