View Bid Results For Refrigerant Gas Tenders

We found 1818 Bid Results related to refrigerant gas tenders. You can find Contractor details who won refrigerant gas tenders along with contract details in Bid awards announcements section.

Filters
Stage
1638
97
83
Tender Publishing Platform
1013
805
State / UT
34
201
186
185
131
126
109
83
80
79
75
74
72
65
56
53
51
28
27
22
22
18
14
11
11
10
9
7
5
2
2
1
1
1
1
Contract Value
482
703
549
81
Publish Date
7
1
0
0
0
Sector
31
499
298
137
102
92
72
70
64
61
61
57
54
51
40
35
24
19
18
13
11
6
6
6
6
3
3
3
2
2
2
1
Ownership
7
949
538
272
50
5
3
1
Within keyword
Active filters:
Showing 1–37 of 1818 tenders matching your filters
1.
Defence #11474287 AOC
Bids Are invited for Procurement And Installation Of Ductable Air Conditioner For Galley And Other Office Spaces Air Cooled Ducted Split Air Conditioner With Power Saving Imported Danfoss Scroll Compressor Danfoss Sporian Expansion Valve Polyester Powder Coat Capacity , Sitc Of Copper Refrigerant Piping With Necessary Supports Fittings Insulation , Sitc Of 6C X 1 5 Sqmm Copper Cable Between Indoor And Out Door Unit With Necessary Earthing Glands , 32Mmpvc Drain Piping , Supply Of R22 Gas , Installation Testing And Commissioning Along With Lifting Charges Of Indoor Unit Out Door Unit , Supply And Installation Of Factory Fabricated Galvanised Steel Sheet Ducting With Gi Threaded Rods And Gi Slotted Angles Guage 22 Guage , Sitc Of Accoustic Installation With 13Mm Nitrle Rubber With Adhesive , Sitc Of Thermal Insulation With 9Mm Thick Nitrle Rubber With Adhesive , Sitc Of Aluminum Thermal Powder Coated Sipply Air Ret Air Continues Grill With Out D Ers - Sitc Of Aluminum Thermal Powder Coated Supply Air Ret Air Continues Grill With Out D Ers , Supply And Installation Of Aluminium Power Coated Supply Air Return Air Jet Diffusers , Canvass Connections , Manufacturing And Fittment Of Water Proof Trap Door Made Of 18Mm Water Proof Termite Proof Board With 2Mm Aluminum Grid Support - Manufacturing And Fittment Of Wat Er Proof Trap Door Made Of 18Mm Water Proof Termite Proof Board With 2Mm Aluminum Grid Support , Core Cutting , Electrical Supply From Indoor To Out Door Unit From Main Disturbation Panel , Scuff Folding Work , Manufacturing Of Galvanised 200Mtr Ducting With Power Coating Vents - Manufacturing Of Galvanised Ducting With Power Coating Vents Total Quantity : 3205
Contract Date: Ref. Documents Contract Value : 46.53 Lakh
Government Departments No of Bidders 10
Andhra Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 16,510
Statutory Bodies & Commissions/Committees No of Bidders 3
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 2.05 Lakh
Boards / Undertakings / PSU No of Bidders 4
Chhattisgarh View Result →
8.
Contract Date: Ref. Documents Contract Value : 77.65 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 88,536
Government Departments No of Bidders 5
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 2.48 Lakh
Government Departments No of Bidders 4
13.
Defence #11413644 Technical Bid
Tender For Repair And Maintenance Of Chs Alongwith Connected Items At Various Units At Bhimbat,Thasgam & Drass Under Ge Kargil.- 1 Dismantling The Existing Burner Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed. 2 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For De- Carbonization , Descaling And Refractory Cement And Assemble The Same And Testing Complete All As Specified And Directed. 3 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr By Using Brush And Vaccum Cleaner Complete All As Specified And Directed. 4 M&L For Descaling Of Boiler By Circulating The Descaling Chemical Using Circulating Pump Into The Boiler And Kept It For Approx 4 Hours For Descaling And Flushing Off The Chemical After Descaling Of Boiler Complete All As Specified And Directed. 5 M&L For Refractory Cement / Heat Resistance Cement Of Boiler Assembly Of Heating Plant Complete All As Specified And Directed. 6 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 20Mm Complete All As Specified And Directed. 7 Supply And Fixing In Replacement Of Solenoid Valve Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 8 S&F In Repair Of Photo Cell Sensor Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Make - Cofi Complete All As Specified And Directed. 9 S&F In Repair Hydraulic Pressure Gauge Showing Reading 0-20 Bar With Accuracy +/- 2.5% To Be Connected With 15 Mm Dia Gi Pipe Complete With Suitable Size Of Battery Complete All Accessories And Protection Cover. 10 S&F In Repair Digital Temperature Controller (Dtc) Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 11 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 12 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 13 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 14 S&F In Repair Of Nozzel 60 Degree Complete All As Specified And Directed. Make : Danfoss Or Equivalents Make. 15 Replacement Of Old Unserviceable Minor Part For The Control Panel Including Repairing Of Wiring Etc As Per Existing, Complete All As Specified And Directed By Engr-In-Charge. 16 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 17 S&F In Repair Thermostat Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 18 S&Fin Repair Sequence Controller Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 19 S&F In Repair Contactor 25A, 230V/440V Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 20 S&F In Repair Of Contactor 230/ 440V Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 21 S&F In Repair Relay 4.5 - 7.5 Amps, 3 Phase, 50 Hz, 415 Volts Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 22 S&F In Repair Relay 6 - 10 Amps,3 Phase, 50Hz, 415 Volts Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 23 S&F In Repair Diesel Filter Assembly With Drain Port Complete As Per Sample. 24 S&F In Repair Fuel Pipe For Burner As Per Sample. 25 M&L For Complete Rewinding Of Electric Motor Of Capacity 5 Hp 3 Phase 415 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 26 M&L For Complete Rewinding Of Electric Motor Of Capacity 1 Hp Single Phase 230 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 27 All As Per Item No 26 Above But Capacity 0.5 Hp Single Phase 230 Volts. 28 Repair Of Chimney 7Mtr High Complete With Welding Including Iron Pieces, Plates, Outlet Cover And Necessary Modification And Cleaning Complete Removal Of All Kinds Of Dust Both Internal And External Parts And Free From All Kind Of Dust/Dirty Spots Of Chimney, Complete All As Specified And Directed By Engr-In-Charge. 29 M&L For Elastomeric Nitrile Rubber Foam Insulation Sheet For Ducts Having Anti Microbial Properties Having Thickness 10 Mm With Suitable Adhesive Complete All As Specified. 30 Dismantling Of Unserviceable/Damaged Hepa Filters And Supply And Fixing Of Hepa Filters With Al Box And Flange Type Of Size 640 X 460 X 50 Mm With Frame Having Efficiency Of 3 Microns Complete All As Specified. 31 M&L For Cleaning Of Existing Hepa Filters With Pressurized Potable Water By Using Pressure Pump And Water Spray Gun, Dry The Filters With Compressed Air After Cleaning Complete All As Specified. 32 Supply And Topping Up Of Antifreeze (Coolant) Suitable For -35 To -40 Degree Celsius To Be Filled In Reservoir Tank For Central Heating System As Instructed By Engr-In-Charge. 33 S&F Of Threaded Thermometer Having Range -50 To +100 Degree Celsius With Accuracy +/-2.5% To Be Fixed On 15 Mm Dia Gi Pipe Complete With All Accessories. 34 M&L For Rewinding Of Ahu Blower Motor Cap 5 Hp And Testing After Repair Complete All As Specified. 35 M&L Charges For Servicing Of Air Handling Units Including Blower Cleaning, Balancing Of Blower Motor Pully Complete All As Specified. 36 S&F In Replacement Of Supply Air Diffuser Alongwith Collar Damper Of Size 600 X 600, Neck Size 450 X 4550Mm All As Specified. 37 M&L For General Maintenance, Inspection And Servicing Of Chiller Unit By (Make-Bluestar Model No. Xac2S-010R2) Cleaning Of Condenser And Evaporator Coils Of The Chiller Unit By Using Specialized Cleaning Solution And Pressure Washing, Inspections Of The Compressor And Water Pump For Leaks, Noise, And Proper Functionality, Verifying The Integrity Of Electrical Components, Including Wiring, Breakers And Sensors, Parts, Lubrication Of Moving Parts, Checking Of Any Refrigerant Leaks, Checking Performance Testing And Optimization. 38 M&L For Repair/Replacement Of Faulty Components, Fixing Any Refrigerant Leaks And Vaccum Testing And Performance Evaluation After Refilling, Replacement Of Worn Out Gaskets, Seal And O-Rings For Chiller Of Capacity 9.2 Tr Complete All As Specified And Directed. 39 Supply And Charging Of Refrigerant Gas R-407C As Per Existing For Chiller Of Capacity 9.2 Tr And Testing After Charging Complete All As Specified And Directed. 40 Supply And Topping Up Of Compressor Oil As Per Existing Grade Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 41 Supply, Installation, Testing In Replacement Of Hermetic Type Scroll Compressor Unit , Suitable For 9.2 Tr Capacity Chiller Unit (Make-Bluestar Model No. Xac2S-010R2) Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Bluestar/Godrej / Lg Or Equivalent. 42 S&F In Replacement Of Expansion Valve As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 43 S&F In Replacement Of Filters & Driers As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 44 S&F In Replacement Of Pressure Switches As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 45 S&F In Replacement Of Control Relays As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 46 S&F In Replacement Of Fan Motor Of Cooling Tower As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 47 S&F In Replacement Of Temperature Controller As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 48 Dismantling The Existing Burner Assembly Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed By Engr-In-Charge. 49 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 30000 Kcal/ Hr For De- Carbonization And Assemble The Same And Testing Complete All As Specified And Directed By Engr-In-Charge. 50 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity Capacity 30000 Kcal/ Hr By Using Brush And Vaccum Cleaner Or Blower Complete All As Specified And Directed By Engr-In-Charge. 51 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Gun Metal Of Size 25Mm Complete All As Specified And Directed By Engr-In-Charge. 52 S&F In Repair Of Photo Cell Sensor Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr Complete All As Specified And Directed By Engr-In-Charge. 53 S&F In Repair Dtc Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 54 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 55 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 56 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 57 S&F In Repair Of Nozzel 60 Degree Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 58 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 59 S&F In Repair Thermostat Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 60 S&Fin Repair Sequence Controller Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 61 S&Fin Repair Solenoid Valve Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 62 S&F In Replacement Of Chimney Exhaust Of 6 Inch Dia Made Of Auminium Sheet Including Bends And Outlet Cover Complete All As Specified And Directed By Engr-In-Charge. 63 Dismantling The Existing Radiator Unit Of Capacity From 3000 To 6000 K Cal Per Hour, Taking It To Nearest Workshop Cleaning The Complete Unit With Coil Shine Chemical, Detecting The Leakage Portion By Applying Nitrogen Gas Pressure, Brazing The Leakage Portion, Refixing The Same Unit From Dismantled Location Including Testing On Load Complete All As Directed At Site By Engineer-In- Charge. 64 Supply And Laying 3 Layer (Inner Antimicrobial, Outer Uv Stabilized) Isi Marked Is-15801 Pp-R Pipe And Pp-R Plain Fittings In Walls Or Laying In Floors Complete Of Size Outer Dia 25 Mm Including All Fittings (Surface Remitting Also Included). 65 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 25Mm Complete All As Specified And Directed. 66 S & F In Replacement Thermostat Suitable For 126/165/195/310 Litres Capacity Refrigerators All As Directed. 67 Supply And Charging Of Refrigerant Gas As Per Existing For Refrigerator Of Capacity 126/165/195/310 And Deep Freezer Of Capacity 300/320/400/500 Ltr Capacity Including Testing After Application Of Nitrogen Gas Pressure To Find Out Any Leakage, Brazing And Stopping Of All Leakage Detected, Re-Application Of Nitorgen Pressure To Ensure Leak Proof Gas Circulator System Flushing Out The Nitrogen Gas Complete All As Specified And Directed. 68 S&F In Replacement Of Compressor Unit , Suitable For 165/195 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 69 S&F In Replacement Of Compressor Unit , Suitable For 126 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 70 S&F In Replacement Of Compressor Unit , Suitable For 310 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 71 S&F In Replacement Of Copper Capillary Tube With All Fittings For Refrigerator Of Cap 126/165/310 Ltr Complete All As Specified. 72 Repair To Voltage Stabilizer For Automatic Operation Single Phase Naturally Air Cooled, Indoor Type Designed For Output Variation Between 170 To 250 V With Output Voltage Stablized At 230 V With Accuracy Of +/- 2.5 % And Capacity 1 Kva And Making Connection With Ac Complete All As Specified & Directed. 73 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 50 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 74 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 25 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 75 M&L For Replacement Of Unservicible Inner Shell Made Of Stainless Steel 1.5Mm Thick Suitable For Geyser Inclusive Of Glass Wool As An Insulating Material For Geyser Of Capacity 25-50 Ltrs. 76 M&L For Replacement Of Thermostat For Geyser 0 To 80˚ C Complete All As Specified And As Directed By Engineer-In-Charge. 77 M&L For Flexible Pvc Connection Pipe For Geyser Of Length 1.5 Feet As Per Sample. 78 M&L For Replacement Of Pressure Release Valve For Geyser Of 25 Ltr Having Size 15Mm Dia. 79 M&L For Replacement Of Heating Element For 25 Ltr Geyser Capacity Round Type 1.5 Kw As Per Sample. 80 M&L For Replacement Of Heating Element For 25 Ltr Cap Triangle Type 1.5 Kw As Per Sample. 81 M&L For Replacement Of Geyser Assembly Suitable For 25 Ltr Geyser As Per Sample. 82 Repair And Replacement Of Kerosine Oil Batti Including Blower, Burner For Hammam 500 As Per Sample Complete All As Specified And Directed. 83 S&F Brass Tap Size15/20 Mm For Hamam As Per Sample Complete All As Specified And Directed. 84 M&L For Replacement Of Heating Element As Per Sample Suitable For 500Ltr Hammam As Per Sample. 85 S&F In Repair Of Compressor New Sealed Unit, Suitable For 300/320 Ltr Capacity Deep Freezer And Testing On Full Load Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete In All Respect Complete All As Specified And Directed By Engr-In-Charge.Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 16
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 2.00 Lakh
Government Departments No of Bidders 3
15.
Contract Date: Ref. Documents Contract Value : 6.88 Lakh
Government Departments No of Bidders 4
16.
Heavy Industries and Public Enterprises #11360644 AOC
Bids Are Invited For Refrigerant Gas (Q3) Total Quantity : 744
Contract Date: Ref. Documents Contract Value : 8.77 Lakh
Boards / Undertakings / PSU No of Bidders 5
18.
Petroleum and Natural Gas #11346919 AOC
Bids Are invited for Operation & maintenance of Voltas make HVAC system (02 nos. of HVAC unit 80 Ton each in 1+1 configuration mode) at GAIL Office, Jaipur as per terms & conditions laid down in the tender documents. The job shall include attending day to day complaints of HVAC Systems along with operation, upkeep, routine maintenance of HVAC System & its associated network equipment. The normal operating hours of HVAC system will be between 8:00 Hrs. to 20:00 Hrs. which can be modified by EIC as per requirement. The job shall also include all consumables like refrigerant gas, motor windings, fuses, oil etc. as mentioned in scope of work, tools & tackles, manpower, transportation and other resources required for executing the job to keep the system in working conditions. , Bi-monthly maintenance of 1.5 TR Window ACs Comprehensive maintenance of 1.5 TR Window ACs of make Diakin/Voltas/Lloyd//Blue star or equivalent make. The scope of work also includes supply of all spares, consumables, gas, windings etc. and all tools & tackles, transportation, all taxes, services of a supervisor and other resources required for executing the job to keep the system in working conditions. Routine checkup and maintenance thereof shall be carried out bi-monthly. Apart from the monthly maintenance, the contractor shall have to attend the maintenance job of these ACs on intimation/ call as and when required without any extra payment. , Bi-monthly maintenance of 1.5 TR Split ACsComprehensive maintenance of 1.5 TR Split ACs of Diakin/Voltas/Lloyd//Blue star or equivalen make. The scope of work also includes supply of all spares, consumables, gas, windings etc. and all tools & tackles, transportation, all taxes, services of a supervisor and other resources required for executing the job to keep the system in working conditions. Routine checkup and maintenance thereof shall be carried out bi-monthly. Apart from the monthly maintenance, the contractor shall have to attend the maintenance job of these ACs on intimation/ call as and when required without any extra payment. , Bi-monthly maintenance of 2.0 TR Split ACs Comprehensive maintenance of 2.0 TR Split ACs of Diakin/Voltas/Lloyd//Blue star or equivalen make. The scope of work also includes supply of all spares, consumables, gas, windings etc. and all tools & tackles, transportation, all taxes, services of a supervisor and other resources required for executing the job to keep the system in working conditions. Routine checkup and maintenance thereof, shall be carried out bi-monthly.Apart from the monthly maintenance, the contractor shall have to attend the maintenance job of these ACs on intimation/ call as and when required without any extra payment. , Bi-monthly maintenance of 4 TR Cassette 3 Ph. Split ACs of Voltas make.Comprehensive maintenance nos. of 4.0 TR Cassette 3 Ph. Split ACs of Diakin/Voltas/Lloyd//Blue star or equivalen make. The scope of work also includes supply of all spares, consumables, gas, windings etc. and all tools & tackles,transportation, all taxes, services of a supervisor and other resources required for executing the job to keep the system in working conditions. Routine checkup and maintenance thereof shall be carried out bi-monthly. Apart from the monthly maintenance, the contractor shall have to attend the maintenance job of these ACs on intimation/ call as and when required without any extra payment. , Bi-monthly maintenance of 4 TR Tower AC 3 Ph. Split ACs Comprehensive maintenance of 4 TR Tower AC 3 Ph. Split ACs of Diakin/Voltas/Lloyd//Blue star or equivalen make.The scope of work also includes supply of all spares, consumables, gas, windings etc. and all tools & tackles, transportation, all taxes, services of a supervisor and other resources required for executing the job to keep the system in working conditions. Routine checkup and maintenance thereof shall be carried out bi-monthly. Apart from the monthly maintenance, the contractor shall have to attend the maintenance job of these ACs on intimation/ call as and when required without any extra payment. , Maintenance & painting of Cooling Tower and Cooling Water pipeline.(i) Maintenance of Cooling towers including cooling tower cleaning (once in 2 years), tank cleaning, proper up-keeping of cooling towers, cleaning of cooling tower area etc. (ii) Painting of 2 nos. Cooling Tower of approximate 70 M2 surface areas and painting of cooling water pipeline (8” dia., of approximately 20 M length). Scope includes surface preparation, supply and application of primer & finish paint, supply of wire brush, paint brush, all consumables and all tools & tackles, transportation, all taxes, services of a supervisor and other resources required for executing the job. , 3 Way Valve: Supply, Installation, testing & Commissioning of 3 way mixing valves with actuator and Temperature controller for HVAC system. Supply, installation, testing & commissioning of 3 way mixing valves with actuator and Temperature controller for HVAC system. Make: Honeywell. The job shall also include all consumables like gas kit, nut-bolts, insulation, wires etc. The job shall also include tools & tackles, manpower, transportation and other resources required for executing the job to make the system in working conditions. , Bi-monthly Maintenance of Water Cooler Comprehensive maintenance of Water Cooler at GAIL Bhawan. Make: Voltas. Capacity: 80 Ltr. Refer Scope of work. , De-installation, Installation & Commisioining of 1.5 / 2 TR Split AC De-installation, Installation & Commisioining of 1.5 / 2 TR Split AC with fixing of indoor & outdoor units and other related work along each split unit (On as & when required basis).
Contract Date: Ref. Documents Contract Value : 36.96 Lakh
Boards / Undertakings / PSU No of Bidders 3
19.
Heavy Industries and Public Enterprises #11346786 AOC
Bids Are Invited For Refrigerant Gas (Q3) Total Quantity : 360
Contract Date: Ref. Documents Contract Value : 3.78 Lakh
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
23.
Power #11329012 AOC
Bids Are invited for Boq For Ac And Cooler Repairing Work Fabrication Of Tanks Of Coolers - Fabrication Of Tanks Of Coolers With G.P. Sheet Of 18 Swg And Fixing It To The Existing Body Including Riveting, Welding Etc. Also Painting Of Fabricated Body With On Coat Of Ready Mix Paint And Two Coats Of Quality Paint Of Asian, Berger, Nerolac Of Any Other Make Of Approved Shade Including Cost Of All Labour Material, T And P Etc. Required For Proper Completion Of Work. , Fabrication Of Cooler Body - Fabrication Of Cooler Body With G.P. Sheet Of 18 Swg For Tank Or Top, Rest Body Of 22 Swg And Fixing Of Fan And Pump To New Body Including Rewetting Welding And Supplying And Fixing Wire Mesh And Wood Wool. Wire With Plug And Painting Fabricated Body With On Coat Of Ready-Mix Paint And Two Coats Of Quality Paint Of Asian, Berger, Nerolac Of Any Other Make Of Approved Shade Including Cost Of All Labour Material, T And P Etc. Required For Proper Completion Of Work. , Supply And Fixing Of Wood Wool. , Supply And Fixing Of Pipes And Pump. , Rewinding Of Exhaust Fan And Motor Of Air Coolers. , Painting Of Air Coolers. , Supply And Installation Of Pedestal And Wall Mounted Fan. , Servicing Of Air Conditioners Including Attending All The Defects , Refilling Of Refrigerant Gas In Air Conditioner. , Supply And Fixing Of Compressor - Supply And Fixing Of Compressor Of Ac Including Dismantling Old Compressor And Fixing New One. , Special M And R Of Air Conditioner - Special M And R Of Air Conditioner Lying In Damage Condition Including Cost Of All Labour, Material And Replacement Of Damaged Part, Gas Charging, Rewinding Of Motors Etc, Complete Job So As To Bring It To Proper Running Condition. Total Quantity : 199
Contract Date: Ref. Documents Contract Value : 3.36 Lakh
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
26.
Heavy Industries and Public Enterprises #11321092 Technical Bid
Tender For Civil And Mep Works For Setting Up Hindlabs Minor Lab, Barpeta, Assam- 1 Civil Works 2 Solid Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20X15Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete 3 12 Mm Cement Plaster Of Mix:1:6 (1 Cement : 6 Fine Sand). 4 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 5 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 6 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 7 Providing And Laying Premiumvitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier,Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt/Antiskid Finish Of Size Size Of Tile 600 X 1200 Mm 8 Providing And Laying Premium Vitrified Wall Tile In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600 X 1200 Mm 9 Providing And Fixing Fiber Glass Reinforced Plastic (Frp) Door Frames Of Cross- Section 90 Mm X 45 Mm Having Single Rebate Of 32 Mm X 15 Mm To Receive Shutter Of 30 Mm Thickness. The Laminated Shall Be Moulded With Fire Resistant Grade Unsaturated Polyester Resin And Chopped Mat. Door Frame Laminate Shall Be 2 Mm Thick And Shall Be Filled With Suitable Wooden Block In All The Three Legs. The Frame Shall Be Covered With Fiber Glass From All Sides. M.S. Stay Shall Be Provided At The Bottom To Steady The Frame. 10 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 11 Providing And Fixing To Existing Door Frames.30 Mm Thick Fiberglass Reinforced Plastic (F.R.P) Flush Door Shutter In Different Plain And Wood Finish Made With Fire Retardant Grade Unsaturated Polyester Resin, Moulded To 3 Mm Thick Frp Laminate All Around, With Suitable Wooden Blocks Inside At Required Places For Fixing Of Fittings And Polyurethane Foam (Puf) / Polystyrene Foam To Be Used All Filler Material Throughout The Hollow Panel, Casted Monoolithically With Testing Parameters Of F.R.P. Laminate Conforming To Table - 3 Of Is : 14856, Complete As Per Direction Of Engineer- In-Charge. 12 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 13 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 14 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 15 Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 With C.I. Brackets And Stainless Steel Plug 40 Mm,With Swan Neck Faucet With Pipe In Let And Drain Provision, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:Kitchen Sink With Drain Board510X1040 Mm Bowl Depth 250 Mm 16 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms 17 Providing And Fixing Cp Towel Rod Complete Fixed With Cp Brass Screws Of Approved Quality Of Minimum 600Mm Length Approved As Per The Requirement Of Engineer In Charge. 18 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions: 45 Cm Length15 Mm Nominal Bore 19 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 40 Mm Dia 20 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 21 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 15 Mm Pipe 10Kgf/Cm2 22 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work,Including Cutting Chased And Making Good The Wall Etc. 20 Mm Pipe 12 Kgf/Cm2 23 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall 24 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clips/ At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 Mm Dia 6 Kgf/Cm2 - External Work- Exposed On Wall 25 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia 45 Degree Elbow 26 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75X75X75 Mm Dia Door Tee 27 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 75 Mm Dia Bend 28 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 10 Kgf/Cm2 29 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes,Including Jointing With Pvc Solvent Cement - 75 Mm Dia Vent Cowl 30 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -75 Mm Dia End Cap 31 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement -110 Mm Dia End Cap 32 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X110 Mm Dia Door Tee 33 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 34 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/Clips At 1.00 M Spacing. This Included Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 75 Mm Dia 6Kgf/Cm2 - External Work- Exposed On Wall 35 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Partition Of Approved Brand And Manufacture, Including Top & Bottom Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Fittings, All Complete As Per Direction Of Engineer-In-Charge. 36 Providing And Fixing 12 Mm Thick Frameless Toughened Glass Door Shutter Of Approved Brand And Manufacture, Including Providing And Fixing Top & Bottom Pivot & Double Acting Hydraulic Floor Spring Type Fixing Arrangement And Making Necessary Holes Etc. For Fixing Required Door Fittings, All Complete As Per Direction Of Engineer-In-Charge ( Door Handle, Lock And Stopper Etc To Be Paid Separately) 37 Providing And Fixing Ss H Handle Having Min 45 Cm Length In Toughed Glass Door Including All Necessary Screws Etc. Complete. 38 Providing And Fixing 3M Fasara Frosted Etching Film Of Thickness 25 Microns Self- Adhesive Of Approved Colour, Shade, And Quality With Cutting As Per Approved Design And Pattern, Including Cleaning Of Glass And Making Surface Smooth For Fixing Of Film To The Surface, All Completed As Per The Direction Of The Engineer In Charge. 39 Providing And Fixing Of Glass Door Ss Patch Lock With Out Handle In Toughened Glass Door Including All Necessary Screws Etc. Complete 40 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 41 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 42 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides 43 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 44 Filling The Gap In Between Aluminium/ Stone/ Wood Frame And Adjacent Rcc/ Brick/ Stone/ Wood/ Ceramic/ Gypsum Work By Providing Weather/Structural Non Sag Elastomeric Pu Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete,Complying To Astm C920, Din 18540-F & Iso 11600Upto 5 Mm Depth And 5 Mm Width 45 Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 46 Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete.Single Rubber Stopper 47 Providing And Fixing Bright Finished 100 Mm Mortice Lock With 6 Levers Without Pair Of Handles Of Approved Quality For Aluminium Door, With Necessary Screws Etc Complete As Per Direction Of Engineer- In- Charge. 48 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 49 Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised(Anodic Coating Not Less Than Grade Ac 10 As Per : 1868), Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:300X10 Mm 50 Vinyl Transparent Vision Glass Stickers: Supply And Pasting Of Vinyl Transparent Vision Glass Stickers In Approved Size And Design In Glass Partition And Door As Per The Instruction Of Engineer In Charge. 51 Backlit Acrilic Board With Projected Letters: Supply, Installation, Testing And Over Suitable Welded And Painted 25X25X3Mm Ms Angle Frame In Suitable Location And In Proper Line And Level With All Necessary Fastners, Supports Etc. Electrical Works Likes Electrical Wirings, Connections, Fittings, Externaly Fixed Weather Proof 2/3 Pin Plug Points And Sockets Including Boxes Etc. To Be Complete Properly. All Fabrication And Fixing Should Be Done As Per Approved Design And Instructions Of Engineer In Charge. (Note: Only Front Elevation Will Be Measured.) 52 Furniture 53 Supply And Erection Of Airport Type 3 Seater Waiting Chair With Powder Coated Chromium Finish Having Minimum Dimensions 1675Mm Length X 710Mm Width X 775Mm Total Height And 400Mm Seat Height . Seat: High Quality Cold Rolled 1.2Mm Thick Steel Perforated Sheet Pressed And Welded To Form The Shape. Arm & Leg: High Quality 1.2Mm Thick Ms Tube / Sheet . Cross Bar: High Quality Cold Rolled 2Mm Thick Steel Sheet Pressed And Welded To Form The Shape. 54 Supply Of Phlebotomy Chair With Optimum Design Made Up Of Ms Power Coated Frame And Up Upholstery Type Seat,Back Rest And Arm Rests.Both Side Arm Rest Should Be With Height And Position Adjustable System And All As Per The Instruction Of Engineer In Charge. 55 L-Type Workstation Of Overall Size (1350 * 600)Mm + (1000 * 450)Mm X 750 Mm (L X D X H) And Pedestal Unit Made Up Of 18 Mm Thick Exterior Grade-I Mdf Board On All Sides Conforming To Is:14587 From Approved Makes Such As Century/Greenply/Fineply Or Equivalent With Decorative Laminate On Both Side And All Edges To Be Fixed With 2Mm Thick Pvc Edge Beading. One Three-Drawer Modular Pedestal Unit Of Minimum Size 450 Mm (W) X 500 Mm (D) X 650 Mm (H) All With Retractable Key Board Tray, Drawer Channels, Hinges, Handles, Individual Locking System, And All Necessary Fittings And The Workstation Should Have An Electrical Flip Box With 2 Nos Universal Power Socket & 1 No Data Socket Etc And Cable Management Tray. All Work As Per The Approved Design And Instruction Of The Engineer-In-Charge/Architect. 56 Providing And Erection Of Reception Counter Table Of Length 1200 Mm And First Level Should Be Provided At A Height Of 750 Mm And Width 600 Mm And The Second Level At A Height Of 1050Mm From Base With A Width Of 300. The Table Made Of 18Mm Thick Pre Laminated Medium Density Board Of Exterior Grade (Grade I) Is: 14587:1998 With Decorative Laminated Finish On Both Sides And 2 Mm Thick Pvc Beading On All Edges, Including Electrical Flip Box, Cable Measurement Tray, Grommets With 3 Nos Universal Power Socket And Ethernet Port, Three Drawer Pedestal Unit With Drawer Channel, Handles, Hinges, Lock All Complete As Per Approved Drawing And Installation Of Engineer In Charge/Architect. 57 Supply And Installation Of Visitors Chair Medium Back, Mesh Back Cushion Seat With Fixed Supports Made Of 304 Stainless Steel/ Powder Coated Ms Of Approved Colour Or Shade As Per The Instruction Of The Engineer In Charge 58 Revolving Chair: Medium Back Ergonomic Chair With Five Nos. Star Shaped Nylon Base. Castor: 50Mm Diameter Nylon Twin Wheel, Gas Lift Height Adjustment, Back Angle Adjustment , Fixed Armrest Providing Natural Resting For Arms. Seat With Pu Coated Foam Backed Fabric, Back Rest With Mesh Type Fabric, Upholstery: Heavy Duty Rubber Backed Fabric In Black 59 Counter Height Stools :Supply And Erection Of Counter Height Stools ( Bar Stools ) Of Following Specifications : Revolving Adjustable Chrome Plated Steel Body Chairs With Resistance To The Corrosion. Cushion Seat With Lift Mechanism For Adjustment Of Height. Minimum Height 750Mm Before Expansion. Medium Back Rest And Arm Rest. Item Shall Be Of Reputed Make. 60 Supplying And Fixing Of Lab Work Table With 18 Mm Thick Edge Moulded Granite Top Supported Over 18Mm Thick Marine Ply Wood Of 2500Mm,L X 1200Mm,W X 850Mm, H And Powder Coated Gi Frame Of Section Size Not Less Than 50X50X1.5 Mm Including And Providing 4 Nos Under Storage Movable Cabinents Of Size 600Mm,L X 450Mm,D X 750 Mm,H And Powder Coated Steel Sheet Of Thickness Not Less Than 1Mm With 1 Drawer And Partition Bottom Storage Space With Door Including Drawer Channels, Individual Locks And Handles All As Per The Approved Drawing And Instructions Of Engineer In Charge 61 Lab Work Bench -The Work Bench Top Made Up Of 18Mm Thick Granite Top Edge Moulded Over 18 Mm Thick Marine Plywood And Gi Powder Coated Frame Work Of Section Size Not Less Than 50X50X1.5Mm. The Width Of The Table Shall Be 750Mm And Height Shall Be 850Mm. The Frame Provided With Level Adjusting Screws Fixing Accessories ,Carriage Of Material All Complete As Per The Approved Drawings And Direction Of Engineer In Charge.Note Only Length Of The Table Shall Be Measured For Making Payment. 62 Cabinet/Wardrobe: Providing And Errection Of Cabinet/Wardrobe Unit Made With 18 Mm Thick Prelaminated Mdf Board Of One Side Decorative Lamination And Other Side Balancing Lamination Having Total Unit Dimension Of 900Mm,L X 450Mm,Dx 2400Mm,H And All Edges To Be Sealed With Pvc Edge Beeding Of 2.00 Mm Thick Including All Fittings Such As Autoclose Hinges,Chromium Plated Brass Individual Locks & Handles ,Tower Bolts Etc All Required. All Shelves To Be Fix With Proper Support And Bracket Holders At A Spacing Of 400 Mm Centre To Centre And All As Per The Drawings And Instruction Of Engineer In Charge. Board Make : Greenlam/ Merino / Century/ Equivalent . Only Front Elevation Will Be Measured. 63 Overhead Storage: - Providing And Fixing Overhead Storage Unit With Minimum 18 Mm Thick Pre-Laminated Medium Density Fiber Board Exterior Grade (Grade-I) Is: 14587:1998 Marked With One Side Decorative And Other Side Balancing Lamination. Cupboard Shutters Edge To Be Sealed With Pvc Edge Bending Tape 2.00 Mm Thick Of Approved Brand Including Isi Marked Nickel Plated Bright Finishing M.S. Piano Hinges Conforming To Is:3818 Marked With Fixing Chromium Plated Brass 50 Mm Cupboard Or Wardrobe Knobs, Special Quality Chromium Plated Brass Cupboard Locks With Six Levers Of Approved Quality Including Necessary Screws Etc. Complete. Only Front Elevation Will Be Measured. 64 Electrical- Wiring 65 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 66 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 67 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 68 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Offrls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessedmedium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 69 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earth Wire 70 Fixtures 71 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socketoutlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Beused In Non Residential Buildings) 72 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front Onsurface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Ampsmodular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required 73 Supplying & Fixing Suitable Size Gl Box Wih Modular Plate And Cover In Front Onsurface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25A Modular Sp Mcb, C Curve Including Connections, Painting Etc. Asrequired. 74 Supply, Installation Of Surface Mounted Led Tubelight. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification. Luminaire Shall Be Designed To Emit At Least 3600Nominal Lumens And Efficacy Of Atleast 105 Lumen/Watt And Minimum System Wattageof 30 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Upto 30% Over 25K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. Make - Philips, Crompton, Wipro, Havells 75 Supply And Installation Of Surface/Recess Mounted Led Round/Square Luminaire With Crca Housing Suitable With Fully Diffused Diffuser For General Lighting In Offic Eareas. The Luminaire Should Have Cri 80 And Cct Of Both 6500K/5700K, Cool White Light. The Luminaire Shall Be Compliant With Ip20 And Ik02 Classification.Luminaire Shall Be Designed To Emit At Least 1000 Nominal Lumens And Efficacy Ofatleast 105 Lumen/Watt And Minimum System Wattage Of 10 -15 Watts. The Luminaire Shall Be Designed So As To Ensure Lumen Depreciation Of Up To 30% Over 50K Burning Hours. The Electronic Driver Used Shall Have A Power Factor 0.95 And Thd. For Light Fittings To Be Installed In False Ceiling, All Required Cuttings Shall Be Made And Damages Shall Be Made Good As Per The Direction Of Engineer In Charge. Make-Philips, Crompton, Wipro 76 Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizes Using Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With Pvc Insulated And Pvc Sheathed 650/1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 1200Mm Sweep - 5 Star Rated, 3 Blade Ceiling Fan Complete With 300Mm Down Rod, Canopies,Shackles. 77 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existingmodular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 78 Supplying, Conveyance And Installation Of 3 Blade, 400 Mm Sweep, 1400 Rpm Wall Mount Fan Including Frames And All Mounting Accessories Complete. Recommended Make: Usha/ Havells/ Bajaj / Almonard Or Equivalent 79 Supplying, Conveyance And Installation Of 150 Mm Sweep,1800 Rpm Exhaust Fanincluding Frames And Allmounting Accessories Complete. Recommended Make: Usha/Havells/Bajaj Or Equivalent 80 Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required. 81 Supplying And Fixing Brass Batten/ Angle Holder Including Connection Etc. As Required. 82 Supply, Installation Of 12 Watt Led Bulb. 83 Db And Switchgear 84 Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+18) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) 85 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door 86 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 87 Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. 88 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 89 Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existingmcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63Amps 90 Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30Milli Amperes In The Existing Mcb Db Complete With Connections, Testing Andcommissioning Etc. As Required.63 Amps 91 Supplying And Fixing Cable End Boxes (Ip 43) Suitable For Following Single Poleand Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess,Complete With Testing And Commissioning Etc. As Required.For 6 Way, Double Door Spn Mcbdb 92 Cctv And Networking 93 Supply, Conveyance And Installing Of 2Mp Ip Dome/Bullet Camera Having 1/3Progressive Scan True Day And Night Colour Ir Camera Having Effective Pixel Of 2Mp, Video Frame Rate Of 2Mp @30Fps, Minimum Illumination Of 0.01 [email protected], 0Lux@Ir On, 20 M Ir Range, 24 Ir Led, Awb, Agc, Blc, 2D Noise Reduction,With 3.6Mm Board Lense, 12 Vdc, Poe Ip67 Rated Weatherproof Performance. 1 Year Warranty. Make: Bosch/Cp Plus/Honeywell Or Equivalent 94 Supply, Installation And Integration Of 8 Channel Embedded Linux Poe, Nvr (Network Video Recorder), Having Dual Core Embedded Processor, Must Connect 8 Channel Ip Cameras , Should Support Min 2 Sata Hdd Each Of 6Tb And Must Recordvideo Simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smartevent, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(Hevc)/H.264+/H.264, 2 Year Warranty, Image Quality Should Be Maintainedthroughout The Warranty Period. Make: Bosch/Cp Plus/Honeywell Or Equivalent 95 Supply And Installation Of Network Switch. 8 Port Poe Switch 1000Base-T Copper Ethernet Poe+ Connections, 10M/100M/1G Rj-45 Copper Ports, 1000Base-X Fiber Sfp Ports, 8 Port Auto Sensing 10/100/1000 Mbps Poe, Minimum Cpu Memory 512 Mb With 2 Sfp/Combo Ports, Energy Efficient Ethernet (Ieee 802.3Az). Make: Cisco/Cp Plus/ Netgear Or Equivalent 96 Supply And Fixing Of 6U Wall Mounting Rack With Supply And Fixing Of Mounting Brackets For Support Lockable Front Door And Detachable Side Doors, Cable Manager And Pdu Of 4 Or 6 Sockets Including Cooling Fan With Accessories Complete 97 Supply And Installation Of 8Tb Hard Disk 98 Supply And Installation Of Led Color Monitor Of Minimum 32 Inch Screen, Complete,Uhd Display Make: Lg/Samsung/Panasonic Or Equivalent. 99 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable 100 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 101 Supplying And Fixing Rj45 Outlet Including Cover Plate, Keystone Jack And Gang Box Supporting, Connection Etc. As Required 102 Air Conditioning System 103 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Followingcapacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Single Phase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 2 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 104 Supply, Installation, Testing And Commissioning Of Split Air Conditioner Of Following Capacity And Specifications: Consisting Of High Wall-Mounted Type Room Unit (Fan Coil) With Cordless Remote Control And One Number Outdoor Condensing Unit Comprising Of Energy-Efficient Suitable Rotary Compressor For Operation On Singlephase, 230 V, 50Hz Supply, Fixing The Outdoor Unit On A Raised Platform As Per Manufacturers Recommendation And Fixing Of Room (Fan Coil) Unit On Wall, Standard 4 M Distance Refrigerant Copper Piping With 13Mm Nitrile Rubber Insulation, Providing And Making Interconnection Between Room & Condenser As Per Site Conditions, Comprising Of 1Inch Dia Drain Pvc Pipe With Insulation Up To 4 M, Canvas Connections, Full Electrical Cabling From Power Plug Near Indoor Unit And To Outdoor Unit, Odu Ms Stand, First Charge Refrigerant Gas, Suitable Stabilizer Etc Complete As Required. (Make: Voltas, Blue Star, Hitachi, Carrier Or Equivalent). 1.5 Tr 3 Star Rated (Inverter Type Ac) As Per Bee 105 Supply And Installation Of Additional Copper Piping, Cabling From Indoor To Outdoor And Drain Piping For Air Conditioning Unit With Proper Insulation Including All Required On Wall/Above False Ceiling Complete 106 Supply, Installation, Testing And Commissioning Of True On-Line Double Conversion 6 Kva Ups System With 1:1 Crest Factor Single Phase Phase Input – Singlephase Output. Inversion Shall Be Microprocessor Controlled With Instantaneous Sine Wave Control Using Igbt. Ups Shall Have Standard Display Features, Alarms, Safeties, Etc Input Voltage Range : A) Phase & Single Phase With Ground B)Votage Range 190 Vac & 250 Vac C)Input Frequency : 50/60 Hz D)Power Factor : 0.95 Or Above E)Thd : Less Than 5% With Full Load Bypass F) Voltage Range & 200Vac & 240 Vac G) Frequency Range – 45-55 Hz/55-65 Hz Output Voltage Range H)Voltage Range & 200Vac & 240 Vac I)Frequency Range & 50/60 Hz J)Voltage Distortion & Linear Load = 2% K)Voltage Distortion – Nonlinear Load = 5% L)Output Waveform – Pure Sinewave M) Minimum Back Up Time : Continuous 60 Minutes At Full Load Rectifier Shall Be Full Wave Type (Shall Fully Meet The Specified Input Power Requirements) Battery Type: Sealed Lead Acid Maintenance Free Dc Voltage : 24/48/96V Dc System, Battery Nos And Capacity Shall Be Designed For Optimum Storage Space. Make: Liebert Vertiv/Apc By Schneider/Numeric By Legrand 107 Visi Cooler And Refrigerator 108 Supply And Installation Of 260 Litre Refrigerator, Direct-Cool Model With A Minimum 3-Star Bee Rating And Stabilizer-Free Operation. It Shall Use Eco-Friendly Refrigerant (R600A) And Have A High-Efficiency, Low-Noise Compressor. The Unit Shall Include Toughened Glass Shelves, A Vegetable Crisper, Bottle Storage For 2L Bottles, An Internal Freezer Compartment, And A Removable Anti-Bacterial Gasket. It Shall Operate On 230V, 50Hz Ac And Include Standard Accessories Such As An Ice Tray And Egg Tray. The Refrigerator Shall Have 1-Year Comprehensive Warranty And 10-Year Compressor Warranty, With Bis Certification.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Jun 20, 2026 Contract Value : 4.66 Lakh
Government Departments No of Bidders 1
West Bengal View Result →
29.
Civil Aviation #11317932 AOC
Bids Are invited for Title1 - Supply of 1.5 TR Inverter type, 5 star rating as per latest BEE norms, Hiwall, Split airconditioner with rotary compressor operating on refrigerant R-32A/R-410A. The body of indoor unit shall be made of ABS/HIPS/GS condensing unit should be of 100% copper coil & having all safety, air filters, evaporator, condenser, cordless remote, electronic operation control & all accessories supplied with the unit by OEM etc as per manufacturer standards suitable for operation on 230 volts, 50 Hz, Single phase, AC supply, complete as required at site. , Title2 - Supply of 2.0 TR Inverter type, 5 star rating as per latest BEE norms, Hi-wall, Split airconditioner with rotary compressor operating on refrigerant R-32A/R-410A. The body of indoor unit shall be made of ABS/HIPS/GS condensing unit should be of 100% copper coil & having all safety, air filters, evaporator, condenser, cordless remote, electronic operation control & all accessories supplied with the unit by OEM etc as per manufacturer standards suitable for operation on 230 volts, 50 Hz, Single phase, AC supply, complete as required at site. , Title3 - Installation, testing, commissioning of 2.0/1.5 Ton Split inverter A/C i/c supply & fixing of Iron Angle structure stand suitable for outdoor unit, makeup interconnection, top up refrigerent, painting i/c necessary Civil works complete as required, providing suitable size PVC pipe for drawing the gas/drain pipe and wire etc through the concrete/brick wall as required. , Title4 - Supply & fixing of extra copper refrigerant piping for suction and delivery line with all accessories suitable for following capacity ACs i/c Insulation, gas refiling, power & Control cabling etc completed as required.of standard gauge for installation of above units as required at site. , Title5 - Supply & fixing of hard PVC drain piping of proper dia for installation of above units as required at site beyond company provided standard length. , Title6 - Supply, Installing, Testing and Commissioning of 5KVA Voltage Stabilizer suitable for 1.5/2.0 TR split AC units on wall including providing connections etc. as required. (Model-V Guard VGB 500 or equivalent). , Title7 - SITC of Industrial type RO water purifier having capacity minimum 50 LPH Capacity with UV & Membranes, sediment filter, carbon filter, TDS control, water level sensor, 3 prefilter (1 carbon candle and 2 micron filter), auto flush & output water etc as per manufacturers specifications i/c, making inlet and outlet water connections with water cooler complete. Suitable for operation on 230 V, single phase, 50 Hz AC supply. , Title8 - Supply of Water cooler of fully stainless steel body with Thermostate cut- off automatic operation having cooling capacity 40 Ltr. Per hour and storage capacity 80 Ltr per hour, working on 220 V , 50 Hz ,AC supply including automatically controls with temperature, over load protection , water line connection etc. complete as required . , Title9 - Supply of Desert Air cooler (Duct Type) with following minimum specifications as given below.Fan size - 18 Inch & above.Fan speed - 1400rpm/ 3 speed.Water Tank Capacity - 110 Litres & Above - jointless tank.Material of cooler body/sump tank - Galvanized steel sheet (ISI marked to IS 277 latest)Cooling Media - ASPEN/Wood Wool.Cooling area - 500Sqft & Above.Cooling pads - On 4 Sides. , Title10 - Supply of FRP wall support ladder of size 12Feet meeting specifications as provided in the technical specifications of the agreement of the work(Make - Arham/Ladderman/Sumer/Y-access) , Title11 - Supply of FRP wall support ladder of size 20Feet meeting specifications as provided in the technical specifications of the agreement of the work(Make - Arham/Ladderman/Sumer/Y-access) , Title12 - Supply of FRP tiltable telescopic tower ladder of size 32Feet meeting specifications as provided in the technical specifications of the agreement of the work. (Make - Arham/Ladderman/Sumer) Total Quantity : 85
Contract Date: Ref. Documents Contract Value : 12.54 Lakh
Boards / Undertakings / PSU No of Bidders 5
Madhya Pradesh View Result →
30.
Metro Rail #11312106 AOC
Supply Of refrigerant gas r-407c
Contract Date: Jun 19, 2026 Contract Value : 5.22 Lakh
Government Departments No of Bidders 1
West Bengal View Result →
31.
Contract Date: Ref. Documents Contract Value : 4.89 Lakh
Government Departments No of Bidders 4
32.
Defence #11297316 AOC
Bids Are invited for SOPPLY OF AIR COOLED DUCTED SPLIT AIR CONDITIONER EUIPEED WITH POWER SAVING MPORTED DANFOOSS SCROLL COMPRESSOR DANFOSS SPORIAN EXPANSION VALVE FOR OPTIMAL REFRIGERANT FEED GALVANISED STEEL , SITC OF COPPER REFRIGERANT PIPING WITH NECESSARY SUPPORTS FITTINGS INSULATION , SITC OF COPPER CABLE BETWEEN INDOOR AND OUT DOOR UNIT WITH NECESSARY EARTHING GLANDS AND LUGS PROPER SUPPORT - SITC OF COPPER CABLE BETWEEN INDOOR AND OUT DOOR UNIT WITH NECESSARY EARTHING GLANDS AND LUGS PROPER SUPPORT , 32MMPVC DRAIN PIPING , SUPPLY OF R22 GAS , INSTALLATION TESTING AND COMMISSIONING ALONG WITH LIFTING CHARGES OF INDOOR UNIT OUT DOOR UNIT , SUPPLY AND INSTALLATION OF FACTORY FABRICATED GALVANISED STEEL SHEET DUCTING WITH GI THRESDED RODS GI SLOTTED ANGLES GUAGE 22 GUAGE , SITC OF ACCOUSTIC INSTALLATION WITH 13MM NITRLE RUBBER WITH ADHESIVE , SITC OF THERMAL INSULATION WITH 9MM THICK NITRLE RUBBER WITH ADHESIVE , SITC OF ALUMINUM THERMAL POWDER COATED SIPPLY AIR RET AIR CONTINUES GRILL WITH OUT DAMPERS , SUPPLY AND INSTALLATION OF ALUMINIUM POWER COATED SUPPLY AIR RETURN AIR JET DIFFUSERS , CANVASS CONNECTIONS , MANUFACTURING AND FITTMENT OF WAT 1932 SFT ER PROOF TRAP DOOR MADE OF 18MM WATER PROOF TERMITE PROOF BOARD WITH 2MM ALUMINUM GRID SUPPORT - MANUFACTURING AND FITTMENT OF WAT ER PROOF TRAP DOOR MADE OF 18MM WATER PROOF TERMITE PROOF BOARD WITH 2MM ALUMINUM GRID SUPPORT , CORE CUTTING , ELECTRICAL SUPPLY FROM INDOOR TO OUT DOOR UNIT FROM MAIN DISTURBATION PANEL , SCUFF FOLDING WORK Total Quantity : 3044
Contract Date: Ref. Documents Contract Value : 47.64 Lakh
Government Departments No of Bidders 12
Andhra Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 59,895
Boards / Undertakings / PSU No of Bidders 4
Contract Date: Ref. Documents Contract Value : 80.07 Lakh
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : 23,600
Government Departments No of Bidders 5
36.
Banking and Finance #11288931 AOC
Bids Are invited for Vrf Or Vrv Air Conditioning System At State Bank Of India Rbo 2 Lucknow West 20 Hp Outdoor Vrv Or Vrf - Supply Of Air Cooled 20 Hp Outdoor Units Suitable For Cooling And Heating. Refer Technical Specification And Boq For Details. , 4 Way 2.0 Tr Vrf Cassette Indoor - Supply Of 5 Ceiling Suspended 4-Way Vrf/Vrv Cassette Type 2.0 Tr Indoor Unit In In False Ceiling With Full Function Wireless Remote And Auto Restart Feature. Refer Technical Specification And Boq For Details. , 4 Way 1.3 Tr Vrf Cassette Indoor - Supply Of Ceiling Suspended 4-Way Vrf/Vrv Cassette Type 1.3 Tr Indoor Unit In Recessed Manner In False Ceiling With Full Function Wireless Remote And Auto Restart Feature. Refer Technical Specification And Boq For Details. , Y Joints - Supply Installation Of Joints , Installation Of 20 Hp Vrv Or Vrf Outdoor - Installation, Testing And Commissioning Of Vrf 20Hp Outdoor With Gas Etc. Including Making Good Of Damages Complete In All Respects. , Installation Of 2.0 Casssette Vrf Indoor - Installation, Testing And Commissioning Of Vrv/Vrf Cassette 2.0 Tr Indoor With Gas Etc. Including Making Good Of Damages Complete In All Respects. , Installation Of 1.3 Casssette Vrf Indoor - Installation, Testing And Commissioning Of Vrv/Vrf Cassette 1.3 Tr Indoor With Gas Etc. Including Making Good Of Damages Complete In All Respects. , Commisioning Of Complete Vrf System - Commisioning Of Complete Vrf System With All Machines , Refrigerant Piping 28.6 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 28.6 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Refrigerant Piping 22.2 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 22.2 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Refrigerant Piping 19.1 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 19.1 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Refrigerant Piping 15.9 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 15.9 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Refrigerant Piping 9.5 Mm - Supply, Installation, Testing And Commissioning Of Interconnecting 9.5 Mm Refrigerant Pipe Work With (19Mm/13 Mm Thick) Closed Cell Elastomeric Nitrile Rubber Tubular Insulation Between Each Set Of Indoor & Outdoor Units As Per Specifications, All Piping Inside The Room Shall Be Properly Supported. Size (Thickness And Diameter) Of Both Copper Pipes. Refer Technical Specification And Boq For Details. , Drain Pipe 32 Mm - Supply, Installation, Testing And Commissioning Of Pvc 32 Mm Water Pipe With 6 Mm Thik Nitrile Rubber Insulation And Accessories And Taking Care To Prevent Leakages, For Water Drainage In Concealed Manner Either On Wall Or Under Floor Including Making Good Of Damages. Refer Technical Specification And Boq For Details. , Drain Pipe 25 Mm - Supply, Installation, Testing And Commissioning Of Pvc 25 Mm Water Pipe With 6 Mm Thik Nitrile Rubber Insulation And Accessories And Taking Care To Prevent Leakages, For Water Drainage In Concealed Manner Either On Wall Or Under Floor Including Making Good Of Damages. Refer Technical Specification And Boq For Details. , Control And Transmission Wiring - Supply & Fixing Of Control Cum Transmission Wiring Of 3 Core X 1.5 Sqmm Copper In Suitable Conduits Between Indoor And Out Door Unit. Refer Technical Specification And Boq For Details. , Ms Sloted Angle For Pipe Paying , Outdoor Stand For Vrv Or Vrf 20 Hp - Supply And Installation Of Robust Ms Angle, Ms Flat Fabricated Floor/ Wall Mounting Stand Suitable For 20 Hp Vrf Outdoor Units. Refer Technical Specification And Boq For Details. , Sitc Of 5 Star 3 Ton Cassette A C , Copper Pipe Refrigerant Piping For 1.5 Or 2 Tr - Copper Pipe Refrigerant Piping For 2 Tr , Interconnecting Standard Wire Cable , Drain Pipe , Ms Stand Total Quantity : 765
Contract Date: Ref. Documents Contract Value : 16.20 Lakh
Government Departments No of Bidders 5
Uttar Pradesh View Result →
42.
Communications and Information Technology  #11272066 AOC
Bids Are Invited For General Servicing Of 1.5 Or 2.0 Tr Wac Or Sac Units - General Servicing Of 1.5/2.0 Tr Wac/Sac Units Of Different Make I/C Removing From Existing Position If Reqd., Dismentling Of Faulty Parts, Cleaning The Air Filter, Cleaning The Condesor And Evaporator Coil With Help Of Chemical Solution & Water, Lubrication Of Moving Parts, Complete Checking, Testing And Minor Faults Rectification I/C Replacement Of Knobs, Setting Of Thermostate Etc Complete As Reqd. , Sitc Of 1.5 Tr Resiprocating Type Compressor - Supply Of The 1.5 Tr Capacity New Hermatically Sealed Reciprocating Type Compressor Purchased From The Authorised Dealer I/C Dismentalling Of The Faulty Compressor From Site, To And Fro Transportation Charges For Compressor And I/T/C Of New Compressor In Place Of Faulty Compressor Of Existing Wac/Split Ac Etc Complete As Required. , Sitc Of 2 Tr Resiprocating Type Compressor - Supply Of The 2.0 Tr Capacity New Hermatically Sealed Reciprocating Type Compressor Purchased From The Authorised Dealer I/C Dismentalling Of The Faulty Compressor From Site, To And Fro Transportation Charges For Compressor And I/T/C Of New Compressor In Place Of Faulty Compressor Of Existing Wac/Split Ac Etc Complete As Required. , Sitc Of 1.5 Tr Rotary Type Compressor - Supply Of The 1.5 Tr Capacity New Hermatically Sealed Rotary Type Compressor Purchased From The Authorised Dealer I/C Dismentalling Of The Faulty Compressor From Site, To And Fro Transportation Charges For Compressor And I/T/C Of New Compressor Of Existing Wac/Split Ac Etc Complete As Required. , Charging Of Refrigerant Gas For 1.5 Tr Wac Or Split Ac - Charging Of Refrigerant Gas R-22/ 32 Upto Specified Pressure In 1.5 Tr Capacity Ac Units And Pressure Testing By Nitrogen, Vaccumisation For 2 Hours, Purging With Gas And Testing, Commissioning Of The Ac Unit Etc As Reqd. , Charging Of Refrigerant Gas For 2.0 Tr Wac Or Split Ac - Charging Of Refrigerant Gas R-22/ 32 Upto Specified Pressure In 2.0 Capacity Ac Units And Pressure Testing By Nitrogen, Vaccumisation For 2 Hours, Purging With Gas And Testing, Commissioning Of The Ac Unit Etc As Reqd. , Replacement And Reparing Of Thermostate - Replacement And Reparing Of The Thermostate In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Starting Capacitor 80 To 100 Or 120 Mfd - Replacement And Reparing Of The Starting Capacitor (80-100/120 Mfd) In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Running Capacitor 36 Or 40 Mfd - Replacement And Reparing Of The Running Capacitor (36/40 Mfd) In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Relay For Wac Or Split Ac - Replacement And Reparing Of The Relay For Wac / Split Ac In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Wiring Kit For Wac Unit - Replacement And Reparing Of The Wiring Kit For Wac Unit In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Selector Switch For Wac Unit - Replacement And Reparing Of The Selector Switch For Wac Unit In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Rewinding Of Condensor Or Blower Motor For Ac Unit Incuding Replacement Of Bush - Rewinding Of Condensor/Blower Motor For Ac Unit I/C Replacement Of Bush In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Blower Fan Motor Capacitor 4 Or 6 Mfd - Replacement And Reparing Of The Blower Fan Motor Capacitor 4/6 Mfd In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Repairing Of Pcb For Wac Or Split Remote Control Unit - Repairing Of Pcb For Wac/Split Remote Control Unit In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement Of Faulty Or Irrepairable Pcb For 1.5Tr Split Ac Unit - Replacement Of Faulty / Irrepairable Pcb For 1.5Tr Split Ac Unit In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Sitc Of Blower Fan Motor For 1.5 Or 2 Tr Window Or Split Ac - Sitc Of Blower Fan Motor For 1.5/2 Tr Window/Split Ac Unit In Lieu Of Damaged I/C Connection Etc As Reqd. , Supplying, Installation Of Condensor Or Blower Fan Blade - Supplying, Installation Of Condensor / Blower Fan Blade Same As Per Existing Pvc / Metal Blade In Lieu Of Damaged I/C Fixing The Same Etc As Req. , Top Up Or Additional Charging Of R-22 Or 32 Gas - Provision Of Top Up / Additional Charging Of R-22/32 Gas Upto Specified Pressue In Existing Window Ac / Split Ac Units I/C Flushing, Gas Charging, Testing Etc Complete As Reqd. , Supplying And Drawing Of 3X2.5 Sq. Mm Frls Pvc Copper Single Core Cable - Supplying And Drawing 3X2.5 Sq. Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 6X2.5 Sq. Mm Frls Pvc Copper Single Core Cable - Supplying And Drawing 6X2.5 Sq. Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of 20Mm Medium Class Pvc Conduit - Supplying And Fixing Of 20Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Fixing Of 25Mm Medium Class Pvc Conduit - Supplying And Fixing Of 25 Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Fixing Dp Sheet Steel Enclosure With 25 Or 32Amps 240 Volts C Curve Dp Mcb - Supplying And Fixing Dp Sheet Steel Enclosure On Surface/ Recess Along With 25/32Amps 240 Volts C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Of 5 A To 32 A Rating, 240 Or 415 V, 10 Ka, C Curve, Spn Mcb - Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Single Pole And Neutral Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Of 3X2.5 Sq. Mm Pvc Frls Round Sheathed Multi Core Bright Annealed Bare Copper Cable - Supplying And Fixing Of 3X2.5 Sq. Mm Pvc Insulated And Frls Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cable For Voltage Grade Up To 1100 Volts As Per Is 694-1990 I/C Fixing On Wall With Suitable Clamp/Saddle Etc. Complete As Reqd. , Dismentalling Of Existing 1.5 Or 2.0 Tr Capacity Window Or Split Ac Units - Dismentalling Of Existing 1.5 / 2.0 Tr Capacity Window / Split Ac Units Along With Indoor / Outdoor Units & All Other Existing Accessories Including Disconnection Of Electrical Connection, Copper Piping, Drain Piping , Stand Etc. From Existing Location Of Te / Bts Site Under Ssa Concerned And Reparing Of Any Damage During Dismentling By Making Good The Same Etc. Complete As Reqd. , Transportation Of Existing 1.5 Or 2.0 Tr Capacity Window Or Split Ac Units - Transportation Of Existing 1.5 / 2.0 Tr Capacity Window / Split Ac Units Along With All Accessories Etc From Te / Bts Site Of Ssa Under Ba To Store / Any Place In Same Ssa As Directed By Engg. In Charge By Transport By Truck / Loading Vehicle I/C Loading, Unloading & Safe Handling Etc.Complete As Reqd. , Itc Of 1.5 Or 2.0 Tr Capacity Split Ac Units - Installation Of 1.5 / 2.0 Tr Capacity Split Ac Units With Indoor And Outdoor Unit I/C Fixing The Refrigerant Piping With Insulation, Cutting, Brazing, Laying The Cable Along With The Piping Connections, Repairing The Minor Leakages Of The Complete System I/C Testing, Commissioning Of Split Type Ac Unit Etc. Complete As Reqd. , Pdg And Fixing Of 1 By 4 Inch Dia Copper Refrigerant Piping - Pdg And Fixing 1/4 Inch Dia Copper Refrigerant Piping I/C Covering Of Copper Piping With Polystyrene Insulation I/C Cutting, Brazing, Jointing, Bends, Sockets Etc As Reqd. , Pdg And Fixing Of 5 By 8 Inch Dia Copper Refrigerant Piping - Pdg And Fixing 5/8 Inch Dia Copper Refrigerant Piping I/C Covering Of Copper Piping With Polystyrene Insulation I/C Cutting, Brazing, Jointing, Bends, Sockets Etc As Reqd. , Providing And Fixing 12 Mm Thick Particle Board - P/F 12 Mm Thick Particle Board On Surface Of Wall For Fixing The Indoor Unit Of Split Type Ac Unit Or Fixing / Covering The Extra Space Etc. With The Help Of Screw Complete Etc. As Reqd , Supplying And Fixing Suitable Size Ms Stand For Split Type Ac Outdoor Unit - S/F Suitable Size Ms Stand For Placement Of Split Type Ac Outdoor Unit Made Out Of 16 Gauge Powder Coated Ms Sheet I/C Fixing With Help Of 4 Nos. Fasteners For Grouting On Wall / Floor, Etc. Complete As Required. , Providing And Fixing 20 Mm Dia Heavy Duty Pvc Pipe For Drainage Purpose Of Ac Unit Including Connection Testing Etc As Required. - Providing And Fixing 20 Mm Dia Heavy Duty Pvc Pipe For Drainage Purpose Of Ac Unit I/C Connection, Testing Etc As Required. , Sitc Of Ac Smart Controller For 02 Nos. Ac Cyclic Operation For 4 Or 8 Hrs Duration Suitable For Working On Single Phase Ac Supply System - Sitc Of Ac Smart Controller For 02 Nos. Ac Cyclic Operation For 4/8 Hrs Duration , Suitable For Working On Single Phase Ac Supply System, Having Under Voltage & Over Voltage Tripping Facility And Selector Switch For Operation Of Cp 1/ Cp 2/ Auto Mode Etc Complete As Reqd. (Make- Bsc Or Similar Superior Make) Total Quantity : 1135
Contract Date: Ref. Documents Contract Value : 7.74 Lakh
Government Departments No of Bidders 5
43.
Contract Date: Ref. Documents Contract Value : 3.38 Lakh
Boards / Undertakings / PSU No of Bidders 4
47.
Communications and Information Technology  #11262069 AOC
Bids Are invited for Sitc Of Split Ac Units At Cto Kolkata Supply Of 1.5 Tr Inverter Type 5 Star Rated Split Air-Conditioner Unit - Supply Of 1.5 Tr Inverter Type 5 Star Rated Split Air-Conditioner Unit As Per Bee Star Rating, (As Per New Bee Rating Valid For 1St January 2026 To 31 December 2027 ) With Remote Control Unit, Filters, Rotary Type Compressor, Copper Tubes For Both Indoor And Outdoor Unit, Refrigerant Gas With Topping Up Of Refrigerant If Required, Transportation Of All Of The Above To The Various Sites And Supplying The Following Up To The Length Of 3 Mtrs Etc. As Required. (1) Hot And Cold Refrigerant Piping (2) Suitable Connecting Electrical Cable Between Indoor And Outdoor Unit. Note-- 1) The Manufacturers / Suppliers Shall Give A Warranty Of The Air Conditioner For 15 Months From Date Of Supply Or 12 Months From Date Of Installation, Which Is Earlier. Thereafter 9 Years (108 Months) Additional Warranty On The Compressor. , Dismantling Of Existing 1.5 Tr Split Ac Unit - Dismantling Of Existing 1.5 Tr Split Ac Unit - Indoor And Outdoor Units Alongwith Interconnecting Cu Pipe And Cable , Power Connection Cable Etc - And Storing At Place Shown By Exch In Charge Etc As Reqd , Installation, Testing And Commissioning Of The Split Ac Unit - Installation, Testing And Commissioning Of The Split Ac Unit At A Specified Location By Mounting And Fitting Indoor And Outdoor Units At Their Respective Locations , Laying And Fixing Of Both Liquid And Hot Gas Lines, Interconnecting Wiring For Both Indoor Outdoor Units Up To 3 Mtrs Length And ,Interconnecting The Indoor Unit And Outdoor Unit With Refrigerant Line, Insulating The Refrigerant Pipe With Expandable Polyethylene Foam Tubing Unit , Leak Testing Entire System ,Charging Refrigerant Gas In The Unit ,Making Power Supply Connections From The Power Point Etc Complete As Required. , Supplying And Fixing Extra Copper Pipe Line - Supplying And Fixing Extra Copper Pipe Line Both 1/4 Inch For Gas Line And 5/8 Inch For Liquid Line Or Suitable Dia To Match With The Pipeline Of The New Unit Along With Suitable Size Rubber Foam/Insulation On Surface Of The Wall I/C Necessary Flare Nuts, Suitably Brazing With The Existing Pipe Cl Ing, Making Holes In Walls, Same Etc., As Per Site Requirement. Note - The Length Of Refrigerant Pipes Supplied With Each Ac Units Is 3 Mtr. Extra Length Shall Be Paid Extra For Which Firm Shall Quote Their Unit Rates. , Supplying And Laying 4 Core 2.5 Sq. Mm Pvc Insulated And Pvc Sheathed Flexible Copper Cable - Supplying And Laying 4 Core 2.5Sq.Mm Pvc Insulated And Pvc Sheathed Flexible Copper Cable Along Refrigerant Pipe Or On Existing Conduit / Cable Tray I/C Binding With Plastic Tags For Extending Supply From Existing Industrial Socket To Indoor Unit Etc, As Required . (Make- Any Isi Mark ) . Note- The Length Of Copper Cable Supplied With Each Unit Is 3 Mtr . Extra Length Shall Be Paid Extra. , Supplying And Fixing Of Powder Coated Ms Frame Stand - Supplying And Fixing Of Powder Coated Ms Frame Stand Comprising Of Two Numbers Bracket Made Of Heavy Duty Ms Sheet To Accommodate The Condenser (Outdoor) Unit For Fixing On The Wall With Suitable Diameter And Length Of Anchor Fast Bolts And Making Good Damages Etc As Per Site Requirement . , Supplying And Fixing Of 20 Mm Dia Heavy Duty Pvc Pipe With Accessories For Drain Water Connection - Supplying And Fixing Of 20 Mm Dia Heavy Duty Pvc Pipe With Accessories For Drain Water Connection Where Ever Required Etc. Complete As Required.(Make- Any Isi Mark ) . , Supplying And Laying Of Pvc Insulated And Pvc Round Sheathed, 3 Core ,2.5 Sqmm, 1.1Kv Copper Cable - Supplying And Laying Of Pvc Insulated And Pvc Round Sheathed, 3 Core ,2.5 Sqmm, 1.1Kv Copper Cable ( Un-Aoumerd ) Including Connection , Testing Checking Etc As Complete As Required , Supplying And Fixing Dp Sheet Steel Enclosure On Surface Or Recess Along With 25,32A 240V - Supplying And Fixing Dp Sheet Steel Enclosure On Surface Or Recess Along With 25,32A 240V C Curve Dp Mcb Complete With Connections ,Testing And Commissioning Etc. As Complete As Reqd. Total Quantity : 126
Contract Date: Ref. Documents Contract Value : 2.79 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
48.
Housing Urban and Rular Development #11259231 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division Gmch Jammu. Repair/Servicing And Maintenance Of 66Tr Packaged Air Conditioning Unitsin Ward No. 19 Of Govt. Smgs Hospital, Jammu.. Mhdj/E-Nit 20 Of 2026-27 Dated: 25.04.2026 Due : 04.05.2026 Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate Including Gst To Be Quoted By The Bidder Rs. P Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Rebate On Old Parts In Percentage (%) If Any Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Net Cost Of Item Rs. P Total Amount Total Amount With Taxes Total Amount In Words , Repair/Servicing And Maintenance Of 66Tr Packaged Air Conditioning Units In Ward No.19 At Govt. Smgs Hospital Jammu. Servicing Of Blowers By Way Of Alignment Checking, Strengthening To Blower Brackets And Testing At Site - 2 Jobs. Complete Servicing Of Idu Coil And Odu Unit Chemical Or Water, As Per Site Requirement, Through Pump To Remove Unwanted Dust From It And Also Washing And Cleaning Of Air Filters, Drainage, Line Cleaning Etc. For At Least Two Times At Periodic Interval- 4 Jobs. Recharging Compressors With 20 Kg Refrigerant-R410 Gas - 1 Job. Replacing Of Worn-Out Fan Belts As Per Requirement- 6 Nos. Repair Of Outdoor Fan Motors By Way Replacement/Rewinding Of Old Damaged/Worn-Out Motors As Per Requirement - 2 Nos. Replacing Of Worn-Out/Damaged Pcbs As Per Sample- 1 Nos. Restoration By Way Of Replacement Of Worn-Out/Damaged Electrical Wires/Cables Of Assorted Sizes In Order To Replace Worn-Out/Damaged Wire/Cables Of Electrical Panel Of Idu.Replacement Of Worn-Out/Damaged Contactors - 3 Nos. And Tpn (63 A) - 3 Nos. Or As Per Site Requirements.Providing And Fitting Of Protection/ Monitoring Relays As Per Site Requirement - 1 Job. Replacement Of 150 Kva Avr Protection Relay By Way Of Supply Installation Testing and Commissioning of New Relayas Per Sample. The Job Further Includes Replacement Of Control Wiring And Replacement Of Old Worn-Out/ Damaged 4P 200 A 50 Ka Bcc At Site With New One Along By Way Of Supply Installation Testing and Commissioning of New One As Per Sample Using Special Tools And Tackles Along With Manual Labour As Per Site Requirement.Complete Job As Per Directions Of Engineer-In-Charge And Includes Cost Of Material, All Kinds Of Taxes, Labour Charges, Tools & Tackles, Other Unforeseen Materials Required For Execution Of Job And Also Involves Cost Of Technicians, As And When Required To Attend The Complaints Of Machines And Its Rectification. Moreover, All The Electro-Mechanical Materials Used Should Conform To Relevant Is/Bis/Ce Standards And Codes. Total In Figures 23 23 0.0 23 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
49.
Housing Urban and Rular Development #11259226 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division Gmch Jammu. Repair And Servicing Of Vehicle No Jk02cu 2775 Tempo Trax Of Gmch Jammu Mhdj/E-Nit 37 Of 2026-27 Dated: 09.05.2026 Due : 18.05.2026 Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate Including Gst To Be Quoted By The Bidder Rs. P Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Rebate On Old Parts In Percentage (%) If Any Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Net Cost Of Item Rs. P Total Amount Total Amount With Taxes Total Amount In Words , Repairs To The Rusted / Damaged Floor Ms Sheet Of The Rear Cabin By Removing The Rusted Damaged Stretcher From Its Installed Position And Then Cutting The Damaged Portion Floor Sheet At Various Spots By Gas Cutter And The Providing Sand Fixing Ms Sheets By Welding . The Job Includes Fabrication Of Movable Stretcher To Be Fitted In The Rear Cabin For The Patient So That It Is Adjusted On The Fixed Rails To Prevent It From Sliding When The Vehicle Is Running. The Seat And Stretcher Should Be Fabricated Of Ms Angle And Flats With Ms Sheet Fixed On Top Of It And Then 6 Thick Foam Of High Density Should Be Fixed On The Ms Sheet Top And Further A Superior Quality Rexine Artificial Leather Sheet Should Be Fixed Over The Foam Of The Stretcher And Seat. The Job Further Includes Providing And Fitting Of New Seat Covers. Complete Job Includes Cost Of Material And Labour Charges (Complete Job) , Complete Servicing Of The Engine Of Vehicle No Jk02cu 2775 Tempo Trax Of Gmch Jammu. The Job Includes Replacement Of Engine Oil,Gear Oil, Steering Oil,Coolant Along With Replacement Of Fuel Filter, Oil Filter, Air Filter And Air Conditioning Filter. The Job Includes Servicing Of Ac Including Recharging Of Gas And Allied Works. The Job Includes Complete Cleaning Of The Engine With Kerosene And Then Complete Washing Of The Vehicle. The Job Includes Cost Of Material And Labour Charges And All Taxes. Complete Job , Repairs To Gear Box Of The Vehicle By Removing It From Its Installed Position And Then Extracting Its Damaged Parts I.E Bearings, Clutch Shaft And Seals And Providing And Fitting Of New Ones As Per Samples And Then Assembling Of The Gear Box And Fitting Back In Its Installed Position. The Job Further Includes Gear Lever Replacement . Complete Job Includes Cost Of Material And Labour Charges And All Types Of Taxes Theroff. (Complete Job) , Repairs To Four Wheel And Brake System:- Labour Charges For Dismantling Of Four Wheel And Brake System With Repairs And Replacement Of Defective Parts With Providing/Fitting Of New Parts I.E. Front Wheel Bearing Inner-02 No, Front Wheel Bearing Outer-02 No., Front Wheel Oil Seal -02 No, Rear Wheel Inner/Outer-02 No. Each, Rear Wheel Oil Seal -02 NoS Each, Wheel Bearing Grease-05 Kg, Front Wheel Overhauling Kit-01 No. , Rear Wheel Overhauling Kit-02 No., Front Wheel Hub Nut/Bolts-04 NoS, Rear Wheel Hub Nut/Bolts-06 NoS, Rear Wheel Axle Joint-02 No. ,Rear Hub Nut/Bolts-04 No.,Tq Oil-01 Lit., Front/Rear Wheel Shoe Spring-02 No.,Rear Wheel Shoe Spring-03 No, Front Wheel Brake Lining With Rivets Rh/Lh Side -02 Set, Rear Wheel Brake Lining With Rivets Rh/Lh -02 Set, Ratchet/Slack Adjuster-04 No., Chuck Nut -02 Nos, Dhoti Cloth - 04 Kg Diesel For Washing -06 Ltrs, Refitting Of All Items And Resting Of All Wheels And Brake System And Testing. The Job Includes Cost Of Material And Labour Charges (Complete Job) , Repairs To Self: - Repairs To Self Of The Vehicle By Dismantling It, Cleaning And Testing Of Parts And The providing and Fixing Of Self Carbon Brush Set-01 Set, Field Coil -01 Set, Bendix Drive-01 No., Petrol For Cleaning Of Parts, Self Solenoid Switch-01 No., Voltage Regulator-01 No. Including Rewinding Of Armature. Testing And Fitting To The Vehicle. The Complete Job Include Cost Of Material And Labour Charges Complete Job , Servicing And Repair Of Air Conditioning System Of Vehicle No Jk02cu 2775 Tempo Trax Of Gmch Jammu. The Job Includes Complete Cleaning Of The Airconditioning Circuit And Replacement Of Damaged Compressor With New One And Filling Of Fresh Refrigerant Gas 1/2 Kg Of Same Specification. . The Complete Job Include Cost Of Material And Labour Charges Complete Job. Total In Figures 23 23 0.0 23 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
50.
Housing Urban and Rular Development #11259224 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division Gmch Jammu. Repairs Of Vehicles No Jk02dd 9279 Tempo Traveler Of Gmch Jammu. Mhdj/E-Nit 43 Of 2026-27 Dated: 13.05.2026 Due : 23.05.2026 Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate Including Gst To Be Quoted By The Bidder Rs. P Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Rebate On Old Parts In Percentage (%) If Any Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Net Cost Of Item Rs. P Total Amount Total Amount With Taxes Total Amount In Words , Replacement Of Pressure Plate Assembly Of The Tempo Traveler No Jk02dd 9279 The Job Includes Extracting The Damaged Pressure Plates From Its Installed Position And Fitting The New One As Per Sample. The Job Also Includes Replacement Of Fly Wheel By Providing And Fitting Of New One And Testing Its Functioning. The Complete Job Includes Cost Of Labour Charges, Material Charges, Carriage Charges And All Kind Of Taxes Therof. , Replacement To Clutch Assembly System Vehicle No Jk02dd 9279 Tempo Traveler :- Replacement Of Damaged Clutch Plate Assembly System With Of New One As Per Sample . The Job Includes Dismantling Of Damaged Clutch Plate Assembly From Its Installed Position And Fitting Of New One As Per The Sample Nd Testing Its Functioning. Complete Job Includes Cost Of Material & Labour Charges , Complete Servicing Of The Vehicle No Jk02dd 9279 Tempo Traveler Of Gmch Jammu. The Job Includes Replacement Of Engine Oil ,Gear Oil, Steering Oil,Coolant Along With Replacement Of Fuel Filter,Oil Filter, Air Filter And Air Conditioning Filter. The Job Include Servicing Of The Radiator By Removing It From Its Installed Position And Repairing Its Leakage By Brazing Method And Then Fitting It Back In Its Installed Position By Replacing Its Damaged The Rubber Hose. The Job Includes Servicing Of The Air Conditioner By Replacing The Defunct Valve And Recharging Of Refrigerant Gas And Allied Works. The Job Includes Complete Cleaning Of The Vehicle With Soapy Water To Remove All Traces Of Dust And Mud From The Inner Side And Outer Of The Vehicle And Applying Coat Of Protective Polish. The Job Includes Wheel Alignment And Wheel Balancing Of All The Tryes. Complete Job Includes The Cost Of Material And Labour Charges And All Taxes . , Repairs To Four Wheel And Brake System:- Labour Charges For Dismantling Of Four Wheel And Brake System With Repairs And Replacement Of Defective Parts With Providing/Fitting Of New Parts I.E. Front Wheel Bearing Inner-02 No, Front Wheel Bearing Outer-02 No., Front Wheel Oil Seal -02 No, Rear Wheel Inner/Outer-02 No. Each, Rear Wheel Oil Seal -02 NoS Each, Wheel Bearing Grease-05 Kg, Front Wheel Overhauling Kit-01 No. , Rear Wheel Overhauling Kit-02 No., Front Wheel Hub Nut/Bolts-04 NoS, Rear Wheel Hub Nut/Bolts-06 NoS, Rear Wheel Axle Joint-02 No. ,Rear Hub Nut/Bolts-04 No.,Tq Oil-01 Lit., Front/Rear Wheel Shoe Spring-02 No.,Rear Wheel Shoe Spring-03 No, Front Wheel Brake Lining With Rivets Rh/Lh Side -02 Set, Rear Wheel Brake Lining With Rivets Rh/Lh -02 Set, Ratchet/Slack Adjuster-04 No., Chuck Nut -02 Nos, Dhoti Cloth - 04 Kg Diesel For Washing -06 Ltrs, Refitting Of All Items And Resting Of All Wheels And Brake System And Testing. The Job Includes Cost Of Material And Labour Charges (Complete Job) , Repairs To Tie Rod & King Pin Assy. Dismantling, Extraction Of Worn-Out Parts And Replacement With providing and Fixing Of New Parts I.E. King Pin-02 No., King Pin Bush-04 No., King Pin Bearing-02 No., Arm Bolt-01 No., Spacer-02No., Shims-02 No., O-Ring -02 No., King Pin Lock-02 No., Tie Rod End L/H And R/H-01 Set, Tie Rod End Repair Kit-01 Kit, King Pin Repair Kit-01 No. Alignment Of Wheel And Checking. The Job Includes Cost Of Material And Labour Charges For Fitting And Checking. Complete Job , Repairs To Rear And Front Leaf Assy And Shockers By providing and Fixing Of New Parts In Place Of Defective/ Worn Out / Cracked Leafs Of Vehicle I.E. Leaf Spring Front R/H Side 3Rd-01 No., Leaf Spring Front L/H Side 5Th-01 No, Leaf Spring Front L/H Side Main-01 No., Leaf Spring Rear R/H Side 2Nd-01 No., Leaf Spring Rear L/H Side 4Th-01 No -Clamp Small-03 No., U-Clamp Large-04 No., Bush-04 No., Shackle Pin-04 No.,Centre Bolt-04 No. Clamp Top-02 No., Grease Nipple-04 No.,Tensioning ,Greasing And Assembling The Same. The Job Also Includes Repairs Of Shockers Including Change Of Oil,Seals, Washers Etc. Complete Job Includes Cost Of Material And Labour Charges (Complete Job) Total In Figures 23 23 0.0 23 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
TenderDetail
Loading tenders