View Bid Results For Reactor With Agitator Tenders

We found 29 Bid Results related to reactor with agitator tenders. You can find Contractor details who won reactor with agitator tenders along with contract details in Bid awards announcements section.

Filters
Stage
27
2
Tender Publishing Platform
13
16
State / UT
9
9
7
3
3
2
2
1
1
1
Contract Value
3
7
13
6
Publish Date
0
0
0
0
0
Sector
7
14
6
5
1
1
1
1
Ownership
4
15
9
4
1
Within keyword
Active filters:
Showing 1–1 of 29 tenders matching your filters
1.
Defence #9913771 AOC
Tender For Repair/Maintenance Of Dg Set, Solar Water Heater, Chlorine Plants, Lifts And Stps Under Ge (I) Kanpur.; 1 Servicing / maint of solar water heater system of capacity up to 750 ltr including dismantling the required parts after that de-scaling, cleaning of water tank, cleaning of pipe, air vent, eliminator etc and refixing the dismantled parts at its original position to make solar water heater functional by replacement of minor accessories and testing on completion complete all as specified and directed. Notes:- (i) Minor spares i.e nut, bolt, washers, wire or other minor parts if required shall deems to be included in this job. (ii) Any accessories found unserviceable that shall be replaced & paid under respective items of this Sch as supply only and cost of fixing of the same shall be deemed to included in this item. 2 Supply only PVC hose pipe for Solar water heating system including clamps, washers, bolts etc where ever reqd complete all as specified and directed. 3 Supply only of thermostat with connected fittings complete all as specified and directed. 4 Supply only of air vent valve complete all as specified and directed. 5 Supply only of drain valve complete all as specified and directed. 6 Supply only of shutt off valve complete all as specified and directed. 7 S&F 20 mm bore GI pipe medium grade ISI marked with all fittings and fixed to walls / roofs or laid in floors / plinth protection including making good disturbed surfaces with cement mortar (1:3) to match with existing surfaces complete all as specified and directed. 8 M&L High density polyethylene (HDPE) pipes of pressure rating 6 kgf/sqcm / Polypropylene Random Copolymer (PP-R) pipes with all fitting / fixture (for hot and cold water supply) fixure to wall / floor of 20 mm dia pipe complete all as specified and directed. 9 S&F 20 mm dia stop valve chromium plated cast copper alloy, fancy type high pressure with capstan head screwed both ends for iron / PP-R pipe or for union complete all as specified and directed. 10 S&F Solar Flat Plate Collector OF Selective Black chrome with Nickel Undercoat absorber, Italian design, (screw less construction for durability) Copper riser tube dia 12.5mm x 0.55mm thick, 9 risers, Copper header tube dia 25.4 mm x 0.72mm thk x 1120 mm length, Toughened glass 4mm thick transmittance up to 87%, Aluminum-PU coated frame, Box Type Structure body, Glass wool and Rock wool insulation, Back Insulation - 50mm thick, Side Insulation - 25mm thick, 48 Kg/Mtr cube insulation density, Stainless Steel - SS 304L, having 6 bar pressure complete all as specified and directed. 11 S&F in replacement of SS-304 pressurized tank 300 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. 12 S&F in replacement of SS-304 pressurized tank 500 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. 13 S&F in replacement of SS-304 pressurized tank 750 ltr and puff insulation 4 kg/sqcm working pressure with MS Stand complete all as specified and directed. 14 S&F in replacement of ETC tube size 58mm x 1800 mm solar water collector complete all as specified and directed. 15 S&F in replacement of ETC tube size 58mm x 2100 mm solar water collector complete all as specified and directed. 16 S&F in replacement of ETC Coupler flange set complete all as specified and directed. 17 S&F rotational moulded polyethylene water storage tanks, 250 capacity (cylindrical veryical with closed top) hoisted and fixed in position all as specified in SSR Part I, including MS stand of suitable size as per recommendations of solar water heater, including two coats of anticorrosive paint over and including a coat of anticorrosive primer complete all as specified and directed. 18 S&F in replacement of Mild steel framed/sheet work for tanks/panel/pump cage supported structure/ladder and similar works conforming to Fe-290 Gde-E-165 including welding/cutting of steel including painting of two coats of synthetic enamel paint over and including one coat of primer paint (incl preparation of surface) complete all as specified and directed. 19 S&F in replacement of change over switch on load 415 volt in sheet metal enclouser 4 pole of capacity 125 Amps incl disconnecting and dismantling old and fixing on wall making electric connection with existing cable complete all as specified and directed. 20 M&L for hot lagging and wrapping on GI / PP-R pipe used in internal plumping work all around with bonded mineral wool performed snap on pipe section of density 48 Kg / cum conforming to IS 9842 and covered with required size of glass wool and aluminium cladding of required size for up to 20 mm bore pipe complete all as specified and directed. 21 S&F heating element 1500/2000 watt capacity suitable for solar water heaterpush / screw type with O ring including making electrical connection complete all as specified and directed. 22 M&L for fixing glass wool insulation for Hot water pipe complete all as specified and directed. 23 S&F in replacement of air eliminator complete all as specified and directed. 24 Taking / liftingout defective submersible type raw sewagepumps set of capacity 1.1 KW/2760 RPM from raw sewage sump with column pipe steel rope, submersible cable and accessories, including cleaning, greasing , oiling of bearing of electric motor, impeller shaft and relowering the same after repairing works including replacement of worn out parts as per requirement and testing complete all as specified and directed. 25 M&L for rewinding of submersible type sewage motor 1.1 KW/2760 RPM with existing same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc.including cleaning and replacement of defective parts complete all as specified and directed. 26 Taking out defective Air blower with motor of capacity 3 KW/1400 RPM with all accessories, including cleaning, greasing,oiling of bearing of electric motor and refixing, including cleaning, greasing, oiling of bearing of electric motor, impeller shaft and commissioning the same after repairing works including replacement of bearing and testing complete all as specified and directed. 27 M&L for rewinding of Air blower motor of capacity 3 KW/1400 RPM with existing same type & gauge of winding wire as per motor capacity using new insulation material such as insulating paper sleeves etc.including cleaning and replacement of defective parts complete all as specified and directed. 28 Supply and replacement of air filter for air blower of capacity 3 KW as per existing pattern/make complete all as specified and directed. 29 Taking out defective Monoblock centrifugal pump set of capacity 5.5 KW/1500 RPM with all accessories including cleaning, greasing , oiling of bearing of electric motor and refixing the same after repairing works including replacement of worn out parts as per requirement and testing complete all as specified and directed. 30 Supply and fixing of Contactor Model No MNX-12 making proper connection with suitble lugs complete all as specified and directed. 31 S&F MCB SPN240 volts 40 Amp including connection with suitable size aluminium / copper lugs complete all as specified and directed. 32 M&L for earthing with GIplate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable and making test point and all connections complete all as specified and directed. 33 M&L for cleaning raw sewage chamber and cleaning all foreign Materials complete all as specified and directed. 34 M&L for draining out sewage water from Fludized Aerobic Bed (FAB) reactor and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. 35 M&L for drain out sewage water from Tube settler tank and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. 36 M&L for drain out sewage water from treated watertank and cleaning and washing the same and inlet /outlet pipes complete all as specified and directed. 37 M&L for cleaning of bushes shrubs, grass around out side of STP upto 2 meter between fencing & road complete all as specified and directed. Note : Necessary tools for cleaning will be arranged by the contractor with out any extra cost. 38 M&L for plastic filter media for enhancedbacterial development in filter tank used in STP plant complete all as specified and directed. 39 Removing of dried sludge from sludge drying bed and depositing the same at a distance of not less than 200 mtr from plant complete all as specified and directed. 40 Supply and replacement of butter fly valve of size 50 mm bore ISI marked heavy duty including suitable nut,bolt & washer complete all as specified and directed. 41 Supply and filling of oil ENKLO 320 or equivalentfor air blower of capacity 3 KW complete all as specified and directed. 42 Supply& Pouring sodium hypo chloride ( Chloine percentage 10-11%) in treated sewage water in manufacturer standard packing complete all as specified and directed. 43 M&L for testing of treated water of STP (Monthly) from any NABL approved laboratory and submit the report timely complete all as specified and directed. 44 M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework and all the articles shall be painted with synthetic enamel paint over and including a coat of red oxide complete all as specified and directed. 45 M&L for painting of steel and iron surfaces with one coat of synthetic enemelled paint after preparation of old painted surfaces of STP 100 KLD capacity of STP complete all as specified and directed. Note:- Bidder are advised to visit the site before quoting the tender to find out actual qty of painting. 46 Minor repair/cleaning/servicing/maintenance and testing of chlorine granuals based dosing plant comprising of dosing pump, agitator and FRP tank and connected pipe lines etc once in a week complete all as specified and directed:- Note : (a) Testing of chlorine at consumer end with medical authority and maintained chlorine test record once a week on a register and submit report to concern JE E&M/Engr-in-Charge.(b) Servicing of Agitator of by using necessary lubricant, replacement of bush/bearing, alingning the shaft , key etc. deemed to be included in item rate.(c)Any other spares required for replacement shall be supplied and fixed under relevent item of Sch A. (d) If any defect found in plant contractor should rectify the defect with in 24 Hrs, if failed to rectify the decfectthe contractor shall be liable to pay compensation Rs 500/- (Rupees five hundred only) per plant per day. 47 S&F in replacement of Motor 230 volt, 50 Hz, voltage input 230 volt single phase 50 Hz, current consumption 0.4 Ampr power 120 watt, speed 4 pole induction non synchronous 920 RPM Approx under lead motor shaft dia 15mm X Length 50 mm motor is flange mounted 4 no of 7 mm dia hole at PCD 150 mm incl all fixing arrangement complete all as specified and directed. 48 S&F in replacement of shaft with impeller made out of MOC poly propelene rigid dia 32 mm X Length 500 mm impeller type two bladed pitched blade turbine numbar of impeller- I incl all fixing arrangements complete all as specified and directed. 49 S&F in replacement of Dosing tank only capacity 100 Ltrs MOC PE FRP Ltd contaning port hole for pouring chlorination chemical and water them necessary provision for mounting of moter at proper angel provision for mounting dosing pump on lid level gauge complete all as specified and directed. 50 S&F in replacement of Rotor assembly with bearing brackets & tolerance ring complete all as specified and directed. 51 S&F in replacement of Single head feet rate control with shaft complete all as specified and directed. 52 S&F in replacement of Pump head (ferrules 1/4 & duchbill included) complete all as specified and directed. 53 S&F in replacement of Pump tube complete all as specified and directed. 54 S&F in replacement of Injection check valve complete all as specified and directed. 55 S&F in replacement of Weighted suction line strainer 3/8 complete all as specified and directed. 56 S&F in replacement of 3/8 white suction/discharge tubing complete all as specified and directed. 57 S&F in replacement of Check valve duckbill only (PK-5) complete all as specified and directed. 58 S&F in replacement of Gear motor complete 230 volt 50 Hz complete all as specified and directed. 59 S&F in replacement of Coil 250 volt 50 Hz complete all as specified and directed. 60 S&F in replacement of Roller Assembly complete all as specified and directed. 61 S&F in replacement of dosing pump (Model No 96 NGQ 51) high pressure single head geared motor adustable dosing having output upto 40 US GPD and pressure upto 7 kg/cm2 with connecing accessories complete all as specified and directed. 62 Supply & Pouring Calcium based high strenght granular chlorination chemical having 65 % to 70 % active chlorine, whitish, free flowing, decomposes clear in water solution, free of foriegn matter , the chlorination chemical should contain appropriate quantities of dispersants, corossion inhibitors to prevent incrustation scaling in distribution systems, mercury and other heavy meatl conteminents in chlorination chemical must be Below Detectable Limit (BDL) complete all as specified and directed. 63 Repair/servicing to DG set any make/modal 50/62.5/83 KVA water cooled diesel engine by taking out dismantling segregation of all parts and re-assembling after duly repair/ replacement of following new part fixing including all type machine work such as turning reaming etc, washing, cleaning, greasing , wires, replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site complete all as specified and directed. Note:- Any other accessories found unserviceable that shall be replaced & paid under respective items of this Sch as supply only and cost of fixing for fixing of the same shall be deemded to included in the quotd rate under this item. 64 All as per item No 63.00 above but for DG Set of capacity 15-20 KVA in Cantt area complete all as specified and directed. 65 Supply only Lub oil filter element for 50/62.5/83 KVA DG Set complete all as specified and directed. 66 Supply only Lub oil filter element for 15- 20 KVA DG Set complete all as specified and directed. 67 Supply only Fuel filter element for 50/62.5/83 KVA DG Set complete all as specified and directed. 68 Supply only of Fuel filter element for 15/20 KVA DG Set complete all as specified and directed. 69 Supply only of Dry type air cleaner for 50/62.5/83 KVA DG Set complete all as specified and directed. 70 Supply only of Dry type air cleaner for 15/20 KVA DG Set complete all as specified and directed. 71 Supply only of V-Belt of fan for 20 to 83 KVA DG Set complete all as specified and directed. 72 Supply only of manual type Governor Assy for 50/62.5/83 KVA DG Set complete all as specified and directed. 73 Supply only of manual type Governor Assy for 15/20 KVA DG Set complete all as specified and directed. 74 Supply only of Starting switch of DG set up to cap 50 to 83 KVA complete all as specified and directed. 75 Supply only of Starting switch of DG set up to cap 20 KVA complete all as specified and directed. 76 M&L for replacement of complete wiring (copper multistrand cable) of DG set any capacity as directed at site including thimble screw and sleaves etc complete all as specified and directed. 77 Supply only of Gauge lube oil pressure of DG set cap 20 to 83 KVA complete all as specified and directed. 78 Supply only of Hose pipe for of DG set cap 20 to 62.5 KVA complete all as specified and directed. 79 Supply only of radiator hose pipe of DG set cap 20 to 83 KVA complete all as specified and directed. 80 Supply only of Injector assy of DG set cap 50 to 83 KVA complete all as specified and directed. 81 Supply only of Injector assy of DG set cap 20 KVA complete all as specified and directed. 82 Supply only of Clamp hose radiator of DG set complete all as specified and directed. 83 Supply only of water body of DG set 50/62.5/83 KVA complete all as specified and directed. 84 Supply only of Turbo charging kit assembly of DG set 50 to 83 KVA complete all as specified and directed. 85 Supply only of self starter 12/24 volt for DG set 50 to 83 KVA complete all as specified and directed. 86 Supply only of AVR (Anti Voltage Regulator) for DG Set of capacity 50 to 83 KVA complete all as specified and directed. 87 Supply only of AVR (Anti Voltage Regulator) for DG Set of capacity 20 KVA complete all as specified and directed. 88 Supply only of Rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24 /12 V DC full wave rectifier unit for DG set 50 to 83 KVA as site requirment complete all as specified and directed. 89 S&F in replacement of Rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24 /12 V DC full wave rectifier unit for DG set 20 KVA as site requirment complete all as specified and directed. 90 S&F in Repair/Replacement of Control Panelfactory made indoor type control cubical made out of 1.6mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 62.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs 100 A and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc complete all as specified and directed. 91 M&L for Repair of Control Panel (50-62.5 KVA DG set)for replacing of U/S relay,andall internal wiring including lug,thimble switches with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 3/4 pole MCCBs 100 A and Contactors of capacity as recommended by the manufacturer , detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc complete all as specified and directed. 92 Repair of(In line) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, celebration for DG set of capacity 50 to 83 KVA & testing on completion complete all as specified and directed. 93 Repair of(In line) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, celebration for DG set of capacity 15 to 20 KVA & testing on completion complete all as specified and directed. 94 Repair to radiator assy Cleaning washing throughly, descaling and M&L for replacement of rubber size paid and MS Nut & Bolts including brazing /repair of cooling tubeswith dismantling and segregation upper and lower chamber (tank) includingand reassembling complete incl nut, bolt, washers, & spring any type for DG set capacity 20 to 83 KVA complete all as specified and directed. 95 Cleaning decarbonishing and spray painting to DG Set canopy outside of capacity 20 KVA to 62.5 KVA including writing SM No, Srl No, Make, capacity & date of installation complete all as specified and directed. 96 Disconnecting, dismantling & repair to Dynamo with segregation of all parts supply and fix in replacement of armature field, coil, carbon brush and bearing etc reassembling complete & testing on completion complete all as specified and directed. 97 Supply and fixing in replacement of maintenance free battery 12 volt 180 AH 25 plate including battery leads and initial charging of battery complete all as specified and directed. 98 M&L for replacement of Coolant for DG set complete all as specified and directed. 99 M&L for replacement of Engine oil 20 W 40 complete all as specified and directed. 100 Supply and fix in replacement engine Hrs run meter digital type suitable to match with existing system of DG set complete all as specified and directed. 101 Supply and fixing in replacement of maintenance free battery 12 volt 150 AH 25 plate including battery leads and initial charging of battery complete all as specified and directed. 102 Disconnecting, dismantling and repair/servicing to self starter 12/24 volt and replacement of field coil, carbon brush, bush or other unserviceable parts parts and refixing and testing after completion complete all as specified and directed. 103 M&L in replacement of microprocessor digital type DG set controller of DG set capcity 50 KVA to 62.5 KVA (Make of DG set- Greaves Cotton) including connect all control wiring& programming all the parameter related to DG set at site complete all as specified and directed. 104 M&L in replacement of microprocessor digital type DG set controller of DG set capcity 15 to 20 KVA(Make of DG set- Greaves Cotton) including connect all control wiring& programming all the parameter related to DG set at site complete all as specified and directed. 105 S&F in replacement of Automaticbattery chargerAC input 230 + 10% V output DC for 12/24 volt battery current 10-15 Amp for 01 No battery at a time with digital ammeter and voltmeter complete all as specified and directed. 106 S&Fin replacement ofBattery terminal of Copper bolt type suitable for any tpe of battery complete all as specified and directed. 107 S&Fin replacement ofBattery lead of copper conductor 35 Sqmm single core fitted with suitable terminal on both side complete all as specified and directed. 108 M&L for winding of armature winding and field windingwith super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc for alternator ofDG set of capacity 50 to 83 KVA incl taking out the old burnt windings complete all as specified and directed. 109 M&L for winding of armature winding and field windingwith super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc for alternator ofDG set of capacity 15-20 KVA incl taking out the old burnt windings complete all as specified and directed. 110 M&L in replacement of flame proof asbestos rope of specified dia wrapped around the exhaust pipe complete all as specified and directed. 111 Supply poring of distilled water for maint of battries complete all as specified and directed. 112 S&F in repair MCCB 4 Pole, 415 V, Adjustable type 160 amps with breaking capacity 25 KA complete all as specified & directed. 113 S&F in repair MCCB 4 Pole, 415 V, Adjustable type 250 amps with breaking capacity 25 KA complete all as specified & directed. 114 Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps complete all as specified and directed. 115 M&L for PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3 core complete all as specified and directed. 116 Repair/servicing to Retrofit Emmision Controll Device any make/modal 62.5 KVA DG Set taking out dismantling segregation of all parts and re-assembling after duly repair work such as structure, Sensor, Automation, operational & panel checks, Pneumatic Cleaning of filters & all type nuts bolts washers & other minor parts as required at site and testing on completion at site complete all as specified and directed. Note:-1) This servicing is carried out by authorised OEM Chakr innovation Private Limited. 2) NABL (National Accreditation Board of Testing and Calibration Laboratories) Testing. 117 Comprehensive maintenance of following lifts in Adm buildings COD Kanpur including checking, repairing, replacing the defective items if any, preventive maintenance, greasing, lubracating, providing necessary item reqd for up keeping the lift in working condition as per OEM recommandation complete all as specified and directed. (a) Passanger Lift (8 Passenger) Machine No- J009009 Installed at Adm block, COD KanpurMake- OTIS elevator Co (I) Ltd. (b)Passanger Lift (13 Passenger) Machine No- J009254 Installed at Adm block, COD KanpurMake- OTIS elevator Co (I) Ltd. NOTE- (i) All repair / Maint to be carried out by OEM /authorised rep of OEM. Minimum two visit in one months with OEM Rep if emergency any time called for repair. Bidder shall enter an MoU with OEM of lift for repair/services of this item. The MoU with OEM shall be submitted immediately after issue of work order/commencement of work. Non submission of MoU with OEM shall lead to cancellation of contract. (ii) Repair/maint of the lift will carried out by skilled/trained personnel under the OEM supervision. (iii) Examine peroidically all safety devices and governors of the lifts and make all customary safety tests. (iv) The necessary T&P reqd shall be arranged by the OEM/Contractor and cost of the same shall deemed to be included in the rate quoted items will be paid and measured separetly as supply only. 118 Supply only J relay OTIS Make complete all as specified & directed. 119 Supply only attached panel for OTIS Make complete all as specified & directed. 120 Supply only Transformer for OTIS Make complete all as specified & directed. 121 Supply only Choke for OTIS Make complete all as specified & directed. 122 Supply only Shaft for OTIS Make complete all as specified & directed. 123 Supply only Shaft Bearing for OTIS Make complete all as specified & directed. 124 Supply only Door Motor for OTIS Make complete all as specified & directed. 125 Supply only Gate Roller for OTIS Make complete all as specified & directed.
Contract Date: Feb 28, 2026 Contract Value : 34.55 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 10.20 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
4.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
5.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
6.
Public Administrative Department #9347251 Technical Bid
Annual Rate Contract For Material And Annual Maintance Work For Water Supply Department For Murbad Nagar Panchayat Lt Cables,And Pannels,Vtpumps,Hsc Pump,Spairs,Dgspair,Wall Spaires Etc , Part A - Civil Work , Earthing And Gi Strip , Maintenance Free Earthing , Gi Strip , Copper Earthing Strip , Lt Panel , Single Polemcb 6A , Voltmeter Selector Switch , Ammeter Selector , 200 A Mccb 4P , 200 A Mccb 3P , Ct400/5A Cl1,5Va , Ct200/5A Cl1,5Va , Spreader Link200 A , Spreader Link400 A , 400Amccb,4P,37Ka, Tm , R- Phase 240V , Y- Phase 240V , B- Phase 240V , Changeover Switch 200A , Mcb 2P, 16 Amps , Mcb 2P, 25 Amps , Digital Ammeter,1Ph (96X96) , Mcb 2P, 40 Amps , Mcb 2P, 63 Amps , Digital Voltmeter (96X96) , Overload Relay , Extended Rotary Handel400a , Extended Rotary Handel200a , Extended Rotary Handel200a , Fuse Link 32A , 63A Sfu,3P, 25Ka , Fuse Link 63A , 100A Sfu,3P, 25Ka , Fuse Link 100A , Fuse Link 200A , 200A Sfu,3P, 25Ka , Contactor 18 Amps, Coil 240 V , Contactor 50 Amps, Coil 240 V , Contactor 40 Amps, Coil 240 V , Contactor 32 Amps, Coil 240 V , Contactor 25 Amps, Coil 240 V , Contactor 12 Amps, Coil 240 V , Contactor 200 Amps, Coil 240 V , Contactor 115 Amps, Coil 240 V , Contactor 70 Amps, Coil 240 V , On Delay Timer , On/Off Delay Timer , D3 Dmprr1 , Ct For Mprd2 , F3 Vsr 4 , Auxlllary Contactor 240V Coil, 1 Nos+ 3Nc , Rubber Matting , Fire Extiguisher , Capacitor,525 V , 7% Detunned Reactor , Apfc Relay , Lt Cables , 1Core X 400Sqmm, Al, Armoured Cable , 3Core X 16 Sqmm, Al, Armoured Cable , 3.5Core X 120Sqmm Al Armoured Cable , 3.5Core X 95 Sqmm Al Armoured Cable , 3.5Core X 150Sqmmal Armoured Cable , 3.5Core X 180Sqmm Al Armoured Cable , 3.5Core X 70Sqmm Al Armoured Cable , 3.5Core X 50Sqmm Al Armoured Cable , 3.5Core X 25Sqmm Al Armoured Cable , 4Core X 16Sqmm Al Armoured Cable , 4Core X 4Sqmm Armoured Copper, Cable , Crane Hire Charges For Loading And Unloading , 300 Mm , Pn1, Nrv , 250 Mm , Pn1, Nrv , 50 Mm , Pn1, Sluice Valve , 80 Mm , Pn1, Sluice Valve , 200 Mm , Pn1, Sluice Valve , 250 Mm , Pn1, Sluice Valve , 300 Mm , Pn1, Sluice Valve , Air Valve 50 Mm , Air Valve 80 Mm , Wtp Work , Chemical Washing Of Filter Media. , Providing And Filling Of Filter Media Pebbles , Providing And Filling Of Filter Media Sand , Removing Of Filter Media , Dismentling Of Old Scrapped Flash Mixer Agitator Assembly With Its Gear Box And Motor , Providing And Fixing New Bellmouth And Bird Cage In Ss 304 Grade 1200 Mm. Id On Lip Of Aeration Fountain. , Replace New Flash Mixer With Agitator As Per Standard Specification Including S.S. Shaft, Suitable Reduction Gear Box , Suitable Size Motor .1440 Rpm,Etc. Complete. , Providing And Fixing M.S. Mechanical Flocculatar Assembly With S.S. Shaft, N.P.P.Blades And Arms, Pedestal Bearing, Reduction Gear Box 3 Hp , Providing And Fixing New Central Mechanism Assembly Including Sleepering Unit (Current Collector) With Copper Carbon Brushes Necessary Armored Cable, , Scrapper Mechanism – Rubber Squizer 12 Mm. Thk. Neoprin Make – , Providing And Fixing End Carrage Assembly With S.S. Shaft,Pedestal Bearing, Reduction Gear Box In Suitable Size, Motor Of Suitable Hp. 1440 Rpm, Tefc With Pu Wheels, Coupling, Baseframe And Foundation, Epoxy Paint Triple Coated Etc. Complete. , Supplying And Erecting Iron, Sheet Metal Work Consisting Of Crca Sheets, Various Sections Of Iron, Plates, Chequered Plates, Rods, Bars, Ms Pipes, Etc. , Supplying And Erecting Integrated Led Street Light Fitting 100-110W , Excavation For Foundation In Earth, Soil Of All Types, Sand, Gravel And Soft Murum, , Pcc Providing And Laying Cast In Situ/Ready Mix Cement Concrete In M15 Of Trap/Granite/Quartzite/ Gneiss Metal For Bed Blocks, Foundation Blocks And Such Other Tems , Providing And Laying Cast In Situ/Ready Mix Cement Concrete M-25 Of Trap/Granite/ Quartzite/ Gneiss Metal For R.C.C. , Providing, Fabricating, Erecting , Testing & Commissioning Of M.S. Pipe, Specials, Flanges Duly Painted Etc. Complete. , Providing Loss Of Head Indicators Including Plain Glass Tubes, Needles, S.S. Counter Weight, Flotter, Measuring Scale Etc. Complete , Vt Pump Spares , Removing, Dismantling And Assembling Of 75 Hp Vt Pump And 50 Hp Hsc Pump. , Pipe Plug , Brg Suction , Bowl Wearing Ring , Impeller Wearing Ring , Suction Bell , Bowl Bush , Inter Bowl , Impeller , Impeller Lock Collet , Disc Case Bearing , Discharge Case , Pump Shaft , Pump Shaft Coupling , Flgd Col Pipe (Bottom) , Line Shaft (Bottom) , Line Shaft Sleeve , Line Shaft Brg , Brg Retainer , Line Shaft Coupling , Flgd Tof Col Pipe , Sol Plate , Top Shaft Slleev , Packing Box , Packing Box Bush , Spring Loaded Greease Cup Assembly , Water Seal Ring , Packing Gland , Thurst Bearing Assembly , Top Shaft , Cooling Assembly , Packing , Strainer , Line Shaft , Rubber Bush , Mounting Cover (Ratchet Plate) , Oil Retainer Sleeve , Pressure Guage , Hsc Pump Spares , Impleller , Pump Shaft , Wear Ring , Shoulder Ring , Split Gland , Lantern Ring , Liquid Deflector , Bearing Housing De , Bearing Housing Nde , Deep Groove Ball Bearing , Shaft Sleeve , Key For Impeller , Key For Coupling , Gland Packing , Grease Nippel For Bearing , Grease Nippel For Sealing , Vent Valve , Oil Seal , Dg Spares , Radiator Pre-Mix Greaves Kool , Greaves Lub Oil , L.O.Fltr+Element V8/V6 , Filt. Element With O Ring , Servicing Of Dg , Lit(Full Replacement) , Greaves Lub Oil 10Ltr , Lub Oil Filter(232V12) , Outer Element , Inner Element , V Belt Ax-66 Cogged , Ax-45-Cogged Belt , Cogged Belt Ax-40 , Set Of Hoses Tbd3v8rc , Electrical Items , 75 Hp Ats , 50 Hp Ats , Transportation Of Transformer Without Loading And Unloading , Transformer Oil Filtration Per Ltr , Inspection Of Faulty Transformer , Dismentalling Of Existing Transformer , Supply And Topping Up Of Filtered Transformer Oil , Re-Erection Of Transformer , Overhauling Of Transformer , Rewinding Of Transformer 100 Kva , Supply And Topping Up Of Silica Gel , Provide And Fitting Ht Bushing Of 100 Kva Transformer , Provide And Fitting Lt Bushing Of 100 Kva Transformer , God, 200 Amps , Do, 15 Amps , Lightning Arrester , Pin Type Insulator , Disk Type Insulator , Acsr Conductor Dog Type , Operating Rod , Motor , Removing, Dismantling And Assembling Of 75 Hp Motor , Removing, Dismantling And Assembling Of 50 Hp Motor , Overhauling Of 75 Hp Motor , Rewinding Of 75 Hp Motor , Overhauling Of 50 Hp Motor , Rewinding Of 50 Hp Motor , Replacement Of Cooling Fan , Painting Of 75 Hp Motor , Painting Of 50 Hp Motor , Metalizing Of Top & Bottom End Cover Of Vss Motor For Fixing Of Bearings Satisfactory. 75 Hp , Metalizing Of Top & Bottom End Cover Of Vss Motor For Fixing Of Bearings Satisfactory. 50 Hp , Valve Spares , Valve Stem, Ss , Valve Stem Nut , O Ring Bush , Valve Gate , Door/Disc , Removing & Dismantling Of Sluice Valve From Pipe Line , Labour Charges For Replacement Of Sluice Valve Gland, S.S. Spindle, Stem & Nut , Labour Charges For Replacement Of Sluice Valve Wedge, Wedge Facing Ring, Body Face Ring, Blank Plate, Spindle, Sealing Ring Etc , Hinge Pin , Body Disc Ring , Disc Facing Ring , Lifting Equipments , Chain Pulley Block, 3Ton , Travelling Trolley
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 23.88 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Madhya Pradesh View Result →
11.
Petroleum and Natural Gas #6083601 AOC
Bids Are Invited For 1 Removal Of Existing Vfd Panel ( Fhm-330, 331A&B, 332A&B, 351A&B And 370 ) 2 Installation Of New Vfd Panel ( Fhm-330, 331A&B, 332A&B, 351A&B And 370 ) , Power& Control Cable , Earthing Works Etc 3 Installation Of 2X10kva Ups, Acdb And Battery Bank And Related Power &Control Cable And Earthing Work Etc 4 Installation Of New Dcdb And Related Power &Control Cable And Earthing Work Etc 5 Removal Of Existing Ss#39 Dcdb 6 Installation Of 415 V L&T Pcc Extension Panel 7 Installation Of 6.6Kv / 415V 400Kva Dry Type Transformer , 415V G150 Vfd And 415V Lt Change Over Panel For Paletizer Stand By Vfd And Related Power & Control Cable And Earthing Work Etc 8 Installation Of 6.6Kv Ht Change Over Panel For Reactor Agitator Vfd And Related Power, Control & Earthing Etc Works. And Related Power & Control Cable And Earthing Work Etc 9 Removal Of Running Extruder Vfd 33Kv / 2X1.7Kv 10.5Mva Transformer And Installation Of Spare Transformer 10 Disconnection And Termination Of Power, Control And Earthing Cables Of Extruder Motor 11 Disconnection And Termination Of Power, Control And Earthing Cables Of Cg Compressor Motor. 12 Removal, Relocation And Installation Of Extruder Vfd Ups 13 Additional N2 Heater Control Panel Installation And Related Power & Control Cable And Earthing Work Etc 14 Dcs Control Cable Replacement Of All Vfds In Ss#39 ( Control Cable From Ss#39 Mtb-01& Mtb-02 To Srr#39 ) , Cable Laying, Disconnection, Termination Etc 15 Removal, Relocation And Installation Of Gbm-310&320 Vfd For Making Space For 2X10kva Ups 16 Replacing The Control Cable Of Ppu Plant Critical Drives Fhm-330, 331A&B, 332A&B Vfd Panel To Lcs Control & Indication.
Contract Date: Ref. Documents Contract Value : 26.41 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 2.94 Lakh
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : 22.23 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
16.
Petroleum and Natural Gas #4212621 AOC
Bids Are Invited For Operation And Maintenance Of Other Machines And Plants -Complete System, MECHANICAL OPERATION AND MAINTENACNE CONTRACT AT IOCL, GREASE PLANT VASHI FOR TWO YEARS, REACTORS: (2 Nos.) Visual inspection for any leakage etc. and repairing the same. Changing of nuts, bolts & gaskets of manhole as and when required. Topping up lubricating oil in the lube oil pump of reactor agitator. Monitoring the pressure in the nitrogen cylinder of mechanical seal and reporting the same. KETTLES AND PRESSURE KETTLES: (9 Nos.) Daily cleaning of Kettle bottom strainers/jali before start of processing activity and as & when required during the shift operation. Visual inspection for any leakage etc. and repairing the same. Changing/topping up of lubricating oil into gear box as & when required. HOMOGENISERS: (5 Nos.) Visual inspection for any leakage etc. and repairing the same. Replacement/topping up of lubricating oils, changing the strainer of homogenizer. PUMPS (GEAR, TRIPLE SCREW & WATER): (60 Nos. approx.) Visual inspection for any leakage, etc. and repairing the same. Replacement/fitting of/gland packing etc. as and when required. Replacement/topping up of lubricating oils as and when required. Checking & tightening of foundation bolts, coupling guard, coupling alignment etc. OIL SKIMMERS: (2 Nos.) To operate both the oil skimmers in the shift if required. To raise the required level by filling water, To dispose of collected oil as advised by IOC Officer. To maintain skimmers in good conditions & keep the daily checking & operation record., INDUSTRIAL LIFT & HOISTS: (2 Nos.) Visual inspection for any damage in wire rope, pulley etc. and repairing the same. Replacement/topping up of lubricating oils as and when required. SMALL CAN FILLING SYSTEM: (1 Set) Replacement/topping up of lubricating oils as and when required. Changing the parts for filling of required sizes as and when required. Small can machine filling nozzle tightening. Also includes adjusting the nozzle to fill 20L/25L/50L COMPRESSORS: (2 Nos.) Visual inspection for any leakage, foundation bolts, etc. and repairing the same. Replacement/topping up of lubricating oils as and when required. Changing of V belts as and when required. BOILERS: (2 Nos.) Visual inspection for any steam leakage etc. from flange joints and repairing the same. FURNACES: (2 Nos.) Visual inspection for any leakages etc. and repairing the same. Checking of any abnormal condition as per operation & maintenance manual of the Furnace and rectifying the same. PIPELINES: Check leakage from flange joints and tighten/repairing the same, if found leaky. It includes welding patch work or small piece work. Only plates or pipes will be provided by IOCL. Starting the motor and filling the water tanks located in canteen, workers changing room, S&D building, DGM and Admin building and TITEX Plant. VALVES: (70 Nos. approx.) Greasing of valve stem. Check hand wheels / wheel nuts in position. Check leakage from drain and vent valves, glands and repairing the same as and when required. REACTORS CUM KETLES: (2Nos.) Visual inspection for any leakage etc. and repairing the same. Changing of nuts, bolts & gaskets of manhole as and when required., Topping up of lubricating oil in the lube oil pump and gearbox assembly of reactor agitator., LDO - Receipt LDO in Tanks & taking daily dip & maintain record. Top up LDO in Furnace & Boiler Fuel tanks daily & maintain the records., Lube Oils Receipt of Lube Oils. Topping up of lube oils in equipment and taking inventory. Oil/Air/water/grease Filter and strainers opening, cleaning & refitting Ball Valve/NRV/Flange/Spool piece removal, gasket replacement & refitting. Water/oil/air Hose fixing INCLUDES BOTH SIDE FIXING SHANK/FLANGE JOIINT/cam lock coupling Motor removal & refitting with proper alignment. Pump removal, servicing (checking bearing & mech. seals & replacing if necessary), refitting Pump/motor coupling removal, refitting. Flange/love joy/flexible coupling. Pump/motor removal from site & loading/unloading for shifting to workshop (if breakdown) or vice- versa Manhole opening & refitting with gasket replacement, cutting the gasket and fixing. Oiling/greasing/ oil top up of pumps/any equipment and removing old oil Barrel Filling Machine Air cylinder removal/servicing/refitting and repairing. Cleaning of strainer of Tanks and refitting with 200 Mesh jali. Mechanical jobs to be carried out at Plant during TT loading unloading operation. Working on Holiday, Sunday & Night Shift as per requirement or breakdown maintenance for skilled mechanic. Working on Holiday, Sunday & Night Shift as per requirement or breakdown maintenance for unskilled manpower Kettle Exhaust Duct Jali Cleaning During maintenance if any welding/gas cutting etc. is required to be done the same will be done and IOCL will provide electricity and water free of cost. The consumable materials for welding and gas cutting and welding machine will be arranged by the contractor. Product Hoses testing (4 nos.) with submission of test reports. Half yearly. Carry out change over in Auto pack filling machine from one package to another as and when required which includes, replacing all change parts required (change parts are supplied by IOC and are available at Plant), re-setting position of all components to suit the new pack to be filled, testing, and stabilizing for filling. Homogenizer operation Maintain logbook (PM/PDM) of Reactors, Kettles, Homogenizers and Pumps. All the workers to be present at the time of various audits/inspection for miscellaneous activities and aiding IOCL officers and auditors (internal as well as external). Total Quantity :
Contract Date: Ref. Documents Contract Value : 90.60 Lakh
Boards / Undertakings / PSU No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 51.50 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 1
18.
Chemicals and Fertilizers #2697888 AOC
Annual Rate Contract For Supply Of Gland Packing General At Rcf Trombay Unit. Annual Rate Contract For Supply Of Gland Packing General At Rcf Trombay Unit. , Gland Packing A) Type: Graphited Ptfe Yarn Packing In Interlock BraidingB) Size: 6 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: Upto 300°C2) Pressure: 150 Bar (Centrifugal Pump) / 125 Bar (Reciprocating Pump)/ 300 Bar (Valve) 3) Ph Range: 0-14 D) Applications:Pumps & Valves Handlingacid, Alkalies, Organic Chemicals, Condensate, Dm Water, Hydrocarbons, Thermic Fluids, Etc. E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style ‘Na 758Hspl.’ / James Walker Inmarco Style 504 / Champion Style 63 / Uniklinger Style 49 / Teadit Style 2007 / Pilot Gasket Style 2140 / Eagleburgmann StyleThermoflon Tr 6232 / Garlok Style5100 Gfo / Spitmann Style 36 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf. 2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: Graphited Ptfe Yarn Packing In Interlock BraidingB) Size: 8 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: Upto 300°C2) Pressure: 150 Bar (Centrifugal Pump) / 125 Bar (Reciprocating Pump)/ 300 Bar (Valve) 3) Ph Range: 0-14 D) Applications:Pumps & Valves Handlingacid, Alkalies, Organic Chemicals, Condensate, Dm Water, Hydrocarbons, Thermic Fluids, Etc. E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style ‘Na 758Hspl.’ / James Walker Inmarco Style 504 / Champion Style 63 / Uniklinger Style 49 / Teadit Style 2007 / Pilot Gasket Style 2140 / Eagleburgmann StyleThermoflon Tr 6232 / Spitmann Style 36 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: Graphited Ptfe Yarn Packing In Interlock BraidingB) Size: 10 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: Upto 300°C2) Pressure: 150 Bar (Centrifugal Pump) / 125 Bar (Reciprocating Pump)/ 300 Bar (Valve) 3) Ph Range: 0-14 D) Applications:Pumps & Valves Handlingacid, Alkalies, Organic Chemicals, Condensate, Dm Water, Hydrocarbons, Thermic Fluids, Etc. E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style ‘Na 758Hspl.’ / James Walker Inmarco Style 504 / Champion Style 63 / Uniklinger Style 49 / Teadit Style 2007 / Pilot Gasket Style 2140 / Eagleburgmann StyleThermoflon Tr 6232 / Garlok Style5100 Gfo / Spitmann Style 36 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: Graphited Ptfe Yarn Packing In Interlock BraidingB) Size: 12 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: Upto 300°C2) Pressure: 150 Bar (Centrifugal Pump) / 125 Bar (Reciprocating Pump)/ 300 Bar (Valve) 3) Ph Range: 0-14 D) Applications:Pumps & Valves Handlingacid, Alkalies, Organic Chemicals, Condensate, Dm Water, Hydrocarbons, Thermic Fluids, Etc. E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style ‘Na 758Hspl.’ / James Walker Inmarco Style 504 / Champion Style 63 / Uniklinger Style 49 / Teadit Style 2007 / Pilot Gasket Style 2140 / Eagleburgmann StyleThermoflon Tr 6232 / Garlok Style5100 Gfo / Spitmann Style 36 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: Dense Braided Packing Having Pure Aramid Fibres Corners With Pure Ptfe Fibres At The Running Surface And High Tensile Core Of Extruded & Expanded Ptfe Cord. B) Size: 8 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 500 Bar (Static) / 150 Bar (Rotary)/ 500 Bar (Reciprocating) 3) Ph Range: 1-13 D) Applications:Pumps & Valves Handling Ammonia, Urea & Carbamate Condensate, Amide, Hydrazine, Tri-Sodium Phosphate, Water, Dilute Acids & Alkalis, EtcE) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 745 Spl / James Walker Inmarco Style 105 Sut / Champion Style 172 / Uniklinger Style 25 / Teadit Style 2003 / Pilot Gasket Style 2160 / Eagleburgmann StyleSpezial-Kombi K1 6430/K1 / Garlock Style 5200 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Ready Cut Gland Packing A) Type: Dense Braided Packing Having Pure Aramid Fibres Corners With Pure Ptfe Fibres At The Running Surface And High Tensile Core Of Extruded & Expanded Ptfe Cord. B) Size (Readycut): 25 Mm Od X 13 Mm Id X 12 Mm C/SC) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 500 Bar (Static) / 150 Bar (Rotary)/ 500 Bar (Reciprocating) 3) Ph Range: 1-13 D) Applications:Pumps & Valves Handling Ammonia, Urea & Carbamate Condensate, Amide, Hydrazine, Tri-Sodium Phosphate, Water, Dilute Acids & Alkalis, EtcE) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 745 Spl / James Walker Inmarco Style 105 Sut / Champion Style 172 / Uniklinger Style 25 / Teadit Style 2003 / Pilot Gasket Style 2160 / Eagleburgmann StyleSpezial-Kombi K1 6430/K1 / Garlock Style 5200 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packing Shall Be Supplied In Tangentially Machine Cut At 45*.3) Vendor To Supply Gland Packing Rings In Set, One Set = 12 Nos Of Packing Rings. , Ready Cut Gland Packing A) Type: Dense Braided Packing Having Pure Aramid Fibres Corners With Pure Ptfe Fibres At The Running Surface And High Tensile Core Of Extruded & Expanded Ptfe Cord. B) Size (Readycut): 33 Mm Od X 17 Mm Id X 8 Mm C/SC) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 500 Bar (Static) / 150 Bar (Rotary)/ 500 Bar (Reciprocating) 3) Ph Range: 1-13 D) Applications:Pumps & Valves Handling Ammonia, Urea & Carbamate Condensate, Amide, Hydrazine, Tri-Sodium Phosphate, Water, Dilute Acids & Alkalis, EtcE) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 745 Spl / James Walker Inmarco Style 105 Sut / Champion Style 172 / Uniklinger Style 25 / Teadit Style 2003 / Pilot Gasket Style 2160 / Eagleburgmann StyleSpezial-Kombi K1 6430/K1 / Garlock Style 5200Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packing Shall Be Supplied In Tangentially Machine Cut At 45*. , Ready Cut Gland Packing A) Type: Dense Braided Packing Having Pure Aramid Fibres Corners With Pure Ptfe Fibres At The Running Surface And High Tensile Core Of Extruded & Expanded Ptfe Cord. B) Size (Readycut): 31 Mm Od X 15 Mm Id X 8 Mm C/SC) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 500 Bar (Static) / 150 Bar (Rotary)/ 500 Bar (Reciprocating) 3) Ph Range: 1-13 D) Applications:Pumps & Valves Handling Ammonia, Urea & Carbamate Condensate, Amide, Hydrazine, Tri-Sodium Phosphate, Water, Dilute Acids & Alkalis, EtcE) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 745 Spl / James Walker Inmarco Style 105 Sut / Champion Style 172 / Uniklinger Style 25 / Teadit Style 2003 / Pilot Gasket Style 2160 / Eagleburgmann StyleSpezial-Kombi K1 6430/K1 / Garlock Style 5200 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packing Shall Be Supplied In Tangentially Machine Cut At 45*. , Ready Cut Gland Packing A) Type: Dense Braided Packing Having Pure Aramid Fibres Corners With Pure Ptfe Fibres At The Running Surface And High Tensile Core Of Extruded & Expanded Ptfe Cord. B) Size (Readycut): 58.5 Mm Od X 28.5 Mm Id X 15 Mm C/SC) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 500 Bar (Static) / 150 Bar (Rotary)/ 500 Bar (Reciprocating) 3) Ph Range: 1-13 D) Applications:Pumps & Valves Handling Ammonia, Urea & Carbamate Condensate, Amide, Hydrazine, Tri-Sodium Phosphate, Water, Dilute Acids & Alkalis, EtcE) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 745 Spl / James Walker Inmarco Style 105 Sut / Champion Style 172 / Uniklinger Style 25 / Teadit Style 2003 / Pilot Gasket Style 2160 / Eagleburgmann StyleSpezial-Kombi K1 6430/K1 / Garlock Style 5200 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packing Shall Be Supplied In Tangentially Machine Cut At 45*. , Ready Cut Gland Packing A) Type: Dense Braided Packing Having Pure Aramid Fibres Corners With Pure Ptfe Fibres At The Running Surface And High Tensile Core Of Extruded & Expanded Ptfe Cord. B) Size (Readycut): 27 Mm Od X 15 Mm Id X 6 Mm C/SC) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 500 Bar (Static) / 150 Bar (Rotary)/ 500 Bar (Reciprocating) 3) Ph Range: 1-13 D) Applications:Pumps & Valves Handling Ammonia, Urea & Carbamate Condensate, Amide, Hydrazine, Tri-Sodium Phosphate, Water, Dilute Acids & Alkalis, EtcE) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 745 Spl / James Walker Inmarco Style 105 Sut / Champion Style 172 / Uniklinger Style 25 / Teadit Style 2003 / Pilot Gasket Style 2160 / Eagleburgmann StyleSpezial-Kombi K1 6430/K1 / Garlock Style 5200 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packing Shall Be Supplied In Tangentially Machine Cut At 45*. , Gland Packing A) Type: High Grade Expanded Ptfe+Graphited Yarn Packing In Interlock Braid.B) Size: 10 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 200 Bar (Static) / 50 Bar (Rotary)/ 100 Bar (Reciprocating) 3) Ph Range: 0 - 14 Applications:Pumps & Valves Handling Dm Water, Condensate, Acids, Boiler Feed Water,Fuel-Lube Oil, Acid & Alkai, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style ‘Na 758Hspl.’ / James Walker Inmarco Style 501C / Champion Style 63 / Uniklinger Style 49 / Teadit Style 2007 / Pilot Gasket Style 2140 / Eagleburgmann StyleThermoflon Tr 6232 / Garlok Style5100 Gfo / Spitmann Style 36 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: High Grade Expanded Ptfe+Graphited Yarn Packing In Interlock Braid.B) Size:12 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 200 Bar (Static) / 50 Bar (Rotary)/ 100 Bar (Reciprocating) 3) Ph Range: 0 - 14 Applications:Pumps & Valves Handling Dm Water, Condensate, Acids, Boiler Feed Water,Fuel-Lube Oil, Acid & Alkai, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style ‘Na 758Hspl.’ / James Walker Inmarco Style 501C / Champion Style 63 / Uniklinger Style 49 / Teadit Style 2007 / Pilot Gasket Style 2140 / Eagleburgmann StyleThermoflon Tr 6232 / Garlok Style5100 Gfo / Spitmann Style 36 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: High Grade Expanded Ptfe+Graphited Yarn Packing In Interlock Braid.B) Size: 14 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 200 Bar (Static) / 50 Bar (Rotary)/ 100 Bar (Reciprocating) 3) Ph Range: 0 - 14 Applications:Pumps & Valves Handling Dm Water, Condensate, Acids, Boiler Feed Water,Fuel-Lube Oil, Acid & Alkai, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style ‘Na 758Hspl.’ / James Walker Inmarco Style 501C / Champion Style 63 / Uniklinger Style 49 / Teadit Style 2007 / Pilot Gasket Style 2140 / Eagleburgmann StyleThermoflon Tr 6232 / Garlok Style5100 Gfo / Spitmann Style 36 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: High Grade Expanded Ptfe+Graphited Yarn Packing In Interlock Braid.B) Size: 20 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: -200 °C To 280 °C2) Pressure: 200 Bar (Static) / 50 Bar (Rotary)/ 100 Bar (Reciprocating) 3) Ph Range: 0 - 14 Applications:Pumps & Valves Handling Dm Water, Condensate, Acids, Boiler Feed Water,Fuel-Lube Oil, Acid & Alkai, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style ‘Na 758Hspl.’ / James Walker Inmarco Style 501C / Champion Style 63 / Uniklinger Style 49 / Teadit Style 2007 / Pilot Gasket Style 2140 / Eagleburgmann StyleThermoflon Tr 6232 / Garlok Style5100 Gfo / Spitmann Style 36 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Ready Cut Gland Packing A) Type: Pure Ptfe Braided Packing With Break-In-Lubricant & Incorporating Ptfe Suspensoid. B) Size (Readycut): 48Mm Od X 32 Mm Id X 8 Mm C/SC) Operating Conditions:1) Temperature: -200 °C To 290 °C2) Pressure: 300 Bar (Static) / 150 Bar (Rotary)/ 350 Bar (Reciprocating) 3) Ph Range: 0 - 14 D) Applications:Rotary & Reciprocating Pumps, /Rods, Expansion Joints, Valves, Non-Lubricating Compressors, Mixers, Washers, Agitators, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 781L Spl. / James Walker Inmarco Style 508 / Champion Style 30 / Uniklinger Style Ukl54s / John Crane Style C1045 / Teadit Style 2006 / Pilot Gasket Style 2120L / Eagleburgmann Style Chemstar L 6226/L / Garlock Style Style 5888 / Spitmann Style 3 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packing Shall Be Supplied In Tangentially Machine Cut At 45*. 3) Vendor To Supply The Gland Packing In Set. One Set = 7 Nos Of Packing Rings. , Ready Cut Gland Packing A) Type: Homogenous Graphited Ptfe Yarns, Reinforced With Aramid Fibre In Each Yarn, With Special Hollow Silicon Rubber Core, Pre-Lubed, In Interlock Braid. B) Size (Readycut): 146 Mm Od X 110 Mm Id X 18 Mm C/SC) Operating Conditions:1) Temperature: -200 °C To 300°C2) Pressure: 350 Bar (Static) / 100 Bar (Rotary)/ 200 Bar (Reciprocating) 3) Ph Range: 0 - 14 D) Applications:Rotary & Reciprocating Pumps, Rods, Expansion Joints, Valves, Non-Libricating Compressors, Mixers, Washers, Agitators, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 802(Sr) Spl. / James Walker Inmarco Style 504 Arhc / Champion Style 30 / Uniklinger Style 4313 / John Crane Style C1065 Hc / Teadit Style 2070 / Pilot Gasket Style 2150G / Garlock Equi Style / Eagle Burgmann Equi. Style Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packing Shall Be Supplied In Tangentially Machine Cut At 45*. 3) Vendor To Supply The Gland Packing In Set. One Set = 4 Nos Of Packing Rings. , Gland Packing A) Type: Non Asbestos Packing Rope With A Central Core Of Inorganic Bulk Fibre And Outer Braided Jacket With Gas & Heat Resistant Inorganic Filament Yarn. Packing Shall Be Suitable For Static Sealing Application. B) Size: 4 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: 1400 °C2) Ph Range: 0 - 14 D) Applications:Hot Blast Valve, Furnace Door Sealing, Bf Toyer Assembly, Coke Oven Door Sealing & Caulking, Mill Door Sealing, Pouring Ladle, Etc. Boiler Doors.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 550 / James Walker Inmarco Style 160 / Champion Style 7000 / Uniklinger Style Ukl4303 / Teadit Style 5213-I / Pilot Gasket Style Ceramic Rope / Eagleburgmann Style Buraglas Ht-Si 9486 / Garlock Equi. Style / Spitmann Style 7916 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: Non Asbestos Packing Rope With A Central Core Of Inorganic Bulk Fibre And Outer Braided Jacket With Gas & Heat Resistant Inorganic Filament Yarn. Packing Shall Be Suitable For Static Sealing Application. B) Size: 6 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: 1400 °C2) Ph Range: 0 - 14 D) Applications:Hot Blast Valve, Furnace Door Sealing, Bf Toyer Assembly, Coke Oven Door Sealing & Caulking, Mill Door Sealing, Pouring Ladle, Etc. Boiler Doors.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 550 / James Walker Inmarco Style 160 / Champion Style 7000 / Uniklinger Style Ukl4303 / Teadit Style 5213-I / Pilot Gasket Style Ceramic Rope / Eagleburgmann Style Buraglas Ht-Si 9486 / Garlock Equi. Style / Spitmann Style 7916 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: Non Asbestos Packing Rope With A Central Core Of Inorganic Bulk Fibre And Outer Braided Jacket With Gas & Heat Resistant Inorganic Filament Yarn. Packing Shall Be Suitable For Static Sealing Application. B) Size: 8 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: 1400 °C2) Ph Range: 0 - 14 D) Applications:Hot Blast Valve, Furnace Door Sealing, Bf Toyer Assembly, Coke Oven Door Sealing & Caulking, Mill Door Sealing, Pouring Ladle, Etc. Boiler Doors.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 550 / James Walker Inmarco Style 160 / Champion Style 7000 / Uniklinger Style Ukl4303 / Teadit Style 5213-I / Pilot Gasket Style Ceramic Rope / Eagleburgmann Style Buraglas Ht-Si 9486 / Garlock Equi. Style / Spitmann Style 7916 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: Non Asbestos Packing Rope With A Central Core Of Inorganic Bulk Fibre And Outer Braided Jacket With Gas & Heat Resistant Inorganic Filament Yarn. Packing Shall Be Suitable For Static Sealing Application. B) Size: 10 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: 1400 °C2) Ph Range: 0 - 14 D) Applications:Hot Blast Valve, Furnace Door Sealing, Bf Toyer Assembly, Coke Oven Door Sealing & Caulking, Mill Door Sealing, Pouring Ladle, Etc. Boiler Doors.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 550 / James Walker Inmarco Style 160 / Champion Style 7000 / Uniklinger Style Ukl4303 / Teadit Style 5213-I / Pilot Gasket Style Ceramic Rope / Eagleburgmann Style Buraglas Ht-Si 9486 / Garlock Equi. Style / Spitmann Style 7916 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: Non Asbestos Packing Rope With A Central Core Of Inorganic Bulk Fibre And Outer Braided Jacket With Gas & Heat Resistant Inorganic Filament Yarn. Packing Shall Be Suitable For Static Sealing Application. B) Size: 12 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: 1400 °C2) Ph Range: 0 - 14 D) Applications:Hot Blast Valve, Furnace Door Sealing, Bf Toyer Assembly, Coke Oven Door Sealing & Caulking, Mill Door Sealing, Pouring Ladle, Etc. Boiler Doors.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 550 / James Walker Inmarco Style 160 / Champion Style 7000 / Uniklinger Style Ukl4303 / Teadit Style 5213-I / Pilot Gasket Style Ceramic Rope / Eagleburgmann Style Buraglas Ht-Si 9486 / Garlock Equi. Style / Spitmann Style 7916 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland Packing A) Type: Non Asbestos Packing Rope With A Central Core Of Inorganic Bulk Fibre And Outer Braided Jacket With Gas & Heat Resistant Inorganic Filament Yarn. Packing Shall Be Suitable For Static Sealing Application. B) Size: 14 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: 1400 °C2) Ph Range: 0 - 14 D) Applications:Hot Blast Valve, Furnace Door Sealing, Bf Toyer Assembly, Coke Oven Door Sealing & Caulking, Mill Door Sealing, Pouring Ladle, Etc. Boiler Doors.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 550 / James Walker Inmarco Style 160 / Champion Style 7000 / Uniklinger Style Ukl4303 / Teadit Style 5213-I / Pilot Gasket Style Ceramic Rope / Eagleburgmann Style Buraglas Ht-Si 9486 / Garlock Equi. Style / Spitmann Style 7916 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: Abrasion/Brine Resistant Packing Manufactured From Co-Polymer Fiber Yarn Thoroughly Impregnated With Ptfe And Further Impregnated With Break-In-Lubricant And A Surface Run-In-Lubricant. B) Size: 6 Mm Sq. Cross-Section C) Operating Conditions:1) Temperature: -200°C To 300°C2) Pressure: 500 Bar3) Ph Range: 1-13 D) Applications:Pumps, Valves, Mixers, Reactors, Etc Handling Chemical Slurries, Coolant, Dry Powdered Chemicals, Turbid Water, Surface Water, Saline Sea Water, Brines, Fuel Oil, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 747Spl / James Walker Inmarco Style 705 / Champion Style 174-S / Teadit Style 2006 / Pilot Gasket Style 3001 / Eagleburgmann Style Burasoft 6225/L / Garlock Equi. Style / Spitmann Style 1094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: Abrasion/Brine Resistant Packing Manufactured From Co-Polymer Fiber Yarn Thoroughly Impregnated With Ptfe And Further Impregnated With Break-In-Lubricant And A Surface Run-In-Lubricant. B) Size: 8 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: -200°C To 300°C2) Pressure: 500 Bar3) Ph Range: 1-13 D) Applications:Pumps, Valves, Mixers, Reactors, Etc Handling Chemical Slurries, Coolant, Dry Powdered Chemicals, Turbid Water, Surface Water, Saline Sea Water, Brines, Fuel Oil, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 747Spl / James Walker Inmarco Style 705 / Champion Style 174-S / Teadit Style 2006 / Pilot Gasket Style 3001 / Eagleburgmann Style Burasoft 6225/L / Garlock Equi. Style / Spitmann Style 1094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: Abrasion/Brine Resistant Packing Manufactured From Co-Polymer Fiber Yarn Thoroughly Impregnated With Ptfe And Further Impregnated With Break-In-Lubricant And A Surface Run-In-Lubricant. B) Size: 10 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: -200°C To 300°C2) Pressure: 500 Bar3) Ph Range: 1-13 D) Applications:Pumps, Valves, Mixers, Reactors, Etc Handling Chemical Slurries, Coolant, Dry Powdered Chemicals, Turbid Water, Surface Water, Saline Sea Water, Brines, Fuel Oil, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 747Spl / James Walker Inmarco Style 705 / Champion Style 174-S / Teadit Style 2006 / Pilot Gasket Style 3001 / Eagleburgmann Style Burasoft 6225/L / Garlock Equi. Style / Spitmann Style 1094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: Abrasion/Brine Resistant Packing Manufactured From Co-Polymer Fiber Yarn Thoroughly Impregnated With Ptfe And Further Impregnated With Break-In-Lubricant And A Surface Run-In-Lubricant. B) Size: 12 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: -200°C To 300°C2) Pressure: 500 Bar3) Ph Range: 1-13 D) Applications:Pumps, Valves, Mixers, Reactors, Etc Handling Chemical Slurries, Coolant, Dry Powdered Chemicals, Turbid Water, Surface Water, Saline Sea Water, Brines, Fuel Oil, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 747Spl / James Walker Inmarco Style 705 / Champion Style 174-S / Teadit Style 2006 / Pilot Gasket Style 3001 / Eagleburgmann Style Burasoft 6225/L / Garlock Equi. Style / Spitmann Style 1094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: Abrasion/Brine Resistant Packing Manufactured From Co-Polymer Fiber Yarn Thoroughly Impregnated With Ptfe And Further Impregnated With Break-In-Lubricant And A Surface Run-In-Lubricant. B) Size: 14 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: -200°C To 300°C2) Pressure: 500 Bar3) Ph Range: 1-13 D) Applications:Pumps, Valves, Mixers, Reactors, Etc Handling Chemical Slurries, Coolant, Dry Powdered Chemicals, Turbid Water, Surface Water, Saline Sea Water, Brines, Fuel Oil, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 747Spl / James Walker Inmarco Style 705 / Champion Style 174-S / Teadit Style 2006 / Pilot Gasket Style 3001 / Eagleburgmann Style Burasoft 6225/L / Garlock Equi. Style / Spitmann Style 1094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: Abrasion/Brine Resistant Packing Manufactured From Co-Polymer Fiber Yarn Thoroughly Impregnated With Ptfe And Further Impregnated With Break-In-Lubricant And A Surface Run-In-Lubricant. B) Size: 16 Mm Sq. Cross-SectionC) Operating Conditions:1) Temperature: -200°C To 300°C2) Pressure: 500 Bar3) Ph Range: 1-13 D) Applications:Pumps, Valves, Mixers, Reactors, Etc Handling Chemical Slurries, Coolant, Dry Powdered Chemicals, Turbid Water, Surface Water, Saline Sea Water, Brines, Fuel Oil, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 747Spl / James Walker Inmarco Style 705 / Champion Style 174-S / Teadit Style 2006 / Pilot Gasket Style 3001 / Eagleburgmann Style Burasoft 6225/L / Garlock Equi. Style / Spitmann Style 1094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Graphited Non-Asbestos, Self Lubricated Gland Packing. Manufactured From Heat & Chemical Resistant Inorganic Refractory Oxides In Fibrous Form. B) Size: 1/4 Inch Sq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Super Heated & Saturated Steam, All Non-Oxidising Liquids & Gases,Chemicals, Water,Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 442 / James Walker Inmarco Style 141 / Champion Style 668-Nm / Uni Klinger Equi. Style / John Crane Style G58 / Slade Style 3300 G / Teadit Style 500-I / Pilot Gasket Equi. Style / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 66 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Graphited Non-Asbestos, Self Lubricated Gland Packing. Manufactured From Heat & Chemical Resistant Inorganic Refractory Oxides In Fibrous Form. B) Size: 5/16 Inchsq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Super Heated & Saturated Steam, All Non-Oxidising Liquids & Gases,Chemicals, Water,Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 442 / James Walker Inmarco Style 141 / Champion Style 668-Nm / Uni Klinger Equi. Style / John Crane Style G58 / Slade Style 3300 G / Teadit Style 500-I / Pilot Gasket Equi. Style / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 66 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Graphited Non-Asbestos, Self Lubricated Gland Packing. Manufactured From Heat & Chemical Resistant Inorganic Refractory Oxides In Fibrous Form. B) Size: 3/8 Inch Sq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Super Heated & Saturated Steam, All Non-Oxidising Liquids & Gases,Chemicals, Water,Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 442 / James Walker Inmarco Style 141 / Champion Style 668-Nm / Uni Klinger Equi. Style / John Crane Style G58 / Slade Style 3300 G / Teadit Style 500-I / Pilot Gasket Equi. Style / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 66 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Graphited Non-Asbestos, Self Lubricated Gland Packing. Manufactured From Heat & Chemical Resistant Inorganic Refractory Oxides In Fibrous Form. B) Size: 1/2 Inch Sq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Super Heated & Saturated Steam, All Non-Oxidising Liquids & Gases,Chemicals, Water,Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 442 / James Walker Inmarco Style 141 / Champion Style 668-Nm / Uni Klinger Equi. Style / John Crane Style G58 / Slade Style 3300 G / Teadit Style 500-I / Pilot Gasket Equi. Style / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 66 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Graphited Non-Asbestos, Self Lubricated Gland Packing. Manufactured From Heat & Chemical Resistant Inorganic Refractory Oxides In Fibrous Form. B) Size: 1 Inch Sq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Super Heated & Saturated Steam, All Non-Oxidising Liquids & Gases,Chemicals, Water,Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 442 / James Walker Inmarco Style 141 / Champion Style 668-Nm / Uni Klinger Equi. Style / John Crane Style G58 / Slade Style 3300 G / Teadit Style 500-I / Pilot Gasket Equi. Style / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 66 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Non-Asbestos Gland Packing. Manufactured From Inorganic Refractory Fibre Yarn Duplex Braided Packing Impregnated With Ptfe Dispersion Incorporating Break In Lubricant. B) Size: 1/4 Inch Sq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Acid & Alkalies, All Non-Oxidising Liquids And Gases, Chemicals, Dm Water, Condensate, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 441 / James Walker Inmarco Style 125F / Champion Style 6094 / Uni Klinger Style Ukl49 / John Crane Style C-1045 / Teadit Style 2090 / Pilot Gasket Style 2120 / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 3094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Non-Asbestos Gland Packing. Manufactured From Inorganic Refractory Fibre Yarn Duplex Braided Packing Impregnated With Ptfe Dispersion Incorporating Break In Lubricant. B) Size: 3/8 Inch Sq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Acid & Alkalies, All Non-Oxidising Liquids And Gases, Chemicals, Dm Water, Condensate, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 441 / James Walker Inmarco Style 125F / Champion Style 6094 / Uni Klinger Style Ukl49 / John Crane Style C-1045 / Teadit Style 2090 / Pilot Gasket Style 2120 / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 3094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Non-Asbestos Gland Packing. Manufactured From Inorganic Refractory Fibre Yarn Duplex Braided Packing Impregnated With Ptfe Dispersion Incorporating Break In Lubricant. B) Size: 5/16 Inch Sq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Acid & Alkalies, All Non-Oxidising Liquids And Gases, Chemicals, Dm Water, Condensate, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 441 / James Walker Inmarco Style 125F / Champion Style 6094 / Uni Klinger Style Ukl49 / John Crane Style C-1045 / Teadit Style 2090 / Pilot Gasket Style 2120 / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 3094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Non-Asbestos Gland Packing. Manufactured From Inorganic Refractory Fibre Yarn Duplex Braided Packing Impregnated With Ptfe Dispersion Incorporating Break In Lubricant. B) Size: 1/2 Inch Sq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Acid & Alkalies, All Non-Oxidising Liquids And Gases, Chemicals, Dm Water, Condensate, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 441 / James Walker Inmarco Style 125F / Champion Style 6094 / Uni Klinger Style Ukl49 / John Crane Style C-1045 / Teadit Style 2090 / Pilot Gasket Style 2120 / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 3094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack. , Gland PackingA) Type: General Purpose Non-Asbestos Gland Packing. Manufactured From Inorganic Refractory Fibre Yarn Duplex Braided Packing Impregnated With Ptfe Dispersion Incorporating Break In Lubricant. B) Size: 5/8 Inch Sq. Cross-SectionC) Operating Conditions:1) Temperature:300°C2) Pressure: 100 Bar3) Ph Range: 0-14D) Applications:Suitable For Acid & Alkalies, All Non-Oxidising Liquids And Gases, Chemicals, Dm Water, Condensate, Etc.E) Make & Style Of Gland Packing:Jd Jones (Pacmaan) Style Na 441 / James Walker Inmarco Style 125F / Champion Style 6094 / Uni Klinger Style Ukl49 / John Crane Style C-1045 / Teadit Style 2090 / Pilot Gasket Style 2120 / Eagleburgmann Equi. Style / Garlock Equi. Style / Spitmann Style 3094 Only.Notes:1) Gland Packing Shall Be Properly Packed & Delivered To Rcf.2) The Packings Shall Be Supplied In 1 Kg Pack.
Contract Date: Feb 23, 2023 Contract Value : 4.86 Lakh
Boards / Undertakings / PSU No of Bidders 4
Maharashtra View Result →
19.
Defence #1812248 AOC
Providing Of Ph-I Of Otm Accn For Mech Inf Bn At Ferozepur Under Ge ( East ) Ferozepur Cantt-- 1 Note: (i) Please refer Schedule A Notes given on serial page No. 21 to 27 of tender documents. 2 LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS 3 Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule A Part-I brought forward from serial page No. 29. 4 Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTHWORKS as listed in Schedule A Part-II brought forward from serial page No. 30. 5 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule A Part-III brought forward from serial page No. 37. 6 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule A Part-IV brought forward from serial page No. 38. 7 Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule A Part-V brought forward from serial page No. 40. 8 Lump sum price worked out by the contractor for ROAD, PATHAND CULVERTS WORKS as listed in Schedule A Part-VI brought forward from serial page No. 42. 9 Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule A Part-VII brought forward from serial page No. 43. 10 Lump sum price worked out by the contractor for BOUNDARY WALL, COMPOUND WALL,FENCING AND GATE WORKS listed in Schedule A Part-VIII brought forward from serial page No. 45. 11 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYWORKS as listed in Schedule A Part-IX brought forward from serial page No. 46. 12 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONWORKS as listed in Schedule A Part-X brought forward from serial page No. 50. 13 Lump sum price worked out by the contractor for DG SET WORKS as listed in Schedule A Part-XI brought forward from serial page No. 51. 14 Lump sum price worked out by the contractor for SUMMER APPLIANCES WORKSas listed in Schedule A Part-XII brought forward from serial page No. 53. 15 Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKSas listed in Schedule A Part-XIII brought forward from serial page No. 54. 16 Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS as listed in Schedule A Part-XIV brought forward from serial page No. 56. 17 Lump sum price worked out by the contractor forLIGHTENING CONDUCTOR WORKS as listed in Schedule A Part-XV brought forward from serial page No. 57. 18 Lump sum price worked out by the contractor for BORE WELL WORKS as listed in Schedule A Part-XVI brought forward from serial page No. 58. 19 Lump sum price worked out by the contractor for STP WORKS as listed in Schedule A Part-XVII brought forward from serial page No. 59. 20 Lump sum price worked out by the contractor for TREATED SEWAGE WATER SUPPLY WORKS as listed in Schedule A Part-XVIII brought forward from serial page No. 60. 21 Lump sum price worked out by the contractor for PCC HARD STANDING WORKS as listed in Schedule A Part-XIX brought forward from serial page No. 61. 22 SCHEDULE A PART-XX MISC ITEMS INTERNAL ELECTRIFICATION WORKS 23 Supply and Fix energy efficient LED bulb, B229 Watt complete all as specified and directed. Make:- Cat No LHLDBWEB4L8R009 of Havells or eqvt in Philips and CG. 24 Supply and Fix Modular RJ telephone socketcomplete all as specified and directed by Engr -in- Charge. Make:- Cat No / SAP code AHLKHWW000 of Havells or eqvt in Legrand/ Schneider. 25 Supply and Fix Modular TV Socket complete all as specified and directed by Engr -in- Charge.Cat No /SAP code AHLKT0W000 of Havells or eqvt in Legrand/ Schneider. 26 Supply and FixDecorative 9W LEDwall mounting fittings complete set including 9 W LED lamp all as specified and directed. Make:- Cat No LHF0ECEITZIB014 Glaze Wall Light of Havellsor eqvt in Philips / Crompton. 27 S&F GI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5 mtr long MS clamps made out of MS flat iron of size 25x4 mm thick with nuts & bolts, washers complete as specified and directed 28 Supply and fix wall mounting fan industrial type 450mm sweep, 230V, 50Hz , 1400 RPM, 100W, 150cum/hr air delivery, copper motor, double ball bearing , 60dB - 65dB nosie level, upward and down adjustable, 60 degree oscillation degree, 3 Nos metal balde guarded with 112 spokes metal case complete with mountings accessories kit, wall bracket, nut, bolt washer etc with connection PVC three core copper wire all as specified and directed. Make:- Cat No FHACWSTSCL18 of Havells or eqvt in Legrand/ Philips. 29 SEWAGE DISPOSAL WORKS 30 Material and labour for laying DWC HDPE 150mm (I/D) SN8 pipe including all necessary fittings for carrying sewage complete all as directed by Engineer in Charge. 31 Material and labour for laying DWC HDPE 200mm (I/D) SN8 pipe including all necessary fittings for carrying sewage complete all as directed by Engineer in Charge. 32 Material and labour for construction of under gournd sump cum pump house complete all as shown on drawings and as specified. (Drg No CEJZ-04/2000 Sheet No. 1/2 to 2/2). 33 ROAD, PATHAND CULVERTS WORKS 34 Material and labour for cat eye abs plastic with nail of size 100mm x 100mm, 20mm reflective glass colour White/ Red/ Yellow provided with steel zinc plated with bolt of 12mm dia length 120mm for fixing on road by hammering complete all as directed by Engineer in Charge. 35 Material and labour for delineator 47mm dia 600mm long with high intensity reflective sheeting complete all as directed by Engineer-in-Charge. 36 EXTERNAL WATER SUPPLY WORKS 37 Supplying, laying, jointing and testing in trenches centrifugally cast 150mm bore ductile iron pipe class K-7 conforming to IS : 8329-2000 of min wall thickness 5.4mm including testing complete all as specified. 38 Supplying, laying, jointing and testing in trenches centrifugally cast 100mm bore ductile iron pipe class K-7 conforming to IS : 8329-2000 of min wall thickness 5.4mm including testing complete all as specified Notes for Srl No. 6.01 & 6.02 :-(a) Excavation, earth work and DI fittings shall be measured and paid for separately under respective items(b) Cost of tyton joints is included in the rate quoted.(c) Standard length of the pipe should be 5.50m or 6.0m as available.(d) The measurement of the pipe shall be net as fixed between the fittings including short length without any allowance for cutting and wastage and for the portion entering in the socket of all pipes and fittings.(e) Predespatch inspection & testing of DI pipe shall be carried out by the representative of AO. All the expenditure for the same shall be borne by the contractor and the quoted rates shall be deemed to be included for the same 39 Supply, fixing and testing ductile iron fittings such as bends (any type radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction. Double branch, cross (all sockets or sockets and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket. Spigot caps and plugs suitable for 100 to 150mm ductile iron pressure pipes of K-7 classification and push on flexible rubber gasket joints complete all as specified and directedNotes :(a) DI fittings shall be of same make as of DI pipes or of make as recommended by manufacturers(b) The weight of the fittings shall be measured and paid as given in relevant IS or actually provided whichever is less.(c) All fittings shall be relevant IS stamping marking.(d) Excavation and earth work shall be measured and paid for separately.(e) Cost of the joints and jointing materials shall be deemed to be included in the relevant items of DI pipes here-in-before 40 Construction of brick masonary valve pit chamber of 1050mm x 750mm x 1000mm size (internal dimensions) with MS sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified and shown on drgs. Breakdown of QtyExternal Water Supply-4 (Each)Treated Sewage Water Supply-2 (Each) 41 Construction of brick masonary valve pit chamber of 900 x 900 x 1000mm size (internal dimensions) with MS sheet cover 6mm thick and angle iron 40 x 40 x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. Breakdown of QtyExternal Water Supply-5 (Each)Treated Sewage Water Supply-3 (Each) 42 Construction of brick masonary valve pit chamber of 600mm x 600mm x 1000mm size (internal dimensions) with MS sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. Note for Srl item No. 6.04 to 6.06:- 43 Supply and fixing RCC water main route indicator of size 75cm x 40cm x 10cm duly marked with MES Water Mains Bore made of cement concrete (1:2:4) type B-1 as in foundation of electric poles/ struts etc including necessary form work, fair, finished embedded in PCC bed including necessary excavation and re-filling, proposed to be installed after 25m on pipe lines of size 150mm, 100mm, 80mm and 50mm complete all as directed by Engineer-in-Charge. 44 EXTERNAL ELECTRIC SUPPLY WORKS 45 Supply ,install, testing and commissioning power factor control LT panel board (APFC) of 200 KVAR, 433 volt, 50 Cycle per second cubical type front and back openable double leaf type dust & vermin proof with locking arrangement powder coated with approved colour , made out of CRCA sheet 14 SWG, outdoor herewith canopy, cable entry glands, double compressor type, duly prewired with suitable pillar made out of 50 mmx 50mm x6 mm angle iron grouted in and including PCC (1:2:4) using 20 mm graded stone aggregate complete all as per IS 8623-1933 & all as per latest ISI specification and suitable for housing and including following accessories :- (a) Incoming MCCB of 250 Amps 36 KA rupturing capacity , 3 Pole thermal magnetic release type shunt trip coil -01 No (b) Copper Bus bar duly insulated with colour coded heat shrinkable sleeve insulation for three phase four wire system of 250 Amps capacity rating with suitable size/ type on hygroscopic on combustion track resistance, high strength FRP/MC/DMC insulators.(c) Capacitor switching contactor of suitable capacity (contractor amps rating shell not be less than 1.5 times nominal current rating, three pole, coil voltage 440 Volts, one each for number of capacitor bank , each contractor shell be protected with 10 KA , d curve type (MCB to be provided for 1.33 times KVAR i.e. 100 % current capacity of the MPFCS irrespective of the fact that contractor’s rating is 1.5 times) (MCCB 25 KA shall be provided for the above 63 Amps rating)(d) One set current transformer (CTs) of suitable ratio (with secondary of 5 Amps ) to be fixed on bus bar of existing panel including connection with 2 core 1.5 Sqmm armoured copper conductor complete with gland etc.(e) Shunt capacitor MPP type heavy duty 200 KVAR distributed in step of 6 steps with configuration (2x12.5 + 1x25 + 3x50) directly connected to maintain power factor at 0.99 or unity, housed in self-extinguishing insulated material with built in. 46 Supply and fixing 3 core 1.5 sqmm PVC insulated and FRLS PVC round sheathed copper conductor flexible 1100 volts for connection from Junction Box to street light fittings complete all as specified and directed. Make :Polycab/ Havells/ Finolex/ Paragon 47 Supply and fixing street light pole cable junction box IP-65 with metric knockouts for cable entry with MCB SP 6 Amps,10 KA and the box made out of thermal plastic material suitable for 16/25 Sqmm UG cable including clamps bolts, nuts, duly painted etc complete all as and directed by Engineer-in-Charge. 48 Supply and fixing bracket made out of 40 mm dia GI light grade tubing 1.2 meter long and bent to angle /shape of 120 degree angle at the meddle from vertical fixed with clamps nuts and bolts washers complete all as specified and directed 49 Supply and fixing automatic street light switchfor automatic switching of street light/high mast light (timer switch)for Three Phase Loadlight.The Digital timer 24 hrs alongwith suitable power contractor as per IEC - 60947-4-1, including incoming & outgoing MCBs, SMC Enclosure and support terminal and enclosed in pole/wall mounted factory made PVC enclosure made out of rust proof, shock & termite proof and FRLS grade confirming to IP-54 of capacity 6 KW, Three phase, Current rating 32/TP and MCB rating 40/TPN, having facility of manual operation complete all as directed by Engineer-in-Charge. 50 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC,3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.8 m x 1.5 m x 1.0 m) painted with Synthetic enamel Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Main Panel (X-Mer - 400 KVA)(i) Panel having common aluminium bus bar of capacity 1600 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)ACB Microprocessor released and thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 800 Amp 4 Pole, 50 KAwith overload variation 40-100%- 1 No,(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 Amp 3 Pole, 35 KA with overload variation 40-100%- 1 No,(for APFC ) (b)-do- but 250 Amp - 1 No, (c)-do- but 160 Amp - 1 No, (d)-do- but 125 Amp - 02 Nos,(e)-do- but 63 Amp - 6 Nos,(iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 800 Amps digital type square shape 96mm flush mounted with selector switch and CTs 800/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 51 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC,3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Near SMBK(i) Panel having common aluminium bus bar of capacity 500 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 Amp 4 Pole, 35 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, 16 KA with overload variation 40-100%- 4 Nos. (b)-do- but 32 Amp - 2 Nos, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 250 Amps digital type square shape 96mm flush mounted with selector switch and CTs 250/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 52 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtrbelow GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Near JCO MESS(i) Panel having common aluminium bus bar of capacity 320 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160 Amp 4 Pole, ICU=ICS=35 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a) MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 80 Amp 4 Pole, ICU=ICS=25 KA with overload variation 40-100%-1 No. (b)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 4 Nos. (c)MCB isolator 25 Amp SPN 10 KA, 240V-01 No, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 160 Amps digital type square shape 96mm flush mounted with selector switch and CTs 160/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 53 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Near Offr MESS(i) Panel having common aluminium bus bar of capacity 250 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 Amp 4 Pole, ICU=ICS=25 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 2 Nos. (b)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=25 KA with overload variation 40-100%- 2 Nos. (c)MCB isolator 32 Amp SPN 10 KA, 240V-04 Nos, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 125 Amps digital type square shape 96mm flush mounted with selector switch and CTs 125/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 54 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Near Adm Block(i) Panel having common aluminium bus bar of capacity 250 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 Amp 4 Pole, ICU=ICS=25 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 2 Nos. (b)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=25 KA with overload variation 40-100%- 2 Nos. (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 125 Amps digital type square shape 96mm flush mounted with selector switch and CTs 125/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 55 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - MT area panel(i) Panel having common aluminium bus bar of capacity 200 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 4 Nos. (b)MCB isolator 25 Amp SPN 10 KA, 240V-10 Nos. (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 100 Amps digital type square shape 96mm flush mounted with selector switch and CTs 100/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 56 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.4 m x 1.25 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Street light panel(i) Panel having common aluminium bus bar of capacity 200 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 3 Nos. (b)ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amp. (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 100 Amps digital type square shape 96mm flush mounted with selector switch and CTs 100/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 NosNote Srl item No. 7.06 to 7.12:- LT Panel shall be got tesed from CPRI type test for 4000 Amp with breaking capacity not less than 65 KA and IP 56 as per IS 61439 Part- 1& 2. 57 Supply and fixing of rubber mat (Insulation mat) of dimension 1m x 2m and 2 mm thick complete for electrical installation and DG sets panels complete all as directed by Engineer-in-Charge. 58 Supply and fixing of rubber mat of dimension 1m x 2m and 3 mm thick complete for electrical installation and STP main panels complete all as specified and directed. 59 Supply and fixing RCC HT cable route indicator of size 75cmx40cmx10cm duly marked with HT cable made ofcement concreted (1:2:4) type B-1 as in foundation of electric poles/struts/ etc including necessary form work, fair finished embedded in PCC bed including necessary excavation and re-filling complete all as specified and directed 60 DG SET WORKS 61 Supply, installing, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB conditions/ norms, 62.5 KVA, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. The diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the CPCB approved acoustic enclosure. The complete set conforming to and test certificate as per CPCB norms and as specified) complete without AMF control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following:-(a) Engine (Prime mover) : Diesel engine 1500 RPM of minimum 84 BHP or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self-starter, alternator, cogged V belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) Alternator :Alternator AC 3 phase 415 Volts 4 wire rated line current for output 62.5 KVA, PF 0.8, 1500 RPM insulation class enclosures /SPDP self-exited self-regulated brushes, complete with AVR with plus and minus voltage regulation directly coupled to and match the above engine. (c) Anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) Base plate made out of structural steel as per manufacturer recommended design/specification.(e) Acoustic enclosure of an internal type approved/certified acoustic enclosure (as per CPCB norms for the DG Set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. It shall be made of 16 SWG or manufacturer standard norms CRCA sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. The doors and glass windows shall be ISMC. It shall also include the following:-(i) Silencer/Absorption the non-resistance, residential and exhaust pipe covered with asbestos rope.(ii) Internal wiring with PVC copper conductor cable IS-694 marked FRLS in conduit and fluorescent lamp fittings.(iii) Fuel tank of 16 hours cap but not less than made of 14 SWG CRCA sheet duly powder coated and provided with float gauge and fuel float switch.(iv) One No 12 V X 180 AH 25 plates maintenance free batteries as recommended by manufacturer.(f) The exhaust of DG set shall be fitted with emission control devises as per latest CPCB norms and as specified and also contractor shall submit test certificate of DG set as per latest CPCB norms. 62 Supply, installing, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB conditions/ norms, 40 KVA, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. The diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the CPCB approved acoustic enclosure. The complete set conforming to and test certificate as per CPCB norms and as specified) complete without AMF control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following:-(a) Engine (Prime mover) : Diesel engine 1500 RPM of minimum 51 BHP or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self-starter, alternator, cogged V belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) Alternator :Alternator AC 3 phase 415 Volts 4 wire rated line current for output 40 KVA, PF 0.8, 1500 RPM insulation class enclosures /SPDP self-exited self-regulated brushes, complete with AVR with plus and minus voltage regulation directly coupled to and match the above engine. (c) Anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) Base plate made out of structural steel as per manufacturer recommended design/specification.(e) Acoustic enclosure of an internal type approved/certified acoustic enclosure (as per CPCB norms for the DG Set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. It shall be made of 16 SWG or manufacturer standard norms CRCA sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. The doors and glass windows shall be ISMC. It shall also include the following:-(i) Silencer/Absorption the non-resistance, residential and exhaust pipe covered with asbestos rope.(ii) Internal wiring with PVC copper conductor cable IS-694 marked FRLS in conduit and fluorescent lamp fittings.(iii) Fuel tank of 16 hours cap but not less than made of 14 SWG CRCA sheet duly powder coated and provided with float gauge and fuel float switch.(iv) One No 12 V X 88 AH 25 plates maintenance free batteries as recommended by manufacturer.(f) The exhaust of DG set shall be fitted with emission control devises as per latest CPCB norms and as specified and also contractor shall submit test certificate of DG set as per latest CPCB norms. 63 SUMMER APPLIANCES WORKS 64 Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 1.0 KVA complete all as directed by Engineer-in-Charge. 65 Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 2.0 KVA complete all as directed by Engineer-in-Charge. 66 Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 3.0 KVA complete all as directed by Engineer-in-Charge. 67 Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 5.0 KVA complete all as directed by Engineer-in-Charge. 68 Supply and installed refrigerators, electric driven (single phase) of capacity 220 Ltrs frost free, 5 star rated complete all as directed by Engineer-in-Charge. 69 Supply and installed refrigerators, electric driven (single phase) of capacity 400 Ltrs frost free, 5 star rated complete all as directed by Engineer-in-Charge. 70 Supply and installing desert cooler electric driven (single phase) having nominal air flow capacity of 4000 Cum/ Hrs 230V made of 20 gauge MS sheet and size not less than 90cm, 78cm x 78cm surface area from top and bottom 62cm x 54cm front grill size including tullu pump with rotary switch (4 speed) 5 Amp switch on front side, drain valve including two coats synthetic of enamel paint over a coat of primer complete all as directed by Engineer in Charge. 71 RAIN WATER HARVESTING WORKS 72 Material and labour for gravel packing including jute as filter media 4mm to 6mm size around MS pipe complete all as directed by Engineer-in-Charge. 73 Material and labour for filling of gravel in trenches of size 6mm to 10mm upto height of 0.50m complete all as directed by Engineer-in-Charge. 74 Material and labour for filling of gravel in trenches of size 2mm to 4mm upto height of 1.0m complete all as directed by Engineer-in-Charge. 75 BORE WELL WORKS 76 Material and labour for Drilling of 675mm bore hole from ground level to 20 m depth below ground levelin any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed :-Notes :(a) Record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) The bore/tube well should be constructed by the agency as approved by GE (East) Fzr.(c) The Rates also includes transportation of Rig Machine & T&P at Site.(d) Trail Bore will be drilled, if sufficient wet strata is available then ERW casing will be lowered. In case Strata is not available payment only for drilling will be made 77 All as per Srl item No. 11.01 here-in-before but from 20 m below ground level to 40 m depth below ground level. 78 All as per Srl item No. 11.01 here-in-before but from 40 m below ground level to 60 m depth below ground level. 79 Material and labour for Drilling of 525 mm bore hole from 60 mtr below ground level to 85 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed :-Notes :(a) Record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) The bore/tube well should be constructed by the agency as approved by GE (East) Fzr.(c) The Rates also includes transportation of Rig Machine & T&P at Site.(d) Trail Bore will be drilled, if sufficient wet strata is available then ERW casing will be lowered. In case Strata is not available payment only for drilling will be made 80 All as per Srl item No. 11.04 here-in-before but from 85 m below ground level to 110 m depth below ground level. 81 All as per Srl item No. 11.04 here-in-before but from 110 m below ground level to 135 m depth below ground level. 82 Material and labour for Drilling of 450 mm bore hole from 135 mtr below ground level to 160 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes of following diameters complete all as specified and as directed :-Notes :(a) Record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) The bore/tube well should be constructed by the agency as approved by GE (East) Fzr.(c) The Rates also includes transportation of Rig Machine & T&P at Site.(d) Trail Bore will be drilled, if sufficient wet strata is available then ERW casing will be lowered. In case Strata is not available payment only for drilling will be made 83 All as per Srl item No. 11.07 here-in-before but from 160 m below ground level to 185 m depth below ground level. 84 All as per Srl item No. 11.07 here-in-before but from 185 m below ground level to 200 m depth below ground level. 85 Material and labour for electrical Logging of bore well and after electrical logging report of Assembly Design and submission of lithological log report for approval of GE complete. 86 Supply and fixing 350 mm bore ERW mild steel housing pipe 8mm wall thickness duly painted with primer and anti-corrosive paint with screwed and socket ends in standard length of 3 metre or as required at site, complete with coupling, welding at joints as required (ISI marked : IS-4270-1992) including cutting,lowering, jointing and fixing in position, complete all as specified (Measured net as fixed). 87 All as per Srl item No. 11.11 here-in-before but 250 mm bore pipe with 8 mm wall thickness. 88 Supply and fixing low carbon galvanised iron screen filter (slotted) 250mm bore pipe with slots 0.2 mm to 1.5 mm, 6.4mm wall thickness duly painted with ferrous primer and anti-corrosive bituminous paint including screwed and socket ends in standard length, welding and fixing support having slots 0.2 mm to 1.5 mm depending upon nature of aquifers sediments, complete including lowering and fixing in position, confirming to IS-4270-1992, complete all as specified (Measured net as fixed) 89 Supply and fixing Mild steel reducing socket for connecting 350mm bore housing pipe with 250mm bore blind pipe with minimum 8.0 mm wall thickness including welding and fixing support complete all as specified and directed 90 Supply and fixing Mild steel bail plug suitable for 250 mm bore pipe 1.5 metre long having wall thickness of 8.0 mm with strong iron hooks, complete all as specified and directed 91 Supply and fixing well cap fabricated out of 6 mm thick mild steel sheet for 350mm bore housing pipe threaded similar to housing pipe with handle made and of 20mm dia mild steel round bar, complete all as specified and directed 92 Material and labour for mild steel flat iron 75mmx6mm as centre guides (set of three), standard pattern for 350/250 mm bore housing pipe complete all as specified and directed 93 Material and labour for MS clamps made out of flat iron 125mmx12mm and 01 metre long with nut, bolts of 22mm dia of suitable length for 350mm bore housing pipe complete all as specified and directed 94 Material and labour for mild steel structural steel E-250 grade 410W (ISMB-150) fixed independently without connecting plateincluding two coats of black paint over a coat of red oxide complete all as specified and directed 95 Material and labour for Strata sample box, made out of 1st class soft wood (deodar) having appropriate internal dimensions 1000mm×600mm×100mm with open-able glass shutter using 4mm thick plain sheet glass having pigeon holes as approved, 2 Nos butt hinges of suitable size and 75mm long hasp staple 01 No having not less than 25 compartments capable of holding 480 to 540 grams of strata sample, including painting wooden surfaces with two coats of synthetic enamel paint (grey) over a coat of pink primer complete all as specified and as directed 96 Material and labour for 10mm thick (structural steel should be Fe-290 (Grade-E-165) mild steel black plate of size 600mm dia & cut into two semi-circular equal parts with 350 mm dia hole in the centre complete all as directed by Engineer-in-Charge. 97 Material and labour for pea gravel of size 1.5mm to 4.5mm packed all around 350mm bore housing pipe and 250mm bore blind pipe, strainer pipe upto entire depth as required at site in newbore-well, complete all as specified and directed.Note:- For the purpose of measurement, gravel brought by the contractor shall be stacked properly at site & measurements of stack shall be carried out before use and after use(left unused) to arrive at the net qty of gravel used by the contractor in the work & payment against this item shall only be made for the qty of gravel used in the work not for the total qty of gravel brought. 98 Material and labour for testing and developing the bore well by means of aircompressor5000 PSItill sand free clear water discharge is obtained to achieve maximum yield of suitable capacity for first 24 hours running complete all as specified and directedNote : All equipments shall be arranged by contractor athis own cost. 99 All as per Srl item No. 11.23 here-in-before but beyond 24 Rs. 100 Material and labour for yield testing of the tube well by means of engine driven pumping set of suitable capacity, the discharge shall be measured by providing orifice system or ‘V’ notch fixed to steel tank of adequatecapacity complete all as directed by Engineer-in-Charge. Note : All equipments arranged by contractor at his cost & rates are deemed to be included in quoted rates. 101 Testing portability of water by chemical analysis such as PH Value, dissolved solids, hardness as CaCo3 and Calcium, Magnesium, Chlorides, sulphate, nitrate, alkality, Iron Turbidity NTU, mineral oil, colour hazen units, taste, odour, residual free chlorine, total Coliform per 100mm (microbiological test) and E Coli as per 100ml (microbiological test) as well as bacteriological portability from any Govt lab complete all as directed by Engineer-in-Charge. 102 Supply, installation, commissioningand testing of submersible pump set V-8Multistage (As per mfg design stage ( min 4 stage)) electric driven 2900 RPM of capacity not less than 780 LPM at not less than 90mtr head water lubricated suitable for 200/250mm bore and 150 mm dia discharge pipe coupled with squirrel cage induction electric motor 3 phase 415 volts of capacity not less than 30 HP having CI casing & Gun Metal impeller fitted with delivery pipe etc as reqd at sitewith suitableelectric motor, B class insulation, IP-68 Protection and electric connection With following MOC: Stainless Steel Impeller, Stainless Steel Pump Shaft, LTB Pump Bushes, Cast Iron Bowl/Stage Casing; complete all as directed by Engineer-in-Charge. 103 Supply and fixing Flat Submersible cable PVC multi-stranded copper conductor 3 core 16 sqmm from LT Panel/ star-delta starter to pump motors complete all as directed by Engineer-in-Charge. 104 Supply and fixing mild steel Columnpipe heavy duty5.4 mm wallthickness 100 mm dia in 3 m length includingflanged both side including provision of nuts, bolts, gasket etc including lowering and fixing complete all as directed by Engineer-in-Charge. 105 Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, indoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts,Front & Rear openable double door with locking arrangement. The panel board shall be made of 2.0 mm thick CRCA/MS sheet (Min size 1.2 m x 1.0 m x 0.45 m) with Synthetic enamel Paint both side.The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm ,gaskets thimbles including cable entry glands, all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregatescomprising of following:-(i) Panel having common aluminium bus bar of capacity 400 Amp TPN each ( Size 40mm x10 mm) and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size(ii) INCOMING(a) (a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 200 Amp 4 Pole ICU= 36 KA with overload variation 40-100%- 01 No(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 Amp 4 Pole ICU = ICS = 16 KA- 01 No.Make : ABB/SIEMENS/SCHNEIDER.(outgoing)(b) MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole ICU = ICS = 16 KA- 01 No.Make : ABB/SIEMENS/SCHNEIDER.(outgoing)(c) MCB TPN 63 Amps -01 Nos(d) ON LOAD Change over switch 200 Amps -01 No(e) Automatic star delta submersible starter DLX (with short circuit protection) HGS series suitable for 30-35 HP motor provided with protection degree IP-54 and FRLS internal wiring and extended wide bend coil and in-built metering and contactor size is MN 50 and Overload relay Range 28 A-40 A and TP MCB rating 100 Amps and Starter should be provided with Single phase preventer etc all as directed.(iv) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No(v) Ammeter 0 - 200 Amps digital type square shape 96mm flush mounted with selector switch and CTs 200/5 A - 1 No.(vi) Indicator lamp RYB : 01 Set, with Suitable CT Coil complete 106 Supply, installation and testing of Heavy duty Chemical Dosing system plunger type suitable to inject solution upto 25 LPH, working pressure 10 kg /cm square comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP,1440 RPM assembled with agitator in one motor , agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty panited with MS fabricated frame duly anticorrosive paint, with Chemical grade PVC NRV including inlet /outlet check valve all connections ,connecting CPVC/UPVC/PVC Fittings ,Pipe etc complete all as required at site and as directed by Engineer-in-Charge. 107 STP WORKS 108 Design, Supply, construction, installation, testing & commissioning of Sewage Treatment Plant 100 KLD based on principle of aerobic attached growth non-clogging randomly Moving Bed Bio-reactor (MBBR) prefab type, including required foundations and & covering of all motors with MS sheets covers & the following :-(a) One no. Fine bar screen chamber fitted with screen of MS epoxy construction as per given minimum specifications, to be installed in Fine Barscreen chambers, provided at an angle of 60° to prevent floating objectspassing through it and subsequently removing manually and dumped forfurther disposal(b) One No. Oil & Grease Removal Chamber in RCC construction with design mix concrete of grade M-30, for removal of free floating Oil & Grease in the sewage, as per given specifications(c) One No. Equalisation tank in RCC construction with design mix concrete of grade M-30, as per given specifications, to cater for the peak discharge including provision of diffused air to ensure that septic conditions do notoccur in tank at all. One lot of air grid for equalization tank for providingaeration in the tank, as specified in PS.(d) Two Nos. raw sewage pumps complete with motor and all necessaryaccessories and fittings, to be installed for transferring sewage fromequalization tank to process reactor. Level sensor should be provided in the tank and interlinked with pumps for ON-OFF operation as per water level in the tank. One pressure gauge for each pump has to be provided to measure pressure at the outlet.(e) Two nos. Air blower complete with motor and all necessary accessorieSupply and fixingittings, for providing air in equalization tank, MBBR reactors & Sludge holding tank. One no. Air rotameter is to be provided in each line to MBBR reactor 1 & 2, & EQT for measurement of quantity of air.(f) One lot of anoxic chamber in MSEP construction with internals comprising of media and MSEP Mixer. 109 (g) Two lot of MBBR Tank in MSEP construction with internals comprising of media, SS air grid & SS rise pipe, media retaining sieves, etc.(h) One Lot of Tube settler tank in MSEP construction with internals comprising of media, supporting structure & collection trough.(j) Two Nos. sewage centrifugal mono-block self-priming recirculation pumps complete with motor and all necessary accessories and fittings. One pressure gauge for each pump is provided to measure pressure at the outlet.(k) One No. Chlorine Contact cum Filter feed tank in in MSEP construction, as per given specifications. With one set of chlorine dosing system comprising of solution tank and dosing pumps, as specified in PS, with necessary connection for dosing of solution in chlorine contact tank.(l) Two Nos. filter feed centrifugal monobloc pumps complete with motor and all necessary accessories and fittings for feeding tertiary unit, Level sensor should be provided in the chlorine contact cum filter feed tank andinterlinked with pumps for ON-OFF operation as per level in the sump. Onepressure gauge for each pump is provided to measure pressure at theoutlet(m) One No. Dual Media filter, complete with media, frontal piping, valve andpressure gauges to measure pressure across the filter.(n) One No. Activated Carbon Filter of, complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter(o) One No. Treated Water tank in MSEP construction, to receive supernatant coming from tertiary treatment plant, as per given specifications(p) Two Nos. sludge transfer self-priming mono-block pumps complete with motor and all necessary accessories and fittings. One pressure gauge for each pump has to be provided to measure pressure at the outlet 110 (q) One No. Continuous feed sludge screw press with dosing system for sludge dewatering system as specified in PS(r) One No. MCC Panel for operation of all electromechanical units of sewage treatment plant(s) One lot of suitable size Piping & valves of suitable material to interconnect various units as per site layout.(t) One lot of Power & control cables to interconnect various drives and instrumentations with STP panel.(u) One lot of foundations in PCC for all E&M equipment, as required.Note :The prices for Design, Supply,construction, installation, testing and commissioning of 100 KLDSTP based on MBBR technologyincluding all civil, electromechanical andinstrumentation works as per thespecifications given in technical specification including requiredfoundations. 111 Supply and fixing of Non Clog Centrifugal sewage pump having 20 mtr Head, Capable of delivering approx. 937.5 LPM at 20 mtr Head with 10 HP AC Electric Motor 3 Phase, 415V, 50C/S, 1450RPM directly coupled on a common base frame complete all as directed by Engineer-in-Charge. Make: Kirloskar/ KSB/ Crompton 112 Supply and fixing cast iron foot valve flanged end conforming to IS 4038 PN 0.2, 100 mm (4”) dia size all as specified and directed 113 Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, indoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts,Front & Rear openable double door with locking arrangement. The panel board shall be made of 2.0 mm thick CRCA/MS sheet (Min size 1.2 m x 1.0 m x 0.45 m) painted with Synthetic enamel Paint both side.The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm, gaskets thimbles including cable entry glands, all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL& 1/2 mtr Below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregatescomprising of following:-(i) Panel having common aluminium bus bar of capacity 400 Amp TPN each ( Size 40mm x10 mm) and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size(ii) INCOMING(a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 Amp 4 Pole ICU= 16 KA with overload variation 40-100%- 01 No(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole ICU = ICS = 16 KA- 02 Nos (c) MCB SPN 32 Amps -01 No(d) ON LOAD Change over switch 100 Amps -01 No(e) Automatic star delta submersible starter ASD (with short circuit protection) HSG series suitable for 10-12.5 HPmotor provided with protection degree IP-54 and FRLS internal wiring and extended wide bend coil and in-built metering and contactor size 18 and Overload relay Range 8 A-12 A and class H Insulation and Starter should be provided with Single phase preventer etc all as directed.(iv) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No(v) Ammeter 0 - 200 Amps digital type square shape 96mm flush mounted with selector switch and CTs 200/5 A - 1 No.(vi) Indicator lamp RYB :01 Set. with Suitable CT Coil complete 114 Outsourcing of Manning / Operation & routine periodical maintenance of electro -Mechanical equipment’s, control valves, instrumentals etc of STP 100 Cum/day (for Two shifts per day including Sunday & holiday, by employing One FGM (Semi skilled operator) and One helper per Shift (each shift of eight hours) and maintaining desired level of BOD/COD, TSS, TKN by dosing of required quantity of chemicals as per OEM recommendation complete for a period of 11 months starting from the next day of certified date of completion of Phase-I (to be intimated by GE through Work Order separately) complete all as specified and directed.Note :- (a) Maintenance of log sheet and all maintenance records shall be responsibility of the contractor and no stationary shall be provided by the Department. Format of log sheet and records etc shall be decided by GE/ Engineer -in-charge(b) The contractor is responsible to maintain the installations and surrounding area in presentable manner through out the period. The shift timings shall be decided by Engineer- in- charge and liable to change as and when required by Engineer- incharge.(c) Area cleaning surrounding the plant room & inside the plant room etc shall be responsibility of the contractor (d)The contractor shall be maintain clear record of attendance for workmen/ staff. (e) Consumables i.e grease, lubricant oil, cotton waste washers etc required for routine maintenance of STP shall be provided by contractor and cost of the same shall be deemed to be included in unit rates quoted.(f) Cost of stationary required for attendance register, meter readings, site order books, log sheets etc shall be provided by contractor and cost of same shall be deemed to be included in unit rates quoted by contractor.(g) FGM/ Operator should be ITI qualified in respective trade i.e. electrical/ fitter and having minimum 2 years experience in similar trade/ works.(h) Helper should be having 2 years experience in similar trade(j) Timing of shift shall be as decided by Engineer-in-Charge and as specified . 115 TREATED SEWAGE WATER SUPPLY WORKS 116 Supply and fixing 3 phase horizontal, radially split volute casing centrifugal pump 3 HP in back pull out design, single stage, single entry with radial impeller equipped with VFD devices & equipped with speed control panel to control speed/ discharge pump set capacity of discharge 500 LPM at delivery head of 22mtr of IE 3* & with MOC material CI/ bronze with suitable electrical panel, cable & starter complete all as directed by Engineer-in-Charge. 117 Supply and fixing motor starter for 3 HP pumping sets, centrifugal, electric driven having extended wide bend, coil, FRLS internal wiring, providing with protection degree IP 54, starter type air break, class H insulation complete all as directed by Engineer-in-Charge. 118 Supply and fixing PPR gate valves (brass insert) of 160mm bore complete all as specified and directed 119 Supply and fixing PPR gate valves (brass insert) of 75mm bore complete all as specified and directed 120 Supply and fixing cast iron air valve with single air outlets, conforming to IS : 14845 of size 50mm bore and fixing up in cast iron water supply mains of size 100mm bore complete all as specified and directed 121 Supply and fixing cast iron air valve with single air outlets, conforming to IS : 14845 of size 50mm dia and fixing up in cast iron water supply mains of size 150mm dia complete all as specified and directed
Contract Date: Mar 29, 2023 Contract Value : 30.66 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
21.
Defence #1528452 AOC
Tender For Special Repairs To Stp At Lal Phatak Bareilly Cantt Under Ge ( E ) Bareilly -Demolition / Dismantling Ofrcc Beam , Chajja , Shelve, Drain Covers And Similar Work Complete All As Specified And Directed. 2 Dismantling Asbestos Cement ( Corrugated, Semi Corrugated Etc ) Sheets In Roofcoveringscomplete All As Specified And Directed. 3 Dismantling Posts Or Struts ( Wood, Steel Or R.C.C. ) Any Section, Including Taking Out Embedded Portion And Making Good Disturbed Ground Complete All As Specified And Directed. 4 Dismantling Fillets, Rails, Posts, Rafters, Purlins, Etc. Under 40 Sq. Cm In Section Complete All As Specified And Directed. 5 Taking Down Shutter Of Any Description Exc. 1 Sqm But N.Exc 2 Sqm Each And Removing From Site Complete All As Specified And Directed By Engineer-In-Charge. 6 Demolition Of Cement Concrete ( Un-Reinforced ) And Paving N.Exc 15 Cm Thick ( Below Or Above Ground Level ) Complete All As Specified And Directed. 7 Taking Down Cement Plaster Of Any Description On Brick Or Stone Wall Etc Including Racking Out Joints Hacking For Key Scrubbing Down With Water Etc Complete All As Specified And Directed. 8 M & L For Applying Cement Slurry Over Existing Roof Surface @ 3 Kg / Sqm Complete All As Specified And Directed. 9 M&L Screed Bed Or Bedding Layer Of Mortar, 15 Mm Thick, In Cement Mortar 1:4, Over Rcc Roof Slabs For Laying Water Proofing Treatment Mixed With Using Water Proofing Liquid @ 150 Ml Per Bag Of Cement Complete All As Specified And Directed By Engineer-In-Charge 10 Supply And Fix App Polymeric Water Proofing Membrane, Minimum 3 Mm Thick And Minium Weight 3 Kg Per Sqm Tochshield Membrane / Equivalent With Rich Bitumen And Select Polymers Blended Together To Obtain Excellent Heat Resistance & Cold Resistant, Black Finish Reinforced With Non-Woven Polyester Matt, With A Thermo Fusable Finish Laid Over Compatible Bitumen Primer Torching Overlaps With A Propane Or A Butane Gas Torch, With A Overlap Of 100 Mmand Sealing Including Applying A Coat Of Cold Emulsion Bituminous Primer All As Per Manufacturer’S Instructionscomplete Incl Removal Of Existing Treatment All As Specified And As Directed.Note: ( I ) Coved Fillets In Pcc ( 1:2:4 ) Type B-0 Using 12.5Mm Graded Stone Aggregate With Using Water Proof Chemical , Of Radius 75Mm Shall Be Provided At The Junction Of Roof And Parapet Wall / Mumty / Chimney / Other Vertical Surfaces And Thereafter Surface Painted With Hot Paving Bitumen Of Grade 85 / 25 Confirming To Is-73, [email protected] Kg / Sqm Over A Coat Of Bituminous Primer Confirming To Is-3384 Applied @ 0.30 Kg / Sqm ( Ii ) Polymeric Membrane Shall Be Taken To A Height Of 45Cm ( Minimum ) And Then Inserted Inside The Groove Of Parapet Wall Of Brick Masonry And Shall Be Finished By A Membrane Flushing. ( Iii ) The Waterproofing Treatment Shall Be Got Carried Out By The Manufacturer Or Their Authorized Applicators. ( Iv ) In Case Of Stone Masonry Parapet Wall Etc A Groove Of Size 25Mmx25mm ( Minimuim ) Shall Be Made In Coved Fillet At The Junction Of Roof And Parapet Wall / Mumty Chimny / Other Vertical Surfaces And Polimeric Membrane Insterted In Groove And Sealed With Paving Bitumen. ( V ) Exposed Surfaces Of App Membrane Shall Be Applied With Two Coat Of Bituminous Aluminium Paint @ 150 Ml / Sqm. ( Vi ) Above Aspects Are Deemed To Be Included In Quoted Rate. 11 Rolled Sections As In Main And Cross Beams, Hip And Jack Rafters; Purlins, Vertical Post Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Complete All As Specified And Directed. 12 S & F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Of An Colour Having Tensile Strength Of 550Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed. 13 M&L For Ms Work As In Clamps, Hold Fast, Wall Ties, Hooks, Angle Cleat And Similar Small Articles Confirming To Fe290 Gde E-165 Complete All As Specified And Directed. 14 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plainsteel Sheet 0.50Mm Of An Colour Having Tensile Strength Of 550Mpa As In Ridge, Fixed With Self Tapping Screws Complete All As Specified And Directed. 15 M&L 100 Mm Cement Concrete Type B- 2, 1:2:4 ( 40Mm Gradedaggregate ) In Sub-Floors, Sub-Bases, Floors And Pavings And Finishing Cement Concrete Surface Even And Smooth Complete All As Specified And Directed. 16 S&F For 40 Mm Thick Factory Madeflush Shutters, Solid Core Construction, With Block Board Core And Plywood Face Panels, Commercial Type On Both Sides Complete All As Specified And Directed . 17 S&F 30 Mm Thick Factory Made Both Side Prelam Pvc Sheet Used Instead Of Plain Colour Pvc Sheet. Stile And Rails Feathered At Edges Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails, M.S. Frame Shall Be Covered With Heat Moulded Palin Colour Pvc `C Channel Heaving Apanelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S Frame Wedded / Sealed To The Stiles, & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing. Complete All As Specified And Directed. 18 S & F In Repair 300 Mm Long Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section And Fixed Complete All As Specified And Directed. 19 S & F In Repair 150 Mm Thick Aluminium, Anodised, Barrel Tower Bolts Of Extruded Section And Fixed Complete All As Specified And Directed. 20 S&F In Repair 150Mm Size Aluminium Handles, Cast Type Anodised Completed All As Specified And Directed. 21 S&F In Repair300 Mm Long Mild Steel Sliding Door Bolts Plate Type Stone Enamelled Black With Bright Bolt Not Less Than 16 Mm Dia With And Including A Minimum Of 6 Bolts And Nuts, 04 Nos On Bolt Plate And 02 Nos On Staple Plate And Fix Complete All As Specified And Directed 22 S&F In Repair Stainless Steel Wire Cloth, 0.56 Mm Nominal Dia Of Wire And Average With Of Aperture 1.18 Mm And Fixed With Stainless Steel Wire Staples Complete All As Specified And Directed By Engineer-In-Charge. 23 Hacking Outold, Broken Glass ( Any Thickness, ) Size Quality Or Description ) From Metal Frames Incl.Punching Or Drilling Out Old Glazing Pins / Spring Clips And Fixing New Ones Incl M&Lin Repairfor 3Mm Thick Sheet Glass Ordinary Qualityand Glazing With Oil Putty In Squares Not Exc. 0.5 Sqm In Each Pane Complete All Specified And As Directed. 24 M& L For Rendering 15Mm Thick In Cement Mortar ( 1:4 ) , On Fair Face Of Brick Wall, Finished Even & Smoothwith Using Water Proofing Liquid @ 150 Ml Per Bag Of Cement Complete All As Specified And Directed. 25 M&L Rendering 15 Mm Thick In Cm ( 1:6 ) On Brick Masonary Wall Surfaces Or On Other Than Fair Faces Of Brick Masonry Finished Even And Smooth Witout Using Extra Cement Complete All As Specified And Directed. 26 M & L Pcc ( 1:2:4 ) Type B1 Using 20Mm Graded Stone Aggregate As In Staging Base For Motors Including Necessary Form Work And Finishing All Exposed Surfaces Of Concretecomplete All As Specified And Directed. 27 M &L 100 Mm Thick Pcc ( 1:4:8 ) Type D2 Using 40Mmagg As In Sub Base Complete All As Specified And Directed. 28 M&L For Coloured Glazed Interlocking Machine Pressedcement Concrete Factory Madepaver Block Any Shape And Size Confirming To Is 15658 -2006 Of100mm Thickness, M-50 Grade, Machine Pressed Of Pattern And Colour As Approvedcomplete All As Specified And Directed. 29 M&L For Machine Pressed Precast Cement Concrete Factory Made Glazed Kerb Stone Of Size 300X100x450 Mm Pcc ( 1:2:4 ) Type B 0 Using 12.5 Mm Graded Stone Agg , Jointed In Cm 1:4 Including Excavation And Removing Complete All As Specified As Directed 30 M&L Sand Filling Under Floors Or In Foundations Including Watering And Consolidation Complete All As Specified And Directed. 31 M&L For Rcc ( 1:2:4 ) Type B-1 ( Using 20Mm Graded Stone Aggregate ) As In Beams, Cantilevers, Bressummers, Lintels & Wall Band Over 1.5M Span Etccomplete All As Specified And Directed. 32 M&L For Rcc ( 1:2:4 ) Type B-1 ( Using 20Mm Graded Stone Aggregate ) As In Chajja, Beams Etccomplete All As Specified And Directed. 33 M & L For Precast Reinforcement Cement Concrete ( 1:2:4 ) Type B1 Using 20Mm Graded Stone Aggregatein Landings, Cover Slabs ( For Manholes, Septic Tanks Etc. ) Complete With Joints To Match, Complete All As Specified And Directed 34 M&L For Mild Steel Tmt Bar10mm Dia And Overcut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Bindingmild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clipscomplete All As Specified And Directed. 35 All Asitem Srlno.34 Above, But 6Mm To 8Mm Dia Bars Complete All As Specified And Directed. 36 Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelvesincluding Sup- Ports, Overhangs, Etc. Also Splaysbetweenfloors And Beams, Etc Complete All As Specified And Directed. 37 M&L Preparation Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coats Of Synthetic Enamel Paint Complete All As Specified Anddirected. 38 M&L For Preparation Of New Untreated Wooden Or Wood Based Surfaces Of Any Description Not Otherwise Described Over 10 Cm Width Or Girth And Applying Two Coat Of Synthetic Enamel Paint Over And Including One Coatof Pink Primer Complete All As Specified And Directed By Engineer-In-Charge. 39 M&L For Preparation Of Old Wooden Or Wood Based Surfaces Of Any Description Not Otherwise Described Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed. By Engineer-In-Charge. 40 M&L For Complete Removal Of Existing Treatment On Wall By Scrapping With Mechanical Sander ( Having Mechanical Vaccum Mechanism ) With Sanding Pad Of Appropirate Grit To Make Surface Clean, Free From Dust , Loose Paintetc By Skilled Labourand Applying Oftwo Coat Obd On Wall With Airless Electric Sprayers Over A Coat Of Primer Applied Using Airless Electric Sprayers Over Two Coats Ofwall Care Puttyof 1 Mmthickness Prepared And Sanded With Finishes Shall Be Applied Using Airless Spray Technology And Capable Of Oprating Single Spray Gun With A Suitable Hose Length. The Spray Machine Should Be Reputed Manufacturer With Pro-Guard Technology And Capability Of Tracking Pressure As Well Paint & Primer Usage, Complete All As Specified And Directed. 41 M&L Forapplying Oftwo Coat Obd On Newly Plastered Surface Of Wall With Airless Electric Sprayers Over A Coat Of Primer Applied Using Airless Electric Sprayers Over Two Coats Ofwall Care Puttyof 1 Mmthickness Prepared And Sanded With Finishes Shall Be Applied Using Airless Spray Technology And Capable Of Oprating Single Spray Gun With A Suitable Hose Length. The Spray Machine Should Be Reputed Manufacturer With Pro-Guard Technology And Capability Of Tracking Pressure As Well Paint & Primer Usage, Complete All As Specified And Directed. 42 M&L For Complete Removal Of Existing Treatment On Ceiling, Etc Including Cleaning Of Any Mortar Drops, Fungus Efflorescent Salts Etc And Preparation Of Old Plastered Surfaces And Applying Two Coats Ofwhite Wash Complete All As Specified And Directed. 43 Demolition Of Brickwork Or Stone / Boulder Masonry, Built Incement Mortar Including All Quoins, Pillars, Etc, Complete All As Specified And Directed. 44 M&L For Brick Work With Fly Ash Bricks, Straight Or Curved On Plan Exc. 6 M Mean Radius, Built In Cm ( 1:6 ) Complete All As Specified And Directed. 45 M&L For Preparing Old Plastered Walls Surfaces And Applying Two Coats Of Cement Base Paint Over A Coatofprimerwith Finishes Shall Be Applied Using Airless Spray Technology And Capable Of Oprating Single Spray Gun With A Suitable Hose Length. The Spray Machine Should Be Reputed Manufacturer With Pro-Guard Technology And Capability Of Tracking Pressure As Well Paint & Primer Usage, Complete All As Specified And Directed. 46 M&L For Preparing Newly Plastered Walls Surfaces And Applying Two Coats Of Cement Base Paint Over A Coatofprimer With Finishes Shall Be Applied Using Airless Spray Technology And Capable Of Oprating Single Spray Gun With A Suitable Hose Length. The Spray Machine Should Be Reputed Manufacturer With Pro-Guard Technology And Capability Of Tracking Pressure As Well Paint & Primer Usage, Complete All As Specified And Directed. 47 Preparation Of New Steel Surfaces Exc 10 Cm Width Or Girth And Applying Two Coats Of Syntetic Enamel Paint Overone Coat Of Red Oxide Of Zinc Chrome Primer Complete All As Specified And Directed. 48 Excavating In Trenches N. Exc. 1.5 M Wide, And N.Exc. 1.5 M In Depth For Foundation Etc. N.Exc. 10 Sqm On Planand Getting Out Soft / Loose Soil Complete All As Specified And Directed. 49 Removing Excavated Material N. Exc. 50 Mtr And Depositing Where Directed At A Level N. Exc. 1.5 Mtr Above The Starting Point. 50 Returning Filling In, Including, Spreading, Levelling, Watering And Well Ramming In Layers N. Exc. 25 Cm Complete All As Specified And Directed. 51 M&L Pcc ( 1:4:8 ) Type D2 Using 20Mm Graded Agg As In Foundation Mass Concrete Complete All As Specified And Directed. 52 Dismantling Fencing Wire Mesh, Any Type And Size Complete All As Specified And Directed. 53 Excavating In Post Holes ( Or Similar Holes ) In Soft Soil Each N. Exc. 0.5 Cum, Gettting Out, Returning Fillingin And Rammingearth Or Broken Rubble Mixed With Earth Around, In Layers N. Exc. 25 Cm, Watering And Removing Surplus Soil To A Distance N Exc. 50 Mtr And Making Good Surface Complete All As Specified And Directed. 54 M &L Pcc ( 1:3:6 ) Type C2 Using 40Mmagg As In Post Holes / Mass Concrete Complete All As Specified And Directed. 55 S&F Angle Iron Fencing Post And Struts Including Cutting Tops To Shape As Directed Drilling Holes, Notching For Wire Etc, Flat Iron Fillets, Plain Bars ( For Securing Wire Mess Etc ) Including All Necessary Drilling, Bolting Or Riveting Etc And Similar Work Conforming To Fe 410-0 Or Fe 310-0 Including Round Bars Etc Complete All As Specified And Directed. 56 Supply Only Chain Link Ms Galvanisd Fencing, Any Size Or Type Complete All As Specified And Directed. 57 Fixing Only Chain Link Fencing Including Linewires, Steel Bars, Any Mesh, Sizeand Type To Any Type Of Standards, Rails, Straining Bolts, Etc. Including Provission Of Binding Wire Complete All As Specified And Directed. 58 Mild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other, Orscrewedboth Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, The Length Of Bolt Exc 5Cm But N Exc 10Cm Complete All As Specified And Directed. 59 Supply Only Mild Steel Flat, Roud Bar Or Squre Barin Available Length Of Fe-290 ( Gde E-165 ) Complete All As Specified And Directed. 60 S&F Galvanised. 2 Strand, Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacings And Straining And Fixing To Any Type Of Standard Rails Strain- Ing Bolts, Including, Securing Or Tying At Crossings With And Provision Of Galvanised Mild Steel Wire, Staples Or Steel Pins, Etc. Complete All As Specified And Directed. 61 S&F Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering, Doo0rs Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings And Fastening And Fixing Complete Fe 290 Gde E-165 Complete All As Specified And Directed. 62 Preparing Of New Steel Surfaces Of Any Description, N.Exc 10Cm Girth When Unconnected And Applying Two Coats Of Syntetic Enamel Paint Overone Coat Of Red Oxide Of Zinc Chrome Primer Complete All As Specified And Directed. 63 M&L, 3-Layer Pp-R Polypropylene Random Copolymer Pipes Sdr 7.4 & Sdr 11Uv Stablised And Antimicrobial Fusion Welded Having Thermal Stability Forwater Supply All Pp-R Plain & Brass Threaded Polypropylene Random Fittings And Fixtures Such As Bends, Tees, Elbows, Reducers, Unions, Plugs & Sockets Etc., Laid In Trenches, Of 75Mm Dia With Allcomplete All As Specified And Directed. 64 All As Srl Item No. 63 Above, But Of Size 50Mm Complete All As Specified And Directed. 65 All As Srl Item No. 63 Above, But Of Size 32 Mm Complete All As Specified And Directed.Note For Item No. 63 To 65 : Excavation And Earth Work Shall Be Measured And Paid Separately. 66 M & L For Making Connection Of Pp-R Distrubution Branch With Pp-R Distrubution Branch With Pp-R Main Of 50 To 75 Bore Of Pipes In Mm By Providing And Fixing Tee Including Cutting And Making Fusion Joint Etec., Complete All As Specified And Directed. 67 M & L For Making Connection Of Pp-R Distrubution Branch With Pp-R Distrubution Branch With Pp-R Main Of 32Mmto 50Mmbore Of Pipes In Mm By Providing And Fixing Tee Including Cutting And Making Fusion Joint Etc., All As Specified And Directed. 68 Supply And Fixing , Sluice Valve, 80Mm Size, Non-Raising Type With Ci Wheel, Drilled Flanged Ends, Pn-1.6, Heavy Duty With Stainless Steel Spindle And Gunmetal Working Parts Including Flanged Jointing On Both Ends, Jointing Material Such As Rubber / Fibre Board Gasket, Suitable Size Bolts, Nuts And Twin Washers Compelete All As Specified And Directed. 69 All As Srl Item No. 68 Above, But Of Size 50Mm Complete All As Specified And Directed. 70 M&L, Construction Of Brick Masonry Valve Chamber Of Size 900X900x 900Mm ( Internal Dimensions ) With Pcc 1:4:8 Foundation 150Mm Thick, Brick Work Built In Cm 1:6, Pcc 1:3:6 Coping 50Mm Thick, Plastering 15Mm Thick In Cm 1:6 To All Internal And Exposed Surfaces Including Excavation Earthwork In Hard / Dense Soil, Ms Sheet Cover 4Mm Thick With Locking Arrangement Embedded In Pcc And Painting To Ms Cover With Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer Etc Complete All As Specified And Directed. 71 Supply & Fixing Non Return Valve Of 100M Dia Of Isi Markedwith Bolts, Nuts, Rubber Insertions Etc. Complete All As Specified And Directed. 72 Supply And Fixing Multisatge Centirfugal Pump Fortreated Water Transferof Haed 25 Mtr Flow Rate 20 Cub Mtr Per Hr Complete All As Specified And Directed. 73 Supply And Lay Cable Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of 4 Core 150Sqmmcomplete All As Specified And Directed. 74 Supply And Lay Cable Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of 4 Core 16Sqmm Complete All As Specified And Directed. 75 M&L For Cleaning And Desiiting Of Screen Bar Channel , Oil And Grease Trap And Equilization Tank Andremoving Allthe Deposited Sludge, Soil And Other Material From Mentioned Aboveincluding Bailing / Pumping Out Muddy Waterby Mechanically Or By Providing Suitable Pump Sets From Bottom Level Of Well, Scrapping Out The Scales / Deposits From Inner Surface Of The Well Throughly, Washing With Bleaching Powder And Soda Ash, Cleaning / Bailing Out Settled Materials Completely By Any Means And Removing Sludge To A Distance Up To 3 Km Out Side Of Defence Land Limit And Dispose Off In Low Lying Area Including Dewatering As Required Including Writing Tank Cleaned On ...... ( Date ) With 10 Cm Size White Letter On Black Surface By Engaging Skilled Artist Using First Quality Synthetic Enamel Paint Complete All As Specified And Directed. Note:- ( I ) Contractor Is To Arrange Own Diesel Pump, T&P Etc For Cleaning Purpose And Minor Spares And Consumable Like Small Screws, Washers, Cleaning Agents Consumables Etc Is Deemed To Be Included In The Cost, The Unit Rate Quoted Deemed To Be Include All Safety Precautions To Be Taken While Working In Lift Well. ( Ii ) The Accumulated / Deposited Sludge After Drying Shall Be Disposed Offoutsidethedefence Landtoadistance Exceeding1.5 Km And Notexceeding 5.00Km Fromthe Lift Wellcost Of Which Shall Be Deemed To Inclusive In The Quoted Rate And Nothing Extra Shall Be Paid On This Account. ( Iii ) Before Commencement Of Work, Necessary Arrangement For Disposal Of Sewage / Sludge Be Made And Work To Be Carried Out In Fast Pace By Deploying More Man Power At Lift Well In Order To Complete The Work At The Earliest. 76 Dewateringandpumpingoutofexistingaccumulatedsewage / Sludgeat Stp Lal Phatakat Bareilly Cantt Fromtube Settler Tankby Manullay Or Using External Sewage Disposal Pump Sets To Near By Sewagedisposaldrainandcleaningof Tanksby Scrapping With Wire Brush Or Any Other Means On Walls And Bottom Of Tank And Removing The Sludge / Silt / Sand / Fungus Etc Deposited Inside The Sumps / Tanks With Buckets And Depositing Where Directed, Including Removing / Replacement Of Duck Media And Followed By Cleaning With Bleaching Water Solution And Fresh Water And Finally Applying One Coat Of Snow Cem On Internal And External Surfaces Including Writing The Date Of Cleaning And Due Date Of Cleaning In White Colour On Black Background On External Walls Complete All As Specified And Directed.Note:- The Followings Are Deemed To Be Included In The Rate Quoted:- ( I ) The Disposal Of Accumulated / Deposited Sludge After Dryingoutsidethedefence Landtoa Distance Exceeding1.5 Km And Notexceeding 5.00Km Fromthe Stp. ( Ii ) Before Commencement Of Work, Necessary Arrangement For Disposal Of Sewage / Sludge Bemade And Work To Be Carried Out In Fast Pace By Deploying More Man Power At Stp In Order To Complete The Work In Max 02 Days. ( Iii ) Refixing Of Old Serviceable Deckmedia. ( Iv ) Cutting And Rewelding Of Supporting Ms Frame Structure. ( V ) Replacement Of Unsv Rusted Portion Of Supporting Ms Frame Structure.Cost Of Ms Fame Will Be Paid Saperetly 77 Dewateringandpumpingoutofexistingaaccumultate Sewage From Mbbr I And Mbbr Ii Tank Mechanically Or Using External Sewage Disposal Pump Sets To Near By Sewage Disposal Drain And Cleaning Of Tanks By Scrapping With Wire Brush Or Any Otyer Means On Walls And Bottom Of Tank And Removing The Sludge / Slit / Sand / Fungus Etc Deposited Inside The Sumps / Tlanks With Buckets And Depositing Where Directed , Followed By Cleaning With Bleaching Water Solution And Fresh Water And Finally Applying One Coat Of Snow Cem On Internal And External Surfaces Including Writing The Date Of Cleaning In White Colour On Black Background On External Walls Complete All As Specified And Directed Including Two Coats Of White Washinternally And Externally Complete.Note:- ( I ) The Disposal Of Accumulated / Deposited Sludge After Dryingoutsidethedefence Landtoa Distance Exceeding1.5 Km And Notexceeding 5.00Km Fromthe Stp. ( Ii ) Before Commencement Of Work, Necessary Arrangement For Disposal Of Sewage / Sludge Bemade And Work To Be Carried Out In Fast Pace By Deploying More Man Power At Stp In Order To Complete The Work In Max 02 Days. ( Iii ) Refixing Of Old Serviceable Deckmedia. ( Iv ) Cutting And Rewelding Of Supporting Ms Frame Structure. ( V ) Replacement Of Unsv Rusted Portion Of Supporting Ms Frame Structure.Cost Of Ms Fame Will Be Paid Saperetly. 78 M&L For Replacement Of Filteration Media Of Six Drying Bed With Sand And Stone Gravels ( A ) Natural Graded Gravels Of Size 20Mm To 25 Mm 150 Mm Layer ( B ) Natural Graded Of Size 15 Mm To 10Mm- 100 Mm Layer © Natural Gradede Graves Of Size 10 Mm -6Mm- 100 Mm Layer ( D ) White Graded Coarse Quartz Sand 8+ 14 Mesh- 100 Mm Layer ( E ) White Graded Coarse Quart Sand Of 16+30 Mesh 600 Mm Layer All As Specified And Directed. 79 Dewateringandpumpingoutofexistingaccumulatedsewagefromchlorine Contact Tank , Drying Bed And Treated Water Tank By Mechanically Or Using External Sewage Disposal Pump Sets To Near By Sewagedisposaldrainandcleaningof Tanksby Scrapping With Wire Brush Or Any Other Means On Walls And Bottom Of Tank And Removing The Sludge / Silt / Sand / Fungus Etc Deposited Inside The Sumps / Tanks With Buckets And Depositing Where Directed, Followed By Cleaning With Bleaching Water Solution And Fresh Water And Finally Applying One Coat Of Snow Cem On Internal And External Surfaces Including Writing The Date Of Cleaning And Due Date Of Cleaning In White Colour On Black Background On External Walls Complete All As Specified And Directed.Note :- The Followings Are Deemed To Be Included In The Rate Quoted:- ( I ) The Accumulated / Deposited Sludge After Drying Shall Be Disposed Offoutsidethedefence Landtoadistance Exceeding1.5 Km And Notexceeding 5.00Km Fromthe Stpcost Of Which Shall Be Deemed To Enclusive In The Quoted Rate And Nothing Extra Shall Be Paid On This Account. ( Ii ) Contractor Is To Arrange Own Diesel Pump, T&P Etc For Cleaning Purpose And Minor Spares And Consumable Like Small Screws, Washers, Cleaning Agents Consumables Etc Is Deemed To Be Included In The Cost, The Unit Rate Quoted Deemed To Be Include All Safety Precautions To Be Taken While Working In Stp. ( Iii ) Before Commencement Of Work, Necessary Arrangement For Disposal Of Sewage / Sludge Be Made And Work To Be Carried Out In Fast Pace By Deploying More Man Power At Stp In Order To Complete The Work In Max 02 Days. 80 Supply Installand Commissioning Of Granular Chlorination Dosing Pump Of High Pressure Single Head Gear Motored Adjustable Dosing Pump Having Output Of Suitablefor 461 Kldand Adjustable High Pressure Of Up To 100 Psi ( 7 Kg / Cm2 ) Or More , Power Input 230 V, 50 Hz Self Priming With Nonmetalic With Connecting Nuts , Ferrules And With All Accessoriesincluding Lead, Tubing Connection Injection Check Valve Complete All As Specified And Directed. ( A ) Preparation Tank ( 300 Ltr ) ( I ) Water Inlet Line ( Ii ) Outlet With Strainer ( Iii ) Drain ( Iv ) Overflow ( V ) Conical Bottom For Sludge Deposition ( Vi ) Pot Hole With Cover ( Vii ) Level Gauge ( Viii ) Inspection Port ( Ix ) Agitator ( B ) Service Tank ( I ) Dosing Pump Inlet Arrangement ( Ii ) Drain ( Iii ) Overflow ( Iv ) Level Gauge ( V ) Inspection Port 81 Supply And Installing Commissioning And Testing Of Lt Panel Board Indoor Type Of Suitable Size Cpri Certified Factory Made Cubical Type Weather And Vermin Proof Fixed On Including Ventiliation And Louvers Arrangement Pcc ( 1:2:4 ) Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Of Required / Suitable Size And As Directed At Site With Angle Iron Frame Of Size 40X40x6 Mm, 3 Phase 4 Wire 415 Volts 50 Hz Fabricated Out Of 2 Mm Thick Ms Sheet Including Two Coats Of Synthetic Enameled Paint Over A Coat Of Primer Red Oxide And Keepng Adequate Working Space Inside Of The Box ( Outer Width Of The Box Not Less Than 45 Cm And Gap Between Bus Bar Not Less Than One Inch ) And Double Door Handle Including Locking Arrangement As Directed Before Manufacturing The Panel Including Dismantling Of Existing Unserviceable Lt Panel. The Drawing Of The Feeder Pillar Box Will Be Approved By Engr-In-Charge And The Same Have The Following Electric Controls :- ( I ) Mccb 200 Amp 36 Ka, 4 Pole, 415 Volts 50 Hz Adjustable Thermal & Magnetic Setting ( As Incomming ) -01 No ( Ii ) Mccb 63 Amp 25 Ka, 4 Pole, 415 Volts 50 Hz Adjustable Thermal & Magnetic Setting ( Asout Going ) -10 Nos ( Iii ) Dol Starter -05 Nos ( Iv ) Starter Delta - 04 Nos ( V ) Digital Type Volt Meter With Suitable Volts With Selector Switches. ( Vi ) Digital Type Volt Meter With Suitable Amps With Resin Cast Ct Of Suitable Amps And Selector Switch - 01 ( At Main Out Going ) ( Vii ) Led Indicating Lamp Assembly R, Y, B Phase As Per Site Reuirement. ( Viii ) Insulated Eposcy Coated High Conductivity Copper Bus Bar 600 Amps With Colour Code For Phase And Neutral Complete All As Specified And Directed. ( Ix ) S&F Wiring With Pvc Insulated Multistranded Copper Conductor Single Core Cable 6 Sq Mm ( Nominal Cross Sectional Area ) As Per Site Requirement Including Sutable Size Of Copper Lugs Etc All As Specified And Directed. - 01 No ( X ) S&F In Repairs Single Phase Preventer Direct Mounting Type With Suitable Relay Range. ( Xi ) Supply And Fix Over Load Protection Relay With Suitable Relay Range For Operation On 3 Phase, 415 V As Per Site Requirement. 82 M&L For Dismanting Of Old Unsv Air Blower And Supply, Installation Testing And Commisioning For Air Diffusion System Comprising Of : Air Blowers ( 1W+1S ) Capacity: Approx 350 M3 / Hr At 4500 Mmwc And Old Unsv Existing Air Blower Will Be Kept In Store Yard Of Age E / M Iii All As Specified And Directed. 83 S&F No Entry Board Of Size 200Mm X 650Mm Of Thickness 3 Mm Ms Plate Duly Painted On Both Sides Alongwith Necessary Fixing Arrangements For Pump House As Per Sample Complete All As Specified And Directed. 84 Supply Only Lt Rubber Insulation Mat For Pump House Of Size 1 Mtr X 3 Mtr Of Thickness 10 Mm As Per Sample Complete All As Specified And Directed. 85 Supply Only Ortho Tolidin Solution As 1000Ml / Bottle For Testing Of Dissolved Chlorine In Water Complete All As Specified And Directed 86 Supply Only Chlorine Testing Glass Test Tube Kit Complete All As Specified And Directed 87 Supplying Andfixingverticalinlinessrawwaterfilterfeedpumps Withci Volute Andss Impellarandwithstainlesssteelshaft, Mechanicalseal Andchrome Steelshaft Sleeve, Connectedtoa Tefcinduction Motorsuitablefor400 / 440 Volts, 1500Rpm, 3 Phase 50 Cyclesa.C.Supplyhavingip- 55Protectionenclosure. Completewithbaseframe, Vibration Eliminating Pads, Nutsandbolts, Pressuregaugeondeliverysideetc.Withsuctionstrainer ( Necessary Rcc Foundations As Per Requirement And As Per Instructions Shall Be Provided By The Agency ) Andtaking Out Of Old Unsv Existing Raw Water Pump Will Be Kept In Store Yard Of Age E / M Iii All As Specified And Directed.Raw Water Filter Feed Pumpscapacity :525Lph ( Each ) Head : 12 Meterpower : 7.5 Hp As Required With 100% Standby Pumps ( 2W+1S ) . 88 Supplying Andfixingc.I.“Y”Typesuctionstrainerwithstainlesssteelperforatedsheet Screen, Flangedendsinerinstalledoutsidewatertanks Complete All As Specified And Directed. ( Make:Leader / Zoloto / Kartaror Equivalent ) 89 Supply And Installations Of Pipping Grid Arrangement Ofstainless Steel 304 Of 32 Mmfor Oxidation In Equalization Tank As Well As Pipping Grid In Mbbr Tank Connected Withairdiffuserincluding All Necessary Arrangements Of Both The Blowers For Oxidationall As Specicfied And Direcetednote :- Air Diffuser Will Be Paid Seperatly 90 Supplying, Installing, Testing, Commissioningof Centrifugal Horizontal Filter Feedpumpscomplete In Ci Body& Ci Impeller With Motor, Pressure Gauge With Isolation Cock, Isolation Valve, Nrv On Delivery Line. Isolation Valve, Strainer At Suction. The Pump Shall Be Suitable For 415±10% Volts 3 Phase Ac Supply Andtaking Out Of Old Unsv Existing Filter Feed Pump Will Be Kept In Store Yard Of Age E / M Iii Complete All As Specified And Directed.Pumps -02 Nos. ( 1W + 1S ) Flow Rate ( Each ) - 525 Lpmhead- 25 - 30 M 91 S&F For Filtrationplantverticaldownflowmultigradepressuresandfilterinmswelded Construction Fabricated In Accordance With Is 2825 From Minimum 6 Mm Thick M.S. Plate On Shell Andminimum 8Mm Thick M.S.Plate Ondished Endsas Perapplicable Isstandards. Thefilter Shall Have : ( A ) One No Pressure Tight Manhole And At Least One No. Pressure Tight Side Hole For Maintenancepurposes. ( B ) Initial Charge Of Filter Media. ( C ) Complete Underdrain System And Raw Water Distributor As Per ManufacturerS Design. ( D ) M.S.Heavyclassfabricated-Epoxycoated / Postgalvanized Facepipingcomprisingof Connections With Ci Butterfly Valvesof Requiredsize Forinlet, Outlet, Backwash Inlet, Backwash Drain And Rinse Drain. Air Release Line With Gm Ball Valve Of Required Size. ( E ) Pressuregauges ( 100Mmdiabourdontypepressuregauge ) / Samplingpointswithss Isolation Cocks At Inlet And Outlet. ( F ) All Internal Parts Of The Filtration Plant Shall Be Coated With Two Coats Of Food Grade Epoxy Paint After Thorough Sand Blasting. All External Surfaces Of The Plantincluding Piping Shall Be Coated With Two Coats Of Red Iron Oxide / Zinc Chromate Primer Followed By Two Coats Of High Gloss Enamel Paint . ( G ) The Filter Shall Be Complete With All Gaskets / Fasteners Of Standard Quality As Required. ( H ) Thefiltershallbedesignedtogiveratedoutputatgivenrawwaterqualityandflowrate Withoutanyoperationalproblem Andshouldnotgetanylossofperformanceaslongasthe Operating Pressure Remains Within The Given Range. Any Additional Provision Is Required To Make Theitem Complete, Thesameshouldbeincludedherein.Theworkhastobecarriedthrough Authorised Vendor, Dealer / Representative Of Approved Make. The Filter Water Willbe Suppliedto Treated Water Tank Through Activated Carbon Filter, Softener & Uv Water Sterliser.Capacity - 525 Lpm Filtration Rate -20, 000Lph / Sqm ( Min. ) Filter Dia Approx.1.05 M ( Min. ) Filter Hos Min. : 1800 Mm ( Min. ) Working Pressure :3.0 Kg / Sq Cm.Test Pressure : 4.5 Kg / Sq Cm No. Of Unit - 1 Set 92 Supply And Fixing Activated Carbon Filter In Ms Welded Construction Fabricated In Accordance With Is 2825 From Minimum 6 Mm Thick M.S. Plate On Shell And Minimum 8 Mm Thick M.S. Plate On Dished Ends As Per Applicable Is Standards. The Filter Shall Have : ( A ) One No Pressure Tight Manhole And At Least One No. Pressure Tight Side Hole For Maintenancepurposes. ( B ) Initial Charge Of Activated Carbon ( C ) Complete Underdrain System And Raw Water Distributor As Per ManufacturerS Design.D ) M.S.Heavyclassfabricated-Epoxycoated / Postgalvanized Facepipingcomprisingof Connections With Ci Butterfly Valvesof Requiredsize Forinlet, Outlet, Backwash Inlet, Backwash Drain And Rinse Drain. Air Release Line With Gm Ball Valve Of Required Size. ( E ) Pressuregauges ( 100Mmdiabourdontypepressuregauge ) / Samplingpointswithss Isolation Cocks At Inlet And Outlet. ( F ) All Internal Parts Of The Filtration Plant Shall Be Coated With Two Coats Of Food Grade Epoxy Paint After Thorough Sand Blasting. All External Surfaces Of The Plantincluding Pipingshall Becoated With Two Coats Of Red Iron Oxide / Zinc Chromate Primer Followed By Two Coats Of High Gloss Enamel Paint . ( G ) The Filter Shall Be Complete With All Gaskets / Fasteners Of Standard Quality As Required.H ) Thefiltershallbedesignedtogiveratedoutputatgivenrawwaterqualityandflowrate Withoutanyoperationalproblem Andshouldnotgetanylossofperformanceaslongasthe Operating Pressure Remains Within The Given Range. Any Additional Provision Is Required To Make Theitem Complete, Thesameshouldbeincludedherein.Theworkhastobecarriedthrough Authorisedvendor, Dealer / Representativeof Approvedmake. Thewater Shallbe Receivedfrom Pressure Sand Filter And Supplied To Softener & Through Uv Sterliser Before Being Sent To Treated Water Tank.Capacity - 525 Lpm, Filtration Rate -20, 000Lph / Sqm ( Min. ) , Filter Dia Approx.1.05 M ( Min. ) , Filter Hos Min. : 1800 Mm ( Min. ) , Test Pressure : 4.5 Kg / Sq Cm, No. Of Unit - 1 Set 93 S&F Uv Water Sterilisers ( Between Filter &Clear Water Tank ) High Performance On Line Uv Water Sterilizers Of Capacity 225Lph Designed On At Least 250 J / Sq. M. Uv Dosage, Comprising Of Glass Uv Chamber In Ss 316 Housing, Uv Lamp And Electrical Circuit, Wall Mounted Model / Linemounted Model, Capacity 515Lph, Minimum Lamp Rating:150 Watts - 1 No. 94 Material And Labour For M.S. Black Pipe Flange Endheavy Gradewith All Fittings Like Elbow, Tee Reducer, Flange Nut Bolt With Washer Including Cutting, Welding And Joining Etc As Per Site Requirement And Applying Two Coats Of Syntheticenamelpaintofapproved Colourover Acoat Ofred Oxideprimer Includingtaking Up / Downof Existing Unserviceable Pipe Of Any Description Complete Of Size 50Mmall As Specified And Directed. Note:- Fixing Of Pipe Line Will Be Carried Out On Wall Or Floor Or Trenchesand Cost Of The Same Will Be Deemed To Be Included In The Rate Quoted However For The Pipe Line Laid Under Ground By Digging Trench Will Be Paid Saperately Complete All As Specified And Directed. 95 All As Per Srlitem No. 94 Above, Here-In-Before But 80 Mm Complete All As Specified And Directed. 96 All As Per Srlitem No. 94 Above, Here-In-Before But 100 Mm Complete All As Specified And Directed. 97 Supply And Fix In Replacement Of Ci Butterfly Valve Of Following Size As Per Is 13095, Pn 16, Wafer Type Without Lugs, Suitable For Clamping Between Flanges As Per Ansi B 16.1 Ci-125, Including Flanges, Fittings, Gasket, Nuts, Bolts, Washersetc.Includingtakingup / Downofexistingunserviceablebutterflyvalveofanydescription Complete Of Size 50 Mm All As Specified And Directed. Make - Stolzel, Leader / Crawley / Audco / L&T / Zoloto 98 All As Per Srlitem No. 97 Above, Here-In-Before But 80 Mm Complete All As Specified And Directed. 99 All As Per Srlitem No. 97 Above, Here-In-Before But 100 Mm Complete All As Specified And Directed. 100 Supply And Fix In Replacement Of Glass Tube Type Air Rotameterincluding Taking Down Existing Unserviceable Air Rotameter Of Any Description Complete All As Specified And Directed. 101 M&L Forreplacement Of Unsv Mbbr Mediafrom The Tank And Supply Of Filling Fresh Media Of Mbbr Media In The Main Reactor Complete All As Specified And Directed Of Existing / Suitable Make With The Following Specificatios:-Effective Surface Area Of Media Approx - 400 Sqm / Cum ( B ) Mesdia Ht Approx - 15 / 10 Mm ( C ) Media Dia Approx-22 Mm ( D ) Weight Per Unit Surface Area Approx -22 Mm ( E ) Voidage - >093 Gm / Cucm ( G ) Media Fill Range - 25-55% Of Volume 102 M&L For Replacing The Damage / Worn Out Of Tube Settler Media With New One In The Tube Settler Tank Of Size 2.5 X 4.5 X 6.5 Complete All As Specified And Directed By Engr-In-Charge. 103 S&F Rotational Polyethylene Water Storage Cylinderical Vertical Line With Close Top Hoisted And Fixed In Position Capacity Of 10000 Ltr Including All Necessary Fittings And Connections All As Specified And Directed Including Suitable Size Of Foundation As Per Requuirment At Site And Inlet Outlet Connection Complete All As Specified And Directed. 104 Material And Labour For Brick Protection With Sub Class B Bricks Old Size, Laid Dry, Flat Over Cable, Perpendicular Across The Cable In Trenches Complete All As Specified And Directed. 105 Providing And Fixing Hydropneumaticfilter Press Of 18 Plates 600X 600 Mm Size, With Suitable Sludge Pump ( Screw Type ) Alongwith Piping, Fittings Valve Etc. Complete All As Specified And Directed.Filter Press - Electrical & Mechanical Works 106 Supply Insattaltion Testing And Comissioning Of Electro Magnatic Flow Meter For , Measuring Of Inlet And Out Flow Of Sewage Inlet And Treated Water. The Meter Will Install With Proper Flange Valve Tee Union With Bypass Arrangment Complete All As Specified And Directed. 107 Suppling And Fixing Of Mechanicalbarscreenchamberwithminimumfreeboard300mmand Minimumsize1.5Mx0.8Mx0.3Mswd Andadditionalmanualsuitablesize Ssbarscreen Is Installedat Suitableangleattheinletofraw Sewagesumpbeforepumpingandmechanical System To Collect And Lifts / Transport The Screening Material . The Unit Shall Be Designed For Peak Flow , Andoneno.Ssslottedadditionalmanualfinescreen2mm Thickaftermechanicalbar Screentobefixedinchamberitself.Inletchamberofsuitable Sizewithssmanualoperated Spindleriser Ss 304 Gate Shall Also Be Provided Before Bar Screen Complete All As Specified And Directed. 108 Supply, Installation, Testing And Commissioning Of Sludge Feed Pumps Screw Type Complete With All Fittings & Accessories. Suitable Motor Of Required Hp & Rpm Operated On 415 Volts ±10%, 3 Phase, 50 Hz A.C. Supply With Mounting M.S. Fabricated Common Base Plate, Including Sludge Handling Systemfoundation And Foundation Bolts. ( Pump 2 Nos.- 1W+1S ) Complete All As Specified And Directed.Flow Rate ( Each ) - 2 M3 / Hrhead - 30 To 35Mtr 109 Supply, Installation, Testing And Commissioning Of Belt Type Oil Skimmer, Moc Of Drum , Oil Tray And Accessories Ss-304, Structure Of Oil Skimmer In Msep Complete All As Specified And Directed By Engr-In-Chargebelt Size : 150Mm Free Board-500Mm, Skimming Capacity- 40Lphnote : Tenderers May Note That Amount Of Credit Rs 86, 064.00 Will Be Deducted From The Total Amount Arrived, At The Time Of Acceptance Of Contract.
Contract Date: Mar 27, 2023 Contract Value : 72.55 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Sep 15, 2020 Contract Value : 3.31 Crore
Boards / Undertakings / PSU No of Bidders 5
Contract Date: Aug 20, 2020 Contract Value : 9.72 Lakh
Boards / Undertakings / PSU No of Bidders 2
TenderDetail
Loading tenders