View Bid Results For Rcc Indicator Tenders

We found 1282 Bid Results related to rcc indicator tenders. You can find Contractor details who won rcc indicator tenders along with contract details in Bid awards announcements section.

Filters
Stage
950
168
164
Tender Publishing Platform
69
1213
State / UT
33
215
146
141
129
81
77
59
56
51
33
32
29
29
24
22
20
20
14
14
13
13
11
10
9
8
7
6
4
2
2
2
2
1
Contract Value
416
145
472
248
Publish Date
1
0
0
0
0
Sector
26
503
175
136
118
92
73
43
26
25
22
13
13
12
6
6
5
3
2
2
1
1
1
1
1
1
1
Ownership
6
585
508
129
52
5
3
Within keyword
Active filters:
Showing 1–26 of 1282 tenders matching your filters
1.
Public Administrative Department #11458204 Technical Bid
supply and installation of electrical material and repairing, rewinding of motor pumps required and supply of material for daily repair works of water supply pipe line and pumps on for daily repair works of water supply on yearly basis , cable , 2.5 sq.mm submersible cable three core (copper) isi mark , 4 sq.mm submersible cable three core (copper) isi mark , 6 sq.mm submersible cable three core (copper) isi mark , 10 sq.mm submersible cable three core (copper) isi mark , 16 sq.mm submersible cable three core (copper) isi mark , 25 sq.mm submersible cable three core (copper) isi mark , 35 sq.mm submersible cable three core (copper) isi mark , cable with aluminum armored 3 core 50sqmm , cable with aluminum armored 3 core 70sqmm , fuse cut out , 16 ampere , 32 ampere , 63 ampere , 100 ampere , 150 ampere , 200 ampere , 300 ampere , fuse wire , 16 ampere , 32 ampere , 63 ampere , 100 ampere , m.c.c.b l &t make , 16 ampere , 32 ampere , 63 ampere , 100 ampere , 150 ampere , 200 ampere , 250 ampere , 300 ampere , 500 ampere , h.r.c.fuse , 16 ampere , 32 ampere , 63 ampere , 100 ampere , 150 ampere , 200 ampere , 250 ampere , 300 ampere , 500 ampere , main switch 3 pole , 16 ampere , 32 ampere , 63 ampere , 100 ampere , 150 ampere , 200 ampere , 250 ampere , providing and erecting transformer new ab switch complete set. , l.t. l.k. mk -1 dol starter 3 h.p./5 h.p. , no volt coil , contact patti set , relay , contact block , new starter set for 3 h.p./5 h.p. , 15/10 h.p. starter /star delta starter (l&t make mk-1) , no volt coil , contact patti set , relay , contact block , new starter set for 10 h.p./15 h.p. mk -1 , new starter set for 10 h.p./15 h.p. mu-g20 , contactor , mnx -225 , mnx -110 , mnx -a2 , mnx -a1 , mnx -25 , mnx -9 , ml -2 , ml -4 , oil starter 50 h.p. , contact fix patti , contact moving point , no volt coil , fibre plate , conection plate , starte minoir repairing , supplying & erecting new connection terminal beckelite connection plate with copper lugs & copper nut bolt for 50 hp , l&t co2-200 cos - 200a , l&t thermal overload relay mn 12 ct ratio 30 , single phase preventor minilec make , l&t capacitor 1/3 phase , l&t main switch dn-3 630 d , l&t mccb dn-2 250a , l&t mccb du-250 , relay 30a- 50a , relay 20a- 33a , fn 100 tpn switch disconnector fuse unit , l&t make fasd starter ml 1.5 suitable for 10/15 hp , 50 h.p.ats starter , timer , auxiliary switch , on off switch , no volt coil , monir repairing , 80 h.p. ats starter , timer , auxiliary switch , on off switch , monir repairing , 100 h.p. ats starter , timer , auxiliary switch , on off switch , monir repairing , aluminium lugs , 16 mm , 25 mm , 35 mm , 50 mm , 70 mm , 95 mm , 120 mm , 150 mm , 185 mm , 240 mm , 300 mm , copper lugs , 16 mm , 25 mm , 35 mm , 50 mm , 70 mm , copper bus bar , crimping tool manual , crimping tool hydraulic operated , transformer bush hv/lv 63/100/160/ kva , transformer rod hv/lv 63/100/160 kva , transformer oil filter , transformer new oil filling (filtered) , rewinding of motors , 1 hp el. motor (mono block) rewinding with material and labour , 3 hp el. motor (mono block) rewinding with material and labour , 5 hp el. motor (mono block) rewinding with material and labour , 10 hp el. motor (mono block) rewinding with material and labour , 15 hp el. motor (mono block) rewinding with material and labour , 1 hp el. motor (submersible) rewinding with material and labour , 2 hp el. motor (submersible) rewinding with material and labour , 3 hp el. motor (submersible) rewinding with material and labour , 5 hp el. motor (submersible) rewinding with material and labour , 7.5 hp el. motor (submersible) rewinding with material and labour , 10 hp el. motor (submersible) rewinding with material and labour , 15 hp el. motor (submersible) rewinding with material and labour , 20 hp el. motor (submersible) rewinding with material and labour , 30 hp el. motor (submersible) rewinding with material and labour , 35 hp el. motor (submersible) rewinding with material and labour , 80 hp el. motor (submersible pump ) rewinding with material and labour , 100 hp el. motor (submersible) rewinding with material and labour , 3 hp el. motor (submersible mono block) rewinding with material and labour , 5 hp el. motor (submersible mono block) rewinding with material and labour , 7.5 hp el. motor (submersible mono block) rewinding with material and labour , 10 hp el. motor (submersible mono block) rewinding with material and labour , 15 hp el. motor (submersible monoblock) rewinding with material and labour , 30 hp el. motor (submersible mono block) rewinding with material and labour , 50 hp el. motor (vt pump ) rewinding with material and labour , 2 hp mud pump set (vertical) rewinding with material and labour , 3 hp mud pump set (vertical) rewinding with material and labour , 5 hp mud pump set (vertical) rewinding with material and labour , 10 hp mud pump set (vertical) rewinding with material and labour , 15 hp mud pump set (vertical) rewinding with material and labour , minor repairing/ overhauling of pumps , 1 hp pump , 2 hp pump , 3 hp pump , 5 hp pump , 10 hp pump , 15 hp pump , 30 hp pump , 80 hp pump , repairs and maintenance 50hp vt pump for igatpuri city water supply scheme vertical turbine pump (water lubricated) incliding dowl assembly and discharge hed etc. on provided channel/rsj/rcc beam including erecting on providing sole plate with blue matching , a) removing , b) dismenting , bowl assembly loading, unloading, scrapping & cleaning, checking the bowl assembly… etv complete , making bowl shaft remetalising, machining, impeller fiting size machining… etc complete , making bowl bush bronze metal machining pressing thrugh & boaring… etc complete. , making impeller and impeller neck ring through cut& balancing work… etc complete. , making bowl body neck ring machining as per required impeller size… etc complete. , making impeller collet and lock machining and fitting… etc complete. , making new strainer with stainless steel jail… etc complee , supplying misc sundry & hardware material like new nut bolt gasket packing and gland packing… etc complete. , making threading work for line shaft of 5ft length and facing through polish… etc complete. , making line shaft new coupling as sleeve reconditioning and thrugh polish… etc complete. , making gland shaft stainless steel remetalising machining and through polish… etc comlete. , making old (gm) impeller nackring repairing on lathe machine work…etc complete. , bowl assembly, dismentaling & removing al parts and re-installing property labour charges. , making new line shaft 316 materal including of lathe machining work. , making rubber bush reconditioning…etc complete. , providing and erecting new rubber spider. , making 250mm column pipe-each 5 feet length scrapping & de rusting colouring and painting work…etc complete , transportation of dismantled parts of pump fom raw water pumping to nashik work shop including loading unloading…etc complete , transportation of dismantled parts of pump after repairing from nashik work shop to raw water pumping site with loading unloading …etc complete , assembling and re-erection of 50hp vt pump set at actual site. , supplying & erecting new coupling set with nut bolts and rubber. , supplying & erecting new line shaft s.s lenght – 5 feet. , supplying & erecting new line shaft coupler , supplying & erecting new line shaft sleeve , supplying & erecting new bowl shaft , repairs and maintenance 50hp vhs electric motor for , a) removing 50 hp vhs electric motor , b) dismantling 50 hp vhs electric motor , transportation of above motor form nashik work shop site to raw water pumping including loading & unloading with tools & tackles etc complete , rewinding and repairs of squirrel cage including motors 440 v,3 phase 50 cycles/sec, 1500 rpm with b class insulation including heating, oven baking varnishing, painting etc complete. (60 hp motor) , supplying taper roller bearing fag x-life 29326 , supplying ball bearing 6320 , supplying gland packing 20 mm , supplying champion packing 3m x 200m , a) assembling 50hp vhs electric motor , b) re- erection of 50hp vhs electric motor , transportation of dismantled parts of pump after repairing from nashik work shop to raw water pumping site with loading unloading …etc complete , supplying & erecting new connection terminal backlit connection plate with copper lugs & copper nut bolt for 60hp motor , supplying copper lugs 70sq.mm , 3 hp motorpump replacement of bearing (submersible/monoblock) , 5 hp motorpump replacement of bearing (submersible/monoblock) , 10 hp motorpump replacement of bearing (submersible/monoblock) , 15 hp motorpump replacement of bearing (submersible/monoblock) , 30 hp motorpump replacement of bearing (submersible/monoblock) , 80 hp motorpump replacement of bearing (submersible/monoblock) , 100 hp motorpump replacement of bearing (submersible/monoblock) , 50 hp motor pump replacement of bearing (turbine pump upper bearing ) bearing no. 7317 bep , 50 hp motor pump replacement of bearing (turbine pump lower bearing ) bearing no. 6212 , minor repairing of electric panels , 5 hp pump panel , 10 hp pump panel , 15 hp pump panel , 30/35 hp pump panel , 50 hp pump panel , 75/80/85 hp pump panel , repairing of 50 hp vfd panel (minor) , repairing of 50 hp vfd panel (major) , repairing of 80 hp vfd panel (minor) , repairing of 80 hp vfd panel (major) , rewinding of tranformer 63 kva , rewinding of tranformer100 kva , rewinding of tranformer 160 kva , supply & installation of new tranformer 63 kva , supply & installation of new tranformer 100 kva , supply & installation of new tranformer 160 kva , supply & installation of new 0.5 hp motor monoblock ( crompton/kirloskar/abb) , supply & installation of new 0.5 hp pistion pump set , supply & installation of new 3 hp motorpump set monoblock (crompton/kirloskar/texmo) , supply & installation of new 5 hp motor pump set monoblock (crompton/kirloskar/texmo) , supply & installation of new 5 hp motor open well sub mersible mono block (horizontal ) (crompton/kirloskar/texmo) , supply & installation of new 5 hp motor sub mersible (vertical) (ksb/kirloskar/lubi/ cri) , supply & installation of new 10 hp motor pump set monoblock (crompton/kirloskar/texmo) , supply & installation of new 10 hp motor open well sub mersible mono block (horizontal ) (crompton/kirloskar/texmo) , supply & installation of new 10 hp motor sub mersible (vertical) (ksb/kirloskar/lubi/ cri) , supply & installation of new 15 hp motor pump set monoblock (crompton/kirloskar/texmo) , supply & installation of new 15 hp motor open well sub mersible mono block (horizontal ) (crompton/kirloskar/texmo) , supply & installation of new 15hp motor sub mersible (vertical) (ksb/kirloskar/lubi/ cri) , supply & installation of new 30/35 hp motor open well sub mersible mono block (horizontal ) (crompton/kirloskar/texmo) , supply & installation of new 75/80 hp motor sub mersible (vertical) (ksb/kirloskar/lubi/ cri) , supply & installation of new 2 hp mud pump set (vertical) (ksb/kirloskar) , supply & installation of new 3 hp mud pump set (vertical) (ksb/kirloskar) , supply & installation of new 5 hp mud pump set (vertical) (ksb/kirloskar) , supply & installation of new 10 hp mud pump set (vertical) (ksb/kirloskar) , supply & installation of new 15 hp mud pump set (vertical) (ksb/kirloskar) , providing and erecting of flow meter repairing complete , repairing of flow meter transmitter card , replacements of flow meter electronic sensor , replacement of sensor cable , repairing of constant voltage transformer , repairing of flow meter display card , replacement of smps of flow meter , supplying & erecting 300mm size flow meter , supplying & erecting 200mm size flow meter , providing and supplying in standard lengths isi mark rigid unplasticised pvc pipes suitable for potable water with solvent cement joints including cost of couplers, as per is specification no. 4985 / 1988 excluding gst levied by gol and gom in all respect,including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).(as per mjp dsr 2018-19) , working pressure 4 kg./sq.cm , 63 mm , 75 mm , 90 mm , 110 mm , 140 mm , 160 mm , working pressure6 kg./sq.cm , 63 mm , 75 mm , 90 mm , 110 mm , 140 mm , 160 mm , providing and supplying in standard lengths isi mark rigid upvc pipes , 15 mm , 20 mm , 25 mm , 63 mm , providing isi mark gi. pipe of following class and dia. including all statutory duties & taxes such as gst levied by goi & gom in all respect, inspection charges, transportation to stores, etc. complete as per is-1239/2004. , medium , 15 mm , 20 mm , 25 mm , 32 mm , 40 mm , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , supply of necessary items related to hard wares required for daily repair works of water supply pipe line on yearly basis , upvc elbows 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 3 inch , upvc mta 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , upvc fta 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , pvc reducer , size 1/2 x 3/4 inch , size 3/4 x 1 inch , size 1 x 1 1/2 inch , size1 1/2 x 2 inch , size 2 x 2 1/2 inch , size 2 x 3 inch , size 2 1/2 x 3 inch , size 3 x 4 inch , size 4 x 5 inch , size 4 x 6 inch , size 5 x 6 inch , upvc reducer , size 1/2 x 3/4 inch , size 3/4 x 1 inch , size 1 x 1 1/2 inch , size1 1/2 x 2 inch , size 2 x 2 1/2 inch , size 2 x 3 inch , size 2 1/2 x 3 inch , pvc end cap plains 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , size 4 inch , size 6 inch , upvc end cap plains 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , pvc end cap threaded 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , upvc end cap threaded 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , g. i. end cap threaded (inside threaded ) , size 1/2 inch , size 3/4 inch , size 1 inch , g. i. end cap threaded (outside threaded ) , size 1/2 inch , size 3/4 inch , size 1 inch , pvc socket 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , size 4 inch , size 6 inch , size 8 inch , upvc socket 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , pvc bend 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , size 4 inch , size 6 inch , size 8 inch , upvc bend 6kg/cm2 , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , upvc ball valve , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , pvc ball valve , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , size 4 inch , g. i. bend , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , size 4 inch , g. i. socket , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , size 4 inch , size 6 inch , g. i. elbow , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , size 4 inch , size 6 inch , g. i. tee , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , size 2.5 inch , size 3 inch , size 4 inch , g. i. barrel nepple , 1/2 x 3 , 1/2x 4 , 1/2x 6 , 1/2 x 9 , 1/2x 12 , 3/4x 3 , 3/4x 4 , 3/4x 6 , 3/4x 9 , 3/4x 12 , 1x 3 , 2x 3 , 3 x 5 , pvc repairing coupler elastomatric , 63 mm. , 75 mm. , 90 mm. , 110mm , 160 mm. , pvc solution , 20 ml , 50 ml , 100 ml , 200 ml , upvc solution , 20 ml , 50 ml , 100 ml , 200 ml , 500 ml , m-seal , 10 gm , 50 gm , 100 gm , 200 gm , 500 gm , taparia spanners open ended , 10-11. , 12-13. , 14-15. , 16-17. , 18-19. , 20-21. , 22-23. , 24-25. , 26-27 , 28-29 , 30-31 , 32-33 , 34-35 , ring spanner , 10-11. , 12-13. , 14-15. , 16-17. , 18-19. , 20-21. , 22-23. , 24-25. , 26-27 , 28-29 , 30-31 , 32-33 , 34-35 , valve cap , 2 valve cap , 3 valve cap , 4 valve cap , 6 valve cap , 8 valve cap , 10 valve cap , 12 valve cap , 14 valve cap , air valve ball , 2 valve ball , 3valve ball , 4 valve ball , 5 valve ball , 6 valve ball , abrasive grinder wheel fo size 6 , abrasive grinder wheel fo size 8 , abrasive grinder wheel fo size 10 , 18(450 mm) size venus/ taparia pipe wrench , 14(350 mm) size venus/ taparia pipe wrench , 12(300 mm) size venus/ taparia pipe wrench , 9(2253 mm) size venus/ taparia pipe wrench , tikav arm (tikav danda) , tata tikav , favada arm ( favada danda) , tata favada , nut bolts as per requirement , nylon rope , industrial rubber sheet , hack -saw frame , gland , hack -saw blade , providing and fixing in position m.s. air valve boxes fabricated with 2mm thick m.s. plate, 30 x 30 x 3 mm size m.s. angle frame, concreting in m-150 for fixing the box in position, appling two coats of oil paint, painting chainage, locking arrangement, etc. complete as directed by engineer-in-charge. , for single ball air valve , for double ball air valve , providing and fixing c.i. road box including loading,unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete. , 100mm x 225mm(20kg) , 225mm x 300mm(40kg) , providing , hoisting and fixing in position c.i. manhole, frame and cover of best qualify and of required size and shape with locking arrangements including applying 2 coats of anticorrosive paint, etc. complete, etc. complete. , 90 x 60 cm size and weight 35 kg , rate on weight basis for any size and type of frame and cover , providing and fixing in position m.s. ladder 0.50 m wide consisting of 75 x 10 mm m.s. flats as stringers and 16mm dia m.s. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved, welding, anchoring and applying 3 coat of anti-corrosive paint, etc. complete as directed by engineer-in-charge. , providing and fixing water level indicator upto 5 m height including m.s. enamelled gauge plate 300mm wide 3mm thick, p.v.c. float, providing and fixing required accessories such as pointer, pulleys, nylon thread including cost of all material, labour, etc. complete. , providing and fixing water level indicator upto 5 m height including m.s. enamelled gauge plate 150mm wide 3mm thick, p.v.c. float, providing and fixing required accessories such as pointer, pulleys, nylon thread including cost of all material, labour, etc. complete. , rachet drill set isi mark , 12 mm (1/2) , 20 mm (3/4) , 25 mm (1) , pipe die set , 12 mm (1/2) , 20 mm (3/4) , 25 mm (1) , g.i. union , 12 mm (1/2) , 20 mm (3/4) , 25 mm (1) , patti valve m s , 12 mm (1/2) , 20 mm (3/4) , 25 mm (1) , 50 mm (2) , grease castrol , cotton rope , screw driver taparia , tester taparia , insulated electric plier 12taparia , hammer 1/2 kg , hammer 1 kg , hammer 1.5 kg , hammer 2kg , pahar 4 foot , pahar 6 foot , lock godrej 7 levers small size , lock godrej 7 levers big size , providing double flange sluice valve confirming for ls-14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspectioncharges, transportation upto departmental store, unloading, stacking excluding gst levied by goi & gom in all respect etc. complete. , sluice valves - pn -1 without bypass , 50 mm. , 80 mm , 100 mm. , 150 mm. , 200mm , 250 mm. , 300mm , 400mm , sluice valves - pn -1.6 without bypass , 50 mm. , 80 mm , 100 mm. , 150 mm. , 200mm , 250 mm. , 300mm , 400mm , providing and supplying isi mark cl dif reflux valves (non return valves ) of following dia including raihvay freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding gst levied, by goi & gom in all respect etc. complete. reflux valves as per i.s.5312 part i (1984) , reflux valves ( non return valve) - pn -1 without bypass , 50 mm. , 80 mm , 100 mm. , 150 mm. , 200mm , 250 mm. , 300mm , 400mm , reflux valves ( non return valve) - pn -1.6 without bypass , 50 mm. , 80 mm , 100 mm. , 150 mm. , 200mm , 250 mm. , 300mm , 400mm , check nut ( phosphor bronze / gun metal) of sluice valve with machining as per spindle , 50 mm. , 80 mm , 100 mm. , 150 mm. , 200mm , 250 mm. , 300mm , steel wire rope , plastic bucket 10 lit. , plastic bucket 20 lit. , plastic bucket 25 lit. , ghamela/round create 10 , providing q.nd supplying lsl standard d. l. specials & fitting with sealing rubber gasket of s.b.r,complete with cast iron follower gland and m. s. nut bolts coated or otherwise protected from rusting and suitable for d.l.pipes including cost of labour, materials, and transpotlaiion to stores, loading and unhading excluding gst levied by goi & gom in all respect etc. complete as per is-9523 , for all types of specials , bends,tees etc. , 80 to 300 mm dia , providing and supplying isi standard ms specials of required thickness with 3 coats of approved nlake epoxy paint (shalimar, ciba or matiindra & mahindra make) from inside and outside excluding gst levied by goi & gom in all respect including irrspection charges, transportation to stores and stacking, etc. complete. , for all types of ms specials , bends,tees flanges etc. , providing and supplying i.s.l. mark rubber gasket suitable for c.l. or d. l. pipe nf all class for tyton joints including inspection charges, transportation upto departrnental stores excludine gst levied by goi & gom in all respect etc. complete. , s.b.r. gaskets for c. l. / dl pipes. , 80 mm. , 100 mm. , 150mm , 200 mm. , 250 mm. , 300mm , s.b.r. tyton joint rubber ring for mechanical joints , 80 mm. , 100 mm. , 150mm , 200 mm. , 250 mm. , 300mm , providing and supplying in standard lengths polvethelene pioes. confirmino to.ls 4984/14151/12786/13488 latest version with necessary jointing material li ke mechanical connector i. e.thread / insert joint / quick release coupler joint/ compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding gst levied by gl & gom in all respect , pe 100 6 kg/ sq.cm , 25 mm. , 63 mm. , 75 mm. , 110 mm. , concrete breaker machine hitachi make , 6 kg. , 10.5 kg. , 12.5 kg. , 16 kg. , flexible plastic ring pipe ( bangadi pipe) , 25 mm , 50 mm , 75 mm , 110 mm. , plastic drum 200 lit. , flexible rubber pipe 1/2 , flexible rubber pipe 3/4 , flexible rubber pipe 3/4 , ci / ms water tap 1/2 , ci / ms water tap 3/4 , drill tap set 1/2 , drill tap set 3/4 , sintex three layer water tank 500 lit.to 5000 lit. capacity , pvc tail piece 6 kg , 63 mm , 90 mm. , 110mm , lsupply of c. l. mechanical compression flanged / socket tailpiece (popularly known as tm flanged / socket tailpiece) suitable for making flanged connection with the plain barrel of c. l. spun pipes ( as per - ls - 1536 120o1) and d. l pipes ( as per ls: 8329 / 2000).the tailpiec to be supplied complete with sealing rubber gasket of s.b.r, c.l. follower glands and m.s. nut bolts.the whole assembly should be mechanically and hydraulically tested to the provisions as laid down in ls:1538 /1993. the rates are inclusive of cost of material, freight charges, loading,transportation and unloading at departemental store, excluding gst levied by gol and gom in all respect, etc.complete. , 80 mm , 100 mm. , 150 mm. , 200mm , 250 mm. , 300mm , supply of c.i. mechanical compression collar coupling suitable for c.l. spun pipes (as per ls-1536/2001) and complete with sealing rubber gasket of sbr, c.1., follower glands and m.s. nut bolts. the whole assembly should be mechanically and hydraulically tested to the provisions as laid down in ls:1538/1993) including all statutary duties and taxes such as gst levied by gol and gom in all respect . , 80 mm , 100 mm. , 150 mm. , 200mm , 250 mm. , 300mm , supply of c.i. mechanical compression collar end cap suitable for c.l. spun pipes (as per ls-1536/2001) and complete with sealing rubber gasket of sbr, c.1., follower glands and m.s. nut bolts. the whole assembly should be mechanically and hydraulically tested to the provisions as laid down in ls:1538/1993) including all statutary duties and taxes such as gst levied by gol and gom in all respect . , 80 mm , 100 mm. , 150 mm. , 200mm , 250 mm. , 300mm , di pipe cutter machine heavy duty 600w ac 220- 240 v (make - bosch, hitachi) , ferrule 15mm , ferrule 20mm , ferrule 25mm , brass elbows 15mm , brass elbows 20mm , brass elbows 25mm , gi coupling , size 1/2 inch , size 3/4 inch , size 1 inch , size 1.5 inch , size 2 inch , taplon tape , supply of hdep pipe , 100mm , 150mm , supply of hdep tail pice , 100mm , 150mm , supply of ms flange , 100mm , 150mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Maharashtra View Result →
2.
Science and Technology #11347627 AOC
Bids Are Invited For Cleanroom Modular Wall Panels 100 Mm Thick Wall Panel , Cleanroom Modular Wall Panels 50 Mm Thick Wall Panel- For Civil Column Coverings Also , Cr Wall Panel Cpvc 25Mm Dia 2Mm Conduit For Electrical Switches 80-50Mm , Cleanroom Modular Ceiling Panels 50Mm Thick Ceiling Panel Area , Double Glazed Vision Panels 1000Mm X 1000Mm Double Glazed Vision Panel , Coving R70 - Aluminium Extruded Coving -Male - Female- Powder Coated With Accessories , Coving R90 - Aluminium Extruded Internal Coving Powder Coated With Accessories , Coving 2D-50Mm 3D-80 Mm- For R 70 - R 90 Coving To Concealed On The Corners , Coving -Cut-Outs In The Wall Panels And Ceiling Panels , R2 Return Air Raiser Size 600Mmx80mm Grill Size 650Mmx500mm , R2 Return Air Raiser Size 700Mmx200mm- Grill Size 750Mmx500mm , Cleanroom Scientific Doors- 1000Mmx 2100Mm Single Leaf Scientific Door , Cleanroom Scientific Doors -1200Mmx 2100Mm Single Leaf Scientific Door , Cleanroom Scientific Doors -1800Mmx 2100Mm Double Leaf Emergency Scientific Door , Cleanroom Scientific Doors- 1000Mmx2100mm Single Leaf Emergency Door , Cleanroom Scientific Doors- Double Side Operated Lock And Key With Ml 100D , Cleanroom Scientific Doors- Dc 60 Sm Door Closure , Cleanroom Scientific Doors - Ss 304 Ball Bearing Butt Hinges , Cr Scientific Doors - Double Glazed View Panels 350X750 With Tape And Sealants , Cleanroom Scientific Doors- Ss 304 Single Side D Handles 254 X 19 Mm Dia , Cleanroom Scientific Doors- Door Bottom Seals , Cleanroom Scientific Doors- Ss304 Push Plates , Cleanroom Scientific Doors- Ss304 Kick Plates , Cleanroom Scientific Doors- Tower Bolt , Cleanroom Scientific Doors- Double Point Panic Bar , Vinyl Flooring -Esd Flooring , Dynamic Pass Box Nflp- Working Area- 600W X 600D X 600Hmm 2 Way , Air Shower Nflp- Working Area- W 800Mm X D 900Mm X H 2000 Mm 2 Way , Dynamic Garment Cabinet- Internal Dimension- 1200 Mm W X 450 Mm D X 1800 Mm H , Dynamic Garment Cabinet-Air Curtains , Ss Furniture-Ss Cross Over Bench 2 Meter Length 2000X500x350 , Ss Furniture- Ss Chairs , Ss Furniture- Ss Tables , Ahu-01 Recirculation Type 19500 Cfm Static-180 Dehumidifier-13934 Cfm 44Tr 87Kw , Ahu Pre-Cooling Unit 19500 Cfm Capacity Fresh Air- 900 Cfm Cooling- 11Tr , Ahu-02 Recirculation Type 700 Cfm Ahu Static- 150 Cooling Tr- 6 , Air Distribution- 24-Gauge Sheet Ducting Upto 750 Mm Duct Width , Air Distribution- 22-Gauge Sheet Ducting 750 Mm To 1200 Mm Duct Width , Air Distribution- 20-Gauge Sheet Ducting 750 Mm To 1200 Mm Duct Width , Air Distribution - Ms Angle Frame For Ducting With Red Oxide And Epoxy Paint , Duct Insulation System-Supply Duct With 19 Mm Thick Insulation , Duct Insulation System-Return Duct With 13 Mm Thick Insulation , Duct Insulation System-Aluminium Foil Tapes For Covering The Joints Each Roll 50 Rmt , Fire Damper 18G Gi Sheet Al Blades 150Mm Chrome Spindles 120Min Ul-555 Rated , Fire Damper- Fusible Link And Spring Mechanism , Fire Damper- Limit Switch , Volume Control Damper , Hooded Type Hepa Filters- 450Mm X 450Mm X 152Mm Hepa Filter , Hooded Type Hepa Filters- 610Mm X 1210Mm X 152Mm Hepa Filter , Supply Air Diffusers- 300Mm X 300Mm Neck Size 4-Way Square Diffusers , Duct Mounted Heaters - Thyristor Type Non-Flame Proof- 35 Kw Duct Mounted Heater , Condensing Units- 11 Tr Condensing Units , Condensing Units- 11 Tr Condensing Unit For Pre Cooling Unit , Condensing Units- 3 Tr Condensing Units , Condensing Units- Copper Piping With Accessories At Actual Measurements , Magnehelic Gauge Dial Type With Ss Box Pressure Range 0 To 10Mm , Temperature And Rh Indicators , Validation And Documentation , Mv-Lv-Pcc-Mcc Panels-Main Mvp Panel-01 , Mv-Lv-Pcc-Mcc Panels- Ups O-P Sync Panel-Db-01 , Mv-Lv-Pcc-Mcc Panels- Ahu Control Panel-01 , Mv-Lv-Pcc-Mcc Panels-Ahu Control Panel-02 , Lt Db 3Ph 6-Way Vtpn-Etpn-Fabricated 63A Tpn 10Ka Mcb Incomer - Rpdb-01 , Lt Db 3Ph 6-Way Vtpn-Etpn-Fabricated 40A Fp Mcb Incomer - Rldb-01 , Lt Db 3Ph 6-Way Vtpn-Etpn-Fabricated 63A Tpn 25Ka Mccb Incomer - Epdb-01 , Lt Db 3Ph 6-Way Vtpn-Etpn-Fabricated 40A Fp Mcb Incomer - Eldb-01 , Lt Db 3Ph 12-Way Vtpn-Etpn-Fabricated 125A Tpn 36Ka Mccb Incomer - Etpdb-01 , Ups 160Kva 3Ph In-3Ph Out With 30 Min Backup Battery Bank And Rack - Ups-01 , Cleanroom Light Fixtures- 20W Lights In New Room , Cleanroom Light Fixtures- 20W Lights In Room D , Cleanroom Light Fixtures - 40W Led Bottom Openable 600Mmx600mm For Rooms And Walk Area , Switch Socket 3Ph 63A 5Pin Industrial With Mcb And Plug Top - Ss Cover Plate , Switch Socket 3Ph 32A 5Pin Industrial With Mcb And Plug Top - Ss Cover Plate , Switch Socket 1Ph 25A 3Pin Industrial With Dp Mcb And Plug Top - Ss Cover Plate , Switch Socket 1Ph 6Module 6-16A With Polycarbonate Plate - Rps Power , Switch Socket 1Ph 6Module 6-16A With Polycarbonate Plate - Ups Power , Switch Socket 1Ph 3Module 6-16A With Polycarbonate Plate - Rps Power , Switch Socket 1Ph 2Module 6A One-Way With Polycarbonate Plate - Raw Power Light , Switch Socket 1Ph 2Module 6A One-Way With Polycarbonate Plate - Ups Power Light , Switch Sockets- Single Phase 6Module Surface Mounting Pvc Boxes With 6-16A Switch Sockets , Switch Sockets- Single Phase 3Module Surface Mounting Pvc Boxes With 6-16A Switch Sockets , Lt Cable- 3.5Cx300 Sqmm A2xfy Al. Armoured Xlpe Cable 2 Runs , Lt Cable- 3.5Cx240 Sqmm A2xfy Al. Armoured Xlpe Cable , Lt Cable- 1Cx150 Sqmm Yy Cu. Flexible Cable , Lt Cable- 4Cx35 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Lt Cable- 4Cx25 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Lt Cable- 4Cx10 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Lt Cable- 4Cx6 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Lt Cable- 4Cx4 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Lt Cable- 4Cx1.5 Sqmm. 2Xwy Cu. Armoured Xlpe Cable , Lt Cable- 5Cx4 Sqmm. Cu. Flexible Cable , Lt Cable- 3Cx4 Sqmm. Cu. Flexible Cable , Lt Cable- 3Cx2.5 Sqmm. Yy Cu. Flexible Cable , Lt Cable- 3Cx1.5 Sqmm. Yy Cu. Flexible Cable , Lt Cable- 1Cx6 Sq.Mm Yy Cu. Flexible Green Wire , Lt Cable- 1Cx4 Sq.Mm Yy Cu. Flexible Green Wire , Lt Cable- 1Cx2.5 Sq.Mm Yy Cu. Flexible Green Wire , Cable Terminations- Termination Of 3.5Cx300 Sqmm A2xfy Al. Armoured Xlpe Cable , Cable Terminations- Termination Of 3.5Cx240 Sqmm A2xfy Al. Armoured Xlpe Cable , Cable Terminations- Termination Of 1Cx150 Sqmm Yy Cu. Flexible Cable , Cable Terminations- Termination Of 4Cx35 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Cable Terminations- Termination Of 4Cx25 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Cable Terminations- Termination Of 4Cx10 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Cable Terminations- Termination Of 4Cx6 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Cable Terminations- Termination Of 4Cx4 Sqmm 2Xwy Cu. Armoured Xlpe Cable , Cable Terminations- Termination Of 5Cx4 Sqmm. Yy Cu. Flexible Cable , Cable Terminations- Termination Of 3Cx4 Sqmm. Yy Cu. Flexible Cable , Cable Terminations- Termination Of 4Cx1.5 Sqmm. 2Xwy Cu. Armoured Xlpe Cable , Cable Terminations- Termination Of 3Cx2.5 Sqmm. Yy Cu. Flexible Cable , Cable Terminations- Termination Of 3Cx1.5 Sqmm. Yy Cu. Flexible Cable , Cable Terminations- Termination Of 1Cx6 Sq.Mm Yy Cu. Flexible Green Wire , Cable Terminations- Termination Of 1Cx4 Sq.Mm Yy Cu. Flexible Green Wire , Cable Terminations- Termination Of 1Cx2.5 Sq.Mm Yy Cu. Flexible Green Wire , Cable Trays And Its Earth Strips- 400X50x2mm Hot Dip Galvanized Ladder Type Cable Tray , Cable Trays And Its Earth Strips- 300X50x2mm Hot Dip Galvanized Perforated Type Cable Tray , Cable Trays And Its Earth Strips- 100X50x2mm Hot Dip Galvanized Perforated Type Cable Tray , Cable Trays And Its Earth Strips- 50X35x2mm Hot Dip Galvanized Perforated Type Cable Tray , Cable Trays And Its Earth Strips- 300X10x1.2Mm Gi Cable Tray Cover , Cable Trays And Its Earth Strips- 100X10x1.2Mm Gi Cable Tray Cover , Cable Trays And Its Earth Strips- 50X10x1.2Mm Gi Cable Tray Cover , Cable Trays And Its Earth Strips- 400X50x2mm Hot Dip Galvanized Ladder Type Cable Tray Bends , Cable Trays And Its Earth Strips- 300X50x2mm Hot Dip Galvanized Perforated Type Cable Tray Bends , Cable Trays And Its Earth Strips- 100X50x2mm Hot Dip Galvanized Perforated Type Cable Tray Bends , Cable Trays And Its Earth Strips- 50X35x2mm Hot Dip Galvanized Perforated Type Cable Tray Bends , Supply And Installation Of Earthing- 50X6mm Gi Earth Strip - Hot Dip , Supply And Installation Of Earthing- 25X3mm Gi Earth Strip - Hot Dip , Earthing - Copper Bonded Rod 254 Microns Ul Listed With Rcc Pit Chamber 450Mmx450mm , Pvc Frls Conduit Heavy Duty 25Mm Dia 1.5Mm Thick Rigid Grey With Accessories , Pvc Frls Conduit Heavy Duty 19Mm Dia Flexible Black With Bends And Accessories , Safety Electrical Items- 2000X1000x6mm Thick Corrugated Rubber Mats , Safety Electrical Items- Start-Stop Remote Pushbutton Stations - Ip66 , Civil Works - Demolishing And Construction , Statutory And Miscellaneous Total Quantity : 20237
Contract Date: Ref. Documents Contract Value : 2.91 Crore
Government Departments No of Bidders 10
3.
Housing Urban and Rular Development #11300693 AOC
Tender for Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : B)All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A All Kinds Of Soil , Earthwork In Surface Excavation Not Exceeding 30 Cm Depth(But Exceeding 1.5 M Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Beyond Work Site For All Leads Lift Disposed Earth To Be Leveled And Neatly Dressed In: B Hard Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Providing & Laying Of Minimun 80Mm Thick Factory Made Shot Blasted Cement Concrete Interlocking Paver Blocks Of Minimum M40 And Above Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design/ Shape Laid In 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand Etc. All Completed As Per The Direction Of Engineer-Incharge. The Product Should Comply With Is 15658: 2006 And Manufactured By Iso 9001: 2008 Certified Plant.1)Size: 210Mm X 150Mm X 80Mm Thick (Type: Rectangular Type Pavers) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.A)Size 30 Cm L X 50 Cm H X 15 Cm T , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing Of Seater Made Of Cast Iron And Powder Coated Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. , Providing And Fixing Of A Artificial Cricket Pitch , Monia Tiles , Supplying And Installation, Fixing Nylon Net All Around Verticle Net Garware Make Or Its Equivalent 50Mmx50mmx2.50Mm Thick As Approved By The Engineer-In-Charge.Top Net 50X50mm X1.75Mm Thick.Wirerope Complete Fixing Of Wire Ropes Of 5Mm With Turnbuckleand Dog Clips. Etc. Complete .( Contractor Has To Bear All The Cost And Arrange All Permissions For Interstate Transit Of Goods Including Storage Of The Goods). , Triangle Brush And Handy Turf Brush Set , Sbr Enfield , Supplying And Erecting Integrated Led Round Burial Light 6W Ip65 & Ik10 Class Having Pressure Die-Cast Housing, Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 85 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 100-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 50,000 Hrs At L50b50 , Slat Spray Tested For 500 Hrs. Including Making Of Recess Of Appropriate Size For Flushing Into Surface With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver With U Shaped Bracket With Minimum 2 Years Warranty As Per Specification No. Fg Odf/Fl. , Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With Minimum 2 Years Warranty As Per Specification No. Fg-Idf/Led. , Supply And Erecting Of 9 Inch (225 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories(A) Cat A. , Supplying And Erecting Concealed Type Foot/Step Light Max. 5W Having Ip67, Ik10 Rated Pressure Die Cast Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs At L70b50, Including Driver By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface With Minimum 2 Year Warranty. , Supplying And Erecting Integrated Led Post Top 45W Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 105 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30,000 Hrs At L50b50 , Including Driver Complete With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supply And Erecting Of 3 Mtr High Decorative Pole With Base Plate And Pole Cap , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 50 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Masonry Open Duct, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.. 4 Core 4 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 Core 50 Sq.Mm , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying&Erectingwatertightterminalboxof1.6Mm(16Gauge)Crcasheet Of Size 200 X 150 X 150 Mm. Complete On Pole As Per Specification No. Cb-Sb , Supply And Providing Chemical Earthing System (Pipe In Pipe Type) With Outer Pipe Of The Electrode Having Minimum 50Mm Diameter As Per The Enclosed Specifiations And Drawing.The Outer And The Inner Hot Dip Galvanised Ms Pipes Shall Conform To The Specifications And The Space Inbetween Shall Be Filled With Highly Crystalline Conductive And Anti- Corrosive Mixture Conforming To Is-3043. The Earth Electrode Shall Be Cpri Tested. The Scope Of Work Includes Boring( 300Mm Dia Mimnimum)/Exvavation Of Soil/Hard Rock, Refilling With Required Quantity Of Back Fill Compound/Ground Resistance Enhancement Powder Of Requisite Quantity, Compaction, Constuction Of Masonary Chamber Etc Complete As Required To Obtain The Desired Value. Aluminium Tag With Embossed Earthing Value Shall Be Permanently Attached To The Pipe Electrode(B) 2 Metres Length Electrode , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 8 Swg Copper Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supply Of Back Fill Compound/ Groung Resistance Enhancement Powder Conforming To The Enclosed Specifications. , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Light Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following :Auto Manual Swithc 1 Nos Street Light Control 32A 4Pole Contractor 4 Nos. Manual Control Switch With 4 No. / Nc Aux. Contacts One Electronic Timer With 10A Output Contactors For Operating Four Contactors Timer Unit Shall Be In A Separate Compartment With Glass Seal Provision If Any. And Possible To Adjust The Time Settings .3 Phase Meter And Mcb Arrangment With Modem And As Per Ged Requirement . Along With Necessary Stand And Earthting Brought Forward For Necesaary Connection On Both Side Of Panel Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor, Selector Switch Shall Be Protected By 2 Amps Tp Mcbs. 1 .Sets1breaker On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Dg Incomer63 Amps 4Pole,36 Ka Mccb, Ats 63 A With 415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Outgoing 32 A 4 Pole Mcb ,36Ka Set1 Spare Feeder63 Amps 4 Pole Mcb ,36 Kaset 1 ,25 Amps 4 Pole Mcb , 36 Ka Set1 , , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Feeder Pillar Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following : Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor,On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 20 Outgoing 32 A Four Pole Mcb ,36Ka Set 35 63 Amps 4 Pole Mcb ,36 Kaset 10 ,25 Amps 4 Pole Mcb , 36 Ka Set 10 , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 58.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50 Hz, 0.8 P.F., A.C. Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2/G3 And Maximum Fuel Consumption 9.98 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads, With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc., On Provided M20 Grade cement concrete Foundation As Per Specification No. Gen-Dg
Contract Date: Jun 17, 2026 Contract Value : 1.20 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
4.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
5.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
6.
Drinking Water Supply and Sanitation #11257813 AOC
Tender For pipe water supply To Paraja Limka Village:- Paraja Limka Gp Padampur Under Koraput Block Under Dmf(2023-24) Programme.- 1 CONSTRUCTION OF 50,000 LTR Capacity RCC OGR 2 Designing , construction, testing and commissioning of 50,000 ltr capacity circular shape flat bottom with domb shape RCC on the ground reservoir(OGR) including supplying , fitting, fixing of M.S and aluminuim ladder , water level indicator, lightening arrester 1 nos. 80 mm CI puddle collar-4, 2 nos. CI MH cover, Inlet & Outlet arrangement with 80 mm dia GI pipe - 18 mtr and soil testing & drawing design etc. testing of the joints all complete fitting and fixing 80 CI sluice valves-2 Nos, Sluice valve chamber -2 nos of standard make providing CC M-25 for RCC work with 20mm & down grade size hg chips with 20mm thick cement plater over the cement concrete work, cement punning over plaster surface and painting 2 coats of water proofing weather coat etc. all complete as per approved drawing and design as per direction of Engineer-in-Charge. 3 CONSTRUCTION OF PUMP HOUSE 4 Supplying all labour, T&P and materials for earth work excavation in foundation in all kinds of soil with all lead & lift including dressing the sides & levelling the bed of the foundation as directed by the Engineer-in-charges complete as per specification & direction of the Engineer-in-charge. 5 Supplying all labour, T&P and materials and providing Cement Concrete (1:4:8) in foundation and plinth with 4cm. H.G.Stone metal with cost, conveyance, royalty, taxes of all materials required for the work as per specification & direction of the Engineer-in-charge. 6 Supplying all labour, T&P and materials and providing R.R. H.G.Stone masonary with C.M.(1:6) in foundation and plinth with granite stone including cost, conveyance, labour, tax, royalty of materials to worksite complete as directed by the Engineer-in-charge. 7 Supplying, filling in foundation & plinth with sand in 15cms. (9) thick layers with the cost conveyance royalties, taxes of the materials complete as per specification and direction of the Engineer-in-charge 8 Supplying all materials, labour T&P providing R.C.C. (1:2:4) work using 12mm size hard black hand broken granite stone chips of approved quality and from approved quarry including hoisting lowering laying and compacting concrete watering and curing for four weeks, finishing the exposed surface smooth including cost conveyance taxes and royalty of all materials and labour with T&P required for the work etc, complete in all respect .as per specification and direction of the Engineer-in-charge.(Plinth Bend) 9 Supplying all materials, labour, T&P and providing Brick work with C.B Bricks in c.m (1:6) in superstructure using well burnt C.B bricks of size 23cm x 11cm x 8cm including cost, conveyance, royalty of all materials as per specification and direction of the Engineer-in-charge. 10 Supplying all materials, labour T&P providing R.C.C. (1:2:4) work using 12mm size hard black hand broken granite stone chips including cost conveyance taxes and royalty of all materials and labour with T&P required for the work etc, complete in all respect but excluding cost of MS Rods or Tor Steel and binding wires of 18 to 20 gauge as per including the cost of required quantity of centering and shuttering as per the dirction of the Engineer in Charge. 11 Lintel 12 Chajja 13 Straightening bend up or coiled rods cutting bending, cranking, hooking, welding or jointing (if required) the M.S. Rods or Tor Steel and binding wires and binding, tying the grills, hoisting, lowering and placing in proper position as required for R.C.C. works including cost, conveyance and taxes of M.S. Rods or Tor Steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc, complete in all floors as per specification and direction of the Engineer-in-charge. 14 Cost of M.S doors and windows : 15 Labour for fitting & fixing M.S. choukath to door & windows including making holes in the brick wall and fixing the clamps by using C.C (1:2:4) by using 12mm. size h.b.g chips with all cost, conveyance, labour, T&P etc., required for the work complete as per specification and direction of the Engineer-in-charge. 16 Supplying all materials, labour, T&P and providing 12mm (1/2) thick cement plaster (1:6) finished smooth with cost and conveyance of all materials as per specification and direction of the Engineer-in-charge. 17 Supplying all materials, labour, T&P and providing C.C. (1:2:4) work using 12mm size hard black broken granite stone chips including cost, conveyance, royalty & taxes etc, complete in all respect but excluding cost of M.S. Rods or Tor Steel and binding wires of 18 to 20 gauge as per specification and direction of the Engineer-in-charge. 18 Providing, fixing tiles in dados skirting and risers of steps on 12mm. thick cement plaster(1:3) jpinted with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing with cost, conveyance of all materials royalty, taxes etc, complete & as per the direction of the Engineer-in-charge. 19 Providing & fixing (Glazed) tiles in all floor & treads of steps & landing on 25 mm thick bed of cement mortar in proportion (1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing & polishing with cost, conveyance of all materials royalty, taxes etc, complete & as per the direction of the Engineer-in-charge. 20 Supplying all materials, labour, T&P and providing 20mm (3/4) thick cement plaster (1:6) finished smooth to out side of stone work after raking out the joint including, watering and curing with cost and conveyance of all materials and labour with T&P ,all taxes and royalties etc., complete in all respect in all floors as per specification and direction of the Engineer-in-charge. 21 Supplying all material, labour, T&P and providing grading concrete with C.C(1:2:2) using 06mm. Size hard stone broken chips of approved quality including hpisting and laying not exceeding 25mm. thick with proper packing and required slope, with cost conveyance and taxes of all materials and labour with T&P required for the work etc, complete in all respect as per specification and direction of the Engineer-in-charge. 22 Supplying all labour, T&P and materials and finishing walls with two coats of weather coat over a coat of white wash with good shell lime with cost, conveyance, royalties and taxes of all the materials and labour with T&P required for the work etc, complete in all respect in all floors as per specification and direction of the Engineer-in-charge. 23 Painting two coats with any approved paint to new wood work and iron work including sand papering, polishing the surface, with cost conveyance and taxes of all materials and labour with T&P required for the work etc, complete in all respect including the the cost of appoved paint as per specification and direction of the Engineer-in-charge. 24 LAYING OF RISING MAIN 25 Earth work in excavation of trenches for laying of pipe line including dressing, leveling the bed upto required depth & within initial lead of 50mtrs & 1.5mtrs initial lift breaking clods to maximum size (5 to 7cm) laying in layers not exceeding 0.30mtrs in depth etc. complete including cost of all labour, T&P, pipes, fittings and specials etc.required for completion of the item as per specification & direction of Engineer in charge. 26 In all kind of Soil : (500.00mtr x 0.38mtr x 0.90mtr) 27 Supplying all materials including HDPE pipes, fittings and specials, labour, T&P for laying in trenches unplasticised HDPE pipes of the following outside diameter for all classes and specials as required at site, including jointing with solvent cement by non heat application method excluding the cost of earth work in excavation but including the cost of pipes cost of fitting and specials & testing the pipe line etc. all complete as per direction of Engineer-in-charge. 28 90 mm HDPE Pipe PE-80 PN-6 29 Supplying all labour, T&P for filling excavated earth in the pipe line trenches by laying in layers not exceding 9 (225mm) including watering and ramming as per the direction Engineer-in-charge. 30 In all kinds of soil : 31 Supplying all labour T&P fitting and fixing of CI sluice valves with double flanged ends in the water line for controlling purposes conforming to IS:14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including testing as per specicication complete 32 80 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 33 Supplying all labour, material, T&P and constructing brick masonry valve chambers of following mentioned inetrnal dimension, complete with C.C (1:4:8) with 40 mm size hbg metal at the bottom, C.B brick masonry in c.m(1:4) with internal plastering and R.C.C top cover with C.C(1:2:4) with 12mm size hbg metal & MS Rod 0.85qntl per 1 cum and with 12mm thick cement plaster (1:4) complete in all respect as per the direction of the Engineer-in-charge. 34 SluiceValve/NR Valve Chamber (Size 0.90mtr x 0.90 mtr x 1.15 mtr) 35 LAYING OF DISTRIBUTION SYSTEM 36 Earth work in excavation of trenches for laying of pipe line including dressing, leveling the bed upto required depth & within initial lead of 50mtrs & 1.5mtrs initial lift breaking clods to maximum size (5 to 7cm) laying in layers not exceeding 0.30mtrs in depth etc. complete including cost of all labour, T&P, pipes, fittings and specials etc.required for completion of the item as per specification & direction of Engineer in charge. 37 In all kind of Soil : (800 mtr x 0.38mtr x 0.90mtr) 38 Supplying all materials including HDPE pipes, fittings and specials, labour, T&P for laying in trenches unplasticised HDPE pipes of the following outside diameter for all classes and specials as required at site, including jointing with solvent cement by non heat application method excluding the cost of earth work in excavation but including the cost of pipes cost of fitting and specials & testing the pipe line etc. all complete as per direction of Engineer-in-charge. 39 63 mm HDPE Pipe PE-80 PN-6 40 Supplying all labour, T&P for filling excavated earth in the pipe line trenches by laying in layers not exceding 9 (225mm) including watering and ramming as per the direction Engineer-in-charge. 41 In all kinds of soil : 42 Supplying all labour T&P fitting and fixing of CI sluice valves with double flanged ends in the water line for controlling purposes conforming to IS:14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including testing as per specicication complete 43 80 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 44 100 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 45 80mm CI NR Valve IS- 14846/2000 PN-1.00 46 15 mm dia CISingle Air Valve IS 14845/2000 47 Supplying all labour, material, T&P and constructing brick masonry valve chambers of following mentioned inetrnal dimension, complete with C.C (1:4:8) with 40 mm size hbg metal at the bottom, C.B brick masonry in c.m(1:4) with internal plastering and R.C.C top cover with C.C(1:2:4) with 12mm size hbg metal & MS Rod 0.85qntl per 1 cum and with 12mm thick cement plaster (1:4) complete in all respect as per the direction of the Engineer-in-charge. 48 SluiceValve/NR Valve Chamber (Size 0.90mtr x 0.90 mtr x 1.15 mtr) 49 Air Valve Chamber(Size 0.75mtr x 0.75mtr x 1.15mtr) 50 Supplying all materials, labout T&P pipes, fittings, push/rotary type water tap for construction of RCC single mouth stand post of size 250x250 mm platform of 1050x1050 mm with 3000 mm waste water drain as per approved drawing design and specification with CC M20 unsing 12 mm size h.g.c.b chips of approved quality from approved quarry including hoisting, laying and compacting and finishing the exposed surface smooth watering and curing including earth work in excavation in hard soil and rigid smooth centring and shuttering for cement concrete works along with MS Rainforcement as per specification including cost, royalty and conveyance charges of all materials etc. complete directed by Engineer in Charge. 51 Transporting and supplying all materials, labour T&P, fabricating, fitting and fixing with specials at the site using Electric resistance welded pipes of reputed make (TATA / Zindal ), confirming to IS 1239 (P-1) 2004, IS 1978 & IS 3598, medium quality & standard weight, including cutting the pipes & flanges, drilling the bolt holes in the flanges, matching the pipes and flanges and jointing with proper gradient & alignment, welding with arc welding using electrodes with power generated by using mobile diesel generator set, etc. complete as per direction of Engineer in charge, including painting two coats with black anti-corrosive paint over one coat of primer, all cost, conveyance, taxes of paints, cost of fittings as T, Bend, Offsets, Nuts and bolts, Leather packing etc. but including the cost of flanges and required earthwork, cutting holes in masonry works etc. 52 80 mm dia G.I pipe 53 INTERNAL ELECTRIFICATION 54 Supplying the following materials ,required labour and T &P and providing internal electrification to pump house as required at site including commisioning and testing as per the direction of the Engineer in Charge. 55 Surface wiring to light point in 20mm dia PVC cond. Pipe on MS board wiyh 3mm thick mulltistand copper wire. 56 a. Short point 57 b. Medium point 58 Surface wiring to 3pin 5A plug point in 20m dia pvc conduit on existing board . 59 surface wiring to 3pin 5A plug point in 20m dia pvc conduit on existing board . 60 Medium point 61 B.H. Fitting including all connection. 62 63 AMP 440 V ICTPN main switch 63 3 nos 63 Amp kitkat fuse on MS Board. 64 32 Amp main switch with all connections 65 Sub- main wiring 4 x 4mm2 copper wire with in 20mm dia pvc conduit. 66 Sub- main wiring 2 x 2.5mm2 copper wire with in 20mm dia pvc conduit. 67 Standard earthing in 38mm dia 3mtr long GI pipe with No 8 GI wire including all connections. 68 4 x 40 W F.L. Fitting complete with tube. 69 25 x 5 mm thick iron FL frame , ( 6.5 ft x 2.5 ft ) embeded on wall with all consumable materials like cement chips painting etc including all connections with PVC paint, flexible pipe,copper cable etc. 70 15 Amp switch and socket on 10 x 12 size MS board with all connections 71 RYB phase indicator with control 5 Amp F.T. switch with all connection. 72 5 Amp plug point on separate board fixed with 7 x 4 MS box with lylem cover with necessary connection. 73 Short point 74 10mm2 4 core cable 75 Ceiling Fan 76 PUMPING UNIT 77 Supplying installing, testing & commissioning of suitable vertical Sumersible pumping set of any repurted make such as KSB/Crompton/Greaves/ Kirloskar CRI/Suguna etc with energy efficient motor with ISI mark to run in 3 phase AC supply capble to discharge clear water from Intake well @2.85 lps against a total head of 80 mtrs. along with suitable pannel board of reputed make with ISI mark and 3 core flat submersible cable of reputed make with ISI mark . 78 5.00 HP 79 Supplying Testing ,and installation of suitable control pannel Board for suitable vertical submerssible pump and motor set with reputed ISI make. 80 Make BCH/L & T/Havels 81 Supplying, fitting & testing of 6mm2 three core flat submerssible electric cable reputed ISI make Finolex/BCH/Havells 82 Supplying, fitting & testing of required assessories like G.I R/S, stainless Steel nipple, G.I bend,wire ropw all of heavy quality with M.S calmp, MS bore cover etc. as required at site to complete the installation of the pimp set etc. complete in all respect. 83 Supplying of 50 mm dia HDPE suction pipe for lowering of pump & motors etc Please Enable Macros to View BoQ information
Contract Date: Jun 09, 2026 Contract Value : 15.06 Lakh
Government Departments No of Bidders 9
7.
Drinking Water Supply and Sanitation #11249728 AOC
Tender For pipe water supply To Kumar Limka Adivasi Sahi & Kumar Sahi Village:-Kumar Limka Adivasi Sahi Gp Padampur Under Koraput Block Under Dmf(2023-24) Programme- 1 CONSTRUCTION OF 50,000 LTR Capacity RCC OGR 2 Designing , construction, testing and commissioning of 50,000 ltr capacity circular shape flat bottom with domb shape RCC on the ground reservoir(OGR) including supplying , fitting, fixing of M.S and aluminuim ladder , water level indicator, lightening arrester 1 nos. 80 mm CI puddle collar-4, 2 nos. CI MH cover, Inlet & Outlet arrangement with 80 mm dia GI pipe - 18 mtr and soil testing & drawing design etc. testing of the joints all complete fitting and fixing 80 CI sluice valves-2 Nos, Sluice valve chamber -2 nos of standard make providing CC M-25 for RCC work with 20mm & down grade size hg chips with 20mm thick cement plater over the cement concrete work, cement punning over plaster surface and painting 2 coats of water proofing weather coat etc. all complete as per approved drawing and design as per direction of Engineer-in-Charge. 3 CONSTRUCTION OF PUMP HOUSE 4 Supplying all labour, T&P and materials for earth work excavation in foundation in all kinds of soil with all lead & lift including dressing the sides & levelling the bed of the foundation as directed by the Engineer-in-charges complete as per specification & direction of the Engineer-in-charge. 5 Supplying all labour, T&P and materials and providing Cement Concrete (1:4:8) in foundation and plinth with 4cm. H.G.Stone metal with cost, conveyance, royalty, taxes of all materials required for the work as per specification & direction of the Engineer-in-charge. 6 Supplying all labour, T&P and materials and providing R.R. H.G.Stone masonary with C.M.(1:6) in foundation and plinth with granite stone including cost, conveyance, labour, tax, royalty of materials to worksite complete as directed by the Engineer-in-charge. 7 Supplying, filling in foundation & plinth with sand in 15cms. (9) thick layers with the cost conveyance royalties, taxes of the materials complete as per specification and direction of the Engineer-in-charge 8 Supplying all materials, labour T&P providing R.C.C. (1:2:4) work using 12mm size hard black hand broken granite stone chips of approved quality and from approved quarry including hoisting lowering laying and compacting concrete watering and curing for four weeks, finishing the exposed surface smooth including cost conveyance taxes and royalty of all materials and labour with T&P required for the work etc, complete in all respect .as per specification and direction of the Engineer-in-charge.(Plinth Bend) 9 Supplying all materials, labour, T&P and providing Brick work with C.B Bricks in c.m (1:6) in superstructure using well burnt C.B bricks of size 23cm x 11cm x 8cm including cost, conveyance, royalty of all materials as per specification and direction of the Engineer-in-charge. 10 Supplying all materials, labour T&P providing R.C.C. (1:2:4) work using 12mm size hard black hand broken granite stone chips including cost conveyance taxes and royalty of all materials and labour with T&P required for the work etc, complete in all respect but excluding cost of MS Rods or Tor Steel and binding wires of 18 to 20 gauge as per including the cost of required quantity of centering and shuttering as per the dirction of the Engineer in Charge. 11 Lintel 12 Chajja 13 Straightening bend up or coiled rods cutting bending, cranking, hooking, welding or jointing (if required) the M.S. Rods or Tor Steel and binding wires and binding, tying the grills, hoisting, lowering and placing in proper position as required for R.C.C. works including cost, conveyance and taxes of M.S. Rods or Tor Steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc, complete in all floors as per specification and direction of the Engineer-in-charge. 14 Cost of M.S doors and windows : 15 Labour for fitting & fixing M.S. choukath to door & windows including making holes in the brick wall and fixing the clamps by using C.C (1:2:4) by using 12mm. size h.b.g chips with all cost, conveyance, labour, T&P etc., required for the work complete as per specification and direction of the Engineer-in-charge. 16 Supplying all materials, labour, T&P and providing 12mm (1/2) thick cement plaster (1:6) finished smooth with cost and conveyance of all materials as per specification and direction of the Engineer-in-charge. 17 Supplying all materials, labour, T&P and providing C.C. (1:2:4) work using 12mm size hard black broken granite stone chips including cost, conveyance, royalty & taxes etc, complete in all respect but excluding cost of M.S. Rods or Tor Steel and binding wires of 18 to 20 gauge as per specification and direction of the Engineer-in-charge. 18 Providing, fixing tiles in dados skirting and risers of steps on 12mm. thick cement plaster(1:3) jpinted with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing & polishing with cost, conveyance of all materials royalty, taxes etc, complete & as per the direction of the Engineer-in-charge. 19 Providing & fixing (Glazed) tiles in all floor & treads of steps & landing on 25 mm thick bed of cement mortar in proportion (1:1) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing & polishing with cost, conveyance of all materials royalty, taxes etc, complete & as per the direction of the Engineer-in-charge. 20 Supplying all materials, labour, T&P and providing 20mm (3/4) thick cement plaster (1:6) finished smooth to out side of stone work after raking out the joint including, watering and curing with cost and conveyance of all materials and labour with T&P ,all taxes and royalties etc., complete in all respect in all floors as per specification and direction of the Engineer-in-charge. 21 Supplying all material, labour, T&P and providing grading concrete with C.C(1:2:2) using 06mm. Size hard stone broken chips of approved quality including hpisting and laying not exceeding 25mm. thick with proper packing and required slope, with cost conveyance and taxes of all materials and labour with T&P required for the work etc, complete in all respect as per specification and direction of the Engineer-in-charge. 22 Supplying all labour, T&P and materials and finishing walls with two coats of weather coat over a coat of white wash with good shell lime with cost, conveyance, royalties and taxes of all the materials and labour with T&P required for the work etc, complete in all respect in all floors as per specification and direction of the Engineer-in-charge. 23 Painting two coats with any approved paint to new wood work and iron work including sand papering, polishing the surface, with cost conveyance and taxes of all materials and labour with T&P required for the work etc, complete in all respect including the the cost of appoved paint as per specification and direction of the Engineer-in-charge. 24 LAYING OF RISING MAIN 25 Earth work in excavation of trenches for laying of pipe line including dressing, leveling the bed upto required depth & within initial lead of 50mtrs & 1.5mtrs initial lift breaking clods to maximum size (5 to 7cm) laying in layers not exceeding 0.30mtrs in depth etc. complete including cost of all labour, T&P, pipes, fittings and specials etc.required for completion of the item as per specification & direction of Engineer in charge. 26 In all kind of Soil : (500.00mtr x 0.38mtr x 0.90mtr) 27 Supplying all materials including HDPE pipes, fittings and specials, labour, T&P for laying in trenches unplasticised HDPE pipes of the following outside diameter for all classes and specials as required at site, including jointing with solvent cement by non heat application method excluding the cost of earth work in excavation but including the cost of pipes cost of fitting and specials & testing the pipe line etc. all complete as per direction of Engineer-in-charge. 28 90 mm HDPE Pipe PE-80 PN-6 29 Supplying all labour, T&P for filling excavated earth in the pipe line trenches by laying in layers not exceding 9 (225mm) including watering and ramming as per the direction Engineer-in-charge. 30 In all kinds of soil : 31 Supplying all labour T&P fitting and fixing of CI sluice valves with double flanged ends in the water line for controlling purposes conforming to IS:14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including testing as per specicication complete 32 80 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 33 Supplying all labour, material, T&P and constructing brick masonry valve chambers of following mentioned inetrnal dimension, complete with C.C (1:4:8) with 40 mm size hbg metal at the bottom, C.B brick masonry in c.m(1:4) with internal plastering and R.C.C top cover with C.C(1:2:4) with 12mm size hbg metal & MS Rod 0.85qntl per 1 cum and with 12mm thick cement plaster (1:4) complete in all respect as per the direction of the Engineer-in-charge. 34 SluiceValve/NR Valve Chamber (Size 0.90mtr x 0.90 mtr x 1.15 mtr) 35 LAYING OF DISTRIBUTION SYSTEM 36 Earth work in excavation of trenches for laying of pipe line including dressing, leveling the bed upto required depth & within initial lead of 50mtrs & 1.5mtrs initial lift breaking clods to maximum size (5 to 7cm) laying in layers not exceeding 0.30mtrs in depth etc. complete including cost of all labour, T&P, pipes, fittings and specials etc.required for completion of the item as per specification & direction of Engineer in charge. 37 In all kind of Soil : (800 mtr x 0.38mtr x 0.90mtr) 38 Supplying all materials including HDPE pipes, fittings and specials, labour, T&P for laying in trenches unplasticised HDPE pipes of the following outside diameter for all classes and specials as required at site, including jointing with solvent cement by non heat application method excluding the cost of earth work in excavation but including the cost of pipes cost of fitting and specials & testing the pipe line etc. all complete as per direction of Engineer-in-charge. 39 63 mm HDPE Pipe PE-80 PN-6 40 Supplying all labour, T&P for filling excavated earth in the pipe line trenches by laying in layers not exceding 9 (225mm) including watering and ramming as per the direction Engineer-in-charge. 41 In all kinds of soil : 42 Supplying all labour T&P fitting and fixing of CI sluice valves with double flanged ends in the water line for controlling purposes conforming to IS:14846-2000 for the following rating and nominal diameters as per specifications complete of approved make with supply of all joining materials, T&P etc all complete including testing as per specicication complete 43 80 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 44 100 mm dia CI Sluice Valve IS- 14846/2000 PN-1.00 45 80mm CI NR Valve IS- 14846/2000 PN-1.00 46 15 mm dia CISingle Air Valve IS 14845/2000 47 Supplying all labour, material, T&P and constructing brick masonry valve chambers of following mentioned inetrnal dimension, complete with C.C (1:4:8) with 40 mm size hbg metal at the bottom, C.B brick masonry in c.m(1:4) with internal plastering and R.C.C top cover with C.C(1:2:4) with 12mm size hbg metal & MS Rod 0.85qntl per 1 cum and with 12mm thick cement plaster (1:4) complete in all respect as per the direction of the Engineer-in-charge. 48 SluiceValve/NR Valve Chamber (Size 0.90mtr x 0.90 mtr x 1.15 mtr) 49 Air Valve Chamber(Size 0.75mtr x 0.75mtr x 1.15mtr) 50 Supplying all materials, labout T&P pipes, fittings, push/rotary type water tap for construction of RCC single mouth stand post of size 250x250 mm platform of 1050x1050 mm with 3000 mm waste water drain as per approved drawing design and specification with CC M20 unsing 12 mm size h.g.c.b chips of approved quality from approved quarry including hoisting, laying and compacting and finishing the exposed surface smooth watering and curing including earth work in excavation in hard soil and rigid smooth centring and shuttering for cement concrete works along with MS Rainforcement as per specification including cost, royalty and conveyance charges of all materials etc. complete directed by Engineer in Charge. 51 Transporting and supplying all materials, labour T&P, fabricating, fitting and fixing with specials at the site using Electric resistance welded pipes of reputed make (TATA / Zindal ), confirming to IS 1239 (P-1) 2004, IS 1978 & IS 3598, medium quality & standard weight, including cutting the pipes & flanges, drilling the bolt holes in the flanges, matching the pipes and flanges and jointing with proper gradient & alignment, welding with arc welding using electrodes with power generated by using mobile diesel generator set, etc. complete as per direction of Engineer in charge, including painting two coats with black anti-corrosive paint over one coat of primer, all cost, conveyance, taxes of paints, cost of fittings as T, Bend, Offsets, Nuts and bolts, Leather packing etc. but including the cost of flanges and required earthwork, cutting holes in masonry works etc. 52 80 mm dia G.I pipe 53 INTERNAL ELECTRIFICATION 54 Supplying the following materials ,required labour and T &P and providing internal electrification to pump house as required at site including commisioning and testing as per the direction of the Engineer in Charge. 55 Surface wiring to light point in 20mm dia PVC cond. Pipe on MS board wiyh 3mm thick mulltistand copper wire. 56 a. Short point 57 b. Medium point 58 Surface wiring to 3pin 5A plug point in 20m dia pvc conduit on existing board . 59 surface wiring to 3pin 5A plug point in 20m dia pvc conduit on existing board . 60 Medium point 61 B.H. Fitting including all connection. 62 63 AMP 440 V ICTPN main switch 63 3 nos 63 Amp kitkat fuse on MS Board. 64 32 Amp main switch with all connections 65 Sub- main wiring 4 x 4mm2 copper wire with in 20mm dia pvc conduit. 66 Sub- main wiring 2 x 2.5mm2 copper wire with in 20mm dia pvc conduit. 67 Standard earthing in 38mm dia 3mtr long GI pipe with No 8 GI wire including all connections. 68 4 x 40 W F.L. Fitting complete with tube. 69 25 x 5 mm thick iron FL frame , ( 6.5 ft x 2.5 ft ) embeded on wall with all consumable materials like cement chips painting etc including all connections with PVC paint, flexible pipe,copper cable etc. 70 15 Amp switch and socket on 10 x 12 size MS board with all connections 71 RYB phase indicator with control 5 Amp F.T. switch with all connection. 72 5 Amp plug point on separate board fixed with 7 x 4 MS box with lylem cover with necessary connection. 73 Short point 74 10mm2 4 core cable 75 Ceiling Fan 76 PUMPING UNIT 77 Supplying installing, testing & commissioning of suitable vertical Sumersible pumping set of any repurted make such as KSB/Crompton/Greaves/ Kirloskar CRI/Suguna etc with energy efficient motor with ISI mark to run in 3 phase AC supply capble to discharge clear water from Intake well @2.85 lps against a total head of 80 mtrs. along with suitable pannel board of reputed make with ISI mark and 3 core flat submersible cable of reputed make with ISI mark . 78 5.00 HP 79 Supplying Testing ,and installation of suitable control pannel Board for suitable vertical submerssible pump and motor set with reputed ISI make. 80 Make BCH/L & T/Havels 81 Supplying, fitting & testing of 6mm2 three core flat submerssible electric cable reputed ISI make Finolex/BCH/Havells 82 Supplying, fitting & testing of required assessories like G.I R/S, stainless Steel nipple, G.I bend,wire ropw all of heavy quality with M.S calmp, MS bore cover etc. as required at site to complete the installation of the pimp set etc. complete in all respect. 83 Supplying of 50 mm dia HDPE suction pipe for lowering of pump & motors etc Please Enable Macros to View BoQ information
Contract Date: Jun 09, 2026 Contract Value : 15.06 Lakh
Government Departments No of Bidders 9
8.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
9.
Public Administrative Department #11187273 AOC
Tender For Safety Related Works At Maa Hospital, Postal Colony, Chembur E Mumbai. - Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, of 2820 LPM (Litres/min.) at 88m centrifugal type pump 2 SITC of Jockey Pump of 240 LPM at 88m head 3 SITC of Booster Pump of 450 LPM at 88 m head 4 415V Main Distribution Panel 1 short circuit reating 50kA for 1 Sec. 630A (Thermal magnetic overload, short circuit release & earth leakage module) MCCB with rotary operating mechanism as incomer with digital ammeter, voltmeter with selector switches, phase indicating lamp with required accessories, 1Nos. 63A, 3Noss. Of 100A, 2Noss. 160A & 200A (total 8Noss.) MCCB of short circuit rating 25kA for 1 sec. as outgoings. 5 Providing and fixing in position G.I. Heavy grade C class pipes 200 mm 6 Providing and fixing in position G.I. Heavy grade C class pipes150 mm 7 Providing and fixing in position G.I. Heavy grade C class pipes100 mm 8 Providing and fixing in position G.I. Heavy grade C class pipes 80 mm 9 Providing and fixing in position G.I. Heavy grade C class pipes 65 mm 10 Providing and fixing in position G.I. Heavy grade C class pipes 50 mm 11 Providing and fixing in position G.I. Heavy grade C class pipes 40 mm 12 Providing and fixing in position G.I. Heavy grade C class pipes 32 mm 13 Providing and fixing in position G.I. Heavy grade C class pipes 25 mm 14 Painting of 7 mtr G.I./M.S. Pole (All types). 15 Supplying & Installing cast iron double flange butterfly valve 200 mm 16 WAFER TYPE BUTTERFLY VALVES: -150 mm dia. 17 WAFER TYPE BUTTERFLY VALVES: -100 mm dia. 18 WAFER TYPE BUTTERFLY VALVES: -80 mm dia. 19 Supplying and installing double flange NRV 150 mm 20 Supplying and installing double flange NRV 80 mm 21 Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0- 14 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc 22 Supplying and installing pressure switch with 12/15 mm Ø isolation valve, G.I. nipple, elbow etc. in an approved manner as per specification 23 1st category Cu armoured cables FRLSZ outer sheathed- 3.5C x 35 Sq.mm 24 Cable End Termination For Aluminium Cables – 3C x 35 Sq.mm 25 Earthing Continuity Conductors -50 x 6mm GI 26 2nd category Cu armoured cables FRLSZ outer sheathed- 2C x 1.5 Sq.mm 27 50 x 50 x 6 mm of M.S.angle. 28 Supplying and installing fire brigade Header (Siamese Connection) of 150 mm Ø for supplying water to wet riser system as per specification 29 Supplying & installing moulded HDP / Fibre water tank. for -ve suction only, having capacity 1000 ltrs.fitted with necessary accessories complete as per specification 30 Supplying and erecting 20/25mm Ø G.M.air release cock, with necessary G.I. coupling to be fitted on top of Air vessel or on wet riser as per specification 31 Supplying and installing Air Vessel of 300 mm Ø 1.5m in height M.S. tank installed inside pump house as per specification 32 FIXING OF C.I. GATE VALVE COMPLETE WITH FLANGE, NUT, BOLTS ETC. -150 mm dia. 33 FIXING OF C.I. GATE VALVE COMPLETE WITH FLANGE, NUT, BOLTS ETC. -100 mm dia 34 Supplying and installing gun metal Double outlet hydrant valve fitted with necessary accessories 35 Supplying and installing gun metal single outlet hydrant valve fitted with necessary accessories 36 Supplying Stainless Steel branch Pipe 63 mmØ fitted with 20 mm dia detachable hexagonalnozzle as per specifications 37 Providing and fixing in position 2 lengths of 15 M long flexible canvas rubber lined hose reels 63 dia with adapter, branch pipe and nozzle and storing them in metal cabinets with lockable glass shutters and fixing the metal cabinet at ground level in a location where it can be easily spotted including painting etc 38 Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8x6) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour 39 Supplying and installing fire brigade Header (Siamese Connection) of 150 mm Ø for supplying water to wet riser system as per specification 40 Providing coating of Bitumen Paint & 4mm thick Wrapping as per IS 10221 for underground 100 mm Ring Main of Fire Fighting System. 41 Excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 Cu. Mtr. = 2.2 RMT. 42 Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m high pressure polypropylene (Polyhose) long fitted with necessary accessories complete as per specification 43 Cement concrete foundation using M-20 cement concrete mix with J shaped foundation bolts where required 44 Supply & Laying of double wall corrugated ( DWC) pipe 120 mm OD / 103.5 mm I.D. 45 Excavating the trenches and refilling the same after the cable is laid in approved manner (Size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 Cu. Mtr. = 2.2 RMT. And reinstatement. 46 Providing, detailing, composite fabricating members like Trusses, N-girders, girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using M.S. hollow tubular steel sections (circular & rectangular pipes), of TATA Structura Make or equivalent conforming to IS 1239 part 1 and 2 and of grade Fe 250 as per specifications and approved fabrication drawings (which are to be prepared by Contractor and got approved from Engineer), including transportion of the same to site, erection of structural steel members for all heights & at all levels, provision of necessary erection bolts, fixing bolts, nuts, washers, cleats, stiffeners, gussets, base plate, and all necessary operations like preheating as per specifications, straightening, bending, cutting, drilling, grinding, machining if specified, welding, grinding, removing the welding burr and preparing surface for painting with wire brush cleaning and applying two coats of epoxy red oxide zinc phosphate primer of 30 microns each and two coats of Epoxy Corrosion Resistant Enamel paint of 30 microns after fabrication including touching up with spray painting after erection etc complete as directed by Engineer In Charge. 47 Bare Galvalume/zincalume sheets for roofing 48 Rubber mat 2mm thick size 3x5 feet 49 Earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate & 50 mm dia. G.I. pipe, 3000mm long GI pipe (Class B or better) earth pit as per IS 3043. The earth pit shall be provided with watering pipe (Class B) with wire messed funnel, 25x3 GI strip/ / 2X8SWG G.I. wire up to chamber (wire or strip size as per fault level), disconnecting links with 600 x 600 mm (clear) RCC chamber & heavy duty 3mm thick CI chequered plate cover with hinge & stainless steel bolts. Bentonite/ Charcol & Salt shall be provided for earth pits. Excavation, back filling, removal of excess soil is included in the scope 50 Earthing Continuity Conductors -25 x 6mm Tinned copper 51 Earthing Continuity Conductors – Bare Copper Conductor size 12 SWG 52 45 Degree Leg Press (free Wts.) 53 Supply, Installation, testing & commissioning of addressable 2 loop main fire alarm electronic control panel, expendable up to 4 loop & having maximum 250 devices (any combination detectors plus devices) per loop & Audio/ Visual alarm complete as per IS: 2189 specification - modular type front operated with interlocking door arrangement totally enclosed dust and vermin proof for indoor type applications. 54 Supply, Installation, testing & commissioning of Active Repeater panel with all accessories, which shall be replica of main fire alarm panel with control keys I,e. Mute, silent & sounder alarm. 55 Supply, Installation, testing & commissioning of expandable Loop card for main fire alarm electronic control panel, shall support 254 devices both detectors and modules and shall support both class A & class B wiring. 56 Supply, Installation, testing & commissioning of Intelligent multi- criteria Detector along with mounting box & termination glands. 57 Supply, Installation, testing & commissioning of Intelligent Photoelectric Smoke Detector along with mounting box & termination glands. 58 Supply, Installation, testing & commissioning of Addressable Manual call point/ station with mounting back box 59 Supply, Installation, testing & commissioning of Addressable control Relay module with required accessories along with junction box, glands and terminators ( For AC trip off, Access trip off, PA system, sprinkler flow switch, lift interface, sounder, fire fighter & telephone jack) 60 Supply, Installation, testing & commissioning of Isolator Module along with mounting box & termination glands. 61 Supply, Installation, testing & commissioning of remote response indicator 62 Supply, Installation, testing & commissioning of Strobe Lights along with mounting box & termination glands. 63 Cable End Termination For Copper Cables – 2C x 1.5 / 2.5 Sq.mm 64 Supply, Installation, testing & commissioning of 2Cx1.5 sq.mm armoured RED color copper FRLS cable with necessary saddles, screws, junction boxes, sleeves, elbows couplings etc. for Fire alarm System 65 Supply and installation of Mixer amplifier 120W (4 channel input & 1 line level balanced output) 66 Supply and installation of Booster amplifier 300W with all accessories. 67 6W/100V. PA Ceiling Speaker 68 Delegate unit Microphone 69 Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver Paint. 70 SITC of Auto glow signage for Emergency Fire Exit 71 SITC of Auto glow signage for Do not use lift in case of Fire etc. 72 Clean Agent Fire Extinguisher 73 Fire B-Form Charges 74 Mock drill test (1st Year and 3rd Year) 75 CSMC 5% for 1st year 76 CSMC 5% for 2nd year 77 CSMC 5% for 3rdyear
Contract Date: May 29, 2026 Contract Value : 1.35 Crore
Local Bodies No of Bidders 3
Maharashtra View Result →
10.
Power #11168099 Price Bid
Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , St Pole 13 M- Is 410 Sp- 72 , Stay Set 16X1800 , Acsr Dog Conductor , Acsr Weasel Conductor , A.B.Cab. L.T. (3X95)+ (1X70)+ (1X16)Sq.Mm , A.B.Cab. L.T. (3X120) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Earth Rod 2540X20 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , 11 Kv Composite Polymer Pin Insulator , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Composite Polymer Pin Insulator , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Ms Channel 100X50 Mm , 33 Kv Cross-Arm 100X50 Mm V-Type , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Gi Wire 5 Mm/6 Swg , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Xlpe Cable Box 3X300 , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , 11 Kv Cable Box O/D 3X185sq.Mm , M.S. Angle 75X75x6 Mm , M.S. Angle 65X65x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , Stay Set 16X1800 , Stay Set Gi 20X1800 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , Ms Channel 100X50 Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Cross-Arm 100X50 Mm V-Type , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Disc Fitting 45 Kn (T&C) , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Composite Polymer Pin Insulator , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , Ms Angle 75X75x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection & Fixing Of Single Pole Structure Of Following Pole Of 11 Kv Line Along With X-Arm And Pin Insulator After Digging Of Suitable Pits Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , St Pole 13 Mtrs , Erection Of 11Kv Double-Pole Structure After Digging Of Suitable Pits On Following Pole With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , Erection Of 33Kv Double-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Tri-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Four-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection & Fixing Of 33Kv St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Grouting Of Following St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. , Plain Cement Concrete Pole 8.5 , Plain Cement Concrete Pole 11 Mtr. Long , Stp 13 Mtrs Long , Construction Of T/F Plinth Suitable For 160/250/400 Kva T/F (Size 2X2x1.5 Mtr) After Digging Of Earth And Construction With 14 Bag Cement, Fine Sand, Coarse.Sand, Brick Ballast, 1St Class Bricks 6000, Stone Ballast (40Mm), Ms Channel 125X65mm (54 Kg), Ms Twisted Bar 20 Mm (50 Kg) & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100/250 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , 250 Kva Transformer On Plinth , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Providing And Installation Of Maintenance-Free Chemical Earthing System For 250 Kva Distribution Transformer, Comprising Of Supply And Erection Of Approved Make Chemical Earth Electrode (Gi/Copper Bonded, Of Standard Length And Diameter) Installed In Drilled/Bored Hole Of Required Depth In All Types Of Soil, Including Backfilling With Highly Conductive Earthing Compound (Bfc/Graphite Based) To Achieve Low And Stable Earth Resistance; Providing Separate And Distinct Earthing For Transformer Body, Neutral And Lightning Arrester (If Applicable) Using Required Number Of Chemical Electrodes Interconnected Where Necessary; Construction Of Earth Pit Chamber With Brick Masonry, Plastering And Heavy Duty Ci/Rcc Cover With Provision For Watering/Inspection; Providing And Laying Of Gi Strip (E.G., 50×6 Mm) Or Suitable Copper Strip From Transformer Body, Neutral Point And La To Respective Earth Electrodes, Including All Connections With Nuts, Bolts, Washers, Lugs, Clamps And Anti-Corrosive Treatment; Testing Of Earth Resistance To Ensure Values Within Permissible Limits As Per Is/Respo Standards And Ensuring Long-Term Stability Without Frequent Maintenance; The Scope Includes Cost Of All Materials Such As Chemical Electrodes, Backfill Compound, Gi/Copper Strips, Bricks, Cement, Sand, Covers, Water, Etc., And All Labour, Drilling, Installation, Refilling, Carriage, Loading/Unloading, Handling, Testing, Commissioning And All Tools & Plants (T&P) Required For Complete And Satisfactory Execution Of Work As Per Standard Specifications And Direction Of Engineer-In-Charge. , Construction Of Safety Fencing (Ms) Size 3X3x2 Mtr. For Dist. Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50x3 Mm) M.S. Wire Mesh Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Angle/T-Iron To Be Fitted On Vertical Posts. Pickets (If Required) Fitted To Rail And Gate To Facilitate Entry And Exit. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Angle 65X65x6mm. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Providing, Installing, Testing And Commissioning Of Tailless Unit Suitable For 250 Kva Distribution Transformer, Including Dismantling Of Existing Tail Connections (If Any), Supply And Fixing Of Required Lt/Ht Connectors, Busbar Arrangements, Insulated Sleeves, And Necessary Termination Accessories; Complete Modification Of Transformer Lt Side To Tailless Configuration Ensuring Proper Phase Segregation, Insulation And Mechanical Strength; Including Providing And Fixing Of Suitable Size Aluminium/Copper Lugs, Glands, Ferrules, Heat Shrink Sleeves, Pvc Insulation Tape, Nut-Bolts, Washers And All Jointing Materials As Required; Making Proper Cable Terminations, Dressing And Clamping Of Cables With Gi Clamps; Providing And Ensuring Effective Earthing Of The Tailless Unit With Gi Strip/Wire And Connecting To Existing Earthing System; Including Painting Of Modified Portion With Suitable Anti-Corrosive Paint; Complete Testing For Continuity, Insulation Resistance And Proper Load Transfer; The Work Shall Be Carried Out As Per Relevant Is Standards, Respo/Departmental Specifications And As Directed By Engineer-In-Charge; The Rate Shall Include Cost Of All Materials, Labour, Tools & Plants (T&P), Handling, Loading/Unloading, Transportation, And All Incidental Works Required To Complete The Job In All Respects. , Providing, Laying, Jointing And Commissioning Of 140/200 Mm Dia (Od) Pn-4, Pe-80 Grade Uv Stabilized Hdpe Pipe In 6.0 Mtr Standard Length By Trenchless (Hdd/Drilling) Method For Underground Cable Protection, Including Excavation Of Suitable Size Launching And Receiving Pits, Alignment And Preparation Of Bore Path, Drilling, Reaming And Insertion/Pulling Of Hdpe Pipe, Jointing By Butt Fusion/Electrofusion With All Necessary Fittings Such As Couplers, Bends And End Caps, Ensuring Proper Alignment And Leak-Proof Joints; Including Providing And Laying Of Warning Tape, Route Markers And Identification System; Complete With All Required Tools & Plants (T&P) Such As Hdd Machine, Drilling Machine, Compressor, Generator, Welding Machine, Including All Consumables, Loading/Unloading, Handling And Safe Stacking At Site; Including Dewatering (If Required), Traffic Control, Barricading And Safety Measures; Also Including Restoration Of Road, Footpath, Drain Or Any Other Surface Under Row (Right Of Way) Conditions To Original Condition And Disposal Of Surplus Earth/Muck; Complete In All Respects As Per Relevant Is Standards, Respo/Departmental Norms And Direction Of Engineer-In-Charge, With All Material, Labour, T&P, Transportation And Incidental Charges Included In The Rate. (Rate Will Be Charge As Per Actual Length Of Work) , 200 Mm Dia For 33 Kv Line , 140 Mm Dia For 11 Kv Line , Laying Of Following Cable Undergound Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape At Both Ends As Per Respo/Norms, As Per Direction Of Site Incharge.(Rate Will Be Charge As Per Actual Length Of Work) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Manually Digging Excavation Of Trench Of Size 0.50 M Width × 1.00 M Depth In All Types Of Soil Including Dressing, Levelling And Disposal Of Surplus Excavated Earth Within Specified Lead As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Supplying And Laying Of Brick Masonry (Class Designated) In Cement Mortar For Side Protection, Providing And Filling Of Sand Cushioning At Bottom And Around The Laid Cable, Followed By Laying Of Plain Cement Concrete (Plain Cement Concrete) Of Required Grade For Base And Protective Covering Over Trench; Thereafter, Placing And Proper Alignment Of Xlpe Cable Within The Complete Trench, And Covering The Trench With Brick/Cc Slab Protection Including Backfilling With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; The Scope Of Work Includes Cost Of All Labour, Materials (Bricks, Sand, Cement, Aggregates, Water Etc.), Handling, Loading/Unloading, Carriage, And All Tools & Plants (T&P) Required For Excavation, Laying And Finishing Works, With All Safety Precautions, As Per Standard Specifications And Directions Of Site In-Charge. (The Firm Will Be Fully Responsible For This Work And Taking Necessary Permission), As Per Direction Of Site Incharge (Rate Will Be Charge As Per Actual Length Of Work). , Laying And Installation Of 11 Kv Grade, 3 Core × 185 Sq.Mm Xlpe Insulated, Armoured Aluminium Conductor Cable In Underground Trench In Double Circuit Formation, Including Careful Handling, Dressing And Alignment Of Cable Along The Route As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Laying Of Cable Over Prepared Sand Bed, Maintaining Proper Spacing Between Circuits, And Ensuring Identification And Phase Marking; Providing Extra Length Of Cable At Both Ends In Loop Formation For Future Jointing/Termination (Spare Cable To Be Left In Loop Shape At Each End) As Specified; Covering Of Cable With Sand Cushioning, Protective Bricks/Tiles/Cc Slabs And Backfilling Of Trench With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; Including Supply Of All Consumables Such As Sand, Bricks, Cable Markers, Route Indicators, Etc., And All Labour, Loading/Unloading, Carriage, Handling Charges, Testing Prior To Commissioning, And All Tools & Plants (T&P) Required For Safe And Proper Execution Of Work As Per Standard Specifications And Site Instructions. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, As Per Direction Of Site Incharge. , Making And Filling Of 11Kv/33Kv Cable Jointing Kit, Indoor/Outdoor Type, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , 11Kv Cable Jointing Kit 3X185 Sq.Mm. , 33Kv Cable Jointing Kit 3X300 Sq.Mm. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying , Stringing And Final Sagging Of Acsr Dog Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying And Stringing Of Following Lt Aerial Bunched Cable (Abc) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Lt Aerial Bunched Cable (Abc) (3×95 + 1×70 + 1×16 Sq.Mm) , Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 4Mm/ 8 Swg , G.I. Wire 5Mm/ 6 Swg , Grouting & Fixing Of Stay Set (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Stay Set (16X1800) , Stay Set Gi (20X1800) , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Dead & Clamp , Suspension Clamp , F-Bracket With Clamp , Cross Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Fuse Set Complete On 25/63/100 Kva Transformer In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad 300X300x75 Of Approved Quality And Specified Size At Pole/Support Locations, Including Excavation Of Suitable Size Pit, Preparation Of Base, Dressing, Leveling, And Proper Placement In Line And Level As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge, Including Refilling, Ramming And Consolidation To Ensure Stability; The Scope Of Work Includes Cost Of All Labour, Loading/Unloading, Carriage, Alignment And All Incidental Works Required For Complete Execution, And All Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable M.S. Clamp, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site, And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Barbed Wire Of Approved Quality And Specification In Position, Stretched And Secured On Poles/Structures With Suitable Binding Wire, Staples, Clamps Or Other Approved Means, Maintaining Proper Tension, Alignment And Height As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing, Tightening And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Stay Insulator Of Approved Make, Type And Rating In Stay Set Assembly, Including Proper Placement Between Stay Wire Lengths, Making Necessary Connections, Tightening And Ensuring Correct Alignment And Insulation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of I-Bolt Of Approved Size And Quality For Guarding Angle, Complete With Nuts, Bolts, Washers And Necessary Accessories, Including Drilling Of Holes In Angle/Pole As Required, Proper Insertion, Fitting, Tightening And Ensuring Correct Alignment And Rigidity As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Number Plate Of Approved Size, Design And Material With Proper Painting/Printing Of Identification Number And Lettering, To Be Securely Mounted On Pole/Structure At Suitable Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fixing With Suitable Clamps, Nuts, Bolts Or Binding Wire As Required, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Necessary For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Draw Out Fuse Set Of Approved Make And Rating, Complete With All Standard Accessories, Mounted On Pole/Structure With Suitable Clamps, Nuts, Bolts And Connectors, Including Proper Alignment, Tightening And Making Necessary Electrical Connections For Safe And Reliable Operation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Erection, Testing And Commissioning And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment, Tackles And Testing Instruments Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Smc Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable Clamps, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Paint And Carrying Out Painting Of Pole With Approved Quality Paint System, Including Thorough Surface Preparation By Cleaning, Scraping, Wire Brushing And Removal Of Rust, Dirt And Loose Materials, Applying Primer Coat Where Required And Finishing With Two Or More Coats Of Approved Paint Of Specified Shade, Including Marking/Numbering If Directed, Complete In All Respects As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage Of Materials To Site And All Incidental Works Necessary For Satisfactory Completion, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Construction Of Meter Room Of Internal Size 8× 8× 10 Height, Including Setting Out, Excavation Of Foundation In All Types Of Soil, Dressing And Disposal Of Surplus Earth Within Specified Lead; Providing And Laying Plain Cement Concrete Of Required Grade For Foundation Base, Followed By Construction Of Brick Masonry In Cement Mortar Of Approved Class For Foundation And Superstructure Walls Of Required Thickness, Including All Leads And Lifts; Providing Reinforced Cement Concrete Lintel And Roof Slab (Solid Slab) Of Required Thickness Using M-20 Grade Concrete With Centering, Shuttering, Vibration And Curing Complete, Including Reinforcement Steel As Per Design; Providing Internal And External Plastering In Cement Mortar Of Required Thickness, Smooth Finishing, And Curing; Providing Flooring With Cement Concrete Or Ips Finish, Including Base Preparation And Finishing; Supplying And Fixing Of Ms/Steel Door With Frame, Including Holdfasts, Hinges, Locking Arrangement And Painting; Providing Ventilators With Ms Grill, Including Fixing; Complete Internal And External Painting/Whitewashing With Approved Quality Paint; Providing Necessary Provisions For Meter Installation Such As Cable Entry Points, Sleeves, Earthing Arrangement, Foundation Bolts And Fixtures; The Scope Includes Cost Of All Materials Such As Bricks, Cement, Sand, Aggregates, Steel, Doors, Grills, Paint, Water, Etc., And All Labour, Tools & Plants (T&P), Scaffolding, Curing, Carriage, Loading/Unloading, Handling And All Incidental Works Required For Complete Construction As Per Standard Specifications And Direction Of Engineer-In-Charge. , Laying Of Power/Control Cable Of Specified Size In Trench/Duct/On Surface Along Approved Route, Including Excavation Of Trench, Sand Cushioning, Proper Dressing, Alignment, Clamping, Identification Tagging, Protective Covering With Bricks/Tiles (Where Required), Backfilling, Ramming, Leveling, And Disposal Of Surplus Earth; Including Handling, Shifting, Straightening, And Pulling Of Cable With Due Care To Avoid Damage And Maintain Required Bending Radius; Complete In All Respects As Per Standard Specifications And Direction Of Engineer-In-Charge, All Materials, Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
11.
Defence #11167640 AOC
Tender For Provision Of Single Men Barracks Including Cook House For Agniveers At Brc, Danapur.; 1 SCHEDULE A Part-I (Building/Structures) (To be quoted by the tenderer) 2 Item No 01 A : Design and construction of 180 ORs SM BarrackComplete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 3 Item No 01 B: Design and construction of Dinning Hall Complete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 4 Item No 01C : Design and construction of Cook House Complete allspecified in soil bearing capacity report, design basis report, drawings and tender documents. 5 Sch A Part-II (Internal Electrification)Lump sum price worked out by the contractor for (Internal Electrification) as listed in Schedule A Part-II against the lump sum price inserted by the MES. 6 Sch A Part-III (External Electric Supply)Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule A Part-III against the lump sum price inserted by the MES. 7 Sch A Part-IV(External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 8 Sch A Part-V(Road, Path Curvert)Lump sum price worked out by the contractor for (Road, Path Curvert)as listed in Schedule A Part-V against the lump sum price inserted by the MES. 9 Sch A Part-VI (Air Conditioning)Lump sum price worked out by the contractor for (Air Conditioning) as listed in Schedule A Part-VI against the lump sum price inserted by the MES. 10 Sch A Part-VII(Refrigeration System)Lump sum price worked out by the contractor for (Refrigeration System) as listed in Schedule A Part-VII against the lump sum price inserted by the MES. 11 Sch A Part-VIII((FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM)Lump sum price worked out by the contractor for ((FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM) as listed in Schedule A Part-VIII against the lump sum price inserted by the MES. 12 Sch A Part-IX(Demolition of Bld (B/R) Lump sum price worked out by the contractor for (Demolition of Bld (B/R)as listed in Schedule A Part-IX against the lump sum priceinserted by the MES. 13 Sch A Part-X(Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal)as listed in Schedule A Part-X against the lump sum priceinserted by the MES. 14 Sch A Part-XI(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule A Part-XI against the lump sum price inserted by the MES. 15 Sch A Part-XII(Site Clearance) Lump sum price worked out by the contractor for (Site Clearance)as listed in Schedule A Part-XII against the lump sum priceinserted by the MES. 16 Note for Srl No 2 to 15The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 14by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 17 Schedule A Part-XIII (Miscellaneous items of works) 18 INTERNALELECTRIFICATION 19 Item No 02 : Materialand labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade(MMS/HMS) andincluding cutting, chasing work at any height and all accessoriesconcealedinwalls / roofs / floors / ceiling etc. 20 flush mountingMS box with top,bottom,side/back wall knockout for conduitentry from any direction made out of 1.60mm thick suitable for fixing of andincludingwhite/Silver/Dark bronzecolour modular blankingplate as per number of switch modules flush mountedfor fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colourmodular plate cover of required modules andincluding 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing complete all as specified and directedfor the following:- 21 (a) One light point controlled by one switch. 22 (b) Onefan point controlled by one switch and oneregulator. 23 (c) Oneexhaust fan point controlled by one switch . 24 (d) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . 25 (e) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . 26 (f) One bell/buzzer point controlled by one bell push. 27 (g) One light point controlled by two 2 way switches. 28 Item No 02 : All as per item No.1(d) & (e) above,but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- 29 (a) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switchon independent board. 30 (b) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board. 31 Item No 03 :All as per item No.1 (d) above ,but point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed. 32 Item No 04 : Supply & fixingand sheet metal enclosurewith acrylic door type, double door ,415 volts AC,VTPNDB, 4 way,8+12 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bars links and MCCB incomer,and MCB SPN/SP/TPNas outgoing and complete forIP43&54 DBs protection complete all as specified and as directed. Note for item No.22 to 32- MCCB/MCB DBs and MCBs/MCCBs both are used same make only 33 Item No 05: Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old item completeall as specified and directed. 34 External Electric supply 35 Item No 06 :Supply, installation, testing and commissioning of step down copper wound transformer of capacity 315 KVA (Energy Efficient LEVEL 3 ), outdoor type, plinth platform of min size 2.4 x 2.4 x 1.5 Mtr (Solid PCC Block) complete with standard fittingts and accesswories, HT 11 KV 3 phase, Lt 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 (Part-I)-2014 (latest edition) with amendment no. 1,2,3 & 4 (Level 3). oil cooling with fins vector group: DYN 11, incl initial oil fitting complete all as specified incl the following accessories:- 36 a) three numbers porcelain bushing HT, 11KV with Brass bushing Rod, Nuts, bolts and washers etc inside cable end box b) One cable box LT side consisting of 4 numbers porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT UG cables c) Oil conservator with filter type drain valve and oil level guage 37 d) Dehydrating breather with fast feel of dehydrating agent e) Explosion Vents f) thermometer pocket on tank cover g) Rating Plate on terminal marking plate h) Earthing arrangement i) Oiil drain filter valve j) Oil Drain Valvek) Lifting Hook 38 l) Oil conservator with filling hole and capm) Air release valve plugn) Four plate solid cast steel detachable rollerso) Buchholz relay p) Earth Bushing for neutral Outside the cable box for neutralq) Suitable size of channel on foundation for fixing the transformer with jint and stopper(r) Plateform for mounting of transformer made up of PCC 1:2:4, 20 mm graded stoen aggregate, solid block and making all faces fare using extra cement as per manufacturer design of required length, width and hight in and including providing of 02 nos ISMC 100 chanel embe3dded in PCC of wuitable length as directed at site by the engr in charge in and including earth work complete. 39 Note: (i) Anything missed out above but technically required for proper operation of transformer is deemed to be included in the quoted rate. 40 Item No 07 : Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. 41 Item No 08 : Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3½ core complete all as specified and as directed. 42 Item No 09 : Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3½ core complete all as specified and as directed. 43 Item No 10 : Supply and fix cable jointing kit for 1.1 KV grade cable for straight through/ end terminal joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 95 sqmm,Indoor/Outdoor type complete all as specified and as directed. 44 Item No 11 : Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved ,feeder piller box of made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical legs frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. 45 Incoming (a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 35 KA breaking capacity, rating 400 Amps including all fixing accessories with both ends spreader links-01 No. (b)Digital voltmeter of range (0-500) volts, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(c)Digital Ammeter of range (0-250) Amps, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No.(d)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three). 46 Outgoing(a)MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 250 Amps including all fixing accessories with both ends spreader links-01 No. 47 (b)MCB,4 pole, 415V, C series rating 200Amp Amps including all fixing accessories with both ends spreader links-02 No. (01 + 01 spare) 48 (c ) Copper strip busbar of 600 Amps current carrying capacity with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 nos. 49 (d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. 50 Item No 12 :M&L for Shifting of existing VCB from existing location near pump house No:2 over head tank to proposed building approx 300 Mtr with the help of crane including necessary T&P including Servicing, comprising of overhauling and refixing the same after repairs: (a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection.(b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required. 51 (c) Servicing/Inspecting/checking ofcircuit spoutand cicuit spout connections for RYB phases and replacement of spares if required.(d) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. (e) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (f)Servicing/Inspecting/checking ofsecondary sockets/busbar earthing plugs/earthing sockets and replacement of spares if required. 52 (g)Checking, setting and adjustment of lowering and raising operation of the breaker trolley. (h)Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly. (j) The inspection of HT switch gear shall involve:-(i) Inspection of truck & hoist assembly.(ii) Inspection of tank assembly & barriers.(iii) Inspection of assembly & components of solenoid assembly.(iv) Inspection of assembly & components of dependent mechanism.(v)Inspection of assembly & components of spring box mechanism.(vi)Inspection of motor mechanism spring charge assembly (vii)Inspection of assembly of trip unit & related components.Notes: (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound and any damaged parts etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. 53 Item No 13 : M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. 54 Item No 14 : M&L Costruction of a 18 sqm room with a height of 3.5 mtrs, designed to house a vaccum circuit breaker (VCB). The costruction will include foundation work, walls, roofing , flooring, plastering and miscellaneous items like windows and doors. complete all as specified and as directed. 55 External Water Supply 56 Item No 15 : M & L for Construction of brick masonry valves pits , of the following internal dimension complete with 3015mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC wok complete. 57 (a) 900mm x 900mm x 900mm 58 (b) 600mm x 600mm x 600mm 59 Item No 16 : Refixing MS/ GI/ CI DI pipe any type and connections in new or old position including cleaning internally and externally, any grade / make (in trenches) including all type of new fittings i.e. sockets, Tee, union, elbow etc complete all as specified and as directed. 60 (a)100 mm dia 61 (b) 150 mm dia 62 Item No 17 : Supply and fixing in replacement ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on joint (rubber gasket D jointing) in any length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for distrubed surfaces of roads, pathways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, excavation of pipe line, connections etc complete all as specified and as directed. (a) 150 mm dia 63 Refrigeration System 64 Item No 18 : Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres .BEE 5 star rated complete all as specified and directed. 65 Item No 19 :Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA. 66 Water cooler 67 Item No 20 : Supply, installation and Commissioning water cooler, Electric driven,(single phase 230 volts) having approx storage capacity of 120 Litres and nominal cooling capacity of 60 Litres per hour complete all as specified. 68 Item No 21 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified. 69 Air Conditioning 70 Item No 22 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified. 71 Hot Water Supply 72 Item No 23 : Supply and fix Water heater storage type, electric,capacity 50 litres.BEE 5 star rated 73 Item No 24 : Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece complete all as specified and directed. 74 Dessert Cooler 75 Item No 25 : Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Steel body type complete all as specified and directed. 76 Electric Chimney 77 Item No 26 : Supply, installation testing and commissioning commercial kitchen chimney stainless steel body with filter size 96 X 30 including 1 HP exhust fan, Air outlet duck of chimney G.P sheet 0.50 mm thick of size 22 X 22 X 15 ft long complete all as specified and directed. 78 FIRE FIGHTING SYSTEM(DOWN COMMER) & FIRE ALARM SYSTEM 79 Item No 27 : Supply only of fire extinguiser ISI marked CO2 type Fire Extinguisher 4.5 KG capacity conforming to IS : 15683 :2006 (old IS : 2878) made from seamless cylinder conforming to IS : 7285 duly approved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve conforming to IS : 3224 , high pressure 1 mtr long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket, , suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 138. 80 Item No 28 : Supply only of stored pressure fire extinguiser ISI marked powder type Fire Extinguisher 4 KG capacity suitable for Class A, B, C Fire consisting with discharge hose and nozzle of welded cylinder, squeeze lever discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nozzle suspension bracket conforming to IS : 15683 :2006 (old IS : 2878) duly charged with ISI Marked Mono Ammoniumphosphate base ABC powder conforming to IS : 14609 and pressurized with Nitrogen Gas, suitable for operating between 30 degree centrigrade to + 55 degree centigrate, Fire Rating Class - 1A & 13B 81 Item No 29 : Supply only of Fire bucket iron body red colour 10 L capacity for dry sand stored type ISI MarkedIS : 2546 :2006, complete all as specified and as directed. 82 Item No 30 : Supply only of Fire Extinguisher Mechanical Foam type ISI Marked Foam (AFFF) type Fire Extinguisher 9 ltrs capacity fitted with Forged Brass squeeze lever discharge valve, conforming to IS : 15683 :2006, complete with initial refill consisting of ISI Marked CO gas cartridge of 60 gms capacity conforming to IS 4947 and ISI Marked AFFF conforming to IS : 4989, suitable for operating between + 50 degree centrigrade , Fire Rating Class - 3A & 34B 83 Sewage Disposal 84 Item No 31 : M&L for DWCPE (SN8) pipes 180 OD/163 ID, laid and jointed complete complete all as specified and directed for the following internal dia of pipes. 85 Item No 32 : Construction of Conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, Base slab, Baffle walls and roof slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users conventional type. 86 Item No 33 : Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia X 3.0 M effective depth. 87 SCHEDULE A(Schedule of credit)Schedule of Credite Rs 50001.00 (Minus) inserted by the MES.(Note : Credit amount shall be deducted manually to arrive net bid amount)
Contract Date: Jun 27, 2026 Contract Value : 10.28 Crore
Statutory Bodies & Commissions/Committees No of Bidders 10
12.
Defence #11150449 AOC
Tender For Provision Of Offers Mess Under Ge (N) Udhampur; 2 Construction of block of Offrs Mess complete all as shown on drawings and as specified. 3 Construction of block of Servant Quarter complete all as shown on drawings and as specified. 4 Construction of block of Car Garage (09 Cars) complete all as shown on drawings and as specified. 5 TotalAmount of Sch A Part - II (Internal Water Supply Work) 6 TotalAmount of Sch A Part - III (Internal Electric Supply Work) 7 TotalAmount of Sch A Part - IV (Plumbing Work) 8 TotalAmount of Sch A Part - V(Area Drainage Work) 9 TotalAmount of Sch A Part - VI (Sewage Disposal Work) 10 TotalAmount of Sch A Part -VII (Road, Path, Culvert and Hard Standing Work) 11 TotalAmount of Sch A Part - VIII (External Water Supply Work) 12 TotalAmount of Sch A Part - IX (External Electric Supply Work) 13 TotalAmount of Sch A Part -X (Compound Wall , Fencing and Gate Work) 14 TotalAmount of Sch A Part -XI (Hot Water Supply Work) 15 Sch A Part - XII (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 16 Construction of septic tank for 50 users (Brick construction) complete all as shown on drg No. CEUZ /TD-1585/2021 sheet 1/4 to 4/4 and as specified. 17 Construction of soakage well (Brick construction) 1.8m dia and 3.0m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. 18 Supply, installation and comminssioning of water cooler, fully stainless steel, electric driven single phase having storage capacity 120 litres and nominal cooling capacity of 60 Litres per hour, fitted with hermetically sealed air compressor operating on refrigerant R-134a or 410a, conforming to IS-1391 Part-II) complete all as specified and directed. 19 Supply, installation and comminssioning of refrigerator, double door BEE 5 star rated frost free, digital inverter with hermetically sealed compressor of min capacity 256 litres suitable to use on 230 volt, AC supply complete all as specified and directed. 20 Supply, installation and comminssioning of metal top deep freezer BEE 5 star rated hard top having capacity 320 litres, double door, single phase 240 V, 50Hz, complete all as specified and directed. 21 Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed. 22 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating inverter technology and EER 3.2, single phase, capacity 1.5 TR, complete all as directed. 23 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating inverter technology and EER 3.2, single phase, capacity 2.0 TR, complete all as specified and directed. 24 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed. 25 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. 26 Supply, installation, testing and commissioning of solar hot water heating system (Flat plate collector) based on indirect transfer of heat for 300 liters as per IS-12922 and IS-12978 with electrical backup of 2KW, including angle iron support (60mmx60mmx6mm) with nut, bolts, washers and painting with two coat of synthetic enamel paint over one coat of red oxide primer for mounting of hot water plant and cold storage tank, complete all as specified and as directed.Note:- Cold water storage tank shall be measured and paid separately. 27 Construction of valve pit of size (90x60x60)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 coping with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts in coping including painting of steel surface with two coats of synthetic enamel paint over a coat of redoxide primer as finishes coat including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed. 28 Supply , installation, testing & commissioning of transformer of capacity 100KVA step down outdoor type level - III, copper wounded, 11/0.433KV (at no load) AC 3 phase, vector group Dyn 11, 50HZ on secondary side double wound oil immersed naturally air cooled with external cooling tubes /radiator , delta connected as on primary and star connected with netural brought out on secondary side and having tapping at -2.5% to +7.5% in steps of 2.5% to be changed by external hand operated self position off load tap change switch. Also provision shall be made for locking the taping switch handle in position. The maximum temperature rise shoud not exceed 35 degree centigrade on top of oil when measured on thermometer and 40 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirming to IS 1180-2014 transformerlossess shall be as per latest ammendment No IV as per IS 1180 part - I 2014 and comprising of following accessories complete all as specified and as directed. (Contd.../) 29 a) 03 No porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods nuts.b) 01 No cable end box on LV secondry side consisting of 05 No porcelain bushing (One No neutral earth, One No Neutral and 3 No for phaseconnected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 400 Sqmm cable 3 runs, LT 1100 V grade XLPE insulated heavy duty including gland joint complete. c) Oil conservator with filter type drain valve and oil level guage.d) Dehydrating breather with first filling of dehydrating agent e) Explosive vent.f) THERMOMETER pocket including temperature gaugeg) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strips.(Contd.../) 30 h) OneNo thermometer dail type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge : Max reading painted terminal.i) Rating plate with terminal plate.j) Oil level guage.k) Oil drain filter valve.l) Oil filling hole on top cover with plug.m) Air release valve/plug.n) 4 Nos plain solid cast steel detachable rollers. o) First fill of tranformer oil conforming to relevent ISI and tested upto 60 KV dielectric strength.p) Two No lifting hook at side of transformerNote : Transformer must be as per Energy efficiency Level-3 of IS: 1180:2014 with amendment No. 4. 31 Construction of PCC platform for transformer of size 3m x 3m and 1m high from ground level with brick construction in walls and steps, PCC 1:5:10 type E-2 in foundation, brick workin CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushedstone aggregate). In flooring40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer complete duly surrounded with XPM fencing of length not less than 15 meter and width not less than 10 meter complete with 40mmx5mm angle iron & 12mm dia steel bars, fixed on PCC gate pillers complete including sliding bolt, locking arrangements hinges and all accessories,shown on drawing No CE/TD/1129/96 sheet No. 1/2 & 2/2complete all as specified. 32 Earthing complete with galvanized steel earth plate electrode600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 33 10W decorative inverted tripod type LEDBollard with IP-65 protection, soft 360 degree light distribution body made of die cast aluminium & in triangular shape including 10 W LED with IP 65 ingress protection, 4 KV surge protection, Luminaire should have high efficiency isolated poted driver minimum height of bollard 800mm & with 180mm OEM should have inhouse NABL approved Lab & submit LM-79 report along with NABL certificate, PCC foundation with necessary nuts & bolts complete all as directed by GE. 34 Post top lantern, LED type, 40 watt including40 watt LED AC, outdoor type with decorative post top for 360 degree indirect light IP 66 protection with impact, glare free and better uniformity and corrosion resistant, LED driver shall be constant current type potted driver, luminaire shall have surge protection devices of minimum 10KV inside the driver compartment. Total harmonic distortion shall be <10% with power factor minimum 0.95.The driver shall have an effiviency>85%. It should give consistent performance in the input voltage range of 120V-270V at 50Hz, luminaire shall be embossed or screen printed with manufacturer name/logo, OEM should have in house NABL approved lab and submit LM79 report along with NABL certificate, PCC foundation with necessary nuts and bolts complete with driver and lamp complete all as specified and as directed. 35 Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 36 Sintex box of size 155mmX210mmX92mm, hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cablefor phase and neutral fixed on polewith the help of MS nuts bolts and MS clamps; 2 No of size 40mm X 4mm thick, with one No MCB SP 6 Amp capacity mounted on din rail inside box, including making suitable hole in pole to take out connections to fitting if required at site and provisioning of conector of street light, complete all as specified.Make:- Hensel, Sintex or equivalent make approved by GE. 37 LED street light fitting 70 Watt, 230 V, AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed. 38 Supply, installation, testing and commissioning offactory made outdoor type CPRI approved dust and vermin proof LT panel board front opening (double shutter) with locking arrangement of suitable size made out of 3.15 mm thick CRCA sheet with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring,thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1)of suitable size as per panel board 0.5mtr above ground level grouting and bottom portion of enclosure shall be minimum 30cm above ground level of legs of angle ironand supply & comprising of the following including internal pre-wiring complete:- 39 INCOMING(i) MCCB 4 pole 160 Amp 16 KAKA thermal magnetic adjustable type- 01 No. (Incoming) (ii) Voltmeter 0-500 V with selector switch(Digital type) - 01 set. (iii) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set(iv) Indicator lamp neon/ LED type RBY -01 Set of three.v) Aluminium bus bar capacity 250 Amps for Phase-R-Y-B- N - 4 No.OUTGOING:(i) MCCB 3 pole 125 Amp 16 KA thermal magnetic adjustable type -02 No. (Outgoing)(ii) MCCB 3 pole40 Amp 16 KAKA thermal magnetic adjustable type01 No. (Outgoing)(iii) MCB SPN 32 Amps 10 KA - 01 No (Outgoing)(iv) Time switch 250 V single phase of 20 Amp rating - 01 No(v) Complete wiring of the panel board with FRLSH PVC insulated multistrand copper conductor cables of suitable current carrying capacity end terminated with lugs and bolts, nuts and washers of galvanised iron.Note: The rate quoted should include the cost ofexcavation/PCC work as per manufacturers recommendation. 40 Bracket made out of GI tubing 40mm dia, light grade 1.5mtr long including fixing withMS clamps - 2 No made out of 50mm wide, 5mm thick, flat iron with M.S nuts bolts 75 mm long 12mm dia, - 4 No with flat washer (3mm thick) - 02 No including painting with two coats of aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete, including 1.5sqmm 3.0 core, flexible Copper cable from juction box to connecter of street light fitting complete all as specified and as directed. . 41 Cable route marker with route indication at every 30m length on cast iron disc of 100mm dia and 5mm thick, marked/written for HT cable 11000 VOLTS embosed including indication direction fixed/bolted to 40mm x 40mm x 6mmthick MS angle iron support of 0.50 m long embedded upto 200mmdepth in concrete block of size 200mmx200mmx500mmcasted in PCC 1:3:6 type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surface, complete all as specified and as directed. 42 Road crossingby adopting trenchless tunneling work through specilised pipe jacking method by errecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any kindof soil including hard rock,inserting DWC HDPE casing pipe in any length, and necessary conveyance charges of machinery and other required materials in co-ordination with the concered authorites all as specified and as directed. Note: Quoted rate is deemed to be inclusive of all necessary tools/plant/machinery and obtaining necessary permissions to carryout the work. 43 Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc; metal flush boxes suitable modules as directed with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLSHunsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- 44 One light/fan/bellpoint controlled by one switch 45 One 3/5 pin socket outlet, 5 Amp on independent board 46 One socket outlet 3 Pin, 5 Amps, on the same board 47 One two way point controlled by one 2 way switch 48 One light point controlled by 2 way switches, 49 Point wiring for power point control by one switch with 2.5 Sqmm nominal area PVC insulated single core multi standard copper conductor FRLSH insulated and undheathed heavy duty cable in colour code including earth wire with cable of size 2.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed in PVC conduit of not less than 20mm dia and 1.5mm wall thickness (ISI marked) terminated into annealed steel terminal boxes including modular frame and cover plate for fixing of switches, sockets etc; complete all as specified and as directed. 50 Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia, medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly, complete all as specified and as directed.Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 51 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmmas earth continuity conductorconnected to commen earth dolly complete all as specified and directed.Note: - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 52 Sub main wiring with four run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including two run ofsingle core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed.Note: - Four run of 6 sqmm single core copper conductor cable and two run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 53 Sheet metal, VTPN distribution board (DB) fitted with DPX3, 160 MCCB, 04 way, (DPX3 -160 +12), complete with metal door, 415 volts rating and IP 56 protection the DB shall be fixed flush to wall and including all internal connection, necessary reducer lugs all as directed by Engr-in-Charge. 54 MCB, Single pole, 240 volt, 40 Amp, 10KA rating,C curve, complete with connection testing and commissioning, complete all specified and directed. 55 Deduction to be made from BOQfor Sch A Part -XIII (Schedule of credit) during AOC.Note: Tenderers shall not quote for this schedule.
Contract Date: May 23, 2026 Contract Value : 4.61 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Jammu And Kashmir View Result →
13.
Defence #11149786 AOC
Tender For Provision Of Deficient Smqs At Najafgarh Under Ge Af Tughlakabad - SCH A PART XI (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule A Part-II. 11 INTERNAL WATER SUPPLY 12 Supply and fixing Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia fixing in pipe with 1.25 meter long flexible tube and ABS wall hook including making connection and fixed to 15mm bore completeall as specified and directed. 13 Supply and fixingangle valve of cast coper alloy chromium plated fancy type screwed down high pressure with crutchor butterfly handle screwed both ends for iron pipe or for unions and fixed 15 mm bore (concealed) complete all as specified and directed. 14 Supply and fixing 15mm dia Two Way Bib taps, fancy type,,cast copper alloy chromium plated with crutch or butterfly handle, screwed down for CPVC pipe or for brass ferrule and fixed complete all as specified and as directed. 15 Supply and fixingBrass CP Mixer for mixing hot & cold water screwed down for 15 mm dia CPVC Pipe and fixed all as specified and as directed. 16 INTERNAL ELECTRIFICATION 17 Supply and fixing LED Lamp 9 watt 220 volts AC of suitable size complete all as specified and as directed. 18 Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 19 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 20 Supply and Fixing LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.complete all as specified and as directed. 21 Supply and fixingLED Building Securitylight fitting 25 watt complete all as specified and directed by Engr -in- charge. 22 Supply and fixingGI light gradepipe 1.5m long bend to 45 degree andof diameter 25 mm suitable to building security light power cord pipediameter with necessary clamps of for fixing building security light all as specified and directed including making hole to wall if necessary (For Bldg Security Light) complete all as specified and as directed. 23 Supply and fixing MCCB 63 Amps 4P 25 KA 415 Volt Make Indoasian Cat No 830020 includingMCCB Enclosure for 63 Amp MCCB Make Indoasian Cat No 811985 fixed on wooden board of appropriate size for mounting of enclosure complete all as specified and as directed.NOTE:-Rate inclusive of Fixing of cable including lugging complete (For06 Qtrs) 24 Supply and Fixing ceiling fan 230V, 50 Hz AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed. 25 Supply and Fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm (for Toilets) complete all as specified and as directed. 26 Supply and Fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m (for Kitchen) complete all as specified and as directed. 27 Supply and Fixing electric water heater, storage type steel body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate, NRV, connection piece etc. complete all as specified and as directed. 28 Supply and fixing Smart RF/CellularSingle Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 315 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Radio Frequency communication facilitywith self healing mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry including Polycarbonate Meter Box of minimum suitable size for 1 Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per prevalent IS . Including Taking down of existing meter and deposit to MES store yard for safe custody all as specified and as directed (For06 Qtrs)Note:- Contractor has to ensure integration and maintainance of the above 06 nos of meters withthe existing Advance Metering infrastructure (AMI) of smart meters of different makeswithout any additional infrastructure and cost implication. 29 EXTERNAL WATER SUPPLY 30 Material and Labour for valve chamber of internal size 750x750x750 mm comprising of 50 mm thick PCC 1:5:10 type E2 foundation, 200 mm thick brick wall in CM 1:6 ,15 mm thick plastring in CM 1:4 internally and externally up to 50 mm below GL, 100 mm thick PCC 1:3:6 type B1 as in coping, 3 mm thick MS sheet cover with suitable hinges and locking arrangements, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed. 31 EXTERNAL ELECTRIC SUPPLY 32 Supply and fixing of LED security/street light fitting 1x70 W LED 5700K energy saving and environmental friendly long life versatile pressure die cast aluminium hosing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LEDs as light source and electronic driver suitable for pole dia 40mm including 45mm dia light grade tube bracket, bent to shape, 1.8 mtr lenght with two Nos clamp of size 50mmx6mm with nuts,bolts,washers etc. including connection with 1.5 sqmm two single core PVC insulated and PVC sheathed cable stranded copper conductor upto ceiling rose and fixing on walls/pole complete all as specified and as directed. 33 Supply and fixingof LT Panel board outdoor type, double door, fabricated made of MS/CRCA sheet 3.15 mmm thick with MS angle frame of size 50x50x6 mm with locking arrangements cubical type feeder pillar box with 04 Nos legs including necessary PCC work with suitable size of PCC 1:3:6 including necessary insulators and 04 Nos of copper bus bar of size 30 mm x 5 mm capacity of 600 Amp with Air circuit breaker, provision of inlet and outlet cable glands and earth connection lead etc complete and connection of all incoming and outgoing cable using aluminium terminal sockets/lugs duly crimpled and necessary two coats of paint with approved make and colour and grade of first quality synthetic enamel paint over a coat of red oxide primer including necessary preparation of surfaces and the panel should be dust and vermin proof factory fabricated , CPRI approved totally enclosed free standing /wall mounting type suitable for 415 vots, 50 HZ 3 phase 4 wire system complete in all respect and confirming to latest relevant of ISI specifications including necessary connections, inter connections with copper conductor cable of required size including MS angle frame of size 50x50x6 mm structure at bottom and with including the following accessories.:- 34 INCOMING :- (i) MCCB,AC 415 Volts, adjustible thermal release, 4 pole current rating 63 Amps, breaking capacity 16 KA (ICS=ICU=ICW for 1 Sec) with fixed type overload protection,short circuit protection = 01 No.(ii) 4 strip copper bus bar of size 30 x 5 mm with specific colour (R,Y,B) insulation = 01 set(iii) Metering panel comprising,voltmeter and ammeter, digital type with selector switches CTs, control fused and indicating lamps. OUTGOING : (i) MCCB,AC 415 Volts, adjustible thermal release, 3 pole current rating 32 Amps, breaking capacity 16 KA (ICS=ICU=ICW for 1 Sec) with fixed type overload protection,short circuit protection = 02 Nos for (01 No Building & 01 No. spare) (ii)MCB SPN 32 amp 215 volts C curve (for street light) = 01 No.(iii) Digital Voltmeter 0-500 volts - 01 No.(iv) Digital Ammeter 04-400 Amps - 01 No. (v) Indicator lamps Red, Yellow & Blue.(vi) Complete wiring of Panel Board.(vii) CT ratio 400/5 Amps 35 Supply and fixing SMC junction box, pole mounted, 100% weather proof, fire retardant , complete with side hinged door of size 250x200x105 mm , made out of engineering plastic including 3 phase 4 wire aluminium bus bar of capacity 60 amp of required size complete with bus bar insulator fibre/ porcelain and one no single pole MCB SPN 6 Amp . B Curve and box fixed on pole with clamps made out from MS flat iron of size 25x5 mm with nute and bolts complete all as specified and as directed. 36 Material and Labour for sub main wiring with 2 run of 1.5 sqmm multistand copper conductor , PVC insulated, 1100 volts grade in and including PVC condut with 1.5 sqmm PVC insulated multistrand copper earth continuity conductor including lugs of suitable size from light fitting connector to looping box on pole complete all as specifed and directed. 37 AREA DRAINAGE 38 Material and labour for pre-cast perforated RCC drain cover with frame ( rectangular or square) the area of each cover should not be more than 0.5 square meter and thickness of 60 mm each with holes, manufactured with M-30 grade of concrete by vibro compacting process using accurately designed moulds and suitably reinforced to enable the covers to take load as specified i.e M-20 MT for heavy duty (When tested as per IS -12592) complete all as specified and as directed. 39 SEWAGE DISPOSAL 40 Supply, laying in trenches and jointing of 200 mm dia bore double wall corrugated polyethelene (HDPE) pipe of stiffness class designation SN8 including all necessary jointing material and fittings such as couplers, connectors,bends, elbows ,Tees and end caps etc complete all as specified and as directed
Contract Date: May 22, 2026 Contract Value : 1.91 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
14.
Power #11131078 Price Bid
Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , 11 Kv completion Poly. Disc Insulator 45 Kn , Stay Set 16X1800 , M.S. Angle 65X65x6 Mm , Acsr Dog Conductor , A.B.Cab. L.T. (3X120)+ (1X95)+(1X16) Sq.Mm , Earth Rod 2540X20 Mm , 11 Kv V-Type Steel Cross Arm 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , D.O Fuse Set 11 Kv , Acsr Weasel Conductor , Ms Channel 100X50 Mm , 11 Kv Tpmo , Lt Abc 3X50+1X35+1X16 Sq.Mm , G.I. Wire 6 Swg , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Abc (3X95+1X70+1X16)Sq.Mm , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 11 Kv Cable Box O/D 3X120 Xlpe , 11 Kv Cable H.T. Xlpe 3X120 Sq.Mm , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 11 Kv Cable Box O/D 3X185sq.Mm , Aluminium Cable 1X240 , 11 Kv Cable Box I/D 3X185sq.Mm , 11 Kv Tvm Category C , 11 Kv Ct/Pt Ctr 10/5Amp , 11 Kv Met. Cub. Pilfer Proof Ctr 10/5Amp , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv V-Type Steel Cross Arm 65X65x6 Mm , Ms Channel 100X50 Mm , 11 Kv Composite Polymer Pin Insulator , Lt Abc 3X50+1X35+1X16 Sq.Mm , Disc Fitting 45 Kn (T&C) , Abc (3X95+1X70+1X16)Sq.Mm , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 11 Kv Cable Box O/D 3X120 Xlpe , 11 Kv Cable Box O/D 3X185sq.Mm , Aluminium Cable 1X240 , 11 Kv Cable Box I/D 3X185sq.Mm , 11 Kv Tvm Category C , 11 Kv Ct/Pt Ctr 10/5Amp , 11 Kv Met. Cub. Pilfer Proof Ctr 10/5Amp , Erection Of 11 Mtr Double Pole Structure For 11 Kv Line Including Excavation Of Suitable Size Pits, Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulators With Pins, Disc Insulators With Complete Fittings, Etc., Strictly As Per Respo Drawings/Standard Norms; Providing And Fixing Of All Necessary Clamps Made Of M.S. Flat 50×6 Mm With Suitable Nuts & Bolts, Stone Pad, Jumpering, Alignment, Tightening And All Allied Works; The Scope Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Erection And Fixing Of Single Pole Structure For Lt Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Grouting Of St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:3:6 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Erection And Fixing Of 11 Kv D.O. Fuse Set On St/Pcc Pole Including Mounting/Fixing Materials, Clamps, Nuts & Bolts, And Accessories Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Fuse Set Shall Be Supplied By The Department; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Provided By Contractor As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Erection And Fixing Of 11 Kv Tpmo Set On St/Pcc Pole Including Mounting/Fixing Materials, Clamps, Nuts & Bolts, And Accessories Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Tpmo Set Shall Be Supplied By The Department; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Provided By Contractor As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying And Stringing Of Overhead 11 Kv Ht Xlpe Cable (3×120 Sq.Mm) On St/Pcc Poles, Including Proper Hanging And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site, And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying And Stringing Of Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Laying Of 140 Mm Dia (O/D) Pn-4, Pe-80 Grade, Uv Stabilized Hdpe Pipe In Standard Lengths (6 M Each) By Trenchless/Drilling Method For Laying Of Underground 11 Kv Cable, Complete In All Respects As Per Relevant Is Specifications And Directions Of The Site In-Charge; The Scope Of Work Includes Formation Of Entry And Exit Pits, Drilling With Suitable Machinery And Drilling Fluid, Alignment, Jointing, Insertion Of Pipe, Protection Of Existing Utilities, And Complete Site Restoration; The Work Also Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Materials, Safety Arrangements And All Allied Works Required For Proper Execution; The Contractor Shall Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×185 Sq.Mm Underground Through Hdpe Pipe, Including Pulling, Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , 11 Kv Ht Xlpe Cable Of Size 3×185 Sq.Mm , 11 Kv Ht Xlpe Cable Of Size 3×120 Sq.Mm , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 6 Swg , G.I. Wire 4Mm/ 8 Swg , Grouting & Fixing Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , F-Clamp , Holding Clamp With Nut Bolt , Dead & Clamp , Lt Clamp , X Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Insulators Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Lt Fuse Box Complete In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Lt Fuse Set Complete In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of J Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Weasel Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Installation Of Maintenance-Free, Multifaceted, Corrosion-Resistant Chemical Earthing Electrode Of Size 80 Mm Dia × 3000 Mm Length, Complete With 50 Kg Backfill Compound And All Required Accessories For Body/Neutral Earthing Of Transformers, Including Providing And Fixing Of M.S. Earth Strip For Connection (The Strip To Be Properly Welded To The Earthing Electrode And Neutral Support), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Excavation, Installation, Welding, Connection, Testing, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Jumpering Of Lt/Ht Lines For Proper Energization, Including Cutting, Dressing, Binding And Fixing Of Jumpers With Suitable Connectors/Clamps, Ensuring Proper Electrical Continuity And Safety, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
15.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
16.
Housing Urban and Rular Development #11076972 AOC
Tender For Supply Installation Testing And Commissioning Of Dg Set For Ct Scan Department Allied electrical installation Work At Islampur Sd Hospital, Islampur, Uttar Dinajpur.- 1 Supply & Delivery at site on foundation incl Testing & commissioning of 125 KVA, 415V, 50Hz, 3Ø silent new DG Set incl. full tank HSD oil,comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery,CPCB IV+ complient Engine & Acoustic Enclosure having following specifications :- ( Conformance Standards -IS/IEC 60034-1,ISO 8528, ISO 3046, ISO 9001,) 2 Make: KOEL GREEN / Jackson - Cummins / Eicher / Mahindra / Catterpillar / Volvo penta 3 Engine Type: 4 stroke Diesel EngineRPM: 1500BHP: 156 or higherCanopy size (height w/o silencer ) in mm - 3950 x 1350 x 1425 or higherBore x Stroke: 107 mm x 124mmDuty: PRIMECooling: Liquid cooled with radiatorCylinder: 4 / 6 in lineCurrent - 174 amp 4 Aspiration: Turbo ChargedGovernor Type: ElectronicFuel Tank Capacity: 250 Ltrs or higherFuel consumption at 75% rated load with radiator or fan: 22 L/Hr or lessFuel consumption at 100% rated load with radiator or fan: 30 L/Hr or lessOverload Capacity: 10% over load for one hour for every 12 hours continuous running at full load or better. 5 Engine instrument Panel: Consisting of starting switch with key, Lube oil indicator, water temperature Indicator, RPM Indicator and Hour meter. 6 Safety Controls: Emergency Stop,Low lube oil pressure warning/shutdown, High engine water temp warning/ shutdown, sensor failure indicator, engine overspeed indicator, battery charging and low battery indicator. 7 Exhaust Silencer :Residential TypeExhaust pipe size- 4 inchExhaust temp- 488 °celsiusStarting System : 12V / 24V Starting system complete with starter motor, charging alternator with rectifier and cutout as per manufacturer standard. 8 Battery : Lead Acid, Low maintenance or SMF and confirming to relevant IS Specifications with LOW/HIGH Battery voltage and weak battery warning. 9 Alternator Make Koel Green /Stamford / Leroy somer / CG / Mahindra / GE 10 Rating: 415V, 3PH, 50Hz, 125 kVA, 1500 RPM having double layer stator winding & dynamically balanced RotorType : Brushless, self excited and self regulatedInsulation : Class HProtection: Screen Protected drip proof with min IP-23 Protection.RPM : 1500Voltage regulation:± 0.5%Winding Connection: Star with NeutralTotal Distortion factor: Less than 3%Total Harmonic distortion in O/P waveform: Less than 5% 11 AMF Panel ( CPRI APPROVED) :- 12 Cubical type floor mounted AMF Panel made from 14 SWG Sheet Steel, dust and vermin proof with locking features, duly pretreated, powder coated painted and aesthetically finish, suitable for controlling of 125 KVA DG set having following specifications:i) 200A AC 1 duty, FP power contactor and U/V release etc. - 2 Nos (Make: Legrand/Siemens /Schneider/ABB/L&T).ii) 200A, TP MCCB (Breaking Capacity: 50KA) with microprocessor based LSIG Protection.(Make: Legrand/Siemens /Schneider/ABB/L&T).iii) By-pass Changeover Switch of rated capacity.iv) On-delay timer for load change-over .v)Off-delay timer for engine shut offvi) Push button type engine ON/OFF Switch 13 vii) Battery Charger complete set with voltage regulator, booster selector switch, ON/OFF switch, voltmeter and ammeter for charging the battery from mains in addition to the battery charging alternator mentioned above.viii) Indicating Lamps: 05 No.s each indicating Mains ON, Load on Mains, Set Running, Load on Set and Battery Charger ON respectively.ix) A/V alarm for low lubricating oil pressure, high water temperature, start failure and DG over load.x) Mode Selector Switch for setting on AUTO/MANUAL/TEST.xi) Microprocessor based relay with composite meter for digital display of the following: 14 Generator Voltage/AC Mains VoltageGenerator current in all phasesFrequency and PF & EnergyIndication for alternator supplyRunning time indication : number of hours of operation, and service intervals and service due indications.The AMF Panel must be so designed to ensure trouble free performance and ensure switching over eklectrical load to DG within 15 Sec from the instant of mains failure. 15 Acoustic Enclosure: The DG Set should have integrated high quality acoustic enclosure at the manufacturing state itself as per CPCB-IV norms.Base frame : Common Iron channel fabricated base frame containing the engine and alternator mounted on AVM pads and having provision for lifting hook. 16 Terms & Conditions :- 17 (i) All materials, equipments & accessories must conform to relevant IS specifications. The DG Set to be supplied must be from the authorizedOEM of the respective Engine Manufacturer. 18 (ii)Necessary manufacturers test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment. 19 (iii) Copy of Type Approval Certificate and Certificate of COP must be produced at the time of delivery issued from competent Authority (As per CPCB Norms). 20 (iv) Circuit Diagram for AMF Panel must be submitted from the Manufacturer/ OEM. 21 (v) The entire set must be warranted at least 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier.However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier. 22 Supply of HSD Oil. 23 Supply of Lubricating Oil. 24 S & F exhaust pipe of 100 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set to nearest building (Horizontal Run) with suitable high temperature painting ( from DG sets to top of the building plus 3mtr or as per CPCB) for 125 KVA DG set as per direction of EIC. 25 S&F exhaust pipe of 150 mm. black pipe (thickness 4 mm.) including S&F flange, nuts, bolts & washers etc. as required from the nearest building wall to top of the building roof. (Vertical run) with suitable high temperature painting. 26 Making insulation by 2 glass wool including netting arrangement and covered with aluminium clading as per direction of the EIC. 27 a) 100 mm. dia exhaust pipe. 28 b) 150 mm dia exhaust pipe 29 c) Residential type silenser pipe 30 S & Erection of special type supporting arrangement for Exhaust pipe line with necessary foundation work as required as per site condition incl. S & F special type MS angle iron bracket/flat of required size as per OEM design with necessary nuts, bolts, welding arrangement etc. as required for the above exhahaust piping arrangement 31 S&F rain protection canopy made of GI sheet of 16 SWG. 32 S& delivery of 200 ltrs. Capacity heavy gauge MS sheet barrel. 33 Supply & delivery of best quality oil hand pump with 1 dia PVC flexible pipe (12 ft. approx.) 34 Supplying and fixing 415V, 250A,TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc.[D-2/3(a)] 35 Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required - 80mm dia 36 32 mm dia( for control cable) 37 Supply & Delivery of4 Core 120sqmm XLPEInsulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / RR /KEI/ Havells as approved by E.I.C] 38 Laying of one No. cable above 35 sqmm andupto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.[F-2/1(b)] 39 Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MSclams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting 40 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below : 41 4Core 120 Sqmm. [F-4, 7/a] 42 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 43 4Core 120 Sqmm.[F-4, 7/a] 44 Supply & laying of 1.1 KV grade 12 core 2.5 sq.mm. PVC copper conductor control cable partly recessed and partly by shaddle on wall to interconnect DG set with AMF panel. 45 Supply & laying 1 x 50 sq. mm. single core flexible Al Armoured Cable in suitable size PVC pipe (reinforced) on wall / floor from neutral earth bus to DG set neutral point including both side socketing. 46 Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil)[G-1/1(a)] 47 Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts.long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts(PWD-G1/2(d)) 48 Earthing with 50 mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. --- By ISI-Midium G.I Pipe 49 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall includingproviding drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required.[G-2/4(c)] 50 Extra connecting the neutral of DG to earth electrode including S&F 50mmx6mm Galvanized(Hot Dip) steel strip on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape. 51 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe [G-2/3(a)] 52 Extra for treatment of soil by using salt & charcoal or coke for plate electrode. 53 Supply & fixing black PVC heat shrink sleeve for covering the 50 x 6 mm. GI flat. 54 Commissioning & testing of the Diesel Generator Set along with AMF panel with agencys own tools & tackles in presence of EIC. 55 Cutting RCC floor by special tools & tackles very carefully without any damaging and removing the shifted rubbish & levelling up and restoring the surface for 8 nos. earth-pit as per direction of EIC. 56 Supplying and fixing 4 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection with 01 nos 415 V, 63A Four Pole MCB Isolator as incomer and 12 nos 240V, 16A-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail ofDBs and necessary connection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to G.S. (Make: Seimens / ABB / L & T / Legrand)[D10/14, D5/6, D6/7] 57 Supply & Fixing, 250 V, 6-10A per way, 2+10 way SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as Incoming & SPMCBs (C Curve, 10kA) as Outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire & Neutrallink & provision for earth attach for Enclosure (607712), 1 no 40A DP Isolator as Incoming, 10 nos 6-10A SPMCB as outgoing (Make: Seimens / ABB / L & T / Legrand) 58 Supply & Delivery of4 Core x 35sqmm XLPEInsulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / RR /KEI/ Havells as approved by E.I.C] 59 Laying of cable from 3½ core 35 sqmm and upto 3½ core 50 sqmm on wall/surface including S & F MSclams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting 60 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below : 61 4Core 35 Sqmm. [F-4, 7/a] 62 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 63 4Core 35 Sqmm.[F-4, 7/a] 64 Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required 65 2x84/0.3(6sqmm)+1x56/0.3(4sqmm) ECC. [E14:1(a)iv] 66 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 67 6sq mm.[F5:9(iii)] 68 4sq mm [F5:9(ii)] 69 Distn.wiringin 22/0.3 (1.5 sqmm) singlecorestrandedFR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall andceling portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixedon sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC.avg run 9mtr[for substation wiring][E-10/3a(iv)] 70 Supply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. safety wire , P2 capacitor and all accessories. (Make- Crompton / Usha / Orient/ Polar) [BEE star rated] -- Sweep Size- 1200 mm (48), Wattage ≤ 55 Watt, R.PM ≤ 350, Air Delivery ≥ 220 C.M.M 71 Fixing the above ceiling fan as per GS ( C-3/21a) 72 Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.[E-10/3a(iv)] 73 Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [BEE star rated]300 mm (12), 4 Blade, RPM ≤ 1420 , Wattage ≤ 82 Watt, Sound level ≤ 56 dB, Air Displacement (In CFM) ≥ 1120 74 Fixing only 12 inch exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust 75 Supply & Fixing Al louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) -- 30 cm Exhaust fan (12) 76 Supply and Delivery of 4 feet Industrial box typesingle LED tube fitting incl. Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 77 Fixing only single/twin fluorescent light fitting suspended 25 cm below the ceilingwith 2 No. 20 mm dia EI conduit (14 SWG) supportsfixed with “U” type MS clamp whose both side fixed on ceiling with sutable size 4 nos. fastenerand other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “U” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 78 Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Contract Date: May 12, 2026 Contract Value : 20.92 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
17.
Health and Family Welfare #11073758 Technical Bid
Tender For Major Works At Girls Ashram Hostel Merpur Kotda Udaipur- 1 Dismantling Doors, Windows And Clearatory Windws Steel Or Wood Shutter Including Chowkhats And Holdfasts Etc. 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead: For Thickness Of Tiles 10Mm To 25Mm. 3 Dismantling Gi Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes And Including Stacking Of Pipes Within 50 Meter Lead: 4 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. 5 Grading Roof For Water Proofing Treatment With Water Proffing Compound. Cement Mortar 1:4 (1Cement : 4 Coarse Sand) 6 Providing & Laying Broken Glazed Titles On Roof ( Broken Glazed Tiles Not Less Than 9 Kg/Sqm) On Top Of Hot Bitumen @ 1.7 Kg/Sqm. (1.40 Kg Of Vg-40 (30/40 )Grade And 0.30 Kg/Sqm. Of Vg-10 (80/100) Grade) And Joints Filled With Cement Mortar 1 :2 (1 Cement:2 Marble Dust Mixed With Water Proofing Compund All Complete As Per Direction Of Engineer-In-Charge. 7 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) 8 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) 9 Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete.New Plastered Surface (Three Or More Coats) 10 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 11 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm 12 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete 13 Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Sqm Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3Mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge 14 Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). 15 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10Cm Long Embedded In Cement Concrete Blocks 15X10X10 Cm Of 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Require Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 16 Providing And Fixing M.S. Sheet 1Mm Thick Dabble Leaf Door Shutter In Angle Iron Frame 35X35X5Mm Suitabilly Diagonally Braced With 25X3Mm Flat Iron Above And Below Lock Rail Of Size 50X5Mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint Add Extra For Double Leaf Shutters. 17 Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3Mm With Suitable Screw At Not Exceeding 150Mm Distance. 18 Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. 19 Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged : Aldrop Of Mild Steel 12\ Long X12Mm Dia 20 Steel Hinges For Wooden Chowkhat 4\ Size. 21 Steel Handle 6\ Size 22 Labour Charges For Repair To Door / Window Without Using Any Material Such As Applying Randha (Finishing) Tightening Of Bolts & Screw Etc. 23 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 24 Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated „J‟ Or „L‟ Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified. 3.0Mm Thick (Wt. 5.0 Kg./Mtr. Sq.) 25 Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: 26 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 27 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 28 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture : 29 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 30 Providing And Laying Ceramic Mat Floor Tiles (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown Of Any Size, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 31 P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440Mm. 32 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) 15 Mm Nominal Size 33 20Mm Nominal Size 34 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings, This Included Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement , Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.(External Work).15 Mm Nominal Size 35 20Mm Nominal Size 36 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 75 Mm Dia 37 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 38 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia 39 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Coupler (Socket) 160 Mm Dia 40 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Plain Tee 160 Mm Dia 41 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Tee 110Mm Dia. 42 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 110Mm Dia. 43 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 160Mm Dia. 44 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 110Mm Dia. 45 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 160 Mm Dia. 46 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Bend (Top Side) 110Mm Dia. 47 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 110Mm Dia. 48 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 160Mm Dia. 49 P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design. 1000 Litres Capacity. 50 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 15Mm Nominal Bore. 51 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 25Mm Nominal Bore. 52 Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick C.C Bed Of 1:5:10, M-15 Grade C.C Floor & Rcc Slab Covering With M15 Grade C.C. Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140X150 Cm.(For 50 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect 53 Size 230 X110 X150 Cm.(For 20 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. 54 P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall :Size 550 Mm X 400 Mm 55 P & F Looking Mirrors With P.V.C. Frame Of Approved Make As Per Direction Of Engineer-In-Charge Size 500X400Mm 56 P & F Grating Of Approved Quality/Make:Stainless Steel Sheet Size 125Mm Dia. 57 P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: Brass 400 Gm,15Mm Nominal Bore. 58 Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade C.C. Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead.Depth Up To 0.5 M 59 Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick C.C. 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.-Do- Size 450 X 450Mm Depth Upto 0.5 M Cement Cover With Frame 60 Construction Of Soakage Well In All Type Of Soil With 300 Mm Thick Dry Masonry, Top And Bottom 300 Mm Course In Cm 1:6, 80Mm Thick Stone Slab, Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.C Flooring , Earthwork Complete As Per Approved Drawing Including Disposal Of Earth Within A Lead Of 50 Mtr.: Size 300 Cm. Dia Outside & 300 Cm. Depth . 61 P & F Flush Cock / Flush Valve (Is : 9758 Mark) For Wc Of Approved Quality Make : (-Do-) Half-Turn Exposed 25Mm Nominal Bore. 62 P& F Waste Coulping With Fittings Of Approved Quality /Make: C.P Brass 32 Mm Dia 63 P& F Waste Pipe With All Fitting G.I(B Class) 32Mm 64 Construction Of Open Drain With 112Mm Thick Brick Masonry In Cm 1:4 Semi Circular S.W. Glazed Channel (Confirming To Is Standards) Fixed With Cement Mortar 1:1 Over A Bed Of 100Mm Thick C.C. 1:5:10, Filling Of Edged With M-15 Grade C.C. Flooring, 12Mm Cement Plaster 1:4, Over All Exposed Faces, Excavation & Disposal Of Earth With In A Lead Of 50 Mtr Complete As Per Approved Drawings : 150 Mm Drain,225Mm Av. Depth Width 15 Cm S.W. Glazed Channel. 65 Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 150Mm 66 Supply Of Erw M.S. Black Casing Pipe Isi Marked (Is:4270/1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 150 Mm Nominal Bore Of Pipe 67 S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size: 150Mm Dia 68 S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. 69 Providing & Fixing Of Hdpe Pipe Confirming To Is:4984:2021 For Water Supply Suitable For Submersible & Jet Pump With Required Fittings Ie Socket, Elbows, Tee Etc. Complete In All Respect. For Vertical Installation 63 Mm Od 6 Kg / Cm2 70 For Horizontal Installation 63 Mm Od 4 Kg/ Cm2 71 Sitc Of Radial / Mixed Flow Water And Anti-Corrosive Liquid Filled Submersible Motor Pump Sets Suitable For 100/150Mm Dia Borewell. The Size Of Adopter Fixed On Top Of The Motor Should Exceed The Top Of Coupler , For Safegaurd The Coupler. The Job Includes Labour Part Of Lowering Of Riser Pipe G.I./ H.D.P.E. With Rope, Cables & Pump, Installation Of Complete Fitting And Accessories, Jointing Of Electrical Cables Up To Starter. All Labour For Testing Of Submersible Pumps Set And Supply Of Water To Water Mains, Complete In All Respect. 100 Mm Diameter Submersible Pump Shall Have Following Hp Rating, Phase, Head Range, Discharge Range Respectively. 3.0 Hp, 1-Ø, (40 -170)Mtr, (60- 20) Lpm Copper Wound 72 Sitc Of Ip 54 Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Coordination Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection(For Three Phase Pumps), Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps, 2P/4P Mcb Etc. Suitable For Following Rating Motors Complete In All Respect. For Three Phase Submersible / Mono Block Pump 3.0 Hp To 5.0 Hp ( Dol Starter ) 73 Providing & Laying Of Polypropylene Rope Confirming To Is:5175 For Submersible Pump Of Following Sizes. Complete In All Respect. 20Mm (Suitable For 90 Mm Od Pipe) 74 Supply And Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. 10.0 Sq.Mm 3 Core Flat / Round 75 Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Short Point (Up To 3 Mtr.) 76 Medium Point (Up To 6 Mtr.) 77 Long Point (Up To 10 Mtr..) 78 Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr On Board 79 Medium Point (Up To 6 Mtr.) 80 Long Point (Up To 10 Mtr..) 81 Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 82 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Blanking Plate 83 Modular Mcb 6 A To 32 A Dp (Is:8832 Marked) 84 Providing & Fixing Of Modular Type 100W Step Fan Regulator Duly Isi Marked (Is 11037) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Virgin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including Making Connections, Testing Etc As Required. 5 Step Fan Regulator 2 Module 85 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 1 X 1.5 Sq.Mm 86 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 87 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm 88 2 X 6.0 Sq. Mm. + 1 X 2.5 Sq. Mm 89 4 X 10.0 Sq.Mm 90 4 X 6.0 Sq.Mm 91 1 X 16.0 Sq.Mm 92 1X 4.0 Sq.Mm. 93 Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Glazed Door (Three Phase) Ik-09 And Ip-43 With Metal End Box 6 Way 94 Glazed Door (Single Phase) Ik-09 And Ip-43 With Metal End Box 12 Way (12+2) 95 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating 96 Double Pole Mcb(With B/C Curve Tripping Characteristics) 40 A Rating 97 Four Pole Mcb(With B/C Curve Tripping Characteristics) 50/63 A Rating 98 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners Etc. As Required. 32 Mm X 12 Mm 99 Making Of Hole In Wall (Brick/Stone) Of Required And Placing Np-2 Rcc Pipe Ring Of Required Size For Housing Exhaust Fan And Making Good The Same, With Cement Plaster Required Of Following Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Up To 457 Mm Size 100 P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 101 Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wound Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 300 Mm Sweep(900/1400 Rpm) 102 P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Required. Up To 380 Mm Size 103 Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminium Housing With In Built Driver , System Lumen Efficacy ≥ 110 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1170Mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm 104 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Surface Mounting (With Extruded Alumn. Housing ) Minimum Lumen Output 1600 Lm 105 Minimum Lumen Output 1950 Lm 106 Sitc Of Ip20, 1X1 Led Surface/ Recessed Mounting Backlit & Smd Mid Power Type Led Light Fixture Not Less Than 35 Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution.Operating Voltage Range 140-285 V, Hv Cutoff - Lv Cutoff Should Be 300-100V High Efficiency With 4 Kv Internal Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. Surface Moutning Minimum Lumen Output 3600 Lm 107 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 108 Providing & Fixing Of Extra Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Including Cutting, Threading, Drilling, Fixing Quarter Pin Etc As Required. 109 Providing & Fixing Of 450 Mm Sweep Oscillating Type Wall Mounting / Pedestal Type Fans With Three Speed, On And Off Position, Sintered Iron Bush Oil Impregnated, With Metal Front And Back 120 Or More Ribs Guard; Three No. Aluminium Blades, Minimum Air Delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./Min/Watt, Noise Level Should Be 110 Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core 1.5 Sq.Mm Copper Conductor ,Making Connections, Testing Etc. As Required. 300 Mm Sweep 111 Supply And Installation Of High Tensile Low Carbon Steel Rod Molecularly Bonded With 99.9 % Copper Thickness (250 Microns) And Confirming To Ul 467, Is/Iec 62561-2 Of Following Size And Length And As Per Point Mentioned (A), (B), [C), (D), (E) Below :- (A) Bore A Hole Of Dia. 100 Mm Of Required Length, Place The Rod In The Centre Of Hole (B) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri/ Erda Tested With Rms Capacity Of Minimum 30 Ka For Withstanding 1 Second .To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043-1987,Ieee 80-2013 (Clause 14.5D) , Ieee 837 & Ier 1956 With Latest Amendemnts © Connect The Rod With Copper Strip/Conductor/Wire With Suitable Clamp Made From Tinned Copper And Ss 304 Bolt (D) Place Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. (D) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. (E) Test Certificates For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 17.2 Mm Thick And 3 Mtr. Long 112 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. 8 Swg Copper Wire 113 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led/ Integrated Lens Diffuser & Should Be High Power Led Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Integrated Metal Case Potted Driver & Has A Unique Bis R Number ( As Per Is 15885) With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac & Low Voltage Cutoff @>=90 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs As Required. Led Street Light Fixture With Minimum Lumen Output 2500 Lm 114 Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. 32 Mm Dia. 115 Supply & Fixing Of Dry Powder Agent (As Per Is 4308:2019), Abc Type Fire Extinguisher (Stored Pressure Type) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test (For Cylinder Body) Certificate From Oem / External Nabl Accrediated Lab Is To Be Submitted. 6 Kg 116 Sitc Of Ro Water System With Filteration Stages = Particilate Filter- Membrane Life Enhancer Filter- Sediment Filter- Pre Carbon Filter- Ro Membrane Filter- Post Carbon Filter. Input Power Rating -230V Ac, 50Hz, Percentage Of Rejection Tds-90% Or Better, Having Following Features (A) Double Purification By Ro With Ess Or Latest Technology With Tds Indicator. (B) Spin Welded Ro Membrane Housing To Prevent Tempering. (C) Push Fit Component For Leak Proof Performance. (D) Fully Automatic Operation With Auto Start And Auto Off. (E) Ss/Abs Construction For Corrosion Free Lifespan. (F) Equally Suitable For Water From All Borewells, Overhead Storage Tanks, Water Tankers And Even Municipal Taps. (G) Ro Membrane Flushing - Auto Flush@ Every Start, Every Stop And Every One Hour Of Working For One Minute, Complete In All Respect With Following Capacity. Purification Capacity - 50Lph, Duty Cycle 270-500 Liters/Day 117 Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs 118 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 119 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 120 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size). 121 Kerb Stones Of 1200X300X150, 1000X450X150, 1000X600X150, 600X300X150 Size (M-30) Providing And Laying Cement Concrete Kerb Stones Of Different Sizes In M-30 Grade (Manufactured With Fully Mechanised Dry Cast Process With Forced Action Mixer Whose Arms Revolve Along The Main Axis And Rotate About Its Own Axis Also, Having Humidity Sensor For Moisture Control Of W/C Ratio In Concrete Mix. Manufactured With Steel Moulds (Milled And Manufactured In Csi Diamond Or Csi Nitro Process For Accuracy) On Steel Base Plate Of Min 16 Mm Thick; Having Vibration And Pressing Action Both Together With The Help Of Multiple Synchronised Vibrators. Power Of Hydraulic Station Should Be Minimum 50Kw For Compaction And Cured In Controlled Chambers Having Humidity Control And Automated Air Circulation System) In Position To The Required Line, Level And Curvature Jointed With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Making Of Joints, Drainage Opening Wherever Required. 122 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 123 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 124 Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 125 Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix 126 Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix 127 Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. 128 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. 129 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) 130 Random Rubble Stone Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Five Level Above 30Cm. Thick Walls In : Cement Mortar 1:6 ( 1-Cement : 6-Sand). 131 Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 25 Mm Thick. 132 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 133 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 134 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 135 Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size).
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
18.
Rural Development #11035862 AOC
Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Kuruli Tal Khed Dist Pune- Supplying and erecting modulartype switch6A / 10A 2 Supplying and erecting Street light bracket for erection ofSingle fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length 3 Providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16-3-2) 4 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.OH-PL/STP 5 Supplying and erecting Street light bracket made from 25mm. dia ‘B’class G.I. Pipe, 0.6m. in 6 Supplying and erectingLED street light fitting suitable for 36w TO 40w LED Street Light, including lamp, with PF > 0.95 class IP 65 . 7 Supplying and erecting LED street light fitting suitable for 50W lamp, including lamp, with PF > 0.95 class IP 65. 8 Supplying and erecting LED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65. 9 Supplying and erectingLED street light fitting suitable for 90 w LED Street Light, including lamp, with PF > 0.95 class IP 65. 10 Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 11 Supplying and erecting LED Flood light fitting of 150W, including lamp, with PF > 0.95,class IP 65 12 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 13 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 14 Labour Chrages for LED fitting on Street light or MS light pole. 15 Dismentaling Charges -LED street light of pole. 16 1.25 mm CRCA sheet metal enclosures box for Timmer and MCB 17 Supplying PVC insulated PVC round sheathed 1.5 sq.mm 18 Supplying & Laying armoured cable 4C X 6 Sq.mm. 19 Supplying & Laying armoured cable 4C X10 sq mm 20 Supplying & Layingarmoured cable 2C X 10 sq mm 21 Supplying & Layingarmoured cable 2C X 6 sq mm 22 Supplying & Layingarmoured cable 4C X 16 sq mm 23 Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) 5-3-3 24 Supplying, erecting & marking DPMCB 6 A to 32 A Bseries (for lighting) 5-3-7 25 Supplying and erecting Programmable Digital AlmanacTimer Microcontroller based with real time clock to operate on derived switching “ON” & switching “OFF” street light as per daily sunset and sunrise respectively 26 Supplying & erecting crimping type Aluminium lugs for cable upto 16 sq mm complete 27 Supplying & erecting crimping type Coper lugs for cable upto 1.5 To 6sq mm complete… 28 Supplying and erecting two pole power contactor 250V 32A for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3 29 Supplying & erecting mains with2x1.5 sq.mm F.R copperPVC insulated wire laid in provided conduit/trunking/inside pole. 30 Supplying and erecting mains with ISI mark WP2 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire No. 8 SWG 1-4-3 31 Supplying and erecting mains with ISI mark WP2 x 2.5 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 32 Supplying and erecting mains with ISI mark WP2 x 10.00 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 33 25 Amp, 32 Amp Three Phase L/T Contactor 34 2.5 Sq. mm Multistand Copper Wire 35 Insulation Tape 36 Water Proof Tape 37 Street Light Pole Box FRP 38 Cement Street Light Pole Clamp 39 M.S. Street Light Pole Clamp 40 LED Street light Arm bend pipe 41 Small Size FRP box for MCB 42 Big Size FRP box for MCB 43 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 44 Servicing And Primary Maintenance For Street Light Pole. 45 Light Poles painting in Silver Colour 46 26W LED Light To 100W LED Light Repairing 47 Old Pole Shifting, Rework and Foundation Work per Pole etc. 48 Supply &Fixing of Shakle Hardware with Nut Bolt 49 Supply and Installation of Mini Feeder Pillar with Stand 50 RCC Road Cheasling Charges with Tractor Breaker (1 Hours) 51 Tree Triming for Overhead Line 52 Tree Triming for Overhead Line 53 7-1-33 Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor 54 7-1-31 Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm aluminium conductor 55 7-1-34Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm aluminium conductor 56 7-1-35 Supplying, erecting & terminating XLPE armoured cable 4 core 120 sq. mm aluminium conductor 57 5-3-5 Supplying, erecting & marking SPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 58 5-3-9 Supplying, erecting & marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 59 5-3-29Supplying, fixing and commissioning MCB type change over switch 2 pole, 63 A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS 60 5-3-32 Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS 61 7-9-4 Supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. CB-CL/CU 62 7-9-5 Supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. CB-CL/CU 63 7-9-7 Supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. CB-CL/CU 64 4-4-5 Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. 65 Cable Joint Kit for armoured cable 20 upto 120Sq. MM Cable 66 GI Tar for service wire support with bobine. 67 Kit kat Type fuse 16A 32A 63A 120A 68 Taparia Tester 69 Spaner Set 70 Control Panel HRC Fuse 71 Supplying And Erecting Transformer Fidder Piller 72 5-2-19 Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation. 73 Bag filtter for 250/500/1000 LPH RO plant 74 Small cartridge filter 75 Big size cartridge filter 76 Coin mechanisum unit 77 Aster RO ATM unit 78 MECH-101 RO membrane cleaning chemical liquit -5 ltr 79 Supplying and erecting MS Pole Bracket 1100mm long (65-65-6) 80 Supplying and erecting aluminium standed cunductors 7/3.10 mm (Ant.) 145 Kg/Km) 81 Supplying and erecting ACSR aluminium standed cunductors 6/1-2.59mm Kg/Km 82 Supplying and erecting GI stay set for Pole including loops insulators height with achor plate 300x300x6 mm GI Wire 7/8 SWG 83 Supplying and erecting RSJ (Girder) Pole 125 x 70 mm (13.3Kg/m) 84 Supplying and erecting shackle type LT medium insulator 75x115 mm dia. With GI streep Nut Bolts etc 85 Supplying and erecting aluminium bobbin With GI streep Nut Bolts etc 86 Providing earthing with galvanized iron earth palte 60 x 60 x 0.6 cm with all materials 87 sand and Carban
Contract Date: Jul 28, 2025 Contract Value : 2.52 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
19.
Housing Urban and Rular Development #11031235 Technical Bid
Tender For Miscellaneous Civil Works For Lube Modernization And Bottom Upgradation (Lmbu) Project-Sl. No. Item No Description Qty Uom Rate Amount 134 01Gc.7.7 Supply Of All Materials And Construction Of Dry Lean Cement Concrete Sub-Base (7 Days Compressive Strength Of 10.0 Mpa) With 26.5Mm And Down Size Aggregate Including Cement , Water, And Approved Additives On A Prepared Sub-Grade, Mixed In Batching Plant, Transported To Site, For All Leads & Lifts, Laid, Compacted, Finished And Cured Etc. Complete As Per Irc:Sp:49 (Guidelines For The Use Of Dry Lean Concrete As Sub-Base), Drawings, Standards, Specifications And Directions Of Engineer-In-Charge. 300 M³ 5072 1521600 135 01Gc.7.11 Providing Joints In Pavements And Around Foundations As Per Standard/ Drawing Including Cleaning The Joints Of All Loose Materials And Sealing With Polysulphide Base Joint Sealant Of Approved Make Conforming To Bs:5212, Including Applying 2 Coats Of Approved Primer Compatible With The Brand Of Polysulphide Etc. Complete As Per Drawings, Specifications And Directions Of Engineer-In- Charge For. 136 01Gc.7.11.1 Construction Joints 20Mm Wide X 25Mm Deep. 10 M 200 2000 137 01Gc.7.11.2 Sealing Joint Around Pedestal And Column Etc. 20Mm Wide X 200 Mm Deep Including Filling With 20Mm Thick Impregnated Fire Board For The Full Depth Of Slab Except For 25Mm Depth From Top And Sealing The Top 25Mm With Polysulphide Base Joint Sealant Of Approved Make Conforming To Bs:5212, Including Applying 2 Coats Of Approved Primer Compatible With The Brand Of Polysulphide Etc. Complete As Per Drawings, Specifications And Directions Of Engineer-In- Charge. 60 M 320 19200 138 01Gc.7.11.6 Sealing Joint Around Precast Cover Etc. 10Mm Wide And For Full Depth Of Slab (Upto And Inclusive Of 300 Mm) Including Filling With Clean Sand For The Full Depth Of Slab Except For 10Mm Depth From Top And Sealing The Top 10Mm With Polysulphide Base Joint Sealant Of Approved Make Conforming To Bs:5212, Including Applying 2 Coats Of Approved Primer Compatible With The Brand Of Polysulphide Etc. Complete As Per Drawings, Specifications And Directions Of Engineer-In-Charge For. 100 M 540 54000 139 01Gc.8 Flexible Pavements Wearing Course And Miscellaneous Road Works 140 01Gc.8.4 Providing And Laying 30Mm Thick Bituminous Concrete As Per Section 507 Of Morth Specification Of Road & Bridge Works Including Design Mix, Trials, Heating Bitumen, Mixing Aggregates, Grit, Laying To Proper Grade And Camper Including Preparation Of Surface, Filling Pot Holes, Rolling To Proper Grade And Camber, Finishing And Clearing Of Surfaces, Spraying Tack Coat Of Bitumen, Etc. Complete All As Per Drawings, Specifications And Directions Of Engineer- In-Charge For Following Bitumen Grade:- 141 01Gc.8.4.3 Vg-30 500 M² 530 265000 142 01Gc.8.8 Providing And Laying Of Dense Bituminous Macadam Of The Of 60Mm Compacted Thickness As Per Section 505 Of Morth Specification Of Road & Bridge Works, Including Supply Of All Material, Preparation Of Underlying Course, Application Of Prime Coat Over Underlying Non Bituminous Coarse, Preparation Of Premix, Spreading, Rolling Etc. Complete As Per Drawings, Specifications And Directions Of Engineer -In-Charge. 500 M² 670 335000 143 01Gc.9 Rcc Pipe Culverts & Electrical Road Crossings Etc. 144 01Gc.9.1 Supplying And Laying In Position Rcc Pipes With Collars Conforming To Is:458 For Pipe Culverts, Cable Crossings Etc. Including Cutting The Pipe If Necessary, Lowering, Laying In Position To Proper Levels, Slopes Etc. Caulking The Joints With Spun Yarn Soaked In Neat Cement Slurry And Finishing With Cement Mortar 1:2 (1 Cement : 2 Sand) Curing Etc. All Complete As Per Drawings, Specifications And Directions Of Engineer-In-Charge. For Following Class And Internal Pipe Dia (Mm) Page 20 Of 27 Sl. No. Item No Description Qty Uom Rate Amount 145 01Gc.9.1.1V4 Pipe Class Np3 Internal Pipe Dia. 500 Mm 150 M 2800 420000 146 01Gc.9.2 Supplying And Laying In Position Pvc Pipes Conforming To Is:4985 Class - I For Cable Crossings, Including Cutting The Pipe If Necessary, Lowering, Laying In Position To Proper Levels, Slopes ,Providing Proper Jointing As Per Code Requirements Or Manufacturers Recommendations, Sealing The Open Ends Of Pipes With Removable Type Pvc Cap (Sealing Cap Will Be Paid Separately Under Relevant Items)Etc. All Complete As Per Drawings, Specifications And Directions Of Engineer-In-Charge. For Following Nominal Outside Pipe Dia (Mm) 147 01Gc.9.2.1V3 Pipe Class 1 Nominal Outside Pipe Dia. 160 Mm 150 M 650 97500 148 01Gc.9.3 Supplying And Fixing In The Encasement Concrete, Cable Crossing Indicator, Made Out Of 6Mm Thick Ms Circular Of Dia. 150Mm Welded To 16Mm Dia. Ms Rod Of Approximately 1.0M Length, Painted With 2 Coats Of Approved Enamel Paint Over A Coat Of Red Oxide Primer Etc. Complete. (All Materials In ContractorS Scope Of Supply). 22 Each 710 15620 149 01Gc.15 Misc. Civil And Structural Works For U/G Piping And Other Civil Works 150 01Gc.15.1 Providing And Laying Brick Masonry With Locally Available Bricks Of Specified Class (Brick Of Class Lower Than Specified Shall Not Be Accepted) In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) In One Or More Brick Thickness And In Any Shape In Foundation And Plinth For Valve Pits, Drains, Circular/Square Maholes, Wing Walls, Etc. Including Providing Recesses, Openings, Etc. Including Curing, Finishing The Joints Flush Below Ground Level And Raking Out Joints In Plinth With All Labour And Material, Etc. Complete As Per Drawings, Specifications And Direction Of Engineer-In- Charge. For Following Brick Class. 151 01Gc.15.1.2 All Materials Including Cement Supplied By The Contractor And Following Brick Class 152 01Gc.15.1.2.1V1 Brick Class 5 10 M³ 10920 109200 153 01Gc.15.6 Supplying And Fixing In Position Medium/ Heavy Duty Ci Manhole Frame With Lugs And Cover Conforming To Is-1726 Including Breaking Of Brick Masonry Or Concrete Surface To Receive Frame With Lugs And Making Good The Same With Cm 1:3 Including Applying Two Coats Of Anticorrosive Paint Inclusive Of All Labours And Materials Etc. Complete 154 01Gc.15.6.1 Circular Size 500 Mm Dia. Medium Duty Of Grade Md-10 2 Each 9520 19040 155 01Gc.15.6.2 Circular Size 560 Mm Dia. Heavy Duty Of Grade Hd-20 2 Each 15207 30414 156 01Gc.15.8 Providing Cement Mortar Grouting On Brick Masonry / Rcc Wall For Filling Free Space Between Pipe Body And Masonry Wall/Concrete Wall With 1:2 (1 Cement: 2 Sand) Mortar Including Packing, Consolidating, Curing, Finishing, Etc. Complete As Per Drawings Specifications And Directions Of Engineer-In-Charge. 157 01Gc.15.8.2 All Materials Including Cement Supplied By The Contractor. 0.2 M³ 15054 3010.8 158 01Gc.15.11 Supplying, Fabricating And Fixing In Position In Rcc Or Brick Masonry Walls Ms Rungs Made Out Of 20Mm Dia. Reinforcement Bar Of Grade Fe500 Tmt Bar Conforming To Is: 1786 .Including Laying Or Welding To Keep In Proper Position Etc. Complete As Per Drawings, Specifications And Instructions Of Engineer-In-Charge. 40 Each 100 4000 159 01Gc.15.12 Supply Of All Materials, Fabrication And Erection In Position, Funnels, Clean Outs, Plugs, Flame Arrester In Vent Pipe, Bird Mesh In Vent Pipe Etc. Including The Cost Of Cutting, Bolting/Welding, Painting With Two Coats Of Chlorinated Rubber Zinc Phosphate Primer @ 40Μ Dft Per Coat And Finish Painting Consisting Of 2 Coats Of Chlorinated Rubber Paint @ 40Μ Dft Per Coat, Etc. Complete As Per Drawings, Specifications And Direction Of Engineer-In-Charge. 100 Kg 190 19000 Page 21 Of 27 Sl. No. Item No Description Qty Uom Rate Amount 160 01Gc.15.15 Providing 13Mm Thick Average Cement Plaster In Cement Mortar 1:6 (1 Cement: 6 Sand) On Brick Walls/Stone Masonry/Pitching Or On Concrete Surfaces For Manholes, Valves Pits, Culverts, Walls, Etc. Including Cleaning And Preparation Of The Surface, Scaffolding, Curing Etc. For All Depths And Heights Complete As Per Drawings Specifications And Direction Of Engineer-In-Charge. All Materials Including Cement Supplied By The Contractor. 50 M² 430 21500 161 01Gc.15.16 Providing 16Mm Thick Average Cement Plaster In Cement Mortar 1:6 (1 Cement: 6 Sand) On Brick Walls/Stone Masonry/Pitching Or On Concrete Surfaces For Manholes, Valves Pits, Culverts, Walls, Etc. Including Cleaning And Preparation Of The Surface, Scaffolding, Curing Etc. For All Depths And Heights Complete As Per Drawings Specifications And Direction Of Engineer-In-Charge. All Materials Including Cement Supplied By The Contractor. 50 M² 500 25000 162 01Gc.26 Miscellaneous Items 163 01Gc.26.1 Laying Of Random Rubble Masonry In Cement Mortar 1:6 (1 Cement: 6 Coarse Sand) In Any Shape And Thickness For Compound Wall, Toe Walls, Drains, Or At Any Other Places As Directed Including Providing Recesses, Openings, Scaffolding, Staging, Raking Out Joints, Curing Etc. By Using Stone Rubble 150Mm To 300Mm Size Available Within Complex Limit, Transportation To Work Site Including Handling, All Leads And Lifts Within Complex Limit, Using At Required Locations, Dressing Of Stones, Etc. All Complete As Per Drawings, Specifications And Directions Of Engineer-In- Charge. 164 01Gc.26.1.3 At All Depths Below And Upto And Inclusive Of Plinth Level. (All Materials Including Cement Supplied By Contractor) 5 M³ 9180 45900 165 01Gc.26.1.4 At All Heights Above Plinth Level. (All Materials Including Cement Supplied By Contractor) 5 M³ 10872 54360 166 01Gc.26.2 Laying Of Random Rubble Masonry In Cement Mortar 1:6 (1 Cement: 6 Coarse Sand) In Any Shape And Thickness For Compound Wall, Toe Walls, Drains, Or At Any Other Places As Directed Including Providing Recesses, Openings, Scaffolding, Staging, Raking Out Joints, Curing Etc. By Breaking Big Stones/Boulders Available Within Complex Limit To Required Size, Dressing Including Making Required Size Bond, Through Stones, Corner Stones, Quoin Etc. Transportation To Work Site With All Leads And Lifts Within Complex Limit, Handling Etc. And Using At Required Locations All Complete As Per Drawings, Specifications And Directions Of Engineer-In-Charge. 167 01Gc.26.2.3 At All Depths Below And Upto And Inclusive Of Plinth Level. (All Materials Including Cement Supplied By Contractor) 5 M³ 6170 30850 168 01Gc.26.2.4 At All Heights Above Plinth Level. (All Materials Including Cement Supplied By Contractor) 5 M³ 7680 38400 169 01Gc.26.18 Supplying & Laying 60Mm Thick Interlocking Paver Blocks For Footpaths And Any Other Place Etc. Including Providing 40 Mm Thick Sand Filling Below Paver Blocks Including Compaction Of Sand Layer, Filling The Joints By Dry Sand, Providing Precast Kerb Stone Of Pcc M 30 At Edges And At Every 6.0M Across The Foot Path, Including Preparation Of Compacted Base/ Sub Base Etc. All Complete As Per Drawing, Standard, Specification And Directions Of Engineer- In-Charge. (All Material Including Cement Supplied By Contractor, Paver Blocks Shall Confirm To Category A As Per Irc Sp63. Colour And Shape Of Paver Block Shall Be As Per Owner Requirement.). 100 M² 990 99000 Page 22 Of 27 Sl. No. Item No Description Qty Uom Rate Amount 170 01Gc.26.27 Supplying & Laying Of Random Rubble Pitching 300Mm Thick In 1:6 Cement Mortar (1 Cement: 6 Coarse Sand) In One Layer For Embankments, Road Side Slopes, Holding Ponds Bunds, Drains, Channels Or At Any Other Place As Directed Including Cost Of Stones, All Royalties & Taxes, Transportation To Site With All Leads And Lifts, Dressing, Preparation Of Sub Grade For Pitching, Flush Pointing In 1:4 Cement Mortar (1 Cement: 4 Sand), Curing Etc. Complete As Per Drawings, Specifications And Directions Of Engineer-In-Charge. 171 01Gc.26.27.1 On Sloped/Curved Surface (All Materials Including Cement Supplied By Contractor) 100 M³ 5180 518000 172 01Gc.26.27.2 On Horizontal Surface (All Material Including Cement Supplied By Contractor) 50 M³ 5000 250000 173 01Gc.28 Ndt Testing 174 01Gc.28.1 Dye Penetration / Magnetic Particle Test Performing Of Magnetic Particle Test Or Dye Penetration Test Including Supply Of All Necessary Materials, Equipment And Labour For Carrying Out The Work As Per Specs. And Direction Of Engineer-In -Charge 175 01Gc.28.1.1 Dp Test Length(Bw&Sw) 10 Inch 80 800 176 01Gc.28.1.2 Magnetic Particle Test 10 Inch 120 1200 177 01Gc.32 Dismantling Works 178 01Gc.32.2 Removal Of Existing U/G Piping 179 01Gc.32.2.1 Removal Of Existing U/G Piping Including Excavation In All Types Of Soils Except Soft Rock And Hard Rock, Including Supply Of Any Additional Material Required So As To Expose The Pipes For Removal / Dismantling, Taking All Safety Precautions, Supporting Existing U/G Services, Dewatering Of Surface / Sub-Surface Water As Required To Facilitate Dismantling Of Pipes, Cutting Of Pipes In Appropriate Lengths For Transporting Purpose, Removal Of Soft Material From Bottom Of Trench And Compacting, Backfilling With Available Selected Earth Including Re-Excavating The Deposited Soil Excavated Earlier, Breaking Clods, Laying In Thickness Not Exceeding 15Cms, Watering Rolling And Ramming By Manual Methods / Mechanical Compactors To Achieve 90% Laboratory Maximum Dry Density As Per Is:2720 Part Vii Or 85% Relative Density As Per Is:2720 Part Xiv As Applicable, Stacking Of Serviceable / Unserviceable Material, Transporting And Stacking Of All Piping Material To OwnerS Storage Point, Disposal Of Unserviceable Material Anywhere Outside The Complex Etc. , All Complete As Per Directions Of Engineer-In-Charge.(Disposal Areas Shall Be Arranged By The Contractor At His Own Cost. The Rate Quoted Shall Include All Royalties, Right-Of-Way Etc. Complete.) 180 01Gc.32.2.1.1 For Cs Piping Dismantling, Thickness <=10 Mm , For Following Nominal Sizes 181 01Gc.32.2.1.1.1 Nb Upto 1.5 Inch 50 Inch Mtr 400 20000 182 01Gc.32.2.1.1.2 Nb 2 Inch - 6 Inch 50 Inch Mtr 400 20000 183 01Gc.32.2.1.1.3 Nb 8 Inch - 14 Inch 50 Inch Mtr 400 20000 184 01Gc.32.2.1.1.4 Nb 16 Inch - 24 Inch 50 Inch Mtr 400 20000 185 01Gc.32.2.1.2 For Cs Piping Dismantling, Thickness > =10Mm And <=20 Mm , For Following Nominal Sizes 186 01Gc.32.2.1.2.4 Nb 38 Inch - 48 Inch 50 Inch Mtr 400 20000 187 01Gc.32.3 Dismantling Of Flexible Road Page 23 Of 27 Sl. No. Item No Description Qty Uom Rate Amount 188 01Gc.32.3.1 Dismantling Of Flexible Road Including Shoulder Consisting Of Wearing Course Of Bituminous Premix Carpet And Bituminous Macadam, Base And Sub Base Course Of Wbm / Wmm, Including Supply Of All Tools And Tackles, Labours, Taking All Necessary Safety Precautions Etc., Segregating Of Serviceable / Unserviceable Material, Stacking Of Serviceable Material Anywhere Within Plant Boundary Limit And Disposal Of The Unserviceable Material Anywhere Outside The Plant Boundary Etc. All Complete For All Levels, Leads As Specified And Directed By Engineer-In- Charge.(Disposal Areas Shall Be Arranged By The Contractor At His Own Cost. The Rate Quoted Shall Include All Royalties, Right-Of-Way Etc. Complete.). 10 M³ 620 6200 189 01Gc.32.6 Dismantling/ Removal Of U/G Valves 190 01Gc.32.6.1 Dismantling/ Removal Of Valve Installed In U/G Piping In Pit Including Unbolting, Cutting As Required, Providing Holding/ Pulling Arrangements And Any Other Arrangements Including Providing All Tools And Tackles Required, Taking All Safety Precautions Etc., Complete As Per Specifications Drawings And Direction Of Engineer-In-Charge Including Transportation Of Dismantled Valve, Bolts And Gasket To The OwnerS Storage Point. For Flanged/ Wafer Valves Of Following Nominal Size 191 01Gc.32.6.1.1V1 Nominal Dia 2 Inch 1 Nos 970 970 192 01Gc.32.6.1.1V3 Nominal Dia 6 Inch 1 Nos 2900 2900 193 01Gc.32.6.1.1V4 Nominal Dia 8 Inch 1 Nos 3870 3870 194 01Gc.32.6.1.1V5 Nominal Dia 12 Inch 1 Nos 5810 5810 195 01Gc.32.7 Dismantling Of Chain Link Fence Fabric 196 01Gc.32.7.1 Dismantling Of Existing Chain Link Fence Fabric With Line Wire (Taking All Necessary Safety Precautions) Including Supply Of All Tools & Tackles, Necessary Scaffolding, Consumables, Cutting Of Fixing Hooks/Staples, Making Rolls, Transporting , Stacking At Designated Area/ OwnerS Store Anywhere Within Plant Complex Limit Etc. All Complete For All Levels, Leads As Specified And Directed By Engineer-In- Charge . 10 M² 150 1500 197 01Gc.32.12 Removal Of Existing U/G Rcc Piping Including Excavation In All Types Of Soils Except Soft Rock And Hard Rock, Including Supply Of Any Additional Material Required So As To Expose The Pipes For Removal / Dismantling, Dewatering Of Surface / Sub-Surface Water As Required To Facilitate Dismantling Of Pipes, Cutting Of Pipes In Appropriate Lengths For Transporting Purpose, Removal Of Soft Material From Bottom Of Trench And Compacting, Backfilling With Available Selected Earth Including Re-Excavating The Deposited Soil Excavated Earlier, Breaking Clods, Laying In Thickness Not Exceeding 15Cms, Watering Rolling And Ramming By Manual Methods / Mechanical Compactors To Achieve 90% Laboratory Maximum Dry Density As Per Is:2720 Part Vii Or 85% Relative Density As Per Is:2720 Part Xiv As Applicable, Stacking Of Serviceable / Unserviceable Material, Transporting And Stacking Of All Piping Material To OwnerS Storage Point, Disposal Of Unserviceable Material Anywhere Outside The Complex Etc. , All Complete As Per Directions Of Engineer-In-Charge.(Disposal Areas Shall Be Arranged By The Contractor At His Own Cost. The Rate Quoted Shall Include All Royalties, Right-Of-Way Etc. Complete.) For The Following Pipe Diameter Range. 198 01Gc.32.12.1 For Pipe Diameter Ranging From 300Mm To 600 Mm 10 M 1170 11700 199 01Gc.32.12.2 For Pipe Diameter Ranging From 600Mm To 1000 Mm 10 M 1840 18400 200 01Gc.32.12.3 For Pipe Diameter Ranging From 1000Mm To 1400 Mm 10 M 3170 31700 Page 24 Of 27 Sl. No. Item No Description Qty Uom Rate Amount 201 01Gc.32.13 Dismantling Of Random Rubble Pitching Upto 300Mm Thick On Embankments, Road Side Slopes, Ponds Bunds, Drains, Channels Or At Any Other Place, Including Supply Of All Tools And Tackles, Labours, Taking All Necessary Safety Precautions Etc., Segregating Of Serviceable / Unserviceable Material, Stacking Of Serviceable Material Anywhere Within Plant Boundary Limit And Disposal Of The Unserviceable Material Anywhere Outside The Plant Boundary Etc. All Complete For All Levels, Leads As Specified And Directed By Engineer-In- Charge.(Disposal Areas Shall Be Arranged By The Contractor At His Own Cost. The Rate Quoted Shall Include All Royalties, Right-Of-Way Etc. Complete.). 202 01Gc.32.13.1 On Horizontal Surfaces 10 Sqm 715 7150 203 01Gc.32.13.2 On Sloped Surfaces 10 Sqm 790 7900 204 01Gc.41 Supply, Fabrication And Erection Of Piping(Underground) 205 01Gc.41.10 Underground Sewer System - Rcc Pipes 206 01Gc.41.10.1 Supplying And Laying Underground R.C.C. Pipes Sewers With Socket And Spigot Ends Conforming To Is:458 Of Approved Make, To Proper Grade And Alignment, Including Earthwork In Excavation In All Types Of Soil Except Soft And Hard Rock For Pipe Trenches Upto 2.0M Depth Of Excavation, Etc. Including Dewatering, Shoring And Shuttering If Necessary, Dressing Of Sides, Leveling, Grading And Ramming Of Bottoms, Cutting The R.C.C. Pipes To Required Lengths, Lowering The Pipes, Jointing, Including Connecting The Pipes To Manholes And Grouting The Pipe Body With Manhole Wall Using Cement Mortar 1:2 (1 Cement : 2 Sand), Testing, Draining Of Water And Cleaning Of Pipe After Testing, Backfilling The Trenches With Select Material From Available Excavated Soil Including Re Excavating The Deposited Soil Excavated Earlier Breaking Clods And Laying In Layers Of 15Cm Compacted Thickness , Watering And Compacting With Mechanical Means Like Vibro Rammers Etc. To 90% Standard Proctor Density As Per Is:2720 Part-Vii, Making Good The Surface, Including Cutting Of Roads Wherever Required And Making Good The Same, Disposal Of Surplus Earth/ Unserviceable Material To Demarcated Area Anywhere Within The Complex Limit Etc. Complete For All Depths As Per Drawings, Specifications And Instructions Of Engineer-In- Charge.(All Material Shall Be Supplied By Contractor) For Following Pipe Size (Mm) And Class (Pipe Sizes Are All Internal Diameter Of The Pipes) 207 01Gc.41.10.1.1V26 Dia. (Internal) 1200 Mm Pipe Class Np3 50 M 8380 419000 208 01Gc.41.10.2 Extra Overtime No. 01Gc.41.10.1 Above But For Depth Of Excavation Beyond 2.0M 209 01Gc.41.10.2.1 Depth Of Excavation Beyond 2.0M Upto And Inclusive Of 3.0M 50 M 340 17000 210 01Gc.41.10.2.2 Depth Of Excavation Beyond 3.0M Upto And Inclusive Of 4.0M 50 M 380 19000 211 01Gc.41.10.2.3 Depth Of Excavation Beyond 4.0M Upto And Inclusive Of 5.0M 50 M 430 21500 212 01Gc.99 Miscellaneous Items 213 01Gc.99.01 Miscellaneous Page 25 Of 27 Sl. No. Item No Description Qty Uom Rate Amount 214 01Gc.99.01.Ma01 Earthwork In Filling With Available Earth Inside Refinery Premises For All Heights And Depths For Road Embankments, Shoulders Or Area Filling/ Site Grading Or Any Other Place As Directed To Proper Levels, Slopes, Grades And Camber With Selected Earth Available For All Leads Within Complex Limit Including Re-Excavation Of Earth For All Leads And Lifts, Loading, Unloading, Transportation, Filling, Dozing Etc., Clearing And Stripping As Per Specifications, Uprooting Of Vegetation, Roots And Disposal Of The Shrubs, Bushes, Roots Etc., Breaking Clods, Spreading In Layers Not Exceeding 20 Cm Loose Thickness, Watering, Ramming And Compacting With Power Roller To Give At Least 95% Of Max. Laboratory Dry Density As Per Is:2720 Part-Viii, Providing Testing Apparatus And Testing The Degree Of Consolidation, Dressing And Leveling, Etc.Complete As Per Drawings, Specifications And Directions Of Engineer-In- Charge. (Available Soil Will Be Shown To Contractor Inside The Refinery Premises. The Rate Quoted Shall Not Include Any Royalties, Taxes Etc. As The Earth Is To Be Shifted Locally Inside The Refinery) 10000 M³ 250 2500000 215 01Ar Architecture 216 01Ar.8 Roofing 217 01Ar.8.21 Barricading Of Corrugated Gi Sheet Of 0.8Mm Thickness Providing And Fixing Corrugated Gi Sheet Of 0.8Mm Thickness, Minimum 120 Gsm Coating And Conforming To Is : 277 In Barricading Cladding, Corner Piece, Etc. With 8Mm Dia `J Or `L Type Anticorrosive Polymer Coated Gi Hook, Bolts, Nuts And Polymer Cap, Seal And Thrust Washer Including Cutting To Proper Size, Drilling Holes, Mitering, Laps, Finishing, Providing Anticorrosive Protective Coating On Hooks, Nuts, Bolts Etc. And Maintaining The Same During Project Execution. After Completion Of The Retention Period Mentioned Elsewhere In The Bid Document, All Materials Shall Be Dismantled And Taken Away By The Contractor Outside Plant Boundary To The Complete Satisfaction Of Engineer-In-Charge All Complete As Per The Direction Of Engineer-In-Charge. Supply Of All Material In ContractorS Scope. 800 M² 610 488000 218 01Gg Geotech 219 01Gg.300 Ground Improvement 220 01Gg.300.1 Sand Gravel Mix 221 01Gg.300.1.1 Supplying And Filling Sand Gravel Mix (1:1) With Approved Aggregate Below Road, Rcc Pavement, Manholes, Pits, Foundations, Bedding Of Ug Piping Etc. In Layers Of 150 Mm Loose Thickness (Maximum) Including Watering, Ramming, Rolling, Compacting To Achieve 85% Relative Density As Per Is 2720 Part-Xiv, Quarrying, Royalties, Transportation, Handling, Etc. All Complete As Per Drawings, Specifications And Directions Of Engineer-In-Charge. (The Rate Shall Be Inclusive Of The Cost Of All Labour, Material, Equipment Etc. All Complete) 50 Cum 2770 138500 222 01Gg.300.Md1 Weepholes 223 01Gg.300.Md1.1 Supply And Installation Of Pvc Pipe Of 110Mm Diameter For Weep Holes In Rcc Retaining Wall Wrapped In Geotextile Of Type Terram 1000 / Equivalent Including Taxes, Handling, Transportation, Unloading, Storage Etc. All Complete As Per Specification, Drawings And Instructions Of Engineer-In- Charge 100 M 580 58000 224 01Gg.300.Md2 Graded Gravel Page 26 Of 27 Sl. No. Item No Description Qty Uom Rate Amount 225 01Gg.300.Md2.1 Supplying And Placement Of Graded Gravel Of Size 20Mm Down To 9.1Mm For Providing Drainage Layer As Per Drawing For All Depths And Heights Including Cost Of Material, Royalties, Transportation To Site For All Leads And Lifts, Including Loading, Unloading, Spreading In Layers Of Loose Thickness Not Exceeding 150Mm, Watering, Ramming, Compacting With Mechanical Compactors And/Or Other Equipment All Complete As Per Drawings, Specifications And Direction Of Engineer-In-Charge. 70 M³ 1800 126000 226 01Gg.300.3 Geotextile 227 01Gg.300.3.1 Supplying And Laying Of Geotextile Terram 1000 Or Equivalent For Hard Stand, Road, Rcc Pavement, Foundation Etc. As Directed By The Engineer-In-Charge Including Royalties, Taxes, Handling, Transportation, Unloading, Storage, Stretching, Joining, Lapping, Sewing Etc. All Complete As Per Drawing, Manufactures Specification And Direction Of The Engineer-In-Charge. (The Rate Shall Be Inclusive Of Cost Of All Labour, Material, Equipment Etc., All Complete). 40 Sqm 180 7200 228 01Gg.300.4 Boulder Soling 229 01Gg.300.4.1 Supplying And Laying Of Random Rubble Soling Below Hardstand, Road, Rcc Pavement, Foundation Etc. In Layers Of 200 Mm Loose Thickness (Maximum) With Nominal Size Of Stones 100 Mm To 250 Mm, Filling Of Voids With Small Size Stones And Sand, Including Watering, Ramming, Rolling, Compacting, Quarrying, Royalties, Transportation, Handling Etc. All Complete As Per Specifications, Drawing And Directions Of The Engineer-In-Charge. (The Rate Shall Be Inclusive Of Cost Of All Labour, Material,Equipment Etc., All Complete).
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Contract Date: Ref. Documents Contract Value : 46.99 Lakh
Government Departments No of Bidders 12
Andhra Pradesh View Result →
22.
Public Administrative Department #10831385 Price Bid
Rigbore And Motor Installation With Chamber Near Milan Mandir Ramgaon At Part No 11/33 Under Jaigaon I Gram Panchayat Wthin Kalchini Block Work Id 109549094 Rigbore And Motor Installation With Chamber Near Milan Mandir Ramgaon At Part No 11/33 Under Jaigaon I Gram Panchayat Wthin Kalchini Block Work Id 109549094 , Labour For Boaring Throught Any Type Of Soil For Sinking Tube Well Of Required Dia. With Top Enlargement By Rig Boaring System ( Either By Reserve Circulation Or By Direct Rotary Method) Including Hire Charges And Labour For Rig Machine, Tools And Plants Staging Force Pumping Set And Making Arrangement For Water Required For Boaring Etc Complete And Lowering Of Pipes Strainers, Blind Pipes Etc, Complete. (B) Depth Upto 250 Metre For 150 Mm Dia, Tube Well Inlargement Of 200Mm La (Upto 50M) , (A) Sypply Of E.R.W.M.S.(Electrical Resistant Welded M.S.) Black Pipe Of Of Tata Make (Heavy Quality) As Per Standard Specification, 5 Mm Thick. (Ii) 100 Mm Dia. (Internal) , Supplying, Fitting And Fixing Pvc Pipes Of Approved Make Of Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). With All Necessary Accessories, Specials Viz. Socket, Bend, Tee, Union, Cross, Elbo, Nipple, Longscrew, Reducing Socket, Reducing Tee, Short Piece Etc. Fitted With Holder Bats Clamps, Including Cutting Pipes, Making Threads,Fitting, Fixing Etc. Complete In All Respect Including Cost Of All Necessary Fittings As Required,Jointing Materials And Two Coats Of Painting With Approved Paint In Any Position Above Ground. (Payment Will Be Made On The Centre Line Measurements Of Total Pipe Line Including All Specials. No Separate Payment Will Be Made For Accesories, Specials. Payment For Painting Will Be Made Seperately) . Pvc Pipes , Supply, Installation, Tesing & Lowering Of 2 Hp Water Filled Submersible Pump Motor Set Complete Having Suitable Discharge As Per Yeld Of Well. Submerisble Cable Of 30Mtr 3 Core 2.5 Sqmm That Cable (Finolex) With Moc Ber Chart (Crompon Make Pump) And Necessary Control Panel And Starter As Per Manufacturar Specifications.( Rate Arrived After Quatation Which Is Enclosed) , Collecting Sample Of Water For Bacteriological And Chemical Test From Any Depth At Any Time During Execution Of Work Including Hire And Labour Charges For Tools And Plants And Sterilising The Equipments, Paying All Charges And Fees, Testing Etc. Complete In All Respect As Per Direction , 125 Mm. Thick Brick Work With 1St Class Bricks In Cement Mortar (1:4) In Ground Floor. , Plaster (To Wall, Floor, Ceiling Etc.) With Sand And Cement Mortar Including Rounding Off Or Chamfering Corners As Directed And Raking Out Joints Including Throating, Nosing And Drip Course, Scaffolding/Staging Where Necessary (Ground Floor).[Excluding Cost Of Chipping Over Concrete Surface] (B) 15 Mm Thick Plaster(1:6) , Single Brick Flat Soiling Of Picked Jhama Bricks Including Rammering And Dressing Bed To Proper Level And Filling Joints With Local Sand. , (A) Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm As Directed And Consolidating The Same By Thorough Saturation With Water, Ramming Complete Including The Cost Of Supply Of Sand. (Payment To Be Made On Measurement Of Finished Quantity) , Ordinary Cement Concrete (Mix 1:2:4) With Graded Stone Chips (20 Mm Nominal Size) Excluding Shuttering And Reinforcement,If Any, In Ground Floor As Per Relevant Is Codes.(B) River Bazree , Artificial Stone In Floor, Dado, Staircase Etc.With Cement Concrete (1:2:4) With Stone Chips, Laid In Panels As Directed With Topping Made With Ordinary White Cement (As Necessary) And Marble Dust In Proportion (1:2) I/C Smooth Finishing And Rounding Off Corners And I/C Application Of Cement Slurry Before Flooring Works, Using Cement @ 1.75 Kg/Sqm All Complete I/C All Materials And Labour.In Ground Foor .Ii) 25 Mm Thick. , Neat Cement Punning About 1.5Mm Thick In Wall, Dado, Window Sill, Floor Etc. Note:Cement 0.152 Cu.M Per100 Sq.M. , Makingof Precast Concrete Pillar 125Mmx125 Mm Thickdia Withnecessary Nut And Bolt Etc (Lmr) , Galvanised Corrugated Iron Sheet Work (Excluding The Supporting Frame Work) Fitted And Fixed With 10 Mm. Dia J Or L Hook-Bolts, Limpet And Bitumen Washers And Putty Complete With 150 Mm. End Lap And One Corrugation Minimum Side Lap. (Payment To Be Made On Area Of Finished Work)(Gci Sheet To Be Supplied By Contractor) , Supply & Installation Of Sutable Pump Control Panel With Volt Meter,Amp Meter & Dol Starter With Necessary Relay And Drawing Of Power Line From Main Maximum Up To 25Mtr. , Febrication Of Ms Structre With Base Plate And Fustnut / Jumpnut On The Basepanels On The Structure As Per Standard & Approved Drawing. Thepanels Will Then Be Connected To The Pump, Controller Which In Turn Will Be Connected To The Pump As Well As The Level Indicator Of The Water Tank As Per Direction Of The E.I.C. (Lmr) , Supplying, Fitting And Fixing Alloy Iron With Brass Spindle Bib Cock/ Stop Cock Of Approved Brand And Make, Spray Painted And Tested To 21 Kg Per Sq. Cm. 20 Mm (1 Stop Cock + 2 Bib Cock) , Wood Work In Door And Window Frame Fitted And Fixed In Position Complete Including A Protective Coat Of Painting At The Contact Surface Of The Frame Exluding Cost Of Concrete, Iron Butt Hinges And M.S Clamps. (The Quantum Should Be Correted Upto Three Decimals). (D) Sal : Local. , Providing & Fixing Concrete Sign Board As Per Irc Specification Of Size 900 X 750 X 37 Mm. Thick Made With Rcc 1:1½:3 With Pakur Variety Stone Chips Reinforced With Double Layer Irc Febric (75 X 75 Mm. Mesh) And Fixed With Necessary Nuts & Bolts On Tworc Precast Posts 100 Mm. X 150 Mm. Of Height 2.65 M. Of Which Top 750 Mm. Is Of Section 100 X 13 Mm. And 1.90 Metre Above Gl & 0.75 Metre Below Gl Including Digging Hole, Repacking The Same With Cement Concrete 1:3:6 With Jhama Khoa Or With Localstone Chips Etc. Complete Including Painting Two Coats On Both Faces Lettering Sign Marks Etc. As Per Direction Of The Engineer-In-Charge. (The Rate Is Inclusive Of Cost Of Reinforcement, Concrete, Shuttering, Nuts & Bolts, Washer Etc. Complete.) , Gst @ 18% Of Gross Amount , Labour Welfare Cess @ 1% Of Gross Amount
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
West Bengal View Result →
23.
Public Administrative Department #10831384 Price Bid
Rigbore And Motor Installation With Chamber Near Laxmi Pradhan House At Ns Road Daragaon At Part No 11_35 Under Jaigaon I Gram Panchayat Within Kalchini Block Work Id 109549920 , Labour For Boaring Throught Any Type Of Soil For Sinking Tube Well Of Required Dia. With Top Enlargement By Rig Boaring System ( Either By Reserve Circulation Or By Direct Rotary Method) Including Hire Charges And Labour For Rig Machine, Tools And Plants Staging Force Pumping Set And Making Arrangement For Water Required For Boaring Etc Complete And Lowering Of Pipes Strainers, Blind Pipes Etc, Complete. (B) Depth Upto 250 Metre For 150 Mm Dia, Tube Well Inlargement Of 200Mm La (Upto 50M) Upto 50.0 Mtr , (A) Sypply Of E.R.W.M.S.(Electrical Resistant Welded M.S.) Black Pipe Of Of Tata Make (Heavy Quality) As Per Standard Specification, 5 Mm Thick. (Ii) 100 Mm Dia. (Internal) , Supplying, Fitting And Fixing Pvc Pipes Of Approved Make Of Schedule 80 (Medium Duty) Conforming To Astmd - 1785 And Threaded To Match With Gi Pipes As Per Is : 1239 (Part - I). With All Necessary Accessories, Specials Viz. Socket, Bend, Tee, Union, Cross, Elbo, Nipple, Longscrew, Reducing Socket, Reducing Tee, Short Piece Etc. Fitted With Holder Bats Clamps, Including Cutting Pipes, Making Threads,Fitting, Fixing Etc. Complete In All Respect Including Cost Of All Necessary Fittings As Required,Jointing Materials And Two Coats Of Painting With Approved Paint In Any Position Above Ground. (Payment Will Be Made On The Centre Line Measurements Of Total Pipe Line Including All Specials. No Separate Payment Will Be Made For Accesories, Specials. Payment For Painting Will Be Made Seperately) . Pvc Pipes , Supply, Installation, Tesing & Lowering Of 2 Hp Water Filled Submersible Pump Motor Set Complete Having Suitable Discharge As Per Yeld Of Well. Submerisble Cable Of 30Mtr 3 Core 2.5 Sqmm That Cable (Finolex) With Moc Ber Chart (Crompon Make Pump) And Necessary Control Panel And Starter As Per Manufacturar Specifications.( Rate Arrived After Quatation Which Is Enclosed) , Collecting Sample Of Water For Bacteriological And Chemical Test From Any Depth At Any Time During Execution Of Work Including Hire And Labour Charges For Tools And Plants And Sterilising The Equipments, Paying All Charges And Fees, Testing Etc. Complete In All Respect As Per Direction , 125 Mm. Thick Brick Work With 1St Class Bricks In Cement Mortar (1:4) In Ground Floor. , Plaster (To Wall, Floor, Ceiling Etc.) With Sand And Cement Mortar Including Rounding Off Or Chamfering Corners As Directed And Raking Out Joints Including Throating, Nosing And Drip Course, Scaffolding/Staging Where Necessary (Ground Floor).[Excluding Cost Of Chipping Over Concrete Surface] (B) 15 Mm Thick Plaster(1:6) , Single Brick Flat Soiling Of Picked Jhama Bricks Including Rammering And Dressing Bed To Proper Level And Filling Joints With Local Sand. , (A) Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm As Directed And Consolidating The Same By Thorough Saturation With Water, Ramming Complete Including The Cost Of Supply Of Sand. (Payment To Be Made On Measurement Of Finished Quantity) , Ordinary Cement Concrete (Mix 1:2:4) With Graded Stone Chips (20 Mm Nominal Size) Excluding Shuttering And Reinforcement,If Any, In Ground Floor As Per Relevant Is Codes.(B) River Bazree , Artificial Stone In Floor, Dado, Staircase Etc.With Cement Concrete (1:2:4) With Stone Chips, Laid In Panels As Directed With Topping Made With Ordinary White Cement (As Necessary) And Marble Dust In Proportion (1:2) I/C Smooth Finishing And Rounding Off Corners And I/C Application Of Cement Slurry Before Flooring Works, Using Cement @ 1.75 Kg/Sqm All Complete I/C All Materials And Labour.In Ground Foor .Ii) 25 Mm Thick. , Neat Cement Punning About 1.5Mm Thick In Wall, Dado, Window Sill, Floor Etc. Note:Cement 0.152 Cu.M Per100 Sq.M. , Makingof Precast Concrete Pillar 125Mmx125 Mm Thickdia Withnecessary Nut And Bolt Etc (Lmr) , Galvanised Corrugated Iron Sheet Work (Excluding The Supporting Frame Work) Fitted And Fixed With 10 Mm. Dia J Or L Hook-Bolts, Limpet And Bitumen Washers And Putty Complete With 150 Mm. End Lap And One Corrugation Minimum Side Lap. (Payment To Be Made On Area Of Finished Work)(Gci Sheet To Be Supplied By Contractor) , Supply & Installation Of Sutable Pump Control Panel With Volt Meter,Amp Meter & Dol Starter With Necessary Relay And Drawing Of Power Line From Main Maximum Up To 25Mtr. , Febrication Of Ms Structre With Base Plate And Fustnut / Jumpnut On The Basepanels On The Structure As Per Standard & Approved Drawing. Thepanels Will Then Be Connected To The Pump, Controller Which In Turn Will Be Connected To The Pump As Well As The Level Indicator Of The Water Tank As Per Direction Of The E.I.C. (Lmr) , Supplying, Fitting And Fixing Alloy Iron With Brass Spindle Bib Cock/ Stop Cock Of Approved Brand And Make, Spray Painted And Tested To 21 Kg Per Sq. Cm. 20 Mm (1 Stop Cock + 2 Bib Cock) , Wood Work In Door And Window Frame Fitted And Fixed In Position Complete Including A Protective Coat Of Painting At The Contact Surface Of The Frame Exluding Cost Of Concrete, Iron Butt Hinges And M.S Clamps. (The Quantum Should Be Correted Upto Three Decimals). (D) Sal : Local. , Providing & Fixing Concrete Sign Board As Per Irc Specification Of Size 900 X 750 X 37 Mm. Thick Made With Rcc 1:1½:3 With Pakur Variety Stone Chips Reinforced With Double Layer Irc Febric (75 X 75 Mm. Mesh) And Fixed With Necessary Nuts & Bolts On Tworc Precast Posts 100 Mm. X 150 Mm. Of Height 2.65 M. Of Which Top 750 Mm. Is Of Section 100 X 13 Mm. And 1.90 Metre Above Gl & 0.75 Metre Below Gl Including Digging Hole, Repacking The Same With Cement Concrete 1:3:6 With Jhama Khoa Or With Localstone Chips Etc. Complete Including Painting Two Coats On Both Faces Lettering Sign Marks Etc. As Per Direction Of The Engineer-In-Charge. (The Rate Is Inclusive Of Cost Of Reinforcement, Concrete, Shuttering, Nuts & Bolts, Washer Etc. Complete.) , Gst @ 18% Of Gross Amount , Labour Welfare Cess @ 1% Of Gross Amount
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
West Bengal View Result →
24.
Communications and Information Technology  #10822903 Price Bid
E-Tender For Ofc Construction Work For Fpoi Shifting Under Nofn Project In Lunkaransar , Sridungargarh And Khajuwala Block Of Bikaner Ssa , Excavation Of Trenches/Hdd Excavation Trenches Up To A Depth Of 1 . 65 M And Back Filling The Excavated Trenches After Laying The Hdpe/Plb Pipe With Or Without Protection As Per Tender Specification ( Oft ) , In Kuchcha Soil ( Oftk ) , In Pucca Soil ( Oftp ) , In Rocky Soil ( Oftr ) , Excavation And Trenching Including Manual Boring And Reinstatement As Per Construction Specification Of The Tender To A Depth Of 1 . 65Cm In Bituminized/Concrete/Set Stone ( Rate Per Meter ) For Single Plb Pipe ( Ofb ) , Hdd - Laying Of Plb Hdpe Duct By Hdd Method At A Depth Of 1 . 65Cm Or More ( For Single Plb Pipe ) ( Ofh ) , Laying Of Plb Hdpe Pipe /Gi Pipes/ Rcc Pipes/ Dwc , Laying Of Single Plb Hdpe Pipes /Coil , Coupled With Coupler ( Lph ) , Laying And Fixing Of Gi Pipes N Trenches With Plb Hdpe Pipes/Coils Inside ( Lgit ) , Laying And Fixing Of Gi Pipes ( Medium Duty Class Having Inner Diameter Of 50Mm , As Per Isi Specifications ) In Trenches On Bridges Nad Culverts With Plb Hdpe Pipes/Coils Inside ( Lgic ) , Laying Of Full Round Rcc ( Isi Mark ) /Dwc Pipe ( As Per Existing Tec Gr No . Gr/Dwc-34/01 Sep 2007 With Latest Amendments ) In Trenches Over Plb Hdpe Pipes/Coils , On Culverts/Bridges/Nulla And For Cases Where Cable Is Laid At Less Depth ( Wherever Required ) ( Lfrc ) , Laying Of Split Rcc ( Isi Mark ) /Dwc Pipe ( As Per Existing Tec Gr No . Gr/Dwc-34/01 Sep 2007 With Latest Amendments ) In Trenches Over Plb Hdpe Pipes/Coils , On Culverts/Bridges/Nulla And For Cases Where Cable Is Laid At Less Depth ( Wherever Required ) ( Lsrc ) , Providing Cement Concrete 1:2:4 At Wheel Guard Of Bridge/ Culvert Over The Toe Or In The Trench For Protection ( Pcct ) , Of Cable Laying By Pulling/ Blowing , Laying Of Of Cable By Pulling / Blowing Method Including Opening Of Manhole , Sealing Of Plb Hdpe Pipes ( Ofpb ) , Splicing Of Of Cable ( 24 Fibre ) , Splicing Of Fibers In New Joint Chambers For Making Straight Joints On New Routes Or At Fpoi And End To End Testing Of All Fibers After Splicing Including Installation Cost For 24 F Of Cable ( Ssbj ) , Splicing Of All The Fibers Of 24 F Of Cable In The Fiber Termination Box /Wsc At The Gram Panchayats And Testing All The Fibers For Continuity . This Will Also Include Installation /Mounting Of The Ftb As Specified ( Sftb ) , Jointing Chamber , Construction Of Bricks Joint Chamber As Per Specification And The Construction Practice As Specified In The Tender Document ( Jcbr ) , Construction Of Pr Fabricated Rcc Joints Chamber As Per Specification And The Construction Practice As Specified In The Tender Document ( Jcrc ) , Route Indicator , Supply And Fixing Of Rcc/Stone Route/Joint Indicator By Contractor With Painting And Sign Writing As Per Tender Specification ( All Required Materials Shall Be Arranged By The Contractor ) ( Risr ) , Restoration Of Road Surface , Road Restoration Work With Bituminous Macadam For Semi Grouting 50 Mm Thick And Premix Carpet Surfacing 25Mm Thick Over The Grouted Surface ( Total Up To 75Mm Thick ) , Including Supply Of Asphalt Etc . To Evenly Match The Road , Including Consolidation And Rolling As Per Standard Specification Of Dsr 1997 . ( Rrsb ) , Road Restoration Work With Cement Concrete 1:4:8 Mix For Thickness Varying From 150Mm To 225 Mm , Including Supply Of Concrete To Evenly Match The Road ( Rrsc ) , Route Index Diagram , Supply Of Route Index Diagram ( 6 Sets ) In Hard As Well As Soft Copy On Cd For Complete Olt . ( Drid ) , Videography Of The Route On Which Cable Is Laid ( Vlcr ) , Laying Of Of Cable In Building ( Leading In Work ) , Installation Of Pvc Flexible Conduit In Corridor/Risers/Exchange Premesis And Laying Of Of Cable Through It ( Leading In Work ) ( Loib ) , Mounting Of Fdms At Olt Location , Physical Mounting Of Fdms On Wall At Olt Locations ( Mfdo ) , Recovery Of Store , Recovery Of 24 F Cable Drum
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
25.
Communications and Information Technology  #10820540 Price Bid
Supply Of Rcc Chamber And Indicator
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
26.
Public Administrative Department #10809106 Price Bid
Tender For Electric Work In Municipal Area Sultanpur- 1 Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR Poles with Octagonal Cross Section 9 Mtr. 2 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .Single arm overhang 3 Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. 4 LED Street Light fixture with Minimum lumen output 3700 lm 5 LED Street Light fixture with Minimum lumen output 5600 lm 6 LED Street Light fixture with Minimum lumen output 8700 lm 7 LED Street Light fixture with Minimum lumen output 15000 lm 8 Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . High Power LED Flood Light Minimum lumen output 25000 lm 9 Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discoms standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 75mm x 90mm 10 Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 11 Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discoms specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR LT cross arm 600 mm long with clamp 12 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq.mm 13 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 14 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 A to 32 A rating 15 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 50/63 A rating 16 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 80 Amp 17 SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSRup to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 18 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approve One day & week reserve (digital type )d by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 19 Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 8.0 Mtr long PCC pole of 200 Kg Working Load 20 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discoms standard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 100 mm x 70 mm 21 Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3 X 25 sq. mm. + 1X25 sq. mm. (insulated) 22 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 2 core 23 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4 core 24 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 3.5core 25 P & F of IP 55 protected light controlled switch based oninfrared sensing and daylight with built in over loadprotection, timer to switch OFF at preselected time.Switch shall have 7 day power backup withouthampering of preset time and over ride facility formaintenance purpose Suitable for 15 kw load (three phase) includingcontactor, MCB, cable glands, terminal block andlocking arrangement 26 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 mm Dia. 27 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 40 mm Dia. 28 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6 SWG G.I. ( Hot Dipped ) Wire 29 Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 30 Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM. 31 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR B class 50mm dia 33 Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer Cement Concrete Grade M-15 and above and PCC blocks 34 Providing & Fixing of ISO certified company made bolted type/ Din type HBC (High breaking capacity) fuse links of 80 KA breaking capacity,as per PWD specification for electrical Works conforming to IS:13703 in the existing fuse base, fuse switch unit etc. of the following type and rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 63 A to 160 A Size 00 35 Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 6.0 sq.mm 36 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or teeconnections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 37 LINE MAN/WIRE MAN Annual Rate Contract of regular opration and maintence and Changing faulty spare parts, sheets, Wire and Door Switch of all existing pannel complete for 12 month (30 PENNEL) 38 Annual Rate Contract of regular opration and maintence of all type LED street lights fixure with all wattage (20,40,70,130,200)/ HIGH MAST with Complate materials, Drivers, Glass, Chip, Wire, etc Complate Including Line Maintence For 12 Month Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
27.
Rural Development #10802609 Price Bid
Tender For Providing Various Types Of Material For Various Work At Jategaon Khd In Fin Year 2025-26 -2 wash sand 3 sand 4 mudroom 5 vertical 8 MM 6 vertical 10 MM 7 vertical 12 MM 8 vertical 16 MM 9 grit powder 10 Cement 53 Grade 11 floor tandoor kota 12 Farshi Shahabadi 13 styles 14 glass styles 15 Steel 8 MM 16 Steel 10 MM 17 Steel 12 MM 18 Steel 16 MM 19 SQUARE BAR 8,10,12,16 MM 20 voiding wire 21 screw j hook 22 FLY ASH Vita 23 chemical 24 blocks 25 grill window 26 cement square 27 Kadapa 28 Chamber 2 3 29 Chamber 2 x 2 30 Chamber 3 x 3 31 Chamber 4 x 4 32 Paver Block 60 mm 33 Paver Block 80 mm 34 GI Pipe 2 x 2 35 GI Pipe 1 inch x 1 inch 36 GI Pipe 1 x 1 37 GI Pipe 1.5 x 1.5 inch 38 GI Pipe 3 x 1.5 inch 39 GI Pipe 3 x 3 40 GI Pipe 1 x 3 41 GI Pipe 1 x 2 42 GI Pipe 2 x 4 43 C Angle 25 x 3 44 C Angle 50 x 5 45 C ANGLE 40 X 5 46 C ANGLE 65 X 5 47 F Strip 18 X 4 48 F Strip 30 X 5 49 F Strip 20 X 3 50 GI SEET COATING 51 CHAINLIN FENCING 52 I BEAM 100 X 50 53 C BEAM 75 X 40 54 MS PLATE 55 6 MM MS BAR 56 MS PIPE 2 57 MS PIPE 1 58 MS PIPE 0.5 59 RCC PIPE 200 NP 60 RCC PIPE 300 NP 61 RCC PIPE 450 NP 62 ​​5 HP Electric Motor Jalpari 63 1 HP Electric Motor Jalpari 64 7.5 H 12.5 HP Electric Motor Jalpari 65 12.5 HP Electric Motor Jalpari 66 Cable 3 Core 67 Triple Layer Water Tank 68 63 MM PVC PIPE 69 63 MM L BO 70 63 MM T 71 63 MM REDUCER 72 63 MM COUPLING 73 63 MM FTA 74 63 MM MTA 75 63 MM HDPE PIPE 76 75 MM PVC PIPE 77 75 MM L BO 78 75 MM T 79 75 MM REDUCER 80 75 MM COUPLING 81 75 MM FTA 82 75 MM MTA 83 75 MM HDPE PIPE 84 90 MM PVC PIPE 85 90 MM LBO 86 90 MM T 87 90 MM COUPLING 88 90 MM REDUCER 89 90 MM FTA 90 90 MM MTA 91 90 MM HDPE PIPE 92 4 Inch PVC PIPE 93 4 Inch LBO 94 4 Inch T 95 4 Inch COUPLING 96 4 Inch REDUCER 97 4 Inch FTA 98 4 Inch MTA 99 4 Inch HDPE PIPE 100 1 HP STARTER 101 3 HP STARTER 102 7.5 HP STARTER 103 12.5 HP STARTER 104 1.25 Inch HDPE 105 6 INCH PVC PIPE 106 6 Inch L Bow 107 6 Inch T 108 6 inch coupling 109 6 inch reducer 110 6 inch fta 111 6 Inch MTA 112 6 inch HDPE pipe 113 1/2 Inch UPVC Pipe 114 1/2 Inch L Bow UPVC 115 1/2 Inch T UPVC 116 1/2 Inch Coupling UPVC 117 1/2 Inch Reducer UPVC 118 1/2 Inch Cock Tap UPVC 119 1/2 Inch Cock UPVC 120 2 Inch Cock PVC 121 3 Inch Cock PVC 122 NON RETURN VOLVE 123 Air Wall 124 SWITCH WALL 125 Thibak Bundle 16 MM 126 joiner 127 Lokhandi Flynch 2.5 Inch 128 Lokhandi Flanch 3 Inch 129 Lokhandi Flanch 4 Inch 130 solution 131 nylon string 132 1.5 HP Motor 133 Cement Color 25 KG 134 Cement Color 10 KG 135 Cement Color 5 KG 136 Distemper 05 Liters 137 distemper 10 liter 138 distemper 20 liter 139 Primer Outer 140 primer inner 141 ACROLIC COLOR 142 emulsion color 143 APEX COLOR 144 DAM PROOF 145 Krayak Sil Powder 146 Cryak Sil Liquid 147 oil paint 148 APEX ROYAL COLOR 149 ASIAN PAINTS ACE 150 ASIAN PAINTS STAR 151 terracotta color 152 plastic paints 153 Turfen 154 polished paper 155 brush color 156 wire brush 157 LED LIGHT 18 VAT 158 LED LIGHT 20 VAT 159 LED FLOOD LIGHT 36 VAT 160 LED FLOOD LIGHT 50 VAT 161 LED FLOOD LIGHT 100 VAT 162 LED FLOOD LIGHT 150 VAT INCLUDING LAMP WITH PF7 0.95 CLASS IP 65 AND ABOVE 163 FRP BOX SIZE 300 MM X 200 MM X 125 MM 2.7 MM THICK COMPLETE 164 SUPPLYING ERECTING AND MARKING DPMCB 6 A TO 32 A B SERIES 165 SUPPLYING AND ERRECTING STREET LIGHT BRACKET FOR ERECTION OF DOUBLE FITTING TUBULOR WELDED POLE WITH 40 MM DIA 1.0 M LONG B GRADE GI PIPE ALONG WITH POLE CAP OF 125 MM DIA 600 166 2 CORE CABLE 10 SQ MM ALUMINUM CONDUCTOR WITH CONTINUOS 5.48 SQ MM (12 SWG) 167 SUPPLYING AND ERRECTING COST IORN CABLE INDICATOR PLOT BURIED ALONG WITH ROUTE OF CABLE PVC XLPE ARMAUED CABLE 168 9 MTR HIGHT OCTAGONAL POLE WITH FOUNDATION BOLTS HAVING BOTTOM OF 155 MM A/F TOP 70 MM A/F PROVIDED FOUNDATION 169 GI PIPE 40 MM DIA OR 20 MM DIA GI ROD 170 2 X 4 SQM FR COPPER PVC INSULATED WIRE LAID IN PROVIDED CONDUCT AND TRACKING INSIDE POLE BUS BARS 171 GI PIPE A CLASS 40 MM DIA ERECTED FOR ENCLOSING XLPE ARMOR CABLEON WALL POLE 172 1.20 M X 0.90 M INFORMATION 130 ARD 1.25 MM THICK Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
28.
Communications and Information Technology  #10795880 Price Bid
Tender For Ofc Rehabilitation / Ofc Patch Work In Rajsamand District Of Udaipur Oa; 1 Excavating trenches up to a depth of 1.65m and back fillingthe excavated trenches after laying the HDPE/PLB pipe with or without protection as per tender specification ( OFT/ (OFCT) 2 i) In Non Rocky Soil /Soft Soil/Kachcha soil( OFTK ) 3 ii) In Pucca Soil 4 ii) In Soft Rock Soil /Disintegrated (D.I.) Soil ( OFTP ) 5 iii) in Rocky soil/Hard Rock Soil ( OFTR ) 6 Excavation and trenching including tunneling or boring and reinstatement as per construction specification of tender to a depth of 1.65 mtrs in bituminized/ concrete/set stone (rate per meter) for single PLB pipe. ( OFB ) 7 Laying of PLB HDPE duct by HDD method at a depth of 1.65 mtrs or more ( for single PLB pipe ) in Soft Soil ( OFHS ) 8 Laying of PLB HDPE duct by HDD method at a depth of 1.65 mtrs or more (for single PLB pipe) in Rocky Soil ( OFHR ) 9 Road/Rail crossing through horizontal boring method and inserting 65/40 Dia G.I./DWC pipes & pushing HDPE Pipe/Coils inside & drawing PP rope. ( (GIHB) ) 10 Laying of PLB HDPE Pipe/GI Pipes/RCC Pipe/DWC 11 Laying of single PLB HDPE Pipes/Coils, coupled with coupler ( LPH / (HDPE) ) 12 Laying and fixing of G.I. Pipes (Medium duty class having inner diameter of 50mm, as per ISI specifications) in trenches with PLB pipe HDPE Pipes/Coils inside ( LGIT /(GIPT1) ) 13 Laying and fixing G.I. pipes(Medium duty class having inner diameter of 50mm, as per ISI specification) in trenches on Bridges and Culverts with PLB HDPE pipes/Coils inside ( LGIC /(GIBC) ) 14 Laying and fixing of G.I.65mm Pipes (Medium duty class having inner diameter of 50mm, as per ISI specifications) in trenches with PLB pipeHDPE Pipes/Coils inside (G.I. Pipe supplied by Contractor) ( (GIPT2) ) 15 Laying of full round RCC (ISI mark)/DWC pipe (As per existing TEC GR no. GR/DWC-34/01 sep-2007 with latest amendments) in trenches over PLB HDPE pipes/coils, on culverts/bridges/Nula and for cases where cable is laid at less depth (wherever required) ( LFRC / (RCCT(A)) ) 16 Laying of half- split RCC(ISI Mark)/DWC pipe (as per existing TEC GR no GR/DWC-34/01 sep 2007 with latest amendment) in trenches over PLB HDPE pipes /coils, on culverts/ bridges/nula/and for cases where cable is laid at less depth (wherever required) ( LSRC /(RCCT(B)) ) 17 Providing cement concrete 1:2:4 at Wheel guard of bridge/culvert over the toe or in the trench for protection 25cm* 25cm over 40mm Dia PLB pipe ( PCCT ) 18 Providing cement concrete 1:2:4 over the PLB HDPE PIPE with wire mesh (as per specification of tender) in the trenches for protection, where the depth is less than 120 Cms(CementConcrete as perspecification) 25cm* 25cm over 40mm Dia PLB pipe ( PCCM ) 19 Cable laying by pulling/blowing 20 Laying of OF Cable by Pulling/blowing method including opening of Manhole, Sealing of PLB HDPE Pipes (6F,12F,24F) ( OFPB / (OFCP) ) 21 Laying of 48F OF Cable by Pulling/blowing method including opening of Manhole, Sealing of PLB HDPE Pipes ( OFPB / (OFCP) ) 22 Laying of 96F & Above OF Cable by Pulling/blowing method including opening of Manhole, Sealing of PLB HDPE Pipes ( OFPB / (OFCP) ) 23 Pulling/blowing method of any type of OF Cable in existing Doct/HDPE Pipes ( OFPB / (OFCP) ) 24 Splicing of OF Cable 25 Splicing of fibers in existing/new Joint chambers for making straight/branch joints on new routes or at FPOI and end to end testing of all fibers after splicing. Including installation cost (6F,12F & 24F) ( SSBJ / (OFST) ) 26 Splicing of all the fibers of 6F, 12F & 24F) OF cable in the fibre termination box at the Gram Panchayats and testing all the fibers for continuity. This will also include installation/mounting of the FTB/WSC as specified. ( SFTB /(OFST) ) 27 Splicing of fibers (48F) in existing/new Joint chambers for making straight/branch joints on new routes or at FPOI and end to end testing of all fibers after splicing. Including installation cost ( SSBJ / (OFST) ) 28 Splicing of all the fibers of (48F) OF cable in the fibre termination box (FDMS) at the Exchanges and testing all the fibers for continuity. This will also include installation/mounting of the FTB/WSC as specified. ( SFTB / (OFST) ) 29 Splicing of fibers (96F) in existing/new Joint chambers for making straight/branch joints on new routes or at FPOI and end to end testing of all fibers after splicing. Including installation cost ( SSBJ / (OFST) ) 30 Splicing of all the fibers of (96F) OF cable in the fibre termination box (FDMS) at the exchanges and testing all the fibers for continuity. This will also include installation/mounting of the FTB/WSC as specified. ( SFTB / (OFST) ) 31 Splicing of all the fibers of (128F) OF cable in the fibre termination box (FDMS) at the exchanges and testing all the fibers for continuity. This will also include installation/mounting of the FTB/WSC as specified. ( SFTB / (OFST) ) 32 Splicing of all the fibers of (128F) OF cable in the fibre termination box (FDMS) at the exchanges and testing all the fibers for continuity. This will also include installation/mounting of the FTB/WSC as specified. ( SFTB / (OFST) ) 33 Jointing Chamber 34 Construction of Bricks joints chamber as per specification and the construction practice as specified in the tender document ( JCBR ) 35 Construction of pre fabricated RCC joints chamber as per specification and the construction practice as specified in the tender document ( JCRC ) 36 Digging of pits for Existing Joint Chamber, filling of Joint Chamber with clean sand & back filling of jointing pit as per tender specifications. ( JCE ) 37 Route Indicator 38 Digging of pit 1 mtr towards jungle side on each main hole/joint chamber for fixing of route/joint indicator fixing & concreting of route/joint /route indicator painting & sign writing of route including supply of Joint/route indicator ( RISR / (ORJF) ) 39 Restoration of road surface 40 Road restoration work with bituminous macadam for semi grouting 50mm thick and premix carpet surfacing 25mm thick over the grouted surface( total up to 75mm thick ), including supply of asphalt etc.to evenly match the road, including consolidation and rolling as per standard specification of DSR 1997 ( RRSB ) 41 Road restoration work with cement concrete 1:4:8 mix for thickness varying from 150mm to 225mm, including supply of concrete to evenly match the road. ( RRSC ) 42 Route Index Diagram 43 Supply of route index diagram in hard as well as soft copy on cd for complete Block. (DRID) 44 Videography of the route on which cable is laid (VLCR) 45 Laying of OF Cable in building (Leading in work) 46 Laying of OF cable in corridor/risers/exchange premises (leading work) ( LOIB ) 47 Recovery of Store 48 Recovery of empty 24F cable Drum ( RECD )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
29.
Rural Development #10782425 Price Bid
Supplying Of Following Item Of Gram Panchayat Nandura Kh Tq. Ahmedpur Dist Latur , Rcc Cement Rcc Cement Bench For 3 Seater + 4 Ft Length + With Metalic Colour , Rcc Cement Rcc Cement Bench For 3 Seater + 4 Ft Length + With Metalic Colour + Relaxation Sofa , Computer I 3 10Th Gen New 2022 Inspiron Dt 3891 Mt || Intel Core I3-10Th Generation || 8Gb Ram || 1Tb Hdd +256 Gb M.2 Ssd || Windows 11 Home+Office 2021 || Dell E2216hv Fhd Monitor || No Dvd Drive || 1 Yr Warranty , Dust Bin Plastic 240 Liter Trash Bin Green+ Blue | Wheeled Dustbin | Waste Bin | Trash Bin | Large Size Plastic Bin | Outdoor Dustbin , Dust Bin Plastic 135 Liter Trash Bin Green+ Blue | Wheeled Dustbin | Waste Bin | Trash Bin | Large Size Plastic Bin | Outdoor Dustbin , Dust Bin Plastic 90 Liter Trash Bin Green+ Blue | Waste Bin | Trash Bin | Large Size Plastic Bin | Outdoor Dustbin , Dust Bin Dust Bin Capacity 20 Litres Material Plastic Opening Mechanism Pedal Material Used In It Is Plastic Heat And Crack Resistance With Uv Stablized , Dust Bin With M S Stand Double Big Plastic 90 Liter Trash Bin Green+ Blue | Waste Bin | Trash Bin | Large Size Plastic Bin | Outdoor Dustbin + M S Stand + Two Dust Bins + Two Dustbins , Dust Bin With M S Stand Single Big Plastic 90 Liter Trash Bin Green+ Blue | Waste Bin | Trash Bin | Large Size Plastic Bin | Outdoor Dustbin + M S Stand , Dust Bin Capacity 50 Litres Material Plastic Opening Mechanism Pedal Material Used In It Is Plastic Heat And Crack Resistance With Uv Stablized , Fan Included Components Motor, Down Rod, Blade Set, Shackle, Canopy Mounting Type Downrod Mount, Indoor/Outdoor Usage Indoor Item Dimensions Lxwxh 27 X 21 X 17 Centimeters Material Metal Controller Type Button Control Number Of Blades 3 , Thermal Fogging Machine Stainless Steel Thermal Fogging Machine With Carburetor And Self Start Option (Silver)+Working Environment: Temperature Between – 10 Degrees To 35 Degree C, Air Humidity 80% - 30% Spraying Amount: 80 - 120L/H Fuel Tank Volume: 2.0L, Fuel Consumption: 3.0L/H The Weight Of The Whole Machine: 6.5/10.5Kg The Fuel To Be Used: Gasoline (93# Or Above Lead-Free Gasoline, Not To Add Any Lubricant Agent) , Lgnition Power: 12V Rechargeable Batteries , Computer Chair Featherlite Astro High Back Mesh Home & Office Ergonomic Chair With, Adjustable Lumbar Support, Adjustable Armrest & Diy (High Back, Black) , Executive Office Chair High Back Cushion Office Chair (1 Year Warranty, New Launch 2022) (Premium Leatherettte Material And Super Comfy , Executive Visitor Chair Executive Visitor Chair With Arm Rest With Steel Frame And Cushioned Seat Back , Plastic Chair Plastic Chair Material Plastic, Product Dimensions 61D X 79W X 56.5H Centimeters, Weight Bearing Capacity : 125 Kg, Weight 2400 Grams, Back Style Floral Back Furniture Finish Beige Color. , Plastic Chair Material Plastic, Product Dimensions 61D X 79W X 56.5H Centimeters, Weight Bearing Capacity : 125 Kg, Weight 2400 Grams,Back Style Floral Back Furniture Finish Beige Color. , Office Table 2.5*5 Ft Office Table Product Of Spacewood Executive Office Table With 3 Drawers And One Rack (5 X 2.5 Ft) , Table Length = 120Cm, Width = 60Cm, Height = 79.5Cm Engineered Wood 18-Inch Telescopic Channels, Mini Fixes, Stainless Steel Handles, Hinges, Screws, And Dowels Net Weight 42 Kg 1 Drawer, 1 Closed Compartment , Three Seater Three (3) Seater Chair Stainless Steel Waiting Area Visitor Reception Chair , Visitor Chair Leatherette Weston Visitor Guest Chair Or Study Chair , Visitor Chair S S Material Stainles Steel+ Cushion Visitor Guest Chair Or Study Chair , Ghantagadi High Quaity Non-Toxic Unbreakfable Fiber Material With Strength And Durability +Area : Length – 1230 Mm Width – 924 Mm Depth – 485 Mm +Volume : 320 Litre / 20Cft + Load Carrier Capacity : 210 Kg. + Paint : Yellow & Black Pu Paint Over Two Coat Of Epoxy Primer. , Inverter + Battery Inverter Led Display For Status Of Power Back-Up / Battery Charging Time In Hours And Minute,Inverter With 32 Bit Dsp Processor, Automatic Temperature Control,Battery System :- Single Battery / 12V; Capacity : 900 Va, Rated Power: 756W Maximum Bulb Load - 756 Watt, Capacity – 900 Va; Running Load :- 3 Cfl, 3 Tube Light, 3 Ceiling Fan, 1 Television, 1 Air Cooler , Cup Board Kapat 6.5 Material Mild Steel, Double Door, Multiple Lockers For Personal Use, Compact Design, Non Corrosive,Size 78 X 36 X 19 Inch (H X W X D), No Of Shelves 6. , Cup Board Kapat 5.5 Material Mild Steel, Double Door, Multiple Lockers For Personal Use, Compact Design, Non Corrosive,Size 66 X 36 X 19 Inch (H X W X D), No Of Shelves 5. , Cup Board Kapat 4.5 Material Mild Steel, Double Door, Multiple Lockers For Personal Use, Compact Design, Non Corrosive,Size 66 X 36 X 19 Inch (H X W X D), No Of Shelves 5. , Flood Lightflood Light 50 Watt + Slim + Ac+Dc + Clamp + Mcb + Mcb Box + Wiring + Fitting With 2 Yrs Warrenty , Flood Lightflood Light 30 Watt + Slim + Ac+Dc + Clamp + Mcb + Mcb Box + Wiring + Fitting With 2 Yrs Warrenty , Street Light Street Light 45 Watt + Slim + Ac+Dc + Clamp + Mcb + Mcb Box + Wiring + Fitting With 2 Yrs Warrenty , Street Light Street Light 60 Watt + Slim + Ac+Dc + Clamp + Mcb + Mcb Box + Wiring + Fitting With 2 Yrs Warrenty , Dual Desk In Metal + Ply School Activity Study Desk For Kids - Cartoon Dual Seater Metal + Ply Study Table And Chair Dimensions - 30.5 X 28.5 X 20 (Inches) - For Anganwadi , Educational Mat 0 To 9 Nirvik Puzzle Foam Mat For Kids Interlocking Learning Educational Numbers Floor Mat For Baby Kids Playing (10 Pieces) , Educational Mat A To Z Nirvik Puzzle Foam Mat For Kids Interlocking Learning Educational Alphabet Floor Mat For Baby Kids Playing (26 Pieces) , Educational Pendrive Educational Pendrive For Nusrary + Software + Hd Quality Visual Rhymes + Marathi , Educational Pendrive Educational Pendrive For Nusrary + Software + Hd Quality Visual Rhymes + English , Multi Function Printer Multi-Function Monochrome Laser Printer With Auto Duplex Printing & Network , Roro Water Purifier 15 Ltr 15 Litre Ro + Uv+ Uf + Tds Adjuster Water Purifier+Water Tank + Plumbing + Fitting , Roro Purifier 25 Lph Commercial Uv + Ro Water Purifier Plant/Filter Double Purification With Auto Shut Off And Tds Adjuster 25 Litre Per Hour + Water Tank + Plumbing All + Fitting , Roro Purifier 50 Lph Commercial Uv + Ro Water Purifier Plant/Filter Double Purification With Auto Shut Off And Tds Adjuster 50 Litre Per Hour + Water Tank + Plumbing All + Fitting , Mega Phone Mx Handheld Battery Operated Megaphone With Microphone, Siren Handheld Megaphone Am 21Sd+ Indoor, Outdoor Pa System (120 W) , Mice With Speacker Captcha Bluetooth Speaker Karaoke Portable Wireless 668H/702H/703H , Trolly Speacker 10 10 Inch Portable Trolley Speaker With Bluetooth, Fm, Karaoke & Record Function , Trolly Speacker 15 15 Inch Portable Trolley Speaker With Bluetooth, Fm, Karaoke & Record Function , A 4 Paper A4 Size | 75 Gsm | 500 Sheets | White Paper, 1 Ream | For Laserjet & Inkjet Printer | Fast Drying | Both Side Print | Eco Friendly | Colorlok (Pack Of 1) One Ream , Smart Tv Smart Tv+ Hd + Display Size 32 Inch + Resolution 720 P + Refresh Rate 60 Hertz + Model 21 , Smart Tv Smart Tv+ Hd + Display Size 40 Inch + Resolution 1080 P + Refresh Rate 60 Hertz + Model 21 , Weight Machine Weight Capacity 180Kg, Tempered Glass Material 280Mm*280Mm, Low Power & Overload Indicator , Lcd Display. 4 Strain Gauze Sensor Feet , Auto On/Off , Fully Automatic, 0.1 Kg Graduation. , Basket Ball Kids Baybee Multi Activity Sports Basketball For Kids/Outdoor & Indoor Games For Kids/Adjustable Basketball Set Toys With Ball/Multicolor Toys Kids Basket Ball For Babies (Classic,Multicolor) , Rider Baybee 3 In 1 Baby Horse Rider-Kids Ride On Push Car Toy Car Rider Babies Toy Toddler Baby Toy 1-3 Years Old - Indoors And Outdoors Kids Made In India Suitable For Boys & Girls (Blue) , Slide Small Baybee Foldable Baby Garden Slider For Kids - Plastic Toy Garden Slide For Kids/Toddlers/Indoor/Outdoor/Home/School Preschoolers For Boys And Girls Age Group-1 To 4 Years , Slide Big Baybee Foldable Baby Garden Mega Sliders For Kids - Plastic Garden Slide For Kids/Baby Indoor Outdoor Games | Baby Sliders For Kids Toys | Garden Slide For Kids 1-5 Years Boys Girls (Mega Slide) , Swing Garden & School Toy Swing For Children Babies Indoor Outdoor , See Saw Plastic Playtool See Saw Rocker With Metal Backrest , See Saw Big See Saw Rocker For Kids - Plastic See Saw Jumbo Rocker For Indoors And Outdoors - Perfect Toy For Boys And Girls Of Age 1-8 Years - Dimesnsions: 118 X 32 X 45 Cm , Tricycle Tricycle For Kids - Duke Tri-Cycle - With Music, Sipper And Bell For Boys And Girls (1 Year - 4 Years) , Ghoda 1 Baby 2 In 1 Appu Elephant King Rider N Rocker For Kids 1-5 Years Birthday Gift For Kids/Boys/Girls , Baby Chair Prima Baby Plastic Chair 120 Strong Durable And Comfortable With Backrest For | Kids | Study | Play For Home/School/Dining For 2 To 6 Years Age , Baby Chair + Tray Baby Chair, With Tray Strong And Durable Plastic Chair For Kids/Plastic School Study Chair/Feeding Chair For Kids,Portable High Chair For Kids Upto 35 Kgs , Baby Chair 1 To 3 Small Kids Chair For 1-3 Years Toddlers || Strong & Durable Chair For Toddlers || Virgin Material Baby Chairs || Portable Baby Chair For 1 Year+ || Chair For Toddler Kids , Baby Chair 3 To 6 Small Kids Chair For 1-3 Years Toddlers || Strong & Durable Chair For Toddlers || Virgin Material Baby Chairs || Portable Baby Chair For 1 Year+ || Chair For Toddler Kids , Book Self Wooden Kids Wooden Bookshelf Magazine Holder For School/Office/Reception Living Room Furniture : Bookcases, Multicolour, Medium , Trompoline Kids Trampoline 38-Inch Folding Trampoline With Safety Padded Cover For Play Mini Rebounder Suitable For Indoor And Outdoor Jump Sport , Wooden Frame Wooden Puzzle A To Zfor 2-6 Years, Multicolour , Wooden Frame Wooden Puzzle Numbersfor 2-6 Years, Multicolour , A To Z Mat Mat + 1-1 26 Pcs , A To Z Mat Mat + 6-6 26 Pcs , 0 To 9 Mat Numeric Mat 10 Pcs Set , Mat Mat For Outdoor + Indoor Floring & Safety 3*3 , Mat Mat For Outdoor + Indoor Floring & Safety 2*2 , Hardbound Books All Types Of Hardbound Small Pocket Book , Hardbound Book All In One Book For 1 To 6 Yrs , Mrf Cricket Bat Willow Cricket Bat Meant For Playing By 11 - 15+ Yrs Boys And Girls Comfortable Rubber Grip. Lightweight Design And Full Size. , Pepsi Rubber Ball Dog Practice Ball Comes In Multicolours Material: Rubber , Plastic Ballgood Quality Material , Multicolor , Smiley Ball Smiley Stress Free Balls Perfect For In & Around The Pool, At The Beach, And Any Playground! Soft Ball , Squeeze Ball , Carrom Board Large Comes With 2 Inch Border Offering Excellent Rebound. 2X Ply Thickness(8Mm) Leading To Sturdy, Flat Surface And Excellent Life. Perfect Carromboard For Serious Enthusiasts And Semi Professionals Comes With 2 Inch Border Offering Excellent Rebound. 2X Ply Thickness(8Mm) Leading To Sturdy, Flat Surface And Excellent Life. Perfect Carromboard For Serious Enthusiasts And Semi Professionals , Carrom Board Small Comes With 2 Inch Border Offering Excellent Rebound. 2X Ply Thickness(8Mm) Leading To Sturdy, Flat Surface And Excellent Life. Perfect Carromboard For Serious Enthusiasts And Semi Professionals Comes With 2 Inch Border Offering Excellent Rebound. 2X Ply Thickness(8Mm) Leading To Sturdy, Flat Surface And Excellent Life. Perfect Carromboard For Serious Enthusiasts And Semi Professionals , Chess Board Plastic Large Material Type(S) ?Plastic, 13 Years And Up, Made From Using Premium Unbreakable Quality. Non Tearable & Washable. International Standard Chess Pieces. , Chess Board Wooden Chess And Chess Boards Are Made Of Wood With Polished Surfaces And Are Very Smooth With Strong Magnetism Embedded. Chess Table With Clear Pattern On The Surface, Folding The Wooden Board Anti-Scratching 32 Chess Pieces , Dhol Material: Body: Steel, Face: Pvc Sheet,Color: Silver Size (L X B X H): 48 Cm X 48 Cm X 16.5 Cm , Dumbell Pair Dumbbells For Pt 1 Set,Made Of Wooden,Size:- Standard Size , Lezim Colour Red, Green,Material Wood, Steel Nuts,Model Name Laz 12 , White Board 3*4 Colour White,Mounting Type Wall Mount,Material Non-Magnetic,Frame Material Aluminium , Notice Board3*4 Material Aluminium,Mounting Type Wall Mount, Green And Red Color , Notice Board 2*3 Material Aluminium,Mounting Type Wall Mount, Green And Red Color , Chart- Chart Is Educational Helps To Introduce The Young Learners To A Variety Of Everyday Conceptsthe Charts Have Beautiful, Vibrant Images With Accurate Alphabet Labels To Help Kids Absorb Information Faster And Make Learning Fun And Interactive , Wooden Board Material Wooden , Multicolor, Toy Is Made Of Solid Wood, Its Durable, Safe And Eco-Friendly , Fruit Set Plastic Material Plastic , Multicolor , Durable And Safe , Vegetable Set Plastic Material Plastic , Multicolor , Durable And Safe , Lezim Colour Red, Green,Material Steel Nuts,Model Name Laz 12 , Cricket Set Bigall Cricket Set + Bat + Stump + Bells +Bag + Glowes + Pad + Guard , Plastic Cricket Set Heavy Bat + Ball + Stump + Ball + Heavy Quality , Meli Dust Powder 30 Kg Bag , Tcl Powder Bleaching Powder 30 Kg Bag , Mobile Toilet Indian Frp Movable Toilet , Colour Cutomised, Shape Square, Durable Material,Indian Toilet,With Water Tank , Mobile Urinal Frp Movable Urinal, Colour Cutomised, Shape Square, Durable Material, Male Urinal, With Water Tank , Hand Wash Station Manual Easy To Use, Can Be Used At Public Or At School, Strong Metal Frame,With Water Tank,Manualy Operated , Hand Wash Station Foot Operated Easy To Use, Can Be Used At Public Or At School, Strong Metal Frame,With Water Tank,Foot Operated , Cctvcontains Dvr, Hard Disk, Cameras Dome Or Bullet, 2.4Mp Camera, Wired, Electric, Outdoor Or Indoor Use , Dust Bin Plastic 12 Liter With Lid , Dust Bin Plastic 12 Liter Without Lid , Dust Bin Plastic Paddle Bin Dust Bin 1007 , Dust Bin Plastic Paddle Bin Dust Bin 1008 , Dust Bin Plastic Paddle Bin Dust Bin 1009
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
30.
Rural Development #10780316 Price Bid
Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Nighoje Tal Khed Dist Pune- 1 Supplying and erecting modulartype switch6A / 10A 2 Supplying and erecting Street light bracket for erection ofSingle fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length 3 Providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16-3-2) 4 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation.(weight 101 kg.) as per specification no.OH-PL/STP 5 Supplying and erecting Street light bracket made from 25mm. dia ‘B’class G.I. Pipe, 0.6m. in 6 Supplying and erectingLED street light fitting suitable for 36w TO 40w LED Street Light, including lamp, with PF > 0.95 class IP 65 . 7 Supplying and erecting LED street light fitting suitable for 50W lamp, including lamp, with PF > 0.95 class IP 65. 8 Supplying and erecting LED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65. 9 Supplying and erectingLED street light fitting suitable for 90 w LED Street Light, including lamp, with PF > 0.95 class IP 65. 10 Supplying and erecting LED Flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 11 Supplying and erecting LED Flood light fitting of 150W, including lamp, with PF > 0.95,class IP 65 12 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 13 Providing rental basis Hydraulic Bucket Vehicle of Hight 13 Mtr. And Weight Capacity 200 kg. with Driver, Oprator and Disel etc. For Per Day basis 14 Labour Chrages for LED fitting on Street light or MS light pole. 15 Dismentaling Charges -LED street light of pole. 16 1.25 mm CRCA sheet metal enclosures box for Timmer and MCB 17 Supplying PVC insulated PVC round sheathed 1.5 sq.mm 18 Supplying & Laying armoured cable 4C X 6 Sq.mm. 19 Supplying & Laying armoured cable 4C X10 sq mm 20 Supplying & Layingarmoured cable 2C X 10 sq mm 21 Supplying & Layingarmoured cable 4C X 16 sq mm 22 Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) 5-3-3 23 Supplying, erecting & marking DPMCB 6 A to 32 A Bseries (for lighting) 5-3-7 24 Supplying and erecting Programmable Digital AlmanacTimer Microcontroller based with real time clock to operate on derived switching “ON” & switching “OFF” street light as per daily sunset and sunrise respectively 25 Supplying & erecting crimping type Aluminium lugs for cable upto 16 sq mm complete 26 Supplying & erecting crimping type Coper lugs for cable upto 1.5 To 6sq mm complete… 27 Supplying and erecting two pole power contactor 250V 32A for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3 28 Supplying & erecting mains with2x1.5 sq.mm F.R copperPVC insulated wire laid in provided conduit/trunking/inside pole. 29 Supplying and erecting mains with ISI mark WP2 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire No. 8 SWG 1-4-3 30 Supplying and erecting mains with ISI mark WP2 x 2.5 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 31 Supplying and erecting mains with ISI mark WP2 x 10.00 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 32 25 Amp, 32 Amp Three Phase L/T Contactor 33 2.5 Sq. mm Multistand Copper Wire 34 Insulation Tape 35 Water Proof Tape 36 Street Light Pole Box FRP 37 Cement Street Light Pole Clamp 38 M.S. Street Light Pole Clamp 39 LED Street light Arm bend pipe 40 Small Size FRP box for MCB 41 Big Size FRP box for MCB 42 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes(DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 43 Servicing And Primary Maintenance For Street Light Pole. 44 Light Poles painting in Silver Colour 45 26W LED Light To 100W LED Light Repairing 46 Old Pole Shifting, Rework and Foundation Work per Pole etc. 47 Supply &Fixing of Shakle Hardware with Nut Bolt 48 Supply and Installation of Mini Feeder Pillar with Stand 49 RCC Road Cheasling Charges with Tractor Breaker (1 Hours) 50 Tree Triming for Overhead Line 51 Tree Triming for Overhead Line 52 7-1-33 Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor 53 7-1-31 Supplying, erecting & terminating XLPE armoured cable 4 core 35 sq. mm aluminium conductor 54 7-1-34Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm aluminium conductor 55 7-1-35 Supplying, erecting & terminating XLPE armoured cable 4 core 120 sq. mm aluminium conductor 56 5-3-5 Supplying, erecting & marking SPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 57 5-3-9 Supplying, erecting & marking DPMCB 40A to 63A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/ MCB 58 5-3-29Supplying, fixing and commissioning MCB type change over switch 2 pole, 63 A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS 59 5-3-32 Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS 60 7-9-4 Supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. CB-CL/CU 61 7-9-5 Supplying & erecting crimping type copper lugs for cable 70 sq. mm. complete as per specification no. CB-CL/CU 62 7-9-7 Supplying & erecting crimping type copper lugs for cable 120 sq.mm. complete as per specification no. CB-CL/CU 63 4-4-5 Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials. 64 Cable Joint Kit for armoured cable 20 upto 120Sq. MM Cable 65 GI Tar for service wire support with bobine. 66 Kit kat Type fuse 16A 32A 63A 120A 67 Taparia Tester 68 Spaner Set 69 Control Panel HRC Fuse 70 Supplying And Erecting Transformer Fidder Piller 71 5-2-19 Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation. 72 Bag filtter for 250/500/1000 LPH RO plant 73 Small cartridge filter 74 Big size cartridge filter 75 Coin mechanisum unit 76 Aster RO ATM unit 77 MECH-101 RO membrane cleaning chemical liquit -5 ltr 78 Supplying and erecting MS Pole Bracket 1100mm long (65-65-6) 79 Supplying and erecting aluminium standed cunductors 7/3.10 mm (Ant.) 145 Kg/Km) 80 Supplying and erecting ACSR aluminium standed cunductors 6/1-2.59mm Kg/Km 81 Supplying and erecting GI stay set for Pole including loops insulators height with achor plate 300x300x6 mm GI Wire 7/8 SWG 82 Supplying and erecting RSJ (Girder) Pole 125 x 70 mm (13.3Kg/m) 83 Supplying and erecting shackle type LT medium insulator 75x115 mm dia. With GI streep Nut Bolts etc 84 Supplying and erecting aluminium bobbin With GI streep Nut Bolts etc 85 Providing earthing with galvanized iron earth palte 60 x 60 x 0.6 cm with all materials 86 sand and Carban
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
31.
Housing Urban and Rular Development #10778154 Price Bid
Tender For Construction Of 33/11 Kv Sub-Station In Sector 146, Noida. - S/E of Terminal Gantry Structure of R.S. Joist - 175x85 mm. 19.5 Kg/Mtr. 6.1 Mtr. above the ground and 1:3:6 cement concrete foundation mounted on a stone pad of 300x300x75 mm. with 2 nos channel 175x85 mm suitable for Disc & Pin Insulator Including earth excavation back filling making plinth of required height and with required fabrication as per drawing. complete in all respects as per direction of E/I.(AOR) 2 S/E of 33 KV, 1250A double break Line Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/m. and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects . Make: Jaipuria/Rama/UPPCL approved. as per direction of the E/I. (AOR) 3 Supply, Errection, Testing & Commissioningof 33 KV Outdoor VCB with required str, 1250A, 1500MVA, 25KA, Motorized 750MVA/1250Amp/ with transformer control & relay pannel includingCT, PT with structure. complete in all respectsMake: Crompton/ABB/Schneider as per specification and direction of E/I. (AOR) 4 S/E of Busbar Gantry Structure of 105 Lbs/Yard Rail pole 6.50 M long 5.2 Mtr. above the ground level and 1.30 Mtr. Below in 1:3:6 cement concrete foundation mounted on a stone pad of 300x300x75 mm. With M.S. angle 100x100x8mm (12.1Kg/M) mm suitable for Disc insulator including earth excavation, back filling, making plinth of required height and with required fabrication as per drawing complete in all respects as per direction of E/I.(AOR) 5 S/E of 33 KV, 1250A Bus Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. Thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/M and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects Make: Jaipuria/Rama as per direction of the E/I. (AOR) 6 S/F of 33 KV fuse set out door type of Relco/Rama make complete including structure as per drawing. Complete in all respects.(AOR) 7 S/E of 33 KV Lightning Arrestors with Structure made of M.S. Channel 125x65 mm. 13.1Kg/M top of M.S. Angle 50x50x6 mm. 4.5 Kg/M Lightning Arrestors/Post Insulator are to be mounted on M.S. Plate of 200x150x8 mm. Height of structure is to be 3.5 Mtr. above ground and 1 Mtr. below ground on a 75 mm. thick cement concrete pad with 1:4:8 cement concrete foundation, making plinth of required height including all fabrication as per drawing complete in all respectsMake: Elpro/Oblum/W/Sas per direction of E/I. (AOR) 8 Supply & fixing of 33 KV with 11KV 4 Nos SetB&S type strain Disc insulators 120KN E&M strength. as per drawing complete in all respects Make : Jaishree/BHEL/WS/RR as per direction of E/I.(AOR) 9 Supply & fixing of 33 KV tension fitting suitable for panther conductor and 120KN E&M 11KV disc insulator set of 4 complete in all respects as per direction of E/I. (AOR) 10 Construction of 33 KVtransformer plinth as per drawing. with all material, labour and T&P etc. required for proper completion of the work as per specifications of UPPCLas per direction of E/I.(AOR) 11 Providing and fixing of G.I Chain link fabric fencing of required width size 50x50mm including strenthening with 2mm dia wire or nuts,bolts and washers as required complete as per the direction of the Enginner-in- charge.made of G.I wire of dia 4mm PVC Coated to achive outer dia not less 5mm in required colour and shade.complete in all respect as per ditection of E/I(AOR). 12 Construction of boundary wall in brick work with cement mortar 1:6 (1 Cement : 6 Coarse Sand) for chain link including plaster in cement mortar 1:4 (1 Cement : 4 Coarse Sand) and finishing with water proofing cement paint complete as per attached drawing & complete in all respects as per direction of E/I.(AOR) 13 S/Fixing of 33 KV Post insulator 2x22KV of approved quality and make with all necessary material required for proper fixing including structure made of 125x65mm MS Channel (2.5Mtr above ground of 1 mtr below with ground with grouting 1:3:6 cement concrete including all labour, material, T&P etc. required for proper completion of the work. as per drawing. complete in all respectsMake: Jai shree / BHELas per direction of E/I (AOR) 14 1 nos1250A, VCB of (350MVA) 18.4 KA reputring capacity at 11 KV rated,totally enclosed, air insulated metal card housing floor mounting horizontal isolotion vermin proof fully interlock horizontal draqout type having isolation features and control devices complete with following. (AOR) 15 8 nos single phase double core current transformer 300/5.5/5 Amp epoxy cast resin isulated class of isulation E as per SLD. 16 core 1-15 VAburden class 1.0 for meeting 17 core 1-15 VAburden class 5P10 for protection 18 one no.numerical microprossor based three phase over current (IDMT element )with earth fault relay with instantaeous elements. 19 1 no Anti Pumping device 20 1 no circuit breaker control switch for electrical (T/N/C) 21 1 no limit switch for test & service 22 1 no Ammeter (0-3000Amp & 0-5-Amp) with selector switch (96mm Square. 23 1 no Electronic type digital energy analyser having 30 Days memory and parameters of KW-KWH,Power factor, frequency etcsuitablefor BMS compatible with all accessories. 24 1 no tri vector meter 25 1 set of following indicatinglamps 26 Red,Yellow,& Blue for Phase indication 27 Amber for trip indication 28 Redon Green off 29 Spring charge indication 30 Auto trip indication 31 1 No Hooter with hooter acceptance and reset push button 32 1 No master trip relay (Eletromechanical type) 33 1 set of fuses ferrules wiring etc as required 34 Note: All Spare contact of breakers or any other equipment inside the breaker shall bewired upto the outgoing terminal strip with appropriate terrules/coding . The terminal strip rating shall be suitable for coneccting two wires of 2.5 sqmm subjected to providing minimum size suitable for 4/6 sqmm. (Make- ABB, Crompton, Schnieder, Seimens) 35 11KV H.T Panel describe as above 36 Construction of control cable trench of required size 0.30x0.45 Mtr. bricks class designated-100 work including plastering etc. and covered with R.C.C. Slab (0.50x0.60 M) size complete with all material, labour and T&P etc. required for proper completion of work. complete in all respects. As per direction of E/I.(AOR) 37 S/Filling of 20 mm. stone grit in yard of size26x36mtr75 mm. thick complete in all respects. (AOR) 38 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 39 Supply & laying of earth mat in the switch yard of the Sub-Station for all Electrical Equipments and structure by laying of M.S. Round bar of 32 mm. dia. in 750 mm. deep trenches and earth electrode 3.0 M. long of M.S. round bar 32 mm. dia 0.5 M below ground level. The work include welding/bending/flooring of M.S. round bar and connection all steel structure in switch yard with earth mat by means of M.S. Strip of size 50x6 mm. including all labour, materials, T&P etc. required for proper completion of the work as per details specification of UPPCL Complete in all respects as per direction of E/I. (AOR) 40 Painting of (Complete sub-station) Terminal Gantry, Lighting arrestor, Busbar Gantry, Line Isolator & Bus Isolator Structures, Post insulator, Fencing, Poles and other structure complete with two coats of Al. paint over red oxide. (AOR) 41 S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I.(AOR) 42 Supply and laying of Control Cable for metering as per direction of E/I. (Gloster/Grandley/Havells/ Polycab/ Diacab make) (AOR) 43 (a) 2.5 Sq. mm. 2 Core Copper 44 (b) 2.5 Sq. mm. 4 Core Copper 45 (c) 2.5 Sq. mm. 10 Core Copper 46 Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-48 47 S/E of 125x65 mm. MS Channel (13.10 Kg/M) 1.5 M long fixing in control room for OCB/VCB pannel complete in all respects as per direction of E/I.(AOR) 48 Supply/Fixing of MS ladder of size 5 mtr long and 0.4m width with MS angle 40x40x6mm incl painting etc . complete in all respect as per direction of E/I.(AOR) 49 Supply, Installation, Commissioning & Testing of Battery charger 24V 24V/40Amp float cum Boost battery charger with dropping diodes suitable for I/P 230V±10%, 1 Phase, 50Hz Type FCBC as per PVVNL Specification, maximum continuous output ratings (outpur voltage in float mode 25.80 Volts and in Boost mode upto 33.0 Volts), output current 40A, Plus trickle charging currentof battery floatmode 20A(Max), Boostmode 20A Load terminal, 20A, Battery terminal 20A, Starting rate 10A upto 2.35 V per cell, Finishing rate 10 Aupto 2.75 V Per cell, Output ripple 1% PP at full load and 25.8V DC, output regulation (floatmode) ±1%for ±10% supply voltage fluctuation and ±10% to 100% load variation, Automatic/manual mode of operation, Automatic and manual terminal charging, control configuration 1-phasefull wave controlled, thyristor bridge feed through 1-phase transformer and controlled by constant current/protential controller with load liminting feature and integrated non compartmentalized DCDB with 01 No 60A MCCB incomer, 5 Nos 16AMCB, sheet thickness 2mm, protection as per detail specification enclosed. 50 IS: 13947) IP-42/ maximum Permissible input volage ±10% of 230V AC, Electronic protection with auto reset against short circuit and overload ,DC over voltage short circuit at charger output terminals, thyristor by fuseing with protection against over charging, efficiency of rectified >65% at rated load, Power factor 0.7 lag at D.C. Current 230V Input with ANC cooling typeand Class F type insulation.For Battery : 240V/200AH Tubular type Battery Bank consisting 12 Cells of each 2V/200 AH dry & uncharged along with wooden stand & accessories (AOR) 51 S/Installation, testing & commissioning of out door type 10 MVA with on load tap changer Power Transformer as per ISI specificationincluding loading, unloading, local carriage & erection of the same on existing plinth & making all necessary connection etc. Complete in all respects Make: Crompton/ Alstom/BHEL/ABB/Schneider as per direction of E/I. (E-12) or approved GTP from UPPCL/PVVNL cable termination box with disconnecting facility for 33 KV XLPE cable at 33 KV side.cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side.On load tap changer +/- 7.5@ 2.5% Bi directional roller, Conservator with drain valve, Earthing terminals, Double diaphragm explosion vent, Radiator with top & bottom shut off valve, First filling of oil including make up fill, Silica gel breather with oil seal, Rating and diagram plate, Air Release plug, Buchholz relay with shut off valve, Winding temperature indicator (WTI), Oil Temperature indicator (OTI), Megenatic oil level guage, Pressure relief device, Marshalling box .Aproved By CEO. (AOR) 52 S/Laying of Aluminium conductor PVC insulated armoured, served, sheathed cable 1100 V grade at a depth of 75 cm. below ground level over a cushion of 75mm. Below ground level over a cushion of 75mm. thick snad alround and protected with burnt bicks on sides and on top. on surface the cable run shall be fixed on MS clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respected. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. P.S. No. 501 (Gloster/Grandly/Polycab/ Havells/Diacab. make) 53 a) 50 Sq.mm. 3½ Core 54 b) 25 Sq.mm. 3½ Core 55 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. P.S. No. 1131 56 Supply and fixing of Lugs(socket) forCable P.S. No. 504 57 i) 25 Sq.mm. 58 ii) 50 Sq.mm. 59 iii) 120 Sq.mm. 60 iv) 185 Sq.mm. 61 supply and burying earth electrode for lighting conductor of 600mmx600mmx6.0mm G.I. Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. Pipe for watering funnel, 30cm square C.I frame with hinged cover masonry housing alternate layrs of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects.P.S. No. 706 62 S/F of brass nickle plated compression gland for PVC isulated & armoured served sheathed, underground cable incl. rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of E/I P.S. No 503 63 (a) Size 25 mmx 3.5 core 64 (b) Size 16 mmx4 core 65 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (A) 66 S/B of 40 mm dia x4.5 meters long GI pipe vertically of earthing having 12 mm dia. Holes spaced 75 mm apart drilled up to 2 meter from the bottom complete with earthing lead of no. 6 to 8 SWG GI wire in GI pipe up to appron) and from appron to switch board (The cost of GI wire and pipe will be extra) upto switch board, 30 cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layes of charcoal / coke and salt at least 150mm thick alround etc. as per directions of engineer-in-charge complete in all respects as per drawing as per PS No. 701 67 Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing ead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (B) 68 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 69 S/E of overhead line with ACSR(Painther/Dog) Conductor on pole/service bracket including binding etc. complete in all respects PS No 627 70 S/F of fire bucket, round bottom made of GI sheet 9-11 liters capacity duly painted as per fire brigade design, supported on hanging bracket, chained & locked initially filled with fine river sand, water as per direction of E/I. P.S. No. 1133 71 S/F of shock treatment chart (Prescribed under I.E. Rules) duly framed with glass & supported from back with hard board or soft board with supply of all material labour and T&P for proper completion of work. P.S. No. 1134 72 S/L of 1800x900x12 mm. thick chequered rubber matting of testing quality. P.S. No. 1136 73 Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 74 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :Make : Raychem/ Denson/ :DSR 2018 75 120 Sq.mm.I.No. 10.5.2 76 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required :Make : Raychem/ Denson. 77 120 Sq.mm. UPERC Pg-27 78 185 Sq.mm UPERC Pg-29 79 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.DSR-2018/Item No. 14.13.2 80 80mm dia 14.13.2 81 100mm dia 14.13.3 82 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 83 Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. DSR-2018/I.No. 13.23 84 Supply and fixing Clamps, bolts, nuts etc.complete in all respects (DSR-2018/I.No. 2924) 85 Supply of following type high conductivity aluminum strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. Complete in all respects Make: Gloster/ /Universal/ Polycab/ Havells/ Diacab .as per direction of E/I. 86 i) 185 Sq.mm. 3 Core UPREC 2019 P-41 87 ii) 120 Sq.mm. 3 CoreUPREC 2019 P-41 88 S/F of 11 KV pin 12 long with insulator of Jai Shree/HBHEL on cross arm fixed on HT pole including all T/P etc UPERC P-39 Annexure-16 89 S/F of 11 KV TPMO Relco/Rama make 9 nos insulator of Jai shree/BHEL make complete in all respects as per direction of E/I UPERC P-48 90 S/E Testing & Commissioning of 63 KVA Al. wound outdoor type Transformer as per ISS. Complete in all respects Make : P.M./Kanohar/LD Power/Paramix as per direction of E/I (UPERC 2019) P-51 91 Supply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 92 BOQ-BSupply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 93 Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 94 Supply of required clamp made of MS Nut and bolt etc. as per direction of E/I complete in all respects UPERC P-39 95 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 96 Supply of 300 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 33 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respectsas per direction of E/I. Make: Gloster/ /Universal/ Polycab/ Havells/ Diacab . (UPERC P-47) 97 S/F of jointing of 300 sq. mm out door type type 33 KV jointing kit heat Shrinkable type for 33 KV Cable including cost of all material, labour, T&P etc. for proper completion Make : Raychem/ Denson. as per direction of E/I. (UPERC P-47) 98 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 99 S/Making of Straight through joint suitable for 300 sqmm x 3 core 33KV armoured cable as per ISS & Complete in all respects Make: Raychem, Denson. As per direction of E/I. (UPERC P-47) 100 S/E of over head line with ACSR Panther Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 101 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) 102 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) 103 S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 300 Sqmm 104 Painting of the electric pole with 2 coat of AI paint over red oxide primer complete in all respects As per PS No. 634 105 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 106 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 107 S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 108 Numbering of poles with combination of yellow and black colour paint etc complete in all recpects as per direction of E/I (AOR) 109 S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (creator poly extrusion/duraline/rex/times/ naranderplast/pioneer make). (AOR) 110 Providing and laying of200mm dia 6mmthickness through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) 111 S/E of 33 KV, 1250A double break Line Isolator with Structure made of 125x65 mm. 13.1 Kg/M Channel at a height of 2.5 Mtr. above ground and 1 Mtr. below ground on a cement concrete pad of 75 mm. thick with 1:3:6 cement concrete foundation including excavation back filling, making plinth of required height & with required fabrication for bracing of M.S. Flat 50x6 mm. 2.4 Kg/m. and top of M.S. Angle 75x75x8 mm., 8.9 Kg/M as per drawing (for structure) Complete in all respects . Make: Jaipuria/Rama. as per direction of the E/I. (AOR) 112 Laying of One number XLPE power cable of 33KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N.8.7.2/P34) Above 120 Sqmm and upto 400 Sqmm 113 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..(DSR elect 2018 Item.N.7.9/P30) 114 Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required..(DSR Electrical 2018/Item 13.23 Page 50) 115 Providing and fixing precast reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) kilometre stone as per standard design, including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work, concrete in foundation,ainting and lettering etc. which shall be paid for separately. 35x111x25 cm size (AOR) 116 Finishing with epoxy paint(two coat or more coats) at all location prepared and applied as per manufacturers specifications incuding appropriate priming coat, preparation of surface etc. Complete on concrete work (AOR) 117 Lettering with black japan paint of approved brand and manufacturer (AOR) 118 Providing and laying in position cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.7 P-48 119 Providing and laying in position cement concrete1:3:6 (1 cement : 3 coarse sand (zone-III) :6 graded stone aggregate 40 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.9 P-48 120 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.(AOR) 121 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion..(AOR) 122 BOQ-CWiring points for light with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire,GP Box piano type switch and ceiling rose/angle/batten holder3mm thick phenolic laminated backelite sheet etc.Complete in all respects as per direction including mathcing colour wash.P.S. No. 138C 123 Wiring points for Fan/fresh air fan (light duty exhaust fan) with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire,GP Box piano type switch and ceiling rose3mm thick backelite sheet etc.Complete in all respects as per direction including mathcing colour wash.P.S. No. 140C 124 Wiring points for Plug with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cable inPVC conduit with 1.5 FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn in side the conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting complete with 14SWG Copper earth continuity wire, piano type switch and socket etc.Complete in all respects as per direction including mathcing colour wash.P.S. No. 141C 125 Supply and fixing of recess/surface mounting round 24 Watt to 32 Watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink, diffuser/ Reflector and driver set completed in all respects. P.S No. 1405 Cat AAA 126 S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve. PS No. 1002 Cat A 127 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (A) 128 Supply and fixing of power plug with 15A / 250 V flush type switch and 5 pin 15 A / 250V flush type socket in suitable M.S. box of 175 mm x 100 mm x 50 mm size with Bakelite sheet cover 3 mm. thick fixed with brass machine screws and cup washer. P.S. No. 1139 129 Supply and wiring of submain with two number 6 sqmm FRLSH PVC insulated 1100V grade multistrand single core copper conductor cable in 25mm dia heavy duty (2mm thick) PVC Conduitl with one number 4 sqmm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. as per PS No. 217 (C) 130 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. PS No. 641(Make - Bajaj/ Transrail /Volmont/ NERI) 131 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. P.S. No. 1421 Cat. AAA 132 Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Grandley/Gloster/Havells, Polycab, Diacab. make) P.S 501 133 a. 25 sq. mm 3.5 core 134 b. 35 sq. mm 3.5 core(PS No. 501(k) 135 S/F of sintex type junction box model no. IIGSJB 2817 of size 240x130x110mm with hinges and locking arrangment & MS clamp of 50x6mm flat, complete in all respects including 2 no. G.I pipe 1.5 dia having 1.0 meter length each and chuck nut for cable connection etc. as per direction of E/I. (AOR) 136 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS. No. 807 e (ii) 25 A TPN 137 S/F surface/flush mounting 6 ways TPN distribution board without MCB complete in all respects and as directed at site. PS No.1027 Cat A 138 S/F of hexagonal Round GP fan box with hexagonal side of approx. 80mm in lenth fabricated from 16SWG MS Sheet incorporating 10mm dia M S round bar duly duly bent for supporting fan hanger duly painted with red oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all materials, labour, T&P etc. for proper completion of work PS No. 1149 139 S/F of fan regulator dimmer 300/400W ISI mark on the existing switch board including making connection T&P etc. for proper completion of work to the satisfaction of Engineer of work. PS No. 1203 140 S/F of Palm or pin type tin plated copper cable socket (lug) to the cable leads, insulating with tap and making connection etc. complete in all respects as per direction of E/I. (PS No. 504 (e)25 sq.mm 141 f) 35 sq. mm 142 S&F of 63 Amp. 4 pole MCB(10 KA) C Curve as per PS No. 1020 (A) Cat-A 143 Supply and fixing of following size heavy duty industrial type Exhaust fan with louvered shuttersof approved make complete with wire guard mesh, mounting sings frame bracket etc. but without regulator suitable for use on 230/240V 50Hz single phase AC supply and conforming to IS: 2312-1967 with update amended (900 RPM) (Havells single phase Model-300mm)300mm dia (AOR) 144 Supply and Fixing of Ceiling fan 1200 mm dia ISI marked Make-Baja, Crompton, Havells or equivalent make.(AOR) 145 BOQ-DS/F of Steel Tubular Pole 11 M long designated 410-SP-56 in 1:3:6 Cement, Concrete graded stone aggregate of 40 mm. Nominal size & foundation including excavation back filling etc. complete in all respects as per direction of UPERC P-54 146 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 147 Supply of Top MS Channel 100x50x2240mm as per design complete in all respects UPERC P-39 148 Supply of required clamp made of MS Nut and bolt etc. as per direction of E/I complete in all respects UPERC P-39 149 Supply of following type high conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. (Gloster/Universal/Havells, Polycab, Diacab.make)(UPERC 2019 Pg-28) 150 i) 185 Sq.mm. 3 Core E-48 151 Laying of One number PVC insulated and PVC sheathed/ XLPE power cable of 11KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N.8.3.2/P31) Above 120 Sqmm and upto 400 Sqmm 152 S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) uperc Pg-29 153 185 Sq.mm. 154 S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE-100 grade as per IS code 4984 with excavation at depth of 1.20 Mtr. Below ground level i/c the cost of cutting of pipes for making upto length and making joints complete all respects asper direction of E/I (Crator Poly extrusion/Duraline/Rex/time/narander plast/Poineer make) (AOR) 155 Providing and laying of MS Pipe of 200mm dia 6mmthickness as per IS 3589 grade FE 410 through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) 156 S/Making of Straight through joint suitable for 185 sq.mm x 3 core 11 KV armoured cable as per ISS& complete as per the direction and satisfaction ofE/I(Raychem, Denson.Make) UPERC 2019 Pg-29 157 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 158 Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. DSR 2018 13.4 159 S/F of 11 KV pin 12 long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc UPERC Pg-39 160 S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 185 Sqmm 161 Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 162 Numbering of poles with combination of yellow and black colour paint etc. complete in all respects as per direction of E/I. (AOR) 163 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 164 Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 165 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required..(DSR elect 2018 Item.N.7.9/P30) 166 S/E of over head line with ACSR Dog Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 167 S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 168 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50mm, inner pipe 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra.) ps 725(A) 169 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) 170 Providing and laying in position cement concrete1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.7 P-48 171 Providing and laying in position cement concrete1:3:6 (1 cement : 3 coarse sand (zone-III) :6 graded stone aggregate 40 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requriedDSR2018/14.9 P-48 172 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.(AOR) 173 Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion..(AOR) 174 Finishing with epoxy paint(two coat or more coats) at all location prepared and applied as per manufacturers specifications incuding appropriate priming coat, preparation of surface etc. Complete on concrete work (AOR) 175 Lettering with black japan paint of approved brand and manufacturer (AOR) 176 Providing and fixing precast reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) kilometre stone as per standard design, including finishing smooth in 1:3 cement mortar (1 cement : 3 fine sand) but excluding the cost of earth work, concrete in foundation,ainting and lettering etc. which shall be paid for separately. 35x111x25 cm size (AOR) 177 Operation of 33/11 KV Sub-Station round the clock in 3 shifts of 8 hours each by a team comprising of one electrician, skilled operator (having minimum qualification of ITI (Electrician grade) and one unskilled helper in each shift for operation of S/S equipments including maintenance of 11 KV incoming and outgoing Switchgear panels, 33 KV Switchgear pannels, battery and battery charger, 33/11 KV Transformer with control pannels, HT/LT Cable/Lines along with all associated equipments installed at 33/11 KV Sub-Station compus, (Contractor may deploy required man power, as and when required for attending breakdown within minimum time as detailed in Tech. Specification and distribution code) and maintain the required records as per U.P.P.C.L. (AOR) 178 SUBHEAD-I (Equipments H T Panels Transformers and Main L T Panel, capacitor Panel 11 KV RMU Panel (3 Way RMU) Design manufacture testing at works supply, installation testing & commissioning of 3 panel Board 11KV, Indoor tree standing, floor mounting totally enclosed mela clad VCB insulated comprising of 1 Nos 11KV isolater load break switch and 2 Nos Vaccum circuit breaker as outgoing enclosed in robotically laser weided non-extensible type stainless steel SF6 VCB enclosre with SelfPowered relay (IDMTL O/C +E/F) as HT switchgear including suitable transformer protection relays, metering, indicators push buttons, copper busbars, etc as per the requirement complete as required The fault with stand capacity shall beminimum 20KA for 1 second including four cable entries for two incoming cable and two outgoning cable glands and lugs suitable for 2x 240/185 sqmm XLPE armoure cable (Make- ABB, Crompton, Schnieder, Seimens) 179 Incomer shall be provided with Incomer shall be provided with integral Earthing Switch with making switch Live Cable Indicating LEDs energized thru Capacitive Voltage Deviders Transparent Viewing window for verification of Earthing Right Angle terminal protectors / Boots Electrical & mechanical indications as required Outgoing feeders: Two nos. Vaccum circuit breakers with the following SF-6 insulated 630A Circuit Breaker integral Earthing Switch with making switch Emergency Trip Push Button, Electrical & mechanical indications as required Shunt Trip coil for external trip signal Live Cable Indicating LEDs energized thru Capacitive Voltage Dididers Transparent Viewing window for verification of Earthing Right Angle terminal protectors /Boots IDMT relay for Circuit Breakers self powered, Merlin Gerin type VIP35 or equivalent with required protection CTs of suitable ratio Cable box for incoming and outgoing shall be suitable for icrminating, 11KV, XLPE insulated Aluminium conductor armoured cables One set inbuilt DC power packTransformer protection relays as required as per SLD
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
Uttar Pradesh View Result →
32.
Agriculture #10759745 Price Bid
1 Supply, installation, testingand commissioning of 30 KVA, 3 Phase, 415 V AC, 50 Hz, 0.8 PF (lag), Silent DG Set (CPCB IV+) comprising of Engine coupled with alternatormounted on a common base frame. The DG set shall comprising of following; 1) The Engine (confirming to IS 10002) developing minimum 42 BHP at 1500 RPM, liquid cooled with radiator and fan, Turbo charged, powered by minimum four (4) strokes, multi cylinder, shall be automatic electric starting by 12 V DC starter motor system (battery capactity 90 Ah) and fitted with Electronic Governor (confirming to IS 10000) 2) DG set is capable of delivering an output of 10% in excess of rated KVA for a period of 1 hr in any period of 12 hrs continous running.3) The alternator (confirming to IS 4722) shall be brushless type, self-excited and self-regulated. The alternator must be provided with IP 23 protection with class-H insulation.Alternator efficiency at 100% load (0.8 pf) is not less than 88% and maximum voltage dip at full load (0.8 pf lag) is less than 20%.4) Instrument Control Panel shall be furnished for the engine and shall be comprising of Push Button, Water temperature gauge, Hour meter with RPM indicator, Lube oil pressure gauge.5) DG set complete with Acoustic enclosure shall be made of Pre-treated and Powder coated CRCA Sheet with vermin proof. Along with Residential Silencer and noise level less than or equal to 75 db at a distance of 1 m from of Acoustic enclosure (confirming toIS 8528- 10). DG accoustic enclosure shall have inbuilt fuel tank of minimum 70 litres capacity and fuel piping (between fuel tank and diesel engine), valves, level indications, oil filter and allstandard accessories. MS pipes, heavy class of suitable dia shall be used for fuel piping . Glass window on acoustic enclosure in front of the control panel and emergency stop switch outside the acoustic enclosure.6) DG set should be provided with remote monitoring system to share real time genset information and can be acceseed via mobile device or desktop.7) AVM Pads as per engine manufacturer standard shall be provided for DG set.8) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided.9) Type Approval Certicate (as per CPCB IV norms) for the specified rating of the Power Generator from any of the designated agency authorized by CPCB,Type test report for Alternator latest to conform the specications. Company warranty certificate for 2 years on complete DG set shall be provided. 2 Fabrication, Supplying, Installation, Testing & Commissioning of AMF control panel. The Panel shall be free standing, floor mounted, metal clad cubicle type in construction, to form a compact assembly in dust / damp and vermin proof type, equivalent to IP-53. The thickness of sheet steel members shall not be less than 1.6 mm for cold rolled steel. AMF panel shall be complete with all accessories such as changeover Contactors/MCCBs having sufficient rating, AMF relays etc. for auto changeover of supply from Grid to DG set and vice-versa. Electrical Protections shall be provided through Numerical relays. Required CTs & PTs for metering and protection shall be included. All necessary control and supervisory equipment for the automatic operation of the set shall be included in the panel. Suitable rating of MCCB with over-load and short-circuit protection shall be mounted in the Control Panel for the isolation of loads. MCBs shall be provided for the isolation / protection of control circuit. AMF panel shall be equipped with meters displaying the parameters like Voltage,current , frequency, speed, KVA, KW, Power Factor, fuel Level, Engine running hour counter,Lube Oil Pressure and Engine temperature, etc. 3 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 4 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 5 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 6 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 7 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. 8 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 9 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 10 All kinds of soil 11 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 13 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 14 Centering and shuttering including strutting, propping etc. and removal of form for 15 Foundations, footings, bases of columns, etc. for mass concrete. 16 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. 17 Thermo-Mechanically Treated bars of grade Fe-500D or more. 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 19 Cement mortar 1:4 (1 cement : 4 coarse sand) 20 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 21 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 22 6 mm cement plaster of mix : 23 1:3 (1 cement : 3 fine sand) 24 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 25 Hot finished welded type tubes. 26 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of total thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 27 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. 28 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 29 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 30 Supplying ofXLPE Armoured cable with aluminium conductor of 1.1 KV grade confirming to IS:7098 (Part- I) 1988 with up to date ammendments of the following sizeas required. 31 3.5 x 50 sq. mm 32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 33 3½ X 50 sq. mm (35mm) 34 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 35 Above 35 sq. mm and upto 95 sq. mm 36 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 37 Above 35 sq. mm and upto 95 sq. mm 38 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 39 Above 35 sq. mm and upto 95 sq. mm 40 Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
33.
Rural Development #10733231 Price Bid
Conservation And Beautification Of Waghapur Lake Tal. Bhudargad Dist. Kolhapur- 1 Sub-work No. 1 -Desilting, Deweeding and Dewatering Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material up to a distance of 50 metres beyond the building area and stacking as directed ,including dewatering, preparing the bed for the foundation and necessary back filling with a vailable earth / murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means 2 Excavation for foundation in Hard-rock by controlled blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres. from the building area including dewatering and backfilling with available earth soil / murum watering, ramming etc. complete. (Lift upto 1.5m) By Mechanical Means 3 Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary forfoundation and other parts of the the works and pumping out water during and after excavation as may be required by using 10.0 to 19.0 BHP pump etc. complete. ( prior approval of Super intending Engineer will be necessary) 4 Desilting the Lake in wet or dry condition excluding Conveying materials obtained from Lake beyond the work site, stacking, spreading,etc. complete 5 Conveying materials obtained from Lake including all lifts, laying in layers of 20 cm. to 30 cm. breaking clods, dressing to the required lines, curves,grade sand section, watering and compacting to not less than 97% of standard proctor density for a lead of 300m. to 500 m. inclusive, from the site of excavation to the site of deposition as directed.20 % to Farm 6 80 % to Dump Yard 7 Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and a like grass along roadside making the ground clean by showel and phavaras etc. complete. 8 Sub Work No. 2 - Gabion Wall Providing and Constructing gabion structure 1Meter high or required section madeup of soft mechanically woven hexagonal shaped G.I. wire confirming to IS 16014:2012 having zinc plus PVC coating of overall diameter of 3.7 mm and tying lacing wire of 3.2 mm with edge wire confirming to overall diameter 4.4 mm edges being mechanically selvedged including placing inposition, fitting neatly with trap stone rubble (15 to 23 cm ) all loose ends to be securely tied (Excluding transportation) etc. complete. (In Dry condition and for under water installation extra cost to be considered) 9 Filling in plinth and floors with approved excavated material in 15 cm. to 20 cm. Layers including watering and compacting etc. complete. 10 Sub Work No. 3 - Earthen Bank Protection WorkExcavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 11 Excavation for foundation in hard murum and Boulders including removing the excavated material up to distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc.complete. (Lift upto 1.50 m) By Mechanical Means 12 Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap / ganite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying / pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 13 Providing andl aying Cast in situ / Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork, cover blocks, laying / pumping, compaction and curing roughening the surface if special finish is tobe provided ( Excluding reinforcement and structural steel ) etc. complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 14 Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, coverblocks, laying / pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer /concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 15 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pilecaps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars,bindingwith wires or tack welding and supporting as required complete. 16 Filling in plinth and floors with approved excavated material in 15 cm. to 20cm. Layers including watering and compacting etc. complete. 17 Providing expansion joints with 25 mm thick bituminous pad as per detailed drawings etc. complete. 18 Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete. 19 Sub Work No. 4 - Ghat Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 20 Excavation for foundation in hard murum including removing the excavated material up to distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc.complete. (Lift upto 1.50 m) By Mechanical Means 21 Providing soling using 80 mm size trap metal in 15cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 22 Providing and laying in situ / ready mix cement concrete of M-10 proportion with trap / granite / quartzite / gneiss metal in foundation including necessary formwork, compacting and curing etc. complete. (with reversible drum type mixer with SCADA with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ) 23 Providing and laying insitu / ready mix M-20 cement concrete of trap / granite / quartzite / gneiss metal for approach slab / Rigid pavement including compacting ,finishing, curingetc. complete. (excluding reinforcement ) (with reversible drum type mixer /concrete batch mix plant (pan mixer) with SCADA with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ), cement 6.40 bags/cumt) 24 Providing selected hard murum filling including laying in layers of 15 to 20 cm with watering and compacting etc. complete. 25 Providing andl aying Cast in situ / Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork, cover blocks, laying / pumping, compaction and curing roughening the surface if special finish is tobe provided ( Excluding reinforcement and structural steel ) etc. complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 26 Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, coverblocks, laying / pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer /concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 27 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pilecaps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars,bindingwith wires or tack welding and supporting as required complete. 28 Sub Work No. 5 - Stone Pitching Excavation for foundation in hard murum and Boulders including removing the excavated material up to distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc.complete. (Lift upto 1.50 m) By Mechanical Means 29 Providing selected hard murum filling including laying in layers of 15 to 20 cm with watering and compacting etc. complete. 30 Providing dry rubble stone pitching 23 cm (about 9 inch) thick including all material, quarry spalls, labour etc. complete. 31 Sub Work No. 6 - PathwayExcavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means 32 Providing dry / trap / granite / quart zite / gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. 33 Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying / pumping, compacting, roughening the mif special finishis to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 34 Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram / Sq. cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete 35 Providing and laying Cast in situ / Ready Mix cement concrete in M15 of trap /granite / quartzite / gneiss metal for bed blocks, foundation blocks and such other items in cluding bailing out water, Steel centering, formwork, laying / pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honey combed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honey combed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed. ), with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 36 Providing and fixing Guard Railing of 1000 mm height as per Type D Drg. No. 15 dt . 20 - 4 -79 , and fixed in 40 x 40 x 6 mm iron, angle embedded in 1:2:4 cement concrete bedding patti as per detailed drawing, with 3 coats of approved of yellow and black paint. 37 Sub Work No. 7 - Public Toilet BlockExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) 38 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd�A-3/259) 39 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 40 Providing and laying in situ Cement Concrete M-10 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) PCC M - 10 41 Providing uncoursed rubble stone masonry of trap/ granite/ quartzite/ gneiss metal in CM 1:5 for foundation of piers, abutments, wings etc. including bailing out of water, striking joints, scaffolding and watering etc. complete. 42 Filling in plinth & floors with approved excavated materials in 15 cm layers including watering &compacting complete 43 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) R.C.C. LINTEL-150 44 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. 45 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slab M200 46 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete(including cost of binding wire). (Bd-F- 17/306)TOR Steel 47 Providing and fixing M40 grade tick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S.65241983 having 6mm dia.bars3 Nos. And stirrups @ 250 mmc/cand fixing in wall with 6 Nos of hold fast of 12mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . 48 Providing and fixing solid core flush door shutter commercial in single leaf 32 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron holdfast, stainless steel fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. 49 Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 50mm thick with 3mm diameter mild steel bar reinforcement,of approved design on both side, fixing in cement mortar 1:3 and curing etc. complet 50 Providing internal cement plaster 12 mm thick in a single coat in C.M.1:3 without neru finish to masonry , concrete surface in all positions including scaffolding and curing complete. 51 Providing and laying matt finish ceramic tiles of having size 30 cmx 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. 52 Providing and laying cement concrete flooring 40mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30cmx30cm or other size laid diagonally/square etc finishing smooth (with extra cement )in any colour as directed and curing etc.complete.with Crushed sand VSI Grade 53 Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to correspondng I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. 54 Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black back lite seat with all necessary pipe connection etc. complete. 55 Providing and fixing white glazed earthenware Wash Hand Basin of 45cm. x 30cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 56 Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. 57 Providing and fixing on walls/ceiling/ floor 15mm dia. CPVC pipe with necessary fittings, remaking good the demolished portionetc.complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 58 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and withnecessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc.complete. 59 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/ waste pipe and with necessary fxtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. As directed by Engineer 60 Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters 61 Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. 62 Providing and fixing Bib cock stop tap of brass heavy of 15 mm dia. At site of work 63 Providing and fixing partition with kadappa stone of all size sand 25 mm thick polished on both side and edge stoorig in a lncluding fixing in position in cement mortor 1:4 curing polish-ing, cleaning etc complete. 64 Name plate with wording as directed on plastered srface in oil painting 65 Providing and fixing orissa type colour glazed earthen ware 625x450 mm. w.c. pan including trap, C.I. soil and vent pipe upto the outside face of wall including 100mm. dia. C.I. plug, bend, 15mm. thick 10 litre PVC flushing cistern with all necessary pipe connection etc. complete. 66 Sub Work No. 8 - Compound Chainlink FencingProviding and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle ( 50 x 50 x 6mm ) postat 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in (1:4:8) cement concrete block of 45x45x45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete 67 Sub Work No. 9 - Beautification Work(Environmental Awareness, Benches, Solar Street Light, Dustbin, Sign Board, Open gym, Children Play Equipment) Providing and fixing VIP Bench CI Frame height 5.48 mêter and weight 30 kilogram Decorative Leg, Seat plates FRi Patrujan hot press size metre x 1.20 metre long, wood finish, both side PP Cap for fixing 12.5 milimeter Stainless steel Nut bolt toatal 9 seat plates etc complete. 68 Providing and Fixing Solar Street light. Power Output > 75 Wp at 16.4 +- 0.2 Volts at STC,Battery Capacit > 12.8V (nominal), 30 Ah at STC (1 Day Autonomy), Type of LED 20 Watt white LED Type,Ingress Protection IP 65 or Better,Indicator on The system - 2 LED Indicators Red and Green. 69 Providing and Fixing Pegwin Shape dustbin FRP 3 feet height, baok side door size 1 feet x 1 feet for removing garbage in fixing concrete etc. complete. 70 Providing and fixing road junction/ information sign boards of size 1.80 x 1.20 Meter Prepared 16 guage M.S.sheet on frame of size 40x40x5 mm with cross bracing of size 35x35 x 5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral /arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection includingtwo angle iron post of size 65 x 65 x 6 mm of 3.65 m. long inflated at bottom drilled on top and painted in whiteand black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size as directed by Engineer-in- charge etc. complete.Mild Steel Board with Engineering Grade. 71 Providing and fixing informatory sign boards of size 0.90 x 0.60 m made out of 14 guage Aluminum sheet bonded with IRC Specified colour of retro reflective sheeting of Type IV High Intensity Micro-Prismatic Grade Sheeting (HIP) having pressure sensitive / heat activated adhesive, IRC Specified colour retro reflective cutout border & messages having pressure sensitive adhesive having border & messages in IRC Specified colour background including on frame of with angle iron frame of size 35 x 35 x 5 mm and two M.S. angle iron post of size 65 mm X 65 mm X 6 mm, 3.65 m long, duly painted with flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in 1:4:8 concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Alluminium sheet Type IV High Intensity Micro Prismatic Grade Sheeting 72 Providing and Fixing Open Gym Equipment.Providing and fixing Sit Up Board made from B class Galvanized Iron. pipe. The main frame is of 25 millimeter Nota bene made from C Class Galvanized Iron. Pipe, Perforated sheet of 2 millimeter thickness is welded on main frame. The remaining frame of the sit up board is of 40 millimeter and 50 millimeter Nota bene made from C class Galvanized Iron. pipe. The foundation pipes are embedded in C.C. stock and painting is done by attractive color spraying after proper surface treatment, shot blasting and initial coat of yellow primer surface is applied before top coat. The top coat. The top coat is done using the best quality brand paint or duly powder coated. 73 Providing and fixing Sky Walker made from B Class Galvanized Iron.Pipe. The main frame is Diameter 80 millimeter made from C class pipe. The outer ring of sky walker is Diameter 32 millimeter made from C Class Galvanized Iron Pipe. For connecting the handle frame to main pipe Diameter 60 millimeter C Class Galvanized Iron Pipe is used. The bottom support of Mild Steel, round plate of Diameter 250 millimeter X 10 millimeter thickness is welded at bottom. The leg movement frame is of 50 X 50 millimeter X 2 millimeter thick cyclic redundancy check square pipe. The handle frame is of Diameter 40 millimeter made from C* Class Galvanized. Iron Pipe. The foundation used for fixing is 80 X 40 millimeter X3 millimeter thickness C-Channel. The footrests is made from Aluminum casting material, its sizes are 130 X 310 X 5 millimeter Closing caps made from top quality Fibre-reinforced plastic material with 2 millimeter thickness and Plastic cap are used. The pins used bearing of reputed make (SKF/FAG). High tensile steel with galvanized nut bolts are used for assembly. The serclips used for assembly are of 25 millimeter The powder coat is done by Poly urethane and epoxy powder with 60 to 70 micron thickness. 74 Providing and fixing cross trainer made from B class Galyanized Iron.pipe. The center pipe is of 80 millimeter Nola bene made Tram C Class Galvanised Iron. pipe, and the bottom support of Mild Steel Round plate of 250 millimeter dare an a rat ho tomieter thickness is welded at bottom. The handle frame is made up 25 millimeter Nota bene C Class Galvanized Iron. Round Pipe. The foundation used for fixing is consists of three equal items that is. 100 millimeler Nota bene made from C Class Galvanised Iron. Round Pipo, Mild Steel Round Plate of 250 millimeter diameter and 10 millimeter thickness, 25 millimeter X 25 millimeter Mild Steel Angle of 3 millimeter Thickness. To join the Centre pipe and handle Frame Seamless Pipe of 50 millimeter origin destination and 3 millimeter Mild Steel Angle of 3 millimeter Thickness is used. For the movement, Bushes are used and for it 60 millimeter origin - destinatior and 3 millimeter thickness. The footrests is made from Fibre-reinforced plastic/C.1/Aluminum casting material, its size are 130 millimeter X 300 millimeter and 300 millimeter and 5 millimeter thickness. For support of Footrest of Cross trainer 130 millimeter X 300 millimeter with § millimeter thickness Mild Steel Plate and 50 millimeter X 50 millimeter cyclic redundancy check Square pipe with 3 millimeter thickness is used.Closing caps made from top quality Fibre-reinforced plastic material which is of 2 millimeter thickness. The pins used is made up of 25 millimeter diameter Harden bright bar. The bearings used are of 6205 permanent lubricated sealed bearing of reputed make. The handles used for cross trainer are of Rubber grip. The nut bolts used for assembly are made from S.S. material. The foundation pipes are embedded in C.C. stock and painting is done by attractive color spraying after proper surface treatment, Shot blasting and initial coat of yellow primer surface is applied before top coat. The top coat is done using the best quality brand paint or duly powder coated 75 Providing and fixing chest press made from B Class Galvanized Iron. Pipe. The Center Pipe is of 100 millimeter MB made from C Class Number Galvanised Iron. Round Pipe, and the bottom support of Mild Steel Round plate of 250 millimeter and 10 millimeter thickness is welded at bottom. The remaining frame is made up of 40 millimeter Not bene C class Galvanized Iron. Pipe. The handle frame is made up of 25 millimeter Nota bene C* Class Galvanised Iron. Pipe, The seat frame is made up of 40 millimeter Nota bene and 50 millimeter Nota bene C class Galvanized Iron. Pipe. For the assembly different bushes are used for fixing is consists of three equal items that is. 100 millimeter Nota bene made from C Class Galvanized Iron. Pipe, Mild Steel Round plate of 250 millimeter dia and 10 millimeter thickness and 25 millimeter X 25 millimeter X3 millimeter Mild Steel angle. The seats is fitted on the outer frame is made up of high quality Fibre-reinforced plastic material of size 330 millimeter X 330 millimeter of thickness 3 millimeter and Mild Steel Plate of thickness 5 millimeter and size 250 millimeter X 200 millimeter is used to support it. Closing caps are made from top quality Fibre-reinforced plastic material which is of 2 millimeter thickness. The pins used are made up of 25 millimeter and 17 millimeter dia solid bar. The bearing used are 6205 and 6203 permanent lubricated sealed bearing of reputed make. The nut bolt used for assembly are made from stainless steel material. The serclips used for assembly is of 25 millimeter diameter. The Poly Urethin plastic bush is used for handling. The foundation pipes are embedded in C.C. stock and painting is done by attractive color spraying after proper surface treatment, shot blasting and initial coat of yellow primer surface is applied before top coat. The top coat is done using the best quality brand paint or duly powder coated 76 Providing and fixing Back extension made from B Class Galvanized Iron Pipe. The main frame of diametre 90 millimeter made from C Class Galvanized Iron Pipe, and the leg movement frame is of diameter 40 millimeter made from C Class Galvanized pipe. The handle frame is of diametre 32 millimeter made from C class Galvanized Iron Pipe. The seats is fitt a on the frame is made up of high quality FRP material of size 330 millimeter × 300 millimeter of thickness 3 millimeter and Mild Steel Plate of thickness 5 millimeter and size 250 millimeter × 200 millimeter is used to support it. The Foundation used for fixing is consists of 25 millimeter × 25 millimeter Mild Steel angle of 3 millimeter thickness. The footrests. is made from Aluminum casting material, its sizes are 130 millimeter x 310 millimeter x 5 millimeter. For the support diameter 32 millimeter made from C Class Galvanized Iron Pipe. closing caps made from top quality FRP material with 2 millimeter thickness. The powder coat is done by Poly urethane and Epoxy powder with 60 to 70 micron thickness. 77 Providing and fixing Rower made from B Class Galvanized Iron. Pipe, The main frame is 80 millimeter X 40 millimeter and 40 millimeter X 40 millimeter cyolio redundancy check Pipe with 2 millimeter thickness. The handle frame Is of 25 Nota bene made from C class Galvanized Iron. Pipe. The Foundation used for fixing consists of three equal items that is. 40 millimeter Nota benc made from C class Galvanized Iron. Pipe, C channel of 75 millimeter X. 40 millimeter X 5 millimeter and 25 millimeter X 3 millimeter Mild Steel angle. To join the movement frame to main frame seamless pipe of 50 millimeter diametermeter and 3 millimeter thickness is used. The seats which are fitted on the main frame is made up of high quality Fiber-reinforced plastic material of size 330 millimeter X 330 millimeter of thickness 3 millimeter and Mild Steel plate of size 250 millimeter X 200 millimeter X 5 millimeter is used to support it. Closing caps are made from top quality Fiber-reinforced plastic material which is of 2 millimeter thickness. The pins used are made up of 17 millimeter diametermeter hardened bright bar. The bearings used are of 6203 permanent lubricated sealed bearing of reputed male. The handles used are of Rubber grip. The nut bolts. used for assembly are made from Stainless Steel material. The bushes (Stoppet) used to avoid the collusion made from poly urethane plastic material of 50: millimeter diamefermeter The serclips used for assembly is of 17 millimeter diametermeter. The foundation pipes are embedded in Cement Concrete stock and painting is done by attractive color spraying after proper surface treatment, shot blasting and intial coat of yellow primer surface is plied before top coat. ithe top. coat is done using the best quality brand paint or duly powder coated. 78 Providing and fixing uneven bar made, from B class Galvanized Iron Pipe. The main frame is: 115 milliteter-diametermeter made from C class pipe and. the bottom support: of Mild Steei Round Plate of Diametermeter 250 millimeter and 10 millimeter thickness is welded at bottom. The handle frame istof diametermeter 40 millimeter made from C class Galvanized Iron Pipe. The foundation ised for fixing is consists of three equal item that is diametermeter 90 millimeter made from C Class Galvanized Iron, Mild Steel Round Plate of diametermeter 250 millimeter and 10 millimeter thickness and 25 millimeter × 25 millimeter mild steel angle of 3 millimeter thickness. Closing caps are made from top quality Fiber Reinforcement Plastic material which is of 2 millimeter thickness. The Powder coat is done by Poly urethane and epoxy powder coat with 60 to 70 micron thickness. 79 Providing and fixing Weight Lift as directed by engincer-in-charge 80 Providing and fixing combination leg press + standing twister + seating twister as directed by engineer-in-charge 81 Providing and fixing Air walker made from B class Galvanized Iron pipe. The center pipe is of 80 millimeter Notabene made from C Class Galvanized Iron pipe, and the bottom support of Mild Steel round plate of 250 millimeter diameter & 10 millimeter thickness is welded at bottom. The leg movement frame is of 40 millimeter NB made from C Class Galvanized Iron pipe. The handle frame is of 25millimeter Notaben made from C Class Galvanized Iron pipe. The foundation used for fixing is consists of three equal items i.c. 80millimeter Notabene made from C Class Galvanized Iron pipe, Mild Steel Round plate of 250 millimeter diameter & 10millimeter thickness & 25millimeter X 25millimeter Mild Steel angle of 3 millimeter thickness. To join the centre pipe & leg movement frame seamless pipe of 60 millimeter diameter & 3millimeter angle of 3millimeter thickness. To join the centre pipe & leg movement frame seamless plpe of 60mlllimeter diameter & 3millimeter thickness & 60millimeter thickness.. The footrests is made from FRP/Cast Iron /Aluminum casting Hamaterial, its sizes are 130millimeter X 300millimeter X Smillimeter. For the support 50millimeter X 50millimeter X millimeter CRC square pipe is used. Closing caps made from top quality Fiber Reinforced Plastic material with 2 millimeter thickness. The pins used are made up of 25 millimeter diameter bright bar. The bearings used are6205 permanent lubricated sealed bearing of reputed make. The nut bolts used for assembly are made from Stainless Steel material. The serclips used for assembly are made from Stainless Steel material. The serclips used for assembly are of 25millimeter diameter. The foundation pipes are embedded in Cement Concrete, stock and painting is done by attractive color spraying afler proper surface treatment, Shot blasting and initial coat of yellow primer surface is applied before top coat. The top coat is done using the best quality brand paint orduly powder coated 82 Providing and fixing Parallel bar of height 1.3 meter Galvanised Iron Pipes of A Class quality. The frathe of the parallel bar shall be of 40 milimeter Nominal Bore pipe. The vertical support pipe shall be embedded with holdfast in Cement Concrete:block of 0.3.X 0.3 X:0.3 meter below ground level. The total play area for the equipment shall be 0.9 X 0,5 meter painting is done by spraying after proper surface treatment and an initial coat of yellow primer surface is applied before top coat. The top coat is done using the best quality brand paint or duly powder coated. 83 Providing and fixing Super Max Multi Play System made for roto moulded FRP 4 Tanel slide 1.9 feet dia, with FRP panel made for roto moulded FR$ Tanel Spiral Slide 1.50 metre height, 6 feet length tanel bridge, FRP Panel, canopy made for roto moulded FRP size 3 x 3 feet with 7 feet length ladder including railing 25 millimeter NB Pipe, 10 feet height 80 millimeter diameter Tower Pol, 2milimeter thick platform percoated sheet size 3 x 3 feet, High Tension Blackning, Tanel Slide leg 40 millimeter pipe, Spiral slide main support 75 millimeter dia 5 feet length, all mild steel material used in P.P. Grade powder coating with forpeting process excetra complete 84 Providing and fixing Double Swing with 9 feet leg using 38 millimeter NB Pipe, 10 feet: Top Bar lengch 50 milimeter ISI Mark NB Pipe, Rubber Coated Chain with Suspension, attached rubber sheet, including S type Hook, moulded bearing clarap, P.P. grade powder coating with fospeting complete. including welding and handling charges with mild steel pocket excetra complete. 85 Sub Work No. 10 - Afforestrtion / Plantation -Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means 86 Filling fresh garden soil /silt & manure in excavated area including lead upto a distance of 50 mtrs (1/10 of unskilled labour) 87 Preparing Lawn:- Excavating the ground to a required depth of 30cms.removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manure are in 3:1 proportion to a height of 20cms. Mixing garden soil and manure thoroughly, well, levelling, watering on previous night. Planting required variety of lawn grass (Cynadon or paspallum) as directed and maintaining till well established by watering, weeding, clipping, rolling etc.complete 88 Preparing flower bed :- Hibiscus (8 x 10) Excavating the ground to required depth of 30cms removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & Manure in excavated area in 3:1 proportion to a height of 40cms. Mixing garden soil & manure thoroughly well, levelling, watering on previous night. Planting well rooted shrubs 0.5 meters apart as directed and maintaining till well established by watering,weeding, stirring, replacing casualties etc.complete. 89 Preparing Shrubbery :- Plumeria Rubra (21 x 21) Excavating the ground to required depth of 30cms removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & MAnure in excavated area in 3:1 proportion to a height of 30cms.Mixing O garden soil & manure thoroughly well, levelling watering on previous night. Planting well rooted shrubs 0.5 meters apart as directed and maintaining till well established by atering,weeding, stirring, replacing casualties etc.complete 90 Mogra Plant/Creepers /Climbers -Excavation pit with size 0.30x 0.30x 0.30 removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.15 mt with fresh garden soil and manure in 3:1 propration.Mixing soil and manure thoroughly well levelling,watering on previous night .planting one or two year old healty plant as per specification Maintaning till well established by watering etc,complet , weeding pruning, sirring replacing casualties. Gardenia Lasmirals (Motha Mogara) 8 x 10 91 Jasmin (Mogara) 8 x 10 92 Planting large flowering /shady trees (ht.1.00 mt): Digging pit with size 0.9 m x 0.9 m x 0.9 m, removing and conveying unwanted stuff to a required distance as directed Filling the pit with approved excavated material upto to a height of 0.30 m and reamaining height of 0.60 m. with fresh garden soil and manure in 3:1 proporation mixing soil and manure throughly well leveling, as directed watering, previous night, planting two to three year old minimum 1.00 mtr height, helthy trees spaling as per specefications, Maintaing till well established by watering weeding,sirring of soil replacing of casualties etc complete, Delenia indica (Green Chafa) 21 x 21 93 Planting large flowering /shady trees (ht.2.00 mt): Digging pit with size 0.9 m x 0.9 m x 0.9 m, removing and conveying unwanted stuff to a required distance as directed Filling the pit with approved excavated material upto to a height of 0.30 m and reamaining height of 0.60 m. with fresh garden soil and manure in 3:1 proporation mixing soil and manure throughly well leveling, as directed watering, previous night, planting two to three year old minimum 2.00 mtr height, helthy trees spaling as per specefications, Maintaing till well established by watering ,weeding,sirring of soil replacing of casualties etc complete. Delonix Regia (Gulmohar) 14 x 16 94 Planting small and medium size ornamental /flowering plant Planting small and mediumsize ornamental or flowering plant. Digging pit with size 0.6 m x 0.6 m x 0.6 m, removing and conveying unwanted stuff soil and Farm Yard Manure up to a height of 0.60 m in 3:1 proportion, mixing soil and manure thoroughly well, leveling and watering previous night. Planting one or two year old healthy plant saplings as per specifications. Maintaining till well established by watering. Stirring of soil and manure, replacing of casualties etc. completePeepal 8 x 10 95 Rubber Plant 10 pot 96 Moringa (Shevga) 5 x 6 97 Sonchafa 8 x 10 98 Supply and installation of drip irrigation system all along the plantation /lawn area including all components and accessories etc complete 99 Bamboo Golden 13 x 13 - Excavation pit with size 0.30x 0.30x 0.30 removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 40 cm with fresh garden soil and manure in 3:1 propration.Mixing soil and manure thoroughly well levelling,watering on previous night .planting one or two year old healty plant as per specification Maintaning till well established by watering etc,complet , weeding pruning, sirring replacing casualties 100 Evergreen perennial typically grown- Excavation pit with size 0.25 x 0.25 x 0.25 removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 80 cm with fresh garden soil and manure in 3:1 propration.Mixing soil and manure thoroughly well levelling,watering on previous night .planting one or two year old healty plant as per specification Maintaning till well established by watering etc,complet , weeding pruning, sirring replacing casualtiesCanna (Kardal) 5 x 6 101 Snake Plant 10 pot 102 Arecaplam 13 x 13 103 Spider lilly 5 x 6 104 Weeping Fig 6 pot 105 Tulsi 5 x 6 106 Providing labour for plantation of different types of plants and trees, include excavating pit, watering the plant etc. Complete Mali 107 Mazdoor - Unskilled Heavy Male 108 Tree Cutter - Semi Skilled
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
34.
Textiles #10732252 AOC
Supply, Installation, Testing And Commissioning Of Cctv Surveillance System At 140 Warehouse Locations-2 Supply & erecting of high defination 5 MP IP IR Bullet camera with Sensor : 1/3, progressive scan, 5.0 megapixel, CMOS, Lens : [email protected]/ [email protected], Shutter Speed : Auto/Manual, 1 ~ 1/100000s, Digital noise reduction : 2D/3D DN, Day/Night : IR-cut filter with auto switch (ICR), Minimum Illumination: Colour: 0.03Lux (F2.0, AGC ON) 0Lux with IR, IR Range : Up to 30m (98ft) IR range, S/N : >56dB, Defog:Digital Defog , WDR: DWDR/ True WDR, Resolution : 5 MP or better ( 2592x1944), Video Compression : H.265 / H.265+, High Light Compensations : TRUE, Back Light Compensations :TRUE,Network : 1 RJ45 100M Base-TX Ethernet, Audio : Audio In / Out Support,Power : 12V DC / PoE, Housing : IP67 , CERTIFICATION : Vendor should submit Mfr. Test Certificate,Cyber Security : AES 256-bit Encryption, Configuration encryption, trusted execution, digest, security logs,WSSE ,account lockout,syslog, video encryption, IP/MAC filtering ,HTTPS,Trusted upgrade,trusted boot., ANR Support : Yes with 512 GB For details technical specification no 13. 3 Supply, installation, testing and commissioning of 8 channel network video recorder with Processor : Quad-core embedded processor, IP Camera Input : 8 channels, Operating System : Embedded LINUX, Two-way Talk : 1 Channel Input, 1 Channel Output, RCA, User Interface : GUI, Video Output : 2 HDMI, 2 VGA, Compression : Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Decoding Capability : 8-ch@1080P(30fps), 16-ch@1080P(30fps), OSD : Camera title, Time, Camera lock, Motion detection, Recording, Video Resolution : HDMI: 3840 × 2160 , 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768 and VGA: 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768, Video Recording : Max 160 Mbps, Video Display Split : 1st Screen: 1/4/8/9/16, 2nd Screen: 1/4/8/9, Motion Detection : MD Zones: 396(22×18). Video Loss: supports, Camera Blank : Supports,Hard Disk : 2 SATA ports, up to 10TB Each, 1 eSATA port, Smart Phone : iPhone, iPad, Android Phone, Trigger Events : Recording, PTZ, Tour, Alarm, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips, Recording Mode : Manual; schedule (general; MD; alarm; MD & alarm; intelligent; POS), Search Mode : Time /Date, Alarm, MD and Exact Search (accurate to second) , Bit Rate : 16Kbps ~ 20Mbps Per Channel , Sync Playback : 1/4/9/16 , Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoom , Backup Mode : USB Device/Network, Interface Ports : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 ), 1 RS232, 1 RS485 , Max User Account : 128 users , Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec , Ethernet : 1 RJ-45 Port (10/100/1000Mbps) , Protocols : HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search , ONVIF 2.4, SDK, CGI , Power Supply : Single, AC 100~240V, 50/60 Hz/Single, DC12V/4A , Power Consumption : <9.5W (Without HDD) , Certification : UL,CE,FCC,BIS For details technical specification no 16. 4 Supply, installation, testing and commissioning of 16 channel network video recorder with Processor : Quad-core embedded processor, IP Camera Input : 16 channels, Operating System : Embedded LINUX, Two-way Talk : 1 Channel Input, 1 Channel Output, RCA, User Interface : GUI, Video Output : 2 HDMI, 2 VGA, Compression : Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Decoding Capability : 16-ch@1080P(30fps), OSD : Camera title, Time, Camera lock, Motion detection, Recording, Video Resolution : HDMI: 3840 × 2160 , 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768 and VGA: 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768, Video Recording : Max 300 Mbps or better, Video Display Split : 1st Screen: 1/4/8/9/16, 2nd Screen: 1/4/8/9, Motion Detection : MD Zones: 396(22×18). Video Loss: supports, Camera Blank : Supports,Hard Disk : 4 SATA ports, up to 16TB Each, 1 eSATA port, Smart Phone : iPhone, iPad, Android Phone, Trigger Events : Recording, PTZ, Tour, Alarm, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips, Recording Mode : Manual; schedule (general; MD; alarm; MD & alarm; intelligent; POS), Search Mode : Time /Date, Alarm, MD and Exact Search (accurate to second) , Bit Rate : 16Kbps ~ 20Mbps Per Channel , Sync Playback : 1/4/9/16 , Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoom , Backup Mode : USB Device/Network, Interface Ports : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 ), 1 RS232, 1 RS485 , Max User Account : 128 users , Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec , Ethernet : 1 RJ-45 Port (10/100/1000Mbps) , Protocols : HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search , ONVIF 2.4, SDK, CGI , Power Supply : Single, AC 100~240V/Single, DC12V/4A , 50/60 Hz , Power Consumption : <16.7W (Without HDD) , Certification : UL,CE,FCC,BISFor details technical specification no 15. 5 Supply, installation, testing and commissioning of 32 channel network video recorder with Processor : Quad-core embedded processor, IP Camera Input : 32 channels, Operating System : Embedded LINUX, Two-way Talk : 1 Channel Input, 1 Channel Output, RCA, User Interface : GUI, Video Output : 2 HDMI, 2 VGA, Compression : Smart H.265+/H.265/Smart H.264+/H.264/MJPEG, Decoding Capability : 32-ch@1080P(30fps), OSD : Camera title, Time, Camera lock, Motion detection, Recording, Video Resolution : HDMI: 3840 × 2160 , 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768 and VGA: 1920 × 1080 , 1280 × 1024, 1280 × 720 , 1024 × 768, Video Recording : Max 320Mbps, Video Display Split : 1st Screen: 1/4/8/9/16/25/36, 2nd Screen: 1/4/8/9/16, Motion Detection : MD Zones: 396(22×18). Video Loss: supports, Camera Blank : Supports, Hard Disk : 4 SATA ports, up to 20TB Each, 1 eSATA port, Smart Phone : iPhone, iPad, Android Phone, Trigger Events : Recording, PTZ, Tour, Alarm, Video Push, Email, FTP, Snapshot, Buzzer & Screen tips, Recording Mode : Manual; schedule (general; MD; alarm; MD & alarm; intelligent; POS), Search Mode : Time /Date, Alarm, MD and Exact Search (accurate to second) , Bit Rate : 16Kbps ~ 20Mbps Per Channel , Sync Playback : 1/4/9/16 , Playback : Play, Pause, Stop, Rewind, Fast play, Slow play, Next file, Previous file, Next camera, Previous camera, Full screen, Repeat, Shuffle, Backup selection, Digital zoom , Backup Mode : USB Device/Network, Interface Ports : 2 USB Ports (1 Rear USB 3.0 , 1 Front USB 2.0 ), 1 RS232, 1 RS485 , Max User Account : 128 users , Record Interval : 1~120 min (default: 60 min), Pre-record: 1~30 sec, Post-record: 10~300 sec , Ethernet : 1 RJ-45 Port (10/100/1000Mbps) , Protocols : HTTP, HTTPS, TCP/IP, IPv4/IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search , ONVIF 2.4, SDK, CGI , Power Supply : Single, AC 100~240V, 50/60 Hz , Power Consumption : <16.7W (Without HDD) , Certification : UL,CE,FCC,BISFor details technical specification no 14. 6 Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD 7 Supplying & erecting( 32 Monitor ) 32 professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 250 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 2 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc.complete. 8 Supplying & erecting (43 Monitor ) 43 professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete. 9 Supplying & erecting (49 Monitor ) 49professional LED display with 1920*1080 (Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete. 10 Supplying, erecting & terminating 5 m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19pin HDMI connectors complete. 11 Providing & erecting 7 m high (clear height) galvanised Each octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no.OH-PL/OPL. 12 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mmstonemetal,(45 x45 x45)cm/45cmdia.x45cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) 13 Supplying and erecting Lshape mounting for camera (Extender) etc complete as directed by engineer in charge. 14 Supplying , fixing and configuring ethernet managed ethernet each switch of minimum of 24 ports 10/100/1000 Base-T PoE+ ports with min 180W power and 2x 1G SFP portsand 1 x Out of Band IP based management Port with CL1 provided, switch of min. 36 Gbps or morewith non-blocking architecture forwarding rate of 26.8 Mpps rack, equipped with minimum 512MB RAM and 128MB flash, should have LED indicator for per port status, FAN, PSU and Management status and sustain 0°C to 50°C OT and 10% to 95% RH as directed. It should support for IPv6 , cover transmission distance of 250 meter. The swithching and routing should have 16 K MAC Address, 255 active Vlans, 802.1D spanning Tree, 802.1w, 802.1s, should have BPDU Guard, support aggregating and load balancing, 802.1 AK for dynamic VLAN propagation, Local and Remote port mirroring, Link Layer Discovery Protocol (802.1ab), MAC address tracking and address addition, delete or movement. The secutrity LA database for RADIUS Authentication for 802.1x login, SSH-2, SCP for secure management, dynamic arp inspection, DHCP snooping with min50 ACL entry support. Management should consist scheduled archiving / uploading of configuration and system log to a central server, Auto-install support for firmware images and configuration files and vendor shouldsubmit Mfr Test Certificate along with supply as directed by Engineer in chargeas per technical specification no. 1 complete. 15 Supplying , fixing and configuring ethernet managed ethernet each switch of minimum of8 Ports 10/100/1000 Mbps PoE+ 2 nos of1G SFP Ports, 2 Uplink ports, Protocol: IEEE802.3af, IEEE802.3at, Hi-PoE, consumption of PoE Budget: 120 W, with switching capacity 20 Gbp, FR rate 11.90 Mbps, buffer memory 1.5MB, should covertransmission distance 250 meter, MAC Address List- 8k. The lighting protection 6KV, working temperature –10° C to 55° C (14° F to 131° F), Electromagnetic- FCC CFR 47 FCC Part 15 Subpart B, Conforms to CE Standards. Vendor should submit Mfr Test Certificate along with supply as directed by engineer in chargeas per technical specification no. 2 complete. 16 Supplying & erecting Mode SFP transceiver of Single LC receptacle optical interface compliant with 7dB gainetc model, Hot-pluggable SFP footprint type, OW of 1310nm FP laser transmitter, standard RoHS compliant and Lead Free, should reach Up to 10 km on 9/125um SMF, with Metal enclosure for lower EMI, Low power dissipation <600mW, should sustain 0~50°C, Same as Switch make, Vendor should submit Mfr Test Certificate along with supply and complete as directed by engineer in chargeas per technical specification no. 3 complete. 17 Supplying and installing UTP CAT6 copper cablesuitable for networking of type 23 AWG Solid Bare Copper, Unshielded Twisted 4 Pair, Category 6, LSZH jacket complying to testing, cable outer diameter of 5.8mm, frequency 600 MHz; ETL Test Reports of ANSI/TIA-568-C.2 & ISO/IEC 11801 of cable performance upto 600 MHz provided conduit/casing-n-cappingas directed by engineer in charge and per technical specification no. 11. 18 Supplying, installing and testing UTP connector (RJ-45) as per specification no. WG-NAS/UTPC 19 Supplying and fixing 1 m UTP patch cordof Cat 6 type Electrical performance guaranteed to meet or exceed TIA/EIA 568-B 2-1 category 6 and ISO /IEC Category 6/class,certification UL listed, UL-C certified, different color (Green, orange and red with connector complete as directed by engineer in charge and submit mfr test reportas per technical specification no. 12 complete 20 Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. 21 Supplying and installing 6 core Optical Fiber unarmored cable unitube gel filled for access outside building Single Mode, 9/125 microns, bending radious of not more than 20X , 10 GBPS speed compliant to IEC 60793/IEC 60794 standards, change in Attenuation < = 0.05 db/km, Tensile strength >=300 N, Maximum Crush Resistance 1000 N/100mm,OT of -300 C to 500 C, storage temperature of -400 C to 550 C, of standards ISO/IEC11801 TIA/EIA-568-B, Vendor should submit Mfr Test Certificate along with supply complete as directed by engineer in chargeas per technical specification no. 6 complete. 22 Power Cable (MCB with closed box, single phase) -Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper m PVC unarmoured cable provided conduit/trunking/inside pole/Bus bars or any other places. as per technical specification No: 17 23 PVC Conduit with Hanging wire -Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. (1-1-12) 24 Supplying and fixing 6 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fiber cables in provided U rack complete as per specification no. WG-NAS/ LIU 25 Supplying and fixing LIU 12 Port loaded SM with SC connectors ports provision for 12 Nos. of SC Termination. light guide unloaded interconnect unit, rack mounted type, with adapter panel Fully loaded with SCtype duplexfor termination of optical fiber cables, 19 Rack mountingin provided U rack complete as per technical specification no. 7. 26 Supplying and erecting 12 core Fibre termination box (External rack) suitable for FTTx application,IP67 grade, accepts up to 12 fusion splice, splice tray should be with adaptors and couplers as per requirement, PVC, material of Solid and fully-closed structure of dust-proof, pleasing and neat appearance, ferruling of each core as per standards provided at the time of installation etc complete as directed by engineer in charge.Vendor should submit Mfr Test Certificate along with supplyas per technical specification no. 8 complete. 27 Supplying and erecting 6 core Fibre termination box (External rack) suitable for FTTx application,IP67 grade, accepts up to 6 fusion splice, splice tray should be with adaptors and couplers as per requirement, PVC, material of Solid and fully-closed structure of dust-proof, pleasing and neat appearance, ferruling of each core as per standards provided at the time of installation etc complete as directed by engineer in charge. Vendor should submit Mfr Test Certificate along with supplyas per technical specification no. 8 complete. 28 Supplying and installing single mode simplex pigtail with SC/LC splicing, SC Connector with single mode fiber pigtail (To be used for arc fusion splicing with Fiber cores termination inside LIU/fiber interconnecting panel.) Pigtail consists of pre-moulded/prefabricated SC type fiber connector at one end & another end fiber core with approx. 1 meter length as directed and Vendor should submit Mfr. Test Certificate along with supplyas per technical specification no. 10 complete 29 Supplying and erecting duplexOFC patch cord SC-LC typefibre patch cord, SC-SC /SC-LC duplex, of 1 meter lengthetc complete as directed by engineer in charge. Vendor should submit Mfr. Test Certificate along with supply.as per technical specification no. 9 complete 30 Supplying and fixing 6Uwall mount rack or better, Two Vertical and 2 horizontal cable managers, PD of 5 points- 5 AMP socket, depth of 550 mm or as per NVR sizing, Aluminum extruded profile,compliance CE & RoHS , Glass door in front with lock, With min 2 fans for outdoor,19” equipment mounting or extra width, with 1 tray, should confirm standard of DIN41494 or equivalent ISO9001:2015 and 14001:2015. Vendor should submit Mfr Test Certificate along with supply as directed by engineer in charge as per technical specification no. 5 complete. 31 Supplying and fixingOutdoor 4Uwall mount rack or size as per requirement; bidder to study each PoP location and confirm size in technical and commercial offer, one Vertical and one horizontal cable manager if required, power distrubution with min 3 points- 5 AMP socket or as per site requirement, depth of 400 mm, Aluminum extruded profile , IP rating of 67 if outdoor use,Glass door in front with lock or metal door with perforations, fan type ventilation to be provided for outdoor unit as per requirement at site. Vendor should submit Mfr Test Certificate along with supply as directed by engineer in charge as per technical specification no. 4 complete. 32 Supplying, erecting, testing and commissioning of 2KVA online UPS with Isolation Transformer& 2 KVA = 2 KW capacity online pure sine wave UPS, with batteries PWM & IGBT based, with 0.9 to unity output pf complete with all protections as per technical specification no. 18 complete.
Contract Date: May 15, 2026 Contract Value : 7.88 Crore
Government Departments No of Bidders 8
Maharashtra View Result →
35.
Rural Development #10721339 Price Bid
Tender For Annual Plan-Chungathara Grama Panchayath Electrification Of Mcf-S0149/25-General Electrical Work - ELECTRIFICATION 2 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 3 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 4 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture 5 OD26363/2025-2026:Supply Conveyance, installation, testing and commissioning of 50 LED Flood light with IP 65 protection LED Chip make acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance,including giving connections with required length ofPVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS etc as required. 6 OD26353/2025-2026:Supply and fixing12W LEDbulk head fittingheat resistant prismatic glass cover to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiringand making good the surface as required. 7 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply 8 90.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. 9 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. 10 OD26352/2025-2026:Supplying and fixing9 W LED Bulb including connection etc. as required 11 OD26360/2025-2026:Supply, Conveyance, installation, testing and commissioning of 450 mm sweep wall mounting fan with metallic blades, blade covemounting fan with blades, covers,body,mounting brackets etc (orient electric Tornado Wall-II 450mm Wall Fan Chrome/Crompton SStorm2 450mm 450 mm 3 Blade Wall Fan/Polar Blustery Wall Mounted Fan 450 mm 3 Blade Wall Fan make) and giving connections etc as required. 12 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 13 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 14 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm 15 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 16 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm 17 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 18 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 19 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 20 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface 21 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator 22 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 23 OD26354/2025-2026:Supplying and fixing FP sheet steel enclosure on surface/ recess along with 40 amps 415 volts C curve Four pole Isolator complete 24 90.11.1.10:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 25 90.11.1.15:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) 26 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 27 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 28 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 29 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 30 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 31 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 32 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 33 OD26362/2025-2026:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system 34 OD26356/2025-2026:25 mm X 3 mm G.I. strip earth lead Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate 35 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 36 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) 37 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) 38 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) 39 OD26359/2025-2026:Supply and providing 25x6mm brass nut and bolt etc. as required. 40 OD26357/2025-2026:Supply and providing12x 3mm brass nut and bolt washersetc. as required. 41 OD26358/2025-2026:12x3mm brass nut and boltSupply and providing 12x3mm brass nut and bolt etc. as required. 42 OD26349/2025-2026:Supply & installation of dust and vermin proof, Three Phase Syntax Meter Board GS-MB-6535-STD-NF and to fix KSEB meters, fuse units, CT etc and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required. 43 OD26347/2025-2026:Supplying and fixing 100A, HRC Fuse with HRC Fuse link with connections, in existing meter board 44 OD26355/2025-2026:Supplying and fixing 100 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board 45 2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N 46 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) 47 OD26350/2025-2026:Supplying and fixing of following sizes of light class PVC conduit along with accessories in surface/ recess including cutting the wall/parapetand making good the same in case of recessed conduit as required as service pipe 48 OD26348/2025-2026:Supplying andprovidingM8 Anchor bolt in wall/parapet for bimding support ofKSEB servicemain etc as required. 49 90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm 50 90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm 51 90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm 52 90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp 53 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 54 90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 55 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) 56 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) 57 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 58 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size 59 90.14.24.3:Supply & fixingthe following Power Capacitors 3 phase delta connected in positon and giving connection.3 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type suitable for direct connection to motors. 60 OD26351/2025-2026:Supply, threading ,laying and jointing of the 32 mm B class GI pipe with all required accessories in ground in he existing trench as protective covering to UG Cable 61 OD26346/2025-2026:Charges for procurement, preparation and submission of application for availing single/three phase KSEB service connection with necessary Sketch, Test and completion report, etc. including necessary liaison work as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
36.
Rural Development #10721338 Price Bid
Annual Plan-Chungathara Grama Panchayath Electrification of Chempankolli Anganavadi-S0285/26-General Electrical Work- 1 Electrical 2 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 3 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 4 OD192382/2025-2026:Supply and fixing 12W LED bulk head fitting heat resistant prismatic glass cover to wall / ceiling P.F 0.9, CRI 80, Body Material: POLY CARBONATE, Input Voltage (V): 180 to 230, Operating Temperature: Upto +45 deg;C, IP20 , THD 10 and making good the surface as required.including giving connections with required length of PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire ect as required (Bajaj/Havells/Lighting Technologies, Dewton/ Lucker/K Lite/Osram make) 5 90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell 6 19.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulationB , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unitfor speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistancemore than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: 7 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. 8 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. 9 OD192386/2025-2026:Supplying and fixing 9 W LED Bulb including connection etc. as required 10 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 11 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 12 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 13 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) 14 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface 15 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator 16 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 17 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 18 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 19 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 20 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 21 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 22 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm 23 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door 24 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 25 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps 26 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 27 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 28 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 29 OD192385/2025-2026:Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate 30 OD192379/2025-2026:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system 31 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 32 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) 33 OD192388/2025-2026:Supply and providing 25x6mm brass nut and bolt etc. as required. 34 OD192389/2025-2026:Supply and installation of dust and vermin proofSyntax Meter Board( GSMB- 4537-NF ] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required 35 OD192387/2025-2026:Supplying and fixing32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board 36 OD192384/2025-2026:Supplying and fixing32A, HRC Fuse with HRC Fuse link with connections, in existing meter board 37 OD192380/2025-2026:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc 38 OD192381/2025-2026:Supplying and fixing of suitable s sizes of single phase/three phase service connection to light class PVC conduit along with accessories in surface/ recess including cutting the wall/ground/ parapet if any and making good the same in case of recessed conduit as required as service pipe 39 OD192378/2025-2026:Supplying andProviding M8 anchor bolt hook in wall/parapet for binding supportservice wireetc as required 40 OD192383/2025-2026:Charges for procurement, preparation and submission of application for availing single/three phase KSEB service connection with necessary Sketch, Test and completion report, etc. including necessary liaison work as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
37.
Rural Development #10716546 Price Bid
Yearly Tender For Providing Of Various Types Electrical Material And Services At . Grampanchayat Bavdhan Bk , Tal . Mulshi Dist . Pune-1 Supplying And Erecting Modulartype Switch6a / 10A Isimark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 8-1-2 ) 2 Supplying And Erecting Street Light Bracket For Erection Ofsingle Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Nduly Welded As Per Specification No. 3 Providing Cement Concrete Foundation Including Excavationfor The Poles 60 Cm X 60 Cm X 1.5 M Deep In 1:3:6 Cement Concrete ( 20 X 25 Mm Stone Metal ) And 45 Cm X 45 Cm X 45 Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Approved Manner. ( For 8.5 To 9 M Poles ) ( 16-3-2 ) 4 Supplying And Erecting Street Light Bracket Made From 25Mm. Dia ‘B’Class G.I. Pipe, 0.6M. In Lengthalong With Polecap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification 5 Supplying, Tpmcb 40A To 63A In Provided Distribution Board 6 Providing Pair Of Duly Tested Rubber Hand Gloves As Per Is:4770 Suitable For Working Upto 22Kv Supply. 7 Supplying And Erecting Insulated D.P. Switch Surface Type / Flush Type 32A 240Vwith Indicator Lamp & Fuse 8 Supplying H.C. Pattern Porcelain Fuse Bridge Swith Base & Hc Type Fuse Links240v 32A 9 Supplying And Erecting Programmable Digital Almanactimer Microcontroller Based With Real Time Clock To Operate On Derived Switching “On” & Switching “Off” Street Light As Per Daily Sunset And Sunrise Respectively 10 1.25 Mm Crca Sheet Metal Enclosures With 20A. 11 Supplying Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm ( 30 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv ( 1-3-29 ) 12 Supplying And Erecting Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink 2-9-5 13 Supplying And Erectingled Street Light Fitting Suitable For 26W To 36W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink 2-9-5 14 Supplying And Erectingled Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink 2-9-5 15 Supplying And Erecting Led Flood Light Fitting Of 120W, Including Lamp, With Pf > 0.95, Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification No Fg Odf / Fls-2 16 Supplying & Laying Pvc Armoured Cable 4Core 6Sq Mm 17 Supplying & Laying Pvc Armoured Cable 4Core 10 Sq Mm 7-1-15 18 Supplying & Laying Pvc Armoured Cable 2Core 10 Sq Mm 19 Supplying & Laying Pvc Armoured Cable 4Core 16 Sq Mm 20 Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) 5-3-3 21 Supplying, Erecting & Marking Dpmcb 6 A To 32 A Bseries ( For Lighting ) 5-3-7 22 Supplying, Erecting & Marking Tpmcb 6 A To 32Amp In Provided Distribution Board 5-3-14 23 Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board 5-3-17 24 Supplying & Erecting Crimping Type Aluminium Lugs For Cable Upto 16 Sq Mm Complete 7-10-1 25 Supplying & Erecting Crimping Type Coper Lugs For Cable Upto 1.5 To 6Sq Mm Complete… 26 Supplying And Erecting Two Pole Power Contactor 250V 32A For Time Switch Complete Erected On Wooden Block / Provided Box, With Necessary Materials. 4-4-3 27 Supplying & Erecting Mains With2x1.5 Sq.Mm F.R Copperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole 1-3-3 28 Supplying And Erecting Mains With Isi Mark Wp2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg 1-4-3 29 Supplying And Erecting Mains With Isi Mark Wp2 X 2.5 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire 30 Supplying And Erecting Mains With Isi Mark Wp2 X 10.00 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire 31 25 Amp, 32 Amp Three Phase L / T Contactor 32 2.5 Sq. Mm Multistand Copper Wire 33 Insulation Tape 34 Water Proof Tape 35 Cable Joint Kit Upto 16 Sq. Mm Cable 36 Street Light Pole Box Frp 37 Cement Street Light Pole Clamp 38 M.S. Street Light Pole Clamp 39 Servicing And Primary Maintenance Of Street Light Pole 1 Visit Per Month Pole Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection. Old Light Changing & Service Wire Conection Labour Works Etc. 40 Supplying And Laying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. 41 Servicing And Primary Maintenance For Street Light Pole. 42 Light Poles Painting In Silver Colour 43 26W Led Light To 100W Led Light Repairing 44 Old Pole Shifting, Rework And Foundation Work Per Pole Etc. 45 Supply &Fixing Of Shakle Hardware With Nut Bolt 46 Supply And Installation Of Mini Feeder Pillar With Stand 47 Rcc Road Cheasling Charges With Tractor Breaker ( 1 Hours ) 48 Tree Triming For Overhead Line 49 Providing Rental Basis Hydraulic Bucket Vehicle Of Highth 13 Mtr. And Weight Capacity 200 Kg With Driver, Oprator And Disel Etc. For Per Day Basis.. 50 All Types Pole Earthings 51 110Mm 4Kg. / Cm Pvc Pipes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
38.
Rural Development #10716542 Price Bid
Yearly Tender For Providing Of Various Types Electrical Material And Services At . Grampanchayat Nanekarwadi , Tal . Khed , Dist . Pune-1 Supplying And Erecting Modulartype Switch6a / 10A Isimark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 8-1-2 ) 2 Supplying And Erecting Street Light Bracket For Erection Ofsingle Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Nduly Welded As Per Specification No. 3 Providing Cement Concrete Foundation Including Excavationfor The Poles 60 Cm X 60 Cm X 1.5 M Deep In 1:3:6 Cement Concrete ( 20 X 25 Mm Stone Metal ) And 45 Cm X 45 Cm X 45 Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Approved Manner. ( For 8.5 To 9 M Poles ) ( 16-3-2 ) 4 Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness ( 4.5 + 1.75 + 1.75M ) Length Respectively And Total 8 M Long With Pole Cap, Base Plate In Provided Foundation. ( Weight 101 Kg. ) As Per Specification No. Noh-Pl / Stp 5 Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm. Dia With 4.5 X 4.5 X 3.65 Mm Thickness ( 5 + 2 + 2M ) Length Respectively And Total 9 M Long With Pole Cap, Base Plate In Provided Foundation ( Weight 147 Kg ) As Per Specification No. Oh-Pl / Stp 6 Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia. With 4.5 X4.5 X3.65 Mm Thickness ( 5.60 + 2.7 + 2.7 M ) Length Total 11 M Long With Pole Cap, Base Plate In Provided Foundation ( Weight 175 Kg. ) As Per Specification No. . Oh-Pl / Stp 7 Supplying And Erecting Street Light Bracket Made From 25Mm. Dia ‘B’Class G.I. Pipe, 0.6M. In Lengthalong With Polecap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification 8 Supplying, Tpmcb 40A To 63A In Provided Distribution Board 9 Providing Pair Of Duly Tested Rubber Hand Gloves As Per Is:4770 Suitable For Working Upto 22Kv Supply. 10 Supplying And Erecting Insulated D.P. Switch Surface Type / Flush Type 32A 240Vwith Indicator Lamp & Fuse 11 Supplying H.C. Pattern Porcelain Fuse Bridge Swith Base & Hc Type Fuse Links240v 32A 12 Supplying And Erecting Programmable Digital Almanactimer Microcontroller Based With Real Time Clock To Operate On Derived Switching “On” & Switching “Off” Street Light As Per Daily Sunset And Sunrise Respectively 13 1.25 Mm Crca Sheet Metal Enclosures With 20A. 14 Supplying Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm ( 30 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv ( 1-3-29 ) 15 Supplying And Erecting Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink 2-9-5 16 Supplying And Erectingled Street Light Fitting Suitable For 26W To 36W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink 2-9-5 17 Supplying And Erectingled Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink 2-9-5 18 Supplying And Erecting Led Flood Light Fitting Of 120W, Including Lamp, With Pf > 0.95, Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification No Fg Odf / Fls-2 19 Supplying & Laying Pvc Armoured Cable 4Core 6Sq Mm 20 Supplying & Laying Pvc Armoured Cable 4Core 10 Sq Mm 7-1-15 21 Supplying & Laying Pvc Armoured Cable 2Core 10 Sq Mm 22 Supplying & Laying Pvc Armoured Cable 4Core 16 Sq Mm 23 Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) 5-3-3 24 Supplying, Erecting & Marking Dpmcb 6 A To 32 A Bseries ( For Lighting ) 5-3-7 25 Supplying, Erecting & Marking Tpmcb 6 A To 32Amp In Provided Distribution Board 5-3-14 26 Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board 5-3-17 27 Supplying & Erecting Crimping Type Aluminium Lugs For Cable Upto 16 Sq Mm Complete 7-10-1 28 Supplying & Erecting Crimping Type Coper Lugs For Cable Upto 1.5 To 6Sq Mm Complete… 29 Supplying And Erecting Two Pole Power Contactor 250V 32A For Time Switch Complete Erected On Wooden Block / Provided Box, With Necessary Materials. 4-4-3 30 Supplying & Erecting Mains With2x1.5 Sq.Mm F.R Copperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole 1-3-3 31 Supplying And Erecting Mains With Isi Mark Wp2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg 1-4-3 32 Supplying And Erecting Mains With Isi Mark Wp2 X 2.5 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire 33 Supplying And Erecting Mains With Isi Mark Wp2 X 10.00 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire 34 25 Amp, 32 Amp Three Phase L / T Contactor 35 2.5 Sq. Mm Multistand Copper Wire 36 Insulation Tape 37 Water Proof Tape 38 Cable Joint Kit Upto 16 Sq. Mm Cable 39 Street Light Pole Box Frp 40 Cement Street Light Pole Clamp 41 M.S. Street Light Pole Clamp 42 Servicing And Primary Maintenance Of Street Light Pole 1 Visit Per Month Pole Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection. Old Light Changing & Service Wire Conection Labour Works Etc. 43 Supplying And Laying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. 44 Servicing And Primary Maintenance For Street Light Pole. 45 Light Poles Painting In Silver Colour 46 26W Led Light To 100W Led Light Repairing 47 Old Pole Shifting, Rework And Foundation Work Per Pole Etc. 48 Supply &Fixing Of Shakle Hardware With Nut Bolt 49 Supply And Installation Of Mini Feeder Pillar With Stand 50 Rcc Road Cheasling Charges With Tractor Breaker ( 1 Hours ) 51 Tree Triming For Overhead Line 52 Supplying And Erecting Solar Panel Comprising Highefficiency Mono-Crystalline / Multi Crystalline Photovoltaic Cell 40 Wp, 12V, With Necessary Clamps And Module Frame On Existing Structure As Per Specification No 53 Supplying And Erecting Approved Makebattery With Capacity Of 12 V 40 Ah With Duty Cycle 10-12 Hrs Suitable To Charge On Pv Cell With Necessary Wiring Connections Erected In Powder Coated Protection Box With Stand And Nut Bolts As Per Specification No.Esd-Sol / Bat 4-3-17 54 Servicing And Primary Maintenance Of Solar Light Pole 1 Visit In Month Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection, Timer Working Condition And Panel Cleaning 55 Solar Light Fixture With Light 9W / 12W Aluminim Dia Casting With Charge Controller & Lithinium Battery With Auto On / Off System.. 56 Providing Rental Basis Hydraulic Bucket Vehicle Of Highth 13 Mtr. And Weight Capacity 200 Kg With Driver, Oprator And Disel Etc. For Per Day Basis.. 57 All Types Pole Earthings 58 110Mm 4Kg. / Cm Pvc Pipes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
39.
Public Administrative Department #10714170 Price Bid
Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan Civil Work For Auditorium For Nagar Parishad, Dausa, Rajasthan EARTH WORKClearing Grass and Removal of Rubbish (Maximum 150mm) by manual means and disposal at a lead of 50 metres as per MoRT&H specification clause 201. 2 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil. Upto 3.0 m depth. 3 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m. 4 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.1.1 5 In ordinary rock. Depth upto 1.5 M. 6 Add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.2.1 7 Carriage of Materials by mechanical transport including loading, unloading and stacking ::Upto 1 Km 8 Stone, boulders, gravelly materia 9 Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. 10 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). 11 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRT&H specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification including all material, labour, machinery as per clause 710.1.4 of IRC:78 and clause 2200 of MoRT&H specification. 12 CONCRETE WORK 13 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 14 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 15 REINFORCED CEMENT CONCRETE 16 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix). 17 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement :1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) 18 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 19 Reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15° upto two stories excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 20 Providing and laying upto two stories reinforced cement concrete in kerbs, steps and the like excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 21 Add extra for laying reinforced cement concrete above two stories (or 7.50 mtr height above plinth level) for every one storey or 3.00 m height or part thereof. 22 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 23 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 24 Suspended floors, roofs, landings, balconies and access platform. 25 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 26 Columns, Pillars, Piers, Abutments, Posts and Struts.22.1.5 27 Stairs, (excluding landings) except spiral-staircases. 28 Extra for shuttering in circular work (20% of respective centring and shuttering items). 29 Edges of slabs and breaks in floors and walls. Under 20 cm wide. 30 Weather shade, Chajjas, corbels etc., including edges. 31 Add extra for doing centering and shutteriing work for every additional height of 1 metre or part thereof beyond initial 7.5 metre height from plinth level. 32 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. 33 BRICK / STONE MASONERY WORK 34 Brick work with FPS bricks of class designation 75 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand). 35 Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand). 36 Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:3 (1 cement :3 coarse sand). 37 Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. 38 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand). 39 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Green / Black Above 3601 Cm2 Slabs. 40 Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work. Moulding. 41 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 42 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 43 Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles 44 Providing and fixing Motive pieces all coloures for glazed tiles laid over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete. Size 200 x 300mm. 45 P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm. 46 Providing and fixing 1st quality MAT & GLOSSY finished ceramic tiles colour such as standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the the cost of cement mortar bed 1:4) Size 300mm x 450mm. 47 Providing and fixing 1st quality ceramic glazed vitrified tiles of colour standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to IS : 13753 & IS : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete. (excluding the the cost of cement plaster on wall and pillar). Size 600mm x 1200mm 48 38mm thick wood block flooring of first class teak wood laid over 25mm thick levelling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10mm nominal size) to be paid separately coated with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping in hot bitumen (blown type) upto half depth, planed, levelled smooth and finished complete. 49 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 50 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone. 51 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 52 ROOFING 53 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75mm deep chase. 54 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80mm thick with zinc coating not less than 275gm/m². 55 Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 square decimetre 0.80 mm thick 56 Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80mm thick with zinc coating not less than 275gm/m² 57 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine/ coarse sand) 58 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand). 59 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. 60 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 61 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) toplayer 6mm thick with cement mortar 1:4 (1 cement : 4 fine sand). Design on outer plaster. 62 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 63 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. 64 Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). 65 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work. 66 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 67 Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS : 8193, density 16kg/m3 , 50mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing GI wire. 68 Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving screws, over expansion joints on vertical surfaces/ceilings with full threaded, cadmium plated steel screws 4mm dia. stem, 30mm long and aluminium washers 2mm thick, 15mm dia. at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete. Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron). 69 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width. 70 Providing and laying expansion joint complete as per drawing and technical specification and as per clause 2605 of MoRT&H Specification including all material, labour, machinary etc. 71 Fillar joint with 20m thick compressible fibre board. 72 Fillar joint with Joint sealing compound with coarse sand and 6 %bitumen by weight. 73 Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: Hot finished seamless type tubes. 74 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 75 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C 76 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. M.S. tube. 77 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 78 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure A : 30 mm thick Decorative teak veneer both side. 79 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured). Decorative teak veneer both side. 80 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) Rectangular or square. 81 Extra for cutting rebate in flush door shutters for making double leaf shutter(Total area ofthe shutter to be measured). 82 Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 50 mm long. 83 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete: 20 mm dia. 84 Providing and fixing to existing door frames. 30mm thick factory made solid both side Pre-laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded Pre-laminated PVC C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side Pre-laminated PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification & drawing (for W.C. and bathroom door shutter). 85 ALUMINIUM WORK 86 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : For fixed portion. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). 87 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron). 88 Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination on other side balancing lamination Grade I, Type II, IS : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 25 mm thick 89 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge . (Cost of aluminium snap beading shall be paid in basicitem) : With float glass panes of 5.50 mm thickness. 90 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate. 91 Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin-charge complete. 355 X 19 mm. 92 INTERIOR WORK 93 FALSE CEILING 94 Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part I, 95 Sanitary Items 96 Plumbing 97 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour. 98 15 mm nominal bore with 3 cm length. 99 15 mm nominal bore with 45 cm length. 100 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.20 mm nominal bore, 120 mm long. Weighing not less than 198 gms. 101 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 102 15 mm nominal bore 103 20 mm nominal bore 104 25 mm nominal bore 105 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 106 25 mm nominal bore Horizontal 107 25 mm nominal bore Vertical 108 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 109 Sanitary 110 Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 : Upto 300 mm dia. 111 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : 112 100 mm dia. pipe 113 125 mm diameter pipe 114 Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead : 115 100 mm diameter pipe 116 125 mm diameter pipe 117 Supplying pig lead at site of work. 118 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter 119 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 120 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With bricks with class designation 75 121 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With bricks class designation 75 122 Providing and fixing square-mouth S.W. gully trap grade A’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With bricks class designation 75. 123 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design With bricks. 124 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design With bricks 125 Fixtures 126 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. 127 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated levers. 128 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : White glazed fire clay kitchen sink of size 600x450x250 mm. 129 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 130 Rectangular shape 453x357mm 131 Rectangular shape 1500x450 mm 132 Providing and fixing 100 mm sand cast Iron grating for gully trap 133 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 134 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outlet 135 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore 136 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms. 137 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-incharge and finished smooth. Granite Stone of approved shade 138 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 139 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. 140 Internal work - Exposed on wall 15 mm dia. nominal bore 141 Internal work - Exposed on wall 20 mm dia. nominal bore 142 Internal work - Exposed on wall 25 mm dia. nominal bore 143 Internal work - Exposed on wall 32 mm dia. nominal bore 144 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia. nominal bore 145 Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 20 mm dia. nominal bore 146 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 147 15 mm dia. nominal bore 148 20 mm dia. nominal bore 149 25 mm dia. nominal bore 150 32 mm dia. nominal bore 151 Painting G.I. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work : 152 15 mm dia. nominal bore 153 20 mm dia. nominal bore 154 25 mm dia. nominal bore 155 32 mm dia. nominal bore 156 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 157 15 mm dia. nominal bore 158 20 mm dia. nominal bore 159 25 mm dia. nominal bore 160 32 mm dia. nominal bore 161 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 162 15 mm nominal bore 163 20 mm nominal bore 164 25 mm nominal bore 165 WATER HARVESTING SYSTEM 166 Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes but excluding cost of casing pipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 200 mm dia Nominal bore 167 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985 of following nominal bore sizes at site of work. 200 mm dia 168 Supply and fixing of M.S. clamp set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 169 Providing & lowering of G.I. flange pipe B Class including rubber washer and nuts of 8 mm dia complete in all respect. 50 mm dia 170 Development of tube well as per IS specification using suitable compressor to give sand free water for required yield of the gravel packed tube well. 171 ELECTRICAL G-SCHEDULE 172 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its accessories, round tiles,18 SWG M.S. box with earth terminal, 6 A switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 173 Short point (up to 3 mtr.) 174 Medium point (up to 6 mtr.) 175 Long point(up to 10 mtr..) 176 Wiring of twin control light / fan / call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its accessories, round tles,18 SWG M.S. box with earth terminal, 6 A two way switch, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 177 Short point (up to 3 mtr.) 178 Medium point (up to 6 mtr.) 179 Long point(up to 10 mtr..) 180 Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm FR PVC insulated unsheathed 1.1 kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated unsheathed 1.1 kV grade copper earth conductor (IS:694) of approved make double lock/ ISI marked single lock pvc casing capping & its accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & falce ceiling point, 6 A switch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 181 On board 182 Short point (up to 3 mtr.) 183 Medium point (up to 6 mtr.) 184 Long point(up to 10 mtr..) 185 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. 186 20 mm 187 25 mm 188 32 mm 189 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 190 3x 1.5 sq.mm 191 2 x 2.5 sq. mm. + 1x1.5sqmm 192 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 193 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 194 4 x 10.0 sq.mm 195 4 x 16.0 sq.mm 196 Supplying and drawing PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable of approved make in existingsurface or recessed conduit/casing capping including making connections as required. 197 RG - 6 198 RG -11 199 Supplying and drawing PVC/ Polythene insulated and PVC sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. Tinned / annealed copper conductor taped &confirming to ITD specification S/WS-112C &113 C of approved make in existing surface or recessed conduit/casing capping. 200 Unarmoured 2 pair 201 Unarmoured 10 pair 202 Unarmoured 20 pair 203 Unarmoured 50 pair 204 Jelly filled armoured (PIJF) 5 pair 205 Jelly filled armoured (PIJF) 10 pair 206 Jelly filled armoured (PIJF) 20 pair 207 Jelly filled armoured (PIJF) 50 pair 208 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar masking sheet conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required. Double door (Three phase) Per phase isolation 209 2+8 Way 210 2+12 Way 211 Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 212 2.5 Sq. mm 4 core 213 4.0 Sq.mm 4 core 214 6.0 Sq.mm 4 core 215 10.0 Sq.mm 4 core 216 16.0 Sq.mm 4 core 217 25.0 Sq.mm 3.5 core 218 35.0 Sq.mm 3.5 core 219 50.0 Sq.mm 3.5 core 220 70.0 Sq,mm 3.5 core 221 95.0 Sq.mm 3.5 core 222 120.0 Sq.mm 3.5 core 223 150.0 Sq.mm 3.5 core 224 240.0 Sq.mm 3.5 core 225 300.0 Sq.mm 3.5 core 226 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 227 3.5 x 25.0 sq.mm 228 3.5 x 35.0 sq.mm 229 3.5 x 50.0 sq.mm 230 3.5 x 70.0 sq.mm 231 3.5 x 95.0 sq.mm 232 3.5 x 120.0 sq.mm 233 3.5 x 150.0 sq.mm 234 3.5 x 240.0 sq.mm 235 3.5 x 300.0 sq.mm 236 4 x 2.5 sq.mm 237 4 x 4.0 sq.mm 238 4 x 6.0 sq.mm 239 4 x 10.0 sq.mm 240 4 x 16.0 sq.mm 241 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. Hot Dipped Galvanized. 242 150mm x 50mm x 1.6mm 243 300mm x 50mm x 1.6mm 244 450mm x 50mm x 2.0mm 245 600mm x 50mm x 2.0mm 246 Maintenance free gel earthing with pipe in pipe /Strip in Pipe technology filled with anti corrosive conductive compound (CPRI tested) below the ground in 150 -200 mm dia earth pit and surrounding filled with required mineral filling compound (MFC should have hygroscopic proper ty to retain the moisture for long time to create low resistance Zone) and C.C. finished chamber covered with hinge type with locking arrangement C.I cover. C.I. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes With pipe in pipe technology (inner pipe dia / outer pipe dia) 80 -100 micron G.I. coating With pipe in pipe technology with 80-100 micron G.I. coating G.I. pipe 3000 mm long , 80/40 mm , terminal 14 mm G.I. strip 247 S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 248 8 SWG copper Wire 249 25mm x 3mm copper strip 250 50mm x 6mm copper strip 251 25mm x 3mm G.I. ( Hot Dipped) Strip 252 25mm x 6mm G.I. ( Hot Dipped) Strip 253 P & F of IP20 LED Recessed/ Surface Mounted Round/ sqaure Non Dimmable Downlight with die-cast aluminum housing & Heat sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. ( supplied together with luminaire) Power consumption of =< 7w/10w/8w/12w/15w/18W with 100/500/750/1100/1250 lumens, system lumen, efficeancy of 70 lm / Watt or 100 lm / Watt output suitable to replace 1x18W/ 2x18w/2x26w CFL downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE Compliance. 254 Recessed mounting LED Downlight 18/20W 255 Surface Mounting LED Downlight 18/20W 256 P & F of IP20 LED Ceiling/ Recessed/ suspended mounting light fixture made form CRCA sheet steel housing, high purity/ transmisivity diffuser for uniform light distrubution.High efficiency driver electronics having efficiency > 85% and in compliance to IEC standards.(integral driver). Power consumption of 40 W/50W/60W, 3000/3300/4200 lumens, system lumen efficiency of 70-80 lm / Watt output suitable for 2x36W FTL/ 2x36w CFL/3x36w CFL light fixtures, life time of 50000 burning Hours with 70% intial Lumens maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be CE compliance. Surface Mounting 36W LED Light 2’x2’ with acrylic/ prismatic front cover 257 P & F energy efficient direct fit (Retrofit) LED tube system (with integral driver), on existing fixture. Power Consumption of18W / 36W 1500-3000 lumens, system lumen efficiency 80 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K& 6000°K. 4 LED Tube shape fixture 18W. 258 P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance. IP-65 protected LED street light luminaries LED street light fixture 150 watt 259 Supply and erection of Octagonal pole of following length and dimension as per table-3 with base plate on the cement concrete foundation of M-15 /M-20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (IS 1367 P III ). The pole shall be made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. The pole shall have a weatherproof flush door and locking arrangements. The complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. 9 Mtr. 260 Supply, Installation, Testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer (+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5% of the maximum total loss values for 11 KV as per energy efficiency level - 2 at basic Insulation level conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. Transformers described as above and as per the following continuous rating. 315KVA 261 Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 11 KV Incomer VCB panel up to 630 A equipped with following switchgears and accessories designed & tested as per latest standard i.e. IEC 62271-200, suitable for STC 25KA/3 and IAC A-FLR for 25kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make. 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-12 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer, Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core dual ratio 3CTs of suitable ratio with sec 1 of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter. 262 SITC of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.Alternator shall be self regulated with standard Alternator Protection( Over voltage, over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping , electronic / Mechanical governor, Manual & electric Start, Batteries, Fuel tank ( with Stand) & piping, control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet and filled with foam as per CPCB norms latest amendments & IS 8183 .The doors are fabricated from 1.6 mm CRCA sheet packed with accoustic material, floor of MS chequrred plate 5.0 mmthick, All doors/ opening are sealed with neoprene/ EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 °C. All controls for operation of DG set are from outside the enclosure with DG control panel having microprocessor based genset monitoring and control system mccb Ammeter, voltmeter, Pf meter, frequency meter, KWH meter, Ind. Lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 75 db (A) at a distance of 1 Mtrs. duly certified by authorized agency. Complete in all respect of following capacity : Radiator cooled and turbo charged 250 KVA at 0.8 pf 415V 50Hz 3-?. 263 Supply, Installation, Testing & Commissioning of HT metering cubical panel as approved By DISCOMs fabricated out of 14 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX6mm having provision for Following: (i) Provision for fixing Trivector Meter (To be supplied by DISCOMs) (ii) Provision for fixing of combined CT PT Set (To be supplied by DISCOMs) (iii)TT Block (iv) 6mm Bakelite sheet on all sides. 264 Supply, Installation, testing and commissioning of 11 KV Double Pole structure With Air Break SWITCH having following specifications : (a) DP : Double pole structure made of two nos. 9 meter long PCC poles (400 Kg) & 7 nos. MS Channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per REC standards in all respect with nuts, springs washers, clamps as required. (b) GO:Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3 phase, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 Nos pin insulator ,GI pipe of suitable length for operation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Post insulators. (c) DO: 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators (d) LA:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. (e) JUMPERS: 3 no 11kv acsr conductors mounted on pin type insularors as required. GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ 265 FIRE ALARM G-SCHEDULE 266 SITC of microprocessor based 2 - wire loop (each loop accessing 90 addressable units ) Fire Alarm Control Panel. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. The Panel shall also be able to give voice announcement to individualized speakers. The Panel shall have built in sounder, Maintenance Free Batteries of minimum 15 Ah of 24 volts capable of minimum of 12 hours with battery charger, rectifier. Loop cards, LCD unit to indicate Fire / Fault Signal of individual unit, built in-built / external printer, to log all incoming data etc complete in all respect. 2-LOOP. 267 SITC Manual Call Point complete with , Glass, hammer and chain etc as required: Analogue addressable type 268 SITC Automatic commendable Control Switches for shutting downAC Plant, Power Supply, Gas Supply etc. Response Indicators. 269 SITC Fault Isolators for isolating shorted, dead wire and loose circuits between two successive Fault Isolators with automatic resetting arrangement. Analogue addressable type. 270 FIRE FIGHTING G-SCHEDULE 271 Sub Head - I - (Wet Riser System - Pumping Equipments)SITC of electric driven Sprinkler / Hydrant pump Suitable for automatic Operation consisting of the following-(A) Horizontal multi stage Centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary sluice value on the suction side ( all items to be matching the suction side of the pump) and pressure gauge sluice value and non return valve on the delivery side side ( all of the necessary dia) and including bypass arrangement for testing of pump.(B) Squirrel cage induction motor suitable for 415 V, 50 HZ, Ac supply of below mentioned HP for the above pump ,1450 RPM T.E.F.C confirming to IP:55 and flexible coupling and coupling guard with the pump. (C) Common bed plate fabricated from mild steel channel or cast iron type1620 LPM at 70 Mtr Head ( 50 HP Motor) 272 SITC of diesel engine drive Standby Pump suitable for automatic operation consisting of the following A, B, C. .The Diesel driven pump shall be suitable for following discharge:(A) Horizontal multi stage centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, sluice value on the suction side (all items shall be matching the suction side of the pump) and pressure gauge, sluice valve and non return valve on the delivery side (all of the necessary dia) and including bypass arrangement for testing of pump.(B) Water cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump, d cushy foot, damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically with a unit of battery of 12/24v, 88 Ah, 13/21 plate, Exhaust Pipe of minimum 10 M length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumpingset, Supply, installation, testing, & commissioning of electric driven automatic pressurization pump setC) Horizontally mounted single stage centrifugal end delivery pump of below mentioned discharge with necessary sluice valve on the suction side (all items matching the suction side of the pump) and sluice valve, non return value, pressure gauge on the delivery side including by pass arrangement for testing of the working of the pumping set as required.1620 LPM at 70 Mtr Head ( 50 HP Engine) 273 SITC of Jockey pump having Squirrel cage induction motor suitable for 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM T.E.F.C type confirming to IP:55 and flexible coupling and coupling guard with the pump ,Common bed plate of fabricated mild steel channel or cast iron type. 180 LPM at 70 Mtr (15 HP). 274 Supplying & Installing cylindrical type air vessel, 250 mm dia 1.5M high of thickness 6.0 mm M.S. complete with air release valve, safety valve, pressure gauge etc.along with two coats of Red Oxide and two coat of post office red enamel paint as required. 275 Providing & fixing 100mm dia pressure Gauge on Pump DeliveryLine complete with shut off cock. 276 SITC of pressure switches for Main, Jockey, and standby pumps,including necessary wiring UPTO control panel and stop valve. 277 Sub Head - II - (Hydrants System) 278 Providing and fixing single headed hydrant valves with flanged inletISI marked with 63 mm female instantaneous outlet of gun metalcomplete with blank cap and chain conforming to IS : 5290 279 Providing . 63 mm dia 15 M long reinforced rubber hose pipeconforming to IS : 636-1962, Part –A & ISI marked with Gun Metalmale & female coupling wire wound with the pipe. 280 Providing & fixing (1.0 M x .45 M x 0.6 M ) OUTDOOR HOSECABINET suitable for accommodating hydrants made of not lessthan 16 swg. M. S. sheet having central opening glazed doorincluding necessary locking arrangement, painting (one coat primer& two coats of paint ) and housing 2 Nos. RRL hose pipe, 1 Nobranch pipe. 281 Providing and fixing Swinging Drum type hose reel ISI marked 30M(L) x 20 mm (dia) rubber lined pipe with shut off nozzle of 6 mm diaincluding the cost of 25 mm dia pipe connection from riser to hosereel , all sockets, nipples, elbows and 25 mm globe valve. 282 Providing and fixing ISI marked Three Way fire Brigade Inlet to wetRiser with non return valve complete in all respects 283 Providing, fixing, jointing and testing of Heavy Gauge (C class ) MSPipe ISI marked with accessories like tees, elbows, flanged joints,reducers, compressed asbestos gaskets, nuts and bolts includingfixing the pipe with suitable flat iron strip clamps /bracket, paintingetc. Complete as required for delivery/ suction manifold relating tothe pump including painting of two coats of Red Oxide and two coatof post office red enamel paint including all civil breakages andmaking good the same : 284 200mm dia 285 150 mm dia 286 80 mm dia 287 Sub Head - III - (Piping, Valves and Accessories) 288 MS (Medium duty B class) pipe with cleaning,wrapping and coatingof the pipe as per IS; 10221 in all kind of soil at 1.0 M depthincluding excavation as required. 289 150 mm dia 290 100 mm dia 291 80 mm dia 292 Providing & fixing Butterfly valve with Cast Iron Body, Cast Iron Discand Seat of Nitrile Rubber Bonded on Bakelite with hard back to PN1.6 rating with following sizes complete with bolts, washers andcompressed asbestos gasket as required 293 150 mm dia 294 100 mm dia 295 80 mm dia 296 Providing and fixing non return valve complete with bolts nuts washers and compressed asbestos gasket etc as required : 297 200 mm dia 298 150 mm dia 299 80 mm dia 300 Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5kg capacity. 301 Providing, fixing, testing & commissioning of sprinkler heads of thefollowing type : Pendant type with quartziod bulb, operating temperature at 68 deg Cas per specifications. 302 Providing & fixing 10 SWG chrome plated brass 100 mm diadecorative flanges / escutcheon plates to be fixed at junction ofSprinkler piping with the false ceiling. 303 Sub Head - III - (Piping, Valves and Accessories) 304 Sub Head - IV (Fire Electrical Control Panel) 305 Supplying and making end termination with heavy copper lugs (pin/ring type) duty crimped with crimping tool, PVC tape etc of followingsize 306 1.5 Sq.mm 307 10.0 Sq.mm 308 35.0 Sq.mm 309 Supply, Fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. 100mm x 50mm x 1.6mm 310 BOUNDARY WALL G-SCHEDULE 311 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 312 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 313 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 314 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) 315 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-30 Grade Concrete. 316 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 317 Lintels, beams, plinth beams, girders, bressumers and cantilevers. 318 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars 319 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing. 320 Random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of MoRT&H specification including all scaffolding material, labour, machinery but excluding pointing and plastering. In cement mortar 1:4 (1 cement : 4 coarse sand) 321 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 322 EARTH WORK 323 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 324 Earth work in excavation in open area, STP, WTP, Pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of Engineer. (Measurements for payment to be done as per standard drawings). In all type of soil Upto 3.0 m depth. 325 EXTERNAL DEVELOPMENT 326 Compacting original ground 327 Loosening upto a level of 500 mm below the subgrade level watered, graded and compacted in layers by vibratory roller 8-10 tonne to meet requirement of table 300-2 for subgrade construction as per MoRT&H specification clause 305.3.4. 328 Loosening and recompacting original ground below embankment including Loosening leveling and recompacting original ground supporting embankment to facilitate placement of of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling by vibratory roller 8-10 tonne so as to achieve minimum dry density as given in table 300-2 for embankment construction as per MoRT&H specification clause 305.3.4. 329 Providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (WMM) base course comprising of graded stone aggregate and granular material conforming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each consolidated, including pre-mixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/ base course and compacting with power vibratory-roller to achieve the desired density complete as per MoRT&H specification clause - 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 330 CEMENT CONCRETE PAVEMENTS 331 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid manualy, compacting with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 332 Providing and laying un-reinforced, dowel jointed, plain cement concrete mix With Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. PCC M-30. 333 Providing and laying cast-in-situ cement concrete M-20 grade kerb stone channel top and bottom width 115 and 165 mm respectively, 250mm high laid with kerb laying machine, on 150 mm thick PCC M10 grade foundation (laid manually) as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. Using Concrete Mixer. 334 Providing and fixing of 60mm thick precast cement concrete interlocking paver block casted with rubber moulds in approved reflective colour and design having minimun compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. 335 Flooring with Cobble stone of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3 ( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of Engineer-in-charge. 336 Providing at site, lowering & laying in trenches, aligning & jointing of RCC pipes NP4 class (with s/s ends) IS: 458 - 2003 (amended up to date) marked and pipes from 300 mm and upto 1800 mm manufactured through vertical casting process at all depths with Rubber gaskets (EPDM/SBR) for sewer lines as per IS: 5382 (including cost of Rubber gaskets, lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as per specification and / or as directed by Engineer. Note : E/w to be measured and paid separately. 300 mm internal diameter. 337 Horticulture Work 338 Grassing with Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 7.5 cm apart in either direction. 339 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 340 Ficus panda 341 Tecoma capensis ( Ratanjot) 342 Clerodendron inermii ( Choti Aari) 343 Tabernaemontana variegated ( Chandni) 344 Hamelia patens ( Firebush, Thal Kamal) 345 Hibiscus variegated ( Guddal) 346 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes, 0.3 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 347 Wedelia trilobata ( SunFlower Family) 348 Alternathera green (Parrot Leaf) 349 Iresine herbstii (Blood Leaf) 350 Ophiopogon Black ( Lily Turf, Mondograss) 351 Asparagus myerii (Fox Tail) 352 Lantana sellowiana 353 Rhoeo spathacea Compacta‘ ( Oyster, Boat Lily) 354 Golden duranta 355 Pennisetum setaceum (Fountain Grass)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
40.
Drinking Water Supply and Sanitation #10713558 Price Bid
Different Works Related To Water Supply Scheme At Duna & Its Adjoining Mouzas Water Supply Scheme Within Mayureswar-Ii Block Including Supply Of All Labour & Materials Underbirbhum Division, Phe Dte. ( Sl. No.11 ) - Sinking Of Tubewell- 3 Nos. ( Annexure I ) Site Preparation, Temporary Latrine, Placement & Levelling Of Rig Machine, Mast Hoisting And Casing Drilling ( Upto 6 Mtr. ) Placement Of Casing With All Allied Works Necessary To Commence Drilling Woks And Wind Up Of All Machineries After Completion Of Drilling. 2 Drilling By Direct Rotary Method Of Drilling Using9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Includingcost Of Fuels And Lubricants Etc. As Required For Drilling.Note:1 ) Rate Only For Pilot Drilling Will Be @ 50%. Of Item Rate.2 ) Ratefor Reaming By 12 1 / 4 Dia. Bit Will Be @ 14% Of Item Rate.3 ) Ratefor Reaming By 15 Dia. Bit Will Be @ 16% Of Item Rate.4 ) Ratefor Reaming By 17.5 Dia. Bit Will Be @ 20% Of Item Rate. From 6 Mtr. To 60 Mtr. 3 From 60 Mtr. To 90 Mtr. 4 From 90 Mtr. To 120 Mtr. 5 From 120 Mtr. To 150 Mtr. 6 From 150 Mtr. To 180 Mtr. 7 Lowering The Tube Well Assembly ( Upvc Casing Pipe , Well Pipe, Strainer Along With Upvc Accessories ) Vertically In A Position With Proper Lowering Arrangement By Applying Necessary Jointing Compound Including Labour Cost For Subsequent Gravel Packing And Machine Operation Cost Etc. 8 Cost Of Consumables For Drilling Rigs And Machineries. 9 Development ( Min. 8 Hr. Continuous ) Of Tube Well By Using Suitable Air Compressor ( Min. Capacity: 600Cfm & Operating Pressure 14 Bar ) Followed By Yield Testing With Bht Pump ( Head :45 To 50Mtr., Discharge :1100 To 1000 Lpm And 25 Bhp Engine ) All Complete Includingto & Fro Transportation Cost And Cost Of Fuels, Lubricants & Labour Etc. 10 Water Sample Collection And Chemical Test Including Arsenic Test. 11 Transportation Cost Of Drilling Equipmentand Accessories Rig Machine Etc. Including Cost Of Fuel, Lubricant & Loading Unloadingthe Materials From Store / Stack Yard / Suppliers Godown And Unloading / Stacking The Same At Site. ( Upto 60.0 Km Distance ) 12 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) . ( 250 Mm Dia. ) 13 Supply And Delivery Of Upvc Pipe ( Cd ) Conforming To Is 12818:2010. ( Cipet Certified ) . ( 150 Mm Dia. ) 14 Supply And Delivery Of Upvcdeep Well Screen ( Rds ) Pipes With Ribs Conforming To Is 12818:2010 . ( Cipet Certified ) 150 Mm Dia. 15 Supply And Delivery Ofupvcreducer 250Mm X 150Mm Dia. 16 Supply And Delivery At Site Of Upvc End Cap. ( 250 Mm Dia. ) 17 Supply And Delivery At Site Of Upvc End Cap. ( 150 Mm Dia. ) 18 Supply And Delivery Of M.S. Housing Clamp 250 Mm Dia. 19 Supply And Delivery Of M.S .Centre Guide ( Special Type ) . 20 Supply And Delivery Of Washed Gravels Size Ranging From 1.80 Mm To 4.74 Mm. Conforming To Is 4097 : 1967. 21 Supply And Delivery Of Bentonite Powder Conforming To Is 6186 : 1986. 22 Electro-Logging Charge. 23 Trial Boring Of Tube-Welldrilling By Reverse Rotary Method Of Drilling Using9 7 / 8” Dia.Bit For Pilot Bore Follwed By Subsequently Reaming Using 12 1 / 4” Dia. , 15 Dia. And 17.5 Dia. Rock Roller Bits / Drag Bits In Consolidated, Semi Consolidated And Soft Formation Up To Required Depth Including Casing Boring And Casing Lowering As Required Includingcost Of Fuels And Lubricants Etc. As Required For Drilling.Note:1 ) Rate Only For Pilot Drilling Will Be @ 50%. Of Item Rate.2 ) Rate For Reaming By 12 1 / 4 Dia. Bit Will Be @ 14% Of Item Rate.3 ) Rate For Reaming By 15 Dia. Bit Will Be @ 16% Of Item Rate.4 ) Rate For Reaming By 17.5 Dia. Bit Will Be @ 20% Of Item Rate.From G.L. To 60 Mtr. 24 From 60 Mtr. To 90 Mtr. 25 From 90 Mtr. To 120 Mtr. 26 From 120 Mtr. To 150 Mtr. 27 From 150 Mtr. To 180 Mtr. 28 Cleaning Compound Premises Of Shrubs, Plants, Jungled Etc. As Per Direction Of E.I.C. 29 Soil Test For Ohr- 1 No. ( Annexure Ii ) Mobilisation Charges Of All Tools & Plants Along With Accessories, Material, Labour, Supervision Etc. At Site Of Work Required In Connection With Boring And Testing Work, Including Setting Up Boring Rigs And Shifting To Different Bore-Hole Points Etc. And Also Including Withdrawal Of Same From The Site After Completion Of Work, Complete As Per Direction Of Engineer-In-Charge. 30 Labour For Making Bore-Holes Of 150Mm To 250Mm Dia. By Any Standard Method To Any Depth Below Ground Level / Bed Level In All Kinds Of Soil Like Clay, Silt, Sand, Stiff Clay, Mixed Soils Etc. Except Rocks ( For The Purpose Of Collecting Disturbed & Un Disturbed Soil Samples, Conducting Standard Penetration Test At Suitable Intervals Etc. ) Including Preparation And Submission Of Bore-Log As Per Irc : 75 And 78 And Clause 2400 Of Specifications For Road & Bridge Works ( 5Th Revision ) , Published By Irc, And Also Including Hire Charges Of Tools And Plants Complete As Per The Direction Of Engineer-In-Charge.A ) When Casing Pipe Is Used To Prevent Collapse Of Bore Hole ( Casing Pipe To Be Finally Withdrawn ) I ) Depth 0 M To 10 M ( For 3 Nos Bore ) 31 Ii ) Depth Greater Than 10 M & Upto 20 M 32 Iii ) Depth Greater Than 20 M & Upto 30 M 33 Field Investigation :I ) Collection Of Undisturbed Soil Sample From The Bore Hole To Be Made By The Concerned Division / Party At Their Cost.A ) 0.00 - 10.0 M 34 B ) 10.00 - 20.0 M 35 C ) 20.00 - 30.0 M 36 Ii ) Collection Of Samples From The Bore Hole ( A ) Disturbed 37 Iii ) Standard Penetration Tests ( S.P.T. ) By Split Spoon Sampler In The Bore Hole As Per Is : 2131.A ) 0.00 - 10.0 M 38 B ) 10.00 - 20.0 M 39 C ) 20.00 - 30.0 M 40 Laboratory Investigation :I ) Liquid Limit As Per Is 2720 ( Part – V ) . 41 Ii ) Plastic Limit As Per Is 2720 ( Part – V ) 42 Iii ) Grain Size Analysis By Sieving As Per Is 2720 ( Part – Iv ) . 43 Iv ) Grain Size Analysis By Hydrometer Method As Per Is 2720 ( Part – Iv ) . 44 V ) Determination Of Water Content As Per Is 2720 ( Part – Ii ) . 45 Vi ) Determination Of Specific Gravity As Per Is 2720 ( Part – Iii ) . 46 Vii ) Direct Shear Test As Per Is 2720 ( Part – Xiii ) . 47 Viii ) Determination Of Unconfined Compressive Strength As Per Is 2720 ( Part-X ) ( I ) Undisturbed 48 Ix ) Determination Of Consolidation Properties As Per Is 2720 ( Part – Xiv ) . 49 X ) Tri-Axial Shear Test :A ) Determination Of Shear Strength Parameters Of A Specimen Tested Inunconsolidated Undrained Tri-Axial Compression Without Measurement Ofpore Water Pressure As Per Is 2720 ( Part –Xi ) . 50 Carriage Of All Disturbed & Undisturbed Samples From Site Of Work To The Divisional Office Or Elsewhere Including Loading And Unloading As Per Direction Of Engineer-In-Charge. Detailed Investigation. 51 Preparation And Submission Of Report In 6 ( Six ) Copies, Giving All Relevant Information Data Like Site Plan, Bore Log And Water Table, Test Results, Calculations, Discussions, Suggestions And Recommendations In Respect Of Suitable Foundation Etc. Including Determination Of Silt Factor Calculation Of Waterways And Complete Design Of Foundation Including Analysis Of Bearing Capacities And Settlements In Bound And Presentable Form Complete As Per Direction Of Engineer-In-Charge.Detailed Investigation. 52 Construction Of 300 Cum Ohr- 1 No. ( Annexure Iii ) Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete. A ) Depth Of Excavation Not Exceeding 1500 Mm 53 B ) Depth Of Excavation For Additional Depth Beyond 1500Mm And Upto 3000Mm. ( But Not Requiring Shoring ) . 54 Bailing Out Water From Foundation Trench. This Item Should Be Executed On The Specific Direction Of The Engineer-In-Charges When He Is Satisfied In His Absolute Discretion, That This Has Not Been Necessitated Due To Any Fault On The Part Of The Contractor ) 55 Hire And Labour Charges For Shoring Work ( Including Necessary Close Plank Walling, Framing, Eucalyptus / Jhau Balla Pilling, Strutting Etc ) Complete As Per Directionof The Engineer-In-Charge For Foundation Excavation ( Vertical Surface Are In Contact With Supported Earth Is To Be Measured. ) ( This Item Should Be Executed On Specific Direction Of The Engineer-In-Charge ) .A ) Depth Upto 1.5M. 56 B ) For Additional Depth Beyond 1.5M And Upto 3.00M. 57 Earth Filling In Foundation Trenches Or Plinth With Good Earth In Lyres Not Exceeding 150Mm Including Watering & Ramming Etc Layer By Layer Complete.A ) With Earth Obtained From Excavation Of Foundation. 58 Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm As Directed And Consolidating The Same By Thorough Saturation With Water, Ramming Complete Including The Cost Of Supply Of Sand. ( Payment To Be Made On Measurement Of Finished Quantity ) Do - By Fine Sand 59 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming And Dressing Bed To Proper Level, And Filling Joints With Powered Earth Or Local Sand. 60 Cement Concrete With Graded Stone Chips ( 20Mm Size ) Excluding Shuttering, In Ground Floor ) Considering 30 Km Distance From Suri Rly. Yard.A ) 1:2:4 Proportion. ( In Foundation And Under Tank At Finished Gl, Plinth Protection Etc. ) 61 Controlled Cement Concrete With Well Graded Stone Chips ( 20Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per I.S.456 And Relevant Special Publications, Submission Of Jobs Mix Formula After Preliminary Mix Design After Testing Of Concrete Cubes As Per Direction Of Eic. Consumption Of Cement Concrete Will Not Be Less Than 300Kg Of Cement With Super Plasticizer Per Cubic Meter Of Controlled Concrete But Actual Consumption Will Be Determined On The Basis Of Preliminary Test And Job Mix Formula. ( Using Concrete Mixture ) .Considering 60 Km Distance From Suri Rly. Yardm- 25 Grade ( With Pakur Variety. ) A ) For Works In Foundation, Basement And Upto Roof Of Ground Floor / Upto 4M. 62 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 63 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 64 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 65 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 66 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Bottom Of Heal Beam 67 Controlled Cement Concrete With Well Graded Stone Chips ( 20Mm Nominal Size ) Excluding Shuttering & Reinforcement With Complete Design Of Concrete As Per I.S.456 And Relevant Special Publications, Submission Of Jobs Mix Formula After Preliminary Mix Design After Testing Of Concrete Cubes As Per Direction Of Eic. Consumption Of Cement Concrete Will Not Be Less Than 300Kg Of Cement With Super Plasticizer Per Cubic Meter Of Controlled Concrete But Actual Consumption Will Be Determined On The Basis Of Preliminary Test And Job Mix Formula. ( Using Concrete Mixture ) . Considering 60 Km Distance From Suri Rly. Yardm- 30 Grade ( With Pakur Variety. ) A ) Heal Beam And Above ( Cell Wall, Floor, Top & Bottom Ring Beam, Heal Beam ) A ) 6Th Floor 68 B ) 7Th Floor 69 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4M Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness And Required Bracing For Concrete Slabs, Beams, Column Lintel Curved Or Straight Including Fitting, Fixing And Striking Out After Completion Of Woks ( Upto Roof Of Ground Floor ) .Steel Shuttering Or 9 To 12Mm Thick Approved Quality Ply Board Shuttering In Any Concrete Work.C ) For Foundation Upto G.L. 70 Hire And Labour Charges For Shuttering For Concrete Work In Overhead R.C. Reservoir On Separate R.C. Frame Including Fitting, Fixing And Striking Off After Completion Of Work Including Staging Upto 4M Using Ply Board Or Steel Shuttering. ( Not Applicable For Resting On Roof Top ) .A ) G.L. To Top Lantern Of Ohr. 71 Hire And Labour Charges For Staging Beyond 4M With Necessary Cross Bracing And Fixtures And Removing The Same After Completion Of The Work All Complete As Per Direction Of The E.I.C. [ Mode Of Measurement :Area Of Unsupported Horizontal Projection ( Where Staging Beyond 4M Is Practically Un-Avoidable ) X Mean Height Of Staging ] Above Initial 4M. ( Dia 10.50 M. Mean Height 16M. ) 72 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc. , Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Inter-Section, Complete As Per Drawing And Direction. I ) Tor Steel / Mild Steeli. Sail / Tata / Rinl A ) For Works In Foundation Basement Upto Roof Of Ground Floor / Upto 4 M . 73 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 74 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 75 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 76 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 77 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Top Of Heal Beam 78 G ) 6Th Floor I.E. From Top Of Heal Beam To Top Ofshell Wall 79 H ) 7Th Floori.E. From Top Of Shell Wall To Rest 80 Applying 2 ( Two ) Coats Of Bonding Agent With Synthetic Multi Funtional Rubber Emulsion Having Adhesive And Water Proofing Properties By Making With Water In Proportion ( 1 Bonding Agent : 4 Water : 6 Cement ) As Per ManufacturerS Specification. 81 Extra Rate For Using Water Proofing And Plastering Admixture @ 0.2%By Weight Of Cement ( Or At ManufacturerS Specified Rate For Concrete Of Various Grades ) . 82 Supplying, Fitting, Fixing Fly / Mosquito Proof Nylon Net On Any Type Of Window, Doorshutter Frame With Necessary Fixing Arrangements Complete. 83 Supplying Fitting And Fixing Door Made With Irc Febric Mesh Of 75Mm X50mmx4.5Mmx2.7Mm On 50Mm X 50Mm X 6Mm Angle Iron Frames All Round And One 37.5Mm X 6Mm M.S. Flat Bar Over The Netting All Round Welded To Angle Iron Frame And Providing Locking Arrangements If Necessary And With Two Coats Of Synthetic Enamel Paint ( Other Than Hi-Gloss ) Fitted And Fixed With Clamps Or Haskal Doomney Etc. Complete At The Lantern Of R.C.C. Over Head Reservoir. 84 Artificial Stone In Floor, Dado, Staircase Etc. With Cement Concrete ( 1:2:4 ) With Stone Chips, Laid In Panels As Directed With Topping Made With Ordinary Or White Cement ( As Necessary ) And Marble Dust In Proportion ( 1:2 ) Including Smooth Finishing And Rouding Off Corners And Including Raking Out Joints Or Roughening Of Concrete Surface Andapplication Of Cement Slurry Before Flooring Works, Using Cement @ 1.75 Kg / Sq.M. All Complete Including All Materials And Labour.In Ground Floor 3 Mm Thick Topping ( High ) Polishing, Grinding On This Item Is Not Permitted With Ordinary Cement ) .25 Mm Thick.A ) In G.F For Plinth Protection And Under Tank Floor 85 B ) 6Th Floor 86 C ) 7Th Floor 87 M.S. Structural Works In Columns, Beams Etc. With Simple Rolled Structural Members ( E.G. Joists, Angle, Channel Sections Conforming To Is: 226, Is: 808 & Sp ( 6 ) - 1964 Connected To One Another With Bracket, Gussets, Cleats As Per Design, Direction Of Engineer-In Charge Complete Including Cutting To Requisite Shape And Length, Fabrication With Necessary Bolting, Metal Arc Welding Conforming To Is: 816- 1969 & Is: 1995 Using Electrodes Of Approved Make And Brand Conforming To Is:814- 2004, Haulage, Hoisting And Erection All Complete. The Rate Includes The Cost Of Rolled Steel Section, Consumables Such As Electrodes, Gas And Hire Charge Of All Tools And Plants And Labour Required For The Work Including All Incidental Chages Such As Electricity Charges, Labour Insurance Charges Etc. Payment To Be Made On The Basis Of Calculated Weight Of Structural Members Only In Finished Work As Per Is Specified Weight. Payment For Gusset, Bracket, Cleat, Rivets, Bolts And Nuts May Be Make By Adding The Actual Weight Of Such Items With The Weight Of Finished Structural Members Or 7% Of Weight For Finished Structural Members Weighing Not Less Than 22.5 Kg. / M. Or 15 % Of Weight For Finished Structal Members Weighing Less Than 22.5 Kg. / M. May Be Increased Allow For Bracket, Cleat, Rivet, Bolts And Nuts Etc. And No Seperate Payment Being Made For These Items, As Per Direction Of Engineer In Charge. The Rates Are Considered For A Height Of Erection 8M. / 2Nd Floor Level From The Ground. Add 1.5% Extra Over The Rate For Each Additional Floor Or 4M. Beyond Initiial 8M. Or Part Thereof.Iii ) For Built Up Sections / Srtuctural Members Of Specified Sections Weighing Not Less Than 22.5 Kg. / M 88 M.S. Gate Of Jail Type As Per Approved Design Made Of Strong M.S. Frame Work, Intermediate Stiffeners And Round / Square Bars Or Angles. M.S. Sheet ( Not Less Than 14 Gauge ) Gussets, Cleats Etc. Including Necessary Riveting, Bolting, Welding, Locking And Hanging Arrangements, Fitting And Fixing Complete As Per Direction Of The Engineer-In -Charge. 89 M.S. Or W.I. Ornamental Grill Of Approved Design, Joints Continuously Welded With M.S. Wi Flats And Bats For Winding, Drilling Etc.Fitted & Fixedwith Necessary Screw And Lugs In Ground Floor.A ) Grill Weighing Above 10 Kg / Sqm Upto 16 Kg / Sqm ( In Kg ) 90 Supplying, Fitting, Fixing900 Mm High G.I. Pipe Railing For R.C.C Stair Cat Ladder Walk Way Fabrication, Erection, Welding Of 40 Mm G.I ( Non Tata Medium ) Pipe Place At Top Of Railingand2 Nos 25 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed Equally In Between Railingtop & Floor, Vertical Post Of Raillingare 40 Mm Dia. G.I Pipe ( Non Tata Medium ) Placed At 900 Mm C / C . The Each End Of The Vertical Post Is Join By The 62 Mm ( 25 Mm X 6 Mm X 0.062 M Long ) Ms Flat And 150 Mm Length ( Propes Pipes ) Are Grouted In Concrete Base Of Stair, Walk Way Etc. All Complete With Supplying Of All Materials Including Hoisting Up To The Any Height Complete With 2 Coats Of Painting With Super Gloss ( Hi Gloss ) In Any Shade Except White And Black Over A Coat Of Primer Complete As Per Direction Of E.I.C.Analysis Of Rate Enclosed In Seperate Sheets. ( Analysis Rate ) 91 Supplying At Site Hoisting, Fitting, Fixing Erecting And Building In Position Where Necessary 450Mm.Wide Ladder As Per Design Consisting Of 2Nos. M.S.Plate Of 8Mm.Thick With Necessary Base Plate 60Mm Wide; And 16Mm.Dia M.S.Round Or Square Bar As Steeps Placed @ 300 C / C Including Fabrication, Welding Drilling Etc. As Per Drawing And Direction And Finished With Two Coats Of Synthetic Enamel Painting Over A Coat Of Red Lead Primer Etc. All Complete As Per ;Direction Of The Eic 92 Supplying Fitting And Fixing In Position C.I Manhole / Pit Cover With Rim.A ) Square.I ) 600 X 600Mm ( 50Kg.Approx ) . 93 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Superstructure Ground Floor ( 1:6 ) 94 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand Cement Mortar Including Rounding Off Or Chambering Corners As Directed And Raking Out Joints Including Throating Nosing And Drip Course Scafolding / Staging Where Necessary ( Ground Floor ) Excluding Cast At Shipping Over Concrete Surface. Ii ) With 1:4 Cement Mortar ( 10 Mm Thick Cement Plaster ) A ) G.L. To Top Of 1St Bracing 95 B ) 1St Floor I.E. From Top Of 1St Bracing To Top Of 2Nd Bracing 96 C ) 2Nd Floor I.E. From Top Of 2Nd Bracing To Top Of 3Rd Bracing 97 D ) 3Rd Floor I.E. From Top Of 3Rd Bracing To Top Of 4Th Bracing 98 E ) 4Th Floor I.E. From Top Of 4Th Bracing To Top Of 5Th Bracing 99 F ) 5Th Floor I.E. From Top Of 5Th Bracing To Bottom Of Heal Beam 100 G ) 6Th Floor I.E.From Bottom Of Heal Beam To Top Of Ring Beam 101 H ) 7Th Floori.E. From Ring Beam To Rest 102 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand Cement Mortar Including Rounding Off Or Chambering Corners As Directed And Raking Out Joints Including Throating Nosing And Drip Course Scafolding / Staging Where Necessary ( Ground Floor ) Excluding Cast At Shipping Over Concrete Surface. Ii ) With 1:3 Cement Mortar ( 10 Mm Thick Cement Plaster ) A ) 6Th Floor 103 B ) 7Th Floor 104 Supplying & Installation Of Lighting Solid Conductor Rod Of Phosphorous-Bronze Size 2M X 12Mm On The Top Dome Of The Rcc Overhead Reservoir, Laying Lightning Conductor Of 65Mm X 8Mm G.I. ( Hot Deep ) Ms Flatruns From The Roof Upto Gl Along The Shell Wall And Colume Fitted With Necessary Rust Proof Clamps, Lying65mm X 8Mm G.I. ( Hot Deep ) Ms Flat Conductorfrom Gl To Bottom Of The Earthing Main Pipe 80Mm Dia. Tata ( M ) Fitted And Fixedand Connecting With The Main Earthing Gi Pipe Of 80Mm.Dia Tata ( M ) Of 2.50M To Be Used As Earthing Electrode Driven Down To At Least 3.0M Below Gl And Filling Up With Charcoal, Construction Of Masonry Chamber Making As Per Direction Of Eic & Necessary Arrangement For Testing The Same As Per Iee Rule. ( All Work To Be Done As Specification Of Pwd ( Elec. ) Schedule. ) 105 Provision For Embossing The Name And Capacity Of The Reservoir With ( 2:1 ) Raised Sand Cement Plaster With Letter Size 30Cm. X 20Cm. On The Outside Of Shell Wall Of The Reservoir Painted Complete As Per Direction Of Eic. 106 Protective And Decorative Acrylic Exterior Emulsion Paint Of Approved Quality, As Per Manufacturer’S Specification And As Per Direction Of Eic To Be Applied Over Acrylic Primer As Required. The Rate Includes Cost Of Material, Labour, Scaffolding And All Incidental Charges But Excluding The Cost Of Primer. ( Two Coats. ) I ) Super Protective 100% Acrylic Emulsion.A ) G.L. To Top Of 1St Bracing 107 B ) From Top Of 1St Bracing To Top Of 2Nd Bracing 108 C ) From Top Of 2Nd Bracing To Top Of 3Rd Bracing 109 D ) From Top Of 3Rd Bracing To Top Of 4Th Bracing 110 E ) From Top Of 4Th Bracing To Top Of 5Th Bracing 111 F ) From Top Of 5Th Bracing To Top Of Heal Beam 112 G ) From Top Of Heal Beam To Top Of 1 / 3Rd Of Shell Wall 113 H ) From 1 / 3Rd Of Shell Wall To Rest 114 Applying Exterior Grade Acrylic Primer Of Approved Quality And Brand On Plastered Or Concrete Surface Old Or New Surface To Received Decorative Textured ( Matt Finish ) Or Smooth Finish Acrylic Exterior Emulsion Paint Including Scraping And Preparing The Surface Thoroughly, Complete As Per Manufacturer’S Specification And As Per Direction Of The Eic. ( Two Coats ) A ) G.L. To Top Of 1St Bracing 115 B ) From Top Of 1St Bracing To Top Of 2Nd Bracing 116 C ) From Top Of 2Nd Bracing To Top Of 3Rd Bracing 117 D ) From Top Of 3Rd Bracing To Top Of 4Th Bracing 118 E ) From Top Of 4Th Bracing To Top Of 5Th Bracing 119 F ) From Top Of 5Th Bracing To Top Of Heal Beam 120 G ) From Top Of Heal Beam To Top Of 1 / 3Rd Of Shell Wall 121 H ) From 1 / 3Rd Of Shell Wall To Rest 122 Neat Cement Punning About 1.5Mm Thick In Wall, Dado, Window, Ceiling, Floor, Drain Etc. 123 Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothing Surface By Sand Pepering Etc. 124 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc Including Using Of A Approved Putty Etc On The Surface If Necessaryon Steel Or Other Metal Surface ( With Other Than Hi Gloss Of Approved Quality ) . I ) 2 Coats ( With Any Shade Except White ) 125 Painting With Ready Mixed Black Japan Of Approved Make And Brand Including Smoothening Surface.Two Coats. 126 Making Arrangement For Showing The Water Tightness Test Of The Rcc Elevated Reservoir By Filling With Water Upto The Maximum Level Of The Tank To The Full Satisfaction Of Eic ( Arrangements Of Water, Its Carriage And Lifting To The Tank Including Necessary Pipes, Fitting, Pumping Machinery Etc. Are To Be Provided By The Contractor With His Own Cost. ( If Water Is Supplied By The Department Rate Shall Be Reduced As Per Prevailing Departmental Rate ) ) 127 Disinfection And Washing The Tank And Pipe Connections Including Cleaning The Inside Of The Etc. Complete. 128 Hoisting, Erection , Placing Connecting With Pipes And Specials Cidf Pipes, Specials ) Securing With Building Specials Providing Stays, Clamps As Required Including Cost Of Staging Platform For The Work Etc.All Complete In All Respects As Per Drawing And Direction Of Eic.A ) 250Mm.Dia . 129 B ) 150Mm.Dia . 130 C ) 100Mm.Dia . 131 Laying Of Cidf / D.I Pipes With Specials, Valves Etc. In Trenches Including Excavation In All Sorts Of Soil, Moorum, Soft Rock And Refilling The Trenches After Laying & Jointing Of Pipes Etc. All Complete As Per Specification And Direction Of Eic.A ) 250Mm.Dia . 132 B ) 150Mm.Dia . 133 C ) 100Mm.Dia . 134 Fitting, Fixing Duct-Foot Bend Including Construction Of Cement Concrete ( 4:2:1 ) Base With Stone Chips Ofapproved Grade & Quality & Including Excavation Of Earth Etc Complete In All Respect. ( Analysis Rate ) A ) 250Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 135 B ) 150Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 136 C ) 100Mm.Dia ( Base Size 450Mm X 450Mm X 600Mm Deep ) 137 Hoisting, Fitting, Fixing Of Ci Bell Mouth With Puddle Collar In Rcc Work As Per Drawing Specification Complete In All Respect.A ) 250Mm.Dia . 138 B ) 150Mm.Dia . 139 C ) 100Mm.Dia . 140 Construction Of Masonry Drain 300 Mm X 250 Mm Inner Section With 1St Class 250 Mm Th. Brick Work In Cement Mortar ( 1:4 ) Over A Layer Of Single Brick Flat Soling , Sand Filling 100Mm Th. And 100 Mm Th. Weak Cement Concrete ( 6:3:1 ) With Graded Stone Ballast Pakur Variety ( 40Mm Size ) Including Earth Work In Excavation, 15Mm Th. Cement Plaster ( 4:1 ) And Neat Cement Punning All Rounding The Drain Etc. All Complete As Per Approved Design , Drawing And Direction Of The Engineer In-Charge. ( Analysis Rate ) 141 Supply And Delivery Of Different Dia.Cidf Pipe ( Class - B ) I.S: 1538 - 1976 & Specials ( Class - B ) As Per Is: 1538 - 1993 With Latest Amendment Including Loading, Unloading & Stacking Properly For Connection Of Inlet, Outlet, Overflow And Washout Line Of Ohr As Per Departmental Drawing With Specified Dia. Inclusive Of All Incidental Charges If Any All Complete As Per Direction Of The E.I.C. ( Test Certificate From The Manufacturer And Guarantee Certificate Should Be Produced By The Agency ) 142 A ) Supply And Delivery Of Cidf Sluice Valve Pn-10 Of Different Dia Make With Cast Iron Double Flanged Non Rising Spindle Sluice Valve Generally Conforing To I:S 14846-2000 With Latest Amended If Any Having Body Door Dome / Bonnet And Cover Of Cast Iron Gr.- F.G. 200 ( Ref. Is-210 ) Spindle Of Is: 6603 Gr.- 12 / Cr. 13 Non-Magnetic, Nut And Seat Rings Are Gunmetal As Per Is: 1538 Part Iv & Vi Valves Are Suitable For Maximum Working Pressure Of 10Kg / Sq.Cm. ( Seat Test ) And Body Tested To 15Kg / Sq.Cm. ( Test Certificate From The Manufacturer As Well As Inspection Certificate From Third Party Inspection, Agency To Be Arranged By Their Own Cost And To Be Approved By E.I.C. ) N.B. The Above Item Should Be Procured From The Reputed Manufacturer Viz- Kalpana, Jupiter & Upadhaya Or Similar Approved Vender List. [ With Cap ] A ) 250Mm.Dia . 143 B ) 150Mm.Dia . 144 C ) 100Mm.Dia . 145 Construction Of R.C.C. Inlet & Overflow Chamber As Per Drawing Cast With Rcc Wallwithcement Concretenot Leaner Than 1:1.5:3 With Graded 20 Mm Down Pakur Variety Stone Chips And Reforcement Having Wall Thickness 125 Mm And Complete With Plastering 15Mm Th. ( 1:4 ) With Neat Cement Finishing And As Per Direction Of The E.I.C. ( Inner Size = 600 Mm X 600 Mm X 750 Mm ) ( Analysis Rate ) 146 Applyingwate Thinable Non-Toxic Acrylic Polymer Modified Paint Coating Or Equivalent Brand Of Approved Quality 2 ( Two ) Finished Coats Over 2 Coats Of Primer Of Same Brand To The Ceiling Of Roof Dome Including Supplying Supplying Requisite Coating Materials Cleaning Of The Substrant Properly To Make It Free From Dirt, Paint, Oil And Grease Sludge, Blisters, Fungus , Moss, And All Other Undesireble Particles Using Wire Brush , Sand Paper Etc. Including Mending Good All Damages All Complete As Per Direction Of The E.I.C. 147 Supplying Hoisting, Fitting Fixing Approved Type Water Level Indicator With Copper Float, Guide Pulley, Wire Boards Etc. As Per Standard Specification And Direction And Satisfaction Of Eic 148 Site Clearence By Removing All Unserviceablematerials, Debris Etc. All Complete As Per Direction Of E.I.C. 149 Construction Of 3 Nos Pump House And Boundary Wall With Land Development ( Annexure Iv ) Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete.Depth Of Excavation Not Exceeding 1, 500 Mm. 150 Filling In Foundation Or Plinth By Silver Sand In Layers Not Exceeding 150 Mm. As Directed And Consolidating Same By Thorough Saturation With Water Ramming Complete, Including The Cost Of Supply Of Sand. 151 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming Anddressing Bed To Proper Level And Filling Joints With Local Sand. 152 Ordinary Cement Concrete ( 1:2:4 ) With Graded Stone Chips ( 20 Mm Size ) Nominal Size Excluding Shuttering And Reinforcement , If Any In Ground Floor As Per Relevant Is Code. ( A ) Pakur Variety 153 Ordinary Cement Concrete ( Mix 1:1.5:3 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. Pakur Variety 154 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth, In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. ( Payment To Be Made On The Basis Of Measurement Of Finished Quantity Of Work ) ( A ) With Earth Obtained From Excavation Of Foundation. 155 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc. , Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Inter-Section, Complete As Per Drawing And Direction.A ) For Works In Foundation Basement Upto Roof Of Ground Floor / Upto 4 M . I ) Top Steel / Mild Steel [ I. Sail / Tata / Rinl=> Rs.-53241.00 / M; Ii. Other Than Sail / Tata / Rinl=> Rs.-51991.00 / Mt ] 156 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Foundation And Plinth. 157 Brick Work With 1St Class Brick In Cement Morter. ( 1:6 ) In Superstructure Ground Floor ( 1:6 ) 158 125 Mm Thick Brickwork With 1St Class Bricks In Cement Mortar ( 1:4 ) In Ground Floor 159 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4 Mtr Using Approved About Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Concrete Slabs , Beams, Columns, Lintels, Curved Or Straight Including Fitting, Fixing & Striking Out After Completion Of Works ( Upto Roof Of Ground Floor ) A ) 25 Mm To 30 Mm Thick Wooden Shuttering As Per Decision & Direction Of Engineer-In-Charge. 160 25 Mm Thick Damp Proof Course With Cement Concrete With Stone Chips ( 3:1.5:1 ) ) ( With Gradedstone Aggregates 10 Mm Normal Size ) And Paintingthe Top Surface With A Coat Of Bitumen Using 1.7 Kg Per Sq M Including Heating The Bitumen And Cost And Carriage Of All Materials Complete. 161 Plaster ( To Wall, Floor, Ceiling Etc ) With Sand & Cement Mortar Includgrounding Off Or Chamfering Corners As Directed A Ramming Out Joints Or Roughening Of Concretesurface By Chamfering Etc. Including Threading Noising And Drip Course Where Necessary. ( Ground Floor ) I ) With 1:6 Cement Mortar.20 Mm Thick Plaster 162 I ) With 1:6 Cement Mortar.15 Mm Thick Plaster 163 I ) With 1:4 Cement Mortar.10 Mm Thick Plaster 164 Supplying Fitting, Fixing- Openable Steel Windows As Per Is Sizes With Side Hung Shutters And Horizotal Glazing Bars With / Without Fixed Type Ventilators. [ The Extra Rate Admissible For The Openable Portion Only ] ( P-82, I-33 ) 165 Supplying 1.5Mm Thick M.S. Sheet Fitted And Fixed On One Or Both Faces Of M.S. / W.I. Gate Etc. With Point Welding At Not More Than150mm Apart Complete In All Respect As Per Design Including Cost Of All Labour And Materials 166 M.S. Or W.I. Ornamental Grill Of Approved Design, Joints Continuously Welded With M.S. Wi Flats And Bats For Winding, Drilling Etc.Fitted & Fixedwith Necessary Screw And Lugs In Ground Floor. ( I ) Grill Weighing Above 10 Kg. / Sq.Mtr And Up To 16 Kg. / Sq. Mtr.Rs.- 8247.00 / Qt, ( Ii ) Grill Weighing Above 16 Kg. / Sq.Mtr And Abovers.-8053.00 / Qt. 167 Applying Decorative Cement Based Paint Of Approved Quality After Preparing The Surface Including Scraping The Same Thoroughly ( Plastered Or Concrete Surface ) As Per ManufactureS Specification In Ground Floor. A ) Two Coats ( On New Cement Plaster Surface ) 168 White Washing Including Cleaning And Smoothening Surfacethoroughly.A ) 3 Coats. 169 B ) Priming One Coat On Steel Or Other Metal Surface With Synthetic Oil Bound Primer Of Approved Quality Including Smoothening Surfaces By Sand Papering Etc. 170 Painting With Best Quality Synthetic Enamel Paint Of Approved Make And Brand Including Smoothening Surface By Sand Papering Etc Including Using Of A Approved Putty Etc On The Surface If Necessaryb ) On Steel Or Other Metal Surface ( With Other Than Hi Gloss Of Approved Quality ) . I ) 2 Coats ( With Any Shade Except White ) ( Hi Gloss ) 171 Number Plaque Of Buildings ( Plaque Size Upto 225 Mm X 225Mm ) Made Of Cement Plaster ( 2:1 ) On Face Of Wall Or Plinth , With 50 Mm Size Letters P.H.E. And The Number Of The Structure Formed Thereon ( In Sunk Type ) Including Painting The Letters Complete As Per Direction. ( Cement = 1 Kg / No ) 172 Supplying, Fitting And Fixing PeetS Valve Fullway Gunmetal Standard Pattern Best Quality Of Approved Brandbearing I.S.I. Marking With Fittings . ( Tested To 21 Kg / Sq.Cm. ) ( For Water Lines Only ) .- 15 Mm. Dia. 173 Construction Of Septic Tank Of Different Capacities As Per Approved Drawing With 1St Class Brick Work In Cement Mortar ( 1:4 ) Including Two 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Of Approved Make Supplied, Fitted And Fixed In The 100Mm Thick R.C.C ( 1:1.5:3 ) Top Slab With Necessary Fittings, 20Mm Thick Cement Plaster ( 4 : 1 ) With Neat Cement Finish To The Internal Surfaces And 15 Mm Thick Cement Plaster ( 4 : 1 ) To Outside Wall Upto 200 Mm Below G.L Floor Finished With 25 Mm Thick Grey Artificial Stone Over 100 Mm Thick R.C.C ( 1:1.5:3 ) Bottom Slab Including Supplying, Fitting And Fixing All Necessry Specials, Fittings, S.W. Tees, C.I. Foot Rest Etc. Including Excavation Earth In All Sorts Of Soil, Shoring, Bailing Out And Pumping Out Water As Necessary, Ramming, Dressing The Bed And Fefilling The Sides Of The Tanks With Earth, Removing Spoils, Filling Up The Chamber With Clear Water, Removing Foreign Materials From The Chamber And Including Constructing Attached Inspection Pit As Per Approved Drawing And Connecting All Necessary Pipes, Joints Etc. With Internal Plaster Work And Artificial Stone Flooring Is To Be Done With Admixture Of Water Proofing Compound @ 0.5% By Weight Of Cement With All Costs Of Labour And Materials. Note:- ( I ) Finished Level Of Septic Tank Should Be 400 Mm. From Ground Level. ( Ii ) Height Of 50 Mm. Ventilation Pipe &Mosquito Proof Mesh, Should Be Follwed As Per Is:2470, Part I.Payment Will Be Made Separetly On The Basis Of Actual Height Based On Relevant I.S.Code. ( I ) For 10 Usersa ) With Pakur Variety. ( Sail / Tata / Rinl ) 174 Supplying, Fitting & Fixing Orissa Pattern Water Closet In White Glazed Vitreous Chinaware Of Approved Make Supplied , Fitted Fixed In Positioncomplete Excluding P Or S Trap. ( Excluding Cost Of Concrete For Fitting ) I ) 530Mm X 410 Mm 175 Supplying Fitting And Fixing10 Litre Pvc Low-Down Cisternof Conforming To I.S. Specification With Pvc Fitting Complete C.I.Make With Either Side Or Bottom Brackets Including Two Coats Of Painting To Brackets. 176 Supplying Pvc Water Storage Tank Of Approved Quality With Closed Lid ( Black ) -Multilayer. A ) 500 Litre Capacity. 177 Construction Of Circular Soak Well 2.5 Metre Deep In All Types Of Sandy Soils With Dry Brick Work Upto 1.6 Metre From The Bottom Having 150 Mm Intermediate Cement Brick Work ( 1:4 ) Band All Round And Cement Brick Work ( 1:4 ) Upto 0.90 Metre From Top With 20Mm Thick Cement Plastering ( 1:4 ) To Inside Face Upto The Depth Of Cement Brick Work, 15Mm Thick Cement Plaster ( 1:4 ) On Outer Face From Top Of The Well Upto G.L. And 6 Mm Thick Cement Plaster ( 1:4 ) On Top Of The R.C.C. Cover Slab Including Filling Bottom 1.00 Metre Of Inside Of The Well With Brick Metal ( 50 Mm To 63 Mm Size ) Including R.C.C. Cover Slab Of 100 Mm Thick With Cement Conc ( 1:1.5:3 ) With Stone Chips With Necessary Reinforcement And Shuttering Including One 560 Mm Dia. R.C.C. Manhole Cover ( Heavy Type ) Of Approved Make Supplied, Fitted And Fixed In The Cover Slab With Necessary Fittings, Making Nacessary Arrangements For Pipe Connections, Excavation Of Well Including Shoring, Dewatering And Removing The Exess Earth From The Premises As Per Direction Complete In All Respect With All Costs Of Labour And Materials. With 250 Mm Thick Dry Brick Work And 250 Mm Thick Cement Brick Work ( 1:6 ) And 1.00M Inside Dia. ( Sail / Tata / Rinl ) 178 Supplying, Fitting & Fixing Upvc Pipes A-Type And Fittings Conforming To Is:13592-1992 With All Necessary Clamps Nails, Including Making Holes In Walls, Floor Etc. Cutting Trenches In Any Soil Through Masonry Concrete Structures Et. If Necessary And Mending Good Damages Including Joining With Jointing Materials ( Spun Yarn, Valamoid / Bitumen / M-Seal Etc ) Complete. ( A ) 75Mm. Dia. 179 Supplying, Fitting And Fixing Fan Hook For Ceiling With1 Metre Long16mm Dia Rod Complete Including Mending Damages .Payment For Damage And Repair To Be Made Separately. 180 Wash Basin White Vitreous China Of Approved Make ( Without Fittings ) Supplied , Fitted And Fixed In Position On 75Mm X 75Mm X 75Mm Wood Blocks And C.I. Brackets Including Two Coats Of Painting Of C.I. Brackets. ( A ) 450 Mm X 300 Mm Size. 181 Supplying, Fitting And Fixing Approved Brand P.V.C. Connector White Flexible, With Both Ends Coupling With Heavy Brass C.P. Nut, 15 Mm Dia. ( A ) 900 Mm Long. 182 Cutting Holes And Subsequent Mending Good Damages. 183 Supplying , Fitting And Fixing 30 Mm. Thick Both Side Prelaminated Factory Made Solid Panel Pvc Door Shutter Consisting Of Outer Frame Made Out Of Ms Tubes Of 19 Gauge Thickness And Size 19 Mm. X 19 Mm. For Styles, Top And Bottom Rails, Ms Frame Shalll Have Cost Of Steelprimers Of Approved Make And Manufacture, M.S Frame Cover With 5 Mm.Thick Head Moulded Pvc C Channel Of Size 30 Mm. Thick 70Mm. Width Out Of Which 50 Mm. Shall Beflat And 20Mm. Shall Be Tapered In 45 Degree Angle Of Either Side Forming Styles, And 5Mm Thick 95 Mm. Wide Pvc Sheet Out Of Which 75 Mm. Shall Be Flat And 20 Mm. Tapered In 45 Degree On The Inner Side Toform Top & Bottom Rail And 115Mm.Wide Pvc Sheet Out Of Which 75 Mm. Shall Be Flat And 20 Mm. Shall Be Tapered On Both Sides To Form Lock Rail. Top Bottom And Lock Rails Shall Be Provided Either Side Of The Panel With 10Mm. ( 5Mm. X 2 Mm. ) Thick , 20 Mm. Wide Cross Pvc Sheet As Gap Insert For Top Rail And Botttom Rail Sheet To Be Fitted In The M.S Frame Weled / Sealed Tothe Styles &Rails With 7 Mm. ( 5Mm. + 2 Mm. ) Thick X 15 Mm. Wide Pvc Sheet Beading On Inner Side And Joint Together With Solvent Cement Adhesive . An Additional 5 Mm. Thick Pvc Strip Of 20 Mm. Which Is To Be Stuck On The Interior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Com Excluding All Necessary Hardwire As Per Direction Of The E.I.C In Ground Floor. 184 Supplying Fitting Approved Type Ventilator In Position After Cutting Holes In Walls, Setting In Cement Mortar, Mending Damages To Wall And Plaster And Two Coats Of Paint Of Approved Brand Sand Shade .Payment Of Mending Two Damages Of Wall & Plaster And Painting To Be Made Separately.R.C.C. Ventilator Of 20 Mm Thick - Upto 0.10 Sq.M. Area 185 Constructing Inspection Pit Of Inside Measurement 600 Mm X 600 Mm X Upto 600 Mm ( Depth ) With 250 Mm Thick 1St Classbrick Work In Cement Mortar ( 1:4 ) On All Sides , Bottom Of The Pit Consisting Of 100 Mm Thick Cement Concrete ( 1:3:6 ) With Stone Chips Over A Layer Of Jhama Brick Flat Soling, 15 Mm Thick ( 1:4 ) Cement Plaster To Inside Walls And Outside Walls Upto Gl And 20 Mm Thick ( 1:4 ) Plaster To Bottom Of The Pit, Providing Necessary Invert With Cement Concrete ( 1:3:6 ) With Stone Chips As Per Direction, Neat Cement Finishing To Entire Internal Surfaces, Top Of The Pit Covered With 100 Mm Thick Rcc Slab ( 1:1.5:3 ) With Stone Chips And Necessary Reinforcements Upto 1% And Shuttering Including 6 Mm Thick Cement Plaster ( 1:4 ) In All External Surfaces Of The Slab And One 560 Mm Dia Rcc Manhole Cover Of Approved Make Supplied, Fitted And Fixed In The Slab With Necessary Fittings, Necessary Earth Work In Excavation In All Sorts Of Soil, Filling Sides Of The Pit With Earth And Removing Spoils After Work Complete In All Respects With All Costs Of Labour And Materials. -With Pakur Variety. 186 Supplying , Fitting And Fixing Cast Iron P Or S Trap Conforming To I.S. 3989 / 1970 And 1729 / 1964 Including Lead Caulked Joints And Painting Two Coats To The Exposed Surface. ( Painting To Be Paid Seperately ) .- S Trap - 100 Mm. 187 Supplying, Fitting And Fixing Alloy Iron With Brass Spindle Bib Cock / Stop Cock Of Approved Brand And Make, Spray Painted And Tested To 21 Kg Per Sq.Cm. - 15 Mm. Dia. 188 Supplying, Fitting And Fixing Approved Patent Vent Cowl I.C.I. Conforming To I.S.S And Painting Two Coats To The Exposed Surface With Approved Paint Complete. ( Payment Of Painting Will However Be Paid Seperately ) .- 100 Mm Dia. 189 Supplying, Fitting And Fixing Pillar Cock Of Approved Make. A ) I ) Cp Pillar Cock-15 Mm ( Equivalent To Code No-507 & Model - Tropical / Sumthing Special Of Essco Or Similar Brand ) . 190 Earth Work In Filling In Foundation Trenches Or Plinth With Good Earth In Layers Not Exceeding 150 Mm. Including Watering And Ramming Etc. Layer By Layer Complete. A ) With Carried Earth Arranged By The Contractor Within A Radius Of 3 Km. Including Cost Of Carried Earth. 191 Laying For Rising Main & Distribuition System With Fhtc ( Annexure V ) Carrying Ci / Di Pipes With Specials And Valves And Lowering Placing In Position And Laying Carefully Inside The Trenches In Proper Alignment And Gradient Etc.Including Earth Work Inexcavation Of Adequate Width As Per Specification Having Min. Clear Cover From Top Of Pipe Is 1.10Mtr. Below Existing Ground Level In Any Kind Of Soil Including Mixed With Boulder, Road Sub-Grade And Its Flank, But Excluding Moorum And Laterite And Stone Etc.Without Damaging The Exisiting Telephone / Electric Cableetc. ( Incaseof Damaged If Any Type Of Cable Line During Excecution , Necessary Damaged Charges As Applicable By The Respective Authority Will Beborne By The Agency In His Own Cost ) Preparing The Bottom Surface For Continuous Bedding Of Pipe Line And Laying Pipes, Fitting, Fixing Specials And Valves With Bailing Out Water If Any Including Carriage Of Pipes, Specials And Valves From Local Deptt.Store Within 8Km And Back Filling The Trenches With Excavated Earth In Layers To Original Condition As Per Specification And Direction Of Eic. The Surplus Materials After Execution Of Work Are To Be Return To The Deptt. Store.N.B: I ) Any Deviation From Required Clear Cover Of 1.10Mtr., Due To Site Adverse Condition, Prior Permission Is To Be Obtained From The Eic In Exceptional Situation And Payment Will Be Made On Prorate Basis Over The Rate Of Entire Item Ii ) No Payment Will Be Made Without Hydraulic Test Of The Pipe Line Either Part Or Full Iii ) Thepipes, Specials And Valves , Rubber Gasket Will Be Supplied Deptt. Free Of Cost.A ) 150Mm Dia. 192 B ) 200Mm Dia. 193 C ) 250Mm Dia 194 Making Rubber Gasket Joint To Ci / Di Pipes Maintaining Proper Alignment Level Etc. By Mechanical Arrangement With Or Without Using Mobile Cranes Where Necessary And With Help Of All Other Equipments Tools And Tackles Etc. As Required Providing Lubricants Of Approved Quality And Direction Of Eic. ( Rubber Gasket Will Be Supplied Deptt. Free Of Cost ) B ) 150Mm Dia. 195 C ) 200Mm Dia. 196 D ) 250Mm Dia 197 Making Flange Joint To Di / Ci Pipes, Specials And Valves Where Necessary With Supply Of Required Rubber Insertion And Nut Bolts, Washers Etc. Of Approved Quality And Type All Complete As Per Specification And Direction Of Eic ( Nut And Bolts Shall Be Of Tata / Gkw Rate ) .A ) 250Mm Dia 198 B ) 200Mm Dia. 199 C ) 150Mm Dia. 200 E ) 100Mm.Dia . 201 Cutting Di Pipe ( All Class & Type ) To Required Length With Cutting Device Etc. And Grinding The Cutting Portion With File As Per Direction And Satisfaction Of Eic.B ) 150Mm.Dia.To 200Mm.Dia Pipe 202 C ) 250Mm.Dia.To 350 Mm.Dia Pipe 203 Chamfering The Spigot End Of All Type / Class Of Di Pipe For Proper Using Of Push Joint By Means Of Grinder Set At Site For Proper Joint Etc. All Complete As Per Direction Of Eic.B ) 150Mm Dia. 204 C ) 200Mm Dia. 205 D ) 250Mm Dia 206 Filling The Pipe Line With Water, Testing Hydraulically As Per I.S 3114-1965 ( Article-6 ) In Section Of A Length Not Exceeding 500Mtr. For Head Of Pressure As Per Specification Including Supplying Installing And Fixing All Equipments Such As Diesel Pump Set, Blank Flange, Pressure Gauge, Valve, Pressure Pump And All Other Tools And Plants Including Drilling Topping And Plugging Of Necessary Holes To Pipes, Blocking Ends Providing Temporary Thrust Block And Subsequent Blocking Of Holes And Other Jointing Materials And Dismantling And Removal Of The Same Including Disposal Of Water Etc. All Complete As Per Specification And Direction Of Eic. The Rate Is Inclusive Of Cost Of Requisite Water To Be Arranged By The Contractor ( Recovery Rate Of Water @ Rs.10.00 / M3, If Contractor Used Water From Deptt. Source ) .A ) For Ci / Di Pipe.A ) 150Mm Dia. 207 B ) 200Mm Dia. 208 C ) 250Mm Dia 209 B ) For Upvc / Hdpe Pipea ) 50Mm ( Od ) 210 B ) 63Mm ( Od ) 211 C ) 75Mm ( Od ) 212 D ) 90Mm ( Od ) 213 E ) 110Mm ( Od ) 214 F ) 125Mm ( Od ) 215 G ) 140Mm ( Od ) 216 H ) 160Mm ( Od ) 217 I ) 180Mm ( Od ) 218 J ) 200Mm ( Od ) 219 K ) 225Mm ( Od ) 220 Cleaning Thoroughly The Inner Surface Of Pipe Line Including Specials And Valves By Flushing With Water And Subsequently Disinfection Of The Same Pipe Line By Flushing Again With Water Containing Bleaching Powder Resulting In Residual Chlorine Not Less Than 15Mg / Ltrs. After 24Hrs. Of Such Filling Including Laboratory Testing Of Water Samples Obtain From The Disinfested Pipe Line And Disposal Of Water From The Pipe Line After Completion Of The Work. The Rates Including Of Cost Of Requisite Water To Be Arranged By The Contractor ) ( The Rate Of Water @Rs. 10 / M3 May Be Recovered, If The Contractor Used Water From Deptt. Source ) .A ) For Ci / Di Pipe.B ) 150Mm Dia. 221 C ) 200Mm Dia. 222 D ) 250Mm Dia. 223 B ) For Upvc / Hdpe Pipea ) 50Mm ( Od ) 224 B ) 63Mm ( Od ) 225 C ) 75Mm ( Od ) 226 D ) 90Mm ( Od ) 227 E ) 110Mm ( Od ) 228 F ) 125Mm ( Od ) 229 G ) 140Mm ( Od ) 230 H ) 160Mm ( Od ) 231 I ) 180Mm ( Od ) 232 J ) 200Mm ( Od ) 233 K ) 225Mm ( Od ) 234 Submission Of Complete Detailed Drawing Of Distribution System, Rising Main Etc. After Execution Of Work Showing Position Of Different Types Of Valves, Fittings / Specials Sluice Valve Chamber With Location, Node To Node Wise In The Sanctioned Drawing As Completion Drawing Of The Water Supply Scheme As Per Direction And Satisfaction Of Eic. The List Of Dia Wise Fitting / Specials, Different Pipes ;Of Valve Used In The Rising Main Should Be Shown In The Completion Drawing ( Not Separate ) With Verified By Sae & Ae In-Charge Of The Scheme. The Above Drawing Will Be Submitted In 5 Copies. 235 Bituminous Pucca Road ( Approx. 450Mm Depth ) Cutting By Using Gaiti, Chisel, Hammer Etc. And Picking Uip The Withdrawing Excavated Materials And Remove The Same Within Distance Of 30Mtr. At Least All Complete For Fixing / Crossing All Dia Of Pipe Line As Per Direction Of Eic 236 Dismantling All Type Of Plain Cement Concrete Works, Stacking Serviceable Materials Of Site And Removing Rubbish As Directed Within A Lead Of 75Mtr. For Laying All Dia Pipe Line In Ground Floor, Upto 150Mm Thick.A ) Upto 150Mm Thick 237 B ) Above 150Mm Thick 238 Construction Of Different Dia Sluice Valve / Air Valve / Washout Chamber In Different Sizes For Village Road Where Light Traffic Run And For Main Road Where Heavy Traffic Run As Deptt.Approved Drawing With 25Cm Thick Brick Work ( 1:6 ) Over Cement Concrete ( 4:2:1 ) Over A Single B / F Soling Over150mm.Thick Sand Filling In Foundation Including Earth Work In Excavation And Disposal Of Excess Earth From Work Site With Rcc ( 1:1.5:3 ) Cover Slab 100Mm / 150Mm Thick Slab On Top Of Chamber With 1% Reinforcement Inrcc Cover Slab With Necessary Opening For Operation Of Valve All Complete Including Cost Of Labour & Materials As Per Departmental Dwg. [ Reinforcement Type:- Other Manufactuerers Not Specified ] I ) 80 Mm To 150 Mm Dia Pipe 239 Ii ) 200 Mm Dia Pipe 240 Iii ) 250 Mm Dia To 350Mm Dia Pipe 241 Making Holes In Two Sides Of Wall Of Culvert / Drain Or Any Other Structuresin Any Places For Laying Any Dia Pipe Line Within Structures Intwo Sides Of Wall Of Culvert / Drain / Any Structure At Any Places And Mending Good Damages All Complete As Per Direction Of Eic. 242 A ) Construction Of Rcc Street Stand Post ( 700Mm Height ) Of Rcc ( 1:1.5:3 ) Footing Over 75Mm Thick 4:2:1 P.C.C Over A Single B / F Soling With 1% Reinforcement, Connected With Saddlepiece & 15Mm Dia Brass Ferrule With Supplying Fitting, Fixing 15Mm Dia G.I. Nipple, G.I.Socket, G.I. 200Mm X 150Mm Reducing Elbow And 20Mm Dia Gi ( M ) Tata Pipe Of ( Avg. ) 2.6Mtr. Long And One 15Mm Dia Alloy Iron With Brass Spindle Bib Cock With Socket And 20Mm G.I. Elbow 2Nos. With 15Mm Gi ( M ) Tata Pipe Of 0.225Mtr. For Connection Of Stand Post To Distribution Line As Per Deptt. Design And Drawing As Per Direction Of Eic Along With Construction Of Platform Of Size Cc Platform ( 1:2:4 ) Over A Single B / F Soling Below G.L Over 150Mm.Thick Sand Filling, Neat Cement Finish Over Platform And Inner Side Of Band And 15Mm Thick Cement Plaster ( 4:1 ) On Top Of Platform Band And Outside Upto G.L. As Per Deptt. Drawing And As Per Direction Of Eic 243 Supplying Hdpe ( Materials Grade Pe-80 ) Pipes Conforming To Is 4984-1995 With Latest Revision & Amendments If Any With Necessary Hdpe Specials ( Excluding Cost Of Cidf Valves ) Including Labour Charges For Earth Work In Excavation In Any Kind Of Soil Including Mixed Soil With Boulder, Road Sub-Grade And Aits Flank But Excluding Moorum Laterite Or Sand Stone / Hard Rock Cutting With Chisel Required Including Cutting Road Flank / Brick Pavement Etc. Without Damaging The Exisiting Telephone / Electrical Cable Line Etc. ( In Case Of Damage Of Any Type Of Cable Line By The Agency At The Time Of Execution Necessary Damage Charge As Applicable By The Respective Authority Will Have To Be Brone By The Agency At His Own Cost ) Upto The Depth ( Av. ) So As To Maintain 1.10M.Earth Cushion From Top Of The Pipe Upto G.L. Including Loading Unloading Carrying Lowering Laying Fitting Fixing Carefully Pipes, Valves And Specials With The All Types Of Jointing Materials In Trenches Maintaining Proper Levels And Alignment Jointing The Pipes And Specials By Butt Welding / Adopting Suitable Method ( But Weld Jointing With Help Ofhydraulic Tack And Trimming Machines, Hitter Etc. For Reaching At Necessary Melting Point Of Hdpe Pipe So That Joint Can Be Monolithic ) So As To Facilitate The Maintenance Of Pipe Line Locally As Per Conventional Method In Future. ( A ) Pressure Rating : Pn 6Ii ) Laying Of Pipe Line Including Cost Of Pipe & Fittings / Specials Butexcluding Cost Of Valvesa ) 50Mm ( Od ) 244 B ) 63Mm ( Od ) 245 C ) 75Mm ( Od ) 246 D ) 90Mm ( Od ) 247 E ) 110Mm ( Od ) 248 F ) 125Mm ( Od ) 249 G ) 140Mm ( Od ) 250 H ) 160Mm ( Od ) 251 I ) 180Mm ( Od ) 252 J ) 200Mm ( Od ) 253 K ) 225Mm ( Od ) 254 Providing Fhtc From The Existing Cl / Dl / Upvc / Hdpe / Gl / Ac Distribution Pipeline By Installing 10 Mm Nb Gun-Metal Ferrule Conforming To Is 2692:1989 With Latest Amendments On The Said Pipeline With Supply, Fitting & Fixing Of All Other Accessories Like Saddle Piece Of Required Size To Fit The Existing Distribution Pipeline, Specials, Nut & Bolts, Rubber Sheet, Washers Etc And Supply & Laying Of 15Mm Nb Pvc ( Schedule 80 ) / 20Mm Od Hdpe ( Peioo, Pn16 ) Pipe ( Average 15M Length ) With All Necessary Specials 1.0 Metre Below The Ground Connecting The Ferrule Including Cutting Trenches In All Sorts Of Soil And Filling Up Trenches As Per Direction Of The Engineer-In-Charge And Upto A Point Just Inside The Premises Of The Household Or As Directed By Eic. Supply And Installation Of A 15Mm Dia. Alloy Iron Bib Cock ( Tested To 21 Kg / Cm2 ) Above 1.0 Mtr. From Ground, An Alloy Stop Cock Of 15 Mm Dia. With Brass Spindle ( Tested To 21 Kg / Cm2 ) To Be Fitted In A Position As Directed By E.I.C. G.L Pipe Of Tata Make ( Medium Duly ) Of 2 Metre Length With All Necessary Specials To Continue From The End Of The Hdpe / Pvc Pipe And Upto 1.0 M Above Ground Within The Premises Of Household.Note : 1. Pvc Pipe Shall Of Schedule 80 ( Medium Duty ) Conforming To Astmd-1785 And Threaded To Match With Gi Pipe As Per Is: 1239 ( Part-I ) .2. Rate Is Exclusive Of Supply And Delivery Of 10Mm Nb Gun Metal Ferrule.3. Payment Of Supply And Laying Of 15Mm Dia Nb Pvc ( Schedule 80 ) Or 20Mm Od Hdpe ( Pe 100, Pn 16 ) Pipe With All Necessary Specials 1.0M Below The Ground Will Be Made On Actual Measurement Basis. The Rate Of This Item Is Rs. 117 / -Per Metre.A ) Upto 10M Length 255 B ) Above 10M Upto 20M Length 256 Colection Of Household Details As Per Prescribed Formatthrough Mobile App / Hard Copies Including Geo Referance As Diected By E.I.C And Submission Of The Same To The P.H.E Dte.In Soft Copies. 257 Ordinary Cement Concrete ( Mix 1:2:4 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement, If Any, In Ground Floor As Per Relevant Is Codes.A ) Pakur Variety 258 Cost For Boring Any Type Of Soil By Augor Boring ( Horizontal ) With Water Jet System Including Hire Charges Of Machine, Tools & Plants, All Complete With All Labour And Supply Of Water Etc. As Per Specification And Direction Of Eic.I ) 80Mm To 100Mm Dia. 259 Ii ) 125 Mm To 200 Mm Dia 260 Supplying, Fitting And Fixing In Position G.I. Pipes Of Tata Make For Underground Works With All Necessary Accessories, Specials Viz.Socket, Bend, Tee, Union, Cross, Elbow, Nipple, Short Piece Etc.Including Cost Of All Materials, Jointing Materials , Cutting Pipes, Making Threads, Cutting Trenches Upto 1.5 Metre Below Surface In All Sorts Of Soil And Refilling The Same As Directed With Two Coats Of Painting On G.I. Pipes And Specials With Bituminous Paint Complete In All Respect. ( Payment Will Be Made On The Centre Line Measurement Of The Total Pipe Line Including All Specials No Separate Payment Will Be Made For Accessories, Specials.Payment For Painting Will Be Made Seperately ) ( S & P Schedule, Page-2 ) H ) ( Ii ) 80 Mm Dia. Medium Quality. 261 Supplying, Spreading And Consolidating Stone Dust To A Depth Of 100 Mm And Above At Desired Density And C.B.R. As Per Specification With Power Roller To Proper Gradient And Camber Including Watering As Necessary, And Lighting, Guarding, Barricading And Making Adequate Earthen Bundh Where Necessary To Protect The Edges And Curing With Water For 2 To 3 Days, Mending Cracks And Depressions By Rolling Where Necessary Including All Incidental Charges Of Roller, Cost Of Fuel & Lubricants Complete As Per Specification. ( Ref ; Pwd Sor 17 , Page No 242 , Item No 4.06 ) 262 Carriage Of Different Type Of Departmental Pipes From Divisional / Sub-Divisional Store To The Work Site By Truck Including Loading, Unloading, Stacking Etc. Including Cost Of Fuel, Lubricant And Also Cost Of Driver, Helper Etc. And All Other Taxes And Charges As Applicable As Per Direction Of Eicf ) Above 40 Km Upto 50 Km 263 G ) Above 50 Km ( Extra Cost Per Km ) Extra 50 Km ( 4 Nos Truck X 50 Km Each = 200 Km )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
41.
Rural Development #10699720 Price Bid
Supplying Various Type Of Construction And Water Supply Material At Grampanchayat Gose ( Khurd ) , 80 Mm. Metal White- ( Hand Broken Metal ) With Royalty , 40 Mm Metal White- ( Hand Broken Metal ) With Royalty , 40 Mm Metal Black- ( Crusher Broken Metal ) With Royalty , 20 Mm Metal Black- ( Crusher Broken Metal ) With Royalty , 12 Mm Metal Black- ( Crusher Broken Metal ) With Royalty , 6 Mm Metal Black- ( Crusher Broken Metal ) With Royalty , Boulders Rubbles And Masonary Stones , Sand River ( Unscreen ) With Royalty , Sand ( Nallah Bed ) , Soft Murum With Royalty , Hard Murum With Royalty , Soil , Cement 53 Grade Opc , Cement 53 Grade Ppc , Burnt Bricks ( Ii Class ) , Mild Steel Bars Of Various Sizes , Tmt Steel Bars Of Various Sizes , Tmt Steel Bars Of 6Mm , Tmt Steel Bars Of 8Mm , Tmt Steel Bars Of 10Mm , Tmt Steel Bars Of 12Mm , Tmt Steel Bars Of 16Mm , Bitumen Pack Tin 60 / 70 At Mumbai , Murum Carting Only , Weste Material Carting , Mixter Machine Per Day With Desel And Driver , Water Tankerwith Desel And Driver , Centring Rent For Drain Work , Centring Rent For Cement Road , Centring Rent For Building Work , Rcc Pipe 1000 Mm , Rcc Pipe 800 Mm , Rcc Pipe 600 Mm , Rcc Pipe 450 Mm , Rcc Pipe 300 Mm , Compaction Of Earth Work In Embankment Upto Layer Of 30Cm Comp Machinary Charges Only , Compaction Of Soft Murum / Kankad 2.00 To 7.00 Width ( 200Mm Loose ) With Static Roller Including Necessary Artificial Watering Etc Complete , Transporttion Of Soft Murum On Road Side Etc Complete As Per Analysis , Information Board 1 ) Size 1.20 X 0.90 , Information Board 2 ) Size 0.75 X 0.90 , Transportation Of Excavated Soil From Ex-Mat. Tank To Field Up To 3Km , Wooden Door Frame Size 6 * 3.25 , Cement Door Frame Size 6*3.25 , Wooden Door Size 6 * 3.25 , Plywood Door Size 6 * 3.25 , Door Kits Per Door , Precost Sheet , Oil Engine , Meter Stone , Ferlong Stone , Jcb Per Hours , Rollar Per Day With Desel Driver , Griil Work , Murga , Pavour Block ( Gattu ) , Quota Tyles , Vetryfied Tyles , Bt Pod , Wc Pod , Nutritrap , Ms Poor , Ac Sheet , Gi Sheet , Distemper , Birla White , Filtermidiumgravel ( 2Mm To5mm ) , Filtermidiumgravel ( 5Mm To15mm ) , 250Mm Pvc Pipe 6 Kg , 250Mm Pvc Pipe 4 Kg , 200Mm Pvc Pipe 6 Kg , 200Mm Pvc Pipe 4 Kg , 110Mm Pvc Pipe 6 Kg , 110Mm Pvc Pipe 4 Kg , 90Mm Pvc Pipe 6 Kg , 90Mm Pvc Pipe 4 Kg , 75Mm Pvc Pipe 6 Kg , 75Mm Pvc Pipe 4 Kg , 63Mm Pvc Pipe 6 Kg , 63Mm Pvc Pipe 4 Kg , 250Mm Pvc Pipe Elbo , 250Mm Pvc Pipe Bend , 200Mm Pvc Pipe Elbo , 200Mm Pvc Pipe Bend , 110Mm Pvc Pipe Elbo , 110Mm Pvc Pipe Bend , 90Mm Pvc Pipe Elbo , 90Mm Pvc Pipe Bend , 75Mm Pvc Pipe Elbo , 75Mm Pvc Pipe Bend , 63Mm Pvc Pipe Elbo , 63Mm Pvc Pipe Bend , Solution 1 Liter , Solution 1 / 2 Liter , Solution 250Ml , 1 / 2 Gi Pipe , 1 / 2 Gi Pipe ( Bend, Socket, Nipple ) , 250Mm Pvc Socket , 200Mm Pvc Socket , 110Mm Pvc Socket , 90Mm Pvc Socket , 75Mm Pvc Socket , 63Mm Pvc Socket , P V C Connector , Bracket G.I. , 80 Mm Dia. Cidf Sluice Valves , 125 Mm Dia. Cidf Sluice Valves , Dia Poublenrair Valve 200 Mm , Dia Poublenr Air Valve 160 Mm , Dia Poublenr Air Valve 140 Mm , Dia Poublenr Air Valve 110 Mm , Dia Poublenr Air Valve 90 Vmm , Dia Poublenr Air Valve 80 Mm , Dia Poublenr Air Valve 75 Mm , Dia Sluice Valve 300 Mm , Dia Sluice Valve 300 Mm , Dia Sluice Valve 250 Mm , Dia Sluice Valve 200 Mm , Dia Sluice Valve 150 Mm , Dia Sluice Valve 100 Mm , Dia Sluice Valve 80 Mm , Mdpe Pipe 32 Mm , Water Proofing Treatement , Lighting Conductor , Paint Pylimer Isi Mark , Aggregate ( 20Mm ) , Water Level Indicator , Tap , Wall Paint Isi Mark , Oil Paint Isi Mark , Toilet Sheet
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Maharashtra View Result →
42.
Defence #10694384 Price Bid
Tender For Up-Gradation Of Booster Under Mmc-I At Nsg Camp , Manesar; 1 Supplying And Laying Of Following Sizedwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc.Conforming Tois 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 2 120 Mm Dia ( Od-120 Mm & Id-103 Mm Nominal ) 3 200 Mm Dia ( Od-200 Mm & Id-175 Mm Nominal ) 4 The Road Crossings Of Power Cablethrough Trenchless Boring.Trenchless Horizontal Boring Using Manual / Machine Moling Techniqueat 0.75 Metre Below The Ground Level For Following Size Pipes, Including Survey Of Under Ground Utilities, Excavation Of Pits, Moling With The Hole Size Not Exceeding 20% Of The Pipe Dia, Backfilling, Compaction And Restoration Of The Pits To Original Condition Etc. As Required.The Rates For Moling, As Indicated Are Inclusive Of Excavation Of Pits, Backfilling, Compaction Andrestoration Of The Pits To Original Condition.Any Damages Occurred To Other Utilities During The Moling Operation Shall Be Immediately Notified And Rectified By The Contractor Without Any Cost Implication To The Department.The Length Of The Hole ( Excluding The Sizes Of The Pits On Both Ends ) Shall Be Considered For The Measurement Of Moling Length. However, Intermediate Pits Will Consider In The Moling Length.I ) Upto 200 Mm Dia Dwc Hdpe / G.I. / Pvc 5 Providing, Laying And Fixing Following Dia G.I. Pipe ( Medium Class ) In Ground Complete With G.I. Fittings Including Trenching ( 75 Cm Deep ) And Re-Filling Etc. As Required ( Zenith / Tata / Jindal-Hisar / Prakash- Surya Make ) 6 80 Mm Dia Nominal Bore 7 150 Mm Dia Nominal Bore 8 Supplying And Laying Of One Number Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is : 7098 ( Part-1 ) 1988 Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. 9 3.5 X 120 Sq. Mm 10 3.5 X 400 Sq. Mm 11 Supplying And Laying Of One Number Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is : 7098 ( Part-1 ) 1988 Of Following Size In The Existing Rcc / Hume / Metal Pipe As Required. 12 3.5 X 120 Sq. Mm 13 3.5 X 400 Sq. Mm 14 Supplying And Laying Of One Number Aluminium Conductor, Xlpe Insulated, Pvc Sheathed, Armoured Power Cable Of 1.1 Kv Grade , Confirming To Is : 7098 ( Part-1 ) 1988 Of Following Size In The Existing Masonry Open Duct / Along Pole / Loose For Connections Etc As Required. 15 3.5 X 120 Sq. Mm 16 3.5 X 400 Sq. Mm 17 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. [ Make-Comet / Hex / Dowells / Jainson ] 18 3½ X 120 Sq. Mm ( 45Mm ) 19 3½ X 400 Sq. Mm ( 82Mm ) 20 Supply, Installation, Testing And Commissioning Of Outdoor Type Totally Enclosed, Dust And Vermin Proof, Pedestal Mounted Inspection Box / Junction Box Of A Suitable Size But Not Less Than 600 Mm Wide X 900 Mm Height X 450 Mm ( Deep ) Fabricated From 2 Mm Thick Crca Sheet Steel Having Front And Back Openable Doors With Locking Arrangement On Both Sides, Tapered Top ( Roof ) , Including Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Including Pre-Paint Treatment, Phosphating And Powder Coating By Approved Siemens Grey Paint, Consisting Of 500 Amps 4 Strip Aluminium Bus Bars With Heat-Shrinkable Coloured Sleeves And Including Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Etc. As Required, Suitable For Operation On 433 Volts, 50 Hz, 3-Phase, 4-Wire A.C. Supply System, The Entire Panel Shall Have One Common G.I. / Aluminium Bar Of Size 25 Mm X 5 Mm At The Rear With 2 Earth Studs Or Terminals, A Danger Notice Plate Fixed, Etc., Complete As Required. The Feeder Pillar Should Be Complete With A Mounting Frame Made Of 50 Mm X 50 Mm X 6 Mm Angle Iron With 900 Mm Long Legs. The 4 Legs Of The Feeder Pillar Shall Be Erected On A Suitable Size 1:3:6 Cement Concrete ( 1:3:6 Cement; 3 Sand; 6 Graded Stones Of 20 Mm Size ) Pedestal Having 900Mm Of Depth ( 600Mm Below Ground And 300Mm Above Ground ) . 21 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 22 Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 23 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 24 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 25 Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. 26 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required. 27 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 28 Supplying And Making Cable Route Marker With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Of Size 60 Cm X 60 Cm At The Bottom And 50 Cm X 50 Cm At The Top With A Thickness Of 10Cm Including Inscription Duly Engraved As Required. 29 Panel No 01-Booster No 01Fabrication, Supply, Installation, Testing, And Commissioning Of Electrical Control Panel Of Cubical Construction, Floor-Mounted Type, Fabricated Out Of A 2 Mm Thick Crca Sheet With Enclosure Protection Class Ip 42, Suitable For Operation On A 415-Volt, 3-Phase, 50 Hz, 4-Wire A.C. Supply System, Dust- And Vermin-Proof, Powder-Coated In An Approved Siemens Gray Shade After 7 Tank Pre-Treatment Processes. The Panel Shall Be Compartmentalized Type With Hinged Lockable Doors, Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Cable Alleys Of Suitable Size On Both Sides For Cabling Routing, Openable Type Rear Cover And Complete With 4 Strips Of Aluminium Bus Bars Of 400 Amps Capacity With Heat-Shrinkable Coloured Sleeves And Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Control Terminals, And Suitable Sized Terminal Blocks For Incoming And Outgoing Cables, Including Providing And Fixing Interconnection From Busbars To Switch Gears And Up To Terminal Blocks With Suitable Sized Insulated Aluminium Conductor / Solid Aluminium Strip And Control Wiring With Suitable Sized Insulated Copper Conductor Cable, Including Suitable Size M.V. Danger Board Fixed On Panel. The Entire Panel Shall Have One Common Copper Bar Of Size 25 Mm X 5 Mm At The Rear With Two Earth Studs / Terminals. 30 The Panel Shall Be Supplied With A Bottom Base Ms Channel, Not Less Than 100 Mm X 50 Mm X 5 Mm Thick. Suitable Size Of M.V. Danger Boards Shall Be Fixed On Panel. The Panel Base Should Have Four 300 Mm Long Legs ( Made Of Angle Irons 50 X 50 X 6 Mm Or Other Suitable Means ) To Raise The Panel From The Floor, And A Removable 2 Mm Thick Powder-Coated Crca Sheet Cover Must Be Provided On Four Sides Of The Pedestal. The Base Frame Of The Panel Should Be Grouted Into The Floor With Four 12Mm Dia X 200Mm Long Bolts And Nuts.The Panel Shall Have Provision To Accommodate The Following Switch Gears As Mentioned Below In Item No 18 And With The Required Front Area ( Approximate Front Area 2000 Mm X 1500 Mm ) And Depth Minimum 450 Mm. ( Drawings Will Be Approved Before Fabrication Of The Panel ) . 31 Providing And Fixing The Following Switch Gears, Metres, And Accessories On The Existing Cubicle Panel Board, Including Drilling Holes In The Panel, Making Connections, Testing And Commissioning, Etc. As Required. ( Panel No 01-Booster No 01 ) 32 400 Amps, Four Poles, Mccb, 50 Ka, With Microprocessor Base Overload And Short Circuit Protection Release, Ics = 100% Of Icu, And Withspreader Terminals. 33 Direct Rotary Handle ( Rhom ) For 400 A Mccb 34 3Ph Led Ammeter Cl -1 With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 35 3Ph Led Voltmeter Cl 1 ( 0-500V ) With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 36 Mcb Sp 6A, C-Curve 10Ka 37 Cts 400 / 5 A Amps, 15 Va With Class 1.0 Accuracy 38 Led Indicator Lamp, Red. 240 V Ac. 39 Led Indicator Lamp, Yellow. 240 V Ac. 40 Led Indicator, Lamp, Blue, 240V Ac. 41 Star Delta Starter ( As Per The Following Details For 50 Hp / 37 Kw, Three-Phase, 415 Volt Motor Pump Set ) 01 Nos 42 125 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn1-160M L&T Or Similar Specification In Siemens / Abb / Schnider ) 43 Direct Rotary Handle ( Rhom ) For 125 A Mccb 44 3 Pole, 415 V, Power Contactor Ac3 Dutyrating95 A. 45 Overload Relay. Mn12 ( 28-46.5A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 46 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 47 Cts 150 / 5 Amps, 5Va With Class 1.0 Accuracy 48 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 49 Star Delta Timer. 50 Led Indicator Lamp, Red. 240 V Ac. 51 Led Indicator Lamp, Yellow. 240 V Ac. 52 Led Indicator, Lamp, Blue, 240V Ac. 53 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 54 Push Button For Start ( Green ) 55 Contact Block No For Push Button 56 Push Button Forstop ( Red ) 57 Contact Block Nc For Push Button 58 Mcb Dp, 10Ka, 10 Amp For Control Circuit. 59 On, Off, Trip Indicating Lamps. 60 Auto-Manual Selector Switch. 61 Star Delta Starter ( As Per The Following Details For 30 Hp / 22 Kw, Three-Phase, 415 Volt Motor Pump Set ) 01 Nos 62 100 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 63 Direct Rotary Handle ( Rhom ) For 100 A Mccb 64 3 Pole, 415 V, Power Contactor Ac3 Dutyrating80 A. 65 Overload Relay. Mn5 ( 20-33A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 66 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 67 Cts 100 / 5 Amps, 5Va With Class 1.0 Accuracy 68 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 69 Star Delta Timer. 70 Led Indicator Lamp, Red. 240 V Ac. 71 Led Indicator Lamp, Yellow. 240 V Ac. 72 Led Indicator, Lamp, Blue, 240V Ac. 73 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 74 Push Button For Start ( Green ) 75 Contact Block No For Push Button 76 Push Button Forstop ( Red ) 77 Contact Block Nc For Push Button 78 Mcb Dp, 10Ka, 10 A For Control Circuit. 79 On, Off, Trip Indicating Lamps. 80 Auto-Manual Selector Switch. 81 40 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 82 Direct Rotary Handle ( Rhom ) For 40 A Mccb 83 125 Amps , Tp, Mccb, 36 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protectiondz1-160D 84 Direct Rotary Handle ( Rhom ) For 125 A Mccb 85 Panel No 02 ( Booster No 01 ) Fabrication, Supply, Installation, Testing, And Commissioning Of Electrical Control Panel Of Cubical Construction, Floor-Mounted Type, Fabricated Out Of A 2 Mm Thick Crca Sheet With Enclosure Protection Class Ip 42, Suitable For Operation On A 415-Volt, 3-Phase, 50 Hz, 4-Wire A.C. Supply System, Dust- And Vermin-Proof, Powder-Coated In An Approved Siemens Gray Shade After 7 Tank Pre-Treatment Processes. The Panel Shall Be Compartmentalized Type With Hinged Lockable Doors, Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Cable Alleys Of Suitable Size On Both Sides For Cabling Routing, Openable Type Rear Cover And Complete With 4 Strips Of Aluminium Bus Bars Of 400 Amps Capacity With Heat-Shrinkable Coloured Sleeves And Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Control Terminals, And Suitable Sized Terminal Blocks For Incoming And Outgoing Cables, Including Providing And Fixing Interconnection From Busbars To Switch Gears And Up To Terminal Blocks With Suitable Sized Insulated Aluminium Conductor / Solid Aluminium Strip And Control Wiring With Suitable Sized Insulated Copper Conductor Cable, Including Suitable Size M.V. Danger Board Fixed On Panel. The Entire Panel Shall Have One Common Copper Bar Of Size 25 Mm X 5 Mm At The Rear With Two Earth Studs / Terminals. 86 The Panel Shall Be Supplied With A Bottom Base Ms Channel, Not Less Than 100 Mm X 50 Mm X 5 Mm Thick. Suitable Size Of M.V. Danger Boards Shall Be Fixed On Panel. The Panel Base Should Have Four 300 Mm Long Legs ( Made Of Angle Irons 50 X 50 X 6 Mm Or Other Suitable Means ) To Raise The Panel From The Floor, And A Removable 2 Mm Thick Powder-Coated Crca Sheet Cover Must Be Provided On Four Sides Of The Pedestal. The Base Frame Of The Panel Should Be Grouted Into The Floor With Four 12Mm Dia X 200Mm Long Bolts And Nuts.The Panel Shall Have Provision To Accommodate The Following Switch Gears As Mentioned Below In Item No 20 And With The Required Front Area ( Approximate Front Area 2000 Mm X 1200 Mm ) And Depth Minimum 450 Mm. ( Drawings Will Be Approved Before Fabrication Of The Panel ) . 87 Providing And Fixing The Following Switch Gears, Metres, And Accessories On The Existing Cubicle Panel Board, Including Drilling Holes In The Panel, Making Connections, Testing And Commissioning, Etc. As Required. ( Panel No 02-Booster No 01 ) 88 400 Amps, Four Poles, Mccb, 50 Ka, With Microprocessor Base Overload And Short Circuit Protection Release, Ics = 100% Of Icu, And Withspreader Terminals. 89 Direct Rotary Handle ( Rhom ) For 400 A Mccb 90 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 91 3Ph Led Voltmeter Cl 1 ( 0-500V ) With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 92 Cts 400 / 5 A Amps, 15 Va With Class 1.0 Accuracy 93 Led Indicator Lamp, Red. 240 V Ac. 94 Led Indicator Lamp, Yellow. 240 V Ac. 95 Led Indicator, Lamp, Blue, 240V Ac. 96 Mcb Sp 6A C-Curve 10Ka 97 Star Delta Starter ( As Per The Following Details For 30 Hp / 22 Kw, Three-Phase, 415 Volt Motor Pump Set ) 02 Nos 98 100 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 99 Direct Rotary Handle ( Rhom ) For 100 A Mccb 100 3 Pole, 415 V, Power Contactor Ac3 Dutyrating80 A. 101 Overload Relay. Mn5 ( 20-33A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 102 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 103 Cts 100 / 5 Amps, 5 Va With Class 1.0 Accuracy 104 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 105 Star Delta Timer. 106 Led Indicator Lamp, Red. 240 V Ac. 107 Led Indicator Lamp, Yellow. 240 V Ac. 108 Led Indicator, Lamp, Blue, 240V Ac. 109 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 110 Push Button For Start ( Green ) 111 Contact Block No For Push Button 112 Push Button Forstop ( Red ) 113 Contact Block Nc For Push Button 114 Mcb Dp, 10Ka, 10Afor Control Circuit. 115 On, Off, Trip Indicating Lamps. 116 Auto-Manual Selector Switch. 117 Mcb Dp, 10Ka, 40Amp For Control Circuit. 118 40 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 119 Direct Rotary Handle ( Rhom ) For 40 A Mccb 120 125 Amps , Tp, Mccb, 36 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protectiondz1-160D 121 Direct Rotary Handle ( Rhom ) For 125 A Mccb 122 ( Panel No 03 -Booster No Typeiv ) Fabrication, Supply, Installation, Testing, And Commissioning Of Electrical Control Panel Of Cubical Construction, Floor-Mounted Type, Fabricated Out Of A 2 Mm Thick Crca Sheet With Enclosure Protection Class Ip 42, Suitable For Operation On A 415-Volt, 3-Phase, 50 Hz, 4-Wire A.C. Supply System, Dust- And Vermin-Proof, Powder-Coated In An Approved Siemens Gray Shade After 7 Tank Pre-Treatment Processes. The Panel Shall Be Compartmentalized Type With Hinged Lockable Doors, Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Cable Alleys Of Suitable Size On Both Sides For Cabling Routing, Openable Type Rear Cover And Complete With 4 Strips Of Aluminium Bus Bars Of 400 Amps Capacity With Heat-Shrinkable Coloured Sleeves And Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Control Terminals, And Suitable Sized Terminal Blocks For Incoming And Outgoing Cables, Including Providing And Fixing Interconnection From Busbars To Switch Gears And Up To Terminal Blocks With Suitable Sized Insulated Aluminium Conductor / Solid Aluminium Strip And Control Wiring With Suitable Sized Insulated Copper Conductor Cable, Including Suitable Size M.V. Danger Board Fixed On Panel. The Entire Panel Shall Have One Common Copper Bar Of Size 25 Mm X 5 Mm At The Rear With Two Earth Studs / Terminals. 123 The Panel Shall Be Supplied With A Bottom Base Ms Channel, Not Less Than 100 Mm X 50 Mm X 5 Mm Thick. Suitable Size Of M.V. Danger Boards Shall Be Fixed On Panel. The Panel Base Should Have Four 300 Mm Long Legs ( Made Of Angle Irons 50 X 50 X 6 Mm Or Other Suitable Means ) To Raise The Panel From The Floor, And A Removable 2 Mm Thick Powder-Coated Crca Sheet Cover Must Be Provided On Four Sides Of The Pedestal. The Base Frame Of The Panel Should Be Grouted Into The Floor With Four 12Mm Dia X 200Mm Long Bolts And Nuts.The Panel Shall Have Provision To Accommodate The Following Switch Gears As Mentioned Below In Item No 22 And With The Required Front Area ( Approximate Front Area 2000 Mm X 1200 Mm ) And Depth Minimum 450 Mm. ( Drawings Will Be Approved Before Fabrication Of The Panel ) . 124 Providing And Fixing The Following Switch Gears, Metres, And Accessories On The Existing Cubicle Panel Board, Including Drilling Holes In The Panel, Making Connections, Testing And Commissioning, Etc. As Required. ( Panel No 03 -Booster No Typeiv ) 125 400 Amps, Four Poles, Mccb, 50 Ka, With Microprocessor Base Overload And Short Circuit Protection Release, Ics = 100% Of Icu, And Withspreader Terminals. 126 Direct Rotary Handle ( Rhom ) For 400 A Mccb 127 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 128 3Ph Led Voltmeter Cl 1 ( 0-500V ) With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. ( Single Function Meters. 129 Cts 400 / 5 A Amps, 15Va With Class 1.0 Accuracy 130 Led Indicator Lamp, Red. 240 V Ac. 131 Led Indicator Lamp, Yellow. 240 V Ac. 132 Led Indicator, Lamp, Blue, 240V Ac. 133 Mcb Sp 6A C-Curve 10Ka 134 Star Delta Starters ( As Per The Following Details For 25 Hp / 18.5 Kw, Three-Phase, 415 Volt Motor Pump Set ) 02 Nos 135 80 Amps , Tp, Mccb, 50 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protection With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 136 Direct Rotary Handle ( Rhom ) For 80 A Mccb 137 3 Pole, 415 V, Power Contactor Ac3 Dutyrating80 A. 138 Overload Relay. Mn5 ( 14-23A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 139 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 140 Cts 100 / 5 Amps, 5 Va With Class 1.0 Accuracy 141 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 142 Star Delta Timer. 143 Led Indicator Lamp, Red. 240 V Ac. 144 Led Indicator Lamp, Yellow. 240 V Ac. 145 Led Indicator, Lamp, Blue, 240V Ac. 146 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 147 Push Button For Start ( Green ) 148 Contact Block No For Push Button 149 Push Button Forstop ( Red ) 150 Contact Block Nc For Push Button 151 Mcb Dp, 10Ka, 10 A For Control Circuit. 152 On, Off, Trip Indicating Lamps. 153 Auto-Manual Selector Switch. 154 Mcb Dp, 10Ka, 40 Amp For Control Circuit. 155 40 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 156 Direct Rotary Handle ( Rhom ) For 40 A Mccb 157 125 Amps , Tp, Mccb, 36 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protectiondz1-160D 158 Direct Rotary Handle ( Rhom ) For 125 A Mccb 159 Panel No 04 ( Type 2 Qtrs ) Fabrication, Supply, Installation, Testing, And Commissioning Of Electrical Control Panel Of Cubical Construction, Floor-Mounted Type, Fabricated Out Of A 2 Mm Thick Crca Sheet With Enclosure Protection Class Ip 42, Suitable For Operation On A 415-Volt, 3-Phase, 50 Hz, 4-Wire A.C. Supply System, Dust- And Vermin-Proof, Powder-Coated In An Approved Siemens Gray Shade After 7 Tank Pre-Treatment Processes. The Panel Shall Be Compartmentalized Type With Hinged Lockable Doors, Detachable Cable Gland Plates Made Of 3 Mm Thick Crca Sheet, Cable Alleys Of Suitable Size On Both Sides For Cabling Routing, Openable Type Rear Cover And Complete With 4 Strips Of Aluminium Bus Bars Of 400 Amps Capacity With Heat-Shrinkable Coloured Sleeves And Frp / Dmc / Smc Bus Bar Supports At Required Intervals, Control Terminals, And Suitable Sized Terminal Blocks For Incoming And Outgoing Cables, Including Providing And Fixing Interconnection From Busbars To Switch Gears And Up To Terminal Blocks With Suitable Sized Insulated Aluminium Conductor / Solid Aluminium Strip And Control Wiring With Suitable Sized Insulated Copper Conductor Cable, Including Suitable Size M.V. Danger Board Fixed On Panel. The Entire Panel Shall Have One Common Copper Bar Of Size 25 Mm X 5 Mm At The Rear With Two Earth Studs / Terminals. 160 The Panel Shall Be Supplied With A Bottom Base Ms Channel, Not Less Than 100 Mm X 50 Mm X 5 Mm Thick. Suitable Size Of M.V. Danger Boards Shall Be Fixed On Panel. The Panel Base Should Have Four 300 Mm Long Legs ( Made Of Angle Irons 50 X 50 X 6 Mm Or Other Suitable Means ) To Raise The Panel From The Floor, And A Removable 2 Mm Thick Powder-Coated Crca Sheet Cover Must Be Provided On Four Sides Of The Pedestal. The Base Frame Of The Panel Should Be Grouted Into The Floor With Four 12Mm Dia X 200Mm Long Bolts And Nuts.The Panel Shall Have Provision To Accommodate The Following Switch Gears As Mentioned Below In Item No 24 And With The Required Front Area ( Approximate Front Area 2000 Mm X 1200 Mm ) And Depth Minimum 450 Mm. ( Drawings Will Be Approved Before Fabrication Of The Panel ) . 161 Providing And Fixing The Following Switch Gears, Metres, And Accessories On The Existing Cubicle Panel Board, Including Drilling Holes In The Panel, Making Connections, Testing And Commissioning, Etc. As Required ( Panel No 04 -Type 2 Qtrs ) 162 250 Amps, Four Poles, Mccb, 50 Ka, With Microprocessor Base Overload And Short Circuit Protection Release, Ics = 100% Of Icu, And Withspreader Terminals. 163 Direct Rotary Handle ( Rhom ) For 250 A Mccb 164 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. 165 3Ph Led Voltmeter Cl 1 ( 0-500V ) With Inbuilt Selector Switch For 3 Phases. Flush Mounting 96 X 96 Mm. ( Single Function Meters. 166 Cts 250 / 5 A Amps, 10Va With Class 1.0 Accuracy 167 Led Indicator Lamp, Red. 240 V Ac. 168 Led Indicator Lamp, Yellow. 240 V Ac. 169 Led Indicator, Lamp, Blue, 240V Ac. 170 Mcb Sp 6A C-Curve 10Ka 171 Star Delta Starter ( As Per The Following Details For 15 Hp / 11 Kw, Three-Phase, 415 Volt Motor Pump Set ) 01 Nos 172 50 Amps , Tp, Mccb, 50 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protection With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 173 Direct Rotary Handle ( Rhom ) For 50 A Mccb 174 3 Pole, 415 V, Power Contactor Ac3 Dutyrating50 A. 175 Overload Relay. Mn5 ( 9-15A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 176 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 177 Cts 50 / 5 Amps, 5Va 178 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 179 Star Delta Timer. 180 Led Indicator Lamp, Red. 240 V Ac. 181 Led Indicator Lamp, Yellow. 240 V Ac. 182 Led Indicator, Lamp, Blue, 240V Ac. 183 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 184 Push Button For Start ( Green ) 185 Contact Block No For Push Button 186 Push Button Forstop ( Red ) 187 Contact Block Nc For Push Button 188 Mcb Dp, 10Ka, 10A For Control Circuit. 189 On, Off, Trip Indicating Lamps. 190 Auto-Manual Selector Switch. 191 Star Delta Starter ( As Per The Following Details For 25 Hp / 18.5Kw, Three-Phase, 415 Volt Motor Pump Set ) 01 Nos 192 80 Amps , Tp, Mccb, 50 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protection With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 193 Direct Rotary Handle ( Rhom ) For 80 A Mccb 194 3 Pole, 415 V, Power Contactor Ac3 Dutyrating80 A. 195 Overload Relay. Mn5 ( 14-23A ) Of L&Tor Similar Specification In Siemens / Abb / Schneider ) 196 Add-On Aux. Contact Block ( 1 No + 1 Nc ) For Star Delta Starter. 197 Cts 100 / 5 Amps, 5 Va With Class 1.0 Accuracy 198 Single Phasing Preventer With U / V &O / V , 3 Ph, 415 V Ac. 199 Star Delta Timer. 200 Led Indicator Lamp, Red. 240 V Ac. 201 Led Indicator Lamp, Yellow. 240 V Ac. 202 Led Indicator, Lamp, Blue, 240V Ac. 203 3Ph Led Ammeter Cl 1 With Inbuilt Selector Switch For 3 Phases. 204 Push Button For Start ( Green ) 205 Contact Block No For Push Button 206 Push Button Forstop ( Red ) 207 Contact Block Nc For Push Button 208 Mcb Dp, 10Ka, 10 A For Control Circuit. 209 On, Off, Trip Indicating Lamps. 210 Auto-Manual Selector Switch. 211 Mcb Dp, 10Ka, 40 Amp For Control Circuit. 212 40 Amps , Tp, Mccb, 50 Ka Breaking Capacity With Spreaders Terminals. ( Dn0-100M L&T Or Similar Specification In Siemens / Abb / Schnider ) 213 Direct Rotary Handle ( Rhom ) For 40 A Mccb 214 125 Amps , Tp, Mccb, 36 Ka Breaking Capacity , Ics = 100% Icu Withadjustable Overloadand Adjustable Short-Circuit Protectiondz1-160D 215 Direct Rotary Handle ( Rhom ) For 125 A Mccb 216 Providing And Fixing 3 Ph Multifunction Meter For The Measurement Of Parameters Voltage, Current, Power Factor, Frequency, Kw And Kwhflush Mounting In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections And Testing, Etc. As Required. 217 Providing And Fixingadd-On Aux. Contact Block ( 2 No + 2 Nc ) ) Forpower Contactorin Existing Cubicle Panel Board Including Making Connections, Etc. As Required. 218 Providing And Fixing 400 Amps , 4 Pole, 415 V, Category Ac-23A. On Load Change Over Switch, In Open Execution In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 219 Credit For Existing Panel.Disconnection Of Existing Motor Control Panels Installed At The Following Places From Their Foundation And Disconnection Of Incoming And Outgoing Connections And Credit For The Panels.I ) Booster No 01 -2 Nos Panel.Ii ) Booster No Type Iv -1 No Panelii ) Booster Near Type 2 -1 No Panel 220 Add 1.0633 Multiplying Factor For Gst On Dsr
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
43.
Rural Development #10693968 Price Bid
Supplying Of Electrical Materials And Repairs Maintenance Services At. Grampanchayat Sawardari, Tal. Khed, Dist. Pune- 1 Supplying and erecting modulartype switch6A / 10A ISImark approved make duly erected on provided plate and box with wiring connections complete.(8-1-2) 2 Supplying and erecting Street light bracket for erection ofSingle fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm diaduly welded as per specification no. 3 Providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles) (16-3-2) 4 Supplying and erecting Street light bracket made from 25mm. dia ‘B’class G.I. Pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification 5 Supplying,TPMCB 40A to 63A in provided distribution board 6 Providing pair of duly tested rubber hand gloves as per IS:4770 suitable for working upto 22kV supply. 7 Supplying and erecting Insulated D.P. switch surface type/flush type 32A 240Vwith indicator lamp & fuse 8 SupplyingH.C. pattern porcelain fuse bridge swith base & HC type fuse links240V 32A 9 Supplying and erecting Programmable Digital AlmanacTimer Microcontroller based with real time clock to operate on derived switching “ON” & switching “OFF” street light as per daily sunset and sunrise respectively 10 1.25 mm CRCA sheet metal enclosures with 20A. 11 Supplying PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV (1-3-29) 12 Supplying and erectingLED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65 and above Housing of pressure die cast alluminium alloy and heat sink 2-9-5 13 Supplying and erectingLED street light fitting suitable for 26w To 36w LED Street Light, including lamp, with PF > 0.95 class IP 65 and above Housing of pressure die cast alluminium alloy and heat sink 2-9-5 14 Supplying & LayingPVC armoured cable 4core 10 sq mm7-1-15 15 Supplying & erecting fuse bridges with base H.C. type fuse links 240V 63A 5-10-9 16 Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) 5-3-3 17 Supplying, erecting & marking DPMCB 6 A to 32 A Bseries (for lighting) 5-3-7 18 Supplying, erecting & marking TPMCB 6 A to 32Amp in provided distribution board 5-3-14 19 Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board 5-3-17 20 Supplying & erecting crimping type Aluminium lugs for cable upto 16 sq mm complete 7-10-1 21 Supplying & erecting crimping type Coper lugs for cable upto 1.5 To 6sq mm complete… 22 Supplying and erecting two pole power contactor 250V 32A for time switch complete erected on wooden block/provided box, with necessary materials. 4-4-3 23 Supplying & erecting mains with2x1.5 sq.mm F.R copperPVC insulated wire laid in provided conduit/trunking/inside pole 1-3-3 24 Supplying and erecting mains with ISI mark WP2 x 6 sq. mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire No. 8 SWG 1-4-3 25 Supplying and erecting mains with ISI mark WP2 x 2.5 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 26 Supplying and erecting mains with ISI mark WP2 x 10.00 sq mm. 1100 V. Grade aluminium PVC insulated PVC sheathed wires on G.I. bearer wire 27 25 Amp, 32 Amp Three Phase L/T Contactor 28 2.5 Sq. mm Multistand Copper Wire 29 Insulation Tape 30 Water Proof Tape 31 Cable Joint Kit upto 16 Sq. MM Cable 32 Street Light Pole Box FRP 33 Street Light Pole Clamp Round Type 34 Supplying and laying (including excavation) 50 mm outside dia. double wall corrugated pipes (DWC) 35 Servicing And Primary Maintenance For Street Light Pole.. 36 Light Pole Painting 37 26W LED Light To 100W LED Light Repairing 38 Old Pole Shifting , Rework and Foundation Work per Pole 39 Supply &Fixing of Shakle Hardware with Nut Bolt 40 Supply and Installation of Mini Feeder Pillar with Stand 41 RCC Road Cheasling Charges with Tractor Breaker (1 Hours) 42 Tree Triming for Overhead Line 43 Supplying and erecting Solar panel comprising highefficiency mono-crystalline / multi crystalline Photovoltaic Cell 40 Wp, 12V, with necessary clamps and module frame on existing structure as per specification no 44 Supplying and erecting approved makebattery with capacity of 12 V 40 AH with duty cycle 10-12 hrs suitable to charge on PV cell with necessary wiring connections erected in powder coated protection box with stand and nut bolts as per specification no.ESD-SOL/BAT 4-3-17 45 Solar Battery Bracket 46 Solar Battery Box High Quality… 47 Servicing And Primary Maintenance of Solar Light Pole 1 visit in month included and Also Call Basis. Checking All Wire Connections, NuT Bolt Tighting, Lugs Connection, Timer Working Condition and Panel Cleaning 48 Distilled Water (1 Ltr.) 49 Panel Frame For Old Pole 50 Solar Light Fixture with Light 9W / 12W Aluminim Dia Casting with Charge Controller & Lithinium Battery With Auto On / Off System.. 51 Providing Rental basis Hydraulic Bucket Vehicle of Highth 14 Mtr. And Weight Capacity 250 Kg with Driver, Oprator and disel etc. for per day basis.. 52 Supplying & Erecting rolled steel Joist girder pole (125 X 70 mm ) 13.3 kg/mwith provided base plate in provided foundation as per specification No. OH-PL/RS 53 SupplyinganderectingG.I.fly stay set for pole including straining screw, G.l. stay wire, 7/10 SWG (for to 15mtr. long) with pole clamp, made of 50 x 6 mm MS flat,completeerectedon provided RSJ pole. (Add. Rs. 25/- per m for extra length beyond 15 m) 54 Supplyinganderectingpoleclamp madefrom50 x 10 mmMS flat for pole or pipe, post completeerected with 15 mm bolts and nuts, complete duly painted with one coat of red oxide and two coats of aluminium paint. 55 Supplyinganderecting ‘D’ type pole clamps, fabricatedfrom50 x 6 mm MS flatwith 15 mmdia. bolts and nutfixed tosteeltubularpoleduly paintedwithonecoatofred oxide and two coats of aluminium paint. 56 Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EAEP 57 Supplying anderecting all aluminium stranded conductors 7/2.21mm complete. (Gnat) (73.77kg/km) as per specification no. OH-CON/AAC 58 Supplying & erectingMS pole bracket for guarding/LT OH Line, fabricated from angle iron 50x50x6 mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. OH -PL/BKT 59 Supplying & erectingMS pole bracket for guarding/LT OH Line, fabricated from angle iron 50x50x6 mm and 550 mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. OH -PL/BKT 60 Dismantlingtheexistingpole above 6 m heightwithbrackets,clamps,insulators, stayfromthecement concretefoundationand making the siteclearbyrefilling the pitswith excavated materials and bringing it to the ground level. 61 Dismantling the existing overhead line including G.I. wires of all sizes withoutdamaging & makingthecoilsinsuitablesizes. 62 Supplying and erecting metal work in CRCA sheet with fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 63 Supplying & erecting MS pole bracket for guarding/LT OH Line fabricated from ISM channel 75x40x6mm and 550 mm longfor necessary nos. of provided insulators and erecting on pole with 50x6mm clampcomplete as per specification no. OH-PL/BKT 64 Supplying and erecting aluminium bobbin with G.I. (shackle) strip, nuts complete. 65 Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner. 66 Supplying and erecting mains with ISI markWP 2 x 6 sq. mm. 1100 V. grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
44.
Rural Development #10693628 Price Bid
Supplying Providing Electrical Material At Gp Gahunje For ( 1 Year ) Supplying Providing Electrical Material At Gp Gahunje For ( 1 Year ) Tal-Maval, Dist-Pune , Supplying And Erecting Modulartype Switch6a / 10A Isimark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. ( 8-1-2 ) , Supplying And Erecting Street Light Bracket For Erection Ofsingle Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. , Providing Cement Concrete Foundation Including Excavationfor The Poles 60 Cm X 60 Cm X 1.5 M Deep In 1:3:6 Cement Concrete ( 20 X 25 Mm Stone Metal ) And 45 Cm X 45 Cm X 45 Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Approved Manner. ( For 8.5 To 9 M Poles ) ( 16-3-2 ) , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness ( 4.5 + 1.75 + 1.75M ) Length Respectively And Total 8 M Long With Pole Cap, Base Plate In Provided Foundation. ( Weight 101 Kg. ) As Per Specification No. Oh-Pl / Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm. Dia With 4.5 X 4.5 X 3.65 Mm Thickness ( 5 + 2 + 2M ) Length Respectively And Total 9 M Long With Pole Cap, Base Plate In Provided Foundation ( Weight 147 Kg ) As Per Specification No. Oh-Pl / Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia. With 4.5 X4.5 X3.65 Mm Thickness ( 5.60 + 2.7 + 2.7 M ) Length Total 11 M Long With Pole Cap, Base Plate In Provided Foundation ( Weight 175 Kg. ) As Per Specification No. . Oh-Pl / Stp , Supplying And Erecting Street Light Bracket Made From 25Mm. Dia ‘B’Class G.I. Pipe, 0.6M. In Lengthalong With Polecap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification , Supplying, Tpmcb 40A To 63A In Provided Distribution Board , Providing Pair Of Duly Tested Rubber Hand Gloves As Per Is:4770 Suitable For Working Upto 22Kv Supply. , Supplying And Erecting Insulated D.P. Switch Surface Type / Flush Type 32A 240Vwith Indicator Lamp & Fuse , Supplyingh.C. Pattern Porcelain Fuse Bridge Swith Base & Hc Type Fuse Links240v 32A , Supplying And Erecting Programmable Digital Almanactimer Microcontroller Based With Real Time Clock To Operate On Derived Switching “On” & Switching “Off” Street Light As Per Daily Sunset And Sunrise Respectively , 1.25 Mm Crca Sheet Metal Enclosures With 20A. , Supplying Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm ( 30 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv ( 1-3-29 ) , Supplying And Erecting Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink 2-9-5 , Supplying And Erectingled Street Light Fitting Suitable For 26W To 36W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink 2-9-5 , Supplying And Erectingled Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With Pf > 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink 2-9-5 , Supplying And Erecting Led Flood Light Fitting Of 120W, Including Lamp, With Pf > 0.95, Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification No Fg Odf / Fls-2 , Supplying & Layingpvc Armoured Cable 4Core 6Sq Mm , Supplying & Layingpvc Armoured Cable 4Core 10 Sq Mm7-1-15 , Supplying & Layingpvc Armoured Cable 2Core 10 Sq Mm , Supplying & Layingpvc Armoured Cable 4Core 16 Sq Mm , Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) 5-3-3 , Supplying, Erecting & Marking Dpmcb 6 A To 32 A Bseries ( For Lighting ) 5-3-7 , Supplying, Erecting & Marking Tpmcb 6 A To 32Amp In Provided Distribution Board 5-3-14 , Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board 5-3-17 , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Upto 16 Sq Mm Complete 7-10-1 , Supplying & Erecting Crimping Type Coper Lugs For Cable Upto 1.5 To 6Sq Mm Complete… , Supplying And Erecting Two Pole Power Contactor 250V 32A For Time Switch Complete Erected On Wooden Block / Provided Box, With Necessary Materials. 4-4-3 , Supplying & Erecting Mains With2x1.5 Sq.Mm F.R Copperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole 1-3-3 , Supplying And Erecting Mains With Isi Mark Wp2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg 1-4-3 , Supplying And Erecting Mains With Isi Mark Wp2 X 2.5 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , Supplying And Erecting Mains With Isi Mark Wp2 X 10.00 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , 25 Amp, 32 Amp Three Phase L / T Contactor , 2.5 Sq. Mm Multistand Copper Wire , Insulation Tape , Water Proof Tape , Cable Joint Kit Upto 16 Sq. Mm Cable , Street Light Pole Box Frp , Cement Street Light Pole Clamp , M.S. Street Light Pole Clamp , Servicing And Primary Maintenance Of Street Light Pole 1 Visit Per Month Pole Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection. Old Light Changing & Service Wire Conection Labour Works Etc. , Supplying And Laying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. , Servicing And Primary Maintenance For Street Light Pole. , Light Poles Painting In Silver Colour , 26W Led Light To 100W Led Light Repairing , Old Pole Shifting, Rework And Foundation Work Per Pole Etc. , Supply &Fixing Of Shakle Hardware With Nut Bolt , Supply And Installation Of Mini Feeder Pillar With Stand , Rcc Road Cheasling Charges With Tractor Breaker ( 1 Hours ) , Tree Triming For Overhead Line , Supplying And Erecting Solar Panel Comprising Highefficiency Mono-Crystalline / Multi Crystalline Photovoltaic Cell 40 Wp, 12V, With Necessary Clamps And Module Frame On Existing Structure As Per Specification No , Supplying And Erecting Approved Makebattery With Capacity Of 12 V 40 Ah With Duty Cycle 10-12 Hrs Suitable To Charge On Pv Cell With Necessary Wiring Connections Erected In Powder Coated Protection Box With Stand And Nut Bolts As Per Specification No.Esd-Sol / Bat 4-3-17 , Servicing And Primary Maintenance Of Solar Light Pole 1 Visit In Month Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection, Timer Working Condition And Panel Cleaning , Solar Light Fixture With Light 9W / 12W Aluminim Dia Casting With Charge Controller & Lithinium Battery With Auto On / Off System.. , Providing Rental Basis Hydraulic Bucket Vehicle Of Highth 13 Mtr. And Weight Capacity 200 Kg With Driver, Oprator And Disel Etc. For Per Day Basis.. , 7-1-33 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 70 Sq. Mm. Aluminium Conductor With Continuous 8.35 Sq. Mm. ( 10 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al , 7-1-31 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 35 Sq. Mm , 7-1-34Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 95 Sq. Mm , 7-1-35 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 120 Sq. Mm , 5-3-4 Supplying, Erecting & Marking Spmcb 40A To 63A C- Series ( For Motor / Power ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , 5-3-5 Supplying, Erecting & Marking Spmcb 40A To 63A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Swswr / Mcb , 5-3-8 Supplying, Erecting & Marking Dpmcb 40A To 63A, C- Series ( For Motor / Power ) In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , 5-3-9 Supplying, Erecting & Marking Dpmcb 40A To 63A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Swswr / Mcb , 5-3-15 Supplying, Erecting & Marking Tpmcb 40A To 63A In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , 5-3-17 Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , 5-3-27 Supplying, Fixing And Commissioning Mcb Type Change Over Switch 2 Pole, 25 A With 3 Positions ( I-O-Ii ) With Centre Off Position As Per Specification No. Sw-Swr / Mcbcos , 5-3-28 Supplying, Fixing And Commissioning Mcb Type Change Over Switch 2 Pole, 40 A With 3 Positions ( I-O-Ii ) With Centre Off Position As Per Specification No. Sw-Swr / Mcbcos , 5-3-29Supplying, Fixing And Commissioning Mcb Type Change Over Switch 2 Pole, 63 A With 3 Positions ( I-O-Ii ) With Centre Off Position As Per Specification No. Sw-Swr / Mcbcos , 5-3-32 Supplying, Fixing And Commissioning Mcb Type Change Over Switch 4 Pole, 63A With 3 Positions ( I-O-Ii ) With Centre Off Position As Per Specification No. Sw-Swr / Mcbcos , 7-9-4 Supplying & Erecting Crimping Type Copper Lugs For Cable 50 Sq. Mm. Complete As Per Specification No. Cb-Cl / Cu , 7-9-5 Supplying & Erecting Crimping Type Copper Lugs For Cable 70 Sq. Mm. Complete As Per Specification No. Cb-Cl / Cu , 7-9-7 Supplying & Erecting Crimping Type Copper Lugs For Cable 120 Sq.Mm. Complete As Per Specification No. Cb-Cl / Cu , 4-4-5 Supplying And Erecting Four Pole Power Contactor 430 V, 40 A For Time Switch Complete Erected On Provided Wooden Block / Box, With Necessary Materials. , Supplying And Erecting Icdp Switch 10A To 63A , Cable Joint Kit For Armoured Cable 20 Upto 120Sq. Mm Cable , Gi Tar , Ahuja Speaker System ( Pa ) 110W To 250W With Mic Speakers And Coils. Etc , Kit Kat Type Fuse 16A 32A 63A 120A , Taparia Tester , Spaner Set , Control Panel Hrc Fuse , Supplying And Erecting Transformer Fidder Piller , 5-2-19 Supplying & Erecting Street Light Control Panel In Powder Coated Crca 14 / 16 Swg Sheet, Outdoor Type, Three Phase, 415V Consisted Of Suitable Rating Contactor, 24 Hrs Digital / Astronomical Time Switch With Minimum 5 Years Battery Backup, Tpn Mcb 63 A Auto / Manual Selector Switch, On / Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection Of Street Lights Upto The Max Load Of 12 Kw On Provided Iron Frame / Cc Foundation Complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
45.
Rural Development #10677749 Price Bid
Supply Various Of Construction . Material And Other Material Supp . Various Of Const . Material And Other Material At Gp Dokesarandi Ps Lakhandur , 80 mm . metal white- ( hand broken metal ) with royalty , 40 mm metal white- ( hand broken metal ) with royalty , 40 mm metal black- ( crusher broken metal ) with royalty , 20 mm metal black- ( crusher broken metal ) with royalty , 12 mm metal black- ( crusher broken metal ) with royalty , 6 mm metal black- ( crusher broken metal ) with royalty , boulders rubbles and masonary stones , sand river ( unscreen ) with royalty , sand ( nallah bed ) , soft murum with royalty , hard murum with royalty , soil , cement 53 grade opc , cement 53 grade ppc , burnt bricks ( ii class ) , mild steel bars of various sizes , tmt steel bars of various sizes , tmt steel bars of 6mm , tmt steel bars of 8mm , tmt steel bars of 10mm , tmt steel bars of 12mm , tmt steel bars of 16mm , bitumen pack tin 60/70 at mumbai , murum carting only , weste material carting , mixter machine per day with desel and driver , water tanker with desel and driver , centring rent for drain work , centring rent for cement road , centring rent for building work , rcc pipe 1000 mm , rcc pipe 800 mm , rcc pipe 600 mm , rcc pipe 450 mm , rcc pipe 300 mm , compaction of earth work in embankment upto layer of 30cm comp machinary charges only , compaction of soft murum/ kankad 2 . 00 to 7 . 00 width ( 200mm loose ) with static roller including necessary artificial watering etc complete , transporttion of soft murum on road side etc complete as per analysis , information board 1 ) size 1 . 20 x 0 . 90 , information board 2 ) size 0 . 75 x 0 . 90 , transportation of excavated soil from ex-mat . tank to field up to 3km , wooden door frame size 6 * 3 . 25 , cement door frame size 6*3 . 25 , wooden door size 6 * 3 . 25 , plywood door size 6 * 3 . 25 , door kits per door , precost sheet , oil engine , meter stone , ferlong stone , jcb per hours , rollar per day with desel driver , griil work , murga , pavour block ( gattu ) , quota tyles , vetryfied tyles , bt pod , wc pod , nutri trap , ms poor , ac sheet , gi sheet , distemper , birla white , hand wash basin , pvc pipe 150mm , pvc pipe 110mm , pvc pipe 90mm , pvc pipe 75mm , pvc pipe 63mm , whiting , centring tar , reduser 160*140 , reduser 140*110 , reduser 110*90 , reduser 90*70 , reduser 75*63 , reduser 75*40 , elbow round , nipples , sddle peace , ferud , g . i pipe b class 50 mm , g i flanged , panel board ( fabrication work ) , sub mersible motor pump 10 hp , sub mersible motor pump 06 hp , sub mersible motor pump 5 hp , sub mersible motor pump 3 hp , sub mersible cable 3 core 2 . 50 sq . mm , walve 80 mm , sluice walve 80mm , air walve 50 mm , elcb , voltmeter , ammeter , selector swithch , dol starter , condensor 2 kvar , earthing plate , cange over switch 16 amp , solar pump , power socket , power switch , rcc chair 3 seated , solar fan , solar ceilling fan , fevicol hitex , glass 12mm , metal screw19-6 , metal screw 25-8 , metal screw 32-8 , valve 65 mm , sluice walve 65mm , oil paint isi mark , primer , distemper , bleaching powder isi mark , hand wash basin , ceramic tile , peving block color coated ( standerd ) , iron jali , alumium windows , pvc connector , inwell boar drilling , relay , tape patti , coil , grip , g . i pipe 2 inch , g . i pipe 3 inch , flance , nat bolt , plastic socket , foot tooth , ci joint , joint rassi , packing , kit patti , best , bolt hh , solution , pastic water tank , 1/18 wire fflexible tamba ( 1 bundle ) , 1/18 wire alumiun ( 1 bundle ) , 3/20 wire alumium ( 1 bundle ) , 1/18 wire tamba ( 1 bundle ) , 3/20 wire tamba ( 1 bundle ) , sevice wire 4 mm , bulb holder , insulator 40 amp . , insulator 60 amp . , capecitor 2 . 5 mfd , 32 amp main switch ( ashok ) , 63amp main switch ( ashok ) , 100 amp main switch ( ashok ) , kitcatt fuse 32 amp . , kitcatt fuse 63 amp . , kitcatt fuse 16 amp . , led street light 25 watt ( syska ) , led street light 30 watt ( syska ) , led street light 40 watt ( syska ) , led street light 50watt ( syska ) , led light 15 watt ( syska ) , led light 18 watt ( syska ) , led light 20 watt ( syska ) , led light 26 watt ( syska ) , led light 35 watt ( syska ) , led light 40 watt ( syska ) , mdpe pipe 32 mm , dia pouble nr air valve 200 mm , dia pouble nr air valve 160 mm , dia pouble nr air valve 140 mm , dia pouble nr air valve 110 mm , dia pouble nr air valve 90 vmm , dia pouble nr air valve 80 mm , dia pouble nr air valve 75 mm , dia sluice valve 300 mm , dia sluice valve 300 mm , dia sluice valve 250 mm , dia sluice valve 200 mm , dia sluice valve 150 mm , dia sluice valve 100 mm , dia sluice valve 80 mm , water suply valve sacket 200 mm , water suply valve sacket 160 mm , water suply valve sacket 140 mm , water suply valve sacket 110 mm , water suply valve sacket 90 mm , water suply valve sacket 80mm , water suply valve sacket 75 mm , water suply t verious size , water suply bend verious size , water suply elbowverious size , ms chasing , 90 mm dia pvc 6 kg/cm2 , water proofing treatement , lighting conductor , ladder , aggregate ( 20mm ) , water level indicator , telfish ( verious size ) , d joint , nrv 250 mm , rubber sheet
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
46.
Rural Development #10677744 Price Bid
supply of Various Of Construction Material And Other Material Supp . Various Of Const . Material And Other Material At Gp Karandala Ps Lakhandur , 80 mm . metal white- ( hand broken metal ) with royalty , 40 mm metal white- ( hand broken metal ) with royalty , 40 mm metal black- ( crusher broken metal ) with royalty , 20 mm metal black- ( crusher broken metal ) with royalty , 12 mm metal black- ( crusher broken metal ) with royalty , 6 mm metal black- ( crusher broken metal ) with royalty , boulders rubbles and masonary stones , sand river ( unscreen ) with royalty , sand ( nallah bed ) , soft murum with royalty , hard murum with royalty , soil , cement 53 grade opc , cement 53 grade ppc , burnt bricks ( ii class ) , mild steel bars of various sizes , tmt steel bars of various sizes , tmt steel bars of 6mm , tmt steel bars of 8mm , tmt steel bars of 10mm , tmt steel bars of 12mm , tmt steel bars of 16mm , bitumen pack tin 60 / 70 at mumbai , murum carting only , weste material carting , mixter machine per day with desel and driver , water tanker with desel and driver , centring rent for drain work , centring rent for cement road , centring rent for building work , rcc pipe 1000 mm , rcc pipe 800 mm , rcc pipe 600 mm , rcc pipe 450 mm , rcc pipe 300 mm , compaction of earth work in embankment upto layer of 30cm comp machinary charges only , compaction of soft murum / kankad 2 . 00 to 7 . 00 width ( 200mm loose ) with static roller including necessary artificial watering etc complete , transporttion of soft murum on road side etc complete as per analysis , information board 1 ) size 1 . 20 x 0 . 90 , information board 2 ) size 0 . 75 x 0 . 90 , transportation of excavated soil from ex-mat . tank to field up to 3km , wooden door frame size 6 * 3 . 25 , cement door frame size 6*3 . 25 , wooden door size 6 * 3 . 25 , plywood door size 6 * 3 . 25 , door kits per door , precost sheet , oil engine , meter stone , ferlong stone , jcb per hours , rollar per day with desel driver , griil work , murga , pavour block ( gattu ) , quota tyles , vetryfied tyles , bt pod , wc pod , nutri trap , ms poor , ac sheet , gi sheet , distemper , birla white , hand wash basin , pvc pipe 150mm , pvc pipe 110mm , pvc pipe 90mm , pvc pipe 75mm , pvc pipe 63mm , whiting , centring tar , reduser 160*140 , reduser 140*110 , reduser 110*90 , reduser 90*70 , reduser 75*63 , reduser 75*40 , elbow round , nipples , sddle peace , ferud , g . i pipe b class 50 mm , g i flanged , panel board ( fabrication work ) , sub mersible motor pump 10 hp , sub mersible motor pump 06 hp , sub mersible motor pump 5 hp , sub mersible motor pump 3 hp , sub mersible cable 3 core 2 . 50 sq . mm , walve 80 mm , sluice walve 80mm , air walve 50 mm , elcb , voltmeter , ammeter , selector swithch , dol starter , condensor 2 kvar , earthing plate , cange over switch 16 amp , solar pump , power socket , power switch , rcc chair 3 seated , solar fan , solar ceilling fan , fevicol hitex , glass 12mm , metal screw19-6 , metal screw 25-8 , metal screw 32-8 , valve 65 mm , sluice walve 65mm , oil paint isi mark , primer , distemper , bleaching powder isi mark , hand wash basin , ceramic tile , peving block color coated ( standerd ) , iron jali , alumium windows , pvc connector , inwell boar drilling , relay , tape patti , coil , grip , g . i pipe 2 inch , g . i pipe 3 inch , flance , nat bolt , plastic socket , foot tooth , ci joint , joint rassi , packing , kit patti , best , bolt hh , solution , pastic water tank , 1 / 18 wire fflexible tamba ( 1 bundle ) , 1 / 18 wire alumiun ( 1 bundle ) , 3 / 20 wire alumium ( 1 bundle ) , 1 / 18 wire tamba ( 1 bundle ) , 3 / 20 wire tamba ( 1 bundle ) , sevice wire 4 mm , bulb holder , insulator 40 amp . , insulator 60 amp . , capecitor 2 . 5 mfd , 32 amp main switch ( ashok ) , 63amp main switch ( ashok ) , 100 amp main switch ( ashok ) , kitcatt fuse 32 amp . , kitcatt fuse 63 amp . , kitcatt fuse 16 amp . , led street light 25 watt ( syska ) , led street light 30 watt ( syska ) , led street light 40 watt ( syska ) , led street light 50watt ( syska ) , led light 15 watt ( syska ) , led light 18 watt ( syska ) , led light 20 watt ( syska ) , led light 26 watt ( syska ) , led light 35 watt ( syska ) , led light 40 watt ( syska ) , mdpe pipe 32 mm , dia pouble nr air valve 200 mm , dia pouble nr air valve 160 mm , dia pouble nr air valve 140 mm , dia pouble nr air valve 110 mm , dia pouble nr air valve 90 vmm , dia pouble nr air valve 80 mm , dia pouble nr air valve 75 mm , dia sluice valve 300 mm , dia sluice valve 300 mm , dia sluice valve 250 mm , dia sluice valve 200 mm , dia sluice valve 150 mm , dia sluice valve 100 mm , dia sluice valve 80 mm , water suply valve sacket 200 mm , water suply valve sacket 160 mm , water suply valve sacket 140 mm , water suply valve sacket 110 mm , water suply valve sacket 90 mm , water suply valve sacket 80mm , water suply valve sacket 75 mm , water suply t verious size , water suply bend verious size , water suply elbowverious size , ms chasing , 90 mm dia pvc 6 kg / cm2 , water proofing treatement , lighting conductor , ladder , aggregate ( 20mm ) , water level indicator , telfish ( verious size ) , d joint , nrv 250 mm , rubber sheet
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
47.
Rural Development #10674562 Price Bid
Supply And Installation Of DIESEL GENERATOR Set 25 Kv For Mc Office In Palwal ( Retender ) Supply And Installation Of Dg Set 25 Kv For Mc Office In Palwal ( Retender ) , Civil Work , Supply, Installation, Testing And Commissioning Of Load Bank With Digital Meter Module Cost Of Digital Amp. I Volt Meter With Selector Switch Wiring ( But Exluding Cost Of Incoming And Outgoing Mccbs ) Etc.Suitable For Operation Of 240 / 415 Volts Ac. Supply With Both Side Cable Allay, Inter Connection And Fixing The Same In Existing Ms Pedestal / Wall Complete With All Labour And Material Required For The Same Up To The Entire Satisfaction Of Engineer-In-Charge Of Work.23.24.4.2 Load Bank 8 Way 250 Am , New Hsr 23.27.1Supply And Erection Of Godrej Almirah Typem.S. Pedestal Made Of 50 Mm X 50 Mm X 6 Mm Angle Iron Frame With 3.00 Mm Thick M.S. Sheet Covering Including Shutters With Suitable Hinges And Locking Arrangement With Godrej Type Handle Including Round Bars. The Top Covering Should Have Downward Overhang Of 75 Mm On All Sides Of Pedestal, Having Two Sets Of Water Proof Ventilation Holes Of Suitable Size On The Sides , At Top And Bottom , Each Set Containing Four Nos. Holes To Discharge The Heat Produced By The Current. The Shutters Fixed With Rubber Gasket Of Superior Quality And Of Suitable Size To Make It Water Proof . The Pedestal Duly Painted Both Inside And Outside With Two Coats Of Approved Paint And Primary Coat And Its Legs Are Embeded Upto The Entire Depth In 1 :2:4 Cement Concrete Block , Projected 75 Mm All Around The Pedestal And And 200 Mm Above The Ground Level Including The Cost Of All Labour And Material Required To Complete The Job In All Respect Upto The Entire Satisfaction Of The Engineer In-Charge Of The Work:Supply And Erection Of Godrej Almirah Typem.S. Pedestal Made Of 50 Mm X 50 Mm X 6 Mm Angle Iron Frame With 3.00 Mm Thick M.S. Sheet Covering Including Shutters With Suitable Hinges And Locking Arrangement With Godrej Type Handle Including Round Bars. The Top Covering Should Have Downward Overhang Of 75 Mm On All Sides Of Pedestal , Having Two Sets Of Water Proof Ventilation Holes Of Suitable Size On The Sides , At Top And Bottom , Each Set Containing Four Nos. Holes To Discharge The Heat Produced By The Current. The Shutters Fixed With Rubber Gasket Of Superior Quality And Of Suitable Size To Make It Water Proof . The Pedestal Duly Painted Both Inside And Outside With Two Coats Of Approved Paint And Primary Coat And Its Legs Are Embeded Upto The Entire Depth In 1 :2:4 Cement Concrete Block , Projected 75 Mm All Around The Pedestal And And 200 Mm Above The Ground Level Including The Cost Of All Labour And Material Required To Complete The Job In All Respect Upto The Entire Satisfaction Of The Engineer In-Charge Of The Work: M.S. Pedestal Of Size 600 Mm Wide , 750 Mm High , 300 Mm Deep And Each 5436 Bottom Totally Open , Duly Embeded In 1 :2:4 Cement Concrete Block Of Size 750 Mm X 450 Mm X 200 Mm Above Ground Level , Having A Base Of Size 900 Mm X 600 Mm X 250 Mm Below Ground Level. , New Hsr 24.2.2.3Laying Of Underground Cable 0. 75 Metre Below Ground Level Covered With Sand And Bricks Including Excavation And Refilling Of Trenches.:-16 Sq Mm To 35 Sqmm 2 To 4 Core 50 Sq Mm To 150 Sqmm 2 To 4 Cor , New Hsr 24.7.1 Providing Rcc Foundation Of M20 Grade ( 1 Cement:1.5 Stone Aggregate: 3 Coarse Sand ) I / C Excavation, Steel Reinforcement ( Fe 500 ) @ 50 Kg / Cum Of Concrete Contents, Concrete Cover 50Mm, Over A Bed Of 75Mm Thick Pcc 1:5:10, Of Required Dimensions As Per Oem Recommendations To Provide Levelled Surface For Placement Of The Dg Set Complete In All Respects And As Per Directions Of Engineer-In-Charge ( Size Of Foundation Assumed = 5.0X1 .Bx1 .Om ) 30 To 40 Kva Dg Set , New Hsr 20.89 -3 --Designing, Supply & Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 + ( - ) 1% Volts Ac Alternator Coupled Directly Through A Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over / Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover / Standard Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover / Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specifications And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. +A ) Diesel Engine B ) Alternator C ) Battery 24 V. D ) Base Plate. E ) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Metres. F ) Tools, Standard Panel G ) Metering Set 415 Vac-1 Set ( Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, Cts ) H ) Metering Set 60 / 5A / 11 Ov ( Amp. Meter, Volt Meter ) I ) Overload Protection For Dc-1 No. J ) Battery Charger 24V Dc K ) Copper Bus Bar Of Suitable Size I ) Kwh Meter 96 Sqmm Size M ) Starting Fuse Button And Key Switch9on / Off ) N ) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, De Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 25 Kv , Sitc Four Pole On Load Manual Change Over Switch In Ss Enclosure Of Hsr23.22.8.2 100 Amp 415 Volt
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 1
48.
Power #10656217 Price Bid
Augmentation / Renovation And Modernization Of 33 / 11 Kv Receiving Station Sunjwan From 2X1.5 Mva To 2X3.15 Mva Along With, Erection Of New 33 Kv Line ( 2Nd Source ) From 33 / 11 Kv, 3X10 Mva, Receiving Station Channi Himmat To Receiving Station Sunjwan, Stabilization / Strengthening Of Existing 33 Kv Line ( 1St Source ) And Other Allied Works Relating To Receving Station Mes Sunjwan, Jammu On Turnkey Basis- 1 Substation Main Equipment 2 33 Kv Transformer Bay & Single Bus 33 Kv Line Bay 3 33 Kv Vcb ( 36 Kv, 1250A, 26.2 Ka, Outdoor Type ) 4 33 Kv Isolator Without Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 5 33 Kv Current Transformer ( 33 Kv, 1F, Multi Ratio Multi Core, Outdoor ) ( 1 No. Per F ) 6 33 Kv Voltage Transformer ( 33 Kv / 110 V, 1F, Multi-Core, Outdoor ) , ( 1No. Per F ) 7 33 Kv Lightening Arrestors ( 30 Kv, 10Ka, Station Class, Zno, Polymer ) Gap Less 8 33 Kv Polymer Post Insulator36kv, 170Kv Impulse, Creepage Distance 1224M 9 33Kv C&R Panel Along Witho / C, E / F Relays, Diffrential Relay, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps With Rs-485 Port, Dlms Compliant With Rs-485 Port ( For Power Transformers ) 10 33Kv C&R Panel Along Witho / C, E / F Relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps With Rs-485 Port, Dlms Compliant With Rs-485 Port 11 Steel Structures 12 Galvanised Steel Structures 13 Galvanised Nuts & Bolts 14 Conductor And Hardware 15 200 Mm² Acsr Panther Conductor 16 T Clamps 17 Tension Fitting Suitable For 200 Mm Sq Conductor. 18 33 Kv Polymer Composite Disc Insulators 36 Kv, Min Falling Load 70 Kn, Lightening Impulse 170 Kv Positive And 180 Kv Negative, Creepage Distance 900 Mm. 19 Earth Wire 7 / 3.15 Mm Sq. 20 Gi Flat For Earthing 50X6mm & 25X3 Mm 21 3.15 Mva , 33 / 11 Kv Power Transformer 22 33 / 11Kv, 3.15 Mva Onan, Copper Wound, Out-Door Type, Conventional Power Transformer, Oil Filled With Oltc And All Accessories Including Ht And Lt Terminal Connections 23 Power Control Cables And Accessories 24 12 Core, 2.5 Mm Sq. 25 6 Core, 2.5 Mm Sq. 26 4 Core, 2.5 Mm Sq. 27 2 Core, 2.5 Mm Sq. 28 Lugs, Ferrules Etc. 29 Laying Of 33 Kv Line ( Approximately 1.9 Km ) 30 13 Mtr. Long St Poles ( St-410Sp69 ) 31 G.I Channel ( 100X50x6 ) Mm Sq, G.I Angle ( 65X65x6 ) Mm, G.I Angle ( 50X50x6 ) Mm Sq. Sq., G.I Flat ( 50X6 ) Mm Sq. 32 200 Mm2acsr Panther Conductor 33 P.G. Clamp For 200 Mm2 Acsr Panther Conductor 34 33 Kv Pin Insulators Polymer Type ( 10Kn ) 35 33 Kv Polymer Composite Disc Insulators 36 Kv, Min Falling Load 70 Kn, Lightening Impulse 170 Kv Positive And 180 Kv Negative, Creepage Distance 900 Mm. 36 Tension Fitting Suitable For 200 Mm Sq Conductor. 37 Galvanised Nuts And Bolts With Washers 38 33 Kv Danger Plates With Clamps 39 Anti-Climbing Device With Clamps 40 Earthing Complete ( Gi Pipe 40 Mm Or Gi Rod 20 Mm, 2.5 Mtr Long With Gi Strip ) 41 33 Kv Isolatorwithout Earthing Blade 42 Red Oxide Paint 43 Aluminum Paint. 44 Cement Bottoming ( 1:2:4 Mix As Per Rec Standards, 6 Cum / Pole ) 45 Aluminium Jointing Sleeevs 46 Insertion Of 11 Mtr St Poles In Existing 33Kv Line 47 11 Mtr. Long St Poles ( St-410Sp56 ) 48 G.I Channel ( 100X50x6 ) Mm Sq, G.I Angle ( 65X65x6 ) Mm, G.I Angle ( 50X50x6 ) Mm Sq. Sq., G.I Flat ( 50X6 ) Mm Sq. 49 200 Mm2acsr Panther Conductor 50 P.G. Clamp For 200 Mm2 Acsr Panther Conductor 51 33 Kv Pin Insulators Polymer Type ( 10Kn ) 52 33 Kv Polymer Composite Disc Insulators 36 Kv, Min Falling Load 70 Kn, Lightening Impulse 170 Kv Positive And 180 Kv Negative, Creepage Distance 900 Mm. 53 Tension Fitting Suitable For 200 Mm Sq Conductor. 54 Galvanised Nuts And Bolts With Washers 55 33 Kv Danger Plates With Clamps 56 Anti-Climbing Device With Clamps 57 Earthing Complete ( Gi Pipe 40 Mm Or Gi Rod 20 Mm, 2.5 Mtr Long With Gi Strip ) 58 Red Oxide Paint 59 Aluminum Paint. 60 Cement Bottoming ( 1:2:4 Mix As Per Rec Standards, 6 Cum / Pole ) 61 Aluminium Jointing Sleeevs 62 Guard Netting Of 33 Kv Lines 63 Guys For 33 Kv Lines 64 Galvanised Stay Set With 50X8 Mm Stay Clamp, Guy Insulators ( 2 Nos ) , Anchor Plate ( 300X300x8mm ) , Nut Bolts, 2 Nos Turn Buckles, 1.8 M Long, 20 Mm Diameter Solid Gs Stay Rod & 7 / 4.00 Mm Dia Gi Standard Wire Complete. 65 Common Miscellaneous Works 66 Development Of Land 67 Chain Link Fencing Of 33Kv Yard Of Substation By Way Of Mass Concreting In Foundations And Chain Link Fencing Of 6Ft. Height 68 33 / 11Kv Transformer Foundation 69 33Kv Equipment Foundation ( Breakers, Cts / Pts, Isolators, Las ) 70 Earthing Mat ( Gi Flat 50Mm X 8Mm ) 71 33Kv Yard Concreting / Metalling And Laying Of Gravels 20Mm ( Complete Bays ) 72 Yard Lightening ( Complete ) With 4 No. 9 Mtr Long St Poles ( St-410 ) , Sp-33, Fitted With 2 No. 60 W Led Lights On Each Pole, Complete With Control Gear Box, Earthing And Bottoming Of Poles. 73 Rcc Cable Trench ( 1:2:4 ) For Laying Of 11 Kv Xlpe Power Cables And Control Cables From Various Equipments To Control Room & From Control Room To Outgoing Structures Alongwith Rcc Duct Covers. 74 Earthing Electrode ( 3M Long 40Mm Dia Gi Pipe ) Through Gi Strip 75 Common Miscellaneous Equipments 33 / 11Kv Substations 76 A ) . Battery Bank 30 V, 100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type, High Impact Polyprophelenecopolymer Container, Flame Retardant. B ) . 30V, 100 Ah , Float-Cum-Boost Charger With Full Wave Rectification For 220 V, 1Phase, 50 Hz Ac Input Supply . 77 Distribution Panel ( 30 V, Dc ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43 For 2 No Battery Incoming Supply With 2 No 63 Amps Dp Mcbs For Incoming Supply Doublebusbar Of Adequate Size, 12 No Dp Dc Mcb ( 0-32A ) Including Indication Lamps And Cables And Other Accessories 78 Distribution Panel ( 415 V, Ac ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43. 200 Amps Switch Fuse Disconnector For Incoming Supply And 5 No Tpn McbS ( 16-125 Amps ) And 5 No Dp Mcbs ( 0-32A ) , Rectangular Busbar Suitable For 200 Amps Continuous Supply Including Indication Lamps And Cables And Other Accessories 79 Rubber Mat 1Mx2m 3 Mm Thick For 33 Kv 80 Fire Extingiusherco2type Of 4.5 Kg Capacity For Control Room 81 3Sand Bucket Fire Extingiusher 82 Helmet 83 Rubber Gloves For 33 Kv Level 84 Rubber Gloves For 11Kv Level 85 Safety Belt 86 Safety Shoes 87 Hv Detectors For 33 Kv 88 Earthing Rod ( Set Of 3 Rods ) 89 Rmu Along With Out Going Cable 90 33 Kv Ring Main Unit : 3 Way Out Poor Type Rmu, Sf6 Insulated, Extensible Type, At 33 Kv System Voltage And Breaking Capacity 25 Ka For One Second, With Sf6 Circuit Breaker / Vcb Self Powered With O / C+ E / F Relay System Comprsing Of A ) One Nos 33 Kv, 630 Amp. Motorized Isolators Including Earthing Switches With Making Capacity 62.5 Ka, Having Mechnical On / Offb ) Two Nos 33 Kv, 200 Amp Motorized, Spring Operated, Circuit Breakers With Earthing Switchesc ) Cu Bus-Bar Of 630 Amp. Ratingd ) One No Numerical Aux. Self Powered Relay Having Non Directional O / C And E / F Protection ( For Each Circuit Breaker Feeder ) , Relay Should Have Minimum 7-Di & 8-Do. The Relay Shall Also Interface Via An Rs 232 / 485 Port In Orde O Send, As A Minimum, Real Time Readings Using The Modbus Protocol.E ) Incoming Isolators Shall Have Fpi With Electrical Reset Contact / Facility.F ) All Necessary Potential-Free Contacts For Indications Relevent To Rmu Monitoring And Control.G ) Capacitor Voltage Dividers Serving Live-Line Cable Indicators In Each Breaker & Isolator. 91 33 Kv 3 Phase Indoor Terminating Kit To Be Used With Cables-185Mm Sq. 92 33 Kv 3 Phase Out Door Terminating Kit To Be Used With Cables-185Mm Sq. 93 Cable Route Markers 94 Excavation In Any Type Of Soil Including Hard Laterit Soil 95 Refilling Of Excavated Soil 96 Sand For Cushioning Of The Cables In The Trench 97 Cement Tiles Of Size 300 Mm Lengthx 250 Mm Widthx 37 Mm Thick As A Protective Cover For Underground Cables 98 Earthing Of Rmu- Excavation Of Earth Pit Of Dia 650 Mm & Depth 3000 Mm, Installation Of Earthing Pipe Of 40 Mm Nominal Bore & 4 Mm Wall Thickness & Length 2.5 Mtr Long As Per Is 1239. Gi Strip For Neutral Earthing Of Size 75 Mmx10mm & 50 Mm X 6 Mm For Connection Of Rmu Body As Per Is 2629 / 85, Gi Nuts And Bolts, Refilled With Earth Enhancement Materials And Earth Chamber Made Of Brick Masonary With Rcc Slab Cover. 99 Cement Concrete 1:2:4 ( 1 Cement, 2 Coarse Sand, 4 Graded Graniticor Basaltic Stoe Aggregated 40 M Nominal Size Of Foundation ) 100 Centering And Shuttering Including Struttings, Propping Etc. & Removal Of Form Work 101 15 Mm Cement Plaster 1:4 For Foundations. 102 Wire Mesh Boundary Fencing Around The Rmu 103 33 Kv, 3 Core Xlpe Cable Armoured, 185 Mm2 104 Installation Of Capacitor Bank 105 12 Kv, 1.2 Mvar, Capacitor Bank With Vcb Panel With Complete Arrangement For Conection With 11 Kv Incomer Panel , Series Reactor, Isolator, Rvt, Surge Arrestors, Ht Cable With Termination Kits, Control Cables, Crca Cubicle Panel Etc With Structure, Foundation & Accessories. 106 33 Kv Ct / Pt 107 33Kv Ct / Pt Combined Unit, With Ct Ratio 100 / 5 & Ptr 33 Kv / 110 V / V3 , 3-Phase, 50 Hz, Onan Cooled, Outdoor Type. The Combined Unit, Cts And Pts Shall Be As Per Below Specifications.The Rated Burden Of Ct Shall Be 7 Vathe Rated Burden Of Pt Shall Be 20Va Per Phase With Proper Colour Coded Identification. Pts Shall Be Of Uniform Insulating And One Minute Power Frequency Dry Withstand Voltage 70Kv 108 Metering Cubicle For 3Phase 4 Wire Metering System Suitable For 3 Phase, Ht, Tri-Vector Meter With Sealing And Locking Facility Made Of Ms Sheet Steel Thickness Not Less Than 2Mm Duly Power Coat Painted Suitable For Indoor As Well As Outdoor As Per The Site Requirement. The Cubicle Shall Be Painted Through 7-Tank Process. The External Dimensions Should Be Adequate. Provided With Synthetic Or Semi Synthetic Gasket Firmly Glued To The Surface, Dust, Weather Andvermin Proof And Shall Comply Degree Of Protection Ip 65 Both The Chambers Having One Sided Hinged Door Arrangements. The Panel Shall Be Provided With Two No Ms Channels Of Size 100 X 50 Mm On The Front And Rear Sides Duly Welded And 4 No Of Lifting Hooks. It Should Be Possible To Take Meter Reading Manually, Through Cmri And Computer Without Opening Door. Including Supply And Fixing Of 75Mm Gi Pipe Between Ct / Pt Combined Unit And Metering Cubicle For Ct / Pt Wiring To Tri-Vector Meter. 109 Gichannel & Angle For Mounting Ct Pt Combined Units With Nuts And Bolts ( Size 100 X 50 X 5 Mm ) 110 3Ph4 Wire Ht Ct / Pt Operated Fully Static Smart Tri-Vector Energy Meters Dlms Compliant Category C With Rs232 Port . 33Kv / V3 / 110V / V3, Ph-N ( 3P, 4W ) Meters For Measurement Of Different Electrical Parameters Including Active Energy ( Kwh / Mwh ) , Reactive Energy ( Kvarh / Mvarh ) , Apparent Energy ( Kvah / Mvah ) Etc. ( Make L&T, Secure Or Abb ) . 111 Pvc Copper Wire Flexible Multi-Strand Of Required Size For Secondary Connections For Ct Wiring The Minimum Wire Size Shall Be 4 Mm2 ( Ryb ) And For Pt Wiring Minimum Wire Size Shall Be 2.5 Mm2 ( Ryb ) . 112 Copper Lugs Preferably Ring Type Duly Crimped For Termination Of Wires And Tapes 113 Acsr Jumpers With Hardware Fittings Like Acsr To Ct / Pt Unit Bush Clamp, Other Hardwares As Per Site Requirement 114 Earthing 40 Mm Gi Pipe Or 20 Mm Gi Rod, 2.5 Mtr For Ct / Pt Combination Unit. Earthing Of Metering Cubicle Through Two No 25 X 5 Mm Flat Iron. 115 11 Kv Indoor Switchgear 116 11 Kv Vcb Panel Board ( 12 Kv, 1250A, 25 Ka, Outdoor ) With O / C, E / F Relays ( Iec61850 ) , Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant With Rs-485 Port ( 1 Incomer & 3 Outgoing ) 117 11 Kv Bus Coupler Along With Adaptor Panel 118 11Kv, Gapless Surge Arrestor, 9 Kv , 10 Ka , La With Polymer Housing, Stn. Type ( 4 / 5 / 6 Sets ) 119 100 Kva, 11 / 0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound ) 120 11 Kv Isolater, Double Break, 3-Pole, 600 Amp, Horizental Mounting Type With Earth Switch 121 11Kv Horn Gap, 3-Phase, 3-Pole, 200 Amp 122 Pvc Armoured Cable ( Lt ) , 120Mm2 ( 3.5 Core ) 123 St Poles ( St-410 ) , Sp-33, 9 Mtrs.Long ( For 4 No. O / G Structures And 2 No. Aux Sub Station ) 124 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum Per Pole 125 Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip 126 Mccb-200 Amp With Enclosure 127 Galvanisedironoff Sorts 128 Earthing Of 100Kva Substation --Excavation Ofearth Pit Of Dia650 Mm & Depth 3000 Mm, Installation Ofearthing Pipe Of 40 Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr Long As Per Is 1239.Gi Strip For Neutral Earthing Of Size 75 Mm X10 Mm& 50 Mm X 6 Mmfor Connection Of Transformer Body, G.O Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts, Refilled With Earth Enhancement Materials And Earth Chamber Made Of Brick Masonary With Rcc Slab Cover. 129 11 Kv Xple Power Cables 130 11 Kv, 630 Mm² Single Core Xlpe Armoured, Frls. ( With One Spare Length ) 131 11 Kv, 3- Core, Xlpe 185 Mm² Armoured, Frls, 132 11 Kv Indoor Heat Shrinkabler Cable Termination Kits For 630 Mm Sq. Single Core Cable. Id / Od 133 11 Kv Outdoor Heat Shrinkabler Cable Termination Kits For 185 Mm Sq. Three Core Cable. Id / Od
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Jammu And Kashmir View Result →
49.
Rural Development #10634145 Price Bid
Supply Of Various Types Of Construction Materials Grampanchayat Pendhari Tah . Lakhani Dist Bhandara . , Construction , 80 Mm . Metal White- ( Hand Broken Metal ) , 40 Mm Metal White- ( Crusher Broken Metal ) , 40 Mm Metal Black- ( Hand Broken Metal ) , 30 Mm Metal Black- ( Crusher Broken Metal ) , 20 Mm Metal Black- ( Crusher Broken Metal ) , 12 Mm Metal Black- ( Crusher Broken Metal ) , 2 To 5 Mm Fine ( Churi ) Black- ( Crusher Broken Metal ) , Boulders Rubbles And Masonary Stones , Sand River ( Unscreen ) , Sand ( Nallah Bed ) , Soft Murum , Hard Murum , Soil , Cement 53 Grade Opc , Cement 53 Grade Ppc , Burnt Bricks ( Ii Class ) , Ash Bricks ( Ii Class ) , Mild Steel Bars 6 Mm , Mild Steel Bars 8 Mm , Mild Steel Bars 10 Mm , Mild Steel Bars 12 Mm , Tmt Steel Bars 8 Mm , Tmt Steel Bars 10 Mm , Tmt Steel Bars 12 Mm , Vetrified Tiles ( 2 X 2 Ft ) , Chemical Flush Door , Plastic Emulsion Paint , Distemper , Birla White , Toilet Sheet ( With Acceseries ) , Rcc Chair , Teak Wood Door , Paving Block Colour Coated , Steel Door , Teen Sheet , Mixture Machine Rent , Wastege Material Carting Charges , Murum Carting , Centring Tar , Water Tanker Charges , Centring Charges , Bitumen Pack Tin 60/70 At Mumbai , Ferlong Stone , Steel Grill Work , 300 Mm Dia Cement Concrete Pipe With Coller , 450 Mm Dia Cement Concrete Pipe With Coller , 600 Mm Dia Cement Concrete Pipe With Coller , 800 Mm Dia Cement Concrete Pipe With Coller , 1000 Mm Dia Cement Concrete Pipe With Coller , 1200 Mm Dia Cement Concrete Pipe With Coller , Pvc Pipe 63Mm With Socket , Pvc Pipe 75Mm With Socket , Pvc Pipe 90Mm With Socket , Pvc Pipe 110Mm With Socket , Pvc Pipe 150Mm With Socket , Pvc Pipe 250Mm With Socket , Pvc Pipe 300Mm With Socket , Murum Carting For Narega , Rollar Per Day , Jcb , Water Supply , Ci Double Flanged Pipes 80 Mm , Ci Double Flanged Pipes 100 Mm , Ci Double Flanged Pipes 125 Mm , Ci Double Flanged Pipes 150 Mm , Pvc Pipe 63 Mm 4Kg . /Sq . Cm , Pvc Pipe 75 Mm 4Kg . /Sq . Cm , Pvc Pipe 90 Mm 4Kg . /Sq . Cm , Pvc Pipe 110 Mm 4Kg . /Sq . Cm , Pvc Pipe 140 Mm 4Kg . /Sq . Cm , Pvc Pipe 160 Mm 4Kg . /Sq . Cm , Pvc Pipe 180 Mm 4Kg . /Sq . Cm , Pvc Pipe 200 Mm 4Kg . /Sq . Cm , Pvc Pipe 63 Mm 6Kg . /Sq . Cm , Pvc Pipe 75 Mm 6 Kg . /Sq . Cm , Pvc Pipe 90 Mm 6 Kg . /Sq . Cm , Pvc Pipe 110 Mm 6 Kg . /Sq . Cm , Pvc Pipe 140 Mm 6 Kg . /Sq . Cm , Pvc Pipe 160 Mm 6 Kg . /Sq . Cm , Pvc Pipe 180 Mm 6 Kg . /Sq . Cm , Pvc Pipe 200 Mm 6 Kg . /Sq . Cm , G . I . Pipe 50 Mm Medium , G . I . Pipe 65 Mm Medium , G . I . Pipe 80 Mm Medium , G . I . Pipe 100 Mm Medium , G . I . Pipe 125 Mm Medium , G . I . Pipe 150 Mm Medium , G . I . Pipe 50 Mm Heavy , G . I . Pipe 65 Mm Heavy , G . I . Pipe 80 Mm Heavy , G . I . Pipe 100 Mm Heavy , G . I . Pipe 125 Mm Heavy , G . I . Pipe 150 Mm Heavy , Hdpe Pipe 63 Mm 6Kg/Cm , Hdpe Pipe 75 Mm 6Kg/Cm , Hdpe Pipe 90 Mm 6Kg/Cm , Hdpe Pipe 110 Mm 6Kg/Cm , Hdpe Pipe 125 Mm 6Kg/Cm , Hdpe Pipe 140 Mm 6Kg/Cm , Hdpe Pipe 160 Mm 6Kg/Cm , Hdpe Pipe 63 Mm 8Kg/Cm , Hdpe Pipe 75 Mm 8Kg/Cm , Hdpe Pipe 90 Mm 8Kg/Cm , Hdpe Pipe 110 Mm 8Kg/Cm , Hdpe Pipe 125 Mm 8Kg/Cm , Hdpe Pipe 140 Mm 8Kg/Cm , Hdpe Pipe 160 Mm 8Kg/Cm , Mdpe Pipe 25 Mm , Mdpe Pipe 32 Mm , Mdpe Pipe 40 Mm , Mdpe Pipe 50 Mm , Cidf Reflux Valves 50 Mm , Cidf Reflux Valves 65 Mm , Cidf Reflux Valves 80 Mm , Double Flange Sluice Valves 50 Mm , Double Flange Sluice Valves 65 Mm , Double Flange Sluice Valves 80 Mm , Double Flange Sluice Valves 100 Mm , Double Flange Sluice Valves 125 Mm , Double Flange Sluice Valves 150 Mm , Air Valves 50 Mm Pn-1 , Copper Lightening Conductor , M . S . Ladder , Water Level Indicator Upto , Pump 100 Mm Dia 1 . 5 Hp , Pump 100 Mm Dia 2 . 0 Hp , Pump 100 Mm Dia 2 . 5 Hp , Pump 100 Mm Dia 3 . 0 Hp , Pump 100 Mm Dia 4 . 0 Hp , Pump 100 Mm Dia 5 . 0 Hp , Pump 150 Mm Dia 1 . 5 Hp , Pump 150 Mm Dia 2 . 0 Hp , Pump 150 Mm Dia 3 . 0 Hp , Pump 150 Mm Dia 4 . 0 Hp , Pump 150 Mm Dia 5 . 0 Hp , Pump 150 Mm Dia 6 . 0 Hp , Pump 150 Mm Dia 7 . 5 Hp , 3 Core 2 . 5 Sq . Mm . Insulated Flat Flexible Submersible Cable , 3 Core 4 Sq . Mm . Insulated Flat Flexible Submersible Cable , 3 Core 6 Sq . Mm . Insulated Flat Flexible Submersible Cable , Triple Pole Metal/ Iron Clad Switch , 3 Pilot Lamps , Voltmeter , Ammeter , Star Delta Starter Upto 7 . 5 , Dol Starter Upto 7 . 50 , Earthing With Galvanized Cast Iron Earth Plate Size 60 X 60 X 0 . 6 Cm , Panel Board
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
50.
Communications and Information Technology  #10627586 Price Bid
Rate Contract For Call Basis Maintenance And Shifting Of Diesel Engine Alternator Sets At Various Te /Bts Sites Under Ssa Banswara . Maintenance And Shifting Of Diesel Engine Alternator Sets , Pdg & Making Of General Servicing Of The Following Capacity E/A Sets Of Different Make And Model Installed At Te/Bts Sites Comprising Of Following Jobs I/C Fare And Labour Charge I/C Complete Checking Of E/A Set After Servicing And Replacement Of Consumables For Proper Working As Per Manufacturer Recommendations Etc . Complete As Reqd . A ) Cleaning The Bowl Inside As Well As Out Side Of Fuel Filter And Oil Filter , Replacement Of Sealing Ring . B ) Cleaning The Fuel Strainer With Clean Diesel I/C Pressure Testing Of Fuel Injector And It Should Be As Per Manufacturer Recommendation . C ) Cleaning The Cooling System ( Raditor ) D ) Replacement Of Air Cleaner Element If Reqd . E ) Checking All Belt Drives And Retensioning The Same Etc As Reqd . F ) Remove The Tapet Cover And Checking The Valve Clearance Gap Between Rocker Arm Toe And Valve Stem End In Cold Condition As Per Manufacturer Recommendation I/C Replacement Of Tappet Cover Gasket If Reqd . Etc . As Reqd . G ) Cleaning The Entire E/A Set ( Inclusive Of Fins , Blower And Block ) . I . E . Oil & Grease Etc . H ) Cleaning Of Diesel TankI ) Checking Of Charging Alternaror , Starter Self And Engine Control Panel Connection , Gauges And Indicators And Its Fuction . J ) Checking And Setting Of Fuel Supply And Time As Per Manufacturer Recommendations . Note: After Servicing The Set , A Trial Test Also Be Carried Out By The Firm For 30 Minutes And Check Its Performance & Submitt The Readings Of Out Put Voltage , Current ( For Each Phase ) And Frequency , Lop , Rpm , Hr Meter Reading With Working Condition Status Report Etc . In Service Report . This Item Shall Be Paid Only After Submission Of Desired Report Duly Verified By Concerned Telecom Authorities . , Up To 20 Kva Dea Set , Above 20 Kva And Up To 50 Kva , Replacement Of The Following Parts / Items In Existing Various Capacity E/A Sets Up To 50 Kva Of Different Make , Model I/C Dismentling Of Faulty Parts , Fixing The New In Place Of Faulty Parts , Testing Etc As Reqd . ( Note- Make And Model As Per Manufacturer Recommendation ) , Lub Oil Filter Element , Diesel Filter Kit , Radiator Coolent Pre Mix Ready To Use ( Make -Kirloskar /Hp/Fleetguard ) , Lubricating Oil Multi Grade ( 20W40 ) ( Make -Koil /Servo/Hp/Volvoline ) , Steel Wire Braided Fuel Pipe With Benjo Bolts & Washer , Battery Leads Red & Black Standard Length & Size Suitable Up To 180Ah Battery I/C Brass Terminals , Battery Lead Brass Terminals/Copper Lugs , Replacement Of The Following Parts/Items In Existing E/A Set Amf / Manual Control Panels I/C Dismentling Of Faulty Parts , Fixing The New In Place Of Faulty Parts , Testing Etc As Reqd . ( Note- Make And Model As Per Manufacturer Recommendation ) , Solid State Smps Or Scr Based Battery Chargers Suitable Up To 12V , 180 Ah Battery ( Make -Technika Or Similar Superior Make ) , Servicing Of The Self Starter Of Dea Set I/C Dismantling , Cleaning Of Self With Petrol , Greasing And Oiling Of Bearing I/C Testing Etc Complete As Reqd . Note-This Item Exclude The Cost Of Parts Associated With Self Starter . , Repairing Of Following Faulty Items In The Self Starter Of Dea Set I/C Dismantling Of Unserviceable/ Defective Items , Fixing With New One I/C Connection , Testing Etc Complete As Reqd . [Note: Labour Charges Already Covered In Item No 4] , Carbon Bush Set , Solenoid Coil , Bendex Gear , Servicing Of Battery Charging Alternator / Dynamo I/C Dismantling Of Equipment , Cleaning , Greasing And Oiling Of Bearings And Other Parts Etc . Complete As Required . Note-This Item Exclude The Cost Of Parts Associated With Self Starter . , Repairing Of Following Faulty Items In Battery Charging Alternator / Dynamo Of Dea Set Dea Set I/C Dismantling Of Unserviceable/ Defective Items , Fixing With New One I/C Connection , Testing Etc Complete As Reqd . [Note: Labour Charges Already Covered In Item No 06] , Rectifier Assembly , Carbon Brush Set , Supplying And Fixing Of 12 Volts Maintenance Free Battery Of Following Capacity For E/A Sets , I/C Initial Charging , Battery Terminals , Transportation , Testing , Commissioning Etc . Complete As Reqd . ( Note: Battery Should Be Of Atleast 24 Months Warranty ( 18 Month Full Replacement +6 Month Prorata Basis ) . Manufacturer Warranty Card With Dealer Stamp Shall Be Submitted Along With New Battery ) . , 90 Ah , 130 Ah , Transportation Charges For Alternator Up To 50 Kva Capacity From Site To Workshop & Back After Repairing I/C Dismantling , Loading , Unloading , Transportation , Safe Handling & Commissioning After Repairing Etc . Complete As Reqd . , Rewinding Of Following Parts Of Existing Alternator Up To 20 Kva With Suitable Size Copper Enamelled Wire Including Providing Of Insulation Of Appropriate Class , Varnishing , Assembling I/C Testing Etc Complete As Required . , Main Stator Winding , Main Rotor Winding , Exciter Stator Winding , Exciter Rotor Winding , Replacement / Repairing Of Faulty Items In The Existing Alternator Up To 50 Kva Alternator At Te / Bts Sites I/C Dismantling The Faulty , Replacement By New One I/C Fixing , Testing , Commissioning Etc . Complete As Reqd . , Avr Make National /Crompton/Kirloskar , Power Diode For Rotating Rectifier Assembly , Supplying Of Following Size Of Pvc Insulated Pvc Sheathed 1 . 1 Kv Grade Aluminium Conductor Armoured Cable Confirming To Relevant Is-Specification Etc Complete As Reqd . ( Make -Polycab/Havells/Finolex ) , 2 X 16 Sqmm . , 4 X 16 Sqmm . , Laying Of One No . Pvc Insulated & Pvc Sheathed/Xlpe Power Cable Of 1 . 1 Kv Grade Of Following Size . Direct In Ground I/C Excavation , Sand Cushioning , Protective Covering And Refilling The Trench Etc . As Reqd . , Up To 35 Sq . Mm , Laying Of One No . Pvc Insulated Pvc Sheathed/Xlpe Power Cable Of 1 . 1 Kv Grade Of Following Size In The Existing Rcc/Hume/ Stoneware/Metal Pipe As Reqd . , Up To 35 Sq . Mm , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1 . 1 Kv Grade Of Following Size On Surface As Required . , Up To 35 Sq . Mm ( Clamped With 1Mm Thick Saddle ) , Supplying And Making End Termination With Brass Compression Gland & Aluminium Lugs For Following Size Of Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1 . 1Kv Grade As Reqd . , 2 X 16 Sq . Mm ( 22Mm ) , 4 X 16 Sq . Mm ( 28Mm ) , Providing And Fixing 6 Swg Dia G . I . Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Sub Main Wiring / Cable As Required . , S/F Of 63 Amps Four Pole On Load Change Over Switch In Steel Enclosure With Side Handle Operation Capable Of Working 415/500 V , Ac 23 Duty I/C Drilling Hole On The Board , Making Connection , Earthing The Body Etc . As Reqd . , S/F 63 Amps Heavy Duty Double Break Tpn Switch Fuse Unit With Hrc Fuses In Steel Enclosure With Side Handle Operation Capable Of Working 415/500 V Ac 23 Duty I/C Drilling Hole On The Board , Making Connection , Earthing The Body Etc . As Reqd . , S/F Of 100 Amps Four Pole On Load Change Over Switch In Steel Enclosure With Side Handle Operation Capable Of Working 415/500 V I/C Drilling Hole On The Board , Making Connection , Earthing The Body Etc . As Reqd . , S/F 100 Amps Heavy Duty Double Break Tpn Switch Fuse Unit With Hrc Fuses In Steel Enclosure With Side Handle Operation Capable Of Working 415/500 V I/C Drilling Hole On The Board , Making Connection , Earthing The Body Etc . As Reqd . , Dismentling Of Existing Silent Canopy /Open Type Dea Set Of Capacity Up To 30 Kva Of Differen
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
TenderDetail
Loading tenders