View Bid Results For Pre Paid Meter Tenders

We found 1251 Bid Results related to pre paid meter tenders. You can find Contractor details who won pre paid meter tenders along with contract details in Bid awards announcements section.

Filters
Stage
918
208
125
Tender Publishing Platform
17
1234
State / UT
36
182
166
124
87
66
65
61
55
54
52
46
45
41
24
22
21
18
17
13
13
11
11
10
8
7
7
6
5
4
3
2
1
1
1
1
1
Contract Value
339
83
584
244
Publish Date
0
0
0
0
0
Sector
26
639
196
88
58
55
48
40
22
15
14
12
12
8
7
7
7
6
3
3
2
2
2
2
1
1
1
Ownership
5
647
443
85
71
5
Within keyword
Active filters:
Showing 1–26 of 1251 tenders matching your filters
1.
Public Administrative Department #11325175 AOC
Tender for Providing And Laying In Position Cment Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering- All Work Up To Plinth Level: (Dsr No. 4.1) , 1:2:4 (1 Cement: 2 Coarse Sand (Zone-Iii) Derived From Natural Sources: 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) (Dsr No. 4.1.3) , 6 Mm Cement Plaster 1:3 (1 Cement : 3 Fine Sand) Finished With A Floating Coat Of Neat Cement And Thick Coat Of Lime Wash On Top Of Walls When Dry For Bearing Of Reinforced Cement Concrete Slabs And Beams (Dsr No. 13.17) , Dismantling Of Flushing Cistern Of All Types (C.I./Pvc/Victirous China) Including Stacking Of Useful Materials Near The Site And Disposal Of Unserviceable Materials Within 50 Meters Lead. (Dsr No.15.52) , Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials Including Malba All Complete As Per Directions Of Engineer-In-Charge (Dsr No. 14.82) , Providing And Fixing Grab Rail Of Stainless Steel Pipe 1-1/4 And Fitting Of Grade Aisi 304 As Per Jis Standard 3448 Including Fitting And Fixing Of Pipe With Clamps At 1.00 M Spacing Including Cutting And Making Good The Walls Complete As Per Direction Of Engineer-In-Charge. (Nsi) , Providing And Fixing Flat Pressed Three Layer Particle Or Graded Plain Wood Board Medium Density Exterior Grade (Grade I) Fpt-I, Conforming And Marked To Frame, Backing Or Studding With Screws Etc. Complete (Frames, Backing Or Studding To Be Paid Separatley. (Dsr No. 9.17) , 12 Mm Thick (Dsr No. 9.17.1) , Providing And Fixing P.V.C. Low Level Flushign Cisern With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete (Dsr No. 17.18) , 10 Litre Capacity - White (Dsr No. 17.81.1) , Providing And Fixing Solid Plastic Seat With Lid For Pedestal Type W.C. Pan Complete: (Dsr No. 17.20) , White Solid Plastic Seat With Lid (Dsr No. 17.20.1) , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. (Dsr No. 17.28) , Flexible Pipe (Dsr No. 17.28.2) , 32 Mm Dia (Dsr No. 17.28.2.1) , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Swashers Complete. (Dsr No. 17.31) , Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931: (Dsr No. 18.49) , 15 Mm Nominal Bore (Dsr No. 18.49.1) , Providing And Fixing C.P. Brass Long Body Bid Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms. (Dsr No. 18.51) , 15 Mm Nominal Bore (Dsr No. 18.51.1) , Providing And Fixing C.P. Brass Angle Valve For Basin Mixer Ad Geyser Points Of Approved Quality Conforming To Is: 8931 (Dsr No. 18.53) , 15 Mm Nominal Bore (Dsr No. 18.53.1) , Providing And Fixing C.P. Brass Extension Nipple (Size 15 Mm X 50 Mm) Of Approved Make And Quality Make And Quality As Per Direction Of Engineer-In-Charge (Dsr No. 18.53 A) , Providing And Placing On Terrace (At All Floor Levels) Polythylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangements And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank.(Dsr No. 18.48) , Providing And Fixing Ptmt Pillar Cock Of Approved Quality And Colour. (Dsr No. 18.56) , 15 Mm Nominal Bore, 125 Mm Long Foam Flow, Weighing Not Less Tha 120 Gms. (Dsr No. 18.56.2) , Providing And Fixing 8 Mm Dia C.P./ S.S. Jet With Flexible Tube Upto 1 Meter Long With S..S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer- In-Charge (Dsr No. 17.16A) , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions: (Dsr No. 18.21) , 45 Cm Length (Dsr No. 18.21.2) , 15 Mm Nominal Bore (Dsr No. 18.21.2.1) , Regarding Terracing Of Mud Phaska Covered With Tiles Or Brick, In Cement Mortar By Dismantling Tiles Or Bricks, Removing Mud Plaster, Preparing The Surface Of Mud Phaska To Proper Slope, Relaying Mud Plaster Gobri Leaping And Tiles Or Bricks, Grouted In Cement Mortar 1:3 (1 Cement: 3 Fine Sand), Including Replacing Unserviceable Tiles Or Bricks With New Ones And Disposal Of Unserviceable Material To The Dumping Ground (The Cost Of The New Tiles Or Brick Excluded), All Complete As Per Direction Of Engineer-In-Charge. (Dsr No. 14.13) , Making Khurras 45 X 45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size) Over P.V.C. Sheet 1M X 1M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 (1 Cement : 3 Coarse Sand) And A Coat Of Neat Cement, Rounding The Edges And Making And Finishing The Outlet Complete (Dsr No. 12.22) , Providing And Fixing Led Tubelight Complete In All Respects. Make: Havells/Phillips/Usha (Nsi) , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacturer Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour (Dsr No. 13.81) , Old Work (One Or More Coats (Dsr No. 13.81.1) , Finishing Walls With Acrylic Smooth Exerior Paint Of Required Shade: (Dsr No. 13.111) , Old Work (Two Or More Coat Applied @ 1.67 Ltr/ 10 Sqm) On Existing Cement Paint Surface (Dsr No. 13.111.1) , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. (Dsr No. 18.12) , 25 Mm Dia Nominal Bore (Dsr No. 18.12.3) , Providing And Fixing Gun Metal Gate Valve C.I. Wheel Of Approved Quality (Screwed End) : (Dsr No. 18.17) , 25 Mm Nominal Bore (Dsr No. 18.17.1) , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Andic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete: (Dsr No. 9.97) , 200X10mm (Dsr No. 9.97.3) , Providing And Fixing And Installation Of Ventilation Ms Exhaust Fan 300 Mm With Frame, Nut, Bolt Etc Make Khaitan, Havells/Crompton/Gec Complete In All Respect As Per The Satisfaction Of Engineer In Charge (Nsi) , Providing And Fixing The Louvers Complete With Frame For Exhaust Fan Of 12 Diameter (Nsi) , Providing And Fixing And Installation Of Double Ball Bearing Ceilig Fan 48 Make Kahitan, Havells, Orient, Crompton Complete In All Respects As Per The Satisfaction Of Engineer-In-Charge (Nsi) , Replacement And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New York): (Dsr No. 18.46) , 15 Mm Nominal Bore (Dsr No. 18.46.1) , Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete (Dsr No. 13.88) , Providing And Applying White Cement Bases Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. (Dsr No. 13.80) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Includig Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: (Nsi Based Dsr No. 17.1) , White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests (Nsi Based Dsr No. 17.1.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closed (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required (Nsi Based Dsr No. 17.2) , W.C. Pan With Isi Marked White Solid Plastic Seat And Lid (Nsi Based Dsr No. 17.2.1) , Providing And Fixing Of Pvc Pipe Including Specials Labour For Fixing Treching Refilling Pvc Solvent And Testing As Per Satisfaction Of Eic (Nsi) , 2 Dia, Pvc Pipe, Make: Prince/Diplast/Supreme/Finolex (Nsi) , Providing And Fixing Pv Fitting Including Labour And Refilling Pvc Solvent And Testing As Per Satisfaction Of Eic (Nsi) , Single Tee Size 50X50x50 Mm (Nsi) , Bend 87.5 Degree Size 50 Mm Bend (Nsi) , Providing And Fixing Ptmt Grating Of Approved Quality And Colour (Dsr No. 18.58) , Circular Type (Dsr No. 18.58.1) , 125 Mm Nominal Dia With 25 Mm Waste Hole (Dsr No. 18.58..1.2) , Providing And Fixing 50 Watt Led Flood Light With Bracket Outside On The Wall Complete In All Respects (Nsi) , Wiring For Light Point/Fan Point/ Exhaust Fan Point/Call Bell Point With 1.5 Sq. Mm Frls Pvc Insulated Coppre Condctor Single Core Cable In Surface/Recessed Medium Class Pvc Conduit, With Modular Weith, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Counductor Single Core Cabe Etc. As Required. (Dsr Elec. No. 1.3.1) , Supplying And Fixing Following Modular Switch/Socket On The Existing Modular Plate & Switch Box Including Connections Excluding Modular Plate Etc. As Required. (Dsr Elec No. 1.24) , 15/16 A Socket Outlet (Dsr Elec No. 1.24.3) , 6 Pin 15/16 A Socket Outlet (Dsr Elec. No. 1.24.5) , Providing And Fixing In Position Pre-Cast Reinforced Cement Concrete Manhole Cover And Frame Of Required Shape And Approved Quality (Dsr No. 19.19) , Hd- 20 (Dsr No. 19.19.2) , Square Shape 450 Mm Internal Dimension (Dsr No. 19.19.2.1) , Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete: (Dsr No. 18.18) , 20 Mm Nominal Bore (Dsr No. 18.18.2) , Providing And Fixing Cp Flange Isi Marked 15 Mm Complete In All Respects (Nsi) , Providing And Fixing Ptmt. Push Cock Of Approved Quality And Colour (Dsr No. 18.57) , 15 Mm Nominal Bore, 98 Mm Long, Weighing Not Less Than 110 Gms. (Dsr No. 18.57.1) , Providing And Fixing Ptmt 15 Mm Urinal Spreader Size 95X69x100 Mm With 1/2 Bsp Thread And Shapes, Weighing Not Less Than 60 Gms. (Dsr No. 17.75) , Providing And Fixing Of 32 Mm C.P. Brass Waste Of Standard Pattern Complete In All Respect (Nsi) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is : 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom, And Sides Wih Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminum Snap Beading For Glazing/ Panellig, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Panelling And Dash Fasteners To Be Paid For Separately) : (Dsr No. 21.1) , For Fixed Portion (Dsr No. 21.1.1) , Anodised Aluminum (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Aodic Coating Of Grade Ac 15) (Dsr No. 21.1.1.1) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Wherever Required: (Dsr No. 17.5) , Single Half Stall Urinal With 5 Litre P.V.C. Automatic Flushing Cistern (Dsr No. 17.5.1) , Providing And Fixing Of Sub Boards Of Various Sizes With Remark Printing, Lamination Etc. Complete In All Respects (Nsi) , Sun Board Printing With Lamination 5 Mm Sun Bouard Size 12 X 12 (Nsi) , Sun Board Printing With Lamination 5 Mm Sun Bouard Size 12 X 18 (Nsi) , Sun Board Printing With Lamination 5 Mm Sun Bouard Size 72 X 24 (Nsi) , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete (Dsr No. 13.91) , Providing And Fixing Sanitary Napkin Vending Machine, Incinerator, Battery And Happy Days Pad Complete In All Respects (Heavy Duty, Superior Quality, Isi Marked) (Nsi) , Note: Credit Against Old Material To Be Taken As Per Actual I.E. (I) Old Plastic @ Rs. 20/Kg (Ii) Old Ms Scrap @ Rs. 35/Kg (Iii) Old Aluminium Doors & Windows @ Rs. 200/Kg
Contract Date: Jun 22, 2026 Contract Value : 2.52 Lakh
Local Bodies No of Bidders 4
2.
Heavy Industries and Public Enterprises #11307960 Technical Bid
Tender for Inviting Rates For Spare Parts And Repairing/Servicing Of Laptop/Computer/Printer/Ups, Different Types Of Cable For Computer Hardware, Stationary Items, General Items, Printer Cartridge, Photocopy And Rented Vehicle & Coolers. , Head Name - Computer Hardware , Com&Lap - Antivirus 1 Years , Com&Lap - Antivirus 3 Years , Com&Lap - Bios Battery , Com&Lap - C - Port To Hdmi , Com&Lap - C - Port To Lan , Com&Lap - Cabinet - Atx , Com&Lap - Cordless Keyboard , Com&Lap - Cordless Mouse , Com&Lap - Cpu Cooling Fan , Com&Lap - Desktop Computer Ram Ddr21gb , Com&Lap - Desktop Computer Ram Ddr22gb , Com&Lap - Desktop Computer Ram Ddr24gb , Com&Lap - Desktop Computer Ram Ddr32gb , Com&Lap - Desktop Computer Ram Ddr34gb , Com&Lap - Desktop Computer Ram Ddr48gb , Com&Lap - Desktop Harddisk 128 Gb , Com&Lap - Desktop Harddisk 256 Gb , Com&Lap - Desktop Harddisk 512 Gb , Com&Lap - Desktop Harddisk 1Tb , Com&Lap - Desktop Mother Board Board 945 , Com&Lap - Desktop Mother Board I3 , Com&Lap - Desktop Mother Board I5 , Com&Lap - Desktop Mother Board I7 , Com&Lap - Desktop Processor C2d , Com&Lap - Desktop Processor Dual Core , Com&Lap - Desktop Processor I3 , Com&Lap - Desktop Processor I5 , Com&Lap - Desktop Processor I7 , Com&Lap - Dvd Writter For Desktop , Com&Lap - Formating Charges , Com&Lap - Keyboard - Pin , Com&Lap - Keyboard - Usb , Com&Lap - Lan Card (Usb To Lan) , Com&Lap - Laptop Battery , Com&Lap - Laptop Charger , Com&Lap - Laptop Dvd Writter , Com&Lap - Laptop Harddisk 128 Gb , Com&Lap - Laptop Harddisk 256 Gb , Com&Lap - Laptop Harddisk 512 Gb , Com&Lap - Laptop Harddisk 1Tb , Com&Lap - Laptop Keyboard , Com&Lap - Laptop Processor & Board , Com&Lap - Laptop Ram Ddr2 1 Gb , Com&Lap - Laptop Ram Ddr2 2 Gb , Com&Lap - Laptop Ram Ddr2 4 Gb , Com&Lap - Laptop Ram Ddr3 2 Gb , Com&Lap - Laptop Ram Ddr3 4 Gb , Com&Lap - Laptop Ram Ddr4 4 Gb , Com&Lap - Laptop Ram Ddr4 8 Gb , Com&Lap - Laptop Touchpad , Com&Lap - Mouse Pad , Com&Lap - Mouse- Pin , Com&Lap - Mouse - Usb , Com&Lap - Pce Lan Card , Com&Lap - Pendrive 32 Gb , Com&Lap - Pendrive 64 Gb C Type Usb3.0 Otg , Com&Lap - Pendrive 64 Gb , Com&Lap - Smps 450W , Com&Lap - Smps 650W , Com&Lap - Smps Slim 450W , Com&Lap - Ssd 256 Gb Laptop And Desktop , Com&Lap - Ssd 512 Gb Laptop And Desktop , Com&Lap - External Ssd 256 Gb For Laptop And Desktop , Com&Lap - External Ssd 512 Gb For Laptop And Desktop , Com&Lap - External Ssd 1 Tb For Laptop And Desktop , Com&Lap - External Ssd 2 Tb For Laptop And Desktop , Com&Lap - External Ssd 4 Tb For Laptop And Desktop , Com&Lap - Ssd Nvme 256 Gb Laptop And Desktop , Com&Lap - Ssd Nvme 512 Gb Laptop And Desktop , Com&Lap - Ssd Nvme 1 Tb Gb Laptop And Desktop , Com&Lap - Usb Extension 4 Port , Com&Lap - Crt Est , Com&Lap -Crt Memory Ic Chip , Com&Lap - Crt Picture Tube , Com&Lap -Crt Power Supply Unit , Com&Lap -Crt Repairing & Service Charge , Com&Lap - Tft Picture Gum , Com&Lap - Tft Power Supply Unit , Com&Lap -Tft Repairing & Service Charge , Com&Lap - Tft Screen , Com&Lap - Cat6 Cable , Com&Lap - Convertor Hdmi To Vga , Com&Lap - Convertor Vga To Hdmi , Com&Lap - Power Cable For Desktop , Com&Lap - Power Cable For Laptop , Com&Lap - Power Cable For Printer , Com&Lap - Data Cable For Printer , Com&Lap - Vga Cable For Desktop , Com&Lap - Hdmi Cable 1 Mtrs , Com&Lap - Hdmi Cable 3 Mtrs , Com&Lap - Hdmi Cable 5 Mtrs , Com&Lap - Hdmi Cable 10 Mtrs , Com&Lap - Hdmi Cable 15 Mtrs , Com&Lap - Hdmi Cable 30 Mtrs , Com&Lap - Wifi Usb Mini Adapter , Usb To Rj 45 Ethernet Lan Adopter , C Type To Rj 45 Ethernet Lan Adopter , Com&Lap - Ms Office Home & Student 2021 , Com&Lap - 19 Inch Monitor (Tft) , Com&Lap - 27 Inch Monitor (Led) , Entry Level Printer - Adf Pickup Pad , Entry Level Printer - Drum Unit , Entry Level Printer - Ccd Unit , Entry Level Printer - Cap Hinges , Entry Level Printer - Control Pannel , Entry Level Printer - Dc Controller , Entry Level Printer - Drum Blade , Entry Level Printer - Fuser Unit , Entry Level Printer - Fuserdrum Gear , Entry Level Printer - Gear Assembly Unit , Entry Level Printer - Hbps Card , Entry Level Printer - Heat Roller , Entry Level Printer - Logic Card , Entry Level Printer - Lsu Unit , Entry Level Printer - Megnet , Entry Level Printer - Motor , Entry Level Printer - Paper Tray , Entry Level Printer - Pick Pad , Entry Level Printer - Pressor Roller , Entry Level Printer - Repairing & Service Charhes , Entry Level Printer - Scanner Unit , Entry Level Printer - Sensor Unit , Entry Level Printer - Sepration Paid , Entry Level Printer - Smps , Entry Level Printer - Teflon , Entry Level Printer - Solenoid (Relay) , Mfd Printer - Adf Pickup Roller , Mfd Printer - Drum Unit , Mfd Printer - C.C.D Unit , Mfd Printer - Cap Hinges , Mfd Printer - Control Pannel , Mfd Printer - Dc Controller , Mfd Printer - Drum Blade , Mfd Printer - Fuser Unit , Mfd Printer - Fuserdrum Gear , Mfd Printer - Gear Assembly Unit , Mfd Printer - Hbps Card , Mfd Printer - Heat Roller , Mfd Printer - Logic Card , Mfd Printer - Lsu Unit , Mfd Printer - Megnet , Mfd Printer - Motor , Mfd Printer - Paper Tray , Mfd Printer - Pick Roller , Mfd Printer - Pressor Roller , Mfd Printer - Repairing & Service Charhes , Mfd Printer - Scanner Unit , Mfd Printer - Sensor Unit , Mfd Printer - Sepration Paid , Mfd Printer - Smps , Mfd Printer - Teflon , Mfd Printer - Solenoid (Relay) , Ups - Invertor Card , Ups - Battery Charger (Heating Bridge) , Ups - Mospet , Ups - Resistance , Ups - Main Power Transformer , Ups - Capicitor , Ups - Inductor , Ups - Diode , Ups - Ic555 , Ups - Ic808 , Ups - Invertor Switch , Ups - Repairing & Service Charges Per Ups 500Va /650Va/ 750Va / 800Va/1000 Va , Ups - Battery - 7 Ah, 12 Volts, Smf , Head Name - Stationery Items , Printing Paper A4 (75 Gsm) , File Cover (Card Board Office File Cover, Paper Size: Fullscape) , File Pad (Cardboard Office File Pads) , All Pin Stanless Steel , Whitener Correction Pen 4 Inch , Pencil Black 6 Inch , Stapler Pin No 10 1M , Stapler Pin No 24/6 1M , Stapler N10 , Size: 4 Inch , Stapler Hp 45, Size: 7 X 3 X 17.5 Centimeters , Stapler Heavy Duty ,Stapling Capacity: 210 Sheets , Stapler Pin 23/10-H , Note Sheet Paper A4 Size , U Shape Paper Pin/Gems Clip , Stamp Pad Blue For Stamping Purpose Size 110Mmx70mm , Stamp Pad Blue For Stamping Purpose Size9.5 Cm X 5 Cm , Envelope White Paper For Letter, Courier And Documents, 90 Gsm, Size - 9 X 4 Inches , Envelope Yellow Inside Laminated11x5 Inch , White Board Marker Pen , Highlighter Pen For Marks Highlight Text-Line , Notes Paper Flags Re-Stick (25Mm X 75Mm) - 4 Colours , Magnetic Pin Cushion 7X4(Hxl)Mm , Stock Book With Amount Column - Hard Bound - Register Size - 32 X 20 Cm (90 Pages - Pack Of 1) , Gum Bottle 300Ml , Gum Bottle 700Ml , File Tag Thread Green 20 X 18 X 1 Centimeters (100 No) , File Tag Thread For Paper Binding - 6 Inch, White (100 No) , Dak-Pad (F/S Or Legal Size: 14.5 X 10 Inch) , Invert/Dispatch Register Etc. (Dispatch - 72Gsm 275 Pages) , Single Line Long Register (100 Pages) , Register 6Qr 16X26 Cm 400 Pages , Register 4Qr 16X26 Cm 200 Pages , Register 8Qr , 80 Gsm , Rubber Eraser For Pencil (Pack Of 10) , Bill Register 65 Gsm Green Ledger Paper, - Dimensions: 19.5 X 32.5 Cm( 4 Qr) , Shorthand Copy 100 Pages , Poker(Tocha) Plastic Handle 8 Inch , Steel Scale 12 Inch , Plastic Scale 12 Inch , Gel Pen 0.55Mm 10Pen Box Pack , Motor Vehicle Log Book - Hard Bound - 20 X 16 Cm , Self Adhesive Transparent Tapes 2.5Inchx65meters , Cello Tape 1 Inch 65M (Transparent) , Self Adhesive Brown Cello Tape - 100 Meters In Length - 48Mm / 2 Width , Glass Paper Weight 51D X 40W X 51H Millimeters , White Correction Fluid 15Ml , Daily Attendance Register, 75 Pages , Desk Table Plastic 15 X 21 Inch Top With Foldable Transparent, Adjustable 7Mm Writing Desk Stand, Z-Type , Desktop Calculator 150 Steps Check And Correct With Tax & Gt Keys & On Display Indication Of Active Constant , Glue Stick 25Gm , Ball Pen 0.7 Mm , Plastic L Folder, Clear Transparent Size Legal, F/S, ( Set Of 10 Pcs ) , Multicolor Plastic Envelope File Folder 13 Inch X 11 Inch , Leather, Foam Convocation File Folder, A4 , Register 3Qr , Register 2Qr , Executive Diary (75 Gsm Dual Color), B5 Size, Dated Diary , Pen Stand Compartments Wooden With Visiting Card & Mobile Holder For Office Table (Min Size 175 Mm, 75 Mm, 100 Mm) , Contingent Register-200 Folio , Paper Cutter 9Mm , Metal Binder Clip Double Clip Size 51 Mm , Pencil Sharpener Steel Blade , Cash Book As Mptc 5, A3 Size, 100 Pages, Min 80 Gsm Paper , Single Line 5 Subject Spiral Notebook (14 X 21.6 Cm) 70 Gsm , Envelope Laminated Yellow Paper Legal Size | Poly Laminated Inside | 10 X 14 Inch , Envelope Laminated Yellow Paper A3 Size | Poly Laminated Inside | 10 X 14 Inch , A4 Size Envelop Laminated Yellow10 X 12 Inch , Letter Head 125 Gsm, White , Colour Flag 3 X 3 , Visiting Card , Cartridge Sheet (140Gsm) , Sketch Pen 12Shade Multi Colour , Jute Folder (A4 Size) , Leather Multipurpose File Folder (A4 Size) , Jute Office Bag ( 38L X 10W X 30H Cms ) , Bond Paper A4 (100 Gsm) , Colour Copy & Printing Paper A4 (100 Gsm) , Excellence White Printing Paper A4 (100 Gsm) , Paper Sheets A4 (140 Gsm) , Punching Machine 1 Hole, Punching Capacity : Minimum 60 Sheets , Punching Machine 2 Holes, Punching Capacity : Minimum 20 Sheets , Punching Machine 2 Holes, Punching Capacity : Minimum 60 Sheets , Poker (Tocha) Metal Handle 8 Inch , Scissors Steel 5 Inches , Scissors Steel 9 Inches , Head Name - General Items , Milk Powder For Tea 500 Gram Pack , Packaged Drinking Water 200 Ml , Packaged Drinking Water 500 Ml , Packaged Drinking Water 1 Ltr. , Green Tea - Detox/Desi Kahwa, 25 G (10 Bags X 2.5 G Each) , Honey Lemon Green Tea Bags, 35 G (25 Bags X 1.4 G Each) , Biscuit Butter/Cashew/ 50G Pack , Biscuit Tastier Sweet-Salty Crackers 75G Pack , Biscuits High Fibre 100G Pack , Sugar Cube, 500 G Pack , Sugar , Tea Premium With Long Leaves 500G , Coffee Pouch, 1Pcs Instant Coffee(60 X 1.67 G) , Samosha/Kachori , Khaman Dhokla 2 Pcs. , Chips 100 Gram , Mithai 500 Gram , Buttermilk (Matha/Chach) 250 Ml. , Namkeen 50 Gram , Lunch Or Dinner Thali ( Daal, Rice, Paneer Sabzi, Seasonal Veg, Curd Item, 5 Tawa Rotis, 1 Pcs. Sweet & Salad ) , Tea Cup Bone China White Color Gold Design 160 Ml , White Tea Cup Set Of 6, , Plate Bone Ash Free Quarter Plate 7.5(6 Pcs) , Serving Tray Platter Rectangular Plastic Tray 35L X 25W X 4H Centimeters , Electric Kettle 1.8L, Stainless Steel Inner Body - Auto Power Cut, Boil Dry Protection & Cool Touch Double Wall, Portable | 1500 Watts, Size- 24L X 20W X 28H Centimeters , Electric Kettle, Stainless Steel Quick Boil, 1 Ltr, 7.9L X 6.3W X 7.9H Centimeters , Transparent Water Glass Set Of 6 Pcs (300 Ml Each) Large Flame Proof Round Shape Glasses , Spoon Stainless Steel Set Length 16.6Cm (Medium, Set Of 12) , Tissue Paper 30X27 Cm (100 Sheets Per Pack) , Facial Tissue 2 Ply Soft Pack - 200 Pulls , Dishwash Bar, 125G , Air Freshener 48 G (Pack) , Room Freshener Spray (220 Ml) , Detergent Bar, 110 G , Mosquito Vaporiser Refill + Machine - 45Ml , Liquid Vaporiser Mosquito Repellent Refill 45 Ml , Tea Strainer Chai Chalni Stainless Steel , Thermos, Thermo Steel Vacuum Insulated 24 Hours Hot Or Cold Carafe, 1000 Ml , Handwash Refill - Skincare Hand Wash- 1500Ml Pack , Dishwash Liquid , 250 Ml Bottle , Men Raincoat Free Size , Umbrella- 54 Inch Heavy Duty , Pre Ink Stamp Small 1.2Cmx3.6Cm , Pre Ink Stamp Size 2.1Cmx5.7Cm , Cell Carbon Zinc Aa Battery - 10 Pieces , Cell Aaa Batteries - Pack Of 10 , Nameplate Fiber 6 X 12 , Double Side Name Plate , Name Plate Big Size 10 X 12 , Door Bell (Wireless) , Door Locks (Tala) , Plastic Open Dustbin, (8 L) , Plastic Pedal Dustbin , 10 L , 9 Watt Led , 12 Watt Led , Tube Light Led (15 Watt) , Electric Cable(3Colour) , Cooler Pad, Khus (4 Feet) , 3 Pintop (5A) , 3 Pintop(15A) , Gi Wire (1Kg) , Modular Socket (5Amp) , Socket Modular (5Amp) , Extension Board - 5 Power Sockets, 15 Amps 2Mtr , Extension Board - 5 Power Sockets, 15 Amps 3Mtr , Extension Board - 5 Power Sockets, 15 Amps 5Mtr , Wire 3 Cable Core , Office - Identity Card Pvc (Standard Size) With Card Holder & Strap , Round White Disposable Paper Plates Size : 6 Inches (Pack Of 50 Plates) , Disposable Wooden Spoons Length : 14 Cm. (Pack Of 100 Pcs.) , Head Name - Printer Cartridge (Original) , Toner Cartridge Canon 303 , Toner Cartridge H.P. 12A , Toner Cartridge H.P. 53A , Toner Cartridge H.P. 36A , Toner Cartridge H.P. 16A , Toner Cartridge Samsung108/104 , Toner Cartridge Samsung 1640 , Toner Cartridge Samsung 4720/1610 , Toner Cartridge Samsung 209 , Toner Cartridge Samsung 2161 , Toner Cartridge Samsung Scx 4521 Fs , Toner Canon Mf 248Dw , Toner Canon Mf 271 Dn , Hp Laser Jet M1212 Nf Mfd , Toner Canon 051 , Toner H P 77A , Toner H P 88-A , Toner Samsung 1043 , Toner Samsung 205 , Toner Canon 328 , Toner Canon 925 , Toner Cartridge Canon 326 , Toner Cartridge Samsung 101 , Toner Cartridge Samsung 116 , Toner Cartridge Canon 337 , Toner Cartridge Hp Lajer Mfp-136A , Toner Cartridge H.P. 110A , Toner Cartridge H.P. Mfd - 2606Dn , Toner Cartridge Brother- B-700D , Toner Cartridge H.P. Tower- 136A , Toner Cartridge - Canon - Image Class -Mf284dw - Cartridge- 072 , Toner Cartridge - Canon - Image Class -Mf271dn - Cartridge- 071 , Toner Cartridge - Canon - Image Class -Mf289dw , Toner Cartridge - Canon - Image Class -Mf643cdw - Cartridge- 054 (Kycm - Each) , Canon Ir 222N-Nb59 , Hp- Laser Jet -Mfp M-233Sdw , Samsung Mlt B48c602160 , Samsung Ml2161 , Samsung Ml 1640 , Samsung Scx 4521 Fs , Canon Mf 248 Dw , Canon Mf271dn , Canon Lbp 122 D , Canon Vrf 273 , Canon Mf 4820D , Canon Mf 240 4F Riit , Canon Image Class Mf 4820 D , Canon Lbp 6018 B , Canon Ic Mf 4820 D , Canon Ic 271 Dn , Canon Ic 241 Dw , Canon Image Runner 224 N , Canon Ic Lbd 122 Dw , Canon Mf 240 Series , Canon 643C Dw , Toner Cartridge 3060 , Image Class Mf 2410 , Image Class Mf 24 1 Dw , Image Class Mf-284Dw , Brother Dcp B7500d , H.P. Laser Jet Mfp M 4360N , H.P. Laser Jet Mfp 136 A , H.P. Laser Jet Tank Mfp 2606 Oix , H.P. Laser Jet M 1213 Mfd , H.P. Mf486 Dw , H.P. Toner Cartridge 158 , Toner Cartridge Brother 3060 , Toner Cartridge Hp -Mfp 436 Dn , Toner Cartridge Brother -B021 , Head Name - Photo Copy , Photo Copy On A4 Size Paper (With Min 75 Gsm Paper) , Photo Copy On A3 Size Paper (With Min 75 Gsm Paper) , Colour Printing Work On A4 Size Paper , Spiral Binding With Binding Covers A4 Size , Head Name - Rented Vehicle , Monthly Charge Of Vehicle For Maximum 800 Km (Sedan Car Of Max. Rs. 7.00 Lakh Ex Showroom Price) , Variable Charge For Journey Outside Headquarter Or Within Headquarters Beyond Maximum Limit , Head Name - Rented Cooler , Monthly Charge Of Air Cooler, Tank Capacity: 40 Ltr., Isi Marked , Monthly Charge Of Air Cooler, Tank Capacity: 75 Ltr., Isi Marked
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Madhya Pradesh View Result →
3.
Educational and Research Institute #11307517 Technical Bid
Tender For Ambedkar Gramam Project For Sc Unnathy Pookkunnimala- 1 1) Anganwadi-Civil Works-Ground Floor 2 15.9.2 Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 3 15.7.4 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 4 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 5 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 6 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 7 15.13.1 Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood ) Including Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 8 2.6.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge.All Kinds Of Soil 9 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) 10 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete 11 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 12 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 13 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 14 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 15 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 16 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 17 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 18 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. 19 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 20 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 21 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 22 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 23 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Bepaid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 24 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 25 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 26 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 27 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 28 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 29 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 30 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 31 Od123879/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 4 Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 32 Od123885/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 33 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 34 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 35 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 36 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 37 11.16.1 Precast Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Upto 12Mm, Laid In Floors, And Landings, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles Including Rubbing And Polishing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) :Light Shade Pigment Using White Cement 38 8.2.2.2 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror, Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Area Of Slab Over 0.50 Sqm 39 8.3.2 Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer -In-Charge.Granite Work 40 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 41 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 42 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 43 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 44 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 45 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 46 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 47 Od134882/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 48 Od134893/2025-2026 Providing And Fixing Anganwadi/Library/Vignjaanwadi -Foundation Stone/Inauguration Stone Using Granite Of Size 70.00X135.00 Cm ,18Mm Thick With Writing Letters In Golden Colour Including Of All Material And Labour Charges Etc. Complete As Per The Directions Of Engineer-In-Charge. 49 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil 50 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. 51 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 52 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 53 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+0.05%), Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 54 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm) 55 Od141946/2025-2026 Providing And Fixing 8 Upvc Aqua Pathy ( Gutter) With M.S Clamp All Complete As Per Direction Of Engineer-In-Charge. 56 1)Vignjaanwadi,Library Cum Reading Room-First Floor 57 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts 58 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers 59 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 60 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform 61 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). 62 5.22.6 Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 63 50.6.1.2 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X20Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement: 6 Coarse Sand) Etc Complete. 64 13.7.1 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) 65 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 66 13.4.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Coarse Sand) 67 50.9.1.1 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood 68 50.9.2.1 Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 9 Paid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood 69 50.9.6.1 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4 Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Using Anjili Wood / Jack Wood 30 Mm Thick Shutters 70 14.29 Providing And Fixing M.S. Round Or Squre Bars With M.S. Flats At Required Spacing In Wooden Frames Of Windows And Clerestory Windows. 71 10.27.5 Providing And Fixing Carbon Steel Galvanised ( Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480 N/Mm2), Counter Sunk Head, Comprising Of 10 M Dia Polyamide P A 6 Grade Sleeve, Including Drilling Of Hole In Frame, Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge.10X 160 Mm 72 9.76 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 73 9.92.1 Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 74 9.74.3 Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Necessary Screws Etc. Complete:150X10 Mm 75 9.83 Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 76 Od127305/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 80Cm 28-30Mm Thickness With Frame And Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 77 Od126510/2025-2026 Providing And Fixing Frp (Fibre Reinforced Polymer) Door Shutter Of Size 90Cm And 28-30Mm Thickness With Frame 110Mm Thickness With Necessary Fittings Like Hinges, Tower Bolts, Handles, Mortice/Cylindrical Locks And All Other Accessories Etc. Complete Including All Materials And Labour Charge Etc As Per The Direction Of Engineer In Charge 78 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 79 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm 80 11.37 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete 81 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 82 13.80 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 83 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 84 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 85 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 86 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 87 13.61.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 88 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) 89 Od135395/2025-2026 Supplying And Fixing Anganwadi/Library/Vignjaanwadi Name Board With Emblem Using Acrylic Sheet Base With Reflective Type Sticker As Per Required Shade And Color Etc Complete. Size Of Board 3.00Mx 0.60M 90 1)Plumbing Works -Ground Floor & First Floor 91 17.3.2 Providing And Fixing White Vitreous China Pedestal Type Water Closet Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 92 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 93 17.7.2 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 94 17.9.1 Providing And Fixing Kitchen Sink With C. I Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm 95 18.53.1 Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 96 18.32.1 Constructing Masonry Chamber 30X30X50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Stop Cock, With C.I. Surface Box 100X100X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S (Non Modular) Bricks Of Class Designation 7.5 97 17.73.2 Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighting Not Less Than 190 Gms 98 18.51.1 Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15 Mm Nominal Bore 99 50.18.7.2.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Claps At 1.00 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 20 Mm Dia 12Kgf/Cm2 - Internal Work - Exposed On Wall 100 50.18.9.3.2 Providing And Fixing Pvc Pipes Includes Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 25 Mm Dia 10Kgf/Cm2 101 50.18.7.6.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 10 Kfg/Cm - Internal Work- Exposed On Wall 102 50.18.9.7.1 Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 6Kgf/Cm3 103 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 104 50.18.9.22.1 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 105 50.18.9.22.2 Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia 45 Degree Elbow 106 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend 107 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110X110 Mm Dia Tee 108 50.18.9.22.7 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110X110X75 Mm Dia Door Tee 109 18.58.2.1 Providing And Fixing Ptmt Grating Of Approved Quality And Colour. Rectangular Type With Openable Circular Lid150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating 110 51.19.St4 Supplying And Installing Ready Made Pvc Septic Tank Including The Cost Of Carriage, Trenching, Placing At The Level Below Ground Level As Specified As Per The Direction Of Engineer In Charge (Provision For Cc/Rcc/Sand/06Mm Aggregate For The Preparation Of Bed Shall Be Paid Separately) 4. 35 To 50 Flush Capacity 111 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 112 Od141980/2025-2026 Providing 25Mm/32Mm (3/4 Inch/1 Inch) Public Building Connection With 20Mm (3/4 Inch) Water Meter From Existing Ci Mains Up To 125 Mm Dia., Up To A Length Of 5 M Using 25Mm Indian Standard Class 6 Upvc Pipe And Upvc / Gm / Brass Specials Viz. Brass Ferrule, Gm Full Way Wheel Valve, Elbow, Mta, Fta, Couplers Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges , Cost Of Water Meter And Meter Box, Deposit Charges Of Kwa And Including Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, If Necessary And As Per The Direction Of The Engineer-In-Charge. 113 1)Electrical Works -Ground Floor & First Floor 114 1.10.3 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C 115 1.14.2 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 116 1.23.4 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required.3 Pin 5/6 Amp Socket Outlet 117 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Amp Switch 118 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Amp Socket Outlet 119 1.12 Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 120 2.3.3 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way, Double Door 121 1.25 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 122 5.4 Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. 123 5.19 Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. 124 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75Mm) 125 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps 126 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 127 1.14.1 Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2X1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 128 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Od123876/2025-2026 Supplying And Fixing Following 32 Amps Modular Dp Switch And Other Accessories Etc Complete 130 Od123878/2025-2026 Supplying And Fixing 14 W Led Connect With Bulk Head Fixing And Other Accessories 131 Od123874/2025-2026 Supply And Fixing Angle Batten With 7/9 Watts Led And Other Accessories 132 Od123877/2025-2026 Supply And Fixing Angle Batten With 14/15 Watts Led And Other Accessories 133 Od123872/2025-2026 Supplying And Fixing 20W Led Tube Set (Approved Brands) And Other Accessories 134 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply 135 Od123875/2025-2026 Supplying, Installing, Testing And Commissioning Of Wall Mounted Single Phase 2 Wire Energy Meter With Meter Box Poly Carbonate Body Having Range Of 32 Amp With Enclosure Made Out Of Powder Coated 16 Swg Sheet Suitable For Fixing In Surface/ Recess With Fuse Unit 32 Amp With Neutral Link, Its Interconnection Etc. The Enclosure Shall Have Lockable Door With Glass Window And All Mounting Accessories Etc. Complete As Required Including Kseb Charges 136 2)Childrens Play Equipments 137 Od135736/2025-2026 Supply And Fixing ChildrenS Play Equipment Circular See-Saw Including Cost Of All Materials And Labour Charges Etc Complete. 138 Od135738/2025-2026 Supplying And Fixing ChildrenS Play Equipment Step With Slide Including Cost Of All Materials And Labour Charges, Etc. 139 3)Community Hall-Renovation-Civil Works 140 15.28.1 Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 141 15.19 Dismantling Steel Work Manually / By Mechanical Means In Built Up Sections Without Dismembering And Stacking Within 50 Metres Lead As Per Directions Of Engineer -In- Charge. 142 15.2.2 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) 143 13.33.1 Pointing On Stone Work With Cement Mortar 1:3 ( 1 Cement : 3 Fine Sand):Flush/ Ruled Pointing 144 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 145 11.41.2 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. 146 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 147 13.91 Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete 148 13.43.1 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer 149 13.60.1 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 150 13.47.1 Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade:New Work (Two Or More Coats Applied @ 1.43 Ltr/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/ 10 Sqm) 151 13.88 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 152 13.85.1 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre 153 13.99.1 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 154 50.10.1 Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 155 50.10.2 Steel Work For Purlin/Single Section With G I Pipes Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete 156 12.50 Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Cost Index (Place) : Kollam, Gst : 18% Printed On 2026-03-17 13:56:12.13 20 Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling/Self Tapping Screws Of Size (5.5X55Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 157 12.51.1 Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screwscomplete :Ridges Plain (500-600 Mm)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
4.
Housing Urban and Rular Development #11306856 AOC
Tender For M.O.W. Work (Additional Room) In Bunglow No. Eg-9/3 And Ek-9/3 Under Section No.1 Survey Sub Dn. Bhopal- 1 M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal 1st Call P.A.C. 29.64 Lakh,as per Building SOR wef 01-01-2024 Schedule Attached Complition period 90 Days Please Enable Macros to View BoQ information SCHEDULE OF ITEMS Name of work : M.O.W. Work (Additional Room) in Bunglow No. EG-9/3 and EK-9/3 Under Section No.1 Survey Sub Dn. Bhopal Probable Amount of contract : Rs. 29.64 Lacs. (Rs. in Figures) : Time Alloved : 6 months i/c rainy season S.No SOR Item Particulers of Item Unit Rate Remarks 2 2.4 2.4.1 beyond 30 cm girth up to and including 60 cm girth each 350.0 2.4.2 beyond 60 cm girth up to and including 120 cm girth each 1150.0 2.4.3 beyond 120 cm girth up to and including 240 cm girth each 3500.0 2.4.4 above 240 cm girth each 6300.0 3 2.7 2.7.1 Ordinary rock cum 287.0 2.7.2 Hard rock (requiring blasting) cum 519.0 2.7.3 Hard rock (blasting prohibited) cum 828.0 4 2.25 2.25.1 All kinds of soil. cum 30.0 2.25.2 Ordinary or hard rock. cum 53.0 2.26 Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding 20cm in depth and dressing complete cum 672.0 Note: - Maximum thickness of this layer shall be 20 cm. 5 2.27 2.27.1 With hard muram having CBR >12 % at under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 20cm in thickness and dressing complete. (Note:- maximum thickness of this layer to be provided shall be 30cm) cum 393.0 2.27.2 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm cum 331.0 6 2.28 2.28.1 All kinds of soil. each 42.0 2.28.2 Ordinary rock each 68.0 2.28.3 Hard rock (requiring blasting) each 138.0 2.28.4 Hard rock (blasting prohibited) each 151.0 7 2.3 2.30.1 Along external wall where the apron is not provided using chemical emulsion@ 7.5 liters / sqm of the vertical surfaceof the substructure to a depth of 300mm including excavation channel along the wall and rodding etc. complete, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 36.0 2.30.2 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 42.0 2.30.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. sqm 199.0 2.30.4 Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling 10mm dia and 200mm deep holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. metre 50.0 2.30.5 Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litresper hole by drilling 6 mm dia holes at downward angle of 45 degree at 150mm centre to centre and sealing the same. metre 201.0 8 2.41 2.42.1 Supplying and filing in plinth with soil (other then BC soil ) having MDD not less than 1.85 t/m3 under floors including watering, ramming and compacting (minimum compaction 95% of MDD) in layers not exceeding 15cm depth and dressing complete. cum 331.0 9 4.1 4.1.1 With 20mm nominal size graded stone aggregate. 4.1.1.1 M-25 – Grade concrete cum 6338.0 4.1.1.2 M-20 – Grade concrete cum 4933.0 4.1.1.3 M-15 – Grade concrete cum 4471.0 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) cum 3890.0 4.1.2 With 40mm nominal size graded stone aggregate. 4.1.2.1 M-15 - Grade concrete cum 4403.0 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 sand : 6 graded stone aggregate) cum 3808.0 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 sand : 8 graded stone aggregate cum 3474.0 4.1.3 With fly ash. Note: No fly ash is to be added to Portland Pozzolona cement in any case which itself contains fly ash. 10 4.2 string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. upto floor two level, excluding the cost of centering, shuttering and finishing : 4.2.1 With 20mm nominal size graded stone aggregate 4.2.1.1 M-25 – Grade concrete Cum 6582.0 4.2.1.2 M 20 – Grade concrete Cum 5177.0 4.2.1.3 M 15 – Grade concrete Cum 4714.0 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate Cum 4134.0 4.2.2 With 40mm nominal size graded stone aggregate 4.2.2.1 M-15 - Grade concrete cum 4647.0 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate cum 4052.0 11 4.3 4.3.1 Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. Sqm 169.0 4.3.2 above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, and string courses fillets etc. sqm 267.0 4.3.3 Above plinth: Columns, pillars, posts and struts. Sqm 356.0 12 4.6 4.6.1 M-25 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.2 M-20 (With 20mm nominal size graded stone aggregate) cum 5558.0 4.6.3 M-15 (With 20mm nominal size graded stone aggregate) cum 5095.0 4.6.4 M-10 (With 20mm nominal size graded stone aggregate) Nominal Mix -1 Cement: 3 sand: 6 graded stone aggregate. cum 4515.0 4.1 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 12.5mm nominal size). Sqm 200.0 13 5.1 5.1.1 M-20 Grade Concrete cum 6153.0 5.1.2 M-15 Grade Concrete cum 5397.0 14 5.2 5.2.1 M-20 Grade Concrete cum 6231.0 15 5.3 5.3.1 M-20 Grade Concrete cum 6541.0 16 5.4 5.4.1 M-20 Grade Concrete cum 5542.0 17 5.5 5.5.1 M-20 Grade Concrete cum 6906.0 18 5.6.1 5.6.1 M-20 Grade Concrete cum 6337.0 19 5.7.1 5.7.1 M-20 Grade Concrete cum 5448.0 20 5.9.1 5.9.1 Foundations, footings, bases of columns, etc. for concrete upto plinth level sqm 190.6 5.9.2 Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. 5.9.2.1 Uptoplinthlevel. sqm 219.0 5.9.2.2 Above plinth upto 3.6 m height from plinth level sqm 330.0 5.9.2.3 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.6 m, for every additional height of 1 metre or part thereof. sqm 40.0 5.9.3 Suspended floors, roofs, landings, balconies and access platform. sqm 439.6 5.9.4 Shelves(Cast in situ) sqm 290.0 5.9.5 Lintels, beams, girders, bressumers and cantilevers sqm 356.0 5.9.6 Columns, P i l l a r s , Piers, Abutments, sqm 471.2 Posts and Struts. 5.9.7 Stairs, (excluding landings) except spiral- Staircases. sqm 435.7 5.9.8 Spiral staircases (including landing). sqm 450.0 5.9.9 Arches, domes,vaults upto 6m span sqm 1141.6 5.9.10 Extra for arches, domes, vaults exceeding 6 m span sqm 451.3 5.9.11 Chimneys and shafts sqm 294.0 5.9.12 Coffer/waffle slab of any size or shape as shown in the drawing. sqm 1481.0 5.9.15 Extra for shuttering in circular work or any other geometrical shape (20% of respective centering and shuttering items). sqm 0.2 5.9.16 Small lintels not exceeding 1.5m clear span, mouldingas incornices, window, sills, courses, bands, copings, bed plates, anchor blocks and the like. sqm 191.0 5.9.17 Cornices and mouldings sqm 565.0 5.9.18 Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. sqm 529.6 5.9.19 Weather shade, Chajjas, corbels etc., including Edges. sqm 534.2 5.9.20 Suspended floors, roofs, landings, balconies and Access platform. With water proof ply 12 mm thick. (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 575.35 5.9.21 Lintels, beams, columns, girders, bressumers and cantilevers with waterproof ply 12 mm thick (item to be executed with prior permission of C.E./S.E. in case of B & R works . sqm 521.2 21 5.1 5.10.1 Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). sqm 212.0 22 5.12 5.12.1 50 mm thick sqm 790.0 5.12.2 40 mm thick sqm 689.0 5.12.3 25 mm thick sqm 598.0 23 5.16 5.16.1 Mild steel and Medium Tensile steel bars. kg 78 .00 5.16.2 Hard drawn steel wire kg 75.0 5.16.3 Cold twisted bars (CTD) kg 81.0 5.16.4 Hot rolled deformed bars kg 81.0 5.16.5 Hard drawn steel wire fabric kg 76.0 5.16.6 Thermo-Mechanically Treated bars.FE 500 D or more conforming to IS 1786 kg 80.0 5.16.7 Thermo-Mechanically Treated bars. FE 500 conforming .to IS 1786 kg 77.0 5.16.8 Corrosion resistance Steel bar Grade Fe-500 D & above , use with prior permission of C.E. Kg 98.0 24 5.22 5. 22.1 12 mm thick sqm 402.0 5. 22.2 25 mm thick sqm 574.0 5. 22.3 50 mm thick sqm 674.0 5.23 Providing and fixing sheet covering over expansion joints with iron screws as per design. 5. 23.1 Non-asbestos fibre cement board 6 mm thick as per IS: 14862. 5. 23.1.1 150mm wide. RM 102.0 5. 23.1.2 200mm wide. RM 137.0 5. 23.1.3 250mm wide. RM 153.0 5. 23.2 Aluminium fluted strips 3.15mm thick. 5. 23.2.1 150 mm wide. RM 483.0 5. 23.2.2 200 mm wide. RM 646.0 5. 23.2.3 250 mm wide. RM 725.0 5. 23.3 Stainless steel Grade 304 plate-1.0 mm thick 5. 23.3.1 150 mm wide. RM 367.0 5. 23.3.2 200 mm wide. RM 443.0 5. 23.3.3 250 mm wide. RM 555.0 25 5.24 5.24.1 Preparation of grooves RM 18.5 5.24.2 Preparation of Drip course RM 30.0 26 5.32 5.32.1 Non pigmented wet curing compound sqm 93.0 5.32.2 Pigmented wet curing compound. sqm 100.0 27 6.1 6.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5818.0 6.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5626.0 28 6.2 6.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 6012.0 6.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5821.0 6.3 Brick work with well burnt chimney bricks in bulls pattern trench kiln manufactured by ghol process, crushing strength not lessthan 40kg /cm2 and water absorptionnot more than 15% in foundation and plinth i/c curing etc. complete. 6.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5252.0 6.3.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5061.0 29 6.4 6.4.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5446.0 6.4.2 Cement Mortar 1:6 (1 cement:6 sand). cum 5255.0 30 6.5 6.5.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4347.0 6.5.2 Cement Mortar 1:6 (1 cement: 6 sand). cum 4155.0 31 6.6 6.6.1 Cement mortar 1:4 (1 cement : 4 sand) cum 4541.0 6.6.2 Cement Mortar 1:6 (1 cement : 6 sand) cum 4350.0 32 6.7 6.7.1 Having 100 kg / cm2 average compressive strength. 6.7.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5384.0 6.7.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5162.0 6.7.2 Having 75 kg / cm2 average compressive strength. 6.7.2.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5271.0 6.7.2.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5049.0 6.7.3 Having 50 kg / cm2 average compressive strength. 6.7.3.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5158.0 6.7.3.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4936.0 33 6.8 6.8.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5287.0 6.8.2 Cement mortar 1:6 (1 cement : 6 sand) cum 5095.0 34 6.9 Cement Mortar 1:4 ( 1 cement : 4 sand) 35 6.12 6.12.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 697.0 6.12.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 673.0 36 6.13 6.13.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 639.0 6.13.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 615.0 37 6.14 6.14.1 Cement mortar 1:3 (1 cement : 3 sand) sqm 546.0 6.14.2 Cement mortar 1:4 (1 cement : 4 sand) sqm 522.0 38 6.15 6.15.1 Having 100 kg/cm2 average compressive strength. 6.15.1.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 570.0 6.15.1.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 551.0 6.15.2 Having 75 kg/cm2 average compressive strength. 6.15.2.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 524.0 6.15.2.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 505.0 6.15.3 Having 50 kg/cm2 average compressive strength. 6.15.3.1 Cement mortar 1 : 3 (1 cement : 3 sand) sqm 479.0 6.15.3.2 Cement mortar 1 : 4 (1 cement : 4 sand) sqm 459.0 39 6.37 6.37.1 Having100 kg / cm2 average compressive strength. 6.37.1.1 Cement mortar 1:4 (1 cement : 4 sand) cum 5115.0 6.37.1.2 Cement mortar 1:6 (1 cement : 6 sand) cum 4904.0 6.37.2 Having75 kg / cm2 average compressive strength. 6.37.2.1 Cement mortar 1:4 (1 cement : 4sand) cum 5007.0 6.37.2.2 Cement mortar 1:6 (1 cement : 6sand) cum 4797.0 6.37.3 Having50 kg / cm2 averagecompressive strength. 6.37.3.1 Cement mortar 1:4 (1 cement : 4sand) cum 4900.0 6.37.3.2 Cement mortar 1:6 (1 cement : 6sand) cum 4689.0 40 9.3 9.3.1 Sal wood cum 76229.0 9.3.2 Kiln seasoned and chemically treated hardwood Haldu, Kail, Bija wood. cum 77538.0 9.3.3 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 64833.0 41 9.4 9.4.1 Second class teak wood cum 9062.0 9.4.2 Sal wood cum 7131.0 9.4.3 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. cum 7275.0 9.4.4 Factory made Kiln seasoned, chemically treated, finger jointed at spacing not closer than 50 cm, 2nd class hard wood. cum 6030.0 9.5.4.1 35 mm thick sqm 1089.0 9.5.4.2 30 mm thick sqm 969.0 42 9.6 9.6.1 Second class teak wood sqm 2215.0 9.6.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood sqm 1763.0 9.6.3 15mm thick Factory made Kiln seasoned, chemically treated and finger jointed at spacing not closer than 50cm, 2nd class hard wood. sqm 971.0 9.6.4 Ply wood 5 ply, 9 mm thick : 9.6.4.1 Decorative plywood both side decorative veneer (Type - I) conforming to IS 1328 BWR type. sqm 1439.0 9.6.4.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type sqm 1369.0 9.6.5 Ply wood 7 ply, 9 mm thick : 9.6.5.1 Decorative plywood both side decorative veneer (Type- I) conforming to IS 1328 BWR type. sqm 1861.0 9.6.5.2 Decorative plywood one side decorative veneer and commercial veneer on other face (Type-1) conforming to IS 1328 BWR Type sqm 1650.0 9.6.6 Particle Board 12 mm thick 9.6.6.1 Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked. sqm 791.0 9.6.6.2 Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS: 3097, grade I. sqm 1087.0 9.6.6.3 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked. sqm 1333.0 9.6.6.4 Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS: 12823 marked. sqm 1390.0 9.6.6.5 Coir Veneer Board (conforming to IS 14842) 12 mm thick sqm 1298.0 9.6.7 Float glass panes 9.6.7.1 4 mm thick glass pane (weight not less than 10 kg/sqm) sqm 973.0 9.6.7.2 5 mm thick glass pane (weight not less than 12.5 kg/sqm) sqm 1046.0 9.6.8 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. Wire and 1.4 mm wide aperture with matching wood beading sqm 1532.0 9.6.8.1 4mm to 5mm thick integral PVC form sheet with Celluka finish surface on both side with density not less than 600 kg/cum sqm 580.0 9.6.8.2 4mm to 5mm thick laminated PVC form sheet with density not less than 600 kg/cum, laminated on both sides by 0.12 mm thick laminated sheet with density not less than 1400 kg/cum sqm 754.0 43 9.14 9.14.1 Stainless steel butt hinges with stainless steel screws for 2nd class teak wood and other class of wood shutters. Sqm 170.0 9.14.2 ISI marked M.S. pressed butt hinges bright finished of required size For 2nd class teak wood and other class of wood shutters. Sqm 53.0 44 9.15 9.15.1 Panelled or panelled and glazed shutters : 9.15.1.1 Using ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2736.0 9.15.1.2 Using ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2753.0 9.15.2 Glazed shutters : 9.15.2.1 Second class teak wood including ISI marked anodised aluminium butt hinges with necessary screws. Sqm 2815.0 9.15.2.2 2nd class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 2759.0 45 9.16 9.16.1 12 mm thick Sqm 555.0 9.16.2 18 mm thick Sqm 654.0 46 9.17 9.17.1 18 mm thick Sqm 1270.0 9.17.2 25 mm thick Sqm 1383.0 47 9.18 9.18.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2823.0 9.18.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 2648.0 9.18.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS: 3818 marked with necessary screws. Sqm 2465.0 48 9.19 9.19.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1870.0 9.19.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Sqm 1696.0 9.19.3 25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws. Sqm 1623.0 49 9.2 9.21 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). Sqm 401.0 9.22 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : 9.22.1 Rectangular or square. Sqm 157.0 9.22.2 Circular. Sqm 244.0 50 9.25 9.25.1 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.1.1 Second class teak wood. Sqm 3174.0 9.25.1.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2599.0 9.25.1.3 Kiln seasoned selected class of sheesham wood. Sqm 2452.0 9.25.2 35 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.2.1 Second class teak wood. Sqm 3291.0 9.25.2.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2716.0 9.25.2.3 Kiln seasoned selected class of sheesham wood. Sqm 2569.0 9.25.3 30 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size. 9.25.3.1 Second class teak wood. Sqm 2797.0 9.25.3.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2306.0 9.25.3.3 Kiln seasoned selected class of sheesham wood. Sqm 2179.0 9.25.4 30 mm thick shutters with ISI marked stainless steel butt hinges of required size. 9.25.4.1 Second class teak wood. Sqm 2914.0 9.25.4.2 Kiln seasoned and chemically treated Haldu, Kail, Bija wood. Sqm 2423.0 9.25.4.3 Kiln seasoned selected class of sheesham wood. Sqm 2296.0 9.26.2 30 mm thick shutters Sqm 2102.0 51 9.57 9.57.1 300x16 mm Each 170.0 9.57.2 250x16 mm Each 157.0 52 9.58 9.58.1 250x10 mm Each 68.0 9.58.2 200x10 mm Each 60.0 9.58.3 150x10 mm Each 42.0 9.58.4 100x10 mm Each 35.0 53 9.6 9.60.1 300x20x6 mm Each 72.0 9.60.2 250x20x6 mm Each 67.0 54 9.61 9.61.1 125 mm Each 27.0 9.61.2 100 mm Each 25.0 9.61.3 75 mm Each 24.0 55 9.62 9.62.1 150 mm Each 23.0 9.62.2 115 mm Each 20.0 9.62.3 90 mm Each 17.0 56 9.63 9.63.1 300 mm weighing not less than 200 gms. Each 40.0 9.63.2 250 mm weighing not less than 150 gms. Each 34.0 9.63.3 200 mm weighing not less than 120 gms. Each 28.0 57 9.65 9.65.1 300x16 mm Each 389.0 9.65.2 250x16 mm Each 326.0 9.65.3 400x16mm Each 601.0 58 9.66 9.66.1 250x10 mm Each 148.0 9.66.2 200x10 mm Each 93.0 9.66.3 150x10 mm Each 71.0 9.66.4 100x10 mm Each 50.0 59 9.68 9.68.1 300x20x6 mm Each 211.0 9.68.2 250x20x6 mm Each 173.0 9.69 Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete : Each 9.69.1 125 mm Each 60.0 9.69.2 100 mm Each 54.0 9.69.3 75 mm Each 48.0 60 9.7 9.70.1 150 mm each 37.0 9.70.2 115 mm each 33.0 9.70.3 90 mm each 26.0 61 9.73 9.73.1 125x64x1.90 mm each 67.0 9.73.2 100X58X1.90 mm each 59.0 9.73.3 75x47x1.80 mm each 39.0 9.73.4 50x37x1.50 mm each 25.0 62 9.74 9.74.1 125x64x2.50 mm each 76.0 9.74.2 100x60x2.50 mm each 60.0 9.74.3 75x50x2.50 mm each 46.0 63 9.76 9.77 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 9.77.1 125x85x5.5 mm (heavy type) each 456.0 9.77.2 125x70x4 mm (ordinary type) each 148.0 9.77.3 100x85x5.5 mm (heavy type) each 387.0 9.77.4 100x70x4 mm (ordinary type) each 117.0 9.77.5 75x65x4 mm (heavy type) each 145.0 9.77.6 75x40x2.5 mm (ordinary type) each 74.0 9.77.7 50x40x2.5 mm (ordinary type) each 32.0 64 9.78 9.78.1 150x125x27x5 mm each 385.0 9.78.2 125x125x27x5 mm each 345.0 9.78.3 100x125x27x5 mm each 304.0 9.78.4 75x100x20x3.2 mm each 239.0 65 9.79 9.79.1 400x10 mm each 400.0 9.79.2 250x10 mm each 329.0 9.79.3 200x10 mm each 261.0 9.79.4 150x10 mm each 221.0 9.79.5 100x10 mm each 142.0 66 9.8 9.80.1 300x16x5 mm each 237.0 9.80.2 250x16x5 mm each 225.0 67 9.81 9.81.1 125 mm each 205.0 9.81.2 100 mm each 181.0 9.81.3 75 mm each 141.0 68 9.82 9.82.1 300x16mm each 407.0 9.82.2 250x16mm each 374.0 69 9.87 9.87.1 40 mm each 144.0 9.87.2 50 mm each 150.0 9.87.3 65 mm each 162.0 9.87.4 75 mm each 185.0 70 9.99 9.99.1 Size 40 mm each 144.0 9.99.2 Size 50 mm each 156.0 9.99.3 Size 65 mm each 167.0 9.99.4 Size 75 mm each 196.0 71 9.101 9.101.1 300x16mm each 268.0 9.101.2 250x16mm each 245.0 72 9.102 9.102.1 400X10mm each 260.0 9.102.2 300x10mm each 198.0 9.102.3 250x10mm each 164.0 9.102.4 200x10 mm each 113.0 9.102.5 150x10 mm each 91.0 9.102.6 100x10 mm each 73.0 73 9.103 9.103.1 300x16x5mm each 255.0 9.103.2 250x16x5mm each 243.0 74 9.108 9.108.1 125x75x4 mm each 115.0 9.108.2 125x63x4 mm each 108.0 9.108.3 100x75x4 mm each 95.0 9.108.4 100x63x4 mm each 93.0 9.108.5 100x63x3.2 mm each 90.0 9.108.6 75x63x4 mm each 77.0 9.108.7 75x63x3.2 mm each 75.0 9.108.8 75x45x3.2 mm each 67.0 75 9.109 9.109.1 300x16 mm each 241.0 9.109.2 250x16 mm each 195.0 76 9.11 9.110.1 400X10mm each 123.0 9.110.2 300x10 mm each 114.0 9.110.3 250x10 mm each 102.0 9.110.4 200x10 mm each 82.0 9.110.5 150x10 mm each 69.0 9.110.6 100x10 mm each 55.0 77 9.111 78 9.113 9.113.1 125 mm each 75.0 9.113.2 100 mm each 55.0 9.113.3 75 mm each 46.0 79 9.114 9.114.1 Single rubber stopper each 35.0 9.114.2 Twin rubber stopper each 86.0 80 9.116 81 9.117 82 9.126 83 9.127 84 9.128 85 9.129 9.129.1 Triple strip vertical type. each 28.0 9.129.2 Double strip (horizontal type). each 23.0 9.131 Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in-charge. 9.131.1 300mm long each set 209.0 9.131.2 450mm long each set 256.0 9.131.3 500mm long each set 302.0 86 9.132 87 9.133 9.133.1 Marine plywood conforming to IS: 710 sqm 1591.0 9.133.2 Fire retardant plywood conforming to IS: 5509. sqm 1660.0 88 9.134.1 9.134.1 1.5 mm thick. sqm 851.0 89 9.134.2 90 9.138 9.138.1 12 mm thick. sqm 919.0 9.138.2 18 mm thick. sqm 1161.0 9.138.3 25 mm thick. sqm 1230.0 91 9.139 92 9.14 9.140.1 18 mm thick sqm 1493.0 9.140.2 25 mm thick sqm 2017.0 93 9.145 9.145.1 Board 12 mm thick sqm 811.0 9.145.2 Board 18 mm thick sqm 943.0 9.146 Providing and fixing Pre-laminated medium density fibre board IS: 14587:1998 marked, with one side decorative lamination other side balancing lamination Grade-I(exterior grade) in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand (fittings to be paid separately). 9.146.1 18 mm thick sqm 1055.0 9.146.2 25 mm thick sqm 1420.0 94 9.147 95 9.148 96 9.15 9.150.1 12 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1210.0 9.150.2 18 mm thick commercial ply conforming to IS: 1328 BWR type. Sqm 1320.0 97 9.158 9.158.1 Extruded section Profile size 48x40 mm. metre 203.0 9.158.2 Extruded section Profile size 42x50 mm. metre 208.0 98 9.165 99 9.166 9.166.1 Plain PVC door shutters. sqm 2026.0 9.166.2 Pre laminated PVC door shutters. sqm 2490.0 100 9.167 101 9.168 as panel. The styles andrails will be mitred cut and joint with the help of PVC solvent cement and self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mmand 15 mm integrally extruded in the middle of the lock rail and fixed with styles with the help of PVC solvent cement and self driven self tapping screws of size 100 mmx8 mm complete as per manufacturers specifications and direction of Engineer-in-charge: 9.168.1 Non decorative finish. sqm 2026.0 9.168.2 Decorative finish (both side wood grained finish). sqm 2432.0 102 9.169 9.169.1 Single rebate (75 mm X 50 mm) RM 459.0 9.169.2 Single rebate (100 mm X50 mm) RM 720.0 9.169.3 Single or double rebate (125 mm X 65 mm) RM 923.0 103 9.17 9.170.1 24 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 2250.0 9.170.2 28 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3250.0 9.170.3 30 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 3693.0 9.170.4 35 mm thick WPC (Wood polymer composite) solid plain flush door shutter sqm 4135.0 104 9.186 105 9.187 9.187.1 Casement Window (Outward/Inward opening) with hinge System. 9.187.1.1 Frame (50 mm x 50mm) metre 422.0 9.187.1.2 Sash (Style and Rail) (62 mm x 34 mm) metre 403.0 9.187.1.3 Mullion (intermediate Section) (66mm x 50 mm) metre 434.0 9.187.1.4 ‘T Profile (one vertical length in between two shutters) (24mm x 34.5mm) metre 99.0 9.187.1.5 Glazing bead (12mm x 18mm) metre 130.0 9.187.2 Casement Window (With friction hinge and outward opening) 9.187.2.1 Casement Frame (67mm x 62mm) metre 495.0 9.187.2.2 Casement Window Sash/Mullion (67mm x75mm) (style, rail and intermediate section) metre 519.0 9.187.2.3 Casement Glazing bead (35mm x 18 mm) metre 178.0 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67mm x 52mm) metre 9.187.3.2 Sliding window Sash (60mm x 44mm) metre 529.0 9.187.3.3 Sliding Interlock for Window (one vertical length in each shutter)(45.5 mm x 28 mm) metre 139.0 9.187.3.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67mm x 52mm) metre 539.0 9.187.4.2 Sliding Door Sash (80mm x 44mm) metre 653.0 9.187.4.3 Sliding Interlock for Door (one vertical length in each shutter) (45.5 mm x 28 mm) metre 139.0 9.187.4.4 Sliding Glazing bead (35 mm x 18 mm) metre 178.0 106 9.188 9.188.1 200 x 19 x 1.9 mm each 321.0 9.188.2 250 x 19 x 1.9 mm each 369.0 9.188.3 300 x 19 x 1.9 mm each 462.0 9.188.4 350 x 19 x 1.9 mm each 526.0 9.188.5 400 x 19 x 1.9 mm each 636.0 107 9.189 108 9.191 109 9.192 110 9.193 111 9.194 9.194.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) sqm 6798.0 9.194.2 Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). sqm 6221.0 9.194.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 2.50 sqm). sqm 4842.0 9.194.4 Casement window single panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 0.75 sqm.) sqm 6681.0 9.194.5 Casement window duble panel with S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.50 sqm.) sqm 6942.0 9.194.6 Casement cum fixed panel window having both and single casement panel, middle fixed panels and at top completely fixed ventilator with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash 67 x 80 mm & mullion67 x 80 all having wall thickness of 2.3 ±0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 3.00 sqm. Upto 5.00 sqm.) sqm 5290.0 9.195 Providing and fixing factory made UPVC white colour fixed glazed windows/ ventilators comprising of UPVC multi- chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), UPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (ifrequired) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. Afterfixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). 9.195.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) sqm 4860.0 9.196 Providing and fixing made UPVC white colour casement/ casement cum fixed glazed door comprising of UPVC multi- chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made fromroll forming process of required length(shape & size according to UPVC profile),UPVC 9.196.1 Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). sqm 7085.0 9.196.2 Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±.0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm). sqm 7063.0 9.197 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of UPVC multi-chambered frame with in- built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension of UPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) 9.197.1 Two track two panels sliding window made of frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) sqm 5060.0 9.197.2 Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). sqm 6880.0 9.197.3 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension (Area of window above 1.75 sqm upto 2.50 sqm). sqm 5134.0 9.197.4 Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area ofwindow above 1.75 sqm). sqm 6371.0 9.197.5 Three track three panels sliding window made of frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) sqm 5913.0 112 9.198 9.198.1 Two track two panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 2.50 sqm upto sqm 4332.0 4.00 sqm). 9.198.2 Two track four panels sliding window made of frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm). sqm 3532.0 9.199 Providing and fixing factory made UPVC white colour sliding glazed door comprising of UPVC multi-chambered frame with in- built roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension UPVC extruded glazing beads, UPVC extruded interlock and UPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), 9.199.1 Two track two panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 10.00 sqm). sqm 3676.0 9.199.2 Two track four panels sliding door made of frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 8.00 sqm upto10.00 sqm). sqm 3810.0 9.199.3 Three track three panels sliding door made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of door above 5.00 sqm) sqm 4361.0 9.199.4 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mmand single glazing bead / double glazing bead of appropriate dimension. (Area ofdoor above 2.00 sqm upto 5.00 sqm) sqm 5617.0 9.2 Providing and fixing 30mm thick factory made solid panel prelaminated PVC internal door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 40mm x 20mm for styles top, lock and bottom rails. M.S.frame shall have a coat of steel primers of approved make and manufacture.M.S. frame sqm 3908.0 113 9.201 9.201.1 24 to 25 mm thick plain solid PVC flush door shutter sqm 2250.0 9.201.2 28 to 30 mm thick plain solid PVC flush door shutter sqm 3229.0 114 9.202 9.202.1 1mm thick laminated sheet sqm 3693.0 9.202.2 0.12 mm thick laminated sheet sqm 3461.0 115 9.255 9.255.1 9 mm thick BWP grade commercial Sqm 841.0 plywood 9.255.2 12 mm thick BWP grade commercial Sqm 1064.0 plywood 9.255.3 18 mm thick BWP grade commercial Sqm 1169.0 plywood 9.255.4 25 mm thick BWP grade commercial Sqm 1366.0 plywood 116 9.256 9.256.1 25 mm outer dia & 300 mm long Each Set 984.0 9.256.2 32 mm outer dia & 450 mm long Each Set 1716.0 9.256.3 32 mm outer dia & 600 mm long Each Set 2041.0 117 9.257 9.196, 9.197, 9.198, 9.199) 118 9.258 9.258.1 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1040.0 119 10.7 10.7.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area. sqm 747.0 10.7.2 Exceeding 16.80 sqm in area. sqm 782.0 120 10.11 10.11.1 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). kg 77.0 121 10.12 10.12.1 Profile B of 1.60mm thick single rebate of size 80mmx50mm 10.12.1.1 Fixing with adjustable lugs with split end tail to each jamb. meter 402.0 10.12.1.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 394.0 10.12.2 Profile C of 1.60mm thick single rebate of size 100mmx50mm 10.12.2.1 Fixing with adjustable lugs with split end tail to each jamb. meter 431.0 10.12.2.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 424.0 10.12.3 Profile E of 1.60mm thick double rebate of size 115mmx50mm 10.12.3.1 Fixing with adjustable lugs with split end tail to each jamb. meter 472.0 10.12.3.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 464.0 10.12.4 Profile B of 1.25mm thick single rebate of size 80mmx50mm 10.12.4.1 Fixing with adjustable lugs with split end tail to each jamb. meter 356.0 10.12.4.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 348.0 10.12.5 Profile C of 1.25mm thick single rebate of size 100mmx50mm 10.12.5.1 Fixing with adjustable lugs with split end tail to each jamb. meter 385.0 10.12.5.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 377.0 10.12.6 Profile E of 1.25mm thick double rebate of size 115mmx50mm 10.12.6.1 Fixing with adjustable lugs with split end tail to each jamb. meter 414.0 10.12.6.2 Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately). meter 406.0 122 10.14 10.14.1 Hot finished welded type tubes kg 117.0 10.14.2 Hot finished seamless type tubes kg 123.0 10.14.3 Electric resistance or induction butt welded tubes. kg 142.0 10.15 Design, supply, fabrication, taransportion and erection of structural steel/mild steel built-up sections for steel building in column, rafter, truss, floor joist, wind bracings, tie beam, foundation bolts, fasteners etc. Including two coats ofEpoxy paint and one coat of primer. These structural steel/built-up sections shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code. kg 132.0 123 10.17 124 10.18 125 10.19 126 10.21 127 10.22 10.22.1 In stringers, treads, landings etc. of stair cases including use of chequered plate wherever required, all complete. kg 101.0 10.22.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. kg 105.0 128 10.23 10.23.1 M.S. tube. kg 117.0 10.23.2 E.R.W. tubes. kg 132.0 129 10.25 130 10.26 10.26.1 Galvanised M.S. Wire gauze with 0.63mm dia wire and 1.4 mm aperture on both sides sqm 646.0 10.26.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. sqm 1334.0 131 10.27 10.27.1 With 4.0 mm thick glass panes sqm 792.0 10.27.2 With 5.50 mm thick glass panes sqm 873.0 10.27.3 With 1mm thick mild steel sheet i/c 10x10x1.6mm box beading. sqm 916.0 10.27.4 With 2mm thick fibre reinforced polymer (FRP) sheet i/c 10x10x1.6mm boxbeading. sqm 611.0 10.27.5 With 1mm thick Galvanised steel sheet i/c 10x10x1.6mm box beading. sqm 936.0 10.27.6 With 4mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 750.0 10.27.7 With 6mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 800.0 10.27.8 With 8mm thick cement fibre board conforming to IS 14862:2000 of category type A grade i/c 10x10x1.6mm box beading. sqm 872.0 132 10.28 10.28.1 With 4.0 mm thick glass panes. sqm 259.0 10.28.2 With 5.5 mm thick glass panes. sqm 262.0 133 10.29 134 11.19 11.19.1 Makrana white second quality. sqm 3051.0 11.19.2 Raj Nagar plain. sqm 1381.0 11.19.3 Agaria White/Morgarh sqm 1882.0 11.19.4 Katni marble sqm 1555.0 11.19.5 Black Zebra. sqm 1315.0 11.19.6 Udaipur / Baroda green marble sqm 1649.0 11.19.7 Pink plain marble. sqm 1448.0 11.19.8 Jaisalmer Yellow sqm 1582.0 135 11.2 11.20.1 Makrana white second quality. sqm 3675.0 11.20.2 Raj Nagar plain. sqm 1932.0 11.20.3 Agaria White/Morgarh sqm 2455.0 11.20.4 Katni marble sqm 2113.0 11.20.5 Black Zebra. sqm 1863.0 11.20.6 Udaipur / Baroda green marble sqm 2211.0 11.20.7 Pink plain marble. sqm 2002.0 11.20.8 Jaisalmer Yellow sqm 2141.0 136 11.21 11.21.1 Makrana white second quality. sqm 3773.0 11.21.2 Raj Nagar plain. sqm 2737.0 11.21.3 Agaria White/Morgarh sqm 2553.0 11.21.4 Katni marble sqm 2219.0 11.21.5 Black Zebra. sqm 1961.0 11.21.6 Udaipur / Baroda green marble sqm 2309.0 11.21.7 Pink plain marble. sqm 2100.0 11.21.8 Jaisalmer Yellow sqm 2240.0 137 11.22 11.22.1 Raj Nagar plain/White Marble/Udaipur Green Marble /Zebra black sqm 1797.0 11.22.2 Granite fine grained dark crystal of other colours and various patterns sqm 2356.0 11.22.3 Granite coarse grained light black/ light red/white with crystal of other colours and various patterns Sqm 2113.0 11.22.4 Granite grey/pink/brown with various patterns Sqm 1808.0 11.22.5 Cuddpah stone sqm 1279.0 138 11.23 139 11.24 140 11.25 141 11.29 11.29.1 Area of slab over 0.50 sqm 11.29.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2919.0 11.29.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2675.0 11.29.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2370.0 11.29.2 Area of slab upto 0.50 sqm 11.29.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2705.0 11.29.2.2 Coarse grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2486.0 11.29.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2212.0 142 11.3 11.30.1 Area of slab over 0.50 sqm 11.30.1.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2642.0 11.30.1.2 Coarse grained granite light Black/light Red/ off White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2422.0 11.30.1.3 Gray/Pink/Brown or equivalent with various patterns sqm 2153.0 11.30.2 Area of slab upto 0.50 sqm 11.30.2.1 Fine grained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2455.0 11.30.2.2 Coarsegrained granite dark Black/dark Red/ White or equivalent with self design/ pattern/crystals of other colors of glitter sqm 2258.0 11.30.2.3 Gray/Pink/Brown or equivalent with various patterns sqm 2011.0 patterns 143 11.32 144 11.33 11.33.1 Flamed Finish Granite sqm 2542.0 11.33.2 Leather Finish Granite sqm 2809.0 145 11.34 146 11.36 Note: - Deduction shall be made for not mirror polishing according to item no 11.43 147 11.37 148 11.38 11.38.1 10-12 mm thick sqm 1177.0 11.38.2 20 mm thick sqm 1231.0 149 11.39 150 11.4 11.40.1 Marble work meter 164.0 11.40.2 Granite work. meter 269.0 151 11.41 152 11.42 153 11.43 154 11.44 11.44.1 Red sand stone sqm 578.0 11.44.2 White sand stone sqm 578.0 11.44.3 Grey lime stone sqm 578.0 11.44.4 Kota stone sqm 678.0 155 11.47 156 11.48 157 11.49 158 11.52 159 11.53 160 11.54 161 11.55 162 11.56 163 12.63 11.63.1 Fastener with threaded dia 6 mm. each 25.0 11.63.2 Fastener with threaded dia 10 mm. each 29.0 11.63.3 Fastener with threaded dia 12 mm. each 46.0 164 11.66 165 11.72 proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction byusing plate vibrator, filling the joints with sand and cutting of paver blocks as per required sizeand pattern, finishing and sweeping extra sand including locking with M15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturers specifications and direction of Engineer-in-Charge. 11.72.1 80 mm thick C.C. paver block of M-35 grade sqm 805.0 11.72.2 60 mm thick C.C. paver block of M-35 grade sqm 680.0 11.72.3 60 mm thick C.C. paver block of M-30 grade sqm 605.0 166 11.75 including fixing of granite stone door frame with epoxy resin based adhesive including secured to the backing by means of cramps, drilling of hole with rawl plugs and screws 75mm long cleaning etc. complete. Including rubbing, curing, moulding and polishing edges to give high glossy finish and drilling of hole for fixing stainless steel hings, aldrop, towerboltetc complete at all levels as per instruction of Engineer-in-Charge. 11.75.1 Granite Door frame for 100mm thick wall Thickness. metre 1010.0 11.75.2 Granite Door frame for 200mm thick wall Thickness. metre 1512.0 167 11.76 11.76.1 Plain ivory light shade sqm 950.0 Size 600X600mm thickness 9-10mm 11.76.2 Dark shade (terracotta) sqm 1033.0 Size 600X600mm thickness 9-10mm 168 11.77 11. 77.1 Plain ivory light shade sqm 940.0 Size 600X600mm thickness 9-10mm 11. 77.2 Dark shade (terracotta) sqm 1022.0 Size 600X600mm thickness 9-10mm 169 11.8 11.80.1 In light colour and shades as ivory, beige blanco, grey etc. 11.80.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 934.0 11.80.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1206.0 11.80.1.3 (c) Size 600X600 mm thickness 11-12mm (to be used heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1349.0 11.80.2 In dark colour and shade etc. 11.80.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 946.0 11.80.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1340.0 11.80.2.3 (c) Size 600X600 mm thickness 11-12mm (to be used in heavy duty indoor areas of non residencial buildings only such as schools, hostels, libraries hospitals, institutions, offices etc.) sqm 1546.0 170 11.81 11. 81.1 In light colour and shades as ivory, beige blanco, grey etc. 11. 81.1.1 (a) Size 300X300 mm thickness 9-10 mm sqm 923.0 11. 81.1.2 (b) Size 600X600mm thickness 9-10mm sqm 1196.0 11. 81.2 In dark colour and shades etc. 11. 81.2.1 (a) Size 300X300 mm thickness 9-10 mm sqm 935.0 11. 81.2.2 (b) Size 600X600mm thickness 9-10mm sqm 1329.0 171 11.82 11. 82.1 For floor glossy/ rustic /stain/matt finished laid on 20mm thick cement mortar 1:4 (1 cement:4sand) 11. 82.1.1 Size 600X600 mm thickness 9-10 mm sqm 1140.0 11. 82.1.2 Size 800X800mm thickness 9-10 mm sqm 1261.0 11. 82.1.3 Size 800X1600mm thickness 9-10 mm sqm 1489.0 11. 82.1.4 Size 1000X1000mm thickness 9-10 mm sqm 1388.0 11. 82.1.5 Size 600X1200 mm thickness 9-10 mm sqm 1235.0 11. 82.1.6 Size 800X1200 mm thickness 9-10 mm sqm 1450.0 11. 82.1.7 Size 1200X1200 mm thickness 9-10 mm sqm 1596.0 11. 82.1.8 Size 1200X1800mm thickness 9-10 mm sqm 1715.0 11. 82.1.9 Size 1200X2400 mm thickness 9-10 mm sqm 2403.0 172 11.83 11. 83.1 For skirting, riser, dado and wall lining etc.glossy/ rustic /stain/mattfinished in all colours and shades 11. 83.1.1 Size 300X600 mm thickness 9-10 mm sqm 1048.0 11. 83.1.2 Size 600X600 mm thickness 9-10 mm sqm 1129.0 11. 83.1.3 Size 800X800mm thickness 11-12mm sqm 1250.0 11. 83.1.4 Size 600X1200 mm thickness 11-12mm sqm 1224.0 11. 83.1.5 Size 800X1200 mm thickness 11-12mm sqm 1440.0 173 11.84 11. 84.1 Area of tiles not less 0.18 sqm 11. 84.1.1 Fine granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 2296.0 11. 84.1.2 Course granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 2113.0 11. 84.1.3 Gray/Pink/Brown with various patterns sqm 1879.0 174 11.85 11. 85.1 Area of tiles not less 0.18 sqm 11. 85.1.1 Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter sqm 1775.0 11. 85.1.2 Coarse grained granite light Black/light Red/ off White with crystals of other colors and various patterns sqm 1610.0 11. 85.1.3 Gray/Pink/Brown with various patterns sqm 1404.0 175 11.97 Size 800X1600 mm thickness 8-9 mm Sqm 1778.0 176 11.102 177 11.103 178 12.4 12.4.1 0.80mm thick with zinc coating not less than 275gm/m² meter 500.0 12.4.2 0.63mm thick with zinc coating not less than 275gm/m² meter 431.0 179 12.7 12.7.1 0.80mm thick with zinc coating not less than 275gm/m² meter 459.0 12.7.2 0.63mm thick with zinc coating not less than 275gm/m² meter 402.0 180 12.12 12.12.1 Corrugated serrated adjustable ridges meter 367.0 12.12.2 Plain wing adjustable ridges meter 311.0 12.12.3 Close fitting adjustable ridges meter 420.0 12.12.4 Unserrated adjustable hips meter 506.0 181 12.13 12.13.1 Corrugated apron pieces meter 340.0 12.13.2 Eaves filler pieces meter 232.0 12.13.3 North light curves meter 500.0 12.13.4 ventilator curves meter 622.0 12.13.5 Barge boards meter 623.0 12.13.6 Ridge finials pair 229.0 12.13.7 Special north light curves each 753.0 12.13.8 S type louvers meter 418.0 182 12.14 183 12.15 primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 184 12.16 12.16.1 Ridges plain (500 - 600mm). meter 320.0 12.16.2 Flashings/ Aprons.( Upto 600 mm) meter 284.0 12.16.3 North light curves. meter 341.0 12.16.4 Barge board (Upto 300 mm) meter 274.0 12.16.5 Crimp curve sqm 315.0 12.16.6 Gutter. (600 mm over all girth) meter 781.0 185 12.17 12.17.1 2mm thick corrugated (2.5 or 4.2 or 6) or step-down (2or 3or 6) as specified. sqm 1031.0 12.17.2 2mm thick flat. sqm 955.0 186 12.23 187 12.24 188 12.26 189 12.27 190 12.32 12.32.1 75 mm diameter (minimum wall thickness 1.8mm) metre 136.0 12.32.2 110 mm diameter (minimum wall thickness 2.2mm) metre 238.0 191 12.33 12.33.1 Coupler 12.33.1.1 75 mm (minimum wall thickness 1.8mm) each 67.0 12.33.1.2 110 mm (minimum wall thickness 2.2mm) each 102.0 12.33.2 Single push fit Coupler : 12.33.2.1 75 mm (minimum wall thickness 1.8mm) each 121.0 12.33.2.2 110 mm (minimum wall thickness 2.2mm) each 94.0 12.33.3 Single tee with door 12.33.3.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.3.2 110x110x110 mm (minimum wall thickness 2.2mm) each 176.0 12.33.4 Single tee without door 12.33.4.1 75x75x75 mm (minimum wall thickness 1.8mm) each 106.0 12.33.4.2 110x110x110 mm (minimum wall thickness 2.2mm) each 163.0 12.33.5 Bend 87.5° 12.33.5.1 75 mm bend (minimum wall thickness 1.8mm) each 78.0 12.33.5.2 110 mm bend (minimum wall thickness 2.2mm) each 112.0 12.33.6 Shoe (Plain) 12.33.6.1 75 mm Shoe (minimum wall thickness 1.8mm) each 69.0 12.33.6.2 110 mm Shoe (minimum wall thickness 2.2mm) each 99.0 192 12.34 12.34.1 75 mm (minimum wall thickness 1.8mm) each 97.0 12.34.2 110 mm (minimum wall thickness 2.2mm) each 114.0 hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in adirection perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.58.1 10mm thick plaster of Paris (gypsum anhydrous) sheet 10mm thick pop board. 12.58.1.1 Flat surfaces sqm 676.0 12.58.1.2 Curved surfaces sqm 748.0 12.58.1.3 Sunk or raised mouldings sqm 175.0 12.58.1.4 Extra for providing in the plaster of Paris (Gypsum anhydrous) ceiling above 5 metre height from floor level. sqm per meter height 59.0 12.58.2 12.5 mm thick tapered edge gypsum board 12.58.2.1 Plain board conforming to IS: 2095- Part I: 2011 (Board with BIS certification marks). sqm 750.0 12.58.2.2 Fire resistant Glass ReinforcedGypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) sqm 866.0 12.58.2.3 12.5mm thick moisture resistant gypsum plasterboards Moistbloc as per BS EN 520 confirming to water absorption class H1 with total water absorption < 5%, Green Pro certified by CII sqm 920.0 12.58.2.4 Fully Perforated Gypsum Plaster Board having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturersspecification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60. sqm 1277.0 12.58.3 8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured throughautoclaving process. sqm 1150.0 193 13.1 13.1.1 1:4 (1 cement : 4 sand) sqm 173.0 13.1.2 1:6 (1 cement : 6 sand) sqm 160.0 194 13.2 13.2.1 1:4 (1 cement : 4 sand) sqm 184.0 13.2.2 1:6 (1 cement : 6 sand) sqm 168.0 195 13.3 13.3.1 1:4 (1 cement : 4 sand) sqm 245.0 13.3.2 1:6 (1 cement : 6 sand) sqm 225.0 196 13.4 13.4.1 1:3 (1 cement : 3 sand) sqm 210.0 13.4.2 1:4 (1 cement : 4 sand) sqm 203.0 197 13.5 13.5.1 1:3 (1 cement : 3 sand) sqm 236.0 13.5.2 1:4 (1 cement : 4 sand) sqm 220.0 198 13.13 199 13.14 200 13.15 13.15.1 Exterior walls of height more than 10 m from ground for every additional height of 3 m or part thereof sqm 34.0 13.15.2 Interior walls of height more than 6 m from floor level for every additional height of 3 m or part thereof sqm 22.0 201 13.16 13.16.1 In one coat sqm 11.0 13.16.2 In two coats sqm 18.0 202 13.17 13.17.1 In one coat sqm 158.0 13.17.2 In two coats sqm 260.0 203 13.18 13.18.1 Spherical ceiling sqm 42.0 13.18.2 Groined ceiling sqm 47.0 13.18.3 Flewing soffits sqm 28.0 204 13.38 205 13.39 13.39.1 Providing and applying plaster of paris punning of 10 mm average thickness over plastered surface to prepare the surface even and smooth complete. sqm 130.0 13.39.2 Extra for making 12mm flute grove with 6 mm depth to prepare the surface even and smooth complete. metre 70.0 206 13.41 207 13.43 208 13.44 209 13.45 210 13.46 211 13.47 13.47.1 One coat. sqm 20.0 13.47.2 Two coats. sqm 32.0 212 13.48 13.48.1 One coat. sqm 37.0 13.48.2 Two coats. sqm 56.0 213 13.49 214 13.51 215 13.52 216 13.53 217 13.54 218 13.54.1 219 13.54.2 220 13.54.3 221 13.55 13.55.1 One coat sqm 63.0 13.55.2 Two coats sqm 101.0 222 13.64 223 13.65 224 13.66 13.66.1 One coat. sqm 35.0 13.66.2 Two coats. sqm 53.0 225 13.68 226 13.71 227 13.77 228 13.8 13.80.1 0.8-1.2mm thickness sqm 368.0 13.80.2 2.0-2.5mm thickness sqm 338.0 229 13.81 effective for 90 Days(03 Months) . 230 13.103 Note:- Applicable to item No. 13.1 to item No. 13.10 231 13.105 13.105.1 Standard pattern and design wallpaper Sqm 615.0 13.105.2 3D pattern and design wallpaper Sqm 750.0 13.105.3 Customize design wallpaper Sqm 1145.0 232 14.5 14.5.1 Float glass panes of thickness 4 mm sqm 679.0 14.5.2 Float glass panes of thickness 5.5 mm sqm 759.0 233 14.6 14.6.1 Float glass panes of thickness 4 mm sqm 801.0 14.6.2 Float glass panes of thickness 5.5 mm sqm 882.0 234 14.7 14.7.1 Float glass panes of thickness 4 mm sqm 697.0 14.7.2 Float glass panes of thickness 5.5 mm sqm 778.0 235 14.8 14.8.1 2nd class teak wood fillets meter 30.0 14.8.2 Haldu/Bija/Kail wood fillets. meter 26.0 236 14.11 237 14.24 238 14.27 239 14.28 240 14.29 241 14.31 242 14.36 243 14.37 244 14.38 245 14.39 246 14.48 247 14.49 14.49.1 Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 liters/10 sqm complete including cost of Priming coat. sqm 42.0 14.49.2 Old work (one or more coats @ 2.20 kg/10 sqm) complete. sqm 30.0 248 14.51 14.51.1 Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). sqm 87.0 14.51.2 Old work (One or more coat applied @ 0.90 ltr/10 sqm). sqm 52.0 249 14.52 14.52.1 Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface. sqm 65.0 14.52.2 Old work (one or more coats applied @ 0.83 ltr/10 sqm). sqm 41.0 250 14.53 14.53.1 One or more coats applied on walls @ 0.85 ltr/10 sqm. sqm 58.0 251 14.62 14.62.1 (one or more coats) sqm 9.0 14.62.2 (two or more coats) sqm 11.0 252 15.2 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). cum 578.0 15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). cum 356.0 253 15.6 15.6.1 In lime mortar with old mughal bricks. cum 421.0 15.6.2 In lime mortar. cum 202.0 15.6.3 In cement mortar. cum 487.0 254 15.7 15.7.1 From brick work in lime mortar. 1000 nos 1254.0 15.7.2 From brick work in cement mortar. 1000 nos 1560.0 255 15.8 15.8.1 In lime mortar. cum 275.0 15.8.2 In cement mortar. cum 582.0 256 15.13 257 15.14 15.14.1 Of area 3 sq. metres and below. each 85.0 15.14.2 Of area beyond 3 sq. metres. each 117.0 258 15.15 15.15.1 Of area 3 sq. metres and below. each 33.0 15.15.2 Of area beyond 3 sq. metres. each 44.0 259 15.47 260 15.48 261 15.49 262 15.51 15.51.1 Rectangular manhole 90x80 cm and 45 cm deep each 611.0 15.51.2 Rectangular manhole 120x90 cm and 90 cm deep. each 1069.0 15.51.3 Rectangular arch type manhole 140x90cm and 2.45m deep. each 2023.0 15.51.4 Circular manhole 122 cm diameter and 1.68 m deep each 1553.0 263 15.52 15.52.1 Rectangular manhole 90x80 cm and beyond 45 cm depth. each 486.0 15.52.2 Rectangular manhole 120x90 cm and beyond 90 cm depth. each 579.0 15.52.3 Rectangular arch type manhole 140x90 cm and beyond 2.45m deep (upto 4.25 m depth). each 468.0 15.52.4 Circular manhole 122 cm diameter and beyond 1.68 m deep (upto 2.29 m depth). each 322.0 264 15.64 265 17.1 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. each 2995.0 266 17.2 17.2.1 W.C. pan with ISI marked white solid plastic seat and lid. each 3036.0 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid. each 3013.0 267 17.3 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid. each 4613.0 17.3.2 W.C. pan with ISI marked black solid plastic seat and lid. each 4590.0 268 17.11 17.11.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. each 2187.0 17.11.3 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tap. each 1938.0 17.11.4 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. each 1664.0 17.11.5 White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap. each 1775.0 269 17.12 270 17.14 17.14.1 Kitchen sink with drain board 17.14.1.1 510x1040 mm bowl depth 250mm. each 8074.0 17.14.1.2 510x1040 mm bowl depth 225mm. each 7609.0 17.14.1.3 510x1040 mm bowl depth 200mm. each 7493.0 17.14.1.4 510x1040 mm bowl depth 178mm. each 5286.0 17.14.2 Kitchen sink without drain board 17.14.2.1 610x510 mm bowl depth 200 mm. each 4583.0 17.14.2.2 610x460 mm bowl depth 200 mm. each 4351.0 17.14.2.3 470x420 mm bowl depth 178 mm. each 3422.0 271 17.22 17.22.1 White each 945.0 17.22.2 coloured each 1037.0 272 17.24 17.24.1 White each 456.0 17.24.2 Black each 433.0 17.24.3 Coloured (other than black and white) each 688.0 273 17.25 274 17.6 17.60.1 75 mm each 33.0 17.60.2 110 mm each 50.0 275 17.61 276 17.64 17.64.1 Semi rigid pipe 17.64.1.1 32 mm dia each 87.0 17.64.1.2 40 mm dia each 98.0 17.64.2 Flexible pipe (only in residential & complaxes) 17.64.2.1 32 mm dia each 87.0 17.64.2.2 40 mm dia each 98.0 277 17.65 278 17.67 279 17.67 17.68.1 Circular shape 450mm dia. each 806.0 17.68.2 Rectangular shape 453x357mm each 642.0 17.68.3 Oval shape 450x350mm (outer dimensions) each 697.0 17.68.4 Rectangular shape 1500x450 mm each 1311.0 280 17.69 281 17.7 17.70.1 C.P. brass each 340.0 17.70.2 Vitreous china each 324.0 282 17.74 283 17.75 284 17.76 285 18.6 18.6.1 Internal work - Exposed on wall 18.6.1.1 15 mm nominal outer dia .Pipes metre 129.0 18.6.1.2 20 mm nominal outer dia .Pipes metre 153.0 18.6.1.3 25 mm nominal outer dia .Pipes metre 177.0 18.6.1.4 32 mm nominal outer dia .Pipes metre 254.0 18.6.1.5 40 mm nominal outer dia .Pipes metre 354.0 18.6.1.6 50 mm nominal outer dia .Pipes metre 528.0 18.6.2 Concealed work including cutting chases and making good the walls etc. 18.6.2.1 15 mm nominal outer dia .Pipes metre 207.0 18.6.2.2 20 mm nominal outer dia .Pipes metre 234.0 18.6.2.3 25 mm nominal outer dia .Pipes metre 288.0 18.6.2.4 32 mm nominal outer dia .Pipes metre 360.0 286 18.7 External Work 18.7.1 15 mm nominal outer dia .Pipes metre 122.0 18.7.2 20 mm nominal outer dia .Pipes metre 141.0 18.7.3 25 mm nominal outer dia .Pipes metre 185.0 18.7.4 32 mm nominal outer dia .Pipes metre 238.0 18.7.5 40 mm nominal outer dia .Pipes metre 324.0 18.7.6 50 mm nominal outer dia .Pipes metre 498.0 18.7.7 62.50 mm nominal inner dia .Pipes. metre 1429.0 18.7.8 75 mm nominal inner dia .Pipes. metre 2018.0 18.7.9 100mm nominal inner dia .Pipes. metre 2791.0 18.7.10 150 mm nominal inner dia .Pipes. metre 3358.0 287 18.13 18.13.1 25 mm nominal bore each 428.0 18.13.2 32 mm nominal bore. each 500.0 18.13.3 40 mm nominal bore each 584.0 18.13.4 50 mm nominal bore each 749.0 288 18.14 18.14.1 15 mm nominal bore each 316.0 18.14.2 20 mm nominal bore each 431.0 18.14.3 25 mm nominal bore each 499.0 289 18.17 18.17.1 30 cm length 18.17.1.1 15 mm nominal bore each 88.0 18.17.1.2 20 mm nominal bore each 129.0 18.17.2 45 cm length 18.17.2.1 15 mm nominal bore each 149.0 18.17.2.2 20 mm nominal bore each 184.0 290 18.18 18.18.1 With common burnt clay bricks of 25 kg /sqcm compressive strength. each 916.0 18.18.2 With well burnt flyash bricks of 50 kg/sqm compressive strength. each 870.0 291 18.28 292 18.29 18.29.1 15 mm nominal bore each 306.0 18.29.2 20 mm nominal bore each 338.0 293 18.3 18.30.1 15 mm nominal bore each 318.0 18.30.2 20 mm nominal bore each 344.0 294 18.31 295 18.32 296 18.33 297 18.34 298 18.35 299 18.36 300 18.37 301 18.38 302 18.39 303 18.41 304 18.42 305 18.43 18.43.1 100 mm diameter each 806.0 18.43.2 150 mm diameter each 922.0 18.43.3 200 mm diameter each 1336.0 306 18.64 307 18.65 308 18.67 309 18.68 18.68.1 300 mm long each 450.0 18.68.2 600 mm long each 650.0 310 19.4 19.4.1 110 mm diameter OD (min. wall thickness 3.2mm) metre 234.0 19.4.2 160 mm diameter OD (min. wall thickness 4.0 mm) metre 477.0 19.4.3 200 mm diameter OD (min. wall thickness 4.9 mm) metre 751.0 19.4.4 250 mm diameter OD (min. wall thickness 6.2mm) metre 972.0 19.4.5 300 mm diameter OD (min. wall thickness 7.7mm) metre 1232.0 311 19.5 19.5.1 110 mm diameter PVC. pipe metre 576.0 19.5.2 160 mm diameter PVC. pipe metre 704.0 19.5.3 200 mm diameter PVC. pipe metre 821.0 19.5.4 250 mm diameter PVC. pipe metre 949.0 19.5.5 300 mm diameter PVC pipe metre 1078.0 312 19.6 19.6.1 110 mm diameter PVC. pipe metre 274.0 19.6.2 160 mm diameter PVC. pipe metre 444.0 19.6.3 200 mm diameter PVC. pipe metre 521.0 19.6.4 250 mm diameter PVC. Pipe metre 607.0 19.6.5 300 mm diameter PVC pipe metre 700.0 313 19.7 19.7.1 100x100 mm size P type 19.7.1.1 With well burnt bricks each 1764.0 19.7.1.2 With Sewer bricks conforming to IS : 4885 each 1668.0 19.7.2 150 x 100 mm size P type. 19.7.2.1 With well burnt bricks each 1803.0 19.7.2.2 With sewer bricks conforming to IS : 4885 each 1707.0 19.7.3 180x150 mm size P type 19.7.3.1 With well burnt bricks each 1913.0 19.7.3.2 With Sewer bricks conforming to IS : 4885 each 1818.0 314 19.9 19.9.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.9.1.1 With well burnt bricks each 7997.0 19.9.1.2 With Sewer bricks conforming to IS : 4885 each 7747.0 19.9.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight offrame 58 kg) : 19.9.2.1 With well burnt bricks each 18086.0 19.9.2.2 With Sewer bricks conforming to IS : 4885 each 17402.0 19.9.3 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) 19.9.3.1 With well burnt bricks each 21816.0 19.9.3.2 With Sewer bricks conforming to IS : 4885 each 21228.0 315 19.1 19.10.1 Size 90x80 cm 19.10.1.1 With well burnt bricks metre 6176.0 19.10.1.2 With Sewer bricks conforming to IS : 4885 metre 5448.0 19.10.2 Size 120x90 cm 19.10.2.1 With well burnt bricks metre 7380.0 19.10.2.2 With Sewer bricks conforming to IS : 4885 metre 6512.0 316 19.12 19.12.1 With well burnt bricks metre 5257.0 19.12.2 With Sewer bricks conforming IS : 4885 metre 4648.0 317 21.1 21.1.1 For fixed portion. 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 378.0 21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 416.0 21.1.1.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 426.0 21.1.2 For shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings whereverrequired including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). 21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) kg 446.0 21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 484.0 21.1.2.3 Polyester powder coated aluminium (minimum thicknessof polyester powder coating 50 micron) kg 494.0 21.1.3 Deduct for not providing EDPM rubber/neoprene gasket all around. kg 80.0 318 21.2 21.2.1 Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. sqm 802.0 21.2.2 Pre-laminated particle board with decorative lamination on both sides. sqm 907.0 319 21.3 21.3.1 With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm) sqm 774.0 21.3.2 With float glass panes of 5.0 mm thickness (weight not less than sqm 948.0 12.50 kg/sqm ) 21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm ). sqm 1182.0 320 21.5 21.5.1 With stainless steel cover plate - minimum 1.25 mm thickness each 1890.0 21.5.2 With brass cover plate - minimum 1.25 mm thickness. each 2072.0 321 21.16 21.16.1 Anodized (AC15 ) aluminium each 62.0 21.16.2 Powder coated minimum thickness 50 micron aluminium each 65.0 21.16.3 Polyester powder coated minimum thickness 50 micron aluminium. each 69.0 322 21.17 323 21.18 324 21.19 325 21.21 326 21.22 327 21.23 328 21.24 329 21.32 330 22.6 a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. 331 22.14 22.14.1 Cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cum 6569.0 22.14.2 Cement mortar 1:3 (1 cement : 3 sand) cum 9308.0 22.14.3 Cement mortar 1:4 (1cement : 4 sand) cum 8437.0 332 25.1 25.1.1 White Vitreous china Anti germ Fluoro-Polymer coated Orissa Pattern W. C. Pan of Size 440X575X250mm With integral foot rests. (Premium Range) each 4726.0 25.1.2 White Vitreous china Anti germ Fluoro-Polymer coated Orissa pattern W. C. pan of size 410X515X255 mm with integral foot rests.(Premium Range) each 4392.0 333 25.2 25.2.1 Anti-germ Fluoro-Polymer Coated (nano coating) European W. C. pan Size 360X545X395 with solid poly propelyne made soft closing seat cover (Premium Range) each 9788.0 25.2.2 Anti-germ Fluoro-Polymer Coated Water Closet European type W. C. pan size 360X475X395 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 8742.0 334 25.3 25.3.1 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet Size 380X520X375 mm with solid poly propelyne made soft closing seat cover (Premium Range) each 26412.0 25.3.2 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 390X570X365 mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 23559.0 25.3.3 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm with solid poly propelyne made, soft closing seat cover (Premium Range) each 21099.0 25.3.4 Anti germ Fluoro-Polymer Coated (Nano coating) Wall hung water closet size 360 x 500 x 330mm or greater size with solid poly propelyne made, soft closing seat cover (Premium Range) each 18838.0 335 25.4 25.4.1 Anti germ Fluoro-Polymer Coated couple water closet Size 420X710X810mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 28103.0 25.4.2 Anti germ Fluoro-Polymer Coated couple water closet Size 380X610X805mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 19275.0 25.4.3 Anti germ Fluoro-Polymer Coated couple water closet Size 370 x 640 x 760mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18952.0 25.4.4 Anti germ Fluoro-Polymer Coated couple water closet Size 375X650X800 mm with solid poly propelyne made soft closing seat cover. (Premium Range) each 18023.0 336 25.5 25.5.1 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) Each 34317.0 25.5.2 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 25954.0 25.5.3 Anti germ Fluoro-Polymer Coated Single PieceW.C. Pan Size 385X720X710mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 22237.0 25.5.4 Anti germ Fluoro-Polymer Coated Single Piece W.C. Pan Size 370X695X795mm with solid poly propelyne made soft closing seat cover.(Premium Range) each 19450.0 337 25.6 25.6.1 Anti germ Fluoro-Polymer Coated extended wall hung type couple closet Size 380X650X730mm with solid poly propelyne made soft closing seat cover (Premium Range) each 13365.0 25.6.2 Providing and fixing white vitreous china made Anti germ fluoro-polymer coated extended wall hung type couple closet Size 375X360X750mm along with dual flushing cistern flushing capacity 3 & 6 litre. (Premium Range) each 10670.0 338 25.7 25.7.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595X435X185 mm with basin mounted pressmatic pillar cock auto closing system (decol technology). (Premium Range) each 16581.0 339 25.8 25.8.1 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570x415x200mm with 15 mm C. P. wall mounted pressmatic Pillar cock auto closing system with square wall flance & spout complete (decol technology). (Premium Range) each 14543.0 25.8.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 570X820X195mm with 15 mm C. P. Table Top pressmatic Pillar cock auto closing system (decol technology). (Premium Range) each 13614.0 340 25.9 25.9.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 615x415x150mm with wall mounted single lever concealed basin mixture (cartridge size 32mm.) (Premium Range) each 15591.0 25.9.2 Providing and fixing white vitreous china type Anti germ fluoro-polymer coated counter top wash basin Size 600x400x185mm with 15 mm C. P. wall mounted single lever concealed basin mixture. (Premium Range) each 14940.0 341 25.1 25.10.1 White Vetrious China Anti germ Fluoro-Polymer Coated Wash Basin Size 595x435x185mm with Table mounted single lever Tall boy basin mixture, (cartridge size 32mm.) (Premium Range) each 18585.0 25.10.2 White vitreous china type Anti germ fluoro- polymer coated counter top wash basin Size 530x420x140mm with tall boy basin mixture, (cartridge size 32 mm). (Premium Range) each 16785.0 342 25.11 25.11.1 White Vitreous China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm. (Premium Range) each 14544.0 25.11.2 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal size 475X315X715 mm top inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) with 15mm Brass made Pressmatic auto closing open urinal flush valve with wall flange (Decol technology, 400000 operation warranted) complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : each 13336.0 25.11.3 Providing and fixing white vitreous china Flat Back Anti germ Fluoro-Polymer Coated urinal back inlet with fixing accessories (Inbuilt spreaders, Inbuilt Bottle trape and inbuilt ceramic Waste coupling) Size 385X325X635 mm with Concealed sensotronic flushing valve for urinal complete set with installation box with control cock complete including painting of fittings and brakets, cutting and making good the wall and floors wherever required : URS-WHT-13253N & PRS-CHR-073 each 10641.0 343 25.12 25.12.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 340x325x650 mm with sensotronic concealed type flushing valve battery & electrical oprated type (9V transformer) for urinal complete set with installation box with control cock. (Premium Range) each 23927.0 25.12.2 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal size 385x325x635 mm with concealed sensotronic flushing valve for urinal complete set with installation box, (Premium Range) each 20025.0 344 25.13 25.13.1 White Vetrious China Anti germ Fluoro-Polymer Coated Urinal Size 480 X 300X740 mm with 15mm Brass made pressmatic auto closing concealed urinal flush valve with wall flange (Decol technology, 400000 operation warranted). (Premium Range) each 18491.0 345 25.14 346 25.14.1 25.14.2 Providing and fixing white vitreous china flat back Anti germ fluoro-polymer coated Urinal size 475x315x715 mm (Inbuilt spreaders, bottle trap and ceramic waste coupling) with inbuilt sensor battery & electrical oprated type (9V transformer) for flushing. (Premium Range) each 22998.0 347 25.15 348 25.16 349 25.17 350 25.18 351 25.19 352 25.21 353 25.22 354 25.23 355 25.24 356 25.25 357 25.26 358 25.27 359 25.28 360 25.29 361 25.31 362 25.32 363 25.33 364 25.34 365 25.35 366 25.36 367 25.37 368 25.38 369 25.39 370 25.41 371 25.42 372 25.43 373 25.44 374 25.45 375 25.46 376 25.47 377 25.48 378 25.49 379 25.51 380 25.52 381 25.53 382 25.54 383 25.55 384 25.56 385 25.57 386 25.58 387 25.59 388 25.61 389 25.62 390 25.63 vitreous china type Anti germ fluoro-polymer coated wall mounted wash basin with C.I. brackets, C. P. brass single lever basin mixer, 15mm quarter turn angular stop cock, 32 mm C.P. brass waste coupling length 130mm and 32 mm C.P. brass bottle trap size 200x300mm i/c cutting and making good the wall and floors wherever required, all fittings and fixtures etc. complete . (Premium Range) 25.63.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 14729.0 25.63.2 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 570x470x190 mm. (Premium Range) each 15100.0 25.63.3 white Vetrious china Anti germ fluoro-polymer coated wall hung intergrated wash basin size 495x400x365 mm. (Premium Range) each 18490.0 391 25.64 25.64.1 white Vetrious china Anti germ fluoro-polymer coated wall mounted wash basin size 620x480x185 mm. (Premium Range) each 10617.0 Note- Schedule of items includes all the items required for maintainance of buildings regarding A/R, S/R MOW, Deposit & Other Works as per SCHEDULE OF RATES FOR BUILDING WORKS inforce from 01/01/2024, issued by Project Director, Public Works Department (PIU) M.P. Bhopal. Sub Engineer Sub Divisional OfficerSurvey Sub Division.P.W.D. Bhopal Executive EngineerMaintanance Division No.2P.W.D. Bhopal
Contract Date: Apr 23, 2026 Contract Value : 21.93 Lakh
Government Departments No of Bidders 5
Madhya Pradesh View Result →
5.
Public Administrative Department #11300148 AOC
Tender For Construction Of Inspection Banglow, Guest House, Boundary Wall & Garage Near Suklai Head Works Under Extension, Renovation And Modernization Of (Erm), Sukla Irrigation Project Under Pmksy-Aibp For The Year 2021-22. , Construction Of Inspection Banglow, Guest House (Ground Floor). Earth Work : Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. All Kinds Of Soil. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size De Rived From Natural Sources) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Providing And Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 12.5Mm Nominal Size Derived From Natural Sources) , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Pre Construction Anti - Termite Treatment : Diluting And Injecting Chemical Emulsion For Post-Constructional Anti-Termite Treatment (Excluding The Cost Of Chemical Emulsion) : Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration , Brick Work : Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Plinth Protection : Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation Leveling And Dressing And Finishing The Top Smooth. , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow Cum Guest House (First Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Second Floor). Steel Work : Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More , Cement Concrete Work : Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Shuttering & Formwork : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Columns, Pillars, Piers, Abutments, Posts And Struts , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Stairs, (Excluding Landings) Except Spiral-Staircases , Brick Work : Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 (1 Cement :4 Coarse Sand) , Wood Work : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately). Sal Wood , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows, Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. (Note:- Butt Hinges And Necessary Screws Shall Be Paid Separately) Second Class Teak Wood 35 Mm Thick Shutters , Pvc Door Frame : Providing And Fixing Factory Made Pvc Door Frame Made Of Pvc Extruded Sections Of Size 75 Mm X 53 Mm, Having Wall Thickness 2.0 Mm (± 0.2 Mm). Both Verticalssides Of The Frame Reinforced With Pvc Profile Of Cross Section Size 28 Mm X 30 Mm X 2 Mm Thickness (± 0.2 Mm) And 75 Mm X 200 Mm Long, Including Reinforcing Both Ends Of The Top Frame With Pvc Profile. Pvc Door Frame And Pvc Reinforcement Profile To Be Mitred Cut, Jointed And Fusion Welded Together, Including Providing And Fixing 3 Nos Of 125 Mm Long Stainless Steel Hinges To Frame, Fixing The Frame With Jamb With Required Nos & Sizes Of Anchor Dash Fastener, All Complete As Per Manufacturers Specification And Direction Of Engineerin-Charge. , Providing And Fixing 37 Mm Thick Factory Made Pvc Door Shutter, Styles And Rails Made Of Pvc Hollow Section Of Size 100 Mm X 37 Mm With Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Bead On One Side, Styles And Rails Mitered Cut And Joint At The Corners By Means Of 2 Nos Of Plastic Brackets Of Size 75 Mm X 220 Mm At Each Corner And Stainless Steel Screws, Reinforcing The Hinge Side Of Tyle By Inserting Pvc Profile Of Size 28 Mm X 30 Mm, With Wall Thickness 2 Mm ( ± 0.2 Mm). Lockrail Of Size 100 Mm X 37 Mm, Wall Thickness 2 Mm (+ 0.2 Mm) Will Be Fixed To The Vertical Styles. Providing With Pvc Snapfit Beads And Panel Of Size 100 Mm X 20 Mm, And Inserting 2 Nos Tie Bar Of 6 Mm Dia And Fastening With Nuts And Washers Complete, All As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Less Than 12.50 Kg/Sqm) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item): With Float Glass Panes Of 5 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , Tiles Works : Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm , Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Steel Windows By Welding. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Plastering Works : 12 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:4 (1 Cement: 4 Fine Sand) , 20 Mm Cement Plaster Of Mix : 1:4 (1 Cement: 4 Fine Sand) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Roofing : Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 B49grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester To Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : Using Self Drilling/ Self Tapping Screws Complete : Ridges Plain (500 - 600Mm) , Sound Proof : Providing And Fixing Thermal Insulation With Resin Bonded Fibre Glass Wool Conforming To Is: 8183 Having Density 24 Kg/M3, 50 Mm Thick, Wrapped In 200G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held In Position By Criss Crossing Gi Wire Etc. Complete As Per Directions Of Engineer-In-Charge. , 8 Mm Thick Fully Perforated Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Autoclaving Processto Give Stable Crystalline Structure With Minimumcompressive Strength 225 Kg/ Sq. Cm, Bending Strength100 Kg/Sq. Cm , Of Size 595X595 Mm, Having Perforationof Dia. 10 Mm With Minimum Perforated Area 18 % Withnon Woven Tissue On The Back Side, Having An Nrc( Noise Reduction Coefficient) Of 0.85, With 50 Mm Thickrockwool Of 48 Kg /Cum Backing , Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms/Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall/Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C/C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : Fully Perforated Gypsum Plaster Board Of Size 1200 X 2400X12.5 Mm Having Approx. 15 % Perforated Area With Perforation Size And Pattern As Approved By The Engineerin-Charge And As Per Manufacturers Specification, With All 4 Side Tapered And Backed By Acoustical Tissue With Nrc Value Not Less Than 0.60 , Painting : With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacture , With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm Of Approved Brand And Manufacture , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. New Work (Two Or More Coats Applied @ 1.43 Litre/ 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/10 Sqm. , Door Window Fittings : Providing And Fixing Aluminium Sliding Door Bolts, Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868), Transparent Or Dyed To Required Colour Or Shade, With Nuts And Screws Etc. Complete : 300Mm X 16Mm , Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 300Mm X 10Mm , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125Mm , Providing And Fixing Ptmt Butt Hinges With Necessary Screws Etc. Complete. 75X60x10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms , Construction Of Inspection Banglow, Guest House (Inetrnal Electrification) Sub Head -I (Wiring) Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. A) Group A , Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , Wiring For Light/ Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. 3 X 1.5 Sq. Mm , 6 X 1.5 Sq. Mm , 6 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 20 Mm , 25 Mm , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3Pin 5/6 Socket Outlet , Sub Head - Ii (Mcb & Dbs ) Supplying And Fixin G Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator)8 Way, Double Door , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 215 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 4 Way (4 + 12), Double Door , Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, C Curve, Miniature Circuit Bre Aker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40/63 A Tp , Sub Head-Iii (Fan,Fittings And Fixtures) Supplying, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee Five Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc Motor) Not Less Than 32 W, Class Of Insulation B, 3 Nos Blade, 30 Cm Long Down Road, 2 Nos Of Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85 Air Delivery Minimum 215Cmm , 350 Rpm (Tolerance As Per Is:374-2019), Thd Less Than 10% Remote Or Electronic Regulator For Speed Control And All Remaining Accessories I/C Safety Pin, Nut Bolts , Washer, Temperature Rise=75 Degree C(Max. ), Insulation Resistance More Than 2Mega Ohm, Suitable For 230V, 50 Hz Ac Supply, Earthing Etc. Complete As Required. , Supplying, Installation Of Exhaust Fan Sweep Not Less Than 300 Mm In The Existing Opening, And Made Of Aluminium Die-Cast Motor Body, Front Protection Guard, Low Noise Operation, Robust Metal Body,Double Ball Bearing,Anti Dust,High Speed(Minimum 1350 Rpm) & High Air Delivery(Minimum 1000 Cmh) Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. , Supplying,Installation, Testing And Commissioning Of Surface Mounted Square/Round Shape Led Downlighter Having Suitable Housing Lumen Efficacy = 100Lm/Watt, System Lumen Output = 1200 Lm, Cri = 80, Power Factor = 0.9 Having Suitable Diffuser And Cct In Between 4000K To 6500 K (I/C Both Limits) Complete With All Accessories Etc. Directly On Ceiling/Wall Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. , Sub Head-Iv (Service Connection) Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. Upto 35 Sq. Mm , Above 35 Sq. Mm And Upto 95 Sq. Mm , Supplying Of One Number Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade With Isi Marked (Is 7098 (Part - I) / 1988 With Amendment Up To Date) Following Sizes. A) 3 ½ X 35 Sq.Mm , B) 3 ½ X 95 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. A) 3.5 X 35 Sqmm ( 32 Mm ) , B) 3½ X 95 Sq. Mm (45Mm) , Supplying And Fixing Of Light Class G.I. Pipe Of 80 Mm Dia. (Nominal) 3 Metres Length Along The Pole For Protection Of Under Ground Cable As Required. , Sub-Head -V( Lighting Conductor And Earthing ) Providing And Fixing Of Lightning Conductor Finial, Made Of 25 Mm Dia 300 Mm Long, G.I. Tube, Having Single Prong At Top, With 85 Mm Dia 6 Mm Thick G.I. Base Plate Including Holes Etc. Complete As Required. , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Horizontal Run) , Providing And Fixing G.I. Tape 20 Mm X 3 Mm Thick On Parapet Or Surface Of Wall For Lightning Conductor Complete As Required. (For Vertical Run) , Providing And Fixing Testing Joint, Made Of 20 Mm X 3 Mm Thick G.I. Strip, 125 Mm Long, With 4 Nos. Of G.I. Bolts, Nuts, Chuck Nuts And Spring Washers Etc. Complete As Required , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Required , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required. , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required , Providing And Laying G.I. Tape 32 Mm X 6 Mm From Earth Electrode Directly In Ground As Required. , Sub Head-Vii (Air Condition) Supplying, Installation, Testing And Commissioning Of Suitable Tr Capacity 5 Star Rating With Eer Not Less Than 4.3 , Split Type Inverter Air Conditioning Units Suitable For Indoor Unit To Be Fixed On The Wall Having Minimum Cooling Capacity 5400 Kcal/Hr Suitable For Single Phase Ac Supply Complete With Outdoor Unit Having Copper Condenser Coil,Suitable Clamp/Bracket For Fixing Outdoor Unit, Inter Connection With Suitable Copper Pipe Etc. Complete As Required. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supplying , Installation, Testing And Commissioning Of Automatic Voltage Stabilizer Of Capacity 5 Kva For Air Conditioner With 130-240 Volts Range For Operation Of Air Conditioner Complete With Testing Trail Run Etc Complete As Reqd. , Supply, Installation Testing & Commissioning Of Rigid Upvc Piping Complete With Fittings, Supports As Per Specifications And Duly Insulated With 6 Mm Thick Closed Cell Nitrile Rubber Insulation. A) 25 Mm Dia ( With 6 Mm Nitrile Rubber Insulation) , Construction Of Inspection Banglow, Guest House (For Sanitary & Water Supply) Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require: White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is:13983 With C.I. Brackets And Stainless Steel Plug 40 Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required : Kitchen Sink With Drain Board 510X1040 Mm Bowl Depth 250 Mm , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Semi Rigid Pipe 40 Mm Dia , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing Toilet Paper Holder : Vitreous China , Providing And Fixing Soil, Waste And Vent Pipes : 100 Mm Dia Sand Cast Iron S&S Pipe As Per Is: 1729 , Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors : 100 Mm Inlet And 100 Mm Outlet Sand Cast Iron S&S As Per Is: 3989 , Cutting Chases In Brick Masonry Walls For Following Diameter Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Making Good The Same With Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 12.5 Mm Nominal Size), Including Necessary Plaster And Pointing In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) : 100 Mm Dia , Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Providing And Fixing Ptmt Towel Ring Trapezoidal Shape 215 Mm Long, 200 Mm Wide With Minimum Distances Of 37 Mm From Wall Face With Concealed Fittings Arrangement Of Approved Quality And Colour, Weighing Not Less Than 88 Gms. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms , Providing And Fixing Brass Bib Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Brass Stop Cock Of Approved Quality : 20 Mm Nominal Bor , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 15 Mm Dia Nominal Outer Dia Pipes , 20 Mm Dia Nominal Outer Dia Pipes , 25 Mm Dia Nominal Outer Dia Pipes , 32 Mm Dia Nominal Outer Dia Pipes , 40 Mm Dia Nominal Outer Dia Pipes , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc Internal Work - Exposed On Wall 15 Mm Dia Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. Internal Work - Exposed On Wall 20 Mm Dia Nominal Bore , 32 Mm Dia Nominal Bore Metre , 40 Mm Dia Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 20 To 40 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) 20 Mm Nominal Bore , 32 Mm Nominal Bore , 40 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 15 Mm Nominal Bore , 20 Mm Nominal Bore , 25 Mm Nominal Bore , Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality (Screwed End) : 40 Mm Nominal Bore Horizontal , Vertical , Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore , 20 Mm Nominal Bore , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Tube Well Boring With 100 Mm Diameter Casing Pipe For Hand Pump / Tubewell, In All Soils Except Ordinary Hard Rocks Requiring Blasting, Including Removing The Casing Pipe After The Hand Pump / Tube Well Is Lowered And Tested : Up To 6 Metres Depth , Beyond 6 M And Up To 12 M Depth , Beyond 12 M And Up To Required Depth , Providing And Placing In Position Filters Of 40 Mm Diameter G.I. Pipe With Brass Strainer Of Approved Quality. , Providing And Placing In Position Hand Pump Of Approved Quality For 40 Mm Diameter G.I. Pipe Complete With All Accessories. , Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete (New Work) : 50 Mm Nominal Bore , Providing And Fixing Square-Mouth S.W. Gully Trap Class Sp-1 Complete With C.I. Grating Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size (Inside) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design: 150 X 100 Mm Size P Type With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Constructing Brick Masonry Manhole In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand ) With Reinforced Cement Concrete Top Slab With 1:1.5:3 Mix (1 Cement : 1.5 Coarse Sand (Zone-Iii) : 3 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix (1 Cement : 4 Coarse Sand (Zone-Iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size), Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610 Mm Internal Dimensions, Total Weight Of Cover And Frame To Be Not Less Than 38 Kg (Weight Of Cover 23 Kg And Weight Of Frame 15 Kg) : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Reducing Socket, Bend, Tee, Etc. , Construction Of Septic Tank. (50 Users) Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Suspended Floors, Roofs, Landings, Balconies And Access Platform , Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , Cement Plaster Skirting Up To 30 Cm Height, With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Finished With A Floating Coat Of Neat Cement. , Retaining Wall Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. , Providing And Fixing Stainless Steel ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , Dismentling Existing A-Type Building Demolishing Reinforced Cement Concrete Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles Above 25 Mm And Up To 40 Mm , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Wood Work In Frames, Trusses, Purlins And Rafters Up To 10 Metres Span And 5 Metres Height Including Stacking The Material Within 50 Metres Lead : Of Sectional Area 40 Square Centimetres And Above , Dismantling Roofing Including Ridges, Hips, Valleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of G.S. Sheet , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Boundary Wall With Fencing). Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. , Dry Brick Pitching Half Brick Thick In Drains Including Supply Of Bricks And Preparing The Surface Complete : , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level : , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For , Lintels, Beams, Plinth Beams, Girders, Bressumers And , Columns, Pillars, Piers, Abutments, Posts And Struts , Brick Work With Common Burnt Clay Modular Bricks Of Class Designation 7.5 In Foundation And Plinth In : , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : , 20 Mm Cement Plaster Of Mix : , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer , Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives. , Fencing With Reinforced Cement Concrete Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post (Cost Of Reinforced Cement Concrete Posts, Struts, Earth Work And Concrete To Be Paid For Separately) :- Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. , Land Development Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , O.H. Tank Not Found!!! , Solar Street Light Godox S60 Led Focusing Light, Outdoor & Indoor , Gate Pillarlight For Home Outdoor Garden Post Decorative Lamp , Dg Set , Audio Visual Systems Projector (Sony) , Motorised Screen And Accessories (6Ft / 8 Ft) , Digital Podium All-In-One System , Chairman Unit , Delegate Unit , Amplifier 80 Watt , Microphones , Ceiling Mount Speaker ( 6 Watt) , Wire & Lane Cabling For Speaker , Projector & Amplifier Hdmi Wire Connector Wiring Set , Installation, Testing And Commissioning Charges And Configuration Of The System , M.I. 64 -T.V. 4 Nos. @ Rs. 75000/- Per Nos. , Cctv With Motion Sensor And Sound Recorder Including Supplying & Fitting Fixing (Philips Hsp 3800) , Furniture & Fixture Sofa Set A/ Waiting Hall , B/ Executive Guest Room , C/ Suite Room , Executive Table A/ Executive Guest Room , B/ Suite Room , Executive Chair , Bed A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Matress A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Chair A/ Guest Room , B/ Staff Room , C/ Suite Room I)Type-I , Ii)Type-Ii , D/ Security Room , Bed Sheet A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Pillow A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Blanket A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Mosquito Net A/ Guest Room , B/ Staff Room , C/ Suite Room , D/ Security Room , Bath Towel , Hand Towel , Kitchen Utensil A/ Gas Stove , B/ Pressure Cooker , B/ Cookware Set , C/ Dinner Set , D/ Cup Plate Set , E/ Cutlery Set , F/ Mixture Grinder , G/ Electric Kattle , H/ Microwave Oven , I/ Container , Conference Table , Conference Chair (Elentra-112 Steel Frame Fixed Chair)
Contract Date: Jun 16, 2026 Contract Value : 4.10 Crore
Government Departments No of Bidders 2
6.
Public Administrative Department #11290947 Technical Bid
Tender for Cartage Of Malva, Silt, Sludge Kankar And Other Disposable Organic Material Etc. All Complete With Labour T&P Including Cartage Of 8 Km. (Chapter No.3 Si.No.8) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (1 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (2 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Cartage Of Earth/Malva Up To 90 Meters By Head Load (3 Chain Only) Including Loading & Unloading Etc. All Complete. (3-Chapter Sr..No.234) , Earth Work In Filling In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 8Km. Form The Foundation Trenches Including Royalty@ 9.00 Per Cum. (Chapter No.4 Pwd.Sch.-253(A)+ Cptr No. 3 1 To 8 Km.) , Earth Work In Excavation In Foundation In Ordinary Soil (Loam, Clay Or Sand) Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Earth Work In Excavation In Foundation In Ordinary Soil Mixed With Moorum Shingle Kankar Requiring The Use Of Special Tools And Plants Such A Pick Axes Subbals Etc. Including, Lift Up To 1.50 M And Lead Up To 30M And Including Filling Watering And Ramming Of Excavated The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-In-Charge Up To A Distance Of 30 M Form The Foundation Trenches. (Rate Including Royalty Of Earth Also) (4-Chapter Si.No.1) , Extra For Earth Work In Embankment Mechanically Compacted To 98% Proctor Density Ln Ordinary Soil, Excavation To Be Done Form Of Regular Pits Not Exceeding 0.5Mtr In Depth And Work In Embankment To Be In 20Cm Layer Including Ramming And Dressing Pulverization Surfacing Including Supply Of Labour, T&P, Roller And Water Sprinkle , Back Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth: Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50M And Lift Upto 1.5 M Incl. Cost Of All Labor Complete As Per Specifications , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 1.50M To 3M. , Supply & Fixing 3.5Kg And Or As Specified By The Manufacture, Harderner In Trexim Concrete Per Sqm. , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 3.00M To 4.50M. , Cleaning Jungles Including Uprooting Of Trunk Vegetation Grass, Bushes, Wood Trees And Sapling Of Girth Upto 30Cm Measured At A Height Of 1 Meter Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 Meters Out Side The Periphery Of Area Cleared. , Removal Of Silt For Nala/Nali In Liquid Mud Or Faul Position With Special T&P Including Lead 30M And Lift Up To 3.00M Etc. All Complete. (As Per Attached Sanctioned Rate Analysis) , Earth Work In Excavation In Ordinary Soil With Manually/Hydrolic Excavater In Foundation/Trench Or Drains. (A) Lift Up 4.50M To 6.00M. , Earth Work In Cutting Or In Embankment In Ordinary Soil Excavation To Be In The Form Of A Regular Pits Not Exceeding 0.50M In Depth And Earth Work In Embankment To Be In 20Cm Layers Including Ramming And Dressing The Surface To Required Lavels And Slops And Also Including 1.5 M Lift And 30 M Lead. The Earth In Form Of Cutting (B) To Be Used As Spoil Banks Within 50M Distance As Directed By The Engineer-In-Charge Etc. All Complete. (4-Chapter Si.No.3) , Sand Filling In Plinth Including Supply Of Necessary Quality Of Local Sand From A Distance Not Exceeding 8 Kms From The Site Of Work And Including Watering Dressing Etc.Required For Proper Completion Of Work (Chapter No.4 Si.No.6 ) , Providing And Laying Cement Concrete In 1:5:10 (1 Cement :5 Fine Sand 10 Stone Ballast 40 Mm Gauges) And Curing Complete, Including Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.1) , Providing And Laying Cement Concrete In 1:4:8 (1 Cement:4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors (5-Chapter Sr.No.2) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand :6 Gladed Stone Aggregate 40 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work In Foundation And Floors. (5-Chapter Sr.No.3) , Providing And Laying Cement Concrete In 1:3:6 (1 Cement: 3 Coarse Sand:6 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. In Foundation And Floors. (5-Chapter Sr.No.5) , Providing And Laying Cement Concrete In 1:2:4 (1 Cement: 2 Coarse Sand :4 Graded Stone Aggregate 40 Mm Noffrinal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors..(5-Chapter Sr.No.6 Si.No..4.1.3) , Providing And Laying Cement Concrete In 1:1.5:3 (1Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) And Curing Complete, Lncluding Cost Of Form Work. Ln Foundation And Floors. (5-Chapter Sr.No.7) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement -All Work Up To Plinth Level: 1:2:4 (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete , Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Up To Plinth Leuel:1:2:4 In Raft Foundation (1Cement: 2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Including The Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement - All Work Trp To Plinth Level : 1:1.5:3 (1 Cement:1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) Ch-S Si No- 5,1.2 , Reinforced Cement Concrete Work Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete,Slab Including The Cost Of Centering, Shutterang, Finishing And Excluding Reinforcement - Above Plinth Level Upto Fifth Floor Lable : 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level , Reinforced Cement Concrete Work In Walls/Columns (Any Thickness), Including Attachedpilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abulments, Posts And Struts Etc. Including Cost Of Centering, Shuttering, Finishing And Excluding Reinforcement:1:1.5:3 (1 Cement: 1.5 Coarse Sand ;3 Graded Stone Aggregate 20 Mm Nominal Size) Above Plinth Level Upto Fifth (V) Floor Lable , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Balconies, Shelves, Chajjas, Bands, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Including The Cost Of Centering, Shuttering, Finishing Exlcuding Reinforcement, With 1:1.5:3 In Heavier Beam (1 Cement: 1.5 Coarse Sand(Zone-Lll) : 3 Graded Stone). , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Work Up To Plinth Level (5-Chapter S.I. No.-16) , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying And Including The Cost Of Centering, Shuttering, Finishing But Excluding Reinforcement, Including Admixtures In Recommended Proporlions As Per Ls: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable / Recoverable Separately).All Works Above Plinth Level Upto Floor V Level (5-Chapter S.I. No.-16) , Class-150 (Non Modular) Brick Work In 1:6 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.. ( Chapter No. 06 Sr.No. 1) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Foundation And Plinth Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapter No. 06 Sr.No. 2) , Class-150 (Non Modular) Brick Work In 1 :4 Cement And Fine Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Only 80Mm Thick Wall). (Chapter No. 06 Sr.No.3) , Class-150 (Non Modula0 Brick Work In L:3 Cement And Coarse Sand Mortar In Foundation And Plinth Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work (Chapter No. 06 Sr.No.4) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. ( Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand, Mortar In Super Structrure Including Supply Of All Materials, Labor And Tools And Plants, Etc. Required For Proper Completion Of The Work. (Chapte No. 06 S.I. No. 2+5) , Class-150 Brick Work In 1:4 Cement And Coarse Sand Mortor In Super Structure Above Plinth Level Upto Floor Five Level For Wall Thickness More Than 12Cm. Including Supply Of All Material, Labour And Tools And Plants Etc. All Complete. {Chapter No.6 Si.No.2+6} , Add Extra To Ltem No. 1 To 4 Above For Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 12Cm And Less. (Chapte No. 06 S.I. No. 2+4) , Add Extra To Ltem No. 1 To 4 Above But In Super Structure Above Plinth Level Upto Floor Five Level Including Necessary Cutting And Moulding Of Brick Work As Required And Also Including Honey Combed Brick Work In Thickness Of Wall 8Cm And Below. (Chapte No. 06 S.I. No. 2+4) , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.1} , Providing And Laying Damp-Proof Course 25 Mm Thick With Cement Concrete 1:2.4 (1 Cement : 2 Coarse Sand :4 Graded Stone Aggregate 12.5 Mm Nominal Size). {Chapter No.07 Si.No.2} , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Vg-10 Of Approved Quality Using 1.7K9 Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Piece Of Cloth Lightly Soaked In Kerosene Oil.. {Chapter No.07 Si.No.3} , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (A) 35Mm Thick. (Chapter No.9 Si.No.1-9.21.1) , Providing And Fixing Lsl Marked Flush Door Shutters Conforming Lo Ls : 2202 (Part L) Decorative Type, Core Of Block Board Construction With Frame Of 1 St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.Including Lsl Marked Stainless Steel Butt Hinges With Necessary Screws. (Excluding Cost Of Flttings). (2) 30Mm Thick. (Chapter No.9 Si.No.1-9.21.2) , Providing & Fixing 1.00 Mm Thick Decorative High Pressure Laminated Sheet Of Plain/Wood Grain In Gloss/Matt/Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Uality Conforming To Is : 2046 Type S, Including Cost Of Aadhesive Of Approved Quality. , Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styless And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shal Be Flat And 20 Mm Shalll Be Tapered In 45 Degree Angle On Both Sides Forming Styless And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail And Lock Rails Shall Be Top, Bottom And Lock Rails Shall Be Provided Both Sides Of The Panel. 10 Mm (5 Mm X 2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded/Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interrior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing.30 Mm Thick Pre Laminated Pvc Door Shutters , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Ls: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Ls: 733 And Ls: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdiv] Rubbe, Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Requlred Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately). Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item): With Float Glass Panes Of 4.0 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber/ Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 5.5 Mm Thickness , Provdmg And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per (Cost Of Aluminium Snap Bead:Ng Shall Be Paid In Basic Item):With Float Glass Panes Of 8.0 Mm Thickness , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315 , Having Brand Logo Embossed On The Body/ Plate With Double Spring Mechanism And Door Weight Upto 125 Kg, For Doors Including Cost Of Cutting Floors ,Embeding In Floors As Required And Making Good The Same Matching To The Existing Floor . Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Entineer-In-Charge. With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. , Providing And Tixing Factory Made Upvc White Colour Casement/ Casement Cum Frxed Glazed Door Comprising Of Upvc Multi-L Chambered Frame. Sash And Mullion (Where Ever Required) Extrlcled Profiles Dl,Ly Reinforced With 1.60 T 0 2 Mm Thick I Galvalized Mild Steel Section Made From Roll Forming Process Of Iequrred Length {Shape & Size According To Upvc Profile), I Ldvc Extruded Glazing Beads Of Appropriate Dimension. Epdi\/L Gasket. Znc Alloy (White Powder Coated) 3D Hrnges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Rnulti Point Locking Having Transmission Gear, Cylinder With Keeps And One Sicle Key, G.L Fasteners 100 X I Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Weldecl Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. Afier Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approvecl Quality, All Complete As Per Approved Drawing & Cllrection Of Engineer-In-Charge. (Single I Double Glass Panes And Sllicon Sealent Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dlrnension I.E. In Depth & Width Of Profile Shall Be Acceptable Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Rm & Sasn 67 X 1 10 Mm Both Having Wall Thickness Of 2.3 I 0.2 ^Rr Ancl Single Glazing Bead / Double Glazing Bead Of Lappopiate D.Mersion. (Area Of Door Upto L2 00 Sqm). , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Providng And Fixing Fictory Made Solid Foam Upvc Profile For Kitchen Cabinet Fram E (45 X 20 Mm) Of Approved Shade, Quality Ancl Make. The Profile Shall Be Laminated On Both Sides, Made From Rigid Foam Sheets (Single Extruded) Having Density 600 Kg/Cum And The Exposed Edges Sealed With Pvc Edge Beading Of Same Shade And Colour. The Frame Shall Be Fire Retardent With Necessary Screw Holding Capacity. Frame Shall Be Fixed To Wall Using Expendable Fastner With Necesary Stainless Steel Screws, All Complete As Per Direction Of Engineer-In- Charge , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Structural Steel Work In Single Section, Fixed With Or Withoul Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Steel Work Welded In Built Up Sections/ Framed Work, Including Cutting, Hoisting,Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required Heavy Size Such As Trusses Built , Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Apptying A Priming Coat Of Approved Steel Primer.(Chapter No.10 Si.No.4-10.3) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pjpe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\4.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover (Upto 10.00 Sqm).(Chapter No.10 Si.No.4-10.5) , Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Ls: 4454 - Part 1 And L\Il.S. Top Cover Of Required Thickness For Rolling Shutters.. 80X,1.25 Mm M.S. Laths With 1 .25 Mm Thick Top Cover Extra For Providing Mechanical Device Chain And Crank Operation For Operating Rolling Shutters. Exceeding 10.00 Sqm And Upto 16.80 Sqm/Above In The Area , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc, Complete. Hot Finished Welded Type Tubes , Supply And Fixing Stainless Steel (Grade 304) Ralling Made Of Hollow Tubes, Channels, Plates Etc. Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Steel Nuts And Bolts Complete. I/C Fixing The Ralling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts Fasteners Etc.). (Chapter No.10 Si. No. 14 New) , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Galvanised M.S. Wire Gauze With 0.63 Mm Dia Wire And 1 .4 Mm Aperture On Both Sides , Providing & Fixing Fly Proof Wire Gauze To Windows, Clerestory Windows & Doors With M.S. Flat 15X3 Mm And Nuts & Bolts Complete Stainless Steel (Grade 304) Wire Gauze Of 0.5 Mm Dia Wire And 1.4 Mm Aperture On Both Sides , Painting Top Of Roofs With Bitumen Of Approved Quality @ 17Kg Per 10 Sqm Impregasted With A Cost Of Coarse Sand At 60 Codm Per 10 Sgm, Including Cleaning The Slab Surface With Keroseme Oil Complete : With Residual Type Petroleum Bitmen Of Grade Vg-10 , Providing And Laying Integral Cement Based Water Proofing Itreatment Including Preparation Of Surface As Required For Itreatment Of Roofs, Balconies, Terraces Etc Consisting Of Lfollowing Operations: (A) Applying A Slurry Coat Of Neat Cement Lusing 2.75 Kg/Sqm Of Cement Admixed With Water Proofing Lcompound Conforming To Ls. 2645 And Approved By I E Ng Ineer-In-Charge Over The Reinforced Cement Concrete Slab Including Adjoining Walls Lupto 300 Mm Height Including Cleaning The Surface Before Llreatment. B) Laying Brick Bats With Mortar Using Broken Bricks/Brick Bats 125 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 (1 L Cement : 5 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 (1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Ofjunctions Of Walls And Slabs. (C) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg/ Sqm Of Cement Admixed With Water Proofing Compound Conforming To Lb : 2645 And Approved By Engineer-In-Charge (D) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix L:4 (1 Cement :4 Coarse Sand) Admixed With Water Proofing Compound Conforming To Ls:2645 And Approved By Engineer-In-Charge Includlng Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finjshing The Surface With Lrowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep (E) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge :Wth Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65Mm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 1.00 Mm Thick With Zinc Coating Not Less Than 275 Gm/Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 80 Mm Thick With Zinc Coating Not Less Than 275 Gm/ Sqm , Providing Corrugated G.S. Sheet Roofing Including Vertical /Curved Surface Fixed Wit Polymer Coated J Or L Hooks, Bolts And Nuts B Mm Diameter With Bitumen And G.L. Limpet Washers Or With G.L. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/Vertical Or Curved Surfaces), Excluding The Cost Of Purlins,Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/ M , Providing And Laying Six Courses Water Proofing Teatment With Bitumen Felt Over, Roofs Consisting Of First, Third And Llfth Course Of Blown Bitumen 85/25 Or 9O/15 Conforming To Ls : 702 Applied Hot @ 1.45, L.2O And 1.45 Kg Per Square Metre Of Area Respitively, Second And Fourth Courses Of Roofing Felt Lype 3 Grade I Conforming To Ls : 1322 (Hessian Based Self Flnished ;Itumen Felt) , Sixth And Final Course Of Stone Grit 6 Mm And Down Size Or Pea Sized Gravel Spread At 6 Cubic Decimeter Per Sqm Iniluding Preparation Of Surface But Excluding Grading, Complete. , 10 Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa @ 35 Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Flat Tile Bricks, Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finished Neat: With Common Burnt Clay F.P.S.(Non Modular) Brick Tile Of Class Designation 10 , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineerin-Charge) 0 50 Mm (+ 0.05 %) Total Coated Hickness With Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Icrons Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge, The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roollng Accessories 0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Ls: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete :Ridges Plain (500 - 600Mm) , Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Ls: 12823 Grade Ltype Ll, In Anelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , Providing And Fixing 12 Mm Thick Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured). Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick. I\4Arine Plywood Conforming To Ls: 710 , Providing And Fixing Tiled False Ceiling Of Specilled Materials Of Size 595X595 Mm In Lrue Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanlzed @ 120 Grams/ Sqtn, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel Lo Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Iight Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gl Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gl Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T- Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gl Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G Lsheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns (Minimum), Including Factory Painted After Bending , Providing And Fixing False Ceiling At All Heights With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595mm Of Approved Texture, Design And Patterns Having Nrc (Noise Reduction Coefficient) Of 0.50 (Minimum) As Per Ls 8225:1987, Light Reflectance Of 85%(Minimum). Non Combustible As Per Bs:476 (Part-4), Fire Performance As Per Bsi476 (Part 6 &7), Humidity Resistance Of 100%, Thermal Conductivity 0.043 W/M K As Per Astm 518:1991,In True Horizontal Level Suspended On Inter- Locking Metal T-Grid Of Hot Dipped Galvanised Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 24X38 Mm Of Length 3000 Mm, Cross - T Of Size 24X32 Mm Of Length 1200 Mm And Secondary Intermediate Cross-T Of Size 24X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E. 50 Mm Long, I Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x25x2 Mm. Galvanised Iron Perimeter Wall Angle Of Size 24X24x0.40 Mm Ol Length 3000 Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 460 Mm Center To Center And 40 Mm Long Dry Wall S.S Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-Incharge. With 15 Mm Thick Tegular Edged Light Weight Calcium Silicate False Ceiling Tiles. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of L:6 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Flool Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceedlng 80Mm. Ln Girth And Finished Even And Smooth. , 12Mm Cement Plaster With Cement Mortar In Proportion Of 1:4 Cement & Fine Sand (Not Less Than In 1.25 Fm) Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:3 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 15Mm Cement Plaster With Cemeni Mortar In Proportion Of 1:4 Cement &.Coarse Sand Of Single Coat For Exterior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding 80Mm. Ln Girth And Finished Even And Smooth. , 20 Mm Cement Plaster 1:3 (L Cement:3 Coarse Sand) Linished With A Floating Coat Of Neat Cement. , 20Mm Cement Plaster With Cement Mortar In Proportion Of L:4 Cement & Coarse Sand Of Single Coat For Interior Plastering Upto Floor Two Level Including Internal Rounded Angles Chamfers, And Rounded Angles Not Exceeding Bomm. Ln Girth And Finished Even And Smooth , 6Mm Thick Celling Plaster 1:3 (1 Cement :3 Fine Sand) Cement & Fine Sand In F.M Not Less Than 1.25, 1:3 Including Chipping Of Reinforced Cement Concrete Surface Before Celing Plaster. The Cost Of Including At Material, Labor T&P And Scafolding Etc Complete. (Chapter No.13 Si.No.13) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Morlar1:4 (1 Cement: 4 Coarse Sand) , Supply/Fixing Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement: 4 Coarse Sand). Including 50Mm Thick Base With Concrete 1:4Rb Complete As Per E/L , Marble Tiles Stone Slabs 18 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With : Marble White Dhungriquality , Marble Stone Flooring With 20 Mm Thick Marble Stone, As Per Sample Of Marble Approved By Engineer-In-Charge, Over 20 Mm (Average) Thick Base Of Coment Mattar 1:4 (1 Cement: 4 Coarse Sand) Lald And Jointed Wlth Grey Cement Slurry, Including Rubbing And Polishing Complete With: White Alebeta White Stone , Kota Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1: 4 (1 Cement: 4 Coarse Sand) : 25 Mm Thick , Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , 40 Mm Thick Fine Dressed Stone Flooring Over 20 Mm (Average) Thick Base Of Cement Moftar 1:5 (L Cement: 5 Coarse Sand)With Joints Finished Flush.Red Sand Stone , Prividing & Laying Ceramic Non Skid Floor Tiles Of Size 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming Tq Ls : 15622 Of Approved Make In Colours Such As White, Lvory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/Sqm Including Pointing The Ioints With White Cement And Matching Pigment Etc., Complete. , Providing & Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming To Ls : 15622 (Thickness To Be Specified By The Manufacturer )Of Approved Make In Atl Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-Incharge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Morta|L:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 33Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles 500X500mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providing And Laying Vitrified Tiles 600X600mm Size (Thickness 10Mm), With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand Manufacture, In Desired Colours And Shades, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, Including Grouting Of Joints. Including 75Mm Thick Base With Concrte 1:4:8 Complete As Per E/I Etc. All Complete. (Chapter No.14 Sr.No.20) , Providlng And Laying Polished Granite Jet Black Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.{Chapter No.14 Si.No.27} , Stone Work (Machine Cut Edges) For Wall Llning Etc. (Veneer Work) Upto10 Metre Height, Backing Filled With A Grout Of Avercge 12 Mm Thick Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Polnting In White Cement Mortar 1:2 (1 White Cement R 2 Stone Dust) Wlth An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Plns Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Flne Dressed With Rough Backing. 30 Mm Thick , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. Including Curing The Cost Of All Material, Labour, T&P Etc. Complete. (Chapter No.15 Si.No.1) , Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Ofwork. , Finishing Walls With Water Proofing Cement Paint Of Required Shade : New Work (Two Or More Coats Applied @ 3.84 Kg/10 Sqm) Supply Of All Labour Material And T&P Requlred For Proper Completion Of Work. , Finishing Walls With Textured Exterior Paint Of Required Shade New Work (Two Or More Coats Applied @ 328 Ll Lo Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20K9/10 Sqm Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade ; New Work (Two Or More Coat Applied @ 1.67 Llth) Sqm Over And Including Priming Coat Ofexterior Primer Applied @ 2 20 Kg/10 Sqm) Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/L0 Sqm Over An Under Coat Of Primer Applled @ O.B0 Ltr/10 Sqm Of Approved Brand And Manufacture. Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Painting Wood Work With Deluxe Multi Surface Paint Of Required Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @0.75 Ltr/10 Sqm Of Approved Brand And Manufacturb Supply Of All Labour Material And T&P Required For Proper Completion Of Work , Paint Of The Two Coat Over Primer Coat Wood Surface And Etc. All Complete.(15-Chapter Si.No.8+10+11) , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Upto 10 Cm In Width , Applying Priming Coat: With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work (Hard And Soft Wood) Including Cost Of All Materials, Labour T&P Etc Required For Proper Completion Of Work , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats On New Work Includlng Cost Of All Materials, Labour T&P Etc. Required For Proper Completion Of Work Wood And Steel , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade : Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Supply Of All Labour Material And T&P Required For Proper Completion Of Work. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..One Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour..Two Coat Including The Cost Of All Material, Labour, T&P Etc Complete. , Removing Dry Or Oil Bound Distemper, Water Proofing Cement Paint And The Like By Scrapping, Sand Papering And Preparing The Sudace Smooth Including Necessary Repairs To Scratches Etc. Complete. , Distempering With Lst Quality Acrylic Distember (Ready Mix) Having Voc Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture To Give An Even Shade:Old Work (One Or More Coats) , White Washing Wth Lime On Undecorated Wall Surface (One Coat) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , White Washing Wth Lime On Undecorated Wall Surface (Three Or More Coats) To Give An Even Shade Including Thoroughly Brooming The Surface To Remove All Dirt, Dust Mortar Drop And Loose Scales Of Lime Wash And Other Foreign Matter. , Colour Washing Such As Green, Blue And Other Coloures Or Buff To Give An Even Shade New Work Colour Washing (Two Coats) With A Base Coat Of White Washing With Limes Including Cost Of All T&P Other Complete Work. , Removing White Or Colour Wash By Scrapping And Sand Papering And Pteparing The Surface Smooth Including Necessary Repairs To Scratches Etc Complete , Demolishing Cement Concrete Manually Including Disposal Of Materialwithin 50 Metres Lead , Dismantling Reinforced Cement Concrete Or Reinforced Brick Work Including Stacking Of Materials As Directed By E/Ic With In A Distance Of 60 Meters (200 Feet). (17-Chapter Pwd. No.694) , Demolishing R.B. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-Incharqe. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge In Cement Mortar. (17-Chapter Si.No.6) , Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Eng;Neer-In-Charge : Ln Lime Mortar , Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead Of Area 3 Sq. Metres And Below , Dismantling Steel Work In Single Sections Including Dismembering And Stacking Within 50 Metres Lead In: R.S. Joists , Dismantling Stone Slab Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead. (17-Chapter Si.No.16) , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Wlthin 50 Metres Lead. , Dismantling Of Old Interlocking Tiles Pavement Including Staking Of Serviceable Material And Disposal Of Unserviceable Material Within Lead Of 50M As Per Direction Of Engineer In Charge. (Ns) , Random Rubble Masonry 1:6 (1 Cement: 6 Coarse Sand), With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size).Upto Plinth Level With , Random Rubble Masonry 1:6 (1 Cement : 6 Coarse Sand), With Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Leveling Up With Cement Concrete 1:6:12 (L Cement:6 Coarse Sand:12 Graded Stone Aggregaie 20 Mm Nominal Size) At Window Sills, Ceiling Level And The Like , 30 Mm Red Sand Stone Sun-Shade (Chisel-Dressed) Supported On Red Sand Stone Brackets, Fixed In Walls With Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Including Finishing Complete. , Providing And Fixing Red Sand Stone Jali 40 Mm Thick Throughout In Cement Mortar 1R3 (1 Cement : 3 Coarse Sand), Including Pointing In White Cement Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment, Matching The Stone Shade, Jali Slab Without Any Chamfers Etc , Stone Work (Machine Cut Edges) For Wall Lining Etc. (Veneer Work) Upto 10 Metre Height, Backing Filled With A Grout Of Average 12 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Pointing In White Cement Mortar 1:2 (1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade: (To Be Secured To The Backing And The Sides By Means Of Cramps And Pins Which Shall Be Paid For Separately) Red Sand Stone - Exposed Face Fine Dressed With Rough Backing. 30 Mm Thick (Chapter No.18 Si.No.7) , Supply And Fixing 500 Liter Pvc. Sintex Water Tank Etc. All Complete. (19-Chapter Sr.No.2(C)) , Laying Brick Soling Layer On Prepared Sub-Grade With Brick On End Edging According To Lines, Graded And Cross-Section Shown On The Drawing Filling Joints With Sand And Earth, Spreading 25 Mm Thick Layer Of Earth Over Brick Soling, Watering And Rolliing The Same With Three Wheel Road Roller 80-100 Kn As Per Technical Specification Clause 412 , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Providing And Iaying Np-3 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Slngle Row Including Fixing Socket With Cement Mortar L:2 But Excluding Excavation, Protection Works Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 350Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 600Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 900Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1000Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1200Mm Dia , Laying Np-4 Pipe Reinforced Cement Concrete Concrete Pipe For Culvert On First Class In Single Row Includ Ng Flxing Socket With Cement Mortar 1:2 But Excluding Excavation, Protection Works, Backfilling, Concrete And Masonry Works In Head Walls And Parapets Clause 2900. 1400Mm Dia , Constuction Of Un-Reinforced, Plain Cement Concrete Avement Thickness As Per Disign, Over A Prepared Sub Base With 43 Grade Cement Or Any Other Type As Per Clause 1501.2.2 M-30 (Grade), Coarse And Fine Aggregate Conforming To Is 383, Maximum Size Of Coarse Aggregate Not Exeeding 25Mm, Mixed In A Concrete Mixer Of Not Less Than 0.2 Cum Acapacity And Apporopriate Weigh Batcher Using Approved Mix Design, Laid In Approved Fixed Side Formwork (Steel Channel, Laying And Fixing Of 125 Micron Thick Polythene Film Wedges, Steel Plates Including Levelling The Formwork As Per Drawing), Spreading The Concrete With Shovels, Rakes, Compacted Using Needle, Screed And Plate Vibrators And Finished In Continous Aperation Including Provision Of Contraction, Expansion, Construction And Constructionl Joints, Applying Debonding Strips, Primer, Sealant, Dowel Bars, Near Approaches To Bridge/Culvert And Construction Joints, Admixtures As Approved, Curing Of Concrete Slabs For 14 Days, Curing Comound (Where Apecified) And Water Finishing To Lines And Grade As Per Drawing And Technical And Technical Sepcification Clause 1501. (For Agra). (Chapter No.20 Si.No.12) , Construction Of Un-Reinforced, Plain Cement Concrete Pavement Over A Prepared Sub Base With Approve Grade Cement @ 400 Kg Per Cum, Coarse And Fine Aggregate Conforming To Ls 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed In A Batching And Mixing Plant As Per Approved Mix Design, Transported To Site, Laid With A Fixed Form Or Slip Form Paver, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints, Joint Filler, Separation Membrane, Sealant Prim Er, Joint Sealant, Debonding Strip, Admixtures As Approved, Curing Compound, Finishing To Lines And Grades As Per Drawing For Agra , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 60 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 80 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work.80 Mm (Rubber Molded Coloured) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Ordinary Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Grey) , Supply & Laying Of I Shaped (Zigzag) Precast Lnterlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50K9) Lncluding 0.30Mm Thick Local Sand Base Levelling And Dressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Complete Work. 100 Mm (Rubber Molded Coloured) , Re-Laying Of I Shaped Precast Interlocking Tiles Of Thickness 60 To 100Mm (Compressive Strength Not Less Then 30Mpa And Weight 4.50Kg) Including 25Mm Thick Loacal Sand Base Levelling And Ressing Of Surface To Required Level And Slope, Filling Joints With Local Sand All Comlete Work. Including Vat (Chapter No.20 Si.No.19 New Item) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe. (Lnternal Work - Exposed On Wall) 32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 40Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.(Lnternal Work - Exposed On Wall) 50Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.15Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.25Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fiftings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fiitings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Enoineer In Charqe.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.32Mm Nominal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 15 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 20 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 25 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 32 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 40 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 62.50 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 75 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 100 Mm Nonrinal Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineerin-Charge. External Work 150 Mm Nonrinal Dia Pipes , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 15 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 20 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 25 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 32 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 40 Mm Dia Nominal Bore , Providing And Fixing G.L. Pipes Complete With G.L. Fittings And Clamps, I/C Cutting And Making Good The Walls Etc.Lnternal Work Exposed On Wall. 50 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 15 Mm Dia Nominal Bore , Providing & Fixing Gl Pipes Complete With Gl Fittings And Clamps Including Making Good The Walls Etc. Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall: 20 Mm Dia Nominal Bore , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 60X60x75 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 90X90x100 Cm Lnside , Constructing Masonry Chamber Brick Work With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 150 In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) For Sluice Valve, With C.L. Surface Box 100Mm Top Diameter, 100 Mm Bottom Diameter And 180 Mm Deep ( Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ), I/C Necessary Excavation, Foundation Concrete 1:5:10 (1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Nrortar:3 (1 Cement: 3 Coarse Sand) 12 Mm Thick, Inished With A Floating Coat Of Neat Cement Complete As Per Standard Design 120X120x100 Cm Lnside , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Ls : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: W.C. Pan With Lsl Marked White Solid Plastic Seat And Lid , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Two Urinal Basins With 5 Litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Three Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing White Vitreous China Flat Back Or Wal Corner Type Lipped Front Urinal Basin Of 30X260x350 Mm And 340X410x265 Mm Sizes Respectrvely With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L Clamps Complete, Lncluding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required Range Of Four Urinal Basins With L0litre White P.V.C. Automatic Flushing Cistern , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require: (White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C. P. Brass Pillar Taps) {Chapter No.24 Si.No.5A} , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 550X400 Mm With A Pajr Of 15 Mm C.P. Brass Pillar Taps , Providing And Fixing Wash Basin With C.L. Brackets, 15 Mm C.P. Brass Pillar Taps,32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets,Cutting And Making Good The Walls Wherever Require:White Vitreous China Flat Back Wash Basin Size 550X400 Mm With Single 15 Mm C.P. Brass Pillartap , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.6A) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350 Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pi Pe, Spreaders With Unions And Clamps (All In C.P. Brass) With Waste Fitting As Per Ls:2556, C.L. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fittlngs And Cutting And Making Good The Walls And Floors Wherever Requlred:Range Of Two Half Stall Urinals With 5 Litre Pvc. Automatic Flushing Cistern , Constructing Brick Masonary Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 455X610mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (A) Inside Dimensions 455X610mm And 45Cm Deep For Single Pipe Line : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.6A) , Constructing Brick Massonry Chamber For Underground C.I. Inspection Chamber And Bends With Bricks In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) C.I. Cover With Frame (Light Duty) 600X850mm Internal Dimensions, Total Weight Of Cover With Frame To Be Not Less Than 38Kg (Weight Of Cover 23Kg And Weight Of Frame 15Kg), Reinforced Cement Concrete Top Slat With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size), Foundation Concrete 1 :5:10 (1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size), Inside Plastering 12Mm Thick With Cement Mortal 1:3 (1 Cement : 3 Coarse Sand), Finished Smooth With A Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Desing: (C) Inside Dimensions 600X850mm And 45Cm Deep For Pipe Line With Three Or More Inlets : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation M-150). {Chapter No.25 Si.No.8C) , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) Hindi Letters , Reinforced Cement Concrete M15 Grade Kilometre Stone Of Standard Design As Per Irc:8, Fixing In Position Including Painting And Printing Etc Sl No-804 As Per Direction Of Enginee-In-Charges Morth Standard Data Book. 5Th Kilometre Stone (Precast) (10 Cm Height Each) English Letters , Reinforced Cement Concrete M15 Grade Boundary Pillars/ Wheel Guard Of Standard Design As Per Irc:25-1967, Fixed In Position Including Finishing And Lettering But Excluding Painting , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.2 Metre High , Providing And Fixing L2 Metres High Gl Barbed Wire Fencing With 1.8 M Angle Iron Posts 40 Mm X 40 Mm X 6 Mm Placed Every 3 Metres Center To Center Founded In M15 Grade Cement Concrete, 0.6 Metre Below Ground Level, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With T Horizontal Lines And 2 Diagonals Intemoven With Horizontal Wires, Fixed With Gi Staples, Turn Buckles Etc. Complete As Per Clause 817 As Per Direction Of Enginee-Incharges Morth Standard Data Book. G.L Barbed Wire Fencing 1.8 Metre High , Deduction Of Cost Brick/Bats. (Chapter No.1 Sr.No.2(C)) , Deduction Cost Of Material Old Workable Bricks Etc. All Complete. , Road Delinator Delinealor Supply & Fixing Of M S Delineator Made Of L\Lild Steel With Pllre Polyester Powder Coating With The Minimum Thickness Of Powder Coating Of Not Less Than 40 Micron For Prolectlon Against Corlosion The Surface Should Be Concealed So That There Sholrld Not Be Any Exposed Surface Wilhout Powder Coating. Alternatively, These Metal Guide Poles Can Be Concealed With Thermoplastic Body. The Posts Shall Have Lan Ellipsoidal Or Circular Design Wilh The Height Of The Pole Shall Be 800 To 900 Mm Above The Ground With About 200 To 300 Mm Base Which Can Be Anchored Onto The Ground Mild Steel Guide Poles Shall Conform To Type Xl Sheeting Specifications As Per Lrc67 And Ast Ii D4956 Which Would Ensure To Obtainl Clear Visibility Of The Road Alignment During Nighl Time. The Relro Reflective Sheeting Shall Be Tested For Acertificale Of Having The Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Iiner Removal, Adhesion,Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdooa Weathering And Ils Having Passed These Tests Shall Be Obta Ned From Lnlernational/Government Laboratory / Lnslitute By The Manufacturer Of The Sheeinq And In Case The Cerliflcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condillon Within 3 Years Of Launching Of Product By The Manufaclure In Abroad. Alternatively, A Certillcate Conforming To Astlvl Specification (D4956 09) On Adficial Accelerated Weatherlng Requirements From A Reputed Laboratory In Lndia Can Be Accepted providing Sionally. Ln Such A Siluation, The Employer / Clienl, If So Desires, Collld Seek For A Performance Guarantee Which Would Be Released Alter Receipt Of Certiflcate Meeting The Requ Rement Of Three Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Report Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour. T&P, Transportation, Installation And Incidentals All Complete As Per D Recllon Of The Engineerincharge , Road Marking With Hot Applied Thermoplastic Compound With Reflectrosing Glass Beads On Bituminous Surface. Providing & Laying Of Hot Applied Thermoplastic Compound 2.5Mm Thick Including Reflecto Rising Glass Beads @ 250Gm/Sqm. Area, Thickness Of 2.5Mm Is Exclusive Of Surface Applied Glass, Beads As Per I.R.C. 35. The Finish Surface To Be Level Uniform And Free Form Steaks And Holes Composition Of Thermoplastic Material Shall Be As Per Table 800-3 Of Clause 803 Of Morth Including Cost Of Work As Per Direction E/Ic. (Chapter-28 Si.No.2) , Road Marking With Hot Appliod Ths.Moplastic Compound With Roflsctorlsing Glass Boads On Bituminous Surface. (Ropoated / Tranvers Bar) Providing And Laying Of Hot Applied Thermoplastic Compound 5 Mm Thick Lncludlng Reflectorising Glass Beads 0) 5Oo Gms Per Sqm Area, Thickness Of 5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc:35-2015 The Llnished Surface To Be Level, Uniform And Free From Streaks And Holes , 6M Span Over Head Cantilever Structure With 300 Dia M S One Vertical Post Supply, Fxing & Erection Of Built Up Canllever Structure 6 M Span Comprising Of One Verllcal Posts Of 6.00 I!4 Helght Made Up Of 300 Mm Nb Heavy Class Ms Pipe As Verllcal Member Welded With 10 Mm I\,4S Plate At Top & 12 Mm M S Plate At Bottom. The Horizontal Truss Shall Comprise Of 50 Mm Dia Heavy Class M.S. Pipe And 40 Mm Dia Heavy M S Pipe As Bracing & 10 Mm Ms Plate At Bottom For Llxing To Vertical Post As Per Structure Design & Drawing Wilh One Of Steel Primer And Two Coats Of Synthetic Enamel Planl. The Work Includes Constrlrction Of Reinforced Cement Concrete Foundation Of Size 0.90X0.90X1 50 M Of Required Depth As Per Site Conditlon For Built Up Structure Including Earlh Work In Excavation 100 Mm Thick Lean Concrete In 113:6 Cement Coarse Sand And 40 Mm Gauge Stone Ballast And Reinforced Cement Concrete M25 Grade Concrete Including Supply And Fixing Of 25 Mm Dia Foundalion Bolts 600 Mm Long As Per Provision Of Structure Design Includlng Cost Of Reinforcemenl & Shuttering. The Lateral Vertical Clearances And Complete. Nstallaton Work Shall Be As Per Relevanl Clauses Of Mort&H Speciflcation Section 8Oo And Irc 67 2012 Complete In All Respect The Raies Shall Include Cost Of Deslgn Fabricalion, Supply, Kansportalion, Local Shifting Erection Of Signage Skucture Using Crane, Inclusive Of All Taxes Etc. All T&P Machine, Malerial And Labour Requiled For Proper Completion Of Work As Per Direclion Of Engineer-Ln-Charge. , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilhout Shank) , Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply And Flxing Of Raised Pavement Marker With Made Of Plastic Body Of Rpimi Road Stud Shall Be Moulded From Asa (Acrylic Styrene Acrylonitrile) Or Hips (High-Lmoact Polystyrene) Or Acryloniilrile Butadien Styrene (Abs) Or Any Oiher Suitable Malerial Approved By The Engineer. The Marker Shall Support A Load Of 13,635 Kg Tested In Accordance With Astm D4280.The Reflective Panels Shall Consist Of Number Of Lenses Containing Single Or Dual Prismatic Cubes Capable Of Providing Total Internal Reflection Of The Lighl Entring The Lens Face. Lenses Shall Be Mouled Of Methyl Melhecrylate Conforming Io Astm D78b Of Equivalent The Slop Or Retro-Reflecting Surface Shall Preferably Be 35+1-5 Degree To Base And The Area Of Each Relro _Reflecling Sllrface Shall Not Be Less Than 13.00 Sq.Cm The Marker Height Shall Not Be Less Lhan 10 Mm And Shall Nol Exceed 20 Mm & Width Shall Not Exceed 130 Mm. The Base Of The Marker Shall Be Flal Within 1.3 Mm All Road Studs Shall Be Legibly Marked Wilh The Name , Lrade Or Other Means Of Identification Of The Manufacture. Epoxy Lnslallations, Excess Adhesive Around The Edge Of The Malker, Excess Adheslve On The Pavemenl And Adhesive On The Exposed Surfaces Of The Markers Shall Be Immedialely Removed. The Contractor Shall Submit A Two Year Warranty For Sal Sfactory Lleld Peformance Including Stipulated Retro-Refleclance Of The Reflecting Panel , To The Engineer . Ln Addition A Two Year Warranty For Salisfactory Infield Perfonnance Of The Finished Road Marker Shall Also Be Given By Lhe Conlractor Who Carries Out The Work Of Fixing Of Reflective Road Ma*Ers. Ln Case The Markers Are Displaced , Damaged . Gel Worn Out Or Lose Their Reflectivity Compared Lo Stipulated Standards , The Contractor Would Be Reqlllred To Replace Allsuch Markers Within 15 Days Ofthe Inlimation From The Engineer. At His Own Cost The Rate Shall Include All Materlals, Labour, T&P, Transportalion, Insiallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. Rpm (Wilh Shank) , Flexible Median Marksr As Per Irc 79:2019: Flexible Lmedian N4arker (Flv4nl) Should Be Used For Improving Medlan Visib Lity Dlrring Dark Hours. , Use Of L/Edian ]Varker Provides Safely Againsl Colision Happening Wilh Med Ans During N Ght Lime , Or Sevete Weather Flexib E L\.4Edian Markers Shall Be Provided With Fluorescenl Yellow Colour Retro-Refleci Ve Sheeting Type Xl As Per Irc:87. Flexible Lt4edian Lmarker Shall Be Ol Lough, High Impact Resistant, Lnieclion Molded, Lhermoplastic Body With Propery Of Flexibility Io Provide High Durabilityand U Shape Structure Having Rebound / Bollnce Back Properly. The Sheeting Shall Be Of Type Xl Conforming To Lrcl67 And Ii Should Be On Both The Faces Whereby Providing Maximum Refleclivity At L,Anger Distances With Adequate Durabllity. The Logo Of The Manufacturer Shall Be Embossed On Either Side Of The Body During The Lnjection Molding Process. Fi\4M Shall Be Fixed By A Combination Bf Epoxy Adhesive And Grouting/ Drilling On Concrete Medians Or Property Conslructed Solid Medians Heighl: The Marker Height Shall Be A Minimum Of 180 Mm Width 120 Mm & Body Thickness: 6.5 Mm. The Shanks Shall Not Be Less Lhan 20 Mm And Depth Shall Not Be Less Than 30 Mm Reflective Area: Shall Not Be Less Than G0 Cm Square . Proof Of Lhe Same Report Shall Be Uploaded Which Quollng Lender. The Body Of Fn,4[,4 Shall Bounce Back To Ils Origlnal Position Of Afier 750 Number Of Hits Using Pendulum Of 1.8 Kg Conforming 40 Astm D256 Adhesion Between The Body And Outer Casing Body Of Fmi\4 Shall With Stand 50 Kg I Tensile Loads Conforming To Astm D63b Method. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer-Ln-Charge. , Painting Lines, Dashes, Arrows, Etc. On Roads Ln Two Coats On New Work Painting Lines, Dashes, Arows, Etc On Roads In Two Coats On New Work Wilh Ready Mixed Road Marking Paint Cinforming To Ls:164 On Bituminolls Surface, Including Cleaning The Sullace Of At Dirt, Dusi And Other Fore Gn Matte., Demarcation At Site And Trafllc Control . Over 10 Cm. In Width , Linear Dstinoator Systsm (Lds) Supply & Fixing Of Linear Delineator System (Lds) Panels Made Of Micro Prismatic Retro Reflective Sheeting Type Xl Duly Laminated On Thin Aluminium Foil To A Unique Corrugated Shape To Provide Retro Reflection Across Wide Range Of Observaiions And External Angles. Eatch Lds Panel Should Be Of Nominal Lenglh Of 33 Inch And Each Ridge Shall Be Approximately 0.34 Inch High Each Lds Panel Is To Be Firmly Fixed On Existing Concrete/Brick Work With 16 Nos Fastner/ Screw , Retro-Roflectivesheeting Type-Lv With 4 Mm Thick Acm Single Side Providing & Flxing Of Reflective Signs With A Corrosion Resistant 4 Mm Thick Wlth 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Lace To Be Iully Covered With Hlgh Lntenslty Prlsmatic Sheetlng Type Lv As Per Irc-6712012 Relro Refleclive Sheeling With Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Elc Shollld Be As Per Morth Speciflcation No Bo1.3.7 .The Sheelng Shall Have A Pressure - Sensltive Adhesive Of The Aggressive - Tack Type Requiring No Heat , Solvent Other Preparation For Adhesion 10 A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acim (Aluminium Composite Materials) Shall Be Flxed On The Back Frame Nis Angle Wiih Riveting. Micro Prismalic Type Lv Retro Rellective Sheeting Conilrming 1O Astm 04956-09 Shall Be Pressure Lixed. The Retro Reflective Sheeting Shall Be Tested For A Cerlillcate Of Having The Sheeting Tesled For Coetllcient Of Retro Refleclion, Dayume Colour And Luminance, Shrinkage, Flexibilily, Liner Iemoval, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed Lhese Lesls Shall Be Obtained From Lnlemational/Government Laboratory/ Lnstitute By The Manufacture. Of The Sheetng And In Case The Certiflcate Is Oblalned From International Condilion, T Should Also Be Obtained From Lndian Condilion Within 3 Years Of Launching Of Producl By The Manufactllre In Abroad. Alternalively, A Cerliilcate Conforming To Astm Specification (D 4956-09) On Artiilcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, Lhe Employer/Client, If So Desires, Could Seek For A Petlotrnance Guarantee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirement Of Lhree Years Outdoor Wealhering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo.T Shall Be Uploaded Whlch Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Lransportation, Installation And Lncidentals All Complete As Per Direction Of The Eng Neer-In-Charge. , Retro-Reflectivesheeting Type Iv With 4 Mm Thjck Acm Double Side: Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Lhlck With 0.4 To 0.5 Mm Both Side Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Tntensity Prismaiic Sheeling Type Lv As Per Irc-67:2012 Retro Reflective Sheeting With Back Frame Ms Angle Of 35X35x5 Mm Legends Letters , Numerals And Borders Elc Should Be As Per Morth Specification No801.3.7 The Sheeting Shall Have A Pressure - Sensitive Adhesive Of The Aggressive - Tack Type Requiring No Heai, Solvent Olher Preparation For Adhesion To A Smooth Clean Surface, Ln A Manner Recommended By The Sheeling Manufacturer. The Acn,4 (Aluminium Cornposite L\,4Aterials) Shall Be Ilxed On The Back Frame Ms Angle With Nveling. Micro Prismatic Type Lv Retro Refleclive Sheeting Conflrming Io Astm D4956-09 Shall Be Pressure Llxed. The Reko Reflective Sheeling Shall Be Tesled For A Cedificate Of Having The Sheeting Tested For Coemcient Oi Reko Reflection, Daytime Colour And Luminance, Shrinkage Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resislance, 3 Years Outdoor Weatherlng And Its Having Passed These Tests Shall Be Obtained From Lnternallonal/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeting And In Case The Certificale Is Oblained From International Condition It Should Also Be Obta Ned From Lndian Condilion Wilhin 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certilicate Conforming 10 Astm Speciflcatlon (0 4958-09) On Aatiflclal Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepled Provisionally. Ln Sllch A Situation, The Employer/Client If So Desires, Could Seek For A Performance Guarantee Which Would Be Released Afler Receipl Of Cerlillcate Meeting The Requirement Of Lhree Years Outdoor Weathering Of The Sheeling As Per Irc 67I2012 & Proof Of The Same Repofl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installalion And Incidentals All Cornplete As Per Dlreclion Of The Engineer-In-Charge , Retro-Refle.Ctivesheeting Type-Xl With 4 Mm Thick Acm Single Side Providing & Fixing Of Reflective Signs Wilh A Corrosion Resistant 4 Mm Thick With 0.4 To 0.5 Mm Both Slde Aluminium Skin Alumlnium Composite Panel Face To Be Fully Covered With High Lntensity Prismatlc Sheeting Type Lv As Pet Irc-67:2012 Reko Reflective Sheeling With Back Frame L\,4S Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per L\Lorth Specification No_ 801.3.7 The Sheeting Shal Have A Pressure - Sensitive Adhesive Of The Aggressive Tack Type Requiring No Heal Solvent Other Preparation For Adhesion To A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer. The Acm (Alllminium Composite L\,4Aterlals) Shall Be Fixed On The Back Frame Ms Angle With Riveting. Micro Prismatic Type Lv Retro Reflective Sheeung Conflrming To Astlvl D4956-09 Shall Be Pressure Fixed. The Relro Reflective Sheeting Shall Be Tested For A Cefiilicate Of Having The Sheeting Tested For Coeificient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Iungus Resistance. 3 Years Outdoor Weathering And Lts Having Passed These Tests Shall Be Obtained From Lnlernational/Government Laboraiory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cefiificate Ls Obtained From Lnternational Condition. It Should Also Be Oblalned From Lndian Condition Wilhin 3 Years Of Launching Of Producl By The Manufacture In Abroad. Alternatively, A Certificate Conforming To Astii Speciflcation (D 4S5b-09) On Adiflcial Accelerated Weathering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Prcvisionally. Ln Such A Siluation, The Employer/Client, If So Desires, Could Seek For A Performance Guaranlee Which Would Be Released After Receipt Of Certiflcate Meeting The Requirernent Of Three Years Outdoor Weathering Of Lhe Sheeting As Per Irc 67:2012 & Prooi Of The Same Reporl Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpoftalion, Installation And Incldentals All Complete As Per Direction Oi The Engineer-Ln-Charge , Retro-Reflectlveshoeting Type-Xl With 4 Mm Thick Acm Double Side Providing & Rlxing Of Reflective Signs With A Colrosion Resistanl 4 Mm Thick With 0.4 To 0.5 Mm Both Side Aluminium Skin Aluminium Composite Panel Face Lo Be Iully Covered With High Lntensity Prismatic Sheeling Type Lv As Per Irc-67:2012 Relro Retlective Sheeting Wlth Back Frame Ms Angle Of 35X35x5 Mm. Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specification No_ Bo1.3.7 .The Sheeting Shall Have A Pressure - Sensilive Adhesive Of The Aggressive - Tack Type Requiring No Heat, Solvent Other Preparation For Adhesion Lo A Smooth Clean Surface, In A Manner Recommended By The Sheeting Manufacturer, The Acn,4 (Aluminlum Composite Materlals) Shall Be Fixed On The Back Fiame Ms Angle With Riveting. Micro Prismalic Type Lv Retro Reflective Sheeting Conflrming To Astm D4956 09 Shall Be Pressure Fixed. The Relro Refleclive Sheeting Shall Be Tested For A Ce(Iilcate Of Having The Sheeting Tested For Coefllcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Funqus Resistance. 3 Years Outdoor Weathering And Its Having Passed These Tests Shal Be Oblained From Lnternationa /Governmenl Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case Lhe Certillcate Ls Obtained From Internalional Condition, It Should Also Be Obtained From Lndian Condition Within 3 Years Of Launching Of Product By The Manufacture In Abroad Alternalively, A Ce(Iilcate Conforming To Astm Specification (D 4956-09) On Artiflcial Accelerated Wealhering Requirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Sltuation, The Employer/Cllent, If So Deslres Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cedillcate Meeling The Requirement Of Lhree Years Outdoor Weathering Of The Sheeting As Per Irc 67:2012 & Proof Of The Same Repo( Shall Be Uploaded Which Quoting Tender. The Rate Shall Include All Materials, Labour, T&P, Transpo.Tation, Installation And Incidentals All Complete As Per Direction Of The Engineer-In-Charge , Bollard (Single Sido) Supply & Fixing Of Bollard Made(Single Side) Out Of2mm Thick Aluminium Sheet Face Lo Be Covered With High Intensity Prismatic Grade Type Lv Sheeting , Legends , Letters , Numerals And Borders Etc Should Be As Per Morth Specillcation No-801.3.7 . Welded Poly Shaped To Make It Monolithic Pillar Size 12Oo Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Is Fully Cover (Size Of Foundation 0.45X0.45X0.60M) , Bollard (Doublo Side) Supply 8, Fixing Of Bollad Made (Double Side) Out Of 2Mm Thick Aluminium Sheet Face To Be Covered With High Intensity Prismatic Grade Iype Lv Sheeting Legends , Letters , Numerals And Borders Etc Should Be As Per Morih Specification No-801.3.7. Welded Poly Shaped To Make It Monolithic Pillar Size 1200 Mm High Bollard Is Having A Frame 900X600 Mm And 600 Mm Dia For Fixation Made Out Of 35 X 35 X 5 Mm Angle Iron And From Side Ls Fully Cover. (Size Of Foundalion 0.45X0.45X0.60M) , Solar Power Road Marker (Solar Studs) The Solar Studs Shalt Be Made Of Aluminium Alloy And Poly Carbonate Material Which Shall Be Absolutely Weather Resistant And Strong Enough To Support A Load Of 13,635 Kg Tested In Accordance With Ast[4 D4280. Lts Co]Our May Be While . Red , Yellow , Green Or Blue Or Combination As Directed By The Engineer . Its Water Resislance Shall Meet Lhe Requiremenls Of Lp 65 In Accordance Wilh 15:12063:1987 Category 2 For Protection Againsl Water Ingress The Dimensions Of Solar Sluds Shall Not Be Less Than 100 Mm X 100 Mm X 10 Mm Ltshall Have Super Bright Leds So As To Provide Long Visibillty From A Distance Of More Than B0o M. Lts Flashing Rate Shall Not Be Less Than1 Hz Lts Should Be Able To Glve The Prescribed Performance In The Temperrature Range Of - 40C To +55C Lts Life Shall Be Not Less Than 3 Years. The Rate Shall Include All Materials, Labour, Equipments, Fabrication, Transportation, Erecuon, Installation And Incidentals All Complete As Per Direclion Of The Englneer-In-Charge , Cast-Ln-Situ Cement Concreto M 20 Kerb Construction Of Cement Concrete Kerb With Top And Bottom Width 115 And 165 Mm Respectively, 250 Mm High In M 20 Grade Plain Cement Concrete On M-10 Grade Foundation 150 Mm Thick, Foundation Having 50 Mm Projection Beyond Kerb Stone, Kerb Stone Laid With Kerb Laying Machine, Foundation Concrete Tad Manually, Alt Complete As Per Clause 408. , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 90 Cm Equllateral Tringle With Dif,Lnitation Plate Size (20Cm X 60Cm , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Eqlrilateral Trinqle With Difflnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm Circular With Difflnltation Plale (20Cm X 60Cm) . , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government B0 Mm X 60 Mm Reclangu annual repair With Difllnitation Plate (20Cm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Mm X 45 Mm Rectangular With Difllnitation Plale (2Ocm X 60Cm) , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 60 Cm X 60 Cm Square With Difflnitation Plate (20Cm X 60Crn) , Direction And Place Identification Signs Up To 0.90 Sqm Size Board Providing And Erecting Directlon And Place Identification Retro Reflectorised S Gn As Per Irc-67 Made Of High Intensily G.Ade Sheeting The Relro Reflective Sheelng Shall Be Tested For A Certiicate Of Having The Sheeling Tested For Coefficient Of Reko Reflection. Daytime Colour And Luminance, Shrinkage, Flexibllity. Liner Removal Adhesion, Impacl Resislance, Specula. Gloss And Iungus Resistance, 3 Years Ouldoor Weathering And Its Having Passed These Tesls Shall Be Obtalned From Lnternational/Govemment Laboraiory/ Lnslitule By The Manufacturer Of The Sheeting And In Case The Certillcate Is Obtained From International Condition, It Should Also Be Obtained From Lndian Condltion Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternatively, A Certiflcate Confonning To Ast[4 Specification (D4956 09) On Art Ficial Ccelerated Wealhering Requirements Faom A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer I Client, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Lhree Years Olrtdoor Weathering Of Lhe Sheeting As Per Irc 67 2012. Legends , Letters , Nurrerals And Borders Etc Should Be As Per Imorth Speciilcation No-801.3.7 Sheet Fixed Over Aluminium Sheetinq .2 Mm Thick Wilh Area Not Exceeding 0.9 Sqm.Supported On A Mild Steel Single Angle Iron Post 75X75x6 Mm Flrmly Fixed Lo The Ground By Rneans Of Property Designed Foundalion With N,4-15 Grade Cement Concrete 45X45x60 Cm.,Below Ground Lcvcl As Pcr Approvcd D.Awing. Complete. , Tree Plats Supply & Fixing Of Retro Reflective Tree Plate Having Size 15Cm X15cm, Conjisiing Type Xl Retro Reflective Sheeting Lixed Over 1.50 Mm Thick Aluminiu; Sh;Et Including Labour, Material T&P Etc For Proper Completion Of The Work. The Rate Shall Include All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Of The Engineer-Incharge. , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 1000 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 750 Mm Helght , Traffic Cone Traffice Cone: Supply Of Red Fluorescent Wilh With Refleclive Sleeve Trafflc Cone A Squre Base Of 300 To 500 Mm & Thickness 35 Mm And A Heiht Of 1000 Mm To 500 Mm. Thay Shall Be Brilliant Red / Orange / Yellow And Shall Be Made Of Ldpe Material Ihat Can Be Struck Without Causing Damage Lo Lmpacting Vehicles. Retro-Reflect Orization Of Cone Shall Be Provided By A 150 Mm Wide While Band Located 75 Lo 100 Mm Irom The Top Of The Cone And Additional 100 Mm Wide White Band Located Approximately 50 Mm Below The 150 Mm Band The Rate Shallinclude All Materials, Labour, T&P, Transportation, Lnstallation And Incidentals All Complete As Per Direction Ofthe Engineer-In-Charge. 500 Mm Helght , Aluminum-Backed Flexible Prismatic Sheeting Shall Be Made Of Yellow Colored Flexible Prismallc Sheeting With Non-Rnetallic Prismatc Lens Formed In A Lransparent, Synthelic Resin As Retro Leflective Elements. This Llexible Prlsmatic Sheeting Shall Have Black And Yellow Stripes With Aluminum Backed Flexible Prismatic Type Vl Sheeting Conforming To Astm: D4956 . Specifications And Standards Of Coefllcient Of Relro Refleclivity, Flexibility And Lmpact Resislance Applicable For Reboundable Devices This Flexible Prismatic Sheeting Shall Have Screen Printed Arrow/Slant Line Pattern In Black Colour In A Continuous Roll Format. Wldlh Of Object Marker Shall Be 300 Mm. The Rate Shall Include All Materials, Labour, T&P, Transportation, Installation And Incidentals All Complete As Per Direclion Of The Engineer In-Charge , 2.40 M Span Over Head Cantilever Structure With 150 Die Ms One Vertical Post (Double Side Retro Reflective Sign Boards) Supply, Fixing & Eraction Of Built Up Cantilever Structure 240 M Span O.PiiIng Oi One Ve.Tical Posts Of 7 30 N4 Heighl Made Up Of 150 Mm Nb Medium Class T\4S Pipe As Vertical Memberwelded With 10 Mm Ms Plate At Top & Lo Mm Lvls Plate At Boltom. Flxing To Vertical Post As Per Structllre Design & Drawing Wiih One Of Steel Primer And Two Coats Of Synthetic Enamel Plant And The R;Tro Reflective Sheetinq Shall Be Tesled For A Certifcale Of Having The Sheeting Tested Fo. Coemcient Of Retro Reflection, Daylime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Resistance, 3 Years Olltdoor Wealhering And Ils Having Passed These Lests Shall Be Obtained From Lnternational/Government Laboraiory/ Lnstitute By The Manufactllrer Of The Sheeting And In Case The Certificate Is Obtained From Internatlonal Condilion, It Should Also Be Obtained From Lndian Condition Wilhin 3 Years Of Launchlng Of Product By The Manufacture In Abroad. Alternatively, A Cedificate Confonning Io Astm Speciflcation (0 4956 09) On Artificial Accelerated Weathering Reqllirements From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. N Such A Sltuation, The Employer / Client, If So Desiaes. Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerllllcate Meeting The Requirement Of Three Years Outdoor Weathering Ol Lne Sheeling As Pel Irc 67 2012 . Legenos . ,Etters . Numerdls And Borders Elc Sholllo Be Asperl\,4Orlh Specif,Calion No_801 37 The Work Includes Construction Of Reinforced Cement Concrete Foundation Of Size 0.60X0.60X1.20 M Of Required Depth As Per Site Condilion For Built Up Struclure Lncluding Earth Work In Excavation 100 Mm Thick Lean Concrete Ln 1:3:6 Cemenl Coarse Sand And 40 Mm Gauge Stone Ballast. Reinforced Cement Concrete Lm25 Includlng Supply And Fixing Of 25 Mm Dla Foundalion Bolts 600 Mm Long As Per Provision Of Slructure Design Including Cost Ot Reinforcement & Shuttering. The Lateral Vertical Clearances And Complete. Lnstallation Work Shall Be As Per Relevant Clauses Of Mort&H Specitlcation Seclion 800 And Irc 67 2012 Complete In A I Respect The Rates Shall Inclucle Cosl Ol Design Fabrication, Supply, Lransporlalion, Local Shifling Erection Of Signage Slructure Using Crane, Incluslve Of All Taxes Etc All T&P Machine, Material And Labout Required For Proper Completion Of Work As Per Direction Of Engineer-In-Charge , Retro-Reflectorised Traffic Sign As Per Irc-87-2012 Providing And Flxing Of Retro-Reflectorised Caulionary, Mandalory And Informalory Sign As Per Irc 167-2012 Made Of High Intensily Grade Sheeting Type Lv Vide Clause 801.3, Fixed Over Aluminium Sheeting 15 Mm Thick Supported On A Mild Steel Angle Iron Post 75 Mm X 75 Mm X 6 Mm Ilrmly Fixed To The Ground By Means Of Properly Designed Foundation With M 15 Grade Cement Concrete 45 Cm X 45 Cm X 60 Cm. 60 Cm Below Ground Level As Per Approved Drawing. The Retro Reflective Sheeting Shall Be Lested For A Cerliilcate Of Having The Sheeling Tested For Coetflcient Of Retro Reflection, Daytime Colour And Luminance, Shrinkage, Flexibility, Liner Removal, Adhesion, Impact Resistance, Specular Gloss And Flrngus Resistance 3 Years Outdoor Weatherrng Anci Ils Having Passed Lhese Lesls Shall Be Obtained From Lnternational/ Government Laboratory/ Lnstitute By The Manufacturer Of The Sheeting And In Case The Cerlillcate Is Obtained From Lnternatlonal Condition, It Should Also Be Obtained From Lndian Condiuon Within 3 Years Of Launching Of Product By The Manufacture In Abroad. Alternalively, A Certiflcate Conforming To Asti\,4 Specillcation (0 4956-09) On Artiflcial Accelerated Weathering Requirements From A Reputed Labo.Atory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Client, If So Deskes, Could Seek For A Peformance Guarantee Which Would Be Released After Receipt Of Cerlificate Meeting The Requirement Of Three Years Olrtdoor Weathering Of The Sheeting As Per Irc 67.2012. Legends,Lellers, Numerals And Borde.S Etc Should Be As Per Aiorth Speciflcation No-801.3.7 . Proof Of The Same In Form Of Government 30X90 Cm (Lefrright) Object Hazard , Retro Rellectorisod Signs (Stajnless Steel Frame And Post With One Side Sings) Supply & Fixing Of Reflective Sign Board (Single Side) Of Size 1.50X1.20 M Retro Refleclive Sheeling Of Hip Grade Type-Lv, Lhe Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick, Acm Sheel Of Standard Make As Per Morth Specificaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Cm Cement Conclete Foundauon. The Stainless Steeljoint Welding Of Ss Pipe Work Shall Be Band And Grinder Property Including Bufflng So An To Give Uniiorm Shining At Weded Joinls. The Retro Reflective Sheellng Shall Be Lested For A Certiflcate Of Having Ihe Sheeting Tested For Coefficienl Of Retro Reflection, Daytime Cololrr And Luminance, Shrinkage, Flexibility, Linet Removal, Adheslon, Impact Resistance, Specular Qloss And Fungus Resistance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Governmenl Laboratory/ Institute By Lhe Manufacturer Of The Sheeting And Ln Case The Cedillcate Is Obtained From Inlernational Condition, It Should Also Be Oblained From Lndian Condition Within 3 Years Of Launching Of Procluct By The Manufacture In Abroad Allernatively. A Certiflcate Confolrnlng To Astm Specilicalion (D 4956-09) On Artiflcial Acceleraled Weathenng Requirements From A Reputed Laboratory Ln Lndia Can Be Accepled Provislonally. Ln Slrch A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificale Meeting The Requirement Of Three Years Ouldoor Weathering Of The Sheeting As Per Irc 67I2012. Legends , Letters , Numerals And Borders Elc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Governmenl Repod Shall Be Uploaded While Quoting Tender. , Retro Reflectorised Signs (Stainless Steel Frame And Post With Both Side Sings) Slrpply & Fixing Of Reflecllve Sign Board (Sing E Side) Of Size 1.50X1.20 M Retro Reflective Sheeting Of Hip Grade Type-Lv, The Board Shall Be Fixed On 50Mm Ss 304 Grade Pipe And Refleclive Sheet On 4 Mm Thick Acni Sheet Of Standard Make As Per Morth Speciilcaton. The Board Shall Be Fixed Using 2 Man Post 45X45x60 Crn Cement Concrele Foundation The Stainless Steelioint Welding Of Ss Pipe Work Shallbe Band And Grinder Propefiy Including Butting So An To Give Uniform Shining At Weded Joints. The Relro Reflective Sheeting Sha I Be Tested For A Certificale Of Having The Sheeling Tested For Coefficient Of Retro Reflection Daytime Colour And Luminance, Shrinkage. Flexibiity, Llner Removal, Adhesion, Impact Resistance, Specular Gloss And Fungus Reslstance, 3 Years Outdoor Weathering And Its Having Passed These Tests Shall Be Obtained From Lnternational/Government Laboratory/ Lnstitute By Lhe Manufacturer Of Lhe Sheeling And Ln Case The Certiflcate Is Obtained Lrom Lnternational Condition, It Should Also Be Obtained From Lndian Condition Wlthin 3 Years Of Launching Of Product By The Manufacture In Abroad. Allernatively, A Cerlificate Conforming To Astm Specificalion (0 4956.09) On Artificial Accelerated Weathering Requlremenls From A Reputed Laboratory In Lndia Can Be Accepted Provisionally. Ln Such A Situation, The Employer / Clienl, If So Desires, Could Seek For A Performance Guarantee Which Would Be Released After Receipt Of Certificate Meeting The Requirement Of Three Years Outdoor Weather Ng Of The Sheeting As Per Irc 67I2012. Legends. Letters, Numerals And Borders Etc Should Be As Per Morth Specification No-801.3.7 . Proof Of The Same In Form Of Government Report Shall Be Uploaded Whlle Quoting Lender. , Type - A, W : Metal Beam Crash Barrier Providing And Erecting A W Metal Beam Crash Barrler Comprlsing Of 3 Mm Lhick Coffugated Sheet Melal Beam Ral 70 Cm Above Road/Ground Level Flxed On Ismc Series Channel Vertical Posl, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.8 M High. 1.1 M Below Grolnd/Road Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fltlings To Conform To Lsi1367 And 15:1364. Metal Beam Rail To Be Fixed On The Vedical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 Mm Long Complete As Per Clause 810 , Type - B, Thrie : Metal Beam Crash Barrier Providing And Erecting A Thrie Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Melal Beam Rail,85 Cm Above Road/Ground Level, Fixed On Isi\Ic Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Cenlre To Cenke, 2 M High With 1.15 M Below Ground Level, All Steel Parts And Fltments To Be Galvanised By Hot Dip Process, All Fittings To Conform Lo Lsl1367 And Ls:1364 Metal Beam Rail 10 Be Fixed On The Verlical Post With A Space Of Channel Seclion 150 X 75 X 5 Mm, 546 Mm Long Complete As Per Clause 810 , Anti-Termite Treatment The Soil Along With External Perimeter Of Building At The Rate Of 2.5 Litres Of Emulsion Per Square Metre Of The Perimeter Wall {Chapter No.08 Si.No.5} , Anti-Termite Treatment Of The Bottom And Sides Of Excavation At The Rate Of 5Litres Of Emulsion Per Square Metre Of Surface Area {Chapter No.08 Si.No.1} , Anti-Termite Treatment Of The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface{Chapter No.08 Si.No.3} , Anti-Termite Treatment Of The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface {Chapter No.08 Si.No.4} , Anti-Termite Treatment Of The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (Area Of The Sub Structure In Contact With Backfill To Be Measured) {Chapter No.08 Si.No.2} , Treatment Of Existing Masonry Using Chemical Emulsion @ One Litre Per Hole At 300 Mm Interval Including Drilling Holes At 45 Degree And Plugging Them With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To The Full Depth Of The Hole : With Chlorpyriphos/Lindane E.C. 20% With 1% Concentration {Chapter No.08 Si.No.6-2.35.4.1} , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration {Chapter No.08 Si.No.6-2.35.3.1} , Providing And Stacking 22.40-53Mm Guage Stone Aggregates Of Specific Sizes To Water Bound Macadam Specification Including Etc All Complete.(Ns) , Supply And Laying Stone Dust Etc All Complete. , Consolidation/Compaction Of Stone Ballast 10Cm Thick (Loose) Coat Including Repairing Of Patches Picking Up To Old Surface Spreading, Ballast Making Medhies To Retain Water And Carriage Of Metal Upto 30M Carriage Of Water Upto 200M Maintenance Of Barriers And All Labour T&P Including Road Roller Charges Etc. Required For Proper Completion Of Work The Stone Ballast Is To Be Supplied To The Contractor Free Of Cost At Site. , Scarifying The Existing Bituminous Road Surface To A Depth Of 150 Mm And Disposal Of Scarified Material With A Lift Upto 3 M And Lead Upto 1000 M As Per Technical Specification Clause 301.4 {Chapter No.20 Si No.16} , Providing And Applying Primer Coat With Ss1 Grade Bitumen Emulsion On Prepared Surface Of Granular Base Including Clearing Of Road Surface And Spraying Primer At The Rate Of 0.70 Kg/Sqm Using Mechanical Means. (As Per Attached Analysis) , Providing And Laying Dense Graded Bituminous Macadam With Higher Capacity Batch Type Hmp Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder @ 4.5 Per Cent By Weight Of Total Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification Clause No. 505 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , Providing & Applying Tack Coat With Bitumen Vg-10 Using Bitumen Pressure Distributor At The Rate Of 0.30Kg/Sqm. On The Prepared Primed Granular/Old Painted Surface. Cleaned With Air Compressor. Including All Taxes, Material, Labour, T&P Etc Required For Proper Completion Of The Work. (For Bituminous Surface). (Chapter No.20 Si No.9) , Providing And Laying Bituminous Concrete (Grading-Ii) With 100-120 Tph Hot Mix Plant Producing An Average Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminous Binder Vg-30 As Per Approved Job Mix Formula Which Ever Is Higher Of Mix And Filler, Transporting The Hot Mix To Work Site, Laying With A Hydrostatic Paver Finisher With Sensor Control To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction As Per Morth Specification 5Th Revision Clause No. 509 Complete In All Respects Including Cost Of All Materials, T&P, Labour, Cartage For Proper Completion Of Work As Per Direction Of Enginee-In-Charges. (20-Chapter Analysis Rate) , S/L/J Of 20Mm Dia Pvc Cunduct Pipe Etc. All Complete. , Making Of Nala Bandha With Sand Bags. With Local Sand Including Etc. All Complete. (Atached Per Annalysis Rate). , Providing Of Nala Bandha For Diversion Of Nala Etc All Complete.(Ns) , Scraping Of Max Phalt Road Including Disposal Of All Scraped Material To A Distance Of 30Mtrs (100 Ft) As Directed By Engineer-In-Charge C.P. & T&P.Etc. All Complete. {Chapter No.20 Si No. 772(A)} , Dismentling Existing Damage Plaster Including Disposal Of Refuse As Directed By E/Ic With In A Distance Of 60 Meters Etc. All Complete. {Chapter No. 17 S.I. No.16 (706)} , Supply And Fixing Of Light Fitting Switch Board. (None Sheduled) , Fixing Of Gate, Grill And Jali Etc. All Complete. (None Scheduled) , Supply & Fixing Of Wiring Sub Main. , Supply & Fixing Of Plug Point 15Mm. , Supply And Fixing Oxided Iron Fitting Etc. All Complete (None Scheduled) , Supply/Fixing Of 16 Mm Pvc Pipe Adopter Suitable For Item No. , Supply/Fixing Of 20 Mm Cvc Pipe Adopter Suitable For Item No. , Supply & Fixing Of 27Watt. Cfl Etc. All Complete. , Supply And Fixing Cat Eye Including Supply Of All Material, Loabour, T&P Etc. All Complete. (Chapter No.28 Si.No.5B) , Supply And Fixing Wiring Of Light Point. (None Sheduled) , Making Connection Of Drain Of Sewer Line With Existing Man Hole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Cement Plastered On Both Side With Cement Mortar 1:3 Finished With A Floating Coat Of Neat Cement And Making Necessary Channels With Cement Concrete 1:2:4 For The Drain Etc. All Complete. (Chapter No.25 Si.No.9) , Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Of Size 20 Mm Nominal Size) Laid In One Layer Finished With A Floating Coat Of Neat Cement (40 Mm Thick Floor). (Si No. 665), Nbo 14.71) , Providing And Fixing Of Foot Steps Etc All Complete. (Ns) On Market Rate , Providlng And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Ls:8931.15 Mm Nominal Bore , Supply & Fixing Of C.P. Brass Stop Cock (Conceled) Of Standerd Design Of Approve Quality Etc. All Complete. (Chapter No.21 Si.No.44) , Providing And Fixing Close Timbering In Trenches On Both Side & All Complete. (A) 0.00 To 3.00 M. (None Scheduled) , Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Ls:8931..15 Mm Nominal Bore , Fixing Window Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Ls Standards And Weighing Not Less Than 690 Qms.15 Mm Nominal Bore , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 75Mm Diameter. (Chapter No.23 Si.No. 32(Ii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 110Mm Diameter. (Chapter No.23 Si.No. 32(Iii)) , Providing And Fixing Pvc Pipe Conforming To Isi Make Working Pressure 6 Kg/Cm Including Testing Labour T&P Etc. All Complete. 140Mm Diameter. (Chapter No.23 Si.No. 32(Iv)) , Rectangular Shape 1500X450 Mm Mirror With Plastic Moulded Frame. (Chapter No.22 Si.No.77) , Making Ornamental 2D Painting With Special Design Make By Specialist Painter Laying Of Two Coat Birla White Putty And Design By Asian Paint Including All Material Etc. All Complete. (Nn Approved) , Providing Of 8Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Fixing Door Chowkhats In Existing Opening Including Embedding Chowkhats In Floors Or Walls Cutting Masonry For Holdfasts, Embedding Hold Fasts In Cement Concrete Blocks Of Size 15X10x10 Cm With Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand :6 Graded Stone Aggregate 20 Mm Nominal Size), Painting Two Coats Of Approved Wood Preservative To Sides Of Chowkhats And Making Good The Damages To Walls And Floors As Required Complete, Including Disposal Of Rubbish To The Dumping Ground, All Complete As Per Direction Of Engineer-In- Charge. (Chapter No.9 Si.No.7A-14.2.1) , Supply And Fixing 6Mm (1/4) Thick Chine White Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar And Approved Coarse Sand Mortar Finished With White Cement Jointed And Polishing Complete Including Supply Of All Materials, Labor For Porper Completion Of The Work. (Chapter No.14 S.I. No. 628) , Supply & Fixing Of Pre-Cast M-30 Cement Concrete Grass Paver (Rubber Molded Coloured) Over 40Mm Thick Local Sand Bed, With 3Mm Thick Joints Filled With Local Sand Including Leveling, Tempering And Sweeping Etc., Interlocking Bricks Will Be As Description Given In Direction Issued By The Ircsc-03-2004 And Should Be Isi Marked All Complete. 80Mm Thick, Strength Should Not Less Than M-30. (Tiles I Shape Decided By Engineer-In-Charge With Isi Mark) {Chapter No.20 Si.No.17F) , Repairing Of Leakage And Damege Pipe Line Etc All Complete.(Ns) , Lettering & Painting Of Wall Etc. All Complete. , Red Sand Stone Work For Wall Lining Etc. (Veneer Work) 30Mm Thick In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Camping Jointing In White Cemnet Mortar 1:2 (1 White Cement : 2 Stone Dust) With An Admixture Of Pigment Matching Complete. (Chapter No.18 Si.No.1 New) , Providing And Fixing White Vitreous China Wash Basin Size 630X450mm With Pair Of 15Mm C.P. Brass Pillar Taps Including Etc. All Complete. (Chapter No.24 S.I. No. 3(A)) , Cleaning Of The Site For Workable Etc. All Complete. (Non Scheduled) , Providing Of 32Hp Desel Pump Set For Dewatering Including Hire And Fuel Charge With Operator Etc. All Complete. (None Scheduled) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 1200X600x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 600X450x150mm Etc All Complete. (As Per Market Rate) , Supply Of Pre-Cast Reinforced Cement Concrete Slab Size 900X450x100mm Etc All Complete. (As Per Market Rate) , Fixing Of Reinforced Cement Concrete Slab Etc All Complete. (Ns) , Raising & Re-Fixing Of Manhole Including All Material Labor T&P Etc. All Complete. (Non Scheduled) , Supply & Fixing Reinforced Cement Concrete Menhole Cover Heavy Duty Size Etc. All Complete. (Non Scheduled) , Providing Laying Spreeding And Compacting 45-90Mm Stone Agreegate For W.M.M. Specification Etc. All Complete. (None Scheduled) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan) With 100Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Wall And Floors Wherever Required : White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With With Integral Type Foot Rests. (Chapter No.24 Si. No.1) , Providing Of 3D Ornamental Wall Art Painting By Architect & Special Painter Including Scrapping Of Wall And Two Coat White Putting White Putty One Coat Primer All Labour Scaffolding Work & Labour T&P Etc. Painting By Asian Special Paint Etc. All Complete. (Rate Mr As Smart City, Agra) , Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes To Water Bound Macadam (22.40-53Mm) Specification Including Spreading In Uniform Thickness, Hand Packing, Rolling With 3 Wheeled Steel/ Vibratory Roller In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/ Binding Materials To Fill Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density. , Providing & Laying 5Cm. Thick B.M. Laying By Paver Finisher Bitumen Of The @3.4%Kg By Weight And Stone Grit Etc. All Complete. (20-Chapter Analysis Rate) , Providing & Laying 2.5Cm. Thick S.D.B.C. Laying By Paver Finisher Bitumen Of The 5% By Weight Etc. All Complete. (20-Chapter Analysis Rate) , Supply & Fixing M/S Iron Work Display Board Including Painting, Lettering Etc. All Complete. (None Schedule) , Providing And Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580X380x350mm With White Pvc Automatic Flushing Cistern, With Fittings, Standared Size C.P. Brass Flush Pipe, Spreaders With Union And Clamps (All In C.P. Brass) With Waste Fitting As Per Is: 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass, Including Painting Of Fitting And Cutting And Making Good Thg Walls And Floors Whereever Required: Single Half Stall Urinal With 5 Litre Pvc. Automatic Flushing Cistern. (Chapter No.24 Si.No.4A) , Supply And Fixing Of Precast Reinforced Reinforced Cement Concrete Benches (Pfrc) Ornamental Benches With 02 Year Warranty Etc All Complete. (None Scheduled) , S/L/F Supply Of 1000Mm Dia Np-3 Reinforced Cement Concrete Hume Pipe In Proper Position As Directed By E/I Including Catage Of Pipes Collars Upto 30M Distance Etc All Complete. (Chapter No.1 Si.No.31(E) ) , Reinforced Cement Concrete Work With Cement Approved Coarse Sand And 2Cm (3/4) Gauge Approved Stone Ballast In The Proportion 1:2:4 In Reinforced Cement Concrete Slab Excluding Supply Of Reinforcement And Its Bending But Including Its Fixing And Binding The Same With 24 Bwgi Binding Wire And Including Necessary Centring And Shuttering Etc. And Also Including Supply Of All Materials Labor And Tools And Plants Etc. Required For Proper Completion Of The Work. Strength Of The Concrete Shall Not Be Less Than M-150. (5-Chapter S.I. No.-284) , Supply & Fixing Granite Stone Work Display Board (Size 2.50Ft X 4.00Ft) Including Painting, Lettering Etc. All Complete. (None Schedule) , Installation Of 1.50 H.P. Isi Marked Sumbercible Pump Etc All Complete. (Attache As Per Santion Annalysis) , Cost Of Septik Tank Attache As Per Estimate & Details. , Plain Glass Best Quality, Cut To Size 5Mm Thick , Providing And Fixing Designer Dustbin (Market As Per Catlog Code No. Db-03). , Supply Of Planting Of Trees Amaltas, Jaarul, Arjun Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 110Mm Is:4984:2016 (As Per Market Rate) , Hdpe Pipes Pe100 Pn 06 Sdr 21 Dn 160Mm Is:4984:2016 (As Per Market Rate) , Supply & Fixing Of Pre-Cast Reinforced Cement Concrete Drain Cover Different Size Etc All Complete. , Supply And Sowing Of Grass In Park Including One Year Mantinance Etc. All Complete. (None Scheduled) , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 8 Km Lead Complete (Earth Measure Dinstacks Will Be Reduced By 20% For Payment) .(Dar 2020 Hort-Basic Rates 2.2) Based , Supply And Fixing Of Light, Fitting Switch Board. (None Sheduled) , Supply And Fixing Of Chest Press Double. , Supply And Fixing Of Leg Press Double. , Supply And Fixing Of Triple Twister. , Supply And Fixing Of Shoulder Builder Double. , Supply And Fixing Of Air Walker. , Supply And Fixing Of Doublebar. , Supply And Fixing Of Rower. , Supply And Fixing Of Horse Rider. , Supply And Fixing Of Plastic Side With Iron Ladder 12 Feet Length. , Supply And Fixing Of See Saw Double Board Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Sliding With Swing Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Slide Ground Level Mgr Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Snack Climber Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Slide Jhoola Etc All Complete. (None Scheduled) , Supply And Fixing Of Nursery Combo Set Revolving Jhoola Etc All Complete. (None Scheduled) , Providing And Fixing Of Stainless Steel Water Cooler 4 Tap Etc. All Complete. (None Schedule) , Supply And Fixing Bansi Paharpur (Red/White) Bharra Sand Stone Fully Moulded, Engraved, Carved With Polishing And Dressing Including Clamp And Fashners Of Pillar Set With All Complete Work Etc. (None Schedule) , Supply & Fixing Of Rubber Moulded Cement Concrete Kerb Stone (Double Tapper) M-20 With Labour T&P Etc All Complete. , Supply And Installation And Jointing Of 500Mmx500mm Epdm Rubber Mat Flooring Of Thickness 24Mm Puling All Labour Material T&P Etc. All Complete (Rate As Per Jhs Jscl Mr). , Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm/230Mm/300Mm Thick Aac Blocks In Super Structure Above Plinth Level Up T Floor Five Level With Reinforced Cement Concrete Band At Sill Level And Lintel Level With Approved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer-In-Charge (The Payment Of Reinforced Cement Concrete Band And Reinforcement Shall Be Made For Separately). , Providing And Fixing Of Barricading Of 100Mm Average Ballies With In A Distance Of 1.50 Meter For 3 Rows Of 3Q. 3 Nosof Cross Ballies, Two Supporting Ballies Of 3 Meter Ballies And 2 Nos Perpendicular Ballies Tie With Moonj Rope Including Supply Of All Material Such As Ballies Rope T&P Required For Proper Completion Of Work And Also Including Labour Component (Material Will Be Property Of Contractor After Dismantling). , Providing & Fixing Of Green/White Shade Multipurpose Net/Cotton Cloth Proper Completion Of Work Etc All Complete. (Ns) , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Supply And Fixing Of Ward Up Big As Per Attach Photograph & Analysis. , Supply And Fixing Of Ward Up Small As Per Attach Photograph & Analysis. , Supply And Fixing And Installation Of See Saw Double Board Jhoola Isi Marked As Per Direction Of Engineer-In-Charge Etc. All Complete As Per Attach Photograph & Analysis. , Supply And Fixing Of Cast Iron Banches As Per Attach Photograph And Analysis And Direction Of Engineer-Incharge Etc. All Complete. , Complete De-Silting And Cleaning Of All Types Of Sewer Lines By Using Super Suction Machine And Taking Out Of Cebris/Silt Etc Including Safe Disposal Of Silt As Directed By The Deptt. Including Cost Of All Consumble Likes Disel Oil, Water Ret Provision Of Diversion Of Line If Required With The Help Of Sewage Pumps, Poser Backup From Gene Sets For Running Of Pumps. Night Lighting Etc Barricades Display Of Entire Operation Along With Sadequate Safely Equipments Must Be Used By Sewer Workers Size Fo Sewer Line To Be Desilted As Detail Above 1000Mm Dia. , providing and laying Gsb With Graded Stone Ballast With Stone Grit Size Stone Ballast With Hand Ramming Watering Including All Material Labor T&P Etc.All Complete (Ns) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) , Providing & Laying Of Polythene Etc. All Complete. , Supply & Fixing Of Factory Wired Intergal Led Flood Light Luminaries With Die Cast Aluminum Housing Built With Driver Set Suitable For 140W. To 150W. Confirming To Ip 65 Protection Complete In All Respect. Cat Aaa ( S.I No. 1454 Pwd Schedule 2018) , Providing, Laying, Spreading And Compacting Stone Aggregates 45-63Mm Of Specific Sizes To Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing, Ro Ling With Smooth Wheel Roller 80-100 Kn In Stages To Proper Grade And Camber, Applying And Brooming, Stone Screen Ing/Bindin G Materials To Fill-Up The Interstices Of Coarse Aggregate, Watering And Compacting To The Required Density Grading 2 As Per Technical Specification Clause 405. (Labour , A Pre-Laminated Sheet, Often Referred To As A Prelam Sheet, Is An Engineered Myka Wood Work Product Where A Decorative Layer, Like Laminate Or Veneer, Is Pre-Attached To A Core Material Like Particleboard Or Mdf. These Sheets Offer A Durable And Aesthetically Pleasing Surface For Furniture, Interior Design, And Construction.(None Scheduled) , Same Is Ltme No-1 & Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured) , Treatment Of Soil Under Existing Floors Using Chemical Emulsion @ One Litre Per Hole, 300 Mm Apart Including Drilling 12 Mm Diameter Holes And Plugging With Cement Mortar 1 :2 (1 Cement : 2 Coarse Sand) To Match The Existing Floor: With Chlorpyriphos/Lindane E.C. 2Oo/O With 1% Concentration (Chapter No.8 Sr.No.6.1) , Supply And Fixing Of Advertisement Sign Board Size 4X3 As Per Direction Of Engineer-In-Charge Etc. All Complete , Supply Of Planting Of Trees Washington Palm, Amaltas, Cycus Revoluta, Ficus Benjamina Or Any Other As Per Architect Of Road Side 600X600 Dia Hole Meter Daging Road With One Years Maintenance. , Providing Of Rain Water Harvesting Drawing And Analysis Etc. All Complete (Details Attached). , Supply, Fixing And Installation Of Acrelic Led Letter In Hindi As Per Direction Of Engineer-In-Charge Etc. All Complete. , Drilling Of 200Mm Dia T/W Bore Suitable For 110Mm Dia Pipe All Complete With Labour T/P As Per Direction Of Engineer-In-Charge. , Suppply And Lowering Of 110Mm Dia 6 Kg/Cm2 Pvc Pipe (Phenolex Or Apb By E/I) All Complete. (Isi Marked Only) , Supply And Pouring Of Pea Gravel Suitable For T/W Bore All Complete. As Per Direction Of E/I (If Required) , S/L Of 1.50 H.P. Submersible Pump Set 65 Mt Head. (Pluga, Crompton, Ksb Etc.) I.S.I. Marked Etc All Complte. (Water Filled Only) , Supply & Fixing Of 100Mm Pvc Pipe Adopter Suitable For Item No.2 , S/L Of 1.50 H.P. Submersible Motor Controlled Starter Pannel All Complete. Crompton Make. (I.S.I. Marked Only) , Supply/Fixing Of 25Mm Gate Valve All Complete. Approved Make. , Supply/Fixing 4Sq.Mm 3 Core Copper Cable All Complete. , S/L Of 40Mm Dia Red Screen Ashirbad Pvc Pipe All Complete. , Supply/Fixing Of M.S. Clamp Made With 65X6mm X600mm Long M.S. Streep Suitable For 110Mm Dia Pvc Pipe For Holding All Complete. , Supply/Fixing Of 40Mm Dia G.I. Pipe B-Class Complete With Labour Charge. (Including All G.I. Fitting) , Supply & Fixing Of 25Mm Cpvc Etc. All Complete. , Development Of Bore Till The Discharge Is Free From Turbidity Of Compression Including Labour, Required For Proper Completion Of Work. , Supply And Fixing Of Precast Readymade Boundry Wall Hieght 8 Feet Etc All Complete. (As Market Rate) , Useable Brick (A) Class M-L50 , Useable Brick (B) Class M-100 , Useable Brick(C ) Straiqht Over Brunt , (D) Tiles, Bull Nose Drip Course Brick , Brick Ballast (A) Brick Ballast 40Mm Qauge , Brick Ballast (B) Class-150 Brick Ballast 25Mm Gauge , Brick Ballast (C ) Brick - Bats Of O.B.B./150 Bb , Fiy Ash Brick (Specification/Strength Should Not Be Less Than Bricks - M-{50) 230Mmx1 10Mmx75mm , Aac Block Autoclaved Aerated Concrete Block (Aac Block) Conforming To Ls : 2185 - 2005 (Part-3) Including Loading, Cartage Upto Site, Unloading, Stacking And Including All Levies And Royalties If Any But Excludinq G.S.T , Stone Ballast (Khera Thakur Quarry Bharatpur Rajsthan) 45-90 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 45-63 Mm Guage Stone Ballast. , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 22.4-53 Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 20Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) 19Mm Guage Stone Ballast , Crushed Stone Ballast/Grit (Ghatri Quarry Bharatpur Rajsthan) Crushed Stone Dust 2.36Mm & Below , Stone Dust , 13.20Mm Guage , 11.20Mm Guage , 6.7Mm Guage And Below , Stone Boulder (From Khera Thakur Quarry) (A) 25-40 Kq , Stone Boulder (From Khera Thakur Quarry) (B) 40-60 Kq , Stone Boulder (From Khera Thakur Quarry) (C) Stone Bricks Dressed , Grit {District Gwalior(Mp) Quarry}(Berja,Chandrapura, Turak Pura,Parsen,Sumerpada Padampur Kheria, Bhileti & Bilara) District Bhind (M.P.)(Pali, Dirman & Piparsana) , (A) 45-63 Mm Guage Stone Ballast. , (B) 22.4-53 Mm Guage Stone Ballast. , (C) 20-40 Mm Guage Stone Ballast. , (D) 20 Mm Guage Stone Ballast. , (E) 19 Mm Guage Stone Ballast. , (F) 16 Mm Guage Stone Ballast. , (G) 13.20 Mm Guage Stone Ballast. , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 60Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 80Mm Coloured Rubber Moulded , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Rubber Moulded Grey , I Shaped Precast Interlocking Tiles (Strength Of 30Mpa) At Site 100Mm Coloured Rubber Moulded , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 , Rubber Moulded Gement Concrete Kerb Stone M-20 12X12 X6 (Plain) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 16 X6 (Designer) , Rubber Moulded Gement Concrete Kerb Stone M-20 12X 18 X6 , Coarse Sand (Excluding Actual Bulkaqe) , Fine Sand (Excludinq Actual Bulkaqe) , (L) Local Sand , Cement (L) Portland Cement (J.P., A.C.C., Birla, J.K.) O.P.C , Cement (Ll) Cement (P.P.C.) , Cement (Lll) White Cement (J.K. Or Birla Brand) , Green Net(Chapter- 1 Sl.No 44) , Tractor Trolley With Driver Including P.O.L. (Chapter-2 Sl.No 25)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 142
Uttar Pradesh View Result →
7.
Defence #11286957 Technical Bid
Tender for Sch A Part- I To Ix: Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated As Under Col 5 Signifies This Fact Only , Total Amount Of Sch ‘A Part I (Building & Structures) , Total Amount Of Sch ‘A Part Ii (Site Clearance, Excavation & Earthwork ) , Total Amount Of Sch ‘A Part Iii (Cooling Appliances & Air-Conditioning) , Total Amount Of Sch ‘A Part Iv (Dg Set) , Total Amount Of Sch ‘A Part V (Internal Electric Supply) , Total Amount Of Sch ‘A Part Vi (Road / Path) , Total Amount Of Sch A Part-Vii (Area Drainage ) , Total Amount Of Sch A Part-Viii (External Water Supply) , Total Amount Of Sch A Part-Ix (External Electric Supply) , Schedule A Part-X (Misc B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 6 Signifies This Fact Only. Bidders Shall Insert Their Rate In Column-7 For That Purpose. , S&F Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva Complete All As Specified And As Directed By Engr-In- Charge. Makes :- Automatic Electrical (Ae)/ Vinitec/ Aplab/ V Guard , S&F Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. Makes :- Automatic Electrical (Ae)/ Vinitec/ Aplab/ V Guard/ Volina , Supply, Install, Testing And Commissioning Of Silent Diesel Engine Generating Set, 100 Kva/80 Kw, 1500 Rpm, 3 Phase, 415 V, 50 Hz, Power Supply Alternator Along With Fuel Tank, Control Panel., Battery And Complete Set Installed In Sound Acoustic Enclosure And Standard Accessories And Fittings With Power Factor 0.8, Plain Cement Concrete Foundation Suitable For The Generator Set As Per Manufacturers Instructions Complete With Standard Accessories And Microprocessor Based Integrated Dg Set Controller With Coupled To Alternator Rated At 100Kva/80 Kw At 415 Volts, Set Mounted On Channel Iron Base Frame Complete With Sub-Base With Batteries, Avm Pads And Std Panel All As Per Guideline Of Latest Cpcb Iv+ Norms All As Specified And Directed And Comprising Of The Following: , Note For Item No. 11.30 (I) Engine: Engine With Direct Injection, Water Cooled, 3 Cylinders, In-Line,4 Strokes Rated At Developing 126.8 Bhp @ 1500 Rpm For Continuous Duty Of Suitable For 100 Kva Alternator With Provision Of 10% Over Load For One Hour In Every 12 Hour Running Confirming To Bs 5514/ Iso 3046 Standard Totally Enclosed As Per Oem Specification And Directed By Engr-In-Charge. The Engine Has The Following Specification:- A) Mechanical Fip B) Mechanical Governor C) Turbocharger, Exhaust Manifold, Stainless Steel Exhaust Flexible Connection D) Radiator Cooled, With After Cooled E) Plate Type Lube Oil Cooler F) Filters G) Lube Oil H) Dry Type Replaceable Paper Element Air Cleaner J) Flywheel Housing And Flywheel To Suit Single Bearing Alternator K) Starting Motor-Electric, Battery Charging Alternator L) First Fill Lube Oil And Coolant (Ii) Alternator: Brushless Alternator, Self -Excited, Self -Regulated, Floor Mounted With All And / Or Roller Bearings, Statically And Dynamically Balanced Screen Protected Acoustic Enclosure Confirming To Is 4722 / Is 13364, Ip-23 Protection With H Class Insulation Limited Temperature Rise Of Class H, Automatic Voltage Regulator From No Load To Full Load, Ammeter Capacity Of Delivery 100 Kva, 415 Volts, 3 Phase, 50 Hz And Lagging For Ac Supply And Will Be Suitable For Tropical Conditions All As Per Oem And Directed By Engr-In-Charge. (Iii) Instrument Panel : Engine Instrument Panel Consisting Of On/Off Starting Switch With Key Lubricating Oil Pressure Gauge, Water Temperature Gauge, Battery Charging Indicating Lamp, Hour Meter With Rpm Indicator, Safety Control Against High Temperature Of Water, Over Speed Stop With Double Driver Adopter As Per Oem Specification And Directed By Enge-In-Charge. (Iv) Other Fittings: (A) Battery Charger : Battery Charger Having Electric Circuit Consisting Of Rectifiers, Capacitors And Resistance Etc. The Battery Charger Should Be Able To Charge 12 Volts 88 Ah Battery At A Time (V) Dg Set Shall Be Supplied Along With Acoustic Original Enclosure Of The Manufactures Suitable For 100 Kva Dg Set And All Connecting Accessories As Per Latest Cpcb Iv+ Norms , (Vi) The Diesel Oil, Lub Oil Etc. For Smooth Functioning Of Dg Set During Ph-I & Ph-Il Complete Testing And Full Tank Filing Of Diesel Oil After Ph-I & Ph-Ii Testing, Topping Of Lub Oil Etc. Required For Commissioning And Testing Of Dg Set. (Vii) Amf Panel: - Supply Installing Commissioning & Testing In Microprocessor Based Amf Panel Board Factory Made, Out Door Type Ip-65, Cubical Type, Vermin Proof, Dust Proof, Water Proof Made Out Of 3.15 Mm Thick Crca Sheet And Angle Iron Frame Of Size 50X50x6 Mm Inside Depth Not Less Than 50 Cm And Size Suitable To Accommodate The Following Accessories With Insulated Tpn Copper Busbar Of Rating Not Less Than 1.5 Times The Rated Capacity Of The Incomer Mccb Suitable For 100Kva Dg Set. Hinged Door With Locking Arrangement Duly Painted With Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Both Internally And Externally And Connecting With Cable With Lugs Including Internal Wiring With Copper Cable Of Suitable Size Using Lugs Compressing The Following Accessories All As Directed. (Notes : The Rate Quoted Shall Include For Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ) And Copper Bus Bar 240 Amps Duly Colour Sleeved Mounted On Epoxy Insulators-01 Set. Note:(I) Amf Panel Suitable For 100 Kva Dg Set To Connect With Grid Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. The Amf Panel Has The Following Specification:- A) 160A, 4 Pole Contactor For Alternator With Thermal Over Load Relay B) 160A, 4 Pole Contactor For Mains C) Mcb For Short Circuit Protection D) Indication Led (Dg On, Load On Dg, Main On, Load On Main, Battery Charge On) E) Push Buttons (Engine Start/Stop, Generator Contactor Close/Trip, Main Contactor Close/Trip If Provided, Fault Accept/Reset) F) Voltmeter & Ammeter And Other Connecting Accessories And Safety Features For Successful Auto Operation Of 100 Kva Dg Set. (Viii) Excavation, Earthwork And Provn Of Plain Cement Concrete Plinth Of Suitable Sizes For Installation Of Dg Set & Connected Accessories Complete As Per Oem/ Site Requirements. , S&F Square Profile Led Lighting Fixture With Extruded Polycorbonate, Environmental Friendly, Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output, With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. Make:Havells Led Pride Essential Cat No Lhexawp7un1w020 Or Equivalent Makes Cg/Philips/Wipro/Luker. , S&F Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb As Incomer Ip43 Protection Double Door: Plain 6 Way With Suitable Rated Busbar, Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separately. , S&F Mccb 4 Pole, 415 V, Adjustable Type Thermal Magnetic Release, 125 Amps With Breaking Capacity 25 Ka And Making Connection With Suitable Size Of Copper Lugs Etc Complete All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24,450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 50 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24,450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed , M&L For Cutting Of Existing 40 Mm Dia Pipe For Inserting Tee Of Size 40X40x20 Mm Including Lead Joint And Excavation Etc Complete, All As Specified And As Directed , Supply, Install, Testing And Commissioning, Factory Made And Tested (Including Cpri Type Test Certified) Lt Panel Board Out Door Type, Floor Mounted, Compartmentalised And Ip-63 Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, All As Specified And Directed, Having Bus Bar Chamber With Insulated Aluminium Bus Bars 250 Amps Rating Installed On Porcelain Insulators. The Panel Shall Be Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet And With Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Front And Rear Opening Type With Aprons For Cable Entry With Double Door Shutter And Locking Arrangement With And Including Following Items. (Notes : The Rate Quoted Shall Include Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ).Note: Panel Board Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. Incoming :- (A) Mccb 4 P, 415 Volt 160 Amps, 32Ka, 50 Hz With Fixed Thermal And Magnetic Setting -01 No Outgoing :- (B) Mccb 4 P, 415 Volt 125 Amps, 25Ka, 50 Hz -01 Nos. (C) Mccb 4 P, 415 Volt 63 Amps, 10 Ka, 50 Hz -02 Nos. (D) R,Y,B Indicators (E) Multifunction Digital Square Type Intelligent Panel Meter To Measure Voltage, Current, Frequency, & Power Factor - 01 No
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 13
Maharashtra View Result →
8.
Public Administrative Department #11286668 AOC
Tender For Construction/Repair Work In Record Room/Nazarat Department - (a) Bricks M-150 2 (b) Bricks M-100 3 (c) Bricks-Straight over brunt 4 (d) Bricks- Tiles (Ist Class) 5 (e) Brick Bats M-75 6 (f) Brick Bats (O.B.) 7 Fly ash Bricks (specification/strength should not be less then Bricks M-150)size 230x110x75mm 8 Fly ash Bricks Tiles (specification/strength should not be less then Bricks M-150)size 230x110x38mm 9 Fly ash Concrete curve Stone (specification/strength should as per mord/morth) size 300x300x150mm (M30) 10 (a) 5.00cm. Gauge 11 (b) 4.00 cm. gauge 12 (c) 2.50 cm. gauge 13 Stone Grading Materials Aggregate - For 37.5 mm Maximum size - 22.4 mm to 5.6 mm 14 Aggregate - For 37.5 mm Maximum size - 45 mm to 22.5mm 15 Aggregate - For 37.5 mm Maximum size - Below 5.6 mm 16 Aggregate - For 53 mm Maximum size - 22.5 mm to 5.6mm 17 Aggregate - Grading I (40 mm nominal Size) 10 mm - 5 / 4.75 mm 18 Aggregate - Grading I (40 mm nominal Size) 25 mm – 10mm 19 Aggregate - Grading I (40 mm nominal Size) 37.25 mm -25mm 20 Aggregate-Grading I 90 mm to 45 mm 21 Aggregate-Grading II 63 mm to 45 mm 22 Aggregate-Grading III 53 mm to 22.4 mm 23 Aggregates 22.4 mm to 2.36 mm for wet mix macadam 24 Aggregates 45 mm to 22.4 mm for wet mix macadam 25 Crushed Sand or Grit Passing 2.36 mm and retained on 180 micron 26 Crushed Stone Aggregate 26.5 mm to 75 micron 27 Crushed Stone chipping 13.2 mm nominal size 28 Crushed Stone Chipping 6.7 mm size 100% passing 11.2 mm and retained on 2.36 mm 29 Crushed Stone Chipping 6.7 mm size 100% passing 9.5 mm and retained on 2.36 mm 30 Crushed Stone chipping 9.5 mm nominal size 31 Crushed Stone Coarse Aggregate Passing 53 mm and retained on 2.8 mm 32 Fine aggregate/Crushed sand 2.36 mm to 75 micron 33 Stone Boulder of size 150 mm and below 34 Stone for Coarse Rubble Masonry 1st Sort 35 Stone for Coarse Rubble Masonry 2nd Sort 36 Stone for Random Rubble Masonry 37 Stone for Stone Set Pavement (300 mm x 200 mm x 150MM 38 Well Graded Material for Sub-Base - Grading I 2.36 mm below 39 Well Graded Material for Sub-Base - Grading I 53 mm to 9.5 mm 40 Well Graded Material for Sub-Base - Grading I 9.5 mm to 2.36 mm 41 Well Graded Material for Sub-Base - Grading II 2.36 mm below 42 Well Graded Material for Sub-Base - Grading II 26.5 mm to 9.5 mm 43 Well Graded Material for Sub-Base - Grading II 9.5 mm to 2.36 mm 44 Well Graded Material for Sub-Base - Grading III 2.36 mm below 45 Well Graded Material for Sub-Base - Grading III 4.75 mm to 2.36 mm 46 Well Graded Material for Sub-Base - Grading III 9.5 mm to 4.75 mm 47 Boulder with minimum size of 300 mm for Pitching at Site 48 Granular Material or hard murrum for GSB works at Site 49 Close graded Granular sub-base Material 37.5 mm to 9.5 mm 50 Close graded Granular sub-base Material 9.5 mm to 4.75 mm 51 Close graded Granular sub-base Material 4.75mm to 75 micron mm 52 Close graded Granular sub-base Material 2.36 mm 53 Coarse graded Granular sub-base Material 4.75mm to 75 micron mm 54 Coarse graded Granular sub-base Material 4.75 mm to 2.36 mm 55 Coarse graded Granular sub-base Material 9.5 mm to 4.75 mm 56 Coarse graded Granular sub-base Material 26.5 mm to 4.75 mm 57 Coarse graded Granular sub-base Material 26.5 mm to 9.5 mm 58 Coarse graded Granular sub-base Material 37.5 mm to 9.5 mm 59 Coarse graded Granular sub-base Material 53 mm to 26.5mm 60 Stone screening material for WBM Grading-2 and 3 61 Miscellaneous Items Cement Grey PPC 62 Cement Port land (ordinary) 63 Cement white viz J.K./Birla 64 Wall Putty J.k / Birla white 65 Plaster of Parish Sakarni or eqvivalent 66 Cinder 67 Distemper oil bound 68 Dry Distemper ordinary of bes quality (Approved manufacture and approved quality viz. Burger, Asian, J&N 69 Glass Ordinary cut to size (a) 3mm thick (Wt. 7.5 Kg./sqmt.) 70 (b) 4mm thick (Wt. 10.0 Kg/sqmt.) 71 (c) 5.5 mm thick (Wt. 13.5 Kg/sqmt.) 72 White lime (unslacked) for White Washing 73 White Lead (Best Quality PIG Lead) 74 (d) G.I. Barbed wire 75 (e) Iron Sheet Galvanized Plain 22 gauge 76 (f) Iron Sheet Galvanized Plain 24 gauge 77 (g) -do- but corrugated 24 gauge 78 (h) -do- but black plain 18 gauge 79 (J) Expanded metal 2-0 cm mesh 16/17 guage 80 (K) M.S. binding wire 24 gauge 81 (i) 1x2 size of 10 gauge wire 82 (ii) 1x3 size of 10 gauge wire 83 (iii) Murga Jali 1/2x24 gauge 84 (iv) 1x2 size of 10 gauge wire 85 (i) F -d sections @ 1.58 Kg/R/M 86 (ii) F -B/T/T Secs. @ 2.40 Kg/R/M 87 (iii) F - Sections @ 0.74 Kg/R/M 88 (a) Super white 89 (b) Commercial white, coloured & black 90 Marble Dust (200 mesh) 91 Nails (Country) 92 Nails (Wire) 93 (a) Oil (linseed double boiled) 94 (b) Oil (Terpentine) 95 (a) Paint anticorosive Bitumenous 96 (b) Black Japan 97 (c) Superior Ready Mixed paints (Grade II) in 20 ltrs. Drums of approved manufactures and aporoved make 98 (i) Dark Green Oxide 99 (ii) Deep Black Oxide 100 (iii) Blue Oxide 101 (iv) Chocoiate Oxide 102 (e) (i) Red Oxide primer surface for steel (in 20 ltrs. Drum) (Approved manufactures and approved make) 103 (ii) Red lead paint ready mixed for roof (in 20 ltrs. Drum) (Approved manufactures and approved make) 104 (f)(i)PaintenamelGradeIsuperClass(Approved manufactures and approved make) 105 (ii) Paint (Aluminium) 106 (g) (i) Paint primer for wood 107 (ii) Paint primer for metal 108 (h) (i) Cement Primer of Berger or equivalent 109 (ii) Water proof cement paint (in 50 kg. drums) 110 (i) Clear synthetic (in 20 ltr drums) 111 (ii) Copall 112 (iii) Weather Coat cement paint for exterior 113 (iii) Weather Coat cement paint for exterior 114 Water Proofing compound (Dr. Fixit) 115 Polish (mansion & wax) 116 (iv) P.V.C. Pipe 110 mm dia & 6Kg./CM2 (ISI Marked) 117 (v) Same as above but 90 mm dia 118 (vi) Same as above but 75 mm dia 119 (v) Same as above but 140 mm dia 120 (a) Corrugated 121 (b) Plain 122 (i) Internal dia 5 cm (Wt. 11.41 Kg.) 123 (ii) Internal dia 7.5 cm. (Wt. 16.52 Kg.) 124 (iii) Internal dia 10 cm. (Wt. 21.67 Kg.) 125 (iii) Internal dia 15cm. (Wt. 21.67 Kg.) 126 (i) 5.0 cm dia (Wt. 2.30 Kg. ) 127 (ii)7.5 cm dia (Wt. 3.30 Kg.) 128 (iii) 10.0 cm. dia (Wt. 4.60 Kg.) 129 (i) 5.0 cm dia (Wt. 2.10 Kg. ) 130 (ii) 8.0 cm dia (Wt. 3.20 Kg.) 131 (iii) 10.0 cm. dia (Wt. 4.40 Kg.) 132 (c) C.I. Spout 23.0 cm Long 40 mm dia 133 (a) Rope (Moonj) 134 (b) Rope (HEMP) 135 (c) Rope (cotton) 136 (d) Spun yarn 137 Rivets 138 Coarse sand of approved quarry (Finess modules 2.20) at site of work in the district Saharanpur, Muzaffarnagar 139 Finesand(blendedtofineness modulus1.25) Saharanpur, Muzaffarnagar and Shamli 140 (a) Local Sand 141 Surkhi 142 White lime (slacked) 143 (a) Washers (Lumpet) 144 (b) Washers (Bitumen) 145 (c) Washers G.I. 146 J.Hooks 147 Wood presevator in 5 ltrs. Pack. 148 (a) Teak wood 149 (b) Sheesham 150 (c) Indian Sal 151 (a) Teak wood 152 (b) Sheesham 153 (c) Indian Sal/ maleshien 154 Fuel Wood (Dry) 155 (a) 2.2 cm width 156 (b) 3.50 cm. width 157 (c) Same as 48 (a) but 5 mm thick 158 (d) Same as 48 (b) but 5 mm thick 159 Antitermite treatment oil concentrate to 0.30 (as per IS 1307) 160 (i) 40mm thick 161 (ii) 50 mm thick 162 (a) KOTASTONE (machine cut ) 60 x 60 cm. 163 (a) Marble White 60 x 60 cm. 164 (b) Marble White 60 x 60 cm. 165 Granite stone black or Grey Polished 166 Granite stone black or Grey Polished 167 Polythene Sheet (125 Micron) 168 Plastic waste which is cleaned is cut into a size between 2.36mm and 600 microns and of maximum size 2.36 mm length and 2.00mm width. 169 (a) For Floor Size 300 x 300 170 (b) For Wall Size 200 x 300 171 (c) Vitrified Tiles size 600 x 600 172 RCC Hume Pipe 350mm dia 173 RCC Hume Pipe 450mm dia 174 (a) Ordinary 175 (b) For floor and tile work 176 Carpenter 177 Black Smith 178 Hammer man 179 Fitter 180 Painter 181 (a) Plumber Licensed with Kit or Koshal vikash CERTIFICATE 182 (a) Plumber Licensed with Kit or Koshal vikash CERTIFICATE 183 (b) Electrician Licensed with Kit or Koshal vikash certificate 184 (b) Electrician Licensed with Kit or Koshal vikash certificate 185 Mate 186 Beldar / Mali 187 Bhishti with Mushk 188 White Washer 189 Belder for bitumen or tar work 190 Glazier 191 Bhainsa Buggi with driver 192 Tractor trolley with driver excluding P.O.L. 193 Amin/Tracer 194 Chaukidar 195 Jeep/Truck/Tractor/Roller Driver 196 Generator Operator 197 Mixol Operator 198 Pump Operator 199 Cleaner 200 Sweeper (Full Time) 201 Sweeper (Part Time) 202 Tractor with harrow or water TankerTrolly with 203 Tractor with harrow or water TankerTrolly with 204 driver and P.O.L. 205 J.C.B. Machine with driver with P.O.L. 206 Crane (20-50 Tonnee) with Driver and P.O.L. 207 Ricksaw Thela with Driver 208 (a) Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 M. and lead upto 30 M. and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in charge upto a distance of 30 M. from the foundation trenches. (where machine can not move ) 209 (a) As in item 251 (a) above but excavation in soil mixed with Moorum, shingle, kankar requiring the use of special tools and plant such as pickaxes, sabbals etc. (where machine can not move ) 210 (a) Earth work in cutting or in embankment in ordinary soil excavation to be in the form of regular pits not exceeding 0.50 M. in depth and earth work in embankment to be in 20 cm. layers including remming and dressing the surface to required levels and slopes and also including 1.50 M. lift and 30 M. lead. The earth from cutting to be used in making embankment or to be deposited as spoil banks with-in 30 M. distance as directed by the Engineer incharge. (Royality removed by Govt. ) for small works/ Abadi area. (where machine can not move ) 211 (a)Add to items (251-253) for every additional 30 M. (100 ft.) lead or part of 30 M (100 ft.) or for every additional 1.50 M. (5 ft.) lift or part of 1.50 M. (5 ft.) 212 (a) Sand filling in plinth and under floor including supply of necessary quantity of sand from a distance not exceeding 8 Kms. from the site of work and including watering, dressing etc. labour and T&P etc. required for proper complition of the work. saplings of girth upto 30 cms. measuredat a height of 1 M. above ground level and removal of rubbish upto a distance of 50 M. out side the periphery of area cleared. including cost of sand. 213 (i) Cleaning jungle including up rooting ofrank, vegetations grass, push, wood trees and amplings of grith upto 30 cms. measured at a height of 1 M. aboveground level and removal of rubbish up to a distance of 50M. out side the periphery of area cleared. 214 (a) Same as above 259(i) above but grass only. 215 (a) Add to item no. 253 (a) for mechanically compected to achieve 95% proctors density including arrangement of water, settlement and all T&P including roller and its fuel etc. 216 (b) As in item no. 260 (a) above but for departmental works excluding Roller charges and its fuel, cost of water, allT&P. and sundries etc. but including carriage of water to site. 217 Upto ½ Km 218 Ist Km. (If lead is beyond ½ Km.) 219 Concrete with 4 cm. guage brick ballast, white lime and surkhi in foundation and under floors in the proportion of 100:16:32 including supply of all materials, labour Tools & plants etc. required for proper completion of the work. 220 Concrete with 4 cm. gauge brick ballast, Fine sand of 1.25 F.M. and cement, in proportion of 12:6:1 in foundations and under floors, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 221 As in item 273 above but in proportion 10:5:1 222 As in item 273 above but in proportion 8:4:1 223 (a) Same as above item no. 279 but with 2 cm. gauge stone grit instead of 4 cm. gauge 224 (b) Same as item no. 279 (a) but in proportion of 1:3:6 225 As in item 279 above but in proportions of 8:4:1stone Ballast, Coarse sand and cement. 226 Concrete with 4 cm. guage brick ballast, white lime and surkhi in foundation and under floors in the proportion of 100:16:32 including supply of all materials, labour Tools & plants etc. required for proper completion of the work. 227 Concrete with 4 cm. gauge brick ballast, Fine sand of 1.25 F.M. and cement, in proportion of 12:6:1 in foundations and under floors, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 228 As in item 273 above but in proportion 10:5:1 229 As in item 273 above but in proportion 8:4:1 230 (a) Same as above item no. 279 but with 2 cm. gauge stone grit instead of 4 cm. gauge 231 (b) Same as item no. 279 (a) but in proportion of 1:3:6 232 As in item 279 above but in proportions of 8:4:1stone Ballast, Coarse sand and cement. 233 Same as item no. 302 (B) above but in 1:6 (One cement & six fine sand of 1.25 F.M.) mortar. 234 Same as item no. 302 (B) but in 1:5 (One cement & five fine sand of 1.25 F.M.) mortar 235 Same as item no. 302 (B) but in 1:4 (One cement & four fine sand of 1.25 F.M.) mortar. 236 (a) Same as item no. 302 (B) but in 1:4 (One cement & four Corse sand) mortar. 237 Same as item no. 302 (B) but in 1:3 (One cement & three fine sand of 1.25 F.M.) mortar. 238 Same as item no. 302 (B) but in 1:3 (One cement & three coarse sand) mortar. 239 As in item 302 (B) to 307 above but in superstructure including necessary Cutting & moulding of bricks as required thickness of walls not to be less than 1½ brick. Add extra labour to above items. 240 As in item 309 above but for walls of one brick thick, add for extra labour 241 As in item 309 above but for walls of Half brick thick, add for extra labour to the rate of item no. 309. 242 Same as item no. 302 (B) above but in 1:6 (One cement & six fine sand of 1.25 F.M.) mortar. 243 Same as item no. 302 (B) but in 1:5 (One cement & five fine sand of 1.25 F.M.) mortar 244 Same as item no. 302 (B) but in 1:4 (One cement & four fine sand of 1.25 F.M.) mortar. 245 (a) Same as item no. 302 (B) but in 1:4 (One cement & four Corse sand) mortar. 246 Same as item no. 302 (B) but in 1:3 (One cement & three fine sand of 1.25 F.M.) mortar. 247 Same as item no. 302 (B) but in 1:3 (One cement & three coarse sand) mortar. 248 As in item 302 (B) to 307 above but in superstructure including necessary Cutting & moulding of bricks as required thickness of walls not to be less than 1½ brick. Add extra labour to above items. 249 As in item 309 above but for walls of one brick thick, add for extra labour 250 As in item 309 above but for walls of Half brick thick, add for extra labour to the rate of item no. 309. 251 Teak wood wrought framed and fixed including simple mouldings, straight work as in chaukhats including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 252 As in item No. 401 but for sheesham wood 253 As in item no. 401 but with Indian Sal wood 254 Supply & fixing of 4.5 Cm. thick teak wood part panelled and part glazed door and window shutter including supply & fixing of wooden cleats and stops and including fixing & adjustment of hinges, bolts, locks, handles spring and or other fittings but excluding their supply and including painting with two coats of black Japan on all iron fitting if necessary. Including fixing the glass panes with putty for bradglass and glass to be 4 mm. thick. Fitting with necessary screws to be supplied by the deptt. 255 Providing and fixing Glass panes with teak wood beading in doors and windows as desired by the Engineer incharge including cost of all materials, fittings, hinges, labour, T&P all etc. required for proper completion of the work. 256 As in item no. 409 above but fully panelled. 257 As in item no 409 above but fully glazed. 258 As in item no. 409 above but 3.8 cm. thick. 259 As in item no. 411 above but 3.8 cm. thick. 260 As in item no. 412 above but 3.8 cm. thick. 261 As in item no. 409 above but 3.8 cm. thick, Shisham wood. 262 As in item no. 411 above but 3.8 cm. thick, Shisham wood. 263 As in item no. 412 above but 3.8 cm. thick, Shisham wood. 264 Supply and fixing of 3.8 cm. (1½) thick Teak wood door and window shutters with panels of heavy Quality galvanized iron wire gauge 2.5 mm. or 2 mm. or 1.5 mm. (1/10 or 1/12 or 1/16 inch) mesh or any other size, with necessary beadings, including supply and fixing of wooden cleats stops and including fixing & adjustment of hinges, bolts, locks, handles spring and or other fittings but excluding their supply and including two coat of black Japan on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally. 265 As in item (450) above but in shisham wood. 266 Supply and fixing Galvanized Mosquitos proof heavy quality S.S.Wire gauge heavy quality over windows and including supply of teak wood batten 8 cm.x1.cm. (3x3/8)/flat iron 25 mm.x4mm. and including supply of necessary screws all materials, labour, Tools & plants etc. required for proper completion of the work. 267 As in item (455) above but with shisham wood battens. 268 As in item (455) above but with Indian Salwood battens. 269 As in item (455) above but with Deodar wood battens. 270 As in item no. 409 but Indian Commercial flush shutters 35 mm. thick (excluding cost of all fitting). 271 As in item no. 409 but Indian Commercial flush shutters 32 mm. thick (excluding cost of all fitting). 272 As above 471 but Double Leaf Add. extra. 273 Approximate cost of ISI marked oxidized iron fitting with screws for door & windows etc. (for estimating purpose only) 274 As above item no. 473 Aluminium Fittings ISI marked. 275 Supply and fixing of 3.8 cm. (1½) thick country wood door fully panelled shutters including supply and fixing of wooden cleats stops and including fixing & adjustment of hinges, bolts, locks, handles spring and or other fittings 276 Supply and fixing 2.5 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fitting and glass panes (Double Leaf) 277 As in item no. 9.26 above but for single leaf. 278 Providing and fixing 12 mm thick and 100 mm. wide Ply board of plywood pelmet with 19 mm. dia Al. rod and brackets including fixing with 25x3mm. M.S. flat 10 cm (4) long and plug etc. complete with painting, polishing or oiling as required. 279 Supply and fixing of 3.2 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fittings and glass panes (Double Leaf) 280 As in item no. 9.29 above but for single leaf. 281 Supply and fixing of 2.5 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fittings and glass panes (Single Leaf) 282 Suppy and fixing of Teak wood batton for fixing of mosquito net and fixing of glass & over chouket at window/door. Inculding cost of all matrial, labour & T&P etc. complete. 283 As per item above A but with shisham wood batton 284 Fixing of Jali / glass in doors/windows in small area upto 1.00 sqm (Labour only) 285 Fixing of Curtain rods (Labour only) 286 Fixing of Curtain palmets (Labour only) 287 50x20 mm 288 50x12 mm 289 With 2nd class teak wood beading 62X19 mm. 290 300x16 mm 291 250x16 mm 292 250x10 mm 293 200x10 mm 294 150x10 mm 295 Providing and fixing 12 mm thick and 100 mm. wide Ply board of plywood pelmet with 19 mm. dia Al. rod and brackets including fixing with 25x3mm. M.S. flat 10 cm (4) long and plug etc. complete with painting, polishing or oiling as required. 296 Supply and fixing of 3.2 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fittings and glass panes (Double Leaf) 297 As in item no. 9.29 above but for single leaf. 298 Supply and fixing of 2.5 cm thick fully glazed laminated window-shutter of Commercial quality ISI marked plywood including cost of fittings and glass panes (Single Leaf) 299 Suppy and fixing of Teak wood batton for fixing of mosquito net and fixing of glass & over chouket at window/door. Inculding cost of all matrial, labour & T&P etc. complete. 300 As per item above A but with shisham wood batton 301 Fixing of Jali / glass in doors/windows in small area upto 1.00 sqm (Labour only) 302 Fixing of Curtain rods (Labour only) 303 Fixing of Curtain palmets (Labour only) 304 50x20 mm 305 50x12 mm 306 With 2nd class teak wood beading 62X19 mm. 307 300x16 mm 308 250x16 mm 309 250x10 mm 310 200x10 mm 311 150x10 mm 312 250x10 mm 313 200x10 mm 314 150x10 mm 315 100x10 mm 316 125 mm 317 100 mm 318 75 mm 319 Providing and fixing aluminium tee channels (heavy duty) with rollers, stop end in pelmets as curtain rod. 320 Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71 mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI C sections (39mm x 19mm x O.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric L corners .The panel shall be filled with 3mm thick high - pressure compact laminate asper manufacturers specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). 321 With decorative veneering on one side and commercial veering on other side. 322 With non decorative veneering on both sides. 323 M.S. or iron work of small sizes and section such as holding down bolts, hold fast, tie rods grating etc. wrought to required from including supply of steel bolts, nuts wastage etc. and their fixing required for proper completion of the work. 324 Same as in item 502 above but in M.S. Grills / Stair case railing / gates / trusher / racks etc. 325 Same as in items 502 above but steel Z Section window excluding Glass panes. (i) Fixed panels 326 Same as in items 502 above but steel Z Section window excluding Glass panes.(ii) Openable panels 327 Same as in item 502 above but in heavy sizes such as trusses, built up gates, record racks, roof work, Gates etc. including rivetting or welding where necessary. 328 Boring holes in mild steel or iron not exceeding 10mm (3/8) diameter and thickness of plate not exceeding 6mm (1/4) 329 As in item (509) above but holes exceeding 10mm (3/8) diameter but not exceeding 20mm and thickness exceeding 6mm but not exceeding 13mm (1/2) 330 Providing and fixing 100mm (4) diameter C.I. Down pipe BC or equivalent make complete with bends with eye hole, plain bend shoes and gratings etc., fixed to walls with suitable clamps as directed by the Engineer-in-charge (C.I. pipe of 1.80 Meter length shall be of 20-21 Kg.) 331 Mild steel or iron work in purlins and rafters including drilling holes and fixing in position and including supply of all steel and bolts and nuts, wastage, labour and tools and plant etc. required for proper completion of work (No material shall be issued by deptt.) 332 Providing barbed iron wire fencing including fixing it to post after stretching it including labour and T&P etc. required for proper completion of the work but excluding cost of posts & barbed wire. (labour rate only) 333 with frame of 40x40x6mm (1½x1½x¼) angle iron 3.15 mm (1/8) thick M.S. gus set plate at the junction and corners including supply and fixing of necessary fittings. Lock rail of 15 length of oxidised iron and including pintels hooks at the top and applying priming coat of red lead paint on all sides complete. 334 As per item no 517a but with steel strip inplace of angle iron. 335 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm (3/4x3/8x1/12) and braced with flat form diagonals 20x5mm (3/4x3/16) size with top and bottom rails or T-iron 40x40x6mm (1½x1½x1¼) with 38 mm dia steel pullys with bolts, nuts locking arrangement, stoppers handles complete including applying a priming coat of approved lead paint. 336 Providing and fixing 1mm thick M.S. sheet sliding shutters with frame and diagonal braces of 40x40x6mm (1½x1½x¼) angle iron 3.15mm (1/8) gusset plates at the junctions and corners, hooks at top 25mm (1) dia pulleys at bottom, 40x40x6mm (1½x1½x¼) angles and T iron guides at top and bottom respectively including locking arrangement with handles etc. Complete and applying one priming coat of approved lead paint (No material shall be issued by deptt.) 337 Supplying and fixing rollingSHUTTERS of approved make made 80x125mm (3x5) cold rolled M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs. 338 Providing and fixing 27.5cm long wire spring grade 2 for rolling shutters. 339 providing and fixing top cover for rolling shutters 2.50 meter wide. 340 Providing and fixing ball bearing for rolling shutters. 341 (a) Shutters above 11.2 m² (120sqft) but upto 16.8m² (180 sqft) area 342 (b) Shutters above 16.8m² (180 sqft) area 343 (i) Door chaukhat 344 (ii) window chaukhat 345 (iii) Ventilator chaukhat 346 (iv) Stair case Nosing 347 Fixing of Main Gate / Steel Sutter /Garrage Gate etc. 348 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: profile B 349 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: profile C 350 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: profile E 351 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer on M.S. tube 12 SWG 352 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting and same with necessary stainless steel nuts and bolts complete, including fixing the rialing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer- in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, botls, fastners etc.) 353 M.S. or iron work of small sizes and section such as holding down bolts, hold fast, tie rods grating etc. wrought to required from including supply of steel bolts, nuts wastage etc. and their fixing required for proper completion of the work. 354 Same as in item 502 above but in M.S. Grills / Stair case railing / gates / trusher / racks etc. 355 Same as in items 502 above but steel Z Section window excluding Glass panes. (i) Fixed panels 356 Same as in items 502 above but steel Z Section window excluding Glass panes. (ii) Openable panels 357 Same as in item 502 above but in heavy sizes such as trusses, built up gates, record racks, roof work, Gates etc. including rivetting or welding where necessary. 358 Boring holes in mild steel or iron not exceeding 10mm (3/8) diameter and thickness of plate not exceeding 6mm (1/4) 359 As in item (509) above but holes exceeding 10mm (3/8) diameter but not exceeding 20mm and thickness exceeding 6mm but not exceeding 13mm (1/2) 360 Providing and fixing 100mm (4) diameter C.I. Down pipe BC or equivalent make complete with bends with eye hole, plain bend shoes and gratings etc., fixed to walls with suitable clamps as directed by the Engineer-in-charge (C.I. pipe of 1.80 Meter length shall be of 20-21 Kg.) 361 Mild steel or iron work in purlins and rafters including drilling holes and fixing in position and including supply of all steel and bolts and nuts, wastage, labour and tools and plant etc. required for proper completion of work (No material shall be issued by deptt.) 362 Providing barbed iron wire fencing including fixing it to post after stretching it including labour and T&P etc. required for proper completion of the work but excluding cost of posts & barbed wire. (labour rate only) 363 Providing and fixing 1mm thich M.S. Sheet door with frame of 40x40x6mm (1½x1½x¼) angle iron 3.15 mm (1/8) thick M.S. gus set plate at the junction and corners including supply and fixing of necessary fittings. Lock rail of 15 length of oxidised iron and including pintels hooks at the top and applying priming coat of red lead paint on all sides complete. 364 As per item no 517a but with steel strip inplace of angle iron. 365 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm (3/4x3/8x1/12) and braced with flat form diagonals 20x5mm (3/4x3/16) size with top and bottom rails or T-iron 40x40x6mm (1½x1½x1¼) with 38 mm dia steel pullys with bolts, nuts locking arrangement, stoppers handles complete including applying a priming coat of approved lead paint. 366 Providing and fixing 1mm thick M.S. sheet sliding shutters with frame and diagonal braces of 40x40x6mm (1½x1½x¼) angle iron 3.15mm (1/8) gusset plates at the junctions and corners, hooks at top 25mm (1) dia pulleys at bottom, 40x40x6mm (1½x1½x¼) angles and T iron guides at top and bottom respectively including locking arrangement with handles etc. Complete and applying one priming coat of approved lead paint (No material shall be issued by deptt.) 367 Supplying and fixing rollingSHUTTERS of approved make made 80x125mm (3x5) cold rolled M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs. 368 Providing and fixing 27.5cm long wire spring grade 2 for rolling shutters. 369 providing and fixing top cover for rolling shutters 2.50 meter wide. 370 Providing and fixing ball bearing for rolling shutters. 371 (a) Shutters above 11.2 m² (120sqft) but upto 16.8m² (180 sqft) area 372 (b) Shutters above 16.8m² (180 sqft) area 373 (i) Door chaukhat 374 (ii) window chaukhat 375 (iii) Ventilator chaukhat 376 (iv) Stair case Nosing 377 Fixing of Main Gate / Steel Sutter /Garrage Gate etc. 378 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B 379 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C 380 Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E 381 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer on M.S. tube 12 SWG 382 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding grinding, buffing, polishing and making curvature (wherever required) and fitting and same with necessary stainless steel nuts and bolts complete, including fixing the rialing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer- in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, botls, fastners etc.) 383 Struck pointing with cement mortar consisting of 1 part cement and 2 parts of fine sand of 1.25 Fineness modulus. 384 Same as in item 574 above but Flush pointing Deduct from item 574. 385 Same as in item 574 above but in floors deduction from item 574 & 575. 386 Struck cement pointing with 1:2 cement and fine sand of 1.25 F.M. mortar with colouring including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 387 12 mmthick plaster with cement and fine sand of 1.25 fineness modules in 1:3 over brick work minimum thickness not to be less than 1cm. including supply of all materials, labour, tools & plants etc. required for proper completion of the work. 388 As in item (582) above but with cement and approved coarse sand mortar in 1:3. 389 As in item (582) above but with cement and fine sand of 1.25 fineness modules mortar in 1:4. 390 As per Item No. 584 but with 1:4 cement and Corse sand 391 As in item (582) above but with cement and fine sand of 1.25 fineness modules mortar in 1:6. 392 Add for extra labour to all item of plaster if done ceiling. 393 Add for extra labour and materials for plaster over rough face of one brick wall. 394 2 cm. thick cement plaster in dado or skirting in 1:2 consisting of one part of cement & two parts of approved coarse sand laid in panels finished with 3 mm floating coat of neat cement or cement mixed with marble dust in ratio 5:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 395 Same as above item but 1.20cm. thick instead of 2 cm thick. 396 Engraving lines in plaster of outer face wall vertically and horizontally to display the surface as stone facing as directed by the Engineer-incharge including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (add for extra labour to all items of plaster), 397 Marking drip coarse in sun shades or facie with 1:3 cement and fine sand mortar as per direction of Engineer-in-charge including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 398 20 mm thick rough cast exterior cement plaster on walls consisting 10 mm thick backing cast of 1:3 cement mortar (1 cement :3 coarse sand) and 10 mm thick finishing coat of 1:3 cement mortar (1cement :3 coarse aggregate of size 6mm to 12 mm ) including arises, chamfers and/or rounded angles not exceeding 80 mm. 399 2.5 cm (1) thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 2 cm. (1) graded approved stone grit, laid in panels finished with 3 mm. (1/8) floating coat of neat cement of cement and marble dust in ratio 5:1 as specified over and including 8 cm (3) thick base concrete consisting of cement, fine sand of 1.25 fineness modulus and brick ballast 4 cm. (1½) gauge in the proportion of 1:4:8 and removing any overlapping mortar at the joints of the penals if any and giving them a uniform finish, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 400 (A) As in item no. 601 above but without base concrete. 401 (B) As in item no. 601 above but base concrete consisting of brick ballast and fine sand & cement in prop. 12:6:1 402 As in item (601) above but floor shall be 4 cm (1½) thick instead of 2.5 (1) thick and without base concrete. 403 Add in item (601) to (603) and (605) when floors are polished including supply of extra cement, chapra batti, Carborandum stone, all other materials, labour, Tools & plants etc. required for proper completion of the work. Marble dust shall be added in the floting coat in ratio of 5:1 (cement and marble dust) if necessary but no extra amount will be paid for it. This includes final finish with french mansion polish or any other approved polish. 404 M-150 Brick on edge floor laid dry joints sand filled including preparation of base to proper slope and its ramming including supply of all materials labour and Tools and Plants etc. required for proper completion of the work. 405 As in item (615) above but bricks laid flat. 406 Granolithic marble flooring 2.5 cm. (1) thick consisting of 2 cm. (3/4) thick layer of 1 part cement, 2 parts of approved coarse sand and 4 parts of 2 cm. (3/4) graded approved stone chips including 5 mm (¼) thick surface coat with ordinary cement, black and white or grey or mixed marble chips passing 3 mm. (1/8) but retained on 1.5 mm. (1/16) mesh screen in proportion of 1:2 as specified or directed by the Engineer-incharge and polished by hand or machine and finally finished with French Mansion Polish or any other approved polish and including 8 cm (3) 1:6:12, concrete base, including supply of all materials, labour, Tools and Plants etc. required for proper completion of the work 407 As in item (620) above but when white cement is used in top 5 mm (¼) layer. 408 As in item no. (620) above but when coloured floors are to be made. 409 Granolithic marble dado 2 cm. (¼) thick consisting of 15 mm. (9/16) thick layer of one part cement, 2 parts of approved coarse sand including 5 mm. (3/16) thick surface coat with ordinary cement black or white or grey or mixed marble chips passing 3 mm. (1/8) but retained on 15 mm. (9/16) mesh screen in proportion of 1:2 as specified or directed by the Engineer-in- charge and polished by hand or by machine and finally finished with French Mansion Polish or any other approved polish including supply of all materials, labour, Tools and Plants etc. required for proper completion of the work. 410 Same as item no. 625 above but 12 mm. thick dado. 411 As in item (625) above but when white cement is used in top 5 mm. (3/16) thick layer instead of ordinary cement. 412 As in item (625) above but when coloured dados are to be made. 413 Supply and fixing 6 mm. (¼) China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete, including supply of all materials, labour and Tools and Plants 414 Providing and fixing glass strips of 4.00 mm (1/8) thickness in joints of floor and skirting at the time of laying labour, tools and plants etc. complete (a) of 2.2 cm. depth 415 Providing and fixing glass strips of 4.00 mm (1/8) thickness in joints of floor and skirting at the time of laying labour, tools and plants etc. complete (b) of 3.5 cm. depth 416 Providing and fixing glass strips of 4.00 mm (1/8) thickness in joints of floor and skirting at the time of laying labour, tools and plants etc. complete (c) of 2.2 cm. depth and of 5 mm thickness 417 Providing and fixing glass strips of 4.00 mm (1/8) thickness in joints of floor and skirting at the time of laying labour, tools and plants etc. complete(d) of 3.5 cm. depth and of 5 mm thickness 418 Extra for making chequers of approved patterns on cement concrete, floor, steps landing etc. 419 Supply and fixing of Kota stone in floor ing 20 mm thick and joint filled with 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 12 mm base coat (bedding) of 1:2 cement & coarse sand morter and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 420 As in item no. New item (1) above but 25 mm thick. 421 Supply and fixing 10 to 12 mm thick Kota stone tiles in skirting or dado laid with 1:2 cement and approved coarse sand morter finished with in its cement colour slurry, jointing and polished of approved quality complete, including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 422 Supply and fixing 6 to 8 mm thick ivory or light shades vitrefied tiles 600x600 mm size in flooring and skirting with 1:3 approved cement and coarse sand morter finished with in its cement colour slurry, jointing and polished of approved quality complete, including supply of all materials, labour, tools andplants etc. required for proper completion of the work. as per direction of Engineer - in- charge 423 Painting or varnishing work in small areas or new wood work with one coat (upto one square metre of ready mixed priming paint and one coat of approved superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used ISI marked. 424 As in item (641) above but for every coat after first coat. 425 As in item (642) above but for every coat on previously painted old wood or Iron work including its sand papering, rubbing and cleaning as required for proper completion of work. 426 Painting roofs or other iron work in large areas with one coat priming and one coat of approved (above one Sq. Metre) paint (British antesol or equivalent) including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used ISI marked 427 As in item (644) above but for every coat after the first coat. 428 As in item (645) above but for every coat over previously painted surface 429 Painting or varnishing with valsper or other approved high grade enamel or super par synthetic clean varnish complete one coat over previously painted surface including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used ISI marked 430 As in item (647) above but for every subsequent coat on previously treated surface . 431 Distempering (first coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shalimar, Asian Paint after thoroughly brushing the surface free from mortar dropping and other foreign matters and also including the surface even with plaster of Paris or approved synthetic materials and sand papered smooth including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 432 As in item (649) above but for every coat after the first coat. 433 As in item (649) above but for every coat after the previous coat or subsequent coat. 434 One coat hot coaltar on new surface including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 435 As in item (652) above but for every coat after the first coat or on previously treated surface. 436 One coat surface or other approved preservative on new wood work, including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 437 As in item (654) above but for every coat or on previously treated surface. 438 Oiling wood work with double boiled linseed oil including supply of all materials labour, Tools & plant etc. required for proper completion of the work. 439 Removing paint or varnishing with paint remover or with caustic Soda, including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 440 Polishing with French Polish or wax polish (in proportion 2 bees wax : 1.5 linseed oil : 1 turpentine oil : 0.5 varnish by weight) on new wood and wood based surface to give an even surface including cleaning the surface of all dirt, dust and sand prepared smooth and a coat of wood filter including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 441 As in item No. (658) above but on previously polished wood or wood based surface. 442 Finishing wall with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 443 Same in item no. (660) but for each coat of water proof cement paint after the first two coat to give an even shade 444 Finishing wall with one coat of water proof cement paint of approved quality on previously old treated surface with this paint to give an even shade including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 445 Same aas item 660 but for weather coat. 446 Sameaasitembut over previouslypainted surface weather coat. 447 Providing cement primer on old/new surfaces 448 Providing wall putty on New surface with approvel quality material of Berger/J.K./Birla or similar make 2 coats 449 Providing wall putty on old surface with approvel quality material of Berger/J.K./Birla or similar make 2 coats 450 White washing one coat including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 451 As in item 671 above but Two coats. 452 As in item 671 above but Three coats. 453 Colour washing one coat using approved. Colouring material buff, blue, gray or brown shade including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 454 As in item 674 above but two coats. 455 As in item (674) but using approved colouring material of pink, green or yellow shade. 456 As in item 676 above but two coats. 457 As in item (674) above but colour washing with copper or iron sulphate one coat. 458 As in item 678 above but Two coat. 459 Cement washing including supply of all materials, labour, Tools & plant etc. required for proper completion of the work. 460 One priming coat and one coat of dry distemper on new work including supply of all materials, labour, Tools & plant etc. reqired for proper completion of work. 461 As in item (681) but for each coat of distemper after the first coat 462 Dismantling sundries brick work including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 463 Dimantling brick work or stone work in lime or cement mortar and including stacking of materials as directed be the Engineer-in-charge within a distance of 60 meter (200 feet). 464 As in item (692) above but in mud mortar. 465 Dismantling reinforced cement concrete or reinforced brick work including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 466 Dismantling Jack arched or wooden beam and barga roofs including beam, roof concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 467 As in item (695) above but only roof concrete. 468 Dismantlingcementconcreteorbrickor granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 469 As in item (697) above but floor to be stone flagged or tiled floor. 470 Dismantling corrugated Iron roofs walls or partitions,includingpurlins,battensand vertical supports and including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 471 Dismantling of girders, trusses and other steel work including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 472 Dismantling doors or windows including chaukhats with hold fast and including stacking of materials as directed by the Engineer-in- charge within a distance of 60 metre (200 feet). 473 Dismantling doors or windows leaves including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 474 Dismantling doors or windows including chaukhats but excluding hold fast and including stacking of materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 475 Dismantling existing plaster including disposal of refuse as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). 476 Raking out joint of brick work in cement or lime morter to a depth 1 cm. (3/8) including disposal of refuse as directed by the Engineer-in- charge within a distance of 60 metre (200 feet). 477 Scraping old white or colour wash including disposal of refuse as directed by the Engineer-in- charge within a distance of 60 metre (200 feet). 478 Supply and fixing of 10cm. (4) internal dia A.C. down pipes Everest or charminar make complete with bends with door at top and plain at bottom and grantings and including supply of necessary M.S. clamp 2.5cm x 3mm. (1 x1/8) fixed to walls with cement motar (1:2) and including supply of 15 cm (6) long 6mm. (1/4) dia nail all materials, labour and T& P. etc. required for proper completion of the work and also including repair of plaster pointing etc. if damaged during fixing of the pipes. 479 As per item No. 730 above but for 10.0 cm. PVC down pipe.(kissan/suprime make) 480 As per item No. 730 above but for 7.5 cm. PVC down pipe. .(kissan/suprime make) 481 As per item No. 730 above but for 5.00 cm. PVC down pipe..(kissan/suprime make) 482 Providing and injecting chemical for preconstruction anttermite treatment and creating and chemical barrier under and around the column pits wall trenches basement excavation top surface in plinth filling junction of wall and floor, along the external per meter of binding expansion joints surrounding or pipes and conduit etc. complete (plinth area of the building at ground floor only shall be measured as per I.S. 6313 (part II 1981) Aldrine emulsifiable concentrate or any other approved material such as heptachlor of chlordane will be used. The rate of application of chemical emulsion shall be as follows :- 1.Treatment for massonary and foundation 5 liters per sqm. 2.Back fill in immediate contact with foundation 7.5 liters per sqm. 3.Treatment of surface of plinth filling 5 liters per sqm. 4.Treatment of soil along external perameter of Building 7.5 liters per sqm 5. Treatment of soil under external parameter 5 liters per sqm. 483 Providing & injecting chemical for post Constructional anti termite treatment with drilling holes at junction of floor with walls & pillars, the application of chemicals shall be as per relevant I.S. code and the rate of application of chemical shall also be as provided in the I.S. code, including quarterly inspection and providing required treatment for one year. As direction by the Engineer-in-charge. 484 Consolidation of Kankar by hand rammer including opening out stacks sorting kankar into three sizes, repairing patches in existing road suface with kanker making medhi to retain water and ramming and also including carriage of metal upto 30 meters (100 ft.) carriage of water 200 metre supply and maintenance of barriers and all tools and plants required for proper completion of work, kankar to be supplied to the contractor free at site. 485 (A) As in item No. 752 above but 12 cm. (loose) thick coat of stone ballast. 486 (B) As in item No. 755 (a) above but excluding roller charges. 487 (D) As in item No. 755 (a) above but upto 10 cm. (loose) thick coat. 488 (E) As item No. 755 (b) above but upto 10cm. (loose) thick coat. but excluding roller charges. 489 Water allowance to be allowed on item No. 751 to 756 including carriage & cost of water where water is not available at site. 490 Dag belling 15cm (6) deep in one line aligned with flags and jhandies as directed by Engineer- in-charge. 491 Painting white/coloured traffic lines 8-15 cm. wide in three coats with approved road making paint (spirit base) as directed by the Engineer- incharge, including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 492 Painting on divider 1 priming and two coats of enamel paint including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. 493 As per item above but every coat after Ist coat and on old surface 494 Brick soling with strainght over burnt bricks laid flat and dry with brick edging on both sides including preparation of subgrade to prescribed camber and including supply of bricks, filling joints with local earth of P.I. 5 to 7, spreading blinding coat 1 cm (3/8) depth of local earth over the entire surface and including supply of all materials, labour Tools & Plants etc. required for proper completion of the work. 495 As in item No. 762(a) above but with bricks laid on edge. 496 M-150 Brick on edge pavement on parties with bricks, laid dry joints filled with local sand including preparation of base to proper slope, and its ramming, spreading layer of 1 cm. (3/8) depth of local sand over the subgrade and including supply of all materials, labour Tools &plants etc. required for proper completion of the work. 497 Renewing patries 1.5 metere wide including dressing surface filling upto 8cm (3) depth and making namunas, at every 15 metre apart on either side of the road true to patri template with side slopes of 1:2 etc. trenches for taking the earth to be so dug that they form a continuous side drain at road boundary. 498 Brick lining on both side of the road of M-150 bricks 7 cm. wide. 11 cm. deep, laid with mud mortar including labour & supply of bricks finished to the required template and in proper alignment and also including dressing and ramming the excavated earth as directed by the Engineer-in-charge. 499 Cleaning the existing painted /primed surface and laying premix 2cm. (3/4) thick over a tack coat with graded approved grit and bitumin (labour only) including heating the paint and grit to the required temperature and mixing either in mixer/ hand drum or by manual including cartage of materials, maintenance of side parties and watering them during operation for proper completion of the work as directed by the Engineer-in-charge . including labour charges for tack coat. 500 As in item No. 781 above excluding T&P and sundries etc. for departmental works. 501 As in item No. 781 above but in Patches. 502 As in item No. 781(a) but in Patches. 503 Cleaning the premix surface and laying seal coat with approved 6mm (1/4) graded grit and bitumin (labour only) including heating the paint to the required temperature and mixing either in mixer, hand drum including cartage of materials, maintenance of side parties and watering them during operation for proper completion of the work as directed by the Engineer-in-charge including all T&P and sundries to be arranged by the contractor but exculding roller charges and fuel wood. 504 As in item No. 783 above but in Patches. 505 Providing and applying primer coat over prepared surface of granular base with slow setting bitumen emulsion with spray set including cleaning of W.B.M. surface spreaying primer @ 0.6 kg/sqm (excluding emulsion) all labour T & P etc. as per MORT&H Specification. (labour rate only) in patches 506 Brick soling with straight over brunt bricks laid flat and dry (labour only) including preparation of subgrade to prescribed camber, filling joints with local earth spreading a blinding coat 1 cm (3/8) depth of local earth over the entire surface and including labour T&P etc.required for proper completion of the work.. 507 As in item No. 785 above but with bricks laid on edge. 508 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE(i) 350 mm dia 509 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE (ii) 600 mm dia 510 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE(iii) 800 mm dia 511 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE(iv) 900 mm dia 512 Laying of Hume pipe in position (labour only) including labour and T&P etc. required for proper completion of the work NP-3 TYPE(v) 1000 mm dia 513 Fixing of joints in hume pipe with juit and cement etc.including cost of all matrial labour and T&P etc. required for proper completion of the work, (i) 350 to 600 mm dia 514 Fixing of joints in hume pipe with juit and cement etc.including cost of all matrial labour and T&P etc. required for proper completion of the work(ii) 800 to 1000 mm dia 515 (a) Laying and Consolidation of stone ballast in soling. by hand rammer for Patches.(Labour rate only) including filling of pot holes including cartage of water within 200M distance and blinding etc. Complete. 516 (b) Laying and Consolidation of Brick ballast/ bats in soling. by hand rammer for Patches.(Labour rate only) including filling of pot holes including cartage of water within 200M distance and blinding etc. Complete. 517 Barricating with approved wooden ballies vertical 10cm. Dia and 2m long fixed in ground 45 cm Deep and 2m apart including 2 rows of horizontal ballies not less than 8cm Dia 45 cm apart centre to centre tied by narial rope including cartage of all material and also including hire charges of ballies complete as direction of Engineer In charge. For two days 518 As item above but for more than 02 days. 519 As per item above but with three rows of horizontal ballies. 520 Dismantling of old brick laid on edge kharanja including stacking of old bricks . 521 As per item above but bricks laid flat / C.C. Interlocking tiles 522 Providing & laying of hot applied thermoplastic compound 2.5 m.m. thick including reflectorising glass beads @ 250 gms./Sq.mt. area. Thickness of 2.5 mm. inclusive of surface applied glass beads as per I.R.C. 2.35. The finished surface must be level, uniform and free from steaks and holes.Supplying & laying of Empty cement bags 523 Supply of 60mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 35 MPa and 4.00 kg per nos including cost of all material labour T & P .(i. ) Grey (ii ) Color 524 Supply of 60mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 35 MPa and 4.00 kg per nos including cost of all material labour T & P .(i. ) Grey (ii ) Color 525 Supply of 80mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 40 MPa and weight 4.50 kg per No. confirming to IS: 15658- 2006 including cost of material, labour, T & P (i. ) Grey (ii ) Color 526 Supply of 80mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 40 MPa and weight 4.50 kg per No. confirming to IS: 15658- 2006 including cost of material, labour, T & P (i. ) Grey (ii ) Color 527 Supply of 100mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 50 MPa and weight 5kg per No. confirming to IS: 15658- 2006 including cost of material, labour, T & P .(i. ) Grey (ii ) Color 528 Supply of 100mm thick ISI marked confirming to IS: 15658-2006 I shaped mechanically compressed interloking cement concerete paver blocks, smooth high gloss finish, skid resistant; manufactured from rubber moulds through vibro- compression mechanism. high pressure and control vibration machine having plan dimension 200 x (160+120mm) with minimum 5mm thick topping of O.P. cement mixed with 25% marble powder. The Compressive strength of concerete paver block shall not be less than 50 MPa and weight 5kg per No. confirming to IS: 15658- 2006 including cost of material, labour, T & P .(i. ) Grey (ii ) Color 529 Providing and laying of interlocking concrete Block pavement having thickness 60 mm as per drawings and technical specification Clause 1504. (Exclusive G.S.B.) 530 Providing and laying of interlocking concrete Block pavement having thickness 80 mm as per drawings and technical specification Clause 1504. (Exclusive G.S.B.) 531 Providing and laying of interlocking concrete Block pavement having thickness 100 mm as per drawings and technical specification Clause 1504. (Exclusive G.S.B.) 532 Providing & supply gunny bags including cost of sand and stitching of bags and laying in position. 533 Laying of interlocking tiles (labour only) 534 Disposal or malba 535 primaxing carpet 20 mm 536 seal coat 537 earth work in filling 538 45-90 mm gauge stone ballast 539 53-22.4 mm gauge stone ballast 540 stone screening meterial 541 mild steel for rcc work 542 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. a) 15 mm dia. nominal outer dia Pipes 543 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Chargeb) 20 mm dia. nominal outer dia Pipes 544 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Chargec) 25 mm dia. nominal outer dia Pipes 545 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charged) 32 mm dia. nominal outer dia Pipes 546 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Chargee) 40 mm dia. nominal outer dia Pipes 547 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. a) 15 mm dia. nominal outer dia Pipes 548 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. b) 20 mm dia. nominal outer dia Pipes 549 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. c) 25 mm dia. nominal outer dia Pipes 550 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. d) 32 mm dia. nominal outer dia Pipes 551 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineerin- Charge. External work.. a) 15 mm dia. nominal outer dia Pipes 552 b) 20 mm dia. nominal outer dia Pipes 553 c) 25 mm dia. nominal outer dia Pipes 554 d) 32 mm dia. nominal outer dia Pipes 555 e) 40 mm dia. nominal outer dia Pipes 556 f) 50 mm dia. nominal outer dia Pipes 557 g) 62.50 mm dia. nominal outer dia Pipes 558 h) 75 mm dia. nominal outer dia Pipes 559 i) 100 mm dia. nominal outer dia Pipes 560 j) 150 mm dia. nominal outer dia Pipes 561 Providing and fixing brass stop cock ISI marked approved quality as per direction of Engineer-in- charge. a) 15 mm nominal bore 562 b) 20 mm nominal bore 563 Providing and fixing brass stop bib cock ISI marked approved quality as per direction of Engineer-in-charge. a) 15 mm nominal bore 564 b) 20 mm nominal bore 565 Providing and fixing ball valve (brass)ISI marked approved quality complete , High & low pressure with plastic floats complite as per direction of Engineer-in-charge.High or low pressure with plastic floats: a) 15 mm nominal bore 566 b) 20 mm nominal bore 567 c) 25 mm nominal bore 568 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 a) 15 mm nominal bore 569 Providing and fixing C.P. brass long nose bib cock of approved quality confirming to ISI standards and weighing not less than 810 gms. a) 15mm nominal bore. 570 Providing and fixing C.P. brass stop cock (concealed) of approved quality confirming to ISI standards IS 8931 a) 15mm nominal bore. 571 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality confirming to IS:8931 a) 15 mm nominal bore 572 Providing and placing on terrace (at all floor levels) polyethylene water storage tank lSI: 12701 marked(Sintex or equivalent) with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete as per direction of Engineer-in- charge. 573 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White glazed earthen ware(Indian Type)/Neycer W.C. Pan 580 mm Dia. 574 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 30x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern 575 Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern 576 Single half stall urinal with 5 litre PVC. automatic flushing cistern 577 Range of two half stall urinals with 5 litre PVC. automatic flushing cistern 578 Range of three half stall urinals with 10 litre PVC. automatic flushing cistern 579 Range of four half stall urinals with 10 litre PVC. automatic flushing cistern 580 Single squatting plate with 5 litre P.V.C. automatic flushing cistern 581 Range of two squatting plates with 5 litre P.V.C. automatic flushing cistern 582 Range of three squatting plates with 10 litre P.V.C. automatic flushing cistern 583 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C. P. brass pillar taps 584 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 585 White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 586 White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap 587 White Vitreous China Angle back wash basin of size 600x480 mm with single 15 mm C.P. brass pillar tap 588 White Vitreous China Angle back wash basin of size 400x400 mm with single 15 mm C.P. brass pillar tap 589 White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 590 Providing and Fixing while vitreous china pedestal for wash basin completely at the back for the reception of pipes and fittings. 591 ProvidingandfixingStainlessSteelAISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm bowl depth 250 mm 592 510x1040 mm bowl depth 250 mm 593 510x1040 mm bowl depth 225 mm 594 510x1040 mm bowl depth 200 mm 595 470x420 mm bowl depth 178 mm 596 Long pattern W.C. pan size of 580 mm 597 Orissa pattern W.C. pan size 580x440 mm 598 Providing and fixing water vitreous china pedestal type (Eurepean type/wash down type) 599 Providing and fixing 8 mm dia C.P./ S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer–in- charge 600 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS 7231, with all fittings and fixtures complete.10 litre capacity – white 601 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 10 litre (full flush) capacity-white 602 Providing and fixing P.V.C. waste pipe for sink or wash basin including PVCwaste fittings complete. Semi rigid pipe 32 mm dia / 40 mm dia 603 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 604 Providing and fixing soil, waiste and vent pipes: 100 mm dia Sand cast iron S&S as per IS - 3989 605 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 606 Hubless centrifugally cast (wpun) iron pipes epoxy coated inside & outside IS 15905 75 mm dia meter 607 Sand cast iron S&S as per IS - 1729 608 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 609 Hubless centrifugally cast (wpun) iron pipes epoxy coated inside & outside IS 15905 610 Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand): 100 mm dia 611 75 mm dia 612 50 mm dia 613 White vitreous china dual purpose W.C. pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend ISI Mark Kajaria eqvilent Indian made Brand. 614 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting of flushing capacity 3 litre/6 litre (adjustable to 4 litre/ 8 litre), including seat cover and cistern fittings, nuts, bolts and gasket etc complete. ISI Mark Kajaria eqvilent Indian made Brand. 615 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50kg and frame to be not less than 2.70 kg as per standard design. 100x100 mm size P type 616 with common burnt clay (non modular) bricks of class-150 150x100 mm size p type 617 with common burnt clay (non modular) bricks of class-150 618 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 619 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg 620 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Square shape 450 mm internal dimensions 621 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 450 mm internal diameter 622 Square shape 450 mm internal dimension 623 Circular shape 500 mm internal diameter 624 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg 625 Providing and fixing toilet paper holder standrad size ISI marked C.P. brass as per direction Engineer-in-charge 626 Painting letters upto 2.5 cm. size including supply of all materials, labour & tools and plants etc. required for proper completion of the work. 627 As in item 817 above but size above 2.5 cm. but upto 8 cm. 628 As in item no. 817 above 8 cm. but upto 15 cm. 629 Repairing letters upto 2.50 cm. size including supply of all meterials labour and tool and plants etc. required for proper comletion of the work 630 As in item NO. 820 above but size above 2.5 cm. but upto 8 cm. 631 As in item NO. 820 above but size above 8 cm. but upto 15 cm. 632 Painting Border line upto 2.5 cm. wide 633 Painting Border line upto 2.5 cm. to 5 cm. wide 634 Re-Painting Border line upto 2.5 cm. wide 635 Re-Painting Border line upto 2.5 cm. to 5 cm. wide 636 Repainting and relettering number plates on ends of parapets of culverts and bridges and boader line in letters height from 2.5 cm. to 8 cm. with approved enamael paint of superior quality including supply of all materials, labour and T & P etx. required for proper completion of the work. 637 Repainting and relettering of K.M. stones as per IRC design (except 5th km. Stone) with approved enemal paint of superior quality including supply of all materials, labour and T & P etc. required for proper completion of the work. 638 As in item 832 above but 5th km. stone 639 As in item 832 above but 200 H.M. stone 640 Varnishing /Painting on chair /side rack with stand and such other items including all matrial labour T&P etc. complite for proper completion of the work. 641 Varnishing /Painting on Double bed including all matrial labour T&P etc. complite for proper completion of the work. 642 Varnishing /Painting on Singal bed/ Sofa/ Dining table including all matrial labour T&P etc. complite for proper completion of the work. 643 Cutting and repairing of walls or windows for fitting of window type A.C. inculding wooden bidding after fixing. 644 White washing and hirmichi washing of culverts and trees upto a distance of 5 M. from the edge of black top in three bends of 1 width at a height of 1 M. from the crown of the road on either side of road. including supply of all materials, labour, T & P etc. required for proper completion of the work. 645 (a) Same as above but with departmental labour 646 Retro-Reflectorised Traffic Signs Direction and place identification signs up to 0.90 sqm Size BoardProviding and erecting direction and place identification retro- reflectiorised sign as per IRC-67 made of high intensity grade sheeting the retro- reflecive sheeting type -IV shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67- 2012 & proof of the same in form of Government report shall be uploaded while quoting tender vide MOR&TH clause 801.3 fixed over aluminium sheeting 2mm thick with area exceeding 0.9 sqm supported on a miled steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing complete. as per direction E- In- Charge Note : The Composite warranty jointly signed by original manufacturer & authorized converter of at least 7 years shall be furnished on non judicial stamp of required denomination both for retro reflective sheet and also complete signage. 647 Direction and place identification signsMore then 0.90 sqm Size Board Providing and erecting direction and place identification retro- reflectiorised sign as per IRC-67 made of high intensity grade sheeting the retro- reflecive sheeting type -IV shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67- 2012 & proof of the same in form of Government report shall be uploaded while quoting tender vide MOR&TH clause 801.3 fixed over aluminium sheeting 2mm thick with area exceeding 0.9 sqm supported on a miled steel single angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with M-15 grade cement concrete 45x45x60 cm below ground level as per approved drawing complete. as per direction E- In- Charge Note : The Composite warranty jointly signed by original manufacturer & authorized converter of at least 7 years shall be furnished on non judicial stamp of required denomination both for retro reflective sheet and also complete signage. 648 Retro Reflective Signs (Type-IV Sheet) for single side Providing and fixing retro-reflective signboards comprising of customised modular PU Epoxy Coated MS angle iron frame work, aluminum composite panel (ACP) as base board. micro prismatic retro-reflective sheet and electro cut colored overlay film/latex printing. The horizontal and vertical members including inclined outer members of the MS frame module shall be made of pair MS angle iron. No panel size shall be more than one sqm and each panel shall be braced diagonally (one way only) with MS angle. The MS frame module shall have length not more than 3 mtr. The aluminum composite panel (ACP) shall have a thickness of 4mm with 0.5 mm thick skin of aluminum on both sides. The ACP shall be fixed on the MS frame with pop riveting or with self taping SS screws 5mm dia spaced not more than 300mm centre to centre ensuring that no riveting is seen on either face of the frame. On the front visible face of the ACP, micro prismatic retro-reflective sheet conforming to Type-IV of ASTM. D 4956-09 shall be pressure fixed. The retro-reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67 2012 & proof of the same in form of government report shall be uploaded with quoting tender. The rate include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-Charge. Signage on MS angle frame of (35x35x5)mm 649 Retro Reflective Signs (Type-IV Sheet) for both side Providing and fixing retro-reflective signboards comprising of customised modular PU Epoxy Coated MS angle iron frame work, aluminum composite panel (ACP) as base board. micro prismatic retro-reflective sheet and electro cut colored overlay film/latex printing. The horizontal and vertical members including inclined outer members of the MS frame module shall be made of pair MS angle iron. No panel size shall be more than one sqm and each panel shall be braced diagonally (one way only) with MS angle. The MS frame module shall have length not more than 3 mtr. The aluminum composite panel (ACP) shall have a thickness of 4mm with 0.5 mm thick skin of aluminum on both sides. The ACP shall be fixed on the MS frame with pop riveting or with self taping SS screws 5mm dia spaced not more than 300mm centre to centre ensuring that no riveting is seen on either face of the frame. On the front visible face of the ACP, micro prismatic retro-reflective sheet conforming to Type-IV of ASTM: D 4956-09 shall be pressure fixed. The retro-reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67: 2012 & proof of the same in form of government report shall be uploaded with quoting tender. The rate include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-Charge. Signage on MS angle frame of (35x35x5)mm 650 Retro Reflective Signs (Type-IV Sheet) for both side ACP shall be fixed on the MS frame with pop riveting or with self taping SS screws 5mm dia spaced not more than 300mm centre to centre ensuring that no riveting is seen on either face of the frame. On the front visible face of the ACP, micro prismatic retro-reflective sheet conforming to Type-IV of ASTM: D 4956-09 shall be pressure fixed. The retro-reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67: 2012 & proof of the same in form of government report shall be uploaded with quoting tender. The rate include all materials, labour, equipments, fabrication, transportation, erection, installation and incidentals all complete as per direction of the Engineer-in-Charge. Signage on MS angle frame of (35x35x5)mm 651 Retro-reflectorised Traffic sign as per IRC 67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC 67:2012 made of high intensity grade sheeting vide clause 801.3, fried over aluminum sheeting type-IV 1.5 mm thick supported on a mild steel angle iron post 75mm x 75 mm x6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm below ground level as per approved drawing. The retro-reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67: 2012 & proof of the same in form of government report shall be uploaded with quoting tender. a) 90 cm equilateral triangle with diffinitation plate size (20 cm x 60 cm) 652 b) 60cm equilateral triangle with diffinitation plate size (20cm x 60cm) 653 c) 60 cm Circular with diffinitation plate (20 cm x 60 cm) 654 d) 80mm x 60mm rectangular with diffinitation plate (20cm x 50cm) 655 e) 60mm x 60mm rectangular with diffinitation plate (20cm x 50cm) 656 f) 60 cm x 60 cm square with diffinitation plate ( 20 cm x 60 cm) 657 g) 90 cm high octagon 658 h) 50 x 60 cm single chevron 659 i) 155 x 60 cm Double chevron 660 j) 30 x 90 cm (Left/Right) Object Hazard 661 k) 45 x 90 cm two way Object Hazard 662 l) 30 x 90 cm +45 x 78 cm Guarded/unguarded Railway crossing 663 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 .The finished surface to be level, uniform and free from streaks and holes. Rates are inclusive of all taxes, royalty, etc. all T&P/machine material and labour required for proper completion of work. 664 Supply, fixing and hoisting of 6.00-7.00 m. spanCantilever Structure in position with one vertical post of 6.00 M. clear height from the top of R.C.C. foundation made of 300 mm. dia pipe welded with 10 mm thick MS plate at bottom supported with 10 mm thick MS plate stiffners & two nos. 8 mm thick MS plates at top welded with structure of 40 mm NB (M) pipe comprising of horizontal, vertical & bracing pipe of 32 mm NB (M) as per structural design requirements & approved drawing with vertical & lateral clearance given in clause 802.2 & 802.3 including one coat of primer and two coats of synthetic enamel paint on the whole structure & installed as per clause 802.7 over a designed support system made up of concrete including excavation, lean concrete 1:4:8 cement, coarse sand and approved 20 mm grit and R.C.C. 1:2:4 with cement, coarse sand and approved 20 mm grit complete for fixing the complete structure in position as per direction of E/I charge. With 7 years warranty. Rates include design, fabrication, supply, transportation and erection of the signage structure inclusive of all taxes, royalty, etc. all T&P/machine material and labour required for proper completion of the work. 665 Supply, fixing and hoisting of 12.00 - 15.00 M span Overhead Structure in position with two vertical posts of 6.00 M. clear height from the top of R.C.C. foundation made of 300 mm. dia pipe welded with 10 mm thick MS plate at bottom supported with 10 mm thick MS plate stiffeners & two nos.10 mm thick MS plates at top welded with structure of 50 mm NB (M) pipe comprising of horizontal, vertical pipe of 40 mm NB (M) and bracing pipe of 32 mm NB (M) as per structural design requirements and approved drawing with vertical and lateral clearance given in clause 802.2 and design, fabrication, supply, transportation and erection of the sign board and also inclusive of all taxes, oyalty, etc all T&P/machine material and labour required for proper completion of the work. 666 Reflective Raised Pavement Marker Providing and fixing of raised 667 Reflective Raised Pavement Marker with shanks Providing and 668 Supplying & fixing of Linear Delineator System (LDS)panels made of Micro prismatic Retro Reflective sheeting Type XI duly laminated on thin aluminium foil to a unique corrugated shape to provide retro reflection across wide range of observations and external angles. Each LDS panel should be of nominal length of 33 inch and each ridge shall be approximately 0.34 inch high. Each LDS panel is to be firmly fixed on existing Concrite / brick work with 16 Nos Fastner/ screw as per IRC 79-2019 -Rates are inclusive of all taxes, royalty,etc. all T&P/machine material and labour required for proper completion of work. 669 Providing & fixing of Bollard made (Single side) out of aluminium sheet 4mm thick welded poly shaped to make it monolithic pillar size 1200mm high Bollard is having a frame 900x600mm and 600mm dia for fixation made out of 35x35x5mm angle iron and from side is fully coverd fixing the complete structure in position as per direction of E/I. charge. With 7 years warranty. Rates include design, fabrication, supply, transportation and erection of the sign board and also inclusive of all taxes, oyalty,etc all T&P/machine material and labour required for proper completion of work. 670 Supply & fixing of Bollard (Double side) Made out of aluminium sheet 4mm thick welded poly shaped to make it monolithic pillar size 1200mm high Bollard is having a frame 900x600mm and 600mm dia for fixation made out of 35x35x5mm angle iron and from side is fully coverd. fixing the complete structure in position as per direction of E/I. charge. With 7 years warranty. Rates include design, fabrication, supply, transportation and erection of the sign board and also inclusive of all taxes, oyalty, etc all T&P/machine material and labour required for proper completion of work. 671 Metal Beam Crash Barrier 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810 672 Metal Beam Crash Barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2.0 m high, 1.5 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete 673 TREE PLATE S/F Reflective tree plate having Size 15 Cm x15Cm, Consisting type XI sheeting over 1.5mm thick aluminium sheet including labour. Material T&P etc for proper completion of the work. 674 Cartage of Ballast, Kankar, Coal, Grit or Sand etc. including loading and unloading but excluding stackings on pucca roads. I st Km. 675 2 nd Km. 676 3 th Km. 677 4 th Km. 678 5 th Km. 679 6 th Km. 680 7 th Km. 681 8 th Km. 682 9 th Km. 683 10 th Km. 684 11 th Km. 685 12 th Km. 686 13 th Km. 687 14 th Km. 688 15 th Km. 689 16 th Km. 690 17 th Km. 691 18 th Km. 692 19 th Km. 693 20 th Km. 694 21 th Km. 695 22 th Km. 696 23 th Km. 697 24 th Km. 698 25 th Km. 699 26 th Km. 700 27 th Km. 701 28 th Km. 702 29 th Km. 703 30 th Km. 704 31st to 75 Km. 705 76st to 100 Km. 706 100st to 200 Km. 707 As in item (231) above but for cement, steel or other materials : Ist Km. 708 2nd and 3rd Km. 709 4th and 5th Km. 710 6th to 10th Km. 711 11th to 20th Km. 712 21st to 30th Km. 713 31st to 50th Km. 714 51 to 75 Km. 715 76th to 100 Km. 716 101st to 200 Km. 717 201st to 250 Km. 718 As in item (231) above but for tar, bitumen Asphalt, Mobile oil or other such materials 1st Km. 719 2nd and 3rd Km. 720 4th and 5th Km. 721 6th to 10th Km. 722 11th to 20th Km. 723 21st to 30th Km. 724 31st to 50th Km. 725 51st to 75 Km. 726 76th to 100 Km. 727 101st to 200 Km. 728 201st to 250 Km. 729 Cartage of brick/stone ballast, kankar coal shingle or sand etc. by head load upto 90 metres (3 chains) including loading and unloading but excluding stacking 730 Loading and unloading of materials like ballast, shingle, kankar, coal or grit etc. excluding their stacking. (a) Loading 731 Loading and unloading of materials like ballast, shingle, kankar, coal or grit etc. excluding their stacking. (b) Unloading 732 Unloading of cement, tar or bitumen drum lighter steel sections and other such materials from wagons and stacking the same on platform. 733 As in item No. 236 (a) above but for heavy articles like joist etc. machinery and unwieldly structures 734 Stacking of bricks on edge in row of two to a height of ten brick and in a length of 100 bricks after dressing levelling of the site as required where bricks are to be stacked. 735 Stacking of coal, surkhi, sand, lime, stone grit, stone/brick ballast & boulders etc. to the required sizes to stacks after necessary dressing of site where such materials are to be stacked. 736 237 (a) above but when the materials are either cement / steel. 737 Loading of cement, tar or bitumen drums, lighter sections of steel and other such materials into wagons. 738 As in item 238 (a) above but for heavy articles like joist, machinery and unwieldly structures. 739 Cartage of R.C.C. Hume pipe 30cm. to 46cm. dia and 1.8 meter to 2.5 metre in length (including collars for which nothing extra will be paid ) including loading and unloading. 1st Km. 740 2nd and 3rd k.m. 741 4th and 5th k.m. 742 6th to 10th k.m. 743 11th to 20 th k.m. 744 21st to 30 th k.m. 745 31st to 50 th k.m. 746 51st to onward k.m. 747 As in item No. 239 (c) above but for R.C.C. Hume pipe 50 to 95 cm. dia and 1.8 meter to 2.5 meter in length carriage to be done by truck or by thela. 1st Km. 748 2nd and 3rd k.m. 749 4th and 5th k.m. 750 6th to 10th k.m. 751 11th to 20 th k.m. 752 21st to 30 th k.m. 753 31st to 50 th k.m. 754 51st to onward k.m.
Contract Date: Jun 15, 2026 Contract Value : Ref. Document
Local Bodies No of Bidders 10
Uttar Pradesh View Result →
9.
Housing Urban and Rular Development #11286216 AOC
Tender For Construction Of New Primary Health Center (Phc New Bldg) At Perumalmalai H/O Adukkam, Kodaikanal Block.; 2 Clearing lightjungle vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 3 Earthwork excavation for foundation (for narrow excavation) to full depth as per designed in all soils and sub soils except soft disintegrated rock not requiring blasting and hard rock requiring blasting and bailing water wherever necessary. 4 Supplying and filling in foundations and basement with fillingM sand in layers not exceeding 15 cm. thick, well watered ,rammed and consolidated etc. complete complying with standard specifications. 5 Plain Cement Concrete 1 : 4 :8 ( one part of cement, four parts of sand and eight parts of hard broken stone ) using 40 mm gauge hand broken hard broken granite stone jelly complying with standard specifications in foundations and basement. 6 Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers is not exceeding 200 mm thick, with available earth at site. 7 Supplying and filling of good earth filling locally available earth transported from the outside including consolidation,leveling specifiedin layers of not exceeding 200 mm thick., etc. complete. 8 Supplying and erecting Centering and Shuttering for soffits including necessary supports and strutting up to 3 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification.(Payment for centering shall be given after the concrete is laid). 9 Upto Basement 10 Ground Floor 11 First Floor 12 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement ratio with plasticizer using 20mm and down concrete structural elements under controlled water graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the depart- mental officers comple.-1m3 13 Foundation & Basement 14 Ground Floor 15 First Floor 16 Steel - Fe 500D : Supply, fabrication and placing of reinforcement steel of high yield strength ribbed bars of various diameters and grade conforming to IS 1786 for reinforced concrete work. The work includes recoiling, straightening, cutting, bending, fabricating, and placing in position, at all levels including lead and lift, according to drawings, specifications etc. complete and supply & use of 18G black annealed binding wire double fold to tie the bars in position and providing precast cement/ PVC cover blocks for main reinforcement to ensure specified cover and complete., including all labor charges etc as directed by departmental officers. 17 Brick work in following Cement Mortar 1:5 using best quality Country bricks of size 83/4 x 41/4 X2 3/4 for foundation and basement including curing etc., complete complying with standard specification. Including scaffolding curing cost of reinforcement etc. all complete as per specifications and drawings as directed by the Engineer in-charge. 18 Foundation basement 19 Ground floor 20 First floor 21 Brick partition walls of 11.50cm thickness using best quality Country bricks of size 83/4 x 41/4 X2 3/4in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 22 Ground Floor 23 First Floor 24 PLASTERING WORK 25 Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing.The Surface shall then be allowed to dry for atleast 48 hours.It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface.Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete].The Putty shoule be got approved by the Executive Engineer before use on work. 26 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and ThreeM.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers 27 Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or chambering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labor complete in all respects including all lead, lift and descent andas directed. 28 FLOORING AND DADOOING 29 Paving the floor with best quality Vitrified Tiles of size 600 x 600 x 8mm of approved color, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same color pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).Basic Cost-Rs.776/sq.m 30 Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works).Basic cost-Rs.464/sq.m 31 Dadooing the walls with colouredDadooing Ceramic tiles of size 150mm x 150mm x 6mm approved size , quality and colour set in CM 1 : 2 - 10 mm thk. And pointed with suitable cement including finishing the joint and pointing flesh with walls and tile surfacein all floors at the rate of 0.40 Kg /Sqm etc. complete. 32 Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 33 Providing, fabricating and fixing M.S. grillsWindows,and ventilator, gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by the Engineer. 34 S.S Handrail 35 Manufacturing,supplying and fixing of stainless steel handrails for staircase using 50mm dia 304L grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between.The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance,electrical charges,ect.complete. 36 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete 37 Supply and Fabrication of UPVC doorincluding cost and conveyance of all charges etc complete. 38 Solid PVC door shutters Toilet door using 19 Gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings.The over all size of styles shall be 50mm x 30mm.The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter. 39 UPVC Windowsupplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride) windows of casement type (open) from the profile the size of outer frame 60mmx58mm and shutter profile are reinforcement with g/1mm 125GSMand 100% corrosion free, the profiles are multi chambered sectionwith wall thick of 2mm. The EPDM rubber (black color) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power points locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed or plainglass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and shouldhave key lockable action, security protective hinges, strong lockingsystems and as per sizefor arrestingnoise and energy loss. 40 UPVC VENTILATOR: Supplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride)Louvered Ventilators of from the profile the size of outer frame 60x58mm and shutter profile the size of 60x78mm both profile size of 60x78mm both profiles are reinforced with GI/1MM 125GSMand 100% corrosion free , the profile are multi chambered sections withwall thick of 2mm. The EPDM rubber (black color) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiation pin headed glass 4mm thick should be fixed to the wall with 100% packing with screws and silicon packing all around the frame. The ventilator should be got approved from the Executive Engineer before use on work. 41 PAINTING WORK 42 Painting two coats of synthetic Enamel paint of approved colour and make over one coat of anti corrosive Zinchromite primerover new wood / steel work, suitably prepared for receiving the paint by surface scraping, rubbing applying filler etc. including cost of filler, primer, paint all complete as per drawings and specifications. 43 Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the wallssmooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.(The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). 44 Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 45 Weathering Course Concrete using best quality broken brick jelly of 20 mm uniform gauge in pure slaked lime ( NO Sand to be used ( over the RCC roof slab in the proportion of brick jelly to lime being 32 : 121/2 by volume laid over in single layer and consolidated to the required slope and finished thickness and beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime, jiggery water etc. complete complying with standard specifications and as directed 46 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 47 Plumbing Work 48 Supplying and fixing of Indus floor mounted white colour European water closet Parryware or equivalent, with seat cover and dual flush (3 & 6 lit) cistern having P trap withseat cover, supplyingnon corrosive hinges, CP bolts, nuts, washers, providing and fixing dash anchor fastners with bolts / L -brackets with anticorrosive paint cutting grooves in masonry or concrete surfaces, groutingwith cement concrete 1:2:4 mix, using 20mm size stone jelly,restoring the damaged portion to their original condition using required materials,fixing the water closet to perfect level,alignment,testingetc.complete. 49 Providing and keeping in stores, shifting to the place of installation, fixing,testing and commissioning ofwhite coloured vitreous china under counterRegular rectangular wash basin with brackets/ G.I. rag bolts and nuts painted,32mm dia brass C.P. waste coupling, (heavy) 32mm diabrassC.P.bottletrap,15mmdiabrassC.P.Anglestopcockwith flange, 15mm dia brass C.P. coldwater connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors- toilets. Wash Basin 50 Supply & Fixingat sitein position 15mm dia C.P brass BIB COCKS long body with wall flangeincludingcuttingandmakinggoodthe wallswhereverrequired 51 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc.,complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 52 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 53 Supplying and fixing in positionC.P. Soap tray of size 150 x 150mm including cost of teak wood plug and C.P. screws. etc. complete complying with standard specification.(D) 54 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition,including testing for any leakages,etc.,complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 55 a) 40mm dia. 6kg class PVC pipes. 56 b) 50mm dia. 6kg class PVC pipes. 57 c) 75mm dia. 6kg class PVC pipes. 58 d) 110mm dia. 6kg class PVC pipes. 59 Supplying and fixing in position cost iron Nahini / Floor trap with Stainless steel grating / PVC nahini / Floor Trap with PVC Grating type of size 100 x 75 / 75 x 50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1;2;5 (One lime two sand and five aggregate ) brick jelly 40mm and finishing with cm 1;3(One cement and three sand) including dismantling masonary wherever found necessary and making good to the original condition and giving connections to the cast iron pipe etc, complete complying with standard specififcation and as directed by the departmental Officers. 60 Supply and fixing in position best quality PVC IS 4985 - CLASS-II - 4 Kg/Sqcm -Rain water pipes of various size having ISI mark and providing leak proof joints with such asBend, Tee Junction, door etc.,of approved qualityincluding fixing to the wall with special PVC /MS clamps, etc., and making connection to all sanitary fittings, wherever necessary and making chipping good to the original condition, complying with standard specification etc.,complete. 61 b).110mm dia. 4kg class pipes. 62 Supplying and fixing in position of the following dia PVC rain water gratings for rain water pipes ,of approved quality and varietyof various size confirming to ISS andincluding necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer. 63 110mm dia 64 Supplying and fixing in position of the following dia PVC specials such asPVC vent Cowl etc.,of approved quality and varietyof various size confirming to ISS amend providing leak proof joint etc., including necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer. 65 a)75mm Dia 66 b)110mm Dia 67 PART-C - EXTERNAL DRAINAGE 68 Soil/ Waste Pipes 69 Supply and fixing in position best quality PVC IS 4985 - CLASS- III - 6 Kg/Sqcm -Soil/ waste pipes of various size with approved quality and varietyof various size confirminghaving ISI mark and providing leak proof joints including erection of below groundwith excavation and refilling etc.,and making connection to Manholes /Gully trap,wherever necessary and making chipping good portion to the original condition,complying with standard specification etc., complete. 70 160mm dia. 6kg class III-pipes. 71 Supply, laying and erction of glazed stone ware gully trap (100 x 75 mm) with 100 mm dia, outlet including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm inside clear in brick masonry 230 mm thick, plaster with water proof cement mortar (1:3) 15 mm thick on both internal and external surfaces inside finished with floating coat of neat cement. The work including excavation to required depth of gully trap and refilling and making good in the surface withProviding and fixing SFRC frame and cover 400 x 400 mm (clear opening) complete complying with std.specification. 72 Supplying and Erection and construction of sewer chambers of required internal dimensions 600x600 upto 0.6 mtr.depth with 230mm brick masonry in C.M.1:5 thk of masonry over bed of1:2:4 R.C.C. 200 mm thk bove 100 mm thk P.C.C.1;3:6 Cement concrete foundations over sand bed of 100mm thk channelling in 1;2:4 cement concrete, plastering in 1:3 cement mortar for internal and external surface finished with floating coat of neat cement, the work including excavation for required depth of gully trap and refilling and making good in the surface with SFRC cover and frame 600x600mm (clear opening)complete complying with standard specifications etc., 73 Construction of rain water recharge well of 1200mm dia and depth upto 1500mm, in addition 110 dia special blue slotted pipe for bore well.pipe should be laid from bottom of ring well centre to below 1500mm as shown in the drawings,including all types of excavation, occur for pipe,filling of rain water harvesting materials with construction of R.C.C. ring and top 100mm RCC SLAB WITH 450X450mm perforated SFRC manhole and 230mm brick wall in 2height with below 300mm lengthx100mm thk P.C.C. as per the structural filling the filter media as per drawing. 74 Supplying and fixing of PVC water storage tank of best approved quality and make of super thick with lid ofcapacity of 2000 litres with accessories including giving necessary connection etc., complete as directed by the departmental officer. (The PVC water storage tank should be got approved by the Engineer before use on work)(TWAD- Pano:173) 75 provision for rainwater harvesting structure 76 Electrification 77 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) 78 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End 79 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End 80 Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.) 81 Supply and fixing of fancy glass shade and 7W / 9W LED bulb 82 Supply and fixing of single box type 440W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting 83 Supply and fixing of AC / DC 76mm buzzer / call bell suitable for 230 volts 50 c/s single phase AC supply on suitable TW board with push switch 84 Supply and fixing of 1200mm (48) AC ceiling fan complete with stepped electronic 300W regulator with 300mm down 85 Supply and fixing of 300mm (12) sweep (light duty) AC exhaust fan complete without provision of hole in the wall 86 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End 87 Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End 88 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earthconnection (For AC Plug) 89 Supply and fixing of 8 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 24 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 90 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40A DP MCB Isolator as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 91 Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipeconcealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of theconcealed portion with suitable colour 92 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. 93 Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVCrigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitablecolour 94 Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth Wire connection of 6 sq.mm copper wire with painting of suitablecolour 95 Supply and run of 1 of No.8 SWG GI wire for earth connection 96 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earthconnection 97 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm 98 Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2 x 1-1/2 x 1/4 rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1 x 1/4 with inter connection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with 1 No 63 Amp 30 MA Four Pole RCD / RCCB (Lower End) with suitable necessary connection with earth connection complete 99 Supply and fixing of 63A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only 100 Supply and fixing of 63A TPNMC switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing 101 Supply and fixing of brass cable gland for 2 x 16 sq.mm. PVC armoured LTUG cable with earth connection 102 Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection 103 Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 104 Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 105 Supply and Laying of 3 1/2 x 95 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 106 Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 107 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 108 Septic Tank 109 Earthwork for foundationsand depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soilincluding excavated earth. 110 Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification. 111 Laying the Plain Cement concrete 1:4:8(One cement four sand and eight brokenMachine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc.. 112 Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid) 113 REINFORCED CEMENT CONCRETE M25 1:1.5:3 mixusing 20mm machine crushed 20mm gauge hard broken granite stone jelly for all reinforced cement concrete works connected to this work excluding cenetering, shuttering and cost of reinforcement grills placed in position, but including laying, vibrating, curing and finishing, fixing fan clamps in the RCC floor and roof slab works wherever necessary and bearing surfaces of the wall at the sides and bottom of the slab, beams shall be finished smooth with cement mortar 1:3 (One cement and three sand ) and Kraft paper laid without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers. 114 Brick work in following Cement Mortar using best quality of Country Bricks of size 8-3/4 x 4-1/4 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 115 Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally and externally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent andas directed. 116 Supplying and fixing in position C.I.Manhole covers (heavy duty) mof various sizes of best approved quality and as per standard specificationsetc., complete.0.6X0.6M Size etc., complete. 117 Providing, machine mixing and laying on the P.C.C/ R.C.C. surface in approved panels of25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick)well vibrated,compacted including 45 X 3 mm glass dividing strip, fixed to correct level and finished smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost). 118 Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication. 119 Under Ground Sump 120 Earthwork for foundationsand depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soilincluding excavated earth. 121 Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification. 122 Laying the Plain Cement concrete 1:4:8(One cement four sand and eight brokenMachine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc.. 123 Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid) 124 Reinforced Cement Concrete 1:11/2:3 (One Cement, One and a half sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers 125 Providing and applying 10 mm thick Cement plaster in Cement mortar 1:3 ( One part of Cement and Three parts of Sand ),to finishing the exposed surfaces of R.C.C. items of works such as Roof (or) floor slabs, beams,and Sun shades etc.to correct plane and l 126 Providing, machine mixing and laying on the P.C.C/ R.C.C. surface in approved panels of 25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick)well vibrated,compacted including 45 X 3 mm glass dividing strip, fixed to correct level and finished smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost) 127 Supplying and fixing in position C.I.Manhole covers (heavy duty) of various sizes of best approved quality and as per standard specificationsetc.,complete.0.6X0.6M Size etc., complete. 128 PVC mould CI steps for sump 129 Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication. 130 Aluminium ladder for maintenance over the Roof top 131 Provision for lab interior 132 Tactile Flooring and Braille Sign Board 133 Provision for Sitting bench and Cubboard Arrangements 134 GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column BB for all works in this package}
Contract Date: Jun 13, 2026 Contract Value : 1.68 Crore
Local Bodies No of Bidders 2
10.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
11.
Public Administrative Department #11276744 Technical Bid
Tender for Labour Engaged For Desilting,Readjustment Of Manholes Covers, Diverting The Direction Of Water Dewatering During The Execution Of Work And Disposal Away From Site. , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead For Thickness Of Tiles Above 25 Mm And Upto 40 Mm. , Dismantling Dressed Stone Work Ashlar Face Stone Work, Marble Work Or Precast Concrete Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge , Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead. , Dismantling Of Flexible Pavement (Bituminous Courses) By Mechanical Means And Disposal Of Dismantled Material Upto A Lead Of 1 Kilometer, As Per Direction Of Engineer-In-Charge. , Dismantling Manually/ Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: Bituminous Road. , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge:1:4:8 Or Leaner Mix (I/C Equivalent Design Mix) , Demolishing Lime Concrete Manually/By Mechanical Means And Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing Brick Work Manually/By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge:In Cement Mortar , Demolishing Cement Concrete Manually/By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-Incharge: 15.2.1 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) , Demolishing Reinforced Cement Concrete Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Demolishing R.B Work Manually/By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. , Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: All Kinds Of Soil : , Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : , Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5 M In Width As Well As10 Sqm On Plan Including Disposal Of Excavated Earth, Leadupto50meterand Lift Upto 1.5M, As Directed By Engineer-In-Charge.All Kinds Of Soil : , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil : , Removal Of Excavated Mulba Dismantled Or Unserviceable Material From The Site Of Work By Mechanical Transport Or Animal Transport Or Otherwise Including Loading/Unloading(Complete Job) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.8 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With:1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts,Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etcupto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With.1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size) , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately.All Works Upto Plinth Level , Providing And Laying In Position Ready Mixed M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For All Leads, Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C. From Transit Mixer To Site Of Laying , Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement Including Cost Of Admixtures In Recommended Proportions As Per Is : 9103 To Accelerate/ Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of The Engineer- In - Charge. Note: - Cement Content Considered In This Item Is @ 330 Kg/ Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. All Works Above Plinth Level Upto Floor V Level , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For: Foundations, Footings, Bases For Columns , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs Andsteps Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For:Edges Of Slabs And Breaks In Floors And Walls , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Suspended Floors, Roofs, Landings, Balconies And Access Platforms. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Arches, Domes, Vaults Upto 6 M Span , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level With Cold Twisted Bar , Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works. , Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded , Providing And Laying River Bed Material On The Road Surface By Way Of Spreading The Same In Uniform Layer Not Exceeding 20Cm In Depth, Watering And Compacting With Vibratory Power Road Roller Of 8-10 Tonne Capacity Incl Carriage Of Material From Source To Site Of Work (All Leads , Lifts Complete).The Measurement Is To Be Taken Of Compacted / Finished Work. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. , Providing And Fixing 60Mm Interlocked Paver Tile Over A Layer Of Cement Mortar 1:4 Mix Incl Filling Of Joints With Cement Mortar 1:3 (Complete Job) , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Per Direction Of Engineer-In-Charge. 80 Mm Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. , 12Mm Cement Plaster Of Mix: 1 : 6 ( 1 Cement : 6 Fine Sand) , 12Mm Cement Plaster Of Mix: 1 : 4 ( 1 Cement : 4 Fine Sand) , Brick Work With Common Burnt Clay (Non-Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand) , Extra For Brick Work With Common Burnt Clay Bricks/Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level , Tile Brick Masonry With Common Burnt Clay Tile Bricks Of Class Designation 10 In Foundation And Plinth Including Curing Complete In: Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Fine Sand) , Providing And Laying Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site By Tippers, Laid Over A Previously Prepared Surface With Paver Finisher Equipped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specifications And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Ofgrade Vg-30 @ 3.5% (Percentage By Weight Of Total Mix) Prepared In Drum Type Hot Mix Plant Of 60-90 Tph Capacity , Supplying,Stacking, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Bound Macadam (Wbm-Iii) With Graded Crushed Stone Aggregate Of Size 53Mm To 22.4 Mm In Uniform Thickness,Hand Picking , Rolling With Vibratory Roller 8-10 Tonne Capacity In Stages To Proper Grade And Camber,Applying And Brooming Requisite Type Screening / Binding Material To Fill Up Interstices Of Coarse Aggregate,Watering And Compacting To The Required Density.Complete Job , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications. On Bitumen Surface @ 0.50 Kg/Sqm. , Hand-Packing Stones In Wire-Crates; Excluding Cost Of Crates And Stones , Providing And Applying Tack Coat Using Hot Straight Run Bitumen Of Grade - Vg-30, Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler, Cleaning And Preparing The Existing Road Surface As Per Specifications.16.38.1 On W.B.M. @ 0.75 Kg/Sqm. , Providing And Laying Seal Coat Of Premixed Fine Aggregate (Passing 2.36 Mm And Retained On 180 Micron Sieve) With Bitumen Using 128 Kg Of Bitumen Of Grade Vg-30 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface Including Rolling And Finishing With Road All Complete , 2.5 Cm Premix Carpet Surfacing With 2.25Cum And 1.12 Cum Of Stone Chippings Of 13.2 Mm And 11.2Mm Size Respectively Per 100 Sqm And 52 Kg And 56 Kg Of Hot Bitumen Per Cum Of Stone Chippings Of 13.2 Mm And 11.2 Mm Size Respectively Including A Tack Coat With Hot Straight Run Bitumen Including Consolidation With Road Roller Of 6 To 9 Tonne Capacity Etc. Complete (Tack Coat To Be Paid For Separately). Vwith Paving Asphalt Grade Vg-30 With No Solvent , 10Cm Thick (Average) Mud Phaska Of Damped Brick Earth On Roofs Laid To Slope Consolidated And Plastered With 25 Mm Thick Mud Mortar Mixed With Bhusa At 35Kg Per Cum Of Earth And Gobri Leaping With Mix 1:1 (1 Clay: 1 Cow Dung) And Covered With Specified Tile Bricks Grouted With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Mixed With 2% Of Integral Water Proofing Compound By Weight Of Cement And Finishing Neat. 12.25.1 With Common Burnt Clay (Non Modular) Brick Tiles Of Class Designation 10.0 , Providing And Fixing Precoated Galvanized Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge) 0.50 Mm (+ 0.05 %) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories0.50 Mm (+0.05 %) Total Coated Thickness, Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling/ Self Tapping Screws Complete : 12.24.1 Ridges Plain (500 - 600Mm) 12.24.2 Flashings/ Aprons.(Upto 600 , Providing And Fixing 1Mm Thick M.S. Sheet Door With Frame Of 40X40x6mm Angle Iron And 3Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer. Using Flats 30X6mm For Diagonal Braces And Central Cross Piece. , Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 2 Mm Thick , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade On New Work (Two Or More Coats Applied @ 1.67 Liter/10Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10Sqm) , Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1Cement :4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete Size Of Tile 600X600 Mm , Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) . Dark Shade Using Ordinary Cement. , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Bib Cock Of Approved Quality Conforming To Is : 8931 , Providing And Fixing 15 Mm Nominal Bore C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms. , Pvc Bend , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing Of Pvc Pipe With All Fitting Complete Job , Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. (I) Single Socketed Pipes 75 Mm Diametre , Providing And Fixing Of Pvc Including All Fitting With Complete Job , Providing And Fixing Of Towal Ring With All Fitting With Complete Job , Providing And Inserting Upvc Pipe ( Working Pressure4kg/ Cm2) Single Sockted Pipe 110 Mm Dia , Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc.: Internal Work-Exposed On Wall 15 Mm Dia. Nominal Bore , Dumping Of Stone Including Cost Of Stone Filling, Including Supply Of Stone And Carriage Complete Job , Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank , Supply Of Wire Crates Of Approved Mesh Including Weaving Binding Sides And Partitionsand Binding Top After Filling Complete Job. , Extra For Every Additional Lift Of 1.5 M Or Part There Of Beyond 1.5 M Height For Hand-Packing Of Stones In Wire-Crates , Providing And Fixing Of Weep Hole With Pvc Pipe Of 100 Mm Dia Complete Job , Providing And Fixing Of Weep Hole With Pvc Pipe Of 110 Mm Dia Complete Job , Stone Work In Super Structure Upto Floor Five Level In Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand) Including Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: White Sand Stone , Stone Work Plain Ashlar In Super Structure Upto Floor Five Level In Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand) Including Centering, Shuttering And Pointing With Cement Mortar 1:2 ( 1 White Cement: 2 Stone Dust) With An Admixture Of Pigment Matching The Stone Shade And Curing Complete: Red Sand Stone B White Sand Stone , Plastering With Lime Surkhi Mortar Of 20Mm Thickness Including Preparation Of Mortar, Tamping, Curing, Prepared By Traditional Methods Including Mixing Of Gur, Tamarind Water, Dal Etc. As Per Tradition, The Work Is To Be Done With All Leads And Lifts, Surfaces To Be Plastered Shall Be Thoroughly Cleaned Of All Dust, Grease, Oil Etc. All Surfaces Should Be Kept Damp During The Progress Of Work. The Engineer-In-Charge Will Inspect And Approve All Preparatory Work. Curing To Be Done For 21 Days By Means Of Spraying , Roviding And Applying Lime Kara 1:2 (1 Lime: 2 Zikki Powder) Grinding Mortar With Grinding Mill/Manually On Lime Base, On All Flat Surface In Two Coats. First Coat Applying 3 To 4 M Thick And Curing Properly At Least 7 Days, Second Finishing Coat Done After 7 Days Of Previous Coat As Per Tradtional Practice (Thickness Not More Than 6Mm). , Providing Protective Coating Of Water Repellent Siloxane (Transparent In Color) Through Brush Or Spray Until Complete Impregnation Over Completely Cleaned And Dried Stone Or Plastered Surface To Reduce The Absorption Of Water , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Meter Lead As Per Direction Of Engineer-In-Charge. , Providing And Fixing Steel (White Powder Coated) Crescent Lock For Upvc Sliding Window/ Door With Necessary Screws Etc. Complete , Providing And Fixing Of Steel Banches , Providing And Fixing Glass Panes With Putty And Glazing Clips In Steel Door/ Windows/ Clerestory Window All Complete With 5.00Mm Thick Glass Panes Complete Job , Providing And Fixing Of Soap Dish , Providing And Fixing Inaugration Plate Including Writing Etc. Complete Job. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Sand For An Avg Distance Of 5 Kms , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Stone Aggrigate For An Average Distance Of 7 Kms By Mt. , Carriage Of Materials By Mechanical Transport Including Loading / Unloading & Stacking Complete Brick For An Avg Distance Of 5 Kms , Electrification Items : Supply, Installation, Testing & Commissioning Of 5 Mtr Height Decorative Pole Made Of Galavnised Mild Steel Pipe Duly Polyurethane (Pu) Paint Coated With 1 Mtr. Long Double Arm Designer Bracket Is Made Of Round Tube Conforming To Is 1161. The Pole(Od Of 114.3Mm And Thickness-3.6Mm) With Bracket Is Given Pre-Treatment And Finished With Pu Paint Giving It A Pleasing Appearance And Antique Finish. Pole Shall Be Available To Hot Dip Galvanize The Tube Before Painting. Foundation Bolt Size Shall Be 20X600x4nos. With Base Plate Size 300X300x12mm. A Door Is Provided With Electrical Accessories (Connector, Bakelite Sheet And 6 annual periodical maintenance Single Pole Mcb, Cable Looping Termional For 4X4/6Sqmm Copper Cable). Aluminium Casting In Golden Ring Form At Bottom, Middle, Top Of The Pole. The Pole Will Be Supplied With Brackets And Luminaire Combinations To Suit The Requirement. Branding Name Shall Be Embossed At The Bottom Near Junction/Mcb Box. Sticker Not Allowed In The Form Of Company Branding. Pole Shall Be Supplied With Outdoor Post Top Luminaire Of 45 Watt Ip67 Mounted In Suspension Type Having An Approximate Size Of 460Mm Outer Diameter And 635Mm Height, Housing - Aluminium With Designer Steel Aesthetic Crown, Optical Grade Opal Injection Moulded/Clear Polycarbonate Diffuser And Graphite Grey Uv Resistant Colour,Constant Current Electronic, Driver Provided With High Voltage ,Open & Short Circuit Protection And Ambient Temperature -10C To +40C. Supply 150V- 240V Power Factor 0.95 ,Thd ≤ 20% Internal Surge Protection Of 4Kv With Following Specification Of Light Engine For 45W : 4500Lumens, Cct 3000K ±500 Cct ,Cri 70 And Lumen Maintenance Of L70 At 50000 Hours Ip 65 Connectors,Accessories Etc Complete With All Repects. Design Of Pole Should Be Such That It Should Maintains Proper Illumination On Both Side.(Analysis Attached) , Led Flood Light, Powder Coated Pressure Die Cast Aluminium (System Lumen Efficacy ≥105 120 Lm/Watt). Supplying, Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separate Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 0C To 50 0C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.≥0.95, Ip-66,Ik-10, Cri 70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr -15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement., Suitable Tilt Able Fitting, Life Time (Led, Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin) , Sdcm(Standard Deviation Color Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofrelevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy ≥105 120 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-Incharge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). 250 Watt , Led Linear Profile (Ac) Led Rgb/Rgbww/ Rgbnw/Rgba/Rgbw, Linear Profile / Wall Washer Luminaire For Façade Lighting With Aluminium Extruded/ Die Cast Housing With Inbuilt Driver Of Following Wattage. Wattage Per Meter 25W , Supply, Installation, Testing & Commissioning Of 1.1 Grade, 4Cx10 Sqmm Al. Armoured Xlpe Sheathed Cable Including Termination (Along With Lugs) , Providing And Fixing Of Gi Pipe 50 Mm Dia , Feeder Pillar 1 Phase 2 Wire, 415V, 1Nos Of 100 Amps Incoming Sp Mccbs Fitted With Outgoing 04 No 32 Amps Sp Mcbs For Service Connections, Distribution Service Pillar Suitable For Outdoor Installation , Made Out Of Crca Sheet Painted Through 7-Tank Process With Pu Painted Busbars 2P, Aluminium With Heat Shrinkable Sleeves And Adequate Capacities Complete With All Accessories 4 Way Distribution Service Pillar. Support Galvanised Angle Frame And Legs (40Mm X 40 Mm X 3Mm) For Distribution Feeder Pillar With Leg Height 1M With 0.3M In Soil Approx [email protected] Per Mtr, Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip.Cement Grouting For Support Angle Legs, Spares @ 3%, Erection Charges @10%, Overheads @ 5% (1.0% T&P 0.5% Storage And Handling , 3% Contingency And Safety Equipments, 0.5% Insurance) And Turnkey Factor @25% With Astronomical Timer. , Earthing With Copper Earth Plate 600Mm * 600Mm * 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc. With Charcoal/Coke And Salt As Required. , Wiring For Light Point/Fans Point/Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insıslated Copper Conductor Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gf Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group-A , Add For Vetting Charges Consultency And Contigencies @ 2.5 %
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Jammu And Kashmir View Result →
12.
Tourism #11266721 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Columns, Pillars, Posts & Struts (Circular Or Curved In Plan) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Windows With Three Tracks And Three Shutters Sliding Windows With Tubular Frame Sections Powder Coated With Pure Polyster Powder Of Thickness 15-80 Microns With Approved Standard Acessories Such As Ball Bearing Rollers Concealed Lock, 6Mm Plain Clear Glass With Epdm Beading Etc. , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Extra For Providing Opening Of Required Size & Shape For Wash Basin/ Kitchen Sink In Kitchen Platform, Vanity Counter And Similar Location In Marble/Granite/Cuddapah Stone Work, Including Necessary Holes For Pillar Taps Etc. Including Moulding, Rubbing And Polishing Of Cut Edges Etc. Complete. , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid Plain White Makrana Marble Slab 25 Mm Thick , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing & Fixing In Position Double Skin Roof With Zincalume/ Galvalume Colour Coated & Bare Profile Sheet With Subtle Square Fluting Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respect. Top Sheet-The End Rib Shall Be Designed For Anti-Capillary Action. The Feed Material Should Be Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 43.5% Zinc &1.5% Si) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides) With Quality Paint Coat As Per As/Nzs 2728 Type 3-4. The Paint Shall Have A Total Coating Thickness Of Nominal 35 Μm, Comprising Of Nominal 20 Μm Exterior Smp Coat On Top Surface And Nominal 5 Μm Reverse Backer Coat On Back Surface Over Nominal 5 Μm Primer Coat On Both Surfaces Of Approved Colour Shade. Total Coated Thickness (Tct) Should Be 0.50Mm. Total Painted Thickness (Tpt) Should Be In Addition To 0.50Mm. The Steel Sheet Shall Be Fastened With Nominal 40 Μm Zinc Coated Or Nominal 25 Μm Zinc-Tin Alloy Coated, Hex Head, Self-Drilling Screw As Per As 3566-2002 Class 3 Fasteners Of Approved Make With Epdm Washer As Per The Requirement Considering The Profile Shape And Design Load. The Fastener Size Shall Be Calculated As Per The Design Or Manufacturers Recommendations. The Profile Sheet, Fastener Size Etc. Shall Be Approved By The Engineer. The Sheeting Should Be With Minimum 200Mm Lap & Waterproof With Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed Z-Sub Girt - Roll Formed Section 50X50x50x1.50 Tct, 120Gsm Galvanised, High Strength (345 Mpa), Approximate Wt. 1.85 Kg/R.M. Fixed With Self Tapping Screws Glass Wool Insulation With Fsk Facing 50Mm With 24 Kg/M3 Density In Between 2 Sheets. Liner Sheet-Bare Galvalume/Zincalume Roofing Sheet Of Same Profile As Top Sheet. The Feed Material Is Of Manufactured Out Of Nominal 0.45 Mm Base Metal Thickness (Bmt) (0.47 Mm Tct), Hi-Strength Steel With Min. 550 Mpa Yield Strength, Metallic Hot Dip Coated With Aluminium-Zinc Alloy (55% Aluminium, 45% Zinc) As Per As 1397 - Zincalume Az150 (Min. 150 Gms/Sq.Mt Total On Both Sides), Passivated & Resin Coated. The Feed Material Should Have Coil ManufacturerS Product Details Marked At Regular Interval For Confirming Genuinity Of The Material. Complete As Per The Directions Of The Engineer. The Steel Manufacturers Test Certificate For The Chemical & Mechanical Properties Of Steel Must Be Submitted For Approval Prior To Installation. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Mts. Lead. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Dismantling Asbestos Sheet Roofing Including Ridges, Hips Valley And Gutters And Stacking The Material Within 50 Meters Lead. , Dismantling Tiled Roofing (Mangalore Or Pot Or Country Tiles) With Battens Etc. Complete Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Taking Out Existing cement concrete Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Of Reinforced Cement Concrete Gril Of Size 1.00 M X 0.6 M Ht Placed And Fixed On Coping Band For Compound Wall As Per Detailed Drawing Etc Complete , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka, Padma And Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Corner (Ht 4.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 450 Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Maximum 900Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height, 750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Featuring A 60Mm Height, 750Mm Width Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, ( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height,( Maximum 4 Hands & 4 Ayaudhas ) Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple Small Stupi ( Bagil Paik ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2400Mm X 2400Mm X 1800Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Proving And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type W.C. Pan) Size 580 Mm With 100 Mm Sand Cast Iron P. Or S Trap 10 Litres High Level P.V.C. Flushing Cister (Of Approved Make) With Fittings, Rack Bolts 32 Mm Diameter P.V.C Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon Pull Complete Cutting And Making Good The Walls And Floors Where Required Long Pan Pattern W. C. Pan , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Pillar Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 15Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 45-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70b50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-18 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (C) 50 To 100 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Isolator 2 Pole 40A, Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 20 Led 40W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Ip 66 Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Type/Ip65 12W Ceiling-Mounted Led Downlight Having Extruded And Die Cast Aluminium Housing With High Corrosion Resistance Surface Finish With Integral Control Gear And Beam Angles - Narrow, Medium, Wide ,Complete With All Required Accessories .Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii)) , Supply Of 2Kva ,1Ph In - 1Ph Out True Online Ups System In Standalone Configuration With Advance Dsp Based Technology Double Conversion Igbt Rectifier And Igbt Based Inverter Ups System With Cabinet And Smf Battery Backup For 60 Mins. Using 12V Batteries Including Battery Protection M.S Rack Suitable Dimension, Standard Rating Cable For Interlinks Cable And D.C Cable Up To Standard Length In Mtrs From Ups To Batteries Including Labour Charges For Installation Testing And Commission And Carrying Charges.(With Out Isolation Transformer)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
13.
Health and Family Welfare #11215965 AOC
Tender for Supply Of Furniture For Boys Hostel -Iii At Nliu, Bhopal , Supply Of Furniture , Providing Steel Almirah Mirror Having Overall Size 910W(+ 05Mm) X 500D(+ 05Mm) X 1980 (+ 05Mm) H , Top , Bottom , Side Panel Made Up Of 1Mm Thick Crca Sheet Powder Coated , Legs Or Pedistal And Shelves Made Up Of 1.2Mm Thick Crca Sheet Powder Coated And Height Of Thelegs Or Pedistal Should Be 130 Mm(+ 05Mm), Shutter Made Up Of 1Mm Thick Crca Sheet Powder Coated , No Sharp Edges Of Almirah Ends, All Shelve Rack Divided Into Equal Parts , Door Die Cast Chrome Plated Handles Fitted With Washer & Double Nut , Handles Ring Made Of Pvc Cap , Almirah All Metallic Panels Screw With Nut & Bolt, Metal Pipe & 07 Tank Treatment With Minimum 50 Micron Powder Coating. Shelving Height-Wise Adjustable Shelf Mounting: Uniformly Distributed Load Capacity Per Each Full Shelf Is 40 Kg Maximum. Three Horizontal Shelf Partitions Are Provided Made Of 1.2 Mm Crca Steel Top Shelf Clear Space Height From Bottom Is 1050 Mm And Second Shelf Height From Bottom Is 700 Mm And Third Shelf Height 350 Mm; 1Mm Crca Sheet Fitted With Heavy Duty 25Mm. Hanging Rod 02 Nos. 25Mm Dia Med Guage Ss Capsule Pipe Is Provided On The Top In The Centre. Locking & Handle - S.S. Handle With 2 Way Locking Mechanism With Shooting Rod/Bolt Arrangement. 5Mm Tk Plain Mirror (Make-Modi, Asahi, Saint Gobain) Of Size 400 Mm X 1200 Mm Is To Be Provided On One Flap Fixed With The Help Of M.S. Clips/Beading As Per Approval. Whole Steel Structure Is Epoxy Powder Coated To The Thickness Of 50 Microns In Approved Shade/Color And Texture. The Work Includes All Required M.S. Hinges, Handle, Lock, Bolts And Hardware Of Good And Approved Quality Etc. Compete. This Job Includes All Installation, Material & Labor Etc. Complete And Nothing Will Be Paid Extra For Execution/Installation Of The Item. Items Should Have 5-Year Warranty. , Providing Hostel Bed Overall Size 1980W(+ 10Mm) X 960D(+ 10Mm) X 810H(+ 10Mm), Hostel Bed Made Of Prime Quality Round Metal Pipe Of Size 38Mm Dia 1.2Mm & 50X25mm Thick Crca Rectangular Pipe 1.2Mm Thick, Head Rest Designed With 38Mm Dia With 25Mm Round Support Pipes For Supporting Pillow Having Height Of 810Mm, Bed Mattress Structure Made From 50X25x 1.2 Mm & 25X25x1.2 Mm Pipes, Mattress Support Panel Made Of 12Mm Thick Isi/Bis Grade Bwp Plywood, Mattress Panel Height From Floor Should Be Of 450Mm, Four Number Of Supports Of Size 25X25x1.2Mm Are Given To Mattress Panel, Additional 25X25x3mm Angle Used Under Ply Along With Headboard & Footboard Having Length Of 100 Mm Of Each, The Complete Structure Should Be In Knockdown Construction And Assembled With Nut & Bolts, All Open Edges Of Pipes Should Be Covered By Good Quality Ppcp Shoes/Caps, . All Metal Components Should Be Pre-Treated With Zinc Phosphating In Minimum 07 Tank Process And Then Powder Coated With Epoxy Polyester With Approved Shade, Thickness Of Coating Should Be Minimum 50 Micron. .Items Should Have 5 Year Warranty. , Providing Study Table Overall Size 900W(+ 05Mm) X 600D (+ 05Mm)X 750H(+ 05Mm) , Table Top Made Up Of 16Mm Thick Bwp Termite Proof Ply Wood , 0.8Mm Mica On Top And 0.6 Mm Balancing Mica On Bottom Isi/Bis Standard As Applicable For The Product With 2Mm Thick Pvc Edge Bending , Understructure Made Of Crca 40X40x1.2Mm Square Metal Pipe Duly Powder Coated, Understructure Crca Square Metal Pipe 40X40mm X 1.2Mm Thick Made In Knockdown Condition, Table Provided With One Side Storage Single Drawers Fixed Pedestal With Depth Of 575Mm(+/- 05Mm) ,Storage Should Be Of Size 300 Mm (W) And 120 (H). The Storage Support Ms Pipe25x25x1.Mm . Storages Made Of 1.2Mm Thick Crca Metal Sheet Duly Powder Coated , All Opend Ends Closed With Ppcp Caps & Shoes, All Metal Parts Shall Be Welded Properly Strongly And Conformity With Regulations, The Table Structure Should Be In Knockdown Condition, All Metal Components Should Be Pre-Treated With Zinc Phosphating In Minimum 11 Tank Process And Then Powder Coated With Epoxy Polyester With Approved Shade, Thickness Of Coating Should Be Minimum 50 Micron.Items Should Have 5 Year Warranty. , Supplying And Placing In Position Of Study Chair Size: (W) 550Mm(+ 10Mm) X (D) 565Mm(+ 10Mm) X (H) 815Mm(+ 10Mm) Seat & Back Of Chair Is Made 12Mm Thick Hot Pressed Isi/Bis And Bwp Grade Plywood Cushioned With Pu Moulded Foam Fabric Upholstery, Armrest: Pu Paded Armrest Fixed On Main Frame. Understructure Size Pipe Thickness 1.2Mm, Pipe Size Is ± 40Mm (W)X ± 20Mm (D)Oblong Pipe. Material-Powder Coating, Thickness Of Pu Foam- 40-50,Under Structure Frame Made Of Ms Pipe With 14 Gauge Thickness Duly Powder Coated With Plastic Bushes. Back Type-Medium Back, Density Of Pu Used In Seat(Kg Per Cubic Meter) 40=50 Thickness Of Pu Used In Seat(Mm) 40=50 Support To Be Provided By Metal Angle Width Wise Under The Seat Of Chair. Items Should Have 5-Years Warranty , Providing And Fixing Dining Table 8-Seater With Stool. Table Top Made Of 18Mm Isi/Bis, Bwp, Water And Termite Proof Plywood Molded With 1 Mm Thick Ss Sheet With 304 Grade All Over Size Of Table Should Be 2400L(+ 10Mm) X 900W(+ 10Mm) X 800H Table Top Size 2400L X 900W. Understructure Made Of Prime Quality Crca 50 X 50Mm X1mm Square Metal Pipe Duly Powder Coated Understructure Crca Metal Pipe 50 X 50Mm X With 1.6 Mm Thick Four Side Welded With Vertically Metal Pipe Legs Of The Table Hard Rubber Shoes Understructure Crca Square Metal Pipe 50 X 50Mm With 1.6 Mm Thick All Side Welded With Vertically & Horizontally Metal Pipe Powder Coated. Seat Size(On Top) 300Mm Dia 0.8Mm Thick 304 Grade Ss Seat Molded With 18Mm Thick Plywood Seat Height From Ground 450Mm Seat Understructure Made Of 50 X50 Square Metal Pipe With 1.6Mm Thick Powder Coated. Legs Of The Table Closed With Hard Rubber Shoes. It Should Have 8 Seats All Frames Square Pipe Closed With Pvc Caps. All Metal Pieces Shall Be Welded Properly Strongly And Conformity . Thickness Of Coating (60-80) Micron. Support At The Bottom Of Table Top Should Be Provided Width-Wise By Properly Welded With Metal Angles Support At The Bottom Of Table Top Provided Depth-Wise By Properly Welded With Metal Angles. Items Should Have 5 Year Warranty.
Contract Date: Jun 05, 2026 Contract Value : 58.61 Lakh
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
14.
Power #11209663 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 3995405; 3995405; Service Provider-Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work. 15 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work20 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 25 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 32 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 40 Mm Dia. Nominal Bore Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc.External Work 50 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 15 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 20 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 25 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 32 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 40 Mm Dia. Nominal Bore Same As Above But For Internal Work (Exposed On Wall) 50 Mm Dia. Nominal Bore Providing & Fixing Full Way Stop Cock/G.M. Gate Valve Of Following Dia With Wheel, I.S.I. Mark Heavy Duty. Including Supply Of All Materials Labours, T&P Required For Proper Completion. 15 Mm Dia. Nominal Bore Providing & Fixing Full Way Stop Cock/G.M. Gate Valve Of Following Dia With Wheel, I.S.I. Mark Heavy Duty. Including Supply Of All Materials Labours, T&P Required For Proper Completion. 20 Mm Dia. Nominal Bore Providing & Fixing Full Way Stop Cock/G.M. Gate Valve Of Following Dia With Wheel, I.S.I. Mark Heavy Duty. Including Supply Of All Materials Labours, T&P Required For Proper Completion. 25 Mm Dia. Nominal Bore Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :15 Mm Nominal Bore Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore Providing And Fixing Unplasticised P.V.C. Connection Pipe With Ptmt Nuts, Collar And Bush Of Approved Quality And Colour. 15 Mm Nominal Bore With 45 Cm Length. Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank Isi : 12701 Marked With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank Providing And Fixing Brass Bib Cock Of Approved Quality :15 Mm Nominal Bore Supply And Fixing Of 15Mm Dia Ci/P.V.C. Bib Cock Including Replacing Of Old Bib Cock Complete. Providing & Fixing Of 110 Mm P.V.C. Pipe 6 Kg/Cm2 Specials Such As Tee, Bend, Socket, Elbow Etc. Including Cutting Excavation Of Trenches Its Back Filling After Testing The Pipe Line, Watering, Ramming Etc. Complete Including Disposal Of Surplus Earth From The Site Up To 100 Metre As Per Direction Of Engineer-In-Charge As Required For Proper Completion Of Work. Providing & Fixing 15 Mm Dia C.P. Pillar Cock Of Approved Make Including Cost Of All Materials, Labours T&P Etc. Required For Proper Completion Of Work. Providing & Fixing Suitable P.V.C. Washer In Bib/Stop/Pillar Cock, Including Cost Of Washer, Labour T&P Etc. Providing And Fixing G.I. Union 15 Mm Nominal Bore Each Union In Existing G.I. Pipe Line, Cutting And Threading The Pipe And Making Long Screws Including Excavation, Refilling The Earth Or Cutting Of Wall And Making Good The Same Complete Wherever Required :15 Mm Nominal Bore. Same As Above But For G.I. Tee, Socket, Elbow, Bend Etc. Upto 50Mm Dia Providing And Fixing White Vitreous China Water Closet Squatting Pan (Indian Type) But Orissa Pattern W.C. Pan Of Size 580X440 Mm Providing And Fixing White Vitreous China Squatting Plate Urinal With Integral Rim Longitudinal Flush Pipe. Providing And Fixing White Vitreous China Wash Basin Including Making All Connections But Excluding The Cost Of Fittings :Flat Back Wash Basin Of Size 550X400Mm. Providing And Fixing Ptmt Waste Coupling For Wash Basin And Sink, Of Approved Quality And Colour.Waste Coupling 38 Mm Dia Of 83 Mm Length And 77Mm Breadth, Weighing Not Less Than 60Gms. Providing And Fixing P.V.C. Low Level Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete.10 Litre Capacity - White Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. Providing & Fixing :100 Mm Sand Cast Iron Grating For Gully Trap. Repair Of Leakage In G.I./C.I. Pipe Line Of Following Dia. Including Necessary Excavation/Dismantling Relaying Of Pipe And Refilling Of Trenches Etc. Including Replacement Of Nuts, Bolts, Washer And Filling Etc. Complete 20 Mm To 40 Mm Dia Pipe Repair Of Leakage In G.I./C.I. Pipe Line Of Following Dia. Including Necessary Excavation/Dismantling Relaying Of Pipe And Refilling Of Trenches Etc. Including Replacement Of Nuts, Bolts, Washer And Filling Etc. Complete 50 Mm To125 Mm Dia Pipe Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2.6.1 All Kinds Of Soil Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level .1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). Same As Above But C.C.1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) In Superstructure For Closing Cavity 5 To 7.5 Cm Wide In Cavity Wall Complete With 10 Cm / 11.4 Cm Wide Bitumen Felt Type 3 Grade 1. Brick Work With Non Modular Fly Ash Lime Bricks (Falg Bricks) Conforming To Is:12894, Class Designation 10 Average Compressive Strength In Super Structure Above Plinth Level Up To Floor V Level In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) 12 Mm Cement Plaster In Fine Sand Of Mix With 1:6 (1 Cement: 6 Fine Sand) Cement Concrete Flooring 1:2:4. With 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate. Attending Of Petty Maintenance Service Like Plumbing, Welder, Mason And Carpenter Services With One No. Plumber/Welder/Mason/Carpenter With One No. Helper Per Hour. Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete :25 To 40 Mm Nominal Bore.Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main.15 Mm Nominal Bore Providing And Fixing C.P. Brass Stop Cock (Concealed) Of Standard Design And Of Approved Make Conforming To Is:8931.15 Mm Nominal Bore. Providing & Fixing Bottle Trap Of C.P. Brass Including Cost Of All Materials, Labour, T&P Etc. All Complete. Providing And Fixing Kitchen Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P. Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required .White Glazed Fire Clay Kitchen Sink Of Size 600X450X250 Mm. Providing And Fixing Soil, Waste And Vent Pipes Of 100 Mm Dia. Centrifugally Cast (Spun) Iron Socket & Spigot (S&S) Pipe As Per Is: 3989. Same As Item Above Above But For 75 Mm Dia. Centrifugally Cast (Spun) Iron Socketed Supply & Fixing C.P. Brass Bib Cock Heavy Quality 15 Mm Dia (400 Gms) Isi Mark Including Supply Of All Material, Labour And T&P Etc. Required For Proper Completion Of Work. Providing And Fixing Bend Of Required Degree With Access Door, Insertion Rubber Washer 3 Mm Thick, Bolts And Nuts Complete Of 100 Mm Dia. With Sand Cast Iron S&S As Per Is 3989 Same As Item Above Above But For 75 Mm Dia And .Sand Cast Iron S&S As Per Is- 3989 Providing Lead Caulked Joints To Sand Cast Iron/Centrifugally Cast (Spun) Iron Pipes And Fittings Of Diameter Of 100 Mm. Same As Item Above Above But For 75 Mm Dia. Same As Item Above Above But For 50 Mm Dia. Providing And Fixing Trap Of Self Cleansing Design With Screwed Down Or Hinged Grating With Or Without Vent Arm Complete, Including Cost Of Cutting And Making Good The Walls And Floors .100 Mm Inlet And 100 Mm Outlet.Sand Cast Iron S&S As Per Is: 1729. Cleaning Of Septic Tank Including Disposal Of Waste Outside The Area As Per Direction Of The Engineer Incharge Including Cost Of Removing Septic Tank Cover And Replacing Cover In Its Position Including Cost Of All Labour T&P Etc. Required For Proper Completion Of Work. Same As Above Item But For Inspection Chamber. Repair & Adustment Of Aluminum Doors And Windows For Proper Functioning By Skilled Mechanic Including All Labour T&P Etc. Required For Proper Completion Work. Supply & Fixing Of Brass Polised Hydraulic Door Closure Of Standar Size And Approved Quality In Door Shutter Including Cost Of All Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Conforming To Is : 6315, Having Brand Logo Embossed On The Body / Plate With Double Spring Mechanism And Door Weight Upto 125 Kg., For Doors, Including Cost Of Cutting Floors , Embedding In Floors As Required And Making Good The Same Matching To The Existing Floor Finishing And Cover Plates With Brass Pivot And Single Piece M.S. Sheet Outer Box With Slide Plate Etc. Complete As Per The Direction Of Engineer-In-Charge.With Stainless Steel Cover Plate Minimum 1.25 Mm Thickness. Renewing Glass Panes, With Putty And Nails Wherever Necessary Including Racking Out The Old Putty:Float Glass Panes Of Thickness 5.5 Mm Same As Item Above But 4 Mm Thich Float Glass Panes. Filling The Gap In Between Aluminium Frame & Adjacent Rcc/ Brick/ Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Completeupto 5Mm Depth And 5 Mm Width. Providing & Fixing Fully Glazed Anodized Aluminum Fixed Glazing With Hindalco Or Equivalent Extruded Standard Sections Of Various Thickness Show In Extruded Standard Sections Of Various Thickness Shown In Drawing Joints Mitered And Jointed As Shown In Drawing Including Providing And Fixed Of 5.5 Mm Thick Glass With Neoprene Beading All Round. The Minimum Thickness Of Anodizing On All Aluminum Sections Should Be 20 Micron With A (+) 2 Microns Tolerance. The Rate Should Include The Cost Of Fixing Of All Frame To Teak Wood Frame Or With Masonry/Rb/Rcc Structure By There Of Starting From 100 Mm Above The Bottom In Vertical Member Excluding Cost Of Teak Wood Frame. But Including Cost Of All Other Materials, Labour T&P Etc. Complete Required For Proper Completion Of Work. Same As Item Above But For Openable Window Portion As Shown In Drawings, Including Providing & Fixing Aluminum Hinges Of Heavy Quality And All Other Fitting Like Concealed Tower Bolts Handles Etc. As Per Direction Of Engineer-In-Charge Required For Proper Completion Of Work. Same As Item Above But For Openable Gate/Doors Portion As Shown In Drawings Including Providing And Fixing Pivots Of Heavy Quality And All Other Fittings Like Concealed Approved Tower Bolts, Bush Plate (As Shown In Drawing) And Approved Standard Brass Body With Brass Components 6 Levers Heavy Duly Concealed Lock Etc. Required For Proper Completion Of Work. Providing & Fixing Top Cover Of Rolling Shutters Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Providing And Laying Ceramic Glazed Floor Tiles 300X300 Mm (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown Laid On 20Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigments Etc Complete. Providing Corrugated G.S. Sheet Roofing Including Vertical/Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Up To Any Pitch In Horizontal/ Vertical Or Curved Surfaces) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.1.00Mm Thick With Zinc Coating Not Less Than 275Gm/M². Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J. Or L Hooks, Bolts And Nuts 8 Mm Dia. G.I. Limpet And Bitumen Washers Complete. 0.80Mm Thick With Zinc Coating Not Less Than 275Gm/M². Providing Non-Asbestos High Impact Polypropylene Reinforced Cement 6Mm Thick Corrugated Sheets (As Per Is: 14871) Roofing Up To Any Pitch And Fixing With Polymer Coated J, Or L Hooks, Bolts And Nuts 8Mm Dia. G.I. Plain And Bitumen Washers Or With Self Drilling Fastener And Epdm Washers Etc. Complete (Excluding The Cost Of Purlins, Rafters And Trusses), Including Cutting Sheets To Size And Shape Wherever Required. Providing Jack Hammer With Compressor Its Lead And Operator For Making Hole In Slab And Breaking R.C.C. And Exposing Existing Reinforcement And J.C.B Machine With Driver/Operator Fuel Hire Etc. Complete. Providing And Fixing 3Mm Thick Translucent White Acrylic Plastic Sheets Of Approved Quality In False Ceiling Or Window Pan Up To Any Elevation. Providing And Fixing 6 Mm. Thick Gympsum Board In False Ceiling With Beading And All Including Fixture Where Ever As Required Including Supply All Materials, Labours, T&P Etc. Required For Proper Completion Of Work. Reinforcement For R.C.C Work Including Straightening, Cutting Bending, Placing In Position And Binding All Complete (Cold Twisted Bars). Providing And Grouting With Convextra G.P.- 2 Of Standard Quality Approved By Engineer In - Charge Including Chipping Of Rcc And Including All Labors, T&P Etc. Complete. Installation & Running Of 5 Hp /7.5 Hp Elctric/Diesel Engine Motor Pump Set With Suction Of 5 Meter Depth & Delivery Pipe Up To The Distance Of 70 Meter In Near By Pit Including Cost Of All Hire Charges Of Motor Pump Set, Operator And Fuel Etc. Complete As Pr Direction Of Engineer In Charge. Cartage Of Grass/Malwa By Tractor Trally Upto A Distance Of 1 Km From Periphery Of Area Cleared, Including Cost Of All Labour, T&P Etc. Such As Loading Unloading & Cartage, Tractor Trally, Driver, Fuel Required For Proper Comlplletion Of Work. Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up To Floor Five Level Excluding Dismantling & Relaying Of Old G.I Pipe With Supply And Fixing Of Approved G.I Fitting As Per Required For The Following Base,Including Threading Of Pipe It Required,Including Cutting And Making Good Wall. 15 Mm To 20 Mm Dia. Dismantling & Relaying Of Old G.I Pipe With Supply And Fixing Of Approved G.I Fitting As Per Required For The Following Base,Including Threading Of Pipe It Required,Including Cutting And Making Good Wall. 40 Mm To 80 Mm Dia. Providing And Fixing Bright Finished Brass/Aluminium Hanging Type Floor Door Stopper With Necessary Screws Of Approved Brand , Etc. Complete. Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For All Type Of Work Upto 52 Mts Floor As Per Specification. Providing And Fixing 110X25 Mm Outer Dia. Pvc Saddle Or 110Mm Outer Dia Pvc Including Rubber Ring. Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete For Semi Regid Or Flexibel Upto 40 Mm Dia. Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately).Sal Wood Or Teak Wood(As Per Direction Of Engineer In Charge). Providing And Fixing Partition Upto Ceiling Height Consisting Of G.I. Frame And Required Board Including Providing And Fixing Of Frame Work Made Of Special Section Power Pressed/ Roll Form G.I. Sheet With Zinc Coating Of 120 Gms/Sqm(Both Side Inclusive), Consisting Of Floor And Ceiling Channel 50Mm Wide Having Equal Flanges Of 32 Mm And 0.50 Mm Thick, Fixed To The Floor And Fixed To The Studs Using Metal To Metal Flat Head Screws, Including Jointing And Finishing To A Flush Finish With Recommended Jointing Compound, Jointing Tape, Angle Beads At Corner (25 Mm X 25 Mm X 0.5 Mm), Joint Finisher And Two Coats Of Primer Suitable For Board As Per ManufactureS Specification And Direction Of Engineer In Charge All Complete. As Per Specification Of Dsr. Providing And Fixing 40 Mm Thickacid And/Or Alkali Resistant Tiles Of Approved Make And Colour Using Acid And/Or Alkali Resisting Mortar Bedding, And Joints Filled With Acid And/Or Alkali Resisting Cement Also Includs The Cost Of 10 Mm Thick Acid Proof Base/Lining As Per Is : 4457, Complete As Per The Direction Of Engineer-In- Charge.In Dado/Skirting On 12 Mm Thick Mortar 1:4 (1 Acid Proof Cement : 4 Coarse Sand) Acid And Alkali Resistant Tile. Supply Of 100 Mm Long 15 Mm G.I. Nozzle Including Cutting Holes In Rcc Slab, Column,Floor And Beam Including Its Fixing With Cement Mortar Including All Labour, T&P And Material Etc Complete As Per Direction Of Engineer-In-Charge. Pressure Grouting Of Crackes Honey Comb In Concrete Surface Expansion Joints Or Where Ever Required With Cement Grout Of Ratio One Part Of Cement, Four Parts Of Water And 3% Water Proofing Cicco No.3 Compound (Liquids) With The Help Of Grout Pump Of Appropriate Pressure Excluding Cost Of Fixing G.I. Nozzles Complete. As Per Engineer-In- Charge . Epoxy Adhesive Providing And Fixing Aluminum U Beading Of Required Size To Pre-Laminated/ Flush Door Shutter, Including Fixing Etc. Complete As Per Direction Of Engineer-In-Charge. Kg 435.10 Finishing With Epoxy Paint (Two Or More Coats) At All Locations Prepared And Applied As Per ManufacturerS Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete. On Concrete Work 12 Mm Thick Marine Plywood Conforming To Is: 710 Providing And Fixing 10 Mm Thick Acid And/Or Alkali Resistant Tiles Of Approved Make And Colour Using Acid And/Or Alkali Resisting Mortar Bedding, And Joints Filled With Acid And/Or Alkali Resisting Cement As Per , Complete As Per The Direction Of Engineer-In- Charge In Dado/Skirting On 12 Mm Thick Mortar 1:4 (1 Acid Proof Cement : 4 Coarse Sand) Acid And Alkali Resistant Tile Sqm 1607.70 Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete Size Of Tile 600X600 Mm Sqm Providing And Fixing G.I. Union In Existing G.I. Union 50 Mm Nominal Bore Each Providing And Fixing G.I. Union In Existingg.I. Union 25 Mm Nominal Bore Each Providing And Fixing White Vitreous China Pedestal Type (European Type/ Wash Down Type) Water Closet Pan. Each 2276.95 Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In - Charge. Each 297.55 12.5 Mm Thick Fully Perforated Gypsum Board Tile Made From Plasterboard Having Glass Fibre Conforming To Is: 2095 Part I, Of Size 595X595 Mm, Having Perforation Of 9.7X9.7 Mm At 19.4 Mm C/C With Center Borders Of 48 Mm And The Side Borders Of 30 Mm, Backed With Non Woven Tissue On The Back Side, Having An Nrc (Noise Reduction Coefficient) Of 0.79, With 50 Mm Resin Bonded Glass Wool Backing. Providing And Fixing Kitchen Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P. Brass Waste Complete, Including Painting The Fittings And Brackets, Cutting And Making Good The Walls Wherever Required: White Glazed Fire Clay Kitchen Sink Of Size 600X450X 250 Mm Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than Providing And Fixing Ptmt, Push Cock Of Approved Quality And Colour. 15 Mm Nominal Bore, 98 Mm Long, Weighing Not Less Than 75 Gms Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Granite Of Any Colour And Shade 8.2.2.2 Area Of Slab Over Providing And Fixing Plastic Seat Cover With Lid For Pedestal Type W.C.Pan Complete : White Plastic Seat With Lid Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings/ Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Bend 87.5° 110 Mm Bend Neat Cement Punning Fencing With Angle Iron Post Placed At Required Distance Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post On One Side Only And Provided With Horizontal Lines And Two Diagonals Interwoven With Horizontal Wires, Of Barbed Wire Weighing 9.38 Kg Per 100 M (Minimum), Between The Two Posts Fitted And Fixed With G.I. Staples, Turn Buckles Etc. Complete. (Cost Of Posts, Struts, Earth Work And Concrete Work To Be Paid For Separately). Payment To Be Made Per Metre Cost Of Total Length Of Barbed Wire Used. 16.18.1 With G.I. Barbed Wire Metre Providing And Fixing G.I. Union In Existingg.I. Union 15 Mm Nominal Bore Each Dismantaling By Electrical Hilti Including Cost Of Gst 18% Pr 1100069168 Rfq 6000011061
Contract Date: Ref. Documents Contract Value : 44.22 Lakh
Government Departments No of Bidders 5
Uttar Pradesh View Result →
15.
Defence #11206901 AOC
Tender For Provision Of Work Services For Sdr Facility In Abr Lab At 9Brd Afs Pune Under Ge Af Lohegaon - Taking down the existing surface batten type point wiring of aluminium/Copper for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. 2 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 3 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board )ISI Marked (IS:14772) for housing switches / sockets all a specified and directed 4 (a) One Fan point/ light point controlled by one switch. 5 (b) One 3 pin socket 5 A on same board. 6 (c) One 3 pin socket 5 A on independent board. 7 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board)ISI marked (IS 14782) for housingone 15 A Switch / socketsall a specified and directed 8 M/L for sub main wiring with two runs of single core 4.0 Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor1100 V grade with colour code and one run of 4 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cablefor continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified.(Note:- Two runs of 4 Sqmm copper cable & one run of 4 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length) 9 M/L for sub main wiring with two runs of single core 6.0Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in& including casing & caping all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 6 sqmm copper cable including PVC casing & caping shall be measured & paid as one length ) 10 Supply and fix switch piano flush type 5 Amp one way, ISI Marked 11 Supply and fix Socket out let 2in 1, 5 pin 5 Amp ISI Marked 12 Supply and fix switch socket combination 5 / 16 A, 5 in 1, flush type,ISI Marked 13 S/F Fan Regulator electronic step type 100 W,ISI Marked complete as directed 14 Supply and fix ceiling rose surface type bakelite / PVCthree terminal 65 x 50mm. ISI Marked 15 Taking down existing VTPN DB grouted in wall and S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 16 Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge. 17 Supply and fix MCB SPN B Curve 240 V, 32 Amps. complete all as directed at site. 18 Supply and fix MCB SP B Curve 240 V ,6 to 32 Amps complete all as directed at site. 19 M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plateNo. 3 of SSR Part I of 1991 & testing complete including 15mm dialight grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GIwatering pipe etc. 20 Supply and fixing in replacement of double pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed 21 S&F of CEE Panel mounted receptacles 16 A, 3 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 22 S&F of CEE Panel mounted receptacles 16 A, 5 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 23 S&F of CEE plug 16 A, 3 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 24 S&F of CEE plug 16 A, 5 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 25 S&F of Sub main wiringwith 4 X 6 sqmm single core cable FRLSH PVCinsulated unsheathed of copper multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 6 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 6 Sqmm & 1 length of 6 sqmm cable and PVC casing caping will be measured as one length). 26 S&F of Sub main wiringwith 4 X 10 sqmm single core cable PVCinsulated unsheathed of copper FRLSH multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length). 27 Taking down carefuly copper strip of Size upto 32x6mm including pocelain/epoxy insulator, storing in safe custody for reuse and refixing the taken down copper strip as directed at site including supply and Fix of new epoxy insulator at a gap of 1 meter and brazing of copper strip with double nut and bolt with overlap of 3 cm complete all as directed by Engr-In-Charge. 28 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 6000K colour temperature with current electronic connections as directed. 29 Supply and fix MCB TPN 415 V, 32 Amps 10 KA C Curve in DB complete all as directed at site. 30 Supply and fix MCB TPN 415 V, 40 to 100 Amps 10 KA C Curve in DB complete all as directed at site. 31 M&L for making hole in Brick masonary / Stone masonary wall of any thickness and height of round shape and suitable for exhaust fan of 380mm dia and making good disturbed wall and painting distubed area as original complete all as directed. 32 Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 380 mm sweep with, blades, and frame and louver complete all as specified and directed. 33 1. Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2TR having dual rotor inverter compressor, 100% copper IDU and ODU, installation kit with extra copper piping, connection electric cord, drain water pipe as per site requirement and incl MS Stand for outdoor unit fixng and core cutting in stone masonary wall if required for passing of refrigerant piping and cables etc and making good disturbed surfaces matching to existingcomplete all as specified and directed by Engr-In-Charge 34 Supply and fixing of voltage stabilizer for automatic operationsingle phase naturally air cooled indoor typefor input variationbetween 170V to 280V with outputVoltage 230v with accuracy +/-2.5% and of capacity 5 KVA completeall as directed. 35 Supply and laying HDPE DWC pipe 135 mm inner dia SN8 incl coupler on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. 36 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 300 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 37 S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 38 Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded copper conductor of size 35 Sqmm 3.5 Core laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix on wall etc all as specified and directed. 39 Supply install, test and commissioning of Powder coated LTpanel cubical Indoor type floor standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomerand outgoing feeders .The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhave bottom frame & dimension as required for panel & stand shall be made out of equal angle iron of size 50mm x 50mm x 6mm height 600mm. A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 tank process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including provision of heat shrink sleeve on each cable core within panel, lugs, nut bolts, washers etc complete all as specified and 40 a) Copper bus bar 500 Amps for 4 pole-01 SETb) MCCB FP 320 Amps415 Volt 50 KA,Ics =100% Icu WITH thermal and magnetic setting type - 1 Nosc) MCCB FP 100 Amps - 415 Volt 16 KA,Ics =100% Icu- 5 Nos f) RYB Indicators - 1 Set and g)Digital 3 Phase Amp Meter and Voltmeter with selector switch - 1 SetNote - (i) The lay out drawing of the panel shall be got approved by the contractor before panel fabrication. 41 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 25 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 42 Supply and fix Voltage stablizer for automatic operation, three phase , naturally oil cooled, inddoor type anddesigned for input variation between 300V to 480 V with accuracy + 2.5 % , IP55 Protection, 50 Hz, Unbalance type, copper wounded, matallic body duly powder coated, liftinghooks, digital display, relay controlled for smooth and silent operation with first filling of transformer oil upto specified level , with zero distortion waveform, sesitivity +/- 1%, overall Efficiency more than 95 % digital multifunction meterand speed of correction 8 volts per second and of capacity 30 KVA complete all as specified and directedNote: (a) Stablizer shall be free from hunting during automatic operation and No load losses shall not be more than 5% of rated output current.(b) Protection: (i) Overload short circuit protection at input end by MCCB 4 pole of suitable size as per recommendation of OEM - 01 Nos (ii) High / low voltage cutoff(iii) By pass arrangement - providing 01 No 4 pole on load changeover switch of suitable rating (iv) single phase sequence change protection.(c) Acceptance Test :- Testing of servo voltage stabilizer should be carried out as per BIS 9815 (Part-I) in OEM factory in the presence of rep of Accepting Officer and contractor/his rep. Contractor shall give 45 days in advance intimation with respect of date of testing. The following testing shall be carried out:(i) Physical Examination (ii) Insulation resistance (iii) High voltage test (iv) Leakage current test (v) Output voltage (vi) No load current (vii) Measurement of No load loss induced voltage testNote : Before make and specification approval type test report of OEM as per BIS 9815 Part - I should be produced by contractor for the specified capacity / next higher capacity of any voltage range from Govt Lab / NABL accredited lab. 43 Supply, installation,Boring, erection, testing and commissioningof Copper bonded(150 micron) MS solid rod electrode of dia 17.2 mm and 6 mtr long with high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm-m. Earthing Electrode shall bemade by embedding copper bonded MS Rod electrode in 100mm dia macronite conductive concrete made by mixing high purity conductive granularmixed with cement in the ratio2:1 (2 part of high purity electriclly conductive granular and 1 part cement and one litre of water per kg of mix ). The earthing electrode shall be augured inbore hole of dia not less than 100mm and6 Mtr depth. The conductive material shall confirm to BIS: 3043-2018. The rod shall be embedded in conductive concrete at factory with concrete having resistivity 0.040 Ohm-m. The top edge of the electrode shall comprise of plate provided with 04 holes for connections of the earthing strip,including brass nut bolts for connections of the strip the copper strip shall be duly brazed/welded with connection terminal of earthing rod, including FRP square chamber cover 300mm x 300mm x 250mm with top cover complete all as specified.All the material such as copperbonded MS rod and concrete mix shall be Ph nuetral, chemicaly inert and non corrosive complete all as specified and directed by Engr-In-Charge.i) The contractor shall submit type test report issued by the CPRI for high purity, electrically conductive earthings , confirms to rated short time withstand current20 KA per sec. ii) The factory made electrode shall be tested at factory and test report shall be submitted.iii) Factory testing of individual earthing shall be carried out in presence of rep of accepting officer and report shall be submitted.iv) The contractor shall obtain make approval for high purity electrically conductive granular duly by submitting certificates conforming to resistivity is 0.001 ohms by granular manufacturer.v) On installation of earthings at site, 04 to 05 Nos earthings shall be connected in grid to achieve less then 1 ohm resistance of grid, If desired resistance is not achived the contractor shall redo the same without any extra cost. vi) The contractor shall submit certificate issued by OEM of earthing electrode starting that The desired maintenance free earthing resistance less than 1 ohm. The year will be maintained for not less than 25 years. 44 M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.Note:-(i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 45 M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mmby means of bolts, nuts, checknuts & washers of copper and connecting to test point, providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs,including copper earth strip 20 x 3 mmwith GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified.Note-- (i) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3ohm with single earthing, Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 46 S&F in repair of test point made out of gun metal or phosphorous bronze of size 75x50x5mm duly mounted on epoxy insulator 02 Nos.Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal block cover box made out of M.S sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer. 47 S & F copper earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc.and connecting with earthing test point oras required complete all as directed. Note: Earth work required shall be deemed to be included in quoted rate, nothing extra shall be paid on this account. 48 Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole etc. 49 Soft/loose soil 50 Hard/dense soil 51 Soft/disintegrated rock 52 Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil. 53 Removing the surplus soil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level. 54 M&L for Cutting the existing road precisely for laying of cable crossing pipe and making good the distubed surface of road as per original after laying of pipe and removal of debries complete all as directed.Note: The cost of making good is deemed to beincluded in quoted rate. 55 Supply and fixof MCCB FP 63 AmpsFixed type with breaking capacity16 KA with Sheet metal enclosure of 2 mm thick CRCA sheet single door with provision opening for incomming and outgoing cable/ submain including connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
Contract Date: Feb 04, 2026 Contract Value : 35.23 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
16.
Defence #11200251 Technical Bid
Tender For Provision Of Certain Sanctioned Works Under Ge South Bathinda At Bathinda Mil Stn.- 1 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out And Getting Out In Soft / Loose Soil Complete All As Specified & Directed. 2 Removing Excavated Material Exc 1.50 Km N Exc. 5 Km And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And As Directed. 3 Excavation In Trenches Not Exceeding 1.5 Meter Wide And Not Exceeding 1.5 Meter Depth For Foundation Etc Or For Shafts , Wells, Cesspits, Manholes , Septic Tank, For Laying Of Cables , Laying Of Pipes Not Exceeding 10 Sqm On Plan And Not Exc 1.5 Meter Depth And Getting Out In Soft/Loose Soil Etc Complete All As Specified And As Directed By Engineer-In- Charge. 4 Material And Labour For Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 6 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 7 Material And Labour For Rcc M-25 (Design Mix) Using 20 Mm Graded Stone Aggregates As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 M Span And The Like Etc Complete All As Specified And As Directed By Engineer-In-Charge. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 8 Material And Labour For Rcc M-25 (Design Mix) Using 20Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors,Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed By Engineer-In-Charge.Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 9 Material And Labour For Formwork Of Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 10 Material And Labour For Formwork In Square,Reactangular Or Polygonal On Rough Finished Surface Of Concrete To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions Complete All As Specified And As Directed By Engineer-In-Charge. 11 Material And Labour For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc. On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 12 Material And Labour For Formwork To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slabs, Landings And Similar Work Not Exceeding 200 Mm Thick (Horizontal Or Sloping) On Rough Finished Flat Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 13 Material And Labour For Formwork To Edges Of Concrete Flats, Treads, Breaks In Floors,Window Cills, Concrete Rail Ings, Openings In Concrete Walls, Floor And Roofs Not Exceeding 20Cm Wide And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exceeding 10 Cm But Not Exceeding 20Cm Wide On Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 14 Material And Labour For Mild Steel Tmt Bars 10Mm Dia And Over Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 15 Material And Labour For Mild Steel Tmt Bars 6Mm To 8Mm Dia Cut To Length Bent To Shape, Required Including Cranking, Bending Spirally For Hoping For Columns, Hooking Ends And Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Including Making Of Rungs, Handles Etc Complete All As Specified And As Directed By Engineer-In-Charge. (Note : Weight Of Binding Wire Shall Not Be Considered For Measurement And Payment Purpose.) 16 Demolition Of Brick Work Or Stone / Boulder Masonry, Built In Cement Mortar Or Cement Lime Mortar Including All Quoins, Arches, Pillars, Etc, In Any Description Complete All As Specified And As Directed By Engineer-In-Charge. 17 Material And Labour For Brick Work With Sub Class ‘B’ Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 18 Material And Labour For Brick Work With Fly Ash Bricks Straight Or Curved On Plan Exceeding 6.0M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And As Directed By Engineer-In-Charge. 19 Material And Labour Brick Work With Sub Class ‘B’ Old Size Burnt Clay Bricks Straight Or Curved On Plan Exceeding 6 Metre Mean Radius Built In Cement Mortar 1:6, Complete All As Specified And As Directed By Engineer-In-Charge . 20 Material And Labour For Brick Work With Fly Ash Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Walls Built In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In-Charge. 21 Demolition Of Cement Concrete (Unreinforced) In Ground Floor And Paving Not Exceeding 15Cm Thickness Below Or Above Ground Level Of Any Description And In Any Position Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge 22 Material & Labour For Cement Concrete 1:3:6 Type C-2 Using 40 Mm Graded Stone Aggregate For Foundations, Fillings & Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 23 Material And Labour For Cement Concrete (1:5:10), Type E-2 Using 40 Mm Graded Stone Aggregate As In Filling Of Sunken Floors Complete All As Specified And As Directed By Engineer-In-Charge. 24 Demolition Of Concrete Of Any Description And In Any Position Not Otherwise Specifically Provided Complete All As Specified And Directed. 25 Material And Labour For Waterproofing Treatment To Sunken Floor Using Acrylic Based Multipurpose Polymer. The Treatment Shall Be Carried Out As Per Manufactures Specification. The Treatment Shall Be Include Of The Following Elements Also: 1. Surface Preparation Of Substrate By Removing All Traces Of Contaminates, Loose And Friable Particles, Cement Laitance Oils And Grease, Water Repellent Coatings Etc2. Injection Grouting Using Cementitious Grout If Required. The Payment For Injection Grouting Shall Be Made Separately Etc3. Repair To The Substrate, Filling Of Blow Holes/Voids And Surface Leveling Using Appropriate Products Specified By The Manufacture.4. All Intersections Of Horizontal And Vertical Surface Should Be Profiled With A Mortar Fillet Of Minimum 25Mm X 25Mm.5. The Moisture Content Of The Substrate Shall Be Checked Before Application Of First Coat At Water Proof Coating At The Rate Of 200 G/M2 Followed Brush Topping At 450G/M2 Per Mm. The Second Coat Shall Be Reinforced With Glass Fabric Between The First And Second Coat.6. The Treatment Shall Be Protected By Application Of Polymer Modified Cement Mortar Of Thickness 10Mm Applied At The Rate Of 50G Per Mm.7. Tech Specification : Tensile Adhesion Strength 0.5N/Sqmm (As Bonding Slurry). 26 Material And Labour For Aerated Autoclaved Concrete (Aac) Blocks Work According To Indian Standard Specification Is:2185(Part-3)-1984 And Latest Revision Built In Cement And Sand Mortar 1:6 With Aerated Autoclaved Concrete (Aac) Blocks Straight Or Curver On Plan Exceeding 6Mtr Mean Radius As In Sunken Floor Complete All As Specified And And As Directed By Engineer-In-Charge. 27 Supply Only Integral Water Proofing Compound. 28 Removing Excavated Material As In All Kind Of Soils Not Exceeding 50M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed By Engineer-In- Charge. 29 Returning Filling In Any Type Of Soil, Including Spreading, Levelling,Watering And Well Ramming In Layer Not Exceeding 25 Cm In Each Layer, Complete All As Specified And As Directed By Engineer-In- Charge. 30 Material And Labour For Sand Filling Under Floor Or In Foundation Including Spreading Levelling, Watering And Well Ramming In Layers Not Exc 25 Cmetc Complete All As Specified And As Directed By Engineer-In- Charge. Note: Sand Shall Be Approved By Ge. 31 Material And Labour For Hard Core Using Broken Stone Aggregate Of Gauge Not Exc. 63Mm, Deposited Spread And Leveled In Layers Not Exc. 150 Mm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In- Charge. 32 Material And Labour For 75 Mm Thick Cement Concrete 1:4:8 , Type D-2 Using 40 Mm Graded Stone Aggregate As In Sub Base Of Floor. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 33 Material And Labour For Rendering 10 Mm Thick In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces Of Walls And Finishing The Surface Even & Fair Faces Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 34 Material And Labour For Rendering 5 Mm Thick In Cement Mortar In (1:3) On Ceiling And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 35 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 36 Material And Labour For 15Mm Thick Rendering In Cement Mortar 1:4 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Fair & Even Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. Note :- Liquid Water Proofing Compound Shall Be Measured And Paid Separately. 37 Supply And Fixing Chicken Wire Mesh ( Murga Jali ) In Cement Plaster Or Over Joints Of R.C.C And Brickwork Or As Per Site Requirement Of 24 Gauge & 12 Mm Mesh And 300 Mm Width For Construction Joints And Chasing In Brick Work For Electrical Conduits Or Water Supply Pipes And Pegs/Nails With Nailing Machine As Required Before Rendering / Plastering Etc. Complete As Per Site Requirement Complete All As Specified And As Directed By Engineer-In- Charge.Note: Rendering / Plastering Shall Be Measured And Paid Seperately Under Serial Item No. 5.00 Of ScheduleA Boq Here-In- Before. Nothing Shall Be Paid Extra On Account Of Rendering / Plastering In This Item. 38 Material And Labour For Applying Acrylic Wall Care Putty On Internal Surfaces And External Surfaces Of Walls/Ceilings/Soffits (Thickness Vary From 1.5 To 2.5 Mm As Required For Desired Smoothness And Leveling Of Surfaces In Two Or More Layers) By Using Ready Made Acrylic Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc Complete All As Specified And Directed By Engineer-In- Charge.Make Of Acrylic Wall Care Putty : As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After.Notes : (I) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. (Ii)The Make Of Acrylic Wall Care Putty Shall Be As Per The Recommendation Of Manufacturer Of Paint. 39 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 40 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying 01 Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Existing Shade @ 10 Sqm/Litre/1 Coat By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits ( Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc, Over Including A Coat Of Exterior Wall Primer @ 10 Sqm/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Including Removing The Vegetation Of Any Type And Description The Making The Surface Good Complete All As Specified And Directed. 41 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Interior Acrylic Emulsion Paint (Light Shade As Approved By Ge ) @ 10.00 Sq.M/ Litre / 2.00 Coats By Using Roller/Brush To Wall Surfaces Over With And Including One Coat Of Interior Acrylic Emulsion Primer @ 10.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Interior Acrylic Emulsion By Using The Brands Of Interior Acrylic Emulsion Paint And Interior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 42 M&L For Preparing Existing Treated Surfaces Of Ceiling Including Cornices And Applying Two Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And As Directed By Engineer-In-Charge. 43 Material And Labour For Preparation Of New Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 44 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Interior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Including A Coat Of Exterior Wall Primer @ 11 Sq.M/Litre/1 Coat As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed. 45 Material And Labour For Preparation Of Old Surfaces And Applying 02 Coats Of Exterior Acrylic Emulsion Paint ( Shade As Approved By Ge) With Highlighter Of Any Approved Shade, @ 5.00 Sq.M / Litre / 2.00 Coats By Using Roller To External Walls / Rcc Surfaces / Soffits Of Chajjas / Roof Projections / Cantilevers / Balcony Etc. Surfaces Over With And Including One Coat Of Exterior Acrylic Emulsion Primer @ 11.00 Sq.M / Litre / 1.00 Coat As Recommended For Under Coat By Manufacturer Of Exterior Acrylic Emulsion By Using The Brands Of Exterior Acrylic Emulsion Paint And Exterior Acrylic Emulsion Primer As Descriped In List Of Makes/Manufacturers Under Appendix B Here-In-After Complete All As Specified And Directed By Engineer-In- Charge. 46 Material And Labour For Complete Removal Of Existing Treatment Of Any Type / Description From Wall / Rcc Surfaces / Ceiling / Chajjas / Roof Projections Etc With Mechanical Means / Grinder And Applying One Coat Of Exterior Emulsion Paint (Light Shade) With Highlighter Of Any Approved Shade @ 5 Sqm/Litre/2 Coats By Using Roller To External Walls / Rcc Surfaces/Soffits Of Chajjas / Roof Projections /Cantilevers/ Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer @ 11 Sqm/Litre/1 Coat Over Acrylic Thick Wall Care Putty On External Surfaces Of Walls / Ceiling / Soffits (Thickness Vary From 1.5 To 2.5Mm As Required For Desired Smoothness And Levelling Of Surfaces In Two Or More Layers) By Using Ready Made Wall Care Putty Including Sand Papering After Filling The Putty To Make Surface Smooth And Ready For Receiving Painting Etc As Recommended For Under Coat By Manufacturer Of Exterior Emulsion By Using Following Brands Of Emulsion And Primer Complete All As Specified And Directed.Note For Item No 5 To 8 :- (A) The Prepared Surface After Wall Putty, The Contractor Will Inform To The Ge As Well As To The Engineer-In-Charge For Site Inspection Before Applying Further Finishes. Please Note That The Further Finishes Work Will Start Only After Approval Of The Prepared Surface From The Ge As Well As To The Engineer-In-Charge Through Site Order. 47 Material And Labour For For Preparing New Plastered Surfaces Of Ceilings And Applying Three Coats Of White Wash By Making The Lime Slaked At Site And Shall Be Mixed And Stirred With About Five Liters Of Water For 1 Kg Of Unslaked Lime To Make A Thin Cream. This Shall Be Allowed To Stand For A Period Of 24 Hours And Shall Then Be Screened Through Clean Coarse Cloth. 1 Kg Of Gum Dissolved In Hot Water Shall Be Added To Every One Cubic Meter Of Lime Cream. About 1.3 Kg Of Sodium Chloride Dissolved In Hot Water Shall Also Be Added For Every 10 Kg Of Lime For Making The Coating Hard And Rub-Resistant. Small Quantity Of Ultramarine Blue (Upto 3 Gm Per Kg Of Lime) Shall Also Be Added To The Last Two Coats Of White Wash Solution And The Whole Solution Shall Be Stirred Thoroughly Before Use Complete All As Specified And Directed By Engineer-In- Charge. 48 Material And Labour For Applying Three Coats Of White Wash On Newly Plastered Or Unplastered Ceiling Surfaces Including Preparation Of Surfaces, Complete All As Specified And Directed 49 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frames) Area Not Exc 1.5 Sqm Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 50 Taking Down Chowkats Or Frames With Shutters (Without Taking Off Shutters From The Frame) Exc 1.5 Sqm But Not Exc 4 Sqm Each Each As Doors, Windows And Ventilators And Removal From Site Complete All As Specified And Directed. 51 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat Of Size 45Mm X 70 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 52 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Door Frame / Chowkhat With Double Rebate Of Size 65Mm X 125 Mm Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Fabricated With Miter Joints After Applying Pvc Solvant Cement And Screwed With Full Body Threaded Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg /Cum And Screw Withdrawl Strength Of 2200 N (Face ) & 1100 N (Edge) Minimum Compressive Strength Of 58 N /Sqmm Modulus Of Elasticity 900 N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retaident And Fixed In Position With And Including Ms Hold Fast Lugs / Ss Dash Fastner Of Required Dia And Length With And Including Supply And Fixing (03 Nos Per Frame ) 100 Mm Long Ss Butt Hinges Complete All As Specified And As Directed By Engineer-In- Charge. 53 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Plain Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 54 Supply & Fixing Factory Made Single Extruded Wpc ( Wood Polymer Composite ) Solid Decorative Flush Door Shutter Of 30 Mm Thick , Size Comprising Of Virgin Polymer Of K Value 58-60 (Suspension Grade ), Calcium Carbonate And Nautral Fibers ( Wood Powder / Rice Husk / Wheat Husk ) And Non Toxic Additives (Maximum Toxcity Index Of 12 For 100 Gms ) Having Minimum Density Of 650 Kg /Cum And Screw Withdrawl Strength Of 1800 N (Face ) & 900 N (Edge) Minimum Compressive Strength Of 50 N /Sqmm Modulus Of Elasticity 850N/Sqmm And Resisitence To Spread Of Flame Of Class A Category With Property Of Being Termite / Borer Proof , Water Moisture Proof And Fire Retardant And With And Including Supply & Fixing Of 02 Nos (Per Leaf) Ss 150Mm Long Tower Bolt, Supply & Fixing Of 02 Nos (Per Door) Ss 300Mm Long Sliding Bolt With And Including Supply & Fixing Of 02 Nos (Per Leaf) Stainless Steel 150Mm Long Handle Complete All Specified And Directed By Engineer -In-Charge. 55 Supply & Fixing Factory Made 30Mm Thick Solid Wpc ( Wood Polymer Composite ) Wiremesh Door Shutter Of Required Size Comprising Of Virgin Pvc Resin Of K Value 57-60 ( Suspension Rade ), Calcium Carbonate And Natural Fibers ( Wood Powders/ Rice Husk/ Wheat Husk ) And Non Toxic Additives, Made From Extrusion Process Wpc Foam Sheet Single Extruded ( Inner ) With Having Minimum Density Not Less Than 650 Kg/Cum , Having Good Screw Holding Capacity ( Screw Withdrawal Strength Of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Of 50 N/Mm2, Modulus Of Elasticity 850N/Mm2 And Resistance Of Spread Of Flame Of Class A Category With Property Of Being Termite/ Borer Free.Water/ Moisture Proof And Fire Retardant. Pvc Foil Of Minimum 14 Microns Thick Of Approved Design Pasted On Both Faces Of Shutter For Fixing Mosquito Mesh And Xtn Aluminium Mesh Together On Panel Area Of Door Except Stiles And Rails To Be Panelled With And Including Mesh With Self Tapping Round Headed Scresws At Required Distance, Screws And Edges Covered With Feathered Pvc Edge Beading All Around Of Mesh And Fixing Stainless Steel Butt Hinges Of Required Size With Necessary Full Body Threaded Star Headed Counter Sunk Ss Screws With And Including 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01 No. Of Helical Door Spring Of 300 Mm Length Complete All As Specified And As Directed By Engineer-In-Charge. Note: 1. Material Test Certificate Of All The Items And Authentication Should Be Compulsory Provided By The Manufacturing Company 2. The Rate Of 03 Nos Door Stainless Steel Butt Hings 100Mm Long With Stainlessd Steel Screws For Each , 02 Nos Stainless Steel Barrel Tower Bolts Of Extrude Section, 150Mm Long (Isi Marked), 2 Nos Stainles Steel Handles, 125 Mm Long, (Isi Marked) , 01No. Of Helical Door Spring Of 300 Mm Length Is Inclusive In This Item And Nothing Shall Be Paid Extra On This Item..3. The Rate Of Mosquito Mesh And Xtn Aluminium Mesh Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 56 Supply And Fixing Factory Made Upvc White Colour Casement (Openable) Window (Area Exceeding 1.00 Sqm But Not Exceeding 2.00 Sqm Each) Made Of Extruded Profiles With Wall Thickness Of 2.3Mm ( + – 0.2Mm). Window Profile With Hollow Section With Multi Chamber, Frame (60Mm X 58Mm), Sash (60Mm X 73Mm), T Profile (One Vertical Length In Between Two Shutters) (60Mm X 74Mm), Glazing Bead (35Mm X 20Mm) Will Be Mitered Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc., Making Arrangement For Fixing Of Hardware. Epdm Gasket 1.2 +– 0.2Mm Thick, Galvanized Steel Frame (28Mm X 21.5Mm), Sash (31Mm X 27.5Mm). T Profile (27Mm X 17Mm) To Be Inserted In Required Profile, Frame Will Be Fixed To The Wall With 8 Mm X 100Mm Long Fasteners. Hardware: [Casement Handle Made Of Zinc Alloyed (White Powder Coated), But Hinges OfZinc Alloyed (White Powder Coated), Transmission Gear Made Of Mild Steel With Multi Point Locking System] And 5Mm Thick Glazing With Selected Quality Glass.(Note: The Unit Rate Quoted By Contractor Excludes Cost Of Glass And Includes All Other Connected Accessories. Net Opening Will Be Measured For Payment Purpose.) 57 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-1 Using 20 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 58 Material And Labour For 75 Mm Thick Pcc 1:3:6 , Type C-2 Using 40 Mm Graded Stone Aggregate As In Plinth Protection, Finishing The Surface Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In- Charge. 59 Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete)Of Any Dia Set In Cement Laid In Trenches Incl All Fittings & Accessorises Complete All As Specified And As Directed By Engineer-In- Charge. 60 Supply & Fixing For 4 Mm Thick, Sheet Glass Ordinary Quality And Glazing With Oil Putty In Square Not Exceeding 0.5 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 61 Supply & Fixing 4.0 Mm Thick Figured Glass Pin Head Type And Glazing With Oil Putty In Square N.Exc 0.5 Sqm In Each Pane Complete All As Specified And Directed 62 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 63 Supply & Fixing 5.5 Mm Thick, Sheet Glass Ordinary Quality Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In- Charge. 64 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles, Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accourdingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles , Aluminium Butt Hinges, Aluminium Handles , Aluminium Tower Bolts , Aluminium Peg Stays & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (V)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill . 65 Supply & Fixing Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Stainless Steel Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 66 Supply & Fixing Galvanised Ms Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Tinned Tacks To Galvanised Ms Wire Staple Complete All As Specified And As Directed By Engineer-In-Charge. 67 Material And Labour For Providing And Laying Premium (1St Quality) Straight Edge,Stain Free, Glooss Finish, Square Marbonite Double Charged Vitrified Tiles Size In 600Mm X 600Mm X 9Mm To 10Mm Thick As In Floors Etc. Shade As Approved By Ge , Set And Jointed With Using Spacer And Approved High Polymer Modified, Grey Cement-Based Tile Adhesive Suitable For Fixing Medium Format Tile/Stone In Walls/Floor Conforms To Is 15477 : 2019 Type 2T “Adhesives For Use With Ceramic, Mosaic And Stone Tiles” Conforms To En 12004: 2017 And Is A Normal Cementitious Adhesives (C1) With Slip Resistance (T) Of Class C1 And Necessary Grouting As Per Manufacturer’S Instruction, Completed All As Specified And Directed By Engineer-In-Charge. 68 Supply And Fixing Anodised Aluminium Snap Grid Frame Work For False Ceiling 605Mm X 605 Mm Etc Complete All As Specified And As Directed By Engineer-In-Charge. 69 Supply And Fixing False Ceiling At All Heights With Grg (Glass Fibre With Reinforced Gypsum) False Ceiling Tiles Of Size 595 X 595 Mm Of Approved Tecture Design And Patterns Having Moisture Content Less Than 2% Humidity Resistance Of 99%, Nrc 0.50 To 0.75 As Per Is 8225:1987, Noncombustible As Per Bs 476 (Part 4)- 1970 And Light Reflectance Of 85%D (Minimum) To Be Laid In True Horizontal Level Suspended On Inter Locking Metal T-Grid Of Hot Dipped Galvanisezed Iron Section Of 0.33Mm Thick (Galvanized @ 120 Grams Per Sqm Including Both Sides) Comprising Of Main T Runners Of Size 15 X 32 Mm Of Length 3000 Mm, Cross-T Of Size 15 X 32Mm Of Length 1200Mm And Secondary Intermediate Cross T Of Size 15 X 32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600Mm, Suspended From Ceiling Using Galvanised Mild Steel Items (Galvanizing @ 80 Grams Per Sqm) I.E 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L Shape Level Adjuster Of Size 85 X 25 X 2Mm. Galvanized Iron Perimeter Wall Angle Of Size 24 X 24 X 0.40Mm Of Length 3000 Mm To Be Fixed On Periphery Wall I Partition With Help Of Plastic Rawl Plugs At 450 Tiles Fully Center To Center And 40Mm Long Dry Wall Wodd Screws. The Work Shall Be Carried Out As Per Specifications, Drawing And As Per Directions Of The Engineer-In-Charge. 70 Material And Labour Anodised Aluminium Frame For Doors, Windows, Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Omplete All As Specified And As Directed By Engineer-In-Charge. 71 Material And Labour For Providing And Fixing Aluminium Work With Polyester Powder Coated Aluminium ( Minimum Thickness Of Polyester Powder Coating 50 Micron For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/Appropriate Z Sections And Other Sections Of Approved Make Conformikng To Is:733 And Is :1285, Fixing With Dash Fasteners Of Required Dia And Size,Including Necessary Filling Up The Gaps At Junctions I.E At Top , Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth , Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Aluminium Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling , C.P. Brass/ Stainless Steel Screws, All Complete All As Specified And Directed By Engineer-In-Charge .Note :- (I) Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Physically Ascertained Through A Board Of Officers Convened By Ge And Payment Shall Be Made Only After Ascertaining The Actual Weight Of Aluminium At Site.(Ii) The Rate Of Material And Labour For Providing The Epdm Rubber, Neoprene Gasket , C.P. Brass / Stainless Steel Screws Are Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) During Considering The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading , The Weight Of Epdm Rubber, Neoprene Gasket , C.P. Brass/ Stainless Steel Screws Shall Not Be Considered For Measurments And Payments. Only The Weight Of The Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading Shall Be Considered And Measurment And Payment Shall Be Made Accordingly.(Iv) During The Weight Of Aluminium Sections , Aluminium Cleat Angles & Aluminium Snap Beading ,The Weight Of Polyester Powder Coating 50 Micron Shall Not Be Considered For Weight But The Rate Of Material And Labour For Providing Polyester Powder Coating 50 Micron Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (V) Powder Coated Butt Hinges, Aluminium Handles, Aluminium Tower Bolts & Aluminium Peg Stays Shall Be Measured And Paid Seperately Under Respective Itmes Of ScheduleA Boq.(V) Glazing /Paneling And Wire Mesh Shall Be Measured And Paid Seperately. (Vi)The Board Shall Be Duly Countersigned By Ge Shall Enclosed With Final Bill 72 Material And Labour Anodised Aluminium Grill (Anodised Transparent Of Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer-In-Charge. 73 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 15Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 74 Taking Up Or Down Galvanised Steel Water Tubing (Gi Pipe) 20Mm Bore Including Fitting/Connection From Wall/Ceiling/Floor/Concealed Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 75 Supply And Fixing 16 Mm Bore Cpvc Pipe Sdr 11 With And Including Cpvc Sdr 11 Fittings And Fixed To Walls & Ceilings Or Laid In Floors, Complete Complete All As Specified And As Directed By Engineer-In-Charge 76 Supply And Fixing 20 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 77 Supply And Fixing 25 Mm Bore Cpvc Pipe Sdr 11And Plain Cpvc Sdr 11 Fitting With All Fitting And Fixed To Walls & Ceilings Or Laid In Floors, Including Taking Down Unservicable Existing Gi Tubing Of 20Mm Bore And Fittings Complete Complete All As Specified And As Directed By Engineer-In-Charge. 78 Material And Labour For Cutting Chases In Brick Wall , Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 Or Pcc 1:2:4 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Exc 10 Cm But Not Exc 20 Cm Girth Complete All As Specified And As Directed By Engineer-In- Charge.. 79 Supply And Fixing In Repair Brass Chromium Plated Wall Mixer For Mixing Hot & Cold Water Screwed Down, Screwed For 15Mm Bore Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 80 Supply And Fixing In Repair Bib Taps Cost Copper Alloy With Crutch Or Butterfly Handle , Screwed Down , Chromium Plated Screwed For Iron Pipe Or Brass Ferrul For 15Mm Bore Dia Pipe Complete All As Specified And Director. 81 Supply And Fixing In Reapir 15Mm Bore Bib Tap, Long Body, Fancy Type, Chromium Plated, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed By Engineer-In-Charge. 82 Supply And Fixing In Repair 15Mm Bore Stop Valves, Fancy Type, Chromium Plated With Long Shank And Cup (Concealed Type) Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed For Iron Pipe Or For Brass Ferrule Complete All As Specified & Directed By Engineer-In-Charge. 83 Supply And Fixing In Repair Angular Stop Cock With Wall Flange, Fency Type Chromium Plated Cast Copper Alloy Screwed Down, High Pressure, Screwed One Ends For 15Mm Bore Of Iron Pipe Or For Union And Fixed In Position Complete All As Specified & Directed By Engineer-In-Charge. 84 Supply And Fixing In Repair Vitreous China Wash Hand Basin, White, Flat Back, Size 450Mm X 300 Mm Including Cast Iron Cantilever Bracket With And Including 32 Mm Dia Brass Waste Coupling And With And Including Fixing Of Waste Fitting And Union Complete All As Specified And As Directed By Engineer-In-Charge. 85 Supply And Fixing In Repair Ptmt Mirror Cabinet Of Size 380Mm X 450Mm Best Quality Confirming Ot Sample Kept In GeS Office Complete All As Specified And Directed By Engineer-In-Charge. 86 Supply And Fixing In Replacement Sink With Drainage Board Made Of Stainless Steel 1 Mm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X460Mm Bowl Size 410Mm X330Mm X160Mm Complete All As Specified And As Directed By Engineer-In-Charge. 87 Supply & Fixing In Replacement Brass Cp Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed For Iron Pipe 15Mm Bore Complete All As Specified And As Directed By Engineer-In-Charge. 88 Supply And Fixing In Repair Stainless Steel Plate Rack Of Size 900Mm X 600Mm X 250Mm And Thickness Of Stainless Steel Strip Of 1Mm Fixed On Wall Etc. Complete All As Specified And Directed . 89 Material And Labour For Cutting Holes In Brick Walls Built In Cement Mortar (Not Exceeding Half Brick) For Inserting Hold Fast And Making Good Dismantled Portion In Cm 1:3 Or Cement Concrete 1 : 2 : 4 , Type B1 As Required , Depth Of Embedded Portion Exceeding Half Brick Walls And Not Exceeding One Brick Of Hold Fast Or Lugs Measured From The Face Of The Jamb Into Walls Complete All As Specified And As Directed By Engineer-In- Charge. 90 Material And Labour For In Repair Vitreous China Wash Down Water Closet Pan Wall Hanging Single Piece (With And Including Flushing Cistern Ewc) P Trap, With And Including White Coloured Closed Pattern Plastic Seat Cover, Hand Faucet , With And Including Mild Steel Chromium Plated Or Aluminised Hinging Device Complete All As Specified And As Directed By Engineer-In- Charge. 91 S & F In Repairs Cp Stainless Steel Grating (With Or Without Waste Hole), 125Mm Size, Fixed On Floor/Nahani Gully Trap Traps Etc Complete All As Specified And Directed. 92 S&F In Repair 25Mm Dia And 1Mm Thick Stainless Steel Drapery Rod Including With Bracket / Wall And Other Side Fancy Knobs At Both Ends As Approved By Engineer-In-Charge/Ge Including Taking Down Old Existing Rod/Pelmet With Accessories Complete All As Specified. 93 Supply And Fixing Cp Brass Fancy Type Corner Glass Shelf (25Cm/30Cm ) With Cp Brass Bracket & Railing Etc. Complete All As Specified And As Directed By Engineer-In- Charge. 94 Supply And Fixing In Repair Stainless Steel, Chromium Plated, Decorative Type, Soap Dish Holder Of Approximate Size 160Mm X 160Mm X 90 Mm Fixed To Wall With Rubber Plugs Complete All As Specified And As Directed By Engineer-In-Charge. 95 Supply & Fixing In Replacement Brass Chromium Plated Tubular Towel Rail 20Mm Dia D Type, 600Mm Long Between Flanges Fixed To Plug , Bracket With Chromium Plated Brass Screws Complete All As Specified And Directed By Engineer-In-Charge. 96 Supply And Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Pipes Single Socket 6 Kg/Sq Cm In Any Length With Stack Clamps Made Out Of 50Mm By 5 Mm Flat Iron And 16Mm Dia Round Iron Stays, Including Bolts And Nuts And Securing Ends Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge. Including Taking Down Old Ac Eaves Gutters And Rainwater Pipes ( Of Any Size And Pattern), Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 97 Supply & Fixing 110 Mm Bore Of Pipe Pvc (Swr) Type B Ring Fit Pipes Single Socket In Any Length With Stack Clamps As Shown In Btd Drg No. 916 Sheet 1/4 To 4/4 And Btd-917 Sheet Sheet 1/1 Of Stays To Wall At A Distance Of 100-120Mm Away From Walls Complete All As Specified And As Directed By Engineer-In- Charge Including Taking Down Old Ac Eaves Gutters And Rain Water Pipes ( Of Any Size And Pattern) Including All Fittings, Compete All As Specified And As Directed By Engineer - In-Charge. 98 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 100 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 99 Dismantling And Disconnecting Of Existing Ci Soil Vent Pipe 75 Mm Bore Fixed To Wall,Laid In Trenches Incl All Fittings & Accessories Complete All As Specified And Directed. 100 Supply And Fixing 110 Mm Bore, Pvc (Swr) Fittings Type -B Such As Bends, Tee, Shoe Etc; Fixed To Pvc Pipes, Compete All As Specified And As Directed By Engineer - In-Charge. 101 Supply & Fixing 110Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Laid In Trenches Or In Floors Complete All As Specified And As Directed By Engineer-In- Charge. 102 S&F 110 Mm Bore Of Pvc (Swr) Bends And Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 103 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Single Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 104 S&F 75 Mm Bore Of Pipe Pvc (Swr) Pipes Type - B Double Socket In Any Length With Rubber Ring Joint Fixed To Walls With Ms Clamps Of F1 25X2Mm Complete All As Specified And Directe 105 S&F 75 Mm Bore Of Pvc (Swr) Bends & Tee, Type - B Of Any Radius / Shoe With Access Door Fixed To Pvc Pipes Complete All As Specified And Directed. 106 S&F In Repairs Pvc (Swr) Gully Trap Of Size 150 X 150 Mm, Square Or Round Mouthed, Type P Setting And Jointing With Solvent Cement Complete All As Specified And Directed. 107 Supply And Fixing In Repair Pvc (Swr) Type -B Floor Trap Any Type (Q, S, P), 110/75Mm Dia With Grating Including Jointing To Waste Pipe Fixed In Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate Complete All As Specified And Directed By Engineer-In- Charge. 108 Supply And Fixing In Replacement 10 Litres Capacity Pvc Valveless Syphonic Action Type Low Level Flushing Cistern White With Inlet, Ball Valve, Float, Handle Including Brackets And 32Mm Dia Pvc Flush Pipe Complete All As Specified And Directed By Engineer-In-Charge. 109 S&F In Repair Vitreous China Wash Basin, White, Oval Type , Size 450 Mm X 300 Mm Fixed On And Including Cast Iron Cantilever Bracket, 32 Mm Dia Brass Waste Coupling And Including Fixing Of Tap, Waste Fitting And Union Complete All As Specified And Directed. 110 Supply & Fixing In Repair Chromium Plated Square Shower Rose 200Mm X 200Mm Size, With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipe Or Union For 15Mm Bore Of Pipe Complete All As Specified And As Directed By Engineer-In-Charge. 111 Supply & Fixing In Repair Pvc Connections 15Mm Size With Brass Nuts Of Length 450Mm Complete All As Specified And As Directed By Engineer-In-Charge. 112 Supply & Fixing In Repair Pvc Waste Pipe With Socket Suitable For Connection To Waste Fittings Of 32/40Mm Dia, And Of Length Minimum 75 Cm Complete All As Specified And As Directed By Engineer-In-Charge. 113 Supply And Fixing In Replacement Three Layers 500 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 114 Supply And Fixing In Replacement Three Layers 1000 Litre Hdpe Water Storage Tanks Polyproof. White In Colour Rotational Moulded Polyethylene (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Supply And Fixing Of Suitable Size Inlet/Outlet Arrangement & Other Accessories Complete All As Specified And As Directed By Engineer-In-Charge. 115 Supply And Fixing In Repair Ball Valve High Pressure Of Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe Of Size 20 Mm Bore (Minimum Weight 20Mm-210 Gram) Complete All As Specified And As Directed By Engineer-In- Charge. 116 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 20Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 117 Supply & Fixing In Repair Gun Metal, Globe Or Gate Valve (Isi Marked), Brass Cast Copper Alloy, With Iron Wheel Head, Screwed Both Ends Suitable For 25Mm Bore Iron Pipes Complete All As Specified And As Directed By Engineer-In-Charge. 118 Supply And Fixing In Replacement Bevelled Edge Mirror Selected Quality 5Mm Thick Glass Mounted And Fixed To With Chromium Plated Brass Screws And Cup Washers, With And Including Pvc Frame Around Made Of Pvc Channel, Complete All As Specified And Directed By Engineer-In-Charge. 119 Supply And Fixing In Repairs Sheet Glass Shelf Assembly Consisting Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Bracket Guard And Railing 60Cm Long Complete All As Specified And As Directed By Engineer-In- Charge. 120 Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 121 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Permises Etc. Complete All As Specified And Directed By Engineer-In-Charge. 122 M&L For Pcc (1:2:4) Type B-1, Using 20 Mm Graded Stone Aggregate As In Floor Surface Finished Fair 30 Mm Thick Below Tiles Complete All As Specified And Directed. . 123 M & L Non-Skid Coloured Ceramic Tiles 7 To 8 Mm Thick (Square/ Rectangular) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over & Including 15Mm Thick Screed In Cm 1:6 Complete All As Specified And Directed. 124 Material And Labour 25Mm Thick Cement Concrete Type B-1, 1:2:4 (12.5 Mm Graded Stone Aggregate) As Floors, Sub-Floors Etc And Finishing Surfaces Of Concrete Topping As Even & Fair Or Even & Rough To Receive The Topping Layer Complete All As Specified And Directed By Engineer-In-Charge. 125 Material And Labour For Double Charge Vitrified Ceramic Tiles ,Stain Free, Having Size Not Less Than 600X300Mm And 8 Mm Thick, Premium (1St Quality) Straight Edge, Colour As Approved By Ge , As In Vertical Surfaces Such As Skirting , Set And Jointed In Neat Cement Slurry And Laid Over And Including 10 Mm Thick Rendering In Cement Mortar 1:4 Complete All As Specified And As Directed By Engineer-In- Charge. 126 Material And Labour Granite (Of Any Type) Work (Table Rubbed And Polished) As In Steps, Pillars,Win Dow-Cills, Cooking Platforms And Like In Laid Over And Including 15 Mm Thick Screed In Cement Mortar (1:4) And Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Marble Shade And Roundening To The Edge Of Stone Slabs On Edges Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 127 Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid Dry Or Bedded And Pointed In Any Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 128 Demolition Of Cement Concrete Reinforced Of Any Discription And In Any Position, Including Reinforcement Cut As Required To Facilitate And Including Removing Rubbish Material From Building And Thrown In Low Lying Empty Area (As Per Direcction Of Age/Je) At Any Distance Upto 500 Metres From The Site Complete All As Specified And As Directed By Engineer-In-Charge. Note:The Weight Of Scrap Iron For Schedule Of Credit Shall Be Ascertain By Boo As Ordered By Ge.The Copy Of Boo Duly Countersinged By Ge Shall Be Enclosed With Final Bill. 129 Material And Labour For Reinforced Cement Concrete, Nominal Mix,1:2:4, Type-B1, Using 20 Mm Graded Stone Aggregate As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Including Proper Compaction By Using Mechanical Viberator Complete All As Specified And Directed. Note : Reinforcement And Form Work Shall Be Measured And Paid For Separately Under Appropriate Item Of This Schedule. 130 Supply And Fixing Pvc (Hdpe) Swr, 110 Mm Bore, Single Socketed In Any Length With Rubber Ring Joints Using Solvent As Per Manufacture Instruction, Fixed To Walls Complete All As Specified Including Fixing Of Pipe To Wall With Flat Irons Clamps Of Size 25 X 3 Mm, Bolts, Washers, Nuts, Nails Etc, After Taking Down Existing Damaged Rain Water Pipe Complete All As Specified And Directed 131 Material & Labour For In Repair 75 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 132 Material & Labour For 100 Mm Dia Pvc (Swr) Floor Trap Type B , Plain With Grating Including Jointing With Solvent Complete All As Specified And Directed By Engineer-In-Charge. 133 Material And Labour For Water Proofing Tratment To Roof / Terrace (Material Of Water Proof Treatment As Approved By Ge) Single Component, Acrylic Based, Flexible, Micro Fibre Reinforced Waterproofing And Heat Reflective Coating System. The Treatment Shall Be Carried Out As Per The Manufacturers Instructions And Shall Include The Followings:(A) Preparation Of Substrate And Cleaning It Off All Loose And Triable By Mechanical Means(B) Open The Cracks Lines To Form , V Grooves With Cutter/Hammer/Chisel Up To 5-10Mm And Filling With Crack Filler And Pu Sealant.(C) Application Of Primer Coat @ 0.2 To 0.3 Kg/ Sqm Followed By The First Coat @ 0.75Kg/ Sqm.(D) The Second Coat Shall Be Applied @ 0.75 Kg / Sqm And Reinforced With Fabric Re-Inforcement Between The First And Second Coat.(E) The Top Coat Of Primer Shall Be Applied After The Second Coat Dries Off @ 0.05-0.08 Kg Per Sqm.(F) The Material Shall Adhere To Following Specification. Technical Specification Of Materialtensile Strength 1.5 Mpa Astm D412Elongation At Break > 200% Astm D412Adhesion In Peel > 1.5 Mpa (On Concrete Substrate) En 1542Crack Bridging Ability Passes Upto 3.2Mm Width Astm C1305Permeability To Water Vapour Passes Is 2645Water Vapour Transimission ~ 23 G/M²/24Hr Astm E96Water Absorption 134 Material And Labour For 40Mm Average Thick Pcc Padding In 1:2:4 Type B-1 (Using 20Mm Graded Stone Aggregates) As In Roof Slab Finishing The Surface Even And Fair Using Liquid Water Proofing Compound Complete All As Specified And Directed. Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 135 Material And Labour For Making Benching With Pcc 1:2:4 Type- B0, Using 12.5Mm Graded Stone Aggregates Using With Liquid Water Proof Compound As Per ManufacturerS Instruction Along Side Wall Adjoining To Roof In Concave Shape Complete All As Specified And Directed. Note : Liquid Water Proofing Compound Shall Be Measured And Paid Separetly As Supply Only Under Appropriate Item Of Schedule A Boq. 136 Material And Labour For Cement Concrete 1:2:4 , Type B-2 Using 40 Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 137 Material And Labour For Water Proofing Compound Complete All As Specified And Directed. 138 Supply And Laying Dwcpe (Sn 8) Drain Pipes 150 Mm Nominal Dia As Per Is-16098 (Part-Ii), Laid In Trenches On Bed Including All Accessories/ Fittings/ Jointed Ring, Jointing And Testing Complete All As Specified And As Directed By Engineer-In- Charge.Note:- Excavation , Earth Work, Bedding And Pedestal / Anchorage If Required Shall Be Measured And Paid Separately Under Appropriate Item Of Boq/ Sch A 139 Material And Labour For Pcc (1:3:6) Type C-2 Using 40 Mm Graded Stone Aggregates As In Concrete Bed Of Sgsw Drain Pipes Of 150 Mm Bore, Laid To Required Slope Including Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And As Directed By Engineer-In-Charge. Note :- (I) Thickness Of Concrete Bed Below The Barrel Of Pipe Shall Be 10 Cm. (Ii) Width Of Concrete Bed Shall Be Outer Diameter Of Drain Pipes (Not Of Sockets / Collar) Plus 30Cm. 140 Material & Labour For Antitermite Treatment Along The External Wall Below Concrete Or Masonry Apron Using Chemical Emulsion @ 2.25 Litres Per Linear Metre Including Drilling And Plugging Holes Etc. In Apron/Plinth Etc., Complete All As Specified And As Directed By The Engineer-In-Charge. 141 Material And Labour For Att At Points Of Contact Of Wood Work By Chemical Emulsion (In Oil Or Kerosene Based Solution) @ 0.5 Litre/Hole By Drilling 6Mm Dia Holes At A Downward Angle Of 45 Degree At 150Mm Centre To Centre And Sealing The Same Complete All Sepecified And Directed By Engineer-In-Charge. 142 Material And Labour For Att Of Soil Under Existing Floors Using Emulsion @ One Liter Per Hole, 300Mm Apart Including Drilling And Plugging 12Mm Dia Holes With Cement Mortar 1:2 (1 Cement :2 Coarse Sand) To Match The Existing Floors Complete All Sepecified And Directed By Engineer-In-Charge. 143 Material And Labour For Writing Letters Or Figures (Block,Roman, Italic Ot Indian) Of Any Description, Not Exceeding 30Cm High With Paint Complete All Sepecified And Directed By Engineer-In-Charge. 144 Material And Labour For Cutting Into Existing Manholes For Connecting New Drains, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required For Internal Dia Of Pipe In 150 Mm Complete All As Specified And As Directed By Engineer-In-Charge. 145 Taking Down Cement Or Cement Lime Plaster On Brick Or Stone Walls, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. 146 Material And Labour For 15Mm Thick Rendering In Cm (1:6) (Internal Surface) On Other Than Fair Faces Of Brick Work Or Concrete Surfaces And Finishing Even & Smooth But Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 147 Material And Labour For Factory Made,Machine Pressed Precast Interlocking Paver Block 60 Mm Thick With Grey Cement And No Pigment, Any Shape And Size, Conforming To Is 15658-2006, Made Out Of M-35 Grade Concrete Laid Over Sand Cushioning Complete All As Specified And As Directed By Engineer-In- Charge. Note: The R Sand Cushioning Shall Be Measured And Paid Seperately Under Appropriate Item Of Schedule A Boq. 148 Dismantling Of Brick Tiles Or Terracing Tiles Single Layer On Roof & Disposal Of Retrieved Material Upto A Distance N.Exc 100M Where Directed, Complete All As Specified And Directed By Engineer-In- Charge. 149 Demolition Of Mud In Roofs, Any Thickness, Including Plastering And Leeping (Whether Full Thickness Removed Or Only A Part Thereof Disposal Off Rubbish Upto A Distance Not Exceedomg 500.00Mtr Where Directed ) Complete All As Specified And Directed By Engineer-In- Charge. 150 Material And Labour For 15Mm Thick Screed Bed Or Bedding Layear In Cement Mortar 1:4 On Roof Surfaces, Parapet Or Vertical Beam Surface (Horizontal Or Vertical) Finishing The Surfaces Even And Fair Complete All As Specified And Directed By Engineer-In-Charge. 151 Supply And Fixing Anodised Aluminium Handle, Fabricated Type 150Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 152 Supply And Fixing Aluminium Anodised Barrel Tower Bolt Of Extruded Section, 200Mm Long Complete All As Specified & Directed By Engineer-In-Charge. 153 Supply & Fixing Aluminium Anodised Sliding Door Bolts 300Mm Long, With Hasp And Staple (Bolt Type) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixed Complete All As Specified & Directed By Engineer-In- Charge. 154 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer Without Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 155 Supply & Fixing Factory Made Steel Window Confirming To Is 1038 With Side Hung Shutters Including Projecting Type Hinges, With Steel Handle, Steel Peg Stay, Complete, Dovetailed Welded, With And Including One Shop Coat Of Zinc Chromate Primer With Glazing Bars Including Making Good As Per Existing Surfaces Complete All As Specified & As Directed By Engineer-In- Charge.Note: The Rate Of One Shop Coat Of Zinc Chromate Primer Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 156 Supply Only 3.00 Mm Thick Sheet Glass Ordinary Quality ,Fixing With Oil Putty To Wooden Or Steel Surface N.Exc 0.5 Sqm Each Complete All As Specified And Directed 157 Material & Labour For Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, In Soft / Loose Soil Complete All As Specified And Directed By Engineer-In- Charge. Complete All As Specified And Directed By Engr-In-Charge. 158 Supply And Fixing For Mild Steel Screw Bolts 5Mm To 10Mm Dia Of Neck (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long Complete All As Specified And Directed By Engr-In-Charge. 159 Supply And Fixing For Pre -Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thickness Of Any Colour Having Atensile Strength Of 550 Mpa As In Roof Covering Fixed With L Type Or J Type Or Cranked Hook Bolts All As Specified And Directed By Engineer-In-Charge. 160 Material And Labour For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By Engr-In-Charge. 161 Material And Labour For Steel Work In Tubular Post 100Mm Dia Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Including Rolled Mild Steel Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. (Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated Of Gde Fe 410 -S, Complete All As Specified And Directed By Engr-In-Charge. 162 Supply And Fixing In Repairs Magic Eye For Flush/Panelled Door Shutter Etc Complete All As Specified And As Directed By Engineer-In-Charge. 163 Supply And Fixing Framed Work As In Doors Or Gates Of Angle Or Other Section With Gusset Plates, Rails, Braces, Etc., Complete, Drilled For Fixing Of Steel Sheeting Or Other Covering. Doors, Etc. To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings (Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Guides) Andhanging; Also Fastening And Fixing Complete Complete All As Specified And Directed By Engineer-In -Charge. 164 Material And Labour For Preparation Of New Steel Surfaces Of Any Description Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over With And Including One Coat Of Red Oxide Zinc Chrome Primer Complete All As Specified And As Directed By Engineer-In-Charge. 165 Material And Labour For Preparing Old Steel Surfaces Of Any Description Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In- Charge. 166 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed By Engineer-In- Charge. 167 Supply & Fixing 18Mm Thick Hdhmr Board Uv Coating, Exterior Grade As Approved By Ge, With And Including Acrylic High Gloss Sheet Of Min 1Mm Thick Over Hdhmr Board, Anti Fungal, Moisture Resistance, Anti Borer, As Per Is 14587 For Frame And Shutter For Kitchen Cabinets / Cupboards (Such As Side Wall, Shutter, Partition Back Side Of Etc. Of Cupboard And Cabinets). Complete All As Specified And Directed By Engg-In-Charge. 168 Supply & Fixing In Repairs Of Stainless Steel Cabinet / Drawers Handle Having A Length Of 250Mm And Shape Complete All As Specified And Directed. 169 Supply & Fixing In Repairs Of Partial Overlay / Fully Overlay Hydraulic Self Closing Concealed Hinges Having Size 103Mm X 64Mm Finish Of Nickel/Silver As Approved By Ge Complete All As Specified And Directed By Engg-In-Charge. 170 M&L For 40Mm Gi Pipe Medium Grade Made To Shape As In Spout Pipe As In Sunken /Verandah/ Balconey Complete All As Specified And As Directed. 171 Supply And Laying Or Fixing Or Laid In Trenches/ Ducts/ Through Pipes/ In Floors / Under Roads/ Hard Standing /Along Poles And Testing Lt Cable Xlpe, Pvc Insulated Screened, Bedded, Galvanised Steel Strip Or Wire Armourd Cable (Heavy Duty) 1100 Volt Grade With Aluminium Conductor Having Cross Sectional Area 70 Sqmm X 3.50 Core Conforming To Is-7098 (Part-I -1988) Complete All As Specified And As Directed By Engineer-In-Charge. (Excavation And Earth Work, Sand Cushioning & Gi Pipe Shall Be Measured And Paid For Separately) 172 Taking Down Carefully Copper /Aluminium Point Wiring (Light, Fan, Socket Or Power Point ) Complete Including Fitting Such As Hylem , Sheet Switches, Ceiling Rose, Pendent Holder , Sockets, Fan Regulator , Bell Push, Electronic Bell , Sunken Box Except Concealed Conduit Etc. Complete All As Specified And Directed By Engineer-In-Charge. Notes:(I) The Weight Of Aluminium Scrap , Copper Scrap And Iron Scrap Shall Be Ascertained By Boo As Ordered By Ge And Same Duly Countersinged By Ge Shall Be Enclosed With Final Bill. (Ii) The Rate Of Cutting Chases (As Required) And Making Good Surfaces To Match With Adjoining Surface Shall Be Measured And Paid Seperately Under Serial Item No. 173.00, 174.00, 175.00, 176.00, 177.00, 178.00, 179.00, 180.00, 181.00, 182.00, 183.00, & 184.00 Of Boq. 173 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps One Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 174 Material And Labour Point Wiring For One Light / Fan Point Controlled By 6 Amps Two Way Modular Switch Switch With 2.5 Sqmm Pvc Insulated, Unsheathed Multi Strand Copper Conductor Cable Fr-Lsh In And Including Concealed Pvc Conduit 20 Mm Dia Heavy Duty Isi Marked, Steel Terminal Sunken Boxes And 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point, Controlled By One Switch On The Same Board With Other Switch Or Independent Including Cutting, Chasing The Surface And Then Making Good The Same In Cm (1:3) Complete All As Specified And Directed By Engineer-In-Charge. (Note:- Switches, Sockets Etc Shall Be Measured And Paid For Separately Under Items Of Schedule). 175 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Same Board Complete All As Specified And As Directed By Engineer-In- Charge. 176 All As Per Item No 17400 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 6 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 177 All As Per Item No 174.00 Here- In -Before But For One 3/5 Pin, Modular Socket Outlet 5/15 Amp, On Independent Board Complete All As Specified And As Directed By Engineer-In- Charge. 178 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Bell/Buzzer Point Controlled By One Push Button On Independent Board But Not Below The Switch Board, Complete All As Specified And Directed By Engineer-In-Charge. 179 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For Modular Socket Outlet 3 Pin 6 Amp On Independent Board Complete All As Specified And Directed By Engineer-In-Charge. 180 All As Per Serial Item No 174.00 Of Boq Here-In-Before But For 15/16 Amp Socket Out Let By Using 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 181 Material And Labour For Point Wiring For One Light / Fan Point Controlled By One Switch With 1.5 Sqmm (Nominal Area) Pvc Insulated Unshealthed Multi Stranded Copper Conductor Cable Fr-Lsh In Existing Conduit And Provision Sunken Boxes But Inclyding 3 Mm Thick Phenolic Laminated Sheet Top Cover For Sunken Boxes Flush To Surface For One Light Point/Fan Point Controlled By One Switch And Fan Regulator Including Pvc Insulated Unshealthed 1.5 Sqmm Copper Conductor Cable Fr-Lsh Connected To Common Earth Dolly Complete All As Specified And Directed 182 All As Per Srl Item No 181.00 (Here-In-Before) But Socket 3 Pin 5 Amp 230 Volt Flush Type On Same Board 183 All As Per Srl Item No 181.00 (Here-In-Before) But For One Socket Point Outlet 3 Pin 5 Amp In Incdependent Board 184 All As Per Serial Item No 181.00 Of Boq Here-In-Before But For 15 Amp Socket Out Let By Using 1.5 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn 2.5 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete In Existing Conduit Complete All As Specified And As Directed By Engineer-In-Charge. 185 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 5 Amp Complete All As Specified 186 Supply And Fixing Switch Piano, Flush Type Single Pole, One Way 15 Amp Complete All As Specified 187 Supply And Fixing Socket Outlet 3 Pin, 5 Amp Flush Type All As Specified 188 Supply And Fixing 2 In 1, 3 Pin, 5 And 15 Amp Flush Type Complete All As Specified 189 Supply And Fixing Modular Switch One Way , 6Amp/10Amp ,1 Module, Single Pole, 250 Volts ,Ac Supply, Isi Marked , Complete All As Specified And Directed By Engineer-In-Charge 190 Supply And Fixing Modular Socket Outlet , 6 Amp-2/3 Pin Combined 2 Module , 230 Volts , Multipurpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 191 Supply And Fixing Modular Switch One Way 16 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 192 Supply And Fixing Modular Switch Two Way 6 Amp, Single Pole, 1 Module 230 Volts , Ac Supply , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 193 Supply And Fixing Modular Bell Push Switch 6A 1 Module , Isi Marked Complete All As Specified And Directed By Engineer-In-Charge.Note: (I) Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 194 Supply And Fixing Modular Socket Outlet 6Amp/16Amp-2/3 Pin Combined,2 Module ,230 Volts ,Multi Purpose, Ac Supply, Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 195 Supply And Fixing Fan Regulator, Modular Type, 5 Step, High Speed, Two Module Complete All As Specified And Directed By Engineer-In-Charge. 196 Supply And Fixing Ceiling Rose 3 Terminal Flush Type 6 Amp 250V ,Isi Marked ,Ac Supply, Topline Series With Polycarbonate 20Mm X 50 Mm Two To Three Terminal, Complete All As Specified And Directed By Engineer-In-Charge. 197 Supply And Fixing Electric / Electronic Bell, Ding Dong Type 230 Volt Ac Supply,Isi Marked Complete All As Specified And Directed By Engineer-In-Charge. 198 Supply And Fixing Wall Mounted Extruded Aluminium/Polycarbonate Led Batten Fixture T8(G13 Holder) 1.2 M Including One Led Retrofit Tube 20(±10) Watt. 1.2 M T8 6500 Efficacy Not Less Than 90 Lumen/Watt Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete Including Making Connection Complete All As Specified And Directed 199 Supply And Fixing Lamp Holder ,Isi Marked Of Pvc/Polycarbonate Type With Back Plate Suitable For Batten Fitting With And Including 9Watt Led Retrofit Lamp (Base B-22) Complete All As Specified And Directed By Engineer-In-Charge. 200 Supply And Fixing Lamp Holder Pvc/ Polycarbonate Type With Back Plate Suitable For Batten Fitting With Led Bulb 5 Watt Lamp Base- B-22 Complete All As Specified And As Directed By Engineer-In- Charge.Note: Labour Element For Taking Down Old Unservicable Material Is Included In Serial Item No.172.00 Of Boq Here-In -Before And Nothing Shall Be Extra Paid On This Account. 201 Supply Only Led Bulb 9 W (Suitable For B22 Base), 250V Ac, Green/Red/ Clear Day Light ( Cdl) In Colour Complete All As Specified And Directed By Engineer-In-Charge.As Per Direction Of Engineer-In-Charge Colour Of Led Luminiure Cdl/Warm White Shall Be Provided By The Contractor As Per Site Requirment And Nothing Shall Be Paid Extra On This Account.Notes:(A) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Led Bulb Complete Including Lamp/ Strip From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led Bulb . (B) All Led Bulbs Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (C) Scope Of Work Shall Include To Fix Led Bulb Walls/Ceiling Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account.(D) Old Unservicable Retrieved Material Shall Be Deposited In The Store Yard Of Age E/M Ge (North) Bathinda By The Contractor His Own Arrangements And Nothing Shall Be Paid Extra On This Account. (E) The Rate Of Electric Connection Connecting With Using Flexible Copper Wire Twin Core Upto Ceiling Rose/Connector Is Included In This Item And Nothing Shall Be Paid Extra On This Account. 202 Supply And Fixing In Replacement Led Panel Light Fitting Recessed Mounted,Square Shaped Of Size 600Mm X 600Mm , 36 (±10%) Watt, Efficacy Not Less Than 100 Lumen/Watt , Extruded Aluminium/Polycarbonate, Pc Diffusor And Inbuilt Driver Complete As Per ManufacturerS Instructions With And Including Connection With Flexible Twin Core Copper Cable Of Size 23/.00076 From Ceiling Rose To Fitting Complete All As Specified And As Directed By Engineer-In- Charge. 203 Material And Labour In Replacement Sub Main Wiring Complete With Two Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh With And Including Single Core 6 Sqmm,1100 Volts Grade, Pvc Insulated, Multi Stranded Copper Conductor Cable Frlsh For Earth Wire In Existing Pvc Concealed Conduit (Colour Code Phase-Red, Neutral-Black And Earth As Green) Complete All As Specified And Directed By Engineer-In-Charge. Notes:-(A) Three Single Core 6 Sqmm Frlsh Pvc Insulated Unsheathed With Multistranded Copper Conductor Cable 1100 Volts Grade Shall Be Measured As One Length. 204 Supply And Fixing In Replacement Mcb 40Amp -63 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 205 Supply And Fixing In Replacement Mcb 6Amp -32 Amp Sp ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 206 Supply And Fixing In Replacement Mcb 32 Amp Spn ,240Volt , Rupturing Capacity 10 Ka , Curve ‘C’ Isi Marked, Complete All As Specified And Directed By Engineer-In-Charge. 207 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 8 Way 240 Volt, Ip -54, 200 Amps Rated Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 208 Supply And Fixing Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Double Door, Powder Coated Db Spn 12 Way 240 Volt, 200 Amps Rated Copper Bus Bar, Dust And Vermin Proof Suitable For Incorporation Of McbS And Isolators Etc Complete Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 209 Supply And Fixing In Replacement Sheet Metal Enclousers Made Out Of Crca Mild Steel Sheet Not Less Than 1.2Mm Thick,, Ip-54 Protection, Flush Mounted For Metal Door, Powder Coated Db Tpn 4 Way, 415 V Ac With 63 Amps Rated Bus Bar, Double Door, Dust And Vermin Proof Suitable For Incorporation Of Incoming Mccb And Outgoing Mcb Sp/Tp And Earth & Neutral Bus Bar Etc Complete All As Specified And As Directed By Engineer-In- Charge.Note: Mcb/ Isolators Shall Be Measured And Paid Seperately Under Appropriate Item Of Boq. 210 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 20 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 211 Supply And Fixing Wall Mounted Extrdued Aluminium Housing Led Betten Fixture With Tube 1.2 M, 25 Watt Inverter Type, 1.2 M 3000/6500K, Efficacy Not Less Than 90 Lumen/Watt, Extruded Aluminium/Polycarbonate, Pc Diffusor And Integrated Inbuilt Driver Complete Including Making Connection Complete All As Specified And As Directed By Engineer-In- Charge. 212 Supply And Fixing Led Batten Fitting 1X10 Watt, 6500K, 2 Ft Complete With Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Polycarbonate Environment Friendly, Energy Efficient Complete With All Light Connection All As Specified And Directed 213 Supply And Fixing In Repair Led Street Light Fitting 35 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminium Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Complete With Ip 65/66 Protection Including Fixing With Gi/Ms Bracket Made Out Of Suitable Size Of Light Grade Tube Upto 1.2 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Iron With Suitable Bolt And Nuts Complete With Making Connection Complete All As Specified And Directed 214 Supply & Fixing Building Security Led Light Of 35 Watt , Ip 66 , Luminaire With High Power With Toughened Glass Complete As Per ManufacturerS Instructions With And Including Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt ,Nuts And Washers Complete And Fixing To Wall / Column With And Including Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size And Testing Complete All As Specified And Directed By Engineer-In-Charge. Notes:(A) The Rate Of Bracket Made Out With 40Mm Bore Galvanised Iron Light Grade Pipe 1.20 Mtr Length Bent To Shape With 02 Sets Of Ms Clamps Made Out Of Minimum 3 Mm Ms Flat Iron With Suitable Bolt And Nuts And Electrical Connection With 1.5 Mtr Long Twin Core Round Copper Conductor Cable Of Suitable Size Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (B) Contractor Has To Furnish A Replacement Warranty Of 02 Years For Security Led Light Fittings Complete Including Lamps From The Certifiy Date Of Completion Of Ca. The Product Will Be Replaced Free Of Cost In The Following Case :-(I) Manufacturing Defects.(Ii) Failure Due To Mechanical And Electrical Impact. (Iii) Drop In Lumen (Or Lux At 1 M) Below 90% Of Clamied Values Of Lumen(Or Lux At 1 M) Of The Led /Luminaries. (C) All Security Led Light Must Meet The Provision Laid Down In Is - 16101, 16102 Part -I/Ii,16103 Part -I, 16104,16105,16106, 16108/2012 And 15885 Part -Ii / Section 13. (D) Scope Of Work Shall Include To Fix Security Led Light Fittings Walls/Building Which Includes Needful T & P And Required Accessories Etc If Any, Complete Including Making Connection, Testing Etc Complete. No Extra Payment Is Admissible On These Account. 215 Supply And Fixing Jointing Of Double Walled Corrugated Pipe (Dwc) As Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 216 Supply And Fixing Jointing Of Snap Fit Coupler For Double Walled Corrugated Pipe (Dwc) Of Ug Cable Protection Complete Of Size 63 Mm, Complete All As Specified And Directed By Engineer-In-Charge 217 Supply And Fixing Mccb With Adjustable Type, 4 Pole, 63 Amps, 415 Volts, 50 Hz, 25 Ka And Including Sheet Metal Enclosure Out Door Type Made Out Of 3.15 Mm Thick Crca Sheet Mounted On Angle Iron Padesta Including Grouting Complete All As Specified And Directed By Engineer-In-Charge. 218 Material And Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600Mm X 600Mm X 6 Mm Thick Burried Directly In Ground To Depth Of Pit Not Less Than 2.25 M Below Normal Ground Level With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Surrounded From All Sides By 15 Cm Thick Packed Layer Of Charcoal / Coal Dust And Common Salt Filling In Alternate Layers And Connected To Galvanised Earth Lead Wire 4 Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Gi Or Steel Including Gi Protection Pipe 15Mm Dia Light Grade Upto The Extent Of 7.5 Metre And Connecting To Earthing Test Point, Main Switch Board Including Gi Pipe 20 Mm Dia Light Grade For Watering, Ms Funnel And Bringing Out The Watering Pipe Upto 30 Cm Above The Normal Ground Level Plugged At Top Including All Fitting Including Pcc Earth Pit With Pcc 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate And Rcc Pit Cover Including Necessary Earthwork And Excavation In Any Type Of Soil Complete All As Specified As Shown In Electrical Plate No 3 Of Ssr Part-I And Testing On Completion. Note:- (I) Earth Continuity Of Gi Wire 4 Mm Including Protection Pipe Up To 7.5 Mtrs From Earth Electrode Will Be Included In Unit Rate, Complete All As Specified And Directed. (Ii) The Rate Of Earth Work In Soft/Loose Soil I.E. Excavation, Returing Filling And Removal, Form Work Is Included In This Item And Nothing Shall Be Paid Extra On This Account. (Iii) Pcc Chamber Shall Be Constructed At Least 1.5 Metre Away From The Earth Electrode And Pipe For Watering Shall Be Provided In Slanting Manner. (Iv) The Earth Testing Arrangement Should Be Done By The Contractor As Per Direction Of Engineer-In-Charge. 219 Supply And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Strandred Conductor 6Sqmm, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Mtr Apart Including 4Mm Suspenstion Wire, One Twin Core Cable Flat All As Specified And Directed 220 Supply And Fixing In Replacement Exhaust Fan 300Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 221 Supply And Fixing Exhaust Fan 250Mm Sweep (Heavy Duty) Steel Body, Bee, 5 Star Rated ,Ac Supply, Single Phase ,230 Volts, 50Hz,1200Rpm With And Including Frame Including New Mosquito Stainless Steel Wire Mesh Of Guage 0.36Mm With Suitable Wooden Frame Protection Against Birds Etc. Mounted In Suitable Opening Arrangmement In Wall And Electric Connection With And Including Three Core Pvc Insulated Pvc Sheathed Copper Conductor Flexible Cable 24/0.2Mm Drawn In Flexible Pvc Conduit And Hanging On Wall With 04 Nos. Steel Fastners 10Mm Dia 100Mm Long With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 222 Taking Down Unserviceable Complete Ceiling Fan Along With Blades And Deposited To Age E/M Store Yard Of Ge (South Bathinda) Complete All As Specified And Directed By Engr-In- Charge. 223 Supply & Fixing Ceiling Fan Of 1200Mm Sweep Complete With Blades, Down Rods, With And Including Remote Control, Single Phase, 50 Hz, Min Air Delivery 210 Cfm With Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current (Bldc) Motor Connecting Up Complete With And Including Three Core Flexible Pvc Insulated Multi Stranded Copper Conductor Cable Of Suitable Size From Ceiling Rose / Connector, Including Extra Gi / Ms Pipe Down Rod, As Per Site Requirement , With And Including Serial Number Of Fan As Issued By Engineer-In-Charge And Ge Office Name With Red Colour Permaent Marker Complete All As Specified And Directed By Engineer-In-Charge. 224 Dismantling And Taking Down Of Existing Energy Meter And Refixing The Same Complete All As Specified And Directed By Engineer-In- Charge, 225 Dismantling And Taking Down Existing Geyser And Deposit In The Safe Custody / Store Yard Of Age E/M Of Ge (S) Bathinda And Refixing The Same After Carring Out Repair Work/ Rewiring Accn )Complete All As Specified And Directed By Engineer-In- Charge,
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
17.
Defence #11200248 Price Bid
Tender for Sch A Part-I To Xii Note: This Schedule Is Pre-Priced By Mes And The Rate Indicated Under Col 5 Signifies This Fact Only , Total Amount Of Sch A Part-I (Building And Structures) , Total Amount Of Sch A Part-Ii (Site Clearance, Excavation And Earthwork) , Total Amount Of Sch ‘A Part Iii (Internal Water Supply) , Total Amount Of Sch ‘A Part Iv (Internal Electric Supply) , Total Amount Of Sch ‘A Part V (Road, Path And Culverts) , Total Amount Of Sch ‘A Part Vi (Sewage Disposal) , Total Amount Of Sch ‘A Part Vii (Area Drainage) , Total Amount Of Sch A Part-Viii (External Water Supply) , Total Amount Of Sch A Part-Ix (External Electric Supply) , Total Amount Of Sch A Part-X (Lightning Protection) , Total Amount Of Sch A Part-Xi (Air Conditioning & Cooling Appliances) , Total Amount Of Sch A Part-Xii (Dg Set) , Schedule A Part-Xiii (Miscellaneous B/R And E/M Works) Note: This Schedule Is Not Pre-Priced By Mes And The Rate Indicated As Rs 0.00 Under Col 5 Signifies This Fact Only. , S & F Square Profile Led Lighting Fixture With Extruded Polycorbonate,Environmental Friendly,Energy Efficient Ready To Use Pack Led Tube Light Fitting 20 Watt With Led Light Source 6500K With Uniform Light Output, With All Accessories Including Its Connection Complete With All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Factory Made Powder Coated Sheet Metal Enclosure, Tpn Vertical Distribution Boards With Mccb As Incomer Ip43 Protection Double Door : Plain 4 Way With Suitable Rated Busbar, Neutral Link, And Mcb Sp/Tp As Outgoings Complete All As Specified And Directed. Note :Mccb And Mcbs Are Not Included In This Item And Paid Separately. , S&F Mccb 4 Pole, 415 V, Adjustable Type Thermal Magnetic Release, 100 Amps With Breaking Capacity 25 Ka And Making Connection With Suitable Size Of Copper Lugs Etc Complete All As Specified And As Directed. , M&L For Preparation Of Road Surface And Applying Thermoplastic Reflective Paint For Marking Of Minimum 2.0 Mm Thick Single Coat As A Centre Line Or Edge Line Etc, Road Marking N Exc 100 Mm Width Using Thermo Plastic Paint (Hot Application) White/Yellow By Indigenous Modern Propelled Road Marking Machine As Directed Including All Ingredients Such As Binder, Glass Beads, Titanium Dioxide, Calcium Carbonate, Inter Fillers Etc, Thermoplastic Requirement For Glass Beads Shall Be Confirming To Bs-6086 Of Most Specification Including Spraying Of Glass Beads Etc Complete All As Per Manufacturers Instructions And Complete As All Specified And Directed. , M&L For Construction Of Valve Pit/Chamber Of Internal Dimensions 900 Mm X 900 Mm X 900 Mm, Using Plain Cement Concrete 1:4:8, Type D-2, Using 40Mm Graded Stone Aggregates For Foundation, 23 Cm Thick, Brick Wall Built In Cement Mortar (1:4) ,15 Mm Thick Rendering All Around The Brick Work In Cement Mortar (1:6), 75 Mm Thick Plain Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregates In Coping Including Necessary Form Work, 3 Coats Of White Wash On Rendered Surfaces And On Coping, 5 Mm Thick Mild Steel Top Sheet Cover With Frame Made Out Of 40X40x6 Mm Angle Iron, Locking Arrangement, Including Painting Of Steel Surface With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer All As Specified And As Directed. , Cutting Existing 80 Mm Dia Pipe For Inserting Tee Of Size 80X80x40 Mm Including Lead Joint And Excavation Etc Complete All As Specified And Directed , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 110 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24, 450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed. , Supply And Laying Double Walled Corrugated (Dwc) Hdpe Pipe Of Nominal Bore 50 Mm Including 90 Degree Bends With Coupler And Rubber Ring, Conforming To Is :16205 Part 24, 450 N Laid In Trenches For Cable Protection Complete, All As Specified And As Directed. , Supply, Install, Testing And Commissioning, Factory Made And Tested (Including Cpri Type Test Certified) Lt Panel Board Out Door Type, Floor Mounted, Compartmentalised And Ip-63 Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, All As Specified And Directed, Having Bus Bar Chamber With Insulated Aluminium Bus Bars 300 Amps Rating Installed On Porcelain Insulators. The Panel Shall Be Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet And With Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Front And Rear Opening Type With Aprons For Cable Entry With Double Door Shutter And Locking Arrangement With And Including Following Items. (Notes : The Rate Quoted Shall Include Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ).Note: Panel Board Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. , Incoming:- (A) Mccb 4 P, 415 Volt 200 Amps, 36Ka, 50 Hz With Fixed Thermal And Magnetic Setting -01 No Outgoing:- (B) Mccb 4 P, 415 Volt 100 Amps, 25Ka, 50 Hz -03 Nos. (C) R,Y,B Indicators (D) Multifunction Digital Square Type Intelligent Panel Meter To Measure Voltage, Current, Frequency, & Power Factor - 01 No , Supply, Install, Testing And Commissioning Of Silent Diesel Engine Generating Set, 125 Kva/100 Kw, 1500 Rpm, 3 Phase, 415 V, 50 Hz, Power Supply Alternator Along With Fuel Tank, Control Panel., Battery And Complete Set Installed In Sound Acoustic Enclosure And Standard Accessories And Fittings With Power Factor 0.8, Plain Cement Concrete Foundation Suitable For The Generator Set As Per Manufacturers Instructions Complete With Standard Accessories And Microprocessor Based Integrated Dg Set Controller With Coupled To Alternator Rated At 125Kva/100 Kw At 415 Volts, Set Mounted On Channel Iron Base Frame Complete With Sub-Base With Batteries, Avm Pads And Std Panel All As Per Guideline Of Latest Cpcb Iv+ Norms All As Specified And Directed And Comprising Of The Following: Make: Kirloskar/Greeves/Cummins , (I) Engine: Engine With Direct Injection, Water Cooled, 3 Cylinders, In-Line,4 Strokes Rated At Developing 1551 Bhp @ 1500 Rpm For Continuous Duty Of Suitable For 125 Kva Alternator With Provision Of 10% Over Load For One Hour In Every 12 Hour Running Confirming To Bs 5514/ Iso 3046 Standard Totally Enclosed As Per Oem Specification And Directed By Engr-In-Charge. The Engine Has The Following Specification:- A) Mechanical Fip B) Mechanical Governor C) Turbocharger, Exhaust Manifold, Stainless Steel Exhaust Flexible Connection D) Radiator Cooled, With After Cooled E) Plate Type Lube Oil Cooler F) Filters G) Lube Oil H) Dry Type Replaceable Paper Element Air Cleaner J) Flywheel Housing And Flywheel To Suit Single Bearing Alternator K) Starting Motor-Electric, Battery Charging Alternator L) First Fill Lube Oil And Coolant (Ii) Alternator: Brushless Alternator, Self -Excited, Self -Regulated, Floor Mounted With All And / Or Roller Bearings, Statically And Dynamically Balanced Screen Protected Acoustic Enclosure Confirming To Is 4722 / Is 13364, Ip-23 Protection With H Class Insulation Limited Temperature Rise Of Class H, Automatic Voltage Regulator From No Load To Full Load, Ammeter Capacity Of Delivery 125 Kva, 415 Volts, 3 Phase, 50 Hz And Lagging For Ac Supply And Will Be Suitable For Tropical Conditions All As Per Oem And Directed By Engr-In-Charge. (Iii) Instrument Panel : Engine Instrument Panel Consisting Of On/Off Starting Switch With Key Lubricating Oil Pressure Gauge, Water Temperature Gauge, Battery Charging Indicating Lamp, Hour Meter With Rpm Indicator, Safety Control Against High Temperature Of Water, Over Speed Stop With Double Driver Adopter As Per Oem Specification And Directed By Enge-In-Charge. , (Iv) Other Fittings: (A) Battery Charger : Battery Charger Having Electric Circuit Consisting Of Rectifiers, Capacitors And Resistance Etc. The Battery Charger Should Be Able To Charge 12 Volts 88 Ah Battery At A Time (V) Dg Set Shall Be Supplied Along With Acoustic Original Enclosure Of The Manufactures Suitable For 125 Kva Dg Set And All Connecting Accessories As Per Latest Cpcb Iv+ Norms (Vi) The Diesel Oil, Lub Oil Etc. For Smooth Functioning Of Dg Set During Ph-I & Ph-Il Complete Testing And Full Tank Filing Of Diesel Oil After Ph-I & Ph-Ii Testing, Topping Of Lub Oil Etc. Required For Commissioning And Testing Of Dg Set. (Vii) Amf Panel: - Supply Installing Commissioning & Testing In Microprocessor Based Amf Panel Board Factory Made, Out Door Type Ip-65, Cubical Type, Vermin Proof, Dust Proof, Water Proof Made Out Of 3.15 Mm Thick Crca Sheet And Angle Iron Frame Of Size 50X50x6 Mm Inside Depth Not Less Than 50 Cm And Size Suitable To Accommodate The Following Accessories With Insulated Tpn Copper Busbar Of Rating Not Less Than 1.5 Times The Rated Capacity Of The Incomer Mccb Suitable For 125Kva Dg Set. Hinged Door With Locking Arrangement Duly Painted With Coat Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Both Internally And Externally And Connecting With Cable With Lugs Including Internal Wiring With Copper Cable Of Suitable Size Using Lugs Compressing The Following Accessories All As Directed. (Notes : The Rate Quoted Shall Include For Earth Work & Excavation For Angle Iron Frame For Foundation Of Panel Board Upto 0.50 M Below Gl In Any Type Of Soil & Plain Cement Concrete (1:4:8), D2 Filling In Foundation The Ground Clearance Of Panel Board Shall Be 0.40 M Gl To The Bottom Of Panel Board ) And Copper Bus Bar 240 Amps Duly Colour Sleeved Mounted On Epoxy Insulators-01 Set. Note:(I) Amf Panel Suitable For 100 Kva Dg Set To Connect With Grid Shall Be Approved By Cpri And Certificate To Be Produced And To Be Submitted In The Office. The Amf Panel Has The Following Specification:- A) 200A, 4 Pole Contactor For Alternator With Thermal Over Load Relay B) 200A, 4 Pole Contactor For Mains C) Mcb For Short Circuit Protection D) Indication Led (Dg On, Load On Dg, Main On, Load On Main, Battery Charge On) E) Push Buttons (Engine Start/Stop, Generator Contactor Close/Trip, Main Contactor Close/Trip If Provided, Fault Accept/Reset) F) Voltmeter & Ammeter And Other Connecting Accessories And Safety Features For Successful Auto Operation Of 125 Kva Dg Set. (Viii) Excavation, Earthwork And Provn Of Plain Cement Concrete Plinth Of Suitable Sizes For Installation Of Dg Set & Connected Accessories Complete As Per Oem/ Site Requirements. , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 2.0 Kva Complete All As Specified And As Directed By Engr-In- Charge. Makes :- Automatic Electrical (Ae)/ Vinitec/Aplab/V Guard , Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 3.0 Kva Complete Suitable For Inverter Type Ac All As Specified And As Directed. Makes :- Automatic Electrical (Ae)/ Vinitec/Aplab/V Guard / Volina , S&F Two-Way Bib Taps 15Mm Dia, With Wall Flange And Aerator Screwed Down For Iron Pipe Or For Brass Ferrule Complete All As Specified And As Directed. Make: Cat No. F1015161 Of Cera Or Techno Commercially Equivalent Model Of Appendix C Makes.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
Maharashtra View Result →
18.
Defence #11198549 AOC
Tender For Spl Repair To Certain Md Accn In Kandhar Line Under Ge Central Delhi Cantt-10; 1 Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubbing down with water etc including remove alldebris at 2 KM away from site complete all as specified and directed. 2 M&L for 15 mm thick rendering in cement mortaron fair faces of brick work or concrete surfaces, applied in two layers i.e. 1st layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd (top) layer of 5 mm thick rendering in cement mortar (1:4 )mixed with WPCfinished even and fair etc complete all as specified and directed.(Note:- WPC shall be measured and paid separately) 3 M&L for rendering 10 mm thickin CM 1:6 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 4 M&L for rendering 5 mm thick in CM 1:3 on ceiling concrete surfaces finished even and fair without using extra cement complete all as specified and directed. 5 M&L for preparation of new plaster surfaces of wall and applying water proof wall putty 1-2 mm thickness over plastered surfaces to prepare the surfaces even and smooth and finishing walls with Two coats @ 1.67 ltr/10 Sqm each acrylic smooth exterior paint of required shadeover and including priming coat of exterior primer @ 2.20 Kg/10Sqm complete all as specified and directed. 6 M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper complete all as specified and directed. 7 M&L for Preparation of new surfaces (Plastered or un-plastered) of ceiling and applying two coats of oil bound distemper complete all as specified and directed. 8 M&L for complete removal of existing treatment of old decorated plastered or unplastered surfaces of wall by rubbing , brooming down, washing with water etc and applying two coats of oil bond distemper complete all a specified and directed. 9 M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing tretament, by rubbing brooming down, washing with water etc and providing and applying 1-2 mm thickness wall putty over plastered surfaces to prepare the surface even and smooth and finishing wall surfaces by applying Two coats @ 1.67 ltr/10 Sqm each with acrylic smooth exterior paint of required shade over and including priming coat of exterior primer @ 2.20 Kg /10Sqm complete all as specified and directed. 10 M&L for dismantling water tanks of capacity exc 250 litres & n. exc 500 litres complete all as specified and directed. 11 M&L for rotational moulded polyethylene water storage tanks (ISI Marked) white colour 500 litres capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PTMT float valve, lid tank cover for polyethylene and polyethylene ball complete all as specified and directed. 12 S&F 15 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 13 S&F 20 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed 14 Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer) complete all as specified and directed. 15 Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thickness removed or only a part thereof) complete all as specified and directed. 16 Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting pointcomplete all as specified and directed. 17 M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone crushed aggregates) on roof padding, surface finished even and smooth without using extra cement complete all as specified and directed. 18 M&L for providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer or equivalent (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalentcomplete all as specified and as per manufacturers instructions. 19 M&L for providing and applying Smartcare Dampproof or equivalent, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per manufacturers instructions and all as specified & directed. 20 Supply only integral water proofing compound (ISI marked) complete all as specified and directed 21 Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified and directed 22 M & L for brick work with Cement Mortar 1:6 using sub class B bricks, old size, straight or curved on plan exceeding 6 m mean radius complete all as specified and directed. 23 All As per item no 22 before but except bricks etc complete all as specified & directed 24 Material and labour for brick work with sub class B bricks of old size, straight or curved on plan exc 6m mean radius in half brick walls, in CM 1:4 complete all as specified and directed. 25 Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed 26 Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified & directed 27 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified & directed. (M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 28 S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified & directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). 29 S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65 x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non-toxic additives (max toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr incharge. Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. 30 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 31 S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer?In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately).Note: MTC and Screw Out Test shall be provided by Contractor 32 Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER consisting of density 650 kg/cbm manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strength and safety purpose (confirming as per IS 4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. SS butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws, etc. complete all as specified& directed.”Note: MTC and Screw Out Test shall be provided by Contractor 33 S&F Aluminium windowfor outer frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter(02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm ss 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed. 34 S&F Aluminium windowOuter frame 40mmx114mm with 1.3mm thickness ,corner 45 degree cut & aluminum welded center mullion size 40mmx65mm also welded, shutter (02) size 40mmx60mm 1.3 thickness 45degree cut mechanically joint with 6mm alen key bolt clamp , 12mm SS 202 grade round bar at 100mm cc distance in middle 150mm cc distance for safety grill welded at both ends with 6mm SS 202 grade round bar, 5mm clear glass both side EPDM rubber gasket metal body hand lever type single point lock , aluminum kobra hinges 2 nos per shutter , 40x18mm 45 degree cut & welded mosquito net shutter(02) with 0.45mm nominal dia of SS wire mesh,SS 75mm long hinges & pvc magnet,full system powder coating with pure polyster coat of any shade as approved by GE and installing with SS screw roll plug and filled with silcone complete all as specified and directed. NOTE:- For installation of windows AC/desert cooler the provn of window glass shutter with wire mesh,grill and necessary fittings and locking arrangement for subject portion will be modified as per ground requirementt during execution as direction of Engg-in-Charge. 35 S&F ventilator outer frame 40mmx40mm with 1.3mm thickness, corner 45 degre cut & aluminum welded center mullion size 40mmx65mm also welded , fixed 5mm frosted glass EPDM rubber gasket with provision for fresh air fan, full system powder coating with pure polister coat of any shade install with SS screw rol plug pvc & silicone complete all as specified & directed 36 Dismantling of wall and ceiling/cupboard board fibre pulp AC boards etc any thickness including cover fillets removing the wiring complete all as specified & directed 37 S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbmhaving good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws complete all as specified & directed. Material test certificate and authentication should be compulsory provided by the contractor. (For WC/Bathroom/Toilet/Kitchen and Cabinets) 38 S&F stainless steel continuous (Piano) hinges, bright finish, width of flap when open 30mm, complete all as specified & directed. 39 S&F of stainless steel handles 100 mm sizefor kitchen cabinet shutters and bed room cub boards complete all as per specified and directed. 40 S&F brass chromium plated tubular hanger rod 20 mm dia with suitable brackets complete all as specified and directed. 41 S&F for PVC magnetic door catches of kitchen cabinet and similar work fixed with MS screws complete all as specified & directed 42 S&F SS butt hinges medium weight 100mm size fixed with SS screws (ISI Marked) complete all as specified & directed 43 S&F SS barrel tower bolt extruded section 150mm long and fixed with SS Screws (ISI Marked) complete all as specified & directed 44 S&F 150mm extruded SS handle fabricated type and fixed with SS Screws(ISI Marked) complete all as specified & directed 45 S&F 300mm extruded section SS sliding door bolt with hasp and staple and fixing bolt and nut (ISI Marked) complete all as specified & directed 46 S&F for 300 mm MS ordinary rat tail rod pattern spring including roller and roller plate complete fixed on wooden frame or on wall with wooden plugs and set in cement mortar complete all as specified & directed. 47 M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed 48 M&L for preparation of Old or previously treated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified & directed. 49 S&F for stainless steel plate rack of size 90x80x25 cm depth size made out of 1mm thick sheet complerte all as specified and directed. 50 S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen with plug, washers, waste pipe, waste coupling incl fixing cast iron cantilever bracket connecting union over all size 915x460mm with bowl size410x330x160mm complete all as specified and directed. 51 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm etc complete all as specified & directed 52 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm etc complete all as specified & directed 53 Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 40mm etc complete all as specified & directed 54 Supplying and laying 16 mm dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified complete all as specified and directed 55 All as per item No. 54here in beforebut 20 mm dia complete all as specified and directed. 56 All as per item No. 54 here in beforebut 40 mm dia complete all as specified and directed. 57 S & F Floor door stopper 150mm size of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed 58 Cutting chases, pinning in, for brick walls built in cement mortar, making good to facings where required and pointing in cement mortar 1:3 or PCC 1:2:4 type B-O(using 12.5 mm graded aggregate) as required for concealed water tubing etc cutting exceeding 10cm girth but not exc. 20 cm complete all as specified & directed. 59 Supply and fix in repairvitreous China wash hand basin (including pedestal)white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper and waste pipe & waste coupling including all necessary fitting and fixtures complete all as specified & directed 60 Supply and fix in repairs vitreous china squatting pan Orissa pattern long pan size 580x440mm white with integral foot rests ‘standard Grade P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe) complete all as specified and directed, 61 S&F in repair vitreous china wash down water closet EWC white/ ivory/off white (closedpattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flushpipe) complete in all respect complete all as specified & directed 62 Supply only PVC low level white flushing cistern valveless symphonic action type 5/10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified & directed 63 S&F in repairs 15 mm dia 600mm long PVC connectionswith brass check nut complete all as specified & directed 64 S&F in repairs Glass Corner Shelf 6mm thick including CP railing radius 250mm complete all as specified and directed by Engineer-in-Charge. 65 S&F in repairs Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railingcomplete all as specified and directed by Engineer-in-Charge. 66 S&F in repairsHealth faucet, CP brass with 1.50m long flexible pipe complete all as specified and directed by Engineer-in-Charge. 67 S&F fancy type brass chromium plated toilet paper holder, complete all as specified & directed 68 S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule Make-Jaquar/marc/Kohlar, complete all as specified & directed 69 S&Fin repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as specified & directed 70 S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as specified & directed 71 S&Ffor 15 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed 72 S&Ffor 20 mm bore gate valve, gun metal, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed 73 S & F in repairs Chromium plated brass overhead shower with arm complete all as specified and directed. 74 S&F in repairs looking mirror of size 600mmx450mmx5.5mm thick with aluminium frame selected quality mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 75 S&F in repairs Brass chromium plated mode 2 in 1 WHB mixture model Quarter half turn (SOLO) omplete all as specified & directed. 76 S&F in repairs brass chromium plated mode 3 in 1 wall mixture model Quarter half turn (SOLO) complete all as specified & directed 77 S&F in repairs Brass chromium plated mode 2 in 1 sink mixturemodel Quarterhalf turn (SOLO) ofas complete all as specified & directed. 78 S&F in repairs chromium plated soap dish fancy type complete all as specified & directed 79 S & F in repairtowel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embedded in cement mortar 1:3 with MS screws etc complete all as specified and directed. 80 Dismantling of floor of size not exceeding 4.00 Sqm each for EWC and removing out the cinder/concrete from sunken protion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditons, grinding any sharp edges etc all as specified and directed. (a) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite.(c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified.(d) M&L for providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall.(e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(f) The area of Each WC portion is n.exc 4.00Sqm each.(g) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note : The work will be executed by authorised manufacturers/applicator. 81 Dismantling of floor of size not exc 1.50 Sqm for IWC and removing out the cinder/concrete from sunken protion, cleaning of RCC surface to remove dust, loose particle with compressed air or any other suitable method depending on site conditons, grinding any sharp edges etc all as specified and directed. (a) Cleaning or RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc.(b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite.(c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified.(d) M&L for providing 25mm dia GI pipe spout projecting at least 150mm beyond outer face of wall.(e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed.(f) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account.Note : The work will be executed by authorised manufacturers/applicator. 82 Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. 83 M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqmbut not exceeding 0.11 sqmas in floors over and including 15mm thick screed bedin cement mortar 1:4 set and jointedin neat cement slurry and pointed in coloured cement. complete all as specified and directed 84 S&F for glazed Ceramic tiles 9 to 10 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.. 85 All as per item no. 84 here in before but on vertical surfaces as in skirting etc over and including 10mm thick screed bed in CM 1:3, set and jointed in white cement with pigment to match all as specified and directed. 86 M&L glazed ceramic coloured tiles in vertical surface600x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 10mm thick in CM (1:3) complete allas specified & directed. 87 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc incl brushing neat cement slurry with 3.0kg of cement per sqmtr complete all as specified and directed. 88 M&L for Granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms with necessary hole for gas pipe where ever required and likes over and including cement mortar bedding of 20 mm thick in CM 1:4 including pointing in white cement using marble dust with admixture of pigment to match including rounded edges with shade of granite complete all as specified and directed. 89 M&L for machine cut kota stone slab flooring, and (one Pieces) as in tread, riser, landing, 20-25 mm thick over and including cement screed bed 20mm thick in CM 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. 90 M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part ofsand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete all as specified and directed Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer).(c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. 91 M&L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water.All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint complete all as specified and directed. 92 Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially providedincluding removal of rubbish out side complex (MOD land), complete all as specified and directed 93 M&L for 75 mm thick cement concrete 1:3:6type C2(using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished even and smooth without using extra cement, complete all as specified and directed 94 M&L for 40 mm thick cement concrete 1:2:4type B0(using 12.5mm graded stone aggregate) as in floor & surfaces finished even and fairusing extra cement, complete all as specified and directed 95 Demolition of reinforced cement concrete in any position complete all as specified and directed 96 M&L for precast cement concrete 1:2:4 type B-0 (using 12.5mm stone crushed graded aggregate) as in louvers and jallies 25mm thick designed as fort pattern (measured solid) including all moulding but exceeding frame and set in CM1:4 all as per sample shown complete all as specified and directed 97 M&L for reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone crushed aggregate) as in roof slabs, slab supported on walls, cooking platform, beams and columns, in floors roofs, landings, balconies, canopies and in chajjas, parapet, shelves and the like complete all as specified and directed. 98 Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed. 99 S&F TMTmild steel bars of 10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed. 100 Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortar of any diameter including bends complete all as specified and directed . 101 S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears ,110mm bore complete all as specified and directed . 102 S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, soil, waste, vent pipe in any length with or without ears 75 mm bore complete all as specified and directed 103 S&F for PVC (SWR) bends & tee any radius, 110 mm bore complete all as specified and directed. 104 S&F for PVC (SWR) bends & tee any radius, 75 mm bore complete all as specified and directed. 105 S&F for PVC (SWR) door plates , Yjunction 110 mm bore complete all as specified and directed. 106 S&F for PVC (SWR) door plates ,T junction 110 mm bore complete all as specified and directed. 107 S&F for 100 PVC (SWR) bends with door plate& teecomplete all as specified anddirected. 108 S&F for 75 mm PVC (SWR) bends with door plate & tee complete all as specified anddirected. 109 S&F for 75 mm bore PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in solvent cement concrete complete all as specified anddirected. 110 S&F in repair 20 mm nominal dia and minimum thickness 1.2mm of SS-304 Grade of Stainless Steel tubefor curtain rod including pair of suitable S.S brackets approved by GE including taking down old pelmet boxes with curtain rods complete all as specified and directed. 111 Dismantling wrought iron or mild steel work of any description not otherwise provided for parapet railing, balconies, tank staging, metre rooms shaft areaany descriptioncompleteas specified and directed. 112 Supply and fix welded steel wire fabric(MS Jali) fixed to steel members weight n. exc. 4 kg/sqm including welding complete all as specified and directed. 113 S&F rolled sections as in main and cross beams, hip and jack rafters; purlins , pillars, trusses , water tank stage , framed guard bars, barred iron doors, ladders, frame balusters, walk ways, railing and similar work where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed 114 Dismentling asbestos cement corrugated orsemi corrugated sheets in roof fixed with L hook or cranked bolt complete all as specified and directed 115 S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge 116 S&F in repairs two legged aluminium floor door stopper with rubber shoe 140mm long complerte all as specified and directed by Engineer-in-Charge. 117 ROAD, PATH AND CULVERT 118 Demolition of cement concrete (un-reinforced) in any floor n.exc 15cm thickness ( below or above ground level ) not otherwise specially providedincluding removal of rubbish out side complex (MOD land), complete all as specified and directed 119 M&Lfor 75 mm thick PCCtype D-2 1:4:8 (40mm graded aggreate) as sub-base complete all as specified and directed 120 S&F Endura colour paving tiles 30cm X 30cm x 15-20mm double charged digital printed with gloss, polished matt finished jointed and pointed in neat cement slurry in floors over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. 121 M&L for Providing PCC in coping type B-1, 1:2:4 using 12.5mm graded stone aggregate complete all as specified including necessary form work and finishing the exposed surface even and smoth with using extra cement complete all as specified and directed 122 M&L for broken stone boulders of hard core of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed 123 SEWAGE DISPOSAL 124 Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loosesoil complete all as specified and directed 125 Returningfilling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed 126 Removing excavated materials to a distance exc 1.50 Km but not exc 5 Km outside defence land and depositing where directed complete all as specified and directed 127 M&L for PCC 1 : 4 : 8 type D2 using 40mm graded stone crushed aggregates as in foundation of manholes, posts etc completeall as specified and directed. 128 M&L for PCC 1 : 2 : 4 type B1 using 20mm graded stone crushed aggregates as in surfaces channels and drains complete all as specified and directed. 129 Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stoped ends etc complete all as specified and directed. 130 S&F DWCPE(SN8) 150mm dia (Internal Dia)pipes, snap fit coupler and rubber ring including testing and laid and properly jointed laid in trenches to a level on concrete bed complete all as specified and directed. 131 Demolition of brick work built in cement orcement lime mortar of any description including quoins,arches,pillars,etc., complete all as specified & directed 132 M&L for Brick work with sub class ‘B’ bricks straight or curved on plan, built in cement mortar 1:4 using old size bricks complete all as specified and directed. 133 All as per item no 130 here-in-above but except bricks 134 M&L for PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Itemwater troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed. 135 M&L for precast factory made manhole cover, area of each cover n.exc 0.60 Sqm, 100mm thick with SFRCconcretingincluding grove and hook arrangement for lifting and placing in position and sides covered by MS sheet complete all as specified and directed. 136 Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100mm internal dia pipe, complete all as specified. 137 M&L for rendering 15mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound @ 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately. 138 Demolition and breaking up drain pipes (glazed stone ware, AC or reinforced concrete),150 mm diapipe of any description and in any position set and jointed in cement mortar complete all as specified and directed by Engr-in-Charge 139 INTERNAL ELECTRIFICATION 140 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc 141 Taking down old MCCB , TPN DBs , SPN DBs (incl MCB SPN & SP) & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed. 142 Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. 143 Disconnecting elect connection and taking down of ceiling fan/ Exhaust fanof any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge. 144 M&L for point wiring complete with 1.5 Sqm single core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit of 20 mm nominal diaand conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and including provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel concealed in walls, with modular sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, complete all as specified and directed for the following:- 145 One light /Ceiling fan/exhaust fan point controlled by one switch. 146 One light point controlled by two, two way switch ( switch to be measured and paid separtely) 147 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. 148 One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board 149 One bell point controlled by one bell push. 150 All as per item Ser No 142 here-in-before but point wiring with 2.5 sqmm single core FRLS 1100 Volts in New PVC concealed conduitmedium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 2.5 sqmm single core FRLS 1100 Volts copper conductor cableas earth continuityconnected to common earthfor one 15 A switch socket power point, complete all as specified and directed 151 M&L for submain wiring 4 Sqmm nominal cross sectional area,two single core, 1100 Volts grade, multi-stranded, PVC insulated unsheathed, FRLSHcopper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of suitable dia, medium grade with all conduit accessories and connected to common earth dolly to suitable copper lugs including all cutting/chases etc in walls and making good to the disturbed surfaces to match the existingsurfaces.Note:- Three run of single core wire andone run of conduit shall be measured and paid as one unit complete all as specified and directed 152 All as per item ser No 144 here-in-before but for 02 x 6 Sqmm for phase & neutral and 01 x 6 Sqmm for continuousearth wire concealed/surface 153 M&L for switch Modular type 6 Amp one wayISI marked complete all as specified and directed. Make : Legrand Cat Part No 573400 / Schnider Cat No X1001WH / Wipro Cat No RF 110 154 M&L for switch Modular type 6 Amptwo wayISI marked complete all as specified and directed. Make : Legrand Cat Part No 2573402/ Schnider Cat No X1002WH/Wipro Cat No RF 210 155 M&L for switch Modular type type 16 Ampone way,ISI marked complete all as specified and directedMake : Legrand Cat Part No 573410/ Schnider Cat No X11001WH/Wipro Cat No RF 130 156 M&L for Modular type socket outlet 2 in 1, 5 pin 6 Amp ,ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573424/ /Schnider Cat No X2005WHNS/Wipro Cat No R 1212 157 M&L for Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified and directed. Make : Legrand Cat Part No 573471/ Schnider Cat No X2106WH/ Wipro Cat No R 1332P 158 M&L for ceiling rose 3 phase PVCpolycorbonate,isolated body, complete all as specified and directed 159 M&L for bell push,modular type, 6 Amp, 1 moduleISI marked complete all as specified and directed.Make : Legrand Cat Part No 573413/ Schnider Cat No X1005WH/ equivalent in Wipro 160 M&L for bell ding dong AC, 230 volts, single pole complete all as specified and directed. 161 M&L for angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete all as specified anddirected. 162 S&F LED bulb 12 watts, 1200 lumens output, 6500K suitable for B-22 base complete all as specified and directed. 163 M&L for earthing complete with GIelectrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earthplate not less than 1.50 mtr below normal ground level connected to GI wire 4.0 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze drilled and screwed all as specified including excavation and earth work and disposal of surplus soil incl 15 mm GI tubing light grade and necessary fitting for protection of GI wire incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MSangle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised wire and protection light grade GI pipe upto 7.5 mtr, excavation, etc shall be deemed to be in the quoted rates. 164 S&F sheet metal enclosure distribution board confirmingto IEC - 61439-3, single pole and neutral, AC 240 volts, 08 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make) 165 S&F sheet metal enclosure distribution board confirmingto IEC - 61439-3, single pole and neutral, AC 240 volts, 12 way witn 100 Amps rated copper bus bar and metal double door with IP-43 & IK 09protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete ( Note - MCB & DB shall be of same make) 166 S&FMCB confirming to ISI/IEC -60898-1 (2002), SPN, AC, 240 volts, of 40Amps capacityB curve, 10 kA breaking capacity & making connection by using using suitable copper lugs complete all as specified and directed. 167 S&FMCB confirming to ISI/IEC -60898-1 (2002), SP, AC, 240 volts, of 6-32Amps capacityB curve, 10 kA breaking capacity & making connection by using using suitable copper lugs complete all as specified and directed. 168 Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 120 Lumens/watt andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. 169 S&F in replacement of LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.90, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 140 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. 170 M&L for in replacement Decorative wall mounting CITY-1 Decorative wall light fixture made up of Polycarbonate,Power Factor > 0.90 voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 110 Including 12 W retrofit LED BULB (B-22 base). NOTE- one piece of LED bulb 12 watts included with city -1 fitting complete all as specified and directed. 171 Supply and fix in replacement 10 watts bulkhead fitting, IK 09 with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover,including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. 172 Taking down existing electric meter & refixing the same after completion of job with electric connection by 8 way DB in good way by cleaning and qtr No. marking complete all as specified and directed.. 173 Supply and fixingexhaust fansmetal body AC single phase 230/240 V of size300 mm sweep, Air flow rate > 900cum/min, Bird screen forprotectionagainst birds, double ball bearing, metal body with louvre also with louvre for fixing of exhaust fan complete all as specified and directed. 174 Supply and fixing new BLDC fan against old ceiling fans BLDC conversionthree blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5star rating for energy saving, rated Air delivery >220 cum/min,AC single phase 230/240 V of size 1200 mm sweep including fan regulators,down rod, canopy & all accessories including making connection with three core flexible, copper winding in fan,copper cable pvc insulated of suitable length, complete all as specified and directed. NoteBLDC Fan should work onelectronic fan regulator & also with remote controled. 175 S&F modular type sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall complete all as specified and directed. 176 S&F of water heater storage type Geyser vertical type with suitable size of fastner and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity including provision and connecting up of SS braidedpipe with adopter for inlet and outlet wwater connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity25 Ltrs, having heating element 1.5 KW and not less than 5 star rating,suitable for ,230 volt,50 Hz electric supply complete all as specified and directed . 177 S&F fresh air fan PVC body air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed. 178 S&F in replacement pressure die cast aluminium housing LED street light luminaires with IP-66 deg. of protection suitable for 35 watt LED fitting, Power Factor > 0.90 voltage range - 140 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficency at luminaire level > 110 duly fixed on 25 mm dia GI pipe light grade including 40 X 6 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting complete all as specified and directed. Note : Quoted rates shall be inclusive of all accessories like suitable GI pipe, 40x6 mm thick MS flat, fastner, nut & bolts, suitable length of flexiable wire etc. 179 S&F in repair factory made epoxy powder coated Distribution Board VTPN-4 ways (IP-43 protection), mechanical impactstrength IK - 09, with cement spill protector double doorfabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one MCCB 125/160 Amp as incomer and12 Nos of SP MCB 10 to 63 Amps outgoing and conforming to HSN code : 8537 complete all as specified and directed. Note :- MCCB & MCB will be measured & paid separately. 180 S&F in replacement MCCB 125 Amps, thermal magnetic release,4 pole 16 kA ICS=ICU Complete all as specified and directed.
Contract Date: May 30, 2026 Contract Value : 3.02 Crore
Statutory Bodies & Commissions/Committees No of Bidders 11
19.
Public Administrative Department #11198050 AOC
Annual Plan-Anthikad BP 2025-26 : Renovation of Alappad CHC-Pro.no.65-General Civil Work-- 1 MAINTENANCE 2 15.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 3 21.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 4 21.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) 5 21.2.2:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 6 15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 7 15.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar 8 15.13.1:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below 9 OD185135/2025-2026:Supplying and fixing Pressed Steel Windows and Ventilators of standard pattern with frames (with steel shutter) as per profile of sections 82*62mm, 12mm dia. rod, 25*5mm flat with 75mm MS hinges, 50mm MS hook, 125mm MS stay and handle for windows with section 105*60mm without steel shutters, made of sections 75*30mm for outer styles and horizontal members and then inserted with enclosed and stiffened sheet 26CR with zinc chromate primer.( Data derived for 150*150 cms panelled window) 10 10.29.1:Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides 11 15.23.2:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm 12 8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 13 11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete 14 OD185137/2025-2026:Supplying and fixing Stainless steel floor trap including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 15 50.17.1.3:Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. 16 50.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 17 15.28.2:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet 18 15.28.1:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet 19 10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 20 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 21 OD185139/2025-2026:Roofing with G.I hard colouur powder coated traffod sheets 0.35 mm thick or nearest available thickness with overlaps of 150 mm at ends and GI hook or crank C.I. bolts and nuts including plain washers and bitumen washers etc complete 22 OD243391/2025-2026:Providing & fixing Poly carbonate plain sheet 2mm thick as approved by the Engineer incharge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDMseal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost ofpurlins, rafters, trusses, and including cutting to size and shapes where ever required 23 OD187993/2025-2026:Plain G I ridge capping 225 mm flaps with 0.35mm thick /nearest available size SS screws including plain washers plain washers and bitumen washers etc. complete 24 OD185134/2025-2026:Supplying and fixing 150 mm dia half cut section with brackets at the ends of sheet or tiled roof for rain water collection including all cost of material etc . 25 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) 26 OD185136/2025-2026:welder for welding works 27 10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 28 OD185143/2025-2026:Engaging man coolies 29 50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2 30 50.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 31 50.18.8.7.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2 32 50.18.9.17.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 33 50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 34 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow 35 50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee 36 50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 37 OD185175/2025-2026:Supplying and fixing 20mm thick ready made PVC door (75*200cm) with frame 50*42 mm including conveyance,cost of fitting , labour for fixing etc. 38 OD185176/2025-2026:supply of 20mm PVC Tap 39 OD185177/2025-2026:Carpenter For repairng Doors & WIndows 40 OD198066/2025-2026:Taking out existing interlocking paver blocks , including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in Charge.(Modified data 16.83) 41 OD198218/2025-2026:Laying cement concrete interlocking paver blockover50 mm thick compacted bed of 6mm aggregate , filling the joints with fine sand etc all complete as per the direction of Engineer-in- charge. modified data 16.68 (departmental interlock tile) 42 Drain 43 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 44 4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 45 OD198111/2025-2026:Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 <br>II. P.C.C grade M 15 <br> (i) Nominal mix (1:2.5:5) 46 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 47 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 48 5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 49 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 50 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal sizederived from natural sources) 51 Compound wall 52 15.10.2:Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually / by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge:In cement mortar 53 15.7.1:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar 54 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 55 OD198662/2025-2026:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc complete as per direction of Departmental officers at site 56 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) 57 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 58 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete 59 50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 60 13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). 61 13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Contract Date: Jun 01, 2026 Contract Value : 21.15 Lakh
Government Departments No of Bidders 1
20.
Defence #11192596 AOC
Tender For Provn Of Central Mi Room At Nimu; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 43 2 Lump sum price worked out by the contractor for (SITE CLEARANCE, EXCAVATION & EARTH WORK)as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 44 3 Lump sum price worked out by the contractor for (INTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 50 4 Lump sum price worked out by the contractor for (INTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 52 5 Lump sum price worked out by the contractor for (ROAD, PATH & HARDSTANDING)as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 54 6 Lump sum price worked out by the contractor for (SEWAGE DISPOSAL)as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 55 7 Lump sum price worked out by the contractor for (AREA DRAINAGE)as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 56 8 Lump sum price worked out by the contractor for (SHED FOR DG SET)as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 58 9 Lump sum price worked out by the contractor for (HOT WATER SUPPLY)as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 59 10 Lump sum price worked out by the contractor for (EXTERNAL ELECTRIFICATION)as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 65 11 Lump sum price worked out by the contractor for (EXTERNAL WATER SUPPLY)as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 66 12 SCH A PART - XII (MISC B/R & E/M ITEMS) (REFER BOQ)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 INTERNAL ELECTRIFICATIONS&F Double door three phase prewired distribution board vertical DB VTPN 8 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA.(Note:- Single Phase MCBs are to be measured and paid for seperately) 14 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge.NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 15 S&F new wall mounted fan of approved make and type complete all as specified and as directed. 16 S&F TV Co-axial socket 1 module, complete all as specified and as directed. 17 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps 18 INTERNAL WATER SUPPLYS&F single piece Vitreous china wash down water closet pan Pedestal Pattern white, with seat white closed pattern with flat bottom and cover mild steel chromium plated or aluminized hinging deviced including flushing system , pipe and joint etc and connection to drain, flushing, pipe, anti-syphonage pipe, and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs complete all as spd & directed complete all as specified and directed by Engr-in charge.. 19 S&F CP Grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) dia of outlet is 100 mm complete all as specified and directed by Engr-in charge. 20 S&F hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hookcomplete all as specified Make: Cera, Jaquar , Marc & Hindware as per Sample and directed by Engr -in Charge 21 S&F Soap dish (S/S), any type, fixed to plugs with chromium plated brass screws, all as specified and directed by Engr-in charge. 22 ROAD, PATH & HARD STANDINGM&L for wet mix macadam (WMM) for 150mm thick (compacted thickness) laid in two layers of 75mm each grading as per table 400-13 of MoRTH (Ministry of Road Transport & Highways) specification of Road and Bridge works 2013. Manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and conslidating required gradient and camber. The finished surface tolerance to be as per table 900-1 of MoRTH specification for road and bridge works 2013 complete all as specified and directed by Engr-in-Charge. 23 M&L for applying thermoplastic paint marking 2.5mm thick centerline ,stop line,dashes,arrows etc and n exc 10cm wide on roads pavements with hot applied thermoplastic road marking paint ofapproved colour confirming to BS 3262-1989 with special applicater machine all as per manufacturers instructionof any colour on road surfaceincluding cleaning with gunny bags removing all loose dirt/dust complete all as specified and directed. 24 M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users. 25 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M Dia and 3 M Depth. 26 EXTERNAL ELECTRIC SUPPLYS&F Polycarbonate junction boxes IP 65 protection of size 0.200 x 0.250 x 0.155 m complete with 1 Nos MCB SP 2.5 Amp & 4 way industrial connector including clamp made out of MS flat 30x5mm connection from junction box to street light fitting with three single core PVC insulated, PVC sheathed wire 2.5 Sqmm copper & PVC conduit 20 mm dia complete all as specified and directed by Engr-in-charge. 27 Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge. 28 S&FHT/LT MS cable route indicator 4 dia fixed with two Nos of nut, bolt and washers and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.018 cum in each at base buried under the groundincl necessary earth work complete all as specified and directed by Engr-in-charge. 29 Supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoortype, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheetduly powder coated and shall be CPRI Approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, glands, AI bus bar duly covered with heat shrink sleeves colour coaded duly fixed onDMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm sizeMS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of AGE (I) Nimu to sent the site requirementcomplete all as specified and directed including comprising of following :- 30 (a) MCCB 400 Amps, FP, 36 KA, 415 volts, 50Hz - 01 No (I/C)(b) MCCB 200 Amps, FP, 25 KA, 415 volts, 50Hz - 02 No ( CHS)(c) MCCB 125 Amps, FP, 16 KA, 415 volts, 50Hz - 04 Nos (APFC, TPN DB -02, Spare )(d) MCB SPN 40 Amps, 10 KA, 220 volts, 50Hz - 03 Nos (Garage,Street light, Spare-1)(e) On load Chengeover 400 Amps 4 pole -01 No (f)Digital voltmeter, with VSS - 01set(g) Digital Ammeter, with CTs & ASS - 01 set(h) LED phase indication lamps RYB - 01 set(j)Single phase Rotary Automatic Light controller Nature switch with voltage range 120-440V,AC,20 Amps,IP-65,50HZ-01 Nos(k) Copper bus bar TPN 600 Amps rating - 01 set 31 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 32 EXTERNAL WATER SUPPLYM&Lfor cutting existing GI pipes and insertion of new Tee branches of suitable size to take branch connection of 50mm dia PP-R.Note : Suitable size of Tee branch is deemed to be included in the quoted rate. 33 Construction of stone masonary valve pit chamber of size 90cm x 90 cm x 90 cm (internal dimension) including all necessary excavation and earthwork in hard / dense soil and disposal of surplus soil to a distance not exceeding 50 meters & deposting the same as directed includingPCC in foundation of the mixture (1:4:8) D-2 stone masonary in cement motor 1:4 rendering 15mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externally as the work proceeds in the same mortar as of stone masonary including mild steelframe (made out ofangle in 40x40x6mm) MS steel cover 3.15 mm thick with handle and locking arrangement with ginges angle iron flat as requiredat site including painting of all posed MS work with two coat of synthetic enamel paint over a coat of red oxide primer and painting all the steel surfaces embedded in PCC with two coats of black bituminuos paint andall other relevant work complete . 34 M&L for providing tracer/anti freezing cable of capacity 20W/m required to keep the pipe warm upto avoiding freezing all as specified including electrical wiring cable for connection of suitable size 35 (CENTRAL HEATING SYSTEM)Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 50 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 36 Notes:- (i) Allneccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(ii) The prices should include lifting, shifting and positioning of units at Site.(iii) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer.(iv) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity conforming to relevant IS Code(v) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 37 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with IE3 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below:The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 38 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM. (ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) Pressure gauges 150 mm dia -03 Nos (iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation) (v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation).Pump capacity are as under:Capacityand pump headnot less than flow 25 USGPM , Head 20 mtr (Refernce Model No. : Armstrong : Series 4300 - 40-150 - 2p - 1.5 kW) each including the Triple duty valve and End Suction guide. 39 EXPANSION TANK and Pressurisation Unit:Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 . The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 500 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). Electrical by pass starter for pump setas recommended by OEM. 40 Expansion Tank of 500 Lts capacity 41 PRESSURIZATION UNIT: for Pump Set -03 Nos with Control Panel and accessories. 42 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 550 litres complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 43 Supply, Installation, Testing and Commissioning ofSteel plate Radiator( Wall Mounted) confirming EN- 442 , working pressurerange from 10-13 bar having workinh temparture of 110°C, complete with top grill side cover as standard along with inlet ,outlet valve, Air purge valve andwith threaded plug, flow regulator as per OEM.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 75 Degree Celcius , OUTLET TEMP: 65 Degree Celcius. Referemcwe Model Series. 44 1.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 45 2.5 kW, Type: 33- DKEK, Length is 1000 mm and Height is 600 mm of Radiator. 46 3.5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 600 mm of Radiator. 47 5 kW,Type: 33- DKEK, Length is 1600 mm and Height is 900 mm of Radiator. 48 5 kW,Type: 33- DKEK, Length is 2000 mm and Height is 600 mm of Radiator 49 M & L for Pre-insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 50 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 51 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 52 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 53 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 54 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 55 Buried under ground/Exposed to Ambient:80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 56 Cabel Tray :-Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders as per IS code including bolts & nuts, painting suspenders etc. as required of size 150 mm width X 50 mm depth X 1.6 mm thickness 57 Supplying, fixing, testing and commissioning of following diameter valves (PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 58 80 mm dia Butterfly Valve 59 65 mm dia Butterfly Valve 60 50 mm dia Butterfly Valve 61 Supplying, fixing, testing and commissioning of Y-STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified of size 50 mm dia Y strainer. 62 Supplying, fixing, testing and commissioning of NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified of size 50 mm dia NRV. 63 Supplying, fixing, testing and commissioning of Automatic Air Purge Valves forhot water circulation headeras specified of size Automtic Air Purge Valve 20 mm dia. 64 Supplying, fixing, testing and commissioning of Air Separator compleate allas specified of size 50 mm dia. 65 Supplying, fixing, testing and commissioning of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 66 Supplying, fixing, testing and commissioning of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 67 Electrical distribution Panel Supply, installation, commissioning and testing of factory made, CHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- 68 INCOMERS(i) Bus Bar TPN Al extensible type main bus bars of minimum of 600 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(ii)MCCB 400 Amps, 415 Volt, 36 KA, 4 Pole,Microprocessor release- 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers ) Make: Legrand/Schenider/SimensOUTGOINGS(i) 3Nos- 125A ,25 KA TPNMCCB/ACBwith Microprocessor release (3# Hot Water Generator)(ii) MCB 10 Amp,TPN,10KA, C curve - 06, 3 Nos for Pumps , 2 Nos for Pumps ,01 Nos for glycol transfer pump(iii) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set (iv) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(v) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing for approval of panel to GE before execution. 69 LT CABLES : Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed AI conductor armoured cable/unarmoured as required of 1.1 KV grade complete as require (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray)Note for 49.01 to 49.04 :- Cable shal withstand temperature variation (-) 35 °C to (+) 35 °C at appx 3500 mtr above sea level. 70 3.5 Core x 70 sq.mm. (Electric Hot Water Generator) 71 4.0 Core x 10 sq.mm. (Pump) and (Pressurization Unit) 72 2 Core x 10 sq.mm. (Pump) 73 2 Core x 6 sq.mm (Pressurization Unit) 74 Earthing complete with Copperearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including Copper strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge 75 S&F rubber matting conforming to IS-15652-2006 complete as required. of size2m x 1m x 25 mm 76 Glycol - Water SolutionSupplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 45 : 55 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. (Glycol 45 % ,Water 55 %) 77 For CHS 78 Supply of Gycol for running of Plant for 12 months 79 GLYCOL CIRCULATING PUMP: Supply, Erection, Testing and Commissioning ofTransfer pumps for the capacity of 5 LPM 5 meter head for Glycol Fluidtransfer with base frame foundation, bolts coupling coupling guard,TEFC, (OEM design HP for the required Flowand Head ) andother accessories for proper function of the pump. 80 OXYGEN GAS MANIFOLD : Supply , installation , testing and commission 4+4 oxygen manifold with middle frame, tail pipe, NRV and ESSAB make 10x14 regulator complete all as specified and directed by Engr in charge . 81 Supply, installation , testing and commission 3 cylinder emergency inlet for oxygen complete all as specified and directed by Engr in charge . 82 Supply , installation , testing and commission automatic control panel with Analog Display 02 for oxygen complete all as specified and directed by Engr in charge. 83 S&F of copper tubing of size 15 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 84 S&F of copper tubing of size 12 mm OD, EN -13348 Grade , 0.9 mm wall thickness including proper saddling , clamping and insertion of branches connections including all fitting for medical use, complete all as specified and directed by Engr in charge. 85 S&F BS type gas outle with probe for oxygen for medical compleate all as specified and directed by Engr in charge 86 S&F 1/2 Brass ball valve with end fittings including all fittings for medical usecomplete all as specified and directed by Engr in charge. 87 S&F BPC flow meter (0-15 LPM) including humidfire bottle complete all as specified and directed by Engr in charge . 88 S&F 3/8 Brass ball valveincluding all fittings for complete all as specified and directed by Engr in charge. 89 STAND BY DG SET : Supply,install, test and commissioning of silent Diesel Engine Generating set 415 volts, 3 phase, 4 wireengine as per IS08528 conforming to CPCB Norms IV, and alternator as per IS08528 of capacity 400 KVA at NTP with control panel having meters, sound proof canopy etc with foundation (As per OEM design) including all accessories as per manufactures standard and as per the details given below and independent relay panel for automatic on mains failure:- AC Generator should be suitable for ambient conditions at nimu Leh area. 90 (A) Alternator : Standard design alternator rated at 400 KVA (320KW)net output at power factor 0.8, AC, 3 phase 4 wire, 415 V, 50 Cycles/Second, 1500 RPM self excited, self regulated, screen protected, drip proof IP 23 enclosure, brush less design, voltage regulation ± 2.5 % rated voltage from no load to full load and frequency regulation within ± 1.5 % tolerence. (B)DIESEL ENGINE : Vertical diesel engine of suitable capacity, closed circuit as per BS-649 or IS-1002 direct injection type, Electric starting system having rated speed 1500 RPM. The DG set Shall be capable for running with 10% over loading for 01 hour in every 12 hours as perBS-5514/BS-649. Engine shall be multi cylinder, multi stroke, direct injection andequipped with all standard fitting as per manufactures recommendations and mounted on common base frame with following Specifications.(a) Fly wheel with housing (i) Common base frame of sturdy design suitable for anti vibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions (b) Cooling system (i) Radiator with fan & belts & guard, rubber hoses and thermostat. (ii) Cooling water pump centrifugal type . 91 (c) GOVERNER : Electronic Governer (d) ELECTRIC STARTING SYSTEM : Electric Self starter , 24 volts DC(12 volt, 150 AH battery 2 Nos)charging alternatoraspermanufacturers design,copper leads with lugs of adequate size complete with initial charging of maintenance free battery 2X12 volt 150 AH capacity. (e) GENERATOR MONITORING PANEL : Comprising of following :- (i) Microprocessor based genset controller for metering, monitoring, governing and protection. (ii) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (iii) Alternator protection parameters like under voltage, over current, under frequency, over frequency (alarm & shut down) (f) ACCESSORIES:AVM Pads built or separately mounted to manufacturer base frames. (g) COUPLING ARRANGEMENTS: Fixed coupling, flywheel to suit fixed coupling and fly wheel housing.(h) EXHAUST SYSTEM : should have equipped with emission control device as per latest Govt norms. Silencer complete with exhaust pipe of suitable size upto and out side the building all covered with asbestos rope of suitable size all as specified and as directed.(j) FUEL TANK: Daily service fuel tank of capacity suitable for 8 hours continuous operation made out of 3 mm thick (heat retardant) sheet with indicating gauge, built inside the acoustic enclosures or as per manufacturers design 92 (C)ACOUSTIC ENCLOSURE : All as per CPCB norms IV and OEM of DG Sets design.(D)AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body,dust and vermin proofmade up of CRCA sheet painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers andmounted on floor with PCC pedestal pillars with a clearance of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:-(i) Microprocessor based Panel -01 No(ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for genset (iv) Suitable rating isolating switch MCCB for both DG & main supply.(v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.(vii)Set of indicaters : - (a)Low lube oil pressure (b) DG Set over load(viii) Push button to start, stop (ix) Mode selector switch i.e Auto/Manual/Test/ OFF.(x) Set of Instrument fuse (xi)Set of aluminium bus bar of 600 Amps capacity 3 ph, 4 Wire system (xii) Automatic battery charging unit with DC voltmeter, Ammeter and selector switch for trickle/ Boost charging.(xiii) By Pass arrangement of main supply when AMF circuit fail due to any fault with provision of suitable rating change overs and switches. 93 The following items are deemed to be included in the rate quoted for all DG sets:- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department. (ii)The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(iv) One set of latest Spare part catalogue with price, exploded view of parts and users manual are deemed to be included in the quoted rate.(v) All civil works including foundation for DGSet as per manufacturers drawing/ specification, foundation for AMF panel shall deemed to be included in the quoted rate.(vi) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level.
Contract Date: May 29, 2026 Contract Value : 5.74 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
21.
Educational and Research Institute #11191898 Price Bid
Tender for Civil Work , 2.1.1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth But Exceeding 1.5M In Width As Well As 10 Sqm On Plan Including Disposal Of Excavated Earth Up To 50 M And Lift Up To 1.5 M, Disposed Soil To Be Levelled And Neatly Dressed:All Kinds Of Soil , 2.8.1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil , 4.1.8 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 60.7.1 Dry Rubble Masonry _ Dry Rubble Without Concrete Levelling Course Masonry With Good Quality Blasted Rubble Including Packing To Compactness To Lines And Levels Cost And Conveyance Of All Materials Labour Charges Etc. Complete As Per Direction Of Departmental Officers At Site Ne , 2.25 Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. , 5.1.2 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.9.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.5 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 5.9.6 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts , 5.9.3 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.7 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Stairs, (Excluding Landings ) Except Spiral - Staircases) , 5.22.6 Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or Moree , 5.2.2 Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.3 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , 5.9.16.1 Centering And Shuttering Including Strutting, Etc. And Removal Of Form For: Edges Of Slabs And Breaks In Floors And Wallsunder 20 Cm Wide , 50.6.1.8 Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x15cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level With Thickness 15Cm In: Cm 1:6 ( 1 Cement : 6 Coarse Sand Etc Complete , 22.5 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 13.1.1 12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) , 50.13.1 9 Mm Cement Plastering Of Mix : 1:3 (1 Cement : 3 Fine Sand ) Including All Cost Of Materials, Labour Charges Etc Complete , 9.48.1 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Steel Windows By Welding , 11.49.2 Providing And Laying Vitrified Tiles In Floor With Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints (Payment For Grouting Of Joints To Be Made Separately).Size Of Tiles 600X600 Mm , 11.46.2 Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm , 8.31 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.20.1 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand).Light Shade Pigment Using White Cement , 10.28 Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.) , 5.30 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To Reinforced Cement Concrete Projections. , 21.1.1.2 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.1.2.2 For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) , 21.2.2 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre- Laminated Particle Board With Decorative Lamination On Both Sides , 21.3.1 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) , 9.117.1 Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below (Tolerance ±1 Mm), With Wall Thickness 2.0Mm (±0.2 Mm), Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size 19 X 19 Mm And 1 Mm (± 0.1 Mm) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per Manufacturers Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 48X40 Mm , 9.118.2 Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride (Pvc) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Decorative Moulding Edging On One Side. The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised/Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm (± 0.2 Mm) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic/Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , 10.5.2 Providing And Fixing 1 Mm Thick M.S. Sheet Door With Frame Of 40X40x6 Mm Angle Iron And 3 Mm M.S. Gusset Plates At The Junctions And Corners, All Necessary Fittings Complete, Including Applying A Priming Coat Of Approved Steel Primer.Using Flats 30X6 Mm For Diagonal Braces And Central Cross Piece , 22.23.2 Providing And Applying Integral Crystalline Slurry Of Hydrophilic In Nature For Waterproofing Treatment To The Reinforced Cement Concrete Structures Like Retaining Walls Of The Basement, Water Tanks, Roof Slabs, Podiums, Reservior, Sewage & Water Treatment Plant, Tunnels / Subway And Bridge Deck Etc., Prepared By Mixing In The Ratio Of 5 : 2 (5 Parts Integral Crystalline Slurry : 2 Parts Water) For Vertical Surfaces And 3 : 1 (3 Parts Integral Crystalline Slurry : 1 Part Water) For Horizontal Surfaces And Applying The Same From Negative (Internal) Side With The Help Of Synthetic Fiber Brush. The Material Shall Meet The Requirements As Specified In Aci-212-3R-2010 I.E By Reducing Permeability Of Concrete By More Than 90% Compared With Control Concrete As Per Din 1048 And Resistant To 16 Bar Hydrostatic Pressure On Negative Side. The Crystalline Slurry Shall Be Capable Of Self-Healing Of Cracks Up To A Width Of 0.50Mm. The Work Shall Be Carried Out All Complete As Per Specification And The Direction Of The Engineerin Charge. The Product Performance Shall Carry Guarantee For 10 Years Against Any Leakage.For Horizontal Surface One Coat @1.10 Kg Per Sqm. , 13.26 Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete , 13.48.1 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Two Or More Coats Applied On Walls @ 1.25 Ltr/10 Sqm Over And Including One Coat Of Special Primer Applied @ 0.75 Ltr /10 Sqm , 13.48.3 Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications:Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/10 Sqm Of Approved Brand And Manufacture , 16.68 Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M - 30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Od398633/2025-2026 Supplying And Fixing Steel Pressed Single Panelled Door Of Size 120*205Cm With Steel Frames Using Superior Quality Gi Sections Made Of Tata Steel , Od398630/2025-2026 Providing And Fixing Roller Blinds Curtains Using Good Quality Materials, Fitted To The Wall With Necessary Fittings. All Complete As Per Direction Of Engineer In-Charge , Od398632/2025-2026 Providing And Fixing Of Acrylic Name Board With Printed Acrylic Board .All Work As Per The Direction Of Engineer In Charge , Od398631/2025-2026 Supply And Fixing Of Name Board Of Size 3.60*0.60M Made Of Acp Panels Supported Over Gi Frame Work , Furnishing Work , Od398627/2025-2026 Providing And Fixing Staff Table Of Size 2.00X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete.. , Od398625/2025-2026 Providing And Fixing Staff Table Of Size 1.80X0.70X0.75M Made With Marine Plywood 18Mm Thick Over Fixing 3Mm Thick Teakwood Veneer, 1Mm Thick Mica Lamination On Inside And Providing One Draw ,One Cupboard,Key Board Including All Other Fittings All Cost Of Materials All Labour Charges Etc Complete. , Od398626/2025-2026 Providing And Supplying Staff Revolving Chair , Od398629/2025-2026 Supplying High Back Executive Chair Nylon Base Multi-Function Mechanism, With Cushion And Leather Finish, Including Transporting Charges And All Other Loading And Handling Charges. , Od398628/2025-2026 Supplying Of Public / Waiting Seating: Three Seater. ( 35 Kg - Gw ) Gauge : 14 &Rdquo;, Dimension: 173Cm * 64Cm * 89Cm. Seat Dimension : 43Cm * 51Cm * 49Cm. Seat &Amp; Back: 1.5Mm Perforated Powder Coated. Beam: 2.0Mm Mild Steel Powder Coated , Od398624/2025-2026 Supply Of Godrej Steel Shelf Of Size 1.00 X 0.50 X2.10M, 16 Gauge , Made Of Good Quality Sheet Applying Suitable Paints All Complete As Per The Direction Of Engineer-In Charge , Plumbing And Sanitary Fittings , 17.3.1 Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type) With Seat And Lid, 10 Litre Low Level White Vitreous China Flushing Cistern & C.P. Flush Bend With Fittings & C.I. Brackets, 40 Mm Flush Bend, Overflow Arrangement With Specials Of Standard Make And Mosquito Proof Coupling Of Approved Municipal Design Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required :W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , 18.48 Providing And Placing On Terrace (At All Floor Levels) Polyethylene Water Storage Tank :Isi 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. , 50.17.1.5 Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.3 Supplying And Fixing Cp Towel Rod 60Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In Charge. , 50.17.1.1 Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 17.7.8 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Including Operated Levers , 50.18.9.9.1 Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 , 50.18.9.22.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement- 110 Mm Dia Bend. , 50.18.9.22.5 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement 110X110x110 Mm Dia Tee , 50.18.9.13.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 12 Kgf/ Cm2- External Work- Exposed On Wall Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.14.1 Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mml Dia 10 Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.17.1 Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clip At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 63 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall , 50.18.9.20.4 Providing And Fixing Pvc Moulded Fittings/ Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 63 Mm Dia Bendl , 50.18.9.20.5 Providing And Fixing Pvc Moulded Fittings/Accessories For Rigid Pvc Pipes Including Jointing With Pvc Solvent Cement - 63X63x63 Mm Dia Tee , 18.54.4 Providing And Fixing Ptmt Bib Cock Of Approved Quality And Colour.15 Mm Nominal Bore, 90 Mm Long, Weighing Not Less Than 93 Gms , Electrical Works , 90.1.1.1 Supply And Laying Medium Gauge Pvc Conduit Of The Following Sizes Conforming To Is 9537/1983 Part Iii In Roof Slab, Jointing The Pipes With Pvc Solvent Cement, Tying & Fixing The Conduit Firmly With The Re-Inforcement Etc. As Required.20 Mm , 90.2.2.1 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point With 6A, Plate Ceiling Rose - Short Point , 1.10.2 Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mmfrls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B , 90.2.2.3 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Light Point Without Ceiling Rose - Short Point , 90.2.2.4 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Single Control Ceiling Fan Point With 6 A, 3 Plate Ceiling Rose & With Socket Size Stepped Electronic Regulator. - Short Point , 90.2.2.5 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Call Bell Point With 6 A Bell Push At One End And 6 A, 3 Plate Ceiling Rose At Other End - Short Point , 90.2.2.6 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Combined Plug Point With 6 A, 5 Pin Plug Socket Controlled By 6 A Switch In The Same Switch Board As That Of Light Points , 90.2.2.7 Supply And Wiring Points According To Is 732-1989 Through The Existing Conduit With 1.00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade, Including Providing Switch Board Main And Continuous Earthing With No.14 Swg Bare Copper,Required Quantity Of Copper Earth Socket, Brass Bolt And Nut Crimping/ Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes, Modular Type Front Plates (White) Etc. Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall, Colour Washing Etc. Complete. All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties, Tie Mounts Etc As Required. (Group B/ Rohs Compliant Modular Accessories).Independent Plug - Short Points , 90.3.18.2 Supply, Fabrication, Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size, Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer, Making Good The Damages, Colour Washing Etc As Required.32 Mm Dia With Hg Company Fabricated Clamps , 90.4.5.4 Supply, Installation, Testing And Commissioning Of Ceiling Fan Of Following Sizes Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. 1200Mm Sweep - Ceiling Fan Complete With Service Value Minimum 4.0(Cub Meter/Minute/Watt), Air Delivery Minimum 210(Cubic Meter/Minute), Copper Winding Suitable For 230V/240V Single Phase Ac Supply , 90.5.1.3 Supply And Fixing The Following Types Of Superior Quality 250V A.C Call Bell On Existing M.S. Box And Giving Connections With Required Length Of 3 Core, 16 / 0.20Mm 650/1100V Grade Pvc Insulated And Pvc Sheathed Round Copper Conductor Flex Wire Conforming To Relevant Iss Or With The Extended Original Wiring, Earthing The Ms Box And Making Good The Surface As Required.Ding Dong Bell , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 90.10.3.15 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )32A Dp Switch With Indicator) , 90.10.3.14 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A Sp Switch With Indicator , 90.10.3.32 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3 Pin Plug Top With Indicator , 90.10.3.33 Supply And Fixing The Following Modular Switches & Accessories In The Existing Front Plates And Giving Necessary Connections As Required (Rohs Compliant )25A 3Pin Shuttered Socket , 90.15.4.2 Supply Conveyance, Installation, Testing And Commissioning Of 36/40W Led Street Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing,Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , 90.16.1.3 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.1.1 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required2.00 Mm Copper Conductor ( 14 Swg) , 90.16.5.3 Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , 2.3.1 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 6 Way, Double Door , 2.3.4 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 16 Way, Double Door , 2.10.1 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , 2.10.3 Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Double Pole , 2.12.1 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Commissioning Etc. As Required. 40 Amps Amps , 2.14.2 Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And , 1.17.2 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 1.5 Sq. Mm , 1.17.4 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 1.5 Sq. Mm , 1.17.11 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 2.5 Sq. Mm , 1.17.13 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 2.5 Sq. Mm , 1.17.20 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 4 Sq. Mm , 1.17.29 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.2 X 6 Sq. Mm , 1.24.3 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 annual periodical maintenance Switch , 1.24.5 Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 annual periodical maintenance Socket Outlet , 1.26 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , 1.27.2 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.56 Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5/6 A Modular Socket Outlets And 2 Nos. 5/6 A Modular Switches, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). , 1.58 Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. , Od398610/2025-2026 Supply ,Installation Of 32 A Kit Cat Fuse Unit Made By Porcelain/ Ceramic , Od398618/2025-2026 Providing And Fixing Of Service Pipe (32 Mm) , Od398612/2025-2026 Supply And Fixing 200Mm Plastic Shade On Existing Batten/Angle/Pendant/Bracket Fittings As Required , Od398615/2025-2026 Supply And Fixing 9 W Led Bulb On Existing Lamp Holder B22 , Od398613/2025-2026 Supply And Providing Suitable Iron Hook Grouted On The Ceiling For Hooking The Ceiling Fan , Od398622/2025-2026 Supply, Conveyance, Installation, Testing And Commissioning Of The Following Sizes Of Exhaust Fans In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of 24/0.20Mm Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Iss. -200 Mm, Single Phase Light Duty Exhaust Fan In Plastic Frame ( Light Duty Exhaust Fan) , Od398616/2025-2026 Fabrication, Supply And Installation Of Wall Mounting Powder Coated Open Type Gi Meter Box Of Following Size Suitable For Fixing Single Phase Energy Meter, Kit Cat Fuse, Neutral Link Etc. Hinged Door Construction, Knock Out For Cable Entry Etc. As Required , 90.6.6.2 Supply And Drawing Frls Pvc Insulated & Sheathed 650/1100 V Grade 3 Core Copper Conductor Flat Cable For Submersible Pump Motor Conforming To Is 694 Part I 1990 As Required Including Giving Necessary Connections Of The Following Sizes.2.50 Sq Mm , Od398614/2025-2026 Supply Installation Testing And Commissioning Of Single Phase Dol Starters For 0.25 To 3 Hp Motor , Od398617/2025-2026 Supply Installation Testing And Commissioning Of Water Purifier Wit The Following Specifications (12 L Ro + Uv + Tds + Controller) , Od398619/2025-2026 Supply Installation Testing And Commissioning Of Iso / Bis Certified Igbt Technology Based 2.5Kv Online Ups/Inverter With Minimum 3 Years On-Site Waaranty And Having The Following Minimum Specifications. 1. Output:230V+1% 50Hz Sine Wave Single Phase. 2. Input: 170V To 270V Hz Ac 3. Rating: 2.5Kva, 4. Backup Time: Minimum 2 Hrs, On Full Load, 5. Efficiency: 90% Or Higher. 6. Battery Bank: 150Vah/Above(2Nos) Or Higher Tubular Battery With Minimum 3 Years Warranty With Suitable Battery Rack. 7. Protection: Over Load, Short Circuit, Battery Reverse Polarity, Input Voltage Below Or Above The Specified Range Over Discharge Or Charge Of Battery, Accepted Model: Hykon Or Equivalent Brand With Better Specification. , Od398620/2025-2026 Supply, Conveyance, Installation And Testing Of 80Cm(32 Inch) Hd Ready Led Tv Of The Following Sizesusing Standard Accessories Including And Providing Wall Mounting Stands. Screen Resolution 1366X768- Hd And 2 Hdmi &Amp; 1 Usb Ports, Working On 230V/240V Single Phase A/C As Required , Od398611/2025-2026 Supply And Installation Of Set Top Box , Od398623/2025-2026 Earthing With G.I. Earth Pipe 2.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. ( But With Charcoal/ Coke And Salt) As Required , Od398621/2025-2026 Supply &Amp; Installation Of 1200Mm, 20W Led Tube And Giving Connections With Required Length Of 16/0.20Mm 3 Core Copper Conductor Flex Wire . , Network Wiring And Installation , 90.6.10.1 Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , 1.27.1 Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module (75Mmx75mm) , 1.53.1 Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Od398643/2025-2026 Providing And Fixing Of 16-Port Gigabit Unmanaged Switch.( D-Link Dgs-1016A Or Equivalent ) , Od398639/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398644/2025-2026 Supply Installation Testing And Commissioning Of Following Sizes Of Wall Mount Network Rack. 4U 350D( But Without Server, Switches Cooling Fans Etc.) , Od398636/2025-2026 Supply Installation Testing And Commissioning Of Cat6 Utp 24-Port Network Panel Desktop 19-Inch Rack Integration Server Mounting Shielded.24 Port Laded Patch Panel (D-Link Or Equivalent) As Required. , Od398634/2025-2026 Supply Installation Testing And Commissioning Of Wireless Ac1200, Dual-Band And Ceiling Mount Gigabit Access Point (Tp-Link Eap225 Ac1200 Wireless Mu-Mimo Gigabit Indoor/Outdoor Access Point/ Equivalent) , Od398637/2025-2026 Supply And Stackingg Of Cat-6 Patch Cord -2M , Od398640/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable-1Mtr , Od398642/2025-2026 Supply And Stacking Of Cat-6 Patch Cord Cable- 0.5 Mtr , Od398641/2025-2026 Supply, Conveyance, Installation And Testing Of Cooling Fan For Incubator, Fan For Computer Server 120 * 120 * 38Mm, 4.7 Inch Black , Od398638/2025-2026 Supply And Fixing/Crimping Modular Cat6 Rj45 Data Socket On The Existing Modular Plate Or Patch Panel.(Rj 45 Data Socket Without Face Plate) , Od398635/2025-2026 Supply Conveyance And Installation Of Poe Injector. (Tenda Te-Poe30g-At Gigabit Poe Injector Or Equivalent) N
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
22.
Agriculture #11175867 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Clearing And Grubbing Road Land Clearing And Grubbing Road Land Including Uprooting Wild Vegetation, Grass, Bushes, Shrubs, Saplings And Trees Of Girth Upto 300 Mm, Removal Of Stumps Of Such Trees Cut Earlier And Disposal Of Unserviceable Materials And Stacking Of Serviceable Material To Be Used Or Auctioned, Upto A Lead Of 1000 M Including Removal And Disposal Of Top Organic Soil Not Exceeding 150 Mm In Thickness As Per Morth Specification Clause 201. By Mechanical Means In Area Of Thorny Jungle , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 50 M As Per Morth Specification Clause 305.3 , Carriage Of Earth, Sand, Lime, Morrum Manure Or Sludge For 5 Km. , Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. , Dismantling Stone Slab/ Terrazo Chip Flooring Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. , Carriage Of Building Rubbish Stone Metal (Grit And Ballast Etc.) Up To 50 Mtr Lead , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786) Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Providing And Laying Damp-Proof Course With Cement Concrete Grade M-150 (1 : 2 : 4) Mortar Prepared With 1% Solution Of Water-Proof Compound Complete As Per Specification 50Mm Thick. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Random Rubble Dry Stone Kharanja Under Floor. , Supply And Installation Of Multi Rib Proofing/Cladding Sheet Manufacture Out Of 0.50Mm Tct (Total Coated Thickness) High Tensile Zinc Aluminum Alloy Coated Galvalume Steel (As Per 150Gsm Zinc Aluminum Coated 550Mpa Tuekd Strength) Confirming To Is: 1397/Astm A-792 Sheet To Have Wide Pens 30Mm High Nb At 250 Centre And Centre Width Of 1020Mm Sheets Be Casted With Regular Modified Polyster System On A Continuous With Line On Centre For Face And With A Polyster Coating Respectively Sheet Shall Have Proportionality With Siphoned Plate Made To Prevent Leakage Sheet Shall Be Fixed By More Of Sell Drilling Lift Tapping Hot Dip Zinc Coated Hox Head Fasterner Of Size 12X14x55mm Long. The Sheet Shall Be Supplied In Cost One Length And For A Minimum Up To 12Mts With All Scaffolding. , Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu /Jalore (Red/Choclate/Black/ Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joints Etc. Complete Fine Finish : 12 Mm Thick . , Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) , Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged : Style/Rail Of Teak Wood 30Mm Thick/ Aluminium Section 4Wide , Renewing Glass Panes And Refixing Existing Wooden Fillets : 5Mm Thick Plain Glass Panes. , Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge Window Openable. , Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Making Khurras 450 X 450Mm With Average Minimum Thickness 50Mm Cement Concrete 1 : 2:4 Over P.V.C. Sheet 1 Mtr. X 1 Mtr. X 40Micron Finished With 12Mm Cement Plaster 1 : 3 And One Coat Of Neat Cement, Rounding Edges And Making And Finishing The Out Let Complete. , Providing Corrugated G.S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete (Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Whenever Required. 0.80 Mm Thick With Zinc Coating Not Less Than 275 Gm/M2 , Providing And Fixing Welded Mesh/Expanded Metal Mesh In Frame Work, Flat Iron Beading 20X3mm Including Top Cross Laps Inside And Out Sides Welding, Iron Bolts, Crews, Clips Etc. Complete (Excluding Frame Work) Of Size. Welded Mesh 25 Mmx 25 Mm X 2.1 Mm , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Charge : Profile B , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing & Fixing Mica Of Approved Make For Inner/Outer Side Of Shutters With Fevicol & Nails Complete As Per Approved By Engineer In Charge. 0.8Mm Thick Mica , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 60 Mm As Per Drawings And As Per Is 15658:2006.And Materials Conforming To Morth Specification Clause 602 With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blocks. Category B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Granular Sub-Base With Close Graded Material (Table:- 400-1) Plant Mix Method Providing Laying Spreading And Compacting Specified Graded Sand, Gravel (Crushed Stone) As Per Table 400-1,400-2 Or Any Other Course Material As Per Design Mix, As Per Cbr In Sub Base Course Including Premixing The Material At Omc In Wet Mix Plant, Carriage Of Mixed Material Spreading In Uniform Layers With Motor Grader F.E Loader On A Prepared Base And Compacting With Vibratory Roller To Achieve Desired Density (As Per I.S.2720) Including All Material, Labor, Machinery, Lighting Guarding, Barricading And Maintenance Of Diversion Complete.[Morth Specification : Clause 401]. By Mechanical Means. For Grading-Iii Material , Dry Lean Cement Concrete Sub - Base. Construction Of Dry Lean Cement Concrete Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg/ Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Providing And Laying Water Proofing Treatment On Roofs Of Slabs By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : , After Surface Preparation, First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. , Laying Second Layer Of Fiber Glass Cloth When The First Layer Is Still Green . Overlaps Of Joints Of Fiber Cloth Should Not Be Less Than 10 Cm . , Third Layer Of 1.5 Mm Thickness Consisting Of Slurry Of Cement @ 1.289 Kg/Sqm Mixed With Water Proffing Cement Compound @ 0.670 Kg/Sqm And Coarse Sand @ 1.289 Kg/Sqm. This Will Be Allowed To Air Cure For 4 Hours Followed By Water Curing For 48 Hours. The Entire Treatment Will Be Taken Upto 30Cm On Parapet Wall And Tucked Into Groove In Parapet All Around , Fourth And Final Layer Of Brick Tiling ‘With Cement Mortar Or Any Other Approved Protective Coarse. (Which Will Be Paid For Separately) For The Purpose Of Measurement The Entire Treated Surface Will Be Measured , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Old Work (One Or More Coats ) , Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , One Or More Coats On Old Work. , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: Old Work (One Or More Coats). , Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Prepartion Of Base With Sand Papering, Primer, Putty, Etc Complete In All Respect Including Scaffolding And Safety Provision New Work , Old Work , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead : For Thickness Of Tiles 10Mm To 25Mm. , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. 1: 3: 6 Or Richer Mix. , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately). , For Fixed Portion Anodised Aluminum (Anodised Transparent 81 Dyed To Required Shade According To Is : 1868. (Minimum Anodic Coating Of Grade Ac 15, Anodizing To Be Got Done From Approved Anodizer) , For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Anodised Aluminum (Anodised Transparent 81 Dyed To Required Shade According To Is : 1868. (Minimum Anodic Coating Of Grade Ac 15, Anodizing To Be Got Done From Approved Anodizer) , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs/Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge. (Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.) With Glass Panes Of 4.0 Mm Thickness ( Weight Not Less Than 10.0 Kg/Sqm) As Per Is : 2835. , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge. Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , P & F Soap Dish Or Tray Of Approved Quality/Make C.P. Brass , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : Size 580 Mm X 450 Mm , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : Size 630 Mm X 500 Mm Dia For Counter Top , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make :450 Mm , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P & F Kitchen & Lab. Sink Of Approved Make With C.I. Brackets Duly Painted, 40 Mm C.P. Waste Coupling, C.P. Brass Chain With Rubber Plug, 40 Mm G.I. Waste Pipe Up-To Floor Level Complete Including Cutting And Making Good The Wall & Floor : 1.0 Mm Thick Stainless Steel Aisi -304 & Is 13983-1994 Kitchen Sink Of Approved Make As Per Engineer-In-Charge With Large Waste Coupling. 45 X 20 X 8 20X16x8 (With Drain Board) , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- , Size 230 X110 X150 Cm.(For 20 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F Grating Of Approved Quality/Make: Stainless Steel Sheet Size 125Mm Dia. Heavy Quality Of Approved Make , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) 20Mm Nominal Size , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20Mm Nominal Size , 25 Mm Nominal Size , 32Mm Nominal Size , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: C.P. Brass Bib Cock,15Mm Nominal Bore. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings, This Included Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement , Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. (External Work). , 25 Mm Nominal Size , 32Mm Nominal Size , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: , Coupler (Socket) , 110Mm Dia , Plain Tee , 110Mm Dia , Bend 87 .5 , 110Mm Dia , Pipe Clip , 110Mm Dia , Providing And Fixing Superior Quality Pvc Tank Cover Complete As Per Approved By Engineer In Charge , Above 500 Lt. Capacity , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: , 1000 Ltr. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete : Solid Pvc (Is 2548 Marked) Grade-I White For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend As Per Is : 7231 . , Providing And Fixing Unplasticized Poly Vinyl Chloride (Upvc) Swr Pipes Type B For Sciland Waste Discharge System (Is:13592 : 1992 Marked) Of Approved Quality /Make 110 Mm Dia , Providing And Fixing Unplasticized Poly Vinyl Chloride (Upvc) Swr Pipes Fittings Type B For Sciland Waste Discharge System (Is:13592 : 1992 Marked) Of Approved Quality /Make 110Mm Dia , Coupler , Bend 87.5 Dg. , Bend 45 Dg. , Door Bend 87.5 Dg. , Single Tee , Vent Cowel
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
23.
Tourism #11175186 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation In Trenches For All Leads & Lifts In All Type Of Strata Comprising Of Any Type Of Materials Either In Full Or Part As The Case May Be Adopting Any Method/Methods As May Be Convenient As Permitted Excluding Blasting In All Conditions Such As Dry, Moist, Foul, Saturated, Submerged, Etc,. Including Dressing Of Sides, Planking & Strutting, Timbering ,Ramming Of Bottom ,Pumping And Bailing Out Water ,Barricading Danger Lighting Guarding, Getting Out Excavated Soil & Stacking As Directed By Engineer For All Leads & Lifts Etc. Complete , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Supplying And Filling In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. Moorum , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level. M-30 Grade Of Concrete , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. I.Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc.String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing : In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Providing And Fixing Exposed Laterite Stone Of 100 Mm Thk For Dado ,Laid On Cement Mortar Paste 1:4 (1 Cement : 4 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Stone Including Rubbing Including Applying Acrylic Varnish Etc Complete. As Per Designs And The Directions Of The Engineer-In-Charge. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Vitrified Floor Tiles In Different Sizes Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make In Colours And Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigment Etc., Complete. 600X 600 Mm Dark Shades , Providing And Laying Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Lakha Red , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid . Plain White Makrana Slab 25Mm Thick , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : White Makrana Marble , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete). , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 30 Cm Lx 40 Cm H X 15 Cm T , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Steel Bars & Disposal Of Unserviceable Within 50 , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. 12 Mm Cement Plaster 1 :3 ( 1 Cement : 3 Sand) , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws, Plugs And Priming Coat On Unexposed Surfaces Etc. 50 X 12 Mm , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 250 X 16X 5Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Providing And Fixing 150 Mm. Bright Finished Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutter Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete , Providing And Applying Decorative Plastering For A Window Sorrounding, Using 1:4 Morter Mixture With Bricks Chips,Featuring A 300Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer. (The Job Involves Applying A Decorative Finish Over Underlying Structure, Incorporation Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Double Piller At The Corner (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center For Hall(Ht 2.10 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 200Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Arch Of Span Of 3Mt., Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering Ofr Cornice At Ceiling In Hall Of Ht 0.40Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Construction And Installation 6Mt Height Replica Of Shree Suptakoteswar Stumb Using Sadhahalli Grey Granite Stone With Intricate Carvings, Moulding As Per Drawing. The Structure Should Have 6Mt Ht. With 2.5 X2.5X0.70 Mt Ht At Base And Stumb Of 1.50X1.50X5.25 Mt Height At Top As Per Details Drawings And Direction By The Engineer. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A 150Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Padma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Cornice ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Adhopadma For Sajja), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Electrical Works , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 1/2 Core 70Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 1.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 2.5 Sq.Mm , Supply Of 4 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core 2.5 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(A) In Soily Strata , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 70 Sq. Mm. , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(K) 12 Way (8+36), Double Door, Horizontal Type Cat B , Supplying And Fixing 40 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group C -- With Cat B Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.(C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.A) 20 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.B) 25 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Requiredd) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Requireda) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredb) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(C) 6 Module (200Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredsitc Of Wall Fan,600 Mm Sweep, With All Accessories. , Supply Installation Testing And Commissioning Of 8-10 W Spot Light Cob Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supply Installation Testing And Commissioning Of W 80W Flood Light Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =600X1500(H),Lamp Base- G9, Wattage- 7X42w Max, Complete With All Accessories. , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =1200X1500(H),Lamp Base- G9, Wattage- 12X42w Max, Complete With All Accessories. , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineerincharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement(Plumbing Will Be Paid Seperately). , Supply Installation Testing and Commissioning of 12W Multi Color Spot Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Wall Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 12W, Cct : Rgbw, (As Per The Design Approval) Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik05, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik05, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 400Mm. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Linear Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 80W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo Separate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik07, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of High Quality Multi Color Neon Flexible Light, Protection Rating : Ip65, Mounting Structure : Adjustable Wall Mount Ss Clips For Fixing The Lights. Power Consumption : 12W, Cct : Rgb/Rgbw, (As Per The Design Approval) Beam Angle : 120º, Control : Dmx512 Channel : 4 Ch, Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Time Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Epistar, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights Having The Rotation Degrees Embosed In The Die Cast. Power Consumption : 50W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik08, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of Aluminium Profile For Neon Flex , Supply Installation Testing and Commissioning of Dc Power Driver For The Above Lights, Power : 200W, Input : Ac 110-240V Ac, 50Hz, Output : Dc 12/24V, Protection Rating, Ip67, Surge Protection : Ll 4Kv, Le 6Kv , Supply Installation Testing and Commissioning of High Quality Dmx Decoder, Power Input : Dc 24V , Supply Installation Testing and Commissioning of Pvc Insulated Multi Core Electrical Un Armoured Flexible 5C X 0.5Sq Mm Power Cable Having Less Electrical Losses. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 5 Core Dmx Cable Comprises Twisted Pairs With Shield Support For Carrying Of Data. Dmx512 Cable Is Used For Connecting All Light Consoles That Use Dmx 512 Standard Data Transmission. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete For Both Power And Dmx. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of Ip65 I Power Connectors Having 3/4 Pole Cable Connector, Chuck Type Strain Relief, Current Rating 20 A Rms Continuous, Easy And Extremely Precise Locking System Quick Lock High Impact Materials - Long-Lasting And Reliable , Supply Installation Testing and Commissioning of Ip65 I Dmx Connectors Having 3/5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Male Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Female Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of Power Distribution Board Made Up Of Ms Sheet Metal Fabricated Housing Black Powder Coated And Ivery Connectors For The Internal Terminations And External Outgoing Connecting Points, Fibre / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. Timer With Required Contactor For Auto Switching. Power Panel Suitable For Indoor/Outdoor Applicable And Floor Mount / Wall Mount Options. - 12 Nos Of 6/10A Sp Outgoing Mcbs. - 1No Of 32A Tpn Incoming Mcb. , Supply Installation Testing and Commissioning of Ip Driver Box Made Up Of Pvc / Upvc And Ivory Connectors For The Internal Terminations And External Outgoing Connecting Points, Fiber / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. , Supply Installation Testing and Commissioning of Dmx Isolator Or Splitter Provides Isolated Optical Dmx Splitter Provides 8 Outputs From A 1 Input And Input Voltage: Ac 110 To 220 V, 50 Hz, Product Features: Group 1 & Group 8 Dmx Signal Change. , Supply Installation Testing and Commissioning of Din Rail Mount Dmx Controller Can Be Used To Control A Wide Variety Of Different Dmx Systems- From Rgb/Rgbw To More Advanced Moving And Color Mixing Luminaires, Dmx Audio Players And Fountains. The Controller Comes With A Variety Of Features, Iphone/Ipad/Android Remote Control, Wi-Fi Facilities, Dry Contact Port Triggering And Flash Memory.Usb Connection • 1024 Dmx Channels Universe In Live Mode (Computer) • 8 Dry Contact Trigger Ports Via He10 Connector • Stand Alone Mode With 5 Area And 90+ Scenes, Mac Osx 10.6/10.7/10.8 - Windows Xp/Vista/Seven/8 32/64 Bits And Usb 2.0, Xlr3, Mini Usb, 1 He10, Power From 5V To 5.5V Dc (Ac/Dc Adapter In Option. , Supply Installation Testing and Commissioning of Programming Charges , Supply Installation Testing and Commissioning of Additional Accessories For Installing The Lights As Per The Final Drawing/Site Condition Consisting Of Clamps, Brackets, Angles, Conduits, Joints, Hardwares Like Fasteners, Nut & Bolts Etc., , Street Light Panel: Supply, Installation, Testing And Commissioning Of Lt Panel Ip- 67 Outdoor Type,Floor Mounted Panel, Shall Be Suitable For 415 V, 3 Phase, 4 Wire, 50Hz Supply System. With 3 Phase Energy Meter And 100A Tpn Mcb As Incommer And 11 Nos Of Tpn Mcb As Outgoing With 3 Numbers Of Microcontoller Based Programmable Digital Almac Timer As Directed By Engineer In-Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
24.
Defence #11167626 AOC
Tender For Repair, Recanning And Polishing Of Wooden Furniture Under Ge Guwahati= 1 Repair To Bed Hard Wooden (Fd 213/212/245/246) 2 Foot Rest : M&L For Removing Unserviceable Foot Rest Portion Of Bed Hard And S & F New Foot Rest 3.5/4Mm Thick One Side Teak Faced And Other Side Commercial Bwr Ply Wood Alongwith Replacement Of Unserviceable Wooden Legs With Well Seasoned 1St Class Teak Wood And Providing Readymade 30X4Mm Teak Wood Beading Complete All As Per Drg (Fd-246) Duly Finished With French Polish To All Wooden Surface Expost To View Complete All As Per Specified And Directed. 3 Head Rest: M&L For Replacement Of Head Rest Of Bed Hard Complete All As Per Specified And Directed. 4 Long Rail: M&L For Replacement Of Unserviceable Long Rail Of Bed Hard And S&F New Long Rail Made Out Of Seasoned Teak Wood Duly Finished Complete All As Per Specified And Directed. 5 Head Board & Foot Board: M&L For Replacement Of Unserviceable Ply Wood From The Head Board And Foot Board Of Bed Hard And S&F Of New Plywood With One Side Teak Faced And Other Side Commercial Bwr To Shape & Size Including Provision Of Teak Wood Beading Of Size 30X4Mm Without Disturbing To The Teak Wood Frame Complete All As Directed. 6 Top: M&L For Replacement Of The Unserviceable Ply Wood Top From Bed Hard S&F New Plywood 12Mm Thick Bwr Plywood 7 Ply Isi Marked Confirming To Is-303 Of Size 1840X910Mm Complete All As Per Drg (Fd-245/246) Or Specified And Directed. (Make : Kitply/Greenply/Century ) Isi Marked. 7 Polishing Complete Removal Of Existing Painting/Polish And Applying Two Coats Of High Gloss Polyurethane Enamel High Gloss Paint Of Approved Make Of By Spray Painting Method Over And Including A Coat Of Pink Primer And Prepration Of Surfaces Complete All As Specified And As Directed All As Per Specified In The Drg (Fd-246) Bed Hard And As Directed. 8 Repair To Book Case, Side Board Fd-241/26(M)/372, Bin Soiled Multipurpose Fd/E6/Map/09 9 Top: M&L For Removing Old Unserviceable Top And S&F Of New Top Made Up Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked Of Size 1220Mm L X 455 Mm W Complete As Shown On Drawing And As Specified. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries 10 Side: M&L For Removing Old Unserviceable Side And S&F Of New Side Made Up Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked Of Size 455Mm W X 635 Mm H Complete As Shown On Drawing And As Specified. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries 11 Bottom: M&L For Removing Old Unserviceable Bottom And S&F Of New Bottom Made Up Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked Of Size 1220Mm L X 455 Mm W Complete As Shown On Drawing And As Specified. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries 12 Drawers: M&L For Removing Old Unserviceable Drawers And S&F Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked 360Mm L X 455 Mm D X 75/140/150/180Mm H And 6 Mm Commercial Plywood 455 Mm D X 360 Mm L At The Base Of Each Drawer Complete As Shown On Drawing And As Specified. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Plywood: -Kitply/Archid Ply/National/Green Ply 13 Leg Frame: M&L For Removing Old Unserviceable Leg Frame And S&F Of 2Nd Class Teak Wood Of Same Size And Shape Duly Finished/Smoothened Complete All As Specified And Shown In Drawing. Make Of Hardwood:- Teak Wood Or Equivalent As Approved. 14 Back: M&L For Removing Old Unserviceable Back And S&F Of New 6 Mm Thick Commercial Bwr Plywood 1220Mm L X 635 H Complete As Specified And Shown On Drawing.Make Of Plywood: -Kitply/Archid Ply/National/Green Ply 15 Cup Board: M&L For Removing Old Unserviceable Shutter Cup Board And S&F Of New Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked 360Mm L X 600 Mm H Shutter. The Shutters Shall Be Provided With 4Mm Thick 2Nd Teak Wood Edging Allround And Each Cupboard To Be To Be Fixed With Hinges Of Approved Quality. The Rest All As Specified And Shown On Drawing.Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood:- Bansum Or Equivalent As Approved. 16 Knob: M&L For Removing Old Unserviceable Knobs And S&F Of New 35Mm Size Knobs Complete As Specified And As Directed. Make:- As Per Sample Approved. 17 Repair To Chair Dining Fd-16(M)/279/228 18 Front Legs: M&L For Removing Old Unserviceable Front Legs Of Chair Dining And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar In Size And Shape Complete As Specified And Shown On Drawing. Pvc White Shoe To Be Provided On Each Leg. Make:- Teak Wood Or Equivalent As Approved. 19 Rear Legs: M&L For Removing Old Unserviceable Rear Legs Of Chair Dining And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing . Pvc White Shoe To Be Provided On Each Leg Make:- Teak Wood Or Equivalent As Approved. 20 Front/Side/Back Rails: M&L For Removing Old Unserviceable Front Rails/Side Rails/Back Rails Of Chair Dining And S&F Of New Rails Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing.Make:- Teak Wood Or Equivalent As Approved. 21 Back Rest: M&L For Removing Old Unserviceable Back Rest Of Chair Dining And S&F Of New One Of Made Out Of 2Nd Class Hard Wood Similar Size And Shape Complete As Specified And Shown On Drawing.Make:- Teak Wood Or Equivalent As Approved. 22 Stiffeners: M&L For Removing Old Unserviceable Back Stiffner Of And S&F Of New One Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing. Make:- Teak Wood Or Equivalent As Approved. 23 Assembling: M&L For Assembling The Repaired Chair Dining And S&F Beads Made Of 2Nd Class Teakwood To The Interior Wall Of The Seat Alongwith Making Holes For Canning As Shown On Drawing And As Directed. Make:- Teak Wood Or Equivalent As Approved. 24 Polishing: M&L For Preparation Of Surface By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface As Specified And As Directed. 25 Repair To Chair Wooden Bottom Without Arms Fd-285 26 Front Legs: M&L For Removing Old Unserviceable Front Legs Of Chair And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar In Size And Shape Complete As Specified And Shown On Drawing. Pvc White Shoe To Be Provided On Each Leg. Make:- Teak Wood Or Equivalent As Approved. 27 Rear Legs: M&L For Removing Old Unserviceable Rear Legs Of Chair And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing . Pvc White Shoe To Be Provided On Each Leg Make:- Teak Wood Or Equivalent As Approved. 28 Front/Side/Back Rails: M&L For Removing Old Unserviceable Front Rails/Side Rails/Back Rails Of Chair And S&F Of New Rails Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing.Make:- Teak Wood Or Equivalent As Approved. 29 Back Rest: M&L For Removing Old Unserviceable Back Rest Of Chair And S&F Of New One Of Made Out Of 2Nd Class Hard Wood Similar Size And Shape Complete As Specified And Shown On Drawing.Make:- Teak Wood Or Equivalent As Approved. 30 Stiffeners: M&L For Removing Old Unserviceable Back Stiffner And S&F Of New One Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing. Make:- Teak Wood Or Equivalent As Approved. 31 Seat: M&L For Removing The Old Unserviceable Seat Of Chair & S&F Of New Seat Of Same Size Made Of 12 Mm Plywood Complete As Specified And As Directed. 32 Polishing: M&L For Preparation Of Surface By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface As Specified And As Directed. 33 Repair To Chair Dining Offrs With Cushion Seat Map Fd/Map-Ii/04 / Fd/E6/Map/10 34 Front Legs: M&L For Removing Old Unserviceable Front Legs Of Chair Dining With Cushion Seat And S&F Of New Legs Of Made Out Of 2Nd Class Hard Wood Similar Size And Shape Complete As Specified And Shown On Drawing. Pvc White Shoe To Be Provided On Each Leg Make:- Teak Wood Or Equivalent As Approved. 35 Rear Legs: M&L For Removing Old Unserviceable Rear Legs Of Chair Dining With Cushion Seat And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing. Pvc White Shoe To Be Provided On Each Leg Make:- Teak Wood Or Equivalent As Approved. 36 Front /Side / Rear Rails: M&L For Removing Old Unserviceable Front / Side / Real Rails Of Chair Dining With Cushion Seat And S&F Of New Rails Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing.Make:- Teak Wood Or Equivalent As Approved. 37 Back Stiffeners: M&L For Removing Old Unserviceable Back Stiffner Of Chair Dining With Cushion Seat And S&F Of New One Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing. Make:- Teak Wood Or Equivalent As Approved. 38 Tapestry: M&L For Removing Of Old Tapestry And S&F Of New One Of Best Quality Tapestry, Colour Approved By Engr-In-Charge Including Stitching In Size Over Cushion As Specified And Shown On Drawing. Make :- Raymonds/ Dedecor/Bombay Dyeingrate Of Tapestry Cloth To Be Minimum Of Rs 350 /- Per Metre . 39 Cushion: Removing The Exising Worn Out Seat Cushion And Providing New Seat Cushion With 75 Mm Th,32 Density Foam On Seat Of 12Mm Th Ply And Fixing In The Seat For Chair Dining With Cushion Seat (Map) Complete As Specified And Shown In Drawing And As Directed.Make Of Foam :- Kurlon/Sleepwell/Featherlite 40 Polishing: M&L For Preperation Of Surface By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface As Specified And As Directed. Make:- Sheenlac/Shalimar/Godavari Paints 41 Repair To Chair Easy (Fd-17(M) / 229 / 285 42 Front Legs: M&L For Removing Old Unserviceable Front Legs Of Chair Easy And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing. Pvc White Shoe To Be Provided On Each Leg. Make:- Teak Wood Or Equivalent As Approved. 43 Rear Legs: M&L For Removing Old Unserviceable Rear Legs Of Chair Easy And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing . Pvc White Shoe To Be Provided On Each Leg Make:- Teak Wood Or Equivalent As Approved. 44 Hand Rest: M&L For Removing Old Unserviceable Hand Rest Of Chair Easy And S&F Of New One Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing .Make:- Teak Wood Or Equivalent As Approved. 45 Front /Side / Rear Rails: M&L For Removing Old Unserviceable Front / Side / Real Rails Of Chair Easy And S&F Of New Rails Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing.Make:- Teak Wood Or Equivalent As Approved. 46 Top Rails Of Back: M&L For Removing Old Unserviceable Side Rail Of Back Of Chair Easy And S&F Of New One Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing .Make:- Teak Wood Or Equivalent As Approved. 47 Assembling: M&L For Assembling The Repaired Chair Easy And S&F Beads Made Of 2Nd Class Teak Wood To The Interior Wall Of The Seat Alongwith Making Holes For Canning As Shown On Drawing And As Directed. Make:- Teak Wood Or Equivalent As Approved. 48 Polishing: M&L For Preperation Of Surface By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface As Specified And As Directed. Make:- Sheenlac/Shalimar/Godavari Paints 49 Repair To Chair Writing (Fd-20(M) / 250 / 280) 50 Front Legs: M&L For Removing Old Unserviceable Front Legs Of Chair Writing And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing. Pvc White Shoe To Be Provided On Each Leg.Make:- Teak Wood Or Equivalent As Approved. 51 Rear Legs: M&L For Removing Old Unserviceable Rear Legs Of Chair Writing And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing . Pvc White Shoe To Be Provided On Each Leg.Make:- Teak Wood Or Equivalent As Approved. 52 Hand Rest: M&L For Removing Old Unserviceable Hand Rest Of Chair Writing And S&F Of New One Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing .Make:- Teak Wood Or Equivalent As Approved. 53 Front /Side / Rear Rails: M&L For Removing Old Unserviceable Front / Side / Real Rails Of Chair Writing And S&F Of New Rails Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing.Make:- Teak Wood Or Equivalent As Approved. 54 Top Rails Of Back: M&L For Removing Old Unserviceable Side Rail Of Back Of Chair Writing And S&F Of New One Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing .Make:- Teak Wood Or Equivalent As Approved. 55 Assembling: M&L For Assembling The Repaired Chair Writing And S&F Beads Made Of 2Nd Class Teak Wood To The Interior Wall Of The Seat Alongwith Making Holes For Canning As Shown On Drawing And As Directed. Make:- Teak Wood Or Equivalent As Approved. 56 Polishing: M&L For Preperation Of Surface By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface As Specified And As Directed. Make:- Sheenlac/Shalimar/Godavari Paints 57 Recanning All Type Of Wooden Chairs , Stool Dressing, Bin Soiled Linen Etc After Removing The Old Cane And Tightening Of Frames And Weaving With New White Plastic Cane With 1.8Mm Wide Oval Type And 3 Mm Wide Oval Type For Boarder All Along The Frameof Approved Quality Complete As Per Pattern Shown On Drawing And As Specified Fd-279/228/16(M)/ 229/250/280282/244.Note:- Cane Shall Be Of Plastic Strips Of Superior Quality, Type-I (Hdpe) White Or Cream As Directed And Of Uniform Width Confirming To Is-5387 . Make:- Maharasthra Cane /New India Plastic 58 Repair To Peg Table (Fd-25(M) / 227/384) 59 Top: M&L For Removing Old Unserviceable Top Of Peg Table And S&F Of New Top Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked 450Mm L X 300Mm W Complete With 4Mm Thick 2Nd Class Teak Wood Edging All Around As Shown On Drawing And As Directed. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries 60 Leg: M&L For Removing Old Unserviceable Legs Of Peg Table And S&F Of New Legs Made Of 2Nd Class Teak Wood 380Mm Long As Shown On Drawing And As Directed. Pvc White Shoe To Be Provided On Each Leg. Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 61 Long Rail: M&L For Removing Old Unserviceable Long Rails Of Peg Table And S&F Of New Long Rails 450Mm Long Made Of 2Nd Class Teak Wood Of Same Size And Shape Long As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 62 Short Rail: M&L For Removing Old Unserviceable Short Rails Of Peg Table And S&F Of New Short Rails 300Mm Long Made Of 2Nd Class Teak Wood Of Same Size And Shape Long As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 63 Polishing: M&L For Preperation Of Surfaces By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface Of Peg Table All As Shown On Drawing And As Directed. Make:- Sheenlac/Shalimar/ Godavari Paints 64 Repair To Table Dining 6 Persons (Fd-273) 65 Top: M&L For Removing Old Unserviceable Top Of Table Dining 6 Pers 1500Mm X 900Mm And S&F Of New Top Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked Complete With 4Mm Thick 2Nd Class Hardwood Edging All Around As Specified And Shown On Drawing And As Directed.Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Bansum Or Equivalent As Approved. 66 Leg: M&L For Removing Old Unserviceable Legs Of Table Dining 6 Pers 1500Mm X 900Mm And S&F Of New Legs Made Of 2Nd Class Teak Wood 760Mm Height 75Mm X 40Mm As Shown On Drawing And As Directed. Pvc White Shoe To Be Provided On Each Leg. Make:-Teak Wood Or Equivalent As Approved. 67 Long Rail: M&L For Removing Old Unserviceable Long Rails Of Table Dining 6 Pers 1500Mm X 900Mm And S&F Of Long Rails 1500 Mm 25Mm X 100Mm Long Made Of 2Nd Class Teak Wood Of Same Size And Shape Long As Shown On Drawing And As Directed.Make:-Teak Wood Or Equivalent As Approved. 68 Short Rail: M&L For Removing Old Unserviceable Short Rails Of Table Dining 6 Pers 1500Mm X 900Mm And S&F Of Short Rails 900Mm Long 45Mm X 90Mm Long Made Of 2Nd Class Teak Wood Of Same Size And Shape Long As Shown On Drawing And As Directed.Make:-Teak Wood Or Equivalent As Approved. 69 Assembling & Polishing: M&L For Dismantling Old Unserviceable Parts And Reassembling With New Ones Along With Preperation Of Surfaces By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface Of Table Dining 6 Pers 1500Mm X 900Mm All As Shown On Drawing And As Directed. Make:- Sheenlac/Shalimar/ Godavari Paints 70 Repair To Table Dining 8 Persons (Fd-30(M) / 273) 71 Top: M&L For Removing Old Unserviceable Top Of Table Dining 8 Pers 1800Mm X 900Mm And S&F Of New Top Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked Complete With 4Mm Thick 2Nd Class Hardwood Edging All Around As Specified And Shown On Drawing And As Directed. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Bansum Or Equivalent As Approved. 72 Leg: M&L For Removing Old Unserviceable Legs Of Table Dining 8 Pers 1800Mm X 900Mm And S&F Of New Legs Made Of 2Nd Class Teak Wood 760Mm Height 75Mm X 40Mm As Shown On Drawing And As Directed. Pvc White Shoe To Be Provided On Each Leg Make:- Teak Wood Or Equivalent As Approved. 73 Long Rail: M&L For Removing Old Unserviceable Long Rails Of Table Dining 8 Pers 1800Mm X 900Mm And S&F Of Long Rails 1800 Mm 25Mm X 100Mm Long Made Of 2Nd Class Teak Wood Of Same Size And Shape Long As Shown On Drawing And As Directed. Make:-Teak Wood Or Equivalent As Approved. 74 Short Rail: M&L For Removing Old Unserviceable Short Rails Of Table Dining 8 Pers 1800Mm X 900Mm And S&F Of Short Rails 900Mm Long 25Mm X 100Mm Long Made Of 2Nd Class Teak Wood Of Same Size And Shape Long As Shown On Drawing And As Directed. Make:-Teak Wood Or Equivalent As Approved. 75 Assembling & Polishing: M&L For Dismantling Old Unserviceable Parts And Reassembling With New Ones Along With Preperation Of Surfaces By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface Of Table Dining 8 Pers 1800Mm X 900Mm All As Shown On Drawing And As Directed. Make:- Sheenlac/Shalimar/ Godavari Paints 76 Repair To Teapoy (Fd-278/382/232) 600Mm X 450Mm X 540Mm (Fd-278/382/232) 77 Top: M&L For Removing Old Unserviceable Top Of Teapoy 600Mm X 450Mm And S&F Of New Top Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked Complete With 4Mm Thick 2Nd Class Hardwood Edging All Around As Specified And Shown On Drawing And As Directed. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries 78 Leg: M&L For Removing Old Unserviceable Legs Of Teapoy And S&F Of New Legs Made Of 2Nd Class Teak Wood 540Mm Height 60Mm X 30Mm As Shown On Drawing And As Directed. Pvc White Shoe To Be Provided On Each Leg.Make Of Hardwood:- Teak Wood Or Equivalent As Approved. 79 Assembling & Polishing: M&L For Dismantling Old Unserviceable Parts And Reassembling With New Ones Along With Preperation Of Surfaces By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface Of Teapoy All As Shown On Drawing And As Directed. Make:- Sheenlac/Shalimar/ Godavari Paints 80 Repair To Table Bed Side Fd-157(M)/Fd-276 81 Top: M&L For Removing Old Unserviceable Top Of Table Bed Side And S&F Of New Top Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked Complete As Specified And Shown On Drawing And As Directed. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries 82 Side: M&L For Removing Old Unserviceable Side Of Table Bed Side And S&F Of New Side Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked Complete As Specified And Shown On Drawing And As Directed.Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 83 Back: M&L For Removing Old Unserviceable Back Of Table Bed Side And S&F Of New Back Made Of 6 Mm Thick Commercial Bwr Plywood Complete As Specified And Shown On Drawing.Make Of Plywood: -Kitply/Archid Ply/National/Green Ply 84 Polishing: M&L For Preperation Of Surface By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface As Specified And As Directed. Make:- Sheenlac/Shalimar/Godavari Paints 85 Repair To Table Centre Fd-274 (900Mm X 450Mm X 400Mm 86 Top: M&L For Removing Old Unserviceable Top Of Table Centre And S&F Of New Top 900Mm X 450Mm Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked With 4Mm Thick 2Nd Class Hardwood Edging All Around Complete As Specified And Shown On Drawing And As Directed. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 87 Leg: M&L For Removing Old Unserviceable Legs Of Table Centre And S&F Of New Legs Made Of 2Nd Class Teakwood 400Mm Height 60Mm X 30Mm As Shown On Drawing And As Directed. Pvc White Shoe To Be Provided On Each Leg.Make Of Hardwood:- Teak Wood Or Equivalent As Approved. 88 Top Long Rail: M&L For Removing Old Unserviceable Top Long Rails Of Table Centre And S&F Of New Ones Made Of 2Nd Class Teakwood 900Mm Height 20Mm X 50Mm As Shown On Drawing And As Directed. Make Of Hardwood:- Teak Wood Or Equivalent As Approved. 89 Top Short Rail: M&L For Removing Old Unserviceable Top Short Rails Of Table Centre And S&F Of New One Made Of 2Nd Class Teak Wood 450Mm Height 20Mm X 50Mm As Shown On Drawing And As Directed. Make Of Hardwood:- Teak Wood Or Equivalent As Approved. 90 Bottom Long Stiffners: M&L For Removing Old Unserviceable Bottom Long Stiffners Of Table Centre And S&F Of New One Made Of 2Nd Class Teak Wood 900Mm Height 20Mm X 50Mm As Shown On Drawing And As Directed.Make Of Hardwood:- Teak Wood Or Equivalent As Approved. 91 Bottom Short Stiffners: M&L For Removing Old Unserviceable Bottom Short Stiffners Of Table Centre And S&F Of New One Made Of 2Nd Class Teak Wood 900Mm Height 20Mm X 50Mm As Shown On Drawing And As Directed.Make Of Hardwood:- Teak Wood Or Equivalent As Approved. 92 Assembling & Polishing: M&L For Dismantling Old Unserviceable Parts And Reassembling With New Ones Along With Preperation Of Surfaces By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To Old And New Surface Of Table Centre All As Shown On Drawing And As Directed.Make:- Sheenlac/Shalimar/ Godavari Paints 93 Repair To Table Dressing Ladies (Fd-32(M) / 251) 94 Top: M&L For Removing Old Unserviceable Top Of Table Dressing Ladies And S&F Of New Top 900Mm X 380Mm Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked With 4Mm Thick 2Nd Class Hardwood Edging All Around Complete As Specified And Shown On Drawing And As Directed. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 95 Side: M&L For Removing Old Unserviceable Side Of Table Dressing Ladies And S&F Of New Side 300Mm X 380Mm Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked With 4Mm Thick 2Nd Class Hardwood Edging All Around Complete As Specified And Shown On Drawing And As Directed. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 96 Drawer: M&L For Removing Old Unserviceable Drawers Upper And Lower For Table Dressing Ladies And S&F Of New Drawer Made Of 12 Mm Thick Commercial Bwr Plywood 150Mm X 380Mm X 350Mm With 6 Mm Thick Commercial Bwr Plywood At The Base 350Mm X 380Mm Complete As Specified And As Shown On Drawing. Make Of Plywood: -Kitply/Archid Ply/National/Green Ply 97 Leg Frame: M&L For Removing Old Unserviceable Leg Frame Of Table Dressing Ladies And S&F Of 2Nd Class Teak Wood Of Same Size And Shape Duly Finished/Smoothened Complete All As Specified And Shown In Drawing. Pvc White Shoe To Be Provided On Each Leg.Make Of Hardwood:- Teak Wood Or Equivalent As Approved. 98 Mirror: M&L For Removing Old Unserviceable/Broken Mirror (366X1220 Mm) With Frame And S&F Of New Mirror 5Mm Th Electro Copper Plated Mirror Of Polished Sheet Glass Covered On Edges And 6Mm Th Plywood At The Back And Frame Made Of 2Nd Class Teak Wood 45X40 Mm Complete As Specified And As Shown On Drawing. Make:- Saint Gobain / Modiguard 99 Glass Pane: M&L Of Old Unserviceable/ Broken Glass Pane / Shutter Of Table Dressing Ladies And S&F Of New One 5Mm Thick Transparent Type Supported By Alumimium Channel As Specified And As Shown On Drawing.Make:- Saint Gobain / Modiguard 100 Back: M&L For Removing Old Unserviceable Back Of Table Dressing Ladies And S&F Of New Back Made Of 12 Mm Thick Commercial Bwr Plywood 900Mm X 300Mm Complete As Specified And Shown On Drawing. Make Of Plywood: -Kitply/Archid Ply/National/Green Ply 101 Knob: M&L For Removing Old Unserviceable Knobs Of Table Dressing Ladies And S&F Of New 35Mm Size Knobs Complete As Specified And As Directed. Make:- As Per Sample Approved. 102 Repairs To Table Dressing Gents Fd-230 103 Top: M&L For Removing Old Unserviceable Top Of Table Dressing Gents And S&F Of New Top 900Mm X 300Mm Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked With 4Mm Thick 2Nd Class Hardwood Edging All Around Complete As Specified And Shown On Drawing And As Directed. Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 104 Side: M&L For Removing Old Unserviceable Side Of Table Dressing Gents And S&F Of New Side 150Mm X 300Mm Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked With 4Mm Thick 2Nd Class Hardwood Edging All Around Complete As Specified And Shown On Drawing And As Directed.Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 105 Drawer: M&L For Removing Old Unserviceable Drawers Upper And Lower For Table Dressing Gents And S&F Of New Drawer Made Of 12 Mm Thick Commercial Bwr Plywood 300Mm X 300Mm X 150Mm With 6 Mm Thick Commercial Bwr Plywood At The Base 300Mm X 300Mm Complete As Specified And As Shown On Drawing. Make Of Plywood: -Kitply/Archid Ply/National/Green Ply 106 Mirror: M&L For Removing Old Unserviceable/Broken Mirror (380X760Mm) With Frame And S&F Of New Mirror 5Mm Th Electro Copper Plated Mirror Of Polished Sheet Glass Covered On Edges And 6Mm Th Plywood At The Back And Frame Made Of 2Nd Class Teak Wood 35X25 Mm With Rawl Plugs Both At The Top Side For Hanging Complete As Specified And As Shown On Drawing. Make:- Saint Gobain / Modiguard Make For Hardwood:- Teak Wood Or Equivalent As Approved. 107 Back: M&L For Removing Old Unserviceable Back Of Table Dressing Ladies And S&F Of New Back Made Of 12 Mm Thick Commercial Bwr Plywood 900Mm X 150Mm Complete. Metal Clips To Be Provided On Each Repaired Table Dressing Gents For Hanging On The Wall As Specified. Rest As Specified And Shown On Drawing. Make Of Plywood: -Kitply/Archid Ply/National/Green Ply 108 Knob: M&L For Removing Old Unserviceable Knobs Of Table Dressing Ladies And S&F Of New 35Mm Size Knobs Complete As Specified And As Directed. Make:- As Per Sample Approved. 109 Repair To Table Writing (Fd-275) (1145X600X760Mm) 110 Top: M&L For Removing Old Unserviceable Top Of Table Writing And S&F Of New Top 1145Mm X 600Mm Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked With 4Mm Thick 2Nd Class Teak Wood Edging All Around Complete As Specified And Shown On Drawing And As Directed.Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 111 Leg: M&L For Removing Old Unserviceable Legs Of Table Writing And S&F Of New Legs Made Of 2Nd Class Teak Wood 760Mm Height 35Mm X 55Mm As Shown On Drawing And As Directed. Pvc White Shoe To Be Provided On Each Leg.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 112 Top Short Rail: M&L For Removing Old Unserviceable Short Long Rails Of Table Writing And S&F Of New Ones Made Of 2Nd Class Teak Wood 600Mm Length 25Mm X 50Mm As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 113 Top Long Rail: M&L For Removing Old Unserviceable Top Long Rails Of Table Writing And S&F Of New Ones Made Of 2Nd Class Teak Wood 1145Mm Length 25Mm X 50Mm As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 114 Stiffeners Side Bottom: M&L For Removing Old Unserviceable Stiffners Side Bottom Of Table Writing And S&F Of New Ones Made Of 2Nd Class Teak Wood 600Mm Length 25Mm X 50Mm As Shown On Drawing And As Directed. Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 115 Stiffeners Long Bottom: M&L For Removing Old Unserviceable Stiffners Long Bottom Of Table Writing And S&F Of New Ones Made Of 2Nd Class Teak Wood 1145Mm Length 25Mm X 50Mm As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 116 Drawer: M&L For Removing Old Unserviceable Drawers For Table Writing And S&F Of New Drawer Of The Same Shape And Size Made Of 12 Mm Thick Commercial Bwr Plywood With 6 Mm Thick Commercial Bwr Plywood At The Base Complete As Specified And As Shown On Drawing. Make Of Plywood: -Kitply/Archid Ply/ National/Green Ply 117 Cup Board: M&L For Removing Old Unserviceable Cup Board Of Table Writing And S&F Of New One Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked. The Shutters Shall Be Provided With 4Mm Thick 2Nd Hardwood Edging Allround And Each Cupboard To Be Provided With Magnetic Catcher And Cupboards To Be Fixed With Hinges Of Approved Quality. The Rest All As Specified And Shown On Drawing.Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 118 Knob: M&L For Removing Old Unserviceable Knobs Of Table Writing And S&F Of New 35Mm Size Knobs/Handles Complete As Specified And As Directed.Make:- As Per Sample Approved. 119 Polishing: M&L For Preperation Of Surfaces By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To All Surfaces Of Table Writing All As Shown On Drawing And As Directed. Make:- Sheenlac/Shalimar/ Godavari Paints 120 Repair To Sofa Set 4 & 5 Seater With Cushion Fd-281 121 M&L For Supply Of New Tapestry Cloth Cover For 100 Mm Thick Cushions Of Size 560X530Mm For Seat/Back Of Sofa. The Cover Shall Be Provided With Zip Facility (Costof Tapestry Cloth Shall Not Be Less Than Rs. 350/- Per Rm) Of Approved Quality And Shade Duly Stitched As Specified And Directed. (Fd - 281/373) 122 M&L For Supply Of Of New Foam Cushion Of Size 533X560X100Mm Thick, 32 Density For Seat And Back Of Sofa Set 5 Seater & 4 Seater Duly Covered With Inner Cover With New Marking Cloth Superior Quality And New Tapestry Cloth On Top As Outer Cover Zipable Type And Cost Of Tapestry Cloth Not Less That Rs 350/- Per Meter As Approved By Ge Complete All As Per Drg (Fd-281/373) And As Directed. 123 M&L For Removing Old Unserviceable Batten Of Sofa And S&F Of New Batten Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing.Make:- Teak Wood Or Equivalent As Approved.Note : Each Batten Will Be Measured And Paid As One Unit. 124 M&L For Removing Old Unserviceable Rear Legs Of Sofa And S&F Of New Legs Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing. Make:- Teak Wood Or Equivalent As Approved.Note : Each Leg Will Be Measured And Paid As One Unit. 125 M&L For Removing Old Unserviceable Hand Rest Of Sofa And S&F Of New One Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing .Make:- Teak Wood Or Equivalent As Approved.Note : Each Arm Will Be Measured And Paid As One Unit. 126 M&L For Removing Old Unserviceable Front / Side / Real Rails Of Sofa Single Seater And S&F Of New Rails Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing.Make:- Teak Wood Or Equivalent As Approved. 127 M&L For Removing Old Unserviceable Side Rail Of Back Of Sofa Single Seater And S&F Of New One Of Made Out Of 2Nd Class Teak Wood Similar Size And Shape Complete As Specified And Shown On Drawing .Make:- Teak Wood Or Equivalent As Approved. 128 Polishing: M&L For Preperation Of Surfaces By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To All Surfaces Of Sofa Set 4 & 5 Seater With Cushion All As Shown On Drawing And As Directed. Make:- Sheenlac/Shalimar/ Godavari Paintsnote : One Sofa Set Of 5 Seater Will Be Measured As One Unit. Tightening Of Frame Wherever Required Shall Be Deemed To Be Included In The Rate Quoted. 129 Repair To Table 3X2 (900X600X760 Mm) With/ Without Drawer Fd-283/284 130 M&L For Removing Old Unserviceable Top Of Table 3X2 And S&F Of New Top 900Mm X 600Mm Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked With 4Mm Thick 2Nd Class Teak Wood Edging All Around Complete As Specified And Shown On Drawing And As Directed.Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 131 M&L For Removing Old Unserviceable Legs Of Table 3X2 And S&F Of New Legs Made Of 2Nd Class Teak Wood 760Mm Height As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 132 M&L For Removing Old Unserviceable Short Long Rails Of Table 3X2And S&F Of New Ones Made Of 2Nd Class Teak Wood As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 133 M&L For Removing Old Unserviceable Top Long Rails Of Table 3X2 And S&F Of New Ones Made Of 2Nd Class Teak Wood As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 134 M&L For Removing Old Unserviceable Stiffners Side Bottom Of Table 3X2 And S&F Of New Ones Made Of 2Nd Class Teak Wood As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 135 M&L For Removing Old Unserviceable Stiffners Long Bottom Of Table 3X2 And S&F Of New Ones Made Of 2Nd Class Teak Wood As Shown On Drawing And As Directed.Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 136 M&L For Removing Old Unserviceable Drawers For Table 3X2 And S&F Of New Drawer Of The Same Shape And Size Made Of 12 Mm Thick Commercial Bwr Plywood With 6 Mm Thick Commercial Bwr Plywood At The Base Complete As Specified And As Shown On Drawing. Make Of Plywood: -Kitply/Archid Ply/National/Green Ply 137 Polishing: M&L For Preperation Of Surfaces By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To All Surfaces Of Table 3X2 All As Shown On Drawing And As Directed.Make:- Sheenlac/Shalimar/ Godavari Paints 138 Repair To Table 3X3 (900X900X760 Mm) Fd-291 139 M&L For Removing Old Unserviceable Top Of Table 3X3 And S&F Of New Top 900Mm X 900Mm Made Of Pre Laminated Particle Board 18 Mm Exterior Grade Isi Marked With 4Mm Thick 2Nd Class Teak Wood Edging All Around Complete As Specified And Shown On Drawing And As Directed.Make Of Particle Board :- Eco Board/Bhutan Board /Novapan/Green Ply Industries Make Of Hardwood :- Teak Wood Or Equivalent As Approved. 140 Polishing: M&L For Preperation Of Surfaces By Cleaning With Emery Paper To Obtain Clean Surface And Using Putty Where Ever Required And Polishing With Two Coats Of French Polish To All Surfaces Of Table 3X3 All As Shown On Drawing And As Directed. Make:- Sheenlac/Shalimar/ Godavari Paints 141 Repair To Hat Stand With Mirror Fd-361
Contract Date: Jun 30, 2026 Contract Value : 16.93 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 9
25.
Heavy Industries and Public Enterprises #11159621 Technical Bid
Tender For Renovation Of Training Centre At Kcm Plant; 1 Providing & Fixing Precoated galvanised iron profile /Trapezoidal prifile sheets (Size,Shape and pitch of corrugation as approved by Engineer-In-Charge)manufactured out of 0.50 mm (0.05%)TCT with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyster top coating 15-18 micron. Sheets should have protective guard film of 25 microns minimum to avoid scratches during transportation. The sheet shall be fixed using self drilling/self tapping screws size(5.50-8 x55 mm) with EPDM seal, complete upto any pitch in Horizontal/Vertical or curved surfaces, excluding the cost of purlins,rafters & trussesand including cutting to size and shape whenever required. 2 Providing and fiixing precoated galvanised steel sheetsroofing accessories 0.50 mm(+0.50%) total coated thickness , Zinc coating 120 grams per sqm as per IS 277, 240 mpa steel grade , 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns using self drilling/self tapping screws of size ( 5.5-8 x 55 mm with EPDM seal) complete.(A) Ridges plain(500-600 mm). 3 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorptions less than 0.08% andconformingtoIS:15622ofapprovedmakeinallcoloursand shades, laidon 20mm thick cement mortar 1:4 (1 cement: 4coarse sand)includinggroutingthejointswithwhitecementandmatching pigments etc., complete.Size of Tile 60x60 cm 4 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-Charge12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. 5 Providing and fixing aluminium work for doors, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved mark confirming to IS : 733 and IS : 1285 , fixed with dash fastners of required dia and size , including necessary fillings up of gaps at junctions at top, bottom and sides with required EPDM Rubber / Neoprene gasket etc. Aliminium sections shall be smooth rust free straight metred and jointed mechanically wherever required including clit angle aliminium snap beading for glazing / panneling C.P Brass/ stainless steel screws all complete as per architectural drawing and the directions of Engineering In Charge (Glazing ,panneling dash fasteners to be paid for separately). For shutters of doors , windows and ventilators including providing and fixing hinge/pivots and making provision for fixing of fittings wherever required including the cost of EPDM Rubber / Neoprene gasket required (fitting shall be paid for separately) Power coated aluminium (Minimum thickness of powder coating 50 micron). 6 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) 7 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead :With cement mortar 1:4 (1 cement : 4 fine sand) 8 DISMANTLING WOODEN PARTITION WALL INCLUDING FRAME WORK, COMMERCIAL PLY, DOOR SHUTTER WITH BUTT HINGES, WOODEN BEADING ETC. COMPLETE, AS PER DIRECTION OF ENGINEER IN- CHARGE. LABOUR RATE ONLY 9 REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS, ROOFS HAVING SLOPE UPTO 15 DEGREE, LANDINGS , BALCONIES, SHELVES, CHAJJAS, LINTELS, BANDS, PLAIN WINDOW SILLS, STAIRCASES AND SPIRAL STAIR CASES UPTO TO FLOOR FIVE LEVEL EXCLUDING THE COST OF CENTERING, SHUTTING AND REINFORCEMENT WITH 1:2:4 ( 1 CEMENT : 2 COARSE SAND : 4 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE). 10 ReinforcementforR.C.C. workincludingstraightening,cutting, bending, placing in position and binding all complete. Cold twisted bars 11 Takingoutdoors,windowsandclerestorywindowshutters(steelor wood) including stacking within 50 metres lead: Of area 3 sq. metres and below 12 Dismantling roofing including ridges, hips valleys andgutters etc., and stacking the material within 50 metres lead of: Asbestos sheet 13 Finishing walls with water proofing cement paint of required shade : new work(two or more coats applied @3.84kg/10 sqm) 14 PROVIDING AND APPLYING WHITE CEMENT BASED PUTTY OF AVERAGE THICKNESS 1 M.M. OF APPROVED BRAND AND MANUFACTURER OVER THE PLASTERED WALL SURFACE TO PREPARE THE SURFACE EVEN AND SMOOTH COMPLETE. 15 WALL PAINTING WITH ACRYLIC EMULSION PAINT OF APPROVED BRAND 16 Paintingwithsyntheticenamelpaintofapprovedbrandand manufacture to give an even shade :Two or more coats on new work 17 Centeringandshutteringincludingstrutting,proppingetc.and removal of form for : Suspendedfloors,roofs,landings,balconiesand access platform. 18 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked for doors including cost of cutting floors as required embeding in floors and cover plate with brass pivot and single piece M.S. Sheet outer box with slide plate etc With Brass cover plate 19 Demolishingcementconcretemanually/bymechanicalmeans including disposal of material within 50 metres lead as per direction of Engineer - in - charge.1:3:6 or richer mix 20 DemolishingR.C.C.workmanually/bymechanicalmeansincluding stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 21 Carriage of material by mechanical transport including loading, unloading and stacking:Lime, moorum, building rubbish:Lead 1 KM. 22 Providingandfixingonwall faceunplasticised RigidPVCrainwater pipes conforming to IS : 13592 Type A including jointing with seal ring conformingtoIS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. 110 mm diameter 23 Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Shoe (Plain)- 110 mm 24 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 MM 25 Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Bend 87.5°- 75 mm bend 26 PROVIDING AND FIXING BRIGHT FINISHED BRASS 100 MM. MORTICE LATCH AND LOCK WITH 6 LEVERS AND A PAIR OF LEVER HANDLES WITH NECESSARY SCREWS ETC. COMPLETE.(BEST MAKE OF APPROVED QUALITY) 27 REMOVING DRY OR OIL BOUND DISTEMPER BY SCRAPPING, SAND PAPERING AND PREPARING THE SURFACE SMOOTH INCLUDING NECESSARY REPAIRS TO SCRATDHES ETC. COMPLETE. 28 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). 29 PROVIDING AND FIXING 6 MM DIA. G.I. LEVEL ADJUSTING HANGERS (UPTO 1200 MM LENGTH), FIXED TO ROOF SLABS BY MEANS OF CEILING 30 Structural steel work riveted bolted or welded in built up section,trusses and framed work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
26.
Defence #11150449 AOC
Tender For Provision Of Offers Mess Under Ge (N) Udhampur; 2 Construction of block of Offrs Mess complete all as shown on drawings and as specified. 3 Construction of block of Servant Quarter complete all as shown on drawings and as specified. 4 Construction of block of Car Garage (09 Cars) complete all as shown on drawings and as specified. 5 TotalAmount of Sch A Part - II (Internal Water Supply Work) 6 TotalAmount of Sch A Part - III (Internal Electric Supply Work) 7 TotalAmount of Sch A Part - IV (Plumbing Work) 8 TotalAmount of Sch A Part - V(Area Drainage Work) 9 TotalAmount of Sch A Part - VI (Sewage Disposal Work) 10 TotalAmount of Sch A Part -VII (Road, Path, Culvert and Hard Standing Work) 11 TotalAmount of Sch A Part - VIII (External Water Supply Work) 12 TotalAmount of Sch A Part - IX (External Electric Supply Work) 13 TotalAmount of Sch A Part -X (Compound Wall , Fencing and Gate Work) 14 TotalAmount of Sch A Part -XI (Hot Water Supply Work) 15 Sch A Part - XII (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 16 Construction of septic tank for 50 users (Brick construction) complete all as shown on drg No. CEUZ /TD-1585/2021 sheet 1/4 to 4/4 and as specified. 17 Construction of soakage well (Brick construction) 1.8m dia and 3.0m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. 18 Supply, installation and comminssioning of water cooler, fully stainless steel, electric driven single phase having storage capacity 120 litres and nominal cooling capacity of 60 Litres per hour, fitted with hermetically sealed air compressor operating on refrigerant R-134a or 410a, conforming to IS-1391 Part-II) complete all as specified and directed. 19 Supply, installation and comminssioning of refrigerator, double door BEE 5 star rated frost free, digital inverter with hermetically sealed compressor of min capacity 256 litres suitable to use on 230 volt, AC supply complete all as specified and directed. 20 Supply, installation and comminssioning of metal top deep freezer BEE 5 star rated hard top having capacity 320 litres, double door, single phase 240 V, 50Hz, complete all as specified and directed. 21 Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed. 22 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating inverter technology and EER 3.2, single phase, capacity 1.5 TR, complete all as directed. 23 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating inverter technology and EER 3.2, single phase, capacity 2.0 TR, complete all as specified and directed. 24 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed. 25 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. 26 Supply, installation, testing and commissioning of solar hot water heating system (Flat plate collector) based on indirect transfer of heat for 300 liters as per IS-12922 and IS-12978 with electrical backup of 2KW, including angle iron support (60mmx60mmx6mm) with nut, bolts, washers and painting with two coat of synthetic enamel paint over one coat of red oxide primer for mounting of hot water plant and cold storage tank, complete all as specified and as directed.Note:- Cold water storage tank shall be measured and paid separately. 27 Construction of valve pit of size (90x60x60)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 coping with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts in coping including painting of steel surface with two coats of synthetic enamel paint over a coat of redoxide primer as finishes coat including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed. 28 Supply , installation, testing & commissioning of transformer of capacity 100KVA step down outdoor type level - III, copper wounded, 11/0.433KV (at no load) AC 3 phase, vector group Dyn 11, 50HZ on secondary side double wound oil immersed naturally air cooled with external cooling tubes /radiator , delta connected as on primary and star connected with netural brought out on secondary side and having tapping at -2.5% to +7.5% in steps of 2.5% to be changed by external hand operated self position off load tap change switch. Also provision shall be made for locking the taping switch handle in position. The maximum temperature rise shoud not exceed 35 degree centigrade on top of oil when measured on thermometer and 40 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirming to IS 1180-2014 transformerlossess shall be as per latest ammendment No IV as per IS 1180 part - I 2014 and comprising of following accessories complete all as specified and as directed. (Contd.../) 29 a) 03 No porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods nuts.b) 01 No cable end box on LV secondry side consisting of 05 No porcelain bushing (One No neutral earth, One No Neutral and 3 No for phaseconnected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 400 Sqmm cable 3 runs, LT 1100 V grade XLPE insulated heavy duty including gland joint complete. c) Oil conservator with filter type drain valve and oil level guage.d) Dehydrating breather with first filling of dehydrating agent e) Explosive vent.f) THERMOMETER pocket including temperature gaugeg) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strips.(Contd.../) 30 h) OneNo thermometer dail type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge : Max reading painted terminal.i) Rating plate with terminal plate.j) Oil level guage.k) Oil drain filter valve.l) Oil filling hole on top cover with plug.m) Air release valve/plug.n) 4 Nos plain solid cast steel detachable rollers. o) First fill of tranformer oil conforming to relevent ISI and tested upto 60 KV dielectric strength.p) Two No lifting hook at side of transformerNote : Transformer must be as per Energy efficiency Level-3 of IS: 1180:2014 with amendment No. 4. 31 Construction of PCC platform for transformer of size 3m x 3m and 1m high from ground level with brick construction in walls and steps, PCC 1:5:10 type E-2 in foundation, brick workin CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushedstone aggregate). In flooring40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer complete duly surrounded with XPM fencing of length not less than 15 meter and width not less than 10 meter complete with 40mmx5mm angle iron & 12mm dia steel bars, fixed on PCC gate pillers complete including sliding bolt, locking arrangements hinges and all accessories,shown on drawing No CE/TD/1129/96 sheet No. 1/2 & 2/2complete all as specified. 32 Earthing complete with galvanized steel earth plate electrode600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 33 10W decorative inverted tripod type LEDBollard with IP-65 protection, soft 360 degree light distribution body made of die cast aluminium & in triangular shape including 10 W LED with IP 65 ingress protection, 4 KV surge protection, Luminaire should have high efficiency isolated poted driver minimum height of bollard 800mm & with 180mm OEM should have inhouse NABL approved Lab & submit LM-79 report along with NABL certificate, PCC foundation with necessary nuts & bolts complete all as directed by GE. 34 Post top lantern, LED type, 40 watt including40 watt LED AC, outdoor type with decorative post top for 360 degree indirect light IP 66 protection with impact, glare free and better uniformity and corrosion resistant, LED driver shall be constant current type potted driver, luminaire shall have surge protection devices of minimum 10KV inside the driver compartment. Total harmonic distortion shall be <10% with power factor minimum 0.95.The driver shall have an effiviency>85%. It should give consistent performance in the input voltage range of 120V-270V at 50Hz, luminaire shall be embossed or screen printed with manufacturer name/logo, OEM should have in house NABL approved lab and submit LM79 report along with NABL certificate, PCC foundation with necessary nuts and bolts complete with driver and lamp complete all as specified and as directed. 35 Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 36 Sintex box of size 155mmX210mmX92mm, hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cablefor phase and neutral fixed on polewith the help of MS nuts bolts and MS clamps; 2 No of size 40mm X 4mm thick, with one No MCB SP 6 Amp capacity mounted on din rail inside box, including making suitable hole in pole to take out connections to fitting if required at site and provisioning of conector of street light, complete all as specified.Make:- Hensel, Sintex or equivalent make approved by GE. 37 LED street light fitting 70 Watt, 230 V, AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed. 38 Supply, installation, testing and commissioning offactory made outdoor type CPRI approved dust and vermin proof LT panel board front opening (double shutter) with locking arrangement of suitable size made out of 3.15 mm thick CRCA sheet with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring,thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1)of suitable size as per panel board 0.5mtr above ground level grouting and bottom portion of enclosure shall be minimum 30cm above ground level of legs of angle ironand supply & comprising of the following including internal pre-wiring complete:- 39 INCOMING(i) MCCB 4 pole 160 Amp 16 KAKA thermal magnetic adjustable type- 01 No. (Incoming) (ii) Voltmeter 0-500 V with selector switch(Digital type) - 01 set. (iii) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set(iv) Indicator lamp neon/ LED type RBY -01 Set of three.v) Aluminium bus bar capacity 250 Amps for Phase-R-Y-B- N - 4 No.OUTGOING:(i) MCCB 3 pole 125 Amp 16 KA thermal magnetic adjustable type -02 No. (Outgoing)(ii) MCCB 3 pole40 Amp 16 KAKA thermal magnetic adjustable type01 No. (Outgoing)(iii) MCB SPN 32 Amps 10 KA - 01 No (Outgoing)(iv) Time switch 250 V single phase of 20 Amp rating - 01 No(v) Complete wiring of the panel board with FRLSH PVC insulated multistrand copper conductor cables of suitable current carrying capacity end terminated with lugs and bolts, nuts and washers of galvanised iron.Note: The rate quoted should include the cost ofexcavation/PCC work as per manufacturers recommendation. 40 Bracket made out of GI tubing 40mm dia, light grade 1.5mtr long including fixing withMS clamps - 2 No made out of 50mm wide, 5mm thick, flat iron with M.S nuts bolts 75 mm long 12mm dia, - 4 No with flat washer (3mm thick) - 02 No including painting with two coats of aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete, including 1.5sqmm 3.0 core, flexible Copper cable from juction box to connecter of street light fitting complete all as specified and as directed. . 41 Cable route marker with route indication at every 30m length on cast iron disc of 100mm dia and 5mm thick, marked/written for HT cable 11000 VOLTS embosed including indication direction fixed/bolted to 40mm x 40mm x 6mmthick MS angle iron support of 0.50 m long embedded upto 200mmdepth in concrete block of size 200mmx200mmx500mmcasted in PCC 1:3:6 type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surface, complete all as specified and as directed. 42 Road crossingby adopting trenchless tunneling work through specilised pipe jacking method by errecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any kindof soil including hard rock,inserting DWC HDPE casing pipe in any length, and necessary conveyance charges of machinery and other required materials in co-ordination with the concered authorites all as specified and as directed. Note: Quoted rate is deemed to be inclusive of all necessary tools/plant/machinery and obtaining necessary permissions to carryout the work. 43 Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc; metal flush boxes suitable modules as directed with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLSHunsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- 44 One light/fan/bellpoint controlled by one switch 45 One 3/5 pin socket outlet, 5 Amp on independent board 46 One socket outlet 3 Pin, 5 Amps, on the same board 47 One two way point controlled by one 2 way switch 48 One light point controlled by 2 way switches, 49 Point wiring for power point control by one switch with 2.5 Sqmm nominal area PVC insulated single core multi standard copper conductor FRLSH insulated and undheathed heavy duty cable in colour code including earth wire with cable of size 2.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed in PVC conduit of not less than 20mm dia and 1.5mm wall thickness (ISI marked) terminated into annealed steel terminal boxes including modular frame and cover plate for fixing of switches, sockets etc; complete all as specified and as directed. 50 Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia, medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly, complete all as specified and as directed.Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 51 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmmas earth continuity conductorconnected to commen earth dolly complete all as specified and directed.Note: - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 52 Sub main wiring with four run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including two run ofsingle core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed.Note: - Four run of 6 sqmm single core copper conductor cable and two run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 53 Sheet metal, VTPN distribution board (DB) fitted with DPX3, 160 MCCB, 04 way, (DPX3 -160 +12), complete with metal door, 415 volts rating and IP 56 protection the DB shall be fixed flush to wall and including all internal connection, necessary reducer lugs all as directed by Engr-in-Charge. 54 MCB, Single pole, 240 volt, 40 Amp, 10KA rating,C curve, complete with connection testing and commissioning, complete all specified and directed. 55 Deduction to be made from BOQfor Sch A Part -XIII (Schedule of credit) during AOC.Note: Tenderers shall not quote for this schedule.
Contract Date: May 23, 2026 Contract Value : 4.61 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Jammu And Kashmir View Result →
27.
Defence #11149786 AOC
Tender For Provision Of Deficient Smqs At Najafgarh Under Ge Af Tughlakabad - SCH A PART XI (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule A Part-II. 11 INTERNAL WATER SUPPLY 12 Supply and fixing Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia fixing in pipe with 1.25 meter long flexible tube and ABS wall hook including making connection and fixed to 15mm bore completeall as specified and directed. 13 Supply and fixingangle valve of cast coper alloy chromium plated fancy type screwed down high pressure with crutchor butterfly handle screwed both ends for iron pipe or for unions and fixed 15 mm bore (concealed) complete all as specified and directed. 14 Supply and fixing 15mm dia Two Way Bib taps, fancy type,,cast copper alloy chromium plated with crutch or butterfly handle, screwed down for CPVC pipe or for brass ferrule and fixed complete all as specified and as directed. 15 Supply and fixingBrass CP Mixer for mixing hot & cold water screwed down for 15 mm dia CPVC Pipe and fixed all as specified and as directed. 16 INTERNAL ELECTRIFICATION 17 Supply and fixing LED Lamp 9 watt 220 volts AC of suitable size complete all as specified and as directed. 18 Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 19 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 20 Supply and Fixing LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.complete all as specified and as directed. 21 Supply and fixingLED Building Securitylight fitting 25 watt complete all as specified and directed by Engr -in- charge. 22 Supply and fixingGI light gradepipe 1.5m long bend to 45 degree andof diameter 25 mm suitable to building security light power cord pipediameter with necessary clamps of for fixing building security light all as specified and directed including making hole to wall if necessary (For Bldg Security Light) complete all as specified and as directed. 23 Supply and fixing MCCB 63 Amps 4P 25 KA 415 Volt Make Indoasian Cat No 830020 includingMCCB Enclosure for 63 Amp MCCB Make Indoasian Cat No 811985 fixed on wooden board of appropriate size for mounting of enclosure complete all as specified and as directed.NOTE:-Rate inclusive of Fixing of cable including lugging complete (For06 Qtrs) 24 Supply and Fixing ceiling fan 230V, 50 Hz AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed. 25 Supply and Fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm (for Toilets) complete all as specified and as directed. 26 Supply and Fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m (for Kitchen) complete all as specified and as directed. 27 Supply and Fixing electric water heater, storage type steel body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate, NRV, connection piece etc. complete all as specified and as directed. 28 Supply and fixing Smart RF/CellularSingle Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 315 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Radio Frequency communication facilitywith self healing mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry including Polycarbonate Meter Box of minimum suitable size for 1 Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per prevalent IS . Including Taking down of existing meter and deposit to MES store yard for safe custody all as specified and as directed (For06 Qtrs)Note:- Contractor has to ensure integration and maintainance of the above 06 nos of meters withthe existing Advance Metering infrastructure (AMI) of smart meters of different makeswithout any additional infrastructure and cost implication. 29 EXTERNAL WATER SUPPLY 30 Material and Labour for valve chamber of internal size 750x750x750 mm comprising of 50 mm thick PCC 1:5:10 type E2 foundation, 200 mm thick brick wall in CM 1:6 ,15 mm thick plastring in CM 1:4 internally and externally up to 50 mm below GL, 100 mm thick PCC 1:3:6 type B1 as in coping, 3 mm thick MS sheet cover with suitable hinges and locking arrangements, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed. 31 EXTERNAL ELECTRIC SUPPLY 32 Supply and fixing of LED security/street light fitting 1x70 W LED 5700K energy saving and environmental friendly long life versatile pressure die cast aluminium hosing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LEDs as light source and electronic driver suitable for pole dia 40mm including 45mm dia light grade tube bracket, bent to shape, 1.8 mtr lenght with two Nos clamp of size 50mmx6mm with nuts,bolts,washers etc. including connection with 1.5 sqmm two single core PVC insulated and PVC sheathed cable stranded copper conductor upto ceiling rose and fixing on walls/pole complete all as specified and as directed. 33 Supply and fixingof LT Panel board outdoor type, double door, fabricated made of MS/CRCA sheet 3.15 mmm thick with MS angle frame of size 50x50x6 mm with locking arrangements cubical type feeder pillar box with 04 Nos legs including necessary PCC work with suitable size of PCC 1:3:6 including necessary insulators and 04 Nos of copper bus bar of size 30 mm x 5 mm capacity of 600 Amp with Air circuit breaker, provision of inlet and outlet cable glands and earth connection lead etc complete and connection of all incoming and outgoing cable using aluminium terminal sockets/lugs duly crimpled and necessary two coats of paint with approved make and colour and grade of first quality synthetic enamel paint over a coat of red oxide primer including necessary preparation of surfaces and the panel should be dust and vermin proof factory fabricated , CPRI approved totally enclosed free standing /wall mounting type suitable for 415 vots, 50 HZ 3 phase 4 wire system complete in all respect and confirming to latest relevant of ISI specifications including necessary connections, inter connections with copper conductor cable of required size including MS angle frame of size 50x50x6 mm structure at bottom and with including the following accessories.:- 34 INCOMING :- (i) MCCB,AC 415 Volts, adjustible thermal release, 4 pole current rating 63 Amps, breaking capacity 16 KA (ICS=ICU=ICW for 1 Sec) with fixed type overload protection,short circuit protection = 01 No.(ii) 4 strip copper bus bar of size 30 x 5 mm with specific colour (R,Y,B) insulation = 01 set(iii) Metering panel comprising,voltmeter and ammeter, digital type with selector switches CTs, control fused and indicating lamps. OUTGOING : (i) MCCB,AC 415 Volts, adjustible thermal release, 3 pole current rating 32 Amps, breaking capacity 16 KA (ICS=ICU=ICW for 1 Sec) with fixed type overload protection,short circuit protection = 02 Nos for (01 No Building & 01 No. spare) (ii)MCB SPN 32 amp 215 volts C curve (for street light) = 01 No.(iii) Digital Voltmeter 0-500 volts - 01 No.(iv) Digital Ammeter 04-400 Amps - 01 No. (v) Indicator lamps Red, Yellow & Blue.(vi) Complete wiring of Panel Board.(vii) CT ratio 400/5 Amps 35 Supply and fixing SMC junction box, pole mounted, 100% weather proof, fire retardant , complete with side hinged door of size 250x200x105 mm , made out of engineering plastic including 3 phase 4 wire aluminium bus bar of capacity 60 amp of required size complete with bus bar insulator fibre/ porcelain and one no single pole MCB SPN 6 Amp . B Curve and box fixed on pole with clamps made out from MS flat iron of size 25x5 mm with nute and bolts complete all as specified and as directed. 36 Material and Labour for sub main wiring with 2 run of 1.5 sqmm multistand copper conductor , PVC insulated, 1100 volts grade in and including PVC condut with 1.5 sqmm PVC insulated multistrand copper earth continuity conductor including lugs of suitable size from light fitting connector to looping box on pole complete all as specifed and directed. 37 AREA DRAINAGE 38 Material and labour for pre-cast perforated RCC drain cover with frame ( rectangular or square) the area of each cover should not be more than 0.5 square meter and thickness of 60 mm each with holes, manufactured with M-30 grade of concrete by vibro compacting process using accurately designed moulds and suitably reinforced to enable the covers to take load as specified i.e M-20 MT for heavy duty (When tested as per IS -12592) complete all as specified and as directed. 39 SEWAGE DISPOSAL 40 Supply, laying in trenches and jointing of 200 mm dia bore double wall corrugated polyethelene (HDPE) pipe of stiffness class designation SN8 including all necessary jointing material and fittings such as couplers, connectors,bends, elbows ,Tees and end caps etc complete all as specified and as directed
Contract Date: May 22, 2026 Contract Value : 1.91 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
28.
Public Administrative Department #11142241 AOC
Construction And Carry Out Ancillary Works For Urban Ayushman Health Temples (Uhwc) In Porta Cabins At 14 Places In The Jurisdiction Of Thane Municipal Corporation.-1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. :Means Bd.A.1 Page No.259 2 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means 3 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. 4 Transportation of excavated material including loading and unloading etc. complete. (c) lead up to 5 km) 5 Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. 6 Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. 7 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 8 Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) 9 Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer incharge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. 14 Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 15 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. 16 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. cover of 75 Kilogram with lid and frame fixed in cement concrete.. Spec. No. 17 Providing and laying in trenches 25 mm dai. UPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 18 Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying) 19 Providing and making ISI Mark ferrule connection of 25mm dia.to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. 20 Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters 21 Supplying, erecting, testing and commissioning of minimum three and above star rated centrifugal water pump (monoblock),230 V,single phase,50 Hz,AC.supply of 0.375kw/0.5 HP with discharge 36/9 lpm for head of 6/21 m & 25 mm suction /25 mm delivery pipe on provided CC foundation as per specification no.WP.CGP. 22 Supplying, installing and testing earthing with copper earth plate 30 x 30 x 0.315 cm complete with all accessories of copper materials and recording the results as per specification no.Ea-EP Supplying, & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 Kg.capacity cartridge type conform to IS 2878/15683 complete erected with necessary clamp made from 50 x 6 mm M.S. flat with nut & bolts rounded in wall complete. Supplying, & erecting Hand dryer machine having speed jet of warm air with low noise blower to quick dry wet hands,power 1800 W,voltage 230V,50 Hz.Automatic cut off after 5-10 second. Providing,Supplying and fixing electrical meter with all necessary accessories,required cable for connection from main supply including required permission from MSEDCL,TORRENT and Local authorities.(The contractor shall submit the original receipts of payments made to MSEDCL, Torrent Power co.The payments will be made as per the actual expenses made by contractor for each permission and purchasing of electric meter.) Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Supplying and laying (including excavation) 50 mm outside dia double wall corrugated pipe (DWC) of HDPE for enclosing cable below ground/road surface to required depth completed Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Providing, Supplying and installation of Porta Cabin Fabricated at Factory Scope of work per cabin shall includes as follows 1. Specification mentioned as below 2. Internal and external arrangement of cabin as per drawings as attached 3. Works of Plumbing, sanitary, electrification, CCTV 4. Furniture as below a. Executive Chairs (as per sr.no.3) - 3 nos, b. Visitor chair (as per sr.no.4) - 6 no c. Two seater chair (as per sr.no.5) – 2 Nos d. Three seater chair (as per sr.no.6) – 5 Nos e. Patient Examination Couch/Table (as per sr.no.8) – 2 Nos f. Storage Cabinet (as per sr.no.9) – 1 Nos g. Table (as per sr.no.10) – 4 Nos h. Table (as per sr.no.11) – 1 Nos i. Medical Store Racks in pharmacy room (as per sr.no.12) – as per drawing j. Trash Bin (as per sr.no.13) – 6 Nos k. Seating tools (as per sr.no.7) – 6 Nos Detailed Description and Specification: Unit Size – L x B x Ht = 30 ft x 20 ft x 9 ft (Clear internal Height) Cabin should be structurally stable and suitable to meet severity of climatic conditions. Sustainable in wind condition of 55m/s- in Seismic zone IV and ambient temperature range (-) 40 degree C to (+) 50 degree C. Bottom Frame 80 x 40 x 2mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener Bottom 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Top Frame 80 x 40 x 2 mm GI Rectangular Hollow Pipe (Apollo Make) Stiffener (Top Frame) 50 x 50 x 2mm GI Rectangular Hollow Pipe (Apollo Make) for Shorter Span and 80 x 40 x 2mm for longer Span making the grid of 2ft x 2ft. Please note Base frame shall be quoted with special type of anticorrosive paint to avoid rusting and for better life (i.e. Black Coal Tar Epoxy Paint) Paneling Outside Outside Wall of the cabin shall be made from 16 guage GI sheet with solid color of approved shade, fitted on inside GI pipe framing making the grid of 2ft x 2ft. Paneling Inside Inside wall of the cabin shall be made from 3 MM Thk ACP sheet with aluminum foil thickness of 0.25 mm with solid color of approved shade fitted on inside Gl pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Wall Panels shall be completely insulated with Glass wool of 48 kg/m3 Density and slab thickness 50mm. Corners Pole 72 x 72 x 3.2mm GI Rectangular Hollow Pipe (Apollo Make) with black coal tar epoxy coating Plumbing Arrangement UPVC concealed internal plumbing system shall be provided with all necessary inlet and outlet points as per the Drawing. External water connection shall be Provided by TMC. Drinking Arrangement Providing and Fixing branded water purifier of make like Aquaguard, Kent, LG or equivalent with all necessary connections, fittings accessories with storage arrangement etc. complete Sanitary Fittings All plumbing and sanitary fittings such as Ceramic Western Commode with seat cover, Ceramic Indian Commode, Ceramic urinal with push pillar cock, Ceramic Wash Basin, Wash basin Push Pillar Cock shall be of brand like Kajaria, Hindware, Paryware or equivalent. All western Toilets must be equipped with jet Spray, 2 in 1 Taps and Flush Tank. Accessories for PWD persons shall be provided in all toilets. (Excluding External Sewerage Connection). Roof Outside Roof Slope 1:2 one way 126 Roof shall be made from 1.2 mm 120 GSM GI sheets of Jindal make, which shall be fully welded and sloped to avoid leakage. All the roof joints shall be covered with 75mm Butyl Vinyl Tape. Roof shall be covered with Heat Resistant paint to maintain low temperature inside the cabin. Roof Gutter Specially designed gutter section shall be provided to drain water at the single side of the cabin. This shall be made from 1.2 mm 120 GSM GI sheet Jindal make including fitting arrangement. False Ceiling False Ceiling shall be made from 3 mm Thk ACP sheet with Aluminium foil thickness of 0.25 mm with solid colour of approved shade fitted on inside GI pipe framing making the grid of 2ft x 2ft. All the ACP joints shall be filled with Black silicon. Flooring Flooring shall be made from 18 mm High Strength Bison board/ Cement fibre sheet, which is covered with 2 mm PVC vinyl flooring for cabin. For toilet Cement sheet shall be covered by 10 mm thick 1 X 2 ceramic tiles which shall be fixed by using tile adhesive and cement mixture of at least 50mm Thk. Doors & Door frame Main Door Flush door 32 mm thick waterproof material with 4mm Glass as per approved design and drawing and door frame shall be made from aluminium Section. Locking arrangement along with D Handles in SS 304, door closer, door stopper etc. Door Size: 5’x 6’ Internal doors shall be sliding doors/ flush door of size as per drawing and as per the specifications decided by engineer-in charge Toilet Door and door frame shall be made from aluminium frame with 4mm Glass and ACP including locking arrangement, Handles in SS 304, Door Size: 2’-6’’ x6’ Windows Powder coated aluminium Two Track sliding windows with 4 mm tinted Glass. Size of windows as per drawings. M.S. Grill of weight @ 20 kg per sqm shall be provided to all windows/louvered window from outside. Curtains of good quality and curtain rod/track with fixtures shall be provided from inside of windows. Insulation False Ceiling and Wall Panels shall be completely insulated with Glass wool of 48 31 Providing, Supplying and installation of Porta Cabin Fabricated at Site Scope of work per cabin shall includes as follows 32 Providing, laying and fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per IS ..1237 - 1980 having compressive strength more than 500 Kilogram/sq.cm reaffirmed in 2006 ,having wert transvrse strenghth of 3.5 / mm 2, water absorption less than 10 % abrasion / wear resistance less than 2 mm, skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300 in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring. 33 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 34 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 35 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 36 Testing :- Compressive test of C.C.Cube 37 Provide and supplying Executive Chairs A generously cushioned, molded PU seat combined with breathable mesh fabric, Crafted from strong and durable Polyamide (Nylon) featuring a reinforced mesh back, chair equipped with BIFMA Certified Class-4 Hydraulic Gas Spring and BIFMA Certified 60mm Wheel Castors. Chair having 3 years warranty (Executive chairs) / or equivalent / as Directed by Engineer Incharge. Key Features Colour : GREY / Black Material : Metal Dimensions : 64D x 61W x 119H Centimeters Size : Standard Back Style : Mesh Back Special Feature : Adjustable Lumbar, Adjustable Height, Adjustable Arm Rest, Adjustable Head Support Seat Material Type : Breathable Microfiber Cloth Covered in PU Foam 38 Providing and supplying visitor chair having size Depth- 62cm, width-55cm, height- 80cm & seat height 45 cm. (+/- 2cm ), having seat & back, shall be made up of 1.2 cm hot pressed plywood, approved tapestry upto Rs.300/m and mould polyurethane foam with P.V.C. lipping all around etc. complete. The chair shall be provided with two one piece armrest made of polypropylene. The chair shall be supported by cantilever type powder coated tubular frame dia 2.54cm x 14 B G M.S.E.R.W. tube. All aluminium steel component shall have Epoxy Polyster Powder Coated. The chair shall be Ergonimc Dry film thickness shall be more than 45 Micron. And as directed by Architect in charge. The over all appearance of the product shall be as per photograph. All metal work shall be Epoxy Polyster Powder Coated and as directed by Architect in 39 Public Seating Chair. - 2 Seater Providing and Fixing 2 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish with 1 year warranty etc complete as directed by engineer in charge.. 40 Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 41 Seating tool for Lab and Class-IV Providing and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. 42 Providing and supplying examination couch. This examination couch features an adjustable backrest that can be easily operated using a gas spring system. The twosection foam-padded top provides added comfort for patients during examinations. It is equipped with three drawers and three cabinets, offering ample storage space for medical equipment and supplies, keeping everything organized and easily accessible. A tray for the B.P. apparatus is conveniently placed near the headrest, ensuring easy access for medical professionals. The couch is finished with pre-treated epoxy powder coating, making it durable and easy to clean, while also ensuring resistance to corrosion Designed with a carrying capacity of 150-180 kg. etc complete. as directed by engineer in charge. Key Features Adjustable Backrest: The backrest is adjustable using a gas spring system, providing flexibility for various examination positions. Foam Padded, Upholstered Top: Offers comfort and support during patient examinations. Ample Storage: Equipped with three drawers and three cabinets to store medical supplies and equipment. BP Tray: A tray near the headrest for easy access to BP apparatus. 43 Providing, supplying and installing the cabinet, dimensions of 1200mm (W) x 1660mm (H) x 450mm (D) and is constructed from prime quality 0.8mm thick CRCA steel for the body panels and shelves. The shelves are adjustable in height and have a uniformly distributed load capacity of 50kg per shelf. The vertical sides feature continuous slots for mounting shelves at variable heights. The entire carcass is finished with a 50 ±10 microns epoxy polyester powder coating. The facia of the cabinet consists of metal shutters with metal borders, incorporating toughened glass panels. The handles are Dshaped in an aesthetically pleasing design with a stainless steel (SS) finish. The locking mechanism uses a metal cam lock for security. Additionally, the cabinet is equipped with adjustable levelers featuring plastic bases, allowing height adjustments of up to 15mm.This furniture is built according to the specifications and samples approved by the client. It meets the required certifications including ISO 9001:2015, ISO 14001:2015, ISO 45001:2018, BIS standards, and is a BIFMA Gold certified member. The product comes with a 5-year warranty. Installation and other details are as directed by the engineer in charge. 44 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1060mm x D600mm x H750 mm -1 No W900mm x D300mm x H750 mm – 1 No W600mm x D450mm x H750 mm – 2 No As Directed by Engineer Incharge 45 Providing & Fixing of HNI Make table of Size. The Worktop shall be made of 25mm Prelam particle Board of Grade II , Type-II as per IS:12823 and backing laminate of 0.6mm All the exposed edges are finished with 2mm thick PVC lipping machine pressed. Legs are made of powdered coated steel 50mmx 50mm Section. Cross Member are in CRCA steel and the Beam is made of MS of 1.5mm thickness in powder coated finish of 50 microns thickness. The above furniture should be as per specification with 3 years warranty etc. sample approved by client. TABLE SIZE :- W1200xD700xH740mm As Directed by Engineer Incharge 46 Providing and supplying adjustable MS storage rack having size 1200 mm to 1800mm x 300 mm x 1600 mm including all transportation upto site etc complete as directed by engineer in charge. Key features 1. Material  Frame : Mild steel (MS) powder coated  Shelves: Cold-rolled steel (CRCA) or galvanized  iron (GI) 2. Angle Specifications  Size 40 x 40 x 2.50 mm  Length : Standard lengths of 6 feet, 8 feet, or 10 47 Providing and supplying trash bins with a maximum height of 450mm 35 - 40 liter, made of high-quality molded plastic for durability and ease of maintenance. The bins shall be equipped with a functional lid mechanism and shall be provided as per the approved selection and design. The work shall be carried out as directed by the Engineer-In-Charge etc complete . 48 Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. 49 Providing and Laying M60 grade cement concrete of approved mix design with avg. Flextural strength of 4.4 MPa in 3 days from R.M.C. plant incld. use of micro silica/alcofine, approved make super plastiser and retarder, fibriliated 100 % virgin polypropylene fibres, fly ash and transported by transit mixer and placing at work site. Compacting, finishing, initial curing by approved curing compound/contractors water and tarring the sides of slab with hot bitumen as specified and as directed (w/c ratio 0.28 max.). (vatta for curing will be paid separately) for Ultra thin White Topping (UTWT) pavement. etc completed. Providing second class Burnt Brick masonry with conventional/I.S .type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mild steel plated, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two. coats of oil painting approved quality and shade etc. complete. Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meter made out of 4 mm aluminum sheet bonded with white retro reflective sheeting of Class C ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity microprismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorized distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier. Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminum-Zinc alloy (55% aluminum 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) Providing Excavator (JCB JS 80 or equivalent) of 0.9 Cum etc complete Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec. One Number: As directed by Engineer- in-charge. Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete. Providing and laying Cast in situ/Ready Mix cement concrete M-15 trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Providing tuck pointing with cement mortar 1:3 for stone/Brick masonry including scaffolding and curing etc. complete. Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts etc. Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259 Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. Transportation of excavated material including loading and unloading etc. complete. ( (c) lead up to 5 km) Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Providing soling using 80 mm size trap metal in 15 cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer in charge. Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineerin- charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete. Providing and fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use).Spec. No As director by engineer in charge. Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.Spec. No As director by engineer incharge. Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Painting letters upto 20 centimetre height including cost of brushes, coir brushes dusting, cleaning etcetera complete. Spec. No. As Directed By Engineer In Charge. Only For Road Side Furniture. Spec .No. MORTH 801 Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573. etc
Contract Date: May 21, 2026 Contract Value : 4.09 Crore
Local Bodies No of Bidders 2
Maharashtra View Result →
29.
Defence #11117617 AOC
Tender For Provision Of Training Shed And Pt Shed At Varanasi; Design, fabrication, supply and erecting, Pre-engineered building steel structure/LGSF made from 345 Mpa high strength Hot rolled paletes and factory produced zincalume cold rolled light gauge steel zincalume frame (1 mm BMT)for provision oftraining and PT Sheds of size 72 metre x 18 metre x7.95 metre height from FFL to bottom of truss using 0.45 mm base metal thickness, pre-painted 0.50 mm corrugated galvalume aluminium zinc coating (AZ-150 GSM) aluminium zinc alloy coated colour having tensile strength of 550Mpa as in roofingfixed with self tapping screws including S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.60 mm thick (AZ not less than 150) of colour having tensile strength of 550Mpa as in ridge/valley gutter roof covering/cladding to wall fixed with self tapping screws, (factory made valley gutter, shape and size directed by Engineer-in Charge including supply of bolts, gutter bolts, screws, washer, pipe nails distance pieces, plug, holder bats for pipe and all jointing materials, down take pipe, downspout pipe and metal clamp of appropriate size and shape and LGSF structure with brick work in CM 1:4 onas per mentioned in architectural drawing all as specified with following design parameters all as specified and vetted design and drawing by any IIT/NIT and approved by Chief Engineer Lucknow Zone with permanent specification complete all as specified and as shown on drawing:-(i) Frame type Pre-Engineered Building (ii) Size of training and PT shed as perarchitectural drawing (iii) LGSF structure with 1 mm to 2.5 mm thick(iv) Anti-corrosion treatment and painting as per IS -1477 Part 1 & 2 .(v) PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate including form work in base of footing.(vi)RCC work M-30 in footing, plinth beam & Stair case/steps as per approved mix design and as per IS:9103(vii)All necessary civil works for setting for super structure layout, excavation, back filling, removal of surplus soil, RCC foundation/footing, plinth beam, RCC sitting step with granite finish including bull nosing finish & Stainless steel railing complete.Note : (i) Design parameters of PEB structure is attached as appendix ‘A’ (ii) Following items mentioned under srl no 1.01 to1.13 here-in after shall also be included in lump sum rate quoted against Srl item No 1 of BOQ. 2 Site clearance/site developments 3 Anti termite treatment 4 All primary structural components should be confirmed to IS: 2062 E-350 BR, Having a minimum tensile strength of 490 MPs and pass physical & Chemical tests stipulates therein 5 Purlins and side girt membersshall be made from cold Formed Sections, Confirming to IS : 811, having a minimum tensile strength of 345 MPs. The sheets used for cold forming sections shall confirm to IS : 1079, 2009 quality HR3 6 Permanently colour coated high tensile steel sheet havingminimum base metal thickness of 0.45mm (i.e excluding Aluminium -Zinc/galvanizing & colour coating thickness) & minimum Yield strength of 550 Mpa, coated with 55% Al-Zn alloy @ 150 g/Sqm as per ASTM A792M; Color coated with total minimum thickness of 40 microns (nominal) comprising of Silicon, Modified polyester (SMP with silicon content of 30% minimum) paint or super Polyester paint of minimum 20 microns (nominal) Dry Film Thickness (DFT) on exposed side over 5 microns (nominal) primer coat and 10 microns (nominal) approved colour Epoxy paint on other side over 5 microns (nominal) primer coat as per ASTM A755M 7 Kota stone flooring shall be 18 to 20 mm thick machine cut and polished at site after fixing (Mirror polish/granite polish). Size of Kota stone slabs used in floors shall be not less than 500 mm x 500mm.Kota stone slab shall be laid over 20mm thick screed in CM (1:6) over 100 mm thick PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate over rammed earth. Jointing shall be with grey cement mixed with pigment to match the shade of Kota stone slab. The floor shallachieve mirror finish surface. 8 75 mm thick PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as inplinth protection & Saucer drain. Plinth protection surface finishedeven and smooth without using extra cement of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) 9 Stainless steelrailingwith SS hand rail pipes grade 304 as perarchitectural drawing shall be provided. 10 10 to12 mm thick ready mix plaster on internal surface and external surface of wall. 11 Preparation of newly plaster surface of wall and applying two coats of synthetic enamel paint over a coat of primer on internal and external surface of wall. 12 Ramp provided same as per flooring specification 13 PAINTING SCHEME FOR STRUCTURAL STEEL WORK:(a) Soap paint :- One coat of inorganic zinc silicate primer-75 microns(b) Soap paint :- One coat of polyurethane paint -30 microns(c) Site paint :- One coat of polyurethane paint- 30 microns (after erection & fixing work) 14 Applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer on other than structural steel surface 15 Design, fabrication, supply and erecting, Pre-engineered building steel structure/LGSF made from 345 Mpa high strength Hot rolled paletes and factory produced zincalume cold rolled light gauge steel zincalume frame (1 mm BMT)for provision oftraining and PT Sheds of size 36 metre x 12 metre x 7.95 metre heightfrom FFL to bottom of trussusing 0.45 mm base metal thickness, pre-painted 0.50 mm corrugated galvalume aluminium zinc coating (AZ-150 GSM) aluminium zinc alloy coated colour having tensile strength of 550Mpa as in roofingfixed with self tapping screws including S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.60 mm thick (AZ not less than 150) of colour having tensile strength of 550Mpa as in ridge/valley gutter roof covering/cladding to wall fixed with self tapping screws, (factory made valley gutter, shape and size directed by Engineer-in Charge including supply of bolts, gutter bolts, screws, washer, pipe nails distance pieces, plug, holder bats for pipe and all jointing materials, down take pipe, downspout pipe and metal clamp of appropriate size and shape and LGSF structure with brick work in CM 1:4 onas per mentioned in architectural drawing all as specified with following design parameters all as specified and vetted design and drawing by any IIT/NIT and approved by Chief Engineer Lucknow Zone with permanent specification complete all as specified and as shown on drawing:-(i) Frame type Pre-Engineered Building (ii) Size of training and PT shed as perarchitectural drawing (iii) LGSF structure with 1 mm to 2.5 mm thick(iv) Anti-corrosion treatment and painting as per IS -1477 Part 1 & 2 .(v) PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate including form work in base of footing.(vi)RCC work M-30 in footing, plinth beam & Stair case/steps as per approved mix design and as per IS:9103(vii)All necessary civil works for setting for super structure layout, excavation, back filling, removal of surplus soil, RCC foundation/footing, plinth beam, RCC sitting step with granite finish including bull nosing finish & Stainless steel railing complete.Note : (i) Design parameters of PEB structure is attached as appendix ‘A’ (ii) Following items mentioned under srl no 2.01 to2.13 here-in after shall also be included in lump sum rate quoted against Srl item No 2 of BOQ. 16 Site clearance/site developments 17 Anti termite treatment 18 All primary structural components should be confirmed to IS: 2062 E-350 BR, Having a minimum tensile strength of 490 MPs and pass physical & Chemical tests stipulates therein 19 Purlins and side girt membersshall be made from cold Formed Sections, Confirming to IS : 811, having a minimum tensile strength of 345 MPs. The sheets used for cold forming sections shall confirm to IS : 1079, 2009 quality HR3 20 Permanently colour coated high tensile steel sheet havingminimum base metal thickness of 0.45mm (i.e excluding Aluminium -Zinc/galvanizing & colour coating thickness) & minimum Yield strength of 550 Mpa, coated with 55% Al-Zn alloy @ 150 g/Sqm as per ASTM A792M; Color coated with total minimum thickness of 40 microns (nominal) comprising of Silicon, Modified polyester (SMP with silicon content of 30% minimum) paint or super Polyester paint of minimum 20 microns (nominal) Dry Film Thickness (DFT) on exposed side over 5 microns (nominal) primer coat and 10 microns (nominal) approved colour Epoxy paint on other side over 5 microns (nominal) primer coat as per ASTM A755M 21 Kota stone flooring shall be 18 to 20 mm thick machine cut and polished at site after fixing (Mirror polish/granite polish). Size of Kota stone slabs used in floors shall be not less than 500 mm x 500mm.Kota stone slab shall be laid over 20mm thick screed in CM (1:6) over 100 mm thick PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate over rammed earth. Jointing shall be with grey cement mixed with pigment to match the shade of Kota stone slab. The floor shallachieve mirror finish surface. 22 75 mm thick PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as inplinth protection & Saucer drain. Plinth protection surface finishedeven and smooth without using extra cement of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3) 23 Stainless steelrailingwith SS hand rail pipes grade 304 as perarchitectural drawing shall be provided. 24 10 to12 mm thick ready mix plaster on internal surface and external surface of wall. 25 Preparation of newly plaster surface of wall and applying two coats of synthetic enamel paint over a coat of primer on internal and external surface of wall. 26 Ramp provided same as per flooring specification 27 PAINTING SCHEME FOR STRUCTURAL STEEL WORK:(a) Soap paint :- One coat of inorganic zinc silicate primer-75 microns(b) Soap paint :- One coat of polyurethane paint -30 microns(c) Site paint :- One coat of polyurethane paint- 30 microns (after erection & fixing work) 28 Applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer on other than structural steel surface 29 INTERNAL ELECTRIFICATIONM&L for point wiring completeforOne light/Fan/Exhaust Fan/Bell point/ Bldg Security Light / Industrial wall mounting fancontrolled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 Sqmm(nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 25 mm dia non metalic PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof / floor slab and ceiling, pressed GI concealed terminal modular boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of required colour complete, including suitable cover plate of any module including 1.5 Sqmm PVC, FRLSH cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :-(i) In case of roof/ceiling, heavy duty PVC pipe not less than 25 mm dia shall be used without any extra cost.(ii) Height of socket should be 1.2m above from FFL(iii) Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost. 30 M&L for Point wiring completeforone 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLSH CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 25 mm dia non metalic PVC conduit medium grade concealed in wall / roof / floor slab and ceiling, pressed GI concealed terminal modular boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :-(i)In case of roof/ceiling, heavy duty PVC pipe not less than 25 mm dia shall be used without any extra cost.(ii) Height of socket should be 1.2m above from FFL 31 M&L forPoint wiring completefor power point controlled by oneswitch with PVC insualted and unsheathed FRLSH cable 2.5 Sqmm(nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 25 mm dia non metalic PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 25 mm in roof /wall/ floor slab and ceiling, suitable for modular switch with modular metal flush box with inner and outer cover plate & frame etc of requied colour complete, including 2.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed.Note :- In case of roof/ceiling, heavy duty PVC pipe not less than 25 mm dia shall be used without any extra cost.One circuit controlled by max one points only. 32 S&F Switch piano, flush type 5 Amps single pole, one way complete all as specified and directed. 33 S&F Socket outlet, flush type 2 in 1, 5 pin, 6 Amps, multi-purpose complete all as speci-fied and directed. 34 S&F Switch piano, flush type single pole, one way 16 Amps complete all as specified and directed. 35 S&F Socket outlet, flush type 2 in 1, 5 pin, 5 and 16 Amps, multipurpose complete all as specified and directed. 36 S&F ceiling rose two to three terminal, complete all as specified and directed. 37 S&F BLDC type air circular wall mounting fan 750mm Sweep, single phase 230 V AC, 1440 RPM, air delivery CMM, power consumption 250 watt, with string, 3 speed choice colour mate, 5 star rating & ISI marked alongwith complete accessories and connecting up the fan to ceiling rose incl PVC insulated 3 core 23/0.0076 copper cable & suitable size of flexible cord with plug top from ceiling rose to wall mounted fan arrangement on pillar / wall is deemed under quoted item rate, complete all as specified and directed 38 S & FLED wide beam optics High Bay Light 100 Wdaylight 150 lum/Wwith PDC housingsuitable for ceiling (surface/suspended) rated aluminium housing indoor type with all fixing arrangement, complete all as specified and directed. 39 S&F LED Building security light fitting 35 Watt with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (35W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers, complete all as specified and directed. 40 S & F MCB DB vertical type 4-way VTPN sheet metal enclosures 415 V with 200 Amp fully insulatedstandard copper Bushbar for each phase & sourrounded with neutral Bars & two common neutral bar, two earth bar incl cable ties fo cable management suitable for housing MCCB/TPN 415 V as incommer IP-54 protection with metal doors all enclosed on standard steel sheet flush mounted type double door factory fabricated complete without MCB & MCCB but with enclosure blank plate, complete all as specified and directed. 41 Supply and fixing MCB DB single pole pole with neutral sheet metal enclosure double door type, 240 volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standardsteel sheet flush mounting type factory fabricated powder coated complete without MCB and with enclosure blank plates for unused way suitable for 12- way ISI marked, complete all as specified and directed. 42 Supply and fixing MCB DB single pole pole with neutral sheet metal enclosure double door type, 240 volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standardsteel sheet flush mounting type factory fabricated powder coated complete withoutMCB and with enclosure blank plates for unused way suitable for 8- way ISI marked, complete all as specified and directed. 43 S&F MCB SPN 32 Amps B series, 10 KA-240 Volts, AC ISI marked, complete all as specified and directed. 44 S&F MCB single pole 6 to 32 Amp rating C Series,10 KA240 Volts, AC50 Hz , ISI marked, complete all as specified and directed. 45 S&F MCCB 415 Volts AC, with 100 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCBand with enclosure blank plates for unused way suitable for 4 way, complete all as specified and directed. 46 M&L for submain wiring with two single core 4 sqmm copper conductor FRLSH, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 25 mm dia medium grade ISI marked concealed in wallsurface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly, complete all as specified and directed.Note:- Two single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. 47 M&L Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round baras in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.(ii) Earthing wire beyond 7.5m shall be measured and paid separately. 48 B&R WorkM & L One closed side panel of ACP Sheet with framed Mild steel structure at one side of shed with the raised platform arrangement of size12m x 6m of brick work and Tile/marble flooring for Yoga / PT Shed, complete all as specified and directed. 49 M & L for Design, fabrication ,supply & erection of pre-engineered steel building incl civil works inside shed for One store Room of dimension 5 m x 5 m, complete all as specified and directed. 50 Material and Labour for 08 nos Rope Gallows made up of framed mild steel structure fixed to walls/floors with sliding arrangement which can be slided to one side when not in use with 5 ropes to be hung from each rope gallows including painting with primer, complete all as specified and directed. 51 Material and Labour for 04 nos beam bars made up of framed mild steel structure fixed to walls/ floors to be placed at one side of edge including painting with primer, complete all as specified and directed. 52 Material and Labour for 20 nos chin up bars made up of framed mild steel structure fixed to walls/ floors at 2.4m height fixed at one side of edge of shed including painting with primer, complete all as specified and directed. 53 Supply and fixing MS grill bars all around the shed, complete all as specified and directed. 54 EXTERNAL ELECTRIC SUPPLYSupply,installation and testing of factory made,CPRI Approved cubical outdoor (Kiosk) type feeder pillar box 415 volt, 4 wire, AC 50 Hz, made out of 3.15 mm thick CRCA sheet ,weatherand vermin proof powder coating finish bothside(interior & exterior) for outdoor mounting withhaving degree of protection as per IP-56 complete factory lock two earth terminal suitable cable gland for all incoming and outgoing and removable neutral link,Both Side openable double door Indicating light LED type RYB - 01 Set,Ammeter-01, Voltmeter-01, connecting strip/solid conductor brought out to cable chamber brass/copper nut, bolts/washer etc including grouting of feeder pillar box 60 cm above ground level including suitable size angle iron stand made up of65 x 65 x 6 mm welded on all the four corner embedded in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) upto 30 cm includingexcavation and earth work complete with following asseccories:-(a) copper insulatd busbar high conductivity 400 Amp rated 4 phase including neutral bus bar complete - 01 No.Incoming :-(b) MCCB4 -pole 160 Amp make-L & T,415 Volt,breaking capacity 36 KA,50 HZ with thermal magnetic release - 01 No.Outgoing :-(c)MCCB 4 - pole 125 Ampsbreaking capacity 25 KA, 50 HZ- 02 Nos. (d)MCCB 4 - pole 63 Ampsbreaking capacity 25 KA, 50 HZ- 01 No. 55 M&L for bus bar box of sheet metal 3 mm thick powder coated, having 4 Nos. aluminium bus bar of rating 200 Amp mounted on insulator including 01 No. of MCCB 4 pole 63 Amp 415 volts with thermal magnetic release as incomer, breaking capacity 25 KA inside the box and suitable fixing arrengement like flat iron clamp of size 25x3mm with hinged cover & locking arrangementincluding grouting of feeder piller box 60 cm above ground level by providing 90 cm long angle iron of size 40 X 40 X 6 mm welded on all the four corner embedded in PCC 1:2:4 using 20 mm graded stone aggregate complete duly painted with two coat of synthetic enameled paint over a coat of red oxide primer fixed in repair outdoor type duly fitted oncomplete all as directed by Engineer-in-charge. 56 Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable end termination heat shrink type joint complete with jointing material & accessories suitable for 3.5 core XLPEcable of size 16 sqmmto 35 sqmminsulated armoured aluminium cable complete all as specified and directed. 57 Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable end termination heat shrink type joint complete with jointing material & accessories suitable for 3.5 core XLPEcable of size 50 sqmmto 95 sqmminsulated armoured aluminium cable complete all as specified and directed. 58 Supplying ,laying, commissioning & testing 70 Sq.mm , 3.5 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking out old / unserveciable existing cablecomplete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. 59 Supplying ,laying, commissioning & testing 50 Sqmm , 3.5 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including takingout old / unserveciable existing cablecomplete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. 60 Supplying ,laying, commissioning & testing 35 Sqmm , 3.5 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking out old / unserveciable existing cable,complete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. 61 Supplying ,laying, commissioning & testing 25 Sqmm , 3.5 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking out old / unserveciable existing cablecomplete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. 62 Excavation in trenches, n. exc. 1.5 m wide and n. exc. 1.5 m in depth;for laying of cable, foundation, etc, or for shafts, wells, cesspits, manholes, etc. n. exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil,complete all as specified & directed. 63 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm,complete all as specified & directed. 64 Removing excavated material n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point,complete all as specified & directed. 65 M&L sand filling under floors or in foundations including watering and consolidation,complete all as specified & directed.Note :- Punned thickness shall be measured and paid. 66 Supplying & laying reinforced precast concrete cable cover, class EHV, type 1 with peak, size 450mm x 230mm x 50mm (Note: cable cover shall be laid perpendicular to the axis of cable). 67 M&L for earthing complete with galvanised steel earth plate 600 x 600 x 6.3mm burried directly in ground (Earth pit not less than 2.25 m deep) with top edge of the plate not less than 1.5 m below ground level connected to GI strip of size 32 x 6 mm by means of nuts, bolts & washers,earth wire protected by GI pipe 50 mm dia ‘light grade’ ISI marked including charcoal dust, common salt, excavation & earth work, PCC Pit with 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate),40 mm thick precast RCC cover in 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handles 12 mm dia, PGI funnel & GI watering pipe ‘light grade’ ISI marked, 20 mm bore all as shown in Electrical plate No. 03 of MES Schedule Part-1 (2009) complete. 68 M&L GI pipes/tubes 80 mm bore,light gradeincluding necessary GI Fitting i.e. GI bends with socket ,reducer socket laid in trenches fixed on pole fixed on walls UG Road/floor for cable protection complete,complete all as specified & directed. . 69 M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25x4mm galvanised iron strip,complete all as specified & directed. 70 Chain Link FencingExcavation in post holes (or similar holes) in soft/ loose soil each n exc 0.5 Cum filling in and ramming earth or broken rubble mixed with earth around, complete all speecified and as directed. 71 PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foudation for fencing post filling, and mass concrete, complete all as specified and directed. 72 Supply and Fixing Mild steel work Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed. 73 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire. 74 Supply chain link MS fencing galvanised mild steel wires 4mm diameter mesh size not less than 75mm x 75mm etc complete all as as specified and directed.
Contract Date: May 20, 2026 Contract Value : 5.24 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
30.
Power #11115939 Price Bid
Tender For Estimate For 11 Kv Interconnection Badodiya Agr Feeder Pachore S/S Under Gopalpur D/C Under Of (Oandm) Dn. Bhairunda - 140 Kg.,8.0 Mtrs. long PCC pole 2 WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 3 AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) 4 AAAC Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.) 5 M S Channel 100X50x6 mm 6 M.S.Angle 50x50x6 mm 7 M S Angle 65X65X6 mm 8 11 KV Pin Insulator Polymer Composit (5 KN) 9 11 KV Strain hardware (T&C type) fittings 10 11 KV(45KN) Composite Polymer Disc Insulators 11 G.I. Wire 3.15 mm. (10 SWG) 12 M.S.Flat 50x6 mm 13 Red oxide paint 14 Aluminium paint 15 Back filling of poles with boulders. 16 Carpet guarding 17 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 18 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 19 Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg) 20 Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) 21 Danger Boards Enamelled 11 KV 22 Danger Boards Enamelled 33 KV 23 M.S.Nuts with Bolts 24 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 25 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 26 Aluminium Binding wire and tape 27 Stay Insulators 90X65mm 28 MS strain plate 65x8mm 250mm long 29 STAY WIRE 7/4.00 MM.(7/8 SWG) 30 Stay set complete without Stay wire 16 mm. (Painted) 31 Stay set 20 mm. complete without Stay wire (Painted) 32 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 33 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 34 Concreting of structures & foundation (1:3:6) 35 Stone Block/Pre cast block for base pedding(450X450X75MM) 36 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 37 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 38 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal 39 GST on Transportation @5% 40 GST on (Contractor side Material + Labour) @18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
31.
Power #11115938 Price Bid
Tender For Estimate For 11 Kv Baifarcation Dimabar (Khadgaon) Agr Dlf Feeder Dimabar S/S Under Ladkui D/C Of (Oandm) Dn. Bhairunda - 140 Kg.,8.0 Mtrs. long PCC pole 2 WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 3 IRON STEEL SCRAP 4 ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) 5 AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) 6 Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) 7 Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) 8 Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) 9 Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured) 10 11 KV.C.Ts.(Outdoor dry type) 300-150/5-5 Amps 11 11 KV Single Phase PTs. (Resin Molded) 12 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel 13 11 KV control & relay panel with numerical static relay for double feeder protection 14 11 KV, ISOLATOR 800 AMP.(Turn and twist type) 15 11 KV AB Switch Porceline 400 Amp with Complete accessories. 16 11 KV Pin Insulator Polymer Composit (5 KN) 17 11 KV Strain hardware (T&C type) fittings 18 11 KV(45KN) Composite Polymer Disc Insulators 19 33 KV (45KN) Composite Polymer Disc Insulators 20 M S Channel 100X50x6 mm 21 M.S.Angle 50x50x6 mm 22 M S Angle 65X65X6 mm 23 G.I. Wire 3.15 mm. (10 SWG) 24 9 KV Gapless type(5 KA) polymer lightening arrestor 25 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems (For substation metering) 26 Red oxide paint 27 Aluminium paint 28 Back filling of poles with boulders. 29 M.S.Flat 50x6 mm 30 Carpet guarding 31 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 32 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 33 M.S.Nuts with Bolts 34 Danger Boards Enamelled 11 KV 35 Danger Boards Enamelled 33 KV 36 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 37 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 38 Aluminium Binding wire and tape 39 Stay Insulators 90X65mm 40 Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm 41 MS strain plate 65x8mm 250mm long 42 STAY WIRE 7/3.15 MM.(7/10 SWG) 43 Stay set complete without Stay wire 16 mm. (Painted) 44 Stay set 20 mm. complete without Stay wire (Painted) 45 Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) 46 Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer 47 Erection of Plinth per VCB- 33KV or 11KV 48 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 49 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 50 Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth 51 Concreting of structures & foundation (1:3:6) 52 G.I.Pipe 40 mm Dia C grade type 53 G.I. STRIP 25X3 MM1 54 Galvanized nut & bolt with washer 55 Bentonite compound powder 56 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor 57 Marshelling box with 10 no. connectors 58 SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB 59 Stone Block/Pre cast block for base pedding(450X450X75MM) 60 T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG 61 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 62 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 63 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal 64 GST on Transportation @5% 65 GST on (Contractor side Material + Labour) @18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
32.
Power #11115937 Price Bid
Tender For Estimate For 11 Kv Baifarcation Sonthiya Agr (Neelkanth) Feeder Neelkanth S/S Under Bhairunda D/C Of (Oandm) Dn. Bhairunda - IRON STEEL SCRAP 2 140 Kg.,8.0 Mtrs. long PCC pole 3 WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 4 H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-13 mtr. Long = 482.3 kg 5 ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) 6 (v) ACSR Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.), (6/4.72 + 7/1.57 mm) 7 AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) 8 11 KV Under-Ground XLPE armoured Cable 3X300 Sq.mm. 9 Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) 10 Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) 11 Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) 12 Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured) 13 G.I. Wire 3.15 mm. (10 SWG) 14 11 KV.C.Ts.(Outdoor dry type) 300-150/5-5 Amps 15 11 KV Single Phase PTs. (Resin Molded) 16 M S Channel 100X50x6 mm 17 M.S.Angle 50x50x6 mm 18 M S Angle 65X65X6 mm 19 M S FLAT 65X8 mm 20 11 KV, ISOLATOR 800 AMP.(Turn and twist type) 21 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel 22 11 KV control & relay panel with numerical static relay for double feeder protection 23 9 KV Gapless type(5 KA) polymer lightening arrestor 24 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems (For substation metering) 25 11 KV Strain hardware (T&C type) fittings 26 11 KV(45KN) Composite Polymer Disc Insulators 27 11 KV Pin Insulator Polymer Composit (5 KN) 28 33 KV (45KN) Composite Polymer Disc Insulators 29 SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB 30 Red oxide paint 31 Aluminium paint 32 M.S.Flat 50x6 mm 33 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 34 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 35 M.S.Nuts with Bolts 36 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 37 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 38 Aluminium Binding wire and tape 39 11 KV V cross arm 65X65X6 mm. angle type 40 Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg) 41 Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm 42 MS strain plate 65x8mm 250mm long 43 Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) 44 Danger Boards Enamelled 11 KV 45 Danger Boards Enamelled 33 KV 46 Stay Insulators 90X65mm 47 Back filling of poles with boulders. 48 STAY GI WIRE 7/4.00 MM.(7/8 SWG) 49 Stay set complete without Stay wire 16 mm. (Painted) 50 Stay set 20 mm. complete without Stay wire (Painted) 51 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 52 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 53 Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer 54 Erection of Plinth per VCB- 33KV or 11KV 55 Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth 56 Concreting of structures & foundation (1:3:6) 57 G.I. STRIP 25X3 MM1 58 G.I.Pipe 40 mm Dia C grade type 59 Galvanized nut & bolt with washer 60 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor 61 Stone Block/Pre cast block for base pedding(450X450X75MM) 62 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 63 Marshelling box with 10 no. connectors 64 Bentonite compound powder 65 Outdoor heat shrinkable cable end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 300 sq mm Latest applicable IS:13573/2011/Part-II with latest amendments 66 T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG 67 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 68 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal 69 GST on Transportation @5% 70 GST on (Contractor side Material + Labour) @18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
33.
Power #11115936 Price Bid
Tender For Estimate For 11 Kv Baifarcation Chhidgaon Agr Feeder Neelkanth S/S Under Bhairunda D/C Of (Oandm) Dn. Bhairunda - 140 Kg.,8.0 Mtrs. long PCC pole 2 WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 3 IRON STEEL SCRAP 4 ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) 5 (v) ACSR Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.), (6/4.72 + 7/1.57 mm) 6 AAAC Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.) 7 AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) 8 Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) 9 Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) 10 Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) 11 Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured) 12 G.I. Wire 3.15 mm. (10 SWG) 13 M S Channel 100X50x6 mm 14 M.S.Angle 50x50x6 mm 15 M S Angle 65X65X6 mm 16 M S FLAT 65X8 mm 17 11 KV Pin Insulator Polymer Composit (5 KN) 18 33 KV (45KN) Composite Polymer Disc Insulators 19 11 KV(45KN) Composite Polymer Disc Insulators 20 11 KV Strain hardware (T&C type) fittings 21 11 KV.C.Ts.(Outdoor dry type) 300-150/5-5 Amps 22 11 KV Single Phase PTs. (Resin Molded) 23 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel 24 11 KV control & relay panel with numerical static relay for double feeder protection 25 9 KV Gapless type(5 KA) polymer lightening arrestor 26 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems (For substation metering) 27 D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel 28 Red oxide paint 29 Aluminium paint 30 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 31 M.S.Nuts with Bolts 32 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 33 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 34 Aluminium Binding wire and tape 35 Back filling of poles with boulders. 36 Carpet guarding 37 11 KV V cross arm 65X65X6 mm. angle type 38 11 KV Bridling cross arms 65x65x6mm 39 Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg) 40 MS strain plate 65x8mm 250mm long 41 STAY GI WIRE 7/4.00 MM.(7/8 SWG) 42 Stay set complete without Stay wire 16 mm. (Painted) 43 Stay set 20 mm. complete without Stay wire (Painted) 44 Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) 45 Danger Boards Enamelled 11 KV 46 Danger Boards Enamelled 33 KV 47 M.S.Flat 50x6 mm 48 Stay Insulators 90X65mm 49 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 50 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 51 Erection of Plinth per VCB- 33KV or 11KV 52 Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer 53 Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth 54 Concreting of structures & foundation (1:3:6) 55 SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB 56 11 KV Under-Ground XLPE armoured Cable 3X300 Sq.mm. 57 Outdoor heat shrinkable cable end jointing kit with lugs for 11 kV grade XLPE cable for 3 core 300 sq mm Latest applicable IS:13573/2011/Part-II with latest amendments 58 T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG 59 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 60 G.I.Pipe 40 mm Dia C grade type 61 G.I. STRIP 25X3 MM1 62 Galvanized nut & bolt with washer 63 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor 64 Stone Block/Pre cast block for base pedding(450X450X75MM) 65 Bentonite compound powder 66 Marshelling box with 10 no. connectors 67 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 68 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal 69 GST on Transportation @5% 70 GST on (Contractor side Material + Labour) @18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Madhya Pradesh View Result →
34.
Power #11115935 Price Bid
Tender For Estimate For 11 Kv Baifarcation Chhidgaon Agr Feeder Bhadakui S/S Under Ladkui D/C Of (Oandm) Dn. Bhairunda - WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 2 IRON STEEL SCRAP 3 140 Kg.,8.0 Mtrs. long PCC pole 4 ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) 5 AAAC Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.) 6 AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) 7 Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) 8 Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) 9 Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) 10 Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured) 11 11 KV.C.Ts.(Outdoor dry type) 300-150/5-5 Amps 12 11 KV Single Phase PTs. (Resin Molded) 13 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel 14 11 KV control & relay panel with numerical static relay for double feeder protection 15 11 KV, ISOLATOR 800 AMP.(Turn and twist type) 16 9 KV Gapless type(5 KA) polymer lightening arrestor 17 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems (For substation metering) 18 M S Channel 100X50x6 mm 19 M.S.Angle 50x50x6 mm 20 M S Angle 65X65X6 mm 21 M S FLAT 65X8 mm 22 G.I. Wire 3.15 mm. (10 SWG) 23 11 KV Pin Insulator Polymer Composit (5 KN) 24 33 KV (45KN) Composite Polymer Disc Insulators 25 11 KV(45KN) Composite Polymer Disc Insulators 26 11 KV Strain hardware (T&C type) fittings 27 M.S.Flat 50x6 mm 28 Red oxide paint 29 Aluminium paint 30 Back filling of poles with boulders. 31 STAY WIRE 7/3.15 MM.(7/10 SWG) 32 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 33 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 34 M.S.Nuts with Bolts 35 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 36 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 37 Aluminium Binding wire and tape 38 Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg) 39 Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm 40 MS strain plate 65x8mm 250mm long 41 Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) 42 Danger Boards Enamelled 11 KV 43 Danger Boards Enamelled 33 KV 44 Stay Insulators 90X65mm 45 STAY GI WIRE 7/4.00 MM.(7/8 SWG) 46 Stay set complete without Stay wire 16 mm. (Painted) 47 Stay set 20 mm. complete without Stay wire (Painted) 48 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 49 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 50 Concreting of structures & foundation (1:3:6) 51 Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer 52 Erection of Plinth per VCB- 33KV or 11KV 53 Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth 54 G.I. STRIP 25X3 MM1 55 G.I.Pipe 40 mm Dia C grade type 56 Galvanized nut & bolt with washer 57 Bentonite compound powder 58 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor 59 Carpet guarding 60 Marshelling box with 10 no. connectors 61 SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB 62 Stone Block/Pre cast block for base pedding(450X450X75MM) 63 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 64 T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG 65 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 66 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal 67 GST on Transportation @5% 68 GST on (Contractor side Material + Labour) @18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
35.
Power #11115933 Price Bid
Tender For Estimate For 11 Kv Interconnection Pandagaon Feeder Under Gopapur D/C Under Bhairunda Dn - 140 Kg.,8.0 Mtrs. long PCC pole 2 WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 3 AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) 4 M S Channel 100X50x6 mm 5 M.S.Angle 50x50x6 mm 6 M S Angle 65X65X6 mm 7 11 KV Pin Insulator Polymer Composit (5 KN) 8 11 KV Strain hardware (T&C type) fittings 9 11 KV(45KN) Composite Polymer Disc Insulators 10 G.I. Wire 3.15 mm. (10 SWG) 11 11 KV AB Switch Porceline 400 Amp with Complete accessories. 12 M.S.Flat 50x6 mm 13 Red oxide paint 14 Aluminium paint 15 Back filling of poles with boulders. 16 Carpet guarding 17 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 18 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 19 Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) 20 Danger Boards Enamelled 11 KV 21 Danger Boards Enamelled 33 KV 22 M.S.Nuts with Bolts 23 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 24 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 25 Aluminium Binding wire and tape 26 Stay Insulators 90X65mm 27 MS strain plate 65x8mm 250mm long 28 STAY WIRE 7/3.15 MM.(7/10 SWG) 29 Stay set complete without Stay wire 16 mm. (Painted) 30 Stay set 20 mm. complete without Stay wire (Painted) 31 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 32 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 33 Concreting of structures & foundation (1:3:6) 34 Stone Block/Pre cast block for base pedding(450X450X75MM) 35 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 36 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 37 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
36.
Power #11115932 Price Bid
Tender For Estimate For 11 Kv Interconnection Badnager Feeder Under Gopapur D/C Under Bhairunda Dn. - WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 2 140 Kg.,8.0 Mtrs. long PCC pole 3 AAAC Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.) 4 AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) 5 M S Channel 100X50x6 mm 6 M.S.Angle 50x50x6 mm 7 M S Angle 65X65X6 mm 8 M S FLAT 65X8 mm 9 11 KV Pin Insulator Polymer Composit (5 KN) 10 11 KV(45KN) Composite Polymer Disc Insulators 11 11 KV Strain hardware (T&C type) fittings 12 G.I. Wire 3.15 mm. (10 SWG) 13 M.S.Flat 50x6 mm 14 Red oxide paint 15 Aluminium paint 16 Back filling of poles with boulders. 17 Carpet guarding 18 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 19 M.S.Nuts with Bolts 20 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 21 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 22 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 23 Aluminium Binding wire and tape 24 Stay Insulators 90X65mm 25 Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm 26 STAY GI WIRE 7/4.00 MM.(7/8 SWG) 27 Stay set complete without Stay wire 16 mm. (Painted) 28 Stay set 20 mm. complete without Stay wire (Painted) 29 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 30 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 31 Concreting of structures & foundation (1:3:6) 32 Danger Boards Enamelled 11 KV 33 Stone Block/Pre cast block for base pedding(450X450X75MM) 34 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 35 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 36 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal 37 GST on Transportation @5% 38 GST on (Contractor side Material + Labour) @18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
37.
Power #11115929 Price Bid
Estimate For 11 Kv Bifurcation Tiladiya Agr Feeder Rala S/S Under Bhairunda D/C Under Bhairunda Dn. - WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 2 140 Kg.,8.0 Mtrs. long PCC pole 3 IRON STEEL SCRAP 4 ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) 5 AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) 6 AAAC Rabbit conductor 0.05 sq. inch. (55 sq.mm. Al.Eq.) 7 XLPE Cable 1 core unarmoured 35 sqmm Aluminium conductor 1100 Volts 8 Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) 9 Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) 10 Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) 11 Copper Control Cable 12 Core. 2.5 Sq.mm. (Unarmoured) 12 G.I. Wire 3.15 mm. (10 SWG) 13 M S Channel 75X40x6 mm 14 M S Channel 100X50x6 mm 15 M.S.Angle 50x50x6 mm 16 M S Angle 65X65X6 mm 17 M S FLAT 65X8 mm 18 Stay Insulators 90X65mm 19 11 KV Pin Insulator Polymer Composit (5 KN) 20 33 KV (45KN) Composite Polymer Disc Insulators 21 11 KV(45KN) Composite Polymer Disc Insulators 22 11 KV Strain hardware (T&C type) fittings 23 11 KV Single Phase PTs. (Resin Molded) 24 11 KV.C.Ts.(Outdoor dry type) 300-150/5-5 Amps 25 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel 26 11 KV control & relay panel with numerical static relay for double feeder protection 27 11 KV, ISOLATOR 800 AMP.(Turn and twist type) 28 11 KV AB Switch Porceline 400 Amp with Complete accessories. 29 9 KV Gapless type(5 KA) polymer lightening arrestor 30 9 KV Gapless type ( 5KA) Polymer for DTR 31 11 KV D.O. Fuse Unit Polymer type 32 D.C. Cross-arms 8 ft centre to center (100x50x6mm) Channel 33 D.O.Mounting Channel 75x40x6mm 34 Three phase Static Energy meters 20-80 Amps.with L.S. & TOD Facility with box 35 3 phase 4 wire 3x63.5 volts lb=5 amps Imax = 10 amp, HT trivector meter class of accuracy 0.5s, DLMS Compliant category A Meters along with GSM (GPRS compatible ) modems (For substation metering) 36 Bi-metallic clamps suitable for 12mm dia stud and 80sqmm AAAC 37 Bi-metallic clamps Distribution Transformers Bushing 38 Red oxide paint 39 Aluminium paint 40 Back filling of poles with boulders. 41 M.S.Flat 50x6 mm 42 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 43 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 44 M.S.Nuts with Bolts 45 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 46 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 47 Aluminium Binding wire and tape 48 Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm 49 Clamp for 140 Kg PCC Pole MS Flat 50x6 mm 50 MS strain plate 65x8mm 250mm long 51 STAY WIRE 7/3.15 MM.(7/10 SWG) 52 STAY GI WIRE 7/4.00 MM.(7/8 SWG) 53 Stay set complete without Stay wire 16 mm. (Painted) 54 Stay set 20 mm. complete without Stay wire (Painted) 55 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 56 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 57 Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) 58 Danger Boards Enamelled 11 KV 59 Danger Boards Enamelled 33 KV 60 G.I. WIRES 4.0 MM. (8 SWG) 61 Carpet guarding 62 Erection of Plinth per VCB- 33KV or 11KV 63 Stringing of Each 11 KV Bus-upper and lower bus including, drop jumpering and jointing with clamps,through outgoing VCB/ ME/ DP, upto station transformer 64 Complete jumpering of DTR 65 Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth 66 Concreting of structures & foundation (1:3:6) 67 G.I. STRIP 25X3 MM1 68 G.I.Pipe 40 mm Dia C grade type 69 Bentonite compound powder 70 Galvanized nut & bolt with washer 71 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor 72 Stone Block/Pre cast block for base pedding(450X450X75MM) 73 Marshelling box with 10 no. connectors 74 SHEET METAL METER BOX SUITABLE FOR H.T. STATIC TRAVECTOR METERS WITH TTB 75 Meter cum protection box for 25 KVA DTR 76 T CLAMP FOR 33KV & 11KV BUS, SUBSTATION upto DOG 77 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 78 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 79 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal 80 GST on Transportation @5% 81 GST on (Contractor side Material + Labour) @18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
38.
Tourism #11114098 AOC
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. B) All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 40 Kg / Cm2 (Wire Cut Bricks) In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry Usign Fly Ash Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) With Bricks Of Class Designation 40 Kgs / Cm2. Above Plinth Upto Floor V Level 200 X 95 X 95 , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) With Usage Of Ordinary Portland Cement Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continuous Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineerin-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc. Moulding As In Cornices, Window Sills Etc. Exceeding 15 Cm In Girth. , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates Cornices & Mouldings , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4b Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint. B) In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing & Fixing Upvc Door Frame Yashashri Make Or Equivalent Made Out Of Upvc Extruded Multi Cavity Frame Of 60 Mm X 60Mm X 2Mm Wall Thickness. Frame Is Reinforced With G.I. Channel & Welded In Corners With Average Weight 0.80 Kg Per Running Mtr. These Frames Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing & Fixing 20 Mm Door Shutter Yashashri Make Or Equivalent, Made By Using 20Mm X 155Mm X 1.2Mm Upvc Multi-Cavity Section And Boarder Of 30Mm X 40Mm X 2.5Mm Upvc Multi Cavity Section. The Corners Are Joined By Inserting Polymetric Corners & Hardware Used For Fixing The Door Shutter Is Stainless Steel Hinges & S. S. Handle & S.S. Tower Bolt. The Average Weight Of 20Mm Door Shutter Is 4.60Kg Per Sq Mtr. These Upvc Sections Are Tested By Using Bs 2782 & Din 53459 Test Methods. , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete 250 X 16 X 5 Mm , Providing & Fixing Bright Finished Stainless Steel Ss 304 Grade Aldrops With Screws Etc. Complete. 250 X 150Mm. All Works Complete As Per The Drawing, Specification And Direction Of The Engineer-In-Charge-In-Charge , Providing And Fixing Stainless Steel D Type Handles With Necessary Screws Etc Complete A) L 300Mm/325Mm X 22 To 25Mm Dia , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete 125 X 70 X 4.0Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 200 X 10 Mm , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete 150 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete A) Dark Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. C) 80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.D) 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 60 Mm Thick In Grey Colour (M35 Grade) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm A) Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) 20 Mm Thick. , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Approved Make And Colour With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 150 Mm Strip Between Five Stone For Grassing.Strips To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.( Price Including Stone, Gardening Soil, Fertilizer And Grass Etc. ) , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete. 140 Mm Nominal Size , Extra For Providing Flat Iron Bracket 50 X 3 Mm Size Instead Of 40 X 3 Mm Size With Necessary Bolts Nuts, Washers Etc. For Fixing A.C. Gutters To Purlins. , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters. 140 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Of Flashing Tape Along Wall And Tile Jointes ( Abutment Area ) Including Fixing Of Aluminium Strip Above Flash Including Sealing The Top Edge With Uv Resistant Sealant Etc Complete. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Mts. Lead. , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Carting Away Unwanted Excavated Material Such As Soil, Lime, Moorum, Building Rubbish, Laterite Stone, Excavated Earth, Ordinary Rock Etc. From Site Lead Of 5 Km Including All Loading & Unloading Charges ( A ) ( By Mechnaical Automative Transport ) Contractor Should Arrange Land For Dispose Up These Material At His Own Cost Lead Upto 5 Km. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. , Supply, Fabrication And Installing In Position Ms Gates Of Required Width And Height Of Including Wicket Gate And Rolling Gate(If Necessary) Of Approved Size Made Of Channels Joists, Angles, Plates, Pipes And Ms Sheets Including Stiffeners, Bracing, Fabricated Hinges, Ms Aldrops Locking Arrangement, Tempered Steel Pivots, Guide Track Of Ms Tee, Ball Bearing Arrangement, Casters Wheels Etc. All Complete As Per Drawing, Specification And As Directed By Engineering In Charge All Complete. The Main Entrance Gate Shall Be Fabricated Out Of Mild Steel Sections Completed With Applying A Priming Coat Of Approved Steel Primer And Two Coats Of Synthetic Enamel Painting. The Structural Steel Works For Gates Shall Include Supply, Fabrication, Transportation, Erection Of Structural Steel Gates Complete With Placing In Position Embedded Parts In Concrete / Brickwork And In Road Surface Including Cutting, Grinding, Drilling Of Holes, Welding And Painting Etc Complete , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. : , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge A) 110 Mm Dia , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. Size 900 X 400 X 100 Mm With Steel Reinforcement Not Less Than 5.0 Kgs Per Unit -12 T Capacity , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. A) Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. B) Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. C) Theming Work For Nandi Kalash In Frp As Per Tender Drawing , Construction Of Deepstambh Of Reinforced Cement Concrete Pillar With Exposed Laterite Masonary Of Octagonal Shape (1500Mm Length Of Each Side And Total Height Of 5500Mm) With Openings For Placing Diya Lamps And Foundation Platform Of Size (1800Mm Length Of Each Side And Height Of 1500Mm) Including Molding,Etc. As Per The Detail Drawings And As Directed By Engineer In Charge. , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Rough Dressing The Trenched Ground Including Breaking Clods. , Fine Dressing The Trenched Ground. , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Of Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevatia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Sebestena , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Foxtail Palms , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Callistemon (Bottlebrush Tree) , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size (3.0 M To 4 M Ht.) Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Mimusops Elengi , Plumbing Works , Proving And Fixing White Vitreous China Wall Hung Type (European Type) Water Closet With Seat And Lid With C.I. Brass Hinges And Rubber Fittings With Flush Valve Nelson/ Similar Fully Chromium Plated With Stop Cock, Wall Flanges, Flush Pipe Or Elbow And Vaccum Breaker Coupling Etc. Including Chair Bracket/Rag Bolts, Cutting & Making Good The Walls And Floors Where Required And Concealed Seat Support - W.C. Pan With White Plastic Seat And Lid , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Large Lipped Front Urinal Basin Of 590X375x390mm Size With Urinal Valve Auto Closing System With Built In Control Cock & Wall Flange With Fittings, Spreader, R.S. Or C.I. Brackets, Standard Size C.P. Brassl Flush Pipe And Spreaders With C. P. Brass Unions & C. P. Brass Clamps With Waste Fitting As Per Is 2556, Pvc Trap With Outlet Grating And Other Couplings In Cp Brass Complete, Including Painting, Fittings, Cutting And Making Good The Walls And Floors Where Required. - Range Of One Urinal Basin , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed : 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75 Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand ;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 90 X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Light Duty) 455 X610mm Internal Dimensions Total Weight Of Cover Ad Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg. ) , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:. 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 32Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work.Sch-40(Blue)/(White) 50Mm Outer Dia , Providing And Fixing Non-Return Valve Of Approved Quality : 40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality Low Pressure With Copper Floats 25 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 20 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : 25Mm Outer Dia. , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc25 Mm , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete 150 Mm , Conveying Carefully From Stack At Site, 250M From Both Sides Rolling And Lowering Into Trenches, Laying And Jointing True To Line And Level, Reinforced Cement Concrete Spun Pressure And Non Pressure Pipes Of Various Classes, Specials Including Collar And Perfect Linking Of Joint With Jack To Correct Position Including Cost Of Jointing Material In Cement Mortar 1:2, Necessary Hydraulic Testing, Curing Of Cement Mortar Etc. Complete. 150 Mm , Providing And Fixing Angular Stop Cock With Wall Flangue - Jaquar Make. Florentine (Flr-5053N) 15Mm Of Approved Quality. , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996 1000 Lit. Capacity , Supply Of Inferential, Dry Dial, Type Domestic Water Meter,Suitable For Horizontal Installation, Duly, Sealed Against Tampering With Couplings At Both Ends Having Pulse Output Facility Compatable For Automatic Reading System ,Conforming To Is:779-1974 And Iso 4064-2005 Standards And Bearing Eec/Mid/Oiml Mark, (With Latest Amendments)Along With Test Certificate From Fcri/Nabl As Desired By The Department.25 Mm , Fixing Water Meter & Stop Cock In G. I. Pipe Line Including Cutting & Treading The Pipe And Making Long Screw Etc. Complete (Cost Of Water Meter And Stop Cock To Be Paid Separately) , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality : 15 Mm Nominal Bore , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 60 To 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of Architectural Designed Pole Of 3Mtr Height Post Top Pole Made Of Galvanised Iron Sections Of 114Mm & 60Mm Dia. This Architecturally Designed Pole Is Structurally Sound. Windspeed Considered Should Be As Per Is875:Part 3:1987 ,Material For Tubes Steel Of Grade Yst210.,Material For Base Plate Steel Of Grade E250 To Is2062; 2011. The Pole Will Be Provided With An Inbuilt Junction Box To Fix 16-32Amp Connectors & 6-16Amp Mcb Inside The Cut Window Of The Bottom Pipe The Inbuilt Box Should Have A Flush Door Of Suitable Size With Allenkey Locking On Bothside. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 200X200mm Having 10Mm Thickness. The Base Plate Shall Have 4 Hole Suitable For M16/450 Foundation Bolts . The Galvanized Zinc Coat Should Not Be Less Than 65+/ 10Microns. The Galvanised Pole Should Be Painted In 3Layer Coating (Coating Thickness Should Not Be Than 80Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint With Overall 100 +/- 10 Microns. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation,Testing & Commisioning Of 40-50W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40-45W Led. Fitting Shall Be Post Top Mounting Type Fixture. System Wattage: 40-45W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply, Led Lumens:6000Lm, Cri(Ra):80, Led Colour Temperature: 4000K, Life Span:60,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv . Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Pf=0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -5 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (A) 5 To 20 A , Supply Of 3 Kva 3 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board Consumer Unit 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Hinged Front Acrylic Cover For The Mcb Knobs Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (B) 2 + 8 Way Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. B) Dp, Cat A , Supplying And Fixing Following Rating Double Pole (Single Pole And Neutral) 240 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required (A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying & Erecting Of Led 12W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A
Contract Date: Jul 02, 2026 Contract Value : 3.70 Crore
Government Departments No of Bidders 2
39.
Defence #11110287 Technical Bid
Tender For Provision Of Md Accommodation For 16 X Officer At Ferozpur Mil Stn (Tender-1) (Tender Id : 2025_Mes_742975_2)- 3 Lump Sum Price Worked Out By The Contractor For Building Work As Listed In Schedule A Part-I Brought Forward From Serial Page No.30. 4 Lump Sum Price Worked Out By The Contractor For Site Clearance And Earth Works As Listed In Schedule A Part-Ii Brought Forward From Serial Page No.31. 5 Lump Sum Price Worked Out By The Contractor For Internal Electrification Works As Listed In Schedule A Part-Iii Brought Forward From Serial Page No. 32, 33(R) To 35(R). 6 Lump Sum Price Worked Out By The Contractor For Internal Water Supply Works As Listed In Schedule A Part-Iv Brought Forward From Serial Page No. 36(R). 7 Lump Sum Price Worked Out By The Contractor For Sewage Disposal Works As Listed In Schedule A Part-V Brought Forward From Serial Page No. 37. 8 Lump Sum Price Worked Out By The Contractor For Area Drainage Works As Listed In Schedule A Part-Vi Brought Forward From Serial Page No. 38. 9 Lump Sum Price Worked Out By The Contractor For Compound Wall Fencing And Gate Works Listed In Schedule A Part-Vii Brought Forward From Serial Page No. 39 & 40. 10 Lump Sum Price Worked Out By The Contractor For Road, Path & Culvert Works As Listed In Schedule A Part-Viii Brought Forward From Serial Page No. 41 & 42. 11 Lump Sum Price Worked Out By The Contractor For External Water Supply Works As Listed In Schedule A Part-Ix Brought Forward From Serial Page No. 43. 12 Lump Sum Price Worked Out By The Contractor For External Electrification Works As Listed In Schedule A Part-X Brought Forward From Serial Page No. 44 To 47. 13 Lump Sum Price Worked Out By The Contractor For Dg Set Work As Listed In Schedule A Part-Xi Brought Forward From Serial Page No. 48. 14 Lump Sum Price Worked Out By The Contractor For Lift Work As Listed In Schedule A Part-Xii Brought Forward From Serial Page No.49. 15 Lump Sum Price Worked Out By The Contractor For Fire Fighting, Fire Alarm & Detection System Work Works As Listed In Schedule A Part-Xiii Brought Forward From Serial Page No. 50 & 51. 16 Lump Sum Price Worked Out By The Contractor For Lightening Protection Work As Listed In Schedule A Part-Xiv Brought Forward From Serial Page No. 52. 17 Lump Sum Price Worked Out By The Contractor For Rain Water Harvesting Works As Listed In Schedule A Part-Xv Brought Forward From Serial Page No. 53 & 54(R). 18 Lump Sum Price Worked Out By The Contractor For Solar Water Heater Work As Listed In Schedule A Part-Xvi Brought Forward From Serial Page No. 55. 19 Misc Items Of Works (To Be Quoted By Bidder) As Listed In Schedule A Part-Xvii 20 Internal Water Supply Works 21 Supply & Fixing 15Mm Cp Brass Health Faucet (Hand Shower), Inlet Length 100Mm Fixed To Angle Valve With And Including Decorative Choice Flexible Pipe, Wall Hanger Etc Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. 22 Supply & Fixing 15Mm Bore Fancy Type Central Hole Single Lever Basin Mixer With 450 Mm Braided Connection Pipe Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed.Make Cera Model No F2013451 / Jaquarqqp‐Chr‐7167Bpm / Roca T5A8497Ca1 / Kohler Model No. K‐ 27484In‐4‐Cp 23 Supplying And Fixing Two Way Bib Cock With Single Handle And Wall Flange 15Mm Dia, Fancy Type Chromimum Plated Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. Make Cera Model No F2013163 / Jaquar Lyrchr‐38041 / Kohler Model No K‐16094In‐4‐Cp / Roca Model No.Rt5A937Aca1 24 Supply & Fix 15 Mm Bore Sink Mixer With Swinging Spout (Wall Mounted) With 150Mm Long Swivel Spout Connecting Legs & Wall Flanges Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. Make Cera Model No F2013501 / Jaquar Model No Ari‐Chr‐39165 / Kohler Model No. K‐20591In‐4‐Cp / Roca Model No. Rt5A8497Ca1 25 Supplying And Fixing Wall Mounted Bib Cock, Chromium Plated, With Wall Flange & Aerator (Cera Cat No. F1015151) / Jaquar‐ 16094In‐4‐Cp/ Roca Rt5A937Aca1 / Kohler Model No 16093In‐4‐Cp Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. 26 Supplying And Fixing 32 Mm Upvc Ball Valve With Screwed Both Ends Pipe And Fixed All As Specified And Directed 27 Internal Electrification Works 28 Material & Labour For Point Wiring With 1.5 Sqmm, Pvc Insulated But Unsheathed, Stranded Copper Conductor Single Core Frls Cable, Is-694 Marked, Drawn Through And Including Non Metallic Rigid Pvc Concealed Conduit Medium Grade 20Mm Dia (Minimum) Or Higher Size As Specified And Cutting Chasing On Wall Complete With All Pvc Conduit Accessories Such As Socket, Elbow, Junction Box, Bell Mouth, Reducer, Bend And Flexible Conduit Etc/ Fittings Isi Marked For Modular Fittings And Brass Screws And Cup Washers Including 1.5 Sqmm Stranded Copper Conductor Pvc Insulated Frls Cable Green In Colour As Continuous Earth Conductor Connected To Common Earth And Earth Dolly With All Accessories Complete All As Specified And Directed. Note:- Cost Of Metal Boxes And Modular Accessories Like Cover Plates Will Be Paid Seprately In Respect Items (A) Fan Point/ Exhaust Fan Point /One Light Point/Bell/Buzzer Controlled By One Switch/Bell Push. 29 (B) One Modular Socket Outlet 5 Pin 5 Amp Controlled By One, One Way Switch On Same Board. 30 (C) One Modular Socket Outet Point 5 Amps On The Independent Board. 31 (D) One Light Point Controlled By Two Nos Of Two Way Switch. 32 All As Ser Item 4.02 Here In Before But With 2.5 Sq Mm Wire And Earth Wire Of 2.5 Sq Mm For 3 Pin 15 Amp Modular Type Socket Outlet. 33 Supply And Fix Modular Metal Flush Box Made Out Of Gi Sheet, Thickness Not Less Than 1.2Mm With Earthing Terminal, 8 Module Complete All As Specified And Directed. 34 Supply And Fix Modular Metal Flush Box Made Out Of Gi Sheet, Thickness Not Less Than 1.2Mm With Earthing Terminal, 12 Module Complete All As Specified And Directed. 35 Supply And Fix Modular Dummy Plate Complete All As Specified And Directed. 36 Supply And Fix Led Energy Efficient Led Bulb B22, 9 Watt Complete All As Specified And Directed. 37 Supply And Fixing Vtpn Db’S 4 Way, Double Door, 415V, Ip43, Suitable Size And Length Of Crca Steel Sheet, Dust Protection Duly Powder Painted Including Factory Fitted Suitable Size Copper Bus Bar, 01 No Of Mccb Tpn As Incomer And 04 Nos Tp As Outgoing With Neutral Link, Earth Bar, Din Bar For Mounting Mcb And Blanking Plate A Complete All As Specified And Directed. Note:- Mcb Shall Be Measured And Paid For Separately. 38 Supply And Fixing Tv Socket And Connector Complete With All Necessary Fittings All As Specified And Directed. 39 Material & Labour For Wiring With 1100 Volt Grade One Single Core Frls Wire Pvc Insulated And Unsheathed Cable With Stranded Copper Conductor 1.5 Sqmm (For Inverter) Drawn Into Pvc Conduit With All Accessories Fixed Concealed Complete All As Specified And Directed. 40 Supply And Fix Led Tube Light Fitting In Extruded Aluminium Housing For All Purpose Surface And Wall Mounted With Single Side Connection Aluminium Led Batten With 125 Lum/Watt System Efficancy Polycarbonate Housing And Integrated Electronic Driver Of Capacity 20 W, Four Feet And Connection With Pvc Insulalted Twin Core 23/0.0076 Twisted Copper Cable From Ceiling Rose To Tube Light Fitting Complete All As Specified And Directed. Make: Havells Cat Part No. Enduralinearprobs20Wled865Spcssind Or Equivalent Make Of Bajaj/Crompton/ Philips. 41 Supply And Fix Wall/Ceiling Mounting Led 9/10 Watt Tube Light Fitting In Extruded Aluminium Housing And Integrated Electronic Driver Complete With All Acessories 1X9 Watt Led, With Cct Of 6000K Suitable For Domestic Application, 240 Volts, 50 Hz, And Internally Pre-Wired With 1.5 Sqmm Twin Twisted Flexible Cable Copper Conductor And Connection Complete All As Specified And Directed. Make: Havells Cat Part No. Lumilinebs9Wled865Spcwh Or Equivelent Make Of Bajaj/ Crompton/ Philips. 42 Supply And Fix Bldg Street Fitting Made Up Of Pressure Dai Cast Aluminum Housing With High Efficiency Leds As A Lighting Source And Lens Embedded Pc Cover Having Top Oppening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07, Cct 5700 K, Of Wattage 25 Watt Including Connection With 3 Core Pvc Insulated Overall Sheathed Flexible Cable With Multi Stranded Copper Conductor Of Size Not Less Than 1.0 Sq Mm From Celing Rose To Fitting Terminal All As Specified And As Directed. Make :- Havells/ Bajaj/ Hpl/Philips 43 Supply And Fix Gi Pipe Bracket Made Of Gi Pipe Light Grade 32Mm Dia And Bend To Shape 1.5 Mtr Long Ms Clamp Made Out Of Ms Flat Iron Of Size 32Mm X 3Mm With Nut And Bolts Washer Complete Including Drilling Of Holes For Nut And Bolts Etc Complete All As Specified And Directed. 44 Supply And Fixing Decorative Type Led Wall Lights Fitting 08/09 Watt, 220V, Suitable For Led Lamp B22 9 Watt Complete All As Specified And Directed. Make: Havells Cat No Lhfoecce1Tz1O014 Or Equivalent Philips/Cg 45 Supply And Fix Kitchan Wall Fan 300 Mm Sweep, 1350 Rpm, Of Elegantly Designed Fan Base In Round Shape For 50 Cub Mtr/Min Air Delivery And Minimal Noise Levels With Pull Code Control For Speed & Oscillation Upto 90 Degree Total Flexibility, Double Z Shielded Ball Bearing, Sturdy Brazed Wire Guards With Power Coating Ensures Corrosion Resistance Conforming To Is 2997-1964 Complete All As Specifed And Directed. 46 Supply And Fix Kitchan Chimney Dry Heat Auto Clean Technology Stainless With Air Outlet 150 Mm, Steel Finish Front Matte Black Glass Panel With Digtal Display Touch Control Panel With 3 Speed Gesture Motion, Heavy Duty Baffle Filters, Minimium Air Flow 1180 M3/H Energy Saving Led Light Of Suitable Wattage, Copper Winding Bldc Motor, 62Dba Max Noise Level And Voltage 220-240 V/50 Hz Including Making Hole In The Wall And Making Good The Distubed Surface Of Wall Including All Accessories All As Specified And Directed. Make : Kaff Model No.Sku Nevishc90 Or Eqvt In Hindware/ Faber. 47 Supply, Installation, Testing & Commissioning Of 3-Φ, 4 Wire, Ac Static Direct Connected, Smart Pre-Paid Energy Meters, Isi Marked Of Different Makes As Per Bis-16444, With Communication Technology Including Gprs/Rf/Hybrid (Rf Mesh Network+Gprs)/Any Other Advanced Technology As Per Cea/Trai Regulations) With Current Range 10-60 Amp, 415 V, Accuracy Class 1.0 Uc1 Category And Above Along With In-Built Load Control Switch, Containing Provision For Tod & Rtc, Capable To Define Multiple Tariff Slabs Complete All As Specified And Directed.Meter Should Support The Following Data:- (I) 15 Min Instantaneous Data For Voltage, Current, Power Factor, Power, Cumulative Energy And Frequency, Daily And Monthly Billing Survey For Cumulative Energy And Max Demand(Ii) Meter Should Have Connect / Disconnect Functionality Operable For Mdm/Billing Software And Prepaid Features Would Be Operable For Mdm / Billing End As Per Is: 15959 Part-2.(Iii) Meter Should Support Communication Protocol Through Rf/ 5G/4G/Nb Iot With The Existing Software In Stn All As Required At Site And Directed (Cost Of 5G/4G/Nb Iot Sim With Two Year Recharge Facilities, Mapping, Vending Portal Charges Etc Deemed To Included In Rate Quoted For Meter). (Iv) The Meter Should Support Open Communication Protocol Dlms With The Existing Software.Make: Anchor/L&T/Hpl/Secure.Note:- (I) The Smart Meter Would Be Compatiable With Existing Software/Dcu In Stn.(Ii) The Rate Of Sim As Well As Data Pack Of 24 Months From Date Of Completion For Connectivity Is Deemed To Be Including In The Quated Rates. 48 Supply & Fixing Of Transparent Polycarbonate Meter Box Of Suitable Size With Ip-54 For 3-Φ, 4 Wire, Smart Energy Meter Mentioned Here-In-Above At Sch. Item No. 4.21. The Polycarbonate Meter Box Shall Comply With Is-14772:2000 And Is-11000:1984. It Shall Be Totally Shock Proof, Safe Weater Proof, Rust Roof, Dust Proof, Water Proof, Halogen Free, Silica Free And Having Internally Embeded Gasket Technology, Transparent Hinged Lid And Sealing Provision Including Bakelite Connector, Complete All As Specified And Directed. Make: Anchor By Panasonic/L&T/ Hpl/Secure. 49 Road Works 50 Material And Labour For Preparing Bituminous Surface Of Road And Marking 2.5Mm Thick Hot Applied Thermo Plastic Road Marking Paint Of Approved Colour Providing Retroreflecting Glass Beads @ 250 Gm Per Square Metre As Per Irc-135 With Special Applicator Machine All As Per Manufacturers Instruction Complete All As Specified And Directed. 51 External Water Supply Works 52 Supply And Laying Ductile Iron Pipe Of 100Mm Bore With Spigot And Socket Ends Centrifugally Cement Mortar Lined Complete As Per Is 8329/ 2000 Class K-9 With Including Suitable For Tyton Joint And Jointing Material/ Joints Laid In Trenches Complete All As Specified And Directed.Note ;- Di Specials And Earth Work Shal Be Measured And Paid Seperately. 53 S&F 80Mm Dia Gi Tubing Heavy Grade C Class With All New Connections And Fitting Such As Tee, Elbows, Bend, Reducer, Unions, Short Pieces, Connector Back Nuts, Diminishing Pieces, Caps, Plugs Unions Etc Laid In Threnches Complete All As Specified And Directed. 54 Material & Labour For Valve Pits And Constructing Of Brick Masonary Pits Of Internal Dimensions 900Mm X 900Mm X 900Mm (Bottom Pcc Floor Of The Pit Should Be Minimum 30 Cms Below The Bottom Surface Of Sluice Valve Flange To Provide Sufficient Working Space), Bottom Floor Of The Pit Be Constructed In Pcc (1:3:6) 51 Cms Thick With 20 Mm Stone Aggregate, Inner And Exposed Surfaces And Bottom Floor Of The Pit Should Be Plastered In Cm (1:4) 15 Mm Thick. The Sluice Valve And Other Fittings Should Be Housed In Center Of The Pit. The Verticesof The Pit Should In Right Angle And Champhered. The Top Cover Of The Pit Will Be Made Out Of Ms Sheet Min 2 Mm Thick With Angle Iron Frame Made Out Of Ms Angle 50Mm X 50Mm X 6Mm With Galvanized Steel Hindges Two Nos And Locking Arrangements Duly Painted With Two Coats Of Water Resistant Synthetic Enamelled Paint Over One Coat Of Red Oxide Complete All As Specified And Directed. 55 Material And Labour For Taping From Existing Di 80 Mm To 150 Mm Including Cutting, Jointing, Inserting Tee And Alll Accessories Complete All As Specifed And Directed.Note:- Tee Shall Be Measured And Paid Separately Under Respective Items. 56 External Electrification Works 57 Supply, Install, Testing And Commissioning Of Lt Distribution Panel (Cpri Type Tested ) Cubicle Type Ip-65, Outdoor Type Confirming To Is-61439 Factory Fabricated Prewired Made Out Of 3.15 Mm Thick Crca Sheet Outer & 2 Mm Thick Crca Sheet Inner Of Suitable Size To Accommodate All Accessories/Fittings Compartmentalized In Construction To Accommodate The Incoming/Outgoing Mccb And Tpn Bus Bars And Outgoing Feeders. The Tpn Bus Bars Shall Be Insulted With Colour Coated Heat Shrinkable Sleeve And Shall Be Mounted On Dmc Support. The Incoming As Well As Outgoing Mccbs Shall Have Extension Links Of Current Carrying Cap Not Less Than 1.5 Times The Rated Capacity Of Individual Feeders. The Extension Links Shall Be Supported On Dmc Support Having Provision For Termination Of Incoming And Outgoing Cables. All Extension Links/ Interconnections Shall Be Colour Coated Sleeves. The Cubicle Shall Have Frame Work At Bottom Of Ms Channel Mc 100 Fixed To The Top Of Plateform. The Plateform Of Lt Panel Shall Be Pedestal Type Of Suitable Width And 600 Mm Height Above Ground Level And Minimum 400 Mm Below The Ground Level Constructed With Bricks (Sub ClassB) Work Duly Plastered In Cm 1:3 And Pcc Copping (1:2:4) Not Less Than 50 Mm Thick Over Brick Pedestal With Adequate Opening For Entry Of Cable Complete As Per Manufacture Recommendation And Directed By The Engr-In-Charge. A Detachable Gland Plate Of Thickness Not Less Than 3 Mm Thick Should Be Used At The Bottom For Entry Of Armoured Cable Of Adequate Size Compression Glands, The Panel Shall Be Painting With Powder Coated Finish With Ral 7032 Siemens Gray Structure After Seven Tank Phosphate Treatment Front & Back Opening Type And Fixing 2 Nos Danger Notice Plan With Letter Figures And Conventional Skull Bones In Signal Red Colour And Fixed Front & Back Door To Lt Panel With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Shall Have Louvers And Air Vent Gasket For Natural Flow Of Air Neoprene Adhesive Type Gasket Shall Be Used To Make Panel Vermin Proof And Comprising Of Following:- Please Enable Macros To View Boq Information 58 Supply, Install, Testing And Commissioning Of Lt Distribution Panel (Cpri Type Tested ) Cubicle Type Ip-65, Outdoor Type Confirming To Is-61439 Factory Fabricated Prewired Made Out Of 3.15 Mm Thick Crca Sheet Outer & 2 Mm Thick Crca Sheet Inner Of Suitable Size To Accommodate All Accessories/Fittings Compartmentalized In Construction To Accommodate The Incoming/Outgoing Mccb And Tpn Bus Bars And Outgoing Feeders. The Tpn Bus Bars Shall Be Insulted With Colour Coated Heat Shrinkable Sleeve And Shall Be Mounted On Dmc Support. The Incoming As Well As Outgoing Mccbs Shall Have Extension Links Of Current Carrying Cap Not Less Than 1.5 Times The Rated Capacity Of Individual Feeders. The Extension Links Shall Be Supported On Dmc Support Having Provision For Termination Of Incoming And Outgoing Cables. All Extension Links/ Interconnections Shall Be Colour Coated Sleeves. The Cubicle Shall Have Frame Work At Bottom Of Ms Channel Mc 100 Fixed To The Top Of Plateform. The Plateform Of Lt Panel Shall Be Pedestal Type Of Suitable Width And 600 Mm Height Above Ground Level And Minimum 400 Mm Below The Ground Level Constructed With Bricks (Sub ClassB) Work Duly Plastered In Cm 1:3 And Pcc Copping (1:2:4) Not Less Than 50 Mm Thick Over Brick Pedestal With Adequate Opening For Entry Of Cable Complete As Per Manufacture Recommendation And Directed By The Engr-In-Charge. A Detachable Gland Plate Of Thickness Not Less Than 3 Mm Thick Should Be Used At The Bottom For Entry Of Armoured Cable Of Adequate Size Compression Glands, The Panel Shall Be Painting With Powder Coated Finish With Ral 7032 Siemens Gray Structure After Seven Tank Phosphate Treatment Front & Back Opening Type And Fixing 2 Nos Danger Notice Plan With Letter Figures And Conventional Skull Bones In Signal Red Colour And Fixed Front & Back Door To Lt Panel With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Shall Have Louvers And Air Vent Gasket For Natural Flow Of Air Neoprene Adhesive Type Gasket Shall Be Used To Make Panel Vermin Proof And Comprising Of Following:- Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
40.
Power #11108394 Price Bid
Tender For Estimate For Conductor Aug. Work At 33 Kv Godrej Feeder Originated From 132 Kv Ehv S/S Mandideep - WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 2 H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-15 mtr. Long =565.5 kg 3 ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) 4 M S Channel 75X40x6 mm 5 M S Channel 100X50x6 mm 6 33 KV Pin Insulator Polymer Composite (10 KN) 7 33 KV (45KN) Composite Polymer Disc Insulators 8 33 KV Strain hardware (T&C type) fittings 9 Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 8 ft (2.4 mtr ) centre DP 10 Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 5 ft(1.5 mtr) centre DP 11 Back Clamps for H-Beam of MS Flat 65x8mm (Each weight 1.92 Kg) 12 MS strain plate 65x8mm 250mm long 13 Clamp 65X8 mm Flat of MS Flat for H-Beam ( Each weight 3.2 kg) 14 Red oxide paint 15 Aluminium paint 16 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 17 M.S.Nuts with Bolts 18 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 19 Aluminium Binding wire and tape 20 Danger Boards Enamelled 33 KV 21 STAY GI WIRE 7/4.00 MM.(7/8 SWG) 22 Stay set 20 mm. complete without Stay wire (Painted) 23 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 24 Concreting of structures & foundation (1:3:6) 25 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor 26 Single Suspension Strain Set for ACSR Panther Conductor 27 Stone Block/Pre cast block for base pedding(450X450X75MM) 28 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 29 Dismentelling 30 Additional Erection Charge 31 IRON STEEL SCRAP (Return Material Side to Area store Bhopal) 32 CONDUCTOR ACSR SCRAP(Return Material Side to Area store Bhopal) 33 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 34 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
41.
Defence #11104420 AOC
Tender For Repairs / Re-Novation Of Ofti And Ofti Work Shop Buildings Inside Factory Area At Ofmk.; 1 Site clearence 2 FELLING OF TREE: Felling of tree exc.30 cm and not exc.100 cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50m and clearing site 3 GRUBBING UP TREE TRUNK : Grubbing up tree trunk of girth exceeding 100 mm and not exceeding 150 mm, including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable materials and removing of unserviceable materials to a distance n. exc. 50 m and clearing site. 4 Demolition of cement concrete of any description and in any position not otherwise specifically provided for.Complete all as specified directed. 5 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar. Complete all as specified directed. 6 Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. Complete all as specified directed. 7 Dismantling floor,heartor wall tiling including cement mortar bedding but nor baking removing serviceable tiles to stores and rubbish off the premises.Complete all as specified directed and directed. 8 Taking down : Taking downcement or cement lime plaster, any description on brick or stone walls, etc.including raking out joints, hacking for key, scrubbing down with water, etc. 9 Removing building materials etc.other than spoilupto a distance of 1.0 Km, including loading, unloading and stacking at the destination. 10 Brick work with sub class ‘B’ bricks straight or curved in plan with 1:6 cement mortar.Complete all as specified and directed. 11 Stone Masonry : Walling of Squared Rubble regular coursed Stonemasonry, well bonded, bedded and solidly hearted built in with 1:6 cement mortar, Complete in all respects as specified and directed. 12 Damp proof course to horizontal or vertical surfaces In cement concrete 1:2:4, type B-0, 40 mm thickincluding necessary formwork . 13 Flush Pointing with 1:4 cement mortar to square rubble, coursed, well bonded and solidly hearted built in cement mortar as directed. 14 Vitrified tiles : Supply and laying of Light shade vitrified tiles 10 mm thick (Square/Rectangle) polished , area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Floor tile finishglossy/mat/ antiskid will be as decided by EIC. Complete all as specified and directed . Make : Johnson, Orient bell, AGL as approved by EIC. 15 GRANITE : S&F Granite 25 mm thk (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Complete all as specified and directed. 16 FLOOR TILING :Supply & fixing Coloured non skid ceramic tiles in flooring, 7 to 8 mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell 17 SCREED BED : Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with cement mortar 1:6. Complete all as specified and directed. 18 Plastering : Rendering of 10mm thick plastering with 1:6 cement mortar on fair faces of brick work or concrete surfaces. Complete in all respects as specified and directed. 19 Rounding to edges of stone slabs / granite one edge,such as in steps, cooking platform, and other similar situations. Complete all as specified and directed. 20 Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets etc. complete as directed by EIC. 21 Taking down wooden wall panelling of any description and similar work as directed. 22 Snap grid : Supply and fixing of 605x605 mm snap gridGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners withand including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediatechannel with connecting clips across the intermediatechannel at 457 mm centre to centre. Complete all as specifiedand directed, Make : Armstrong 23 Supply and fixing of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified. 24 POP ceiling : Providing 10 mm thick plaster of Paris(gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mmwith 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately). Complete all as specifiedand directed, Make : Armstrong 25 Ceiling board : (M&L) S&F Exposed metal frame ceiling with calcium silicate boardof siliceous and calcareous material reinforced with cellulose fibre / PVC laminated gypsum tiles with MPL film on rear side, 8 mm thk.for fixing in 600 mm x 600mm grid,Make: Gyproc/ La gyp 26 Door shutter repair : Taking down door shutter of any description exc. 1 sqm and not exc. 2 sqmand repairing and adjusting to the required size including fixing builders hard ware and refixing to the same opening. complete all as specified and directed. 27 Dismantlingof structural steel work including doors, gates, but excluding framed truss etc. Complete all as specified directed. 28 UPVC window / Ventelator : Supply and fixing factory made UPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension . Complete all as specified and directed. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, 29 UPVC window : Three track three panels sliding window with fly proofS.S wire mesh (Two nos. glazed & one no. wire meshpanels) upto 1.50m height made of (big series) frame116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extrudedinterlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy bodywith single nylon rollers (weight bearing capacity tobe 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steelscrews etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, including drillingof holes for fixing hardwares and drainage of wateretc. After fixing frame the gap between frame andadjacent finished wall shall be filled with weatherproof silicon sealent over backer rod of required sizeand of approved quality, complete all as specified anddirected by Engineer-in-Charge. 30 UPVC door : Supply and fixing factory made uPVC white colour Three track three panels sliding door with fly proofS.S. wire mesh (Two nos. glazed & one no. wire meshpanels) made of (big series) frame 116 x 45 mm & sash46 x 82 mm both having wall thickness of 2.3+ 0.2 mm and single glazing bead/ double glazingbead of appropriate dimension. (Area of door above2.00 sqm upto 5.00 sqm) comprising of uPVCchambered frame, with in-built roller track and sashextruded profiles duly reinforced with 1.60 + 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionuPVC extruded glazing beads, uPVC extrudedinterlock and uPVC extruded Inline sash adaptor (ifrequired), EPDM gasket, wool pile, zinc alloy (whitepowder coated) handle with key on one side of extremepanels along with zinc plated mild steel multi pointlocking having transmission gear with keeps, zincalloy (white powder coated) cresent lock (if required).stainless steel (SS 304 grade) body with adjustabledouble nylon rollers (weight bearing capacity to be120 kg), G.I fastener 100 x 8 mm size for fixing frameto finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut andfusion welded at all corners, including drilling ofholes for fixing hardwares and drainage of water etc.After fixing frame the gap between frame and adjacentfinished wall shall be filled with weather proof siliconsealent over backer rod of required size and ofapproved quality, complete all as specified anddirectd. 31 steel wire cloth : Supplying and Fixing in repairs stainless steel wire cloth0.36mm nominal dia.(Guage 28) of wire and width of aperture 1.4mm to wooden / steel doors/ windows, including fixing with and necessary screws, nut bolts,nails and removal of existing damaged cloth etc., complete all as specified and directed 32 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.0 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 33 Sheet glass : Supply and fixing of Sheet glass, ordinary quality 4.8 mm thick and glazing with oil putty in squareexc 0.5 sq. m in each pane. Complete all as specified and directed by EIC. 34 Wooden Wall panelling : S & F of Prelaminated particle board18/19 mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work. Complete as specified and directed at site. 35 Wooden panelling frame work : S&F of battens frame work using wooden clean sawn 2nd class soft wood battens of cross sectional area exc. 15 & not exc. 25 sq.cm at a spacing of 35 centres. Complete as specified and directed at site. 36 PCC paving : PCC 1:4:8 in floors/ pavingoftype D-2, 1:4:8 with 40mm graded aggregate,100 mm thick.Complete all as specified and directed. 37 Earth work in excavation in all kind of soils by mechanical means (Hydraulic excavator) means over areas exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge 38 Soling (or sub base) of spread thickness 150 mm with broken boulders or quarried stone, inter sticesfilled, surface formed and rolled and consolidated torequired gradient and camber. Complete all as specified and directed. 39 Hard core with broken stone/boulders of gauge not exc. 63mm, deposited, spread leveled in layers not exceeding 15 cm thick, and watered consolidated to required gradient & camber including watering. Complete all as specified and directed. 40 Moorum filling in floors or pavings laid in layers not exe. 15cm thick , spread leveled and rammed including watering. Complete all as specified and directed 41 Stone sett flooring (M&L) with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 42 Edge stones to flooring (M&L) with stone setts of size 250 to 300mm long x l50 to 200mm wide, and 450mm deep and and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush. Complete all as specified and directed. 43 PCC paving : PCC 1:2:4 in floors/ pavingoftype B-2, with 40mm graded aggregate, 100 mm thick. Including finishing concrete surface even and smooth surface without using extra cement.Complete all as specified and directed. 44 Wearproof topping 20 mm thick using CC 1:2:4, as specified incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner). Complete all as specified and directed. 45 Supply of metalic floor hardener 46 Surface excavation not exceeding 30 cm deepand averaging 20 cm deep in hard / dense soil and getting out. Complete all as specified and directed 47 PCC FLOORING : Cement concrete of 100 mm thickness in floors, sub-floors, sub-bases, pavings etc. oftype B-1, 1:2:4 (20 mm graded aggregate) 48 Smoth finish : Finishing cement concrete surface even and smooth using extra cement. 49 CC Paver blocks : S&F of Machine pressed precastconcrete interlocking paver block any shape and sizeconfirming to IS 15658-2006 of 60 mm thickness, M-35Grade with grey cement & pigment (Coloured)Complete all as specified and directed. 50 CC chequered tiles :S&F of cement concrete chequered tiles with grey pigment cement and pigments(Coloured tiles) for pavements. size of tile 20cm x20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors.Complete all as specified and directed. 51 PCC paving : PCC 1:3:6 in floors/ pavingof type C-2, with 40mm graded aggregate, 100 mm thick.Complete all as specified and directed. 52 Forming 12mm thick Expansion joints for 100 thick slabsfilled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A. ’ Complete all as specified and directed. 53 Structural steel (S&F) : Structural steel work confirming to Fe-410 W (Gde-E-250) quality-A Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled forfixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, including application of one coat of Zinc chromate primer paint .Make:TATA, Jindal 54 Structural steel (S&F) : Structural steel work Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Steel confirming to Fe410W (Gde E-250 quality A). Make : TATA, Jindal, Complete all as specified directed. 55 Structural steel (S&F) : Mild steel bolts. purpose made. of dia. of neck n.exc. 12 mm with hexagonal orsquare head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long. Complete all as specified directed. 56 Roofing sheet : Supply and fixing of pre painted galvalume aluminium zinc coating GI basedcorrugated/ trapezoidal profile roofing sheets of thickness 0.5 mm having tensile strength of 550Mpa as in roof covering / cladding to wall with self tapping screws etc. Make : TATA / Jindal /Essar. Complete all as specified and directed. 57 Supply only of liquid water proofing compound for incorporating concrete.Make. Fosrac, BASF, SIKA 58 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in in lintels upto 1.5m clearspan, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating. complete as specified and directed. 59 Kerb stone : Providing precast cement concrete using Type-B1, 1:2:4 20 mm graded aggregatein window or doorcills, lintels, bressumers, steps, quoin blocks (for use with ma- sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets,etc. with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar 1:4. Complete with joints to match . Complete all as specified and directed. 60 PCC : Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate)in roofkerbs or mud stops, rounded orchamfered on edges.complete as specified and directed. 61 PCC : Plain Cement Concrete (1:2:4) Type B2 using 40 mm graded aggregate in foundations, floors, filling and mass concrete, Complete all as specified and directed . 62 RCC : Reinforced cement concrete (Type B1, 1:2:4 with 20 mm aggregates) in columns, pillars, piers, posts etc. Complete all as specified and directed. 63 REINFORCEMENT : Mild steel(TMT) bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specified and directed. . 64 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 100 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 65 SWG PIPE : Supply & fixing of 100 mm dia Salt Glazed Stoneware drain pipes Grade A, including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 66 CEMENT CONCRETE BEDDING (M&L) : Providig Cement concrete bedding for Drain Pipes of internal dia 150 mm with PCC 1:4:8, type D2 including forming cradles etc. Thickness of PCC bed is 100 mm and width 400 mm complete all as specified and directed. 67 SWG PIPE : Supply & fixing of 150 mm dia Salt Glazed Stoneware drain pipeslaid in trenches including laying in proper slopes, including jointing with cement and jute complete all as specified and directed. 68 Earth work in excavation of all kind of soils by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Complete all as specified and directed . 69 Returning, filling in of excavated soils, including spreading, levelling, watering and well ramming in layersnot exc 25 cm. 70 PVC PIPE : Supply and Fixing of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid or fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 71 PVC PIPE : Supply and Fixing of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls including necessary jointin with connected accessories like T, Y junctions, sockets, bends etc. complete all as directed. Make: Sudhakar/ Nandi/ Supreme. 72 Cutting chases in brick wall, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit iring, etc., and making good, cutting not exc 10 cm girth. Complete all as specified and directed. 73 Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat surfaces. Complete all as specified and directed. 74 S & F ofG.I. Tubes of Size 40 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 75 S & F ofG.I. Tubes of Size 25 mm dia, medium grade including all fittings to walls and ceilings or in floors/trenches. 76 S & F ofG.I. Tubes of Size 1/2‘’(15 mm), medium grade including all fittings to walls and ceilings or in floors/trenches. 77 Supply & Fixing Rotational moulded polyethylene water storage tanks (PVC cylindrical vertical with closed top) hoisted and fixed in position 1000 lit capacity. make : Syntex 78 BALL VALVES : 25 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. Complete all as specified and directed. 79 NAHANI TRAPS : Supply & Fixing ofCI Nahani traps 100mm with grating including jointing to went pipe with CC 1:2:4complete all as specified and directed at site. 80 GULLY TRAP : M&L for PVC/SWR gully traps, of size 125 mm x 110 mm all as directed and specified. 81 GRATING : Supply and fixing of grating doom 100 mm dia. of PTMT (min. weight 25 gms) 82 PVC D/E PIPE CONNECTION :Supply and fixing of PVC Double End Pipe connection.in repairs, size:15mm with end nuts & washers of length 600 mm. Make : Kohinoor. Complete all as specified and directed. 83 ALUMINIUMPARTITIONS : Supply and fixing complete of anodised aluminium powder coated frames for partition frames and windows etc. all complete as directed by E.I.C. 84 ALUMINIUM WINDOW SHUTTERS : Supply and fixing complete of anodised aluminiumwindow and ventilator shutters powder coated fixed type without sash bar ,aluminium section weighing 0.55 kg/m including necessary jointig cleats, glazing clips, rubber neoprane packing, handles 2 nos. in each door, hinges, anodised aluminiumsnap beading, screws etc. complete all as directed by E.I.C. 85 HINGES : Supply and fixing of extruded Al. alloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-21 of size 125mmincluding all as specified and directed . 86 Antique aldrop : Supply and fixing of 200 mm long Antique model Brass mixed heavy alloy, sliding door bolt withsand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed.All as specified and directed and as approved by EIC. 87 Brass hinge: Supply and fixing of extruded brassalloy with GI Mild Steel Hinge Pine anodised Butt Hinges and fixed typeB-11 of size 125mmincluding.All as specified and directed and as approved by EIC.. 88 Antique tower bolt : Supply and fixing of Antique model Brass mixed heavy alloy, barrel tower bolts of extruded section of size 200 mm and fixed all as directed.All as specified and directed and as approved by EIC. 89 Antique Door handle : Supply & fixing of Extruded Antique model Brass mixed heavy alloy, cast type polished bright handles 150 mm long, Complete all as specified and directed 90 TOWER BOLT : Supply and fixing of Aluminium anodised, barrel tower bolts of extruded section of size 200 mm and fixed all as directed. 91 BOW HANDLE: Supply & fixing of Extruded aluminium alloy handles 150 mm long, fabricated type, anodised. Complete all as specified and directed 92 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be easured separately), removing materials to store for keeping in safe custody for reuse at site and making good. 93 Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) 94 point wiring:S&F / Drawing of cables in PVC pipe,OneLight point or onefan point controlled by one switch with cables 1.5 sq.mm size of copper conductor cables FR PVC single core sheathed cable 95 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 5 amps independent, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 96 point wiring: S&F /Drawing of cables to One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size of copper conductor cables FR PVC sheathed. 97 point wiring: S&F / Drawing of cables in PVC pipe, One 3 pin socket outlet 15 amps independent, with cables 4.0 sq.mm size of copper conductor cables FR PVC sheathed. 98 S & F of ceiling rose,3 phase/PVC/Polycorbonate, Isolate body 99 S & F ofswitch modular type of one module, 6 amps 100 S & F ofsocket, 2/3 pin combined, 6 amps, 2 Module 101 S & F ofswitch modular type of one module, 16 amps 102 S & F ofsocket, 2/3 pin combined, 16 amps, 2 Module 103 S & F ofFan step regulator 120 W, 2 Module 104 LED LUMINAIRE :Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/ Halonix 105 S & F of round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. 106 S & F of LED tube lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 107 LED Street Light :Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Philips/CG/Wipro/ Osram/ Havells/ Orient/Halonix.complete all as specified and directed 108 Exhaust Fan: Supplyand Fix Exhaust Fan made of sturdy Engineering plastic complete with Lauvers, Shutteers, voltage 230 V,50 HZ, RPM 1200, Copper winding ofsweep 250mm.complete all as specified and directed. 109 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) 110 Industrial socket plug: Supply and fixing of 240 V, 20 amps, single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB. 111 MCB :Supply and fixing of MCB / Isolator, 240 V, single pole 40 amp 112 MCB :Supply and fixing of MCB / Isolator, 240 V, double pole 40 amp 113 MCB D.B : S & F of Sheet Metal enclousers for D.B ofsingle doorof SPN,8 way with 200A rated bus bar,240V 114 MCCB: Suppply and fixing of MCCB 3 pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA. 115 S & F of Modular metal flush box 6 module 116 S & F of Modular white cover plate with frame 3 module 117 S & F of Modular white cover plate with frame 4 module 118 S & F of Modular white cover plate with frame 6 module 119 S & F of Modular white cover plate with frame 8 module 120 EARTHING : Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth lead GI strip 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.complete all as specified and directed 121 Earth continuity conductor : Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip. complete all as specified and directed 122 Dismantlng ofAsbestos cement (corrugated,semi corrugated, etc.) sheets in roofcoverings. Sheets shall be deposited to stores as directed. 123 Cutting or uprooting grass on old CC/brick tiles or on old mud phuska,and Taking down old Taf felt and loose material from the roof, cleaning the bitumen surface by wire brushing, washing down & disposing the pealed off tar felt muck etc. for complete as directed. removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster. Complete as specified and directed. 124 Surface painting : Removal of old tarfelt sheets,Wire brushing and cleaning top surface of roof tops and surface painting, with a layer of bitumen primer for bitumen membrane @ 0.50 ltr/sqm by the same membrane manufacturere of density at 25° C, 0.87-0.89 Kg/ltr and viscosity 70-160 cps and then left the surface 4 to 8 hours for drying.Complete as specified and directed. 125 Bitumen Tack coat / Seal coat : Applying surface bitumen coat Seal / Tack coatwith lndustrial bitumen 85/25 forwaterproofingtreatments at the rate of 1.2 kg / sqm . 126 Water proofing treatment (M&L) : Rendering water proofing treatment to RCC roof slabs including vertical surfaces with APP based polymetric membrane sheet, minimum 3 kg/sqm and minimum 3.0 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) evenly laid on primed surfaces by forced applicationby torch on treatment. The vital physical and chemical parameters of the membrane shall be : Tensile strength in longitudinal and transverse direction at 23° C as 650/450/5 cm.Tear strength in longitudinal and transverse direction as 300/250 N. Softening point of membrane not less than 150° C. Cold flexibility shall be up to 2° c when tested in accordance with ASTM, D-5147. The laying of membrane shall be done through the authorised applicator of the manufacturer of membrane. Membrane make : STP / Dr. Fixt / IWL as approved by EIC. 127 Carrying and disposal of debris : Removing building materials etc. to a distance of 1.5 KM or under including loading, unloading and stacking at the destination. Complete all as specified and directed at site. 128 Rolling shutter : S&F ofSteel rolling shutters 1.25 mm thickness of lathe, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle. Complete all as specified and directed. 129 Rough excavation notexceeding1.5 m deepin drains etc in loose/soft soils andgetting out 130 Scarifying : Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area not exc.400 sqm and the thickness Exc 50 mm and n.exc 100 mm deep 131 Preparing unsurfaced water bound macadam surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 132 Macadam : Premix bituminous, macadam with paving bitumen any penetration laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less).Complete all as specified and directed. 133 Pot holes : Repair to pot holes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth,making good by applying tack coat @ 5 kg per 10 sq m, putting in premixed bituminous macadamusing paving bitumen, well rammed and sealed with binder 9.8 kg per 10 sq m, blinded with 0.09 cu m of stone chippings,6.3 mmsizeand again well rammed (including supply of premixed macadam, binder and chippings). depth of potholes exc 30 mm.Complete all as specified and directed. 134 Preparing Black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc.Complete all as specified and directed. 135 Applying evenly a priming/tack coat with bituminous primer using paving bitumen at 5kg per 10 sq metre. Complete as specifiedand directed. 136 Bituminous premixed carpet, 2.5 cm consolidated thickness, with 0.34 cu.m. of stone chippings mixed with 18.25 kg of binder (paving bitumen)per 10 sq.m and mixed in mechanical hot mix plant and laid with mechanical paver and rolled using power roller 8-10 T capacity and compacted to required camber and gradient to uniform smooth surface. Complete as specifiedand directed. 137 Supply and fixing of Machine cut cudappah stoneslab 20-25mm thick over cementscreed base, laid and jointedwith grey cement slurry mixedwith pigment to match the shadeof the slab including rubbingand polishing complete. 138 Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint and application of priming paint plaster coat. 139 Rendering synthetic enamel painting on new Steel surfacesof any description over 10 cm width or girth- TWO coats including one coat of red oxide Zinc chrome paint. Make: Asian paints/Berger 140 Complete removal existing treatment of of white washing onsurfaces of walls/ concrete. 141 Complete removal existing treatment of of white washing on surfaces of ceilings. 142 CHALK WHITENING : M&L - Chalk whitening (white cement-based, water-resistant, white wall putty) of plastered surfaces as preparatory to distempering on wall surfaces, Make : Birla wall care, complete all as specified & directed. 143 PRIMER : Priming plastered and other surfaces with alkali resistant priming paint. Make : Asion/Dulux- all as specified and directed . 144 WHITEWASH ON CEILINGS : M&L - White washing on ceilings- on old decorated surfaces- including preparation of surfaces – ONE coat of White Wash-complete all as directed. 145 WHITEWASH ON WALLS : M&L - White washing on Walls – on old decorated surfaces- including preparation of surfaces - TWO coats of White wash - complete all as directed. 146 PLASTIC EMULSION PAINT:Rendering plastic emulsion painting on old surfaces- including preparation surfaces on walls- TWO coats of plastic emultion paint-complete all as directed. Make: Asian -Apcolite / Dulux-promise. 147 OBD : M&L - Rendering Oil Bound Distempering on old surfaces -including preparation of surfaces on walls - TWO Coats of OBD - complete all as directed. Make : Asian-tractor Uno / Berger-Butterfly / Indigo-gold. 148 External weather proof painting on walls : Material & Labour for applying Two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfaces. all as specified and directed, Brand : Asian apex,Berger weather shield, Nerolac Rain coat. 149 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting onOld painted Steel surfaces- surfaces of any description over 10 cm width or girth including preparation of surfaces-TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 150 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on Old painted Steel surfaces- surfaces of any description n.exc 10 cm width or girth including preparation of surfaces- TWO Coats- all as specified and directed- Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 151 ENAMEL PAINTING : M&L - Rendering synthetic enamel painting on wooden surfaces - old surfaces of any description over 10 cm width or girth including preparation of surface - TWOCoats- all as specified and directed-Make: Asian-Apcolite / Berger-Luxol / Dulux-Glass. 152 FRENCH POLISHING : French polishing on old surfaces of any description, width or girth –including cleaning and preparing the surface- One or more coats. all as specified and directed. Make : Sheenlac, sealer 153 Supply and fixing of Safety lever locks mild steel with 4 levers for rolling shutters as directed. 154 Fan Hook: Supply and Fixing of Fan hook with double anchor bolt complete fixing as per instructions of EIC. 155 IWC : IWC of approved make fixed with P trap Make: Hindware/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 156 CONCEALED FLUSHING SYSTEM : Wall mounted concealed flushing system (including frame, control plate and installation kit) with dual flush mode of capacity 10 ltrs. Make: Jaquar(Solo)/ Parryware(Prime)/ Cera(Fountain). Complete all as specified and directed. 157 MIRROR : Mirror 5 mm thk. with bevelled edge fixed with concealed screws Make: Saint Gobain/ Nilkamal/ Casa Gold. Complete all as specified and directed. 158 Switch board box with frame plate and cover plate , metal flush box18 module: Supply and Fixing of covering plates with Metal Flush box andcover plate frames of 18 module of make Legrand/ Schneider/ Havellscomplete all as specified by the EIC 159 Concertina coil & 6 straight RBT strands : Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina cross type fencing, GI steel plate & GI core wireon wall top using concertina coils stretched to approx.6 meters length at site and clipped with three nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as C clips, R.B.T clips etc.). Including additional three horizontal R.B.T strands to be fixed with vertical portion of MS angle supports as directed in site. Complete all as specified and directed at site. 160 Accoustic sheets : supply and fixing of choice colourPolyester Fiber Acoustic Board / tiles, Thickness: 12mm, for insula-tion and accoustic purposes, 60x60 cm in size, fixed to wall / ceiling surfaces on snap grid orwith nails to timber frame work or with Z bar/clips etc as specified by manufacturer.Complete all as specified and directed. 161 Floor mat: supply and fixing of choice colourNylon carpet for floors minimum 6 mm thicknesshaving better accoustic co-efficient ,fixed to floor with approved adhesiveas specified by manufacturer.Complete all as specified and directed. 162 ACP wall lining : Supply and fixing of decorative choice colour solid finished Aluminum composit panel 4.0 mm thick sheeting on external wall surfaces upto 12.0 mter heights fixed over aluminium/MS framed wall surfaces as specified by manufacturer. Cost includes ACP panel, frame work, jointing glue and scafolding etc. Complete all as specified and directed. 163 UPVC window (Single glazed panel shutter & fixed wire mesh panel): Supply and fixing factory made uPVC white colour Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series)frame 47 x 50 mm & sash 47 x 68 mm both havingwall thickness of 1.9 ± 0.2 mm and single glass paneglazing bead of appropriate dimension (Area ofwindow upto 0.75 sqm.) comprising of uPVC multi-chambered frame, sash and mullion (where everrequired) extruded profiles duly reinforced with1.60 ± 0.2 mm thick galvanized mild steel sectionmade from roll forming process of required length(shape & size according to uPVC profile), uPVCextruded glazing beads of appropriate dimension,EPDM gasket, stainless steel (SS 304 grade) frictionhinges, zinc alloy (white powder coated) casementhandles, G.I. fasteners 100 x 8 mm size for fixingframe to finished wall, plastic packers, plastic capsand necessary stainless steel screws etc. Including SS wire mesh panel with aluminium beeding fixed to outer face window using adjustable /removable clips. Profile offrame & sash shall be mitred cut and fusion weldedat all corners, mullion (if required) shall be alsofusion welded including drilling of holes for fixinghardwares and drainage of water etc. After fixingframe the gap between frame and adjacent finishedwall shall be filled with weather proof siliconsealant over backer rod of required size and ofapproved quality, complete all as specified anddirected by Engineer-in-Charge. 164 WALL TILES : Supply & fixing of Coloured digital glazed ceramic tiles in vertical surface 300x600 mm set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed. Make: Johnson/ Kajarai/ Orient Bell. 165 PVC door frame : S & F of solid WPVC Door Frame of size 100x60 mm heavy density of 11100 kg/cum and high quality PVC laminated of choice colour. Complete all specified and directed. 166 PVC door shutter : S & F of Factory Made Solid WPVCDoor Shutter with wood free EPS, 32 mm thick, heavy density 700 kg/cum and high quality PVC laminated on both side of choice colour. 167 Staircase railing : Supply and fixing of designed Stainless steel hand railing not less than 0.8 mtr height for stairs, balconies etc. using SS grade 304/316 members for balusters & rails etc. and covered with 12 mm thick tampered toughned glass. Design & model shall be as decided by EIC. Cost inclusive of glass, design and other mountings. Complete all as specified and directed. 168 Handicap grab bar : S&F of stainless steel anti slip vertical swing handicap bath room grab bar/rail with paper holder of min. 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 169 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 1.0 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 170 Handicap grab bar : S&F of stainless steel anti sliphandicap bath room grab bar/rail of 0.45 mtr long. including all necessaryt fitting accessories Make : Jaquar, Hindware as directed.Complete as specified and directed at site. 171 Wood Door : Supply and fixing of modern & designer soildTeakwood door shutters for Main Doors 32 mm finished thickness as decided by EIC . 172 EWC : Supply and fixing ofItalian Collection ceramic Floor Mount Western Commode, Rim less, One-piece for Bathrooms with Syphonic vortex Flushing system and soft closing seat cover including connection pipe.Make : Jaquar Fusion, Hindware Fabio, Cera cinova 173 WASH BASIN : Supply and fixing of Under counter Wash basin rectangle of approved make along with waste coupling, waste pipe and connection pipe, brackets etc. Make : Jaquar(Continental)/ Cera(campa)/ Parryware(Aqiline). Complete all as specified and directed. 174 URINAL : Supply and fixing ofSensor Urinal pan of approved make with auto flushing system including connection pipe, waste coupling and waste pipe Make: Jaquar(Aquisense)/ Parryware(Prime)/ Cera(Clair). Complete all as specified and directed. 175 PILLAR COCK : S&F ofsensorbased table top model Pillar cock with auto closing system of make: Jaquar / Hindware/ Cera. Complete all as specified and directed. 176 CONCEALED STOP COCK : S&F of CP Concealed stop cock of make : Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 177 2 WAY ANGLE COCK : S&F ofCP 2 way angle cock Make: Parryware(Uno)/ Cera(Fountain)/ Jaquar(Solo). Complete all as specified and directed. 178 EWC JET FAUCET : S&F of EWC jet faucet of make: Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 179 BIB COCK : S&F ofCP Bib cock of make: Jaquar(Solo)/Parrywaare(Uno)/ Cera(Fountain). Complete all as specified and directed. 180 SOAP DISH : S&F of SS soap dish of make Jaquar(Solo)/ Parryware(Uno)/ Cera(Fountain). Complete all as specified and directed. 181 Hand drier: Supply and fixing of plastic Automatic Hot air drierfor bath rooms of approved make. Make :Orchid / Dolphy / Bajaj. Complete all as specified and directed. 182 Liquid soap dispensar: Supply and fixing of Liquid soap dispensar for bath rooms of approved make. Make :Jaquar / Orchid / Dolphy. Complete all as specified and directed. 183 Toilet paper holder: Supply and fixing of stainless steel single toilet paper roll holder of approved make. Make :Jaquar continental / Parryware sigma/ Cera Icon. Complete all as specified and directed. 184 Urinal partition : Supply and fixing of HPL (High-Pressure Laminate) urinal partitions using 12 mm thick compact board of width 400 to 500 mm and height 1200 mm of approved make and fixing with stainless steel brackts. Complete all as specified and directed. 185 Bldg.Expansion joint : Preparation of joint by grinding of groove surfae, remoal of dust, providing polymer mixed cement mortar on both sidea of groove and crack filling if any in floor level, fixing of baker rod 25x25 mm to control depth of groove, Providing and applying Nitoseal PU50 of Fosroc or equivalant having MAF 25% or above to the groove 25x12 mm. Including fixing / covering of joint with APP based polymetric membrane sheet sufficient width. Complete all as specified and directed at site. 186 Forming V grooves on granite surfacesn,exc 10mmdeep and n exc 10mm on face in steps, cooking platform, and other similar situations etc. 187 Hiring / Engage of JCB for cleaning, moving and loading materials like sand, gravel, or demolitionand removal of debris and other miscellaneous purposes as directd. The rate includes diesel and driver required to run the vehicle. 188 Carpet grass : Supplly and laying of carpet grass on levelled soil surface including preparing the soil bedby loosning the base ground 100 mm thick and removing old unwanted grass if any and necessary watering as directed. 189 Supply and laying of red earth / soil in loose state which is free from debris, grass and other vegitation to be used for gardening purposes as directed. 190 Architectural design : Before commencement of work Contractor should take architectural consultancy servies for entrance arch at the entrance gate, building front elevations and garden designs by authorised institutions / authorised Designer. Complete all as directed by EIC
Contract Date: May 16, 2026 Contract Value : 3.98 Crore
Government Departments No of Bidders 4
42.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
43.
Tourism #11085444 Technical Bid
Tender For Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer. , Supplying And Filling Moorum In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Laterite Masonry In Neatly Dressed Stones For 23 Cms Thick Masonry Walls In C.M. 1 : 4 (1 Cement : 4 Coarse Sand In Foundation Upto Plinth Level Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Half Brick Masonry In Cement Mortar 1:3 (1Cement : 3 Coarse Sand) With Bricks Of Class Designation 75 Kg /Cm2. B. Upto Floor V Level. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level M-30Grade Of Concrete , Centering And Shuttering Including Strutting, Propping, & Removal Of Form For Foundation, Footings, Bases Of Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs, Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) , Providing Tmt Steel Reinforcement Bars Of Sail, Tata, Vizag Made Only (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. Minimum Grade Of Steel - Fe 500 , Steel Work Welded (Sail, Tata. Vizag & Using Electrodes Of Ador Or Es4B Or Deh Secheron Make Only)In Built Up Sections Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying Priming Coat Of Red Lead Paint.In Tees, Angles, Flats And Channels , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of Approved Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Providing & Fixing In Position Galvalume/Zincalume Flashings, Cappings, Ridges, Gutters Upto 600Mm/610Mm Girth And Min 3.00M In Length (Cold Rolled Steel 550 Mpa Yeild Stress Astm A 446 Grade E) With Hot-Dip Metallic Coating Of Aluminium-Zinc Alloy(Az 150 Galvalume) (150 Gms/Sqm Total Of Both Sides With Al-Zn Composition= 55% & 43.5% Resp. & 1.5% Si Conforming To Astm 792/ As 1397) 0.45 Mm Base Metal Thickness And 0.50Mm Total Coated Thickness, Factory Cut At All Heights For Roof, Side & Gable Cladding Complete In All Respects With Az 150 Gsm Smp Color Coated (20Mic Exterior Coat Of Silicon Modified Polyester Paint System Over 5 Mic Primer And 5 Mic Polyester Back Coat Over 5 Mic Primer) Incl. Fixing To Purlins With No 12X14X55Mm Mechanically Galvanised Hex Head Self Drilling Screws Of The Best Quality As Per As-3566 Class 3-4 Approved, Which Should Be Compatible To Be Used With Sheets. With Integral Washers And Epdm Seals Etc. Silicon Sealant Non-Hardening Neutral Cure Type Shall Be Applied At All End Laps, Complete As Directed. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. Plain Grill , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excludingfixingaccessoriessuchasnuts,Bolts, Fasteners Etc.). , Providing And And Laying Antiskid Floor Tiles 12 X 12 Upto 16 X 16 In Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is:15622 Of Approved Make In Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. Light Shades , Providing And Fixing 1St Quality Ceramic Glazed Wall Tiles (Johnson, Somany, Kajaria )Conforming To Is:15622 (Thickness To Be Specified By The Manufacture Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @3.3Kg Per Sq.M Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. Wall Ceramic Glazed Tiles : 300 X 600 , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Jet Black , Providing & Fixing 18 Mm Thk Flame Finish Granite Tread Tiles In Single Piece In Jet Black With Rounded Off Nosing, Antiskid Groove Laid On 20 Mm (Average) Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Neat Cement Slurry Including Pointing With Pigmented Cement Slurry To Match The Shade Of Slab, Cleaning Etc. Complete. ( Price Range 2000 To 2100 Rs Per Sq Mtr.) , Providing And Fixing Granite Stone Slabs (Mirror Polished) 18Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On Cement Paste And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. Jet Black , Providing And Laying Polished Granite Stone Flooring, Coping In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building, All Complete As Per The Architectural Drawings, With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade, Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Polished Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. ( Price Range 1550 To 1600 Rs Per Sq Mtr.) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm .80 Mm Thick In All Colours Except Grey (M40 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm. 80 Mm Thick In Grey Colour (M40 Grade) , Providing And Fixing 18Mm Thick Polished Black Granite Machine Cut For Kitchen Platforms, Counters, Window Sills, Door Frame, Urinal Partitions , Fascia And Similar Locations Of Required Size Of Approved Shade, Colour And Texture Laid Over 20Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) With Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing,Moulding And Polishing To Edge To Give High Gloss Finish, Etc. Complete At All Levels.( Price Range Rs.1500 To Rs.1700 Per. Sq.M ) , Providing 25Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 60 Cm L X45 Cm H X 15 Cm T , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand). 20 Mm Thick. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 (1 Cement: 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Waterproofing Treatment To Sanitary Blocks Consisting Of Layers Of Laterite Stone Coba Of 75 Mm Thick In Cement Mortar 1:2 Sand Witched Between Two Layers Of Cement Mortar 1:4 (20 Mm Thick ) Mixed With Water Proofing Compound, Top Finishing Coat Of Cement Slurry 6 To 12 Mm Thick With Water Proofing Compound Etc. Complete With 32 Mm Dia Pvc Pressure Relief Pipe Of Adequate Length Including Waterproofing Treatment To 750 Mm Height (Maximum) Of Side Wall, And Bottom Surface In Cement Mortar 1:4 With Waterproofing Compound And Covering 10 Years Guarantee On Court Fee Stamp Of Rs. 100 With Ponding Test Including All Lead, Lift Etc. Complete As Directed By Engineer. , 12 Mm Thick Cement Plaster 1:4 (1 Cement:4 Fine Sand) , 6Mm Thick Cement Plaster To Ceiling With 1:3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer , Extra For Plastering Done On Moldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level. In One Coat , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. (A)12Mm Cement Plaster 1: 3 (1 Cement : 3 Sand) , Forming & Finishing The 20 Mm Groove In Plastered Surface & Repair The Edges As Per Specifications And Directions Of The Engineer In Charge. , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws , Plugs And Priming Coat On Unexposed Surfaces Etc. 50X12Mm Size. , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 300X 16 X 5 Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Provided And Fixing 150 Mm Chromium Plated Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutters Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete. 200 X 10 Mm , Providing Frp Door Shutters 35Mm Thick With Frame Size In Clear Opening Of 0.75X2.10M Hinges And Screws Complete., , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And Fixing Of Aluminium Window With 3 Tracks And 2 Shutters Sliding Window With Tobular Frame Ployster Powder If Thicness 75-80 Microns With Approved Standard Accessaries Such As Ball Beaing Rollers, Concealed Lock, 6Mm Thick Plain Clear Glass With Epdm Beading Etc. , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete. 10 Mm Dia , Drilling 150 Mm Deep Hole In R C C And Grouting The Rebar With Lockfix Etc Complete.12 Mm Dia , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead Extra For Dismantling Trusses, Rafters, Purlins Etc. Of Steel Work, For Every Additional Span Of One Meter Or Part Thereof Beyond 10 Mts. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Doors, Windows And Clearestory Windows (Steel Or Wood) Shutters Including Chowkhats Architrave Holdfast Etc. Complete And Staking Within 50 Mt. Lead. Of Area 3 Sq.M. And Below , Dismantling Wood Work Of Area Below 40 Sq.Cm. Wrought Framed And Fixed In Frames, Other Frames And Trusses Including Stacking Of Material Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Main Entrance Gate In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Mahadev Big Mural In Frp As Per Tender Drawing , Providing & Fixing Below Mentioned Items Made In Fiber (Frp/Grp/ Any Other Material Specified By Vendor) Alongwith Fabricating A Rigid Skeletal Frame Work By Welding Steel Bars/Weld Mesh As Per The Desired Size, Shape And Profile Of The Finished Structure .Finish Should Be Simillar To The Photofeatures Approved By The Architect. Rate Should Be Inclusive Of Scaffolding , Reinforcement Welding, Framework As Per Structural Design. Work Should Be As Per Detail Design & Drawing And Satisfactory Of The Architects. Theming Work For Nandi In Frp As Per Tender Drawing , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Laying 300X350X160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete) , Supplying And Stacking Of Good Earth ( Garden Soil) At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth (Garden Soil) In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , Supply At Site Of Work/Store Deoiled Neem Cake Duly Packed In Used Gunny Bags As Per Mort & H Specification 308.2 , Supplying Of Sludge Duly Stacked At Site/Store As Per Mort & H Specification 308.2 , Filling Mixture Of Earth & Sludge Or Manure In The Desired Proportion In Trenches Flooding With Water And Leveling (Cost Of Supplying Earth And Sludge Or Manure And Mixing Excluded). , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Rubra , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Saraca Ashoka , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neem , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Nyctanthes , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Peltophorum Pterocarpum , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Bauhinia Purpurea , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Filliciam Decipiens , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cordia Dichotoma , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Cassia Fistula , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Millingtonia Hortensis , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Jacaranda Mimosifolia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Neolamarckia Cadamba , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Thevetia , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Michelia Champaca , Providing, Laying And Planting Various Trees & Palms As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. Plumeria Alba , Supplying & Planting Shrubs, Creepers, Ground Covers, As Listed Below As Per The Mentioned Size Including Adding Fertilizers As Per Planting Schedule, Manure And Neem Cake Etc. Including Their Maintainance Upto 3 Months During Which The Contractor Is Suppose To Maintain All These In All Respects Such As Watering, Pruning, Spraying Of Pesticides, Fungicides, Insecticides, Adding Fertilisers, Removing Of Weeds As Per Specification And Direction Of The Engineer And Also Replacing With Similar Plants In Case Of Death Of Any Plants. The Plant Will Be Selected And Approved By The Engineer Before Plantation. , Providing And Fixing White Vitreous China Type Water Closet Squatting Pan (European Type W.C. Pan) With Dual Flushing (Citren Nelson/ Similar)With Stop Cock Wall Flanges Flush Pipe Or Elbow And Vacuum Breaker Coupling Etc. Including Cutting Making Good The Walls And Floors Where Required. (Excluding Handicap Toilets) , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainless Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. (All Ewc Including Handicap Toilets) , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flange Jaquar Make Or Equivalent. Confirming To Is 8931;1993 For Orissa Pan. 15Mm Nominal Bore , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430 X 260 X 350 Mm And 340 X 430 X 265 Mm Sizes Respectively With Pvc Automatic Flushing Cistern With Fittings, R.S. Or C.I. Brackets, Standard Size Galvanized Steel Flush Pipe And Spreaders With Brass Unions & G.I. Clamps Complete, Including Painting Of Cistern And Fittings, Cutting And Making Good The Walls And Floors Where Required. (A)One Urinal Basin With 5 Liters P .V .C. Automatic Flushing Cistern. , Providing And Fixing Vitreous China Wash Basin With Rs Or C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Including Cutting And Making Good The Walls Where Required. Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing Liquid Soap Container With C. P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws. Plastic Container , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 110Mm , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door : 75Mm , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Wall Mixer With 3 In 1 System With 115Mm Long Bend Pipe For Connection To Over Head Shower Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing & Fixing C.P. Brass Towel Rail Complete With C.P. Brass Brackets Fixed To Wooden Cleats With C. P. Brass Screws. 750X20 , Providing & Fixing Soap Dish Chromium Plated With Brackets Fixed To Wooden Cleats With Cp Brass Screw , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed .110Mm Dia , Providing And Fixing Rigid Pvc S.W. R. (Soil, Waste And Rain Water Drainage Pipes Of Approved Make Including Lubricant Etc. Complete (Single/Double) Socket-Ed. 75Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating.110Mm , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating. 75Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door :110Mm , Providing And Fixing Rigid Pvc Bend (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete Bend With Door : 75 Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door :110Mm , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, With Door : 75Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door 110Mm , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door . 75Mm , Providing And Fixing R.P.V.C. Vent Cowl: 110Mm , Providing And Fixing R.P.V.C. Vent Cowl: 75Mm , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Cm2 In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar. , Providing And Fixing Square Mouth S.W. Gully Trap Grade A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of The Cover To Be Not Less Than 4.53 Kg.) And Frame To Be Not Less Than 2.72 Kg As Per Standard Design:.B) 150 X 100 Mm Size P Or S Type , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 25Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching ,Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. 32Mm Outer Dia. , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 15Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality : (Toilet Internal Ball Valve, 40 Mm Nominal Bore . , Providing And Fixing Non-Return Valve Of Approved Quality :40 Mm Nominal Bore , Providing And Fixing Ball Valve ( Brass ) Of Approved Quality .25 Mm Nominal Bore , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 15 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 20 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 25 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 32 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 40 Mm , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5. 50 Mm , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701;1996. 1000 Lit. Capacity , Electrical Works , Supply ,Installation,Testing & Commisioning Of 3 M High Galvanised Decorative Conical Step Pole With Decorative Light Single Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6 To 1M. In Length Along With Pole Cap Of 300Mm / Suitable Length And 80 Mm /Suitable Dia.(Suitable To Pole Top) Duly Welded With Provided Leads, And With Foundation Bolts Having Bottom Dia. From 105 To 141 Mm, Top Dia. From 65 To 77 Mm Complete With All Required Accessories Like Junction Box With 15A Input Output Connectors , 0.5 - 6 A C Curve Sp Mcb For Suitable For Each Light Fittings 3 Core 2.5 Sq. Mm Cu Flex. Cable For Light Fitting From Junction Box To Light Fittings And Its Termination Of Cables Should Be Made Using With Proper Lugs ,Pole Will Be Painted With P U Paint As Per Gtdc Color Choice .Etc.Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 40W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 40W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:40W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 4800Lm, Cri(Ra):80, Led Colour Temperature: 3000 To 5700K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of Architectural Pole Of 6Mtr Height Single Arm Made Of Galvanised Iron Sections Of 140Mm & 76Mm Dia. Wind Speed Considered In Design 50M/S, Is 875: Part - 3 :1987 .Material For Tubes Steel Of Grade Yst 210. Material For Base Plate Steel Of Grade E250 To Is 2062 ; 2011. The Bracket Will Be Provided With Reducer/Expander For Holding The Suspended Type Fixture On To The Main Pole With All Arrangements Having Position Perpendicular To The Ground. The Bracket Shall Be Single Arm On 6Mtr With A Span Of 1000Mm. The Bracket Top Shall Be Covered With Frp Cap To Enclose The Pipe. The Pole Will Be Placed With A Aluminium Embellishments On The Bottom & Middle Section For Aesthetic & Decorative Purpose. The Pole Will Be Provided With An Inbuilt Ip 65/66 Junction Box To Fix 32Amp Connectors & 6Amp Mcb Inside The Cut Window Of The Bottom Pipe The In Built Box Should Have A Flush Door Of Suitable Size. The Decorative Pole Will Be Mounted On A Square Base Plate Of Size 250 X 250Mm Having 12Mm Thickness. The Mounting Steel Plate Along With Hot Dip Galvanised Foundation Bolts Of Size M16 X 600Mm To Be Used For Ensuring Firm Grouting In The Specially Designed /Provided Reinforced Cement Concrete Foundation. The Galvanised Pole Should Be Painted In 3 Layer Coating (Coating Thickness Should Be More Than 50 Microns Minimum) In Which 1St Layer With Etch Primer, 2Nd Layer With Epoxy Zinc Primer & 3Rd Final Layer With Pu Paint Of Matt Black On Pole And Golden On Aluminium Embellishment Or As Per Gtdc .Make-Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supply,Installation,Testing,Commisioning Of 70W Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management (Pdchm) And The Ip65 Optical Compartment With High Power Led/S Is Comprised Of A Deep Drawn Chemically Polished And Co-Extruded, Thermoformed Polycarbonate Protector Stabilized Agent Uv Rays Suitable For 70W Led. Fitting Should Be Suspended Mounting Type Fixture. System Wattage:70W Led, Protection Class:Ip65, Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency: 50-60Hz, Operating Voltage:120- 277Vac, Operating Temperature: 0Deg To +50Deg C, Single Phase Ac Supply. Led Lumens: @120Lm/W 8400Lm, Cri(Ra):80, Led Colour Temperature: 3000K, Life Span:59,000 Hours,, Physical Body: Die Cast Aluminium Base, Body Spun Aluminium, Diffuser: Convex Type Translucent / V Translucent Polycarbonate Glass, Mounting: Suitable For 48Mm Od Pipe, Finish: Powder Coated Black, Driver Power Factor:0.95, Thd:7.8%,Surge Protection: 4Kv, Efficiency:87%. Fitting Should Have Inbuilt Driver With Efficiency 0.9 And Having Surge Protection Device Of 4Kv And External Surge Protection Device Of 10Kv. Ip65 And Lm79-2019 Report To Be Provided. Make: Havells, Reytek, Suncity, La Luminie As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Of Concealed Type Step Light With 6W Led Lamp Die-Cast Aluminium Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs. At L70B50, Including Driver By Making Necessary Arrangement/Recess In Wall To Make It Flush With Surface ,Ip Rating : Ip 67 ,Ik10 Rated , Connecting Wire, Including Gear Box And Junction Box For Cable Connection Complete And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supply ,Installation Of Tree Uplighter With Spike,9W Led Lamp Complete With Ip66, 24Vdc, Suitable Watts Driver / Power Supply (If Any), Connecting Wire,.Complete With All Accessories And Coated With Epoxy Zinc Phosphate Primer And Finished Using Environmentally Stable Polyurethane Based Paint .Make:- Havells,Reytek,Philips,Crompton,Leksa, La Luminaire, Wipro, Atilite, Nice. As Required As Directed By The Engineer In-Charge. , Supplying And Erecting Wall Mounted Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Complete. , Supplying And Erecting Bulk Head Led Fitting Max. 10-12W With High Transitivity Diffuser With System Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd0.95, Operating Range Of 140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50, Ip66, Ik09 Rated Including Driver Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With Accessories Complete. , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 2.5 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 3 Core 16 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 16 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. (A) In Soily Strata , Laying Of One Number Additional Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. A) In Soily Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Construction Of Manhole Rectangular In Shape Including Cement Concrete 1:3:6 (1 Cement:3 Coarse Sand:6 Graded Stone Aggregate 20Mm Nominal Size) Foundation Thickness Of Concrete 20Cms And Offset 10Cms On Both Sides And First Class Brick Work With Bricks Class Designation 100Kg/Sq.Cm (Wire Cut Bricks) Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 23Cms Thick Including Providing & Fixing Ci Footrests Confirming To Is 5445/69 Or Revised And Whose Weight Shall Not Be Less Than 5.30Kgs Including Fixing In Man-Hole At 30Cm C / C In 20X 20X10Cm Cement Concrete Block 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size) And 12Mm Thick Plaster Inside And Outside With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Adding Waterproofing Compound Of Approved Brand In Cement Mortar With A Floating Coat Of Neat Cement And Making Channel In Cement Concrete 1:2:4 (1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20M Nominal Size) Neatly Finished Complete As Per Standard Design. Iii) Inside Size 0.60X0.60M And 0.60M Deep (With Medium Duty Di Manhole Cover & Frame Of Size 0.60X 0.60M Weighing 90Kgs ) Including Fixing With Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size And Applying The Frame & Cover With Coal Tar.(Refer Quantity In Drawings) , Providing At Store Or Site Work Non-Pressure Reinforced Cement Concrete Pipes Of With Collar Joints Conforming To Is:458-2003 Revised As Per Amendment No.11 , Including Freight, Carting, Loading, Unloading, Stacking Etc. Complete. C) 150 Mm Dia.Np2 Class , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 1.5/2.5 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 4 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 X 16 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 X 16 Sq. Mm. , Supply Installation, Testing And Commissioning Of Following All Outdoor Feeder Pillar-1/Panels Comprising Below Points. 1)-Panels Shall Be Fabricated Out Of 16/14 Swg Crca Sheet Steel, With Necessory Structural Supports In Form Of Structural Steel Sections. 2)-Floor Mounted (Include Stand), Ip-55 Degree Protection, Bottom Or Top Bus Duct Or Cable Entry As Per The Case & Bottom Cable Exit Steel, 2Mm Frame, 1.6 Mm Compartments & Tank Process Treated & 2- Times Epoxy Painted. 3)-Proper Gland Size Holes To Be Provided By The Manufacturer With Proper Sticker And Danger Sign On All Sides Of Panel. 4)-Current Density- 1.2 Ampere/1 Sq.Mm (Is-8623 For Factory Built Assembly). 5)- Earthing Terminal At Both End. 6)-Paint-- Exterior Enclosure Tank Process Treated & 1 Coat Of Epoxy Painted And 2 Coat Of Siemens Grey As Per Shade Ral7032 With Pu Paint For Exterior And Black For Base Frame , Everywhere Maintaining Micron Upto 75. 7)All Starters Are According To Type-Ii Cordination .8)Any Other Related Details As Per Engineer Incharge. Refer Single Line Diagram. Note : Excluding Stabiliser & Energy Meter Cost.Main Incomer - 25 To 100 A Tpn Mccb,Thermal Magnetic ,25Ka -2 Nos.4 Pole Power Contactor 16A To 25 A ,415V -2 Nos.Programmable Digital Almanac Astro Timer Switch With 10 Hrs Battery Backup -2 Nos. Outgoing - 6 A To 32 A, C Series Sp Mcb , 10 Ka-15 Nos. 6 A To 32 A, C Series Tp Mcb , 10 Ka -6 Nos.And Miscellaneous Items, Wire,Selector Switch , Cable Terminal Blocks Etc. Space Provision Only For 3 Phase Meter(300 X 400 ,Lxh) And 3 Phase Stabiliser . , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only. (B) 10 To 40 A , Supply, Installation, Testing And Commissioning Of 3 Kva 1 Nos. Voltage Stabilizer ,Input Voltage Range (V ) =90-300 V ,Output Voltage (V ) =240 V ,Output Voltage Regulation = 1% Of Nominal Output Voltage,Automatics High & Low Voltage Cut Off Input And Out Put Voltage Circuit Protections, Single Phasing Preventer/Phase Reversal Protection,Over Load & Short Circuit Protection(Use Mcb),Independent Phase Control,Lcd /Led Display For Regulations Mode ,Bypass Mode & Fault Conditions,Automatic Bypass: A Fault Conditions,Protection Class : Ip 20 ,Ambient Temperature : 0 To 45 Degree Celsius ,Wave Form Distortion: Pure Sine Wave. , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. A) Sp, Cat A , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (C) 6 Way (8+18), Double Door, Horizontal Type Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (E) Tpn, Cat A , Supplying And Fixing Following Rating Four Pole (Triple Pole And Neutral) 415 V Rccb Having A Sensitivity Current Upto 300Ma In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) 25 A, Cat A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required. , Supply , Installation , Testing And Commissioning Of Cable Junction Boxes Ip 66/67 Weather Proof(Size -155 X 210 X 92 (Lxbxh)Mm + Cable Termination Upto 16 Sqmm Size.), For Outdoor Installation(With Knockouts For Cable Entry) With All Accessories. Make: Hensel ,Neptune As Required As Directed By The Engineer In-Charge , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark, Of Approved Brands Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size Not Less Than 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe . G)Watering Arrangement(Plumbing Will Be Paid Seperately). (B) In Rocky Strata , Earthing With Gi Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking/Lifting Arrangement And Watering Pipe Etc. (But Without Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) And Disposal Of Excavated Soil. C)Watering Gi Pipe, 20Mm, Class B, With Funnel As Per Specs. D) Charcoal/Salt As Per Specs ( Paid Seperately). E) Refilling The Pit Of Size 1.0X1.0X 3.0 Mtrs(Min) With Soft Black Agriculture Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe.G)Watering Arrangement(Plumbing Will Be Paid Seperately). B)In Rocky Strata , Extra For Using Salt And Charcoal For Pipe Earth Electrode As Required( 65 Kgs Of Charcoal And 5 Kgs Of Salt). , Extra For Using Salt And Charcoal For Gi Or Copper Plate Earth Electrode As Required( 96 Kgs Of Charcoal And 5 Kgs Of Salt) , Supplying And Laying 25 Mm X 6 Mm Gi Strip At 0.5 M Below Ground As Strip Earth Electrode Including Soldering Etc. As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 6 Swg Gi Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. A) Group B -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required. (C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. B) 25 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (C) 32 Mm(Ground To Db) , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required D) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required A) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required B) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required (C) 6 Module (200Mm X 75 Mm) Cat A , Supplying & Erecting Of Led 9 To 10W Tube Light Fitting (2 Feet) With Pc Housing, Heat Sink, Integrated Hf Electronic Driver Complete. Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supplying And Erecting Outdoor Square / Circular Max. 20 W Pendent Light With Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd10%, P.F. 0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70B50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Suspended Accessories Complete. , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supply And Erecting Fan Hook Box ( 100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Gi Pipe Medium Class 25 Mm (Civil Gsr 1034 (F)(Iii))
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
44.
Health and Family Welfare #11073758 Technical Bid
Tender For Major Works At Girls Ashram Hostel Merpur Kotda Udaipur- 1 Dismantling Doors, Windows And Clearatory Windws Steel Or Wood Shutter Including Chowkhats And Holdfasts Etc. 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead: For Thickness Of Tiles 10Mm To 25Mm. 3 Dismantling Gi Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes And Including Stacking Of Pipes Within 50 Meter Lead: 4 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. 5 Grading Roof For Water Proofing Treatment With Water Proffing Compound. Cement Mortar 1:4 (1Cement : 4 Coarse Sand) 6 Providing & Laying Broken Glazed Titles On Roof ( Broken Glazed Tiles Not Less Than 9 Kg/Sqm) On Top Of Hot Bitumen @ 1.7 Kg/Sqm. (1.40 Kg Of Vg-40 (30/40 )Grade And 0.30 Kg/Sqm. Of Vg-10 (80/100) Grade) And Joints Filled With Cement Mortar 1 :2 (1 Cement:2 Marble Dust Mixed With Water Proofing Compund All Complete As Per Direction Of Engineer-In-Charge. 7 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) 8 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) 9 Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete.New Plastered Surface (Three Or More Coats) 10 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 11 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm 12 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete 13 Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Sqm Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3Mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge 14 Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). 15 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10Cm Long Embedded In Cement Concrete Blocks 15X10X10 Cm Of 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Require Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 16 Providing And Fixing M.S. Sheet 1Mm Thick Dabble Leaf Door Shutter In Angle Iron Frame 35X35X5Mm Suitabilly Diagonally Braced With 25X3Mm Flat Iron Above And Below Lock Rail Of Size 50X5Mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint Add Extra For Double Leaf Shutters. 17 Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3Mm With Suitable Screw At Not Exceeding 150Mm Distance. 18 Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. 19 Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged : Aldrop Of Mild Steel 12\ Long X12Mm Dia 20 Steel Hinges For Wooden Chowkhat 4\ Size. 21 Steel Handle 6\ Size 22 Labour Charges For Repair To Door / Window Without Using Any Material Such As Applying Randha (Finishing) Tightening Of Bolts & Screw Etc. 23 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 24 Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated „J‟ Or „L‟ Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified. 3.0Mm Thick (Wt. 5.0 Kg./Mtr. Sq.) 25 Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: 26 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 27 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 28 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture : 29 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 30 Providing And Laying Ceramic Mat Floor Tiles (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown Of Any Size, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 31 P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440Mm. 32 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) 15 Mm Nominal Size 33 20Mm Nominal Size 34 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings, This Included Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement , Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.(External Work).15 Mm Nominal Size 35 20Mm Nominal Size 36 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 75 Mm Dia 37 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 38 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia 39 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Coupler (Socket) 160 Mm Dia 40 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Plain Tee 160 Mm Dia 41 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Tee 110Mm Dia. 42 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 110Mm Dia. 43 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 160Mm Dia. 44 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 110Mm Dia. 45 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 160 Mm Dia. 46 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Bend (Top Side) 110Mm Dia. 47 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 110Mm Dia. 48 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 160Mm Dia. 49 P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design. 1000 Litres Capacity. 50 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 15Mm Nominal Bore. 51 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 25Mm Nominal Bore. 52 Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick C.C Bed Of 1:5:10, M-15 Grade C.C Floor & Rcc Slab Covering With M15 Grade C.C. Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140X150 Cm.(For 50 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect 53 Size 230 X110 X150 Cm.(For 20 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. 54 P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall :Size 550 Mm X 400 Mm 55 P & F Looking Mirrors With P.V.C. Frame Of Approved Make As Per Direction Of Engineer-In-Charge Size 500X400Mm 56 P & F Grating Of Approved Quality/Make:Stainless Steel Sheet Size 125Mm Dia. 57 P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: Brass 400 Gm,15Mm Nominal Bore. 58 Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade C.C. Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead.Depth Up To 0.5 M 59 Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick C.C. 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.-Do- Size 450 X 450Mm Depth Upto 0.5 M Cement Cover With Frame 60 Construction Of Soakage Well In All Type Of Soil With 300 Mm Thick Dry Masonry, Top And Bottom 300 Mm Course In Cm 1:6, 80Mm Thick Stone Slab, Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.C Flooring , Earthwork Complete As Per Approved Drawing Including Disposal Of Earth Within A Lead Of 50 Mtr.: Size 300 Cm. Dia Outside & 300 Cm. Depth . 61 P & F Flush Cock / Flush Valve (Is : 9758 Mark) For Wc Of Approved Quality Make : (-Do-) Half-Turn Exposed 25Mm Nominal Bore. 62 P& F Waste Coulping With Fittings Of Approved Quality /Make: C.P Brass 32 Mm Dia 63 P& F Waste Pipe With All Fitting G.I(B Class) 32Mm 64 Construction Of Open Drain With 112Mm Thick Brick Masonry In Cm 1:4 Semi Circular S.W. Glazed Channel (Confirming To Is Standards) Fixed With Cement Mortar 1:1 Over A Bed Of 100Mm Thick C.C. 1:5:10, Filling Of Edged With M-15 Grade C.C. Flooring, 12Mm Cement Plaster 1:4, Over All Exposed Faces, Excavation & Disposal Of Earth With In A Lead Of 50 Mtr Complete As Per Approved Drawings : 150 Mm Drain,225Mm Av. Depth Width 15 Cm S.W. Glazed Channel. 65 Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 150Mm 66 Supply Of Erw M.S. Black Casing Pipe Isi Marked (Is:4270/1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 150 Mm Nominal Bore Of Pipe 67 S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size: 150Mm Dia 68 S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. 69 Providing & Fixing Of Hdpe Pipe Confirming To Is:4984:2021 For Water Supply Suitable For Submersible & Jet Pump With Required Fittings Ie Socket, Elbows, Tee Etc. Complete In All Respect. For Vertical Installation 63 Mm Od 6 Kg / Cm2 70 For Horizontal Installation 63 Mm Od 4 Kg/ Cm2 71 Sitc Of Radial / Mixed Flow Water And Anti-Corrosive Liquid Filled Submersible Motor Pump Sets Suitable For 100/150Mm Dia Borewell. The Size Of Adopter Fixed On Top Of The Motor Should Exceed The Top Of Coupler , For Safegaurd The Coupler. The Job Includes Labour Part Of Lowering Of Riser Pipe G.I./ H.D.P.E. With Rope, Cables & Pump, Installation Of Complete Fitting And Accessories, Jointing Of Electrical Cables Up To Starter. All Labour For Testing Of Submersible Pumps Set And Supply Of Water To Water Mains, Complete In All Respect. 100 Mm Diameter Submersible Pump Shall Have Following Hp Rating, Phase, Head Range, Discharge Range Respectively. 3.0 Hp, 1-Ø, (40 -170)Mtr, (60- 20) Lpm Copper Wound 72 Sitc Of Ip 54 Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Coordination Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection(For Three Phase Pumps), Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps, 2P/4P Mcb Etc. Suitable For Following Rating Motors Complete In All Respect. For Three Phase Submersible / Mono Block Pump 3.0 Hp To 5.0 Hp ( Dol Starter ) 73 Providing & Laying Of Polypropylene Rope Confirming To Is:5175 For Submersible Pump Of Following Sizes. Complete In All Respect. 20Mm (Suitable For 90 Mm Od Pipe) 74 Supply And Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. 10.0 Sq.Mm 3 Core Flat / Round 75 Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Short Point (Up To 3 Mtr.) 76 Medium Point (Up To 6 Mtr.) 77 Long Point (Up To 10 Mtr..) 78 Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr On Board 79 Medium Point (Up To 6 Mtr.) 80 Long Point (Up To 10 Mtr..) 81 Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 82 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Blanking Plate 83 Modular Mcb 6 A To 32 A Dp (Is:8832 Marked) 84 Providing & Fixing Of Modular Type 100W Step Fan Regulator Duly Isi Marked (Is 11037) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Virgin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including Making Connections, Testing Etc As Required. 5 Step Fan Regulator 2 Module 85 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 1 X 1.5 Sq.Mm 86 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 87 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm 88 2 X 6.0 Sq. Mm. + 1 X 2.5 Sq. Mm 89 4 X 10.0 Sq.Mm 90 4 X 6.0 Sq.Mm 91 1 X 16.0 Sq.Mm 92 1X 4.0 Sq.Mm. 93 Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Glazed Door (Three Phase) Ik-09 And Ip-43 With Metal End Box 6 Way 94 Glazed Door (Single Phase) Ik-09 And Ip-43 With Metal End Box 12 Way (12+2) 95 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating 96 Double Pole Mcb(With B/C Curve Tripping Characteristics) 40 A Rating 97 Four Pole Mcb(With B/C Curve Tripping Characteristics) 50/63 A Rating 98 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners Etc. As Required. 32 Mm X 12 Mm 99 Making Of Hole In Wall (Brick/Stone) Of Required And Placing Np-2 Rcc Pipe Ring Of Required Size For Housing Exhaust Fan And Making Good The Same, With Cement Plaster Required Of Following Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Up To 457 Mm Size 100 P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 101 Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wound Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 300 Mm Sweep(900/1400 Rpm) 102 P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Required. Up To 380 Mm Size 103 Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminium Housing With In Built Driver , System Lumen Efficacy ≥ 110 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1170Mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm 104 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Surface Mounting (With Extruded Alumn. Housing ) Minimum Lumen Output 1600 Lm 105 Minimum Lumen Output 1950 Lm 106 Sitc Of Ip20, 1X1 Led Surface/ Recessed Mounting Backlit & Smd Mid Power Type Led Light Fixture Not Less Than 35 Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution.Operating Voltage Range 140-285 V, Hv Cutoff - Lv Cutoff Should Be 300-100V High Efficiency With 4 Kv Internal Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. Surface Moutning Minimum Lumen Output 3600 Lm 107 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 108 Providing & Fixing Of Extra Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Including Cutting, Threading, Drilling, Fixing Quarter Pin Etc As Required. 109 Providing & Fixing Of 450 Mm Sweep Oscillating Type Wall Mounting / Pedestal Type Fans With Three Speed, On And Off Position, Sintered Iron Bush Oil Impregnated, With Metal Front And Back 120 Or More Ribs Guard; Three No. Aluminium Blades, Minimum Air Delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./Min/Watt, Noise Level Should Be 110 Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core 1.5 Sq.Mm Copper Conductor ,Making Connections, Testing Etc. As Required. 300 Mm Sweep 111 Supply And Installation Of High Tensile Low Carbon Steel Rod Molecularly Bonded With 99.9 % Copper Thickness (250 Microns) And Confirming To Ul 467, Is/Iec 62561-2 Of Following Size And Length And As Per Point Mentioned (A), (B), [C), (D), (E) Below :- (A) Bore A Hole Of Dia. 100 Mm Of Required Length, Place The Rod In The Centre Of Hole (B) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri/ Erda Tested With Rms Capacity Of Minimum 30 Ka For Withstanding 1 Second .To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043-1987,Ieee 80-2013 (Clause 14.5D) , Ieee 837 & Ier 1956 With Latest Amendemnts © Connect The Rod With Copper Strip/Conductor/Wire With Suitable Clamp Made From Tinned Copper And Ss 304 Bolt (D) Place Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. (D) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. (E) Test Certificates For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 17.2 Mm Thick And 3 Mtr. Long 112 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. 8 Swg Copper Wire 113 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led/ Integrated Lens Diffuser & Should Be High Power Led Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Integrated Metal Case Potted Driver & Has A Unique Bis R Number ( As Per Is 15885) With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac & Low Voltage Cutoff @>=90 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs As Required. Led Street Light Fixture With Minimum Lumen Output 2500 Lm 114 Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. 32 Mm Dia. 115 Supply & Fixing Of Dry Powder Agent (As Per Is 4308:2019), Abc Type Fire Extinguisher (Stored Pressure Type) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test (For Cylinder Body) Certificate From Oem / External Nabl Accrediated Lab Is To Be Submitted. 6 Kg 116 Sitc Of Ro Water System With Filteration Stages = Particilate Filter- Membrane Life Enhancer Filter- Sediment Filter- Pre Carbon Filter- Ro Membrane Filter- Post Carbon Filter. Input Power Rating -230V Ac, 50Hz, Percentage Of Rejection Tds-90% Or Better, Having Following Features (A) Double Purification By Ro With Ess Or Latest Technology With Tds Indicator. (B) Spin Welded Ro Membrane Housing To Prevent Tempering. (C) Push Fit Component For Leak Proof Performance. (D) Fully Automatic Operation With Auto Start And Auto Off. (E) Ss/Abs Construction For Corrosion Free Lifespan. (F) Equally Suitable For Water From All Borewells, Overhead Storage Tanks, Water Tankers And Even Municipal Taps. (G) Ro Membrane Flushing - Auto Flush@ Every Start, Every Stop And Every One Hour Of Working For One Minute, Complete In All Respect With Following Capacity. Purification Capacity - 50Lph, Duty Cycle 270-500 Liters/Day 117 Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs 118 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 119 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 120 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size). 121 Kerb Stones Of 1200X300X150, 1000X450X150, 1000X600X150, 600X300X150 Size (M-30) Providing And Laying Cement Concrete Kerb Stones Of Different Sizes In M-30 Grade (Manufactured With Fully Mechanised Dry Cast Process With Forced Action Mixer Whose Arms Revolve Along The Main Axis And Rotate About Its Own Axis Also, Having Humidity Sensor For Moisture Control Of W/C Ratio In Concrete Mix. Manufactured With Steel Moulds (Milled And Manufactured In Csi Diamond Or Csi Nitro Process For Accuracy) On Steel Base Plate Of Min 16 Mm Thick; Having Vibration And Pressing Action Both Together With The Help Of Multiple Synchronised Vibrators. Power Of Hydraulic Station Should Be Minimum 50Kw For Compaction And Cured In Controlled Chambers Having Humidity Control And Automated Air Circulation System) In Position To The Required Line, Level And Curvature Jointed With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Making Of Joints, Drainage Opening Wherever Required. 122 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 123 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 124 Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 125 Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix 126 Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix 127 Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. 128 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. 129 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) 130 Random Rubble Stone Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Five Level Above 30Cm. Thick Walls In : Cement Mortar 1:6 ( 1-Cement : 6-Sand). 131 Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 25 Mm Thick. 132 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 133 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 134 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 135 Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size).
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
45.
Power #11055304 Price Bid
Tender For Estimate For 11 Kv Line Interconn. Work From Bagsi To Bagsi Dom, Jajankhedi And Manikhedi Agr Feeder Under Nazirabad D/C Of (Oandm) Dn. Bhopal - 140 Kg.,8.0 Mtrs. long PCC pole 2 H-Beams 152 X 152 mm., 37.1 Kg./Mtr.-11 mtr. Long = 408.1 kg 3 AAAC Raccoon conductor 0.075 sq. inch (80 sq.mm. Al.Eq.) 4 M S Channel 100X50x6 mm 5 M S Angle 65X65X6 mm 6 33 KV Pin Insulator Polymer Composite (10 KN) 7 11 KV Pin Insulator Polymer Composit (5 KN) 8 33 KV (45KN) Composite Polymer Disc Insulators 9 33 KV Strain hardware (T&C type) fittings 10 11 KV(45KN) Composite Polymer Disc Insulators 11 11 KV Strain hardware (T&C type) fittings 12 11 KV.C.Ts.(Outdoor dry type) 300-150/5-5 Amps 13 11 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel 14 11 KV control & relay panel with numerical static relay for double feeder protection 15 3Ph 4W 3x63.5V lb=5A Imax=10A, HT trivector meter,0.5s,(For Consumer metering) 16 D.C. Channel (3.8 mtrs) 100x50x6mm (SET) 17 Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 8 ft (2.4 mtr ) centre DP 18 M.S.Flat 50x6 mm 19 Red oxide paint 20 Aluminium paint 21 Stay Insulators 90X65mm 22 Back filling of poles with boulders. 23 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 24 M.S.Nuts with Bolts 25 Danger Boards Enamelled 11 KV 26 Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole 27 Jointing Sleeves suitable for Rabbit (55Sq.mm.Al. Eq. ) AAAC conductor 28 Aluminium Binding wire and tape 29 MS strain plate 65x8mm 250mm long 30 Stay Wire 7/3.15 mm.(7/10 SWG) 31 Stay set complete without Stay wire 16 mm. (Painted) 32 Stay set 20 mm. complete without Stay wire (Painted) 33 Erection of Plinth per VCB- 33KV or 11KV 34 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 35 Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay 36 Concreting of Rail / Hbeam supports @0.65 Cmt.per pole including muffing of pole 37 Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth 38 Concreting of structures & foundation (1:3:6) 39 G.I. STRIP 25X3 MM1 40 G.I.Pipe 40 mm Dia C grade type 41 Galvanized nut & bolt with washer 42 Bentonite compound powder 43 Stone Block/Pre cast block for base pedding(450X450X75MM) 44 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 45 Marshelling box with 10 no. connectors 46 Meter box with TTB 47 33 KV Polymer Lightening arrestor Gapless type 48 Additional Erection Charge 49 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 50 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal 51 GST on Transportation @5% 52 GST on (Contractor side Material + Labour) @18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Madhya Pradesh View Result →
46.
Power #11055303 Price Bid
Estimate For New 33 Kv Runaha Feeder 1.3 Km From 132 Kv S/S Runaha To 33/11 Kv Substation Runaha At Under Nazirabad D/C Of (Oandm) Dn. Bhopal - WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 2 (v) ACSR Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.), (6/4.72 + 7/1.57 mm) 3 33KV(104.98 SQMM )AL-59 ACS XLPE Covered Conductors as per EN:50397,P-1:2020, SS 4240813,SS 4240814,IEC 1232 WITH 95⁰C CONTINUOUS OPERATINGTEMPERATURE of ACS class 20S A /Grade A extruded seme conducting Material,with MVCC Accessories (1KM Cond.) 4 M S Channel 100X50x6 mm 5 M S ANGLE 75X75X6 mm 6 M S FLAT 65X8 mm 7 33 KV Pin Insulator Polymer Composite (10 KN) 8 33 KV (45KN) Composite Polymer Disc Insulators 9 33 KV Strain hardware (T&C type) fittings 10 D.C. Cross arms 5 ft centre to center (100x50x6 mm) Channel 11 Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 5 ft(1.5 mtr) centre DP 12 M.S.Flat 50x6 mm 13 MS strain plate 65x8mm 250mm long 14 Red oxide paint 15 Aluminium paint 16 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 17 M.S.Nuts with Bolts 18 Jointing Sleeves suitable for Dog (100Sq.mm.Al. Eq. ) AAAC conductor 19 Aluminium Binding wire and tape 20 Danger Boards Enamelled 33 KV 21 Stay Wire 7/3.15 mm.(7/10 SWG) 22 Stay set 20 mm. complete without Stay wire (Painted) 23 Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay 24 Concreting of structures & foundation (1:3:6) 25 Stone Block/Pre cast block for base pedding(450X450X75MM) 26 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 27 Additional Erection Charge 28 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 29 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal 30 GST on Transportation @5% 31 GST on (Contractor side Material + Labour) @18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Madhya Pradesh View Result →
47.
Power #11055295 Price Bid
Tender For Estimate For Providing Lilo Arrangement At 33/11 Kv S/S Parwaliya Sadak Under Parwaliya Sadak D/C - WPB160x160mm,30.44 Kg/Meter H beam,13 mtr long 2 IRON STEEL SCRAP 3 ACSR Panther conductor 0.20 sq. inch (200 sq.mm Al.Eq.) 4 (v) ACSR Dog conductor 0.10 sq. inch (100 sq.mm. Al.Eq.), (6/4.72 + 7/1.57 mm) 5 Copper Control Cable 2 Core. 2.5 Sq.mm. (Unarmoured) 6 Copper Control Cable 4 Core. 2.5 Sq.mm. (Unarmoured) 7 Copper Control Cable 8 Core. 2.5 Sq.mm. (Unarmoured) 8 33 KV CT Outdoor Oil immersed type, 3 Core, 200-100/5-5-1 Amp, Class 0.5 for differential protection 9 33 KV VCB, Outdoor Porcelain clad type with complete structure and accessories excluding CT & pannel 10 33 KV control & relay panel with numerical static relay for Feeder protection 11 33 KV, ISOLATOR 600 AMP.(Turn and twist type) 12 M S Channel 100X50x6 mm 13 33 KV Pin Insulator Polymer Composite (10 KN) 14 33 KV (45KN) Composite Polymer Disc Insulators 15 33 KV Strain hardware (T&C type) fittings 16 33 KV Polymer Lightening arrestor Gapless type 17 M.S.Flat 50x6 mm 18 Horizontal & Cross Bracing set of MS angle of 50X50X6 mm for 5 ft(1.5 mtr) centre DP 19 Red oxide paint 20 Aluminium paint 21 Earthing Coil of 115 Turns of 50 MM.Dia and 2.5 Mtr. Lead of 4.0 MM G.I Wire 22 M.S.Nuts with Bolts 23 MS strain plate 65x8mm 250mm long 24 Stay Wire 7/3.15 mm.(7/10 SWG) 25 Stay set 20 mm. complete without Stay wire (Painted) 26 Danger Boards Enamelled 33 KV 27 Concreting of foundation of VCB (1:3:6) @ 3.5 cmt per VCB plinth 28 Concreting of structures & foundation (1:3:6) 29 33 KV composite polymer Strain set with hard ware suitable for Panther Conductor 30 Marshelling box with 10 no. connectors 31 T -clamps for Panther 32 Stone Block/Pre cast block for base pedding(450X450X75MM) 33 G.I.Pipe 40 mm Dia C grade type 34 G.I. STRIP 25X3 MM1 35 Bentonite compound powder 36 Galvanized nut & bolt with washer 37 Anti climbing devices ( Barbed wire 2.24 mm dia, 14 SWG) 38 Erection of Plinth per VCB- 33KV or 11KV 39 Stringing of Each 33 KV Bus- upper and lower including drop jumpering, jointing with clamps, incoming DP/ ME to BUS 40 Additional Erection Charge 1 41 Labour Charges & all Fabrication Charges (STC Sub Division will provide the raw material like M.S. angle, M.S. Channel, M.S. flat, etc. to the contractor and the contractor will fabricate the itemslike V-cross arm, Top clamp, D.C. Channel, clamp, etc. as per site condition. Those fabrication charges are included in the Labour charges.) no extra amount will be paid. 42 Transportation Charges for All Equipments & Materialsfrom area store to site & Site to Area store Bhopal
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Madhya Pradesh View Result →
48.
Housing Urban and Rular Development #11053840 AOC
Tender For Annual Repair Special Repair /Mow Works In Various Rb/Nrb Under Section No.7, Jail Sub Division No.1, Bhopal- 1 Ar/Sr/Mow Works In Various Rb/Nrb Under Section No.7, Jail Sub Division No.1, Bhopal 1St Call P.A.C. 40.00 Lakh,As Per Building Sor Wef 01-01-2024 Schedule Attached Complition Period 180 Days Please Enable Macros To View Boq Information Ar/Sr/Mow Works In Various Rb/Nrb Under Section No.7, Jail Sub Division No.1, Bhopal Building Sor Wef 01.01.2024 Probable Amount Of Contract - Rs. 40.00 Lakh S.No Description Qty. Unit Rate Amount 2 2.1 All Kinds Of Soil. 100 Sqm 803.0 3 2.6 All Kinds Of Soil Cum. 147.0 4 2.7 2.7.1 Ordinary Rock Cum. 287.0 2.7.2 Hard Rock (Requiring Blasting) Cum. 519.0 2.7.3 Hard Rock (Blasting Prohibited) Cum. 828.0 5 2.25 2.25.1 All Kinds Of Soil. Cum 30.0 2.25.2 Ordinary Or Hard Rock. Cum 53.0 6 2.27 2.27.1 With Hard Muram Having Cbr >12 % At Under Floors Including Watering, Ramming And Compacting (Minimum Compaction 95% Of Mdd) In Layers Not Exceeding 20Cm In Thickness And Dressing Complete. (Note:- Maximum Thickness Of This Layer To Be Provided Shall Be 30Cm) Cum 393.0 2.27.2 Supplying And Filing In Plinth With Soil (Other Then Bc Soil ) Having Mdd Not Less Than 1.85 T/M3 Under Floors Including Watering, Ramming And Compacting (Minimum Compaction 95% Of Mdd) In Layers Not Exceeding 15Cm Depth And Dressing Complete. Cum 331.0 7 4.1 4.1.1 With 20Mm Nominal Size Graded Stone Aggregate. 4.1.1.1 M-25 – Grade Concrete Cum 6338.0 4.1.1.2 M-20 – Grade Concrete Cum 4933.0 4.1.1.3 M-15 – Grade Concrete Cum 4471.0 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 Sand : 6 Graded Stone Aggregate ) Cum 3890.0 4.1.2 With 40Mm Nominal Size Graded Stone Aggregate. 4.1.2.1 M-15 - Grade Concrete Cum 4403.0 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate) Cum 3808.0 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 Sand : 8 Graded Stone Aggregate Cum 3474.0 4.1.3 With Fly Ash. 4.1.3.1 1:2½:4:11 (1 Ordinary Portland Cement : 2½ Fly Ash : 4 Sand : 11 Graded Stone Aggregate 40 Mm Nominal Size) Cum 3459.0 4.1.3.2 1:2½:4:11 (1 Ordinary Portland Cement : 2½ Fly Ash : 4 Sand : 11 Graded Stone Aggregate 40 Mm Nominal Size) Cum 3150.0 Note: No Fly Ash Is To Be Added To Portland Pozzolona Cement In Any Case Which Itself Contains Fly Ash. 8 4.2 4.2.1 With 20Mm Nominal Size Graded Stone Aggregate 4.2.1.1 M-25 – Grade Concrete Cum 6582.0 4.2.1.2 M 20 – Grade Concrete Cum 5177.0 4.2.1.3 M 15 – Grade Concrete Cum 4714.0 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 4134.0 4.2.2 With 40Mm Nominal Size Graded Stone Aggregate 4.2.2.1 M-15 - Grade Concrete Cum 4647.0 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 4052.0 9 4.3 4.3.1 Upto Plinth: Foundations, Footings, Bases For Columns, Plinth Beams, Curtain Walls, Columns Below Plinth. Sqm 169.0 4.3.2 Above Plinth: Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Buttresses, And String Courses Fillets Etc. Sqm 267.0 4.3.3 Above Plinth: Columns, Pillars, Posts And Struts. Sqm 356.0 10 4.4 4.4.1 M-15 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 4471.0 4.4.2 M-10 (With 20Mm Nominal Size Graded Stone Aggregate) Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 3890.0 11 4.6 4.6.1 M-25 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 5095.0 4.6.2 M-20 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 5558.0 4.6.3 M-15 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 5095.0 4.6.4 M-10 (With 20Mm Nominal Size Graded Stone Aggregate) Nominal Mix -1 Cement: 3 Sand: 6 Graded Stone Aggregate. Cum 4515.0 12 4.7 4.7.1 M-15 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 7057. 00 4.7.2 M-10 (M 10) (With 20Mm Nominal Size Graded Stone Aggregate) Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 6477.0 13 4.15 Note For Item No. 4.15:- The Quantity Will Be Calculated By Multiplying The Depth Measured From The Sub-Soil Water Level Upto Centre Of Gravity Of Concrete Under Sub-Soil Water Level With Quantity Of Concrete In Cum Executed Under Sub-Soil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1M. 0.05M Or More Shall Be Taken As 0.1M And Less Than 0.05M Ignored. Cum 109.0 14 5.1.1 5.1.2 M-15 Grade Concrete Cum 5397.0 5.2 Reinforced Cement Concrete Work (With 20 Mm Nominal Size Graded Stone Aggregate) In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Posts And Struts Etc. Above Plinth Level And Upto Floor Two Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement: 15 5.2.1 5.3 Reinforced Cement Concrete Work (With 20 Mm Nominal Size Graded Stone Aggregate) In Beams, Suspended Floors, Roofs Having Slope Of Any Degree Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Staircases Above Plinth Level And Upto Floor Two Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement In Concrete Grade. 16 5.3.1 5.4 Providing And Laying Upto Floor Two Level Reinforced Cement Concrete (With20 Mm Nominal Size Graded Stone Aggregate) In Kerbs, Steps And The Like Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With Concrete Grade. 5.4.1 M-20 Grade Concrete Cum 5542.0 17 5.9 5.9.1 Foundations, Footings, Bases Of Columns, Etc. For Concrete Upto Plinth Level Sqm 190.6 5.9.2 Walls (Any Thickness) In Cluding Attached Pilasters Butter Esses, Plinth Beams And String Courses Etc. 5.9.2.1 Uptoplinthlevel. Sqm 219.0 5.9.2.2 Above Plinth Upto 3.6 M Height From Plinth Level Sqm 330.0 5.9.2.3 Extra For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De-Shuttering And Decentering At All Levels, Over A Height Of 3.6 M, For Every Additional Height Of 1 Metre Or Part Thereof. Sqm 40.0 5.9.3 Suspended Floors, Roofs, Landings, Balconies And Access Platform. Sqm 439.6 5.9.4 Shelves(Cast In Situ) Sqm 290.0 5.9.5 Lintels, Beams, Girders, Bressumers And Cantilevers Sqm 356.0 5.9.6 Columns, Pillers , Piers, Abutments, Sqm 471.2 Posts And Struts. 5.9.7 Stairs, (Excluding Landings) Except Spiral- Staircases. Sqm 435.7 5.9.8 Spiral Staircases (Including Landing). Sqm 450.0 5.9.9 Arches, Domes,Vaults Upto 6M Span Sqm 1141.6 5.9.10 Extra For Arches, Domes, Vaults Exceeding 6 M Span Sqm 451.3 5.9.11 Chimneys And Shafts Sqm 294.0 5.9.12 Coffer/Waffle Slab Of Any Size Or Shape As Shown In The Drawing. Sqm 1481.0 5.9.13 Well Steining Sqm 264.0 5.9.14 Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards. Sqm 643.4 5.9.15 Extra For Shuttering In Circular Work Or Any Other Geometrical Shape (20% Of Respective Centering And Shuttering Items). Sqm 0.2 5.9.16 Small Lintels Not Exceeding 1.5M Clear Span, Mouldingas Incornices, Window, Sills, Courses, Bands, Copings, Bed Plates, Anchor Blocks And The Like. Sqm 191.0 5.9.17 Cornices And Mouldings Sqm 565.0 5.9.18 Small Surfaces Such As Cantilever Ends, Brackets And Ends Of Steps, Caps And Bases To Pilasters And Columns And The Like. Sqm 529.6 5.9.19 Weather Shade, Chajjas, Corbels Etc., Including Edges. Sqm 534.2 5.9.20 Suspended Floors, Roofs, Landings, Balconies And Access Platform. With Water Proof Ply 12 Mm Thick. (Item To Be Executed With Prior Permission Of S.E. In Case Of B & R Works And From Additional Project Director In Case Of Piu Works) Sqm 575.35 5.9.21 Lintels, Beams, Columns, Girders, Bressumers And Cantilevers With Waterproof Ply 12 Mm Thick (Item To Be Executed With Prior Permission Of S.E. In Case Of B&R Works And From Additional Project Director In Case Of Piu Works) Sqm 521.2 18 5.1 5.10.1 Suspended Floors, Roofs, Landing, Beams And Balconies (Plan Area To Be Measured). Sqm 212.0 19 5.12 5.12.1 50 Mm Thick Sqm 790.0 5.12.2 40 Mm Thick Sqm 689.0 5.12.3 25 Mm Thick Sqm 598.0 20 5.16 (Note:- (1). Spacer Bars (Chairs) Shall Be Paid Separately As Shown In The Drawing And As Per Direction Of Engineer In Charge. (2). No Extra Payment Shall Be Done For Overlaps And/Or Couplers. (3). Couplers Shall Be Conforming To Is Code On “Reinforcement Couplers For Mechanical Splices Of Bars For Concrete Reinforcement - Specification”) 5.16.1 Mild Steel And Medium Tensile Steel Bars. Kg 78.0 5.16.2 Hard Drawn Steel Wire Kg 75.0 5.16.3 Cold Twisted Bars (Ctd) Kg 81.0 5.16.4 Hot Rolled Deformed Bars Kg 81.0 5.16.5 Hard Drawn Steel Wire Fabric Kg 76.0 5.16.6 Thermo-Mechanically Treated Bars. (Tmt/Tmx) Fe 500 Or More Conforming To Is 1786 Kg 80.0 21 5.22 5. 22.1 12 Mm Thick Sqm 402.0 5. 22.2 25 Mm Thick Sqm 574.0 5. 22.3 50 Mm Thick Sqm 674.0 22 5.23 5. 23.1 Non-Asbestos Fibre Cement Board 6 Mm Thick As Per Is: 14862. 5. 23.1.1 150Mm Wide. Rm 102.0 5. 23.1.2 200Mm Wide. Rm 137.0 5. 23.1.3 250Mm Wide. Rm 153.0 5. 23.2 Aluminium Fluted Strips 3.15Mm Thick. Rm 483.0 5. 23.2.1 150 Mm Wide. Rm 646.0 5. 23.2.2 200 Mm Wide. Rm 725.0 5. 23.2.3 250 Mm Wide. 5. 23.3 Stainless Steel Grade 304 Plate-1.0 Mm Thick 5. 23.3.1 150 Mm Wide. Rm 367.0 5. 23.3.2 200 Mm Wide. Rm 443.0 5. 23.3.3 250 Mm Wide. Rm 555.0 23 5.25 Note- For Item No. 5.25:-The Quantity Will Be Calculated By Multiplying The Depth Measured From The Subsoil Water Level Up To The Centre Of Gravity Of The R.C.C. Under Ubsoil Water With The Quantity Of R.C.C. In Cubic Metre Executed Under Subsoil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1 M. 0.05 M Or More Shall Be Taken As 0.1 M And Less Than 0.05 M Ignored. No Extra Payment Shall Be Made For Placing Reinforcement Or Centering & Shuttering Under Sub – Soil Water Condition 24 5.33 5. 33.1. Frame 125 Mmx 60 Mm (Double Rebate) Rm 366.0 5. 33.2. Frame 100Mmx 60 Mm (Single Rebate) Rm 339.0 5. 33.3 Frame 85Mmx 60 Mm (Single Rebate) Rm 325.0 25 6.1 6.1.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5818.0 6.1.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5626.0 26 6.2 6.2.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 6012.0 6.2.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5821.0 27 6.3 6.3.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5252.0 6.3.2 Cement Mortar 1:6 (1 Cement:6 Sand). Cum 5061.0 28 6.4 6.4.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5446.0 6.4.2 Cement Mortar 1:6 (1 Cement:6 Sand). Cum 5255.0 29 6.5 6.5.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 4347.0 6.5.2 Cement Mortar 1:6 (1 Cement: 6 Sand). Cum 4155.0 30 6.6 6.6.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 4541.0 6.6.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4350.0 31 6.7 6.7.1 Having 100 Kg / Cm2 Average Compressive Strength. 6.7.1.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5384.0 6.7.1.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5162.0 6.7.2 Having 75 Kg / Cm2 Average Compressive Strength. 6.7.2.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5271.0 6.7.2.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5049.0 6.7.3 Having 50 Kg / Cm2 Average Compressive Strength. 6.7.3.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5158.0 6.7.3.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4936.0 32 6.11 Providing Half Brick Masonry With Well Burnt Chimney Bricks In Bull Patent Trench Kiln Manufactured By Ghol Process Crushing Strength Not Less Than 40 Kg /Cm2 And Water Absorption Not More Than 15% In Superstructure Above Plinth Level And Up To Floor Two Level. 6.12.1 Cement Mortar 1:3 (1 Cement : 3 Sand) Sqm 697.0 6.12.2 Cement Mortar 1:4 (1 Cement : 4 Sand) Sqm 673.0 33 6.13 6.13.1 Cement Mortar 1:3 (1 Cement : 3 Sand) Sqm 639.0 6.13.2 Cement Mortar 1:4 (1 Cement : 4 Sand) Sqm 615.0 34 6.14 6.14.1 Cement Mortar 1:3 (1 Cement : 3 Sand) Sqm 546.0 6.14.2 Cement Mortar 1:4 (1 Cement : 4 Sand) Sqm 522.0 35 6.15 6.15.1 Having 100 Kg/Cm2 Average Compressive Strength. 6.15.1.1 Cement Mortar 1 : 3 (1 Cement : 3 Sand) Sqm 570.0 6.15.1.2 Cement Mortar 1 : 4 (1 Cement : 4 Sand) Sqm 551.0 6.15.2 Having 75 Kg/Cm2 Average Compressive Strength. 6.15.2.1 Cement Mortar 1 : 3 (1 Cement : 3 Sand) Sqm 524.0 6.15.2.2 Cement Mortar 1 : 4 (1 Cement : 4 Sand) Sqm 505.0 6.15.3 Having 50 Kg/Cm2 Average Compressive Strength. 6.15.3.1 Cement Mortar 1 : 3 (1 Cement : 3 Sand) Sqm 479.0 6.15.3.2 Cement Mortar 1 : 4 (1 Cement : 4 Sand) Sqm 459.0 36 6.24 Note: - The Quantity Will Be Calculated By Multiplying The Depth Measured From Sub - Soil Water Level Up To The Centre Of Gravity Of Brick Work Under Sub - Water With The Quantity Of Brick Work In Cum Executed Under The Sub - Soil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1 M. 0.05 M Or More Shall Be Taken As 0.1 M And Less Than 0.05 M Ignored. 37 6.27 6.27.1 Aac Masonry In Polymer Modified Mortar Cum 5052.0 38 6.29 Of Minimum 80 Mmwidth And Depth Equal To Slab/Panel Thickness Running At Center Of Load Bearing Wall/ Beam/ Supports And On Other Support As Well To Achieve Diaphragm Action As Per Is 1893:2000. The Peripheral Bond Beam Shall Have Minimum 2 Bars Of 12 Mm Dia As Longitudinal Bars Which Shall Be Held Down By Hook Made In 12 Mm Dia Vertical Bars Coming Out From Structural Beam. However Concrete In Groove And Bond Beam Shall Not Be Paid Separately But Shall Be Measured With Aac Reinforced Slab. Precast Or Lintel And Chhajja Shall Be Jointed With Cm 1:6 Or 2 To 3 Mm Thick Polymer Modified Cement Mortar As Per Astmc 1660-09 To Aac Block Masonry. Structural Steel If Used For Providing Support To The Lintels (Such As Cleat Of Angle Iron, C-Section Anchored/Hold Fasted To Column) At Column End Towards (Where Door / Window Opening Is Adjacent To The Column) Shall Not Be Paid Separately. Rate Includes All Handling, Transportation, Hire Charges Of Machineries Scaffolding And Anti- Corrosive Protective Coating On Reinforcement Inside Aac Slab / Lintel/Chhajja Etc. Complete Up To Floor Two Levels. All Reinforcement Of Peripheral Bond Beam, Grooves And Inside Aac Slab, Lintel, And Chhajja Shall Be Paid @ Sor Rate (Including Tender Percentage) Separately. Quantity Of Reinforcement Steel Provided Inside Aac Slab, Lintel And Chhajja Shall Be Ascertained On The Basis Of Manufacturer’S Certificate And Also By Random Destructive Testing Done By Engineer-In-Charge Or His Representative For Which Cost Of Samples And Testing Charges Shall Be Borne By The Contractor. Deflection & Ultimate Load Test For Aac Reinforced Roof Slab And Lintel Shall Be As Per Annex. B Of Is: 6073 -2006 And Criteria For Conformity And Sampling Shall Be As Per Clause-13 Of Is: 6073 -2006. 39 7.1 7.1.1 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4147.0 40 7.2 7.2.1 Cement Mortar 1:6 (1Cement: 6 Sand). Cum 4351.0 41 7.4 7.4.1 Square Or Rectangular Pillars Cum 213.0 7.4.2 Circular Pillars. Cum 894.0 42 7.6 7.6.1 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4603.0 7.6.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4342.0 43 7.7 7.7.1 Masonry Work (First Sort) In Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4803.0 7.7.2 Masonry Work (Second Sort) , In Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4541.0 44 7.9 7.9.1 Square Or Rectangular Pillars Cum 235.0 7.9.2 Circular Pillars. Cum 1003.0 7.9.3 Extra For Coursed Rubble Masonry With Hard Stone (First Or Second Sort) Curved On Plan For A Mean Radius Not Exceeding 6 M. Cum 384.0 45 7.26 7.26.1 Red Sand Stone: With Common Burnt Clay Bricks Of 25 Kg/Cm2 Compressive Strength. Sqm 1196.0 7.26.2 White Sand Stone With Common Burnt Clay Bricks Of 25 Kg/Cm2 Compressive Strength. Sqm 1196.0 46 7.27 7.27.1 Red Sand Stone Sqm 744.0 7.27.2 White Sand Stone Sqm 744.0 47 7.32 Note: - The Quantity Will Be Calculated By Multiplying The Depth Measured From Sub - Soil Water Level Up To The Centre Of Gravity Of Stone Work Under Sub - Water With The Quantity Of Stone Work In Cum Executed Under The Sub - Soil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1 M. 0.05 M Or More Shall Be Taken As 0.1 M And Less Than 0.05 M Ignored. 48 8.2 (A) Structural Analysis And Design And Preparation Of Shop Drawings For The Specified Design Loads Conforming To Is 875 Part Iii (The System Must Passed The Proof Test At 1.5 Times Design Wind Pressure Without Any Failure), Including Functional Design Of The Aluminum Sections For Fixing Glazing Panels Of Various Thicknesses, Aluminium Cleats, Sleeves And Splice Plates Etc. Gaskets, Screws, Toggles, Nuts, Bolts, Clamps Etc., Structural And Weather Silicone Sealants, Flashings, Fire Stop (Barrier)-Cum-Smoke Seals, Microwave Cured Epdm Gaskets For Water Tightness, Pressure Equalisation And Drainage And Protection Against Fire Hazard Including: (B) Fabricating And Supplying Serrated M.S. Hot Dip Galvanised / Aluminium Alloy Of 6005 T5 Brackets Of Required Sizes, Sections And Profiles Etc. To Accommodate 3 Dimentional Movement For Achieving Perfect Verticality And Fixing Structural Glazing System Rigidly To The Rcc/ Masonry/Structural Steel Framework Of Building Structure Using Stainless Steel Anchor Fasteners/ Bolts, Nylon Seperator To Prevent Bimetallic Contacts With Nuts And Washers Etc. Of Stainless Steel Grade 316, Of The Required Capacity And In Required Numbers. (C) Providing And Filling, Two Part Pump Filled, Structural Silicone Sealant And One Part Weather Silicone Sealant Compatible With The Structural Silicone Sealant Of Required Bite Size In A Clean And Controlled Factory / Work Shop Environment, Including Double Sided Spacer Tape, Setting Blocks And Backer Rod, All Of Approved Grade, Brand And Manufacture, As Per The Approved Sealant Design, Within And All Around The Perimeter For Holding Glass. (D) Providing And Fixing In Position Flashings Of Solid Aluminium Sheet 1 Mm Thick And Of Sizes, Shapes And Profiles, As Required As Per The Site Conditions, To Seal The Gap Between The Building Structure And All Its Interfaces With Curtain Glazing To Make It Watertight. (E) Making Provision For Drainage Of Moisture/ Water That Enters The Curtain Glazing System To Make It Watertight, By Incorporating Principles Of Pressure Equalization, Providing Suitable Gutter Profiles At Bottom (If Required), Making Necessary Holes Of Required Sizes And Of Required Numbers Etc. Complete. This Item Includes Cost Of All Inputs Of Designing, Labour For Fabricating And Installation Of Aluminium Grid, Installation Of Glazed Units, Tandp, Scaffolding And Other Incidental Charges Including Wastages Etc., Enabling Temporary Structures And Services, Cranes Or Cradles Etc. As Described Above And As Specified. The Item Includes The Cost Of Getting All The Structural And Functional Design Including Shop Drawings Checked By A Structural Designer, Dully Approved By Engineer-In-Charge. The Item Also Includes The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Structural Glazing As Specified, Cleaning And Protection Till The Handing Over Of The Building For Occupation. In The End, The Contractor Shall Provide A Water Tight Structural Glazing Having All The Performance Characteristics Etc. All Complete As Required, As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineerin- Charge. Note: - 1. The Cost Of Providing Extruded Aluminium Frames, Shadow Boxes, Extruded Aluminium Section Capping For Fixing In The Grooves Of The Curtain Glazing And Vermin Proof Stainless Steel Wire Mesh Shall Be Paid For Separately Under Relevant Items Under This Sub- Head. However, For The Purpose Of Payment, Only The Actual Area Of Structural Glazing (Including Width Of Grooves) On The External Face Shall Be Measured In Sqm. Upto Two Decimal Places.Note: 2. The Following Performance Test Are To Be Conducted On Structural Glazing System If Area Of Structural Glazing Exceeds 2500 Sqm From The Certified Laboratories Accreditated By Nabl (National Accreditation Board For Testing And Calibration Laboratories), Department Of Science And Technologies, India. Cost Of Testing Is Inclusive In The Rates. Performance Testing Of Structural Glazing System Tests To Be Conducted In The Nabl Certified Laboratories(1) Performance Laboratory Test For Air Leakage Test (-50Pa To – 300Pa) And (+50Pa To +300Pa) As Per Astm E-283-04 Testing Method For A Range Of Testing Limit 1 To 200 Mvhr”(2) Static Water Penetration Test. (50Pa To 1500Pa) As Per Astme- 331-09 Testing Method For A Range Upto 2000 Ml.”(3) Dynamic Water Penetration (50Pa To 1500Pa) As Per Aama 501.01-05 Testing Method For A Range Upto 2000 Ml”(4) Structural Performance Deflection And Deformation By Static Air Pressure Test (1.5 Times Design Wind Pressure Without Any Failure) As Per Astme-330-10 Testing Method For A Range Upto 50 Mm”(5) Seismic Movement Test (Upto 30 Mm) As Per Aama 501.4-09 Testing Method For Qualitative Test” Tests To Be Conducted On Site (6) Onsite Test For Water Leakage For A Pressure Range 50 Kpa To 240 Kpa (35Psi) Upto 2000Ml” 49 8.3 (I) Coloured Tinted Float Glass 6Mm Thick Substrate With Reflective Soft Coating On Face # 2, + 12Mm Airgap + 6Mm Heat Strengthened Clear Glass Of Approved Make Having Properties As Visible Light Transmittance (Vlt) Of 25 To 35 %, Light Reflection Internal 10 To 15%, Light Reflection External 10 To 20 %, Shading Coefficient (0.25- 0.28) And U Value Of 3.0 To 3.3 W/M2 Degree K Etc. The Properties Of Performance Glass Shall Be Decided By Technical Sanctioning Authority As Per The Site Requirement. 50 8.5 The Insulation Layer Shall Have Facing (Factory Bonded On Surface # 1 Of The Fibre Glass Insulation Layer), Of Black Non- Woven Fibre Glass Tissue Of Nominal Thickness 0.5 Mm And Nominal Mass Not Less Than 60 Gm/Sqm, Made Of Randomly Oriented Glass Fibres Distributed In A Binder By A Wet-Lay Process Including Fixing 1.5 Mm Thick Solid Aluminum Sheet Backing Using, 6 Mm Thick Cement Board Including Ss Rivets, Nuts, Bolts,Washers Etc Complete. 51 8.6 %, Light Reflection Internal 10 To 15%, Light Reflection External 10 To 20 %, Shading Coefficient (0.25- 0.28) And U Value Of 3.0 To 3.3 W/M2 Degree K Etc. The Properties Of Performance Glass Shall Be Decided By Technical Sanctioning Authority As Per The Site Requirement. 52 8.7 A) Structural Analysis And Design And Preparation Of Shop Drawings For Pressure Equalisation Or Rain Screen Principle As Required, Proper Drainage Of Water To Make It Watertight Including Checking Of All The Structural And Functional Design. B) Providing, Fabricating And Supplying And Fixing Panels Of Aluminium Composite Panel Cladding In Pan Shape In Metalic Colour Of Approved Shades.The Aluminium Composite Panel Cladding Sheet Shall Be Coil Coated, With Kynar 500 Based Pvdf / Fluoropolymer Resin Coating Of Approved Colour And Shade On Face # 1 And Polymer (Service) Coating On Face # 2 As Specified Using Stainless Steel Screws, Nuts, Bolts, Washers, Cleats, Weather Silicone Sealant, Backer Rods Etc. C) The Fastening Brackets Of Aluminium Alloy 6005 T5 / Ms With Hot Dip Galvanised With Serrations And Serrated Washers To Arrest The Wind Load Movement, Fasteners, Ss 316 Pins And Anchor Bolts Of Approved Make In Ss 316, Nylon Separators To Prevent Bi-Metallic Contacts All Complete Required To Perform As Per Specification And Drawing The Item Includes Cost Of All Material And Labour Component, The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Curtain Wall With Aluminium Composite Panel Cladding, Cleaning And Protection Of The Curtain Wall With Aluminium Composite Panel Cladding Till The Handing Over Of The Building For Occupation. Base Frame Work For Acp Cladding Is Payable Under The Relevant Aluminium Items. The Contractor Shall Provide Curtain Wall With Aluminium Composite Panel Cladding, Having All The Performance Characteristics All Complete, As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineer- In-Charge. However, For The Purpose Of Payment, Only The Actual Area On The External Face Of The Curtain Wall With Aluminum Composite Panel Cladding (Including Width Of Groove) Shall Be Measured In Sqm. Upto Two Decimal Places. 4 Mm Thick Alumminium Composite Pannel Material Consisting Of 3 Mm Thick Fr Grade Mineral Core Sandwiched Between Two Alumminium Sheets (Each 0.5Mm Thick) Sqm 3800.0 4 Mm Thick Alumminium Composite Pannel Material Consisting Of 3.5 Mm Thick Fr Grade Mineral Core Sandwiched Between Two Alumminium Sheets (Each 0.25Mm Thick) Sqm 3556.0 3 Mm Thick Alumminium Composite Pannel Material Consisting Of 2.5 Mm Thick Fr Grade Mineral Core Sandwiched Between Two Alumminium Sheets (Each 0.25Mm Thick) Sqm 3312.0 53 9.1 9.1.1 Second Class Teak Wood Cum 90618.0 9.1.2 Sal Wood Cum 71309.0 9.1.3 Kiln Head Wood Seasoned And Chemically Treated Hard Wood (Haldu, Kail, Bija Wood.) Cum 72744.0 9.1.4 Factory Made Kiln Seasoned, Chemically Treated, Finger Jointed At Spacing Not Closer Than 50 Cm, 2Nd Class Hard Wood 9.1.4.1 Frame Of Size 100Mmx60Mm Single Or Double Rebate Meter 389.0 9.1.4.2 Frame Of Size 120Mmx60Mm Double Rebate. Meter 457.0 54 9.3 9.3.1 Sal Wood Cum 76229.0 9.3.2 Kiln Seasoned And Chemically Treated Hardwood Haldu, Kail, Bija Wood. Cum 77538.0 9.3.3 Factory Made Kiln Seasoned, Chemically Treated, Finger Jointed At Spacing Not Closer Than 50 Cm, 2Nd Class Hard Wood. Cum 64833.0 55 9.5 9.5.1 Second Class Teak Wood 9.5.1.1 35 Mm Thick Shutters Sqm 2776.0 9.5.1.2 30 Mm Thick Shutters Sqm 2448.0 9.5.2 Kiln Seasoned And Chemically Treated Hardwood Haldu, Kail, Bija Wood. 9.5.2.1 35 Mm Thick Shutters Sqm 2205.0 9.5.2.2 30 Mm Thick Shutters Sqm 1956.0 9.5.3 Kiln Seasoned Selected Planks Of Sheesham Wood. 9.5.3.1 35 Mm Thick Shutters Sqm 2060.0 9.5.3.2 30 Mm Thick Shutters Sqm 1816.0 9.5.4 Factory Made Kiln Seasoned Chemically Treated And Finger Jointed At Spacing Not Closer Than 50Cm, 2Nd Class Hard Wood Shutters 9.5.4.1 35 Mm Thick Sqm 1089.0 9.5.4.2 30 Mm Thick Sqm 969.0 56 9.6 9.6.1 Second Class Teak Wood Sqm 2215.0 9.6.2 Kiln Seasoned And Chemically Treated Hardwood Haldu, Kail, Bija Wood. Sqm 1763.0 9.6.3 15Mm Thick Factory Made Kiln Seasoned, Chemically Treated And Finger Jointed At Spacing Not Closer Than 50Cm, 2Nd Class Hard Wood. Sqm 971.0 9.6.4 Ply Wood 5 Ply, 9 Mm Thick : 9.6.4.1 Decorative Plywood Both Side Decorative Veneer (Type - I) Conforming To Is 1328 Bwr Type. Sqm 1439.0 9.6.4.2 Decorative Plywood One Side Decorative Veneer And Commercial Veneer On Other Face (Type 1) Conforming To Is 1328 Bwr Type Sqm 1369.0 9.6.5 Ply Wood 7 Ply, 9 Mm Thick : 9.6.5.1 Decorative Plywood Both Side Decorative Veneer (Type - I) Conforming To Is 1328 Bwr Type. Sqm 1861.0 9.6.5.2 Decorative Plywood One Side Decorative Veneer And Commercial Veneer On Other Face (Type 1) Conforming To Is 1328 Bwr Type Sqm 1650.0 9.6.6 Particle Board 12 Mm Thick 9.6.6.1 Plain Particle Board Flat Pressed, 3 Layer Or Graded Wood Particle Board Medium Density Grade I, Is: 3087 Marked. Sqm 791.0 9.6.6.2 Veneered Flat Pressed Three Layer Or Graded Wood Particle Board With Commercial Veneering On Both Sides Conforming To Is: 3097, Grade I. Sqm 1087.0 9.6.6.3 Pre-Laminated Particle Board With Sqm 1333.0 Decorative Lamination On One Side And Balancing Lamination On Other Side, Grade I, Type Ii Is: 12823 Marked. 9.6.6.4 Pre-Laminated Particle Board With Decorative Lamination On Both Sides, Grade I, Type Ii, Is: 12823 Marked. Sqm 1390.0 9.6.6.5 Coir Veneer Board (Conforming To Is 14842) 12 Mm Thick Sqm 1298.0 9.6.7 Float Glass Panes 9.6.7.1 4 Mm Thick Glass Pane (Weight Not Less Than 10 Kg/Sqm) Sqm 973.0 9.6.7.2 5 Mm Thick Glass Pane (Weight Not Less Than 12.5 Kg/Sqm) Sqm 1046.0 9.6.8 Fly Proof Stainless Steel Grade 304 Wire Gauge With 0.5 Mm Dia. Wire And 1.4 Mm Wide Aperture With Matching Wood Beading Sqm 1532.0 9.6.8.1 4Mm To 5Mm Thick Integral Pvc Form Sheet With Celluka Finish Surface On Both Side With Density Not Less Than 600 Kg/Cum Sqm 580.0 9.6.8.2 4Mm To 5Mm Thick Laminated Pvc Form Sheet With Density Not Less Than 600 Kg/Cum, Laminated On Both Sides By 0.12 Mm Thick Laminated Sheet With Density Not Less Than 1400 Kg/Cum Sqm 754.0 57 9.7 9.7.1 12Mm Thick Plain Grade - 1, Medium Density Flat Pressed Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt - I Is : 3087 Marked Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 : Sqm 2717.0 9.7.2 12 Mm Thick Pre-Laminated Particle Board (Decorative Lamination On Both Sides) Grade - 1, Medium Density Flat Pressed, Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt - I, Conforming To Is : 3087 Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 And Pre- Lamination Conforming To Is : 12823 Grade 1, Type - Ii Marked: Sqm 2868.0 9.7.3 12 Mm Thick One Side Pre-Laminated Particle Board (Decorative Lamination On One Side And Other Sides Balancing Lamination) Grade - 1 Medium Density Flat Pressed, Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt-1 Conforming To Is : 3087 Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 And Prelamination Conforming To Is : 12823 Grade -1, Type Ii Marked: Sqm 2775.0 58 9.8 9.8.1 Second Class Teak Wood 9.8.1.1 35 Mm Thick Sqm 3408.0 9.8.1.2 30 Mm Thick Sqm 3033.0 9.8.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood 9.8.2.1 35 Mm Thick Sqm 2758.0 9.8.2.2 30 Mm Thick Sqm 2474.0 9.8.3 Kiln Seasoned Selected Planks Of Sheesham Wood. 9.8.3.1 35 Mm Thick Sqm 2594.0 9.8.3.2 30 Mm Thick Sqm 2331.0 9.8.4 Factory Made Kiln Seasoned Chemically Treated And Finger Jointed At Spacing Not Closer Than 50Cm, 2Nd Class Hard Wood Shutters 9. 8.4.1 30 Mm Thick Shutters Sqm 1469.0 9. 8.4.2 35 Mm Thick Shutters Sqm 1589.0 59 9.1 9.10.1 5 Mm Thick Instead Of 4 Mm Thick. Sqm 73.0 9.10.2 10 To 12 Mm Float Glass Sqm 132.0 9.10.3 5.5 Mm Safety Glass Sqm 400.0 9.10.4 10-12Mm Safety Glass Sqm 960.0 60 9.13 Deduct For Not Providing Hinges In Doors, Windows Or Clerestory Window Shutters With : 9.14.1 Stainless Steel Butt Hinges With Stainless Steel Screws For 2Nd Class Teak Wood And Other Class Of Wood Shutters. Sqm 170.0 9.14.2 Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size For 2Nd Class Teak Wood And Other Class Of Wood Shutters. Sqm 53.0 61 9.15 9.15.1 Panelled Or Panelled And Glazed Shutters : 9.15.1.1 Using Isi Marked Anodised Aluminium Butt Hinges With Necessary Screws. Sqm 2736.0 9.15.1.2 Using Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2753.0 9.15.2 Glazed Shutters : 9.15.2.1 Second Class Teak Wood Including Isi Marked Anodised Aluminium Butt Hinges With Necessary Screws. Sqm 2815.0 9.15.2. 2Nd Class Teak Wood Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2759.0 62 9.16 9.16.1 12 Mm Thick Sqm 555.0 9.16.2 18 Mm Thick Sqm 654.0 63 9.17 9.17.1 18 Mm Thick Sqm 1270.0 9.17.2 25 Mm Thick Sqm 1383.0 64 9.18 9.18.1 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. Sqm 2600.0 9.18.2 30 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. Sqm 2370.0 9.18.3 25 Mm Thick (For Cupboard) Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges Is: 3818 Marked With Necessary Screws. Sqm 2119.0 65 9.19 9.19.1 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. Sqm 1622.0 9.19.2 30 Mm Thick Including Isi Marked Sqm 1564.0 Stainless Steel Butt Hinges With Necessary Screws. 9.19.3 25Mm Thick (For Cupboard) Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 1533.0 66 9.22 9.22.1 Rectangular Or Square. Sqm 157.0 9.22.2 Circular. Sqm 244.0 67 9.25 9.25.1 35 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.25.1.1 Second Class Teak Wood. Sqm 3174.0 9.25.1.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2599.0 9.25.1.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2452.0 9.25.2 35 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size. 9.25.2.1 Second Class Teak Wood. Sqm 3291.0 9.25.2.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2716.0 9.25.2.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2569.0 9.25.3 30 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.25.3.1 Second Class Teak Wood. Sqm 2797.0 9.25.3.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2306.0 9.25.3.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2179.0 9.25.4 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size. 9.25.4.1 Second Class Teak Wood. Sqm 2914.0 9.25.4.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2423.0 9.25.4.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2296.0 68 9.26 9.26.1 35 Mm Thick Shutters Sqm 2427.0 9.26.2 30 Mm Thick Shutters Sqm 2102.0 69 9.28 9.28.1 25 Mm Long Each 16.0 9.28.2 32 Mm Long Each 18.0 9.28.3 40 Mm Long Each 21.0 9.28.4 50 Mm Long Each 25.0 9.28.5 60 Mm Long Each 28.0 70 9.29 9.29.1 40 Mm Thick. Sqm 5407.0 9.29.2 25 Mm Thick. Sqm 3469.0 9.29.3 20 Mm Thick Sqm 2802.0 9.29.4 12 Mm Thick Sqm 1768.0 71 9.3 9.30.1 12 Mm Thick Sqm 1174.0 9.30.2 18 Mm Thick Sqm 1410.0 9.30.3 25 Mm Thick Sqm 1525.0 72 .9.32 73 9.34 9.34.1 18 Mm Thick Sqm 1626.0 9.34.2 25 Mm Thick Sqm 1741.0 74 9.35 9.35.1 2Nd Class Teak Wood 9.35.1.1 50X12 Mm Metre 102.0 9.35.1.2 50 X 20 Mm Metre 147.0 9.35.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. 9.35.2.1 50X12 Mm Metre 85.0 9.35.2.2 50X20 Mm Metre 119.0 75 9.39 9.39.1 Non Decorative Veneer On Both Sides. Metre 34.0 9.39.2 Particle Board With Decorative Veneering On Both Sides. Metre 102.0 76 9.41 9.41.1 12 Mm Dia. Metre 289.0 9.41.2 20 Mm Dia. Metre 377.0 9.41.3 25 Mm Dia. Metre 382.0 77 9.42 9.42.1 20 Mm Dia (Heavy Type) Metre 127.0 9.42.2 25 Mm Dia (Heavy Type) Metre 141.0 78 9.43 9.43.1 Fixed To Steel Windows By Welding. Kg 91.0 9.43.2 Fixed To Openings /Wooden Frames With Rawl Plugs Screws Etc. Kg 100.0 79 9.46 9.46.1 With 2Nd Class Teak Wood Beading 62X19 Mm. Sqm 1000.0 9.46.2 With 12 Mm Mild Steel U Beading. Sqm 681.0 80 9.5 9.50.1 125X65X2.12 Mm Each 30.0 9.50.2 100X58X1.90 Mm Each 23.0 9.50.3 75X47X1.70 Mm Each 18.0 9.50.4 50X37X1.50 Mm Each 10.0 81 9.51 9.51.1 125X90X4.00 Mm Each 53.0 9.51.2 100X75X3.50 Mm Each 35.0 9.51.3 75X60X3.10 Mm Each 21.0 9.51.4 50X40X2.50 Mm Each 13.0 82 9.52 9.52.1 125X65X2.12 Mm Each 32.0 9.52.2 100X58X1.90 Mm Each 23.0 9.52.3 75X47X1.70 Mm Each 17.0 9.52.4 50X37X1.50 Mm Each 10.0 83 9.53 9.53.1 150X125X27X2.80 Mm Each 58.0 9.53.2 125X125X27X2.80 Mm Each 55.0 9.53.3 100X125X27X2.80 Mm Each 46.0 9.53.4 75X100X20X2.24 Mm Each 39.0 84 9.54 9.54.1 150 Mm Each 169.0 9.54.2 125 Mm Each 163.0 9.54.3 100 Mm Each 131.0 85 9.55 9.55.1 150 Mm Each 174.0 9.55.2 125 Mm Each 163.0 9.55.3 100 Mm Each 137.0 86 9.56 9.56.1 Overall Width 35 Mm. Metre 133.0 9.56.2 Overall Width 50 Mm. Metre 138.0 9.56.3 Overall Width 65 Mm. Metre 141.0 87 9.57 9.57.1 300X16 Mm Each 170.0 9.57.2 250X16 Mm Each 157.0 88 9.58 9.58.1 250X10 Mm Each 68.0 9.58.2 200X10 Mm Each 60.0 9.58.3 150X10 Mm Each 42.0 9.58.4 100X10 Mm Each 35.0 89 0.6 9.60.1 300X20X6 Mm Each 72.0 9.60.2 250X20X6 Mm Each 67.0 90 9.61 9.61.1 125 Mm Each 27.0 9.61.2 100 Mm Each 25.0 9.61.3 75 Mm Each 24.0 91 9.62 9.62.1 150 Mm Each 23.0 9.62.2 115 Mm Each 20.0 9.62.3 90 Mm Each 17.0 92 9.63 9.63.1 300 Mm Weighing Not Less Than 200 Gms. Each 40.0 9.63.2 250 Mm Weighing Not Less Than 150 Gms. Each 34.0 9.63.3 200 Mm Weighing Not Less Than 120 Gms. Each 28.0 93 9.65 9.65.1 300X16 Mm Each 389.0 9.65.2 250X16 Mm Each 326.0 94 9.66 9.66.1 250X10 Mm Each 148.0 9.66.2 200X10 Mm Each 93.0 9.66.3 150X10 Mm Each 71.0 9.66.4 100X10 Mm Each 50.0 95 9.68 9.68.1 300X20X6 Mm Each 211.0 9.68.2 250X20X6 Mm Each 173.0 96 9.69 9.69.1 125 Mm Each 60.0 9.69.2 100 Mm Each 54.0 9.69.3 75 Mm Each 48.0 97 9.7 9.70.1 150 Mm Each 37.0 9.70.2 115 Mm Each 33.0 9.70.3 90 Mm Each 26.0 98 9.71 9.71.1 300 Mm Weighing Not Less Than 200 Gms. Each 79.0 9.71.2 250 Mm Weighing Not Less Than 150 Gms. Each 61.0 9.71.3 200 Mm Weighing Not Less Than 120 Gms. Each 49.0 99 9.73 9.73.1 125X64X1.90 Mm Each 67.0 9.73.2 100X58X1.90 Mm Each 59.0 9.73.3 75X47X1.80 Mm Each 39.0 9.73.4 50X37X1.50 Mm Each 25.0 100 9.74 9.74.1 125X64X2.50 Mm Each 76.0 9.74.2 100X60X2.50 Mm Each 60.0 9.74.3 75X50X2.50 Mm Each 46.0 101 9.77 9.77.1 125X85X5.5 Mm (Heavy Type) Each 456.0 9.77.2 125X70X4 Mm (Ordinary Type) Each 148.0 9.77.3 100X85X5.5 Mm (Heavy Type) Each 387.0 9.77.4 100X70X4 Mm (Ordinary Type) Each 117.0 9.77.5 75X65X4 Mm (Heavy Type) Each 145.0 9.77.6 75X40X2.5 Mm (Ordinary Type) Each 74.0 9.77.7 50X40X2.5 Mm (Ordinary Type) Each 32.0 102 9.78 9.78.1 150X125X27X5 Mm Each 385.0 9.78.2 125X125X27X5 Mm Each 345.0 9.78.3 100X125X27X5 Mm Each 304.0 9.78.4 75X100X20X3.2 Mm Each 239.0 103 9.79 9.79.1 400X10 Mm Each 400.0 9.79.2 250X10 Mm Each 329.0 9.79.3 200X10 Mm Each 261.0 9.79.4 150X10 Mm Each 221.0 9.79.5 100X10 Mm Each 142.0 104 9.8 9.80.1 300X16X5 Mm Each 237.0 9.80.2 250X16X5 Mm Each 225.0 105 9.81 9.81.1 125 Mm Each 205.0 9.81.2 100 Mm Each 181.0 9.81.3 75 Mm Each 141.0 106 9.82 9.82.1 300X16Mm Each 407.0 9.82.2 250X16Mm Each 374.0 107 9.87 9.87.1 40 Mm Each 144.0 9.87.2 50 Mm Each 150.0 9.87.3 65 Mm Each 162.0 9.87.4 75 Mm Each 185.0 108 9.39 9.91.1 300 Mm Weighing Not Less Than 330 Gms Each 184.0 9.91.2 250 Mm Weighing Not Less Than 280 Gms Each 147.0 9.91.3 200 Mm Weighing Not Less Than 240 Gms Each 136.0 109 9.92 9.92.1 150 Mm Each 115.0 9.92.2 115 Mm Each 94.0 9.92.3 90 Mm Each 80.0 110 9.99 9.99.1 Size 40 Mm Each 144.0 9.99.2 Size 50 Mm Each 156.0 9.99.3 Size 65 Mm Each 167.0 9.99.4 Size 75 Mm Each 196.0 111 9.101 9.101.1 300X16Mm Each 268.0 9.101.2 250X16Mm Each 245.0 112 9.102 9.102.1 400X10Mm Each 260.0 9.102.2 300X10Mm Each 198.0 9.102.3 250X10Mm Each 164.0 9.102.4 200X10 Mm Each 113.0 9.102.5 150X10 Mm Each 91.0 9.102.6 100X10 Mm Each 73.0 113 9.1 9.103.1 300X16X5Mm Each 255.0 9.103.2 250X16X5Mm Each 243.0 114 9.104 115 9.105 9.105.1 125 Mm Each 241.0 9.105.2 100 Mm Each 206.0 9.105.3 75 Mm Each 182.0 116 9.106 117 9.107 9.107.1 300 Mm Weighing Not Less Than 330 Gms Each 207.0 9.107.2 250 Mm Weighing Not Less Than 280 Gms Each 178.0 9.107.3 200 Mm Weighing Not Less Than 240 Gms Each 149.0 118 9.108 Note:- Aluminum Hinges Shall Not Be Used In Wooden Shutters. 9.108.1 125X75X4 Mm Each 115.0 9.108.2 125X63X4 Mm Each 108.0 9.108.3 100X75X4 Mm Each 95.0 9.108.4 100X63X4 Mm Each 93.0 9.108.5 100X63X3.2 Mm Each 90.0 9.108.6 75X63X4 Mm Each 77.0 9.108.7 75X63X3.2 Mm Each 75.0 9.108.8 75X45X3.2 Mm Each 67.0 119 9.109 9.109.1 300X16 Mm Each 241.0 9.109.2 250X16 Mm Each 195.0 120 9.11 9.110.1 400X10Mm Each 123.0 9.110.2 300X10 Mm Each 114.0 9.110.3 250X10 Mm Each 102.0 9.110.4 200X10 Mm Each 82.0 9.110.5 150X10 Mm Each 69.0 9.110.6 100X10 Mm Each 55.0 121 9.111 122 9.112 123 9.113 9.113.1 125 Mm Each 75.0 9.113.2 100 Mm Each 55.0 9.113.3 75 Mm Each 46.0 124 9.114 9.114.1 Single Rubber Stopper Each 35.0 9.114.2 Twin Rubber Stopper Each 86.0 125 9.115 126 9.116 127 9.117 128 9.118 9.118.1 125X34X24 Mm Weighing Not Less Than 23 Gms. Each 44.0 9.118.2 150X34X24 Mm Weighing Not Less Than 26 Gms. Each 48.0 129 9.119 9.119.1 75X60X10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms. Each 62.0 9.119.2 100X75X10 Mm Fitted With 5.5 Mm Dia Ms Bright Bar Rod Weighing Not Less Than 53 Gms. Each 82.0 130 9.12 9.120.1 152X42X18 Mm Weighing Not Less Than 60 Gms. Each 87.0 9.120.2 202X42X18 Mm Weighing Not Less Than 78 Gms. Each 106.0 131 9.121 132 9.122 133 9.123 9.123.1 35 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.123.1.1 Second Class Teak Wood. Sqm 3583.0 9.123.1.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 3008.0 9.123.1.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2862.0 9.123.2 35 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size. 9.123.2.1 Second Class Teak Wood. Sqm 3700.0 9.123.2.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 3125.0 9.123.2.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2979.0 9.123.3 30 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.123.3.1 Second Class Teak Wood. Sqm 3206.0 9.123.3.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2715.0 9.123.3.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2589.0 9.123.4 30 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.123.4.1 Second Class Teak Wood. Sqm 3323.0 9.123.4.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2832.0 9.123.4.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2706.0 134 9.124 9.124.1 With 2Nd Class Teak Wood Beading 62X19 Mm. Sqm 1689.0 9.124.2 With 12 Mm Mild Steel U Beading. Sqm 1370.0 135 9.126 136 9.127 137 9.128 138 9.129 9.129.1 Triple Strip Vertical Type. Each 28.0 9.129.2 Double Strip (Horizontal Type). Each 23.0 139 9.131 9.131.1 300Mm Long Each Set 209.0 9.131.2 450Mm Long Each Set 256.0 9.131.3 500Mm Long Each Set 302.0 140 9.132 141 9.133 9.133.1 Marine Plywood Conforming To Is: 710 Sqm 1591.0 9.133.2 Fire Retardant Plywood Conforming To Is: 5509 Sqm 1660.0 142 9.134 9.134.1 1.5 Mm Thick. Sqm 851.0 9.134.2 1.0 Mm Thick. Sqm 691.0 143 9.135 144 9.136 9.136.1 With Decorative Veneering On One Side And Commercial Veneering On Other Side. Sqm 1433.0 9.136.2 With Non Decorative Veneering On Both Sides. Sqm 1322.0 145 9.137 146 9.138 9.138.1 12 Mm Thick. Sqm 919.0 9.138.2 18 Mm Thick. Sqm 1161.0 9.138.3 25 Mm Thick. Sqm 1230.0 147 9.139 148 9.14 9.140.1 18 Mm Thick Sqm 1493.0 9.140.2 25 Mm Thick Sqm 2017.0 149 9.143 25Mm To 40Mm Thick: Pre-Laminated With Decorative Lamination On Both Side Exterior Grade - I Mdf Board 12 Mm Thick Confirming To Is:14587 150 9.145 9.145.1 Board 12 Mm Thick Sqm 811.0 9.145.2 Board 18 Mm Thick Sqm 943.0 151 9.146 9.146.1 18 Mm Thick Sqm 1055.0 9.146.2 25 Mm Thick Sqm 1420.0 152 9.158 9.158.1 Extruded Section Profile Size 48X40 Mm. Metre 203.0 9.158.2 Extruded Section Profile Size 42X50 Mm. Metre 208.0 153 9.159 154 9.161 155 9.165 156 9.166 9.166.1 Plain Pvc Door Shutters. Sqm 2026.0 9.166.2 Pre Laminated Pvc Door Shutters. Sqm 2490.0 157 9.167 158 9.168 Non Decorative Finish. Sqm 2026.0 Decorative Finish (Both Side Wood Grained Finish). Sqm 2432.0 159 9.175 160 9.176 9.176.1 Non Decorative Finish (Matt Finish). Sqm 2037.0 9.176.2 Decorative Finish (Wood Grained Finish). Sqm 2142.0 161 9.177 162 9.182 163 9.183 164 9.184 165 9.185 166 9.186 167 9.187 9.187.1 Casement Window (Outward/Inward Opening) With Hinge System. 9.187.1.1 Frame (50 Mm X 50Mm) Metre 422.0 9.187.1.2 Sash (Style And Rail) (62 Mm X 34 Mm) Metre 403.0 9.187.1.3 Mullion (Intermediate Section) (66Mm X 50 Mm) Metre 434.0 9.187.1.4 ‘T Profile (One Vertical Length In Between Two Shutters) (24Mm X 34.5Mm) Metre 99.0 9.187.1.5 Glazing Bead (12Mm X 18Mm) Metre 130.0 9.187.2 Casement Window (With Friction Hinge And Outward Opening) 9.187.2.1 Casement Frame (67Mm X 62Mm) Metre 495.0 9.187.2.2 Casement Window Sash/Mullion (67Mm X75Mm) (Style, Rail And Intermediate Section) Metre 519.0 9.187.2.3 Casement Glazing Bead (35Mm X 18 Mm) Metre 178.0 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67Mm X 52Mm) Metre 9.187.3.2 Sliding Window Sash (60Mm X 44Mm) Metre 529.0 9.187.3.3 Sliding Interlock For Window (One Vertical Length In Each Shutter)(45.5 Mm X 28 Mm) Metre 139.0 9.187.3.4 Sliding Glazing Bead (35 Mm X 18 Mm) Metre 178.0 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67Mm X 52Mm) Metre 539.0 9.187.4.2 Sliding Door Sash (80Mm X 44Mm) Metre 653.0 9.187.4.3 Sliding Interlock For Door (One Vertical Length In Each Shutter) (45.5 Mm X 28 Mm) Metre 139.0 9.187.4.4 Sliding Glazing Bead (35 Mm X 18 Mm) Metre 178.0 168 9.188 9.188.1 200 X 19 X 1.9 Mm Each 321.0 9.188.2 250 X 19 X 1.9 Mm Each 369.0 9.188.3 300 X 19 X 1.9 Mm Each 462.0 9.188.4 350 X 19 X 1.9 Mm Each 526.0 9.188.5 400 X 19 X 1.9 Mm Each 636.0 169 9.189 170 9.191 171 9.192 172 9.193 173 9.194 Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. (Single / Double Glass Panes And Silicon Sealant Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerancein Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 0.75 Sqm.) 9.193.1 Casement Window Single Panel With S.S. Friction Hinges (300 X 19 X 1.9 Mm), Made Of (Small Series) Frame 47 X 50 Mm & Sash 47 X 68 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glass Pane Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 0.75 Sqm.) Sqm 6798.0 9.193.2 Casement Window Double Panels With S.S. Friction Hinges (300 X 19 X 1.9 Mm) Made Of (Small Series) Frame 47 X 50 Mm, Sash 47 X 68 Mm & Mullion 47 X 68 Mm All Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Above 0.75 Sqm Upto 1.50 Sqm). Sqm 6221.0 9.193.3 Casement Window Double Panels With Top Fixed With S.S. Friction Hinges (350 X 19 X 1.9 Mm) Made Of (Small Series) Frame 47 X 50 Mm, Sash 47 X 68 Mm & Mullion 47 X 68 Mm All Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 2.50 Sqm). Sqm 4842.0 9.193.4 Casement Window Single Panel With S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 60 Mm & Sash 67 X 80 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Sqm 6681.0 9.193.5 Casement Window Duble Panel With S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 60 Mm & Sash 67 X 80 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.50 Sqm.) Sqm 6942.0 9.193.6 Casement Cum Fixed Panel Window Having Both And Single Casement Panel, Middle Fixed Panels And At Top Completely Fixed Ventilator With S.S. Friction Hinges (350 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 60 Mm & Sash 67 X 80 Mm & Mullion 67 X 80 All Having Wall Thickness Of 2.3 ±0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 3.00 Sqm. Upto 5.00 Sqm.) Sqm 5290.0 174 9.0 194.1 Fixed Window / Ventilator Made Of (Small Series) Frame 47 X 50 Mm & Mullion 47 X 68 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Upto 0.75 Sqm.) Sqm 4860.0 175 9.195 9.195.1 Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Mm & Sash 67 X 110 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Upto 2.00 Sqm). 9.195.2 Casement Door With Top Hung Ventilator With 3D And S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 64 Mm, Sash 67 X 110 Mm & Mullion 67 X 80 Mm All Having Wall Thickness Of 2.3 ±.0.2 Mm And Single Glazing Bead /Double Glazing Bead Of Appropriate Dimension. (Area Of Door Upto 2.50 Sqm). 176 9.196 Note: - For Upvc Frame, Sash And Mullion Extruede Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. 9.196.1 Two Track Two Panels Sliding Window Made Of Frame 52 X 44 Mm &Sash 32 X 60Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 1.75 Sqm) Sqm 5060.0 9.196.2 Three Track Three Panels Sliding Window With Fly Proof Ss Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of Frame 92 X 44 Mm & Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension (Area Of Window Upto 1.75 Sqm). Sqm 6880.0 9.196.3 Two Track Two Panels Sliding Window Made Of Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension (Area Of Window Above 1.75 Sqm Upto 2.50 Sqm). Sqm 5134.0 9.196.4 Three Track Three Panels Sliding Window With Fly Proof Ss Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of Frame 92 X 44 Mm & Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension (Area Of Glazed & One No. Wire Mesh Panels) Made Of Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead/Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.75 Sqm). Sqm 6371.0 9.196.5 Three Track Three Panels Sliding Window Made Of Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.75 Sqm) Sqm 5913.0 177 9.197 Note: - For Upvc Frame, Sash And Mullion Extruede Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. 9.197.1 Two Track Two Panels Sliding Window Made Of Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 2.50 Sqm Upto 4.00 Sqm). Sqm 4332.0 9.197.2 Two Track Four Panels Sliding Window Made Of Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 4.00 Sqm Upto 8.00 Sqm). Sqm 3532.0 178 9.198 9.198.1 Two Track Two Panels Sliding Door Made Of Frame 67 X 50 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 2.00 Sqm Upto 10.00 Sqm). Sqm 3676.0 9.198.2 Two Track Four Panels Sliding Door Made Of Frame 67 X 50 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 8.00 Sqm Upto10.00 Sqm). Sqm 3810.0 9.198.3 Three Track Three Panels Sliding Door Made Of Frame 116 X 45 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead/ Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 5.00 Sqm) Sqm 4361.0 9.198.4 Three Track Three Panels Sliding Door With Fly Proof S.S Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of Frame 116 X 45 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 2.00 Sqm Upto 5.00 Sqm) Sqm 5617.0 179 9.199 180 9.2 9.200.1 24 To 25 Mm Thick Plain Solid Pvc Flush Door Shutter 9.200.2 28 To 30 Mm Thick Plain Solid Pvc Flush Door Shutter 181 9.201 9.201.1 1Mm Thick Laminated Sheet Sqm 3693.0 9.201.2 0.12 Mm Thick Laminated Sheet Sqm 3461.0 182 9.202 9.202.1 35Mm Thick Including 4 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3339.0 9.202.2 35Mm Thick Including 3 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3171.0 9.202.3 25Mm Thick (For Cupboard) Including 3 Nos. 75Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 3005.0 183 9.203 9.203.1 35Mm Thick Including 4 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary. Sqm 1953.0 9.203.2 30Mm Thick Including 3 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 1772.0 25Mm Thick Including 3 Nos. 100Mm Long, Screws. Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 1532.0 184 9.204 185 9.213 9.213.1 35 Mm Thick Including 4 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 2775.0 9.213.2 30 Mm Thick Including 3 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 2675.0 9.213.3 25Mm Thick (For Cupboard) Including 3 Nos. 75 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2575.0 186 9.214 9.214.1 35 Mm Thick Including 4 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3650.0 9.214.2 30 Mm Thick Including 3 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws.Screws. Sqm 3550.0 9.214.3 25Mm Thick (For Cupboard) Including 3 Nos. 75 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 3450.0 187 9.215 9.215.1 35 Mm Thick Including 4 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3121.0 9.215.2 30 Mm Thick Including 3 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3021.0 9.215.3 25Mm Thick (For Cupboard) Including 3 Nos. 75 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2921.0
Contract Date: Jun 24, 2026 Contract Value : 20.40 Lakh
Government Departments No of Bidders 3
Madhya Pradesh View Result →
49.
Coal and Mines #11032165 AOC
maintenance and repair And Other Miscellaneous Civil Works At Rg Ocm-I Chp, Rg-Iii Area.-Clearing light jungle / Shrub jungle 15000.000 3.80 57000.00 Sqm 3.4 2 Earth work excavation for foundations and depositing on bank for all lifts and with an initial lead up to 50m including all operational, incidental, labour charges such as shoring, sheeting, planking, strutting, etc. complete for finished item of work as per SS 20 B (APSS 308) Ordinary Soil Manual Means Up to 3 m depth 100.000 243.20 24320.00 Cum 3.1.1 3 Filling with excavated earth (excluding rock)/ Sand in trenches, sides of foundations and basement with initial lead in layers not exceeding 15 cm thick, consolidating Each deposited layer by watering and ramming including cost and conveyance of water to work site and all operational, incidental, labour charges, hire charges of T and P etc., complete for finished item of work. (APSS NO. 309 and 310) (Excluding cost of sand) by Manual Means 100.000 34.50 3450.00 Cum 3.3.1 4 Cement Concrete 1:4:8 with 40 mm size Crushed granite metal of approved hard quality in foundations or Plinths etc., Complete (But Excluding Cost of Cement) with concrete mixer 8.000 3444.17 27553.36 Cum 4.2 5 Cement Concrete 1:3:6 with 40mm down size (50% of 40 20mm, 30% of 20 10mm and 20% of 10 4.75mm) graded Crushed Granite metal of approved hard quality including machine mixing, vibrating, etc., Complete for finished Item of work as directed for Side Walls of Drains or Basement/ Substructure of the Buildings (Excluding Cost of Cement, Centering and shuttering charges) (CA : 0.90 Cum, FA:0.45Cum) 8.000 3487.27 27898.16 Cum 4.3.1 6 Add Extra for shuttering and centring charges for CC Basement / Sidewalls, Water Tank Walls 40.000 393.10 15724.00 Sqm 4.3.3 7 Cement Concrete 1:2:4 with 20mm down size (65% of 20 10mm and 35% of 10 4.75mm) graded Crushed Granite metal of approved hard quality inclusive of shuttering/centering charges for bed blocks, encasing joists/ rails, holdfasts of doors and windows, etc. Complete (But Excluding Cost of Cement) with concrete mixer (CA : 0.90 Cum, FA:0.45Cum) 5.000 4631.87 23159.35 Cum 4.10.2 8 Labour charges for cutting, bending and binding reinforcement with contractors binding wire, and placing in position as directed by Engineer in charge including all leads, etc., complete 1.500 13984.40 20976.60 Tonne 5.5 Page 1 of 8   Work Code No: Slno RG3/01/R23/5200 SR Item & Description Quantity Rate Amount Unit 9 Reinforced Cement Concrete 1:2:4 with 20mm down size (65% of 20 10mm and 35% of 10 4.75mm) graded crushed granite metal of approved hard quality for precast RCC slabs, purlins, verandah posts, fencing posts etc. including machine mixing of Concrete, necessary shuttering, finishing etc including hoisting/fixing, cost and conveyance of all materials to work site, all labour charges, all operational incidental charges (excluding cost of steel and its fabrication charges and cost of cement) etc., complete for finished item of work, as directed. (CA : 0.90 Cum, FA:0.45Cum) 10.000 6762.77 67627.70 Cum 5.7 10 Flyash Brick masonry with bricks of size 225x100x60mm with 50kg/cm2 Compressive strength in C.M.1:6 for superstructure including scaffolding etc., (But Excluding Cost of Cement) complete. 5.000 6724.31 33621.55 Cum 7.1 11 Binding wall 225x225mm size with brick in cement mortar 1:6 with fly ash bricks of compressive strength 50Kg/cm2 with 20mm thick plastering with cement mortar 1:6, with cornice 100x 100mm ( But Excluding Cost of Cement ) 5.000 612.17 3060.85 Rm 7.14 12 Binding wall 225 x 225mm size with brick in cement mortar 1:6 with fly ash bricks of compressive strength 50Kg/cm2 with 20mm thick plastering with cement mortar 1:6, without cornice (But Excluding Cost of Cement ) 5.000 496.80 2484.00 Rm 7.15 13 Plastering to brick masonry with cement mortar 1:6, 12mm thick including raking out of joints ( But Excluding Cost of Cement ) 200.000 153.38 30676.00 Sqm 10.1 14 Plastering to brick / stone masonry with cement mortar 1:6, 20 mm thick in two coats including raking out of joints for walls only ( But Excluding Cost of Cement ) 200.000 318.59 63718.00 Sqm 10.4 15 Providing gultha in CM 1:6, 20 mm thick and 150 mm wide including necessary scraping of wall and finishing the surface as directed ( But Excluding Cost of Cement ) 30.000 34.43 1032.90 Rm 10.8 16 Roofing/Side sheeting with A.C corrugated sheets 6mm thick including cost and conveyance of AC Sheets, 8mm dia G.I J bolts, GI washers, bitumen washers and labour charges including fixing of wind ties as per the requirement etc., complete (with /without Ridges / Valley gutters) for finished item of work (cost of wind ties and its fabrication charges are not included) 100.000 404.90 40490.00 Sqm 11.1 17 Labour charges for fixing AC sheets for Roofing/Side sheeting including cost of 8mm dia J bolts and nuts, Bitumen washers, 8mm dia plain GI washers including fixing of wind ties as per the requirement etc., (with /without Ridges) complete for finished Item of work (cost of wind ties and its fabrication charges are not included) 100.000 108.80 10880.00 Sqm 11.2 18 100.000 796.90 79690.00 Sqm 11.9 Page 2 of 8   Work Code No: Slno RG3/01/R23/5200 SR Item & Description Quantity Rate Amount Unit Roofing/side sheeting with Pre painted Galvalume Trapezoidal Profile Roofing sheets with 0.50mm thickness, Coating: Alu Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colours fixed with Suitable Bolts, nuts and washers, including fixing of wind ties as per the requirement etc., and including cost and conveyance of all materials etc., complete (with / without Ridges/ valley gutters) for finished Item of work as directed. (cost of wind ties and its fabrication charges are not included) 19 Dismantling G.I sheets, AC Sheets in Sides and Roof including ridging etc., 80.000 71.90 5752.00 Sqm 11.8 20 Providing and fixing Thermocole False ceiling 600mmx 600mm using 19mm thick Thermocole sheet, anodised Aluminium Tee sections of size 24.50mm x 24.0mm x 2.4mm in grid with cross tee of size 24mm x 24.5mm x 2.4mm at every 600mm c/c and anodised aluminium wall angle of size 24mm x 24mm x 2.4mm fixed to periphery of the wall and the above grid is suspended at every 1200mm c/c in both directions using 2.0mm thick GI Wire including cost and conveyance of all materials to site etc., for finished item of work as directed. Holding down clips to be used for fixing Thermocole sheets. 80.000 639.80 51184.00 Sqm 12.1 21 Flooring 40mm thick with CC1:2:4 using 20mm Down size ( 65% of 20 10mm and 35% of 10 4.75mm ) graded crushed granite metal of approved hard quality on existing concrete base, rendering smooth complete. ( But Excluding Cost of Cement ) 40.000 275.91 11036.40 Sqm 14.2 22 Flooring 50 mm thick with CC 1:2:4 using 20mm Down size (65% of 20 10mm and 35% of 10 4.75mm) graded crushed granite metal of approved hard quality on existing concrete base, rendering smooth complete. (But Excluding Cost of Cement ) 60.000 312.51 18750.60 Sqm 14.3 23 Flooring with Non skid Ceramic floor tiles of size 400 x 400 mm and thickness between 7 8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, set over base coat of cement mortar (1:6), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per Sqm and jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost and conveyance of all materials, labour charges etc., complete for finished item of work, (But Excluding Cost of Cement ) 40.000 865.02 34600.80 Sqm 15.1 24 Providing skirting /risers of steps with ceramic wall tiles of size 200 x 300mm / 245mm x 325mm with 6 mm thick 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs and length equal to flooring tiles, set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost and conveyance of all materials, labour charges etc., complete for finished item of work,( But Excluding Cost of Cement ) 10.000 527.62 5276.20 Sqm 15.2 Page 3 of 8   Work Code No: Slno RG3/01/R23/5200 SR Item & Description Quantity Rate Amount Unit 25 Providing Dadooing to walls with ceramic wall tiles of size 200x300mm / 245mm x 325 mm and thickness 6 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost and conveyance of all materials, labour charges etc., complete for finished item of work,( But Excluding Cost of Cement ) 5.000 696.82 3484.10 Sqm 15.3 26 Supply and fixing of Cement bonded Particle BOARD (conforming to IS 14862) door shutter with all round style “U” lipping size 15 x 18 x 15 mm made from 0.8mm thick powder coated cold rolled steel profiles with 16 mm thick Cement bonded Particle BOARD with necessary screws fixed at 1’ 0” interval including cost and conveyance of all materials at site and applying 1 coat of primer, 2 coats of luppum and 2 coats of synthetic enamel paint with following MS powder coated fittings as per approved design for finished item of work SINGLE SHUTTER as per Approved Make a). MS Nickel coated coated 250mm long aldrops 2 nos , b). MS powder coated 250mm long tower bolt with 10mm dia shoot 1 nos, c). 1no. MS powder coated 150mm long grip handle, d). 1nos. M.S. Powder coated Door stopper. 5.000 1817.80 9089.00 Sqm 16.18 27 Supply and fixing of Cement Bonded Particle Board (IS 14862) door shutters using with 16MM thick with all round style “U” lipping size of 20mm x18mm x20mm made from 0.6mm thick galvanized pre painted cold rolled steel profiles with Cement Bonded Particle Board separating two shutter with 30mm x20mm x30mm Stepped lipping including cost and conveyance of all materials at site and applying one coat of primer, 2 coats of luppam and 2 coats of synthetic enamel paint as per approved design for finished item of work BISON PANEL(IS 14276) DOUBLE DOOR SHUTTER with necessary screws fixed at every 1foot (304.8mm) intervals and including the following MS powder coated fittings. etc., complete finished item of work as per Approved Make a). 250 mm long aldrops 2nos. b). 250mm long tower bolt with 10mm dia shoot 2nos c). 2nos 125 mm long grip handle d) 2 Nos. Door Stopper 5.000 2308.10 11540.50 Sqm 16.19 28 Painting to wood work/ Plastered Surfaces with Two coats of synthetic enamel paints of grade II of Approved Make, shade to old works complete for finished item of work. 50.000 115.10 5755.00 Sqm 17.2 29 Painting to Iron work with two coats of synthetic enamel paint of grade II of Approved Make and shade including a base Coat of Red oxide primer paint of grade I of Approved Make making 3 coats To new work all complete for finished item of work. 100.000 170.80 17080.00 Sqm 17.7 30 Painting with two coats of Synthetic enamel paints of grade II paints of Approved Make and Shade to Old Iron work complete for finished item of work. 50.000 103.00 5150.00 Sqm 17.8 31 White washing to Old walls with Surya Cem / Equivalent Cem, two coats complete for finished item of work. 500.000 26.20 13100.00 Sqm 18.2 Page 4 of 8   Work Code No: Slno RG3/01/R23/5200 SR Item & Description Quantity Rate Amount Unit 32 White washing to Old walls with Surya Cem / Equivalent Cem, One coat complete for finished item of work. 500.000 17.70 8850.00 Sqm 18.4 33 Whiting to OLD ceiling with Surya cem / Equivalent Cem, two coats to give an even shade complete for finished item of work. 100.000 28.90 2890.00 Sqm 18.6 34 Whiting to Old ceiling with Surya cem / Equivalent Cem ,One coat complete for finished item of work. 100.000 17.70 1770.00 Sqm 18.7 35 Colour washing to OLD WALLS with Surya Cem / Equivalent Cem adding required colour two coats complete for finished Item of work. 1000.000 28.00 28000.00 Sqm 19.2 36 Oil bound Distempering to Old walls with 2 coats of Approved Make distemper complete for finished Item of work. 250.000 67.40 16850.00 Sqm 20.2 37 Acrylic exterior emulsion Painting to Old walls 2 coats with Grade I i.e., Apex or equivalent paint of Approved Make complete for finished Item of work 100.000 115.00 11500.00 Sqm 20.8 38 Acrylic exterior emulsion Painting to New walls with Grade II i.e., Ace or equivalent paint of Approved Make 2 coats over a base coat of Grade II primer (making 3 coats in all) complete for finished Item of work For External Walls 100.000 167.40 16740.00 Sqm 20.9 39 Acrylic exterior emulsion Painting to Old walls 2 coats with Grade II i.e., Ace or equivalent paint of Approved Make complete for finished Item of work For External Walls 100.000 104.00 10400.00 Sqm 20.10 40 Fabrication of structural steel components like stanchions, built up columns, trestles, beams, trusses, N girders, chequered plate walk way etc., including all leads and lifts at site etc., with companys steel sections but with contractors welding rods, bolts, rivets and all contingencies, power charges, etc., complete as per drawings and instructions of the Engineer in charge. 6.000 18178.40 109070.40 Tonne 25.1 41 Erecting companys steel stanchions, built up columns, trestles, beams, trusses, N girders, chequered plate walk way etc., with contractors tackle, derric, crane etc., complete 6.000 10225.40 61352.40 Tonne 25.2 42 Fabrication of structural steel components like purlins, louvers, sag rods, rafters etc., including all leads and lifts at site etc., with companys steel sections but with contractors welding rods, bolts, rivets and all contingencies, power charges, etc., complete as per drawings and instructions of the Engineer in charge. 3.000 14770.00 44310.00 Tonne 25.3 43 3.000 9089.20 27267.60 Tonne 25.4 Page 5 of 8   Work Code No: Slno RG3/01/R23/5200 SR Item & Description Quantity Rate Amount Unit Erecting companys steel purlins, louvers, sag rods, rafters etc., with contractors tackle, derric, crane etc., complete 44 Labour Charges for Fabrication of steel works like window grills, compound wall grills, Iron Doors, windows, Verandah grils and window guard bars including cost of welding rods, power charges etc., ( Excluding cost of fixing in position) 100.000 34.10 3410.00 Kg 25.5 45 Labour Charges for Fixing of window grills, compound wall grills, Iron Doors, windows, Verandah grils, and window guard bars in position etc., complete. 100.000 5.70 570.00 Kg 25.6 46 Supplying, laying, fixing and commissioning the SWR pipes of Prince / Sudhakar / Kisan / Supreme or any ISI Brand SWR Pipe (as per ISI standards) Type A pipes (PVC / SWR pipe 4Kg / sq.cm ) for rain water and vent pipes of any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice excluding cost of fittings For 110mm dia 3M Double socket pipe 10.000 1055.30 10553.00 Each 28.1.3 47 Supplying, laying, fixing and commissioning the SWR pipes of Prince/Sudhakar/ Kisan/ Supreme or any ISI Brand SWR Pipe (as per ISI standards) Type B Pipes (PVC/SWR pipe 6 Kg/sq.cm) for soil and sullage water of any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice excluding cost of fittings. For 110mm dia 3M Double socket pipe 10.000 1490.40 14904.00 Each 28.2.3 48 Construction of 450mm x 450mm and 450mm depth Inspection Chamber with CC 1:4:8 base of 150mm thick 40 mm Crushed Granite metal and 225 mm thick Brick masonary walls in CM 1:6 with fly ash bricks of size 225 x 100 x 60mm with 50kg/Sq. Cm Compressive strength and plastering with CM 1:4; 12mm thick including rendering the surfaces smooth both inside and outside and channelling to required slope including supply and fixing precast RCC 1:2:4 cover of 50mm thick and 600 X 600mm size with 20mm down size (65% of 20 10mm and 35% of 10 4.75mm) graded Crushed Granite metal, including earthwork excavation to the required depth etc; complete for finished item of work (but excluding cost of cement steel and its fabrication charges.) 5.000 3112.76 15563.80 Each 28.36.1 49 Extra depth of 450mm x 450mm Inspection Chamber beyond 450mm depth (Excluding cost of cement) Extra for every 0.100m (100mm) depth 15.000 470.64 7059.60 Each 28.36.2 50 Construction of 900mm dia and 450mm depth circular manhole with CC 1:4:8 base of 150mm thick with 40 mm Crushed Granite metal, 225mm thick Brick masonry walls in C.M 1:6 with Flyash bricks of size 225X100x60mm and having compressive strength of 50 kg/sqcm, plastering with CM 1:4,12mm thick including rendering the surfaces smooth both inside and outside and benching with 100mm thick CC 1:2:4 with 20mm down size (65% of 20 10mm and 35% of 10 4.75mm) graded Crushed Granite metal and channelling to required slope including supply and fixing precast RCC 1:2:4 cover of 50mm thick and 600mm dia using 20mm down size (65% of 20 10mm and 35% of 10 4.75mm) graded Crushed Granite metal, including earth work excavation to the required depth etc. complete for finished item of work (but excluding cost of cement, steel and its fabrication charges.) 5.000 4612.75 23063.75 Each 28.35.1 Page 6 of 8   Work Code No: Slno RG3/01/R23/5200 SR Item & Description Quantity Rate Amount Unit 51 Extra depth of Circular Man Hole of Size 900mm dia( Excluding Rock cutting) beyond 450mm depth (Excluding cost of cement) Extra for every 0.100m(100mm) depth 25.000 691.97 17299.25 Each 28.35.2 52 Supplying and fixing 580 x 440mm Orissa pan white glazed W.C first quality ISI marked conforming to IS 2556 part 3 2004 with P or S trap 5.000 2399.80 11999.00 Each 28.47.1 53 Supplying and fixing wash down European water closet of first quality conforming to IS 2556 Part 2 2004 of white glazed with P trap. Plastic seat and lid is to be paid extra. 10.000 2118.90 21189.00 Each 28.49.1 54 Supply and fixing of PVC low level Cistern with internal components and short bend, 10 Ltrs capacity Dual flush 10.000 2217.60 22176.00 Each 28.51.2 55 Supplying and fixing 15 mm Nominal Bore G.I pipe Medium Grade properties and weight as per IS 1239 ISI mark with G.I fittings including the cost of pipe and its fittings like sockets, elbows, bends, tees, etc., and labour charges complete 20.000 237.10 4742.00 Rm 28.6.1 56 Supplying and Fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS: 2556 Part 4:1972 with waste fittings like 32mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963 1979 and fitted with 15mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400grams Seiko/Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550x400mm Single C.P. Pillar Cock 4.000 2533.80 10135.20 Each 28.57.1 57 Conveyance charges of Steel including loading, unloading and stacking charges for 2 KM lead. 10.500 284.42 2986.41 Tonne 34.8.2 58 Conveyance charges of CEMENT including loading, unloading and stacking charges for 5 KM lead. 24.942 276.20 6888.98 Tonne 34.9.5 59 Conveyance charges of CEMENT including loading, unloading and stacking charges for Beyond 5KM and upto 30KM(Rate/KM) lead. 199.536 10.10 2015.31 KMMT 34.9.6 60 Reinforced Cement Concrete 1 : 1.5 : 3 with 20mm down size (65% of 20 10mm and 35% of 10 4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum) for Column footings / Raft 12.000 6986.27 83835.24 Cum 5.1.1 61 15.000 6433.47 96502.05 Cum 5.1.10 Page 7 of 8   Work Code No: Slno RG3/01/R23/5200 SR Item & Description Quantity Rate Amount Unit Reinforced Cement Concrete 1 : 1.5 : 3 with 20mm down size (65% of 20 10mm and 35% of 10 4.75mm) graded Crushed Granite metal from approved quarry including cost and conveyance of all materials like sand, coarse aggregate, water etc., to site and including machine mixing and vibrating with mechanical vibrators, finishing, and centering/shuttering charges, etc, (but excluding cost of steel reinforcement and its fabrication charges and Cost of Cement) (CA : 0.90 Cum, FA:0.45Cum) For precast RCC Sleepers but Excluding hoisting / fixing charges
Contract Date: Ref. Documents Contract Value : 9.22 Lakh
Government Departments No of Bidders 1
50.
Agriculture #10988522 Technical Bid
Tender for Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In, All Kinds Of Soil , Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Providing And Laying In Position Specified Grade Of Cement Concrete For All Reinforced Cement Concrete Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.M20 Grade Nominal Mix / Design Mix , Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :Columns, Pillars, Posts And Struts Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. (Original Producers Who Manufacture Billet Directly From Iron Ores And Roll The Bilets To Produce Steel Conforming To Is:1786)Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) , Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Brick Work With Clay Flyash F.P.S. Brick (Is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) , Add Extra For Square Or Rectangular Pillars In Superstructre Brick Work Up To Five Storey Upto 45 Cm Length And Two Corners Are Free , Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In. Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) , Supplying And Fixing In Walls Machine Cut And Polished Stone Shelves, Tands And In Cm 1:3 With Machine Cut Edges : Kota Stone Minimum 30Mm Thick. , P & F 1St Qualityheavy Duty Vitrified Polished Digital Tiles On Floor, Skirting And Steps Etc.In Different Sizes (Thickness Minimum 10Mm) With Water Absortion Less Than Or Equal 0.08% And Conforming To Is 15622 Of Approved Make In All Colour And Shade, Laid With 20 Mm Thick Cm 1: 4 Including Grounting The Joints With White Cement And Matching Pigment Etc Complete.Size 600Mm X 600Mm , Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12Mm (Av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1White Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) Above 3601 Cm2 Slabs , Extra For Providing Edge Moulding To 15-18Mm Thick Marble/ Granite/Kota Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Granite/Kota Stone Work Full Edge Moulding , Providing And Fixing 1St Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200Mm X 300Mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Excluding The Cost Of Cement Plaster On Walls And Pillar). , Providing And Fixing 1St Quality Mat Finished Ceremic Tile Size 300X300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (Including The Cost Of Cement Mortar Bed 1:4). , Extra For Using Size Above 200X300mm In Glazed Tiles And For Using 400Mm X 400Mm Mat Finished Tiles In Place Of 300Mm X 300Mm Size. Wall Tiles , Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal Dehyderesin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure A : 30 Mm Thick . Commercial Veneer Both Side , Extra For Providing External Lipping With 2Nd Class Teak Wood Battens 6 Mm Minimum Depth On All Edges Of Shutters (Over All Area Of Door Shutter To Be Measured) Over Item No. 8.13. , Providing And Fixing Pressed Steel Door Frames Confirming To Is 4351 Manufactured From Commercial Mild Steel Sheet Of 1.25 Mm Thickness Including Hinges Jamb, Lock Jamb, Bead And If Required Angle Threshold Of Mild Steel Angle Of Section 50X25mm, Or Base Ties Of 1.25Mm Pressed Mild Steel Welded Or Rigidly Fixed Together By Mechanical Means, Adjustable Lugs With Split End Tail To Each Jamb Including Steel Butt Hinges 2.5Mm Thick With Mortar Guards, Lock Strike-Plate And Shock Absorbers As Specified And Applying A Coat Of Approved Steel Primer After Pre-Treatment Of The Surface Including Filling With cement concrete 1:2:4(M15 Grade) Complete As Directed By Engineer-In-Chargeprofile C : , Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). , Providing And Fixing M.S. Sheet 1Mm Thick Single Leaf Door Shutter In Angle Iron Frame 35X35x5mm Suitabilly Diagonally Braced With 25X3mm Flat Iron Above And Below Lock Rail Of Size 50X5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint , Providing And Fixing Steel Glazed Window Frame Made Out Of 80X40 Mm Hollow Sheet Section Of 16 Gauge Thickness, Joint Mitred Welded And Grinded Including Hold Fast Of Steel Lugs 13Mm X 3Mm And 15 Cm Long Embedded In C C Block 15 X 10 X 10 Cm Of 1:3:6 Nominal Concrete And Including Fixing Of Pivoted Hinges Of Superior Quality, Window Shutters Made Out Of 50 X 25.0 Mm Hollow Steel Section 15 Mm Paitam Of 18 Gauge Thickness, Joint Mitred And Grinded Including 10Mm X 10Mm Square Bars Welded To Frame For Paitam Fixing Float Glass 4Mm Thick Panes With Glazing Clips And Metal Sash Putty And Fixing Of Shutters Frames Peg Stay, U Shape Handle 100 Mm Long, Tower Bolts 100 Mm Long Of Steel Powder Coated Superior Quality Including Fixing And Jointing With Frame Hinges Priming Coat With Steel Primer Complete In All Respect As Per Direction Of Engineer-In -Charge , (A) Window Openable. , (B) Window Fixed. , Extra For Additional Shutter In Pipe Section Windows With Wire Gauge 14 Mesh X 24 Gauge , Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. , Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Dark Shade Using Ordinary Cement. , Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge , 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :12Mm Thick . , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 20Mm Thick . , Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete New Plastered Surface (Three Or More Coats) , Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: Two Or More Coats On New Work Including Prepartion Of Base With Primer, Putty, Lippy Etc Complete In All Respect. , Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Fixed Portion Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Aluminum Work For Doors ,Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips ,Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top ,Bottom And Sides With Required Pvc/Neoprene Felt Etc. Aluminium Section Shall Be Smooth ,Rust Free, Straight ,Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing /Paneling , C.P. Brass/ Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc.,All Complete As Per Architectural Drawings And The Directions Of Engineer- In - Charge .(Glazing And Paneling To Be Paid For Separately).For Shutters Builtup Standard Tubular Sections Of Openable Doors ,Windows & Ventilators Including Providing & Fixing Hinges / Rollers Etc. And Making Provision For Fixing Of Fittings Wherever Required (Lockes Shall Be Paid For Separately). Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing Double Action Hydraulic Floor Spring Of Approved Brand And Manufacture Is : 6315 Marked, For Doors Including Cost Of Cutting Floors As Required, Embedding In Floors And Cover Plates With Brass Pivot And Single Piece M.S. With Stainless Steel Cover Plate , Providing And Fixing Glazing In Aluminium Door, Window ,Ventilator Shutters And Partitions Etc. With Pvs / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge.(Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item.)With Float Glass Panes Of 5.0 Mm Thickness ( Weight Not Less Than 13.50 Kg/Sqm) , Providing And Fixing Expanded Grill Made Of Aluminum As Per Design And Drawing Having Members Section Of Size 7.5Mm X 6.0Mm And Opening Of Size 102Mm X 99Mm To Aluminum Window/Vent With Required Screws, Y And H Aluminium Sec (As Per Drawing) At The Ends And Middle Joints Respectively Complete In All Respect As Per Direction Of Engineer In Charge.Powder Coating Aluminum ( Minimum Thickness Of Powder Coating 50 Micron) , Providing And Fixing 12 Mm Thick Prelaminated Three Layer Medium Density (Exterior Grade ) Particle Board Grade I, Type Ii Conforming To Is : 12823 Bonded Formaldehyde Synthetic Resin ,Of Approved Brand And Manufacture In Paneling Fixed In Aluminium Doors ,Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Direction Of Engineer-In-Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Curtain Rods Of 1.25 Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs, Etc., Wherever Necessary Complete: 20 Mm , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. , Carriage Of Earth Incloding Loading ,Unloading Without Stacking With Lea Of 5Km , Making Grooves As Per Design In Plaster 10Mm To 20Mm Wide. , Extra For Plastering Done On Moulding Cornices Or Architraves Including Neat Finish To Line And Level: In Two Coats , Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated ‘J Or ‘L Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified.5.0Mm Thick (Wt. 8.4 Kg./Mtr. Sq.) , Providing Gola 75X75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10Mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : , Crazy Marble Stone Flooring 20Mm Thick Marble Stone With Black Or Of Specified Colour Topping Including Filling The Gaps With Cement Marble Chips Mix In Proportion Of 4 : 7 (4Cement : 7 White Black Or White Or Black Marble Chips) Size From 1Mm To 4Mm By Volume And Under Layer Of 25Mm Thick Cement Concrete [1:2:4, Graded Stone Aggregate 12.5Mm Nominal Size] Rubbing And Polishing And Cement Slurry Etc. Complete : In Ordinary Cement. , Extra In Marble/Other Flooring Work For Upto 50 Mm Wide Strip Of Green/White/ Jaisalmer Stone In Flooring Work As Per Direction Of Engineer In Charge , Providing & Fixing Precast Cement Concrete Coping 1 : 2 : 4 Mix 50Mm Thick Complete As Per Specification : , Renewing Glass Panes,With Putty And Nails Wherever Necessary Float Glass Panes Of Thickness 5 Mm , Filling Of Sunk Portion Of Roof With Earthen Pots Of Required Height Including Filling Voids With 1:3:6 Light Concrete, Using Brick Bats Complete Levelling And Dressing The Surface By 50Mm Thick Cement Concrete 1:2:4 As Per Specification. , Supply And Fixing In Cement Mortar Welded Hand Railing Made Out Of Ms Round Or Square Bars, Flats Etc. For Staircase Or Verandah As Per Design Complete In All Respect (Wooden Or Pvc Hand Railing To Be Paid Extra) With Priming Coat Of Red Oxide. , Extra For Providing D Type Pipe Head As Top Of Hand Railing , Providing And Fixing Almirah Lock (50 To 70 Mm Size )Of Approved Make Without Pair Of Handles For Door With Necessary Screws Etc Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). Grade 304 , Lettering With Black Japan Paint Of Approved Brand And Manufacture. , Construction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Tractor Mount Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Morth Specification Clause 401..For Grading Iii Material , Construction Of Embankment With Approved Material Obtained From Borrow Pits With A Lift Upto 1.5 M, Transporting To Site, Spreading, Grading To Required Slope And Compacting To Meet Requirement Of Tables 300-1 And 300-2 With A Lead Upto 5.00Km As Per Morth Specification Clause 305.3 , Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer (Pug Mill), Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base/Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400-12 & 400-13 And Morth Specification Clause 406.By Mechanical Means With All Lead , Providing And Laying Of Interlocking M-30 Grade Concrete Block Pavements Having Thickness 80 Mm As Per Drawings And As Per Is 15658:2006.And All Materials Shall Conform To Morth Specification Clause 602.With M-30 Grade 0.30 Mtr X 0.30 Mtr X 0.15 Mtr Edge Blockscategory B : Dentated Only Two Side Like I,Z,T Shape As Per Irc:Sp:63-2004 , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Dia. Nominal Bore. , Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 200Mm Dia. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. 200Mm Normianl Bore , Supply Of Erw M.S. Black Casing Pipe Isi Marked Is:4270/ 1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 200Mm Normianl Bore , Development Of Tube Well As Per Is Specification Using Suitable Compressor To Give Sand Free Water For Required Yield Of The Gravel Packed Tube Well. , S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size:200Mm Dia. , S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. , P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440mm. , P & F European Type White Glazed Vitreous China 1St Quality Double Syphonic W.C (Is :2556 Mark) With P Or S Trap Including Cutting And Making Good The Wall And Floor , P & F Water Closet Seat Covers With Brass Hinges Complete :Solid Pvc (Is 2548 Marked) Grade-I Black For Ewc. , P & F Low Level Flushing Cistern Of 10 Litres Capacity (Is : 2556 Mark) Of Approved Make With Complete Fittings C.I. Brackets Duly Painted, Brass Ball Cock With Ball (Is: 1703 Mark) Complete Including Cutting And Making Good The Wall: Pvc With Pvc Bend And Superior Internal Fittings As Per Is : 7231 . , P & F Flush Pipe Of Approved Make With Complete Fittings For High Level Flushing Cistern: Pvc Exposed (Heavy) 32Mm. , P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall : , Size 580 Mm X 450 Mm , Size 630 Mm X 500 Mm Dia For Counter Top , P & F Bevelled Edge Mirror/Mirror With Teak Wood Lipping Around Of Special Glass Of Approved Make As Per Direction Of Engineer-In-Charge Complete With 6Mm Thick Commercial Ply Base Fixed To Wooden Screws & Washers. Size 600 X 450Mm X 4 Mm Thick , P & F Towel Rail Or Ring Of Approved Quality/Make: , C.P. Brass Towel Rail Elbow Type With Concealed Screws Size 450Mm (Heavy Duty). , P & F Grating Of Approved Quality/Make: , Stainless Steel Sheet Size 125Mm Dia. , P & F Liquid Soap Container With Brackets Complete Of Approved Make: , P & F Jet Spray For Water Closet With C.P. Copper Tube Flange Of Approved Make. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Concealed Work Including Cutting Chases And Making Good The Walls Etc.,) , 20 Mm Nominal Outer Dia Pipes , 25 Mm Nominal Outer Dia Pipes , Making Connection Of G.I. Distribution Branch With G.I. Main Including All Fitting. , Upto 25Mm Dia , P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: , C.P. Brass Bib Cock,15Mm Nominal Bore. , C.P. Brass Bib Cock Long Body, 15Mm Nominal Bore Weight Not Less Than 690 Gm , P & F Ball Cock (Is :1703 Mark) With Rod & P.V.C. Ball Complete : Brass Wt. Not Less Than 300 Gm,15Mm. , P & F Inlet Connection (Angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.P. Inlet Connection 15Mm.Brass (Is : 8931 Marked) , P & F 15 Mm. Dia Connection Pipe Of Approved Quality/Make : Pvc Pipe With C.P. Brass Nuts Upto Length 450Mm. , P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make : , Gun-Metal 15Mm Nominal Bore. , Gun-Metal 25Mm Nominal Bore. , P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 1000 Litres Capacity , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia , P & F S.W. Master Trap (Inter-Cepting) A Grade (I.S.: 651 Marked) Of Approved Quality/Make 150Mm Dia , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia , P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: 110Mm Dia , Coupler (Socket) , Plain Tee , Bend 45 , Vent Cowel , Pipe Clip , Multi Floor Trap , Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade cement concrete Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead. Depth Up To 0.5 M , Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick cement concrete 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade cement concrete Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr. -Do- Size 600 X 450Mm Depth Upto 0.5 M Cement Cover With Frame. , Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick cement concrete Bed Of 1:5:10, M-15 Grade cement concrete Floor & Reinforced Cement Concrete Slab Covering With M15 Grade cement concrete Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140x150 Cm.(For 50 Users) With 115 Mm Thick Reinforced Cement Concrete (M-20) Slab With Tor Steel Reinforcement 10Mm Φ @15 Cm C/C Bothways Including Shuttering Complete In All Respect. , Construction Of Recharge Shaft In Filter Pit Including Earth Work Excavation , Lifting Excavted Earth With All Lift And 50 M Lead And Centering & Shuttering Evenever Required.Diameter 900 Mm , Supply & Fixing Pre-Cast Reinforced Cement Concrete Rinngs At The Mouth Of Recharge Shaft Of M20 Mix With 40 Mm Thicknessdiameter 900 Mm , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils , Add Extra For Foundation/Trenches/Drains For Every Additional Lift Of 1.5 Mtr. Or Part Thereof In All Kinds Of Soil , Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size). , Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In:Cement Mortar 1:6 ( 1-Cement : 6-Sand). , Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish :20Mm Thick . , Finishing With Neat Cement (Punning). , Providing And Laying In Position Specified Grade Of Cement Concrete For Reinforced Cement Concrete Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix. , Add Extra For Providing Richer Mixes Respectively At All Floor Levels, Providing M-25 Grade Concrete By Using Min 410 Kg Of Cement Per Cum Instead Of M-20 Grade Design Mix. , Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. , Providing And Fabricating Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code). , Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 75Mm Thick With 20Mm Thick Nominal Size Aggregate. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting (Height Upto 10 M) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , Inside Size 600X450mm Upto Depth Of 0.5M & 38Kg Ci Cover With Frame , 250Mm Dia Internal. , P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii(4 Kg. /Cm.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant, 160Mm Dia. , 250Mm Dia S.W. Pipe. , P & F 60 Cm. Wide M.S. Ladder In Open Well Made Of Flat Iron 32X5mm And 10Mm Dia Bars @ 200Mm C/C With Angle Iron Hold Fasts At Suitable Interval Complete As Per Drawing. , Construction Of Tube-Well From Ground Levels And Upto 100 Meter Depth And Above To Accommodate Housing And Assembly Pipe Of Following Sizes In All Types Of Alluvium Strata By Percussion/ Rotary Drilling Method And With Gravel As Per Is:4097-1967 And Packing As Per Is:2800 (Part I -& Ii) 1979 As Amended Upto Date (The Work Includes The Cost Of Gravel & Its Primary Packing And Packing During Development, Lowering Of Housing & Strainer Assembly Pipes, With Supply And Wrapping Of Coir-Rope, Wherever Necessary, For Arresting Fine Sand Particles. The Work Will Not Include Cost Of Housing Pipe And Strainer Pipe Assembly And Development Work, But Work Would Be Completed After Obtaining Sand Free Water).200Mm Nominal Bore , P & F G.I. Pipes (Internal Work) With G.I. Fittings (Is:1239-1992 Mark) & M.S. Clamps Including Cutting And Making Good The Walls And Floors : Exposed On Wall, 15 Mm Dia Nominal Bore. B - Class. , Supply Of Strainer Pipes Made Of Erw M.S. Black Pipe Isi Mark Of Following Sizes At The Site Of Work Including Required Size Of Slotting As Per Is:8110-1985. , Size 9 To 12 Mm , Size 3 To 5 Mm , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr.) , Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modular Box Of 1.2 Mm Thick With Earth Terminal,2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector ,Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Medium Point (Up To 6 Mtr.) , Long Point (Up To 10 Mtr..) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & Its Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , On Board , Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , S&F Following Sizes (Dia.) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along With Isi Marked (Is:3419-1988) Accessories As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Mm , 32 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 2X 1.5 Sq.Mm , 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. , 4 X 10.0 Sq.Mm , 4 X 16.0 Sq.Mm , Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Providing & Fixing Of Wiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess/ Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1/2 Module , Providing & Fixing Of Following Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1-2 Module , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Single Pole Mcb (With B/C Curve Tripping Characteristics) , 6 A To 32 A Rating , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box , 6 Way , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For Mcb / Rccb And Sp / Tp Mcb As Outgoing ,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door (For Double Door Db Only ) Complete With Insulated 100 A Rating Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Double Door Ik-09 & Ip-43 With Metal End Box , 6 Way(8+18) , Providing & Fixing Of 240/415 V Isolator Isi Marked Is:13947-Iii/Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , Four Pole Isolator , 80 A/ 100 A Rating , Triple Pole Isolator , 63A Rating , Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 25 Amp. 2 Module Motor Starter With On / Off Push Button , Blanking Plate , Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 5 Step Fan Regulator 2 Module 360 Dgree Rotating , Providing & Fixing Of Modular Type Switch/ Bell Push Duly Isi Marked (Is :3854) With Cm/L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating ,Minimum Width Of Switch Toggle( Push Part ) Should Not Less Then 20Mm, Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 10 A Bell Push , Providing & Fixing Of Ding Dong/Musical Chime Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply Installation Testing and Commissioning of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Improvement =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , 3 Pole Mccb With Thermal Magnetic Release , Up To 100 annual periodical maintenance , 25 Ka, Adjustable O/L & Adjustable S/C Setting, , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached . , 35.0 Sq. Mm , 3.5 Core , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Supplying And Making End Termination With Heavy Aluminium Lugs ( Pin / Ring Type ) Confirming To Is 8309 -1993 & Is 8337-1976 Duly Crimped With Crimping Tool, Pvc Tape Etc Of Following Size.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 35.0 Sq.Mm , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 50 Mm , Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: , All Kind Of Soils , Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached. , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor ,Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 300 Mm Sweep , P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Reqd. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Up To 380 Mm Size , Providing & Fixing Of Energy Efficient Direct Fit (Retrofit) Polycarbonate/ Glass Housing Smd Mid Power Led Tube Rod (With Integral Driver & Alumn. Heat Sink ), On Existing Fixture. System Lumen Efficacy ≥ 100 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv ,Thd 20% ,P.F.≥0.95,Cri 80 , Life Time Of Minimum 35000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80)Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1200Mm , Min. Lumens Output 2000 Lm Led Tube Rod With Polycarbonate Housing , Providing & Fixing Of Ip20, 2X2 Led Surface/ Recessed Mounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal/External Surge Protection Bis Certified Isolated Driver Having Efficiency 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of ≥ 120 Lm/Watt ,Thd 10 % , P.F.≥0.95,Cri 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Moutning , Minimum Lumen Output 3600 Lm , Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency 85% . System Lumen Efficacy Of ≥ 110 Lm / Watt, Thd 10 % , Pf.≥0.95, Cri 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. , Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Surface Mounting (With Extruded Alumn. Housing ) , Minimum Lumen Output 1300 Lm , Minimum Lumen Output 1950 Lm , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity 95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached. , 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 32 Mm Dia. , Supply Installation Testing and Commissioning of Mnre Approved & Confirming To Is:12933 P-1,2,3 & 5 Flat Plate Collector Type Solar Hot Water System Having Collector With Zincalum Sheet Outer Body , Glass - Line / Titanium Enamel Coated Inner Tank With Metal Rust Proof Puf Insulated Body Including Electrical Back Up, Thermostat, Powder Coated / Hot Dipped Galvanized Ms Stand For Collector & Tank Etc. As Required. Of Following Capacity Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 250 Litre/ Day , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 4 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 1.5 Tr Iseer Not Less Then 3.8 , Supply Installation Testing and Commissioning of Monoblock Motor Pump Set Isi Marked (Is:9079-2002) With Tefc Motor, Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011. With Stainless Steel Impellor, Stainless Steel Shaft, Mechanical Seal, Single/Three Phase ( 240 - 440 V ) Permanent Split Capacitor Type (Psc), Fitted With Thermal Overload Protection, Including Cost Of Hardware Etc On Existing Platform Complete. Pump Shall Have Following Hp Rating, Phase, Head, Minimum Discharge Respectively Complete In All Respect. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , 2.0 Hp, 3-Ø, (6-27)Mtr, (425-100) Lpm , Supply Installation Testing and Commissioning of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached . , For Single Phase Submersible / Monoblock Pump , 2.0 Hp To 3.0 Hp (Dol Starter)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
TenderDetail