View Bid Results For Pickling Tank Tenders

We found 48 Bid Results related to pickling tank tenders. You can find Contractor details who won pickling tank tenders along with contract details in Bid awards announcements section.

Filters
Stage
25
13
10
Tender Publishing Platform
15
33
State / UT
14
21
6
5
4
2
2
1
1
1
1
1
1
1
1
Contract Value
25
14
5
4
Publish Date
0
0
0
0
0
Sector
11
10
9
8
5
5
4
3
1
1
1
1
Ownership
5
17
10
9
8
4
Within keyword
Active filters:
Showing 1–1 of 48 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 5.31 Lakh
Boards / Undertakings / PSU No of Bidders 2
2.
Housing Urban and Rular Development #11175999 Technical Bid
Tender For Additional Work In Adj No 2 Court Distt. Baran- 1 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 25 Mm X 12 Mm 3 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 5 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 6 Providing & Fixing Of Modular Type Lockable Feature Socket Duly Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 7 25 Amp. 2 Module Socket 8 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (Is 11037:1984 ) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 9 5 Step Fan Regulator 2 Module 360 Dgree Rotating 10 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 11 Led Skirting /Foot Light 2 Module 12 Modular Mcb 6 A To 32 A Sp 13 Providing & Fixing Of 1200 Mm Sweep Bldc Technology Power Saving Ceiling Fan Which Can Withstand On Votage Fluctuations From 140 Volts To 240 Volts ,Power Factor Not Less Then 0.9 , Service Value (Cmm/W) Minimun 6.85 , Air Delivery Minimun 220 Cmm, Speed Minimum 330 Rpm ( Tolerance As Per Is:374 2019 ) Thd Less Then 10% And Complete With Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Up To 80 Cm , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 14 Without Remote 15 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 16 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 17 Rewinding Of Single Phase Motor Of 1400 Rpm Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 18 0.25 H.P. To 0.50 H.P. 19 Rewinding Of Single Phase/3Phase Submersible Motor Including All Necessary Material And Of The Same Characteristics As Original With Required Size Of Super Enamelled Wire E Class Insulation Material And Testing Etc. As Required. Replacement Of Material Or Components Shall Be Use As Per Guidelines Of Oem Of Original Product. All The Scrap Material Should Be Retained By The Contractor. 20 0.5 H.P. To 1.0 H.P. 21 Sitc Of Contactor Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 22 For Single Phase Submersible / Monoblock Pump 23 0.5 Hp To 1.5 Hp (Dol Starter) 24 For Three Phase Submersible / Mono Block Pump 25 Upto 3.0 Hp ( Dol Starter ) 26 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 27 2.5 Sq.Mm 3 Core Flat / Round 28 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have ItS Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 29 6.0 Sq. Mm 30 4 Core 31 50.0 Sq. Mm 32 3.5 Core 33 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 34 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 35 50 Mm 36 90 Mm 37 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 38 Single Pole Mcb (With B/C Curve Tripping Characteristics) 39 6 A To 32 A Rating 40 Four Pole Mcb (With B/C Curve Tripping Characteristics) 41 40 A Rating 42 Supply , Installation, Testing And Comissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 43 1.5 Tr Iseer Not Less Then 3.8 44 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 45 Un Armoured 46 4 Core X 2.5 Sq.Mm 47 Supply, Installation, Testing And Comissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 48 12.7 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 49 6.4 Mm O.D., Wall Thinkness ≥ 0.8Mm (Insulation – 13 Mm Thick) 50 Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 51 20 Mm 52 Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia 53 100 Mm Dia Per Running Inch Length 54 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 55 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp /20 Amp Industrial Plug Top Making Connection Etc Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 56 3 Kva 57 Providing And Fixing Of Ip 65 Protected Polycarbonate / Polysterene Fuse Box Moulded With Inside Knock Outs Of Following Size With Hinged Cover, Transparent Window, Pu Gasket, Locking Arrangement, Duly Holded With 2 Nos. Pole Clamps Of 20 Mm X 3 Mm Flat With Nut And Bolts, The Box Shall Be Provided With Din Rail, 4 / 8 Way 10.0 / 16.0 Sq.Mm Heavy Duty Connector, Earth Terminal, Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 58 125 Mm X 200 Mm X 122 Mm 59 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi/Tia/Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected By Pvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack & Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 60 Supply And Installation Of Unsheilded/360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6/6A Application Complying To Latest Ammendments, According. To Cat. 6/6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6/6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6/6A Unshielded/Shielded Jack Should Be Suitable To Terminate 4 Pair, 23/24 Awg Solid/Stranded Wire Diameters, Using 100 Ohm Unshielded/Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless/Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi/Tia/Eia 568 C.2 Standard. Jack Should Be Rj11,Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb/S Atm,Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip) Specifications In Existing Modular/Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 61 Cat 6, Un-Sheilded Information Outlet 62 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single/Dual Or Quad Aperture , Material Should Be Pc+Abs Body, Suitable For Rj45 Unshielded/Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 63 Single Aperture 64 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6/6A /Class E/Ea Patch Cords Should Be Constructed Of Minimum 23/24 Awg, Stranded Bare Copper Cable With Frpvc/Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi/Tia/Eia 568-C.2 Suitable For Cat 6/6A Application Complying To Latest Ammendments Category 6/6A Standards, According. To Tia568C.2, Iso/Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb/S Atm, Token Ring 4/16, Digital Video And Broadband/Baseband Analog Video, Voice Over Internet Protocal (Voip).All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 65 Cat 6, U/Utp (Unscreened/Un-Sheilded Twisted Pair) Patch Cord 66 0.50 Mtr 67 Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 68 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 69 8 Swg G.I. ( Hot Dipped ) Wire 70 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- 71 (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 72 (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 73 [C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) 74 (D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 75 (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ (No Wire Splitting Or Tee Connections) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 76 (F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 77 (G) Tests: The Insulation Resistance (With 1000 V Megger) And High Voltage Power Frequency Test (By Applying A Voltage Of 2.5Kv For One Minute) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 78 (H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 79 Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 80 Red/Yellow/Green Colour 81 Blue / White Colour 82 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 83 Led Street Light Fixture With Minimum Lumen Output 8700 Lm 84 P/Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 85 1.5 Sq.Mm 3 Core Flat / Round 86 Supply, Installation, Testing And Commissioning Of Bis Compliance Professional Series Diagonal Screen Size 43\ Led With Resolution 3,840 X 2,160 (4K Uhd) Along With Static (Panel) Contrast Ratio (1300:1) Or Better With Viewing Angle Of 178/178 Degree With Response Time Of 8Ms Along With Hdmi In 2.0 - 2 Nos., Usb 2.0 - 2 Nos., Rs 232- 1 Nos., Rj 45- 1 Nos. With Built In Speaker(10W + 10W), With High Speed Processor And Android Or Other Reputed Operating System Along With 4 Gb Ram Along With All Audio And Video Decoder, Stand-By / Sleep / Off Mode Power 0.5 Watt. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 87 Supply, Installation, Testing & Commissioning Of 1 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 3 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. 88 Supply, Installation, Testing & Commissioning Of 2 Kva 1 Phase Input, With Igbt Based Rectifier True Online Double Conversion Robust Design Wide Input Voltage Range: 160-300Vac @ 100% Load (Linearly Derating To 50% Load @ 100Vac Input). Generator Compatible With Wide Input Voltage Window Double Conversion Efficiency >91% & Eco Mode Efficiency Up To 98% 100% Load @ 0~40C Operating Temp. Active Input Power Factor Correction 0.99 O/P Power Factor 0.9 Inbuilt Ovcd (Over Voltage Cut-Off Device) Fully Conform Coated Pcba Adaptable To Harsh Environment Offer Terminal Blocker On 2K/3K Rating To Connect To Big Capacity Equipment Digital Charger Technology Provide 02-10 A Charging Current Easy Understanding Lcd For Convenient Installation Setup With Minimum 60 Minute Battery Back Up (26Ah X 6 Nos Of Smf Batteries Branded And Recommended By Ups Oem, Battery Stand And Interlink Fr Pvc Copper Cable Of Appropriate Size And Lugs), With Required Cabling For Incoming & Outgoing Connection. Ups Should Be Nabl Certified With Ce, Rohs & Bis Compliance. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/Work, Refer Annexure \A\ Attached With This Bsr. Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
3.
Public Administrative Department #10809106 Price Bid
Tender For Electric Work In Municipal Area Sultanpur- 1 Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR Poles with Octagonal Cross Section 9 Mtr. 2 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .Single arm overhang 3 Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. 4 LED Street Light fixture with Minimum lumen output 3700 lm 5 LED Street Light fixture with Minimum lumen output 5600 lm 6 LED Street Light fixture with Minimum lumen output 8700 lm 7 LED Street Light fixture with Minimum lumen output 15000 lm 8 Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . High Power LED Flood Light Minimum lumen output 25000 lm 9 Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discoms standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 75mm x 90mm 10 Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 11 Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discoms specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR LT cross arm 600 mm long with clamp 12 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq.mm 13 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 14 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 6 A to 32 A rating 15 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 50/63 A rating 16 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 80 Amp 17 SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSRup to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 18 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approve One day & week reserve (digital type )d by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 19 Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 8.0 Mtr long PCC pole of 200 Kg Working Load 20 Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discoms standard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 100 mm x 70 mm 21 Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3 X 25 sq. mm. + 1X25 sq. mm. (insulated) 22 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 2 core 23 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4 core 24 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 3.5core 25 P & F of IP 55 protected light controlled switch based oninfrared sensing and daylight with built in over loadprotection, timer to switch OFF at preselected time.Switch shall have 7 day power backup withouthampering of preset time and over ride facility formaintenance purpose Suitable for 15 kw load (three phase) includingcontactor, MCB, cable glands, terminal block andlocking arrangement 26 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 mm Dia. 27 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 40 mm Dia. 28 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 6 SWG G.I. ( Hot Dipped ) Wire 29 Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 30 Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM. 31 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 32 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR B class 50mm dia 33 Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer Cement Concrete Grade M-15 and above and PCC blocks 34 Providing & Fixing of ISO certified company made bolted type/ Din type HBC (High breaking capacity) fuse links of 80 KA breaking capacity,as per PWD specification for electrical Works conforming to IS:13703 in the existing fuse base, fuse switch unit etc. of the following type and rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 63 A to 160 A Size 00 35 Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 6.0 sq.mm 36 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or teeconnections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 37 LINE MAN/WIRE MAN Annual Rate Contract of regular opration and maintence and Changing faulty spare parts, sheets, Wire and Door Switch of all existing pannel complete for 12 month (30 PENNEL) 38 Annual Rate Contract of regular opration and maintence of all type LED street lights fixure with all wattage (20,40,70,130,200)/ HIGH MAST with Complate materials, Drivers, Glass, Chip, Wire, etc Complate Including Line Maintence For 12 Month Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 4
4.
Health and Family Welfare #10551414 Price Bid
Tender For Electrification Work In Phc Building At Palasani District Jodhpur - Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
5.
Health and Family Welfare #10551411 Price Bid
Tender For Electrification Work In Phc Building At Rajlani District Jodhpur - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
6.
Public Administrative Department #10545789 Price Bid
Work-01 , Supply And Erection Of Galvanized Iron Pole With Galvanizing Done In Single Dipping (Average Coating Thickness Minimum 65 Microns) Continuously Tapered Poles Having Octagonal / Circular Cross-Sections Designed To Withstand The Maximum Wind Speed As Per Is 875, The Pole Shaft Shall Be Made From Sheet Steel (Ht Steel Conforming To Grade S355jo) And Confirming To Bsen 10025 And Shall Be Continuously Tapered With Single Longitudinal Welding. There Shall Not Be Any Circumferential Welding. The Welding Of Pole Shaft Shall Be Done By Submerged Arc Welding (Saw) Process. Pole Shafts Shall Be Provided With The Rigid Flange Plate Of Suitable Thickness (Fe 410 Conforming To Is 226 / Is 2062) With Provision For Fixing 4 No. Foundation Bolts, This Base Plate Shall Be Fillet Welded To The Pole Shaft At Two Locations I.E. From Inside And Outside.The Octagonal Poles Shall Have Lockable Door Of Approximate 500 Mm Length At The Elevation Of 500 Mm From The Base Plate With Bakelite Sheet Having 6A Sp Mcb And 16 Sqmm Stud Type Connector ( 4 Nos) Inside The Pole At Door Opening For Cable Connection Of Following Length And Dimension As Per Table P-01 With Base Plate And Foundation Bolt On The Existing Cement Concrete Foundation.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 9 Mtr. , Supply And Fixing Of Pole Oem Fabricated Hot Dipped Galvanised M.S. Overhang (48.3 X 3.25 Mm) With Cap (400 X 88.9 / 114.3 X 3.25 Mm) Over The Existing Poles. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .Single Arm Overhang , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) <10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current <750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri >70 And Cct 5700K +355K. Surge Protection Shall Be Min = 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Led Street Light Fixture With Minimum Lumen Output 18750 Lm , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr.16 Sq. Mm 4 Core , 25 Sq. Mm 3.5 Core , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Armoured Copper Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With Electrolytic Grade Copper Made Of Copper Rods Confirming To Is 613-1964, Of Purity >99.7 %, Round / Flat Strip Armouring, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr6 Sq. Mm 3 Core , Plate Earthing As Per Is:3043 With Copper Earth Plate Of Purity >95% Of Size 600Mm X 600Mm X 3.0Mm By Embodying 3 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In-Charge During Site Visit And Ensure To Enter In Measurment Book. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Supply & Laying Following Size Earth Strip In Horizontal Or Vertical Run In Surface By Means Of Earth Strip Dmc Insulator Including Riveting/ Soldering/ Welding, Jointing Shall Be Done By Overlapping And With 2 Set Of Brass (For Cu Strip) / Gi (For Gi Strip) Nut Bolt & Spring Washer Spaced At 50Cm Making Connection Etc. As Required.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 20Mm X 3Mm Copper Strip , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsrsingle Pole Mcb (With B/C Curve Tripping Characteristics) 40 A Rating , Providing And Laying Rcc Foundation For Octagonal / Conical Street Light Poles, High Mast Poles As Per Drawing Attach At Table P-4 With Following Procedure & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .Pole Foundation For Octagonal Pole From 7 Mtr. To 9 Mtr. , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .90 Mm , Supply & Laying Following Size B Class , G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Accessories Like Bend, Socket Etc. For Laying Earth Conductor/ Strip / Cable In Ground/ Surface/ Recess As Required. All As Per Pre Approved By Engineer In-Charge. (Earth Excavation Will Be Paid Extra)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annex Ure A Attached With This Bsr . 80 Mm Dia. , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Labour Charges For Trimming Of Tree Branches/Plants And Prepairing Route Approaches For Electric Proposed Line Complete With Prior Permission Of Local Authority In Writing , Taking Proper Shutdown From Discom Office And Inform To Discom After Complete The Work. , Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:-(A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided(B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire.[C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra )(F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra )(H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Providing & Fixing Of Ac Operated Heavy Duty 230 /440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is/Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .3 Pole Power Contactors With Following Ac 3 Rating 250 Amp , Sitc Of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr4 Pole Mccb With Microprocessor Based Release With Adjustable O/L & S/C Setting With Inbuilt Instantaneous And Ground Fault Protection, 250 Amp , 50 Ka , Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Red/Yellow/Green Colour , Providing & Fixing Of Mechanical / Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 60730-1 And 60730-2-7 Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . One Day Reserve (Analog Type ) , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsrsingle Pole Mcb (With B/C Curve Tripping Characteristics) 100 A Rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
7.
Public Administrative Department #10545783 Price Bid
Work-01 , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) <10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current <750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri >70 And Cct 5700K +355K. Surge Protection Shall Be Min = 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Led Street Light Fixture With Minimum Lumen Output 3700 Lm , Led Street Light Fixture With Minimum Lumen Output 5600 Lm , Led Street Light Fixture With Minimum Lumen Output 8700 Lm , Led Street Light Fixture With Minimum Lumen Output 15000 Lm , Providing & Fixing Of Ik08 Ip-66 Protected High Power Led Flood Light System With Single Piece Pressure Diecast Aluminium Housing, Toughened Glass Diffuser With Suitable Lenses On Led To Achieve Various Beam Angles, Of High Power Led Of 3 To 5 Watt Each . Integrated Potted Driver As A Unique Bis R Number Having Efficiency More Than 85 % And In Compliance To Bis Certified And Trade Mark Certificate. The System Level Luminaire Efficacy >=125 Lm/ Wt. Led Driver Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety .Power Factor >0.95 , Thd(I) <10% , Driver Current <=750Ma. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Electrical Connector , Surge Protection Min >=4Kv Internal And 10Kv External But Inside Driver Compartment, System Life Of 50000 Burning Hours With 70% Of Initial Lumens Maintained, Cri>70 And Cct 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen Printing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . High Power Led Flood Light Minimum Lumen Output 25000 Lm , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 40 Mm Dia. , Supplying And Drawing Of Xlpe Insulated Lt Aerial Bunched Aluminium Conductor Cable Confirming To Is 14255/1995 And Is 398 (Pt-4)/ 1994 And As Per Discom Specs. On Existing Cross Arms Through I Hook With All Necessary T&P Required Including Binding And Twisting Etc. Complete In All Respect As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 1 X 25 Sq. Mm. + 1X25 Sq. Mm. (Insulated) , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr2 X 2.5 Sq.Mm , Supply And Fixing Of 11 Kv Pin Insulator Confirming To Is:731:1971 With Latest Ammendment On Existing Bracket Including All Accessories Like Ms Forged Hot Dipped Gi Pin Confirming To Is 2486(Part-I)/1993 & Is:2486 (Part-Ii)/1989 With Latest Amendment, And As Per Latest Discom Specs. Etc. As Required. All As Per Pre Approved By Engineer In-Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr , Supply And Fixing Of Following Lt Supporting Accessories With Nut Bolt & Clamps Made Out As Per Standard Discoms Specifications With Two Coats Of Red Oxide And Two Coats Of Aluminium Paint Etc. As Required. All As Per Pre Approved By Engineer In-Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Lt Cross Arm 1200 Mm Long With Clamp , Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:-(A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided(B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire.[C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 Amp ) And By Solid Bus Bar (>63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra )(F)Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra )(H) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only (Cpri Test Certificates To Be Submitted)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Plate Earthing As Per Is:3043 With Copper Earth Plate Of Purity >95% Of Size 600Mm X 600Mm X 3.0Mm By Embodying 3 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In-Charge During Site Visit And Ensure To Enter In Measurment Book. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Providing & Fixing Of Ac Operated Heavy Duty 230 /440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is/Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .3 Pole Power Contactors With Following Ac 3 Rating 250 Amp , Sitc Of 3 /4 Pole Current Limiting Moulded Case Circuit Breaker (Mccb) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440/415 V, 50 Hz; O/L & S/C Settings , Conforming To Is/Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push (Test) To Trip, Trip Time Less Then 10 Ms Under S/C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage 690 V. Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 4 Pole Mccb With Microprocessor Based Release With Adjustable O/L & S/C Setting With Inbuilt Instantaneous And Ground Fault Protection, 250 Amp , 50 Ka , Providing & Fixing Of 110/220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass (Tin Plated), Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .Red/Yellow/Green Colour , Providing & Fixing Of Mechanical / Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 60730-1 And 60730-2-7 Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . One Day Reserve (Analog Type ) , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsrsingle Pole Mcb (With B/C Curve Tripping Characteristics) 100 A Rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
8.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
9.
Public Administrative Department #10363290 Price Bid
Tender For Electrification Work From Cello Glass Were To Nimbeshwar Mahadev Temple At Khudala Falna; 1 Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .Poles with Octagonal Cross Section8 Mtr 2 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .Single arm overhang 3 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .LED Street Light fixture with Minimum lumen output 8700 lm 4 Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.Pole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr. 5 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4 Core 10.0 Sq. mm 6 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 7 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure A attached with this BSR 1.5 Sq. mm 2 Core 8 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .One day & week reserve (Analog type ) 9 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR pole Power contactors with following AC 3 Rating 40 Amp 10 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional tech Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 11 Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Four pole Isolator 40 A rating 12 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 13 Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 14 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .8 SWG G.I. ( Hot Dipped ) Wire 15 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .B class 50mm dia 16 Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety.Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screenrinting on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 omplianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .High Power LED Flood Light Minimum lumen output 25000 lm 17 Supply installation testing & Commissioning of high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly ) foundation bolt, torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required on Existing Foundation. ( See table P - 03 for specs.) OEM Must have Type test certificate for wind tunnel test . All as per pre approved by Engineer in-charge. All as per pre approved by Engineer in-charge. For additional technical parameters of product12.5 Mtr HM (in 2 section) suitable for 6 No. Luminaries 2 no. rope for lantern carrage & 2 no. rope for winch assembly
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
10.
Health and Family Welfare #10363172 Price Bid
Tender For Electrification Work In Phc Building At Khetasar Block Osian District Jodhpur; 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 2.0 TR ISEER not less then 3.8 81 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 25 mm 83 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 85 150 mm dia per running inch length 86 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 87 4 kVA 88 5 kVA 89 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 90 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 91 Surface Mounting (with extruded alumn. Housing ) 92 Minimum lumen output 1950 lm 93 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 95 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 4 kg 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 15 Ltr. 99 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 2 pair 101 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 102 10 Pairs 103 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 104 RJ-11 telephone jack singleline 105 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Cat 6, Un-sheilded Information Outlet 108 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 Single Aperture 110 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 112 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 Modular Patch Panel Loaded with Cat -6 I/O 114 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 24 Port 116 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 117 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 118 Recessed Mounting 119 Minimum lumen output 4200 lm 120 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 121 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 122 1 Mtr 123 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 3.5 x 25.0 sq.mm 125 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 126 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 127 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 128 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 130 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 132 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 133 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 134 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 135 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 136 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 137 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 138 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 139 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 140 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 141 Ring type tape wound CT 142 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 143 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Red/yellow/Green colour 145 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 146 Electrolytic grade Aluminium bus bar 6010 grade 147 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 148 Two pole 100/300mA sensitivity 149 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
11.
Housing Urban and Rular Development #10350279 Price Bid
Tender For Construction Of Labour Ward In Hostpitalgangashahar - Bikaner ( Electricalwork ) Construction Of Labour Ward In Hostpital Gangashahar - Bikaner ( Electricalwork ) - 1 Note:-Please read Annexure A for each Items if not uploaded in e tender, see on pwdraj website.Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 On board 7 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories with own OEM CM/L No. as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 8 20 mm 9 25 mm 10 32 mm 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 2 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 1 x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 1 x 6.0 sq.mm 16 4 x 16.0 sq.mm 17 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 18 Single pole MCB (With B/C curve tripping Characteristics) 19 6 A to 32 A rating 20 Four pole MCB (With B/C curve tripping Characteristics) 21 50/63 A rating 22 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 23 Metal door (Three phase) IK-09 and IP-43with Metal end box 24 6 Way 25 Providing & Fixing ofISI marked (IS:1293) 16 ampunbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 26 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-2rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 27 25 Amp.2 Moduleswitch With LedIndicator 28 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 29 25 Amp. 2 Module Socket 30 Providing & Fixing of modular type 100/120W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-2rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 5 step fan regulator 2 Module 32 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 33 Blanking plate 34 Modular MCB 6 A to 32 ASP 35 Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 36 1/2 Module 37 3 Module 38 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 1-2 Module 40 3 Module 41 Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR 42 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 43 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 44 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 45 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 46 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 47 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 48 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 49 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 50 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 51 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade 54 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 Blue / white Colour 56 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 57 4 pole MCCB With Thermal Magnetic release 58 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 59 200 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 60 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 61 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 62 Providing & Fixing of IK08 and IP-30 Recessed/surface mounting heavy duty Enclosuresuitable for mounting 3 / 4 pole MCCB, Inbuilt neutral linkmade out from Galvanized steel / CRCA sheet not less then 1.2 mm thickconforming to IS-8623-1 & 3 /IEC 61439- 1 & 3. powder painted complete with din railmaking internal DBterminations,detachable gland plate, including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 Suitable to accommodate up to 70 sqmm 3.5 core Al arm. Cable 64 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 Open execution type 66 400 A 67 Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/ IS-8623 & IEC-60529/ IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. Capacity, bus barfixed on porcelain/DMC insulators at approved spacingincluding making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 68 450 mm long , 4 strip 69 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure A attached with this BSR 70 95.0 Sq. mm 71 3.5 core 72 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 73 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 74 Supplying and makingend termination with heavy aluminiumlugs ( Pin / ring type )confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 75 50.0 Sq.mm 76 95.0 Sq.mm 77 Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 78 300mm x 50mm x 1.6mm 79 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 63mm 81 Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. (d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 82 17.2 mm thick and 3 Mtr. Long 83 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 84 32mm x6mm G.I. ( Hot Dipped) Strip 85 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 86 10 SWG G.I. ( Hot Dipped) Wire 87 Supply & Fixing of phenolic laminated boardof 6.4 mm thick forfresh air fan/exhaust fan up to size of 300 mm onexisting window frame including cost of board, cutting of hole , Nut bolts etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 89 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 90 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side complete with minimum weight of 750 gm. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 91 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 225 mm sweep 93 300 mm sweep 94 Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 95 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 Up to 380 mm size 97 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 98 25 Ltr. 99 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR 100 Recessed Mounting 101 Minimum lumen output 1300 lm 12 W 102 Minimum lumen output 1950 lm 18 W 103 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 104 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Recessed Mounting 106 Minimum lumen output 4200 lm 36W 107 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 108 4 kg
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
12.
Public Administrative Department #10350093 Price Bid
Tender For Work Of Installing Lights In Municipal Area Mahwa District Dausa - Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 2 LED Street Light fixture with Minimum lumen output 5600 lm 3 LED Street Light fixture with Minimum lumen output 3700 lm 4 LED Street Light fixture with Minimum lumen output 8700 lm 5 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .40 mm Dia. 6 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .32 mm Dia. 7 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12x 1.5 sq.mm 8 Supplying and drawing ofXLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1X25sq.MM.+1X25 sq. mm. (Insulated) 9 Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discoms standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming toIS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer incharge.For additional technical parameters of product / work refer Annexure A attached with this BSRSuspension clamp with yey hook & pole clamp 10 Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. completeas per technical specification of DISCOM. 11 Supply & Laying following size B class ,G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in-charge.(Earth Excavation will be Paid Extra)All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR .6 SWG G.I. ( Hot Dipped) Wire 12 Providing & Fixing ofAC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .4 pole Power contactors with following ac 1 rationg 63 Amp 13 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSRpre approved by Engineer in-chargeup to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 14 Providing & Fixing of 240/415 V isolatorISI marked IS:13947 III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering overall poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSRFor pole Isolator 63 A rating 15 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, erusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 16 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer Annexure A attached with this BSR single opole McB (With B/c Curve tripping characteristics )6 A to 32 A rating 17 50/63 Arating 18 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .One day & week reserve (Analog type )
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
13.
Health and Family Welfare #10276803 Price Bid
Tender For Electrification Work At Construction Of Chc Building At Jhinjhiyali District Jaisalmer - Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 20 mm 13 25 mm 14 32 mm 15 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 16 1 x 1.5 sq.mm 17 2 x 2.5 sq. mm. + 1x1.5sqmm 18 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 19 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 20 1 x 4.0 sq.mm 21 4 x 6.0 sq.mm 22 4 x 10.0 sq.mm 23 Providing & Fixing of ISI marked surface type buzzer (IS:2268-1994) with CM/L no. printed including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 24 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 25 75 mm dia 26 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 27 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 28 5 step fan regulator 2 Module 360 dgree rotating 29 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 30 Blanking plate 31 25 Amp. 2 Module Motor Starter with on / off Push button 32 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 33 25 Amp. 2 Module Socket 34 Providing & Fixing ofextra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe including cutting, threading, drilling, fixing quarter pin etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 35 P & F of Gravity Louver shutter of superior quality made out of frame of18 swg M.S. sheet & Louvers made from 24 swg MS Sheetwith enamel paint including cost of nuts, bolts, etc as reqd.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 36 Up to 380 mm size 37 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 38 3 pair 39 5 pair 40 50 pair 41 20 pair 42 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 43 20 Pairs 44 50 Pairs 45 P & F 1.2 mm thickG. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 46 1.2 mm thickM. S. Sheet boxes 47 175mm x 100mm x 60mm 48 P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 49 3.0 mm thick 50 Providing & Fixing of flush typenon modular single line telephone jackmade out fromindustrial grade Polycarbonate or fire resistant ABS material, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 51 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 52 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 Cat 6, Un-sheilded Information Outlet 54 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 Single Aperture 56 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 57 Single pole MCB (With B/C curve tripping Characteristics) 58 6 A to 32 A rating 59 Triple pole MCB(With B/C curve trippingCharacteristics) 60 6 A to 32 A rating 61 50/63 A rating 62 Four pole MCB (With B/C curve tripping Characteristics) 63 6 A to 32 A rating 64 50/63 A rating 65 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 66 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 67 6Way(Incomer 8,Sub Incomer2+2+2) 68 8Way(Incomer 8,Sub Incomer2+2+2) 69 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 70 Two pole 100/300mA sensitivity 71 63 A rating 72 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 160 (upto 160 A Incomer) / 250 Amp. copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 73 Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal end box 74 6 Way 75 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 76 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 77 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 78 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 79 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 80 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 81 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 82 17.2 mm thick and 3 Mtr. Long 83 Plate Earthing as per IS:3043 withcopper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 84 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 85 25mm x 3mm copper strip 86 25mm x 3mm G.I. ( Hot Dipped) Strip 87 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 89 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 90 300 mm sweep(900/1400 RPM) 91 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 225 mm sweep 93 Providing & Fixing of 450 mm SweepOscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Sintered Iron bush oil impregnated,with metal front and back 120 or moreribs guard; Three no. Aluminiumblades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 Wall mounting type with Adjustable Vertical Angle 95 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 97 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 98 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 99 Surface Moutning 100 Minimum lumen output 3600 lm 101 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 102 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 103 Surface Mounting (with extruded alumn. Housing ) 104 Minimum lumen output 1950 lm 105 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 106 6.0 Sq. mm 107 4 core 108 10.0 Sq. mm 109 4 core 110 16.0 Sq. mm 111 4 core 112 25.0 Sq. mm 113 3.5 core 114 50.0 Sq. mm 115 3.5 core 116 70.0 Sq. mm 117 3.5 core 118 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 4 x 6.0 sq.mm 120 4 x 10.0 sq.mm 121 4 x 16.0 sq.mm 122 3.5 x 70.0 sq.mm 123 3.5 x 50.0 sq.mm 124 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 125 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 126 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 127 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 128 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 129 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 130 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 131 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 132 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 133 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 134 Electrolytic grade Aluminium bus bar 6010 grade 135 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 136 Three phase Ammeterwith Inbuilt Selector Switch 137 Three phase Voltmeter with Inbuilt Selector Switch 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio upto 150/5, Burden 5 VA 141 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 142 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 143 Red/yellow/Green colour 144 Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 145 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms) 146 Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs(temp class - 25 D)in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 147 Heavy dutyThree phase 480 V, 50 Hzcylindrical type capacitor (Bank) 148 Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phasesensing compensationpower factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485,indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 149 6 to 8 stage 150 Providing & Fixing of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 151 up to 6 KVAR 152 10 KVAR 153 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 154 3 pole MCCB With Thermal Magnetic release 155 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 156 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 157 4 pole MCCB With Thermal Magnetic release 158 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 159 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 160 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 161 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 162 LED Street Light fixture with Minimum lumen output 3700 lm 163 LED Street Light fixture with Minimum lumen output 8700 lm 164 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 165 SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal - T/C Vs T/C, Thrust bearing shall be ofcarbon + S.S.The stator body of single phase pumpshall be of SS and rest of all shall be of cast iron. All casting parts should be cathod electro deposition (CED) coated and other construction material should be confirming to IS : 14220: 2018 . The overall performance of pump shall confirm to BEE energy efficiency level of 3 star. Valid BEE certificate from OEM must be submitted for the same. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011, including making connection etc as required complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 166 1.5 HP, 1-Ø, (18 -26) Mtr, (126 - 78) LPM 167 Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 168 B class 50mm dia 169 SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 170 For Three phase Submersible / Mono block pump 171 3.0 HP to 5.0 HP ( Star / Delta starter ) 172 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 173 6.0 Sq.mm 3 core flat / Round 174 Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 175 150mm x 50mm x 1.6mm 176 P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 177 50mm x 50mm x 6mm 178 35mm x 35mm x 5mm 179 Providing & Fixing ofCam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 180 10 AMP 181 32 AMP 182 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Open execution type 184 125 A 185 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 186 Poles with Octagonal Cross Section 187 7 Mtr. 188 Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window,PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0sq.mm heavy duty connector, earth terminal,complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 189 160 mm X 225 mm X 100 mm 190 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 191 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 192 1/2 Module 193 3 Module 194 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 195 1-2 Module 196 3 Module 197 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 15 Ltr. 199 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 Single arm overhang 201 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emissionnorms) havingspecifications as per A, B, C, D, E, F,G,H & I 202 A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP(up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation.,Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber),up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required . 203 B)AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled 204 C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade. 205 D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger,Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : 206 E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm forrating above 250 KVA. 207 F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. 208 G) Servicing Contract of DG Set from OEMs Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department. 209 H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. 210 I) DG set will be offered for Inspection and Testing at Manufacturers Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 211 50 KVA at 0.8 pf 415V 50Hz 3-ǿ 212 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 213 50 to 82.5 KVA 214 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 215 8 SWG copper Wire 216 Providing, Fixing, Jointing, Testing & Commissioning of Medium duty MS B class pipes conforming to IS 3589 / 1239 part-I for DG Exhaust applications (beyond 1.5 Mtr. length)includingcutting,welding etc & fittings like elbows,flanges, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts . including the cost of thermal insulation with 50 mm thick layers of LRB rock wool as per IS : 8183-1993 (64 kg/m3 density) & 26 SWG aluminium sheet claddings etc complete as required complete in all respect.(Cost of Steel Structure for Exhaust pipe will be paid Extra). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 217 125 mm dia 218 P & F of Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 219 Supply, installation, testing & commissioning of following size & Material air termination rods confirming to IEC/EN 62561 with suitable OEM recommendedmounting arrangement on parapet wall all as per standard , complete as required. the test report accredited by third party accreditation body like VDE/ ILAC/ DAkkS/ UL/ NABL is to be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 220 1500 mm long, 10 mm Dia. Aluminium / AlMgSi 221 Supply & Fixing Air-termination rod clamps for connecting air-termination rods with one or two conductors. Material of clamp Al, with clamping range of air-termination rod 10 / 16 mm and Clamping range of conductor Rd 2x 8-10 mm, & Complied as per Standard EN 62561-1, tested to carry from 100KA (10/350μs) lightning current the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 222 Supply and Fixing of stainless steel clamp for holding 8mm dia. conductor on Parapet Wall / Side Fl 20 mm, Height- 20 mm & Complied as per Standard EN 62561-4. With accessories SS Screw and Gitty etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 223 Supply & LayingofAluminum / SS / AlMgSi Round Conductor confirming to IEC/EN 62561 etc. as required. the test report accredited by third party accreditation body like VDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. ( Supporting Clamps to be paid Extra )All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 224 8 mm Dia. Aluminium conductor 225 Supply and Fixing of Test Joint (Folding Clamp) made of SS,suitable to connect 8mm round conductor with25 mm x 6 mm GI strip etc. as required. the test report accredited by third party accreditation body likeVDE/ILAC/ DAkkS/ UL/ NABL is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 226 Supply, Installation, & Testing of 19 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 227 24 Ports 228 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 229 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 230 1 Mtr 231 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 232 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 233 Supply , Installation, Testing and Comissioning ofManaged Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 234 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 235 1.5 TR ISEER not less then 3.8 236 2.0 TR ISEER not less then 3.8 237 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 238 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 239 4 kVA 240 5 kVA 241 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 242 25 mm 243 SITC of Interconnecting refrigerantcopper pipe forsplit/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizesas per OEM requirement & specifications including class O Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 244 Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existingsurface or recessed PVC/ MS conduit/casing capping/ Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 245 Armoured 246 4 core x 2.5 Sq.mm 247 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 249 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 250 4 kg 251 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 252 Capacity 4.5 Kg.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
14.
Health and Family Welfare #10187107 Price Bid
Tender For Electrification Work In Phc Building At Moriya District Phalodi - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
15.
Health and Family Welfare #10187103 Price Bid
Tender For Electrification Work In Phc Building At Bhudkiya District Jodhpur Rural - 1 (Electrical BSR 2022 Rajasthan) Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR. Short point (up to 3 mtr.) 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Medium point (up to 6 mtr.) 7 Long point(up to 10 mtr.) 8 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 9 On board 10 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 11 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 3x 1.5 sq.mm 13 2 x 2.5 sq. mm. + 1x1.5sqmm 14 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 15 4 x 10.0 sq.mm 16 4 x 6.0 sq.mm 17 1 x 2.5 sq.mm 18 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 19 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 20 6Way(Incomer 8,Sub Incomer2+2+2) 21 Metal door (single phase) IK-09 and IP-43 with Metal end box 22 16 Way (16+2) 23 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Single pole MCB (With B/C curve tripping Characteristics) 25 6 A to 32 A rating 26 Four pole MCB (With B/C curve tripping Characteristics) 27 40 A rating 28 Double pole MCB(With B/C curve tripping Characteristics) 29 6 A to 32 A rating 30 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 31 20 mm 32 25 mm 33 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 34 75 mm dia 35 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 36 5 step fan regulator 2 Module 360 dgree rotating 37 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 38 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 300 mm sweep(900/1400 RPM) 40 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 41 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 42 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 44 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 225 mm sweep 46 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 47 25.0 Sq. mm 48 3.5 core 49 6.0 Sq. mm 50 2 core 51 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 52 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 54 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 55 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 56 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 57 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 58 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 59 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 60 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 17.2 mm thick and 3 Mtr. Long 62 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 8 SWG G.I. ( Hot Dipped) Wire 64 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 LED Street Light fixture with Minimum lumen output 2450 lm 66 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 25 mm Dia. 68 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 69 4 pole MCCB With Thermal Magnetic release 70 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 71 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 72 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 73 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 74 32 amp, 5 pin + scrapping Earth, 8 Module 75 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Open execution type 77 63 A 78 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 79 1.5 TR ISEER not less then 3.8 80 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 25 mm 82 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia 84 150 mm dia per running inch length 85 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 86 4 kVA 87 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 88 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 89 Surface Mounting (with extruded alumn. Housing ) 90 Minimum lumen output 1950 lm 91 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 92 1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 93 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 4 kg 95 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 96 15 Ltr. 97 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 98 2 pair 99 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 100 10 Pairs 101 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 102 RJ-11 telephone jack singleline 103 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 104 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 105 Cat 6, Un-sheilded Information Outlet 106 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 107 Single Aperture 108 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 109 6 U Rack with Width 600 mm &Depth 400 mm + 100 mm 110 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 Modular Patch Panel Loaded with Cat -6 I/O 112 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 113 24 Port 114 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 115 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 116 Recessed Mounting 117 Minimum lumen output 4200 lm 118 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 119 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 120 1 Mtr 121 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 122 3.5 x 25.0 sq.mm 123 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 124 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 125 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 126 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 127 cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 128 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 129 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 130 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 131 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 132 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 133 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 134 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 135 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 136 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 137 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 138 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 139 Ring type tape wound CT 140 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 141 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 142 Red/yellow/Green colour 143 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 144 Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Contract Date: Ref. Documents Contract Value : 2.55 Lakh
Government Departments No of Bidders 2
Maharashtra View Result →
17.
Public Administrative Department #9943428 Technical Bid
Tender for Supply Installation Testing and Commissioning of Street Light Pole And Phase Wire In Muncipality Area , Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy =125 Lm/ Wt And Potted Driver & Has A Unique Bis R Number With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety , Power Factor 0.95 Driver Efficiency 85% ,Thd(I) 10% Humidity 10% To 90% Rh Working Temp -5C To 45C . Driver Current 750Ma. The Luminaire Shall Be Bis Certified And Trade Mark Certified. Life Expectancy Equal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri 70 And Cct 5700K +355K. Surge Protection Shall Be Min ≥ 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Led Street Light Fixture With Minimum Lumen Output 3700 Lm , Led Street Light Fixture With Minimum Lumen Output 12500 Lm , Supply And Erection Of Galvanized Iron Pole With Galvanizing Done In Single Dipping (Average Coating Thickness Minimum 65 Microns) Continuously Tapered Poles Having Octagonal / Circular Cross-Sections Designed To Withstand The Maximum Wind Speed As Per Is 875, The Pole Shaft Shall Be Made From Sheet Steel (Ht Steel Conforming To Grade S355jo) And Confirming To Bsen 10025 And Shall Be Continuously Tapered With Single Longitudinal Welding. There Shall Not Be Any Circumferential Welding. The Welding Of Pole Shaft Shall Be Done By Submerged annual rate contract Welding (Saw) Process. Pole Shafts Shall Be Provided With The Rigid Flange Plate Of Suitable Thickness (Fe 410 Conforming To Is 226 / Is 2062) With Provision For Fixing 4 No. Foundation Bolts, This Base Plate Shall Be Fillet Welded To The Pole Shaft At Two Locations I.E. From Inside And Outside.The Octagonal Poles Shall Have Lockable Door Of Approximate 500 Mm Length At The Elevation Of 500 Mm From The Base Plate With Bakelite Sheet Having 6A Sp Mcb And 16 Sqmm Stud Type Connector ( 4 Nos) Inside The Pole At Door Opening For Cable Connection Of Following Length And Dimension As Per Table P-01 With Base Plate And Foundation Bolt On The Existing Cement Concrete Foundation.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .Poles With Octagonal Cross Section 8 Mtr , Supply And Fixing Of Pole Oem Fabricated Hot Dipped Galvanised M.S. Overhang (48.3 X 3.25 Mm) With Cap (400 X 88.9 / 114.3 X 3.25 Mm) Over The Existing Poles. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . Single Arm Overhang , Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 25 Mm Dia. , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 2 X 1.5 Sq.Mm , 3X 1.5 Sq.Mm , Supply And Fixing Of Following Lt Supporting Accessories With Nut Bolt & Clamps Made Out As Per Standard Discoms Specifications With Two Coats Of Red Oxide And Two Coats Of Aluminium Paint Etc. As Required. All As Per Pre Approved By Engineer In-Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Suspension Clamp With Eye Hook & Pole Clamp , Supply And Fixing Of Lt Porcelain Shackle Insulator As Per Is:1443 1979 And As Per Discoms Standard Specifications, Suitable For Working Voltage 1100 Volts Including All Accessories Like Gi Hardware Fittings Confirming To Is:7935/1975 (Latest Amended) Nut, Bolt Etc. As Required. All As Per Pre Approved By Engineer In-Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 100Mm X 110Mm , Supplying And Drawing Of Xlpe Insulated Lt Aerial Bunched Aluminium Conductor Cable Confirming To Is 14255/1995 And Is 398 (Pt-4)/ 1994 And As Per Discom Specs. On Existing Cross Arms Through I Hook With All Necessary T&P Required Including Binding And Twisting Etc. Complete In All Respect As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 1 X 25 Sq. Mm. + 1X25 Sq. Mm. (Insulated) , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray(With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 16.0 Sq. Mm; 4 Core , P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class 750 N, Externally Corrugated And Having Smooth Surface Inside With Hdpe Coupler, Elbow, Tee At Required Depth Below The Ground For Laying Cable Of Following Nominal Outer Dia. Mfr Test Report From Nabl Accrediated Is To Be Submitted.(Excavation Of Earth & Back Filling With Compaction Is To Be Paid Extra)All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 50 Mm , Pipe Earthing As Per Is:3043- 1987 With 3.0 Mtr. Long, 40 Mm Dia. B Class G.I. Pipe Is: 1239 (Part-1) 2004, Equivalent To Bs : 1387 With Perforated Holes Of 12 Mm Dia ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In-Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Providing And Laying Reinforced Cement Concrete Foundation For Octagonal / Conical Street Light Poles, High Mast Poles As Per Drawing Attach At Table P-4 With Following Procedure & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . A) Excavation Of Pit For Foundation Size Upto Required Depth From Ground Level B) Dressing Of Pit And Dry Stone Pitching 200 Mm Thick Including Supply Of Stones And Preparing Surface Complete. C) Providing And Laying In Position Cement Concrete Of M-10 Grade Of 75 Mm Thickness D) Reinforcement For Reinforced Cement Concrete Work With Tmt Bars Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. E) Centring And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Footing And Pedestal F) Providing & Fixing Of 2 No. Required Size Plb Hdpe Pipe & Foundation Bolt With Template As Per Oem Recommendations.G) Providing And Laying Reinforce Cement Concrete Of M-25 Grade In Footing And Pedestal Including Curing The Foundation For 7 Days. H) Providing And Fixing Nosing Angle 40 Mm X 40 Mm X 6Mm With 2 No. 100 Mm Long, 10 Mm Dia. Lugs On Each Face. Pole Foundation For Octagonal Pole From 7 Mtr. To 9 Mtr. , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm(Width) , With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Add Extra In Item No.60.5 If Excavation Done In Hard Rock / cement concrete Road / Tar Road And Making Good The Same , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb (With B/C Curve Tripping Characteristics) Single Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating , Four Pole Mcb (With B/C Curve Tripping Characteristics) 40 A Rating , Providing & Fixing Of Ac Operated Heavy Duty 230 /440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is/Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . 4 Pole Power Contactors With Following Ac 1 Rating, 40 A Rating , Providing & Fixing Of Mechanical / Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 30-1 And 30-2-7 Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . One Day & Week Reserve (Analog Type ) , Supply Installation Testing and Commissioning of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall/ Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point (A) ,(B), (C),(D), (E), (F), (G), (H) As Below:- (A)Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided (B)Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam/ Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness ,Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment/Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire.[C) Interconnection Between Bus Bar And Switchgears /Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires (Up To 63 annual periodical maintenance ) And By Solid Bus Bar (63 annual periodical maintenance ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra )(D)Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. (E)All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point (No Wire Splitting Or Tee , Supply And Installation Of Spike Of M.S. Rod 20Mm Dia 3.0Mtr. Long For Earthing Of (Tower/Pole) Drive Into Earth By Mechanical Means Sturcture Connection The Spike With Cross Arm Top Hamper Plain Cement Concrete Pole, Lattics Tower To Earth Etc. Complete As Per Technical Specification Of Discom.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 8
18.
Heavy Industries and Public Enterprises #9839854 AOC
Bids Are Invited For Pickling Bath And Pvc Tank Total Quantity : 1
Contract Date: Ref. Documents Contract Value : 9.62 Lakh
Boards / Undertakings / PSU No of Bidders 5
Contract Date: Ref. Documents Contract Value : 3.65 Lakh
Government Departments No of Bidders 11
Madhya Pradesh View Result →
20.
Defence #9578058 AOC
COMPREHENSIVE REPAIRS / MAINT OF 33/11 KV MRS AT SUNDERABANI UNDER GE(N) AKHNOOR AND COMPREHENSIVE REPAIR/MAINT OF HT CABLE, BUS BARS, EARTHINGS, ACSR CONDUCTOR, CLEANING OF BUSHES &BRANCHES AT BARAKH AND SUNDERBANI AREA UNDER GE (N) AKHNOOR; 1 Supply and fixing in replacement of GOD 33 KV rotating , horizontal type,double break triple pole outdoor gang operated centrepost rotating manually operated isolator switch 400 Amp having 12.5 KA (RMS) for 3 sec short circuit rating with 9 nos 33 kv capacity and pin type post insulator with 320 mm cleavage distance and pedestal of height of 200mm to maintain line earth clearage of 370mm mechanically inter locked triple pole earthing with having independent manually operated handle complete with all supporting stucture of suitable channel, nuts & bolts etc complete all as specified and directed. 2 M&L for scrapping laid out aggregate of any size and removing from site and cleaning of dirt and vegetation from site and relaying of the same in switchyards complete all as specified and directed. 3 M&L for painting of HT 33 KV HT grid steel structure including all MS channel isolators, CTs, PTs and MOCBs, VCBs, bus bar and other steel structure with synthetic enamelled aluminium paint on structure abd other colour code for equipment after proper surface preparation complete all as specified and directed. 4 M&L for Jumpers works in PTs, CTs, MOCBs, isolator, DO fuse by using parallel grove clamp, Tee clamp Tee clamps other connectors required by using ACSR conductor any sizess (Dog/Mouse)including dismantling old conductor and clamp complete all as specified and directed. 5 M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to DB/Panel by using GI strip of 32x6 mm sleeved using red colour PVC sleeving as earthing lead soldering/rivetted to earth plate at one end and connected to existing structureby means of nut, bolts etc complete with PCC pit (1:3:6) type PCC cover with handle, funnel with watering pipe wire mess GI protection pipe for earthing lead complete all as specified and directed. 6 Supply and fixing Danger notice plate of 1.6 mm thick MS sheet,vitreous enamelled white with letters, figures and conventional skull and bones with MS clamp, bolts and nuts of approved size for HT, 25x20 cm,(33KV/ 11 KV mark complete all as specified and directed. 7 M&L for steel tubular swaged type poles 11 metrs long,pole weight approximately 227 kgs, pole should be in one piece only and smooth finishing and smooth finishing of pole,ISI marked complete with all accessories such as cast iron base plate, finial taper plug,bolts, nuts, screws,washers and drilling of holes for continious GI earth wire as specifiedtype 410 SP-55 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface complete all as specified and directed. Make as approved by GE. 8 M&L for steel tubular swaged type poles 12 metrs long,pole weight approximately 292 kgs, pole should be in one piece only and smooth finishing and smooth finishing of pole,ISI marked complete with all accessories such as cast iron base plate, finial taper plug,bolts, nuts, screws,washers and drilling of holes for continious GI earth wire as specifiedtype 410 SP-64 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface complete all as specified and directed. Make as approved by GE. 9 Labour for complete Overhauling and Servicing of 33 KV out door type VCB including disassembly of operating mechanism parts,spring charging motor andmechanism well cleaning with petrol and CRC-226, replacing unserviceable spare parts/accessories i.e incoming jumper connection,bushing holding moving and fixed contact assembly,GO rod,inter connection assembly,spring charge mechanism and oiling and greasing of moving contacts and fixing contact parts and checkingof pole insulators,checking of vacuum interrupters, incoming and outgoing terminals,flexible connections,suporting insulators,operating rod, tie barcommon operating shift,operating corn, locking cam ,making spring,breaking spring,loading spring,and main linkwell cleaning mechanism linkages drive insulators and fiber reinforced plastic frame around the vacuum interrupters including routine and periodical test, complete all as specified and directed.(Note : Supply only spares will be measured and paidseparately) 10 Supply only spring charging motor with gear and connector for VCB of voltage 30 Volts DC or as required at site compatible with OD VCB 11 Supply only Closing and tripping coil for SF6/VCBas per site requirements. 12 Supply only Auxillary switch for 33/11VCB as per site requirements. 13 Supply only Limitswitch for33 KV VCB as per site requirements. 14 Supply only Hooter suitable for 33/11 KV breaker as per site requirements. 15 Supply only T&C switch with locking arrangement.suitable for 33 KV breaker 16 Supply only Remote selector switch incl control wiring suitable for 33 KV breaker 17 Supply only LED Indicating lamps of desired colour dual input type. 18 Supply only Vaccum Interrupting unit (bottle type) suitable forSF 6 breaker 19 Supply only IDMT,IDMTL relays suitable for 33 kv breaker and calibration through primary and secondary testing and connected accessories for functional requirement checking of electrical wiring system and testing complete all as specified and directed. 20 Supply only Control Cable 8 core armoured control2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unitcomplete all as specified and directed. 21 Supply only Control cable 4 core armoured control cable 2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unitcomplete all as specified and directed. 22 M&L forgalvanised cross arms,bracings,supports,clamps, angles,hellowbars square/round,flat irons etc and back plates fabricated in structural steel sections including nuts, bolts,washers, welding, bending, fabrication, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coatand anti corrosive silver paint one undre coat and one finishing coatand including removing old unserviceable item complete all as specified and directed 23 Supply and fix and in repair 11 KV out door type Air Breakgang operated device of rating400 Amps, triple pole, vertical type,mechanically operated, mounted onHT insulators 15 Nos, incl drop out fuse assy and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium gradewith operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supplycand testing complete all as specified and directed. 24 Supply and fix and in repair 11 KV out door type Air Breakgang operated device of rating200 Amps, triple pole, vertical type,mechanically operated, mounted on HT insulators 15 Nos, incl drop out fuse assy and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium gradewith operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supplycand testing complete all as specified and directed. 25 M & Lfor PCC 1:3:6 type C-1 (using 20 mm graded aggregate). For foundation, filling,mass concrete, coping etc incl finishing of external surfaces without applying extra cement incl dismantaling old PCCcomplete all as specified and directed. 26 M & Lfor PCC 1:4:8 type D-2 (using 40 mm graded aggregate). For foundation, filling,mass concrete etc incl dismantling old PCC complete all as specified and directed. 27 Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, HT electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 95 Sq mm, 3 core complete and taking down of UNSV HT cable from existing site complete all as specified and directed. 28 Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, HT electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 120 Sq mm, 3 core. complete and taking down of UNSV HT cable from existing site complete all as specified and directed. 29 M & L for excavation in trenches soft loose soil ,for laying under ground cable, errection of poles and stays in any type of soilnot exc 1.5 Mtr wide and not exc. 1.5 m in depth for foundation and getting out complete all as specified and directed. 30 M & L for excavation in trenches,for laying under ground cable,pipe lines, errection of poles and stays in any type of soilnot exc 3.0 Mtr wide and not exc. 3.0 m in depth for foundation and getting out complete all as specified and directed. 31 M & L for returning filling in including spreading, levelling, watering and ramming in layers not exceeding 25 cm thick with earth obtained from excavationcomplete all as specified and directed. 32 M & L for removal of surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting pointcomplete all as specified and directed. 33 M & L for unwashed sand cushioning below and around cable in trenches with river sandcomplete all as specified and directed. 34 Supplying and laying un-reinforced precast concrete cable cover HV, Type 1, flat, size 300mmx l80mm x 40mmcomplete all as specified and directed. 35 S & F 80mm bores of tubes light grade galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cablecomplete all as specified and directed. 36 Supply and fixing cable jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and directed. 37 Supply and fixing cable jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 120 sqmm to 185 sqmm complete all as specified and directed. 38 Supply and fixing cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and directed. 39 Supply and fixing cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 120 sqmm to 185 sqmm complete all as specified and directed. 40 Supply and fixing cable straight through jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and directed. 41 Supply and fixing cable straight through jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 120 sqmm to 185 sqmm complete all as specified and directed. 42 Supply insatallation, testing and commissioing of maintenance free cemical earthing based on 300mm long GI earthing Electrode (Met -Chem) 80mm outer dia and inner rod with 10mm thickness 3000 mm long duly filled with ITPC-EECP15fixed with nuts an bolts incl excavation/ earth work in any strata & PCC chamber with CI Frame and cover (Earth pit not less than 2.25 mtrs below ground level). The electrode is surrounded by chemical (ITPC-EECP15) a mixture of sulphate, silica, Iron Oxide etc, magnesium oxide, sodium oxide, zinc oxide etc. Each Earth electrode should have resistance <2 Ohm by using earth electrode is used as per the site requirements. Chemicals compound powder to be provided minimum 50Kg per site. The inspection joint provide for earthing reference incl the man hole cover with locking facility be provided. 43 S&FCopper strip of size 20 x 3 mm as in earth continiuty conductor fixed to wall on batten or recess or cases or buried in ground or any other situation for loop earthing as required at site complete all as specified and directed. 44 Disconnecting electrical connections from HT 33/11 KV, capacity 1.25 MVA transformer of any descriptions by opening of earth & control connections of any type, sealing of oil leakage, replacement of unserviceable parts and cleaning the transformer, including making all HT connections, control cable connection, earth connection etc including testing the transformer after necessary repairs complete all as specified and directed.Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items. 45 Supply and fixing in replacement of primary coil of HT 33/11 KV,capacity 1.25 MVA transformer of any specification, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications complete all as specified and directed.Note: Primary coil shall have same number of turns of winding wire and with matching to manufacturer design. 46 Supply and fixing in replacement of secondary coil of 33/11KV, capacity 1.25MVAtransformer of any capacity, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications,complete all as specified and directed.Note: Secondary coil shall have same number of turns of winding wire and with matching to manufacturer design. 47 Replacement of old unserviceable/ damaged 33 KV HT bushing assembly with new HT bushing assembly with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, any capacity complete all as specified and directed. 48 Replacement of old unserviceable/ damaged 11 KV HT bushing assembly with new HT bushing assembly with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, of any capacity,complete all as specified and directed. 49 Dehydration and filtration of 33 /11 KV transformer oil after draining out oil from transformer by the dehydration machine at site or nearby transformer workshop to achieve di-electric strength 50 KV at 4mm gap,complete all as specified and directed.Note: (i) Cost of transportation of dehydration machine and other required materials and tools, plants shall be deemed to be included in the quoted rates.(ii) Test certificate of di-electric strength from auth Lab shall be produce before and after dehydradation and filtration process for each transformer. 50 M&L for Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel suitable for 33/11 KV transformer including nuts, bolts and washerscomplete all as specified and directed. 51 Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel capacity 500 gm suitable for 11/.440 KV transformer including nuts, bolts and washerscomplete all as specified and directed. 52 Supply only fresh transformer oil to top-up and filling in the existing transformer, di-electric strength not less than 45 KV, meeting Bureau of Indian Standards: IS 335-1993 (Reaffirmed-2005) specification,examined in a 100mm thick layer at 270°C, clear, transparent and free from all type of suspended matter or sediment,complete all as specified and directed. 53 M&L Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, 33000 voltscomplete all as specified and directed. 54 M&L Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, 11000 volts complete all as specified and directed. 55 S&F Disc type insulator porcelain, vitrous 145 mm high and 255 mm dia ball and socket type, (white, brown or green) complete single disc assembly for ACSR conductor having working pressure 11000 volts gradecomplete all as specified and directed. 56 S&F Pin type, porcelain, vitreous, white, brown or green insulator includingone galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,150mm height, 150mm dia for 11000 volts grade complete all as specified and directed. 57 S&F Pin type, porcelain, vitreous, white, brown or green insulator includingone galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33000 volts grade complete all as specified and directed. 58 M & L for Servicing and complete overhauling of VCB 11 KV Indoor type 630 Amps capacityincluding disassembly of operating mechanism parts, well cleaning with petrol & CRC-226, replacing of moving parts, re-assembly, fine setting of mechanism, replacement of unserviceable parts and re-assembly of parts including well cleaning the complete panel board main bus bar, de-carbonizing all joints, bus bar, CTs’ PTs spouts, metal parts and making VCB perfect operation in manual and electric mode including all routine and preventive maintenancecomplete all as specified and directed. 59 Supply and fixing by stringing stretching and strengthening on insulators ACSR conductor of desired size including aluminium binding wire of suitable cross sectional areaincluding joints sleeve for jointing conductors of equal or unequal size and for jumpers connections including treatment of connector and ACSR conductor joints/jumpers with conducting jelly, and taking down of UNSV conductors complete all as specified and directed. 60 Material and labour for tree branches/vegitation cutting around the HT lines and installations from line conductor to tree distance up to 4 mtrs and cutted wood pieces/vegitation materials disposal upto distance not exc 100 mtr at defence landlocation whereas directedand including providing safety eqpts & cutting tools,ladders etc will be own arrangement by the contractor and complete all as specified and directed.Note:- (1) Safetymeasures will be fully responsibleby tenderer (2) During tree /branches/vegitation cutting any damages on OH lines/installation should be reuniform responsible fully by the tenderer with out any extracost.(3) Approximately distance coveredboth side for the HT lines/installatons not exc 100 mtrmeasuredas a one span only 61 Material and labour for paintng of HT pole of any type/size/length and removing from existing pole painting by using wire brush and using with emary paper and cleaning with chemical agents after cleaning of steel tubular pole and GI brackets and cross arms in two coats of red oxide primer and two coats of silver oil painting upto smooth finishiningand paintingto satisfactorly by engr-in-charge and painting work carryout at any height and including marking of pole numers as directed and safety eqpts & tools will be own arrangement and complete all as specified and directed. Note:- Cost of painting materialis deemedto be included in quoted rate only. 62 Supply and fixing in replacement galvanized iron strip of size 32x 6 mm to be fixed on wallor to belaid in ground including taking down from any position and any placescomplete all as specified and directed. 63 Material and labour for fault finding on 11 KV HT cables in trenches of any size and any length with fault detective(fault finding) machine by thumbing method andinjection suitable high voltageproper fault finding equipment and all as testing device instructions and including necessary excavation, returning filling,removing surplus soil,sand, existing bricksetc where find the cable faultycomplete all as specified and directed. 64 Material and labour for scraping of old paint of 33/11KV yard substation (02 Nos bay) steel structure posts by using emery/iron brush and painting with two coats of aluminium to complete 33/11KV substation including entire steel structure upto height of 10 mtr incl aluminium painting of XPM jalli around transformer,spray painting to CT/PT unitscomplete all as specified and directed.Note:- Contractor has to take complete shut down and contractor shall not be provided working periods more than 02 Hrs/day 65 M & L for Scraping of old paint of HT pole 11/12 mtr height without removing accessories and preparationof surfaces for repainting.Repainting the poles with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr above ground level height using synthetic enamel paint .Repainting the remaining Iron parts i.e. cross arms, supporting angles, clamps, GI bkt etc and steel pole above 1.5 mtr height by applying one coat of aluminium paintor PCC pole with snowcem of approved color all as required at site or directed. 66 S & F 100 mm bores of tubes light grade galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cablecomplete all as specified and directed. 67 Supply, fabricating, installation, testing , commissioning and electrically connecting HT bus bar feeder pillar box for 95 Sq.mm Cable and Panel of size 100cm x 110cm x 65 cm,11KV ,factory made , machine pressed , dust and vermin proof ,out door type made with CRCA sheet 3.15 mm thick , HT Feeder Pillar internally and externallyshall bepainted with expoxy powder coating RED paint with 7 tank process for treatment of degreasing, pickling & two coats primer, IP65, before being given the stove epoxy finish. , both side opening in two halves with rubber beading , including Aluminium bus bar of 250 Amp (Each Strip Size 50 x 6mm x Length 800 ) capacity, 4 strip mounted on HT porcelain insulators, HT Danger Plate Provided on Both Side,bus bar chamber and shall be provided with inspection covers , Cubical switch shall have the independent opening panel and shall be mounted on angle iron frame and legs made from angle ironof size 50mm x 50mm x 6mm frame including lifting arrangement and legs duly spray paintedwith two coats of synthetic enamelpaint over a coat of redoxide primer , embeding and grouting in PCC (1:2:4) type B1using 20 mm graded crushed stone aggregate in foundationincluding necessay earth work, including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade comprising, Cable enter with Cable Glands and following accessories including testingcomplete all as specified and directed. 68 M & L for replacement shackle type porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 150mm height, 150mm dia for 11000 volts gradecomplete all as specified and directed. 69 Supply and fixed cable jointing kit for 33 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but95 sqmmcomplete all as specified and directed. 70 Note:- Deduction for Schedule of credit (Sch A Part-II) to be made of ₹201920.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents.
Contract Date: Feb 10, 2026 Contract Value : 28.80 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Jammu And Kashmir View Result →
21.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
22.
Housing Urban and Rular Development #9359483 Technical Bid
Tender For Supply, Installation And Commissioning Of Sophisticated Laboratory Equipment Fixtures With Gds System At Food And Drug Administration, Bkc, Mumbai.- 1 Instrument TableAcid & Chemical Resistant MobileModule :-16 Gauge Front Structure & 20 Gauge Body . Shutter Thickness 25 mm . 2 Nos Cabinet shutter will be in double skin construction and shall be provided with heavy duty, knuckle and barrel type SS hingeskand positive catch arrangement. Modules made up ofTata Galvano 0 Single Pass Skin sheet.Telescopic Hafele Germany Make ( Model No. - HA422.58.335 ). SS 304 Butt Hinges -2 inch 2 mm Thick . Make. Handle : - Aluminium Conceal type . It has an access space for utility . Several no. of electrical connections to fullfill highend requirments . power trench inbuilt and acts aswork top support . The under module shall be fabricated out of heavy gauge special grade Galvanized Iron sheet in weldless construction and shall be finished with pure 8 tank process Epoxy coating for extra ordinary corrosion resistance. Carbon Black Top . Dimesnison 3000mm L x 750mm D x 750 mm H . 2 Sink Unit With Eyewasher Peg Board & Faucet:- 750 mm height lab storage unit havingtwo shutters & a service cutout on the base panel for drainage system .Unit is also having 100mm toe space at bottom, complete unique mobile cabinet with castor wheels at the bottom can be accessible any where .Complete Tata Galvan O furniture is pretreated with 8 tank pickling process further Chemoxy coated by maintaining 70 to 80 micron film thickness. Unit Carrying Components Like PP Hose Pipe with Coupler made from high grade & highly chemical resistant PP material. PP Hose Pipes are available in black color at standard size is 40mm OD with 1 meter long.Brass Casted Faucet , Peg board & Brass Casted Eyewasher Fitting Accessories .T Joints, Brass casted, Elbow Brass Casted, Angle cock , Connector , Module Cutouts Drain Cutouts .Carbon BlackTop 18 MM THICK . 3 Lab Speccilised chairs :-Frame Material – plastic, Adjustable seat height, recline, seat lock, wheels, swivel, armrest, locking mechanism. Size : 49 cm W X 60 cm H, Upholstery type : Cushion/SS 304 4 Head Shower Eye Washer:-Valve: Made from G.I. Powder Coating. Through - Passage Valve which opens automatically when the lever is pushed, and the valve stays open until it is manually closed. Shower Head & Eyewash Bowl: In highly Visible Yellow ABS anti-corrosive plastic. Spray Head Assembly: Two high flow Sprays aerated at low pressure which bathe the eyes and face of the injured person, with automatic anti-dust cover, which operate when the Eye wash is used and it is made of with Brass Pipe. 5 Reagent Rack :-Multi stage multiutility rack Incuding the power trench . And can also hold upto three mobile storages . Top Stage Storage Racks with. Robist construction with easy openable panel . Having two slotted pillars for adjustable rack . fixte below granite complete non-visible screw structure .90 x 280 mm Cross Section Rectangled trench carring electrical & Data wires, holding switch & Sockets . Taper way to avoid wire plug bends MOunted. 6 Antivibration table :- Torsion Dampered Rubber multi Layered inbetween The Granite . Side Panel Covered With internal garanite fulfilled FrameStructure . 14 Gauge Frame Structure .Body Cover Made From Tata Galvano 0 Single Pass Skin sheetin weldless construction and shall be finished with pure 8 tank process Epoxy coating for extra ordinary corrosion resistance. SHOCK Absorbent Height & Gravity Adjustment Levelers .SIZE:- 750 MML X 600MM D X 900 MMH 7 Const. Bypass Bench Type Fume Hood Size :-1500MM L X 950MMD X 2300 H :-General Chemistry Fume Hood Type: Low Constant Volume; ELITE - Series 4 Feet having - Chemical Storage Base Cabinet- PRL Liner - Jet Black Granite WorkTop- Utility Valves = 1no )- Electrical Socket = 4nos 8 ChemicalStorage Unit: - Laboratory Chemicalstorage unit size 1000wx 450dx1950h .Made of 20 gauge Galvan O. PP Lining- 4 Nos Adjustable shelfs inside . Complete unit is pretreated with 8 tank pickling process further Chemoxy coated by maintaining 70 to 80 micron film thickness. Stainless Steel 304 Grade 270 degree openable hinges . . ALong With Volume Control Damper . 1.5 mm PP Lining . 9 Document Storage Cabinets :- Tall Storage Cabinets with MOC; 1 mm thk TATA galvano GPSP sheet with 1 fix and 4 adjustable shelf 2 doors with toughened Consealedglass view panel. complete unit is powder coated with epoxy Powder Coating with Performing 8 Tank Process.Hinges - with 6 nos. of nuckle type of hinges. Hettich/Haffeles Lock 10 Jus Rite Cabinets :- Features two patented, galvanized steel SpillSlope® shelves designed to direct spills to the back and bottom into a 2-in (51-mm) leak-tested sump that meets EPA requirements. Adjustable on 3-in (76-mm) centers, all SpillSlope shelves meet ANSI MH28.1 standards with a 350-lb (159-kg) safe allowable load. Welded shelf hangers interlock with the shelf to offer maximum stability with no flimsy brackets to lose. For replacement shelves, use model 29937.The cabinet also features dual vents with flame arresters, four adjustable self-leveling feet, and a built-in grounding connector. Its durable lead-free epoxy/polyester powder-coat finish provides excellent chemical resistance inside and out, as well as minimizes the effects of corrosion and humidity. 11 Apron Storage Unit: - Laboratory Document storage unit size 1050wx 450dx1950h .SS 304 Material Super Finish & Garin line Buffing . Swing doors perforated down and hinged on SS hinges which is not exposing inside. SS 304 Constrution .Stainless Steel 304 Grade 270 degree openable hinges . 150 mm Center to center distant , C-shaped designed Stainless steel 304 MOC handle, anti rust and 8mm thick diameter in cross section . View panels for modular wall panels with 5 mm Toughened glass with with all accessories like double adhesive tape , silicon sealant and silica gel with installation. Height adjustable levelers M8 bolted 30mm adjustaing height levelers , with a load carrying capacity of 100 kg per leveler. Bolt Head Moulded with Hard Plastic & PP nobe. 12 Open Storage Rack /1000/450/1900:- Stackable Racks With Slottle angle support . Height Adjustable Shelves .SS Nut & Bolts . Color coat on the material i.e. acid, chemical & alkali Resistant. Various shades over more than 100 are available .Rack can be fitted inverted aslo as a form of tray as per user requirement . Shelves have PP lining and 1.5 ft x 1.5 ft PP Trays . Dual Shade colors with Acid Rasistance PP Sheet Pasting . 13 Umbilicals :- Contains Tunnel for Wiring from ceiling to table is zero expose form . Open Box Runner Present In each Dropper for distribution .With Detachable Opening .Distribution board(Cutout onlys as per given sample ) .Highlighted Color Closing for astetic & Access Purpose Smart Nobs for open & Closing . 14 SS CANTEEN TABLE 1200X 900 :- Rubber Bush to Protect The flooring . The Total Construction is Sharpless. Withstand zero Decompositionof Dirt . SS 304 Platform with 100kg/mtr uniformly distributed load . The height of the table is 750 mm and seat is 450 mm totall ergonomical for all people. 15 Compactors(Sections 1000 x 2000 H x 450 D) : - Semi Open Racks Connected in sets of 3 .moved with the wheel mechanism .the Racks are rolled through chanel guide ba.sed on floor.total G.I. Powder Coated With 3 feet Space between the moving racks section.height for 2100mm . Slots on the trays are optional . 16 Spot Extractor :- Polypropelene Pipe Leak Proof Having Suction Capacity of 150-200 cfm . High End Durabale as well as Acid & Chemcial Resistance. It can be rotated 360 degree and dome can be revolved upto 750 mm radius from the last lever . Every joint is adjustable in regards to height and stability . 17 Gas Distribution System :- This includes various gases engage in fumehood activity like , Mixed Air , Nitrogen , Compress Air, vacuum , oxygen , LPG or CO2. This comes wih the monitoring gauge to check the pressure of such gases within limits . As those can be dangerous if not mainained in designated pressure . Also the MOC engage in piping of the gases is strictly SS 316 and Brass for Water . 18 PP FRP Ducting (5 mm ) :- 3mm PP Sheet acid & Chemical Resistance Sheet . PP Rod Welding the two adjacent Surfaces in optained leak proof joints. For making duct pipe . 2mm FRP Ling for Uniform surface , curved joints which reduces the frictional losses as an acid & chemical resistance material . Elbows Turn such as right angel, obtuse angle & Acute angle bends . Flanges Joining of to pipes with flange buy providing gastket/welding along with Nut Bolting . 19 WorK Station L Shaped:- Computer / Sitting desk compact size made for single person eronomicall well designed with one drawer one shutter pedestral . Table Top is MDF Laminated And Base Frame Made of CRCA ERW Pipe Powder Coated . One Legspace on module . 20 Turbo discharge With Foundation : -Casing PP Discgarger. Fan Impeller to Suck high static pressure air. Motor 1440 rpm 2 hpMotor to run the impeller.Fittings Base Frame , M.S. Angle Support Along With The foundation.Wiring Cable to connect Motor from Starter.Starter to Switch On & Off the blower holding the incomming supply .2mm Frp Lining Acid & Chemical Ressistance frp lining inside & Outside Blower .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
23.
Health and Family Welfare #9180461 Technical Bid
Tender For Electrification Work In Construction Of Phc Building At Negarda, Block Shiv, District Barmer. - 1 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR Short point (up to 3 mtr.) 2 Medium point (up to 6 mtr.) 3 Long point(up to 10 mtr.) 4 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR Medium point (up to 6 mtr.) 5 Long point(up to 10 mtr.) 6 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR On board 7 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 8 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 3x 1.5 sq.mm 9 2 x 2.5 sq. mm. + 1x1.5sqmm 10 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 11 4 x 10.0 sq.mm 12 4 x 6.0 sq.mm 13 1 x 2.5 sq.mm 14 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box 6Way(Incomer 8,Sub Incomer2+2+2) 15 Metal door (single phase) IK-09 and IP-43 with Metal end box 16 Way (16+2) 16 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating 17 Four pole MCB (With B/C curve tripping Characteristics) 18 40 A rating Double pole MCB(With B/C curve tripping Characteristics)6 A to 32 A rating 19 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 20 mm 20 25 mm 21 P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 75 mm dia 22 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 5 step fan regulator 2 Module 360 dgree rotating 23 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 24 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 300 mm sweep 25 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 26 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 27 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 225 mm sweep 28 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 25.0 Sq. mm 3.5 core 29 6.0 Sq. mm 2 core 30 Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth 31 Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 32 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 33 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 34 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 35 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 36 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 37 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .17.2 mm thick and 3 Mtr. Long 38 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .8 SWG G.I. ( Hot Dipped) Wire 39 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . LED Street Light fixture with Minimum lumen output 2450 lm 40 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25 mm Dia. 41 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 42 4 pole MCCB With Thermal Magnetic release up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 43 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 44 Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 32 amp, 5 pin + scrapping Earth, 8 Module 46 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Open execution type 63 A 47 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1.5 TR ISEER not less then 3.8 48 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .25 mm 49 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 50 Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia150 mm dia per running inch length 51 Supply, Fixing and testing of following capacity ISO certified company made wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrialplug top making connection etc complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .4 kVA 52 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 53 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Surface Mounting (with extruded alumn. Housing ) Minimum lumen output 1950 lm 54 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1.0 HP, 1-Ø, (10-120)Mtr, (30-12) LPM 55 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .4 kg 56 Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap actionadjustable thermostat , Dual indicating lampsInjected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloyconnection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 15 Ltr. 57 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 pair 58 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 10 Pairs 59 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR RJ-11 telephone jack singleline 60 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 61 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Cat 6, Un-sheilded Information Outlet 62 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Single Aperture 63 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 64 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Modular Patch Panel Loaded with Cat -6 I/O 65 Supply , Installation, Testing and Comissioning ofUnmanaged Switch Plug-and-play - easy setup with no configuration or no software needed, following Port fast ethernet - 8 port 10/100 MBPS auto-negotiation RJ45 ports,IEEE 802.3x flow control ,supports auto-MDI/MDIX, eliminating the need for crossover cables including making connection etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .24 Port 66 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. 67 OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Recessed Mounting Minimum lumen output 4200 lm 68 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord 1 Mtr 69 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 3.5 x 25.0 sq.mm 70 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 71 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 72 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 73 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 74 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 75 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 76 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 77 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 78 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 79 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 80 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 81 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 82 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 83 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Ring type tape wound CT C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 84 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Red/yellow/Green colour 85 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
24.
Public Administrative Department #9157527 Technical Bid
ARC FOR SITC WORK OF VARIOUS TYPES OF LED LIGHTS WITH PHASE WIRE AND OTHER ELECTRICAL MATERIAL - Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .LED Street Light fixture with Minimum lumen output 5600 lm 2 LED Street Light fixture with Minimum lumen output 8700 lm 3 LED Street Light fixture with Minimum lumen output 15000 lm 4 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .40 mm Dia. 5 Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1 X 25 sq. mm. + 1X25 sq. mm. (insulated) 6 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 2.5 sq.mm 7 Supply and fixing of 11 kV pin insulator confirming to IS:731:1971 with latest ammendment on existing bracket including all accessories like MS forged hot dipped GI Pin confirming to IS 2486(Part-I)/1993 & IS:2486 (Part-II)/1989 with latest amendment, and as per latest Discom specs. etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 8 Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discoms specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure A attached with this BSRLT cross arm 1200 mm long with clamp 9 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 10 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 3 pole Power contactors with following AC 3 Rating 250 Amp 11 SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 4 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection, 250 Amp , 50 kA 12 Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Red/yellow/Green colour 13 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . One day reserve (Analog type ) 14 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 100 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
25.
Health and Family Welfare #9100969 Technical Bid
Tender For 5. Supply Installation Testing Commissioning Of Hvac System Work For Construction Of District Hospital In Sheoganj, Rajasthan - A. Air washer comprising of 2nos Pre-Filters. First filter shall be 50mm thick Aluminium wiremesh filter & second filter shall be 50 mm thick MERV-8 synthetic media filter with efficiency 90 % down to 10 microns. Both filters to be placed over the common frame. 4 B. Humidification section comprising of Wet pads 200 mm thick impregnated cellulose paper media ( Celdec pads ) with 2 bend PVC eliminator. The End plates of Pad & Eliminator shall be in SS 304 construction. Also, the inner blank offs of Wet section shall be in SS304 construction. 5 C. Fan Section comprising of belt driven, DIDW Backward curved AMCA certified centrifugal fan with maximum air outlet velocity of 10m/s suitable for required cfm at 50 mm static pressure (Total static of the unit shall be verified by the OEM before the design & supply of the units). Fan & Motor should be mounted over Aluminium channel of suitable thickness and should be isolated from the units bottom panel by means of Spring isolators. 6 D. TEFC High efficiecny IE-3 class motors as required with pulley, belt , Guard 7 E. The unit shall be fabricated with frame work hollow extruded aluminium profile with 0.80 mm preplasticised GSS on outside and 0.80mm 275gsm plain GSS on inside complete with 25 mm thick CFC free PUF insulation of minimum 40 kg/cum density sandwiched in between inner and outer skins. Unit should have MS powder coated legs to give height to units base channel from the floor surface. SS-304 ( 18 g ) Sump, UPVC Internal piping, make up, drain & quick fill and drain connection, Butterfly/Gate valves for pumps, make up, drain & quick fill and drain connections of sump, 2 no. Vertical Pumps of suitable capacity to be placed inside the units housing (external pumps are not acceptable) ,Y strainers and necessary fittings, Concrete Blocks / M S stand, anti vibration pads etc.as required. All as per pre approved by Engineer in charge. 8 20000 CFM 9 15000 CFM 10 SITC of Wall mounting cubical type Starter panel made out of 1.6 mm thick sheet steel powder coated enclosure designed as per Switchgear OEM type -2 coordination chartand suitable for operation of following cfm range Air Washers Blower motor, pumpcomprising of over load protection relay, short circuit & single phasing protection, ON / OFF push buttons, ammeter, voltmeter, indicating lamps, MCB etc. complete in all respect. All as per pre approved by Engineer in charge. 11 20000 CFM 12 15000 CFM 13 P & F of Fire retardent flexible canvass connection made of fibreglass weave having silver grey silicon rubber coating, of height 200 mm with sufficient fold to avoid transmission of vibrationwith GI frame ,Gasket Nut Bolts for air cooling Plants/AHU/FCU etcas required.All as per pre approved by Engineer in charge. 14 Supply , Installation, Testing and Comissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive)& fabricated as perIS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. All as per pre approved by Engineer in charge. 15 0.60mm 16 0.80mm 17 1.00mm 18 Supply , Installation, Testing and Comissioning of site fabricated ducting made from aluminium sheet conforming to IS:737, Grade 31000fabricated as perIS:655 and as per approved drawings & designs including the cost of hangers, supports , angle , expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. All as per pre approved by Engineer in charge. 19 0.60mm 20 0.80mm 21 Supplying, installing, testing and balancing ofextruded Aluminium Powder coated supply/returnGrilles with fixed bars at fronthaving 0 / 15 / 30 / 45 degrees deflection as required. with Flange size 20 mm with rounded edges including fixing with steel screws etc. complete in all respect.All as per pre approved by Engineer in charge. 22 Supplying, installing, testing and balancing of double louvered of extruded Aluminium Powder coated supply/return air grills of various sizes, Each grill shall be with fixed horizontal front bar at 0 deflection and back adjustable vertical louvers, air distribution grid for straightening the air flow through the collar and register including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. 23 Supply air grill with key operated volume control damper 24 Return air grill without volume control damper 25 Supplying, installing, testing and balancing of extruded Aluminium powder coated Air Diffuser and complete with Flush, 20mm flanges with PVC/neoprene gasket, anti – smudge frame and removable inner core to facilitate the adjustable of air control damper, square/round/ rectangular as required.including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. 26 Supply Air Diffuser with Volume Control damper 27 Return Air Diffuser without Volume Control damper 28 Supplying, installing and balancing of extruded Aluminium powder coated fresh air inlet louvers with bird screen & volume control damper fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. 29 Supply , installation, testing & balancing of 20 Gauge G I Damper with brass bushes and 6 pitch multiblade box type galvanised sheet steel construction volume control damper for Ducting and air washers to be provided with suitable links and quadrants for control of volume of air as per specifications complete as required. All as per pre approved by Engineer in charge. 30 Supply and fixing of acoustic lining of ducts withchemically cross link Oxide accetate foam open cell structure Acoustic Insulation with density 30 Kg / Sqm, UV protected and Class O Fire propperty Water Vapour absorption 0.002 gm / Sqcm,including cost of adhesive etc. complete in all respect.All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. 31 15 mm thick 32 25 mm thick 33 Supply and fixingduct insulation with 50 mm thick Expanded Polystyrene Thermocol (ESP) sheet of density 24 kg/cu.m after applying two coats of cold setting adhesive (CPRX Compound) and binding sheet with chicken wire mesh and applying cement mortar plaster (1:4) including primer & painting (suitable for outdoor aplication) matching with building colour or as per direction of Engineer incharge as required. All as per pre approved by Engineer in charge. 34 Supply , Installation, Testing and Comissioning ofInverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and50 hz , single phaseACsupply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 35 1.0 TR ISEER not less then 4.6 36 1.5 TR ISEER not less then 4.6 37 2.0 TR ISEER not less then 4.6 38 SITCof air cooled ducted splittype air conditioning machine with each having a capacity and details as mentioned below suitable for operation on factory chargedR-32/R-410A Green refrigerant comprising ofScroll /rotary type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system,Suitable capacity squirrel cage induction motor with class B insulation suitable for operation on sigle / three phase supply, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers,Microprocessor based control panel complete with accessories, machine isolation / disconnect switch, valves and accessories to inter connect compressor and condender including pressure testing, vacuum.Necessary starters suitable for Indoor & outdoor unit complete with O/L , U/V, phase reversal protection,single phase preventors etc complete as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 39 4 TR 40 5.5 TR 41 8.5 TR 42 Supply , Installation, Testing and Comissioning of Air Cooled Cassette typeAir conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, +/- 10% 50 Hz ,1 /3 phaseACsupply, apable of performing cooling, dehumidification,Air circulation, filteration & ventilation of following capacity with Scroll /rotary/twin rotary compressor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 43 Inverter Type 44 3.0 TR 45 3.8 / 4.0 TR 46 SITC of Interconnecting refrigerantcopper pipe forsplit/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizesas per OEM requirement & specifications including class O Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. 47 Supply, installation, testing and comissioning ofinterconnectingcopperrefrigerant pipingof DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink MarkBrand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified Class O in Fire Propagationas per BS 476 Part 6 including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. All as per pre approved by Engineer in charge. 48 25 mm O.D.,wall thinkness ≥ 1.2mm (insulation – 19 mm thick) 49 22.2 mm O.D., wall thinkness ≥ 1.0mm (insulation – 19 mm thick) 50 19.1 mm O.D., wall thinkness ≥ 1.0mm (insulation – 13 mm thick) 51 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 52 12.7 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 53 9.5 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) 54 Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping withfittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing,support with MS hanger on ceiling or recessed in wallwith chasing & plastering with 6 mmthickclosedcellelastomeric nitrile rubberinsulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 55 20 mm 56 25 mm 57 Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required. 58 1.5 sq.mm x 3 core 59 2.5 sq.mm x 3 core 60 4.0 sq.mm x 3 core 61 Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC.All as per pre approved by Engineer in charge. 62 Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Tr outdoor type of Split/Ductable/Tower AC.All as per pre approved by Engineer in charge. 63 Supply,Installation, Testing & Commissioning of modular type VariableRefrigerantFlow/VariableRefrigerantVolumeaircooled Outdoorunitssuitable for cooling and heating,having100% hermetically sealed inverter type Scroll Compressor(s) withand minimum two compressors along with two Condensing fan,above 14/18 HPmodules,microprocessorbased Controller, Side / top discharge type condensing unit(s), with R-410 A Refrigerant,vibrationisolators,withsuitablefoundationetc. completeasrequired.Theunitshalldelivertheratedcapacityat AHRIConditions andwork evenat 50°C ambient temperature without tripping.The unit shall be suitable to work on 400V +/- 10%, 3Phase,50HzACpowersupply.Theunit shallbefilledwithfirst charge of the refrigerant and ready for use as required. The EER at 100% load with AHRI conditions shall not be less than 3.5 andIncluding OEM supplied Piping connection Kit etc. as required. All as per pre approved by Engineer in charge. 64 Supply, installation, Testing & commissioning of VRV/VRF compatible OEM make AHU KIT including expansion valve and controller for connecting AHU with VRF. 65 Gas charging of VRF/VRV system with R410A refrigerant gas. Before gas charging system shall be flushed with high purity Nitrogen Gas to remove carbon content, dirt particles to make sure that there is no chance of mixing any impurity with Refrigerant Gas. Thereafter System shall be tested with Nitrogen Gas at 1.5 Times of working pressure of R410 Refrigerant Gas to ensure leakproof system. Whole system shall be Vacuumed up to 500-micron level which ensures the zero-moisture content level in piping to ensure better cooling efficiency and long life of the system. All as per pre approved by Engineer in charge. 66 Supply and Installation of Box type EU13 Hepa Filter of 99.997% efficiency down to 0.3 micron particle size installed in zero leakage Aluminium frame as per ISO 14644-1 clean room including sealing and packing material cost like silicon and hardware cost and Labour cost. NABL accredeated/ appropriated lab testing reportswith OEM certificate must submitted to engineer in charge. All as per pre approved by Engineer in charge. 67 150 mm thick 68 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 69 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 70 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 71 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 72 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 73 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 74 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 75 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 76 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. 77 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. 78 Electrolytic grade Aluminium bus bar 6010 grade 79 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. 80 Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 81 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. 82 Ring type tape wound CT 83 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 84 C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA 85 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. 86 Red/yellow/Green colour 87 Blue / white Colour 88 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. 89 4 pole MCCB With Thermal Magnetic release 90 200 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 91 4 pole MCCB With Microprocessor based release with adjustable O/L &S/C setting with Inbuilt Instantaneous and Ground fault Protection. 92 400 Amp , 50 kA 93 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. 94 Shunt Trip Release 95 Under Voltage Release 96 Extended Rotary Handle 97 Spreaders for 250A, 4 Pole MCCB 98 Spreaders for 400A, 4Pole MCCB 99 Phase Barriers up to 630A, 3/4Pole MCCB 100 P & F Earth leakage relay for continuous surveillance of the earth leakage current of Rating 240 VAC at 50/60 Hz, Overload :x2 continuously, x10 for 3 secs as per BS6253, Voltage Tolerance : : - 25% to +10%Operating temp.: : -10 C to +70 C, Setting of trip point : : 0.030, 0.10, 0.30, 0.50, 1.0 ,3.0 ,5.0, 10.0,20.0 & 30.0( User Selectable) with Alarm Relay Output, Trip Relay Output etc. as required. All as per pre approved by Engineer in charge. 101 ELR with 70mm CBCT 102 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. 103 Four pole MCB (With B/C curve tripping Characteristics) 104 40 A rating 105 50/63 A rating 106 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. 107 Four pole 100/300 mA sensitivity 108 40 A rating 109 63 A rating 110 Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 111 3.3 KV,class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) 112 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArmouredCoppercable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withelectrolytic gradeCopper made of copper rodsconfirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 113 10.0 Sq. mm 114 4 core 115 16.0 Sq. mm 116 4 core 117 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapefor following size of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. 118 4 x 10.0 sq.mm 119 4 x 16.0 sq.mm 120 Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. 121 150mm x 50mm x 1.6mm 122 300mm x 62.5mm x 2.0mm 123 450mm x 62.5mm x 2.0mm 124 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 125 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 126 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 127 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 128 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 129 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 130 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. 131 17.2 mm thick and 3 Mtr. Long 132 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. 133 25mm x 3mm G.I. ( Hot Dipped) Strip
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
26.
Banking and Finance #9089883 Technical Bid
Strong Room Door Class B With Accessories Strong Room Door Class B With Accessories , Item , Technical Specification Of Trtl Vault ( Strong Room ) Door ( Class-B ) With Exhaust Fan, Ventilator, V-Cage The Vault ( Strong Room ) Door ( Main Door ) Dimension And Specification Shall Be Strictly Adhering To Is 11188 ( Part-1 ) :2014, The Door Shall Have Bis Label Of Class B Having Torch & Tool Resisting Capacity For Minimum 30 Minutes And Fire Resisting Capacity For Minimum 30 Minutes., The Bidder / Oem Must Possess Valid Bis License To Manufacture And Supply The Aforementioned Trtldoor ( Class B ) , All The Surfaces Of The Door Before Painting Shall Be Thoroughly Degreased And Cleaned Of Rust And Scales Preferably By 12 Tank Pickling Process And Treated Chemically To Prevent From Rusting., The Door Shall Be Painted Inside And Outside With An Anti-Corrosive Primer Followed By Two Undercoats Of Paints And Finally Painted With Quick Drying Paint, Resulting Into Minimum 300 Hrs Of Salt Spray Resistance. ( Attach Certificate / Declaration ) , The Main Door ( Class B ) Shall Consist Of Outer And Inner Mild Steel Plates Conforming To Is 2062:1992 For Plates Up To 20 Mm Thick Strongly Rimmed And Continuously Welded To Form A Single Structure And Tightly Enclosing A Solid Slab Of High Speed Drill Resisting And Oxy Acetylene Torch Resisting Material That Is At Least 50 Mm Thick, Door Frame : The Door Frame And Vestibule Shall Be Welded To One Piece Construction With A Minimum Thickness Of 10 Mm And Shall Grip The Concrete Wall., Rebate : The Rebate Of The Door Frame Shall Be Formed By Mild Steel Sections. The Vertical Rebates Shall Be Riveted Or Welded With The Side Members Of The Door Frame And Shall Conform To Dimensions As Specified By Is 11188., Clenching Mechanism : A Continuous Resilientpacking Shall Be Incorporated In The Frame And A Conpression Mechanism For Clenching The Door Tight Shall Be Provided So As To Protect Against Admission Of Flood Water Or Liquid Explosives. In Locked Position The Door After Clenching Shall Not Have Any Play In The Direction In Which The Door Opens., Thickness Of Door Over Locks : Should Be Of Minimum 90Mm Thickness., The Door Shall Have An Automatic Relocking Device For Each Key Lock Fitted In The Door Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosives Or By Other Means. , Primary Lock Of The Door Shall Have Additional Relocking Device Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosive Or Any Other Means., The Lock Shall Be Dual Control Type And Have At Least 8 Active Levers Of Brass Of Minimum 1.2 Mm Thickness. There Should Not Be Any Dummy ( False ) Levers., The Bidder / Oem Must Be The Original Equipment Manufacturer Of The Locks Used In The Aforementioned Safe. ( Oem Must Give A Written Undertaking On Letterhead And Must Also Give An Noc The Bank For Plant Visit If Needed ) , Lock Case : Should Be Minimum 2 Step Case Construction Covering Entire Jamb Area., The Lock Shall Be Fixed With At Least Four Bolts Of 8 Mm Diameter Such That Any Pressure Applied On The Bolts Either Directly Or Through Handle Of The Door, Is Not Transmitted To The Fixing Screw Of The Lock / Locks. All Working Parts Of The Lock Shall Have Corrosion Resistant Properties Capable Of Withstanding Exposure For 72 H In Standard Salt Spray Test With 5 Percent Salt Solution. , Bolt Work : There Shall Be 6 Locking Bolts Each On The Vertical Edges Of The Door ( Front Edge & Rear Edge ) ., Hinges : Strap Hinges To Be Suitably Bolted To The Door Shultter. The Hinge And Pivot Should Be Such That There Is No Appreciable Friction Or Play For The Movement Of The Door. The Pivots Shall Have Arrangements For Lubrication And A Height Adjustment Bold Is To Be Provided To Adjust Height Of Door Shutter. , Grill Gate ( Inside ) : Ventilating Grill Gate Shall Be Made Of Mild Steel Angles, Plates Or Channels With Mild Steel Rods Welded In A Rigid Frame. The Grill Gate Shall Be Hinged In Strong Room Door Frame Such That It Opens Inside. An Unpickable Dual Control Locking Device Capable Of Being Operated From Both The Sides Of The Door Shall Be Fitted In The Grill Gate. , Emergency Door : The General Specifications Of Emergency Door Shall Remain As For The Main Door Except For Bolt Work. For Bolt Work, There Shall Be 3 Locking Bolts Each On The Vertical Edges Of The Emergency Door ( Front Edge & Rear Edge ) ., Limit Switch / Lighting Control: Vault Lighting Control Shall Be Fitted On The Main Door To Automatically Control The Electric Supply To The Vault.
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Uttar Pradesh View Result →
27.
Housing Urban and Rular Development #9084402 Technical Bid
Tender For Highmast Light And 6 Nos Road Light (E/W) In Construction Of Various Develpments Works At Gurudwara Budha Johad Distt Sri Ganganagar (Ew) Highmast Light And 6 Nos Road Light(E/W) In Construction Of Various Develpments Works At Gurudwara Budha Johad Distt Ri Ganganagar (Ew), 1 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 2 Poles with Octagonal Cross Section 3 7 Mtr. 4 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 5 Single arm overhang 6 Double arm overhang 7 Providing and Laying RCC Foundation for Octagonal/ Conical Street Light poles, High mast Poles as per Drawing attach at TableP-4with Following Procedure& All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 8 A) Excavation of Pit for Foundation Size upto required depth from Ground level 9 B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete. 10 C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness 11 D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete. 12 E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal 13 F) Providing & Fixing of 2 no. Required SizePLB HDPE Pipe& Foundation Bolt with template as per OEM Recommendations. 14 G) Providing and LayingReinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. 15 H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. 16 Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. 17 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 18 25.0 Sq. mm 19 3.5 core 20 6.0 Sq. mm 21 4 core 22 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 23 4 pole MCCB With Thermal Magnetic release 24 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 25 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 26 3x 1.5 sq.mm 27 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 28 Red/yellow/Green colour 29 Blue / white Colour 30 Providing & Fixing of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 31 Providing & Fixing ofAC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 32 3 pole Power contactorswith following AC 3 Rating 33 40 Amp 34 Providing & Fixing ofthermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 35 24 to 40 Amp 36 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 37 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 38 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 39 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 40 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 41 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 42 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 43 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 44 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 45 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 46 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 47 25mm x 3mm G.I. ( Hot Dipped) Strip 48 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 49 10 SWG G.I. ( Hot Dipped) Wire 50 Supply installation testing & Commissioning ofhigh mast lighting system (as per PLG 07of ILP UKtechinical report no7 of ILE UK /IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstructionlights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly ) foundation bolt, torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required on Existing Foundation.(See table P - 03 for specs.) OEM Must haveType test certificate for wind tunnel test .All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 51 20.0 Mtr Hm (in 2 section) suitable for 12 No. Luminaries 52 Providing & Fixing ofIK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles,of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R numberhaving efficiency more than 85 % and in compliance to BIS certified and Trade markcertificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K±355K.Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 53 High Power LED Flood Light Minimum lumen output 37500 lm 54 High Power LED Flood Light Minimum lumen output 18650 lm 55 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 56 LED Street Light fixture with Minimum lumen output 11225 lm 57 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 58 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 59 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 60 Earth work in excavation/ by mechanical means (Hydraulic Excavator) / Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: 61 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 62 Triple pole MCB(With B/C curve trippingCharacteristics) 63 40 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
28.
Banking and Finance #9070149 Technical Bid
Strong Room Door Class B With Accessories Strong Room Door Class B With Accessories , Item , Technical Specification Of Trtl Vault (Strong Room) Door (Class-B) With Exhaust Fan, Ventilator, V-Cage The Vault (Strong Room) Door (Main Door) Dimension And Specification Shall Be Strictly Adhering To Is 11188 (Part-1):2014, The Door Shall Have Bis Label Of Class B Having Torch & Tool Resisting Capacity For Minimum 30 Minutes And Fire Resisting Capacity For Minimum 30 Minutes.,The Bidder/Oem Must Possess Valid Bis License To Manufacture And Supply The Aforementioned Trtldoor (Class B),All The Surfaces Of The Door Before Painting Shall Be Thoroughly Degreased And Cleaned Of Rust And Scales Preferably By 12 Tank Pickling Process And Treated Chemically To Prevent From Rusting., The Door Shall Be Painted Inside And Outside With An Anti-Corrosive Primer Followed By Two Undercoats Of Paints And Finally Painted With Quick Drying Paint, Resulting Into Minimum 300 Hrs Of Salt Spray Resistance. (Attach Certificate/Declaration), The Main Door (Class B) Shall Consist Of Outer And Inner Mild Steel Plates Conforming To Is 2062:1992 For Plates Up To 20 Mm Thick Strongly Rimmed And Continuously Welded To Form A Single Structure And Tightly Enclosing A Solid Slab Of High Speed Drill Resisting And Oxy Acetylene Torch Resisting Material That Is At Least 50 Mm Thick, Door Frame : The Door Frame And Vestibule Shall Be Welded To One Piece Construction With A Minimum Thickness Of 10 Mm And Shall Grip The Concrete Wall., Rebate : The Rebate Of The Door Frame Shall Be Formed By Mild Steel Sections. The Vertical Rebates Shall Be Riveted Or Welded With The Side Members Of The Door Frame And Shall Conform To Dimensions As Specified By Is 11188., Clenching Mechanism : A Continuous Resilientpacking Shall Be Incorporated In The Frame And A Conpression Mechanism For Clenching The Door Tight Shall Be Provided So As To Protect Against Admission Of Flood Water Or Liquid Explosives. In Locked Position The Door After Clenching Shall Not Have Any Play In The Direction In Which The Door Opens., Thickness Of Door Over Locks : Should Be Of Minimum 90Mm Thickness., The Door Shall Have An Automatic Relocking Device For Each Key Lock Fitted In The Door Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosives Or By Other Means. , Primary Lock Of The Door Shall Have Additional Relocking Device Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosive Or Any Other Means., The Lock Shall Be Dual Control Type And Have At Least 8 Active Levers Of Brass Of Minimum 1.2 Mm Thickness. There Should Not Be Any Dummy (False) Levers., The Bidder/Oem Must Be The Original Equipment Manufacturer Of The Locks Used In The Aforementioned Safe. (Oem Must Give A Written Undertaking On Letterhead And Must Also Give An Noc The Bank For Plant Visit If Needed), Lock Case : Should Be Minimum 2 Step Case Construction Covering Entire Jamb Area., The Lock Shall Be Fixed With At Least Four Bolts Of 8 Mm Diameter Such That Any Pressure Applied On The Bolts Either Directly Or Through Handle Of The Door, Is Not Transmitted To The Fixing Screw Of The Lock/Locks. All Working Parts Of The Lock Shall Have Corrosion Resistant Properties Capable Of Withstanding Exposure For 72 H In Standard Salt Spray Test With 5 Percent Salt Solution. , Bolt Work : There Shall Be 6 Locking Bolts Each On The Vertical Edges Of The Door (Front Edge & Rear Edge).,Hinges : Strap Hinges To Be Suitably Bolted To The Door Shultter. The Hinge And Pivot Should Be Such That There Is No Appreciable Friction Or Play For The Movement Of The Door. The Pivots Shall Have Arrangements For Lubrication And A Height Adjustment Bold Is To Be Provided To Adjust Height Of Door Shutter. ,Grill Gate (Inside) : Ventilating Grill Gate Shall Be Made Of Mild Steel Angles, Plates Or Channels With Mild Steel Rods Welded In A Rigid Frame. The Grill Gate Shall Be Hinged In Strong Room Door Frame Such That It Opens Inside. An Unpickable Dual Control Locking Device Capable Of Being Operated From Both The Sides Of The Door Shall Be Fitted In The Grill Gate. , Emergency Door : The General Specifications Of Emergency Door Shall Remain As For The Main Door Except For Bolt Work. For Bolt Work, There Shall Be 3 Locking Bolts Each On The Vertical Edges Of The Emergency Door (Front Edge & Rear Edge)., Limit Switch/Lighting Control: Vault Lighting Control Shall Be Fitted On The Main Door To Automatically Control The Electric Supply To The Vault.
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 6
Uttar Pradesh View Result →
29.
Tourism #8521150 AOC
Tender For Construction Of Shri Khema Baba Panorama, Baytu, Balotra (Raj.) - Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils 2 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). 3 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix. 4 Add extra for providing richer mixes respectively at all floor levelsProviding M-25 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix. 5 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 6 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 7 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 8 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Columns, pillars, posts and struts etc. 9 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. 10 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 11 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 12 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 13 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 14 Random rubble dry stone Kharanja (soling) under floor. 15 Carriage of MaterialsBuilding Rubbish Stone metal (Grit and ballast etc.)For 10 Km. 16 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr. : All kinds of soil 17 Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in :Cement Mortar 1:5 ( 1-Cement : 5-Sand). Wall upto 30cm. and less thickness. 18 Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 : Cement mortar 1 : 4 (1 cement : 4 coarse sand) 19 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :25mm thick. 20 Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish :20mm thick. 21 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 22 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 23 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 24 Providing & laying Chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of C.M. 1:4 :. Medium shade using approximately 50% white cement and 50% ordinary cement. 25 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Jalore (P-white / S-white/ Rosy Pink colour).Above 3601 Cm2 Slabs 26 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Marble work Full Edge moulding 27 P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 1200 mm 28 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 29 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A:.35 mm thick .Decorative teak veneer both side 30 Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 31 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester mattconsisting of a coat of bitumen primer for bitumen membran @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane.3 mm thick 32 Grading roof for water proofing treatment withwater proffing compoundCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 33 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 34 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 35 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 36 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:. Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 37 Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred weldedand grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge 38 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile B 39 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 40 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 41 Supplying and fixing 7 to 8 cm thick soorsagar stone chajja in slope (3 lines fine dressed)including cutting & moulding weather dripped (both sides dressed) 42 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR, Medium point (up to 6 mtr.) 43 Long point(up to 10 mtr..) 44 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR, On board 45 Long point(up to 10 mtr..) 46 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 47 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR. 25 mm 48 32 mm 49 20 mm 50 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq. mm. + 1x1.5sqmm 51 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 52 4 x 6.0 sq.mm(Panel To DB) 53 4 x 10.0 sq.mm(Panel To DB) 54 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 5 step fan regulator 2 Module 360 dgree rotating 55 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp. 2 Module Socket 56 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Module 57 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4/5 Module 58 RJ-11 telephone jack singleline 59 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1/2 Module 60 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1-2 Module 61 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 pair 62 10 pair 63 P & F Krone module with base framein the recess / surface made out of 1.2 mm thicksheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 10 Pairs 64 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR. Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box. 6 Way (Incomer 8,Sub Incomer2+2+2) 65 12 Way(Incomer 8,Sub Incomer2+2+2) 66 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 67 Four pole MCB (With B/C curve tripping Characteristics) 50/63 A rating 68 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Two pole 100/300mA sensitivity 6A-32 A rating 69 40 A rating 70 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 71 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 72 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 225 mm sweep 73 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 74 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 75 Providing & Fixing of IP20 SMD Mid Power LED batten with integratedbox (min.1200mmx40mmx60mm including reflector) with replacable driverfixture made from Powder coated Extruded aluminiumhousing ,Min. lumen output 4400 lm,System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 4.0 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 76 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products / work, refer Annexure A attached with this BSR . Surface Mounting (with extruded alumn. Housing ). Minimum lumen output 1950 lm 77 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 18/20 Watt 78 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 79 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 80 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Red/yellow/Green colour 81 Blue colour 82 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 83 Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms) 84 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Three phase Ammeterwith Inbuilt Selector Switch 85 Three phase Voltmeter with Inbuilt Selector Switch 86 Providing & Fixing of selector switch of 10 A for voltmeterusing high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Voltage Between Phases with OFF ( 4 Position ) 87 Providing & Fixing of CT linked selector switch of 10 AforAmpere meter (4 position )using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc.as required .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 88 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 3 pole MCCB With Thermal Magnetic release 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 89 4 pole MCCB With Thermal Magnetic release. 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 90 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 91 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 92 50/63 A rating 93 Providing & Fixing of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 Providing & Fixing ofAC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 pole Power contactorswith following AC 1 Rating 25/32 Amp. 95 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4.0 Sq. mm 4 core 96 6.0 Sq. mm 4 core 97 25.0 Sq.mm3.5 core 98 150.0 Sq. mm 3.5 core 99 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapefor following size of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .4 x 4.0 sq.mm 100 4 x 6.0 sq.mm 101 4 x 25.0 sq.mm 102 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 3.5 x 150.0 sq.mm 103 Providing and laying Non Pressure NP-3 classR.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) etc. as required. (Excavation of Earth& Back filling with compaction is to be Paid Extra). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 mm Dia. 104 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :-(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole(b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25 mm thick and 3 Mtr. Long 105 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 5mm copper strip 106 25mm x 6mm G.I. ( Hot Dipped) Strip 107 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .8 SWG G.I. ( Hot Dipped) Wire 108 Providing & Fixing of IK08IP65 protected Top/Bottom mounted LED Post top Luminaire made of single piece constructionpowder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser andAluminium anodised with sand blast reflector. The System level Luminous efficacy ≥100 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N)and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current <750mA.Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Minimum lumen output 4500 lm Post top Luminarie 109 Supply and erection of PU coated , 6 to 7 mm thick Glass / FibreReinforced Pole (GRP /FRP) made by CNC filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass content. designed to withstand the maximum wind speed as per IS 875,and Tested for deflection not more than 15% length of pole as per ASTM D 4923, The pole should be in one piece and tapered round in shape, pole shafts shall be providedwith FRP Anchor with suitable MS cated Base with provision for fixing 4 no. foundation bolts( Including cost of Foundation Bolt),ThePole shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension on Existing cement concrete foundation. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 3 Mtr. Long, Top/ Bottom OD Dia 89/126mm ± 2mm approx. With Base250X250 X 10mm 110 Single arm overhang 111 Providing & Fixing of IK10IP65 protected 600 mm height LED Bollard Luminarie with base platemade of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N)and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintainedLight output in Cool white or Warm White Colour as per engineers choice. driver current <750mA.Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Minimum lumen output 980 lm Bollard 112 Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler withhermeticallysealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick)and tank (0.5 mm thick) , stainless steel water tray,minimum two nosBrass Chrome plated faucets and suitable drainage system complete in all respect with requiredheight MS fabricated and Painted Angle iron frame( Cost of frame to be paid Extra )complete in all respect of the following capacity.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs 113 P & F Indian type white glazed vitreous china Ist quality W.C. orissa pan (IS:2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor :Size 580x440 mm. 114 P & F European type white glazed vitreous china Ist quality Double symphonic W.C. (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor. 115 P & F water closet Seat Covers with brass hinges completeIS 2548-1996 Solid PVC (ISI marked) grade-I White for EWC.: 116 P&F C.P. lugs for toilet seat cover 117 P & F Ist quality WVC Urinal (IS:2556 mark) with 25 mm dia G.I. waste pipe, dome couplings, concealed iron brackets or screws etc. complete. Flat Back (large) or half stall size 610x44x80mm 118 P & F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm. IS 2556 (Part VI Sec.4)-1995. Makrana II quality marble having light spots. 119 P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : PVC with CP brass long band as per IS:7231 120 P & F Flush Pipe of approved make with complete fittings for high level flushing cistern: PVC exposed (heavy) 32mm. 121 P&FC.P.brassUrinalFlushPipeset complete with flanged brackets of approved make. For 1 Urinal 122 P & F C.P. brass Urinal Spreader for stall urinal of approved make. 123 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall :Size 610 mm x 510 mm 124 P&F Soap dish or tray of approved quality/ make.C.P. brass heavy and superior quality 125 P&F looking mirrors with PVC frame of approved ISI Size make. 500x400mm 126 P&F Jet spray for water closet with C.P. copper tube flange of approved make 127 Providing and fiixng C.P. flange for 15mm dia taps 128 P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superior quality and approved make:C.P. Pillar cock, Swan-neck with casted spout, 15mm nominal bore. 129 P & F Bib Cock (IS:8931 Mark) Superior quality of approved make :C.P. Brass bib cock, 15 mm nominal bore. 130 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 131 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt. Not less than 300 gm,15mm. 132 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15 mm Brass (IS:8931 marked). 133 P & F 15 mm. Dia Connection pipe of approved quality/make:C.P. Brass Pipe with CP Brass nuts upto length 450 mm. 134 P & F Full-way valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 32 mm nominal bore. 135 P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design.500 litres capacity. 136 Hoisting Charges for each floor : 137 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 20mm dia 138 25mm dia 139 32mm dia 140 P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant 110mm dia 141 160mm dia 142 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:110mm dia Coupler 143 Plain Tee 144 Door Tee 145 Door Y 146 Bend 45 147 Bend 87.5 148 Door Bend (top side) 149 Door bend (left &right) 150 Vent Cowel 151 Door Cap 152 Pipe clip 153 WC connector with lipring 154 WC connector bent type 155 Plain floor trap 156 P-Trap 157 S-Trap 158 Gully Trap 159 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design : Depth up to 1.5 M 160 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 300 X 300 mm depth upto 0.5 MCement cover with frame. 161 Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering,jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth worketc . complete including disposal of surplus earth within a lead of 50 mtr .Inner dia90 Cm & 10 to 12 Mtr deep. 162 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 gradeC.C floor &RCC slab covering with M15 grade c.c. floor,50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-Size 400 x140x150 cm.(for 50 users)with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect. 163 Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete : 450mm dia Internal 164 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping. 200 mm nominal bore 165 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 150 mm Nominal Bore. 166 Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm 167 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thickness. Diameter 900 mm 168 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 169 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 170 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voidsSize 9 to 12 mm 171 Size 3 to 5 mm 172 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 173 SITC ofDewatering Submersible Motor Pump set, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with SS Impellor, body, shaft, mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1.0 HP, 3-Ø, (5 - 12)Mtr, (333 - 95) LPM
Contract Date: Dec 26, 2025 Contract Value : 2.93 Crore
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : 7.79 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 20
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 1.80 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 17
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 37.50 Lakh
Boards / Undertakings / PSU No of Bidders 4
34.
Petroleum and Natural Gas #7673113 AOC
Tender For Various Civil Works In Gail, Gaon Township; 1 SITE DEVELOPMENT & EARTH WORK 2 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 3 All kinds of soil 4 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. 5 All kinds of soil 6 Earth work in excavation from borrow pit by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) for backfilling purpose including getting out and transporting the excavated soil from the borrow pit to the site within a radius of 5km, as directed by Engineer-in-charge. 7 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soilleads upto alldistance within township at designated spots as directed by Enginner-in-charge 8 Pipes, cables etc, not exceeding 80 mm dia. (All kinds of soil ) 9 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (All kinds of soil ) 10 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm (All kinds of soil ) 11 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 12 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 13 CONCRETE WORK 14 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 15 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 16 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 17 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). 18 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 19 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 20 Neat Cement Punning 21 RCC WORK 22 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -All work up to plinth level : 23 1 :1.5:3 (1 cement : 1.5 coarse sand (zone-Ill} derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 24 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -All work up to plinth level : 25 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 26 Reinforced cement concrete work in roof beams, suspended floors, roofs Reinforced cement concrete work in roof beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 27 Providing, hoisting and fixing upto and above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands,copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 28 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). 29 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 30 Thermo-Mechanically Treated bars of grade Fe-500D or more. 31 Centering and shuttering including strutting, propping etc. and removal of form for 32 Foundations, footings, bases of columns, etc. for mass concrete 33 Suspended floors, roofs, landings, balconies,coaping and access platform 34 Lintels, beams, plinth beams, girders, bressumers and cantilevers 35 Columns,pedastel, Pillars, Piers, Abutments, Posts and Struts 36 Stairs, (excluding landings) except spiral-staircases 37 BRICK WORK 38 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 39 Cement mortar 1 :4 (1 cement : 4 coarse sand) 40 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 41 Cement mortar 1 :4 (1 cement : 4 coarse sand) 42 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : 43 Cement mortar 1:4 (1 cement : 4 coarse sand) 44 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floorV level. 45 Cement mortar 1:4 (1 cement : 4 coarse sand) 46 15 mm cement plaster of mix: (up to 10 meter height from ground level & including making grooves and scaffolding etc. complete) 47 1:4 (1 cement: 4 coarse sand) 48 12 mm cement plaster of mix : (up to 10 meter height from ground level & including scaffolding) 49 1:4 (1 cement: 4 coarse sand) 50 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.( including scaffolding) 51 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 52 Two or more coats on new work (including wood putty and primer work) 53 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (1000kg=15sqm) 54 Wall painting with premium acrylic emulsion paint of interior grade,having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying priming coats wherever required to achieve even shade and colour.( including scaffolding ) 55 New work (two or more coats) over and including water thinnable priming coat with cement primer having voc content less than 50 grame/liter 56 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:(including scaffolding) 57 New work (Two or more coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 liter /10 sqm) 58 BRICK WORK 59 Providing and laying Ceramic anti-skidfloor tiles 300x300 mm as directed by EIC (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand). Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. Ceramic tile of size 300x300 mm matt finish/anti skid as approved by Engineer-in-charge. 60 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 61 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 62 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, bathroom corner shelf,vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 63 Granite stone slab of colour black, Cherry/Ruby red (Area of slab upto 0.50 sqm) 64 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 65 Double charge vitrified tile polished finish of size 66 Size of Tile 600 x 600 mm 67 Providing and laying Vitrified tiles in different sizes {thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc complete. 68 Size of Tile 600x600 mm 69 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps,dados,bathroom,kitchen wall over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Digital ceramic tile of size 300x600/300x450 mm as approved by Engineer-in-charge. 70 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1 :4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile as required at site of all colours and shades. 71 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, door/window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour, size and shade 72 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 73 25 mm thick 74 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 75 STRUCTURAL STEEL 76 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 77 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 78 Hot finished welded type tubes 79 Providing and fixing bolts including nuts and washers complete. 80 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases gratings, frames, guard bar, ladder, railings, brackets, gates and similar work including use of chequered plate wherever required, all complete. 81 FRAME & VENTILATIONWORK 82 Providing and fixing door frame fabricated from sections roll formed out of 1.2mm thick galvanized steel (Base steel as per IS 513) with zinc of 120 gms/sq.mtr, Powder Coated with pure polyester powder paint up to 50-60 microns thick. The overall size of the section should be 105x60mm with rebate of 37mm for shutter for single rebate door frame. The frame section should be cut to length and metre joined with corner brackets made of CRCA electroplated.The frame should be provided with (a) 4 Nos. of M.S. powder coated 4” Butt hinges of 2mm thickness welded to the frame. (b) 6 Nos. of 1.2mm thick CRCA electroplated stiffeners should be welded to frame. (c) 6 Nos. of 8” M.S. hold fasts with split end tail welded to stiffener plates. (d) One no. aldrop receiver. All welded places should be treated with protective coat of zinc rich primer.The entire frame should be provided with a coat of etched primer and powder coated with pure polyester powder up to 50-60 microns and as per direction of EIC : Door Frames Single Rebate 105mm x 60 mm 83 Providing & fixing Windows/ ventilators (double shutter windows- Glazed shutter, Mesh shutter) fabricated from roll framed sections made of Galvanized steel Colour coated/ powder coated (base steel as per IS 513 D quality Galvanized as per IS 277 with zinc of 120 gms/sqm) with total coated thickness of 0.6mm. Coated sections should be with Primer coat of Epoxy Primer of 5-7 microns thick, finish painted with Polyester paint of 12-16 microns thick or Powder Coated with pure Polyester up to 50-60 microns thick. Window Frame should be fixed to brick/ concrete masonry by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frame. Each Glazed Shutter and Mesh shutter should be provided with SS Pivot Hinges, Handle , Stay, tower bolts etc. but this item is excluding the cost of infills like Glass panes, wire mesh. Sections for Frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12mm x 12mm, and Section for Fly Mesh should be of 40mm x 20mm. Overall window area shall be measured for this item for payment which will include any fixed portion, glazed shutter, fly mesh shutter, etc. 84 Providing & fixing frosted /plain glass panes with EPDMand glazing clips in steel doors, windows, ventilator,clerestory windows, all complete with :5 mm thick plain glass panes. 85 Providing and fixing 10 mm MS square guard bar grill at a maximum gap of 100 mm or less with 12mm outer flat as per direction of EIC 86 WOOD WORK 87 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 88 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 89 Providing and fixing aluminium sliding door bolts, ISI marked anodised/Powder coated (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 90 250 X 16 mm 91 Providing and fixing aluminium tower bolts, ISI marked, anodised/Powder coated (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 92 250 x 10mm 93 200 x 10mm 94 Aluminium handleProviding and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 95 100 mm 96 WATER PROOFING WORK 97 Providing and applying two coats of waterproof coating on roofwith liquid applied Elastomeric roof coating based on a hybrid polyurethane technologyincluding single coat of water-based primer composed of acrylic emulsion polymermeeting the standards of ASTM D 1227-87, one layer of 45 GSM glass fiber mesh ,surface preparation, filling of cracks with crack repair putty and surface repair with Polymer modified mortar all comoplete as per direction of EIC. The application rate of the chemicals will be as per defined in the product catalogue. (The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.) 98 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) 99 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 100 In 75x75 mm deep chase 101 (II) PLUMBINGWORKS 102 (A)Fixing,testing and commissioning of sanitary fixtures & cp fittings including all accessories (ISI-marked,sample to be approved from EIC). The contrcator rates to include for supply of all sanitary fixtures & CP fittings including fixing/supporting accessories like WC pan connectors, nut, bolts, screws, nipple, hangers, bottel traps,rubber buffers,CI or MS brackets,anchor fastners, sealents, washers, adhesives, flanges, plumbers tap, white cement,masking tap (if required for protection ), clamps, m.s angle for support etc which are required for successful installation of fixtures/fittings including steel shuttering in a neat workman like manner to satisfaction of EIC.(B) Rates are inclusive of providing,fixing,testing, and commissioning of sanitary fixtures & cp fitting with all accessories at all the height,depth and locations within the township area. (C) Important note :- Please go through approved list of makes before quoting rates. 103 (II) PLUMBINGWORKS 104 Providing and fixing on wall face, shunken,roof portion unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes including all fittings like bend, T, Y, collar,clamp,shoe,coupler, Nahani trap and any other type of fitting of required degree with access door as required, insertion rubber washer 3 mm thick, including fixingthe pipe with clamps at 1 m spacingin walls etc complete including testing.(All measurement will be in running meter along the center line of pipe) 105 75 mm diameter (waste pipe) 106 110 mm diameter (rain water pipe) 107 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) sdr 11 pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases,nipple fixing and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed or exposed work, including cutting chases and making good the walls, trenching and refilling etc. 108 20 mm nominal dia Pipes 109 25 mm nominal dia Pipes 110 32 mm nominal dia Pipes 111 Making arrangment for connection of water supply froom the existing downpipe available in shafts/roof including T and valve. 112 Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c making good the walls including trenching and refilling and painting with anti corrosive bitumastic paint, etc. 113 25 mm dia nominal bore 114 32 mm dia nominal bore 115 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting, threading, trenching and refilling the pipe etc. complete : 116 25 to 40 mm nominal bore 117 50 to 80 mm nominal bore 118 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 119 20 mm nominal bore 120 25 mm nominal bore 121 32 mm nominal bore 122 Providing and laying non pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 123 150mm dia RCC pipe 124 250mm dia RCC pipe 125 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 126 Providing and fixing of Brass Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with plastic ball approved by EIC). 127 20 mm nominal bore 128 EXTERNAL SEWER CONNECTION 129 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 130 150 x 100 mm size P type with FPS 1st Class bricks. 131 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 132 Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : 133 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 134 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 135 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 136 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 137 MakingHunches in Sewer chamber including neat cement punning 138 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 139 For pipes 100 to 250 mm diameter 140 For pipes 250 to 300 mm diameter 141 SANITARY & CP FITTINGS AND FIXTURES 142 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 143 W.C. pan with ISI marked white solid plastic seat and lid 144 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 145 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 146 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required including CP Bottle trap, push cock/angle valve as per direction of EIC. 147 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 148 15 mm nominal bore 149 Providing & fixing health faucet ofHandshower (Health Faucet) with rubbit cleaning system 8mm Dia, 1.25 Meter Long CP coated Flexible Tube and Wall Hook. 150 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. 151 Providing and fixing chrom finish soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms. 152 Providing & fixing of Central hole Basin mixer w/o popup waste system with 2 nos 450 mm long braided hose . 153 Providing and fixing White Vitreous China Wash basin size 560 mm x 415x200 mm with C.I. brackets, 32 mm C.P. brass waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. 154 Bottle trap 32mm size with 300mm & 190 mm long wall connection pipes & wall flange , weighing not less than 260 gms 155 Providing and fixing C.P. brass angle valve for basin mixer and geyser points, cistern wall flange including weighing not less than 350 gms of approved quality conforming to IS:8931 156 15mm nominal bore 157 Providing and fixing ss grating of approved quality and colour 158 Circular type 100 mm nominal dia 159 Providing and fixing 600x450 mm beveled edge looking mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 160 MISCELLANEOUS ITEMS 161 Supply & Fixing of Pre-painted coloured Trapezoidal profiled sheeting 1000-1020 mm cover width, 28 -30 mm high crests manufactured out of 0.50 mm TCT hi-tensile pre-painted Zincalume /Galvalume steel (AZ-150 gsm. Aluminium #Zinc alloy metallic coating of total both sides 550 Mpa yield stress as per AS-1397). Colour/ Exterior coat of SMP (Silicon Modified Polyester) / BHP XRW paint system, 20 micron top coat applied over 5 micron primer and a 5 micron polyester back coat applied over 5 microns primer OR equivalent coating/painting. The sheet shall have wide pans with stiffening ribs for effective water shedding and special male/female ends with full return legs on side laps for purlin support. The male end of the sheet shall have anti-capillary flute at side laps to prevent leakages. The sheet shall be fixed by means of Galvanised self-drilling self tapping fasteners (12-14x55 with EPDM seals). The sheet shall be supplied in lengths maximum upto 6-12 Mtrs long to suit site dimensions. The scope includes all sealing of joint, curves, edges or other accessories with silicon sealant. The bidder may consider clip lock system instead of self drilling screw system without any change in specification, rates and terms and conditions of the work. The work will include cost of all labour, equipments, materials, submission of shop drawing, cost of consumables, fasteners/clip lock, washers etc. The work is to be carried out directly as per specifications and direction of engineer in charge and the manufacturer. 162 Supply & Fixing of Pre-painted coloured Trapezoidal profiled / PLAIN/ CURVED & PROFILED sheeting in ridges, curved surface, North light Curve, Apron Piece Gutter etc., manufactured out of 0.50 mm TCT hi-tensile pre-painted Zincalume /Galvalume steel (AZ-150 gsm. Aluminium #Zinc alloy metallic coating of total both sides 550 Mpa yield stress as per AS-1397). Colour / Exterior coat of SMP (Silicon Modified Polyester) / BHP XRW paint system, 20 micron top coat applied over 5 micron primer and a 5 micron polyester back coat applied over 5 microns primer OR equivalent coating/painting. The sheet shall be fixed by means of Galvanised self-drilling self tapping fasteners (12-14x55 with EPDM seals). The sheet shall be supplied in lengths maximum upto 6-12 Mtrs long to suit site dimensions. The scope includes all sealing of joint, curves , edges or other accessories with silicon sealant. The bidder may consider CLIPLOCK system instead of self drilling screw system without any change in specification, rates and terms and conditions of the work. The work will include cost of all labour, equipments, materials, submission of shop drawing, cost of consumables, fasteners/clip lock, washers etc. The work is to be carried out directly as per specifications and direction of engineer in charge and the manufacturer. 163 Supplying and fixing rolling shutters of approved make, made of required size G.I. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. 164 80x0.90 mm G.I. laths with 0.90 mm thick top cover 165 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture of approved make in the ratio defined in the product catalogue to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturers specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R2010 i.e. by reducing permeability of concrete by more than 90%,compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 166 Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.(Upto and including 12mm dia.) 167 Providing and applying a SBR based bonding coat meeting theBS 6319 part 2:1983 & ASTM C 190-85 standards of approved make constructions cemical to the existing dismantled / cleaned surface in the ratio of cement : chemical as defined in the product catalogue. 168 Providing and fixing 24 gauge size galvanised chicken wire mesh of approved width at junctions of concrete and brick work and other locations called for including necessary laps and U shape galvanised wire nails. 169 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. The aluminum section shall be smooth, rust free, straight and fabrication shall be done from factory with all joints mitered/crimped, outer frame, mullions and shutter frames jointed with heavy duty aluminum angles/cleats and SS Screws including providing masking tapes on the profiles for safety against external scratches at site (protection tape to be removed only at the time of handing over as per the instructions of Engineer-in-charge).Appropriate profile of EPDM gaskets shall be inserted between aluminum frames/ beadings and glass both inside and outside to make the laminated board tight. Glazing clips, EPDM Gaskets shall be used for sealing. The silicon sealant of approved make to be used wherever required for weather proofing. The laminated board to be used shall be 12 mm thick prelaminated particle board with decorative lamination in both sides flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll. 170 P&FChain link fencingof 10 SWG guage with 50x50 mm diamond shape. Chain link GI hot dipped, rates are inclusive of 5 rows of strainer GI 8 SWG which to be fixed fixed with chain link properly by U clamps if required including taking out the old damaged fencing wherever applicable and stacking the same as directed by EIC. 171 Providing and fixing of G.I. chicken mesh of required dimension for the cage at rabbit park etc. as directed by EIC including required 172 Providing and fixing cuboard shutter with two doors formed out of CRCA Sheet , the hinges shall be either plain butt type made from mild steel 1.6 mm thick or double folded type fabricated from mild steel 1.2 mm thick . The number of hinges on each door shall be three 173 Locking mechanism : There shall be suitable locking mechanism not be less than six levers brass lock with duplicate keys of non corrosive material and three way bolting device. 174 FINISH : Almirah should be duly powder coated as per ordered color or as per sample color , All dents , Burns and sharp edges shall be removed from the various components . The components shall be individually pickled , scrubbed and rinsed to remove grease, rust scale or any other foreign element. Immediately after pickling , all the mild steel parts shall be given phosphate treatment. The finish should be smooth and uniform as per direction of EIC 175 Providing and fixing cuboard shutter with two doors formed out of CRCA Sheet , the hinges shall be either plain butt type made from mild steel 1.6 mm thick or double folded type fabricated from mild steel 1.2 mm thick . The number of hinges on each door shall be three 176 DISMANTLING AND DEMOLISHING 177 Demolishing brick work/ cement concrete,rcc manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialat designated spots within township arealead as per direction of Engineer-in-charge. 178 In cement mortar, 179 Dismantling and stacking within at designated spots/place within township area directed by EIC , fencing posts or struts including all earth work and dismantling of concrete etc. 180 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking at designated spots/place within township arealead as per direction of Engineer-in-charge.. 181 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to at designated spots/place within township arealead as per direction of Engineer-in-charge. 182 (III) ELECTRICAL WORKS 183 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 184 16 way, Double door 185 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 186 40 A 187 Providing and fixing of 6 amps. to 32 amps. ratings , DP MCB, “C” curve, 10 KA breaking capacity 188 Providing and fixing of 6 amps. to 32 amps. ratings , SP MCB, “C” curve, 10 KA breaking capacity 189 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. GROUP A 190 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 191 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 192 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 193 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 194 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 195 P/F Exhaust fan 200 mm sweep including making arrangment for fixing in the opening or in the ventilator including louvers/shutters / including making the hole to suit the size of above fan, making good the damage, connection, testing, commissioning etc. as required 196 Supplying and fixing 1X20W tube light with fitting complete. 197 1X10W MIRROR LITE 198 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia upto 300 mm 199 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 200 25 mm 201 32 mm
Contract Date: Jul 31, 2025 Contract Value : 1.63 Crore
Boards / Undertakings / PSU No of Bidders 19
Uttar Pradesh View Result →
35.
Housing Urban and Rular Development #6903513 AOC
Tender For Various Electric Work In Rambagh At Amber Palace, Jaipur. - 1 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 2 25 Sq.mm. 3.5 Core 3 35 Sq.mm. 3.5 Core 4 50 Sq. mm 3.5 Core 5 Providing & Fixing ofAC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 3 pole Power contactorswith following AC 3 Rating 32 Amp. 7 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 8 One day & week reserve (digital type ) 9 Providing & Fixing ofAC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 pole Power contactorswith following AC 1 Rating 10 63 Amp 11 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 12 4 pole MCCB With Thermal Magnetic release 13 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 14 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 15 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 16 Supplyandinstallationofhigh tensile low carbon steel rod molecularly bonded with 99.9 % Copperthickness (250 microns) andconfirming toUL 467, IS/IEC 62561-2of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- 17 (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole 18 (b)filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts 19 © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt 20 (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. 21 (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. 22 (e) Test certificatesfor confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 23 17.2 mm thick and 3 Mtr. Long 24 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25 20mm x 3mm G.I. ( Hot Dipped) Strip 26 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- 27 (a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided 28 (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. 29 [c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra ) 30 (d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. 31 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. 32 (f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra ) 33 (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. 34 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 35 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 36 Electrolytic grade Aluminium bus bar 6010 grade 37 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 38 Three phase Ammeterwith Inbuilt Selector Switch 39 Three phase Voltmeter with Inbuilt Selector Switch
Contract Date: Feb 25, 2025 Contract Value : 5.68 Lakh
Boards / Undertakings / PSU No of Bidders 3
36.
Defence #6886994 AOC
Provision Of Stfe Manufacturing Facility In Drdo Land Near Batl Complex At Thiruvananthapuram; SUBHEAD-I :Dismanteling Works , Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) , Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. , Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 10km initial lead, for all leads including all lifts involved. , Credit for Reinforcement steel obtained form above items , SUBHEAD-II :EARTH WORK & EXCAVATION : , Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. including pumping out water as required or liquid mud, , All kinds of Soils , Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. . including pumping out water as required or liquid mud, , All kinds of Soils , Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. , Supply,Laying, spreading and compacting stone aggregate of specified sizes to Rubble solling specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . , SUBHEAD-III :ANTI TERMITE TREATMENT : , Supplying chemical emulsion in sealed containers including delivery as specified. , Chlorpyriphos/ Lindane emulsifiable concentrate of 20% , Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:With Chlorpyriphos/ Lindane E.C. 15% with 1% concentration. , Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 15% with 1% concentration. , SUBHEAD-IV:PLAIN & REINFORCED CEMENT CONCRETE : , Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : , 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: , 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. , Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. , Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works upto plinth level , All works above plinth level upto floor v level , Concrete of M25 grade with minimum cement content of 330 kg /cum , All works above plinth level upto floor v level , Add/ Deduct for using extra/ less cement in the items of design mix over and above the specified cement content therein. , Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles , Supplying, fabricating and fixing in position reinforcement bars at all levels and positions including the cost of steel, straightening, cutting, bending, binding and placing in position etc., as per drawings and specifications including the cost of binding wire, labour etc., all complete for reinforced concrete. , Thermo-Mechanically Treated bars (Fe 500 Grade or More) at all levels , Centering and shuttering including strutting, propping etc. and removal of form for : , Foundations, footings, bases of columns, etc. for mass concrete , Lintels, beams, plinth beams, girders, bressumers and cantilevers , Columns, Pillars, Piers, Abutments, Posts and Struts , Weather shade, Chajjas, corbels etc., including edges , Suspended floors, roofs, landings, balconies and access platform , Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. , Stairs, (excluding landings) except spiral-staircases , Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). , Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) , Vertical load testing of piles in accordingwith IS 2911(Part IV) including installation of loading plateform and Preparation of pile head or construction of test cap and dismantling of test cap arter test etc., complete as per specification & the direction of Engineer-in-charge Single pile upto 50 tonne safe capacity Routine test , SUBHEAD-V : STONE & BRICK MASONRY : , Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with, Cement mortar 1:6 (1 cement : 6 coarse sand). , Providing and laying autoclaved aerated cement blocks masonry with 150mm/200mm/230/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). , Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. , SUBHEAD-VI :PLASTERING & SURFACE TREATMENT : , Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : , Flush/ Ruled Pointing , 6 mm cement plaster of mix cement mortar 1:3 (1 Cement : 3 fine sand). , 12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand). , 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand). , 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). , Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. , Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. , Providing and fixing 22 gauge chicken mesh wire at the junction of RCC and brick work with overlapping of 100mm on both sides, etc., complete. , White washing with lime to give an even shade: New work (three or more coats) , Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour (Two or more coats on new work) complete, as per manufacturer’s specification. , Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm , Applying priming coat , With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) , With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. , Painting with synthetic enamel paint of approved brand and manufacture to give an even shade, Two or more coats on new work , French spirit polishing : Two or more coats on new works including a coat of wood filler. , SUBHEAD-VII :FLOORING : , Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). , Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. , Making provision for contraction, expansion, construction and longitudinal joints (size 5x20mm) by groove cutting machine. , Providing and filling in position at expansion joints(size 5x20mm) with poly sulphate sealants of approved brand. , Supply and application of SealArm Tape TPE with adhesive ReArm Bond 4031 for 25mm width expansion joint. Work includes Insert backer rod same or higher dia into the joint and Apply of epoxy adhesiveReArm Bond 4031 first on the flanges of the joint followed by laying tape and press it on the adhesive. Again apply second layer of ReArm Bond 4031 on the tape (sandwiching the tape with adhesive both on top and bottom). Work including surface preparation all incl etc, not incl of joint protection works. Supply and apply of polyurethane sealant to expansion joint. work includes Insert backer rod of same or higher dia into the joint and apply polyurethane sealant - SealArm PU. Ensure that depth of sealant filling is atleast 1/2 of the width of joint as minimum criteria. , Providing and placing the 2.0mm thick and 300mm width aluminium plate as a protection for the tape. , Supplying & Fixing in position of pre-moulded, high performance joint filler board of 25mm thickness in expansion joints in Concrete, brick work, block work or isolation joints and should be rot free and with no bitumen content (ShaliTex Expansion Joint Filler Board of M/s Shalimar Tar Products or equivalent) , 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete. , Providing cement skirting in CM (1:3) 18mm thick finished with a floating coat of neat cementetc., complete. , Supplying and applying Epoxy Flooring System as per the following Specification: Surface Preparation:- Providing and cleaning all floor area to make it free from dirt, dust and other contaminants, making grooves etc .as per manufacturers specification. Priming:- FloArm Primer 1260is a two-component solvent free, low viscous epoxy resin primer for both horizontal & vertical applications. It may also be used for producing leveling and scratch coats for surface preparation prior to final flooring. Epoxy Screed- FloArm ESF 2-M consists of graded aggregates bound is a epoxy resin binder. It is supplied as a 3component system, pre-weighed for on-site mixing. When laid it provides a smooth surface. FloArm ESF 2 M is designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm ESF-2 a Heavy duty, trowel applied flowable 2-3 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >20 N/mm² at 7 days. , Epoxy Top Coat- FloArm SL-2 M consists of graded aggregates bound in a pigmented epoxy resin binder. It is supplied as a four component system, pre-weighed for on-site mixing. When laid it provides a smooth, light reflective surface. It is available in a range of standard colours. FloArm SL-2 Mis designed for use in industrial environments where high abrasion and impact loads are likely. It provides a dense, impervious, coloured and chemically resistant floor surface which is hygienic and easy to clean. The designated floor area shall be surfaced FloArm FloArm SL-2 M a Heavy duty, trowel applied flowable 2 mm thick epoxy resin floor topping. The topping shall achieve a compressive strength of >50N/mm² and a flexural strength of >25 N/mm² at 7 days. Make of Epoxy Flooring :- MYK or as Approved by Chief Construction Engineer (R&D)South. , Anti Static Flooring Surface preparation:- Providing and cleaning all floor surface including wall up to required height to make it free from dirt, dust, loose particles, wax, polish, efflorescence, laitance, curing compound and other contaminants by using wire brush, grinding all sharp edges to make it flush with the surface etc and complete as per manufacturers specification. , Priming:- Prepared substrates to be treated with FloArm SL Conductive system should be primed with FloArm Primer EP. FloArm Primer EP should be mixed in the proportions supplied by adding the entire contents of hardener can to the base can. Once mixed the FloArm Primer EP, should be immediately applied in a thin, continuous filmusing stiff brushes or rollers. Over application and puddles should be avoided. Porous floors may require two coats of FloArm Primer EP. FloArm Primer EP should be allowed to become tack free (over night Air dry) prior to application of Copper tape and subsequent FloArm SL Conductive Undercoat. Copper tape Fixing: - Make a suitable pattern to lay the copper strips of Copper band in a 5/5 m grid. , Screed:FloArm Cempo4 is a three part; epoxy modified cementitious, fine textured mortar for self-smoothing floors creeds in thinlayers of 4mm , Applying undercoat: The mixed undercoat shall be applied with a roller or brush on the primer at a material consumption rate of 6m²/kg for FloArm SL Conductive under coat. Care shouldbe taken to avoid over application or puddles. Theundercoat provides a Conductive system passagetoearth so correct application and strict adherence tocoverage rates are critical to the final electrical propertiesof the completed floor. Adequate ventilation and air movement are necessary for complete curing of undercoat. Thorough covering of earthing connections isessential. The Resistivity of the undercoat needs to bemeasured before applying the top coat (after overnight Air Dry). the surface resistance (FloArm SL Conductiveundercoat) should be: approx. 3x103- 9 x103 Ohm , Applying Topcoat: When mixed, FloArm SL Conductive Topcoat should bepoured immediately on to the surface and spread @2mmwith a steel trowel or a float. Immediately after applicationthe surface should be firmly rolled in perpendicular directions with a nylon spiked roller to help release anyentrapped air in the material and help to spread any slight trowel marks. Make of Anti Static Flooring :-MYK or as Approved by Chief Construction Engineer (R&D)South. , Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. , Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. , Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm , Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. , Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. , Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red , SUBHEAD-VIII :STEEL & WOOD WORKS : , Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete , Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc. , Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including MS pressed blet hinges 2.50mm thick with morter guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: , Profile B, fixing with adjustable lugs with split end tail to each jamb , Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: , 35 mm thick , Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. , Providing and fixing to existing door frames, 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. , Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). , Providing and fixing the following hardware fittings of approved make: , 200mm long SS Tower Bolts , SS Aldrop 300mm long , Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. , 125mm long , Providing and fixing aluminium hanging floor door stopper (Single rubber stopper), ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. , Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. , Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. , Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). , Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws.(Glazing, paneling and dash fasteners to be paid for separately) : , For sliding windows & ventilators including the cost in-built roller track, uPVC extruded interlocks, EPDM rubber,wool pile, zinc alloy ( powder coated) touch locks with hook, zinc alloy body with single nylon rollers (required weight bearing capacity ),neoprene gasket, G.I fasteners riquired size for fixing frame to finished wall and necessary stainless steel screws etc all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazingand paneling to be paid for separately, Only weight of aluminium sections to be measured for payment). , Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : , For fixed portion , Powder coated aluminium (minimum thickness of powder coating 50 micron) , For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) , Powder coated aluminium (minimum thickness of powder coating 50 micron) , Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): , With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) , Providing and fixing Motorised Sliding Door of size 6 x 8 mCE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Inbuilt wicket door with, locking arrangement & auto sensor - (w)1000 x (h)2100 mm Enamel Paint including all necessary fittings,hardwares etc complete as directed engineer in charge. , Providing and fixing Motorised Sliding Door CE Certified As Per European Standard BS EN 13241-1:2003+A1:2011 Single Side 0.50 mm thick GI Cladding Sheet Both Side Automation System : Bottom Drive Enamel Paint including all necessary fittings, hardwares etc complete as directed engineer in charge. , D1 ( 3.5 x 2.1) , D2 (2.5 x 2.1) , Providing and fixing Motorised GI Rolling Shutter CE Certified As Per European Standard EN 13241-1:2003+A1:2011 GI Slat Box Type Guide Powder Coated Motorised System : Indirect Drive With Std. Control Push Button - 1 No. Hood Cover - R/Meter including all necessary fittings,hardwares etccomplete as directed engineer in charge. , RS1 (4 x 3) , RS2 (3 x 3) , Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. , 80x1.25 mm M.S. laths with 1.25 mm thick top cover , Providing and fixing ball bearing for rolling shutters , STRUCTURAL STEEL : , Analysis, Design, Engineering, Preparation of Detailed Drawings, MAnufacturing, Fabrication, Supply, Loading,Transporting to SIte, Unloading, Erection of Steel PEB(Pre-Engineered Building)System, Consisting ofMS Platesof 345MPayield strength and Coating Thickness of 275gsm forcolumns, jack trusses, crane beams, Platforms, canopies, lattice girders, rafter , sub rafters ,at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, chann`els, joists, rails, tees, plates, rounds, squares,etc., of various sizes and other structural steel sections conforming to latest IS CODE including straightening, cutting, welding, bending to shape, bolting,and inclusive ofGrit / sand blasting and applying two coats ofSynthetic Enamel paint over one coats of approved Zinc Chromate primer . , The rate to include the cost of all materials, labours, tools, tackles, cranes, devices and plants, bolts, nuts, washers, clamps, welding electrodes and connection required for work, shims and packing pieces, any cutting, fabrication work required on electrically operated machines in the work shop including transportation to site and erection as per specifications and drawing complete. , a) For trusses , Rafters, gable frame ,lattice girders, Jack Beam, Crane beams, Columns.etc at all heights. , Supplying, fabricating, hoisting and erecting in position Purlins , cladding runners, girts of minium 345mpa yeild strength at all elevations, levels and heights including aligning, leveling, providing and fixing bolts, nuts, washers, comprising MS angles, channels, joists, rails, tees, plates, rounds, squares etc.,of various sizesincluding straightening, cutting, welding, bending to shape, bolting,Acid Pickling / GALVANISING of minium 120gsm &inclusive of following finishes. structural Grit blasting and applying two coats ofSynthetic Enamel paint over one coat of Zinc Chromate primerofapproved make and colouras per specifications and drawing complete. , Providing and fixing in position GI High Strength Foundation Bolts of approved make ofwith nuts of various diameters and lengths confirming with IS 4000-1992, Class 8.8 Type I for joining of various Structural components like Column, Rafters, Jack Beams,etc., including work at all levels and locations complete all as shown in the drawing , Roof Sheeting TOP SHEET : Supply of 360-degree FORTISS™ 470 standing seam panels shall be 470mm effective cover width, 73mm rib height, with strengthening rib/ flute in the pan for strength. The end lap shall be seamed with 360 degree seeming using Seamer machine. The sheeting material shall be 0.50 mm Base Metal Thickness (BMT), (0.55mm TCT, 0.58mm TPT). The steel sheet is having high tensile strength G300 (Fy=300Mpa), metallic coated with Zinc-Aluminium alloy (i.e. 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , ROOF INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - Bottom Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Sheeting :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Wall Panelling OUTER SHEET : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Steel should be metallic coated with Zinc-Aluminium alloy (i.e., 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min 150 g/m2 total on both side), pre-painted with NextGen COLORBOND® XRW. The sheet conforms to general requirement of AS/NZS 2728 type 4 / IS 15965 class 3 durability of Tata BlueScope Steel make. The sheet shall be IGBC Green pro, Griha, EPD certified and steel sheet shall have brand marking of coated steel manufacturer (product details, date, mfg. name, etc.) on back side at regular interval confirming genuinity of the material. , Wall INSULATION: Insulation shall be 50mm thick, density 48kg/m3 Rockwool with or without facing as per design requirement complying with IS8183 BS - 3958 Part-5. ASTM C592-80, as approved by engineer in-charge shall be laid uniformed over Purlin. SUB GIRTS: LYSAGHT ZED-plus™ purlins and Girts 1.5mm thick high strength galvanized steel with min 345 MPa yield strength, zinc coating of Z275 (275 g/m2 minimum coating mass) confirms to IS 277 / IS 15961 pre-punched to the required dimensions, suitable for roof and wall cladding support and portal framing up to a certain span. The design of cold formed ZED-plus purlins sections shall be subject to the requirement of IS 801 / AISI 1996, cold formed steel structures code. LINER - INNER Sheet : Pre-painted Zincalume trapezoidal sheets shall be made of 0.45mm BMT (0.50mm TCT, 0.53mm TPT), G550 (min 550 yield strength), 1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg of Lysaght Trimdek. Color : COLORBOND XRW Standard or as Approved by Chief Construction Engineer (R&D)South. Make of Wall Panelling :-Tata Blue Scope or as Approved by Chief Construction Engineer (R&D)South. , Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. , Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. , 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, , shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : , 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) , Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). , SUBHEAD- IX : MISCELLANEOUS: , Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: , a) Applying a slurry coat of neat cement using 2.75 kg/Sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. , b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. , c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ Sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. , d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3 mm deep. , e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge, with average thickness of 120 mm and minimum thickness at khurra as 65 mm. , Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , Single socketed pipes of 110mm diameter , Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. , 110mm Bend 87.5° , 110mm Shoe (Plain) , Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. , 110mm , Providing and fixing Duraborad HD100(Formely Known as Capcell HD100/Silflex) The most Compressible Filler boad for expansion joint with Density of 100kg/cum.in 100mm Thickness , SUBHEAD-X : SANITARY SERVICES: , Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. , Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : , W.C. pan with ISI marked white solid plastic seat and lid. , Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc., including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. , Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. , Providing and fixing white vitreous china flat back urinal basin of 430x260x350 mm size. , Providing and fixing C.P 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. , Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : , White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. , Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. , Providing and fixing toilet paper holder, C.P. Brass. , Supply and fixing of 15 mm CP Health faucet Cum bib tap with 1.25 mts long tube with end nuts and hook and 1 no 15 mm CP brass angular stop cock with wall flange, Hook to be fixed with CP brass with suitable counter sunk screws, all of approved make etc., complete. , Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. , Granite of any colour and shade. , Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc., complete as per design approved by Engineer-in-Charge. , Granite Work , Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc., including moulding, rubbing and polishing of cut edges etc. complete. , Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. , Granite Stone of approved shade , Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. , 32mmdia Flexible pipe , Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. , Providing and fixing CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , Providing, fixing, testing and commissioning of 75 mm pipe diameter uPVC SWR Type B pipe comforming to IS : 13592, including jointing with seal ring conforming to IS : 5382 for vertical pipe & Selfit uPVC Adhesive solvent joint inside in the toilet, including all fittings such as bends, junctions, inspection doors, offests, cowl, clean out, access pieces/plugs etc. complete the job. The rate shall be including all the engineered support at every one Meter (support, hanger, nuts/ bolts, anchor fasteners, fixing clamp/channels with U-bolts, etc) as per detail technical specification etc. complete the job. , 100mm dia upvc/ SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete for UPVC SWG Pipes conform to is 13592-1992. , 100mm dia UPVC/SWR Single socket , 75mm dia UPVC/SWR Single socket , Providing and fixing PVC door bends as per IS - 13592-1992 single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. , 100x100x100 mm , 75x75x75 mm , Providing and fixing terminal guard, Sand cast iron S&S as per IS - 3989. , 100mm dia. , 75mm dia. , Providing and fixing M.S. stays and clamps for pvc pipes of diameter. , 100mm , 75mm , Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, Sand cast iron S&S as per IS: 3989. , 100 mm inlet and 100 mm outlet , Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : , 100mm dia. , 75 mm dia , Supply and fixing in position best quality and approved make CP brass coat hooks with flanges fixed to wall/door shutters with necessary screws washers etc., complete. , SUBHEAD-XI :WATER SUPPLY SERVICES: , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. - External Work. , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc., , 15 mm dia nominal bore , 20 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 25 mm dia nominal bore , 32 mm dia nominal bore , 40 mm dia nominal bore , Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. , Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : , 25 mm nominal bore , Providing and fixing CP brass bib cock of approved quality : , 15 mm nominal bore , Providing and fixing CP brass stop cock of approved quality : , 15 mm nominal bore , Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. , 15 mm nominal bore , Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. , SUBHEAD-XII : INTERNAL ELECTRIFICATION : , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia heavy gauge PVC conduits concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Ceiling fan point controlled by one 6 A switchand electronic fan regulatorof 100 W step typewith concealed MS fan hook box. , Exhaust fanpoint controlled by one 6 A switch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia, 14SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbowsand anodised GI Switch box with modular switch and the box coveredwith stainless steel front plate including connections to Earth terminal. , One Light point controlled by one 6 Aswitch. , Two Light point controlled by one 6 Aswitch. , Three Light point controlled by one 6 Aswitch. , Four Light point controlled by one 6 Aswitch. , Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 2.5 Sq.mm & 1 run of2.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductorwires , run in and including 25mm dia , 14 SWG black enameledMS conduits surface / concealed in wall / ceiling conforming to IS732 including all accessories such as junction boxes, conduit bends elbows etc including connections to Earth terminal. , One Light point controlled by one 6A SP MCB , Two Light point controlled by one 6A SP MCB , Three Light point controlled by one 6 ASP MCB . , Four Light point controlled by one 6 ASP MCB , Point Wiring for Light/ Fan/ exhaust fan with2runs of 1100V grade 1.5 Sq.mm & 1 run of1.5 Sq.mm FRLS insulated multistranded Copper wires, run in & including 25mm dia, 14 SWGMS conduitssurface / concealed in Slab/ wall after necessary chase cutting with finishing/surface in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI Switch box withmodular switch and the box coveredwith front plate and alsoincluding connections to Earth terminal. , One Light point controlled by one 6A Switch , Two Lights point controlled by one 6A switch. , Three Lights point controlled by one 6A switch. , Four Lights point controlled by one 6A switch. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 32mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and fixing of 6A, 3Pin Socket outlet with 6Aswitch in Lighting switch boards. (Dependant). , Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A ratingwith wiring of 2 Runs of 2.5 Sqmm and1 Run of 2.5 Sqmm FRLS, PVC insulatedmultistranded Copper conductorwires run inand including 25 mm Dia, 2 mm thick PVC conduit. (Independant). , Supplying and fixing suitable size GI box with modular Stainless Steelplate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in Clean Room). , Supply and Wiring with the following size 1100V grade PVC insulated multistrandFRLSCopper conductor wires inand including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories suchas junction boxes, bends, elbows including end terminated with suitable lugs. , 2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including25 mm Dia PVC Conduit (For Lighting Circuit) , 4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wiresin and including32 mm Dia PVC Conduit (For Lighting Sub Mains) , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 36 W Surface mounted LED 4 Feet LengthLuminaire , (Philips : BN308C LED40S-6500 L120 PSU WH/or Equivalent as per approved makes) , 1 x12 WSurface MountedLED Luminaire , (PhilipsCat No : SM250C LED 12S-6500PSU WH or Equivalent as per approved makes) , 40 WRecessMountedLEDLight Fixture , (PhilipsCat No :RC 380 B LED 40S-6500 G4L60W60 PSU OD/Equivalent as per approved makes) , 20W Recess mounted DownLight Fixture , (PhilipsCat No DN296B LED20S-6500 PSU WH S2/Equivalent as per approved makes) , 36W Surfacemounted SquareLight Fixture , (PhilipsCat No SM36S -6500 G6L54W54PSU OD/Equivalent as per approved makes) , 40 W Bulk Head Light Fixture Indoor , (PhilipsCat No WT 202W LED 10S CW PSU S3 PC/Equivalent as per approved makes) , 210WLED High Bay Light Fixture , (PhilipsCat No BY616P LED200S 5700 WB PSU GR/Equivalent as per approved makes) , 104WLED High Bay Light Fixture , (PhilipsCat No BY225P LED104S CW SYWB PSU FG GR V2/Equivalent as per approved makes) , 36WLED2 X 2 Top openable cleanroom Light Fixtures , (PhilipsCat No CR652B LED36S-6500 PSU CA BO W30L120 WH /Equivalent as per approved makes) , Supply and Installation Testing and Commisioning of 1200 mmsweep single phase Ceilingfan including fixing accessories etc., complete.( BEE 5 star rated ceiling fan ) , Supply and Installation Testing and Commisioning of 600 mm dia sweep single phase wall mounted fan including fixing accessories etc., complete. , Supply and Installation Testing and Commisioning of 600 mm dia Air circulator single phase wall mounted with metal blades including fixing accessories etc., complete. , Supply and commissioningof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials required. , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , Installation of 1200 mm sweepwhite colour Ceiling fan with standard down rod(600mm length down rod in false ceiling areas) andall accessoriesas required etc complete. , Installationof305 mm sweep Exhaust fans with Metallic blades and MS gravity louversincluding all accessories / Installation materials as required. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (8 + 24), Double door , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 160A 4P MCCB, 25 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 40A Three Pole MCB 10 kA , SUBHEAD-XIII : AIR CONDITION: , HVAC SYSTEM , All works should include Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over , All the equipments shall be five star rated only , All Techincal data sheet & drawing shall be submitted and get approved by department before supply , All equipment factory inspection shall be carried out by department , First prefers as per BOQ followed by Techincal specification , VARIABLE REFRIGERANT FLOW (VRF) / VARIABLE REFRIGERANT VOLUME (VRV) , Supply, Installation, Testing & Commissioning & Handing over of the following: , HIGH SIDE VRF/VRV EQUIPMENT , VRF/VRV HI BRID AIR-CONDITIONING EQUIPMENTS: (100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of VRV/VRF air conditioning systemunit suitable for cooling and heatingmode having all hermetically sealed inverted type screw compressor with 5 Star and above Rating as per OEM comprising of Modular type high efficiency Twin Rotary MultipleCompressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below: , The unit mounted starter panel shall be complete with IP-65 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. , All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. , Modular type outdoor units equipped with highly efficient scroll compressors, withinvertertype compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below). Shifting of Out door units from GF to repective location is part of VRF vendor scope . ODUs shall have service valve station for easy operations and monitoring of system , All VRV units should be compatible for third party BMS integration .necessary integrator should be consider in part HVAC VRF/VRV vendor scope (Bacnet over MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF/VRV indoor and outdoor units and same to be located in a specific location as per client requirement. , Supply & providing of MS stand for VRF/VRV ODU along with proper supports-suitable for above configuration , Installation and pressure testing with nitrogen Gas, Vaccumising including all consumables for all system shall be part of scope of supply (Pre commissioning ) , First Filling, testing, commissioningincluding topping up of R410 A Refrigerant Gas. , Factory acceptance test to be conducted for all the units and cost of the same to be included , Testing tools and instruments of approved make and required quantity tobe maintained by Contractor , Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations , Central remote controller should be considered and provided along with VRF/VRV units , With all necessary accessories including vibration insolation i.e fixing etc complete. , Lifting, shifting and positioning of VRF/VRV System as per design location , Outdoor unit suibtable for both cooling & heatingmode having all hermetically sealed inverted typescroll compressor, minimum two compressors for above 14hP Modules, microprocessor based controller. , The unit shall be delived the rate capacity at AHRI conditions and work even at 50c ambient temperature with out tripping , The COP at AHRI conditions shall not be less than3.1 and IEER not less than 6.5.The motor shall be by IEE3 Rated , (*Note:The cost includes themaintenancegranttee includes 24months from the date ofCommissioning without any additional cost) MAKE: Daikin, Blue star, Voltas, Carrier, Trane. , Outdoor Unit (ODU) : Cooling Capacity : 218HP (OFFICE, LAB & QC LAB) , Outdoor Unit (ODU) : Cooling Capacity : 65HP (CLEAN ROOM) , Outdoor Unit (ODU) : Cooling Capacity : 220HP (WORK SHOP) , INDOOR UNITS , Indoor Unit (IDU):Coolingtype All the units should be supplied with thermostat control. The following Indoor unit capacities are required for each type of Room including heating & cooling mode. considered for Auto change over,failure status,overload sequencing etc. Along with proper supports-suitable for above configuration With all necessary accessories i.e fixing etc complete. , It should be suitable for BMS connectivity with necessary accessories. , 4-WAY CASSETTE UNIT , Four way Cassette 1.6TR , Four way Cassette 2.0TR , Four way Cassette 2.6TR , Four way Cassette 3.2TR , HI-WALL SPLIT UNIT , Hi-wall Unit 1.0TR , Hi-wall Unit 2.0TR , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the following Inverter model with5 star capable Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat, cool, dehumidifying, air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation and with copper condenser only. , Hi-wall Unit 1.6TR5 star capable ofdelivering 19200 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , Hi-wall Unit 2.0TR5 star capable ofdelivering 24000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5 , AIR HANDLING UNITS , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of following capacity floor mounted Thermal Break Double skin construction with internal and external sheets of 1.0 mm thickness with galavanizing of 120 gm/m2 ,Air handling unit made out of extruded aluminium structural frame work. Panels shall be made of 50 mm PUF injected panels having density 43 Kg/m3 in galvanised sheet casings having scratch free preplasticised coating on galvanised sheet on external side and plain GI inner sheet. The whole unit shall be mounted on spring isolators , i) The Air handling unit shallcomprise of fan section with Plug Fan/ Backward curvedfanwith limit load characteristics , spark proof fan. fan mounted on the scroll and not on the casing, coil section comprising of vrv/vrf water coil,stainless steel drain pan under coil section, Filter section comprising of prefilter 10 micron and 3 micron fine filters,mixing box along with RA and FAdampers etc. complete in all respect whether specifically speltor not but required to complete the system works. , The entireunitcasing shall be weather proof , made out of50 mm thk.43 Kg/ cum densitydouble skin PUF panels. The entire assembly of the unitshall be mounted on a rigid GSS base frame. Inner skinof the panel shall be 1 mm thickGSS plain and the outer skin shall be with 1 mm thk. Pre plasticized powder coated. The total unit along with VRV/VRF coils and hot water coil shall be AHRI certified. The face velocity of the coils shall not exceed 500 FPM . Theface velocity across the filters shall not exceed 500 FPM. , The coils and filters shall be full face of the unit. The fan and motor shall be mounted on a common base frame with cushy foots / spring isolator to avoid vibration transmission to the base of the unit. The motor shall be effiency 1 and with VFD compatable. , The fan shall be AMCA certified and motor shall be energy efficientEFF1. The fan out let velocity shall limit to 12 m/ sec. The fan access door shall have safetydoor interlock arrangement with motor. The unit shall be supplied withfire retardantdouble canvass connectionbetween the fan out let and supply air flange. , Variable frequency drives including harmonic filters and surge suppresors to be installed in independently with bypass starter panel and also differential pressure sensorwith cabling from the sensor located on the duct to the VFD for Air handling units of following capacity Motors including necessary fittings and fixing accessories etc., complete , The unit shall be supplied with an outletflange at the the supply air side along with opposed blade volume control damper. The damper casing and blades shall be made out of 16 G Aluminum. , The scope includes one set of commissioning filters along with the VFD & Starter panel with Bypass and control panels with MCB,MCCB. , The AHU unit shall outdoor type with all season weather proof protection , The noise level at all-round the unit shall limit to 60 dBA from 1 m distance to the unit. , The fan curves, coil selectionandtechnical data sheet shall be submittedby vendor for scrutiny. , The unit shall be included withAHU & VFD DRIVE STATER & CONTROL PANEL , The unit shall be included withAHU CONTROLL KITS WITH CORDED REMOTES , Unit shall be ultra violet lamp to kill germs/fungus , AHU1 - 30TR capacity , total air qty 12000 cfm, 65mm Static pressure with suitable High efficency motor, 24sqftarea of6 rowcoil(QC LAB). , Heater section should be with 8kW electric strip heater in 2 banks (QC LAB). , AHU2 - 52TR capacity , total air qty50000 cfm, 150mm Static pressure with suitable High efficency motor, 100sqftarea of6 rowcoil (ASSEMBLY HANGER). , Heater section should be with 12kW electric strip heater in 2 banks (ASSEMBLY HANGER). , AHU3 - 44TR capacity, total air qty 17600 cfm, 125mm Static pressure with suitable High efficency motor, 35.2sqftarea of6 row coil (WORKSHOP). , Supply and fixing of thyristor control Duct Heater Bank for humidity control 14kw capacity & necessary accessories to maintain RH (WORKSHOP). , Imported fittings like Y-Joints and headers etc as per the layout (additional supports should consider for both ends of the Y joint) With all necessary accessories i.e fixing etc complete. , CENTRAL CONTROLLER & REMOTE SYSTEM (FOR VRF UNITS) , Centarl controller integrating advanced I Touch screen display Controller type (System controller) for floor Indoor units with necessary software & spare parts. It shall be BMS compatible with BACNet over MSTP output to connect to the main IBMS system and showes real time data for both temperature Limitation and RH% in screen display. This Controllershall be stand-alone controller with features like visual navigation, graphical report, Multi-PC accessand have the capability to program for sequential operation of indoor units etc.,complete. , LOW SIDE VRV/VRF EQUIPMENT , REFRIGERANT PIPING , Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber typetubular insulation betweenindoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all piping should be run in perforated cably tray.Cable tray qty specified seperately.. MS supports for refrigerant piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. Class O insulation to be considered for the piping insulation. Cu.pipes shall be supported with PVC sleeves with clamps around and all wall/partition crossings shall have PVC sleeves , 41.3mm OD (insulation =19 mm thick) , 38.1mm OD (insulation =19 mm thick) , 34.9mm OD (insulation =19 mm thick) , 31.8mm OD (insulation =19 mm thick) , 28.6mm OD (insulation =19 mm thick) , 25.4mm OD (insulation =13 mm thick) , 22.2mm OD (insulation =13 mm thick) , 19.1mm OD (insulation =13 mm thick) , 15.9mm OD (insulation =13 mm thick) , 12.7mm OD (insulation =13 mm thick) , 9.5mm OD (insulation =13 mm thick) , 6.4mm OD (insulation=13mm thick) , DRAIN PIPE , Supply & Installation ofCPVC drain pipe insulated with 6 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided. , 32 mm dia , 25 mm dia , Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unitthrough PVC Conduit. , Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration also including coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. , Supply and installing following size of perforated Hot Dipped Galvanised iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections,joined with connectors,suspended from the ceiling with G.I. suspenders including including Cover on above tray, G.I. bolts & nuts, etc. as as required and also inculding 14 SWG GI cover sheet with 40x5mm GI strip on both sides. , 150mm wide x 75mmHeight, 1.6mm thick , 300mm wide x 75mmHeight, 1.6mm thick , 450mm wide x 75mmHeight, 1.6mm thick , MECHANICAL VENTILATION SYSTEM , Supply, Installation, Testing & Commissioning & Handing over of the following: , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the Circular Inline fan Supplying, installing, testing and commissioning of low noise silent type Inline fan with @15mm WC static pressure. The motor shall be suitable for 220 volt single phase 50 cycles AC supply, 6/15 Ampplug and wiring between the fan and the socket andlow sound level exceeding not more than 50dBA. Fan shouldbe complete with all accessories, gravity louver/ shutter as required etc., as per manufacturer specification including transportation to site, all mounting arrangements like brackets etc.,as per specification including transportation to site, all mounting arrangements like brackets etc. It should be suitable for BMS connectivity with necessary accessories and cost of all accessories and all labour charges complete. , Circular Inline fan 100CFM/15mm WC static pressure , Circular Inline fan 200CFM/15mm WC static pressure , Circular Inline fan 400CFM/15mm WC static pressure , Circular Inline fan 500CFM/15mm WC static pressure , Circular Inline fan 600CFM/15mm WC static pressure , Circular Inline fan700CFM/15mm WC static pressure , Circular Inline fan 800CFM/15mm WC static pressure , CLEAN ROOM , CLEAN ROOM FALSE CEILING , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of the False ceiling panels are designed to fit within each other and suspended by threaded tension bars to the overhead support at fixed intervals , Standard Ceiling Panels have a composite construction of two skins of powder coated GI over an GI frame work with a sealed and insulated interior. 150-200 Kg per sq. mtr load bearing & factory manufacture only to be supply. , 50mmdouble Skin Walkable False Ceiling made of 0.45 mm both Top & Bottom with pre coated GI Sheetswith mounting accessories PUF as in fill (40 +/-2 kg./m3).False ceiling support rods lengthsuit to site condition. Note: 1.All ceiling joints and gaps between panel to panel, ceiling elements (such as HEPA module, diffusers, pipe & electrical drops etc.) etc. to be sealed usingApprovedfood grade silicon sealant of same or nearest colour as panel. The gap above panel to civil wall shall be properly closed with aluminium L - angle secured properly between civil wall and panels. All the gaps between panel to panel shall be closed with GI pre coated External Flashing . All the gaps between ceiling elements and ceiling panel shall be sealed using food grade silicon sealant of the same colour as the panel. , CLEAN ROOM PANELS , Standard wall partitions are a composite construction of two skins over an GI frame work with a sealed and insulated interior. Standard panel dimensions are 1200 mm. Standard panels have an overall thickness of 80 mm.Including Silicon Sealant. The self supporting internal walls are constructed with an interior floor Flashing to suit panel thickness.The Partition seams are sealed by silicone(Food grade) with a perfectly flush finishing. The panels should be factory manufacture. , CLEAN ROOM COVINGS , Extruded Aluminum Powder Coated /Anodized clip on type covings of 60mm radius for Panel to Panel and Panel to Ceiling. , Horizontal & Vertical Coving , 3DCorner Powder Coated , 2D Corner Powder Coated , AL powder Coated TEE Support for Ceiling Panels with threaded Rods and clamps , CLEAN ROOM DOORS , Doors are designed to fit flush into the wall panel / civil walls system on both sides and are supplied in different dimensions. Doors are fabricated from Pre Coated GI sheets & Pufas infill(48 +/-2 kg./m3). Shutter has sheet thickness of 1mm and the frame of 1.2mm. jam depth of door shutter inline with adjacent panel thicknessand shutter width of 40mm. Doors are available in various sizes as per the requirement. The following accessories are a part of the door: Note: 1.All joints between view panel and door panel to be sealed usingapproved food grade silicon sealantof the same or nearest colour as the panel. 2.Colour of the door panel:Same as Panel Colour or Blue 3.Double face VHB tapes of required thickness or silicon sealant to be provided on the periphery of the view panel frame to avoid any play between view panel frame and the slot in the door leaf. , Shutter Thickness: 40 mm thick , Stainless steel hinges (Any reputed Make) , Stainless Steel D type of handles on pull side , Stainless steel push plates on push side. , Heavy duty Concealed door closure , concealeddouble glazed Vaccumized View panel along with self adhesive tape and silicon sealant (500mmWx750mmH) with toughened glass with 6mm thick and black border , Mortice dead lock (ML100D) with both Side Key Operation Cylinder-Dorset , Concealed Flush Bolt Body with rod , Gasket at bottom for Double Door , Stainless Steel kick plates on both sides of 1.2mm thick with 300mm height for material transfer doors for Double Door. , DOUBLE DOOR SIZE , 3500mm Width X 2500mm Height Door (width of each door 1800mm) , VIEW PANELS ON MODULAR PARTITION , SINGLE GLAZED , All Viewpanel units are Double glazed and round profiled Epoxy based powder coated GI wall panel system. Thickness of 6/8 mm Tougened glass. The window system is completelyof food grade Silicone sealed. All veiw panels to have black border. Approx Size of view panels will be 800 x 1000mm , View Panel on 80mm wall panel , FALSE CEILING CUTOUTS FOR ELECTRICAL & HVAC GRILSS,LIGHT FIXTURES ETC. , Frame Work for Wall Panel Cutouts , Back Boxes for Electrical Sockets includes 3M, 2M, 6M, 8M, Single Phase, Three Phase industrials sockets respectively of apprvoed makes like Anchor, MK, North West & Legrand. , Frame work for False Ceiling Cutouts for Electrical & HVAC , PVC Conduit for Electrical Cables / Data Cables 24mm dia / 40 mm dia respectively , INBUILT RETURN RAISER , Supply and Installation of wall panel inbuiltReturn Air Risers of0.8 mm thick GI sheet & G4 Filter in aluminium frame work with proper fixing arrangement & fastening using SS 304 Dome nuts. to be provided up to the top of the false ceiling for HVAC duct connection. along with Butter fly Dmpers on the Top side. , Inbuilt raiser 600 x 600 , GI RETURN AIR FILTER WITH SS PERFORATED SHEET MODULE , Supply & installation of Return Air Raisers SS PERFORATED SHEET MODULE WITH 20 MICRON FILTER ASSEMBLY TO FLUS FIT THE RETURN AIR RISER PANEL. The RA raiser shall be adequately supported to ensure the rigidity. , 450 mm x 450 mm x 450 mm , Supply and Laying ofSelf levelling Expoxy flooring with Floor Preparation work and application ofone coat primer, screed and finishing with Self levelling Epoxy up to a max of 2mm of approved Colour , INSULATED FLEXIBLE DUCT WITH NECESSARY FIXING CLAMPS ON BOTH SIDE FOR TERMINAL HEPA MODULE , Supply, Installation, Testing and Commissioning of The insulated flexible duct of class 1 air duct, light weight, strong, fully flexible & made of double lamination of films permanently bonded to a coated spring tough steel wire helix. The thermal efficiency is ensured with a blanket of fiberglass wool insulation in between. Necessary Fixing Clamp on both side shall be considered. (With Spigot Connection & Rigid GI Round Duct). Note: Rigid GI Round Duct area shall be part of GI Ducting. Each Flexible connection shall not be more than 1 Mtr. , 200 mm Dia , TERMINAL HEPA FILTER WITH MODULES , Supply, Installation, Testing and Commissioning of H14 HEPA Filterwith Housing & Damper (Bottom Discharge Module Type with SS304 perforated grille of 16 SWG sheet along with SS chain link). Complete Housing (Sides + Top) made of extruded aluminium anodized material and low leakage aluminum collar damper with operating bevel gear arrangement, Diffuser Plate,Housing shall be suitable for fixing the Gel Sealtype (Polyurethane gel) terminal HEPA filter (H-13) with Protective Expanded Metal Screen. The Filter Housing shall have provision for smoke aerosol test point and differential pressure measuring point. The filter mounting box shall have a provision to replace filter & control the airflow from inside conditioned space. The HEPA filter modules are of the following sizes: , Plenum box size of 485x485x220H (530X530mm Flange to Flange) inlet collar with Diffuser plate & TOP entry 305 Sq / dia Collar with necessary clamps completewith gel seal filter minipleat H-13 of Size: 450X450X70mmwith DOP port and bevel gear arrangement room side operation damper. , PRESSURE MONITORING SYSTEM , Supply, Installation, Testing and Commissioning of Compound Magnahelic gauges housed in a SS304 front cover (50-0-50 Pa) complete with PVC tubing and SS perforated nozzle (For Installation in Clean Room Panel for Classified Areas) , MISCELLANEOUS , Commissioning of Classified Areas with Validation reports comprising of: , AHU & Duct leakage testing with pressurization (As per SMACNA air duct leakage standards). This process to be documented. , HVAC testing adjusting and balancing as per ASHRAE standard. , Air balancing with flow hood meter , Room Temperature & Humidity mapping for 24 hours and monitoring for 3 days. , Room pressure balancing with monitoring for 3 days. , HEPA Filter Integrity Test. , Particle count test , Providing all documentation of DQ, IQ, OQ & PQ in approved formats. , The Validation has to be carried out for minimum 3 working days continuously for Air flow, Temperature and Humidity. For Room Pressure Differential continuously for 3 working days. In case of any non compliance the system has to be set right and the Validation has to be carried out once again as per the above schedule. Validation has to be carried out by valued Certification ISO 14644-1 is a widely recognized certification .Its shouldissued by the International Organization for Standardization (ISO) or The FDA, Health Canada, and the EU recognize this certification. , Clean Air Devices Equipments , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of personal Air shower , single entry and single exit,high velocity, low pressure system SS304 nozzles,pre and HEPA fillers, completely self contained unit, utilizing low wall return (floor grill type not accepted) , The Unit shall be consisting of ISO class 8 clean room compatible pre-fabricated units built up, in place having fluorescent lamp with acrylic cover, electronic ballast , both side red and green indicators, elector-magnetic latches on both sides of Dorma make to ensure both doors do not open simultaneously, 5.0 mm thick viewing glass,SS304 finish handles of Dorma make, door closer with hold open arm of Dorma make, blower, control wiring, emergency stop switch etc. , For 3 persons entry , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 3 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 6000X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , Supply, Lifting, Shifting, Positioning, Installation, Testing, commissioning & handing over of stainless steel centrifugal air curtain having following specification.The product should be made up stainless steel 304Grade having 2 Blowers(in M.Steel), 2 Motors operating on three phase , Power =1650 Watt having RPM (Max/Min = 2700) and CFM. Overall Dimension of 3500X230X212(mm) with Noise level < 66 db. Air Curtain should be provided with velocity control switch and a Door sensor. The product should carry manufacturers warranty of one year from the Date of Supply. Along with Fabrication work of providing 2/1 MS Pipe , Tin Sheet as cover, Bracked and screws*Variations acceptable in parameters above - 5-10% The Product should be Supplied along with PVC curtains & SS Bracket for PVC Support. Supply, installation, testing and commissioninging of transparent blue PVC Strip curtain,these medium weight strip will help with temperature control or dust exclusion without impeding access, It is suitable for the door is the main entry gate of the premises, means exposed to air.The Product should be complete in all aspect as per Engineer incharge instructions , SS/PP Furniture , Design, engineering, fabrication, supply, erection and testing of Cross over bench made up of 10 mm thick PP sheets of size which has to fully fixed in the designated placein the changeroom, with heat welding .Bottom of bench will have pegion holes for keeping dayshoes/CR sleepers of equal size 250 mm X182 mm in two rows. , Design, engineering, fabrication, supply, erection,testing and commissioning ofgarment cubicle compatible for ISO class 8 cleanroom either SS304 sheet material for keeping maximum 15 cleanroom garments including 15 sets of garments, sliding doors, glazing, UV light, Pre filter, HEPA filter and blower for recirculation of air, complete ready to use. , ELECTRICL LIGHTS AND ACCESSORIES , LIGHT FIXTURES , Supply,Installation, Testing & commissioning of following LED light fittings for lighting fixture with accessories and LED chip. The Luminaire shall be with CRCA housing and Luminaire and an operating Voltage Range of 120 - 277V, Internal Surge Protection 2.5KV. , 40W 2x2 (600mmx600mm) LED Screw less Clean room recess mounted bottom opening luminaires with toughed glass with diffused acrylic cover, construction of the housing with engineering push back mounting arrangement system of Approved make. System output 4000 lumens to be considered.(Philips or equivenlant) , Electrical Cabling with PVC Conduiting for the Lights 3 Core1.5 Sqmm , POWER SOCKETS , Supply, Installation, Testing & Commisioning of following Plug sockets & Push buttons. The assembly shall be housed in metal box / on partition / on wall concealed type. Rate shall include the internal wiring, terminations, GI back box and front face plate, enclouser with fixing accessary like lugs, screws, blot nuts, ferruls etc. as per tender technical specifications.Necessary wall chipping, drilling & fixing of back box in concelead type. Rate shall be included backbox fixing concelead on the walland chipping along the wall fixing chicken mesh and making good surface of wall as required at site. Note : Modular sockets Back box should be considered 45mm depth only. , Emergencystop push button station with enclosure fixed on wall or on required MS angle support with all its accessories of approved make. , EARTHING , GI Plate Earthing , Supply and Laying of following earthing strips / earth wire of the following sizes with required accessories like clamps,bolts & nuts, painting. Two numbers of earth strips should run along with cable tray/civil wall with proper using bolt and nuts for strips connectivity and two earth points shall be end terminated for all equipments, motors, all Electrical and ELV panels, DB etc., refer the earthing schematic for considering the earth strips. , 50mmx6mm GI Strip , DRAIN PIPE , Supply & Installation ofPVC drain pipe insulated with 9 mm thick closed cell FM approved class O nitriler rubber insulation. Necessary U trap for units with clean out plugs to be provided , 40mm dia , Sheet Metal Work usingFactor Fabricated Duct with Ductmate (TDF) Flanges for all sizes of the duct. Fabrication as per SMACNA Standards , Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates.In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approvaland tested for thickness and zinc coating at contractor’s expense. , All duct construction and installation shall be in accordance with SMACNA standards.In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. , All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. , To ensure the air tightness, all ducts shall be checked with Duct pressure Test after completion of duct installation but before applying insulation , Guide vanes to be installed in elblow, reducers and other accessories , Stiffernner to be considered for ducts with more than 1200mm wide ducts , Duct joining shall completed with adhesive type gasket and sealant , All ducts needs to properly supported with suitablewire supports as per makes given in make list. The cost shall be inclusive of anchor fastners/wedge supports suiting to steel structure. , With all necessary accessories i.e fixing etc complete. , Rectangular Ducting , Sheet Metal Ducting As per Specification. Pressure 500 Pa , 24 G Ducting with Factor Fabricated Duct/ TDF flanges , 22 G Ducting with Factor Fabricated Duct/ TDF flanges , 20 G Ducting with Factor Fabricated Duct/ TDF flanges , Thermal & Acoustic insulation , Thermal Insulation for ducts , Supply, installation and testing of Class- O, 25 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air ducts with density not less than 50 kg / cum. Microban antimicrobial protection insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 19 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. , Supply, installation and testing of Class- O, 13 mm thick Closed cell elastomeric insulation for thermal insulation for indoor supply air / return air ducts with density not less than 50 kg / cum. Insulation material to be fire retardant. Joining tapes & low VOC adhesive to be supplied with the insulation material by the insulation material manufacturer. Refer method statement in technical specification for insulation works. , Acoustic Insulation for ducts , Supply, transportation , Lifting , Shifting ,installation ,testing and commissioning of Acoustic insulation for ducting with 50mm TF quality thermocole, density 18kg/cum, chicken wire mesh and 2 coats of 12mm thick sandcement plastering for exposed ducting. , Air Terminal Devices , Supply, installation, testing and balancing Powder Coated extruded aluminium grilles with collar damper for supply and return distribution(colour for the grill to be confirmed by department before placing theorder) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later. Single / 2 way / 4 way deflection shall be confirmed later. , Supply, Fixing, Testing and commissioning of Aluminium powder coated4-Way Diffusers with Anti smudge ring and all fixing accesseroies as per standard specifications and practice. , Supply, installation and testing ofJet diffuserwith fire resistance flexible double canvas Connection for supply distribution(colour for the Jet to be confirmed by consultant/ PMC team before placing theorder) , Ø 315 , Supply and fixing of 18G circular butterfly damper with provision to fix to the rectangular duct with GI circular flanges. , Supply and fixing of Insulated Aluminum flexible duct with 25mm thick glass wool insulation covered with aluminum foil suitable to connect the ducting including necessary clamps at both ends of size , Acoustic Insulation for AHU rooms , Supply, installation and testing of acoustic insulation on walls & ceilings for the AHU Rooms with 50mm thk. 24 kg/ cum density Resin bonded fiber glass covered with 24 G GI perforated sheet as per specification. The FG slabs shall be placed in the grid of 600mmx600mm centers formed out of GI channels. , Supply and Fixing of Fresh Air / Exhaust air Louvers with brass wire mesh backing with Pre filter along with Dampers for all AHU room fresh air wall openings. , Supply, installation and testing of Factory fabricated Rectangular shape - GI Volume control dampers, 1.6-mm GI Steel Frame, 1.6-mm GI blades, 150-mm width, with required hardware and accessories. Stiffen damper blades for stability. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper. , Supply, installation and testing of Aluminium powder coated fresh air intake / exhaust air louvers backing with pre filters complete with HDPE insect mesh with cowl mounting frame and 45 deg angle suitable for protection against splashing rain water fixed in a powder coated Aluminium angle mount frames as required for all AHU ROOM fresh air wall openings. , Supply, installation and testing of Motorized Fire dampers (MSFD) with ON/OFF type actuator. The dampers to be fire rated for 120 minutes at 250Deg C. Fire damper to be provided with matching flanges on both sides. Fire dampers should be supplied with extended fire rated sleeves. Actuators shall be for spring return type & shall be fire rated for 120 minutes @ 120Deg C. Actuators to be internally mounted. Actuators should be suitable for BMS connectivity with necessary accessories. , Note:Duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper. , Fire damper , Actuator,Sensor,Control panel and relay/communication module, interlinking cabling , Supply, installation and testing ofGI Non ReturnDampersat suction & discharge side, suitable for duct mounted including mating galvanized angular iron flanges. , Supply, Installation, Testing and Commissioning of Fire Retardant Canvass Connections with MS Eoxy painted / Al powdercoated finish angle flanges on both sides as per the specifications and approved drawings. , Supply, installation, testing and commissioning of FM approved 32mm thickness of closed cell nitrile rubber without aluminium foil temperature range from -10ºC to +60ºC, Class O fire category and as per specification.for Underdeck insulation, as per technical specifications and as shown in approved drawings. Adhesive shall be used as recommended by insulation manufacturer for applying over concrete structures and it shall be green building complaint. Makes: Galaxy, sheth insulation, ALP Aeroflex,neothermalinsulation. , MS structural Steel for supports ofUnit, Piping, Control cabling supports including fabrication,erection with GI clamps and brackets with adequate number of supports for pipes every 2.5 mts interval and at bends for Insulated refrigerant pipe for exposed areas etc , FALSE CEILING WORK , Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. , wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint , all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum moisture resistant board. (Make : Gproc , L Strong , Armstrong) , ELECTRICAL WORKS: , MV Panels VRF/VRV OUTDOOR PANNEL-1 , Supply, installation,Testing and Commissioning of 3 phase and Neutral 415V, 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tank process and painting with Epoxy powder coating. , The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. , The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. , The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The PCC shall have at least two spare cubicles of the maximum rating. The size of all Panel Mounting Meters shall be 96X96mm. , The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely. , M.V.PANEL ( OUTDOOR ) -VRF OUTDOOR UNIT , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , BUSBARS : 800A, TPN Aluminium busbars – 1set , Metering for Incomer , Phaseindicating lamps - 1 set withtoggle switch , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-800A) with selector switch - 1 set , Multifunction Meter -1Set , 800/5A, CL-1, 15VA CTs with resin cast- 3Nos. , Outgoing Feeders :- , 63A TP 16KA MCCB As Outgoing Feeder - 18 Nos , Earth bus bar with GI Strip , MV Panels VRF/VRV OUTDOOR PANNEL-2 , Supply, installation, Testing andCommissioning of 3 phase and Neutral415V 4 wire Free Standing Floor mounted outdoor type weather proof double door with canopy on top MV panel made out of 3mm thick CRCA/Galvanised steel enclosurefor main frame and 2mm thick partitions for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable ratingTPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMCbarriers and color coded with Heat shrinkable sleeves. The Metering shall beprovided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. Outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose. , The PCC shall have at least twospare cubicles. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely.ACBs shall have built-inAll ACBs shall be provided with Digital type Ammeter of suitable range along with CTs. All ACBs shall be provided with ON/OFF/TRIP indication lamps and shunt trip coils. All MCCB/ACBs of rating 160Aand above shall be with Micro processor releases All MCCBs below 160A shall be with adjustable thermal magnetic based releases. All MCCBs shall be with spreader links and rotary handle. All MCCBs shall be over load & short circuit releases withIcu=100% Ics. All CTs/CBCT shall be resin cast type. All Controlling wiring shall be FRLS cables, all the bus bar sleeves shall be Heat shrinkable kits.Panels shall have form 4b/form 3b construction as per the requirement. ACBs shall conform to IEC 60947 (part 1&2), shall be suitable for rated system voltage 690V, Insulation voltage 1000V and Impulse withstand of 12KV. , For MCCB with Microprocessor based release : A common indication LED for internal temp/ fault/alarm . MCCB should have in-built feature of logical selectivity by which it can give a time delay of 50msec between upstream and downstream MCCB The microprocessor based release should have the following settings: • Overload Settings: 0.4 to 1 times of Ir • Short Circuit Settings: 1.25 to 10 times of Ir. • Earth fault Settings: 0.2 to 1 times of In. • Neutral protection settings: 0 – 50% – 100%Ir. • Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction. • MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) • The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material. , OUTDOOR MAIN PCC PANEL , Incoming : , Incoming : 800A FP 50KA EDO ACB with Microprocesser Based releases for Overload, S/Cand earth fault- 1 set , Busbars :800A TPN Aluminiumbusbars - 1 set , Outgoings : , 63A TPN, 16kA,Moulded Case Circuit Breakerand Electromagnetic based protection release having adjustable over load, short circuit and earth fault protection.- 20 No. , Metering : , 0-500V Digital Voltmeter withselector switch and Fuses - 2 sets , 0-800A Digital Ammeter with CTs ofratio 800/5A,Class 1 Accuracy and15VA burden and selector switch - 2sets , LED Phase indication lamps with individuals Fuses and control withtoggle switches- 2sets , CT Operated Load Manager with RS 485 port ( Similar to EM-6400) – 2sets , Suitable Earth strip at bottom of the panel of GI Strip , Supply, Installation, Testing and Commissioning of following size 1.1 KV Grade Aluminum / Copper conductor XLPE insulated PVC sheathed armoured cable and shall be laid on cable traywith all installation materials. the cable shall conform to IS 7098 / part-I. , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , Supply, Installation, Testing and Commissioning of following size ELECTRICAL TERMINATIONS WITH SINGLE COMPRESSION GLANDS / LUGS: , 4Core X 10Sqmm (Copper)(Armoured) (for 20HP ODU ) - 27Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 28TR AHU ) - 1Nos , 4Core X 6Sqmm (Copper)(Armoured) (for 8KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 52TR AHU ) - 1Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 12KW HEATER ) - 1Nos , 4Core X 16Sqmm (Copper)(Armoured) (for 42TR AHU ) - 4Nos , 4Core X 10Sqmm (Copper)(Armoured) (for 15KW HEATER ) - 4Nos , SITC of GI Earthing for equipment , 8 SWG G.I. Wire , SUBHEAD-IVX : POWER WIRING : , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (8 + 36), Double door , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 12 way (4 + 24), Double door , 8 way (4 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A Three Pole MCB 16 kA , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box,front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and fixing of factory made 20A, 1Ph Metalclad socket with plugtop &20A SPMCB in MS box including all fixing accessories , Supply and fixing of factory made 25A, 1Ph Metalclad socket with plugtop &25A SPMCB in MS box including all fixing accessories , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earth metal enclosed plug top alongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections, testingand commissionining etc complete as required. , Supply,erection,testing and commissioning of the following switchsockets with anodised G.I. Box, Stainless steel front plate and fixing screws etc . , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch. , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in and includingsuitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wireinand including 25mm diaPVC Conduit(For 16A Sockets). , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wireinand including 25mm diaPVC Conduit(For AC Sockets). , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinand including 25mm diaPVCConduit. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways , Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in existingMS/PVC conduit / Floor race way including all necessary interconnections etc complete. , 2runs of 2.5Sq.mm wires with 1run of 2.5 Sq.mm wire in existingPVC Conduit(For 6A Sockets & Switch boards),ferrules incliding all labour charges etc., complte.. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wiresin existingPVC Conduit(For 16A Sockets), ferrules incliding all labour charges etc., complte.. , 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wiresin existing PVC Conduit(For AC Sockets), ferrules incliding all labour charges etc., complte.. , 4runs of 6Sq.mm wires with 2run of 6 Sq.mm wiresin existing PVC Conduit. for run of mains, ferrules incliding all labour charges etc., complte. , 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wireinexistingPVCConduit.for run of mains, ferrules incliding all labour charges etc., complte. , 4 X 16 sq. mm + 2 X 16 sq. mm earth wire in existin PVC / Floor raceways for run of mains, ferrules incliding all labour charges etc., complte. , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standard length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , 100 mm widex 50 mm Height , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XV : SHOP ELECTRIC: , Supplying and fixing 20A, 415V, TPN industrial typesocket outlet with 4 pole and earth metal enclosed plug top alongwith 20A C Curve,4 P MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 32A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 32A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supplying and fixing 63A, 415V, TPN industrial type socket outlet with 4 pole and earthalongwith 63A C Curve, TP MCB in sheet metal enclosure on surface/recess with chained metal cover for the socket outlet and complete with connections ,testingand commissionining etc complete as required. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 10Sq.mm , 4C X 16Sq.mm , 3.5C X 25Sq.mm , 3.5C X 35Sq.mm , 4C X 50Sq.mmCu Armoured Cable , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick G.Isheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thickGI covers. , 600 mm widex 50 mm Height , 450 mm widex 50 mm Height , 300 mm widex 50 mm Height , 150 mm widex 50 mm Height , Providing and fixing of maintenance free earthing which consists of 40mm Dia, standrad length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following size strips including all necessary inter connections with earth station and equipments. , 50 X 5 mm Hot dip GI strip , 25 X 5 mm Hot dip GI strip , Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 12 way (8 + 36), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 250 A, 35KA 4P MCCB , 200 A, 35KA 4P MCCB , 63 A, 4P RCBO , 100 A, 4P ,25ka MCCB ( , 125 A, 4P ,25ka MCCB ( , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears , All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , USER EQUIPMENT PANEL , Incomer , 630 A, 50KA, 4P , ACB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 9 Nos , 125A ,25KA TP, MCCBs - 3 Nos , 100A ,25KA TP, MCCBs - 3 Nos , 63A ,16KA TP, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main LDB , Incomer , 250 A, 35KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTsof ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , Main PDB , Incomer , 630 A, 50KA, 4P , MCCB, Should be supplied with Microprocessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 200A ,35KA TP, MCCBs - 5 Nos , 63A ,16KA TP, MCCBs - 2 Nos , Surge Protection Device - 1 No , Bus Bar : 630 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-630A Digital Ammeter with resin cast CTsof ratio 630/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , COMPRESSOR PANEL , Incomer , 250 A, 35KA, 4P , MCCB Should be supplied with Microprcessor basedS/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 160A ,25KA TP, MCCBs – 3 Nos , 63A ,16KA TP, MCCBs - 1 Nos , 40A ,16KA TP, MCCBs - 1 Nos , Surge Protection Device - 1 No , Bus Bar : 250 A TPN Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-250A Digital Ammeter with resin cast CTs of ratio 250/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , SUBHEAD-XVI :TELEPHONE AND LAN : , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as required for Telephone etc., , Supply and laying of 25mm dia, heavy gaugePVC . conduit concealed in wall/ ceiling/ floorand drawing of 12 SWG GI Wireas fish wire for laying of LAN Cables at a later stage and supply of all fixingaccessories such as junction boxes, conduit bends, etc., complete as required. , Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and fixing screws. , Supply,Installation,Testing and commissioning ofRJ 45 socket(FOR LAN) with flush mounting G.I. box, with front plate and fixing screws etc complete. , Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wireconforming to DOT Specifications in already laid PVC Conduit including necessary interconnections. , Supply and laying of Cat 6 LAN cable conforming to DOT Specifications in already laid PVC Conduit Floor Race way including necessary interconnections. , Supply and laying of 10 Pair0.5 sqmm armoured copper conductor cable cable conforming to DOT Specifications in existing cable trench /Floor Race way including necessary interconnections. , Supply and installation of100 pair Krone connectors inMS junction box complete as required. , Supply and installation of50 pair Krone connectors inMS junction box complete as required. , Supply and installation of20 pair Krone connectors inMS junction box complete as required. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XVII :UPS WIRING : , Supply and fixing of2 Nos of 6/16A, 5Pin Socket outlet with 2Nos ofswitch of 16A ratingincluding Modular G.I Box, Front Plate and also including all fixing accessories etc complete. ( For UPS Socket) , 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch including Modular G.I Box, Front Plate and also including all fixing accessories etc complete. , Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCBdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs andincomer ) as required . (Note : Vertical type MCB TPDB isnormally used where 3 phase outlets are required.) , 4 way (4 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, molded case circuitbreaker (MCCB), having a breaking capacity 25 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 200A 4P MCCB, 35 kA , Supplying and fixingof following rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , 63A 4P MCB 10 kA , 63A TPN MCB 10 kA , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator). , 8 way (8 + 24), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 63 A , Supplying and fixingof 6A to 32A rating 240/415V, 10kA, C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete. , Single Pole , Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copperconductor, single core cable in surface/ recessed medium class PVC/MS/Floor race wayas required including necessary interconnections etc complete. , 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire , 4Runs X 10 sq. mm + 2 X 6 sq. mm earth wire in existing PVC / Floor raceways /MS Conduit , 4Runs X 16 sq. mm + 2 X 10 sq. mm earth wire in existing PVC / Floor raceways , Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired including excavation in all types of soil. , Supplying and laying following copper strip at 0.50 metre below ground as strip earth electrode, includingconnection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets(Jointing shall be done by overlapping and with 2 setsof brass nut bolt & spring washer spaced at 50mm). , 25 mm X 5 mm copper strip , 50 x 5 mm copper stripbelow ground. , Supply and Installationof 300 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply and Installationof 150 x 38 mm heightG.I Floor raceway including supply and installation ofJunction Boxes ,bends and fixing accessories etc complete.The scope also includes civil work for installation of Raceways i.e chipping of flooe wherever required and also laying of sand and cement mortar for alignment of Floor raceways etc complete.The minimum thickness of the floor raceways and junction boxes shall be 2 mm (Make : Legrand ) , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , UPS INPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P, MCCB Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 100A ,25KA 4P, MCCBs - 3 Nos , Surge Protection Device - 1 No , Bus Bar : 200 A TPN(100%)Alluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , LED phase indication lamps with toggle switch -1set , UPSOUTPUT PANEL INDOOR , Incomer , 200 A, 35KA, 4P , MCCB, Should be supplied with S/C, E/F, O/CProtection.(70 - 100% Plug setting) – 1No , 2A, controlMCB - 3 Nos. , Outgoings : , 63A ,10KA 4P, MCCBs - 5 Nos , Bus Bar : 200 A TP+NAlluminium Bus Bar-1 Set , MeteringIncomer : , 0-500V Digital Voltmeter with selector switch andMCB-1set , CT Operated Load Manager (similar to EM-6400) - 1 No , 0-200A Digital Ammeter with resin cast CTsof ratio 200/5A Class 1 Accuracy and 15VA burden and selector switch -1set , Surge Protection Device - 1 No , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 4C X 50Sq.mmCu Armoured Cable , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 35 sq. mm and upto 95 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 35 sq. mm and upto 95 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Above 35 sq. mm and upto 95 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 4C X 50Sq.mmCu Armoured Cable , SUBHEAD-XVIII : SPECIAL EARTHING : , Providing and fixing of maintenance free earthing which consists of 65 MM Dia ,2.5mtr long electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying under ground/above ground offollowing size strips including all necessary interconnections between earth station and equipments including earth excavation, back filling, intermediate supports for strips as applicable and directed by engineer in charge. , 25 x 3 mm copper strip on DMC insulators , 25 x 3 mm copper stripbelow ground. , 50 x 5 mm copper stripbelow ground. , Supply and fixing of Static Discharge Handles made out of 40 mm dia Copper rod 600 mm Long fixed on wall with brass spacers and connected to 25 x 3 mm copper strip by brazing. , Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , 50mm Dia , SUBHEAD-XIX : LIGHTNING PROTECTION : , Providing and fixing of maintenance free earthing which consists of 40mm Dia ,standrad length (as per Equipment Supplier ) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancingcompound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and laying of following sizestripsincluding all necessary inter connectionsbetween earth station and equipment. supports for strips as applicable and directed by engineer in charge. , 32 X6 mm Aluminiumstrip conductor with DMC Insulator Supports , 50 X 5 mm GI strip conductor including excvation and back filling. , 25 X 5 mm Hot dip GI strip , Supply and installation of vertical air termination with 100mm dia copper hollow sphere with spikes, fixed on 1500mm length 50mm dia Class C GI pipe including all fixing accessories. , Providing and fixing of Test links for Lightning protection system. , SUBHEAD-XX: FIRE ALARM SYSTEM : , Supply, erection, testing and commissioning of Intelligent AddressableFire Alarm Control Panel(a minimum of 159 detectors/ 159 modules per loop )with Network Communication Module expandable to 2 loop, to monitor loop Devices located in allfloor with dual stage alarm facilities,built in buzzer,built in NAC Circuits & RS 485 port on CPU boardwith optional net work software connectivity, fire/fault indicators, audio-visual signals, battery, battery charger, central processing unit,80 character display unit,fibre optic converter and networking card etc complete in all respects . , 2 - Loop Panel ( One Loop for Integration ) , Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches etc complete. , Supply, Installation, Testing and commissioning of Online UPS of 1 KVA capacity with built-in SMF Batteries (12V 7Ah X 3nos) for battery back up and regulated AC supply to the FAS. , COMIBINATION/MULTI SENSOR DETECTORS(Photoelectric + Heat Sensing) , Supply, fixing, testing and commissioning of Addressable anloguetype multi sensor detectors (Photo electric + Heat sensing) with dual chamber, solid state design,Rotatable DIP Switch Setting indicating lamp, mounting base etc. . , Supply, fixing, testing and commissioning of Response Indicators with all required accessories etc complete. , Supply, fixing, testing and commissioning of Addressable anloguetype Beam Detector with transmitter and receiverincluding short circuit isolator including connections with remote test features etc complete. Range 100 Mtr , MANUAL CALL POINTS: , Supply, erection, testing and commissioning of Addressable analogue typemanual call point for indoor installtion. , Supply, Installation, Testing and commissining of Addressable analogue type manual call point stations weather proofwith 1500 mm Length ISMC 100 standing Post. , FAULT ISOLATION MODULE: , Supply, fixing, testing and commissioning ofFault Isolation module. , Supply, installation, testing & commissioning of addressable fire control module complete as required. , Supply, installation, testing & commissioning of addressable fire Monitormodule complete as required. , CABLE: , Supply, laying , testing and commissioning of 1100 V grade FIRE RESITANCE LOW SMOKE PVC insulatedcopper conductor control cables as per specification. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid on cable tray /to be clamped to wall including supply and fixing of clamps etc complete. , Armoured Twisted pair2Cx 1.5 sq. mm. shielded FRLS insulated copper conductor cable to be laid in cable trench including excavation and backfilling. , 3 core x 2.5 Sq.mm armoured sheilded twisted pair copper conductor cable on cable tray/on wall including clamping etc complete and including cable end termination with double compression weather proof cable glands and copper lugs. , Supply and Installtion of 12 Way Elmex terminal powder Coated junction Boxincluding all terminations andNecessary Glands. , Supply, Installation, Testing and commissioning of Weather proof siren to be operated on Single Phase 230 V, 50 Hz ,A.C.Supply with a range of 2/3 km distance including fixing clamps and accessories.complete. , Supply, laying of 50mm dia, class-B GI pipe including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. , Supply and laying of of 6 core 9/125 micro meters armored single mode optical fiber cable with suitable dia HDPE pipe (1300nm wave length) including splicing & terminations and laid in ground at 750 mm below ground including excavation andsand, brick protection and refilling of earth and cable route markers at every 50 meters intervals. 6C SM ARM-OFC - 6 C Armoured Single Mode Optical Fiber Cable networking card and fibre optic converter etc., complete. , Supply and laying of 25mm dia, 16 SWG black enamelled M.S. conduit on wall surface/ ceiling/ floor including all accessories such as junction boxes, conduit bends, etc., complete as requiredduly coated with two coats ofred colour enamel paintetc., complete. , SUBHEAD-XXI :FIRE FIGHTING SYSTEM : , Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : , Single headed Gunmetal , Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : , 80 mm dia , 150 mm dia , Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : , 80mm dia , 150mm dia , Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : , 80mm dia , 150mm dia , Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : , Gun Metal , Supply, installtion, testing and commissioning off Hose Box to accommodate 2sets of CP hoses of 15 mtr length each and with 1 pair of Male and female coupling, and one branch pipe with nozzle. The cabinet shall be made of 16 SWG MS Sheet with double door glass front and painted with Scarlet Red colour of size 30x24. , Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : , Gun metal , Supply, Installation, Testing and Commissioning of Swinging type fire hose reel drum of Rubber hose 30mtrs length. , Supplying and fixing of fire brigadeconnectionofcast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : , 4 way - 150 mm dia M.S. Pipe , Providing, laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, as supports, anticorrosive treatment with coaltar/asphalt/bitumen tape as per IS 10221, refilling the trench etc. of following sizes complete as required. , 150 mm dia. Pipe , 80 mm dia. Pipe , 50 mm dia. Pipe , Supply, errect, jointing, testing and commissioning of heavy class MS pipes (as per IS-1239). The pipes being fixed on to the wall or suspended from the ceiling/ truss with angle iron supports complete with bends, tees, flanges and with all other required accessories including painting of the pipeline with two coats of approved enamel paint over a coat of primer etc. complete. , 150 mm dia. , 100 mm dia. , 80 mm dia. , 65 mm dia. , 50 mm dia. , 40 mm dia. , 32 mm dia. , 25 mm dia. , Supply and installation , Testing andcommissioingofapproved make 15mm orifice quartzoid bulb pendent type sprinklers,68°C rating, recessed , Supply and installation, Testing andcommissioingofapproved make 15mm orifice quartzoid bulb side wallpendant type sprinklers,68°C rating. , Supply installation and fixing of flow switchesin the followingPipe line with1NO+1NC Contacts , a)150/100mm dia , Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , In ordinary soil. , Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia , Hard rock (blasting prohibited) , Ordinary rock : , Construction valve chamber 1.8 Mtrs x 1.2 Mtrs x 1.2 Mtrs in first classbrick (table moulded) masonry in CM 1:6 on PCC bed to 100mm thick plastering with CM 1:4 internal and providing CI Cover with stiffness lifting arrangement frame work etc. complete with providing anticorrosive paint on both side for steel works.Cover should be in two halfs fixed to frame work by means of hinges. , Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : , 300 mm dia. R.C.C. pipe , Supply, laying, jointing, testing and commissioning heavy class M.S pipe (as per IS-1239) in Pump roomwithMS supports including two coats of red oxide and two coats of Red coloure enamel paint . Rate quoted shall include for necessary specials like long radius bends, tees, including cutting, welding/ flanged joints with necessary washers, nuts, bolts etc., complete. , 250 mm dia. Pipe , 200 mm dia. Pipe , 150 mm dia. Pipe , 100 mm dia. Pipe , 80 mm dia. Pipe , Supply, Installation,Testing and Commissioning of air cussion vessel ofcapacity 250 litreswith air releasevalve and ball valve. , Supply,Installation,Testing and Commissioning of PN 16Sluice valves with gateof the following sizes. , a) 250mm dia , b) 200mm dia , c) 100mm dia , Supply,Installation,Testing and Commissioning of PN 16Butterfly valves of the following sizes including flanges and hardware ,nuts and bolts etc complete. , a) 200mm dia , b) 80mm dia , Supply, Installation, Testing and Commissioning of CI Non Return valves of the following sizes. , a) 200mm dia , b)80mm dia , Supply, installation, testing and commissioning of approved make brass Y strainer with necessary flanges which should include nuts, bolts, washers, gaskets. , a) 200 mm dia. , c) 100 mm dia. , Supply,Installation,Testing and Commissioning ofelectrical control panel for diesel engine, main motor and for jockey pump comprising of following. , Incoming : 800A,50KA TPNMCCB - 1SET , 800A TPN aluminium busbars - 1set , Outgoings: , Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , (with built in single phase preventor) and ON/OFF/TRIP , indication lamps for motor-2set , Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets , Diesel Engine Control , Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification , Supply installation testing and commissioning of Instrumentation Board on type pressure gauges for pumps in delivery line and common delivery header , Supply fabrication and erection of MS angle supports for Pipe lines , Supply and fixing of G.M. ball type valves Conforming to IS , a) 25mm dia , b) 15mm dia , Supply, Installation, Testing and Commissioning of Pressure Switches. Make: Indfoss/Donfoss , Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 lpm at 70 m Head with 70% of Pump efficiency. , Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 70 m Head , Supply, Installation of following Fire extinguishers & accessories: , CO2 6.5 kg capacity trolley mounted , CO2 22.5 kg capacity trolley mounted , DCP 5 kg capacity (potassium bi-carbonate Uria reaction) , Water buckets with stand , Sand buckets with stand , Showels , Fire Beater , Fire gong/ hand siren , Ceiling Hook , Supplying, installation, testing & commissioning of 1000 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying, installation, testing & commissioning of 1500 MM sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. , Supplying Installation Testing & Commissioning of Ceiling Mountedexit sign/emergency lighting unit uses high-performance led lamps. , Supply installation testing and commissioning of900LPM,35mtrs head Booster pump with Suitable HP 2900 RPM Electrical motor and coupling as per TAC regulations with necessary accessory including base plate of MS channel and suitable reinforced CC foundation with nuts andbolts , Supply, installation, testing and commissioningof weather proof type MPCB box made out of 2mm thick CRCA sheet including painting with epoxypowder coating for Suitable HPBooster pump motor. The box shall be suitable for terminating AYFY cable ofsuitable angle frame work of 450mm height on a PCC pedestal including all materials Outgoings : DOL starter for 15HP with MPCB and contractor, over load relay, single phasing preventor and ON/OFF/TRIP , SUBHEAD-XXII: WATER COLLERS , Supply and fixing of 40 (cooling)/ 80 (storage) ltrswater cooler with water purifier (RO system) and voltage stabilizer etc. complete. , SUBHEAD-XXIII :LIFTS : , Supply, erection, testing and commissioning ofMachine room less gear less 1000Kgs Goods liftwith a speed of 0.75 meters per second,suitable for (Ground + 2floors) floors operation with 3 phase ACVVVF drive of suitable HP to operate on 415 volts 50 HZ with base including 1100X 1300X2300 mm car made of all stainless steel body, heavy duty cabin suitable for one number car entrance and landing entrance doors ( Center operated doors ) , SS hairline finish , with clear opening of 800x2100mmn height suitable for simplex selective and collective operation with or without attendant including call register and other parameters as per specification , SUBHEAD-XXIV : EOT CRANES , Design, Manufacture, supply , erection, testing and CommissioningofTandem operator (1 set consist of 2 nos of cranes)DoubleGirderNon FLPEOT Cranewithall speeds VVVF drivecontrol and micro speed arrangement for hoist, CT & LT and confirming to IS 807/IS 3177 /4137cand other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores / building, where to be installed etc., movement of material to work spot including the cost of paint as required loaded testing at factory and at site. The crane shall be designed for earthquake and sesmic qualification.Span to be measured by the the Bidder at Site and it shall be its sole responsibility to provided Spansuitable . Design drawings and list of materail to be submitted to department duly approved checked by Govt., agency/ reputed technical institute as approved by department. VVVF drive controls with along travel andcross travel movement and with pendent control opeartion as per IS807 &IS3177(includingfestool cable, 60 lb rails, third party inspection, transportation, design proof check)Double Girder Box Type. 25% overload ,Duty class- III, head Room 2.5mtr,side clearence 300.indoor operation.AC Control Supply , Floor operated via pendant push button,All drives should be provided with alternative parallel path with DOL starter for Main Speed only , MOTORS- Conformingto IS 325-1978& 900-1965, , GEAR BOX- Electro Hydraulic Thrusters type,3Ph, 440V, A.C. Conforming with IS 3938 - 1983 , WIRE ROPE- 6X 36 Cont. Hempcore(IS 2365-1963) , Rope Drum- made from Seamless/ms rolled , Hook- Forged Material EN-3A , WHEEL ASSEMBLY- Made from forged steel- Double flange hardened to BHN 275 Conforming with IS 807-1976. , BEARING- All bearings are of anti Friction Ball/ Roller Conforming, with IS 6455-1972 , COUPLING- AlI Couplings will be Geared Coupling , SHAFT-All Shafts will be of EN - 9 , RESISTANCE BOXES- AlI resistance boxes will be stainless steel, Wire grid and 15 min. Rated heavy duty, (IS 1822 -1967 ) , LIMIT SWITCH- Rotary Limit Switch for Hoisting & Lever Type for L.T &C.T. Conforming with IS- 3936 - 1983 , PANEL BOXES - All panel boxes will be of steel febricated , CONTROL TRANSFORMER- 750 VA, 44OV / LLOV. , POWER CONTROL CABLE -Sheet Metal housing, DustlVermin Proof having BCH/Siemens Contactors & Overload ReIays BCH time delay Relay , PAINT- Two coats of Red Primer & Two coats of Golden Yellow. , Fullplatform on driving side & two small platform on non driving side.(Monkey ladder &side railing shall be provided by civil) , PART- I : SUPPLY , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 5 Ton capacity cranes) 5 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 8.5 mts. Bay length: 73± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of material for Gantry Rails section 60 lb of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 5 ton capacity crane as per above BOQ EOT 1.1) , Supply of Non-FlameproofTandem Operated ( 1 set consist of2 Nos of 2 Ton capacity cranes) 2 Ton capacityDoubleGirder Crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 31774137 and other relevant IS standards of the latest revision.All drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs.to bechecked as per site condition ± Lift: 5.5 mts. Bay length: 17.5± 0.5 mtr (to bechecked as per site condition ± , Crane operating speeds , Main speed Micro speed , Main hoist:2.5m/min 0.25m/min , Cross travel :10m/min1.0m/min , Long travel: 15m/min 1.5m/min , Micro speedfor all motions : 10% of main speed through VVVF drives. , Provision of inching is to be incorporated in the drives. , Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures etc completeas per site condition (For 2 ton capacity crane as per above BOQ EOT 2.1) , Supply of material for Gantry Rails section 50 mm sqr barof prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept as per site condition(For 2 ton capacity crane as per above BOQ EOT 2.1) , Part-II: - ERECTION, TESTING AND COMMISSIONING , Erection, testing and commissioning ofNon FLP EOTTadem Opereated followingDouble Girder EOT Cranesincluding loaded testing and others mentioned in item S.No.EOT-1.1 to EOT-2.3 of Part-I as per the relevant IS standards and as mentioned in the technical specifications. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Cranes of 5 Ton capacity( 1 set consist of2 Nos of 5 Ton capacity cranes) mentioned in Items .No.EOT-1.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:14.5 mts. ± 0.5 mtrs. Lift: 8.5 mts. Bay length: 73± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-1.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 60 Lb mentioned in item Sl No.EOT-1.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Erection, testing and commissioning ofNonFlameproof Tadem Opereated Double Girder EOT Crane of( 1 set consist of2 Nos of 2 Ton capacity cranes)mentioned in Items .No.EOT-2.1of Part-I with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision.including loaded testingAll drives should be provided with alternative parallel path with DOL starter for Main Speed only. Span:17.5 mts. ± 0.5 mtrs. Lift: 5.5 mts. Bay length:17.5± 0.5 mtrto bechecked as per site condition ± , Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No.EOT-2.2 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete as per site condition. , Erection, testing & commissioning of Gantry rail section 50 mm sqr barmentioned in item Sl No.EOT-2.3 of Part -I with mounting arrangementand fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete as per site condition. , Supply of Test loads of 5 Ton along with Slings and D-shakles (Suitable for 5 Ton, loads of 5 ton -1 no, 1 ton-1 nos, 0.25 ton -1 nos , Supply of Test loads of 2 Ton along with Slings and D-shakles (Suitable for 2 Ton, loads of 2 ton -1 no, 0.5ton -1 nos , SUBHEAD-XXV : BOOM BARRIER: , Supply,Installation,Testing and commissioning of 6 mtr length Boom Barrier electromechanical hydraucally operatedopening and closing times can be adjusted between 3 to 6 seconds and speeds can be adjusted seperately through hydraulic adjusters in a closed circuit system optional emergency close option 2 seconds shall be available with 100% duty cycle with power supply unit,photo sensors,flashing lights on the boom ,push button for entry,exit & Remote control.This shall be along with safety features like Induction and safety loop etc with remote operating facility with remote control unit,along with 4 nos of photo cells with each boom barrier.The system shall be complete in all respects along with all fixing accessories and civil works , SUBHEAD-XXVI :ROADS/HARDSTANDING & DRAINS : , Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. , Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soils. , Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. , Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. , 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity. , Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.With rapid setting bitumen emulsion. On W.B.M / W.M.M. @ 0.4kg/Sqm. , Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. , Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). , SUBHEAD-XXVII :EXTERNAL WATER SUPPLY SERVICES: , Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. , 25 mm dia nominal bore , 40 mm dia nominal bore , 50 mm dia nominal bore , 100 mm dia nominal bore , Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : , 50 NB , Making connection of G.I distribution branch with G.I mainof folloeing size by providing and fixing tee, inclding cutting and threading the pipe etc. complete: , 25 to 40 mm nominal bore , 50 to 80 mm nominal bore , Providing and fixing gun metal non- return valve of approved quality (screwed end) : , 25mm nominal bore , 40 mm nominal bore , 50 mm nominal bore , Supply,erection, testing and commissiong of C.I Air release valves flanged end type with bolts,nuts and rubber insertions etc., complete andof following sizes: , 25mm nominal bore , 50 mm nominal bore , Supply and Fixing of cast iron pipe line Route Marker for water supply Network system , Borewells , Geological Survey by specialist Agencies and submitting the report for number of poit surved and yield available , Drilling and developing of 61/2 inch dia Bore Wells by DTH method in any type of soil, Conducting yield test as per V Notch method and submission of yield report, including filling of filter media clamps, MS Cover etc., complete. , a) 0-60 mtrs , b) 61-100 mtrs , c) 101-200 mtrs , Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm Dia. , Providing HDPE pipe PE-80 grade (12.5 kg/ sq.cm) of 63 mm OD for bore wells. , Supply, erection, testing and commissioning of 3 Cu.m/hr at 70 m head submersible pump set 3Phase-415V, 50 Hz, 2 HP/ 12 stages, 2900 rpm as approved by Engineer in charge at site.(As per depth of base) , Supply, erection, testing and commissioning of Gun metal Check valve (Non return valve PN-10) conforming to IS 778 with screwed ends type with bolts, nuts and rubber insertions etc., complete and of following sizes: , a)50 NB , Supply, erection, testing and commissioning of Brass / GM / Bronze Air Release valves with threaded ends of following sizes: , a) 25 NB , Supply, erection, testing and commissioning of pressure gauges with range of 0-10 bar along with isolation cock and pipe for bore wells. , Supply, installation, testing and commissioning of weather proof type box (IP-55) made out of 2 mm thick CRCA sheet including painting with epoxy powder coating. The box shall be consisting of star-delta starter suitable for 3 Cu.m/hr and 200 meters head pumpmotor with MPCB, contactor, overload relay, ON/ OFF push button. ON/ OFF/ TRIP indications. Ammeter with resin cost Cts and selector switch, Voltmeter with selector switch. The box shall be suitable for terminating suitable cable. The box shall be mounted on suitable angle frame work of 450 mm height on a PCC pedestal including all materials, complete. , Providing maintenance free Earth station with consisting of 40 mm dia pipe standard length (as per equipment supplier) electrode capsule, filled with earth enhancing compound, sealed at both ends and brazed lead for connection at one end, suitable for direct installation at site, at a depth of 2.5 mtrs. Bentonite compound (as per equipment supplier) upto a depth of 2.0 meters around the electrode capsule. Brick chamber & CI Cover complete. , Supply and laying of following size strips including excavation and refilling of each when laid in ground and with all fixing accessories when laid inside the building including all necessary interconnections with earth station and equipments. , a) 25 x 5 mm hot dip galvanized iron strip , b) 8 SWG GI Wire , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils , Supply, Laying, testing and commissioning of Medium grade G.I. Pipes conforming to IS 1239 Part - I including all necessary fittings etc., complete for sizes , a) 65 NB (Borewell to sump) , b) 50NB (Borewell) , c) 40NB (Borewell to sump) , d) 32NB , e) 25NB , Supply, Erection, testing and commissioning of Cast Iron Butterfly valves (Wafer type) (PN-10) above nd upto 50mm dia with necessary flanges, bolts, nuts etc., and gun metal gate valves from 40mm dia and below , a) 65NB(GM Gate Valve) , b) 50NB(GM Gate Valve) , c) 40NB(GM Gate Valve) , d) 32NB (GM Gate Valve) , e) 25NB (GM Gate Valve) , Constructing of Valve Chamber of size 750 x 750 x 1000mm deep comprising of 230mm thick brick walls in cement mortar 1:5 over a bed of 150mm thick PCC 1:4:8 alround beyond the masonry faces plastered with CM 1:3 mixed with approved water proofing compound as per manufacturers specifications, 13mm thick on internal, external, top surfaces, finished smooth with a floating coat of neat cement, providing and fixing painted light duty double seal CI frame and cover of size 600 x 450mm weighting not less than 52 kgs conforming to IS 1726 with locking arrangements, fixing the frame in RCC 1:2:4 including fabrication, form work, curing etc., complete all as specified and directed. , Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete (a) 50 to 80 mm nominal bore: , Providing and fixing gun metal non- return valve of approved quality (screwed end) :Vertical (a) 50 mm nominal bore . , Supply, laying and commissioning of following size 1.1KV grade PVC insulated flexible Copper conductor in the bore withall installation materials. The cable shall conform to IS 694 , a) 3C x4sqmm (copper ), pvc Flat Water proof cable. , Conducting water yield test without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. , Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. , 200mm clamp , SUBHEAD-XXVIII : EXTERNALELECRIFICATION , 11KV HT SWITCHGEAR INDOOR , Supply,Installation,Testing and commissioning ofthe following indoor floor mounted 11kv Rated VCB Panel in Metal Enclosure fabricated out of 14 swg sheet steelto be operated on 11KV,Three phase,50HZA.C Power supply .The panel is to be compartmentalised with individual compartments for Bus bars, Cable and CTs and Instrument and relay control Panel. The VCBshall behorizontal draw out single breakas per IS 13118.The short circuit fault level of the system shall be 350MVA- Indoor , 11 KV- H.TSWITCH GEAR PANEL - INDOOR , 11KV VCB panel withone noof1250A vcb -Indoor as Incomer and 3 Nos 800A VCB as out goings. , 11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 1250 Vaccum Circuir breakerasIncomer. , CONSTRUCTION - The Switch Gear Panel shallbe compartmentalised Designed with cubicles fabricatedout of High Quality Sheet Steel. The panels shall be designed having the Following Segregations separately. , a) Busbar compartment , b) Cable and CT compartment , c)) Instrument and Relay Compartment , The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals. , The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement. , SAFETYFEATURES: , a) Mechanical Interlock and earth switch for out goings , b) Door interlock in service position. , INCOMING VCB PANEL , 11 , KV, 1250A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch. , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 200-100- 5/5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-200A. , POTENTIAL TRANSFORMER: (3 No’s) Cast Resin , Ratio 11000 V/ rt 3 / 110 v / rt 3 , 100 VA, CI – 0.2 for Metering and 3 P for Protection and also with 2 numbers of Under Volage relays. , OUTGOING VCB PANEL , 11 , KV, 800A, 26.2 KA,Horizontal Draw out type Vaccum Circuit breaker withmotor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch.-Outgoing-4Nos , CURRENT TRANSFORMER: (3 No’s) Cast Resin , Ratio 75 /5 A, Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. , METERING: ( 1set) , 96 Sq.mm Digital Ammeter with selector switch Digital type 0-100A. , Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading. , INDICATION LAMPS: , 1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lampsfor RYB.-(1 set) , CONTROL SWITCHES/PUSH BUTTON , Bus Bar with 1250 Amps Copper- (1 set) , COMMON FOR SWITCHGEAR: , Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCBs for AC/DC Control - (1 set) , MS sheet enclosure suitable for Indoor installation withoutgoing cable entry.- (1 set) , RelaysIncomer ; Undervoltage relays 2 nos,IDMT relay ,TCH and Master trip relay and also with 12 window annunciator , Power Pack - 1 No with necessary Interconnections. , Supply andcommissioning of 11KV earthed HT cable of size3 c x300 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Supply andcommissioning of 11KV earthed HT cable of size3 c x185 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098- Part 2 - 1983 , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Above 120 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Above 120 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on cable tray as required. , Above 120 sq. mm and upto 400 sq. mm , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 300sqmm ( Indoor Termination Kit). , Supply, Installation, Testing and commissioning of 11 KVearthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 185sqmm ( Indoor Termination Kit). , Supply and Installation ,Commissioning of HT Straight through Joint Kit for 3 C x 300 Sqmm EarthedXLPE insulatedarmoured alluminium conductor cable. , Supply, Installation, Testing and commissioning of 1000KVA, 11kv / 433 v, 3 PHASE, 50 Hz, Dyn 11 ,outdoorANAN Resin cast dry typeTransformerwithon load tap changer, RTCC panel, AVR andHT Side marshalling box for termination of 11 kv grade , 3 c x 300 sqmm XLPEinsulated alluminium conductor screeened cable and LT side provision for connecting sandwich type of Alluminium bus trunking system of 1600 A capacityas per IS 11117 etc , LT SANDWICH TYPE BUS DUCT , Supply, Installation, Testing and commissioning of 415 V, 50 Hz, A.C, 1600 A, Three phase and neutral Sandwhich type Alluminium bus bars Bus trunking system with necessary fixing Clamps and Jointing accessories including all required horizontal and vertical bends, tees for outdoorApplicationIp -65( Transformer feeder Incomer ) .As p-er IS ; 8623 Part 1 & 2. , M.V.PANELS , Supply,Installation Testing Commissioning of following TTA PANEL.Supply, erection, testing and commissioning of 415V, 3 phase 4 wire 50 c/s Main LT Panel at Substation fully compartmentalized cubical type, as per the standards IEC61439-1&2 as tested assembly (TTA) ,tested for impulse voltage 8 KV,IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having required capacity extensible type FP bus bars of high conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35KA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, Form of separation shall be form 4b with metallic separation only entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of bus bars, interconnection, interlocking between feeders etc.,with indication lamps, push buttons necessary accessories, complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram including provision to be made for interfacing with BMS etc. complete as required, with incoming & outgoing cable entry from bottom/top and bus-duct entry from top, wiring with 2.5sq. mm. FRLS insulated copper conductor , cable alleys, PLC cable gland i/c providing following switch gears All ACBs should have Ics=Icu=Icw for 1 sec All MCCBs shall be rating for 25kA (Ics=Icu). All MCCBs above 63A should be provided with Copper Spreader Terminals Marshalling Bay To Be Provided for BMS Operation Approval shall be taken for each panel before fabrication. PLC based control with 100% hot redundant PLC arrangement with touch-screen LCD / LED display board (min. 8 Diag size)along with all accessories for complete automatic, manual andHMI controls & indication. Energy Management Software wth necessary cabling shall be in scope, nos. of breaker / Meters to be connect with energy management software shall be inform by Engineer In Charge. , MAIN MVPANEL - 1- Indoor , Incomer 1,3,4 : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 9 Nos. , RYB indicating lamps - 3 sets , Voltmeter (0-500V) with selector switch - 3 sets , Ammeter (0-1600A) with selector switch - 3 sets , 1600/5A, CL-1, 15VA CTs with resin cast- 3 nos. , A Single CT with ratio of1600 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. ( For 3 Nos of Incomers ) , Bus Coupler : 3 Nos of 1600 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , Incomer 2 : 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 1250A, 3P, 50KA, EDO ACB - = 2 Nos , 800A, 3P, 50KA, EDO ACB - = 3 Nos , 630A, 3P, 50KA, EDO ACB - = 3 Nos , 250A, 3P, 35KA, MCCB, -=1 No , 200A, 3P, 35KA, MCCB, -=1 No , 160A, 3P, 25KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 Nos , Surge Protection Device - 1 No , 63 A, 3P, 16KA, MCCB, -= 1 No and also with 20 A TPNMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required24 hors clock settings. , Bus Bars : 1600A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , MAIN BUILDING PANEL- INDOOR , Incomer: 1 No of 1250 A, 4P. EDO ACB, 50KA,shallbe supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. , 2A, control MCB - 3 Nos. , RYB indicating lamps - 1 sets , Voltmeter (0-500V) with selector switch - 1 sets , Ammeter (0-1250A) with selector switch - 1 sets , 1250/5A, CL-1, 15VA CTs with resin cast- 1 nos. , A Single CT with ratio of1250 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. , Outgoing , 630A, 3P, 50KA, EDO ACB - = 2 No , 630A, 3P, 50KA, MCCB - = 2 Nos , 250A, 3P, 35KA, MCCB, -=3 Nos , 200A, 3P, 35KA, MCCB, -=2 Nos , 63A, 3P, 16KA, MCCB, -=3 No , Surge Protection Device - 1 No , Bus Bars : 1250A, 3Ph, 4 wireTPN , 50Hz, aluminium bus bars , Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. , Earth Bus; To be provided at the bottom of the Panel of Gi Strip , APFC PANEL INDOOR TTA PANEL - 300KVAR , Supply,Installation,Testing andCommissioning of APFC PANEL with Automatic power factor control relay and with 2 nos of 50 kvar capacitor banks and 25 kvar capacitor banks 8 nos with the following incoming and out goings.. The Panel is to be installed in Indoor. The panel is to be supplied with necessary power and control wiring required for the automatic operation of Power factor control. , INCOMER , 630 A, 4 P , 50KA MCCB with O/c, S/c,E/f Protection Microprocessore Relay Unit , 2A, control fuse - 3 Nos. , RYB indicating lamps - 1 set , Voltmeter (0-500V) with selector switch - 1 set , Ammeter (0-630A) with selector switch - 1 set , 630/5A, CL-1, 15VA CTs with resin cast- 3 nos. , Outgoing , 125 A, 3P, SDF , - 2No , 63 A, 3P, SDF , - 8 No , Bus Bars : 630A, 3Ph, TPN, 50Hz, aluminium bus bars , Metering Instruments ; Multi Function Meter in the Incomer and SDFon , off , TRIP Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps , Earth Bus; To be provided at the bottom of the Panel of copper , The panel is to be supplied with Required capacity Capacitor Banks as per BOQ quantity and also with required capacity over load relays,contactors ,Switch disconnecting fuses and also with APFC relay control wiring for manual and Auto operation. , EARTHING , Providing and fixing of maintenance free earthing which consists of 40 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Providing and fixing of maintenance free earthing which consists of 65 mm Dia, 3 mtr length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Bentonite compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil. , Supply and fixing of following earth strips/ conductors.The scope incudes supply and fixing of copper lugs wherever found necessary, brass bolts, nuts and washers for fixing arrangement etc., (from earth station to main panel). , 50x5 MM G.I.Flat , 25 x3 MM GI Flat , 50 x 6MM Copper Flat , 6SWG G.I.Wire , Cable Trays , Supply and fixing of following size GIPerforated type cable tray made out of 2mm thick sheet including MS supports for fixing the tray, anchor fasteners etc complete as required.Including with GI covers. , 600mm wide , 300mm wide , SAFETY ITEMS , Supply, Installation, Testing and commissioning of the Follwing Safety itemsas per standrads and specification. , Fire Extinguishers- 5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn , Rubber Mats 11 KV , 2 Mtr x 1 Mtr , Rubber Mats 415 V , 2 Mtr x 1 Mtr , Shock treatment Chart with frame and glass , First Aid Box , Sand Bucket with stand with 3 Nos of buckets and also with canaopy. , 415 V Danger Boards , 11 kv Danger Boards , Single Line Diagram with frame and glass. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor cable. The cable shall conform to IS 7098/ Part-II. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , Copper armoured control cables , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. , Upto 35 sq. mm , Above 35 sq. mm and upto 95 sq. mm , Above 95 sq. mm and upto 185 sq. mm , Above 185 sq. mm and upto 400 sq. mm , Providing Indoor ordinary end terminations for thefoollwing 1.1 KV grade XLPE insulated armoured alluminium conductor cables with compression type steel gland, Bi-metallic lugs using crimping tool, Insulation tape, Identification tags etc., including end termination and Earthing of Gland with 8SWG GI Wire. , 3.5C X 400Sq.mm , 3.5C X 300Sq.mm , 3.5C X 240Sq.mm , 3.5C X 185Sq.mm , 3.5C X 150Sq.mm , 3.5C X 95Sq.mm , 3.5C X 70Sq.mm , 3.5C X 50Sq.mm , 3.5C X 25Sq.mm , 4C X 16Sq.mm , End terminations of Copper armoured control cables including supply and fixing of crimping type copper lugs. , i) 4C X 2.5Sq.mm , ii) 7C X 2.5Sq.mm , iii) 19C X 2.5 Sq.mm , SUBHEAD-XXIX : AREA LIGHTING : , Supply and erection of steel stepped and swaged tubular poles of 9 mtr long(410 SP25) (1.5 mtr below ground) with base plate earthing studs 1.5 mtr out reach single /Double arm , FRP terminal Box 2 Nos of 40 mm Dia Class B G.I Pipe ,0.5 mtr Longfor incoming and outgoing cables including excavation in all types of soil ,PCC 1:2:4 ,PCC Pedestal with painting with black bitumen paint inside the coping for embedded portion and two coats of Zinc chromite primer and two coats of Alluminium paint externally for length above the ground.The pole shall be with FRP junction box consisting of 10A MCB.The wiring from Junction box to Light fixture shall be carried out with 3 Core 2.5 Sqmm Copper conductor flexible cable. , The Street Light Pole shall be fixed with 70W LED street Light fixture including supply of controlgear / driver and lamp(Make : Cat No.LR02-102-XXX-57-G2,WIPRO MAKE / CAT NO - Greenline V2 (BRP410) Philips/equivalent make.) , Supply and erection of 65 mm Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 :2 : 4PCC Pedestal etccomplete. The pole shall be with Junction box consisting of MCB.The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper conductor cable. The Pole shall be fixed withweather proof 72W LED ( Philips Cat No :BRP046 LED 30 CW MR S1 PSU GR/equivalent) Light fixtureincluding supply of driver and fixing clamps etc complete. , Supply, testingand commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II. , 4Core10sq.mm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required , Upto 35 Sqmm , Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. , Upto 35 Sqmm , ProvidingEnd terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductorcablewith compression type steel gland, alluminumlugs using crimping tool, Insulation tape, Identification tags etc.,complete , 4Core 10 sq.mm , Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments. , Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, weather proof MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powderpainted including earthing etc. as required. (But without MCB/RCCB/Isolator) , 4 way (8 + 12), Double door , Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. , 40A , Supplying and fixingof 6A to 32A rating 240/415V,10kA , C Curveminiature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. , Single Pole , Supply and Commissioning of thefollowing type Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall besupplied with lamps. The Catalogue Numbers refers to Philips Make. , 40 W Bulk Head Light Fixture Outdoor , (PhilipsCat No WT1 40W LED 7S NW PSU S1 PC /Equivalent as per approved makes)) , 150WLED Flood Light Fixture outdoor with alluminium die cast housing and also includind driver with fixing clamps etc complete , (PhilipsCat No BVP283 LED240 CW FG SY5NB 200W V1 /Equivalent as per approved makes)) , Installtionof Fluorescent/ Compact fluorescentlight fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. , SUBHEAD-XXX :SEWAGE DISPOSAL : , Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m in All kinds of soils. , Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. , PVC SWR PIPES , Providing, laying and jointing PVC/ SWR Pipes conform to IS:13592-1992 of Type-B on sand cushion at bottom and around the pipw and testing of joints etc. complete : , 100 mm dia PVC/SWR Single Socket , 150 mm dia PVC/SWR Single Socket , Providing and fixing square-mouth PVC gully trap conform to IS:13592-1992 complete with brick masonry chamber around as per standard design : , 100x100 mm PVC Gully trap with Sewer bricks conforming to IS : 13592-1992. , Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : , Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), With Sewer bricks conforming to IS : 4885. , Extra for depth for manholes : , Size 90x80 cm, With Sewer bricks conforming to IS : 4885 , Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design, With 20x20 mm square bar. , Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design, With common burnt clay F.P.S. (non modular) bricks of class designation 3.5. , Supply and positioning of ready made polyethylene septic tank of size 2.3M long 1.3M dia 16mm shell thickness with 2/3 chambers and 2Nos manholes of size 550mm dia and 100mm/160mm dia inlet outlet pipe and airvent pipe 50mm dia of make United Septic tank Design Reg.No 173352 Type-4 , SUBHEAD-XXXI : ARBORICULTURE : , TREE PLANTATION , Digging pits in all type of soils and refilling the same with the good earth (excavated / imported) & manure (organic manure/cow dung/sludge) in the ratio of 3:1 (03 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules, Thimet 10G @100-200 am/pit , (I) AVENUE / FLOWERING TREES / Palms , a) 1mts x 1mts x 1mts (L X W x D ) , b) Each pit to be added with 100gms of Thimet 10 g granule, to control termite attack. (Repeat the treatment after 06 months, if termite persists). Flooding the pit basin with water, dressing including removal of rubbish & surplus earth, if any, with all lead & lifts , c) Supply and plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of, 5-6 height, with a clear minimum height of 4-5 from basin / ground level, after plantation. Staking the tree sapling upto 3/4 height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with antitermite chemical , i) Phonix Palm , ii) Red Palm , iii) Golden Palm , iv) Fox Tail Palm , v) Areca Palm , d) Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period, for well establishment of tree sapling. Stacking to be continued till tree sapling attains the stem strength. Replacement of saplings casualties immediately , LAWM PLANTATION , a) Preparation of ground by trenching in all type of soils upto a depth of 30cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth (if needed). , b) Now rough dressing of trenched ground including breaking clods & flooding with water. , c) After 10-15 days removal of weeds / unwanted grass (motha etc) with roots & disposal of uprooted material, stone rubbish etc., with all lead & lifts. , d) Then fine dressing of ground. Spreading and mixing with the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 8:1 (08 part of stacked volume of good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. The area to be mixed with antitermite chemical / granules, Thimet 10G @ 100-200gm / sqmts. If termite persists repeat the treatment after 06 months by surface spreading the chemical. , e) Supply of grass and planting by dibbling the area including watering & maintenance of lawn for 30 days or more till grass forms a thick lawn cushion free from weeds , i) With Bermunda grass (15cm x 15cm apart) , ii) Carpet of grass turfing , iii) Supply & turfing of artificial lawn , iv) After ward maintenance of lawn area, green & weed free for 01 year with standard specification , SHRUB PLANTATION (SOLO) , Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 (05 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with antitermite chemical / granules thimet 10G @50-100gms / pit , i) Pit size 0.60mts x 0.60mts (Dia x Depth) , ii) Pit size 0.45 dia x 0.60mts Depth , b) Supply & plantation of shrub and / or rose sapling to pit, appropriate stacking & initial maintenance for 30 days. Replacement of sapling casualties immediately. , c) Afterward 01 year maintenance as per standard specification , SHRUBBERY PLANTATION - (SHRUBS IN GROUPS) , Digging beds in all type of soils and refilling the same with the good earth (excavated / imported) mixed with antitermite chemical / granules @100gm/sqmts) & manure (organic manure / cow dung / sludge) in the ratio of 5:1 by volume (05 part of staked volume of good earth & 1 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure , i) L X W X 0.60 mts depth , b) For roses, rose mixture @500gms / sq mts to be used additionally, before plantation , c) Termite treatment - Thimet 10G granules @100 gms / Sqmts , d) Supply & plantation of shrub sapling to pit, appropriate stacking & initial maintenance , e) Afterward 01 year maintenance as per standard specification , HEDGE PLANTATION , a) Digging trenches of approved / desired size of L X W (45-50cms) X D (30-60cm) in all type of soil. Refilling the trenches with good earth (excavated / imported) mixed with manure (cowdung / sludge / dump) in the ration of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth &8% stacked volume of manure. Fore Termite treatment add Thimet 10G granules @ 100gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation. , b) Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Sapling height & density as follows , i) Hedge with sapling height -0.45 mts to 0.60mts (After Plantation) , ii) Density - @07 Nos plants / running meters (staggered condition) , c) Maintenance the hedge by regular watering, trimming & pruning etc for 30 days initially. Replacement of sapling casualties immediately , d) Afterward maintenance of hedge length for 01 (one) year as per standard maintenance specification , GROUND COVER , Digging of ground cover marked area upto a depth of 30 cms in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cow dung / sludge) in the ration of 8:1 (08 part of good earth *01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100 gms/Sq mts. Flooding with water the entire area. Rough & fine dressing of the ground cover bed area and removal of weeds & unwanted vegetation & its disposal , b) Supply and plantation of approved / desired ground cover plant varieties, well established, fully grown, disease free and good foliage. Plantation density should be @36 ground cover plants / square metre, or less as desired or decided by site incharge. Maintenance of all the ground cover area for 30 days till the plants establish well. , c) Regular maintenance afterward for 01 year as per standard specification , FLOWER BED PREPARATION , Digging of FLOWER BED marked area upto a depth of 30 cms (Canna Beds - 60cms depth) in all type of soils. Refilling the same with (excavated / supplied) good earth mixed with manure (organic / cowdung/ sludge) in the ration of 5:1 (05 part of good earth & 01 part of manure) . Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% by stacked volume of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment add Thimet 10G granules @100gms / sq mts. Flooding the entire with water. Rough & fine dressing the flower bed area and removal of weeds & unwanted vegetation & its disposal with all lead and lifts , a) SEASONAL FLOWERING BED SIZEFORMAL STYLE - Lx1.0mts width, INFORMAL STYLE - Any style as desired , b) Supply & plantation of seasonal flowers sapling @36 seedlings / sq mts (minimum three times in a year) , i) BUL BOUS / CUTTINGS - FLOWERING - Dahalia Plants @16 plants / Sqm) Winter , c) Maintenance of flower beds regularly upto 1 year as per standard specifications. Replacement of casualty immediately , MOUND , Preparation of mounds of various size and shape by available excavated / supplied earth in a layers not exceeding 20cm in depth, breaking clods, watering of each layer, dressing etc with all lead & lifts complete as per direction of Officer in charge. Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth and 8% stacked volume of manure , BRICK EDGING , Edging with bricks (Class I) laid in PCC (1:2:4) length wise, including required excavation, refilling, consolidating withhand packing and spreading surplus earth neatly within all lead and lifts , Brick Paving : Supply and Paving of wire cut bricks on sand bed , Terracotta Pot : Terracotta Pots of height 4 & width 1m made with 8mm rod chicken mesh with cement mortar complete , PVC Pipe Line : Supply & laying of 63mm dia PVC pipeline of ISI including excavation of outlet back filling of trenches of 0.60m depth fixing with all accessories and providing outlet wherever required backfilling of trenches etc complete , Supply & erection of 2 Hp pump with all accessories including panelboard etc , Supply, erection, testing and commissioning of 1.5sqmm 3 core copper cable , GOOD EARTH / AGRICULTURE SOIL , a) Supply and stacking of good earth / agriculture soil from approved source / field ; of approved quality / pH & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. Cost of good earthto be paid separately, after reduction of 20% of stacked volume of good earth , b) Cattle manure : Supply of cattle manure , Note:- Where Ever Written for Sand Should be Read as Manufacture Sand
Contract Date: Feb 25, 2025 Contract Value : 47.47 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
38.
Banking and Finance #5971529 AOC
Bids Are Invited For Boqauto Extension If Any Seller Submits Price In Last 15 Minutes, The Rawill Be Auto Extended By 15 Minutes ( A Maximum Of101 Times ) Average Turn Over Of Last 3 Years 8 Lakh ( S ) Total Quantity : 1-- 1 Examination Table Rectangular Frame Four Strong Legs With Connecting Rods And Pvc Shoes. All Mild Steel Components Should Be Thoroughly In-House Pretreated Chemically To Remove Rust, Grease, Oil, Etc. By Dip Tank Processes, Including Separate Degrasing, Pickling, Phosphating Each Followed By Water Rinsing Passivating And Hot Air Drying To Give Phosphate Coating. Mattress Of Suitable Size With Good Quality Rexine Cover. 183Cm Lx76Cm Bx7Cm W. ISI/ISO certification 2 Step for Examination Table Examination Table Step ISI/ISO certification 3 Dressing/ Procedure Table Table for Dressing/ Procedure items SS Tubular Frame.SS Bowl & Bucket.SS Shelves with Railing. ISI/ISO certification 4 Instrument trolly (Medium) Build: Stainless SteelDimensions: 680 mm (L) X 450 mm (W) X 900 mm (H)Load Capacity: 50-100 kgISI/ISO certificationCastors Diameter: 100mm 5 Patient sitting stool 1.Stainless steel 2. Height: 18 - 27 Inch 3. ISI/ISO certification 6 IV stand 1. Stainless steel 2. With wheels at bootom 3. ISI/ISO certification 7 X ray view box 12 v LED illuminated single panel Sheet: Acrylic Sheet ISI/ISO certification 8 Examination lamp/light Light Source Type IncandescentShade Material PlasticMaterial PlasticBrand RKDENTWattage 100 WattsBase Material Plastic ISI/ISO certification ISI/ISO certification 9 Weighing machine 1. digital weighing machine 2. With Tempered Glass 280 x 280 mmCapacity 3. 2.3-180 Kg 4. ISI/ISO certification 10 IR thermometer 1. IR Thermometer 2. AAA Battery Powered 3. ISI/ISO certification 11 Foetal Doppler Light Weight, Handset, Portable • High Resolution Ldc Display • Audible & Visual Alarm • Ultrasound Probe – Solid, Anti-Shock, Durable • Built-In-Loudspeaker • Support 2Mhz, 2.5Mhz, 3Mhz, 4Mhz, 8 Mhz Water Proof Probes • Monitor 12 Seeks Above Unborn Baby’S Blood Wall Pulsate. • Ultrasound Probe: Solid And Durable, Anti-Shock, Anti-Falling Down • Ultrasound Frequency: 2/2.5/3 Mhz • Power: Ac 220V 50Hz, Built In 9.6V Rechargeable Batteries., • Power Source: Aa (9.6V Rechargeable) Batteries, Ac/Dc Adapter • Temperature (Working): +5°C~+40°C • Humidity (Working):≤80% ISI/ISO certification 12 Digital baby weighing machine 1. Digital Baby Weighing Machine 2. Battery: Rechargeable 3. Capacity: 30 kg 4. ISI/ISO certification 13 Infant Weighing scale 1. Beam type 2. Weighing Range: 0‐20 Kg 3. ISI/ISO certification 4. Digital 5. Rechargeable. 14 Nebulization Machine 1. Usable to both adults and child2. MMD approximately 5 micrometer3. Nebulizer rate : 0.4 milliliter per minute (without cap)Contains: Compressor, nebulizer kit, air tubes, 5 pieces replacement filters, mouth piece, adult mask, child mask, instruction manual and carrying bag and 1 year manufacturers warranty 4. ISI/ISO certification 15 Glucometer Accucheck active 16 Nebulisation machine 1. Usable to both adults and child2. MMD approximately 5 micrometer3. Nebulizer rate : 0.4 milliliter per minute (without cap)Contains: Compressor, nebulizer kit, air tubes, 5 pieces replacement filters, mouth piece, adult mask, child mask, instruction manual and carrying bag and 1 year manufacturers warranty 4. ISI/ISO certification 17 Spot light for delivery 1. Powerful LED light source.2. Mobile caster base with easy-glide wheels.3. 30-foot cord extends to enclosed wall-mounted transformer.4. Weighted base for added stability.5. Vented lamp shade with special reflector minimized heat output.6. Adjustable joined arm and swivel-joint lamp head allow for easyvertical and horizontal positioning with quick-adjust handle.7. 38.5” articulating arm (approx.)8. 4803” pole height (approx.) 18 Electric boiler Electric Instrument Sterilizer & Boiler - made of high quality Stainless Steel used for Sterilization /Disinfection of surgical instruments. It is fitted with thermostat & tray lifting arrangement.Size: 18 x 8 x 8inch Inches 19 Radiant warmer Essential features1. System should have integrated control panel, bassinet and warming unit2. System should have dimmable LED examination light3. Control panel should have single bright LCD display for warmer, & timer.4. All the parts that could come in potential contact with the baby shouldbe made of bio-compatible materials.5. Physical dimensions of the whole unit should not be more than 135 cm(L) x 75 cm (W) x 190 - 240 cm (variable height).6. System should have Integrated RS232 output for data or networkconnection.Warming unit1. Radiant warmer should be microprocessor based servo controlledwarmer.2. Mechanism of controlling heat should follow an algorithm to minimizeovershooting of temperature.3. Radiant heating elements should be made either of ceramic/ quartz/calrod.4. Size of heating element and reflectors should be made in such a designfor even heat distribution to every corner of the bassinet.5. Heating element should not be directly exposed (±grid) to protect theuser from accidental contact during operation.6. Heater head should swivel to either side (90 degrees) for easier accessand for enabling vertical x-ray exposure.7. Warming unit should allow to access the bassinet for surgery withoutdisturbing heating mechanism.8. It should have a separate warning light at the end.Control panelIt should have built-in self test when switched on which following features:9. Manual mode is to set temperature regardless of core temperature.Heater output should be adjustable from 0 to 100% in increments of 5%.10. Servo mode will automatically adjust heater output according totemperature difference between skin temperature and settemperature.11. Warm up time should be less than 10 minutes. 12. European CE or US FDA Certificate. 13. Five year warranty. 14. Company should be ISO certified. 15. 3yr warranty with 3 year comprehensive maintainenace cover (CMC). 20 Delivery instrument trolly Dimensions W x H x D (cm)47.5 x 155.5 x 104.8MaterialTrolly should have three shelves made of completely SS with safety edges on 3 sides. The cart has two sets of 3 drawers with lock facility and 6 colored bins for storing medicines and syringes. 21 Spica cast table 1. Table Top height: 10″2. Table Top length: 19.5″3. Table Top width: 19.54. Weight bearing capacity: 90kg5.. ISI/ISO certification 5. It may be customized as per reuirement. 22 Electric plaster cutter 1. Handle material: Rubber/plastic 2. ISI/ISO certification 3. WARRANTY : 1 Year warranty 4. Motor wire: made of copper 4. Cord Length: equal or more than 3 meter 5. Safety lock feature 5. Ball Bearing mounted, well ventilated motor for use on A.C. or D.C. supplies, with switch, housed in a shockproof, insulated casing, Having input wattage of 90W 6. Heavy duty, Light weight with aspirator 7. With Blades to Cut normal and Synthetic Plasters. 8. Spare Blades -10 23 Infant Weighing scale digital 1. It should be a digital electronic scale2. Should have capacity weighing range of 0 - 20 kg with an accuracy of ±5 gm3. Weighing unit: Standard display in grams4. Pan size: 630 x 300 mm ±25mm5. Pan material: Fibre resistant plastic (pupe coated)6. Display: Bright LED or LCD display for easy viewing7. Should have functions TARE, Auto-HOLD and Automatic switch-off8. Insulation should be Protection9. Should be light weight and has a handle for easy transportation10. The scales are only cleaned with normal disinfectants11. Should have operated by battery or power supply 12. ISO/ European CE certification13. Warranty : Minimum 1 year 24 Electronic weighing machine 1. Capacity : 150 Kg2. Graduation: 100gm3. Tare, auto hold, body mass indexfunctions4. Automatic zero setting5. Operable on mains or rechargeablebatteries6. ISO/ISI/European CE certification 7. Warranty: minimum one yr 25 Nebulizer - machine, mask, tubing 1. Usable to both adults and child2. MMD approximately 5 micrometer3. Nebulizer rate : 0.4 milliliter per minute (without cap)Contains: Compressor, nebulizer kit, air tubes, 5 pieces replacement filters, mouth piece, adult mask, child mask, instruction manual and carrying bag and 1 year manufacturers warranty 4. ISI/ISO certification 26 nitrous oxide Jumbo cylinder 1. Capacity 46.7Ltr D-type 2. Material: Mild Steel Grade: Medical 4. ISO/ISI/EUROPEAN CE certification 27 View box 1. LED illuminated2. single panel Sheet 3.Acrylic Sheet4. Power: 12 V, 50-60Hz 2. ISI/ISO certification
Contract Date: Ref. Documents Contract Value : 16.50 Lakh
Government Departments No of Bidders 5
Contract Date: Ref. Documents Contract Value : 1.88 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 1
Contract Date: Ref. Documents Contract Value : 4.55 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
West Bengal View Result →
42.
Banking and Finance #4613547 AOC
Strong Room Door Class B Saharanpur Strong Room Door Class B Saharanpur , Item , Technical Specification Of Trtl Vault ( Strong Room ) Door ( Class-B ) With Exhaust Fan, Ventilator, V-Cage The Vault ( Strong Room ) Door ( Main Door ) Dimension And Specification Shall Be Strictly Adhering To Is 11188 ( Part-1 ) :2014, The Door Shall Have Bis Label Of Class B Having Torch & Tool Resisting Capacity For Minimum 30 Minutes And Fire Resisting Capacity For Minimum 30 Minutes., The Bidder / Oem Must Possess Valid Bis License To Manufacture And Supply The Aforementioned Trtldoor ( Class B ) , All The Surfaces Of The Door Before Painting Shall Be Thoroughly Degreased And Cleaned Of Rust And Scales Preferably By 12 Tank Pickling Process And Treated Chemically To Prevent From Rusting., The Door Shall Be Painted Inside And Outside With An Anti-Corrosive Primer Followed By Two Undercoats Of Paints And Finally Painted With Quick Drying Paint, Resulting Into Minimum 300 Hrs Of Salt Spray Resistance. ( Attach Certificate / Declaration ) , The Main Door ( Class B ) Shall Consist Of Outer And Inner Mild Steel Plates Conforming To Is 2062:1992 For Plates Up To 20 Mm Thick Strongly Rimmed And Continuously Welded To Form A Single Structure And Tightly Enclosing A Solid Slab Of High Speed Drill Resisting And Oxy Acetylene Torch Resisting Material That Is At Least 50 Mm Thick, Door Frame : The Door Frame And Vestibule Shall Be Welded To One Piece Construction With A Minimum Thickness Of 10 Mm And Shall Grip The Concrete Wall., Rebate : The Rebate Of The Door Frame Shall Be Formed By Mild Steel Sections. The Vertical Rebates Shall Be Riveted Or Welded With The Side Members Of The Door Frame And Shall Conform To Dimensions As Specified By Is 11188., Clenching Mechanism : A Continuous Resilientpacking Shall Be Incorporated In The Frame And A Conpression Mechanism For Clenching The Door Tight Shall Be Provided So As To Protect Against Admission Of Flood Water Or Liquid Explosives. In Locked Position The Door After Clenching Shall Not Have Any Play In The Direction In Which The Door Opens., Thickness Of Door Over Locks : Should Be Of Minimum 90Mm Thickness., The Door Shall Have An Automatic Relocking Device For Each Key Lock Fitted In The Door Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosives Or By Other Means. , Primary Lock Of The Door Shall Have Additional Relocking Device Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosive Or Any Other Means., The Lock Shall Be Dual Control Type And Have At Least 8 Active Levers Of Brass Of Minimum 1.2 Mm Thickness. There Should Not Be Any Dummy ( False ) Levers., The Bidder / Oem Must Be The Original Equipment Manufacturer Of The Locks Used In The Aforementioned Safe. ( Oem Must Give A Written Undertaking On Letterhead And Must Also Give An Noc The Bank For Plant Visit If Needed ) , Lock Case : Should Be Minimum 2 Step Case Construction Covering Entire Jamb Area., The Lock Shall Be Fixed With At Least Four Bolts Of 8 Mm Diameter Such That Any Pressure Applied On The Bolts Either Directly Or Through Handle Of The Door, Is Not Transmitted To The Fixing Screw Of The Lock / Locks. All Working Parts Of The Lock Shall Have Corrosion Resistant Properties Capable Of Withstanding Exposure For 72 H In Standard Salt Spray Test With 5 Percent Salt Solution. , Bolt Work : There Shall Be 6 Locking Bolts Each On The Vertical Edges Of The Door ( Front Edge & Rear Edge ) ., Hinges : Strap Hinges To Be Suitably Bolted To The Door Shultter. The Hinge And Pivot Should Be Such That There Is No Appreciable Friction Or Play For The Movement Of The Door. The Pivots Shall Have Arrangements For Lubrication And A Height Adjustment Bold Is To Be Provided To Adjust Height Of Door Shutter. , Grill Gate ( Inside ) : Ventilating Grill Gate Shall Be Made Of Mild Steel Angles, Plates Or Channels With Mild Steel Rods Welded In A Rigid Frame. The Grill Gate Shall Be Hinged In Strong Room Door Frame Such That It Opens Inside. An Unpickable Dual Control Locking Device Capable Of Being Operated From Both The Sides Of The Door Shall Be Fitted In The Grill Gate. , Emergency Door : The General Specifications Of Emergency Door Shall Remain As For The Main Door Except For Bolt Work. For Bolt Work, There Shall Be 3 Locking Bolts Each On The Vertical Edges Of The Emergency Door ( Front Edge & Rear Edge ) ., Limit Switch / Lighting Control: Vault Lighting Control Shall Be Fitted On The Main Door To Automatically Control The Electric Supply To The Vault.
Contract Date: Oct 05, 2021 Contract Value : 4.91 Lakh
Cooperative No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 4.95 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 12
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 9.44 Lakh
Boards / Undertakings / PSU No of Bidders 5
45.
Health and Family Welfare #2175812 AOC
Corrigendum - E Tender For Procurement Of Dental Items Used In Dentistry For Two Years From The Date Of Award Of Contract ( Aoc ) - 1 3Rd Generation- 2 6Th Generation- 3 Acryliser N 4 Adam’S Plier With Tungsten Carbide Tip N Nspecification: N Nfor Orthodontic Work. N 5 Adam’S Plier N 6 Adson Forceps, Toothed N 7 Adson’S Forceps Non Toothed N 8 Air Polisher N 9 Aluminum Slide Trays N Nspecification: N Nmade Of Aluminum Ntray Dimensions: 11.25 X 7.25 X 0.25 In.Holds 20 Each Of 25 X 75 X 1Mm Slides 10 Amalgam Carrier N Nspecification: N Nmade Of Stainless Steel 11 Amalgam Plugger N Nspecification: N Nmade Of Stainless Steel Double Ended 12 Amalgamator With Plunger N Nspecification: N N• Input Voltage 220-230V N• Provided With Touch Pad Selector N• Pre-Programmed Time Setting N• Quiet, High-Speed Mix Capsules N• Built-In Automatic Timer N• Capsule Holder Accepts All Types Of Amalgam Capsule N• With Plunger N• Customized Trituration Times 13 Anatomical Articulator N Nspecification: N N1. Rust Free Construction. N2.Fixed Condylar Guidance With Spring Mounted Elements That Are Attached To Upper Member N3. Incisal Pin. 4. Mid Incisal Pin N5. Orientation Rod, 6. Incisal Guide Table N7. Support Upper & Lower Plaster Cast 14 Anterior Jacquette N Nspecification: N Nset Of Three. ( 1 Pc Straight & Two Pc Curved ) Nmade Of High Quality Stainless Steel. 15 Apexo Elevators N Nspecification: N Nset Of Two Set Of Right & Left Made Of Stainless Steel. 16 Austin’S Retractors N Nspecification: N Nl-Shaped With One Rounded End And One Forked End Nmade Of Stainless Steel 17 Babcock’S Forcep N Nspecification: N Nfinger Ring, Ratcheted, Non-Perforating Forceps Used To Grasp Delicate Tissue Nmade Of Stainless Steel 18 Band Contouring Pliers N Nspecification: N Nfor Orthodontic Work. Made Of Hard Tempered Steel 19 Band Cutting Scissors N Nspecification: N Nfor Orthodontic Work. Nmade Of Hard Tempered Steel 20 Band Pinching Pliers Set N Nspecification: N Nset Of 1 Piece Each Ofleft & Right Nfor Orthodontic Work. Made Of Hard Tempered Steel 21 Band Pusher N Nspecification: N Nfor Orthodontic Work. Made Of Hard Tempered Steel 22 Band Remover Anterior & Posterior N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 23 Band Seater N Nspecification: N Nfor Orthodontic Work. Made Of Hard Tempered Steel 24 Binocular Compound Microscope N Nspecification: N Nsharp Image Display With Excellent Optical Function, Small Space Occupancy With Integral Stand Design, Low Environment Requirement With Anti-Mould Technology. Ncomfortable Operation With Ergonomic Design Principle Nviewing Head: Compensation Free Binocular Head Inclined At 30O Interpupilary Distance 55-75Mm Neyepiece: Wide Field Eyepiece Wf10x / 18Mm With Eye Guard, Achromatic Objective 4X, 10X, 40X, 100X, Nfocussing Range: Co-Axial Coarse And Fine Adjustment Range 13Mm Fine Division 0.002Mm With Tension Control. Nnose Piece: Quadruple Nosepiece, Nstage: Double Layer Mechanical Stage 140 X 140 Mm / 75 X 50 Mm N.A1.25 Abbe Condenser With Iris Diaphragm And Filter. Nfocussing: Coaxial Coarse & Fine Adjustment System Range 24Mm, Fine Division 2Mm Nillumination: Led Light With Brightness Adjustable. Iso 13485 Or Ec Certificate / Directive 93 / 42 / Eec ) 25 Block Holders N Nspecification: N Nto Be Used To Hold Paraffin Blocks And Not Made Of Plastic 26 Blow Torch N Nspecification: N Nfor Casting Procedure: Nmade Of Non Corrosive High Fusing Alloy Nprovided With Air Flow Regulator, Two Separate Inlet Line For Lpg Gas & Oxygen 27 Boley Gauge N Nspecification: N Nmade Of Stainless Steel For Measuring Tooth Dimensions & Others. 28 Bone Expansion And Splitting Kit N Nspecification: N Nthe Kit Consists Of Nosteotomes-Set Of 5-6 Of Various Diameters Nspreaders N Burs Surgical For Bone Removal N Saw Disc N Thumb Driver & Rachet Nautoclavable Cassette 1 Piece 29 Bone File Howard Type N Nspecification: N Nstraight Or Curved Working Ends Nto Smooth Bone For Better Contour Of Alveolar Ridge Crosscut Or Straight Cutting Ridges Double Ended Nmade Of Stainless Steel 30 Bone File Miller Type N Nspecification: N Ndouble Ended Made Of Martensitic Stainless Steel 31 Bone Grafting Syringe N Nspecification: N Nfor “Tamp And Pack” Method For Placement Of Graft Material Into Oral Cavity. 32 Bone Rongeur End Cutting N Nspecification: N Nscissor-Type Handle, Cutting Edges On Top Edge Of Beaks Made Of Martensitic Stainless Steel 33 Bone Rongeur Side Cutting N Nspecification: N N Scissor-Type Handle, Cutting Edges On Side And Top Of Beaks 34 Bone Shear N Nspecification: N Nlength 6-8Inches.Made Of Stainless Steel 35 Boon’S Gauge N Nspecification: N Nhigh Quality Stainless Steel Framework With Minimum Nmarking Till 6Mm 36 Bracket Debonding Plier Anterior N Nspecification: N N For Band Removal Orthodontic Work. Tungsten Carbide Tipped 37 Bracket Debonding Plier Posterior N Nspecification: N Nfor Band Removal In Orthodontic Work. Tungsten Carbide Tipped 38 Bracket Holding Tweezer N Nspecification: N Nfor Orthodontic Work. Made Of Hard Tempered Steel 39 Brass Flask Size No 6 N Nspecification: N Nfor Acrylic Denture Fabrication By Compression Moulding, With Detachable Upper, Body & Lower Member With Keyways. Made Of Brass 40 Buck Knife N Nspecification: N Nsize- ¾ & 5 / 6 For Use In Periodontal Surgery 41 Bur Chuck For Dental Lathe N Nspecification: N Nof Different Shapes For Attaching Abrasive Stone Point, Stone Wheel & Other Attachments 42 Buser Bone Chisel N Nspecification: N N6mm Pointed Tip Made Of Martensitic Stainless Steel Alloy 43 Camel Hair Painting Brush Size-04 44 Canine Contouring Plier N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 45 Casting Ring Extra Large N Nspecification: N Ncasting Ring Extra Large Nmade Of Steel Nfor Use With Centrifugal Casting Machine Nlength 4 & Diameter X 4.75Or More 46 Casting Ring Large N Nspecification: N Nmade Of Steel Nfor Use With Centrifugal Casting Machine . Nlength3 & Diameter X 3.75 47 Casting Ring Medium N Nspecification: N Nmade Of Steel For Use With Centrifugal Casting Machine . Nlength2 & Diameter X 2.75 48 Casting Ring Small N Nspecification: N Nmade Of Steel For Use With Centrifugal Casting Machine . Nlength1.25 & Diameter X 1.75 49 Casting Tong N Nspecification: N Nmade Of Stainless Steel Or High Fusing Alloy For Holding Casting Ring 50 Castrovejo Needle Holder N Nspecification: N Ncastroviejo Microsurgical Needle Holder Is A Double Spring Instrument Used For Holding Small, Delicate Needles In Various Microsurgical Procedures. It Also Features A Locking Mechanism.Made Of Stainless Steel, Autoclavable 51 Castroviejo Scissor N Nspecification: N Ncastroviejo Scissor Has Curved Blades. Nultra-Sharp Blades Microscopic Serrations Provide A Smooth Cut. Nspring-Loaded Knurled Handles Provide The Control You Need To Make Perfectly Smooth Cuts In Delicate Materials. Nstainless Steel, Autoclavable 52 Cement Mixing Spatula N Nspecification: N Nmade Of Stainless Steel Double Ended 53 Ceramic Sculpturing & Finishing Kit N Nspecification: N Ncomprising Of High Quality Sable Hair / Synthetic Filament Brush Size One Zero, Two Zero And Four Zero And Other Sizes, Ceramic Curver, Mosquito Forcep, Tweezer, Ceramic Pallete For Mixing Ceramic Powder And Other Associated Carving & Finishing Instruments. 54 Chandler Chisel-With 5Mm Tip N Nspecification: N Nwide Single Bevelled Blade Chisel Nmade Of Martensitic Stainless Steel Alloy 55 Chanel Retractor N Nspecification: N Nlength 17.5 Cm, Made Of Stainless Steel 56 Chin Retractor Obwegeser Type N Nspecification: N Nlength 15.5 Cm, Made Of Stainless Steel 57 Chisel Curved N Nspecification: N Nchisel Curved 20Mm Nmade Of Martensitic Stainless Steel 58 Circular Saw N Nspecification: N Nfor Dental Model Cutting: With Self Illumination Nprovided With Motor Driven Circular Saw Blade And Cast Holding Platform, Electrically Operated Motor Driven With Push Button Type On Off Switches. 59 Clinical Micromotor-Brushless N Nspecification: N Nelectrically Operated With Handpiece Nhandpiece Autoclavable Upto 135 Degree Celcius, Handpiece Speed 1000-40000Rpm, Speed Maximum Output Power 1.2W, 3.4-3.5 Ncm Torque, With Option Of Clockwise & Anticlockwise Rotation. N Control Box And Foot Control Mechanism. 60 Colorado Needle And Accessories. N Nspecification: N Nelectrosurgical Needle Is Needle Electrode For Use In Monopolar Electrosurgical Handpiece Made Of Tungsten Carbide. Coagulation Tips & Cutting Tipsshould Work With Most Of The Diathermy Units Available In The Hospital , Operating Frequency Above 3 Mhz. Niso / Fda / Ce 13485 Or Ec Certificate ( Directive 93 / 42 / Eec ) 61 Composite Curing Unit System N Nspecification: N Nfor Indirect Composite Work Nchamber Provided With Sliding Tray, Provided With Multiple Halogen Or Led Lights Light Intensity Not Less Than 900 Mw / Cm2output Peak Wavelength Range 450 - 490 Nm ( Intensity Maximum At 460 Nm ) Ncapable Of Curing Indirect Composite Veneers / Inlays N. Curing Chamber Dimension : Nlength 10 Inches Nwidth 7 Inches Nheight 4 Inches Or More Nelectrically Operated 220-230 Volts Nportable With Timer 62 Cooley Bulldog Clamp N Nspecification: N Nstraight 8.6Cm Jaw 4.7Cm Made Of Stainless Steel 63 Coplin Staining Jar Vertical Type 64 Crane Kaplan Pocket Marker N Nspecification: N Npair Of Two Instruments –Right & Left 65 Crane Kaplan Scaler N Nspecification: N N Double-Ended, Round Handled Periodontal Instrument For The Removal Of Heavy Supragingival Calculus. It Is A Sickle Type Scaler, With A Strong, Rigid, Sharply Angled Blade 66 Crown Gauge ( Iwanson Caliper ) N Nspecification: N Nfor Measuring Thickness Of Wax Pattern, Metal Casting. Nboth Sided Scale 0-10Mm 67 Crucible For Small Casting N Nspecification: N Nmade Of Fused Silica / Ceramic Material, Capable Of Withstanding High Temperature For Use With Centrifugal Casting Machine 68 Curing Pressure Pot N Nspecification: N N5 Liter Or More Capacity Npressure Pot Temperature Is Preset To Approximately 120°Fand Manually Adjusts To A Maximum 160°F. Nsolid Clad Bottom Provides Even Heat Distribution. Nincludes An Easy-To-Read, Built-In Pressure Gauge And Quick-Release Air Valve. Nthe Pot Has A Safety Device To Prevent Overheating, And A Secure Double-Locking Lid. Neasy-To-Clean Stainless Steel Interior. Npot Holder To Keep Pot Firmly Nin Place. Nwith Lid Gasket 69 Cushing Nerve Hook N Nspecification: N Nused For The Retraction Of Nerves Or Delicate Tissue During Neurosurgery. Nthe Instrument Has A Ball Tip To Avoid Tearing. This #1 Hook Is Angled 90 Degrees With A 4Mm Ball Tip And Overall Length Of 7-1 / 2 Inches 70 Dandy Type Nerve Hook N Nspecification: N N Length 16-20Cm Ntip 4-5Mm, Deep Working Tip Blunt Ended Made Of Stainless Steel 71 Dappen Dish Made Of Glass 72 De La Rosa Wire Contouring Plier N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 73 Deans Scissors: N Nspecification: N Nscissors With 1 Serrated Angular Blade Used For Trimming Tissue Or Cutting Sutures. 74 Debackey’S Forceps N Nspecification: N N Length 26 Cm, Tip Width 1.5 Mm Made Of Stainless Steel 75 Debackey’S Vascular Forcep 6” N Nspecification: N Nmade Of Stainless Steel, Autoclavable 76 Debakey Bulldog Clamp 8.5Cm N Nspecification: N Nwith Serr.Jaws, Straight Made Of Stainless Steel 77 Dental Dewaxing Unit N Nspecification: N Nwith Digital Control For Water Temperature Regulation. Construction: Stainless Steel Ntank Sizes ( 300 X 200 X 350 Mm ) Approximately Nwater Filling: Manual Heater: 2000 Watts. With Drain Valve 78 Dental Excavator Discoid Type N Nspecification: N Nmade Of Stainless Steel Double Ended Niso 13397-4:1997 79 Dental Lathe Motor N Nspecification: N Nac, Hp-1, Universal, Rpm-2800, Equipped With Double B.B, Single Speed, Rating Continuous With 3 Chucks ( Buffer, Stone & Bur Chuck ) , Three Imported B.B. Flexible Metal Cable Arm And Its Attachment. 80 Dental Muffle Furnace N Nspecification: N N1150c Degree Celsius, Working Temperature 900 Degree Celsius, With Er & Digital Display Nmuffle Size 175X175x225mm. 4.0 K.W. Capacity 81 Dental Phantom Head Unit N Nspecification: N Nmanikin Head Fixed With A Table, With Mounted Upper & Lower Jaw Containing Screw Mounted Teeth Having 90° Swiveling Function Of Head Unit, Provided With Control Box For Micromotor, Foot Control & Micromotor With Contra Angle Handpiece, Should Have Mounted Light Unit With Illumination Power Not Less Than 7000 Lux. 82 Dental Plaster Dispenser N Nspecification: N Nbody Made Of Stainless 304 Grade, Fitted With Digital Electronic Timer, Capacity 5 Kg Or More. Will Dispense Premeasured Dose Of Plaster At Touch Of A Button. 83 Dental Steam Cleaner N Nspecification: N Npower 1500W Or More, 220V, Frequency 50 / 60Hz. Working Pressure: 4-5 Bar. Capacity 5-10Litre. With Thermostat Controller.Device With Both Steam Gun & Button / Lever Controlled Steaming Attachment With Steam Regulator. Stainless Steel Non Rusting Inner Tank Body. 84 Dental Surveyor Tool Kit N Nspecification: N Ntools- Nanalyzing Rod Multiple Undercut Gauges N Carbon Marker Sheath N Wax Trimmer 85 Dental Surveyor Ney’S Type N Nspecification: N Ndental Surveyor Ney’S Type Nhorizontal Platform N• Adjustable Spindle For The Vertical Indicator N• Survey Table That Can Be Locked At Any Angle. Nwith Tools- Analyzing Rod Undercut Gauges N Carbon Marker Sheath N Wax Trimmer Etc Nprovision For Holding Micromotor Handpiece Nstandard Packaging / Physical Verification Of Sample May Be Made 86 Dental Tweezer N Nspecification: N Nwith Horizontal Serrations At Tip, Diamond Knurling On The Outside For Good Grip, Stainless Steel Alloy 87 Dental Vacuum Former Machine N Nspecification: N Nelectrically Operated, With Inbuilt Vacuum Motor Suction Unit, Heating Element With On Off Switches & Adjustable Clamping Plate. Nspecifications: Nvoltage : 230V / 50-60Hz Npower : 600W-230V Nheater : 400W-230V Ndimension : L 23-25 Cm, W 17-20 Cm 88 Dg 16 Endodontic Explorer 89 Diamond Glass Marker N Nspecification: N Nmounted In Aluminum Pencil 5 Inches ( 12.7Cm ) 90 Die Cutting Machine N Nspecification: N Nelectrically Operated With Diamond Disc. Nwith Adjustable Model Holder Nself Illuminated Chamber 91 Dingmans Retractor N Nspecification: N Nwith Three Blades Made Of Stainless Steel 92 Distal End Bender N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel ) 93 Distal End Cutter N Nspecification: N Ntungsten Carbide Tipped Ncutter For All Types Of Wire Up To A Maximum Of .021” X .025” ( .53 Mm X .64 Mm ) 94 Distal End Cutter N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 95 Dontrix Gauge N Nspecification: N Nspring Balance Type, Minimum Measurement Till 500 Ngms To Precisely Calibrate Orthodontic Force There Are Two Units Of Measurement Ounce And Gram. Measuring Range: 0-450G / 0-16 Oz. To Measure Tension And Compression Force 96 Double Wax Heater Pot N Nspecification: N Nwith Thermostat Controlled Temperature Regulator Electrically Operated 97 Dry Model Trimmer N Nspecification: N N With Attached Suction Unit 98 Duplicating Flask N Nspecification: N N A. Programmable Brushless Agitator Motor Ntemperature Controls For Precision Warm Up And Cool Down Phases Nintelligent Heating Strategy And Provision For Effective Disposal Of Gel And Prevention Of Nozzle Blockage Nmaintainance Of Consistent Gel Quality Nvoltage: 200230V, 50 / 60Hz, Nb. Pressure Compaction Unit For Duplicating Silicone Materials Nautomatic Mixing And Metering Unit For Two Component Silicone Material Nduplicating Flask: N ( A ) Individual Aluminium Duplicating Flask With Aluminium Top And Rubber Base And 2 Base Formers ( 2 Sizes ) N ( B ) Duplicating Flask With Stabilizing Insert And Three Replaceable Palatal Formers Of Different Sizes 99 Electrically Operated Wax Carver N Nspecification: N Nelectrically Operated Electrical Wax Curver With Thermostat Controller. With Two Detachable Carving Tools 100 Electro Polisher N Nspecification: N Nautomatic Digital Electro Polisher, Auto / Manual Modes, Nwith Trimmers, Electrolyte Flow Regulation N38 Mm Disc For Psa Paper & Cloths Nsupply 230 V. Ac Ncurrent – 2.5 Amp., Voltage – 80V, Supply – 230 V.A.C.Polishing Probes – Unique Pen Type System With Recirculation Of Electrolyte, Pump 25 Watts Reservoir ( 0.5 Ltr ) 101 Endo Activator N Nspecification: N Nsystem Kit That Includes Handpiece / Driver Nbox Of Small, Medium & Large Activator Tips. Nbox Of 100 Protective Barriers. Safe & Vigorous Energetising Intracanal Irrigant, Capable Of Debriding & Disinfecting Root Canal System 102 Endodontic Microsurgical Equipment N Nspecification: N Ncomprising Of Na. Ultrasonic Piezoelectric Scaler With Inbuilt Irrigation , Led & Water Tank Nb. Ultrasonic Endodontic Retro-Surgical Tips ( For Anterior Teeth Upper & Lower And Posterior Teeth Of Upper And Lower Arch ) Nc. Ultrasonic Passive Irrigation, Nd. Set Of Assorted Ultrasonic Tip For Instrument Retrieval And Chasing Calcified Canal 103 Endomotor With Torque Control Nhand Piece. N Nspecification: N Ncontinuous & / Or Reciprocating Motions For Root Canal Shaping, Hand Piece With Integrated On- Off Switch, Auto Reverse Mode, Speed 250-1200 Rpm. N Torque Range 0.6-4 Ncm, N Multiple Adjustable Programs Nstandard Packaging / Physical Verification Of Sample May Be Made 104 Endovac Irrigation System N Nspecification: N N Multiple Port Adapters, Hand Piece Set, Extra Evacuation System, Cannulas, Delivery Tips & Syringes. 105 Excavator Oval Type 106 Excavator Spoon Type N Nspecification: N Nexcavator Double Ended Spoon Type 107 Extraoral Gothic Arch Tracer N Nspecification: N Njaw Movement Recording And Centric Relation Npositioning, One Stylus And One Tracing Plate Nattachments To The Jaw Movement Recording Bases Noutside The Mouth Nstandard Packaging / Physical Verification Of Sample May Be Made 108 Farabeufs Periosteal Elevator N Nspecification: N Nof Different Sizes- Length 6-8Inch, Width 8-12Mm, Made Of Stainless Steel. 109 Fergusons Mouthgag N Nspecification: N Nmade Of Stainless Steel N 110 Fiber Optic Light N Nspecification: N Nfiber Optic Based Lighting Unit Consisting Of Fiber Optic Cable, Led Based Portable Light With Controller Unit. With Rechargeable Battery Niso 13485 Or Ec Certificate ( Directive 93 / 42 / Eec ) 111 Flask Clamp For Brass Flask N Nspecification: N Nmade Of Steel With Clamp Compatible With Brass Flask Of Size No-6 112 Frahm Amalgam Curver 113 Furcation Curettes- Quetin N Nspecification: N Nbuccal-Lingual 0.9Mm-1Pc Quetin Buccal-Limgual 1.3Mm-1Pc Nquetin Mesial-Distal 0.9Mm-1 Pc Quetin Mesial-Distal 1.3Mm-1Pc Nconform To Iso 13485:2003 / En Iso 13485:2012 114 Gardner Chisel-With 3Mm Tip N Nspecification: N Nsingle Bevel Chisel Nmade Of Martensitic Stainless Steel Alloy 115 Gates Glidden Drill Set N Nspecification: N Nstainless Steel, Drill Compatible With Latch Type Handpiece For Use In Bulk Removal Of The Tooth Structure Nunit Pack Containing Six Different Sizes Each Drill Having 28-32 Mm Length. 116 Gillie’S Skin Hook- Doubleprong N Nspecification: N Nmade Of Stainless Steel N 117 Gillie’S Skin Hook-Single Prong N Nspecification: N Nmade Of Stainless Steel N 118 Glass Bead Sterilizer N Nspecification: N Nelectrically Temperature Regulated To Heat Contained Glass Beads With On Off Switch. Nsmall Rectangular Base For Keeping At Chairside Nprovided With Lid. N It Should Reach Operating Temperature Of Approximately 240 C To 270 C In 15-20 Minutes Time. Nsterilization Is On Contact With Glass Beads Nunit Can Be Left In The “On” Position All Day And Is Safe For Use In Laminar Flow Cabinets. 119 Glass Slab- 8Mm Thick N Nspecification: N Ntransparent Rectangular Glass Slab Thickness 8Mm, Length 6” X 4” Inch 120 Glass Slab Big N Nspecification: N Ntransparent Square Glass Slab Thickness 4Mm, Each Side Of 6 Inch 121 Glass Slab Small N Nspecification: N Ntransparent Square Glass Slab Thickness 4Mm, Each Side Of 3.5 Inch 122 Goldmanfox Periodontal Probe N Nspecification: N Ndouble Ended Probe, Markings At 1, 2, 3, 5, 7, 8, 9& 10Mm.High Quality Stainless Steel With Satin Finish, Antimagnetic Rust Resistant, Acid Resistant 123 Gracey Curette Set N Nspecification: N Nof 9 Size ½, ¾, 5 / 6, 7 / 8, 9 / 10, 11 / 12, 13 / 14, 15 / 16, 17 / 18.Made Of Hard Tempered Steel Ndouble Ended Nhandle-10.2-10.8Cm Nshank-3.1-3.6Cm Nlength-6.8-7.4Mm Noffset Blade Beveled At 60 -70 Degree To The Shank N1.Triple Tempered Steel N2.Satin Steel Handle N3.Corrosion Resistant N4.Rust Resistant N5.Stain Resistant N6.Can Be Sharpened By Traditional Sharpening Stones Nconform To Iso 13485:2003 / En Iso 13485:2012 Iso 13485 Or Ec Certificate ( Directive 93 / 42 / Eec ) Ce & Fda Aprroved 124 Guarded Nasal Chisel Set Of Right &Left N Nspecification: N Nsize : 4, 5, 6, 8Mm - Right & Left In Pair Made Of Stainless Steel 125 Half Round Plier N Nspecification: N Nfor Orthodontic Work. Made Of Hard Tempered Steel 126 Hand Scaler Set Of 5 Piece N Nspecification: N Nset Containing 1 Piece Each Of: Sickle, Push, Universal, Broad Right & Left . 127 Hard Wire Cutter N Nspecification: N Nhard Wire Cutter Made Of Tungsten Carbide Tipped 128 Heavy Duty Lathe With Suction Unit N Nspecification: N Nelectrically Operatedheavy Duty Motor Unit Having Power Not Less Than – 0.5Hp Nhigh Speed R.P.M.-3000 Rpm Narrangement To Attach Bur Holding Chuck – Electroplated Spindle On One Side For Polishing Buff Wheel, On The Other Arm Is A Grinding Stone Wheel Of Diameter 2.5 Inch Or More. Provided With Nbuilt In High Power Dust Suction Unit For Clean, Unpolluted, Dust Free Work Environment, Attached With Dust Collection Bag – Easily Removable Tray For Debris Collection. Ntable Mountable Heavy Base Plate For Vibration Free Operation Nbuilt – In Lighting For High Visibility 129 Heavy Wire Cutter N Nspecification: N Nwire Cutter Tungsten Carbide Tipped N 130 Hinge Articulator N Nspecification: N Nrust Free Construction Npermit Opening & Closing In Hinge Like Motion. Support Upper & Lower Cast. N Upper Member Adjustable With Locking Nut. 131 Hook Crimping Plier N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 132 Hot Plate With Wooden Handle 133 Howarth’S Periosteal Elevator N Nspecification: N Ndouble Ended: One End Flat, Broad Sharp Edge, Other End Rugine Ended Made Of Stainless Steel 134 Howe’S Pliers- Anterior N Nspecification: N Nwith Serrations, Useful For Placement And Removal Of Archwires, Pins And Other Auxiliares Nmade Of Stainless Steel 135 Howe’S Pliers- Posterior N Nspecification: N Npliers With Serrations, Useful For Placement And Removal Of Archwires, Pins And Other Auxiliares 136 Humby’S Knife Holder N Nspecification: N Nmade Of Stainless Steel N 137 Hydraulic Press N Nspecification: N Nthe Closed Circuit Hydraulic Press Should Work With A Pressure Up To 7000 Kg Of Thrust. N It Can Contain Up To Three Flasks At A Time. Nthe Structural Elements In Chromium Plated Steel. N Provided With Dial. 138 Hydro-Solder N Nspecification: N Nmains Voltage: 1 X 230 V, Mains Frequency: 50 X 60 Hz, Mains Fuse: 1 X 10. A Nmax.Gas Production: 6 Liter Nmax. Nozzle Size: 0.07Mm N Dimensions W X H X D X ( Mm ) : 330 X 230 X 310 Mm Nweight: 22 Kg Ncapacity: 110Lt, With Accessories 139 Implant Microsurveyor N Nspecification: N Nwith Compass Surveying System, Portable Hand Held Surveyor 140 Implant Retractor N Nspecification: N Nmade Of Stainless Steel. Autoclavable 141 Incubator N Nspecification: N Nrobust Construction Nflawless Finish Nlong Functional Life Ninner Chamber Size 14 X 14 X 14’’ With Two Shelves Nwith Thermostat Control & Digital Display Iso / Fda / Ce Or Ec Certificate 142 Inlay Wax Curver Double Ended 143 Instrument Sharpening Kit With Arkansas Stone N Nspecification: N N Flat Arkansas Stone With Conical Shape Nplastic Test Stick ( 5 ) Nstone Oil Nmagnifying Lens& Other Accessories 144 Intra Oral Camera With Video Monitor N Nspecification: N Na ) Camera: Neasy To Use, Narrow Head, Comfortable For Patient Intra Oral Camera With Provision Of Variable Lens Adjustment That Can Be Attached To Dental Chair Unit Nvideo Compatible So That Images Can Be Displayed On A Computer Workstation / Lcd Monitor Nstill Image Resolution: 1024 ( H ) X 768 ( V ) Or More Nvideo Resolution: 640 ( H ) X 480 ( V ) Or More Nfocus Range: 1 Mm - 25 Mm Nlens Surrounded By Led Lamp Ninput: 220V 50-60Hz Noutput: 5V, 2A 145 Intraoral Camera With Fluorescent Technology N Nspecification: N Nintra Oral Camera With Caries Detection And Periogingival Inflammation Detection Facility Based On Flurescent Technology 146 Intraoral Sand Blaster N ( Microetcher ) N Nspecification: N Nlong Tubing With Compatible Adapter For The Airotor Handpiece Point Nof The Dental Chair, Fully Autoclavable, 50 Microns Naluminium Oxide Particle Size, 360 Degree Adjustable Nozzle. 147 Intraoralgothic Arch Tracer N Nspecification: N Njaw Movement Recording And Centric Relation Npositioning, One Stylus And One Tracing Plate Nattachments To The Jaw Movement Recording Bases Ninside The Mouth N 148 Kilner’S Cheek Retractor N Nspecification: N Nmade Of Stainless Steel N 149 Kirkland Gingivectomy Knife N Nspecification: N Nfor Use In Periodontal Surgery N 150 Kocher’S Forceps N14cm Hemostatic Forcep. N Nspecification: N N It Is Specifically Designed To Catch The Bleeder That Are Deep Within Tissue Hence It Is Ideally Used On Tough Structures Made Of Stainless Steel 151 Laboratory Micromotor With Brushless Motor N Nspecification: N Ncompact And Portable Size, Continuous Variable Speed Control , R.P.M-1000 -40000, On / Off Foot Switchone- Touch Change Of The Driving Direction For Efficient Operation With Brushless Motor With Handpiece 152 Laboratory Micromotor With Carbon Brush Motor N Nspecification: N Ncompact And Portable Size, Continuous Variable Speed Control , R.P.M-1000 -40000, On / Off Foot Switchone- Touch Change Of The Driving Direction For Efficient Operation With Carbon Brush Motor With Handpiece 153 Langenback’S Retractor N Nspecification: N Nmade Of Stainless Steel N 154 Laser Guided Pin Drilling System With Pins N Nspecification: N Nelectrically Operated 110V / 240V, Laser Guided Pinsetter, Pin Drilling For Easy Die Pin Attachment. Nlaser Light Technology With Carbide Bur Drill With High Speed Motor. Nto Accurately Drill Parallel Holes Into The Underside Of The Model Die Pins Of Various Sizes ( 1000 Pieces Total ) Made With Non Corrosive Alloys For Use With Pindex System Of Die Pins. 155 Lead Apron N Nspecification: N Nadult Size, 0.5 Mm Thick Lead Covered With Cotton On Nboth Sides, Overstraps, Buckles & Hand Gloves ( Size 6 Nto 7.5 ) With 0.5 Mm Thickness Lead 156 Lecron Wax N Nspecification: N Ncurver Made Of Steel N 157 Leuckhart Pieces N Nspecification: N Ntwo L Shaped Metallic Stands For Preparing Paraffin Wax Block 158 Light Cure Unit N Nspecification: N N Led Based. Light Modes- Fast, Ramped & Pulsed Ndisplay For Mode & Timer Nselection Nchordless With Rechargeable Lithium Battery Nlight Intensity Not Less Than 1200 Mw / Cm2output Peak Wavelength Range 450 - 490 Nm ( Intensity Maximum At 460 Nm ) Nwith Inbuilt Timer, On Off Switch 159 Lingual Arch Plier N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 160 Loop Forming Plier N Nspecification: N Nfor Orthodontic Work. Nmade Of Hard Tempered Steel 161 Loop Forming Plier N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 162 Lower Molar Extraction Forcep English Pattern N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc / Box Type Of Hinge Joint Set Of One Piece Right & One Piece Lower Molar Forcep 163 Lower Premolar Extraction Forcep English Pattern N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc / Box Type Of Hinge Joint 164 Lower Roots Forcep N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip 165 Lower Universal Forcep N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc / Box Type Of Hinge Joint Set Of One Piece Right & One Piece Lower Molar Forcep 166 Magnification Loupes 3.5X N Nspecification: N Nergonomically Designed Binocular Loupe That Can Be Worn Over Spectacle Frame Capable Of 3.5X Magnification At 420Mm With 3Watt Led Rechargeable Light 167 Magnification Loupes 4.5X N Nspecification: N Nergonomically Designed Binocular Loupe That Can Be Worn Over Spectacle Frame Capable Of N4.5X Magnification At 420Mm With 3Watt Led Rechargeable Light N 168 Magnifying Work Lamp N Nspecification: N Nwith Flexible & Adjustable Stand And Base. Inbuilt Led Based Optical Illumination System. Nglass Lens Diameter 7 Inches Or More, Magnification Power Upto 4 X 169 Manual Crown Remover N Nspecification: N N With Adjustable Spring With Crown Remover Tip ¬ 2 Single Crown Remover Contrangled Tip ¬ 3 Open¬End Adjustment Wrench 170 Manual Press N Nspecification: N Nwith Base And Cross Bar Made With High Strength Steel. Nthe Structural Elements Made With Chromium Plated Steel. Ncapable Of Pressing Upto 1 To 3 Flasks At A Time. Nbase Should Have Holes For Attachment To Bench 171 Marquis Colour Coded Probe N Nspecification: N Nfor Periodontal Surgery Made Of Stainless Steel Colour Coded At 3-6 & 9-12 Mm 172 Mathieu Plier N Nspecification: N Nstraight & Curved For Orthodontic Work Nused For Ligature Typing And Placing Of Elastics 173 Mbt Gauge N Nspecification: N Nfor .022” Slot Nfor Orthodontic Work. Made Of Stainless Steel 174 Metal Impression Tray Non Perforated N Nspecification: N Nmade Of Non Corrosive Alloy Nfor Edentulous Patient Set Of Upper & Lower, Size 0, 1, 2, 3, 4. N ( Price Being Same To Be Supplied As Per Requirement Of User ) 175 Metal Impression Tray Perforated N Nspecification: N Nfor Dentulous Patient Nmade Of Non Corrosive Alloy Nset Of Upper & Lower, Size 0, 1, 2, 3, 4. N ( Price Being Same To Be Supplied As Per Requirement Of User ) 176 Metal Suction Tip N Nspecification: N Na ) 3Mm Diameter -10 Pc Nb ) 5Mm Diameter-10 Pc Nmade Of Stainless Steel 177 Micro Oscillating Saw N Nspecification: N Ncapable Of Easily Cutting Channels And Bone Blocks Nmaximum 12, 000 Oscillations Per Minute. Compact Design For Easy Access . Ntwo Shaft Lengths & 4 Blade Sizes For Optimum Access. Nincludes External Irrigation Port For Effective Bone Cooling Nuniversal E Type Coupling That Fits Implant Motor Unit 178 Microhead Air Rotor Handpiece N Nspecification: N Nsuitable For Use In Child Patient, Head Size 8.5 X 19.4 Mm, Provided With Water Spray, Body Made With Ceramics Autoclavable, Rotational Speed 3, 00, 000 To 450, 00, 00 Rpm, Provided With A Bur Changer & Wrench. Nphysical Verification Required 179 Micropipettes N Nspecification: N Nfeature Built-In Tip Ejectors And Autoclavable Tip Cones. Should Work On A Click-Stop Digital System, Are Easy To Calibrate And Maintain, And Easy To Disassemble For Autoclaving. Manufactured As Per Iso 9001:2008. Each Pipette Should Be Individually Calibrated According To Iso 8655 Standards.Calibration Certificate Must Be Provided With Each Pipette. Accuracy And Precision Values Should Be Those Laid Down In The Iso 8655 Standards.Built-In, Streamlined Tip Ejector Facilitates Easy Tip Ejection And Access To Narrow Necked Bottles And Tubes. Variable Volume Pipette: 50-200 Μl. Increments [ Μl ] : 1 9 Volume [ Μl ] : 50 To 200. Accuracy ( ± ) %: 0.6 To 1 11 Precision ( ± ) %: 2 To 0.3 12 It Should Be Ce Mark 180 Microvascular Instrument Kit N Nspecification: N Nkit Comprises Of- N1.Micro Scissors N2.Micro Needle Holder N3.Jwellers Forceps N4.Vessel Dilators N5.Liga Clips ( No.100.No.200 ) N6.Ligaclip Applicators N7.Vessel Clamp ( 2A, 2V, 3A, 3V ) N8. Vessel Clamp Applicator N9. Hand Held Colour Doppler Unit N10.Pneumatic Tourniquet Nspecification To Be Quoted By The Bidder / Manufacturer Nmicro Scissors- Ni ) Adventitia Scissors- Flat Handle , 8Mm Wide, Straight-Length Of 15Cms, Blades 19Mm – 5 Pcs Nii ) Dissecting Scissors – Flat Handle, 8Mm Wide , Curved, Length Of 15Cms, Blades 19Mm – 5 Pcs Niii ) Adventitia Scissors- Round Handle, 8Mm Diameter Of Tip, Straight, Length 15Cms, Blades 12Mm – 5 Pcs Niv ) Dissecting Scissors – Round Handle, 8Mm Diameter Of Tip, Curved, Length 15 Cms, Blades 12Mm – 5 Pcs Nmicro Needle Holder: Ni ) Flat Handle , 8Mm Wide, Curved, 14 Cms Length – 6 Pcs Nii ) Round Handle, 8Mm, Curved, 15 Cms Length – 6 Pcs Njewellers Forceps Ni ) Flat Handle , 9Mm Wide, Straight, 13.5 Cms Length – 6 Pcs Nii ) Flat Handle , 9Mm Wide, Angulated 45 Degrees, 13.5 Cms Length – 6 Pcs Niii ) Round Handle , 8Mm Wide, Straight, Plateau, 15 Cms Length – 6 Pcs Nvessel Dilators: Ni ) Flat Handle , 9Mm Wide, Angulated 10 Degrees, Nlength 11Cms – 6Pcs Nliga Clips – Made Of Stainless Steel, Autoclavable. Nno.100 – 150 Sets ( Each Set Containing 6 Liga Clips ) Nno.200 - 150 Sets ( Each Set Containing 6 Liga Clips ) Nno.400 – 100 Sets ( Each Set Containing 6 Liga Clips ) Nligaclip Applicator: Ngrooves On Inside Jaw Surfaces Of Applier Which Helps In Increasing Of Jaw Clip Security. Nangled Jaws To Improve Visibility Beyond Structures Nmechanical Stop. Nmade Of Stainless Steel And Autoclavable. 181 Mini Pin & Ligature Wire Cutter N Nspecification: N Ntungsten Carbide Tipped Ncuts Soft Wire Pins And Ligature Wire Up To .012” ( .30 Mm ) 182 Miscellaneous Hi N Nspecification: N N139 Plier For Orthodontic Work. Made Of Stainless Steel 183 Miscellaneous-Hi 184 Model Trimmer With Carborundum Disc N Nspecification: N Nmotor Rpm 2800 Heavy Duty, Equipped With Two Ball Bearing Single Speed, Rating Continuous With Buffer And 10 Carborundum Disc , With Heavy Base That Can Be Clamped And Installed On Underlying Table, With Water Inlet And Out Flow Water System. 185 Model Trimmer With Diamond Disc N Nspecification: N N1 / 2Hp, Rpm-2800, Heavy Duty Equipped With Two Ball Bearings, Single Speed, Rating Continuous With Buffer And One 10 Diamond Disc Rough Or Fine Without Suction.1 Piece Spare Diamond Disc To Be Provided 186 Model Trimmer With Double Disc N Nspecification: N None Diamond & One Carborundum Disc N Rpm 2800 Double Motors Horsepower-1 / 2 Or More Each, Heavy Duty, Equipped With Two Ball Bearings Each Motor, Single Speed, Rating Continuous With Fixed One10 Diamond Disc Fine, One Carborundum Coarse Cutting Wheel, Base Inlet, With Outflow Water System. 187 Molts Elevator N Nspecification: N Nlength 7”Double Ended With One Round, Blunted End And One Pointed End Made Of Stainless Steel 188 Mouth Prop N Nspecification: N Nautoclavable Made Of Stainless Steel With Rubber Pads For Intra Oral Use Over Occlusal Surfaces During Surgery. The Rubber Pads Are Of 4 Sizes Attached By A Stainless Steel Chain. 189 Naber’S Probe N Nspecification: N Nfor Use In Periodontal Surgery Double Ended Furcation Probe Nconform To Iso 13485:2003 / En Iso 13485:2012 190 Omega Loop Forming Plier N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 191 Orban Gingivectomy Knife N Nspecification: N Nfor Use In Periodontal Surgery N 192 Oschenbein Chisel Curved N Nspecification: N Nsize No. 1 And No. 2 Ochsenbein Chisels Periodontal Chisels. They Havethree Cutting Edges, A Flat Edge On The Tip And A Curvededge On Each Side Of The Tip. 193 Oschenbein Chisel Straight N Nspecification: N N17.5 Cm X 4 Mm Nsize No. 1 And No. 2 Ochsenbein Chisels Periodontal Chisels. They Havethree Cutting Edges, A Flat Edge On The Tip And A Curvededge On Each Side Of The Tip. 194 Osteotome 20Mm N Nspecification: N Nmade Of Stainless Steel N 195 Paeso Rimmer Drill Set N Nspecification: N Nstainless Steel, Drill Compatible With Latch Type Handpiece For Use In Bulk Removal Of The Tooth Structure Nunit Pack Containing Six Different Sizes Each Drill Having 28-32 Mm Length. 196 Palatal Trimmer N Nspecification: N Nprovided With1 Fast Cutting Trimmer, Electrically Operated , Rpm-2600 Or More Nbody Made With 304 Grade Stainless Steel, Or Non Rusting Alloy. Dull Finished Work Surface, Dust Collection With Adapter Hose, Provided With1 Fast Cutting Trimmer 197 Paquette Blade Handle 198 Paraffin Wax Bath ( Thermostatically Controlled ) N Nspecification: N Nconstruction – Double Walled Effectively Insulated.Wax Tank Of 20 Gauge Ss Sheet. Fitted With Laminated Wooden Rim And Anodized Alumininium Cover Mounted On 5 Cm Diameter. Nheater- Two 1 Kw Each Special Wax Heater. Nheat Control- Thermostat To Control Temperature Fron 30 Degree C To 110 Degree C Nfinish- Externally Finished In Oven Baked Naccessories-Power Plug, 1 Brush For Wax Application And Aluminium Sheet Mesh For Heater. 199 Pediatric Extraction Lower Incisors & Canine Forcep N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc Type Of Hinge Joint, 4.5 Inches Of Length 200 Pediatric Extraction Lower Molar Forcep N Nspecification: N Nfor Children Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc Type Of Hinge Joint, N 4.5 Inches Of Length 201 Pediatric Extraction Lower Premolar Forcep N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc Type Of Hinge Joint, 4.5 Inches Of Length 202 Pediatric Extraction Universal Forcep N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc Type Of Hinge Joint, 4.5 Inches Of Length 203 Pediatric Extraction Upper Incisor & Canine Forcep N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc Type Of Hinge Joint, 4.5 Inches Of Length 204 Pediatric Extraction Upper Molar Forcep Left N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc Type Of Hinge Joint, 4.5 Inches Of Length 205 Pediatric Extraction Upper Molar Forcep Right & Left N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc Type Of Hinge Joint, 4.5 Inches Of Length 206 Pediatric Lower Roots Forcep N Nspecification: N Nmade Of Hard Stainless Steel With -Knurnled Handle Grip, Disc Type Of Hinge Joint, 4.5 Inches Of Length 207 Pediatric Upper Roots Forcep N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc Type Of Hinge Joint, 4.5 Inches Of Length 208 Piezo Surgical Kit N Nspecification: N N Device With Intermittent Operation, 60 Sec On Then 30 Sec Off With Irrigation, & 30 Sec On- 120 Sec Off Without Irrigation, Power Supply 240V, 50 / 60 Hz, Maximum Power Absorbed 120Va. Surgical Tip Capable Of Modulating From 10 To 30 Or More. 29Khz Or More. Power Adjustable From 2.8 To 16W. Tip Vibration In Range Of 60-200Μm.Motor With Tips & Other Accessories N ( European Ce / Fda ( Usa ) Approved ) 209 Pikling Kit N Nspecification: N Nelectrically Heated And Thermostatically Controlled Pickling Unit For Acid Based Pickling Agents With Low Power Consumption For Pickling Of Precious Metals. Swivel Sieve And Housing Made Of Shock-Proof And Acid-Resistant Polypropylene Material 210 Pin & Ligature Wire Cutter N Nspecification: N Ntungsten Carbide Tipped Ncuts Soft Wire Pins And Ligature Wire Up To .015” ( .38 Mm ) 211 Plaster Knife N Nspecification: N Nwith Working Length Not Less Than 2 .5Inches 212 Plaster Spatula N Nspecification: N Nround Ended Steel Spatula Having Width Of 1.25 Inch & Length 5-6 Inches, With Plastic Or Wooden Handle 213 Plastic Filling Instrument Nward Type 214 Pneumatic Crown Remover N Nspecification: N Npneumatic, Autoclavable Tips, Basic Kit Includes Easy Pneumatic Crown And Bridge Remover Bridge Remover Tip ¬ 1 Single Crown Remover Tip ¬ 2 Single Crown Remover Contrangled Tip ¬ 3 Open ¬Ended Adjustment Wrench Rubber Gasket Flexi¬Wire Set 215 Pneumatic Deflasking Unit N Nspecification: N N Operates On Air Pressure. Nwith Handheld Chisel- Provided With Detachable Tips N Provided With Variable Powercontrol With Air Inlet And Tubing Length Not Less Than 1.5 Meter. Nworking Pressure 1-6 Bar 216 Portable Transcutaneous Electrical Nerve Stimulation ( Tens ) N Nspecification: N Nunit For Pain Management With Replacement Electrodes. The Machine Should Have Burst, Continuous And Modulation Pulse Modes. Dual, Isolated Between Channels With A Pulse Intensity Of 0-80Ma Peak Into 500Ohm Load. Pulse Rate Of 2-120Hz Adjustable. Pulse Width 40-260 Microseconds, Adjustable. Maximum Voltage: 110V. Maximum Charge: 21Microcoulombs Per Pulse 217 Pressure Moulding Machine N Nspecification: N Nthe Unique Thermally Controlled Heater Reaches Working Temperature In Few Minutes. Npower: 230 V, 850 W Nworking Pressure: 0, 5 – 6, 0 Bar Nmeasurements ( W X H X L ) : 450 X 230 X 260 Mm 218 Pulp Tester Digital N Nspecification: N Npreset Stimulus Speed Mode, Battery-9V, Auto-Off After 3 Min, With Autoclavable Tips, One Touch Operation, With Digital Read Out Of Display 219 Punch Biopsy Forceps N Nspecification: N Nmade Of Stainless Steel N 220 Rib Raspatory Right & Left N Nspecification: N Nmade Of Stainless Steel N 221 Rib Shear ( Doyan ) N Nspecification: N Nmade Of Stainless Steel N 222 Ribbon Arch Plier N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 223 Rme Bender N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 224 Robinson Black Bristle Brush N Nspecification: N Nhaving Diameter Of Not More Than 2.5 Inch. 225 Root Canal Explorer 226 Rowe Zygomatic Elevator N Nspecification: N Nmade Of Stainless Steel N 227 Rubber Bowl N Nspecification: N Nsize-Large N13 Cm In Height Made With Flexible Synthetic Rubber Material 228 Rubber Dam Kit N Nspecification: N Nrubber Dam Clamp Forceps Nrubber Dam Punch Nrubber Dam Frame - Adult Nuniversal Rubber Dam Template Nfdi Rubber Dam Nprovided With Different Clamp Designs Such As Molar Clamps, Bicuspid Clamps Winged, Labial Clamps Winged Nit Contains: N-Plastic Dental Dam Frame 6 / 5 N-Wedjets Stabilizing Cord Pack ( S ) N-Hygenic Template 6 / 5 N-Punch N-Forcep N-Rubber Dam Sheets 6X6 ( 36 ) / Pedo 5X5 ( 52 ) N-Set Of 9 Clamps-Adult / Set Of 6-Pedo 229 Sand Blaster Unit N Nspecification: N Nself Illuminated Chamber. Unit With Ventilation Slits With Rubber Gloves, Pressure Regulator, Air Filter , Provided With Glass Pane. Flow Of Blasting Material From 1 To 6 Bar. With Wear Resistant Nozzle Tip Attached With Wear & Tear Resistant Hoses & Nozzles. With Filter. Micro & Macro Mode 230 Sanders Knife Nsize-1 / 2 231 Schluger Bone File For Use In Periodontal Surgery 232 Self Adjusting Endodontic File System ( Saf System ) N Nspecification: N Ndigitally Controlled Endodontic Micromotor With Peristaltic Pump. N Self Adjusting Root Canal Files, Rotary Motion With Speed And Torque Control, Nreciprocating Motion With Reverse / Forward Angular Movement 233 Self Retaining Retractor- Weit Laner Type N Nspecification: N N Made Of Stainless Steel N 234 Semi Adjustable Articulator With Accessories N Nspecification: N Nwide View Arcon Articulator With Spring¬ Bow, Ear¬Piece, Face Bow, Orbital Indicator, Bite Fork & Other Accessories Nstandard Packaging / Physical Verification Of Sample May Be Made 235 Separator Placement Pliers N Nspecification: N Nfor Orthodontic Work. Nmade Of Hard Tempered Steel 236 Sinus Lifting Instrument Kit N Nspecification: N Nfor Lateral & Crestal Approach N With S-Reamer / Lateral Reamers Ninitial Drill / Crestal Drills N Bone Inserter Nbone Spreader N Bone Carrier N Bone Condenser Ndepth Gauge N Chisels Of Different Width N Sinus Curettes- Of Various Designs N Bone Rongeur Forceps Nmallet Nirrigation Syringe & Tips N& Other Instruments Nautoclavable Cassette 1 Piece 237 Slide Storing Cabinet N Nspecification: N Ncabinet For 1050 Slides Consisting Of 6 Drawers Each For 175 Slides, Arranged In Single Rowframework Made Of 15Mm Plywood With Top And Sides Covered With Sunmica Laminated Sheet. 238 Slide Warming Table N Nspecification: N Ntop Surface Made Of Stainless Steel ( Ss-304 Grade ) Nthe Surface Temperature Is Controlled From Ambient To 70°C Nsupplied Complete With Pilot Lamp, Cord And Plug Nto Work On 220 / 230 Volts A.C. Supply 239 Spirit Lamp N Nspecification: N Nmade Of Stainless Steel Nof 100 Ml Capacity With Wick & Detachable Cap Stainless Steel Body 240 Spot Welder With Soldering Attachment N Nspecification: N N• Electrically Operated N• Voltage110 - 240 Volts N• Applications / Indication Spot Welding N• Power Settings2, 000 Amperes N• Heat Settings2 N• Electrode / Tip Type Hand Electrode N• Welding Positions Adjustable 241 Steel Mallet N Nspecification: N Nfor Use In Oral Surgical Work Made Of Stainless Steel Length 7.5”, Nhead Diameter 20-22Mm 242 Steel Slide Racks For Staining N Nspecification: N N The 5-Slide Gripper Can Accommodate 5 Microscope Slides In One Staining Procedure.It Fits Most Coplin And Round-Open Staining Jars Nit Should Be Made Of A Special Material Which Is Resistant To All Chemicals And Solvents Which Are Used In Staining Nit Withstands Drying Temperatures Up To 80°C 243 Step Plier N Nspecification: N Nfor Orthodontic Work. Made Of Hard Tempered Steel 244 Surgical Elevators- Coopland’S Pattern N Nspecification: N Nmade Of Hard Stainless Steel N 245 Surgical Elevators- Cryer’S Pattern N Nspecification: N Nmade Of Hard Stainless Steel Nlength 145Mm, Neck Diameter 3.6Mm, Working Tip Length 9Mm For Right & Left Nset Of 2 Units Cryer’S Right, Left 246 Surveyor Mounted Miling Machine N Nspecification: N Nuniversal Precision Milling Unit. Areas Of Application; Wax Milling And Scraping ; Milling, Fine Grinding, Drilling And Smoothing Of Metal With The Help Of The Modeling Spindle, It Can Be Used As A Surveying Instrument And For Mounting Auxiliary Parts. Magnetic Locking Device For Model Table. Drilling Depth Stop And Connection Facilities For Additional Handpiece For Finishing. Advantages: Universal Design For Measuring, Blocking And Routing ( Router Head Accept Spindles, Drawing Tools And Measuring Tools ) . Easily Movable Double Articulating Arm Free From Play. Routing Spindle With Quick Coupling. Controllable, Heatable Wax Knife Nrpm Can Be Infinitely Controlled From 3000 To 35000 Rpm. Left / Right Rotation. Route Head With Micrometer Screw For Exact Vertical Bores. Good Illumination Due To Integrated Led Light Iso 13485 Or Ce Certificate 247 Three Prong Plier N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 248 Tissue Biopsy Kit N Nspecification: N N1.Small And Short Scalpel Blades ( No. 15, 11, 12 Or Even 5 ) – N 2. Mosquito Forceps – 2 Pc Curved & 2 Pc Straight N3. Gauze Container Made Of Stainless Steel- Size Small 1Pc N 4. Alley’S Tissue Forcep 2Pc N5. Punch Biopsy Set-One Piece Of Three Different Diameters ( Circular Blade Size 3 Mm, 5Mm & 7 Mm ) In Each Kit N6. Mc Indoe’S Dissecting Scissor1pc N7. Bone Scoop- Small1pc N8. Bone Curette- Tip Diameter 3 Mm-1Pc N9. Sklar Tungsten Carbide Bozeman 10.Needle Holder 8 Tungsten Carbide Tipped- 1 Pc With Catch, N11. Wards Needle Holder- 1Pc N12. Toothed Dissecting Forcep-1Pc N13. Non Toothed Dissecting Forcep-1Pc 249 Tissue Capsules / Tissue Embedding Cassettes N Nspecification: N Nmade Of Acetyl Polymer;Cassettes Should Keep Specimen Safely Submerged In Liquid, Efficient Flow-Through Slots, Snap-Latch And Hinge-Lock Design Prevent Early Separation Of Base And Lid And Allows For One Hand Operation. Large Labeling Area On Two Sides Of Cassette. Anterior Writing Area Is At 35° Angle. Npore Size: 1Mm Square Pores Noutside Dimensions: 28.5 X 41 X 6.7Mm ( 1.12 X 1.61 X 0.26 ) Ninside Dimensions: 26 X 30 X 5Mm ( 1.02 X 1.18 X 0.2 ) 250 Tissue Floatation Water Bath N Nspecification: N N ( Thermostatically Controlled ) Inner Tank ( Single Piece ) Made Of Black Anodized Aluminum. Housing Made Of Powder Coated Aluminum. Front Panel Consist Of Temperature Regulator Knob, Mains Switch And Pilot Lamp. Inside Black And Outer Surface Finished In Powder Paint, With Wide Enough Rim For Drying The Wet Slides. Nbath Size ( Inner ) -225Mm*70Mm Ntemperature- Controlled By Capillary Tube Thermostat Ntemperature Range- N+5 Degree C To 70 Degree C 251 Torch, Alcohol, Dental N Nspecification: N Nwick Volume Capacity 90Ml Or More, With Adjustable Needle Point Flame, Body Metal Or Plastic 252 Torquing Pliers Male N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 253 Torquing Pliers Male N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 254 Tourniquet- Arm N Nspecification: N Nhaving Pressure Regulator, Tubing And Connectors With Not Less Than7 Cm Inflatable Cuff 255 Tourniquet- Leg N Nspecification: N Nhaving Pressure Regulator, Tubing And Connectors With Wide 14 Cm Inflatable Cuff 256 Towel Clips ( Clamps ) Nbackhause Type N Nspecification: N Nto Secure Surgical Drapes And To Secure Plastic And Rubber Tubing To Drapes Features: Sharp Prong Tips 31 / 2 Inchand 51 / 4 Inch Additional Use: Remove Metal Temporary Crowns Made Of Stainless Steel 257 Towel Cross Section Clip N Nspecification: N Nmade Of Stainless Steel Used To Fix Drapes To Tissue With Minimal Trauma During Surgical Operations 258 Tracing Table N Nspecification: N Nbox Portable With Opaque Screen Nlight Box With Led Nelectrically Operated With Ajustbale Illumination. Box Dimension 14” X 16” Or More 259 Transparency Scanner N Nspecification: N Ndual Lens System, Minimum 6, 400 Dpi Optical Nresolution, 4.0 Dmax For Smooth Gradation And Fine Nshadow Detection, Antireflective Noptical Coating And Nhigh Reflection Mirror, Digital Ice Technology, 8” X 10” Ntransparency Unit Built Into Lead 260 Trephine Bur Set N Nspecification: N N Of 3. Dia- 2, 3, 4Mm Nfor Harvesting Bone Cores For Use In Periodontal Surgery Iso 13485 Or Ec Certificate ( Directive 93 / 42 / Eec ) 261 Turret N Nspecification: N Nzero Torque ( Blue ) Nfor Orthodontic Work 262 Tweed Plier N Nspecification: N Nfor Orthodontic Work. Made Of Stainless Steel 263 Typhodont Articulator N Nspecification: N Narticulated Model With Soft Pink ( Not Transparent ) Acrylic Or Plastic Gingiva Material. Included:28 Anatomically Shaped Screwable Typhodont Ivorine Teeth 264 Ultrasonic Cleaner N Nspecification: N N 220V, 100 -200Watt & Above, 5 Liter Capacity, With Stainless Steel Body &Cover. 265 Ultrasonic Dental Scaler N Nspecification: N Nelectrically Operated 220 / 240V 50 / 60Hz Ac With Control Box, Multi Frequency Handpiece With Scaling Tips, Foot Control, Water Connector, Tube & Other Accessories. Capable Of Upto 20Khz Ultrasonic Vibrations / Second Or More Niso 18397:2016 / Iso / Fda / Ce 13485 Or Ec Certificate 266 Unc -15 Periodontal Probe Plastic N Nspecification: N N Probe With Markings At 1-2-3-4-5-6-7-8-9-10-11-12-13-14-15Colour Coded At 5, 10 & 15Mm, Thin Shanked Probe 267 Unc -15 Periodontal Probe: Titanium N Nspecification: N Nprobe With Markings At 1-2-3-4-5-6-7-8-9-10-11-12-13-14-15Colour Coded At 5, 10 & 15Mm, Thin Shanked Probe Nconform To Iso 13485:2003 / En Iso 13485:2012 Iso 13485 Or Ec Certificate ( Directive 93 / 42 / Eec ) 268 Universal Columbia Curette N Nspecification: N Ncommon Properties: N1.Triple Tempered Steel N2.Satin Steel Handle N3.Corrosion Resistant N4.Rust Resistant N5.Stain Resistant N6.Can Be Sharpened By Traditional Sharpening Stones N7.Properly Designed & Balanced Handles To Reduce Chances Of “Carpal Tunnel Syndrome” Na ) In Different Sizes Nhandle-10-11Cm Nshank-2.7-3.2Cm Nblade-Length-5.8-6.5Mm, Width-1.3-1.6Mm, 90 Degree Offset Angle Nsemicircular Cross Section With Convex Base Nb ) In Sizes Of Sc4r / 4L6 Nhandle-10-11Cmshank-2.9-3.4-Cm Nblade-Length-5.8-6.5Mm, Width-1.3-1.6Mm, N90 Degree Offset Angle Nsemicircular Cross Section With Convex Base. 269 University Of Michigan O Probe N Nspecification: N Nfor Use In Periodontal Surgery Nsingle Ended Probe With Markings At 3-6-8Mm 270 Upper Canine Extraction Forcep English Pattern N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc / Box Type Of Hinge Joint 271 Upper Incisor Extraction Forcep English Pattern N Nspecification: N Nforcep Made Of Hard Stainless Steel With Knurnled Handle Grip, Disc / Box Type Of Hinge Joint 272 Upper Molar Extraction Forcep English Pattern N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc / Box Type Of Hinge Joint Nset Of One Piece Right & One Piece Left Upper Molar Forcep 273 Upper Premolar Extraction Forcep English Pattern N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip, Disc / Box Type Of Hinge Joint 274 Upper Roots Forcep N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip 275 Upper Universal Forcep N Nspecification: N Nmade Of Hard Stainless Steel With Knurnled Handle Grip 276 Uv Steriliser N Nspecification: N Ndimensions Of Cabinet: 22 X 12 X 8” Nfront Door With Uv Protected Glass Window & Magnetic Door Seal Nprovided With Multiple Tray Racks Not Less Than Four Nelectrically Operated Nprovided With Uv Light Source 277 Vacuum Investment Unit N Nspecification: N Ncapable Of Mixing Unit Amount Of Investment Material Under Vacuum Through A Motor 278 Vacuum Mixing Machine N Nspecification: N N1. Vacuum Mixing Machine Nfor Mixing Investment Material N2. Electrically Operated Motor 1500 Watts Or More N3. Compact N4. Automatic Regulation Of The Vacuum N5. The Mixing Motor Remains Clean And Is Easily Serviced Due To A Supporting Filter And A Fine Filter In Conjunction With The Maintenance-Free Vacuum Pump N6. Direct Connection Between Mixing Bowl And Vacuum Pump – No Disturbing Exterior Hose N7. Mechanical Coupling Tolock The Mixing Bowl In Position N8. A Mixing Bowls ( 500 G ) Niso 13485 Or Ce Certificate N 279 Vibrator N Nspecification: N N• Electrically Operated - Size 4.5 X 8 X 6.5 Inches Or Moreplatform Shaperectangular, Type Heavy Duty N• Constructionenamel Painted Body With Rubber Plate Above Body, Speed: 3-Speed Vibration Controller N• Platform Shaperectangular 280 Warwick James Elevators N Nspecification: N Nmade Of Hard Stainless Steel Nset Of 3 Units Right, Left & Straight Tips 281 Wax Block Storing Cabinet N Nspecification: N Ncabinet Made Out Of Duro-Board, Externally Clad In Laminated Sheet. Dust-Proof Door Is Lockable. Provided With Smoothly Sliding Drawers With Sixteen Compartments Each Of Size 4X4x2 And Have Puller Knobs. Each Compartment Can Store Blocks In Two Rows. 282 Wax Burnout Furnace N Nspecification: N Nmaximum Temp 1200C Working Temp 1150C With Digital Display Cum Temperature Controller With Safety Alarm Nmuffle Size : 175X175x225mm N 4.0K.W 283 Wax Curver: Pkt Type N Nspecification: N Nset Of 5 Instruments N 284 Wax Knife N Nspecification: N Nmade Of Stainless Steel Nwith One End Bearing Knife Pointed & Other Thick, Flat With Curved End 285 Wax Spatula N Nspecification: N Nmade Of Stainless Steel Nwith One End Pointed & Other End Curved 286 Weingart Plier N Nspecification: N Ntungsten Carbide Tipped N 287 Westcott Curved Tenotomy Scissors N Nspecification: N N19mm / 21Mm Made Of Stainless Steel 288 Who Probe N Nspecification: N Na. Clinical Nb. Epidemiological N Na. Clinical – 0.5 Mm Ball At The Tip, Making At 3.5Mm, 8.5Mm, 11.5 Mm, Colour Coding 3.5-5.55 Mm Nweight – 5 Gm Nb. Epidemiological- Marking At 3.5 Mm & 5.5 Mm N0.5 Mm Ball At The Tip 289 Williams Probe N Nspecification: N Nfor Use In Periodontal Surgeryth Marking At 1, 2, 3, 5, 7, , 9 & 10Mm 290 Wire Cutter N Nspecification: N Nmade Of Hard Tempered Steel N 291 Wire Tucker N Nspecification: N Nfor Orthodontic Work. Tungsten Carbide Tipped 292 Wooden / Plastic Slide Boxes N Nspecification: N Nframework With Finger Joints Fabricated Out Of Teakwood With Sunmica Top And Plywood Bottom. Wooden Grooves For Standing 3”X1” Glass Slide In Vertical Position Individually. Inside Bottom Covered With Velvet And Inside Top With Printed Index. Provided With Brass Chromium Plated Hinges Clips And Card Frame. Finished In Natural Color Niro-Cellulose Lacquer. 293 Wooden Mallet N Nspecification: N Nhaving Wooden Head That Is10 Cm In Length, Round At One End Of Diameter 3 Cms While Tapered At Other End, Handle Length 28 Cms Nfor Prosthodontic Laboratory Use 294 Woodson Periosteal Elevator N Nspecification: N Ndouble Ended- One End Curved ( Curved Working End- Length: 10-14 Mm, Width: 5-6Mm ) Nflat Tapered End: Length – 14-16 Mm, Width At The Widest Point- 4-6 Mm
Contract Date: Mar 19, 2021 Contract Value : 1
Government Departments No of Bidders 4
West Bengal View Result →
46.
Shipping #1683882 AOC
Annual Maintenance Contract Of Industrial Buildings Upto 7M Height And Connected Civil Works; 1 Painting With Two Coat Coaltar Epoxy Paint, Over One Coat Coaltar Epoxy Primer, After Rubbing And Cleaning The Surface, Mechanical Buffing, Including Cost And Conveyance Of All Materials, Labour, Other Incidentals, Temporary Lifeline Installation Charge Etc. Complete. ( If Necessary Compressed Air And Its Equipments Will Be Issued Free Of Cost From Csl ) . 2 Painting With Coaltar Epoxy Paint, After Rubbing And Cleaning The Surface, Mechanical Buffing, Including Cost And Conveyance Of All Materials, Labour, Other Incidentals, Temporary Lifeline Installation Charge Etc. Complete. ( If Necessary Compressed Air And Its Equipments Will Be Issued Free Of Cost From Csl ) 3 One Coat Coaltar Epoxy Paint 4 Succeeding Coat 5 Painting With Two Coat Synthetic Enamel Paint Over One Coat Zinc Chromate Primer, Afterrubbing And Cleaning The Surface, Mechanical Buffing, Including Cost And Conveyance Of All Materials, Labour, Other Incidentals, Temporary Lifeline Installation Charge Etc. Complete. 6 Painting With Synthetic Enamel Paint, After Rubbing And Cleaning The Surface, Mechanical Buffing, Including Cost And Conveyance Of All Materials, Labour, Other Incidentals, Temporary Lifeline Installation Charge Etc. Complete. 7 One Coat Synthetic Enamel Paint 8 Succeeding Coat 9 Painting With Two Coat Aluminium Paint Over One Coat Zinc Chromate Primer, After Rubbing And Cleaning The Surface, Mechanical Buffing, Including Cost And Conveyance Of All Materials, Labour, Other Incidentals, Temporary Lifeline Installation Charge Etc. Complete. ( If Necessary Compressed Air If Available Will Be Issued Free Of Cost From Csl. ) 10 Painting With Aluminium Paint After Rubbing And Cleaning The Surface, Mechanical Buffing, Including Cost And Conveyance Of All Materials, Labour, Other Incidentals, Temporary Lifeline Installation Charge Etc. Complete. ( If Necessary Compressed Air And Its Equipments Will Be Issued Free Of Cost From Csl. ) 11 One Coat Aluminium Paint 12 Succeeding Coat 13 Painting With Two Coat Exterior Plastic Emulsion Paint Over One Coat Cement Primer, For All Works, After Rubbing And Cleaning The Surface Using Wire Brush, Sand Paper Etc., Including Cost And Conveyance Of All Materials, Labour, Other Incidentals, Curing Etc. Complete. 14 Painting With Exterior Plastic Emulsion Paintfor All Works, After Rubbing And Cleaning The Surface Using Wire Brush & Sand Paper Or Water Wash Etc. Including Cost And Conveyance Of All Materials, Labour, Other Incidentals, Curing Etc. Complete. 15 One Coat Exterior Emulsion Paint 16 Succeeding Coat 17 Writing Letters Or Figuresin Any Language Using Two Coats Synthetic Enamel Paint Of Approved Brand And Colour, Upto 3M Height, Including Cost, Conveyance, Other Incidentals Etc. Complete. Measurements Will Be Taken For Each Character. 18 Letter Size Upto 10Cm 19 Letter Size Between 10Cm And 20 Cm 20 Painting Guard Lines On The Floors, Upto 100Mm Wide Using Synthetic Enamel Paint Of Approved Colour Including Cost And Coveyance Of All Materials, Labour Charges Etc. Complete. 21 One Coat Painting 22 Two Coat Painting 23 Roofing Of Buildings Upto 7M Height With 0.56Mm Thk Aluminium / Fibre Corrugated Sheet Or Coloured Aluminium Trafford Sheet With Overlaps Of 150Mm Longitudinally And On Crest Along The Width, Using 6Mm Dia Self Tapping Screws Or 8Mm Dia G.I. Hooks With Nuts & Washers. Screws Shall Be Provided Longitudinally Along The Overlap At Sheet At Spacing 250Mm C / C. Screws Shall Be Provided At All Purlins At Every Alternate Crest Of Roofing Sheet. Hip Shall Have Screw At Every Crest Of Roofing Sheet. The Rate Including Cost And Conveyance Of All Materials, Labour, Charges Of Fixing And Removing Temporary Lifeline & Roof Ladder Up To 6M Length Etc. Complete ( New Structures Shall Be Provided With Self Tapping Screws Only And The Existing Structures Will Be Permitted With Gi Hooks Or Self Tapping Screws As Per The Existing Conditions ) . It Should Be Ensured That The Roofing Area Shall Be Leak Proof After The Completion Of The Work. 24 0.56Mm Thick Aluminium Corrugated Sheet 25 0.56Mm Thick Coloured Aluminium Trafford Sheet 26 1Mm Thick Fibre Corrugated Sheet 27 Cladding Of Buildings At Height Upto 7M, With 0.56Mm Thk Aluminium / Fibre Corrugated Sheet Or Coloured Aluminium Trafford Sheet With Overlaps Of 150Mmlongitudinally And On Crest Along The Width, Using 6Mm Dia. Self Tapping Screws. Screws Shall Be Provided Longitudinally Along The Overlap At Sheet At Spacing 250Mm C / C. Screws Shall Be Provided At All Purlins At Every Alternate Crest Of Roofing Sheet. Hip Shall Have Screw At Every Crest Of Roofing Sheet. The Rate Including Cost And Conveyance Of All Materials, Labour Etc. Complete. It Should Be Ensured That The Cladding Area Should Be Leak Proof After Completion Of Work. 28 0.56Mm Thick Aluminium Corrugated Sheet 29 0.56Mm Thick Coloured Aluminium Trafford Sheet 30 1Mm Thick Fibre Corrugated Sheet 31 Roofing / Cladding Of Buildings Upto 7M Height With G.I. / Aluminium / Fibre / A.C. Corrugated Sheets / Asbestos Free Cement Sheets / Aluminium Trafford Sheets With Overlaps Of 150Mmlongitudinally And On Crest Along The Width, Using 6Mm Dia Self Tapping Screws Or 8Mm Dia G.I. Hookswith Nuts & Washers.Screws Shall Be Provided Longitudinally Along The Overlap At Sheet At Spacing 250Mm C / C. Screws Shall Be Provided At All Purlins At Every Alternate Crest Of Roofing Sheet. Hip Shall Have Screw At Every Crest Of Roofing Sheet. The Rate Including Cost And Conveyance Of All Materials, Labour, Charges Of Fixing And Removing Temporary Lifeline & Roof Ladder Up To 6M Length Etc. ( New Structures Shall Be Provided With Self Tapping Screws Only And The Existing Structures Will Be Permitted With Gi Hooks Or Self Tapping Screws As Per The Existing Conditions ) . It Should Be Ensured That The Roofing / Cladding Area Should Be Leak Proof After Completion Of Work.Sheets Will Be Issued From Csl Free Of Cost. 32 Supplying And Fixing 0.56Mm Thick Aluminium Coloured Trafford Ridge / North Light Curve / Barge Board At Height Upto 7M. Using Self Tapping Screws, Including Cost And Conveyance Of All Materials, Labour, Charges Of Fixing And Removing Temporary Lifeline & Roof Ladder Up To 6M Length Etc. Complete. Width Of Ridge Shall Be Minimum 400Mm. It Should Be Ensured That The Aluminium Coloured Trafford Ridge / North Light Curve / Barge Board Area Should Be Leak Proof After Completion Of Work. 33 Providing Flashing With 0.5Mm Thick Aluminium Plain Sheet With 200Mm Overlap At Ends Including Cutting And Bending, Using 6Mm Dia Self Tapping Screwsof Make M / S.Corroshield / Hilti Including Cost And Conveyance Of All Materials, Labour, Charges Of Fixing And Removing Temporary Lifeline & Roof Ladder Etc. Complete. It Should Be Ensured That Theflashing / Barge Board / Ridge Area Should Be Leak Proof After Completion Of Work. 34 Dismantling A.C. / G.I. / Fibre / Aluminium Corrugated Sheets / Plain Sheets Or Aluminium Trafford Sheets Of Roofing / Cladding At Height Upto 7M Including Conveying And Stacking The Dismantled Materials In Csl Premises, Charges Of Fixing And Removing Temporary Lifeline & Roof Ladder Up To 6M Length Etc. 35 Refixing The Loose Displaced A.C. / G.I. / Aluminium Roofing Sheets Of All Sizes In Position Using 6Mm Dia Self Tapping Screws Of Make M / Scorroshield / Hilti Or 8Mm Dia G.I. Hooks With Nuts, Washersincluding Cost Of All Materials, Labour, Conveyance, Charges Of Fixing And Removing Temporary Lifeline & Roof Ladder Upto 6M Length, Incidentals Etc. 36 Replacing / Providing 8Mm Dia G.I. Bolt / J Bolt For A.C. / Aluminium / Fibre / Galvalume Roofing Sheets Or Cladding Sheets With Necessary Nuts, Washers, Roofing Compound Etc. At Height Upto 7M Including The Cost And Conveyance Of All Materials, Labour, Stacking The Dismantled Bolts In Csl Premises Etc. 37 Replacing / Providing 6Mm Dia Self Tapping, Self Drilling Screws With Epdm Ceiling, Washers For G.I. / Aluminium / Fibre / Galvalume Roofing / Cladding Sheets At Height Upto 7M, Including The Cost And Conveyance Of All Materials, Labour, Fill The Holes Of Old Screws With Roofing Compound Etc. Complete. Screws Are Fixed On Crest For Roofing Sheets And On Valley For Cladding Sheets. 38 Cutting Down, Dismantling, Lowering All Types Of Structural Steel Works, Downwater Pipes, Valley Gutters, Trusses, Beams Etc. By Gas Cutting Or Unbolting From Heights Upto 7M, Including The Cost Of All Materials, Labour, All Incidentals, Temporary Lifeline Installation Charge Etc. And Stacking The Materials In Csl Premises, Complete. Oxygen, Acetylene And Compressed Air For The Work Will Be Issued Free Of Cost From Csl, According To Availability. 39 Supply, Fabrication & Erection Of Structural Steel Work, Using Tees, Angles, Channels, Plates Etc. At Height Upto 7M, Fixed With Or Without Connecting Plate, Including Cutting, Bending, Welding / Bolting, Fabrication, Erecting In Position, Aligning The Erected Structure, Cost Of All Accessories, Hire For Tools And Plants And Applying A Priming Coat With Zinc Chromate Primer After Mechanical Buffing, Temporary Lifeline Installation Charge Etc. Complete. 40 Supply, Fabrication & Erection Of Structural Steel Work, Using Ms Pipes, Ms Square Or Rectangular Tubes ( Class B Medium ) , At Height Upto 7M, Fixed With Or Without Connecting Plate, Including Cutting, Bending, Welding, Fabrication, Erecting In Position, Aligning The Erected Structure, Closing The Ends Of The Pipes / Tubes And Doing Complete Welding, Cost Of All Accessories, Hire For Tools And Plants And Applying A Priming Coat With Zinchromate Primer After Mechanical Buffing, Temporary Lifeline Installation Charge Etc. Complete. Pipe Ends To Be Closed And Done In Full Weld. 41 Ms Pipe-Upto 65Mm Nb 42 Square Or Rectangular Tubes Upto 100Mm Size 43 Fabricating And Erecting All Types Of Steelwork Including Downwater Pipe, Cisterns, Gutters Using Joists, Channel, Pipes, Angles, Plates Etc, Upto 7M Height Including Cutting, Bending, Welding, Erecting In Position, Aligning The Erected Structure, Bolting Or Welding Wherever Necessary, Cost Of All Accessories, Hire For Tools And Plants, Temporary Lifeline Installation Charge Etc. But Excluding Cost Of Steel ( Welding Rod, Oxygen, Acetylene And Compressed Air Will Be Issued Free ) Provision Of Bolt Holes After To Be Made At No Extra Cost If Necessary And The Rate Is Inclusive Of Bolts And Nuts With Washers Of Approved Quality, Including Collecting, Transporting Steel Items Anywhere In Csl Free Of Cost. 44 Dismantling And Refixing The Rails Of Various Lengths And Sizes, After Removing The Rail Clip Fittings And Fish Plates, Cutting If Required, Cleaning The Dismantled Items, Transpsorting The Rails To The Csl Pressing Machine / Maintenance Shop, Getting Them Straightened And Transportiong Back To Site, Refixing To Correct Line & Level With Packings, Clip Fittings And Fish Plates, Chemicals, Shim Plates ( For Works Above Ground Level ) , Including Cost Of All Labours, Machinery, Transportation, Cutting, Welding Etc. Complete ( Railpads And Rail Clip Fittings, Bolt Etc. Will Be Issued By Csl, Free Of Cost ) . For Tightening Bolts, Electrical / Battery Operated Torque Wrench Shall Be Used. 45 Correcting The Line And Level Of Rails Of Various Sizes And Lengths After Removing The Rail Clip Fittings And Fish Plates, Cutting If Required, Cleaning The Dismantled Items, Refixing With Old Or New Clip Fittings And Fish Plates, Chemicals / Rail Pad Or Combination Of Both For Correction Of Rail At Ground Level Or Packing Materials / Shim Plates For Works Above Ground Level, Including All Labour, Machinery, Cutting, Welding Etc. Complete ( Chemicals, Rail Pads, Packing Materials, Rail Clip Fittings & Bolts Will Be Issued By Csl Free Of Cost ) . For Tightening Bolts, Electrical / Battery Operated Torque Wrench Shall Be Used. 46 Fixing Mechanical Anchor Bolts 16Mm Dia. 150 / 165 / 220Mm Long, After Drilling Suitable Holes To Required Depth In Concrete Floors, Crane Track Etc. Cleaning The Holes, Placing The Bolt To Correct Line And Level, Including Cost And Conveyance Of All Materials, Labour, Tools Etc. Complete, Bolt Will Be Supplied By Csl Free Of Cost. 47 Cutting And Removing Old Rusted Clip Bolts, Nuts And Washers Of Crane Rails At All Heights And Replacing With New Gi Bolts, Nuts And Washers, Including Cost And Conveyance Of All Materials, Labour, Tools Etc. Complete. For Tightening Bolts, Electrical / Battery Operated Torque Wrench Shall Be Used. 48 Tightening Nuts Of Various Size Bolts, Used For Connecting Rails, Auxillary Girder To Gantry Girder, Fixing Rail Clips To Gantry Girders, Connecting Gantry Girders To Columns Etc. Using Electrical / Battery Operated Torque Wrench Including Rectification Of Small Alignment Variations. ( In Case Where Complete Nuts Are Tightened In A Rail Length ) 49 Tightening Nuts Of Various Size Bolts, Used For Connecting Rails, Auxillary Girder To Gantry Girder, Fixing Rail Clips To Gantry Girders, Connecting Gantry Girders To Columns Etc. Complete. For Tightening Nuts, Electrical / Battery Operated Torque Wrench Shall Be Used. ( In Case Where Scattered Nuts Are Tightened In A Rail Length ) 50 Supplying And Applying Roofing Compound Around Roofing G.I. Bolts Or Self Tapping Screws, At Heights Upto 7M Including Cost And Conveyance Of All Materials, Labour, Charges Of Fixing And Removing Temporary Lifeline & Roof Ladder Up To 6M Length Etc. Complete. 51 Stopping Water Leakage Through The Cracks, Gaps, Leakages In Ac Sheet / G.I. Sheet / Valley Gutter / Downwater Pipes, At Height Upto 7M By Pasting Tarfelt Sheet / Bostik Flashband Tape / Sika Multiseal Tape After Cleaning The Surface, Making Dustproof And Making The Surface Moisture Free, Fixing Tape, Tying With Binding Wire In The Case Of Downwater Pipes Including Cost Of All Materials, Labour, Tools And Other Incidental Charges, Charges Of Fixing And Removing Temporary Lifeline & Roof Ladder Up To 6M Length Etc. Complete. 52 Upto 0.01 M2 53 Above 0.01 M2 54 Cleaning The Roof Top Ofshops Having Height Up To 7M, By Brushes And Brooms Including All Labour, Removing Off All Dirt, Leaves, Wild Growth Etc., Disposing The Debris Within Csl Premises, Temporary Lifeline Installation Charge Etc. Complete. 55 Cleaning The Valley Gutters / Eaves Gutter Without Causing Any Damage To The Gutter, Including Removing All Debris Within Csl Premises, Temporary Lifeline Installation Charge Etc.Complete 56 Cleaning Of Crane Rail Track And Clearing Of Debris Or Soil To Waste Bins And Depositing It To Csl Dumpyards. Rate Includes All Labour Charges, Tools Etc. 57 Cutting Of Branches Of Trees On Top Of Roof Without Causing Damage To Roofs At Height Upto 7M, Without Any Damage To The Existing Roof Or Structures And Lowering The Cut Branches To The Ground And Stacking The Material Within Csl Premises. 58 Between 10Cm & 15Cm Girth 59 Between 15 Cm & 25Cm Girth 60 Supplying And Fixing Pvc Downwater Pipes 4Kg / Cm2 To The Correct Line And Level Including Cost Of Specials For Fixing The Pipes By Means Of Necessary Brackets In Concrete / Steel Structurals, Fabricating And Fixing Clamps @ 1.5M C / C, Cost And Conveyance Of All Materials, Labour, All Necessary Fixtures, Couplers, Incidentals And Applying Zinc Chromate Primer & Synthetic Enamel Paint On The Brackets Etc. Complete, Excluding Cost Of Structurals. 61 110Mm Dia 62 160Mm Dia 63 200Mm Dia 64 315Mm Dia 65 Demolishing Pcc / Rcc Work Including Stacking The Available Material And Reinforcement Separately And Clearing Away The Debris Within Csl Premises Etc. Complete. 66 Demolishing Brick / Concrete Blocks / Rubble Work, Manually / Mechanically Including Disposal Of Debris Within Csl Premises Etc. Complete. 67 Earthwork Excavaton In All Type Of Soil And Depositing On Bank With A Lift Upto 1.5M Including Backfilling And The Disposal Of Surplus Soil Within Csl Premises Etc. Complete. 68 Providing And Laying Plain Cement Concrete 1:4:8 Using 40Mm Stone Aggregate, Is Nominal Size Hard Broken Metal, Including Cost And Conveyance Of All Materials, Cement, Formwork, Labour For Mixing, Laying, Consolidating Curing Etc. Complete. 69 Providing And Laying Pcc / Rcc Work 1:1 1 / 2: 3 Using 20Mm Stone Aggregate Including Cost And Conveyance Of All Materials, Cement, Formwork, Labour For Mixing, Laying, Consolidating, Curing Etc. Complete But Excluding Cost Of Reinforcement. 70 Providing And Laying Pcc / Rcc Work 1:2:4 Using 20Mm Stone Aggregate Including Cost And Conveyance Of All Materials, Cement, Formwork, Labour For Mixing, Laying, Consolidating, Curing Etc. Complete But Excluding Cost Of Reinforcement. 71 Supplying Tor Steel Reinforcement Bars Of Approved Brands Of Different Diameters And Reinforcement For Rcc Work Including Cost And Conveyance Of All Materials, Labour For Uncoiling, Straightening, Cutting, Bending, Tying With 22G Binding Wire Etc. Complete 72 Solid Blockwork ( 30X20x15cm Size Blocks ) In Cm1:5For All Leads And Lifts Including Cost And Conveyance Of All Materials, Labour, Other Incidentals Like Scaffolding, Curing Etc. Complete. 73 Plastering With Cm 1:4, 12Mm Thick Floated Hard And Trowelled Smooth Including Cost And Conveyance Of All Materials, Labour, Curing Etc. Complete. 74 Dismantling Steel / Wooden Windows And Stacking The Dismantled Materials Within Csl Premises, Including All Labour, Tools, Conveyance Etc. Complete. 75 Providing And Fixing In Position Fully Glazedaluminium Supersliding Window / Ventilator With Lock System, Powder Coated Aluminium Heavy Section With Sliding Shutters Using Following Sizes Or Higher Available Size, 63.5 X 31.75 X 2Mm For Frames, 38.10 X19.5 X 2Mm For Shutter Interlock, Vertical And Horizontal And Plain Glass 4Mm Thickincluding All Fixtures Like Hinges, Locking Arrangements, Handles, Epdm Beadings Etc Including Cost And Conveyance Of All Materials, Labour, Other Incidentals Etc. Complete. 76 Servicing And Repairs To Damaged Shutters Of Glazed Aluminium Doors / Windows, Including Replacing Parts Such As Tower Bolt, Hinges, Sliding Window Lock, Rubber Beading, Door Closer Etc. Complete. ( Cost Of Parts Will Be Paid Separately. Measurement Will Be Taken Per Shutter. ) 77 Dismantling Tile Works In Floor Laid In Cement Mortar Or Tile Adhesive, Cleaning The Surface And Stacking The Dismantled Materials Within Csl Premises, Including All Labour, Tools, Conveyance Etc. Complete. 78 Supplying And Laying Vitrified Flooring Tiles Of Approved Brand, Colour, Size 600X600mm, Set Incm 1:3, 20Mm Thick And Adding Necessary Cement Grout For The Proper Binding Of The Tiles To Line And Level, Pointing The Joints With Coloured Cement To Match With The Tiles Including Cost And Conveyance Of All Materials, Labour, Other Incidentals Etc. Complete. ( Basic Rate Of Tile Is Rs. 900 / Sqm Excluding Tax, Conveyance, Loading & Unloading ) . 79 Supplying And Laying Ceramic Flooring Tiles Of Approved Brand, Colour, Set In Cm 1:3, 20Mm Thick And Adding Necessary Cement Grout For The Proper Binding Of The Tiles To Line And Level, Pointing The Joints With Coloured Cement To Match With The Tiles Including Cost And Conveyance Of All Materials, Labour, Other Incidentals Etc. Complete. ( Basic Rate Of Tile Is Rs.350 / Sqm Excluding Tax, Conveyance, Loading & Unloading ) . 80 Supplying And Laying Ceramic Flooring Tiles Of Approved Brand, Colour, After Clearing The Floor Properly, By Pasting With Chemical Adhesive ( Cerabond Or Weber Adhesive Of M / S Saint Gobin Or Myk Laticrete Tile Adhesive ) And Pointing The Joints With Coloured Cement To Match With The Tiles In Line And Level Including Cost And Conveyance Of All Materials, Labour, Other Incidentals Etc. Complete. ( Basic Rate Of Tile Is Rs. 350 / Sqm Excluding Tax, Conveyance, Loading & Unloading ) . 81 Providing And Laying 60Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand ( 6Mm Aggregate ) In Level Which Is Laid Over 200 Micron Polythene Sheetwith An 15 Cm Overlap In Joints Longitudinally & Transversely, Filling The Joints With Fine Sand, Concreting The Ends With 1:2:4 For Locking Etc. All Complete. 82 Dismantling All Types Of False Ceiling Work And Stacking The Dismantled Materials Within Csl Premises Including All Labour, Tools, Conveyance Etc. Complete. For Ceilings Like Calcium Calicate False Ceiling Individual Damaged Tiles Only Need To Be Dismantled. 83 Supplying And Fixing Calcium Silicate Ceiling Tile Of Size 600X600x15mm, Tegular Edged. ( Excluding Framework ) Only Individual Damaged Tiles Only Need To Be Replaced. Cost Is Inclusive Of Material, Labour, Conveyance Charge Etc. Complete. 84 Repairing / Refixing Of Pvc Or Grid False Ceiling Including Cost Of Labour For Removing And Refixing Of False Ceiling, Tools Etc. 85 Supply And Fixing Of Pvc False Ceiling With Skeleton Frame Work At All Heights Made Out Of Aluminium 1” T Sections In An Interval Of Not More Than 61Cm. The Perimeter Channels Will Be Fixed Along With The Roof With A Dimension Of 25 X 25 X 1 Mm With Wall Thickness Of 1.2Mm. The Main Channel Is Made At Aluminium T Sections Having Thickness, Of 1.2 Mm X 25Mm With Wall Thickness Of 1Mm. The Inter Mediate Channels Will Be Same And Will Be Fastened To The Roof Using 1.2 Mm Dia Gi Wire Hangers, At Closer Intervals. The Edge Profile‘S Made With 25 Mm X 25 Mm X 1Mm Aluminium Powder Coated ‘L’ Angle Section. The Joints Should Be Covered With Aluminium Powder Coated Key Gola Sections, With Pvc Sleaves Inserted Hence No Screws Will Be Visible. The Grid Work Will Be Covered By Pvc Materials Confirming. The Multi-Chambered Pvc Sections Having Overall Dimension Of 250 X 6Mm With Wall Thickness Of 0.8Mm And With The Help Of Selftapping Screw 13 X 4Mm, Necessary Cutout For Electrical Connection Shall Be Provided. Only Individual Damaged Pvc Panels Only Need To Be Replaced. Rate Is Inclusive Of Supporting Members Including Providing Additional Support Members From Truss According To The Purlin Spacing Available / Concrete Slabs & Grid Ceiling Members In The Damaged Existing Ceiling Tile Areas. The Rates Including Cost Of All Materials, Labour, Cost Of Welding Charges To Existing Steel Purlin, Joint Profile, Cornice, Other Incidentals, Etc Complete. ( Labourrate Includes Providing Necessary Openings Forelectrical Works. Mesurements Will Be Taken Laterally ) .The Height Of Tie Members Shall Vary And Rate Of The Same Is Inclusive In This Item. 86 Grid Ceiling :Providing & Installing To True Line And Level Commercial Type Suspended Modular Ceiling Suspended Using Suitable Support System At Every 1200Mm Intervals. Grids Width: 24 Mm Finished In Approved Shade ( White ) . The Main Runners & Cross Tees To Have Stab Installation System Made Of Corrosion Protected Galvanized Steel Or Approved Equivalent. Tile Type: Calcium Silicate Ceiling; Tile Size 600 X 600 X 15Mm Thick; Edge Detail: Tegular, Ceiling: Suspension System, Grid Member Sizes: Main Runners: 24 X 32 X 0.30Mm Or Nearest Available Size, Cross Tees: 24 X 24 X 0.30Mm Or Nearest Available Size, Perimeter Section: 24 X 27 X 0.40 Mm Or Nearest Available Size. False Ceiling Will Be Measured On Horizontal Plane Only. Horizontal Plane Measurements Are To Be Inclusive Of Vertical Drops, Edge Mouldings, Fascias Etc. All Extra Tiles Occupied By Lights And Diffusers To Be Returned To Department. Rate Is Inclusive Of Supporting Members Including Providing Additional Support Members From Truss According To The Purlin Spacing Available / Concrete Slabs & Grid Ceiling Members In The Damaged Existing Ceiling Tile Areas. Rate Quoted To Include Cost Of All Materials, Labour, Other Incidentals, Cost Of Welding Charges To Existing Steel Purlin, All Cutouts Required For Light Fixtures. The Height Of Tie Members Shall Vary And Rate Of The Same Is Inclusive In This Item. 87 Supplying And Fixing New Frp Lining To The Existing Pickling Tanks After Cleaning The Surface And Applying Frp Putty, Priming Coat Of Isopthalic Resin Applying Five Layers Of Fibre Glass Chopped Strand Mat-450 ( Each Layer Of 1 Mm Thick ) To Be Laid One After Another And Laminated With Isopthalic Resin, Catalyst And Accelerator Including Cost Of All Materials, Conveyance, Labour And Other Sundries Etc. Complete. ( Total Five Coats + Finishing Coat ) . 88 Supplying And Fixing Pvc Gutter 4Kg / Cm2 Up To 250Mm Dia With Gi / Ms Clamp @50Cm C / C Including Cost And Conveyance Of All Materials And Labour Etc.Complete. 89 Upto 250Mm Dia Pvc Gutter 90 315Mm Dia Pvc Gutter 91 Conducting Topograhic Digital Survey Of The Existing Crane Rail At Locations After Obtaining Work Permits And Submitting Plotted Drawings And Compact Disc For The Same. 92 Laying / Fixing Csl Supplied Roof / Deck Ladder Over Roofing Sheet For The Work Of Leak Rectification, Roofing Sheet Replacing Etc. Including Cost Of Labour & Conveyance, Charges Of Removing Roof Ladder After Work Etc. Measurements For Laying Roof Ladders More Than 6M Will Be Only Be Carried Out Under This Item. 93 Carrying Out Miscellaneous Works By Arranging Various Categories Of Labour. 94 Fitter / Welder 95 Man
Contract Date: Nov 30, 2023 Contract Value : 21.84 Lakh
Boards / Undertakings / PSU No of Bidders 2
47.
Petroleum and Natural Gas #1261755 AOC
Rate Contract For Tank M And I Jobs In Iocl , Bgr , Part-A: Tank M&I Jobs Group-1 ( Gq ) , Dismantling Of Floating/Fixed Roof Tank Retrieving All Existing Fittings , Instruments , Foam Seals , Side Railings , Dismantling Of Damaged Corroded Shell / Roof Of Welded Oil Storage Tank By Gas Cuttings/Cold Cutting Or Any Other Suitable Means As Directed By Engineer In Charge And Transporting Them To Storage Point/ Scrapyard As Designated Without Disturbing / Damaging Any Portion Of Existing Piping , Equipment , Tank And Complete In All Respect With All Labour , Tools , Machineries , Supervision Etc . Requirement Of Heavy Equipment To Be Envisaged By Engineer-In-Charge And To Be Arranged Separately , If Required , As The Same In Not Included In The Item Rate . Requirement Of Scaffolding To Be Envisaged And Decided By Engineer-In-Charge As Per Site Requirement And Scaffolding Item To Be Paid Separately . , Roof : Dismantling Of Complete Roof/ Structural/ Shell/ Course/ Truss: Retrieving All The Existing Fittings , Instrumentations , Side Rails , Etc . By Gas Cutting/ Cold Cuttings Directed By Inspection/ Site Engineer . And Shifting Of Dismantled Roof Plates , Structural Etc . To Ground ( Only Scrap ) To Transport And Kept Properly The Same In Scrap Yard After Taking/ Recording Weight . During The Entire Job All Safety Norms To Be Followed In Any Case . Note: The Measurement Of Dismantling , Shall Be Calculated Based On Actual Area Laid Of Complete Roof Plate Minus 10% Corrosion Correction . , Shell: Dismantling Of Shell Course Retrieving/ Removing Of Shell Plates . Retrieving All Existing Manholes/ Nozzles/ Fittings , Instrumentation , Side Rail Etc . By Gas Cutting/ Cold Cutting As Directed By Eic . Shifting Of All Scrap To Scrap Yard/ Designated Location As Per Eic After Taking And Recording Weight . During The Entire Shifting Job , All Safety Norms To Be Followed . Note: The Measurement Of Dismantling , Shall Be Calculated Based On Actual Area Of Shell Plate Replaced Minus 10% Correction Corrosion . , Bottom: Dismantling Of Bottom ( Annular ) Plates Completely: Dismantling Of Bottom ( Annular ) Plates , Job Involves Cutting Of Bottom Plateand Shell To Bottom Plate Welding , Jacking Of Shell . And Also Cutting Of Annular To Sketch Plate Cutting . Dismantling Of Bottom ( Sketch ) Plate: Dismantling Of Bottom ( Sketch ) Plates By Gas Cutting And Roof To Be Properly Supported And Handing Over To Civil Maintenance For Tank Bottom Foundation Repair . Shifting Of Roof Support As And When Required To Facilitate Repair/ Relaying Of Foundation . Note: The Measurement Of Dismantling , Shall Be Calculated Based On Actual Area Laid Of Complete Bottom Sketch Plate Minus 10% Corrosion Correction . , Restoration Of Storage Tanks Transportation Of Ms Plate From Storage Points To Worksite , Cleaning , Cutting In Required Sizes , Rolling , Edge Preparing , Laying Shell Courses / Roof Plates For The Storage Tanks And Partial Laying Above Existing Bottom After Bulged Portions To Be Cut And New Plate To Be Welded , Flushing With Existing Bottom And Continuous Welding , Installation , Fixing Of Various Types Of Manholes , Nozzles , Flanges , Gaskets , Orifice Assemblies , Tapping For Gauges And Thermowells Etc . All Types Of Fittings , Level And Other Fittings Retrieved During The Dismantling Of The Corroded Roof , Fixing Back The Side Railings Of Dismantled Along With The Corroded Roof Plates , And Pneumatic , Vacuum And Other Types Of Testing , Flushing , Cleaning , Pickling Of Welded Joints Where Required By The Specification And Completing All Such Works In All Respect For Restoring The Tanks To The Original Condition And Commissioning As Per Drawings , Specifications , Relevant Code ( Api-650/ Api-653 Is-803 ) And Instruction Of The Engineer-In-Charge And Inspection Manager . Note: The Ms Plates For Bottom , Shell , Roof , Extension Plates , Reinforcement Pads Plates For Shell Manholes , Foam Dam Will Be Supplied By The Owner As Per Drawing And Specifications . All Other Labour And Materials Etc . Shall Be Arranged By The Contractor At His Cost . Requirement Of Heavy Equipment To Be Envisaged By Engineer-In-Charge And To Be Arranged Separately , If Required , As The Same In Not Included In The Item Rate . Requirement Of Scaffolding To Be Envisaged And Decided By Engineer-In-Charge As Per Site Requirement And Scaffolding Item To Be Paid Separately . , Roof: Fabrication/ Erection Of Fixed/ Floating/ Fixed Cum Floating Roof From Store To Work Site , Cleaning , Cutting In Required Sizes , Rolling , Edge Preparation And Handing Over To Painting Agency And Recollection For Laying Shell Course/ Roof Plates ( Keeping Painted Surface In Side Tank ) And To Be Welded New Plates/ Structural/ Truss Etc . As Per Inspection Recommendations As To Develop Complete New Roof For The Tank After Installation Of Various Types Of Manholes , Nozzles , Flanges , Orifice Assemblies , Instrumentation Tapping For Gauges/ Thermo-Wells/ Walkways/ Platform For Operation Requirements Etc . , Fittings For All Required Valves Etc . All Such Articles , Which Were Retrieved Before Dismantling The Old Roof . Fixing Back All The Same In Repaired Condition If Not Usable; The Side Railing , All Jobs Related To Tank Roof Replacement To Be Completed Including All Ndt As Per Codes In All Respect For Restoring The Tank In Original Condition And Commissioning As Per The Drawing , Specifications , Relevant Latest Codes ( Per Api-650/653/Is:803 ) And To The Satisfaction Of Inspection/ Production And Engineer-In-Charge . , Shell: Installation Of Shell Plates Along With All Nozzles Connected To Inlet/ Outlet Lines , Drains , Roof Drain Connection As Per Original Drawing And All Other Existing Fittings , Instrumentations , Side Rails , Etc . To Bring Back The Tank In Original Condition And To The Satisfaction Of Inspection/ Operation And Engineer-In-Charge . All Weld Joints Conforming To Ndt , Such As Dp Test , Pneumatic Test; Joints Radiography Etc . As Per Code Api-650/653 And Is-803 Note: Radiography And Dp Test Shall Be Paid As Separate Item . , Bottom: Fabrication/ Erection/ Laying Of Bottom/ Annular Plates 10/14/16 Mm Thick: Transport Of Ms Plates From Store To Work Site , Fabrication , Erection , Overlaying And Welding Of Bottom/ Annular Plates Keeping Painted Surface Towards Bituminous Pad . Making Slot In Tank Shell , Insertion Of Annular Plate , Shell To Bottom Welding From Both Side Of Shell , Testing Of Butt/ Lap Joints By Soap Solutions Under Pneumatic Test , Chalk-Diesel Test Of Shell To Bottom Annular Plate All Around . Job Involves-Edge Preparation; Fixing Of Backing Strip; Welding; Ndt I . E . Performing Dp Test , Pneumatic Test; Joints Radiography Etc . Misc . Job Involves . Lifting Of Tank Shell By Jacking . Hydraulically Jack Up Of Tank Shell To Be Done In Case Of Annular Plate Replacement . All Weld Joints Preparation By Buffing To Facilitate Ndt , Shell Window Cutting ( Of Appropriate Size ) In 1St Shell Course For Insertion Of Bottom Plates And Reposition And Welding The Same After Completion Of Job . Welding Of Shell Window After Preheating The Plate . Proper Stiffening/ Support To Be Provided In Cut Out Plate To Prevent Deformation . All Jobs Related To Tank Bottom Replacement To Be Completed In All Respect For Restoring The Tank In Original Condition And Commissioning As Per The Drawing , Specifications , Relevant Latest Codes ( Api-650/653; Is-803 ) And To The Satisfaction Of Inspection/ Operation And Engineer-In-Charge . Note: Radiography And Dp Test Shall Be Paid As Separate Item . Fabrication/ Erection/ Laying Of Bottom Sketch Plates 6/8 Mm Thick: Transport Of Ms Plates From Store To Work Site , Fabrication , Erection , Overlaying , Edge Preparation/ Fixing Of Backing Strip/ Welding Of Bottom Sketch Plates Keeping Painted Surfac
Contract Date: Sep 16, 2021 Contract Value : 2.17 Crore
Boards / Undertakings / PSU No of Bidders 6
48.
Banking and Finance #24316 AOC
Supply Of Godrej Strong Room Door Class B Moradabad Installation Of Trtl Vault ( Strong Room ) Door ( Class-B ) With Exhaust Fan, Ventilator, V-Cage , Trtl Vault ( Strong Room ) Door ( Class-B ) With Exhaust Fan, Ventilator, V-Cage , The Vault ( Strong Room ) Door ( Main Door ) Dimensions And Specification Shall Be Strictly Adhering To Is 11188 ( Part-1 ) : 2014., Door Should Be Opened Right To Left Direction., Specification For The Strong Room Gate Are As Should Be Followed By Rbi Guidelines., The Door Shall Have Bis Label Of Class B Having Torch & Tool Resisting Capacity For Minimum 30 Minutes And Fire Resisting Capacity For A Minimum 30 Minutes., The Bidder / Oem Must Possess Valid Bis License To Manufacture And Supply The Aforementioned Trtl Door ( Class B ) ., All The Surfaces Of The Door Before Painting Shall Be Thoroughly Degreased And Cleaned Of Rust And Scales Preferably By 12 Tank Pickling Process And Treated Chemically To Prevent From Rusting., The Door Shall Be Painted Inside And Outside With An Anti-Corrosive Primer Followed By Two Undercoats Of Paints And Finally Painted With Quick Drying Paint, Resulting Into Minimum 300 Hrs. Of Salt Spray Resistance. ( Attach Certificate / Declaration ) ., The Main Door ( Class B ) Shall Consist Of Outer And Inner Mild Steel Plates Conforming To Is 2062:1992 For Plates Up To 20 Mm Thick Strongly Rimmed And Continuously Welded To Form A Single Structure And Tightly Enclosing A Solid Slab Of High Speed Drill Resisting And Oxy Acetylene Torch Resisting Material That Is At Least 50 Mm Thick., Door Frame: The Door Frame And Vestibule Shall Be Welded To One Piece Construction With A Minimum Thickness Of 10 Mm And Shall Grip The Concrete Wall., Rebate: The Rebate Of The Door Frame Shall Be Formed By Mild Steel Sections. The Vertical Rebates Shall Be Riveted Or Welded With The Side Members Of The Door Frame And Shall Conform To Dimensions As Specified By Is 11188., Clenching Mechanism: A Continuous Resilient Packing Shall Be Incorporated In The Frame And A Compression Mechanism For Clenching The Door Tight Shall Be Provided So As To Protect Against Admission Of Flood Water Or Liquid Explosives. In A Locked Position The Door After Clenching Shall Not Have Any Play In The Direction In Which The Door Opens., The Door Shall Have An Automatic Relocking Device For Each Key Lock Fitted In The Door Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosives Or By Other Means., Primary Lock Of The Door Shall Have Additional Relocking Device Which, Being Always On Guard, Shall Come Into Operation If Lock Is Dislodged By Explosive Or Any Other Means., The Lock Shall Be Dual Control Type And Have At Least 8 Active Levers Of Brass Of Minimum 1.2 Mm Thickness. There Should Not Be Any Dummy ( False ) Levers., The Bidder / Oem Must Be The Original Equipment Manufacturer Of The Locks Used In The Aforementioned Safe. ( Oem Must Give A Written Undertaking On Letterhead And Must Also Give An Noc To The Bank For Plant Visit If Needed ) , Lock Case: Should Be Minimum 2 Step Case Construction Covering Entire Jamb Area., The Lock Shall Be Fixed With At Least Four Bolts Of 8 Mm Diameter Such That Any Pressure Applied On The Bolts Either Directly Or Through Handle Of The Door, Is Not Transmitted To The Fixing Screw Of The Lock / Locks. All Working Parts Of The Lock Shall Have Corrosion Resistant Properties Capable Of Withstanding Exposure For 72 H In Standard Salt Spray Test With 5 Percent Salt Solution., Bolt Work: There Shall Be 6 Locking Bolts Each On The Vertical Edges Of The Door ( Front Edge & Rear Edge ) ., Hinges: Strap Hinges To Be Suitably Bolted To The Door Shutter. The Hinge And Pivot Should Be Such That There Is No Appreciable Friction Or Play For The Movement Of The Door. The Pivots Shall Have Arrangements For Lubrication And A Height Adjustment Bolt Is To Be Provided To Adjust Height Of Door Shutter., Grill Gate ( Inside ) : Ventilating Grill Gate Shall Be Made Of Mild Steel Angles, Plates Or Channels With Mild Steel Rods Welded In A Rigid Frame. The Grill Gate Shall Be Hinged In Strong Room Door Frame Such That It Opens Inside. An Unpick Able Dual Control Locking Device Capable Of Being Operated From Both The Sides Of The Door Shall Be Fitted In The Grill Gate., Emergency Door: The General Specifications Of Emergency Door Shall Remain As For The Main Door Except For Bolt Work. For Bolt Work, There Shall Be 3 Locking Bolts Each On The Vertical Edges Of The Emergency Door ( Front Edge & Rear Edge ) ., Limit Switch / Lighting Control: Vault Lighting Control Shall Be Fitted On The Main Door To Automatically Control The Electric Supply To The Vault.
Contract Date: Dec 02, 2021 Contract Value : 4.30 Lakh
Cooperative No of Bidders 2
Uttar Pradesh View Result →
TenderDetail
Loading tenders