View Bid Results For Phosphorous Brazing Tenders

We found 13 Bid Results related to phosphorous brazing tenders. You can find Contractor details who won phosphorous brazing tenders along with contract details in Bid awards announcements section.

Filters
Stage
12
1
Tender Publishing Platform
4
9
State / UT
8
4
2
2
1
1
1
1
1
Contract Value
1
1
11
Publish Date
0
0
0
0
0
Sector
5
6
4
1
1
1
Ownership
3
6
6
1
Within keyword
Active filters:
Showing 1–1 of 13 tenders matching your filters
1.
Defence #11206901 AOC
Tender For Provision Of Work Services For Sdr Facility In Abr Lab At 9Brd Afs Pune Under Ge Af Lohegaon - Taking down the existing surface batten type point wiring of aluminium/Copper for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. 2 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 3 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLSH PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board )ISI Marked (IS:14772) for housing switches / sockets all a specified and directed 4 (a) One Fan point/ light point controlled by one switch. 5 (b) One 3 pin socket 5 A on same board. 6 (c) One 3 pin socket 5 A on independent board. 7 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLSH PVC insulated single core 1100 volts grade & with one run of 2.5 Sqmm single core copper stranded FRLSH PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings / fixture etc and open recessed type Plastic Enclosure (Plastic Switch Board)ISI marked (IS 14782) for housingone 15 A Switch / socketsall a specified and directed 8 M/L for sub main wiring with two runs of single core 4.0 Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor1100 V grade with colour code and one run of 4 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cablefor continuous earthing complete in & including PVC casing & caping with all fttiing & fixtures all as directed and specified.(Note:- Two runs of 4 Sqmm copper cable & one run of 4 sqmm copper cable including PVC casing & caping shall be mesured and paid as one length) 9 M/L for sub main wiring with two runs of single core 6.0Sq mmFRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 6.0 Sq mmsingle core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in& including casing & caping all as directed and specified . ( Note:- Two runs of 6 Sqmm copper cable & one run of 6 sqmm copper cable including PVC casing & caping shall be measured & paid as one length ) 10 Supply and fix switch piano flush type 5 Amp one way, ISI Marked 11 Supply and fix Socket out let 2in 1, 5 pin 5 Amp ISI Marked 12 Supply and fix switch socket combination 5 / 16 A, 5 in 1, flush type,ISI Marked 13 S/F Fan Regulator electronic step type 100 W,ISI Marked complete as directed 14 Supply and fix ceiling rose surface type bakelite / PVCthree terminal 65 x 50mm. ISI Marked 15 Taking down existing VTPN DB grouted in wall and S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 16 Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and connecting to wiring complete all as specified and directed by Engr-In-charge. 17 Supply and fix MCB SPN B Curve 240 V, 32 Amps. complete all as directed at site. 18 Supply and fix MCB SP B Curve 240 V ,6 to 32 Amps complete all as directed at site. 19 M/L for providing earthing complete with galvanised steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, checknuts & washers of GI or steel and connecting to earth dolly all as shown in electrical plateNo. 3 of SSR Part I of 1991 & testing complete including 15mm dialight grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , funnel, wire mesh with GIwatering pipe etc. 20 Supply and fixing in replacement of double pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed 21 S&F of CEE Panel mounted receptacles 16 A, 3 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 22 S&F of CEE Panel mounted receptacles 16 A, 5 pole straight, IP 44 Protection,including Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts complete all as specified and directed. 23 S&F of CEE plug 16 A, 3 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 24 S&F of CEE plug 16 A, 5 pole straight, IP 44 Protection,Eclosure made of high quality plastic or AMELAN in aggressive atmosphere with high resistant to chemicals as well as high heat resistant contact carrier and nickel plated contacts, strain relief and protection against kinking, enclosure with thread lock and safety slide complete all as specified and directed. 25 S&F of Sub main wiringwith 4 X 6 sqmm single core cable FRLSH PVCinsulated unsheathed of copper multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 6 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 6 Sqmm & 1 length of 6 sqmm cable and PVC casing caping will be measured as one length). 26 S&F of Sub main wiringwith 4 X 10 sqmm single core cable PVCinsulated unsheathed of copper FRLSH multi strandard conductorcable , 1100 votls grade drawnin PVC casing caping and including PVC casing caping and insulated 1X 10 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dollycomplete all as specified and directed by Engineer-in-charge. (Note:- 4 lengths of 10 Sqmm & 1 length of 10 sqmm cable and PVC casing caping will be measured as one length). 27 Taking down carefuly copper strip of Size upto 32x6mm including pocelain/epoxy insulator, storing in safe custody for reuse and refixing the taken down copper strip as directed at site including supply and Fix of new epoxy insulator at a gap of 1 meter and brazing of copper strip with double nut and bolt with overlap of 3 cm complete all as directed by Engr-In-Charge. 28 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 6000K colour temperature with current electronic connections as directed. 29 Supply and fix MCB TPN 415 V, 32 Amps 10 KA C Curve in DB complete all as directed at site. 30 Supply and fix MCB TPN 415 V, 40 to 100 Amps 10 KA C Curve in DB complete all as directed at site. 31 M&L for making hole in Brick masonary / Stone masonary wall of any thickness and height of round shape and suitable for exhaust fan of 380mm dia and making good disturbed wall and painting distubed area as original complete all as directed. 32 Supply and fix exhaust fan, steel body heavy duty AC single Phase. 230V of size 380 mm sweep with, blades, and frame and louver complete all as specified and directed. 33 1. Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2TR having dual rotor inverter compressor, 100% copper IDU and ODU, installation kit with extra copper piping, connection electric cord, drain water pipe as per site requirement and incl MS Stand for outdoor unit fixng and core cutting in stone masonary wall if required for passing of refrigerant piping and cables etc and making good disturbed surfaces matching to existingcomplete all as specified and directed by Engr-In-Charge 34 Supply and fixing of voltage stabilizer for automatic operationsingle phase naturally air cooled indoor typefor input variationbetween 170V to 280V with outputVoltage 230v with accuracy +/-2.5% and of capacity 5 KVA completeall as directed. 35 Supply and laying HDPE DWC pipe 135 mm inner dia SN8 incl coupler on wall/ along ground/ along channel/ in trench/under roof/ along pillar or as directed complete. 36 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 300 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 37 S&F Vertical double door Distribution board TPN 8 way with busbarand consisting ofMCCB 4pole 160A 16KA - 1 NO complete including connecting LT cable and outgoing submain wiring etc and testing complete all as specified and directed by Engr-In-charge. (Note : Cost of MCCB 160A, 4pole, 16KA -01 Nos is included in quoted rates) 38 Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded copper conductor of size 35 Sqmm 3.5 Core laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix on wall etc all as specified and directed. 39 Supply install, test and commissioning of Powder coated LTpanel cubical Indoor type floor standing type compartmentalized in construction fabricated from CPRI approved manufacturer specified in particular specification and made out of 3 mm thick CRCA sheet & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB/ACB and TPN Copper bus bars , incomerand outgoing feeders .The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. Thecubicle shallhave bottom frame & dimension as required for panel & stand shall be made out of equal angle iron of size 50mm x 50mm x 6mm height 600mm. A detachable predrilled gland plate of thickness not less than 3 mm thickpowder coated should be used at thebottom for entry of armoured cableof adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. Copper extension link shall be provided at incomer & outgoing end of MCCB of rating 63 Amps & above. The panel shall be powder coated with 7 tank process of approved thickness complete including CTs, control wiring by 1.5Sqmm Wire, including provision of heat shrink sleeve on each cable core within panel, lugs, nut bolts, washers etc complete all as specified and 40 a) Copper bus bar 500 Amps for 4 pole-01 SETb) MCCB FP 320 Amps415 Volt 50 KA,Ics =100% Icu WITH thermal and magnetic setting type - 1 Nosc) MCCB FP 100 Amps - 415 Volt 16 KA,Ics =100% Icu- 5 Nos f) RYB Indicators - 1 Set and g)Digital 3 Phase Amp Meter and Voltmeter with selector switch - 1 SetNote - (i) The lay out drawing of the panel shall be got approved by the contractor before panel fabrication. 41 Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE(cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor of size 25 sqmm 3.5 core, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified. 42 Supply and fix Voltage stablizer for automatic operation, three phase , naturally oil cooled, inddoor type anddesigned for input variation between 300V to 480 V with accuracy + 2.5 % , IP55 Protection, 50 Hz, Unbalance type, copper wounded, matallic body duly powder coated, liftinghooks, digital display, relay controlled for smooth and silent operation with first filling of transformer oil upto specified level , with zero distortion waveform, sesitivity +/- 1%, overall Efficiency more than 95 % digital multifunction meterand speed of correction 8 volts per second and of capacity 30 KVA complete all as specified and directedNote: (a) Stablizer shall be free from hunting during automatic operation and No load losses shall not be more than 5% of rated output current.(b) Protection: (i) Overload short circuit protection at input end by MCCB 4 pole of suitable size as per recommendation of OEM - 01 Nos (ii) High / low voltage cutoff(iii) By pass arrangement - providing 01 No 4 pole on load changeover switch of suitable rating (iv) single phase sequence change protection.(c) Acceptance Test :- Testing of servo voltage stabilizer should be carried out as per BIS 9815 (Part-I) in OEM factory in the presence of rep of Accepting Officer and contractor/his rep. Contractor shall give 45 days in advance intimation with respect of date of testing. The following testing shall be carried out:(i) Physical Examination (ii) Insulation resistance (iii) High voltage test (iv) Leakage current test (v) Output voltage (vi) No load current (vii) Measurement of No load loss induced voltage testNote : Before make and specification approval type test report of OEM as per BIS 9815 Part - I should be produced by contractor for the specified capacity / next higher capacity of any voltage range from Govt Lab / NABL accredited lab. 43 Supply, installation,Boring, erection, testing and commissioningof Copper bonded(150 micron) MS solid rod electrode of dia 17.2 mm and 6 mtr long with high purity electrically conductive granular material having ultra low resistive value of 0.001 Ohm-m. Earthing Electrode shall bemade by embedding copper bonded MS Rod electrode in 100mm dia macronite conductive concrete made by mixing high purity conductive granularmixed with cement in the ratio2:1 (2 part of high purity electriclly conductive granular and 1 part cement and one litre of water per kg of mix ). The earthing electrode shall be augured inbore hole of dia not less than 100mm and6 Mtr depth. The conductive material shall confirm to BIS: 3043-2018. The rod shall be embedded in conductive concrete at factory with concrete having resistivity 0.040 Ohm-m. The top edge of the electrode shall comprise of plate provided with 04 holes for connections of the earthing strip,including brass nut bolts for connections of the strip the copper strip shall be duly brazed/welded with connection terminal of earthing rod, including FRP square chamber cover 300mm x 300mm x 250mm with top cover complete all as specified.All the material such as copperbonded MS rod and concrete mix shall be Ph nuetral, chemicaly inert and non corrosive complete all as specified and directed by Engr-In-Charge.i) The contractor shall submit type test report issued by the CPRI for high purity, electrically conductive earthings , confirms to rated short time withstand current20 KA per sec. ii) The factory made electrode shall be tested at factory and test report shall be submitted.iii) Factory testing of individual earthing shall be carried out in presence of rep of accepting officer and report shall be submitted.iv) The contractor shall obtain make approval for high purity electrically conductive granular duly by submitting certificates conforming to resistivity is 0.001 ohms by granular manufacturer.v) On installation of earthings at site, 04 to 05 Nos earthings shall be connected in grid to achieve less then 1 ohm resistance of grid, If desired resistance is not achived the contractor shall redo the same without any extra cost. vi) The contractor shall submit certificate issued by OEM of earthing electrode starting that The desired maintenance free earthing resistance less than 1 ohm. The year will be maintained for not less than 25 years. 44 M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plateNo. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.Note:-(i) Venders are bound to get earthing result upto 5 Ohm for single earthings and 3 Ohm with the grid of two earthing.Any additional work and material required to achive the required result is included in the cost quoted by the tenderer.(ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 45 M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mmby means of bolts, nuts, checknuts & washers of copper and connecting to test point, providing charcoal and common salt ,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs,including copper earth strip 20 x 3 mmwith GI protection pipe of 25 mm medium grade 7.5 meter long, etc complete all as specified.Note-- (i) Vendors are bound to get earthing result upto1 Ohm with grid of three earthings and 2 Ohm with grid of two earthing, 3ohm with single earthing, Any additional work and material required to achive the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with M&L for black cotton soil 1 cum. 46 S&F in repair of test point made out of gun metal or phosphorous bronze of size 75x50x5mm duly mounted on epoxy insulator 02 Nos.Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal block cover box made out of M.S sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer. 47 S & F copper earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc.and connecting with earthing test point oras required complete all as directed. Note: Earth work required shall be deemed to be included in quoted rate, nothing extra shall be paid on this account. 48 Excavation in trenches not exc 1.5 m wide andnot exc 1.5 m in depth and getting it out for laying of cable / pole etc. 49 Soft/loose soil 50 Hard/dense soil 51 Soft/disintegrated rock 52 Returning/ Refilling of excavated soil including spreading levelling and well ramming in layers for any type of soil. 53 Removing the surplus soil to a distance not exceeding 50 mtrs from the starting point and depositing at a height not exceeding 1.5 m above ground level. 54 M&L for Cutting the existing road precisely for laying of cable crossing pipe and making good the distubed surface of road as per original after laying of pipe and removal of debries complete all as directed.Note: The cost of making good is deemed to beincluded in quoted rate. 55 Supply and fixof MCCB FP 63 AmpsFixed type with breaking capacity16 KA with Sheet metal enclosure of 2 mm thick CRCA sheet single door with provision opening for incomming and outgoing cable/ submain including connections and testing for proper functioningincl taking out unserviceablecomplete all as specified and directed.
Contract Date: Feb 04, 2026 Contract Value : 35.23 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
2.
Defence #9609235 AOC
Tender For Additional / Alternator To Bldg. No P-51 (Or Md Accn), Provision Of Main Lt Panel With Three Phase Energy Meter In Dd Line And Provision Of 01 X Toilet Bathroom In Adm Area At Mil Stn Yol.; 1 Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each and removing from site, complete all as specified and directed. 2 Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but not exc. 4 Sqm each and removing from site, complete all as specified and directed. 3 Pressed steel frames of size 105x60mm for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate, 25x3mm flat iron 230mm long hold fast etc, complete all as specified and directed. 4 Pressed steel frames of size 125x60mm for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate, 25x3mm flat iron 230mm long hold fast etc, complete all as specified and directed. 5 PCC M-10, nominal mix, C-0, using 12.5mm graded mechanically crushed stone aggregate as in filling in door frame and mass concrete, complete all as specified and directed. 6 Flush door shutters 35mm thick, solid core construction with block board core and plywood face panels commercial type on both sides, complete all as specified and directed by Engr-In-Charge. 7 Factory made 2nd class hard wood (Sal) glazed and Skelton door shutters 35mm thick open rebated and prepared to receive glass gauge etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass or gauge etc., size of members of shutter as specified in clause 8.24 (a) of part-I, fitted to chowkats, complete all as specified and directed. 8 Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged, glazed skelton shutter (for glass and wire gauge)ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consiting two Nos sash bar of T-Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thickincluding cutting holes and making good dismantled portion in PCC M-15, type B-0 (04 Nos for each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces) and finishing the surfaces to match with existing including following fitting welded to frame shutter:- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf. (iii) MS tower bolt 150mm long - 2 No per leaf. (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge -1 No per leaf. (vi) Mild steel butt hinge of size 75mm x 12mm - 2 Nos per leaf. (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge. (viii) Fabrication & fixing arrangement as per drg No. CEPZ/ TD 06/07. Make : As per Appendix C. Note:-(i) Above referred drawing has not been made part of tender. The same can be seen in the office of GE during working hours on any working day. 9 M&L WPC (Wood Polymer Composit) Double Prelam Door Frame (Chowkhat) of Size 120mm x 50mm with a wall thickness of 5mm(+/- 0.25), made out of extruded 5mm(=0.25) mm thick PVC Sheet of Density 600kg/cbm manufactured y an ISO 9001-2015 certified company and by joining 3 Nos heat moulded PVC Sections. The high section of size 35 x35 mm shall be maid from plain colour PVC sheet of 5mm(=/- 0.25 mm) thickness. The inside section will be covered with 5mm thick PVC sheetC shape covering section of size 120mm x 50mm. At centretop position 5mm(+0.25mm) thick 50 x50 x50 mm pattam section should be pasted with solvent cemen adhesive to make double pattam of frame. The frame shall be mitre cut at two corners & joined with 4 nos of 150mm long L brackets of 19 x 19 mm MS square, Tube or fusion heat welding process. The two vertical door frames are to be reinforced with 25 x 25 mm MS square Tube of 19 gauge throughout the frame. The Door Frame shall be fixed to the wall using 8/100mm fischer screws. A minimum of 4 nos of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member etc. complete as per manufactures specification & direction of engineer-in charge. 10 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of solid core single Leaf Flush Door of 25mm thickness, lipped with 15mm (5mm x 3) thick x 30 mm width on one stiles and top rails & 10mm (5mm x 2) thick x 30 mm width on the other stiles & bottom rails. The inner panel Laminated with 2mm thick termite proof, water proof & fire resistant moulded PVC sheet with 2,4,6 raised panel design in different plain &/or prelam colors on one side after routing the mouldd design on flush door & 2mm plain and/or prelam PVC sheet on other side using rubber based adhesive on flush door & solvent cement adhesive on the lipping etc. complete as per direction of Engineer-in-charge, manufactures specification and drawing. 11 Sheet glass 3mm thick ordinary quality and glazingwith oil putty/aluminium beads in squares, not exc. 0.5 Sqm in each pane, complete all as specified and directed. 12 Figured glass, pin head type3mm thick and glazing with oil putty in squares n exc 0.5 Sqm in each pane, complete all as specified and directed. 13 Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks of glavanised wire staple fixed with stainless steel wire staples, fixed, complete all as specified and directed. 14 Applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surfaces of any description, exc. 10cm width or girth including preparation of surfaces, complete all as specified and directed. 15 Extruded aluminium alloy handles (ISI marked, fabricated type, anodised, of size 150mm, complete all as specified and directed. 16 Aluminium anodised, (ISI marked), barrel tower bolts of extruded section, length of bolt 200mm, fixed, complete all as specified and directed. 17 Butt hinges (ISI marked), medium weight, cold rolled, mild steel 100mm long, complete all as specified and directed. 18 Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 250mm with lipping frame to match, complete all as specified and directed. 19 Ordinary rat tail rod pattern springs 300mm, including roller and roller plate complete all as specified and directed. 20 S&F for Steel locking bolts with mild steel electrogalvanised plate and bright bolt not less than 10mm dia 100mm size all as specified. 21 Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165, complete all as specified and directed. 22 2nd classhard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as as specified and directed. 23 Prelaminted particle board 18/19mm thick interior grade prelaminated both side with decorative choice lamination and other side balancing white lamination and fixed with screws to timber frame work as on wall panelling cup boards shutters/shelves (sliding or fixed), complete all as specified and directed. 24 Extra over rates of 18/19mm thick block board or veneered particle board/ prelaminated board for external teak wood lipping, 6mm thick fixed with nails, complete all as specified and directed. 25 Continuous (piano) hinges, mild steel, bright finish or electrogalvanised Width of flaps (when open) in 40mm, complete all as specified and directed. 26 Extruded aluminium alloy handles (ISI marked), fabricated type, anodised, of size 75mm, complete all as specified and directed. 27 Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified and directed. 28 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. 29 Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. 30 Non skid, Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. 31 Non skid, Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. 32 Non skid, Premium class Igrade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, as in skirting, dado etc . set and jointed in neat cement slurry and includingincluding 10mm thick rendering in cement mortar (1:3) including necessary cutting as per site requirement complete all as specified and directed. including necessary cutting and waste as per site requirement pointed in white or coloured cement to match, complete all as specified and directed. 33 Glazed coloured tiles of size 450x350x7mm thick as in vertical surfaces such as jointed in neat cement slurry and pointed with coloured cement to match and including 10mm thick plastering in cement mortar 1:3 (1 cement : 3 coarse sand), complete all as specified and directed. 34 Machine cut kota stone slab flooring 18-20mm thick of size not less than 550 mm X 550mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC sub base, complete all as specified and directed. 35 Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. 36 Plain cement concrete M-15, nominal mix, type B-0, using 12.5mm graded mechanically crushed stone aggregate as inflooring, 25mm thick, surface finished even and rough to receive top finish or chamfering of RCC chajja with proper slope to drain off storm water surface, complete all as specified and directed. 37 Plain cement concrete M-10, nominal mix, type C-2, using 40mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5cm deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), complete all as specified and directed. Note:- The unit rate include for use of form work (straight or curved). 38 Demolition of cement concrete (un-reinforced) of any description and any position not otherwise specifically provided for, including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. 39 Plain cement concrete 1:5:10, nominal mix, type E-2, using 40mm graded mechanically crushed stone aggregate as in sunken floors, filling and mass concrete, complete all as specified and directed. 40 Water proofing treatment of sunken floor using SHALIURETHANE- BTD OF STP MAKE OR EQUIVALENT as approved by GE, high solid content single component water based liquid applied elastomeric water proofing membrane as ASTMC 836 and ASTMD 6083, thickness of the membrane shall be 1.5mm, having solid content of more than 80% elongation of 500+(-) 50%, laid over reinforcing layer on non woven geo-textile mesh of 40/50, 50 gms, including applying self primer coat by diluting with 1:1 ratio @ 0.4 kg per sqm and surface including 10 mm thick 1:3 plaster including cleaning of existing treatment complete all as specified and directed 41 Rendering cement plaster 10mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers ( 5mm thick first layers and 5mm thick 2nd layer) mixed with WPC @ 3% weight of cement on fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and as directed by Engr-In-Charge. 42 Plain cement concrete M-15, nominal mix, type B-1, using 20mm graded mechanically crushed stone aggregate as in sunken floor, 25mm thick, surface finished even and fair, complete all as specified and directed. 43 Mild steel galvanized iron water tubing 32mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. as in spout of sunken floor, including taking down old pipe, complete, all as specified and directed. 44 75mm thick Plain cement concrete M-10 nominal mix, C-2, using 40mm graded mechanically crushed stone aggregate as in sub base flooring, complete all as specified and directed. 45 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. 46 Dismantling stone slabs and tiles of any description or thickness, laid bedded and pointed in any mortar in floors, aprons etc.including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. 47 Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for, including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. 48 TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. 49 TMT steel bars 5 to 10mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips as in stirrups, spacers and binders, complete all as specified and directed. 50 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping)etc. for fair finished flat surfaces of concrete, complete all as specified and directed. 51 Marble 18 to 20mm thick, green marble, (table rubbed and polished and moulding of outer edges) as in kitchen cooking platform /shelf and verticle surfaces duly machine cut in skirting /dado and like laid over and including 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade green marble type, complete all as specified and directed. 52 Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, including formwork, complete all as specified and directed. 53 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations 54 Dismantling and breaking up PVC drain pipes 75/110mm dia, fixed to walls, laid in floors or in trenches and removal of demolished materials from the site, complete all as specified and directed. 55 PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75mm, fixed, complete all as specified and directed. 56 PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors, trenches, of bore 110mm, complete all as specified and directed. 57 PVC (SWR) pipes single socketed, in any length with rubber ring joints, in floors, trenches, of bore 75mm, complete all as specified and directed. 58 PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 110mm, complete all as specified and directed. 59 PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 75mm, complete all as specified and directed. 60 PVC (SWR) junction single, (Single T) equal or unequal, 75mm bore, provided with oval access door, fixed in repair, complete all as specified and directed. 61 PVC (SWR) junction single, (Single T) equal or unequal, 110mm bore, provided with oval access door, fixed in repair, complete all as specified and directed. 62 PVC (SWR) bends any radius, 110mm bore jointed with solvent cement (fitted with or without oval access door), fixed in repair, complete all as specified and directed. 63 PVC (SWR) bends any radius, 75mm bore jointed with solvent cement (fitted with or without oval access door), fixed in repair, complete all as specified and directed. 64 PVC (SWR) vent cowl 110mm bore fixed in repair, complete all as specified and directed 65 Rotational moulded polyethylene water storage tank 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including PVC float ball valve 20mm dia epoxy coated aluminium rod with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, complete including taking down old tank and removng to store all as specified and directed. 66 Brass chromium plated Wall mixer with provision of long bend pipe with connecting legs and wall flanges screwed down for iron pipe and fixed, complete all as specified and directed. Make:Cat. No.: F2002401 of CERA orequivalent in makes specified in Appendix C. 67 Brass CP sink mixer swan neck for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed. Make:Cat. No.: F1020501of CERA or equivalent in makes specified in Appendix C. 68 Chromium plated centre hole Mixer for Wash hand basin for mixing hot or cold water with 450mm braided connection pipe (without pop-up) screwed for iron pipe, complete all as specified and directed.Make:Cat. No.: F12002461 of CERA or equivalent in makes specified in Appendix C. 69 Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, snow white, with Cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate and making connection to trap complete all as specified, fixed in repair, complete all as specified and directed. Cat. No.: CABLE 3020105of CERA or equivalent in makes specified in Appendix C 70 Supply and fixed in repair PVC valveless, crystal white, syphonic action type flushing cistern 10 litres capacity low level with inlet, ball valve, float and handlewith brackets including 32mm dia PVC long bend flush pipe 90cm long snd 15mm dia PVC connection 600mm with CP brass coupling nuts and PVC washers at both ends, fixed, complete all as specified and directed. 71 Wash basins, Vitreous China of size 450mmx300mm, crystal white and including cutting for and pinning on ends of brackets, excluding tap, waste, chain & plug but including brackets fixed in repair, complete all as specified and directed. 72 Polyethlene and unplastcised PVC pipe, 32mm dia Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm all as specified and directed. 73 Sink with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connectingunion to pipe, including 40mm dia waste pipe & CP waste coupling, overall size 915mm x 460mm bowl size 405mm x 355mm x 178 mm, Cat No Blue Star SSSB-52 Silver Shine or overall size 940mm x 455mm of make Cera (cat No B4622101- Gloss finish Diana Lite)fixed in repair complete all as specified and directed. 74 Sheet glass shelf assembly 55cm long consisting of 5.50mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, selected quality as approved by GE, fixed in repair, complete all as specified and directed. 75 Chromium plated brass shower rose, fancy type (as approved by GE/Engr-In-Charge), 125mm size with shower arm, chromium plated, 195mm longh with bend of 45 degree with flange suitable for 15mm bore pipe with or without swivel joint fixed to pipe, Make : Cat. No.: F7020306ABof CERA or equivalent in makes specified in Appendix C fixed in repair, complete all as specified. 76 Angle/stop valve, cast copper alloy, fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle,screwed both ends for 15mm bore iron pipe or for unions and fixed in repair, complete all as specified and directed. Make : Cat. No.: F2002201of CERA or equivalent in makes specified in Appendix C 77 Stop valve, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed in repairs, complete all as specified and directed. Make : Cat. No.: F4060103 (Concealed part & F2002751 (Exposed part)of CERA or equivalent in makes specified in Appendix C 78 600mmx450mm bevelled edge looking mirror of selected quality with 6mm thick polished glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers fixed in repair, complete all as specified and directed. 79 Bib taps, fancy type 15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, chromium plated screwed for iron pipe or for brass ferrule and fixed in repairs, complete all as specified and directed.Make : Cat. No.: F2002151of CERA or equivalent in makes specified in Appendix C 80 PVC connection 15mm size with PTMT nuts at both end 600mm long, complete all as specified and directed. 81 32mm or 40mm Waste coupling, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed in repair, complete all as specified and directed. 82 Soap dish, chromium plated, fixed to plugs with chromium plated, brass screws, fixed in repair, complete all as specified and directed.Make : Cat. No.: F5003106of CERA or equivalent in makes specified in Appendix C 83 Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) and fixed in repair, complete all as specified and directed. 84 Taking down cement plaster on brick or stone walls, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. 85 Rendering cement plaster 20mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) on internal fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. 86 Rendering cement plaster 20mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers on fair faces of brick or stone walls finished even and smooth without using extra cement, mixed with WPC, complete all as specified and directed.Note : Supply only Water proofing compound shall be measured and paid for seperately. 87 Rendering cement plaster 10mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) on ceiling surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. 88 Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over & including 2mm thick wall care putty, complete all as specified and directed. 89 Preparation of old treated plastered surface of wall by complete removal of existing treatment and applying two coats of oil bound distemper over & including 2mm thick wall care putty, complete all as specified and directed. 90 Preparation of new plastered or unplastered surfaces of wall to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. 91 Preparation of old plastered or unplastered surfaces of wall including complete removal of existing treatment and finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. 92 Material and Labour for waterproofing of exterior walls, including complete removal of existing plaster including raking out joints and applying two coats of acrylic polymer modified high performance coating (Smartcare Ultra Block 2k). The treatment shall be done from ground level and providing 15mm thick cement plaster in CM 1:4 finished even and smooth all as directed. Make: ASIAN PAINTS/BERGER/NEROLAC 93 Preparation of new plastered surfaces of ceiling with 2mm thick wall care putty and applying one coat of oil bound distemper, complete all as specified and directed. 94 Preparation of old treated plastered surfaces of ceiling by complete removal of existing treatment, applying 1mm thick layer of wall care putty where required and one coat of oil bound distemper, complete all as specified and directed. 95 Taking down cement plaster/decayed concrete from RCC roof projections/upward parapet walls/down facia/soffits and fins of RCC chajjas/beams/columns/balconies etc. Supply and fixing by means of nailing wire netting of galvanised wire 1.40mm dia and mesh size 20mm and brushing neat cement slury with 3.00 Kg of cement/sqm and M&L for 20mm thick cement rendering in two layers of 10mm each (top/final layer shall be rendered after final setting of under layer) in CM 1:3 on concrete surfaces including scaffolding at a height upto 7.00 mtrs ect, complete all as specified and directed. 96 Taking up or down 15mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. 97 Taking up or down 20mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. 98 Taking up or down 25 mm to 32mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. 99 Supplying and laying of CPVC pipes 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 100 Supplying and laying of CPVC pipes 32mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 101 Tank Adaptor CPVC pipes of 32mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. 102 Union for pipes of CPVC 20mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. 103 Female Brass Threaded Adaptor (FTA/ FBTA) for CPVC pipes of 20mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. 104 Brass Elbow for pipes of CPVC 20mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. 105 Brass Elbow reducer (3/4 X ½) for CPVC pipes of 20mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. 106 Brass Tee for pipes of CPVC 20mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. 107 Taking up or down 25 mm to 32mm bore, steel tubing and connections, including cleaning for refixing or removal from site and refixing on same or new position complete all as specified and directed. 108 Supply only intergal water proofing compound, complete all as specified and directed. 109 Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick walls, complete all as specified and directed. 110 Plain cement concrete M-15, nominal mix, B-1 using 20mm graded mechanically crushed stone aggregate as in lintels upto 1.50 metre clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, chamfered angles and throating, complete all as specified and directed.Note :- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately. 111 Plain cement concrete M-10 nominal mix, type C-1 using 20mm graded mechanically crushed stone aggregate as in surface channel and drains, complete all as specified and directed. 112 Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches, pillars, including removal of debris to a distance exc 1.5 km but n.exc 2 Km, complete all as specified and directed. 113 Walling random rubble masonry with best quality locally available stone, uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. 114 All as per item No. 113 above but except stone. 115 Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. 116 Brick work with old sizefly ash bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. 117 S&F in repair 25mm dia powder coated mild steel, chromium plated curtain rod including brackets, complete all as specified and directed. 118 Rolled sections as in Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240s, steel work, complete all as specified and directed. 119 Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe.290 Gde E-165, steel work, complete all as specified and directed. 120 S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 121 S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 122 Preparetion of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. 123 Plain cement concrete 1:4:8, type D-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed. 124 Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, all as specified. 125 Reinforced cement concrete 1:2:4 type B-1, ( using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, all as specified. 126 Reinforced cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintel over 1.50m span, complete all as specified and directed. Note:- Reinforcement and form work shall be measured and paid separately. 127 Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for roughly finished flat surfaces of concrete, all as specified 128 Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for roughly finished flat surfaces of concrete, all as specified. 129 Formwork to sides of pillars, posts, struts, piers, columns and stanchions, for roughly finished square,rectangular or polygonal surfaces of concrete, all as specified. 130 Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. For fair finished flat surfaces of concrete, complete all as specified and directed. 131 Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. 132 Hardcore of broken stone or boulders of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed. 133 Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) on internal fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. 134 Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers on fair faces of brick or stone walls finished even and smooth without using extra cement, mixed with WPC, complete all as specified and directed.Note : Supply only Water proofing compound shall be measured and paid for seperately. 135 Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat ofchalk whitening, complete all as specified and directed. 136 Applying two coats of cement base paint on newly plastered or previously undecorated wall surfaces over one coat of alkali based primer including preparation of surface, tint and shade as approved by Engr-in-Charge, complete all as specified and directed. 137 Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete, all as specified 138 Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, anti-syphonage pipe complete including necessary fittings, fixed, complete all as specified and directed. 139 Wash basins, Vitreous China (Flat back) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450mm long PVC connections 15mm size long with CP coupling nuts at both ends, waste pipe of polythylene of low or high density or PVC of 32mm dia, chain and plug, porcelain stopper, and fixed, complete all as specified and directed. 140 Brass Chromium Plated, Tubular towel rail, 20mm dia, D type, 60cm long between flanges, with brackets, fixed with chromium plated screws, fixed in repair, complete all as specified. 141 Rotational moulded polyethylene water storage tank 500 Ltrs capacity (cylindrical vertical with closed top) three layer, hoisted and fixed in position including PVC float ball valve 20mm dia epoxy coated aluminium rod with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, complete all as specified and directed. 142 Gun metal, globe or gate valves, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 20mm bore iron pipe or for unions and fixed complete, all as specified. 143 Mild steel galvanized iron water tubing 15mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. Fixed to wall or ceiling or laid in floor, complete all as specified and directed. 144 Mild steel galvanized iron water tubing 20mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. fixed to wall or ceiling or laid in floor, complete all as specified and directed. 145 S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms, complete all as specified. 146 Damp proof course 25mm thick cement mortar 1:2 to horizontal or vertical surfaces including necessary formwork, complete all as specified and directed by Engr-In-Charge. 147 Factory made solid PVC Door/window/ventilator Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges shall be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No 180 of MES SSR 2020 Part-II, complete all as specified and directed. 148 Factory made fully glazed PVC (frosted/ground/obscured) window/ventilator shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; complete all as specified and directed.Note:- Glass gauges inclusive of quoted rates. 149 Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site, Sheet No 1/1), complete all as specified and directed. 150 Aluminium anodised, (ISI marked), barrel tower bolts of extruded section, length of bolt 150mm, fixed, complete all as specified and directed. 151 Chromium plated over headshower rose, 150mm x 150mm size square shape single flow suitable for 15mm bore pipe with rapid cleaning system, complete all as specified 152 Taking down point wiring with aluminium/ copper conductor for light point, fan & socket point/ power point etc. complete including switches, sockets, holders, (batten or pendent type), ceiling rose, switch board, bell/buzzer, bell push, and making good to the disturbed surfaces of wall/ floor etc. to match with existing surfaces including white wash/ colour wash/ distempering to match with existing wall/ floor/ ceiling finishes, complete all as specified and directed. 153 Taking down submain wiring any type and any size and making good disturbed surface by using cement mortar, white cement, putty etc. and match with existing surfaces of walls, floors etc., complete all as specified and as directed. 154 Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surfaces, complete all as specified and directed. 155 M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and includingconcealed PVC conduit(ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable sizeincluding concealedMS pressed steel (Modular sunken box) terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and Modular cover plate as top cover (ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/Exhaust fan point controlled by one switch, complete all as specified and directed. Note : i)Wiring Colour code i.e. Red/Yellow/Bluefor Phase, Black for neutral and Green for earth shall be maintained.ii) Rate of cutting chases, cement plaster, white wash and making surface good as existing surface included in quoted rate.iii) Point wiring is considered for Modular Switches and sockets. Rate of Metallic Sunken box and modular sheet cover plate and other connected accessories required for modular point wiring included in quoted rate.iv) Rate of modular switch and sockets will be paid seperately under relevant item. 156 All as per serial item No 155 above, but for ceiling fan/ exhaust fan/ wall fan controlled by one switch 6 Amp, SP, ony way, 240V, complete all as specified and directed. 157 All as per serial item No 155 above, but for one 3 pin 5 Amps socket outlet on the independent board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. 158 All as per serial item No 155 above, but for one 3 pin 5 Amps socket outlet on the same board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. 159 All as per serial item No 155 above, but for bell/buzzer point controlled by one bell push, 240 volts, complete all as specified and directed. 160 All as per serial item No 155 above, but for one light point controlled by two way switches, complete all as specified and directed. 161 All as per serial item No 155 above, but for 5 pin 15 amps socket out let on independentwith 2.50 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 2.50 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed. 162 S & F for modular switch 6A one way, single module, complete all as specified and directed. 163 S & F for modular switch 16A one way 16A one way with indicator, single module, complete all as specified and directed. 164 S & F for modular bell push 6A, single module, complete all as specified and directed. 165 S & F for modular switch two way 6A, single module, complete all as specified and directed. 166 S & F for modular socket for 6A 2/3 pin combined, 2 module, complete all as specified and directed. 167 S & F for modular socket for 6A/16A 3 pin combined, 2 module, complete all as specified and directed. 168 S & F infor lamp holder polycarbonate body (Metal ring) with back bakelite plate suitable for batten fittings, complete all as specified and directed. 169 M & L for ceiling rose 65 x 50mm three terminals, fixed, complete all as specified and directed. 170 Supply and fixing electronic bell ding-dong AC 230 Volts single pole, complete all as specified and diercted. 171 Supply and fiximgr Switch piano6 A SP 230 Volts 2 way, complete all as specified and directed. 172 S&F Socket outlet 2 in 1, 3 pin 6 Amps Flush type, complete all as specified and directed. 173 S&F Switch Socket combination outlet 2 in 1, 3/5 pin 5 and 15 Amps flush type, complete all as specified and directed. 174 Taking down carefully ceiling fan/exhaust fan any size/make with cable and all accessoreis removing from site to store for repair/overhaulling, complete all as specified and diercted. 175 Supply and fixed high speed stepped type electronic fan regulator 120W, 230 volts, complete all as specified and directed. 176 Dismantling of ceiling fan 1200mm sweep, removing burnt winding and Material and labour for rewinding the same with supper enamelled copper wire of existing size, gauge and turns including cleaning the slots properly and testing, complete all as specified and diercted. 177 Material and labour for one coat of synthetic enamel paint in situ by spray machine of ceiling fans any size/any make complete including filling cavities with filler, cleaning all dust etc and writing MES Nos, complete all as specified and diercted. 178 Supply & fixing bearing of ceiling fan 1200mm sweepas per existing bearing including necessary greasing, complete all as specified and directed. Make:-NBC/SKF/FAG/Norma 179 Supply & fixing in repair pair of three blades of 1200mm sweep ceiling fan, complete all as specified and directed. 180 Supply & fixing in repair top and bottom canopy of plastic with steel screw suitable for rod for fan of 1200/ 1400mm sweep, complete all as specified and directed. 181 Supply & fixing in repair down rod 15mm bore, 600mm long fixed one end with mild steel U clamp, nut, lockable bolt, rubber reel, lock pin and other end having threaded/ drilled hole end, suitable nut, bolt, split pin and check nut or aluminium clamp duly white painted suitable for all size and makes of ceiling fan, complete all as specified and directed. 182 Hanging only ceiling fan after checking serviceability of safety pins, clamps, rubber bushes, nuts, bolt, canopy and electric connections, making connections with fan including provision of cable for connection, complete all as specified and as directed by Enge-In-Charge. 183 M&L for painting with one coat of synthetic enamel paint (black) using spray machine painting on the surface of exhaust fan of size upto 300mm sweep (including louvers and other parts of exhaust fan) complete after preparation of surface i.ecleaning, washing of surfaces filling cavities with filler, cleaning dust and dirt, complete all as specified and directed by Engr-in-Charge. 184 Dismantling of exhaust fan 300mm sweep, removing the burnt winding and Material and labour for rewinding the same with supper enamelled copper wire of existing size, gauge and turns including cleaning the slots properly and testing, complete all as specified and diercted. 185 Supply & fixing in repairofsteel blade suitable for exhuast fan upto 300mm/600mm sweep, complete all as specified and directed. 186 Fixing only exhaust fan of any size/make upto 600mm sweep after checking serviceability of nuts, bolt and electric connections, making connections to fan including provision of cable for connection, complete all as specified and as directed by Enge-In-Charge. 187 Supply and fixing in replacement of unserviceable condenser ISI marked 2.5 mfd, complete all as specified and diercted. 188 Supply and fixing in replacement of unserviceable condenser ISI marked 3.15 mfd, complete all as specified and diercted. 189 Supply and fixing for AC Ceiling Fan, single phase, 230 volts, 1200 mm sweep includinggrouting the ragged bolts in wall, fixing the frame on the exhaust side and connecting up with PVC insulated three core 1.50 sqmm copper cable from ceiling rose to exhaust fan, complete all as specified and diercted. 190 Supply and fixing for AC exhaust fans, Steel body, with louver shutter, single phase, 230 volts, 50 Hz, 1200 RPM, copper winding 300 mm sweep including grouting the ragged bolts in wall, fixing the frame on the exhaust side and connecting up with PVC insulated three core 1.50 sqmm copper cablefrom ceiling rose to exhaust fan, complete all as specified and diercted. 191 Taking down carefully storage type water heaters (Geyser) of any type and make of capacity upto 50 litres, after disconnecting their electrical and water connections.De-scaling the inner container, heating element, base assembly using diluted hydrochloric acid and cleaning thoroughly.Filling the inner container with water and detecting leakage including brazing as required to stop the leakage, if any, reassembling the geysers after replacing the u/s spare parts, filling water and testing the geysers by applying pressure by means of hand/foot operated pump, to ensure leak proof. Refixing geyser in the same original position/location and making the electrical/water supply connections incl testing on completion, complete all as specified and diercted. (Note : Items required to be replaced will be measured and paid separately under relevent items of the Schedule) 192 Supply and fixing Geyser Indicating lamp as per sample, complete all as specified and diercted. 193 Supply and fixing Thermostat rod suitable for Geyser 25/35/50 ltr, complete all as specified and diercted. 194 Supply and fixingGeyser Element 1000/1500 Watt. Make:Remson/Microking, complete all as specified and diercted. 195 Supply and fixing Geyser connection pipe 12/18 long with sockets on both ends, made of steel, complete all as specified and diercted. 196 Material and labour for Apparatus plate suitable for 25/35/50 ltr geyser all as per sample, complete all as specified and diercted. 197 Material and labour for painting of geyser of any size at site, white in colour including removing and refixing in its original or any other position properly, complete all as specified and diercted. 198 Supply only with replacement of inner container fabricated out of copper plate of 1.3 mm thick as per the existing size and suitable for up to 50 lts capacity vertical type geyser of any make as per the existing, complete all as specified and diercted. 199 S&F in replacement, insulating materials (new glass wool) fixed/punned properly in existing geysers of capacities 25 to 50 ltrs, complete all as specified and diercted. 200 M & L forLED tube light fitting 20 watt, 6000 K, 220 volt, decoarative type complete with driver, holders, and LED tube of 20 watt complete with all accessories internally pre wired battenincluding connecting up with three core twisted flexible copper conductor cable ofsuitable size from ceiling rose to connector of light fitting including mounted on PVC square block, complete all as specified and diercted. 201 M & L forLED light fitting mirror type with high output diffuser 2 feet, 10 watt, 6000 K, 220 volts, AC decorative type with extruded polycarbonate having efficiency 120 lumens /watt with driver holder including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and diercted. 202 S&F in repairLED tube light fitting inverter type 1x 20 W, 230V, LEDtube light fitting, 4 batten shatter resistant cool day white, environment friendly, energy efficient ready to use completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizeincluding dismantling of unserviceable tube light, complete all as specified and directed. 203 Supply and fixing 12 Watt Led Bulb, 6500K, 2000lm, 230 volts, 50Hz, complete all as specified and diercted. 204 Supply and fixing LED security light of capacity 45 watt, 230 volts, 5700K, housing made of die cast aluminum with street optic lens with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.50 sqmm from ceiling rose to security light drawn through GI light grade security light bracket not less than 1.50 mtrs in length alongwith fixing on wall, complete all as specified and diercted. 205 S&F LED tube light fitting integral type 1x 10 W,230V, ultra slim square profile LED lighting fixture with extruded polycarbonate, environment friendly, energy efficient ready to use completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizeincluding dismantling of unserviceable tube light, complete all as specified and directed. 206 S&F LED tube light fitting integral type 1x 20 W,230V, ultra slim square profile LED lighting fixture with extruded polycarbonate, environment friendly, energy efficient ready to use completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizeincluding dismantling of unserviceable tube light, complete all as specified and directed. 207 Supply and fixing security light 35 Watt New generation energy saving and environmental friendly long life LED Bldg security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having Top Opening seperate toughtned glass/verminproof driver compartment, SPDs with IP66 protectionconnecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of size 32 mm dia length 1.2 mtr along with clamps, complete all as specified and directed by Engr - in - Charge. 208 Endura Pearl 35 Watt new generation energy saving and environmental friendly long life LED Bldg security light made up of pressure die case aluminium housing with high power LED as lighting source an lens enbedded PC cover having TOP opening seperate toughted glass/verminproof driver compartment, SPDs with IP66 protenction and impact rresistancee of IK07 connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of suitable size, Make : Havells HSN Code-8537 or equivalent in Crompton/ Wipro/ Bajaj/Philips. 209 S & F for MCB SP 6 to 32 amps 240 Volt,10 KA, B series, complete all as specified and diercted. 210 S & F for MCB SPN 32 to 40 amps 240 Volt, 10 KA, B series, complete all as specified and diercted. 211 S & F MCCB four pole 125 amps adjustable type, 415 volts, 50 Hz ,breaking capacity, 16 KA including making all connections using bottle /pin copper thimbles, complete all as specified and diercted. 212 Supply and fixing sheet metal enclousre for DBs when MCB to be used double door powder coated factory made flush fixed complete with 200 amps rated bus bar 240 volts single phase 12 ways, complete all as specified and diercted.Note: MCBs shall be measure and paid seprately. 213 S & F of sheet metal enclosures distribution boards, double door, VTPN, 415 volts 4 ways, as per IEC 61439-3, degree of protection IP-43 (one incoming three phase & twelve out goings single phase) for MCCB & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed for the following:-(a) MCCB FOUR POLE 160 amps, AC,415 VOLTS25 KA=01 No (for incoming).(b) MCB SP 06- 40 amps = 12 Nos (for outgoings) complete with 125 amps fully insulated copper bus bar for each phase and neutral link, prefitted masking sheet fixed flush in wall including chases wall for fixing DB, complete all as specified and diercted.Note :- (i) TheDB shall be VTPN seriesof Make : Indoasian Cat No 811888, or Eqvlmake of L&T/ ABB/legrand. (ii) Connection of the MCCBs/ MCBs with cableshall be made through appropriate size pin /bottle type thimble properly crimped.(iii)All the vacant holes of the DB shall be provided with blank plates of appropriate size. (iv) Double continuous earth wire shall be provided for each three phase DB from earthing mains duly.(v) Cutting chasing shall be part of job at no extra cost.(vi) MCCB & MCB shall be measured and paid seperately. 214 Supply and Fixing sheet metal enclosure with socket plugtop with MCB of a two pin and earth plug and a socket complete with one double pole MCB of 20 Amps rated, complete all as specified and directed. 215 Sheet metal enclosures factory made flush fixed for DBs when MCBs to be used, single pole and neutral (double Door powder coated), 4 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed. 216 Sheet metal enclosures factory made flush fixed for DBs when MCBs to be used, single pole and neutral (double Door powder coated), 8 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed. 217 M & L for submain wiring in and including PVC conduit 1.8 mm thick, 20 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 6 sqmm (FRLS) and one run of PVC insulated, unsheathed multistranded copper conductor 6 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM).Note: (a) Insulation test of point wiring to be carried out on completion of work.(b) Proper colour coding is to be maintained. (Ph-Red, N-Black,Earth- Green)(c) Two runs of single core cable with one run of earth cable and suitable size of conduit shall be measured as one RM.(d) Cutting chases for sub main wiring concealed PVC rigid conduit shall be deemed to be included in the quoted rate of item. 218 Supply and laying Rigid Non-metallic PVC conduit for TV socket/telephone line 25mm external dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories nuts, saddles, pipe hooks etc, complete all as specified and diercted. 219 Supply and fixing of junction boxes for TV socket/telephone line (1 to 4 way), complete all as specified and diercted. 220 Supply and fixing of TV socket/telephone socket is fitted in Robust designed assembly plates smug fit on the wall with assembly plates with suitable modules, white in colour, dust free glossy finish, complete all as specified and diercted. 221 Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 25 sqmm x 4 core, 1100 Volts grade, complete all as specified and diercted. 222 Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 16 sqmm x 2 core, 1100 Volts grade, complete all as specified and diercted. 223 Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 50 sqmm x 3.5 core, 1100 Volts grade, complete all as specified and diercted. 224 Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 Sqmm 2 Core nominal cross section in service connections complete all as specified and diercted. 225 Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5m in depth and getting out, complete all as specified and diercted. 226 Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm, complete all as specified and diercted. 227 Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and diercted. 228 Sand cushioning to under ground cables, 8cm thick layer before laying and testing the cable and 15cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I, complete all as specified and directed by Engr-in-Charge. 229 Supply and Laying Un-reinforced precast concrete cable cover class LV Type 1, flat size 250mm x 150 mm x 40 mm thick, complete all as specified and diercted. 230 Sub class B bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed. 231 Supply and fixing Single phase 240 volts Prepaid digital energy meter, complete all as specified and diercted. 232 M & L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in theground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron strip 25x4mm as earth leadby means of bolts, nuts and washers of GIup to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as specified and diercted.Notes: 1.Earth lead & protection pipes length upto & including 7.50 metre is included in the quoted rate.2.Soil should be free from stone, boulders, aggregate, gravels etc. 233 Supply and installing of the electric water storage heater (Geyser) of ABS body type of 25 litre capacity with rated power 2 KW, BEE, 5 star rated, vertical type, thermally insulated Mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostate, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm dia bore GI hexagonal adopters/Nuts on both side of inlet (cold water supply) and outlet (hot water supply) and including provision of wall mounting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation, complete all as specified and as directed by Engr-In-Charge. 234 Mild steel galvanised tubing light grade 40mm diawith all fitting; laid in trenches, across road or on pole, complete all as specified and directed. 235 Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.50m below ground level, connecting to galvanised iron wire 4.00mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.NOTE :- Item of earthing includes the cost of 7.5 m long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work. 236 Dismantling old exsting fuse unit with cover, meter unit with MCCB box and unwanted wires, removing from site, shifting of changeover switch to required location and else depositing to store all as directed by Engineer in charge 237 Supply, installation, Commissiong and Testing LT panel board outdoor type, suitable for operation on 415 Volts, AC 3 phase, 4 wire 50 Hz electric supply system, double door type, having outer body made out of 3.15 mm thick MS Sheet CRCA Sheet and inner shell made out of 2mm thick CRCA sheet of size suitable to accomodate following accessories with front and rear hinged opening doors, handle type locking arrangement,powder coated internally and externally making it dust and virmin proof conforming to IEC 61436 Part-I & II. The cubical shall have frame work of angle iron 75x75X6mm, Alumninium Bus bar of incomer switch gear duly sleeved with heat shrink sleeve colour coated for 3 Phase 4 wire electric supply system and control wiring with multistranded PVC insulated copper wire size not less than 1.5 Sqmm. Panel shall have angle iron legs of appropriate size and embedded in PCC foundation of size as required or approved by manufacturers in PCC 1:2:4 Type B-2, using 40 mm graded crushed stone aggregate. Cost of PCC foundation, earth work and following accessories shall be deemed included in quoted rates: 238 Incoming:(a) MCCB 250 Amps, 4 pole AC with rupturing cap 36 KA,LT 415 Volts, 50 Hzcomplete with adjustable thermal setting, extended rotary handle, spreader, phase barrier = 01 No(b) On/ Off/ trip Indicator : 01 Set (c) Auxillary 1 C/O + TAC 1 C/O = 01 No(d) Control MCB 6 Amp SP, 10 KA = 01 No.Outgoing: (a) MCCB having current rating 200 Amp with rupturing cap 36 KA, AC 415 Volts, 4 pole complete with adjustable thermal setting, extended rotary handle, spreader, phase barrier =02 Nos. (b) On/ Off/ trip Indicator = 03 Set. (c) Auxillary 1 C/O + TAC 1 C/O= 02 Nos(d) Control MCB 6 Amp SP, 10 KA = 02 Nos. 239 Outgoing: (a) MCCB having current rating 160 Amp with rupturing cap 36 KA, AC 415 Volts, 4 polewith with adjustable thermal setting, extended rotary handle, spreader, phase barrier = 03 Nos. (b) On/ Off/ trip Indicator = 03 Set (c) Auxillary 1 C/O + TAC 1 C/O= 03 Nos(d) Control MCB 6 Amp SP, 10 KA = 03 Nos.(e) Digital VAF + PF Meter =01 No (f) LED Phase Indicator Lamp (R, Y, B) = 01 Set of 03(g) Control MCB 2 Amp SP, 10 KA = 03 Nos(h) 3 Phase 4 wire CT operated Energy Meter LCD Type = 01 No (Duly tested by HPSEBL (Make: Secure Premier 300 Type : E3T055 IS 14697) 240 Notes:(i) Incoming and outgoing cable shall be connected to panel with proper size of metallic cable glands and thimbles.(ii) Apron shall be provided at bottom of protection of coble to avoid entry of vermin, reptiles(iii) Layout diagram of panel shall be produced by contractor for approval of GE before placing order to manufacturer and the same shall be brought to site as per approved drawing.
Contract Date: Jan 21, 2026 Contract Value : 35.83 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
Himachal Pradesh View Result →
3.
Defence #9609227 AOC
Tender For Special Repair To Building No. P-25 (Or Md Accommodation) At 28/2 Camp, Provision Of Interlocking Tiles Pathway In Dd Line And Provision Of Eight Chemical Earthingat Mil Stn Yol; 1 Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each and removing from site, complete all as specified and directed. 2 Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but not exc. 4 Sqm each and removing from site, complete all as specified and directed. 3 Pressed steel frames of size 105x60mm for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate, 25x3mm flat iron 230mm long hold fast etc, complete all as specified and directed. 4 Pressed steel frames of size 125x60mm for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate, 25x3mm flat iron 230mm long hold fast etc, complete all as specified and directed. 5 35mm thick flush shutters, solid core construction with block board core and plywood face panels commercial type on both sides, complete all as specified and directed by Engr-In-Charge. 6 Factory made 2nd class hard wood (Sal) glazed and Skelton door shutters 35mm thick open rebated and prepared to receive glass gauge etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass or gauge etc., size of members of shutter as specified in clause 8.24 (a) of part-I, fitted to chowkats, complete all as specified and directed. 7 Factory made solid PVC Door/window/ventilator Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges shall be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing on page No 180 of MES SSR 2020 Part-II, complete all as specified and directed. 8 Factory made fully glazed PVC (frosted/ground/obscured) window/ventilator shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; complete all as specified and directed.Note:- Glass gauges inclusive of quoted rates. 9 Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged, glazed skelton shutter (for glass and wire gauge)ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consiting two Nos sash bar of T-Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thickincluding cutting holes and making good dismantled portion in PCC M-15, type B-0 (04 Nos for each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces) and finishing the surfaces to match with existing including following fitting welded to frame shutter:- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf. (iii) MS tower bolt 150mm long - 2 No per leaf. (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge -1 No per leaf. (vi) Mild steel butt hinge of size 75mm x 12mm - 2 Nos per leaf. (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge. (viii) Fabrication & fixing arrangement as per drg No. CEPZ/ TD 06/07. Make : As per Appendix C. Note:-(i) Above referred drawing has not been made part of tender. The same can be seen in the office of GE during working hours on any working day. 10 M&L WPC (Wood Polymer Composit) Double Prelam Door Frame (Chowkhat) of Size 120mm x 50mm with a wall thickness of 5mm(+/- 0.25), made out of extruded 5mm(=0.25) mm thick PVC Sheet of Density 600kg/cbm manufactured y an ISO 9001-2015 certified company and by joining 3 Nos heat moulded PVC Sections. The high section of size 35 x35 mm shall be maid from plain colour PVC sheet of 5mm(=/- 0.25 mm) thickness. The inside section will be covered with 5mm thick PVC sheetC shape covering section of size 120mm x 50mm. At centretop position 5mm(+0.25mm) thick 50 x50 x50 mm pattam section should be pasted with solvent cemen adhesive to make double pattam of frame. The frame shall be mitre cut at two corners & joined with 4 nos of 150mm long L brackets of 19 x 19 mm MS square, Tube or fusion heat welding process. The two vertical door frames are to be reinforced with 25 x 25 mm MS square Tube of 19 gauge throughout the frame. The Door Frame shall be fixed to the wall using 8/100mm fischer screws. A minimum of 4 nos of screws to be provided for each vertical member & minimum 2 Nos. for horizontal member etc. complete as per manufactures specification & direction of engineer-in charge. 11 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of solid core single Leaf Flush Door of 25mm thickness, lipped with 15mm (5mm x 3) thick x 30 mm width on one stiles and top rails & 10mm (5mm x 2) thick x 30 mm width on the other stiles & bottom rails. The inner panel Laminated with 2mm thick termite proof, water proof & fire resistant moulded PVC sheet with 2,4,6 raised panel design in different plain &/or prelam colors on one side after routing the mouldd design on flush door & 2mm plain and/or prelam PVC sheet on other side using rubber based adhesive on flush door & solvent cement adhesive on the lipping etc. complete as per direction of Engineer-in-charge, manufactures specification and drawing. 12 Sheet glass 3mm thick ordinary quality and glazingwith oil putty/aluminium beads in squares, not exc. 0.5 Sqm in each pane, complete all as specified and directed. 13 Figured glass, pin head type3mm thick and glazing with oil putty in squares n exc 0.5 Sqm in each pane, complete all as specified and directed. 14 Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks of glavanised wire staple fixed with stainless steel wire staples, fixed, complete all as specified and directed. 15 Applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surfaces of any description, exc. 10cm width or girth including preparation of surfaces, complete all as specified and directed. 16 Butt hinges (ISI marked), medium weight, cold rolled, mild steel 100mm long, complete all as specified and directed. 17 Extruded aluminium alloy handles (ISI marked, fabricated type, anodised, of size 150mm, complete all as specified and directed. 18 Aluminium anodised, (ISI marked), barrel tower bolts of extruded section, length of bolt 150mm, fixed, complete all as specified and directed. 19 Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 250mm with lipping frame to match, complete all as specified and directed. 20 Ordinary rat tail rod pattern springs 300mm, including roller and roller plate complete all as specified and directed. 21 S&F for Steel locking bolts with mild steel electrogalvanised plate and bright bolt not less than 10mm dia 100mm size all as specified. 22 Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165, complete all as specified and directed. 23 2nd classhard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as as specified and directed. 24 Prelaminted particle board 18/19mm thick interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination and fixed with screws to timber frame work as on wall panelling cup boards shutters/shelves (sliding or fixed), complete all as specified and directed. 25 Extra over rates of 18/19mm thick block board or veneered particle board/ prelaminated board for external teak wood lipping, 6mm thick fixed with nails, complete all as specified and directed. 26 Continuous (piano) hinges, mild steel, bright finish or electrogalvanised Width of flaps (when open) in 40mm, complete all as specified and directed. 27 Extruded aluminium alloy handles (ISI marked), fabricated type, anodised, of size 75mm, complete all as specified and directed. 28 Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified and directed. 29 Dismantling timber scantlings 40 sqcm and over in section, any position, any description not otherwise provided for,complete all as specified and directed. 30 Dismantling boarding, any discription fixed in any postion with nails, complete all as specified and directed. 31 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish of the premisses, complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. 32 Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. 33 Non skid, Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. 34 Non skid, Premium class I grade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand), complete all as specified and directed. 35 Non skid, Premium class Igrade, coloured, ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, as in skirting, dado etc . set and jointed in neat cement slurry and includingincluding 10mm thick rendering in cement mortar (1:3) including necessary cutting as per site requirement complete all as specified and directed. including necessary cutting and waste as per site requirement pointed in white or coloured cement to match, complete all as specified and directed. 36 Glazed coloured tiles of size 450x350x7mm thick as in vertical surfaces such as jointed in neat cement slurry and pointed with coloured cement to match and including 10mm thick plastering in cement mortar 1:3 (1 cement : 3 coarse sand), complete all as specified and directed. 37 Machine cut kota stone slab flooring 18-20mm thick of size not less than 550 mm X 550mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC sub base, complete all as specified and directed. 38 Plain cement concrete M-15, nominal mix, type B-0, using 12.5mm graded mechanically crushed stone aggregate as inflooring, 25mm thick, surface finished even and rough to receive top finish or chamfering of RCC chajja with proper slope to drain off storm water, complete all as specified and directed. 39 Plain cement concrete M-10, nominal mix, type C-2, using 40mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5cm deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), complete all as specified and directed. Note:- The unit rate include for use of form work (straight or curved). 40 Demolition of cement concrete (un-reinforced) of any description and any position not otherwise specifically provided for, including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. 41 Plain cement concrete 1:5:10, nominal mix, type E-2, using 40mm graded mechanically crushed stone aggregate as in sunken floors, filling and mass concrete, complete all as specified and directed. 42 Water proofing treatment of sunken floor using SHALIURETHANE- BTD OF STP MAKE OR EQUIVALENT as approved by GE, high solid content single component water based liquid applied elastomeric water proofing membrane as ASTMC 836 and ASTMD 6083, thickness of the membrane shall be 1.5mm, having solid content of more than 80% elongation of 500+(-) 50%, laid over reinforcing layer on non woven geo-textile mesh of 40/50, 50 gms, including applying self primer coat by diluting with 1:1 ratio @ 0.4 kg per sqm and surface including 10 mm thick 1:3 plaster including cleaning of existing treatment complete all as specified and directed 43 Rendering cement plaster 10mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (5mm thick first layers and 5mm thick 2nd layer) mixed with WPC @ 3% weight of cement on fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and as directed by Engr-In-Charge. 44 Plain cement concrete M-15, nominal mix, type B-1, using 20mm graded mechanically crushed stone aggregate as in sunken floor, 25mm thick, surface finished even and fair, complete all as specified and directed. 45 Mild steel galvanized iron water tubing 32mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings as in spout of sunken floor, including taking down old pipe, complete, all as specified and directed. 46 75mm thick Plain cement concrete M-10 nominal mix, C-2, using 40mm graded mechanically crushed stone aggregate as in sub base flooring, complete all as specified and directed. 47 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. 48 Dismantling stone slabs and tiles of any description or thickness, laid bedded and pointed in any mortar in floors, aprons etc.including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. 49 Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for, including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. 50 TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. 51 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping)etc. for fair finished flat surfaces of concrete, complete all as specified and directed. 52 Marble 18 to 20mm thick, green marble, (table rubbed and polished and moulding of outer edges) as in kitchen cooking platform /shelf and verticle surfaces duly machine cut in skirting /dado and like laid over and including 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade green marble type, complete all as specified and directed. 53 Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, including formwork, complete all as specified and directed. 54 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed. 55 S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 56 S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 57 Dismantling and breaking up PVC drain pipes 75/110mm dia, fixed to walls, laid in floors or in trenches and removal of demolished materials from the site, complete all as specified and directed. 58 PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75mm, fixed, complete all as specified and directed. 59 PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors, trenches, of bore 110mm, complete all as specified and directed. 60 PVC (SWR) pipes single socketed, in any length with rubber ring joints, in floors, trenches, of bore 75mm, complete all as specified and directed. 61 PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 110mm, complete all as specified and directed. 62 PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with adjustable clamps of bore 75mm, complete all as specified and directed. 63 PVC (SWR) junction single, (Single T) equal or unequal, 75mm bore, provided with oval access door, fixed in repair, complete all as specified and directed. 64 PVC (SWR) junction single, (Single T) equal or unequal, 110mm bore, provided with oval access door, fixed in repair, complete all as specified and directed. 65 PVC (SWR) bends any radius, 110mm bore jointed with solvent cement (fitted with or without oval access door), fixed in repair, complete all as specified and directed. 66 PVC (SWR) bends any radius, 75mm bore jointed with solvent cement (fitted with or without oval access door), fixed in repair, complete all as specified and directed. 67 PVC (SWR) vent cowl 110mm bore fixed in repair, complete all as specified and directed 68 Rotational moulded polyethylene water storage tank 500 Litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including PVC float ball valve 20mm dia epoxy coated aluminium rod with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line, complete including taking down old tank and removng to store all as specified and directed. 69 Sink with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connectingunion to pipe, including 40mm dia waste pipe & CP waste coupling, overall size 915mm x 460mm bowl size 405mm x 355mm x 178 mm, Cat No Blue Star SSSB-52 Silver Shine or equivalent in makes specified in Appendix C fixed in repair complete all as specified and directed. 70 Soap dish, chromium plated, fixed to plugs with chromium plated, brass screws and fixed in repair, complete all as specified and directed. 71 Sheet glass shelf assembly 55cm long consisting of 5.50mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, selected quality as approved by GE, fixed in repair, complete all as specified and directed. 72 Chromium plated brass shower rose, fancy type (as approved by GE/Engr-In-Charge), 125mm size with shower arm, chromium plated, 195mm longh with bend of 45 degree with flange suitable for 15mm bore pipe with or without swivel joint fixed to pipe, fixed in repair, complete all as specified. 73 Angle/stop valve, cast copper alloy, fancy type chromium plated, screwed down, high pressure with crutch or butterfly handle,screwed both ends for 15mm bore iron pipe or for unions and fixed in repair, complete all as specified and directed. Make : Cat. No.360006 of Hindware orF1016201of CERA or 8110 of Prayag or TQT-526N of Essco or equivalent in makes specified in Appendix C 74 Stop valve, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed in repairs, complete all as specified and directed. Make : Cat. No.360007 of Hindware orF2014361 of CERA or 8118/8120 of Prayag or TQT-514A of Essco or equivalent in makes specified in Appendix C 75 Bib taps, fancy type 15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, chromium plated screwed for iron pipe or for brass ferrule and fixed in repairs, complete all as specified and directed.Make : Cat. No.360004 of Hindware orF2002152 of CERA or 8108 of Prayag or TQT-512 of Essco or equivalent in makes specified in Appendix C 76 Supply and fixed in repair PVC valveless, syphonic action type flushing cistern 10 litres capacity low level with inlet, ball valve, float and handlewith brackets including 32mm dia PVC long bend flush pipe 90cm long and 15mm dia PVC connection 600mm with CP brass coupling nuts and PVC washers at both ends, fixed, complete all as specified and directed. Make : Cat. No. 504 of Prayag or B1010105of CERA or equivalent in makes specified in Appendix C 77 Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, crystal white, with PVC ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate complete all as specified, fixed in repair, complete all as specified and directed. Make : Cat. No.: CABLE 3020105of CERA orECS-WHT-453 of Essco or 20004 of Hindware or 4053/4054/4056 of Prayag equivalent in makes specified in Appendix C 78 Brass Chromium Plated, Tubular towel rail, 20mm dia, D type, 60cm long between flanges, with brackets, fixed with chromium plated screws, fixed in repair, complete all as specified. 79 Wash basins, Vitreous China (corner or Flat) size 450mmx300mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with CP coupling nuts at both ends, waste pipe of polythylene of low or high density or PVC of 32mm dia, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed in repair, complete all as specified and directed. Make : Cat. No.: S2040161of CERA orECS-WHT-841 of Essco or 10055 of Hindware or 4053/4054/4056 of Prayag equivalent in makes specified in Appendix C 80 600mmx450mm bevelled edge looking mirror of selected quality with 6mm thick polished glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers fixed in repair, complete all as specified and directed. 81 Brass CP sink mixer (wall mounted) with 165mm long swivel spout, connecting legs and wall flanges screwed down for iron pipe and fixed, complete all as specified and directed. Make:Cat. No.: F1020501of CERA or equivalent in makes specified in Appendix C. 82 Chromium plated centre hole Mixer for Wash hand basin for mixing hot or cold water with 450mm braided connection pipe (without pop-up) screwed for iron pipe, complete all as specified and directed.Make:Cat. No.: F12002461 of CERA or equivalent in makes specified in Appendix C. 83 Brass CP wall Mixer for mixing hot or cold water in bath screwed for iron pipe, complete all as specified and directed.Make:Cat. No.: F12002511 of CERA or equivalent in makes specified in Appendix C. 84 Polyethlene and unplastcised PVC pipe, 32mm dia Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm all as specified and directed. 85 Taking down cement plaster on brick or stone walls, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete including removal of debris to a distance exc 1.5 km but n.exc 2 km, complete all as specified and directed. 86 Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) on internal fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. 87 Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers on fair faces of brick or stone walls finished even and smooth without using extra cement, mixed with WPC, complete all as specified and directed.Note : Supply only Water proofing compound shall be measured and paid for seperately. 88 Material and Labour for waterproofing of exterior walls, including complete removal of existing plaster including raking out joints and applying two coats of acrylic polymer modified high performance coating (Smartcare Ultra Block 2k). The treatment shall be done from ground level and providing 15mm thick cement plaster in CM 1:4 finished even and smooth all as directed. Make: ASIAN PAINTS/BERGER/NEROLAC 89 Rendering cement plaster 10mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) on ceiling surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed. 90 Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over & including 2mm thick wall care putty, complete all as specified and directed. 91 Preparation of old treated plastered surface of wall by complete removal of existing treatment and applying two coats of oil bound distemper over & including 2mm thick wall care putty, complete all as specified and directed. 92 Preparation of new plastered or unplastered surfaces of wall to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. 93 Preparation of old plastered or unplastered surfaces of wall including complete removal of existing treatment and finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and as directed. 94 Preparation of new plastered surfaces of ceiling with 2mm thick wall care putty and applying one coat of oil bound distemper, complete all as specified and directed. 95 Preparation of old treated plastered surfaces of ceiling by complete removal of existing treatment, applying 1mm thick layer of wall care putty where required and one coat of oil bound distemper, complete all as specified and directed. 96 Taking down cement plaster/decayed concrete from RCC roof projections/upward parapet walls/down facia/soffits and fins of RCC chajjas/beams/columns/balconies etc. Supply and fixing by means of nailing wire netting of galvanised wire 1.40mm dia and mesh size 20mm and brushing neat cement slury with 3.00 Kg of cement/sqm and M&L for 20mm thick cement rendering in two layers of 10mm each (top/final layer shall be rendered after final setting of under layer) in CM 1:3 on concrete surfaces including scaffolding at a height upto 7.00 mtrs ect, complete all as specified and directed. 97 Taking up or down 15mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. 98 Taking up or down 20mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. 99 Taking up or down 25 mm to 32mm bore, steel tubing and connections, including cleaning for refixing or removal from site, complete all as specified and directed. 100 Supplying and laying of CPVC pipes 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 101 Supplying and laying of CPVC pipes 32mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 102 Tank Adaptor CPVC pipes of 32mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. 103 Female Brass Threaded Adaptor (FTA/ FBTA) for CPVC pipes of 20mm dia SDR 11 & Plain CPVC SDR 11 all as specified and directed. 104 Supply only intergal water proofing compound, complete all as specified and directed. 105 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick walls, complete all as specified and directed. 106 Plain cement concrete M-15, nominal mix, B-0 using 12.5mm graded mechanically crushed stone aggregate as in lintels upto 1.50 metre clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, chamfered angles and throating, complete all as specified and directed.Note :- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately. 107 Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches, pillars, including removal of debris to a distance exc 1.5 km but n.exc 2 Km, complete all as specified and directed. 108 Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. 109 Brick work with old sizefly ash bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. 110 S&F in repair 25mm dia powder coated mild steel, chromium plated curtain rod including brackets, complete all as specified and directed. 111 Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe.290 Gde E-165, steel work, complete all as specified and directed. 112 Preparetion of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified. 113 Steel plate rack of size 600mmx750mmx250mm made of stainless steel 0.60mm thick fixed with plugs,washers and steel screws including fixed inwall with screws ands PVCsleeve of required or fixing arrangement complete all as specified 114 Preparation of old painted steel surfaces by complete removal existing treatment of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paintover existing painted surface complete all as specified and as directed. 115 Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm, fixed in repair, complete all as specified and directed. 116 Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5m in depth and getting out, complete all as specified and diercted. 117 Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and diercted. 118 Plain cement concrete M-10 nominal mix, type C-1 using 20mm graded mechanically crushed stone aggregate as in surface channel and drains, complete all as specified and directed. 119 Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm, complete all as specified and diercted. 120 Surface excavationnot exceeding 30 cms deep and averaging 15cms deep and getting out in any type of soil, complete all as specified. 121 Hardcore of broken stone or boulders of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, all as specified. 122 Demolition and breaking up drain pipes (Salt glazed stone ware, AC, RCC pipes) 150mm dia and removal of debris to a distance exc 5 km outside station boundary, complete all as specified and directed. 123 Reinforced concrete pipes, class NP2, laid and jointed complete with collars, bore of pipe 150mm (Internal dia), complete all as specified and directed. 124 Plain cement concrete 1:4:8, type D-2 nominal mix using 40mm graded aggregate as in concrete bed to drain pipes including forming cradles, packing under and haunching against the sides of pipes after they are laid and tested for dia of pipe 150mm, complete all as specified and directed.Note:- (i) The unit rate includes for use of form work.(ii) For width and depth of PCC bed - refer preamble (a) (i) (ii) on page 356 of SSR Pt-II). (iii) Haunching shall be as per MES SSR-part-I/Part-II 125 Taking down point wiring with aluminium/ copper conductor for light point, fan & socket point/ power point etc. complete including switches, sockets, holders, (batten or pendent type), ceiling rose, switch board, bell/buzzer, bell push, and making good to the disturbed surfaces of wall/ floor etc. to match with existing surfaces including white wash/ colour wash/ distempering to match with existing wall/ floor/ ceiling finishes, complete all as specified and directed. 126 Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surfaces, complete all as specified and directed. 127 M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and includingconcealed PVC conduit(ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable sizeincluding concealedMS pressed steel (Modular sunken box) terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and Modular cover plate as top cover (ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/Exhaust fan point controlled by one switch, complete all as specified and directed. Note : i)Wiring Colour code i.e. Red/Yellow/Bluefor Phase, Black for neutral and Green for earth shall be maintained.ii) Rate of cutting chases, cement plaster, white wash and making surface good as existing surface included in quoted rate.iii) Point wiring is considered for Modular Switches and sockets. Rate of Metallic Sunken box and modular sheet cover plate and other connected accessories required for modular point wiring included in quoted rate.iv) Rate of modular switch and sockets will be paid seperately under relevant item. 128 All as per serial item No 127 above, but for one 3 pin 5 Amps socket outlet on the same board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. 129 All as per serial item No 132 above, but for one 3 pin 5 Amps socket outlet on the independent board with 1.50 sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 1.50 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed. 130 All as per serial item No 127 above, but for one light point controlled by two way switches, complete all as specified and directed. 131 All as per serial item No 127 above, but for 5 pin 15 amps socket out let on independentwith 2.50 Sqmm FRLS PVC copper conductor cable and FRLS PVC insulated, unsheathed 2.50 Sqmm stranded copper conductor cable as continuous earth wire, complete all as specified and directed. 132 S & F for modular switch 6A one way, single module, complete all as specified and directed. 133 S & F for modular switch 16A one way, single module, complete all as specified and directed. 134 S & F for modular socket for 6A 2/3 pin combined, 2 module, complete all as specified and directed. 135 S & F for modular socket for 6A/16A, 5 pin combined, 2 module, complete all as specified and directed. 136 S & F for modular bell push 6A, single module, complete all as specified and directed. 137 Supply and fix modular Bell Push with indicator 6 Amps, 1 moduleincluding all As per existing make, complete all as specified and directed by Engr-in- Charge, 138 Supply and Fixing sheet metal enclosure with socket plugtop with MCB of a two pin and earth plug and a socket complete with one double pole MCB of 20 Amps rated, complete all as specified and directed. 139 S & F for modular switch 6A two way, single module, complete all as specified and directed. 140 Supply and fixing high speed stepped type electronic fan regulator 120W, 2 module, complete all as specified and directed. 141 M & L for ceiling rose 65 x 50mm three terminals, fixed, complete all as specified and directed. 142 Sheet metal enclosures factory made flush fixed for DBs when MCBs to be used, single pole and neutral (double Door powder coated), 8 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed. 143 Sheet metal enclosures factory made flush fixed for DBs when MCBs to be used, single pole and neutral (double Door powder coated), 4 way, 240 volts with 200 Amp rated bus bar, complete all as specified and directed. 144 S & F for MCB SP 6 to 40 amps 240 Volt,10 KA, B series, complete all as specified and diercted. 145 S & F for MCB SPN 32 amps 240 Volt, 10 KA, B series, complete all as specified and diercted. 146 S & F MCB, TPN,63 A capacity, 415 V, 10 KA, C series including taking down old MCB TPN, complete all as specified and directed.Note: The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs. 147 M & L for submain wiring in and including PVC conduit 1.8 mm thick, 20 mm dia with two run of PVC insulated, unsheathed multistranded copper conductor of 6 sqmm (FRLS) and one run of PVC insulated, unsheathed multistranded copper conductor 6 sqmm (green in colour) for earth continuity conductor and connected to common earth dolly with thimble etc, complete all as specified and directed. (Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM).Note: (a) Insulation test of point wiring to be carried out on completion of work.(b) Proper colour coding is to be maintained. (Ph-Red, N-Black,Earth- Green)(c) Two runs of single core cable with one run of earth cable and suitable size of conduit shall be measured as one RM.(d) Cutting chases for sub main wiring concealed PVC rigid conduit shall be deemed to be included in the quoted rate of item. 148 S&F in Replacement basic all purpose surface and wall mountedLED tube light fitting integral type 1x 10 W, 230V, completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed. 149 S&F in Replacement basic all purpose surface and wall mountedLED tube light fitting integral type 1x 20 W, 230V, completewith all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed. 150 Taking down ceiling fan/exhaust fan of 1200/300/250 mm sweep, any size/make from existing position of any height by disconnecting electrical connections and transporting to store for Inspection in presence of Engr-in-charge/JE (or rep of department) after dismentling spares parts complete all as required at site and directed by Engr - in - Charge. 151 Taking down water storage heater(Geyser) of 25/35/50 liters capacity from electric socket and disconnecting PVC connection, water supply, screwed down and transporting to store for Inspection in presence of Engr-in-charge/JE (or rep of department) after dismentling spares parts complete all as required at site and directed by Engr - in - Charge. 152 Supply and installing of the electric water storage heater (Geyser) of ABS body type of 25 litre capacity with rated power 2 KW, BEE, 5 star rated, vertical type, thermally insulated Mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostate, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm dia bore GI hexagonal adopters/Nuts on both side of inlet (cold water supply) and outlet (hot water supply) and including provision of wall mounting arrangement and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation, complete all as specified and as directed by Engr-In-Charge. 153 Supply and fixing for AC Ceiling Fan, single phase, 230 volts, 1200 mm sweep includinggrouting the ragged bolts in wall, fixing the frame on the exhaust side and connecting up with PVC insulated three core 1.50 sqmm copper cable from ceiling rose to exhaust fan, complete all as specified and diercted. 154 Supply and fixing for AC exhaust fans, Steel body, single phase, 230 volts, 250 mm sweep including grouting the ragged bolts in wall, fixing the frame on the exhaust side and connecting up with PVC insulated three core 1.50 sqmm copper cablefrom ceiling rose to exhaust fan, complete all as specified and diercted. 155 Endura Pearl 35 Watt new generation energy saving and environmental friendly long life LED Bldg security light made up of pressure die case aluminium housing with high power LED as lighting source an lens enbedded PC cover having TOP opening seperate toughted glass/verminproof driver compartment, SPDs with IP66 protenction and impact rresistancee of IK07 connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of suitable size, Make : Havells HSN Code-8537 or equivalent in Crompton/ Wipro/ Bajaj/Philips. 156 Taking down AC Meter, checking and repairing at site by repair/replacement of contacts, terminals, indicators, glass cover, plate screws, electronic cicrcuits etc and refixing in same position complete all as specified. 157 Supply & fixing wooden box suitable to accommodate 4 Nos meter boxes and TPN DB double door -01 No, size of box shall be 80 cm x80 cm x30cm with board thickness 20mm fixed on wall with suitable opening shutter duly hinged, locking arrangements with provision for mounting metered TPN box and cable incoming/outgoing for connections including painting the box, complete all as specified and directed by Engr - in - Charge. 158 Supply and laying in trenches/through pipes or bare in road crossings/paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 35 sqmm x 3.5 core, 1100 Volts grade, complete all as specified and diercted. 159 Sand cushioning to under ground cables, 8cm thick layer before laying and testing the cable and 15cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I, complete all as specified and directed by Engr-in-Charge. 160 Sub class B bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed. 161 Mild steel galvanised tubing light grade 50mm diawith all fitting; laid in trenches, across road or on pole, complete all as specified and directed. 162 Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.50m below ground level, connecting to galvanised iron wire 4.00mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.NOTE :- Item of earthing includes the cost of 7.5 m long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work. 163 Chemical Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.50m below ground level, connecting to copper eath strip of size 32x6mm (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised iron and connected to power and sensitive equipments and lightening arrestor upto 7.5m away from earth electrode, earth strip protected by provision of galvanised iron pipe light grade 40mm bore including earth work in ype of strata, PCC chamber in plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates with 80mm thick cover of reinforced cement concrete 1:2:4 reinforced with TMT steel bars 8mm dia @ 140mm c/c bothways and frame of angle iron 50x50x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape with fixingarrangement, funnel, wire mesh, galvanised iron medium grade 40mm bore watering pipe perforated at bottom including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m, all as specified and testing on completion. 164 Notes: The rate quoted is deemed to be inclusive of following:(a)Excavation & earth work for earth pit (size 1.20m x 1.20m x 4.00m)in any type of soil including filling in ramming in layers, watering & removal of surplus soil etc as directed .(b)GI tubing light grade 40mm bore dia 7.5 mtrs long for strip protection and medium grade 40mm watering pipe.(c)The chemicals viz Bentonite Clay, Graphite Powder, Copper Sulphate, Sodium Chloride and Ground Enhancement Material (like conductive cement, carbon) of brands like Marconite, FurseCEM as requied to improve soil conductivity and maintain low earth resistance over time, especially in dry or rocky soil conditions. (d)A layer of magnesium sulphate (MgSO4) at top of earthing pit but below the PCC foundation as directed. (i.e. 150 Kg in weight)(e)Earth pit of internal size 600mmx600mmx600mm, with built in PCC (1:3:6) coping 15cm above, embedded with MS angle 50x50x3mm frame work duly painted with anti -corrosive bituminous paint, with and including RCC slab 80mm thick in cement concrete (1:2:4) type B1 reinforced with TMT steel bars 8mm dia having lifting arrangement duly painted in red color and marking earth pit as directed. Name Plate ofEarth pit icluded in rated quote. 165 (f)On testing, after completion, if the earth resistance < 1.0 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obatined.(g)M&L for copper strip of any size for earthing lead connected to equipments/DBs. (Brazing will be done at earthing lead joints except terminal connection). 166 S&F Copper strip 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed. 167 S&F Air termination, single pointed, copper rod 12mm dia and 300mm long as specified and directed. 168 S&F Test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screws all as specified and directed.
Contract Date: Jan 14, 2026 Contract Value : 33.56 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
Himachal Pradesh View Result →
4.
Housing Urban and Rular Development #9468305 Technical Bid
Tender For Rates For Material/Equipment Regarding Medical Gas Pile Line System And Modular Operation Theatre For Estimate Preparation. - Rates for Material/Equipmentregarding Medical Gas Pile Line System and Modular Operation Theatre for estimate preparation. 2 Medical Gas Pipe Line (Part-A) 3 Oxygen Manifold 4 SITC of 10 + 10 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. as per specification (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 5 Certifications: ISO 13485:2016,ISO 9001:2015, CE 6 Fully Automatic Oxygen Gas Control System 7 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 8 Oxygen Flowmeter with Humidifier 9 Essentia medical gas flowmeters are designed to measure and regulate flow.These are calibrated to specific gas & flow range. Oxygen flowmeter is intended for use with various delivery system when bubble/ micro bubble humidifier is attached downstream. These flowmeters are widely used in home care, health centers, district/ general/ regional hospitals, tertiary care, emergency vehicles etc. for administration of supplemental oxygen through nasal cannula, simple face mask,partial rebreathing mask, non re-breather mask, resuscitation mask etc. A passive process to humidify dry therapeutic gas (Category 3 Humidification) Micro Bubble Humidifier for Respiratory Therapy Patient connection port : Tapered hose barb suitable for 6 mm inner diameter plastic tubingMicro bubbles through humidifier for efficient humidificationPossible to integrate into an oxygen concentrator, sleep apnoea therapy equipmentOptimal RH achievable at various flow settingsAutoclavable at 121°C (249.8°F) for 5 minutes (Minimum 5 autoclave cycles)Over pressure safety valveNon-heated and reusableInlet connection port : DISS female adapter with chrome plated Brass nut embedded in ABS for hand-tighteningFlow : Up to 15 lpm @ 4 bar (58 psi)Construction material: Polycarbonate - shatter resistantCapacity - 240ml at max water level (Jar 450ml)Make- Altos/Aktiv or Equivalent 10 Emergency Oxygen Manifold 11 The oxygen cylinder manifold should comprise of two cylinder Banks which can accommodate 6 cylinders in each Bank (means 6+6) complete with copper tail pipes with bull nose fittings of RH External threading suitable for cylinder valves (Oxygen service) and Cylinder support system. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves. High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Make- Altos/Aktivor Equivalent 12 Fully Automatic Oxygen Gas Control System 13 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 14 MEDICAL NITROUS OXIDE SYSTEM 15 Nitrous Oxide Manifold 16 SITC of 4 + 4 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders.. as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 17 Fully Automatic Nitrous Oxide Gas Control System 18 SITC of Fully Automatic Control Panel for Nitrous Oxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel. It should fully complies and meets with the requirements of the NFPA-99 standards. It should be UL or ETL Listed. The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 19 Emergency N2O System 20 SITC of 2 Cylinder Emergency Nitrous Oxide manifold with All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders using a high flow Preset Pressure Regulator as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 21 MEDICAL CARBON DIOXIDE SYSTEM 22 CARBON DIOXIDE SYSTEM 23 The CO2 cylinder manifold should comprise of two cylinder Banks which can accommodate 4 cylinders in each Bank (means 4+4) for cylinder valves conforming to IS 3234 (CO2@ service) complete with copper tail pipes with fittings. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Nitrous Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves.High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Each manifold should be provided with one terminal header and a NPT connection for the Automatic control panel. Make- Altos/Aktiv or Equivalent 24 Certifications: ISO 13485:2016,ISO 9001:2015, CE 25 Fully Automatic Carbon DioxideGas Control System 26 SITC of Fully Automatic Control Panel for Carbon dioxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel.The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Micro processor controlled switch-over is accomplished automaticallyAutomatically resets itself for next cycle when depleted bank is replenished. No manual resetting requiredDigital pressure indication for accurate readingPressure unit options: bar, psi & kg/cm Status indicatorsPressure Stabilizer for stable discharge pressure & flowVisual & Audible signalDesigned to suit CO2 for gas specific usageOptimized residual gasMake-Altos/Aktiv or Equivalent 27 Emergency CO2 System 28 The Emergency supply manifold shouldbe connected to downstream of the manifold control panel.The assemblyshould consist of 2 (two) cylinders connection supplying a manually adjusted regulator via a common header assembly. The delivery system is isolated from the main system by an isolation valve. Pressure gauges should indicate cylinder and delivery pressure & valves conforming to ISO 13485Make- Altos/Aktiv or Equivalent 29 MEDICAL VACUUM SYSTEM 30 SITC of MEDICAL VACUUM SYSTEM AS PER SPECIFICATION 31 Vacuum Pump : The arrangement should consist of 2 nos. of oil lubricated imported rotary vane vacuum pump. Each vacuum pump should have capacity of 5000 lpm with IEC Motor rating of minimum 10 HP @ 50 Hz or above. Vacuum pumps shall comprise of air cooled, oil lubricated rotary vane vacuum pumps suitable for both continuous and frequent start / stop operation at inlet vacuum vessels between 525 mm Hg and 700 mm Hg. The ultimate vacuum of pump shall be 0.1 mbar with gas ballast valve closed. The Vacuum Pump should be air cooled and oil lubricated rotary vane vacuum pumps designed for use in the field of high quality vacuum. It should be a robust construction, reliable operation, highly resilient carbon composite fiber vanes, Gas ballast valve. The pump should be having a 4 barriers system that avoids any oil leaks by doubling the 2 lip / shaft seals. Pump vanes shall be lubricated by a fully re-circulated and filtered lubricant supply. Also Pump design should include a lubricant separation system integral to the pump exhaust box consisting of no less than four stages of internally installed lubricant and smoke eliminators through which the exhaust gas stream must pass. This system shall consist of bulk separation, lubricant mist elimination, smoke elimination, synthetic lubricant baffle, and shall be capable of removing 99.9 percent of all lubricant and smoke particles from the exhaust gas stream. The unit should have extremely low vibration as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- multitech/hitachi/Anistaiwata or Equivalent 32 Vacuum Tank of 5000 liters water capacity.Make- multitech/hitachi or Equivalent 33 Bacterial Filter:Vacuum Filter (Bacteria Filter) of 100 cfm to 105 cfm – 3” Filter housing with drain flask.: It fully complies and meets with requirements of UK HTM medical standards. It should have BS 3928 sodium flame test certificate based on requirements of HTM standards.The bacteria filter should be designed for critical application involving removal of dry and wet dust, particulars, oil aerosol and water droplest, high efficiency glass fiber, fieece media from suction side of vacuum pump system. It should have efficiency of at least 99.995% when tested by sodium flame test and that should be according to BS 3928:1969. The Vacuum filtration efficiency should be in excess of 99.9999% as per HTM0201 & AS 2896 standards. The high efficiency medical grade filter element should have custom engineered filter media and deep pleat element technology provides minimal pressure loss and filtration efficiencies. It should have advanced filtration technology for Low pressure loss borosilicate glass microfiber-media and open cell reticulated foam pre-filtration layer captures particulates, bacteria and liquid aerosols reducing energy consumption and overall system costs. It should have corrosion protection Internal and external electrophoretic painting followed by a tough exterior polyester powder coating.It should have easily removable sterilisable drain flask and differential pressure monitor gauge. It should have push fit element design for quick and easy maintenance with unique push fit element design. It should have element end cap color black. It should have maximum temperature 60 degree centigrade (140 degree F). It should have element of E31140MV grade. It should have pipe size connection 1” = 105scfm and 180nm3/hr FAA. It should have pressure loss clean & dry = < 3kPa (30m/bar/0.44psig). It should have maximum working pressure 0.5barg(7psig. It should have manual drain valves and 250ml sterilisable glass drain flasks.(Maximum tolearance allowed will be only 10%).Smooth mobility.Sturdy trolley mounted on 5 castor base wheels.Operational when connected to centralized vacuum.Fast connection to the vacuum source.Various Vacuum Connector options.Controllable & Stable vacuum for procedure.Step-less vacuum regulation within the range.Gauge needle with anticlockwise movement .Vacuum trap with bacterial filter in series to protect.system networkDisposable hydrophobic filter element.Quick hassle-free replacement of bacterial filter.Switch toselect collection jar & quicksuction shut-off.Easy access to selector switch.90 degree angular interface connectors to push-fit catheters.Autoclavable Polycarbonate collection jars.Overflow prevention trap on each collection jar.Make- Tridentor Equivalent 34 Ward Vacuum Unit with Regulator, Collection Jar of 1000 ml with Bracket.Make- Altos/Aktiv or Equivalent 35 Theatre Vacuum Unit mounted on Trolley consisting of Vacuum Regulator with Gauge and 2 nos. of 4000 ml Polycarbonate.Make- Altos/Aktiv or Equivalent 36 Bacteria Filter (Plastic) for 100 ml Safety Trap before Vacuum RegulatorMake- Altos/Aktiv or Equivalent 37 COMPRESSED AIR SYSTEM 38 SITC of COMPRESSED AIR SYSTEM AS PER SPECIFICATION 39 Oil Free Scroll Air Compressor: The arrangement should consist of 2 nos.oil free scroll air compressor. It should be rated for 50 Hz, 3 Phase, 415 VAC power supply. Motor rating of each compressor should be 22 Kw & 30 Hp. Each scroll compressor should have a flow capacity of minimum 73 cfm (2070 LPM). The scroll air compressors shall be air cooled. Compressors shall be oil free scroll compressors suitable for both continuous and frequent start/stop operation having outlet pressure control range of 800 to 1000 kPa (8 to 10 bar). Each compressor shall have at least two individual scroll elements. The air quality shall be 100% oil free, certified ISO8573-1. The compressor shall have a sound insulating enclosure. Each scroll air Compressor should have an element consists of a fixed scroll shaped housing and a scroll shaped rotor. Air enters the compressor element through inlet opening. Once the air is drawn in, the orbiting scroll seals the inlet opening and forces the air into a continuously decreasing space. As scroll keeps orbiting, this process of compression is constantly repeated, resulting in discharging of oil free compressed air through outlet opening. Air is drawn through air filter and should be compressed by the compressor element of each compressor module. The compressed air is discharged via the check valve and a common air cooler. The cooling air is blown over the compressor element via a duct. A separate electric fan provides cooling air for the common air cooler. Each set of compressor modules has its own common aftercooler with an electric fan. The separator on compressors without integrated dryer has an automatic condensate outlet and a manual drain valve. The air compressors with integrated dryer, the dryer is equipped with a trap with an automatic condensate outlet and a manual drain valve. Each compressor element is protected by a sensor in the outlet pipe. The sensor is connected to the electronic regulator. Make- multitech/hitachi/Anistaiwata or Equivalent 40 Air Receiver of 5000 Liter Water Capacity (designed to withstand pressure of 10 Bar) with Auto Drain ValveMake-multitech/ hitachi or Equivalent 41 Medical Breathing Air Dryer- 375 SCFM - Medical air dryer heatless with purification modules are intended to provide a continuous supply of medical quality air conforming to the European Pharmacopoeia medicinal air monograph (ref. 1238), for respiratory use in healthcare facilities. The system shall be duplex such that the supply is maintained in single fault condition. Medical compressors shall be provided such that the specified volumetric flow is achieved without standby or backup systems running. Purification Module : The duplexed filter and dryer module shall incorporate high efficiency oil coalescing filters, heatless regenerative desiccant dryers, activated carbon filters and bacterial filters. The performance of the filters shall be according to below specifications: Oil coalescing high efficiency filter: mass efficiency of 99,92%, tested according to ISO 8573-2 & ISO 12500-1; Activated carbon filter: max remaining total oil content of 0,003 mg/m³, tested according to ISO 8573-5 & ISO12500-2;Bacterial filter: particle count efficiency of 99,98% at MPPS=0.06μm, tested according to ISO 12500-3. Dryer Purge Control : The dryer control system shall incorporate a Purge Saver Energy Management system that freezes the regeneration of the desiccant once adequate dew point is reached in the inactive tower. Only when the dewpoint level in the active tower deteriorates to an unacceptable level will the intelligent controller switch towers.Coarse coalescing filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of red color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 1 micron. It should have maximum particle size class 2 micron as per ISO 8573-1: 2010 . It should have maximum oil content 3 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68 degree F (20degree centigrade) = 0.3ppm (0.3mg/m3). It should have pressure loss clean & dry = 0.8psi (55m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). 42 Fine coalescing filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of blue color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.01ppm (0.01mg/m3). It should have pressure loss clean & dry = 1.2psi (85m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). Activated Carbon Filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of black color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.003ppm (0.003mg/m3). It should have pressure loss clean & dry = 1.7psi (115m/bar). 43 Fine Dust Filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element blue color end caps for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have pressure loss clean & dry = 1.5psi (100m/bar). Make- Trident or Equivalent 44 Pressure Reducing Station for 4 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 4 bar for medical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 4 bar stations - 5.5 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 10000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 45 Pressure Reducing Station for 7 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 7 bar for surgical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 7 bar stations - 9 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 4000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 46 SITC of Medical Gas Outlets- 47 Probes are crucial for gas specific and stable connection. These are used to connect medical gases and vacuum devices to outlets / terminal units of MGPS distribution network.Make- Altos/Altos/Aktiv or Equivalent 48 FeaturesSmooth quiet action.Safe keying configurations.Gas specific ISO 32 colour coding.Firm locking of connector / probe.Strong, positive and secure connection.Corrosion-free and material compatibility.Reliable and safe dispense of gases & vacuum.Pipe stub end flared to align drop pipe and to avoid butt joint. 49 Oxygen 50 Air-4 51 Air-7 52 N2O 53 AGSS 54 Vacuum 55 CO2 56 Certifications:ISO 13485:2016 – Medical devices,ISO 9001:2015 57 MISCELLANEOUS ITEMS 58 SITC of Common Electrical Control Panel for Compressed Air System, Vacuum System & AGSS as per requirementcomplete with plant room wiring. 59 SITC of Degreased Medical Grade Copper Pipe as per EN 13348 :2018. BSI Kite Mark certified. CE Certified. Third Party Inspection by TUV or Lloyds Registrara AsiaMake- Altos/Altos/Aktiv or Equivalent 60 Installation of piping should be carried out as per international standards with utmost cleanliness. Only pipes, fittings and valves which have been degreased as per International standards should be used . Pipe fixing clamps for upto 28mm diameter. Pipes should be non ferrous suitable for the diameter of the pipe. For the pipes of the sized above 28mm rigid metallic hanging or cemented supports to be used. 61 The main lines to the building to be taken overhead through metallic poles or through underground ductswith inspection removable slabs,All pipe joints should be made using inert gas fluxless brazing method.Alljoints should be of copper to copper and should be brazed by silver brazing filler material without flux while being brazed joints shall be continuously purged with oil free dry nitrogen to prevent the formation ofcopper oxide on the inside surface of the joint.All pipes should be installed without springing or forcing.All pipes shouldprotected against mechanical injury in a manner satisfactory to authorities havingjurisdiction. 62 Test: After erection, all the new pipes cleaned or purged with the help of dry nitrogen gas.Complete system should be tested with dry nitrogen at 2 times of working pressure for 24 hours. 63 Painting: All existing and proposed exposed pipes/should be painted with two coats of Synthetic enamel paint & color codification as per international standards.All concealed pipes to have gas identification bands / labels at appropriate distance.Similarly all pipes which need embedding in the wall should be tested/painted/labeled and properly insulated. 64 Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS: EN 13348. 65 All copper pipes will beUL certified for medical use before dispatch and the pipe will be delivered plugged or capped at both ends. 66 108 mm OD X 1.5 mm thick 67 76 mm OD x 1.5 mm thick 68 54 mm OD x 1.2 mm thick 69 42 mm OD x 1.2 mm thick 70 35mm OD x 1.2mm thick 71 28 mm OD x 1 mm thick 72 22 mm OD x 1 mm thick 73 15 mm OD x 1 mm thick 74 12 mm OD x 0.7 mm thick 75 SITC of Medical Gas Digital Area Alarm System 76 Microprocessor based digital LCD alarmHighly visible 7 (178 mm) LCD screenPressure sensing through piezoresistive sensing technologyAlarms can be monitored audio-visualTouch screen operationComprehensive monitoring of all the medical gas alarm panelsData display at a central monitoring station Features-Alarm status will be visible through ethernet port on master alarmPressure Equipment Directive 2014/68/EUDigital Flow Care Alarm Management of Medical Gas Pipeline SystemReal time updating of statusOperational parameters i.e. high and low level canbe set “in-situ” to suit requirement in an area 2Programmable pressure unit display (bar, kg/cm & mmHg)Audio mute optionDesigned to serve 2, 3, 4, 5 & 6 gases including VacuumNIST connection for Gas inputPowered by 220V AC to 24V DC external adapterMake-Altos/Aktivor Equivalent 77 Conforms to: IS / ISO 7396 - 1 : 2016 + A1 : 2017HTM 02-01 Part A, IS / ISO IEC 60601 - 1 : 2015 + A1 : 2020Certifications:ISO 13485:2016 – Medical devices – Quality Management SystemsISO 9001:2015 - Quality Management Systems 78 6 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar, Vacuum & CO2) 79 5 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar & Vacuum) 80 4 - Gas (O2, N2O, Med Air-4 Bar & Vacuum) 81 3 - Gas (O2, Med Air-4 Bar & Vacuum) 82 2 - Gas (O2 & Vacuum) 83 SITC Of Area Valve Service Unit with Valve & Gauge 84 The importance of full bore ball valves is to reduce pressure drop to almost negligible in the pipeline distribution system so that the designed pressure is available at the outlet point. Ball Valves are used to start or stop a flow. In Medical Gas Pipeline System (MGPS), the valves are normally kept open i.e. allow the gas to flow unless it is required to shut-off the gas supply for scheduled maintenance or emergency situation 85 Features-Operational parameters can be set in-situDigital pressure unit display options -psi / bar or kg/cmDigital & illuminated LED display of “Normal”, “High” & “Low”Microprocessor based moduleHighly accurate “Heavy Duty” pressure transducerPowder coated aesthetically designed enclosureEnclosure separable from the base for ease of installationReusable lock assemblyAudio mute optionPED: 2014/68/EU certified full port Ball Valve (PN 30)Long extension copper pipes to connect MGPS networkFront door opens up vertically for comfortable accessDesigned to serve 2, 3, 4 & 5 gas moduleSuitable for all medical Gases & VacuumMake- Altos/Aktiv or Equivalent 86 6 Gas Service (O2, N2O, Med Air-4 Bar,Air-7 Bar, Vacuum & CO2) 87 5 Gas Service(O2, N2O, Med Air-4 Bar, Air-7 Bar & Vacuum) 88 4 Gas Service(O2, N2O, Med Air-4 Bar & Vacuum) 89 3 Gas Service (O2, Med Air-4 Bar & Vacuum) 90 2 Gas Service(O2 & Vacuum) 91 SITC of Degreased Medical Lockable Ball Valve with Pipe line assembly 92 Pre piped single port) for size upto 2 (for 54mm copper pipe): Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design. It shouldbe blow-out proof stem. It should be lockable valve. The Valve shall be 3 piece ball-type design with a bronze body and chrome plated brass ball for sizes 1/2” to 4”. Seats shall be Teflon (TFE) and seals Viton for 1/2” - 4” valves. A blow-out proof stem shall be used and the valve shall have a maximum pressure rating of 600 psi [4,137 kPa].Valves shall be operated by a lever-type handle requiring only a quarter turn from a fully open position to a fully closed position. Valves shall be designed in such a manner that it can be “swung-out” during installation so as to prevent damage due to heat transfer during the brazing operation. Each valve assembly shall be washed and degreased for medical gas service. The valve shall be supplied in a sealed plastic bag to prevent contamination prior to installation.Make- Altos/Aktiv or Equivalent 93 12mm 94 15 mm 95 22 mm 96 28 mm 97 35mm 98 42 mm 99 54 mm 100 108mm 101 SITC of Bed Head Panel aluminum powder coated with mininum 3 channel and 3 duct with separate partition rows and built in aluminum railMake- Altos/Aktiv or Equivalent 102 Bedhead panel for Low Equity Ward Areas, 1500mm length, with provision of Gas outlets & provided with electrical sockets & accessories complete 103 Horizontal Bed Head Panel – For 2 Gas Service (Oxygen & Vacuum) 104 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, Med Air-4 Bar & Vacuum) 105 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, N2O & Vacuum) 106 Horizontal Bed Head Panel – For 4 Gas Service (Oxygen, N2O, Med Air-4 Bar & Vacuum) 107 Special FeaturesInnovative design – Efficient, simple & accessibleVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outlet 108 Application AreasInnovative design – Efficient, simple & accessiblityVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outletAdult in-patient wards/ General WardsResuscitation RoomsPost-anaesthesia areaEmergency Admission WardsDialysis Stations 109 Configuration : 5 Outlets & 6 Multi Standard 220V AC sockets, 1 each RJ11 Telephone socket & RJ45 Data Socket and provision of protective earth (Earthing) 110 Modular Operation Theatre (Part-B) 111 WALL AND CEILING MODULAR PUF PANEL 112 The panels shall be made of durable and uniform material that shall be easy to clean and extremely hygienic. Operation theatre shall not have any sharp edges, corners and shall not support bacteriological or fungicidal growth and shall be resistant to most chemicals, commonly used in Hospital Departments. Joints in the panels in the operation theatre shall be sealed. The function of sealing shall assure an airtight environment in the room and eliminate services to prevent dust accumulation.PUF Panel with an overall thickness of 50 mm for wall and 30 mm for ceiling, made of 0.8mm (make-Tata/jindal)GI Front sheet and 0.6mm PPGI back wall with infill of PUF at 40 kg/m3 (40D)which is necessary for mechanical strength. Panels shall be mounted on a structure made of galvanized steel and shall enable the distribution of medical gases, electricity, sewerage inside the wall.PUF Panel as above has better thermal efficiency and thus saving on energy cost. Proposed system shall be installed at site without any welding.The partitions shall not have corners; adjacent surfaces shall be molded flush.Upper wall element shall have sufficient height to reach the lower edge of the prefabricated ceiling. All the sharp edges and corners should be chamfered to avoid bacterial contamination.The individual ceiling panels shall use the tongue and groove technology for joining two panels, no welding shall be allowed,provides a seamless sub-structure, which is then sanded smooth finished with Metal Putty and then painted using imported anti-fungal paint to give a smooth, non-porous seamless finish and without corners by providing coving on floor as per standard.It is resistant to chemicals used in Operation Room for moping and fumigation repeatedly.Make-Jindal/Tata or Equivalent 113 WALL AND CEILING MODULAR PUF PANEL-SS304 114 The prefabricated Operating Room should be of SS Sandwich as per its latest standards. SS Sandwich : It should have at least min. 0.8 mm 304 Grade Stainless Steel on front side and 0.5mm PPGI back side . The sandwich panel shall have a core consisting of rigid polyurethane foam, injected under high pressure, with a minimum density of 40 kg/m3. Cladding structure insulated stainless steel wall panels with total panel thickness 50 mm for wall and 30mm for ceiling.The individual wall panels shall use tha tongue and groove technology for joining two panels, no welding should be allowed. The gaps between panels shall be suitably filled with metal filler and sanded flush. Stainless steel plate finished to fine grain surface, treated properly to take antifungal paint panelingshould be easy to maintain, durable, antistatic / conductive and fire retardant. Clearance between inner panel and outer wall should be sufficient to allow the maintenance personnelfor service. This closed space should be flushed continuously to eliminate dust and bacterial accumulation.It should have minimum number of junctions. The junction should be seamless and should be sealed with suitable sealants. Third party test certificate for SS from material testing lab. (Govt. authorized)required.Make-Jindal/Tata or Equivalent 115 ANTI-FUNGAL PAINTING 116 Anti microbial Paint for Different Areas antibacterial Paint on wall and ceiling panels Inside OT work.Anti-Microbial Protection: These product hygiene coatings start the biocidal action as soon as the microorganism land on the surface, and prevents the growth of mould, bacteria and yeasts for at least 5 years.Minimum three coats of Anti Fungal/Bacterial Paint, glaze or equivalent to a minimum dry thickness of 300 microns to give smooth , non-porous finish without any corners.It will also be resistant to the chemicals used in Operation Room for Moping & Fumigation repeatedly. This Hygiene coating are independently tested by leading universities to demonstrate resistance.Make-SKK/ Jotun or Equivalent 117 PLENUM LAMINAR AIR-FLOW 118 Supply and installation of Plenum LAMINAR FLOW- Plenum Box Ceiling mounted systemwith unidirectional airflow, SPECIFICATIONS-PLENUM UNIT - The complete unit factory designed and manufactured with proper air-sealing. It seamlessly integrates with OT ceiling mounted equipment.Plenum size- 2400 x 2400mm with aluminium material.Diffusers are made of SS304 punched/perforated sheet for unidirectional diffusion air. The complete unit factory designed and manufactured with proper air-sealing.It seamlessly integrates with OT ceiling mounted equipment.The material used is non-corossive as per standard guidelines such as Aluminium.Make-Jindal/Tata or Equivalent 119 Hepa Filters- 120 The filter hosing on either side houses provided with HEPA minipleate H13/H14 filters.The system has a reliable filter efficiency, filters are designed to remove particles and germs with the use of H13/H14 filters retaining 99.97 % of the particles and germs.Frame : Aluminium Mini Pleat Size- 610x610x125mmMOC of the Media : Micro Fibre Glass micro drawn grid Separators : continuous Gasket: Food GradeMPPS average efficiency: > 99.95% 3 Micron D Efficiency: 99.97% down to 0.3µ.Maximum Operating Temp : 60 degree CelsiusMake- Thermadyne or Equivalent 121 ANTI-STATIC VINYL FLOORING: 122 SupplyandinstallationofImportedVinylFloor:SeamlessantistaticconductiveESDvinylflooringsystem,2mmthick, with perfectly curved flush covings and copper strips for earthing, all joints welded properly including wall scatting.SPECIFICATIONS:- Flooringinoperationtheaterroomwii beseamless withperfectly curvedflash-covings,resistance tomechanicalstressanddynamicloadsandhavingESD/EMI(Conductive)protectioncharacteristics,2mmthick, washablevinyl.Flooring is a static-conductive,flexible homogeneousvinyl floor covering withan electricalresistance of 5x10^4 123 SELF LEVELLING MATERIAL. 124 The SLC should be of Portland cement-based, It should be self-leveling underlayment formulated with a special blend of polymersusedtolevelandsmoothinteriorconcrete,terrazzo,ceramicandquarrytile,epoxycoatingsystems,metal andnon-watersolubleadhesiveresidueonconcretepriortotheinstallationoffinishedflooring–on,aboveorbelow grade.TheSLCshouldprovideadurable,flat,smoothfloor surfacewithminimumlabor andinstallationtime.Itshould be pourable or pump-able when mixed with water and should seek its own level to produce a smooth, flat, hard surface. 125 OPERATION THEATRE CONTROL PANEL: 126 Supply and installation of Membrane type 6 services OT control panel , with distribution box mounted flush in the theatre wall, comprising of the following:The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations.The room Surgeon’s control panel should be modifiable with changing technology& equipment in operating environments. Control Panel will be user friendly & ease of operating & maintaining purpose.he panel should be “Membrane” type; configured to incorporate all the services that operation room staff required. The fascia should be made with superior quality UV resistance membrane with sterilization feature.The Panel should contain 6 or 9 service tiles as below:1. Time Day Clock. 2. Time Elapse Day Clock. 3. General Lighting System.4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller.7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clocks having high brightness characters.Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digitaltype & clocks having high brightness characters, not less than 30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. system inside the theatre.The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures.A hand free set Telephone System should be incorporated in the panel with memory type card.The control panel should be designed for front- access only. All internal wires should beMake- Altos/DGline or Equivalent 127 Distribution Board outside OT 128 Electrical Distribution Board will have all high voltage equipment should be installed in a separate enclosure. The remote cabinet should house the operating transformers, light control relays, electrical distribution equipment and circuit protection equipment for all circuits withinthe operating theatre. All internal wiring should terminate in connectors with screw mounted, on a DIN rail. Individual miniature circuit breakers will protect all internal circuits. All high voltage equipment should be installed in a separate enclosure.All internal wiring should terminate in connectors with screw & clamp springConnections of the clip- on type mounted, on a CE/ / ICMED9001/ ICMED13485 approved rail & labeled with indelible proprietary labels.Individual fuses or miniature circuit breakers should protect all internal circuits. 129 LED PERIPHERAL/GENERAL LIGHTS: 130 Recess mounted sealed IP54 Protocol, non-hygroscopic peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED, with optical anti- glare system for individually adjustable light distribution.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated steel frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Control equipment for the general lighting and the light dimming should be provided in the theatre Control Panel.Make-Altos/DGline or Equivalent 131 LED X-RAY VIEW PANEL: 132 TwoPlateX-RayViewScreenwithflickerfreeilluminationhavingimportedLEDsystemforuniformilluminationand operated by X-ray film .Thesystemhavingelectricalsafetycodesforhigh&Lowvoltagesystem.Itshouldbedesignedtoprovideflickerfree luminance for the film viewing purpose.It should be installed flushed with the theatre wall for hygiene and ease of cleaning.Make-Altos/DGline or Equivalent 133 MAGNETIC LISTING WRITING BOARD: 134 MagneticWritingBoard of size940x 640x50mmcomprisesof aflushmounted,1.50mmthick,whitelaminate board, bonded toa 10 mm high density fibreboard sheet for additional rigidity.The writing unit should comprise of flush mounted white laminate board, be opened to create a wall mounted writing surface within the operating room. The white board should be constructed from white laminate board.Make- Altos/Dgline or Equivalent 135 AUTOMATIC HERMETICALLY SEALING SLIDING DOOR -1500mmX2100mm 136 Automaticoperated Hermettically Slidingdoor with High Pressure Laminate on both side, Door size (1500mm wide2100mmheight)completewithdoubletoughnedglassvisionwindowof300mmx300mm withinanaluminum extrusionhighqualityframecompletewithrequiredaccessories.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings that are adjustable during installation to ensure sealing.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door HandleMake-Metaflex/Doormedor Equivalent 137 HERMETICALLY SEALING HING DOOR-900mmX2100mm 138 Manually operated Hermettically Semi- sealed Hing door with HighPressure Laminateon bothside, Door size (900mm wide x 2100mm height) complete with double toughned glass vision window of300mm x300mm andsmooth effortless doorcompletewithrequiredaccessories,fixedfirmlytothewall.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be hinge mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door Handle. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Nylon runner guides are fixed to the floor in such a way that they do not obstruct trolley movement through the door.Make-Metaflex/Doormed or Equivalent 139 CORNER GRILLS 140 Aluminium corner grills are used to air exhaust at all four corners.size of grill will be 600mmX400mm.Duly powder coated extruded aluminium linear horizontalfixed bar with normal 15 deg. blade having pitch of 13 mm.Exhaust Gril for return air-The exhaust air cabinets should be openable and cleanable. These cabinets should have suction from bottom.Distribution of exhaust air volume should be divided between fluff strainers to maintain the required pressure within the theatre without causing turbulence.The Exhaust air cabinet should be manufactured and supplied by the supplier of wall and ceiling system supplies. Also it should match perfectly with the ceiling system aesthetically.Make-conair/Bala ji engineering or Equivalent 141 ALUMINIUM DUCTING: 142 Aluminium Ducting ( 22 gauge ) with curves & bends where indicated for easy flow of air tight by applying silicon sealant after fabrication.Hangers will be provided to ducts & will be suspended be means of G.I. coated rod & these will not be more than 2.5 mtrs apart.Thermal insulation with 9/13mm XPE with aluminium foil for supply & return air ducts.Joints will be lapped with Nitrile tape for better insulation. (Laminar to AHU & Return air in all four corners) AHU to be placed near OT, not more than 6 meter.SITC OF Hand fabricated rectangular Aluminum Ducting in accordance with the approved ducting lay out drawing, complete with all accessories , dampers, guide, vanes, support, etc.Make-Hindalco/Virgo or Equivalent 143 AIR HANDLING UNIT 144 AHU System & Condensing Unit with consistingDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GI Frame Work Hollow Extruded AL Profile Thickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material ofDrain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base Channel DX COIL: Make Of Coil ZECO Coil Casing / Blank offs GI Material Of Tube Copper (IGT) Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material Copper Thickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12 FILTERS: Media of Filters Synthetic (non woven type) Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron FAN & MOTOR: Fan make Nicotra Motor make CG Motor type TEFC Squirrel Cage IP 55 Protected VFD Compatible induction motor VFD: VFD make DELTA DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE:(WITH 25MM THICK PANEL) ◻ Mixing box with manually operated FA & RA damper in GI constructionDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GIFrame Work Hollow Extruded AL ProfileThickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material of Drain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base ChannelDX COIL: Dx type coils having suitable number of distributors for connecting expansion valve with condensing unitsMake-Zeco//VTS or Equivalent 145 Make Of Coil Casing / Blank offs GI Material Of Tube Copper (IGT)Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material CopperThickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12FILTERS: Media of Filters Synthetic (non woven type)Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron VFD: DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE: (WITH 25MM THICK PANEL)Mixing box with manually operated FA & RA damper in GI constructions.Filter section with 50 mm thick (EU-4) box type pre filter with 305 mm thick (EU-5) bag type fine filter mounted on common filter frameCoil section with 6 row deep DX cooling coil with suitable distributor. Heater Section with GI strip Heater.Fan section with SISWbackward curved plug fan & Motor (IE-2). Manually operated SA damper in GI construction.Tonnage TR 8.5 Air Qty (CFM) 3500SP (mm wg) 125 UnitFan Type Plug Fan-355Fan model RLC E6-3135-23-19 Fan RPM 3400Motor RPM 2880Shaft Absorbing Power 3.2 Motor Rating (kw) 3.7 Motor pole 2Coil area (Sq.Ft.) 7.0 DX Cooling Coil RD 6 Distributor 1Heater KW3Filter area (Sq.Ft.) 8.0 Length (mm) 2500Width (mm) 1400 Height (mm) 945 146 AIRCONDITIONING: (8.5 T AC ) 147 Nominal Cooling Capacity-8.5tr,102000Btu/hr,29894watt Nominal Air Quantity-6250CFMPower Supply (V-ph-Hz)-400 ± 10% -3-5 Fan-PropellerDischarge-HorizontalFan Motor-Permanent Split Capacitor Type Power (watt)-470Control Type-LED DisplayOverall dimensions (mm)-982 X 610 X 1100 mm- Compressor- Scroll CompressorRefrigerant-R-410A (5.6) Liquid Line-5/8Suction Line-1-1/8Make- Carrier or Equivalent 148 ELECTRICAL WIRING INSIDE THE OT 149 Electrical Wiring as per requirement of OT, Wiring With OT distribution electrical Panel. ( Power cable at OT with Main distribution Panel will be provided by customer) Operation theatre shall be installed in the remote cabinet.All electrical wiring should be terminated to the connectors mounted on DIN/CE approved rail and labeled with indelible labels.Individual fuse and miniature circuit breakers should protect all internal circuits.Complete schematic diagram drawing description should be enclosed with the equipment. Makes:Scheinder/PolyCab/ Schematic.Supply, Installation, Testing and Commisnoing of Electrical Distribution Board with required MCB : It should be installed in a separate enclosure.Transformers,Mains,Relays,Circuitprotectiveequipment,forallcircuitsofOperationtheatreshallbeinstalledinthe remote cabinet. 150 MEDICAL GAS PIPE-LINE SYSTEM INSIDE OT 151 Medical Gas Pipe Line inside the OT above ceiling as required, complete with valve box and other required fitings. Medical Gas copper pipeline inside the OT and the Provision to connect to Pendant Systems (inside OT only).It should be confirm and meets with BS:EN:13348:2008 copper pipes.All medical grade degreased copper pipes must be inspected and duly Third Party Certified by Lloyd’s Registered Asia. Medical Grade Copper pipes manufactured from Phosphorous de-oxidized non-arsenical copper to BS:EN: 1412:1996 grade CW024A (Cu-DHP) manufactured to metric outside diameters and having mechanical properties in accordance with BS:EN: 13348:2008 & 250 or 290 (Half hard).Degreasing of pipe shall be such that there is less than 20 mg/m2(0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS:EN:13348:2008.Make- Altos/Aktiv/Mandev tubes/Mehta tubes or Equivalent 152 PASS BOX SIZE-2FTX2FTX2FT 153 Pass Box to remove the waste materials from the Operation Room to the Dirty Linen Area. Each box is equipped with two doors and the door should be operated electronically.. It is designed in such a way that only one door can be opened at one time. UV light is so installed that it is kept on while both the doors are closed and turned off automatically when the doors are opened. Indicators on both side of the Operation Room for Door Open/Close status. It is made of SS-304 Grade.Make- Jindal/Tata or Equivalent 154 STORAGE UNIT 155 Storage Unit of size 850x1600x350 mm has made of 1.6mm galvanised steel sheet. The exterior glass doors has lockable with magnetic push-button for easy opening. Removable toughened glass shelves of thickness 5 mm will be provided with the storage units.Make- Jindal/Tata or Equivalent 156 Pressure Relief Dampers 157 Pressure relief dampers should be provided in each room to prevent contamination of air from clean and dirty areas. Suitably sized air pressure relief damper should be strategically placed, enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty areasCounter- weight balancing system should be provided in the PRD to maintain positive pressure inside the operation room.Air pressure stabilizers should have unique capability of controlling differential pressure to close tolerance.The PRD should remain closed at pressure below the set pressure and should open fully at a pressure only fractionally above the threshold pressure.The body of PRD sleeve and Grill should be epoxy powder coated as per standard High grade SS304 Stainless steel plate should be used for body and for bladesMake- Jindal/Tata or Equivalent 158 OT Pendant –Single Arm Anesthesia(Modular) 159 Anesthesia Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.Make- Altos/Aktiv or Equivalent 160 The Pendant Service Heads / column should be supplied with medical gas terminal units. The medicalgas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard. 161 Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 2 no, Air (4 Bar) – 2 no, Vac – 2 nos, AGSS – 1 no. Medical rail with brake buttons fitted. - 1 No.Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its lengt 162 OT Pendant -SURGICAL PENDANT : 163 Surgon Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.The Pendant Service Heads / column should be supplied with medical gas terminal units. The medical gas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard.Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 1 no, Air (4 Bar) – 1 no, Vac – 2 nos.Medical rail with brake buttons fitted. - 1 No.Make- Altos/Aktiv or Equivalent 164 Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its length. 165 UV LIGHT INSDIE OT FOR CLEAN/STERILIZE PERPOSE SIZE-2FTX1FT 166 Recess mounted sealed IP54 Protocol, non-hygroscopic UV peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED. Ultraviolet (UV) lamps are commonly used in operation theatres for disinfection.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Make- Altos/Dgline or Equivalent 167 Surgical Scrub Station – Two Bay 168 Compact surgical scrub sink should be designed for use in OT complex providing for pre – OT scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel and should be seamless welded construction, polished to a satin finish.The washing faucet shall be made of Chrome plated brass hand. The station shall be equipped with soap dispensers made of SS 304 grade.The scrub sink should be provided with a front access panel which should be easily removed for access to the water controlled value, waste connections, stoppers and strainers.Hands free operation should include infra red sensors with built-in range of adjustment.The scrub station shall be made of high-grade stainless steel 304 with stain polish finish and wired to the current IEE regulations & BS 7971.Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature. User defined setting of 1,3,6 & 10 min should be available. This timing should be adjustable to meet individual application requirements.All units should have reduced anti- splash fronts.The scrub stations control system shall be based on advanced microprocessorThe scrub station shall be sensor-activated 24VAC and should have the provision to operate it manually in case of power failure by using foot switch or knee switchimported thermostatic mixing valve for Hot & Cold water, Strainers, Spouts & manual foot operated valve system.Make- Jindal/Tata or Equivalent 169 AUTOMATIC PHASE SEQUENCE CONTROLLER 170 PMC Based (Pre magnetic Contractor)63A Double interlock & time Delay systemAuto/Manual Operation Sie- 140 x 275 x 320 mm Smooth and fasr Switchingworks well even at high & low voltages. Wide Current rnge.Voltage Range-130-280Vac Temperature- 55 Degree Celsius Auto mode Selector switchDigital micro Control relay for sequence management.LED Indicator for complete status of power.Make- Subtech or Equivalent 171 Operation Theatre Light - LED type, Camera Ready (Triple Arm) 172 Operating Room Surgical Lighting system should provde an ideal combination of broghtness, maneuverability, and shadow resolution without sacrificing color accuracy throuh a consistent LED technology. Such Lighting System should have the following technical specifications: 173 a. Number of light heads : Two per suspensionb. Colour Temperature range : 3800k-5000 (±10%) - Variable color temperature. c. Field Size Diameter : 20 to 28 cm (+/- 10%)d. Working range : 750 to 11100 mm (+/- 10 %)e. Illumination Level : 160000Lux (major Dome & Minor dome )f. Rotation : 360 - 330 degree g. Sterilizable Handle : 02 Nos h. Mounting type : Ceiling i. Supply Voltage : 230 VAC 50 Hz j. Bulb Type : LEDk. Dimming Range : 50% - 100%l. Operating / Storage Humidity : 10 - 95 %m. Life of Light source : > 40,000 Hrs n. Should be provision to mount the camera in 1 dome . o. Surgical Light System Should be compliant with relevant European CE / US FDA standardsMake- HillRom/Steris orEquivalent 174 GST Extra as applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
5.
Defence #8538912 AOC
Tender For Special Repair To Building No A/4/133 At Pms (2Nd Call).; 1 Dismantling floor hearth or wall tilling including cement mortar bedding, removing rubbish off the premises complete all as specified and directed. 2 Demolition of cement concrete (un-reinforced) not exceeding 15 cm thickness of any description and in any position not otherwise specifically provided for all as specified and directed. 3 M&L for 100 mm thick PCC 1:2:4, type B1, (using 20 mm graded crushed stone) , as in sub base for receiving floor finish with nominal reinforcement complete all as specified and directed.Reinforcement will be measured and paid seperately. 4 M&L Non Skid ceramic colouredtiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm in floors etc , over & including 15 mm thick cement mortar (1:6) screed etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and directed. 5 M&L for glazed ceramic colour joint free tiles tiles in verticle surface 350x450x7mm thick set and jointed in neat cement slurry over 10 mm thick 1:4 cement mortar plaster and pointed in coloured cement to match complete all as specified and directed. 6 M&L for fly ash brickstraight or curved on plan exc 6 mtr mean redious built in CM 1:6 ,including demolition of brick work built in cement mortar including all quoins, arches, pillar etc all as specified and directed. 7 M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. 8 M & L for TMT bars6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers and binders complete all as specified and directed. 9 Taking down cement plaster, any description on brick or stone walls and ceiling ,chajja, landing etc including racking of joints hacking for key scrubbing down with water etc complete all as specified. 10 M&L for Rendering 15 mm thick in Cement Mortar 1:4 finishing fair and even t with approved water proofing compound as per manufacturing instraction over and includingtwo coat ofwater proofing coating latex-based, water-resistant multipurpose admixture in the ratio of SBR latex : Water : Cement = 1 : 3 : 8 oras per manufacturing instructions complete all as specified and as directed. (Note:- WPC will be measured and paid separately) 11 Supply only integral water proofing compound, complete all as specified and directed. 12 M&L Rendering 15 mm thickon other than fair faces of brick work or concrete surfaces, finished fair and even on walls in cement mortar (1:6), complete all as specified and directed. 13 M&L Rendering 5 mm thickon fair faces of concrete surfaces, finished fair and even on ceiling/chajja/pillar in cement mortar (1:3), complete all as specified. complete all as specified and directed. 14 Material & Labour for preparation of new surfaces of plastered walls and applying Twocoats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. over and includinga coat of primerover plastered surfaces of walls to prepare the surface even and smooth complete all as specified. 15 M & L for applyingthree coat of white wash on ceillingnewsurface ofcomplete all as directed by Engineer in Charge. 16 M&L for treatment of wall &applying twocoats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004 , alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives@ 1.43 litre/10sqm over and including priming coat of alkali and fungal resistance exterior primer applied @ 0.90 litre/10 sqm including a coat of putty 1 mm thick plastered surface to prepare the surface even and smooth for smooth finish over new surfaces complete all as directed by Engineer in Charge. 17 Taking down chowkhats or frame not exceeding 1.5 Sq. m each with shutter(s) (without taking off shutters from the frame), complete all as specified and directed. 18 Taking down chowkhats or frame exceeding 1.5 Sq. m but not exceeding 4 Sq. m each with shutter(s) (without taking off shutters from the frame), complete all as specified. 19 S&F Powder coated aluminium (miimum thickness of powder coating 50 micron) work for doors, windows, ventilators frame and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling upthe gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per thedirections of Engineer-in-Charge 20 S&FPowder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-chargeher for openable/sliding shuttters) including all necessary fittings as directed 21 M & L for Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads all as specified and as directed. 22 S&F Sheet glass 4.8 mm thick, ordinary quality & glazing with oil putty in square but n.exc 0.5 sq.m in each pane complete all as specified and as directed. 23 S&F Sheet glass 4.8 mm thick, ordinary quality & glazing with oil putty in square but exc 0.5 sq.m in each pane complete all as specified and as directed. 24 S&F brass 4-levers mortice lock, vertical type , size 100mm complete all as spcified and as directed. 25 S&F in repair Aluminium (extruded section) body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg complete all as specified and as directed. 26 S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 27 M & L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ howkhat of size 50x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction ofEngineer-in-Charge. 28 S & F 35mm thick Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size c mprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) 29 Dismantling of timberfillets rails, posts, rafters, purlins etc under 40 Sq cm in section complete all as specified and directed. 30 S & F roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe-410-W (Gde-E-250) quality-A complete all as specified and directed. 31 M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on newly steel surfaces of any description over 10cm in width or girth not otherwise described incl preparation of surfaces complete all as specified and directed. 32 Dismantling of Asbestos cement (Corrugated, semi corrugated, etc.) sheet in roof covering Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof in roof coverings complete all as specified and directed. 33 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measurescomplete all as specified and directed 34 M & L forpre-paintedhot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specifiedany heightMtr height including all necessary scaffolding and safety measurescomplete all as specified and directed 35 Dismantling of wall or ceiling borads of any thickness including cover fillet complete all as specified and as directed. 36 S&F for 6 mm thick non asbestos fibrecement designer buildingboardsfixed or laid/ inserted to timber/GI / Aluminium frame work with screw fixed in ceiling flat or sloping including hangers 4 mm dia GI (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long including anodised aluminium snap grid 605 x 605 mm frame work complete all as specified. 37 M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fairlaid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand complete all as specified. 38 M&L for PCC 1:3:6 type C1 using 20mm garded stone aggregate as in surface channel all as specified and directed. 39 M&L for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. 40 M&L for repair to crack portion with jacktting technuque, taking down existing plaster up to brick wall surface of min 200 mm wide, cleaning to loose particles on surface of brick work along the length of crack and filling the gap/crack area with PCC 1:1.5:3 type A0 using 12.5 mm aggregate up to brick surface and inserting the welded mesh of size 25 x 25x 2 mm dia along the crack on both side of the wall surface fixed with, drilling holes 10 mm dia on either side of the crack by means of drilling machine through out the full width of the wall @ 25 cm c/c and insert 8/10 mm dia rod in the drilled holes, welded with horizontal rod to with hold the welded mesh and applying grit plaster 1:1:2 using 4 mm and down aggregate finished even and smooth without using extra cement complete all as specified and directed.(Note: Reinforcement and welded mesh will be measured and paid separately) 41 E/M PORTIONTaking down carefully aluminium/copper conductor point wiring (light , fan, call bell, socket or power) complete including fittings such as switches, ceiling rose, pendents, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) and making good disturbed surfaces of walls, floors etc to match with the existing complete all as specified and directed. 42 M & L for concealed point wiring for fan/light point controlled by one one way switchcomplete with 1.5 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including PVC FRLSH insulated 1.5 sq mm copper conductor for earth continuity (Green Colour)and connected to common earth dollyincluding sunken in GI terminal box2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets ect.Note : a) Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surfaceare deemed to be included in the quoted rate. 43 All as per item No. 42.00 here-in-before but5 Amp socket on same boardwith other switches. 44 All as per item No.42.00 here-in-before but 1.5 Sqmm copper conductor & cable for5 Amp socket on Independent boardwith other switches. 45 All as per item No 42.00 above but using 2.5 sqmm FRLSH PVC insulated unsheathed multi strand copper cable (1100 V) for line conductor and 2.5 Sqmm FRLSH PVC insulated unsheathed solid copper cable (1100 Volts) for earth continuty wire for one 15/16 amp multi socket out let on independent board. 46 Supply and fixed switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. 47 Supply & Fixingsocketoutlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and as directed.( For Same Board only) 48 Supply and fix switch socket combination 2 in 1 multipurpose5 pin , (6 Amps ) flush typecontrolled by one switch complete all as specified. 49 Supply and fixed switch socket combination5 in 1 , 6 pin , (5/16 Amps ) flush typecontrolled by one switch complete all as specified. 50 Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified. 51 Supply and fixing lamp holder, PVC/polycarbomate type with back plate straoght of angle suitable for LED lamp with LED bulb 12 watt complete all as specified and directed. 52 Supply & fixed stepped type electronic fan regulator flush type 120W, 240 Volts ISI marked complete all as specified. 53 Supply and fixing for concealedtype sub main wiring with two run of 6.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and includingthrough Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxesetc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc.including one run of 6.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCconduit shall be measured as unit length. (ii)Cost of PVC conduit, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. 54 Supply & fixingLED security light 60 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with BIS approved driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 115 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as perlatest IS. operational voltage of 170 volts to 270 volts, frequency of 50 Hz,protection grade IP 66, IK-08 CRI greater than or equal to 70%, CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wireof 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified.Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However,as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked Date of installation and Date of Procurement with marker pen 55 S&F in repairs LED 20 Watt tube light fittingintregatedtype, includingLED retrofit tubelamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingcomplete all as specified & directed..Note (i) Make of batten and LED tube lamp should be of same make. 56 Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 35/36 watt recess mounting of size 600 mm x 600 mm , , LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz,lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by EIC. 57 M&L taking down of ceiling fans of any sweep and transportation to work shopincluding dismantling for repair/overhauling, oiling, greasing, vernishing andreplacementofunserviceable accessories like capacitor, connector etc. After repair re-assembling fan, testingfor efficient functioning including 2.5mfd capacitor and connector,hanging it back in position and provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan , complete all as specified and as directed by Engrs-in-Charge. 58 S&F in repairs VTPN distribution board with provision for 4 pole MCCB up to 160A as incomer with three phase and single phase (TP/SP) MCB outgoing with and including insulated busbar (tinned electrolytic copper) arrangement, shrouded neutral bar and earth bars, Top and bottom removable gland plates with knockouts, 6 way,Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge 59 Supply and fix in repairs MCCB 4 pole , 415 volts of capacity 100 Amps with breaking capacity of 25 kA fixed thermal and fixed magnatic setting including necessary connection complete all as specified and as directed. 60 Supply and fixing in repairsMCB TPN 40 to 100 Amps,C curve 10kA, 415 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 61 S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed . 62 Supply and fixedin repairs MCB SPN 40-63 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectioncomplete all as specified and directed by Engr-in-charge. 63 Supply and fixedin repairs MCB SP 6-32 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectioncomplete all as specified and directed by Engr-in-charge. 64 S&F in repairs sheet metal enclosure (Plug & Socket) withand including 20 Amp MCB and two pin and earth plug and socket complete with one single pole MCB complete all as specified and as directed. 65 S & F in repairs building security light angle bracket made of 40 mm dia GI Tubes, light grade galvanised, with all fitting clamps, nut bolt and fixedto walls complete all as specified and directed by Engr-in-charge. 66 Supply and Fixing in repairs Air termination single pointed aluminium rod 12mm dia and 300mm long connected with 20 mm GI pipe complete all as specified and as directed. 67 Supply and Fixing in repairs of aluminium strip size 25x3mm with saddles and fixing screws etc. for roof conductors above ground complete all as specified and as directed. 68 M&L for earthing complete with galvanised steel earth plate electrodesize 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specifiedNOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:-1. The unit rate includes for protection GI pipe of 40 mm and watering pipeof 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock.2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high.3.The cost ofGI strip of size 32 x 6 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer.5. Cost ofwelding and nut bolts are deemed to be included in the unit rate. 69 Supply and fixing in repairsTest point terminal block made of gun metal or phosphorous bronze size 75x75x25mm drilled and screwed including 3 nos of 8mm dia 25mm long hex. head brass screw complete all as specified and as directed. 70 Material andlabour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mmmm buried directly in ground (Earthpit not less than2.25m below ground level) with top edge of theplate not less than 1.5m below normal groundlevel, connected to GI wire 4 mmasearth lead by means of bolt, nuts, check nutsandwashers of galvanised iron or steel, upto 7.5mlength, earth strip protected by andincluding 15 mm diaGI pipe (light grade) andconnected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC(1:3:6)type C1 , Precast RCC(1:2:4)TypeB1 coverslab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100mm C/C bothwayswith onehandle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm boreGI Pipe (Medium Grade) for watering, Charcoal andsalt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any typeof soil anddisposal of spoil to a distance n.exc50 m andnecessary testing complete all asshown in Electrical Plate No 3 of SSRPart-I.NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wire of 32x6mm including protection pipe,from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
Contract Date: Jan 03, 2026 Contract Value : 40.39 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
West Bengal View Result →
6.
Health and Family Welfare #7411295 AOC
Tender For Mgps Works At Konni Medical College Phase Ii - The humidifier bottle is made of unbreakable & reusable polycarbonate /polysulfone material autoclavable at 121 degree centigrade . 2 Humidifier Bottle should be covered under warranty & CMC. 3 It should have any of the following valid certficates as class II medical device:(i) CDSCO licence (or) (ii) USFDA (or) (iii) CE certified with 4 digit notified body no(or) (iv) BIS approval Note: Copy of the certificate should be submitted along with the technical bid 4 Ward Vacuum Unit:Supply, installation, testing and commissiong of Ward Vacuum Unit as per specification given below: 5 It must consists of the following:- 6 1no of Suction Regulator and 1no of1000 ml polysulfone /polycarbonate collection jar. 7 Suction regulator should be supplied with a safety jar, including and antibacterial filter and an anti-overflow safety device. Should have wide membrane continuous suction controller 8 Should have vacuum levels: 0-750 mm Hg or more 9 Should have vacuum gauge fitted with a protective bumper device. 10 Should have on/off knob allowing for the quick restoration of a readjusted vacuum level. 11 Must have central adjustment knob with a color coded for 0 to 750 mm Hg or more. Should have Polysulfone/ polycarbonate 100cc safety jar, autoclavable at 121º C at 5mins,unbreakable, fitted with an anti-overflow safety device and equipped withantibacterial filter. It should be totally transparent, to ensure perfect sucked liquid visibility. 12 It should have any of the following valid certficates as class II medical device:(i) CDSCO licence (or) (ii) USFDA (or) (iii) CE certified with 4 digit notified body no(or) (iv) BIS approval Note: Copy of the certificate should be submitted along with the technical bid 13 Copper Pipes 14 Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper pipes, as per specification given below: 15 42mm OD X 1.2mm thick 16 35mm OD X 1.2mm thick 17 28mm OD X 1.2mm thick 18 22mm OD X 1mm thick 19 15mm OD X1 mm thick 20 12mm OD X1 mm thick 21 Copper pipe should be as per standard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to the standard. All copper pipes should be degreased & delivered capped at both ends. The pipes should be accompanied with manufacturers test certificate for the physical properties & chemical composition. 22 Copper pipe must have reputed third party inspection certificate (Eg. Lloyd’s or TUV or SGS). 23 Fittings should be made of copper and suitable for a working Pressure of up to 17bar and especially made for brazed socket type connections. All valves shall be pneumatically tested for twice the working pressure and factory degreased for medical gas service. 24 Copper fittings should comply with EN 1254:1 factory degreased and brazing filler metals should comply with EN 1044. Fitting should be degreased, individually packed for medical use. 25 The minimum thickness of copper pipes of 35mm and above outer diameter, should be 1.2mm and the thickness of copper pipes less than 28mm outer diameter, should be 1mm as mentioned in respective Institute’s BOQ. 26 Installation & testing: 27 Installation of piping shall be carried out with utmost cleanliness. Only pipes, fittings and valves that have been degreased and fittings shall be used at site. Pipe fixing clamps shall be of nonferrous or non-deteriorating plastic suitable for the diameter of the pipe. 28 Inert gas welding technique should be used by passing oxygen Free Nitrogen Gas inside the copper pipes during silver brazing, in order to avoid carbon deposition inside the copper pipes. Only copper-to-copper joints are permitted on site except threaded or flanged joints may be made where pipelines are connected to items such as valves and control equipment. No flux shall be used for joining Copper to Copper joints and on for joints made on site. Copper to copper joints shall be brazed using a 5% silver-copper phosphorous brazing alloy CP104. A total of 5 joints shall be cut out for examination to establish the quality of the joints being made on site. The insides shall be clean and free from oxides and particulate matter and the minimum penetration of the brazing alloy at any point shall be three times the wall thickness of the tube. If the joints examined do not conform to these requirements, then adjacent joints shall be cut out and examined until the extent of faulty workmanship has been made good. Copper-to-brass or gunmetal joints shall only be made under controlled conditions off site. The joints are ordinarily used to join short copper pipe tails to brass, gunmetal or bronze fittings to permit their connection into the pipeline. The sub-assemblies shall be degreased and individually sealed in bags or boxes before delivery to site. 29 Adequate supports should be provided while laying pipelines to ensure that the pipes do not sag. Suitable sleeves shall be provided wherever pipes cross through walls / slabs. All pipe clamps shall be non-reactive to copper. 30 After erection, the pipes are to be flushed with dry nitrogen gas and then pressure tested with dry nitrogen at a pressure equal to twice the working pressure or 150 psig, whichever is higher for a period of not less than 24 hours. 31 Length and quantity of individual items (Copper pipes, AVSUs, Alarm panels, Isolation valves, Outlets, pendants etc.) are mentioned. However quantity will be calculated and paid at actuals. Bidder should quote unit price for all the items as detailed 32 Maximum interval between supports (Horizontal and Vertical) : 12mm Pipe - 1.5m, 15mm pipe - 1.5m, 22mm pipe – 2m, 28mm pipe-2m, 35mm pipe-2.5m, 42mm pipe -2.5m, 54mm pipe - 2.5m, 76mm pipe – 3m 33 Painting :All the pipes from manifold/plant upto the outlets should be painted with two coats of synthetic enamel paint and colour codification should be as per standards followed and in with consultation with HITES EIC /Institute. 34 Gas Outlet Points/ Terminal Units with probe: Supply,Installation, testing and commissioning of Gas outlet points for Oxygen, Nitrous Oxide, Medical Air 4 Bar , Vacuum, CO2 and AGSS, as per specification given below: 35 Oxygen outlet with probe 36 Medical Air 4 outlet with probe 37 Vacuumoutlet with probe 38 Terminal Units (Gas Outlets) with probes/Adaptors for O2,Compressed Air 4, Vacuum 39 The Medical gas outlets shall confirm to HTM 02-01/ NFPA 99 C/EN/DIN/ ISO 7396-1. Front Loading Type Terminal Outlets should be designed to dispense medical gases (or an inlet for medical vacuum) to the secondary equipment (flow meters, Suction regulators, etc.) at the point of use and is gas specific so that secondary devices cannot be “attached” to the wrong gas. When not in use the gas in a non-flowing state within the Outlet (Terminal unit) sealed by “O” ring. The adapter when inserted pushes the poppet inside and the gas starts flowing and sealing is ensured by the “O” ring or a seat. The Outlets are Quick Connect Type and gas specificity is accomplished by Pin indexing.The outlets should have following features: 40 • Push to insert and press-to-release mechanism for probes. 41 • Allows plugging of probes from front. 42 • Self-sealing valve on disengaging the probe (Quick disconnect) 43 • Smooth quite action. 44 • Non return valve for on line servicing/ repairing 45 • Indexed to eliminate inter-changeability of gas services 46 • Color-coded gas specific front plate 47 • Totally leak proof, safe & easy to operate 48 • Configurations possible: surface, flush & Bead-head. 49 • Outlets shall fully comply with the requirements of the HTM 02-01/ NFPA 99 C/EN/DIN/ISO 7396-1.It should have any of the following valid certficates as class II medical device :(i) CDSCO licence (or) (ii) USFDA (or) (iii) CE certified with 4 digit notified body no (or) (iv) BIS approval Note: Copy of the certificate should be submitted along with the technical bid 50 •All outlets should have respective labels (i.e.O2 /Air4 /Vacuum etc.) displayed accordingly. 51 AREA VALVE BOX (WITH VALVES):Supply,Installation, testing and commissioning of Area Valve Boxes. as per specification 52 Valve Box - 2 Gas Service with NIST Connection 53 Valve Box - 3 Gas Service with NIST Connection 54 Area valve service units should fully comply and meet with HTM 02-01/NFPA 99C/EN/DIN/ISO7396-1. It should provide a zone isolation facility for use either in an emergency or for maintenance purpose The Area Valve Service Unit should incorporate a ball valve in a lockable box with emergency access. It should be reliable and easy to operate, easy purge, sample & pressure testing and emergency supply system. 55 Medical gas/vacuum services should be fixed copper, piped to and from their respective area valve service units. A color coded service identity label should be fitted behind the valve handle. The unit should provide a zone isolation facility. Gas Flow direction should be indicated. 56 The box shall be made from extruded aluminium to prevent corrosion. All wetted parts (except seals and gaskets) should be brass or copper. Each unit assembly should be factory tested for gas tightness. Rubber pipe grommets should be provided to ensure any leaking gas does not escape from the unit into a wall cavity. All visible aluminum surfaces should be powder coated. 57 Master Alarm Panel 58 Master Alarm (Digital) 59 It should have any of the following valid certficates as class II medical device :(i) CDSCO licence (or) (ii) USFDA (or) (iii) CE certified with 4 digit notified body no (or) (iv) BIS approval Note: Copy of the certificate should be submitted along with the technical bid 60 Shall fully comply with HTM 02-01 / NFPA 99C/EN/DIN/ ISO 7396-1 Standards. 61 Each Master Alarm should be modular in design and be fitted with required number of master alarm modules. The master alarms should be capable to monitor minimum 20 Point. 62 Each point represents an alarm condition that the source equipment might have. When an alarm condition exists, a red light flashes and the audible alarm sounds. If several alarm conditions occur simultaneously, the most recent alarm light should flash, while the other alarm lights should remain lit. When an alarm condition is created, an audible alarm should be actuated. A dry contact module should be available to interface with a building management system. 63 The box material should be of gauge steel of requisite thickness and equipped with mounting brackets. The emissions from alarms should conform with applicable standards. 64 Master alarm management system should be designed to display alarm conditions from the source supply units indicating the broad status of the source equipment and manifolds as well as the master distribution status from the source supplies. Depending on the alarm priority, a visual and audible alarm should be initiated to indicate an alarm condition. 65 Each panel shall display and/or input up to twenty point alarms. Panel should be ready to use with BMS system. 66 The master alarm must be able to monitor the following source alarm conditions: 67 · Oxygen Source Empty/Fault 68 · Oxygen Cylinder Bank Empty/Fault 69 · Oxygen Emergency Bank Empty/Fault 70 · Air Compressor Faulty/Operation 71 · Vacuum Pump Faulty/Operational 72 · Vacuum Deficiency Vacuum Reservoir 73 · And Other MGPS Signals & Alarms 74 Bidder shall be responsible for connecting all cabling from local area alarm panels to master alarm panel . 75 Master alarm should be integrated with BMS/HIS 76 MEDICAL GAS ALARM PANEL:Supply, Installation, testing and commissioning ofMedical Gas Alarm Panel, as per specification given below: 77 Medical Gas Area Alarm for2 services (Oxygen and MA4 bar) 78 Medical Gas Area Alarm for3 services (Oxygen, MA4 barand Vacuum) 79 The medical gas central alarms should be capable of monitoring up to 5 medical gas services (As specified in BOQ of respective institute) by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital display of pressures. The medical gas area alarm should fully satisfy the HTM 02-01/ NFPA 99 C/EN/DIN/ISO 7396-1 requirements and shall fully comply with the requirements of the HTM 02-01/ NFPA 99 C/EN/DIN/ISO 7396-1.It should have any of the following valid certficates as class II medical device:(i) CDSCO licence (or) (ii) USFDA (or) (iii) CE certified with 4 digit notified body no (or) (iv) BIS approval Note: Copy of the certificate should be submitted along with the technical bid 80 An audible warning should sound simultaneously with any failure indication and a mute facility should be provided. 81 Note: The bidder may offer combined unit of AVSU & alarm, bidder has to match the quantiy of AVSU/Alarm whichever is higher 82 LINE ISOLATION VALVES: Supply, Installation, testing and commissioning of Line Isolation Valves, as per specification given below: 83 15 mm ball valve 84 22 mm ball valve 85 28 mm ball valve 86 35 mm ball valve 87 Line Isoltaion valves: The Lockable line valves must degreesed and complete valve with stuffed pipe & fittings, factory tested and complies with HTM 02-01/ NFPA 99 C/EN/DIN/ISO 7396-1 standard. 88 Supply, installation, testing and commissioning of Medical gas hose assemblies as per standard followed as per specification given below: 89 High pressure tubes for O2, Compressed Air,& Vacuum 90 It should be colour coded for individual services i.e. white for Oxygen, Yellow for Vacuum, Black for air. Antistatic rubber tube should be as per ISO standards. It should have applicable certification. 91 TOTAL AMOUNT (EXCLUDING GST)
Contract Date: May 29, 2025 Contract Value : 51.96 Lakh
Government Departments No of Bidders 5
Contract Date: Ref. Documents Contract Value : 76.62 Lakh
Government Departments No of Bidders 6
Madhya Pradesh View Result →
8.
Defence #6877460 AOC
Repair And Maintenance Of Unserviceable Units Of Dg Sets,Amf Panel And Allied Items At 2 Wing At Afs Pune And Maintenance,Repair And Replacement Of Def Items Of Earthing, Lightning Protection System At 2Wing Afs Pune Under Ge Af Lohegaon--1.00 M&L for servicing of DG set 6.25 KVA to 40 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items 2. Spares like nuts,bolts etc shall be included in the rate quoted above) 2.00 M&L for servicing of DG set 62.5 KVA to 125 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Spares like nuts,bolts etc shall be included in the rate quoted above) 3.00 M&L for servicing of DG set 160 KVA to 250 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items 2.Spares like nuts,bolts etc shall be included in the rate quoted above) 4.00 M&L for servicing of DG set 320 KVA to 400 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items 2. Spares like nuts,bolts etc shall be included in the rate quoted above) 5.00 M&L for servicing of DG set 500 KVA to 750 KVA by taking out U/S spares, Cleaning by brushing to remove dust including replacing of diesel filters,lub oil filters,checking of all nuts, bolts tightening wherever necessary,draining out old engine oil and coolant and filling new engine oil and coolant as required at site, adjustment and replacement of belt,tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking for smooth functioning of DG Set ( Note :- 1.Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured separately under respective items .2. Spares like nuts,bolts etc shall be included in the rate quoted above) 6.00 Material only for the following item of DG set 6.25 KVA to 40 KVA to be incorporated in repairs. 7.00 (a) Fuel Filter 8.00 (b)Oil Filter element with O ring 9.00 (c) Fan belt 10.00 (d) Alternator belt 11.00 (e) Radiator hose pipe inlet/outlet 12.00 (f) Solenoid switch 12 volts,DC 13.00 (g) Oil Pressure Pipe 14.00 (h) Fuel Pressure Pipe 15.00 Material only for the following item of DG set 62.5 KVA to 125 KVA DG set be incorporated in repairs for item No 2 16.00 (a) Fuel Filter 17.00 (b)Oil Filter element with O ring 18.00 (c) Fan belt 19.00 (d) Alternator belt 20.00 (e) Radiator hose pipe inlet/outlet 21.00 (f) Solenoid switch 12 volts,DC 22.00 (g) Oil Pressure Pipe 23.00 (h) Fuel Pressure Pipe 24.00 Material only for the following item of DG set 160 KVA to 250 KVA to be incorporated in repairs for item No 3 25.00 (a) Fuel Filter 26.00 (b)Oil Filter element with O ring 27.00 (c) Fan belt 28.00 (d) Alternator belt 29.00 (e) Radiator hose pipe inlet/outlet 30.00 (f) Solenoid switch 12/24 volts,DC 31.00 (g) Oil Pressure Pipe 32.00 (h) Fuel Pressure Pipe 33.00 Material only for the following item of DG set 320 KVA to 400 KVA to be incorporated in repairs for item No 4 34.00 (a) Fuel Filter 35.00 (b) Oil Filter element with O ring 36.00 (c) Fan belt 37.00 (d) Alternator belt 38.00 (e) Radiator hose pipe inlet/outlet 39.00 (f) Solenoid switch 24 volts,DC 40.00 (g) Oil Pressure Pipe 41.00 (h) Fuel Pressure Pipe 42.00 Material only for the following item of DG set 500 KVA to 750 KVA to be incorporated in repairs for item No 5 43.00 (a) Fuel Filter 44.00 (b)Oil Filter element with O ring 45.00 M &L for Removing the fuel injection pump (FIP) & injectors from DG set cap 62.5 KVA to 160 KVA and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set. 46.00 M &L for Removing the fuel injection pump (FIP) & injectors from DG set cap 160 KVA to 250 KVA and carry out servicing and calibration including replacement of injectors nozzles, etc. and refitting the same for smooth and efficient functioning all as directed by Engr-in-Charge. Note :-Repairs will be carried out from authorised workshop of MICO or manufacturer of DG set. 47.00 Taking down defective self starter 12 Volt of DG set of cap from 20KVA to 160 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning in all respect all as directed by Eng-in-Charge.Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after. 48.00 (a) Rewinding the burnt field coil. 49.00 (b) Rewinding the burnt armature coil with commutator. 50.00 (c) Replacement of bush/ bearing. 51.00 (d) Replace the worm out carbon brush with brush holder. 52.00 (e) Replacement of clutch. 53.00 (f) Replacement of solenoid switch. 54.00 (g) Replacement of Bentex drive. 55.00 Taking down defective self starter 24 Volt of DG set of cap from 200 KVA to 500 KVA DG set installed at various installations and servicing/overhauling including replacing of worn out parts like solenoid, bearing, carbon brush, rewinding the starter motor winding, etc. and refitting the same after making serviceable for smooth functioning in all respect all as directed by Eng-in-Charge.Note:-Spares required and rewinding will be measured and paid separately under relevant item of this Schedule here after. 56.00 (a) Rewinding the burnt field coil. 57.00 (b) Rewinding the burnt armature coil with commutator. 58.00 (c) Replacement of bush/ bearing. 59.00 (d) Replace the worm out carbon brush with brush holder. 60.00 (e) Replacement of clutch. 61.00 (f) Replacement of solenoid switch. 62.00 (g) Replacement of Bentex drive. 63.00 M&L for disconnecting the U/S alternator capacity of 30 KVA to 160 KVA, 3 phase any make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engineer-in-charge. 64.00 M&L for disconnecting the U/S alternator capacity of 200 KVA to 250 KVA, 3 phase any make & type from engine, transporting to workshop dismantling it for repairing and rewinding by taking out burnt armature winding aleaning the alternator coil with existing gauge/size of super enamelled copper winding wire, providing new insulation, sleeves, varnishing cotton taping etc reassembling the alternator complete including aligning with engine and testing in all aspects for smooth functioning all as specified and directed by Engineer-in-charge. 65.00 Taking down old US contactor and S&F new contactor for the following range : 66.00 (i) Contactor 40A, 415 volt, 4 pole 67.00 (ii) Contactor 63A, 415 volt, 4 pole 68.00 (iii) Contactor 80A, 415 volt, 4 pole 69.00 (iv) Contactor 130A, 415 volt, 4 pole 70.00 (v) Contactor 160A, 415 volt, 4 pole 2NO+2NC 71.00 (vi) Contactor 255 A, 415 volt, 4 pole 2NO+2NC 72.00 (vii) Contactor 400 A, 415 volt, 4 pole 2NO+2NC 73.00 Taking down old US CONTACTOR COIL and S&F new contactor coil for the following range : 74.00 (i) Contactor coil of 130A, 415 volt, 4 pole 75.00 (ii) Contactor coil of 160A, 415 volt, 4 pole 76.00 (iii) Contactor coil of 255A, 415 volt, 4 pole 77.00 (iv) Contactor coil of 325A, 415 volt, 4 pole 78.00 (v) Contactor coil of 600A, 415 volt, 4 pole 79.00 Material and labour for replacement of battery charger 12 Volt,10 Amp and making all electrical connection testing complete all as directed 80.00 Material and labour for replacement of battery charger 24 Volt, 10 Amp and making all electrical connection testing complete all as directed 81.00 M & L for replacement of brass battery terminal suitable for lead Acid Battery 12 V 40 AH to 12 V , 180 AH. 82.00 M & L for maintenance servicing and complete checking of automatic main failure (AMF) panel of any capacity including replacement of worn out parts, copper cables, relay of suitable range, toggle switches, indicator & repair of Ammeter, Voltmeter complete and testing all as specified & directed at site by Engr-in-charge.Note :- Spare parts required will be measured and paid separately under relevant item of this Schedule here after. 83.00 (a) CTs of range 62.5 to 400 KVA 84.00 (b) Relay of range 62.5 KVA to 400 KVA. 85.00 (c) Copper wire single core for internal connection. 86.00 (d) Voltage monitoring relay (digital type) 87.00 (e) DG set AMF Contactor as per existing 88.00 M&L for taking out diesel from the fuel tank of DG set of capacity 20 KVA to 160 KVA and cleaning the fuel tank complete of any size. 89.00 M&L for taking out diesel from the fuel tank of DG set of capacity 200 KVA to 500 KVA and cleaning the fuel tank complete of any size. 90.00 M&L for De-scaling & cleaning , painting (except fins area) & welding / soldering / brazing of radiator of any capacity & any type complete all as directed. 91.00 Supply only coolant for radiators of DG sets of capacity 30 KVA to 750 KVA complete all as directed at site. 92.00 Supply only battery distilled water for batteries of DG sets 93.00 M&L for draining out old engine oil and filling new engine oil of grade as recommended by manufacturer for DG set any make and capacity complete all as directed by Engr-in-Charge. 94.00 S & F in replacement of fuel indication transparent plastic tube of any size as per existing complete all as directed 95.00 Supply and fix in replacement of broken acoustic enclosure door hinges with stainless steel hinges complete with nut bolts etc as per site requirement of any type, cap and make of DG set all as directed at site. 96.00 Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 62.5 KVA to 160 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint as specified and directed at site by Engr-in Charge. 97.00 Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 160 KVA to 500 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint as specified and directed at site by Engr-in Charge. 98.00 Taking down old rusted unserviceable silencer single/double with exhaust pipe and M&L for new silencer with Exhaust pipe complete bends, coupling etc suitable for 100 to 400 KVA DG set including fixing arrangements and painting with silver colour over a coat of red oxide all as specified and directed 99.00 Supply & Fix in replacement of automatic voltage regulator 62.5 to 400 KVA DG set complete all as directed. 100.00 Material and labour for taking shutdown and disconnecting cables from AMF panel and DG set of 62.5 KVA and dismantle the spare parts of any make and type and disconnect the engine from the alternator and transport it to the workshop if requiired and conduct engine overhauling of DG set and replace all the unserviceable spare parts with the new one and reassembling of complete DG set and testing commisioning complete all as specified and directed by OEM and Engr-In-charge.Note:- Cost of spare parts will be measured and paid seperately under relevant item of this Schedule here after. 101.00 Supply only nozzle including testing complete all as specified and directed by Engr-In-charge. 102.00 Suply only Piston Ring set complete all as specified and directed by Engr-In-charge. 103.00 Supply only Piston asy complete all as specified and directed by Engr-In-charge. 104.00 Supply only Liner with O-Ring 105.00 Supply only Head gasket complete all as specified and directed by Engr-In-charge. 106.00 Supply only Fuel gasket complete all as specified and directed by Engr-In-charge. 107.00 Supply only CR Bearing set complete all as specified and directed by Engr-In-charge. 108.00 Supply only Inlet valve complete all as specified and directed by Engr-In-charge. 109.00 Supply only exhaust valve complete all as specified and directed by Engr-In-charge. 110.00 Supply only Head repairing complete all as specified and directed by Engr-In-charge. 111.00 Supply only engine head assy complete all as specified and directed by Engr-In-charge. 112.00 Supply only engine oil seal complete all as specified and directed by Engr-In-charge. 113.00 Supply only valve seal complete all as specified and directed by OEM and Engr-In-charge. 114.00 Supply only valve spring complete all as specified and directed by Engr-In-charge. 115.00 M&L for replacement of valvel guide complete all as specified and directed by Engr-In-charge. 116.00 Supply and fixing of 180 AH sealed lead acid battery 12 volt into DG set with all necessary connections complete all as specified and directed by Engr-in-Charge 117.00 Supply and fixing of 150 AH sealed lead acid battery 12 volt into DG set with all necessary connections complete all as specified and directed by Engr-in-Charge 118.00 Labour only for comprehensive maintenance of and attending day to day break down of DG Set including servicing including first hand repairs, consisting of normal repairs such as tightening of nut bolts, greasing, checking/replacing of battery terminals, levelling of distilled water, cleaning of main ,battery charging alternator where ever exists with vacuum cleaner complete all as specified & directed by Engineer-in-charge. Note:-(i) The maintenance cost of DG Set shall deemed to comprises of cost of labour employed for the purpose, T&P used and other petty items such as cotton waste, Kerosene oil, Grease, nuts, bolts and labour cost for fixing spares. (ii) All spares and oil replaced will be measured and paid under relevant items of schedule ‘A’.(iii) Non attending the complaint with in 8 Hrs @ Rs. 2000.00/day shall be recovered by the contractor.(iv) Keep the complaint pending after one day @ Rs.4000.00/day shall be recovered by the contractor.(v) The complaint shall be generated by Telephonically/Verbally by concern JE E/M or Engr-Incharge.(vi) Spares shall be measured and paid separately. 119.00 (a) 6.25 KVA to 40 KVA 120.00 (b) 62.5 KVA to 125 KVA 121.00 (c) 160 KVA to 250 KVA 122.00 (d) 320 to 400 KVA 123.00 (d) 500 KVA to 750 KVA 124.00 Material and labour for Checking/ Testing of resistance value of any type of earth pits by disconnecting earth continuity conductor from test terminal block/panel/equipment at various location of AF Station Pune and reconnecting the earth continuity conductor after testing.Temporary earthing connection to be provided while testing.Earth tester will be provided by contractor. Earth tester must be calibrated.Earth test to be signed by Rep of contractor, Rep of MES and Rep of AF. Test reports to be submitted in triplicate complete all as specified and directed. 125.00 M&L for maintenance of GI Plate/copper plate earthing to improve the earth resistance as following:-(a) Remove the earth chamber carefully for reuse.(b) Excavation in any type of soil and rock 0.5 cum (approx 0.75m x 0.75m x 0.9m depth )(c) On First day recharge the earth pit with common salt, Magnesium sulphate,back fill compound mixed with water.(Approx salt- 10 kg, Mg sulphate- 10 kg, charcoal - 10 kg )(d) On the next day recharge the earth pit with water 500 ltrs.(e) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(f) Refill the pit with black cotton soil (M&L for black cotton soil must be included in the quoted rate)(g) Refit the earth chamber in place.(h) Material and labour for Testing of earth must be included in the quoted rate.Note:-(i) Common salt, Mg sulphate, charcoal will be measured and paid separately.(ii) If existing chamber is already damaged then new chamber will be provided, measured & paid separately.. 126.00 M&L for fixing earth indicators made out of 3 mm thick MS sheet of size 200 mm x 300 mm duly fixed in MS angle iron 25 mm x 25mm x 3mm of 600 mm long fixed to ground by means and including necessary cement concrete foundation and painting with one coat of synthetic enamel paint over a coat of red oxide primer complete for writing earth reading and connected plant/ panel etc. and excavation and earth work complete all as specified and directed. 127.00 S&F in repair of test point made out of gun metal or phosphorous bronze of size 75x50x5mm duly mounted on epoxy insulator 02 Nos.Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal blockmade out of M.S sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer complete all as specified and directed. 128.00 M&L for supply, installation, testing and commissioning of pure copper pipe electrode earthing maintenance free earthing based on 6 mtr long copper pipe 76 mm dia(ID) with wall thickness of 3 mm, copper strip 32x 6 mm ( strip in pipe type electrode )and copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the copper pipe elecrode . Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore.Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.Copper strip must be connected with copper pipe electrode and at other joints through brass nut bolt all as specified and directed. 129.00 M&L for supply, installation, testing and commissioning of copper bonded(254 micron) pipe electrode earthing maintenance free earthing based on 6 mtr long copper bonded pipe 76mm dia(ID) , copper strip 32x 6 mm ( strip in pipe type electrode )and copper coated pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the copper pipe elecrode . Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore.Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.Copper strip must be connected with copper pipe electrode and at other joints through brass nut bolt complete all as specified and directed. 130.00 M&L for supply, installation, testing and commissioning of pure copper pipe electrode earthing maintenance free earthing based on 3 mtr long copper pipe 76 mm dia(ID) with wall thickness of 3 mm, copper strip 32x 6 mm ( strip in pipe type electrode )and pure copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 60 KGS approx of BFC shall be filled around the copper pipe elecrode . Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed. Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore.Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.Copper strip must be connected with copper pipe electrode and at other joints through brass nut bolt complete all as specified and directed. 131.00 Material and labour for supply, installation, testing and commissioning of GI pipe electrode earthing maintenance free earthing based on 6 mtr long GI pipe 76 mm dia(ID) medium grade, GI strip 32x6 mm (Strip in pipe type electrode) and GI pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the GI pipe electrode. Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed.Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore. Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.GI strip must be connected with GI pipe electrode and other joints through GI nut bolt complete all as specified and directed. 132.00 M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, checknuts & washers of copper and connecting to test point , providing charcoal and common salt ,all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including copper earth strip 20 x 3 mm , 7.5 meter long, etc complete all as specified and directed. Note- (i) Vendors are bound to get earthing result less than or upto1 Ohm with or without the grid of earthing.(Maximum number of new earthings in grid are restricted to 3 nos) Any additional work and material required to achieve the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(iii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate) 133.00 M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32x6 mm ,7.5 meter long, etc complete all as specified and directed. Note:(i) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled.(ii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate) 134.00 S & F GI earth continuity conductor or main earthing lead of size 25X4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed. 135.00 S & F copper earth continuity conductor or main earthing lead of size 20x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed. 136.00 S & F GI wire 4mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed. 137.00 Taking down carefully from roof / wall of the building loose / hanging / deshaped / GI strip/ aluminium strip / copper strips of any size & type including unserviceable insulators etc complete all as specified and directed. 138.00 S&F GI Sheet funnel with wire mesh complete all as specified and directed. 139.00 Taking down termination rod complete all as specified and directed. 140.00 Refixing serviceable aluminium /Copper/Galvanised Iron strips of any size and fixing on porecelin insulators T type placed not more than 50 cm apart & fixed with srews & nut bolts complete all as specified and directed.Note : M&L Porcelain insulators with nuts bolts and screws will measured and paid separately 141.00 Supply & fix aluminium strips 25x3 mm on porceline insulator T type not more than 50 cm apart complete all as specified and directed.Note: M&L Porcelain insulators with nuts bolts and screws will measured and paid separately 142.00 Supply and fix air termination single pointed aluminium 12 mm dia & 300 mm long including nuts & bolts for fixing air termination rod to pole/ pipe duly insulated by providing appropriate insulator all as required at site. complete all as specified and directed. 143.00 M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as mass concrete for foundation of GI tubing /Air termination rod complete all as specified and directed. 144.00 S&F GI socket reducer 40x25 mm and aluminium gutka externally threaded suitable for 25 mm GI socket and internally threaded suitable for fixing epoxy insulator for fixing terminal rod complete all as specified and directed.(As per sample). Note: Material and labour for epoxy insulator is included in the rate quoted by the tenderer. 145.00 S&F GI pipe medium grade 40 mm dia embeded in concrete complete all as specified and directed.(mounting arrangment for air termination) Note: M&L for PCC work will be measured and paid separately. 146.00 S&F in repair of GI tubing 15 mm bore medium grade including all necessaory fittings i.e. socket, elbow etc.laid on floor or fixed to wall complete all as specified and directed. 147.00 Material and labour for welding in joints of GI Strip any size and after welding testing and commessioning will be carried out and result will be recorreced complete all as specified and directed 148.00 Material and labour for brezing in joints of Copper Strip any size and after brezing testing and commessioning will be carried out and result will be recorreced complete all as specified and directed 149.00 S&F in repair of GI tubing 15 mm bore medium grade including all necessaory fittings i.e. socket, elbow etc.laid in trenches complete all as specified and directed. 150.00 S&F Stop valve of 15mm dia complete all as specified and directed. 151.00 Supply and fix Bib tap 15 mm bore size of cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed 152.00 M&L for Cutting the existing GI pipe upto 80mm for tapping of 15 mm branch including required fittings complete all as specified and as directed. 153.00 S&F epoxy insulators suitable of aluminium strip of 25x3mm size with nut bolts/ screws for fixing of copper/ aluminium / GI strips on stone / PCC block walls etc complete all as specified and directed. 154.00 M&L for earthing chamber of size 450x450x300 mm depth outside & 250x250x300 mm depth of PCC (1:3:6) type C1 complete all as specified and directed. 155.00 S&F in repair of earthing pit cover 50 mm thick precast slab of RCC 1:2:4 type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm incl 6 mm dia bar handle complete all as specified and directed. 156.00 Supplying and fixing of common salt for earthing maintenance complete all as specified and directed. 157.00 Supply and fixing of of magnesium sulphate for earthing complete all as specified and directed. 158.00 Supply and fixing of Charcoal for earthing complete all as specified and directed.
Contract Date: Feb 11, 2025 Contract Value : 31.47 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 58.62 Lakh
Government Departments No of Bidders 5
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 36.52 Lakh
Government Departments No of Bidders 9
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 60.33 Lakh
Government Departments No of Bidders 7
Madhya Pradesh View Result →
12.
Defence #5481597 AOC
Tender For Special Repair To Earthling Infrastructure At Various Location And Provn Of Footpath On Road At Afs Jalahalli ; 1 Supply, installation, testing & commissioning of maintenance free chemicalearthing system in repair comprising of 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installationcomplete all as specified and directed.Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO. 2 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. 3 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. 4 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 5 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with sample approval. 6 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. 7 (vi) Copper strip of size 20 x 3 mm (99.99% molecularly copper) shouldbe fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM will be considered in unit quoted rate and extra will be measured and paid separately). 8 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concerned. 9 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. 10 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 11 (x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 12 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock. 13 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained. 14 (xiii) A security deposit of value equal to 2.5 % of the rate quoted for each chemical earthingeach earthing shall be retained from payment due to the contractor from final bill for the guarantee period. 15 (xiv) The electrode shallcarry manufacturers name . 16 (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. 17 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. 18 (xvii)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. 19 (xviii)The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material along with sample approval. 20 (xix) Sign boardof mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed . 21 Material and labour for Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer. 22 S&F Copper strip 20 x 3mm thick (99.99% molecularly copper) as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing. 23 Material and labour as in repair for Earthpit indicator for existing earthing pit made out of 16 mm dia and 60 cm long MS Squre Bar embeded in PCC (1:3:6) type C-1 using 20 mm graded stone agreegate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 250X300X 3 mm thick fixed on side of earth pit cover complete painting and writingover the plate ie. Type , Result, Date of measurement and pit numberwith Black beground with white and complete all as specified and as directed by Engineer-in -charge. 24 Supply and fixing test point terminal block made of gun metal or phosphorous bronze, size 75mm x 75mm x 25 mm thick, drilled and screwed including 3 Nos. 8 mm dia. 25 mm long hexagonal head screws, including taking down old unserviceable one,complete all as specified and directed. 25 Supply and fixing in repair for aluminium earth continuity conductor or main earthing lead fixed to wall /roof top offor lightning arrester /fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, aluminium using porcelain clit/post insulators with screw / selfdril GIscrew with rubber washer , complete all as specified and directed. 26 Supply and fixingin repair Air termination, single pointed, alluminium rod 12 mm dia and 300mm longfixed to GI Strip / Alluminium strip including nuts,bolts & washersfor earth conductivity to ground complete all as specified and as directed. 27 Supply and fixingin repair for GI earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6 mm thick,Galvanisedusing porcelain clit/post insulators, complete all as specified and directed. 28 Supply and laying in repair copper bonded round conductor rod of 10mm dia for connecting the earthling pits together using exothermic welding joint complete all as specified and directed. 29 Supply and fixingin repair Air termination, single pointed, copper rod 12 mm dia (99.99% molecularly copper) and 300mm longfixed to GI Strip / Alluminium strip including nuts,bolts & washersfor earth conductivity to ground complete all as specified and as directed. 30 Supply and fixingin repair for GI earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 4 mm thick,Galvanisedusing porcelain clit/post insulators, complete all as specified and directed. 31 Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting in soft /loose soil and removing the surplus material (Soil) from the site complete all as specified and as directed. 32 M&L Hard core of gauge n.exe.63mm with broken stone boulders, deposited spread and levelled in layers not exe 15 cm thick watered and rolled rammed to a true surfaces complete all as specified and as directed. 33 M&L for 75mm thick cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed. 34 M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade over sand cushion with grey cement and no pigment complete all as specified and as directed. 35 M & L for Sand filling under floors or in foundations including watering and consolidation all as specified and directed. 36 M&L for precast kerb stone with PCC (1:2:4) type B1 using 20mm graded stone aggregate finished even and fair without using extra cement including demolition ofold kerb stone (un reinforced) of any description and in anypositionnot otherwise specifically provided complete all as specified and directed. 37 Dismantling posts or struts (wood, steel, or RCC) any section, any length n exc 5m including taking out embedded portion in concrete, brick work, masonry etc and all as specified and directed. and incl neccessary excavation for new post holesall as specified and directed. 38 M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation filling and for mass concreteincluding demolition ofConcrete (un reinforced) of any description and in anypositionnot otherwise specifically provided complete all as specified and directed. . 39 S & FMS angle iron Hand rails, fencing posts, flat iron including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 40 Dismantling of existing fencing wire mesh of any type etc..and re-fixingold retrieved fencing in new positionn including line wires, any mesh, size and type to standards, rails, straining bolts, etc inlcuding provision of binding wire and complete all as specified and directed. 41 Supply and fixingMS round bars/strengthening bar 10mm dia & over cut to length bent to shape required and fixed with necessary arrangement as per site reqiurementquality confirming to Fe-410W(grade E-250)Quality A or Fe 290 (gde-E-165) all as specified and directed. 42 M & L Providing two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces all as specified and directed. 43 Supply and fixingFlat iron welded or jointed in connection with framed work including securing bolts and all necessary drilling, bolting or reverting and similar work conforming to Fe-410-0 complete all as specified and directed 44 Supply and fixing chain link of MS galvanised fencing any size or typeincluding line wires, any mesh, size and type to standards, rails, straining bolts and necessary MS round bar as per site requirement complete all as specified and directed. Note :- An amount of Rs 275490.00 on account of credit schedule for schedule A part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
Contract Date: Dec 18, 2024 Contract Value : 49.92 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 10
TenderDetail