View Bid Results For Pcb Carrier Tenders

We found 184 Bid Results related to pcb carrier tenders. You can find Contractor details who won pcb carrier tenders along with contract details in Bid awards announcements section.

Filters
Stage
147
20
17
Tender Publishing Platform
42
142
State / UT
29
25
24
22
22
14
11
9
8
6
6
6
5
3
3
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
Contract Value
55
43
67
17
Publish Date
0
0
0
0
0
Sector
19
42
31
30
18
15
12
5
5
4
4
3
3
3
3
2
1
1
1
1
Ownership
6
76
51
33
20
3
1
Within keyword
Active filters:
Showing 1–4 of 184 tenders matching your filters
2.
Agriculture #11328645 AOC
Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Duvcon,Indosaw Moisture Meter; Duvcon,Indosaw; Annual Maintenance Contract (Amc); Quarterly; Yes - Maintenance Service/ Repair Of Moisture Metre (Mm) , Repair Of Mm Printer , Repair Of Power Adapter Of Mm (9V) , Repair Of Power Adapter Of Mm Printer (5V) , Repair Of Mm Printer Data Cable (Rs 232) , Repair Of Operating/ Ratchet Handle , 74148 , 1-K , 10K Present , 14 Pin Dip Ic Holder , 16 Pin Dip Holder , 203, 105, 502, 503 Tre Ot , 22 Ohm , 25 V, 10 Uf , 25V, 100 Uf , 25V, 470 Uf , 28 Pin Dip Holder , 4.7 K Network Resistance , 40 Pin Handle , 40 Pin Header Set , 40 Pin Male Header , 470 Ohm 1% Tolerance , 5V Dpdt , Atmega 328P Set , Base Plate Complete , Battery Compartment , Bell Switch , Beveal Gear , Bevel Pin , Bevel Pinion , Bottom Plunger , Bracket , Buzzer , Carrier Handle , Com. Meggar Box , Complete Pcb With Printer Facility , Complete Sticker (Duvcon) , Complete Sticker (Indosaw) , Connector Lead 12 Pins , Connector Lead 2/3 Pins , Crystal 6.144 Mhz , Dc Socket/ Phono Socket , Electronic Switch , Eprom , F.N.D. Board , Guide Nut , Ic 146818A , Ic 4051 , Ic 7135 , Ic 74373 , Ic 7447 , Ic 7448 , Ic 7600 , Ic 7660 , Ic 7805/ Ic Regulator 7805 , Ic Base 16 Pins , Ic Base 20 Pin , Ic Base 28 Pins , Ic Base 8 Pin , Insulation Disc , Keypad (Duvcon) , Keypad (Indosaw) , Keypad Duvcon , Lcd/ Led/ Pcb Display , Lead Screw , Max 232 , Max 8031/ Micro Controller , Mm Body (Duvcon) , Mm Body (Indowsaw) , Module Cell For Date & Time , Pcb Press Switch , Pinion Bush , Pointer , Pre Volt Circuit Set , Pressue Plate , Printer Ic , Printer Port , Relay , Rice Module , S 9014 , S9014 , Spur Gear , Spur Gear Axle , Spur Pinion , Switching Transistor (Bc 107) , Temprature Sensor , Test Cup , Test Cup Handle , Thrust Bearing , Timer Ic 7555 , Transformer , Trimpot 1M, 5K, 20 K Or 50 K , Volume Cup A , Volume Cup B , Volume Cup C , Wire 1.25 , Wooden Base , Lcd Controller , Display Ic , Ratchet Handle , Supply Set , Cell Leak Proof 1.5V , Oil & Greasing , Ic 7400 , Funnel Strip , Complete Gear Set , Electronic Led Card , Ad Converter
Contract Date: Ref. Documents Contract Value : 10,693
Boards / Undertakings / PSU No of Bidders 3
3.
Educational and Research Institute #11323155 Technical Bid
Tender for Supply Of Equipment For Electronics And Cmmunication Engineering Department: (As Per Specification And Nit) , Supply Of Equipment For Electronics And Cmmunication Engineering Department , 8051 Micro Controller Kit : Specification : • Operating Voltage: +5 V Dc. • Flash Memory: 4 Kb (At89c51) / 8 Kb (At89s52). • Ram: 128 Bytes Internal Ram. • 16 × 2 Alphanumeric Lcd Display .• Push Buttons / Tactile Switches. • Dip Switches For Digital Input .• Inbuilt Adc Interface: Ldr, Potentiometer. • Inbuilt Dac Interface .• Inbuilt Stepper Motor Driver With Stepper Motor .• Inbuilt Dc Motor Driver With Dc Motor. • 1 × 4 Led Array, 1 × 4 Keypad, 1 × Relay. • 1 × Buzzer, 16 × 2 Lcd Display, 1 × Pwm Driver. • 1 × Hardware Interrupt Key, Inbuilt Rtc. • Inbuilt Eeprom And Uart Module. • 4 × 7-Segment Display. • Supports Both Assembly And C Language Programming. • Pc Interfaceable. , Temperaturemeasurementkitspecification : • Sensors: Rtd (Pt-100), Thermocouple (Fe-K/J-Type), And/Or Thermistor (Ntc). • Display: 3½ Digit Led/Lcd Digital Display (Typically 200 Mv Fsd). • Temperature Source: Portable Water Kettle Or Heater Block. • Signal Conditioning: On-Board Circuitry For Amplification, Linearization, And Cold Junction Compensation. • Test Points: Multiple 2 Mm / 4 Mm Banana Sockets For Monitoring Input/Output Signals. • Power Supply: 230 V Ac, 50 Hz, Single-Phase. • Accessories: Glass Thermometer, 10 K Ntc Thermistor Probe, K-Type Thermocouple Probe, Patch Cords And User Manual. , Ask Modulationanddemodulation Kit: Specification : • Message Signal1: 8-Bit Variable Data,Amplitude 5V. • Message Signal 2: Debounced Data, Amplitude Low (0) And High (5 V). • Message Signal 3: Fixed Data 25 Khz, 12.5 Khz, 6.25 Khz, 3.12 Khz, Amplitude 5 V. • Carrier Signal: Sine Wave, Frequency 200 Khz, Amplitude 5 V. • Modulator Type: Switching Modulator Using Analog Switch / Transistor Switching Ic. • Demodulator: Envelope Detector And Lpf. • Comparator: Lm311 Based. • Supply Voltage (Board): +12 V, +5 V Dc. • Supply Current: 100 Ma Minimum. • Input Voltage: 230 V Ac, 50 Hz. • Interface Connectors: 2 Mm Banana Socket. , Dth Trainer Kit: Specification :Power Supply:• 200 V To 240 V Ac, 50 Hz.Dish Antenna: • 1.5 Ft Aluminium Steerable Dish Antenna.Lnb (Low Noise Block Down Converter): • Input Frequency: Ku-Band.• Output Frequency: 950 Mhz To 1450 Mhz. • Conversion Gain: 65 Db.• Noise Temperature: 35 K (Max).Set-Top Box Receiver In Trainer Form:• If Frequency: 70 Mhz.• Video Bandwidth: 50 Hz To 5 Mhz. • Video Output Level: 1 Vpp At 75 Ω Load. • Video Polarity: Normal/Inverted, Switch Selectable. • Audio Subcarrier Frequency:Tunable From 5.0 Mhz To 8.0 Mhz.• Remote Control Provided.• Hdmi Cable: 10 M. Controls:• Channel Selection.• Volume Control. Fault Simulation:• Five Built-In Simulated Faults For Troubleshootingexperiments.• If Signal Disconnected.• Video Output Fault.• Audio Mute Fault.• Tuner Misalignment.• Rf Output Interruption.Pcb Size: • 15 × 12 With Multicolour Section-Wise Block Diagram.Standard Accessories:• 1.5 Ft Dish Antenna.• Lnb.• Trainer Pcb.• Dish Connecting Wire.• Audio-Video Cable.• User Manual.• Acrylic Cover.• Hardware Materials For Assembly Of Dish Antenna.Additional Features:• Dth Subscription Connection Withdoordarshanfree Channels. • Free-To-Air Channel Demonstration. , Fpga Trainer Kit: Specification : • Must Use Industry-Standard Mid-Range Fpga Device • Usb-Jtag Programmable, Compatible With Vivado Ise (Webpack). • Power Supply: 5 V Dc Through Usb Or External Adapter. • On-Board Peripherals: Leds, Switches, Push Buttons, 7-Segment Display,Clock Source, Gpio / Pmod Expansion Ports, Uart, Vga / Hdmi, Usbuart Bridge, Usb Cable. •User Manual.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
4.
Educational and Research Institute #11277940 Technical Bid
Tender For Purchase Of Lab Equipments-- 1 Purchase Of Lab Equipments 2 Ask Modulation And Demodulation Kitspecifications:• Message Signal1: 8-Bit Variable Data,Amplitude 5V. • Message Signal 2: Debounced Data, Amplitude Low (0) And High (5 V). • Message Signal 3: Fixed Data 25 Khz, 12.5 Khz, 6.25 Khz, 3.12 Khz, Amplitude 5 V. • Carrier Signal: Sine Wave, Frequency 200 Khz, Amplitude 5 V. • Modulator Type: Switching Modulator Using Analog Switch / Transistor Switching Ic. • Demodulator: Envelope Detector And Lpf. • Comparator: Lm311 Based. • Supply Voltage (Board): +12 V, +5 V Dc. • Supply Current: 100 Ma Minimum. • Input Voltage: 230 V Ac, 50 Hz. • Interface Connectors: 2 Mm Banana Socket. 3 Fiber Optic Communication Trainer Kitspecifications:Power Supply: • 230 V Ac ±10%, 50 Hz Mains Operation. • Built-In Regulated Power Supply. Optical Transmitters: • Led Transmitter: 660 Nm. Optical Receivers: • Phototransistor / Pin Photodiode Receiver. • Built-In Signal Conditioning And Amplifier Circuits. • Audio Power Amplifier With Speaker/Headphone Output. • Comparator / Pulse Shaping Circuit For Digital Signal Recovery. • Test Points For Cro Observation And Signal Monitoring. Fiber Media: • Multimode Plastic Optical Fiber (Pof). • Fiber Patch Cords With Connectors. Signal Sources: • Built-In Sine Wave Generator. • Built-In Square Wave / Digital Pulse Generator. • Voice Signal Input Through Built-In Microphone/Audio Source. Trainer Features: • Separate Transmitter And Receiver Sections. • On-Board Test Points For Signal Observation. • Led Indicators For Signal Monitoring. • Fault Simulation Facility. • Compact Tabletop Modular Design. • Circuit Diagram Printed On Pcb. Bandwidth: • Analog Bandwidth: Up To 350 Khz. • Digital Bandwidth: Up To 2.5 Mhz. Controls: • Variable Signal Amplitude Control. • Variable Frequency Control. • Optical Intensity Adjustment. Standard Accessories: • Patch Cords And Connectors. • Power Cord. • Audio Connecting Cable. • User Manual. Please Enable Macros To View Boq Information = Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
7.
Heavy Industries and Public Enterprises #11209194 AOC
Bids Are Invited For Carrier Card Pcb Assembly Total Quantity : 414
Contract Date: Ref. Documents Contract Value : 39.31 Lakh
Boards / Undertakings / PSU No of Bidders 3
9.
Educational and Research Institute #11161433 Price Bid
Procurement Of Equipment, Instruments, Machinery, Tools Etc. Related To Laboratories And Workshops Of Electronics And Telecommunication Engg., Engineering Physics, Engineering Mechanics Of Mirik Government Polytechnic, Mirik, Dist. Darjeeling, 734214 , Spherometer (Screw Pitch 0.05 Mm And Lc 0.005 Mm) , Concave Mirror (Focal Length 20 Cm) , Convex Mirror (Focal Length 20 Cm) , Concave Surface (Focal Length 20 Cm Diameter 50 Mm) , Hooks Law Apparatus (Consisting Of 30 Cm Long Mirror Scale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand) , Mercury (Distilled Liquid Mercury, Grade Std.-Biotech Grade) , Flywheel Apparatus (Thickness: 4.4 Cm Diameter :20 Cm) , Cantilever (Length 100 Cm, Hook At One End, C Clamp) , Light Weight Hanger (Metal Slotted Weight Mechanics Physics Experiment Equipment Set With Hook With Weight Of Each Mass Of The Order Of 50Gm Or 100 Gm) , Inverse Square Law Apparatus (Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter) , Stopwatch (Digital Stopwatch With Ms Count) , High Resistance Box (Resistance Box Plug With 1 To 10 K Ohm Resistance) , Winch Crab Single Purchase With Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut.String, Weight Box With Pan. ] , Winch Crab Double Purchase Without Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut. ] , Worm And Worm Wheel Single Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Worm And Worm Wheel Double Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Wheel & Axle Simple Without Weight [Standard Setup For Lab.] , Simple Screw Jack With Weight [Experiment Set Up Screw Jack ( Weights)All Metallic Construction Accurately Machine Cut Screw With A Pitch Of 5 Mm Carrying A Double Fanged Turn Table Of About 20 Cm Diameter. Fitted On A Heavy Cast Iron Base And Complete With Two Adjustable Pulleys, Cord And Hook. Weights Are Included.] , Combined Inclined Plane & Friction Slide Apparatus Iron Base & With Weight [Standard Setup For Lab.] , Parallel Forces Apparatus [Experiment Set Up Simple Supported Best Type Supported At Its End. For Verification Of Condition Of Equilibrium Of Parallel Forces, Law Of Lever & Forces On Beam Etc. Consisting Of Two Compression Thrust Type 10 Kg Tubular Spring Balances Fixed On Wooden Polished Board, A Wooden Beam With Steel Back Plate. Complete With Two Strups, Hooks & Two 10Kg Weights. ] , To Verify Lami’S Theorem [Gravesand Apparatusboard: Wooden With Metal Base Pulley: Z-Pullies (2 Nos) With Adjustable Distance Weight Set: 5X50 G (3 Sets). ] , Simple Jib Crane Apparatus Iron Stand With Weight [Experiment Set Upwith Consisting Of A Tubular Compression Balance, Pivoted About An Axis Fitted To The Base. The Tie Chain Has An Adjustable Angle Bracket And Fitted With A 10Kg Extension Balance. Completion Wooden Base With 1.2 Meter Jib. With Weights. ] , Mini Drafter, T Square, Protractor, Set Squares, Compass, Divider [Made Out Of Wood. To Be Used In Chalk Board] , Model Of Geometric Constriction (Solid Cube, Solid Primed, Cylinder, Cone, Hexagon, Tetrahedron ) [Made Out Of Wood. To Be Used In Chalk Board] , Amplitude Modulation And Demodulation Trainer Kit [Message Signal:100 Hz To 2.8 Khz, Carrier Signal 28 Khz To 108 Khz,Modulation : Balanced Modulator, Amplifier : Op Amp Based, Demodulation : Diode Detector & Lpf(6Th Order)] , Frequency Modulation Anddemodulation Kit [On-Board Message Signal With Variable Amp/Freq,On Board Carrier Signal Fm Modulation Using Xr 2206Ic,Demodulation Using Pll Detector And Lpf 4Th Order Lpf,Internal Power Supply +5V , +12V/ 500 Ma] , Super Heterodyne Am Radio Receiver Trainer Kit To Measure Sensitivity, Selectivity And Fidelity [On Board Variable Capacitor Tuning,Receiving Antenna,Local Oscillator,Bfo, Rf Amplifier, Mixer,If Amplifiers, Detectors, Agc,Audio O/P Amplifier, Speaker.Frequency Range: 400Khz To 1700Khz,If Frequency: 455 Khz.] , Pam, Pwm And Ppm Modulation And Demodulation Trainer Kit [Provides Sine Waveform Output Of 250Hz, 500Hz, 1 Khz, And 2 Khz With Amplitude Adjustments Of 0 - 5Vp-P. Switch Selectable Sampling Clock Of 4, 8, 16, 32 Khz. On-Board Features Analog Sample Circuit/Output, Sample & Hold Circuit/Output, Flat Top Circuit/Output, 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz.] , Analog Signal Sampling & Reconstruction Trainer Kit [±15V D.C. At 100Ma, Ic Regulated Power Supply, A.F. Signal Generator For Modulating Signal.Sampling Clock Generator To Provide Sampling Clock And Gate Pulse. Modulator Circuit For Flat-Top Natural And S/H Circuit. Demodulator Circuit To Reconstruct Input (Sinewave)] , Telephone Receiver Trainer Kit [Line In Section : One Dot Line Connection Port.Handset : One Handset Connection Port. Keyboard : 4X3 Matrix Keyboard.Dialer : Tone And Pulse. Facilities : Redial Up To 32 Digits, Mute, Redial, Flash, Pause Switches.Indicators : Line In, Hook, Tone And Ringer, Call Mute Section.Control : Ringer Volume Control, Ringer Speed Control.Speech Path : Fully Non-Blocking.Dial Pulse Ratio : 10 Pps + / - 10%.] , 100Mhz Digital Oscilloscope [Bandwidth: 100 Mhz, 2 Analog Channels+ Ext With Probes Included Rise Time: =3.5 Ns, Real-Time Sample Rate Of 1 Gsa/S 1% Dc Gain Accuracy Should Support Rs232/Uart, I2c And Spi Bus Triggers And Decodes Usb And Ethernet Connectivity] , 30Mhz Analog Cro [Dual Trace Dual Channel Oscilloscope. Bandwidth: 20Mhz. Full Bandwidth Sweeping Circuit , Tv-H / Tv-V Synchronization And Trigger-Lock To Observe All Kinds Of Signals Stably. Y Deflection Operation: Y1, Y2, Alt, Chop, Add, Mode.Horizontal Sweep Mode: Auto, Trig, Lock, Single.X-Y Mode Input: X-Axis Yi And Y-Axis Y2.] , 2 Mhz Function Generator [Frequency: 1Hz – 2 Mhz Sine, Square, Triangle, Ttl Output] , Digital Storage Oscilloscope (100 Mhz) [Bandwidth 100 Mhz, Channels: 2+, Display: Tft Color Lcd Of Suitable Size (Capacitive Touchscreen). Sampling Rate: 1 Gsa/S Real Time, Sampling Mode: Normal, Average (2, 4, 8, 16, 32, 64, 128, 256), Peak Detect. Mathematics: A+B, A-B, A×B, Fft (Fast Fourier Transform). Fft Windows: Rectangle, Hanning, Hamming, Blackman. Auto Measurement: Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1-2 (Rise), Delay1-2(Fall) ] , Trainer Kit For Rectifier With And Without Capacitor Filter For : — (A) Half-Wave Rectifier, (B) Full-Wave Rectifier, (C) Bridge Rectifier [Transformer Rating : 9-0-9V/200Ma, Rectifiers : Half Wave; Full Wave - Bridge, Center Tapped Rectifier,On-Board Dc Voltmeter : 0 - 20V,On-Board Ac Voltmeter : 0 - 20V,Load : Variable Resistive Load 10K,Filter Circuit : In-Built- Capacitor (3Nos.),In-Built- Inductor (1No.),Input Line Voltage : 230V Ac ± 10%, 50Hz] , Push-Pull Amplifier Trainer Kit [I.C Regulated Power Supply : +6 V.Digital Ac Voltmeter: 0 – 20 V.Digital Ac Milliammeter : 0 – 200 Ma.Set Of Resistances.Set Of Capacitors.Two Transistors Cl 100 And Ck 100.Connecting Wire.] , Fet Characteristics Trainer Kit [Variable Dc Regulated Power Supply Of 0-5V At 250Ma. Dual Range Dc Voltmeter Of 1.5V/15V.Dc Ammeter Of 0-20Ma.] , To Determine Frequency Response Characteristics Of Rc Coupled Amplifier Circuit And Calculation Of Bandwidth, Midband Gain, Input Impedance And Output Impedance For: (A) Single-Stage Amplifier (B) Double-Stage Amplifier [Sine Wave Oscillator 15Hz To 150Khz In Four Ranges With Amplifier & Amplitude Adjustable.Three Decade Resistances Bank In Steps Of 1K, 10K & 100K Per Steps Total Step 30.Two Pnp Transistors.] , Mosfet Characteristics Trainer Kit [On Board Ammeter And Voltmeter,Dual Variable Dc Power Supplies,On Board Mosfet And Fet With Resistors To Perform Experiments] , To Study The Input And Output Characteristics And To Find The H-Parameters Of A Bjt For : — (A) C-E Configuration, (B) C-C Configuration, (C) C-B Configuration [Power Supply 1) 0-1V Dc 2) 0-10V Dc.Meters Dc 65Mm Four Dial V, V , Ma Ua/ Ma.Transistor Cl100/ Similar] , Component Development System [Power Supplies On Boards 0-15 V And 0-30 V, 250 Ma Each Variable.Fixed Dc Regulated Power Supplies 15 V/250 Ma And 5 V/250 Ma.Ac Power Supply 15-0-15 V For Rectifier Applications.Various Components On The Trainer Set. ] , Kcl & Kvl Trainer Kit [Two Dc Ic Regulated Power Supplies 0-12 V/150 Ma, Two Mr65 Square/Digital Meters For Voltage & Current Measurement, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Power Cords 230 V, 50 Hz] , Thevenin’S And Norton’S Theorems Trainer Kit [Power Supply 2?3?0?V, Regulated & Short Circuit Proof Variable Dc Voltage Source – 01 No. Fixed Resistance Of Different Values. Dc Voltmeter.Dc Ammeter. Glass Fuse For Short Circuit Protection. On/Off Switch With Indication Light. Patch Cords Suitable To The Terminals With Board For Easy Interconnection.All Above Accessories Will Be Fitted On Bakelite Sheet Fixed On Box.] , Superposition Theorem Trainer Kit [Instrument Comprises Of Two Fixed Output Dc Regulated Power Suppliesof 12V & 5V At 500 Ma Current, Three Moving Coilmeter, Circuit Diagram Printed On The Front Panel & Connections Ofsupplies, Meter & Resistances Brought Out At 4Mm Sockets. ] , Maximum Power Transfer Theorem Trainer Kit [Ammeter 30Ma Dc. Voltmeter 12V Dc. Power Supplies: Dc Supply Ic Regulated 0-12V Dc, 150Ma. Operated On Mains Power 230V, 50Hz +10% Components Are Mounted On The Panels Are: Resistances 2Watts Variable Resistor Voltage Control Through Potentiometer. Fuse For Short Circuit Protection. Patch Cords 4Mm.] , Reciprocity Theorem Trainer Kit [Instrument Comprises Of One Fixed Output Dc Power Supply Of 12V At 300 Ma Current, Two Moving Coil Meters, Circuit Diagram Printed On The Fornt Panel & Connections Of Supplies, Meters & Resistances Brought On Terminals.] , Series And Parallel Resonant Circuit Trainer Kit [Analog Meters: Ammeter 20Ma Ac. Voltmeter 20V Ac. Components Mounted On The Panels Are: 3 Nos. Of Resistors Selected By Rotary Switch. 3 Nos. Of Capacitors Selected By Rotary Switch. 3 Nos. Of Inductors Selected By Rotary Switch.] , Low Pass And High Pass Filter( Rc & Lc) Constant K Type Trainer Kit [Instrument Comprises Low Pass Circuit Rc Type Instrument Comprises Low Pass Circuit Lc Type Instrument Comprises High Pass Circuit Rc Type Instrument Comprises High Pass Circuit Lc Type Instrument Fitted In Highly Shockproof Plastics Box] , T And ? Type Attenuator Trainer Kit [Instrument Comprises Ofdc Ic Regulated Power Supplies 0-15V/150Ma. Two Mr65 Square / Digital / Round Meters For Voltage & Current Measurement. T And Pie Network Provided On The Board. Variable Resistor Using Band Switch Is Mounted On The Board. Instrument Fitted In Highly Shockproof Plastics Box. Sufficient No Of 4Mm Patch Cords For Interconnection Instruction Manual For Student Workbook. Power Cords 230V, 50Hz] , To Study Standing Wave Pattern For A Transmission Line Of Finite Length With: (A) Open Termination, (B) Short Termination, And © Matched Termination. [Transmission Line : Coaxial Cable 100M ( 25M X 4 Nos) Impedance Matching Resistance : 0 To 100 ( 02 Nos ) Test Generator : 1. Sine Wave : 4 Khz To 4 Mhz. 2. Square Wave : 10 Khz. Interconnections : 4 Mm Sockets On All Input / Output Connections. Test Points : 10 On Board Circuit Mimic : Illustrates Functional Blocks For Ease Of Experimentation Power Requirement : 230V 10% 50Hz, 1 Ac. Accessories Provided : I. Set Of Patch Cords. Ii. Bnc To Bnc Cable. Iii. Bnc To Crocodile. Iv. Detailed Instruction Manual.] , Digital Trainer Kit (Experiment 1. -To Verify The Truth Table Of Not, Or, And, Nand, Nor, Xor, X-Nor With Ttl Logic Gates And Cmos Logic Gates. Experiment 2.- To Realize Different Boolean Expressions With Logic Gates. Experiment 3.-To Realize Half-Adder, Full-Adder, Subtractor, Parallel And Serial Full-Adder. Experiment 4-To Design 1’S Complement, 2’S Complement And 9’S Complement Adder-Subtractor.) [Dc +5V , 400Ma; Dc +12V, 250Ma; Dc -12 V, 250Ma, Dc0 To + 30V: Variable 100Ma,Ac Output: 12V-Ct-12V, 150Ma; Logic Data 8-Bit Debounced Set/Clear Ttl Output With Bicolour Led; Clock Generator I Hz To 200Khz Variable & Manual, Ttl & /Ttl(Complement) With Bicolour Led;Logic Probes 8-Bit 3-State Led Display High, Low, High Impedance; Function Generator Sine, Square, Triangle, 1 Hz To 250 Khz;Bread Boards : 3 X 820 Tie-Points; Total Short Circuit Protection From Any To Any Point On Board] , Complete Setup To Implement The Truth Table Of Encoder,Decoder, Multiplexer And De-Multiplexer. [The Trainer Kit Should Be Able To Verify The Truth Tables Of Truth Table Ofencoder,Decoder, Multiplexer And De-Multiplexer.] , Complete Setup To Design/Construct Parity Generator, Checker And Comparator. [Industry Standard Specification To Perform Relevant Experiments. ] , Flip Flop Trainer Kit [Kit For Verification Of Jk, Sr, D, And T Flip-Flop Truth Tables] , Complete Setup To Design / Construct Binary Synchronous And Asynchronous Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design / Construct Programmable Up/Down Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design Controlled Shift Register And Study Their Function. [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Study Different Memory Ics [Industry Standard Specification To Perform Relevant Experiments. ] , A/D & D/A Converter Trainer [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Interface Ttl And Cmos Ics. [Industry Standard Specification To Perform Relevant Experiments. ] , 8051 Trainer Kit [Operating Frequency : 10Mhz Crystal,40-Pin Ic Base | 40Pin-Zif Socket,2×16 Char Lcd Display,32 I/O Pins,32Kb-Sram,32Kb-Eeprom.] , Ct-31/51 Or 8031/51 Microcontroller Trainer Kit With Led Display, Usb Interface & Inbuilt Power Supply [Operating At 10/12 Mhz, On Board 8K Ram,8/16K Bytes Of Eeprom,48 I/O Lines,Hexadecimal Keyboard And Six Seven Segment Displays,Rs-232C Interface,Usb Interface] , Ct-31/51Lcdadu8031/51 Microcontroller Trainer With Lcd Display, Usb Interface, Adc, Dac& Inbuilt Power Supply [Trainer Based On 8051/89C52 Microcontroller.On Board 32K Ram.64 K Bytes Of Eeprom.20 X 2 Lcd Display.48 I/O Lines. Onboard Adc & Dac.] , Adc Interface Module [Usb Interface, Adc Module Module 10 Channel 12Bit Ad Sampling Data Acquisition Stm32 Uart Communication Adc Module] , Dac Interface Module [Operating Voltage 2.7-5.5 V. Interface Type I2c. Resolution 12 Bits.] , Lcd Display Module [Display Contents :16 * 2 Characters (5*8 Dots ). Lcd Size :80 X 36 Mm .Lcd Thickness :9.5 Mm.] , Keyboard Interface Module [5X4 Keys Matrix Keyboard. ] , Dc Motor Controller Module [Driver Module : L298n. Motor Supply Voltage (Max.): 46V.Motor Supply Current (Max.): 2A. ] , Stepper Motor Controller Interface Module [Robocraze Stepper Motor(28Ybj-48 Dc 5V 4 Phase 5 Wire) + Uln2003 Driver Board Compatible With Arduino] , Trafic Light Controller Module [Led Traffic Lights Signal Module/Digital Signal Output Traffic Light Module] , Temperature Measurement Module [Electrobot Dht11 Digital Temperature & Humidity Sensor Module For Arduino And Rpi] , Operational Amplifier Trainer Kit ( Ic 741 ) [Inbuilt Variable/Fixed Dc Regulated Power Supplies.Output Voltages : 0-5Vdc (2Nos.) (Variable), +12Vdc (Fixed).Transistor & Components Provided Ic : 741.Transistor : Cl 100 (Npn).] , Active Filter Trainer Kit (Lpf, Hpf, Bpf) [Opamp Based First Order Lpf, Hpf, Bof Trainer Kit (Mi-A14)] , Application Of Ic555 Timer Trainer Kit (Astable & Monostable Mv) [In-Built Regulated Dc Power Supply.On Board Manual Pulse Generator For Triggering The Monostable And Bistable Circuit.Inbuilt Led Output Indicator.Symbols And Diagram Are Printed On Glass Epoxy Pcb.] , Opamp Based Oscillator Trainer Kit ((A) Hartley, (B) Colpitt, (C) Phase Shift, (D) Wein Bridge) [Op-Amp Oscillator Trainer Mi-A13. Frequency 50-60 Mhz.] , Crystal Oscillator Trainer Kit (741 Based) [Industry Standard Specification To Perform Relevant Experiments. ] , Function Generation Kit (Using Icl8038) [Icl8038 Function Signal Generator Sine Triangle Wave Kit Diy Professional K5e8.Uses Icl8038 And High-Speed Op Amp, Higher Accuracy. Low Distortion Sine Wave: 1%.] , Voltage Regulator Trainer Kit (Using Ic723) [0-35V D.C. At 250Ma, Countinously Variable Unregulated Power Supply.D.C. Milliammeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 50Ma And 250Ma.D.C. Voltmeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 10V And 40V.Ic 723 Fitted On Base.Three Potentiometers.] , Function Generator Trainer Kit [Frequency Ranges: 1? Hz To 1?0? Hz, 1?0? Hz To 1?0?0? Hz Fuse:3?5?0? Ma, Slow Blow Automation Grade: Manual Power Supply:Max 2?3?0?V Ac, 5?0? Hz +/- 1?0?%] , Maxwells Bridge Trainer Kit [The Kit Contains A Bridge With Provision For Connections Of Capacitors And An Unknown Inductor. In Built Ac Supply [ 1 Khz And 2 Vpp ] And Dc Supply [ +5 V ] On Board. Two Nos Dial Resistances [ 50 Ohm To 200 Ohm ] And [ 1 Ohm To 11 Ohm ] In Step. A Dc And Ac Null Detector Using Selector Switch. A Dial Type Variable Capacitor [ Range 0.2 Uf Ro 1.2 Uf ] And Six Nos. Unknown Inductors [ Range 1 Mh To 12 Mh ].] , Lvdt Trainer Kit [Excitation Source Built In Ac Source 2.5 Khz Sine Approx. L.V.D.T. In Non Metallic Structure. Micrometer One (For Displacement) Displacement Range 10Mm. Test Points Sockets At Different Places For Signals. Potentiometer Two For Zero & Calibration Adjust Display (Mm) 3.5 Digit Digital Power Supply Ic Regulated Phase Detection Balanced Demodulator Power Supply Short Circuit &Overload Protected Mains 230V/50Hz Ac] , Strain Gauge Trainer Kit [Strain Gauge: 4 Mounted Upon Cantilever 150X3.5X3.5Mm, Stable Dc Voltage For Strain Gauge Bridge, Opamp Based,Precision Instrumentation Amplifier With Variable Gain,Potentiometer For Zero And Calibration Adjust,3.5 Digit Display For Strain/Weight, 230V 50Hz Ac] , Temperature Transducers Kit Using (A) Rtd (Pt-100) (B) Thermistor. [12 - 0 - -12 V 500Ma To Drive Digital Integrated Circuitry. 5 - 0 - -5 V 250Ma To Drive A To D Converter Signal Conditioning And Amplifying :Analog To Digital Converter. Display : 31/2 Digit Led Display Of 200 Mv Fsd Initial Set : Single Turn Potentiometer To Set Initial Temperature ( Room Temperature) Final Set : Single Turn Potentiometer To Calibrate The Instrument ( Max. Temperature) Select : 2 Way Rotary Switch To Select Rtdand Thermistor. Power On : Rocker Switch To Control Power Supply To The Instrument.] , Calibration Of A Single-Phase Energy Meter By Phantom Loading Trainer Kit [Usage/Application: Lab Experiment Connection:4?-Mm Patch Cord Single Phase Automation Grade:Manual Power:2?0?0? W Voltage:2?2?0?-2?4?0? V] , Calibration Of A Voltmeter Using Crompton Potentiometer Trainer Kit [This Trainer Is Supplied Along With Highly Regulated Dc Power Supplies To Operate The Unit. Further To Calibrate Pmmc Meters, Necessary Ratio Boxes Also Provided. Resistors Used In This Unit For Coarse And Fine Are Very Standard Type Made Of Manganin. This Enable The User To Measure The Potential In A Circuit Close To Micro Volts. Necessary Schematic/Wiring Diagram Printed On The Panel To Follow And Conduct Experiments. User Manual And 4Mm Patch Cords Supplied. Accessories Included: Necessary Dc Power Supplies, Ratio Boxes & Galvanometer Are Provided Alongwith The Unit.] , Cro Demonstration Kit [Crt : 6Rectangular Screen With Internal Graphical 8X10 Division (1Div-1Cm) Vertical Deflection Display : Ch1, Ch2, Add, Alt & Chop Deflection Factor : 5Mv/Div To 5V/Div +3%, 1Mv/Div To 1V/Div, +5% (X5), 10 Steps Rise Time : <17.2Ns Maximum Input Voltage : 250 (Dc + Ac Peak Value) When <1Khz (250V, Dc +Ac) Input Coupling : Ac, Dc & Gnd Polarity Selection : + (Ch2 Only) Display Mode : 1, 10 & X-Y Horizontal Deflection Time Base : 0.2Us/Div To 0.2S/Div, 9 Ranges Sweep Expansion : X10 Accuracy : +3% Triggering Mode : Auto, Norm, Tv-V, Tv-H Triggering Source : Int, Line & Ext. Trigger System Auto : 20Hz-20Mhz Norm : 0.5 Div Int, 0.5 Vp-P Ext Tv-H : At Least 1 Div Or 1 Vp-P Input Impedance : 1Mohm X-Y Phase Difference : <3 Degree, Dc-50 Khz Calibration Waveform : Frequency 1Khz 2%,Voltage 0.5 V 1%, Block Diagram Printed On The Top Panel, Power Requirement: 220 Vac +10% , 50 Hz] , Q-Meter Kit Formeasurement Ofq Of Coils. [Inductance Range:199.9Mµh-19.99H Resistance Range (Ohm):19.99O-19.99M? Capacitance Range:199.9P-1.999?F Capacitance Accuracy: ±(1%±2) Digital Lcr Bridge Meter Power:220 Volts/50Hz ±10%] , Spectrum Analyzer Trainer Kit [Industry Standard Specification To Perform Relevant Experiments. ] , Public Address System Trainer Kit [To Test The Performance Of Loudspeaker And Microphone; Power Output: 100W Rms At 10% Thd Pre-Amplifier Output: 200Mv; Line Output: 1V/ 1K?; Input Channels: Mic: 2Nos; Frequency Response : 65 Hz To 15 Khz +/- 3Db Tone Controls : Bass, Treble, Master 1Control; Speaker Outputs : 4 , 8 , 16 , 70-100V Line Matching; Speakers : 2 Nos; Microphones : 2 Nos(Dynamic Microphone)] , Demonstration Kit Of Black & White Tv Trainer [To Learn The Practical Aspects And Faults Which Would Occur Often In The Black And White Tv. All The Fault Switches Are Provided To Conduct Fault And Observe The Output. The Test Points Are Provided To Determine The Voltages At The Different Sections Of The Tv And Observe The Signal Output Of The Various Sections. The Output Is Monitored On A 20” Picture Tube.] , Demonstration Kit Of Colour Pattern Generator For Colour Tv [They Should Be Able To Make Various Patterns, Including Vertical Bar Patterns, Horizontal Bar Patterns, Circle Patterns, 100% White Patterns, Check Patterns, Horizontal Bar Patterns, Vertical Bar Patterns, Color Bar Patterns, Red Color Patterns, Green Color Patterns, Blue Color Patterns,Yellow Color Patterns, Magenta Color Patterns, And Cyan Color Patterns. Learning Materials To Be Included: Theory, Procedure, Reference Results, Etc.] , Demonstration Kit Of Colour Led Tv Trainer [Display Type: Led; Hd Screen Size: 24 Inch (50Cm) Or More; Display Resolution: 1600 X 900 Pixels Or More; Video Interface: Video Input/ Vga, Hdmi And Or Dvi Input; Audio Output Power: 8W X 2; Receiving System: Pal Bg/I/Dk And Ntsc; Channel Coverage: Vhf-2-12, Uhf21-69; Catv (X~Z+2, S11s41) Mains Supply: 110-260V Ac ± 10%, 50/60Hz; Power Consumption: 35W] , Demonstration Kit Of Dth Trainer Kit [Colour Tft Lcd: 5.7” Tft Lcd; Rf Input: 950 - 2150 Mhz; Rf Output: 470 Mhz Two 862Mhz; Video Output: Pal/Ntsc; Uplink Satellite: Insat 4B; Test Points: 34 Nos.; Included Accessories: Mains Cord, Power Supply, Remote, Dish Antenna With Accessories, Lnb] , Demonstration Kit Of Photocopier [Interface Hi-Speed Usb 2.0 Copy Speed Simplex To Simplex Up To 20 Ppm In A4 (21 Ppm In Letter) Scan Method Color Cis Compatibility Twain, Wia Fault-Creating Facilities For Crum, Thermistor, Stepper Motor, Pickup Clutch, Feed Sensor, Width Sensor, Scanner Stepper Motor, Scanner Sensor, And Printer Door. Various Fault Switch With Test Points Provided On-Board.] , Demonstration Kit Of Fully Automatic Washing Machine Trainer Kit [Semi/Fully Automatic Washing Machine Mechanical Controls 30 Minutes Timer, Wash/Spin Control Atleast 6 Liter Capacity Machine Fault Switches For Wash Motor, Spin Motor, Lid Opening, Buzzer Etc All Faults Are Mounted On Pcb With Enclosure] , Demonstration Kit Of Microwave Oven Trainer Kit [Type: Solo; Capacity: >15 Ltr; Power Consumption: 600 Watt Or More: Child Lock And Alarm, Various Test Points] , Demonstration Kit Of Refrigerator [Industry Standard Specification To Perform Relevant Experiments. ] , Demonstration Kit Of Air Conditioner. [Industry Standard Specification To Perform Relevant Experiments. ] , Tdmpulse Code Modulation Trainer Kit [Crystal Frequency: 12/16 Mhz On Board Generators, 1. Adjustable Amplitude Sine Generator Of 500Hz & I Khz (Synchronised) 2. Variable Amplitude Dc Level (2 Nos.) Input Channels: Two Multiplexing: Time Division Multiplexing Modulation: Pulse Code Modulation Sync Signals: Pseudo Random Sync. Code Modulation Error Check Code: Off, Odd, Even, Hamming Operating Modes: Fast 240 Khz Channel (Approx) And Slow I Khz Channel (Approx) Pc - Pc Communication: 2 Channel Via Rs 232 Baud Rate: Selectable From 300 To 2400 Fault Switches : 8 Nos. Through 8 Way Dip Switch For Troubleshooting At Different Blocks Should Include Various Test Points] , Tdm Pulse Code Demodulation Trainer Kit [2 Channel Time Division Multiplexed Pulse Code Modulation Receiver. Fast (240 Khz/Channel Approx) And Slow (1Hz. /Channel Approx.) Mode Of Operation Pseudo Random Sync. Code Generator For Frame Synchronization. Receiver Clock Generation Using Pll. Error Detection Of None, Even, Odd, Hamming. Error Correction Using The Hamming Code Technique None, Even, Odd, Hamming Parity Selections Two Nos. Of 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz. Four Switched Faults For Fault Selection Block Description Screen Printed On Glassy Epoxy Pcb] , Fdm Transmitter / Receiver Kit [Two Variable Modulating (Sinusoidal) Input Channels With Provision Of Voice Inputs Two Dsbsc Modulators For Frequency Band Translation Of Two Test Signals Two Carrier Generators Two Sets Of Audio Input Amplifier One Adder/Transmission Amplifier Two Demodulators Two Low Pass Filters For Smooth Output] , Ask / Psk / Fsk Modulation And Demodulation Kit [The Kit Should Have An Integrated Ask / Psk / Fsk Modulation And Demodulation. Various Functional Block Diagrams Are Provided On-Board For Teaching/Training. Test Points To Visualize The Signals On Oscilloscopes] , Microwave Test Bench (Klystronbased) [Complete Klystron-Based Test Bench Study Of The Characteristics Of The Klystron Tube And To Determine Its Tuning Range, To Determine The Frequency & Wavelength In A Rectangular Waveguide Working On Te 10 Mode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , Microwave Test Bench (Gunn Based) [To Study The V-I Characteristics Of Gunn Diode, To Study The Voice Communication By Using Microwave Test Bench, To Study The Following Characteristics Of Gunn Diode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , 24 Awg Tinned Single Strand Jumper Wire Spool Blue Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Green Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Red Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Black Colour [90 Meter Spool] , Flexible Electric Wire [2 Core, Twisted Flexible, Red And Black, 0.5 Sq Mm Copper Core, 50M Length] , Soldering Wire [Flux Core, Coil Type (Wire Of 100Gm )] , Inductor 1 Mh [8X10 Mm Radial Leaded Power] , Inductor 10 Mh [8X10 Mm Radial Leaded Power] , Led Red, Green, Blue, White Colour. Fifty Numbers Of Each Colour Led. [0.5W, Through Hole Type] , Ic 7400 [Ttl Ic-Quad 2-Input Nand Gate] , Ic 7402 [Ttl Ic-Quad 2-Input Nor Gate] , Ic 7404 [Ttl Ic-Hex Inverter Gate] , Ic 7408 [Ttl Ic-Quad 2-Input And Gate] , Ic 7432 [Ttl Ic-Quad 2-Input Or Gate] , Ic 7486 [Ttl Ic-Quad 2-Input Xor Gate] , Ic 7474 [Ttl Ic-Dual D Positive Edge Triggered Flip-Flop, Asynchronous Preset And Clear] , Ic 7476 [Ttl Ic-Dual J-K Flip-Flop, Asynchronous Preset And Clear] , Ic 7490 [Ttl Ic-Decade Counter (Separate Divide-By-2 And Divide-By-5 Sections)] , Ic 7495 [Ttl Ic-4-Bit Shift Register, Parallel In, Parallel Out, Serial Input] , Ic 74200 [Ttl Ic-256-Bit Ram (256X1)] , Ic 74147 [Ttl Ic Encoder] , Ic 74138 [Ttl Ic 3 To 8 Line Decoder] , Ic74151 [Ttl Ic Multiplexer] , Ic74138 [Ttl Ic Demultiplexer] , Ic 74169 [Ttl Ic Up-Down Counter] , Ic 74180 [Ttl Ic Parity Checker/Generator] , Ic 74Ls83 [Ttl Full Adder With Carry Ic] , Ic 74330 [Ttl Ic-Pla (12 Inputs, 50 Terms, 6 Outputs)] , Ic 4077 [Cmos Ic Xnor Gate] , Ic 4001 [Cmos Ic Nor Gate] , Ic 4011 [Cmos Ic Nand Gate] , Ic 4070 [Cmos Ic Exor Gate] , Ic 4071 [Cmos Ic Or Gate] , Ic 4077 [Cmos Ic Ex-Nor Gate] , Ic 4081 [Cmos Ic And Gate] , Ic 4093 [Cmos Ic Nand Gate] , Ic74ls47 [Bcd To 7-Segment Decoder/Driver Ic (7447 Ic) Dip-16 Package] , Lts542 [7-Segment Display - Common Anode] , Lts543 [7-Segment Display - Common Cathode] , Ic Dac0808 [Dac0808 8-Bit Digital To Analog D/A Converter Ic Dip-16 Package] , Ic Adc0809 [Adc0809 8-Bit A/D Converter With 8-Channel Multiplexer Ic Dip-28 Package] , Ic723 [Voltage Regulator Ic Input Voltage Up To 40V Output Voltage Adjustable From 2 To 37V Positive Or Negative Supply Operation Series, Shunt, Switching Or Floating Operation Output Current To 150Ma Without External Pass Transistor Adjustable Current Limiting] , Icl8038 [Function Generator Ic Wide Frequency Range - 0.001Hz To 300Khz Variable Duty Cycle - 2% To 98% High Level Outputs - Ttl To 28V Simultaneous Sine, Square, And Triangle Wave Outputs] , Ad633 [Analog Multiplier Ic 4-Quadrant Multiplication Low Cost, 8-Lead Soic And Pdip Packages Complete—No External Components Required Laser-Trimmed Accuracy And Stability Total Error Within 2% Of Full Scale Differential High Impedance X And Y Inputs High Impedance Unity-Gain Summing Input Laser-Trimmed 10 V Scaling Reference] , Lm566 [Vco Ic Wide Supply Voltage Range: 10V To 24V Very Linear Modulation Characteristics High Temperature Stability Excellent Supply Voltage Rejection 10 To 1 Frequency Range With Fixed Capacitor Frequency Programmable By Means Of Current, Voltage, Resistor Or Capacitor] , Ic Ne555 [Ne555 Timer Ic Dip-8 Package, Pack(Set) Of 30 Ics] , Ic 741 Op-Amp (Dip) [741 Ic - Dip Package - General Purpose Op-Amp Ic, Pack(Set) Of 50 Op-Amps] , Transistor 2N3904 [Pack (Set) Of 20 Transistors] , Transistor Bc107b [Pack (Set) Of 20 Transistors] , Diode 1N4007 [Pack (Set) Of 50 Diodes] , Fet- Bfw10 [Pack (Set) Of 50 Field Effect Transistors] , Zener Diode 5.6V, 1W [Pack (Set) Of 20 Zener Diodes] , Potentiometer 1 K?, 10 K?,100 K? Power Rating: 1W [20 Nos Of Each Value] , Wire Stripping Pliers, 6 Inch Long [Stainless Steel, Rust Resistant.] , Long Nose Mini-Pliers [Stainless Steel, Rust Resistant.] , Resistor 33O, 56O, 68O, 82O, 100O, 120O, 200O, 220O, 270O, 330O, 390O, 470O, 680O, 1K?,1.5K?. Maximium Power Rating 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Resistor 2.2K?, 2.7K?, 3K?, 4.7K?, 5.6K?, 6.8K?, 8.2K?, 10K?, 20K?, 36K?, 56K?, 68K?, 100K?, 470K?, 1M?, 2M? Maximium Power Rating: 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Disk Ceramic Capacitor Of Values 220 Pf, 0.01 ?F, 0.024?F, 0.1?F, 0.24?F [Pack(Set) 25 Nos Of Capacitors For Each Valueh] , Disk Ceramic Capacitor Of Values 10?F(63V), 100?F, 220?F, 470?F(50V) [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Polypropylene Capacitor Of Values 0.001 ?F,0.01 ?F, 0.1 ?F, 0.22 ?F [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Tantalum Capacitor 10 ?F (25 V) [Pack(Set) Of 25 Capacitors] , Incandescent Bulb, 40W, 100W, 200 W [With Tungstenfilament And B22 Connector]
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
West Bengal View Result →
10.
Railways #11139855 AOC
Supply Of supply of split air-conditioner , supply of split air-conditioner of bee 5-star rating, suitable for cooling capacity for the whol e range of 5201 to 6860w (2 ton) with the function of cooling only, with rotary compressor, inverter (varia ble speed) type, suitable for 230v ac, 50 hz system, with 100% copper coil, eco friendly refrigerant, anti- freeze thermostat, with thermal protection for blower motor & condenser motor. conforming to bis specifi cation no. is:1391 (part-2) 2023. bee 5-star rating must comply to ministry of power notification no. s.o. 38 97(e) dated 29th october 2019 for table 3.2(f) with minimum indian seasonal energy efficiency ratio of 5. 0 (applicability date extended by notifications no. s.o. 4485(e) dated 10th december, 2020 and no. s.o. 46 34(e) dated 10th november, 2021). complying to ministry of power notification no. s.o. 2528(e) dated 8th august 2017 for other requirements. refrigerant copper pipes (suction & return) of minimum 4-meter lengt h each, nitrile rubber tube with density 55 kg/cubic meter or more, fire performance class 1, rate of burn ing class v-0, water vapour diffusion resistance factor more than 12000, service temperature 10 to 105-de gree c, surface flame spread class 1 & thickness of minimum inch, relevant test certificates to be submitte d. nitrile rubber tube shall be with suitable inner diameter to suit & to wrap the complete length of refriger ant copper pipe and aluminium foil lamination of 0.2 mm thick to cover entire length of the copper refriger ant pipes, outdoor unit stand and spare pcb circuit will be supplied along with each air-conditioner. any in dian is make - blue star ,lloyd, godrej ,carrier ,daikin voltas etc. detailed specifications attached as annex ure-a. [ warranty period: 12 months after the date of delivery ] ]
Contract Date: May 22, 2026 Contract Value : 3.19 Lakh
Government Departments No of Bidders 1
West Bengal View Result →
11.
Power #11105803 Technical Bid
Tender For Universal Remote Kit Including Thermostat And Pcb For 1.5 Tr Window Ac , Universal Remote Kit Including Thermostat And Pcb For 1.5 Tr Split Ac , Fan Motor For Condensing Unit Without Fan Blade (Outdoor Unit) Model-Lm200lk 4038, Capacitor 10 Mfd.,1Ph, 450 W 1330 Rpm Make-Godrej , Ac Coil Cleaning Liquid C-Shine Or Equivalent , Fan Motor For Lg Make Window Ac 1.5 Ton, 29Kge775t, 220Volt, 1.25 Amp, 880 Rpm, 50 Hz, 1 Phase, 149 Volt, Capacity 10.0/370 Volt, Cpn-H102-00311G, Cu Winding , Fan Motor For Voltas Make Window Ac 1.5 Ton, 230 V, 50 Hz,1 Ph.,1/7Hp, Rpm 915/890/865,Cap. 6.0/440V, Model 29Sahg058, Marathon/Ge Or Equivalent, Cu Winding , Dryers Size 5/8* 5/8 Flare 6 Long Danfoss/Catch All/Dry All , 3-Phase Ac Contactors, Coil Voltage- 220 V Current Rating :- 32 Annual Periodical Maintenance , Copper Elbow Size 1-1/8 , Capillary Tube 0.60 , Heavy Duty Copper Tube 1/4 , Insulation Sleeve 1/4 For Ac , Condenser Fan Motor, Make Ge India Limited Or Equivalent, 1 Phase, 1.5 A, 1/5 Hp, 149 Watts , 920 Rpm, Class- B Insulation, Cu Winding. , Brazing Rod , Cu Elbow Size 3/8 , Supply Lead 3 Core 2.5 Mm2 With Earth Wire Of Make Repair Renovation Kabel/Polycab/Havells /Finolex /Kei , Running Capacitor 6Mfd (Keltron/Epcos) , Dual Run Capacitor 50X4 Mfd (Keltron/ Epcos) , Running Capacitor 4Mfd (Keltron/Epcos) , Starting Capacitor 80/100Mfd (Keltron/Epcos) , Thermally Protected Scroll Compressor Unit Of Capacity 7.5Tr Voltage-415V, 3 Phase, 50 Hz, Make Voltas /Kirloskar/ Copeland , Cooling Coil For 11Tr Package Ac Unit Model 1108, As Per Attached Sketch ‘A , Rotary Compressor For 1.5 Ton Lg Make Window Ac, 1 Phase, 50Hz, 220-240V,R-22 Gas Make: Lg/Highly/Hitachi/ Carrier , Rotary Compressor For 1.5 Ton Lg Make Split Ac Model 5Cw2af5 Make: Lg/Highly/Hitachi/ Carrier , Sealed Compressor 1.5Tr, 3 Phase,415V, Kch 522 Hae For Hydrogen Drier , Compressor Model Kce 461 Hae For 80/120 Ltr. Water Coolers Emerson Copeland Make , Fan Motor Along With Base Without Fan Brg. Type, Self-Lubricated. 1/34Hp, 230V,1 Phase, 50 Hz, 940 Rpm,Ge/Marathon Make For Water Coolers. , Epcos Make Dual Run Capacitor 55+6 Mfd +5%,440 Vac,50/60Hz For 1.5 Tr Window Ac , Outdoor Fan Motor For Split Ac 1.5 Tr Lg Make , Flair Nut Brass Pin Valve ½ , Epcos Make Dual Run Capacitor 50+10 Mfd +5%,440 Vac,50/60Hz For 1.5 Tr Window Ac , Straight Thimble For Window Ac Size 4Mm Heavy Duty Copper (1Pkt=100 Nos.) , Angular Thimble For Window Ac Size 4Mm Heavy Duty Copper (1Pkt=100 Nos.) , Copper Elbow Size 1-1/2 , Copper Pipe 1-1/2 , Running Capacitor 10 Mfd (Tecumesh Keltron/Epcos) , Refrigerant Gas Drier 3/8 L5 Dn-50 , Over Load Protector For Kce 461 , Lg Condenser Split Ac 2.0 Tr , Capillary Tube 0.50 , Wall Hanging Thermometer Measuring Temperature 10-50 Degrees With Marking On Glass Stem. , Contactor With Over Load Relay 7 To 16 A For 2.5 Tr Compressor , Starting Relay For Compressor Model Special Repair 1012 , Rotary Compressor For 2.0 Ton Lg Make Window Ac, 1 Phase, 50Hz, 220-240V,R-22 Gas, Make: Lg/Highly/Hitachi/Carrier , Box Type Relay For Ac/Water Coolers For 1.0 To 2.0 Ton. , Split Ac Indoor Unit Of Voltas Make Of Model 2.0T Voltas 245 Dy, R-22 Having Idu Code 4551692. , Split Ac Copper Condenser Of 2Tr Compatible To Model Voltas 245 Dy. , Split Ac Rotary Compressor Of 2Tr Of Ac Model 2.0T Voltas 245 Dy, R-22. Compressor Model No. Ph340g2c-7Mul, 230V, 50 Hz , Voltas 2Tr Split Ac Of Model Voltas 245 Dy Outdoor Fan Motor E-157 V-230, Hz-50, A 0.75, Rpm 850, Phase-1, Watt-93, Hp-1/8 Class-B Insulation, Cu Winding. , Condenser For Compressor Model Kce 443 Hae For 60/80 Ltr. Water Coolers , Condenser For Compressor Model Kce 461 Hae For 80/120 Ltr. Water Coolers , Universal Remote Kit Including Thermostat And Pcb For 1.5 Tr Window Ac , Universal Remote Kit Including Thermostat And Pcb For 1.5 Tr Split Ac , Fan Motor For Condensing Unit Without Fan Blade (Outdoor Unit) Model-Lm200lk 4038, Capacitor 10 Mfd.,1Ph, 450 W 1330 Rpm Make-Godrej , Ac Coil Cleaning Liquid C-Shine Or Equivalent , Fan Motor For Lg Make Window Ac 1.5 Ton, 29Kge775t, 220Volt, 1.25 Amp, 880 Rpm, 50 Hz, 1 Phase, 149 Volt, Capacity 10.0/370 Volt, Cpn-H102-00311G, Cu Winding , Fan Motor For Voltas Make Window Ac 1.5 Ton, 230 V, 50 Hz,1 Ph.,1/7Hp, Rpm 915/890/865,Cap. 6.0/440V, Model 29Sahg058, Marathon/Ge Or Equivalent, Cu Winding , Dryers Size 5/8* 5/8 Flare 6 Long Danfoss/Catch All/Dry All , 3-Phase Ac Contactors, Coil Voltage- 220 V Current Rating :- 32 Annual Periodical Maintenance , Copper Elbow Size 1-1/8 , Capillary Tube 0.60 , Heavy Duty Copper Tube 1/4 , Insulation Sleeve 1/4 For Ac , Condenser Fan Motor, Make Ge India Limited Or Equivalent, 1 Phase, 1.5 A, 1/5 Hp, 149 Watts , 920 Rpm, Class- B Insulation, Cu Winding. , Brazing Rod , Cu Elbow Size 3/8 , Supply Lead 3 Core 2.5 Mm2 With Earth Wire Of Make Repair Renovation Kabel/Polycab/Havells /Finolex /Kei , Running Capacitor 6Mfd (Keltron/Epcos) , Dual Run Capacitor 50X4 Mfd (Keltron/ Epcos) , Running Capacitor 4Mfd (Keltron/Epcos) , Starting Capacitor 80/100Mfd (Keltron/Epcos) , Thermally Protected Scroll Compressor Unit Of Capacity 7.5Tr Voltage-415V, 3 Phase, 50 Hz, Make Voltas /Kirloskar/ Copeland , Cooling Coil For 11Tr Package Ac Unit Model 1108, As Per Attached Sketch ‘A , Rotary Compressor For 1.5 Ton Lg Make Window Ac, 1 Phase, 50Hz, 220-240V,R-22 Gas Make: Lg/Highly/Hitachi/ Carrier , Rotary Compressor For 1.5 Ton Lg Make Split Ac Model 5Cw2af5 Make: Lg/Highly/Hitachi/ Carrier , Sealed Compressor 1.5Tr, 3 Phase,415V, Kch 522 Hae For Hydrogen Drier , Compressor Model Kce 461 Hae For 80/120 Ltr. Water Coolers Emerson Copeland Make , Fan Motor Along With Base Without Fan Brg. Type, Self-Lubricated. 1/34Hp, 230V,1 Phase, 50 Hz, 940 Rpm,Ge/Marathon Make For Water Coolers. , Epcos Make Dual Run Capacitor 55+6 Mfd +5%,440 Vac,50/60Hz For 1.5 Tr Window Ac , Outdoor Fan Motor For Split Ac 1.5 Tr Lg Make , Flair Nut Brass Pin Valve ½ , Epcos Make Dual Run Capacitor 50+10 Mfd +5%,440 Vac,50/60Hz For 1.5 Tr Window Ac , Straight Thimble For Window Ac Size 4Mm Heavy Duty Copper (1Pkt=100 Nos.) , Angular Thimble For Window Ac Size 4Mm Heavy Duty Copper (1Pkt=100 Nos.) , Copper Elbow Size 1-1/2 , Copper Pipe 1-1/2 , Running Capacitor 10 Mfd (Tecumesh Keltron/Epcos) , Refrigerant Gas Drier 3/8 L5 Dn-50 , Over Load Protector For Kce 461 , Lg Condenser Split Ac 2.0 Tr , Capillary Tube 0.50 , Wall Hanging Thermometer Measuring Temperature 10-50 Degrees With Marking On Glass Stem. , Contactor With Over Load Relay 7 To 16 A For 2.5 Tr Compressor , Starting Relay For Compressor Model Special Repair 1012 , Rotary Compressor For 2.0 Ton Lg Make Window Ac, 1 Phase, 50Hz, 220-240V,R-22 Gas, Make: Lg/Highly/Hitachi/Carrier , Box Type Relay For Ac/Water Coolers For 1.0 To 2.0 Ton. , Split Ac Indoor Unit Of Voltas Make Of Model 2.0T Voltas 245 Dy, R-22 Having Idu Code 4551692. , Split Ac Copper Condenser Of 2Tr Compatible To Model Voltas 245 Dy. , Split Ac Rotary Compressor Of 2Tr Of Ac Model 2.0T Voltas 245 Dy, R-22. Compressor Model No. Ph340g2c-7Mul, 230V, 50 Hz , Voltas 2Tr Split Ac Of Model Voltas 245 Dy Outdoor Fan Motor E-157 V-230, Hz-50, A 0.75, Rpm 850, Phase-1, Watt-93, Hp-1/8 Class-B Insulation, Cu Winding. , Condenser For Compressor Model Kce 443 Hae For 60/80 Ltr. Water Coolers , Condenser For Compressor Model Kce 461 Hae For 80/120 Ltr. Water Coolers
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
12.
Rural Development #11105174 Technical Bid
Tender for Provide Electric Material At V.P. Chouk Tal Khalapur Dist Raigad , Lehar Led 22 Vat , Lehar Led 18 Vat , Syska Led 22 Vat , Syska Led 18 Vat , Philips Led 22 Vat , Philips Led 18 Vat , Syska Led 22 Vat With Sensor , Syska Led 18 Vat With Sensor , Ftape , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led Tube 14 Vat With Chock , Electric Tester (Taparia Co.) , Tripple 40 Ampier , Pannel Board With All Fitting , D.P Switch 32 A , Single Phase Pivantar , Polycab 1.5 Mm Wire , Polycab 2.0 Mm Wire , Cutout Three Phase , Service Wire Aluminium 6 Core , Service Wire Aluminium 8 Core , Service Wire Aluminium 12 Core , Service Cable 3 Phase Coper , Service Cable 4 Phase Coper , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Tripple 32 Ampier , Starter For 3 Hp Pump (Lnt Crompton) , Starter For 5 Hp Pump (Lnt Crompton) , Starter For 15 Hp Pump (Lnt Crompton) , Street Lite Set Led 50 Wat With All Fitting , Pipe For Cement Poll With Clamp, Nut Bolt, Pipe , Pipe For Iron Poll With Clamp, Nut Bolt, Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb 60 Vat Philips , Street Lite Set Led, 50 Wat With All Fitting (Micronic Co.) , Street Lite Set Led, 70 Wat With All Fitting (Micronic Co.) , Street Lite Set Led, 100 Wat With All Fitting (Micronic Co.) , Street Lite Set Led, 50 Wat With All Fitting (Syska Co.) , Street Lite Set Led, 70 Wat With All Fitting (Syska Co.) , Street Lite Set Led, 100 Wat With All Fitting (Syska Co.) , Street Lite Set Led, 50 Wat With All Fitting (Philips) , Street Lite Set Led, 70 Wat With All Fitting (Philips) , Street Lite Set Led, 100 Wat With All Fitting (Philips) , Solar Led Streetlight 50 Wat With All Fitting (Syska Co.) , Solar Led Streetlight 70 Wat With All Fitting (Syska Co.) , Solar Led Streetlight 100 Wat With All Fitting (Syska Co.) , Solar Led Streetlight 50 Wat With All Fitting (Philips Co.) , Solar Led Streetlight 70 Wat With All Fitting (Philips Co.) , Solar Led Streetlight 100 Wat With All Fitting (Philips Co.) , Four Phase Cable Wire , One Phase Fitting Wire , Electric Celling Fan (Cromton) , Electric Celling Fan (Havells) , Led Bulb Syska 24Wt , Led Bulb Syska 18Wt , Control Panal 32 annual periodical maintenance , Control Panal 63 annual periodical maintenance , Cfl Bulb 75 Vat (Ajenta) , Cfl Bulb 75 Vat (Crompton) , Screw , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Inverter Luminous 1500 Va (With All Fitting Including Exide Battery) , Inverter Luminous 2000 Va (With All Fitting Including Exide Battery) , Inverter Luminous 2500 Va (With All Fitting Including Exide Battery) , Mccb (Lt) 10Amp , Mccb (Lt) 16Amp , Mccb (Lt) 28Amp , Mccb (Lt) 32Amp , Leg 16 , Leg 18 , Leg 32 , Led Booster (50 Vat) (Micronic Co.) , Led Booster (70 Vat) (Micronic Co.) , Led Booster (50 Vat) (Syska Co.) , Led Booster (70 Vat) (Syska Co.) , Led Booster (50 Vat) (Philips Co.) , Led Booster (70 Vat) (Philips Co.) , Led Stips (50 Vat) (Micronic Co.) , Led Stips (70 Vat) (Micronic Co.) , Led Stips (50 Vat) (Syska Co.) , Led Stips (70 Vat) (Syska Co.) , Led Stips (50 Vat) (Philips Co.) , Led Stips (70 Vat) (Philips Co.) , Air Conditioner (A.C) 1 Ton Carrier (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 1 Ton Blue Star (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 1.5 Ton Blue Star (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 1.5 Ton Carrier (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 2 Ton Blue Star (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 2 Ton Carrier (With Including All Taxes & Service Charges) , Freeze (Samsung) 160 Ltr , Freeze (Samsung) 180 Ltr , Freeze (Lg) 160 Ltr , Freeze (Lg) 180 Ltr , Water Puryfier 12 Ltrs (With Including Taxes & Services) , Elctrical Shagadi Prestige 230Vt , Elctrical Shagadi Prestige 2000Wt , Honda Co. Generator (7 Kva) , Honda Co. Generator (7.5 Kva) , Honda Co. Generator (10 Kva) , Honda Co. Generator (15 Kva) , Honda Co. Generator (20 Kva) , Runmax Co.Generator 13 Kva (Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 15 Kva (Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 20 Kva (Silent Soundproof Power Electric Diesel ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 15 Feet , Aluminium Folding Shidi 20 Feet , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Fan Hook With Nut Bolt , Led Bulb 18 Vatt (Philips) , Led Bulb 24 Vatt (Philips) , Switch Board With 3 Switch 2 Plug , Electric Wire , Fan (Usha Co.) , Fan (Orient Co.) , Three Phase Socket , Button (Anchor Co.) , Button (Havells Co.) , Three Pin Socket , Three Pin , Two Pin , Dril Machine , Electric Bell (Havells Co.) , Electric Bell (Anchor Co.) , Led With Sensor (22 Vatt) , Led With Sensor (24 Vatt) , Air Conditioner (A.C) 1 Tone , Air Conditioner (A.C) 1 Tone , Air Conditioner (A.C) 1.5 Tone , Air Conditioner (A.C) 1.5 Tone , Air Conditioner (A.C) 2 Tone , Air Conditioner (A.C) 2 Tone , Freeze (Samsung ) 160Ltr , Freeze (Samsung ) 180Ltr , Freeze (Lg) 160Ltr , Freeze (Lg ) 180Ltr , Polycab Wire 1Mm , Polycab Wire 1.5Mm , Polycab Wire 2.5Mm , Polycab Wire 4Mm , Kessing Electric Patti1/2 , Kessing Electric Patti 3/4 , Kessing Electric Patti 1 , Electric Black Pipe 1/2 , Electric Black Pipe 3/4 , Electric Flexibale Pipe , Tapariya Testar , Tapariy Pakkd , Tariya Srew Driver , Choke Anchar , Choke Philps , Stater Achor , Service Wire Bundle 2.5Mm , Service Wire Bundle 4 Mm , Service Wire Bundle 6 Mm , Service Wire Bundle 8 Mm , Service Wire Bundle 10 Mm , Pipe For Cement Poll With Clamperut Bold , Pipe For Lron Poll With Clam Mut Bold , Four Phase Filling Wire , C.F.L Buld 23 Valt , C.F.L Buld 27 Valt , C.F.L Buld 45 Valt , C.F.L Buld 65 Valt , C.F.L Buld 75 Valt , M.C.C.B 10 annual periodical maintenance Anchor , M.C.C.B 16 annual periodical maintenance Anchor , M.C.C.B 32 annual periodical maintenance Anchor , Eectric Cut Out 63 ˣ415 , Eectric Tube Firture , Holder For C.F.L.65/75/85 Valt , Four Phase Filling Wire , Cut Out Three Phase 63 annual periodical maintenance P415 V , Street Light Fintting P.L.Tube , Street Light Fintting 65 Vat Bult , Meercury Street Light 125M.But , Subrseal Cable 3 Core Heavy Cable Wire For Moatare , 65 Wat Led Light , Bracket For Led Light Philip , Stright Light Cover , Swicg Bord , Pump Cable , Ac Cabale , 1.5 Core Cable , 2.5 Core Cable , Handcglose , Elictric Pole Zula , Melmate , Flexible Cable , Straith Light 36W , Straith Light 50W , Flood Light 100W , Led Bulb 26W , Led Bulb 15W , Aluminiam Bulb Cap , Led Bulb 22W , 4 Pole Mcb 63Amp , Tube Light 20W , Tube Light 36W , Electric Straith Pipe , Pannel Light 12Mm , Pannel Light18mm , Sensor , Surya Straith Light 50W , Surya Straith Light 72W , Panasonic Straith Light 50W , Panasonic Straith Light 72W , Flood Light 50W , Led Bulb 9W , Led Bulb 12W , Led Bulb 18W , Led Bulb 23W , Led Bulb 30W , Submarcial Wire 2.5Mm * 3Core , Fle Wire 2.5Mm * 3Core , 6Amp Switch , 6Amp Socket , 16Amp Switch , 16Amp Socket , Surya Flood Light 100W , 3 Pin Top 16Amp , 3 Pin Top 6Amp
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
14.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
15.
Railways #10970976 AOC
Supply Of Supply Of Split Air-Conditioner Of Bee 5 Starsupply Of Split Air-Conditioner Of Bee 5 Star,Supply Of Split Air-Conditioner Of Bee 5-Star Rating, Suitable For Cooling Capacity For The Whol E Range Of 5201 To 6860W (2 Ton) With The Function Of Cooling Only, With Rotary Compressor, Inverter (Variable Speed) Type, Suitable For 230V Ac, 50 Hz System, With 100% Copper Coil, Eco Friendly Refrigerant , Anti-Freeze Thermostat, With Thermal Protection For Blower Motor & Condenser Motor. Conforming To Bis S Pecification No. Is:1391 (Part-2) 2023. Bee 5-Star Rating Must Comply To Ministry Of Power Notification No. S. O. 3897(E) Dated 29Th October 2019 For Table 3.2(F) With Minimum Indian Seasonal Energy Efficiency Ratio Of 5.0 (Applicability Date Extended By Notifications No. S.O. 4485(E) Dated 10Th December, 2020 And No. S. O. 4634(E) Dated 10Th November, 2021). Complying To Ministry Of Power Notification No. S.O. 2528(E) Date D 8Th August 2017 For Other Requirements. Refrigerant Copper Pipes (Suction & Return) Of Minimum 4-Meter Length Each, Nitrile Rubber Tube With Density 55 Kg/Cubic Meter Or More, Fire Performance Class 1, Rate Of Burning Class V-0, Water Vapour Diffusion Resistance Factor More Than 12000, Service Temperature 10 To 10 5-Degree C, Surface Flame Spread Class 1 & Thickness Of Minimum Inch, Relevant Test Certificates To Be Sub Mitted. Nitrile Rubber Tube Shall Be With Suitable Inner Diameter To Suit & To Wrap The Complete Length Of Re Frigerant Copper Pipe And Aluminium Foil Lamination Of 0.2 Mm Thick To Cover Entire Length Of The Copper Ref Rigerant Pipes, Outdoor Unit Stand And Spare Pcb Circuit Will Be Supplied Along With Each Air-Conditioner. A Ny Indian Is Make - Blue Star ,Lloyd, Godrej ,Carrier ,Daikin Voltas Etc. [ Warranty Period: 12 Months Afte R The Date Of Delivery ] ]
Contract Date: May 05, 2026 Contract Value : 6.19 Lakh
Government Departments No of Bidders 1
West Bengal View Result →
17.
Communications and Information Technology  #10914488 AOC
Bids Are invited for Supply 3Tr Ductable Inverter Split Ac - Supply Of Ductable Type Ceiling Wall Mounting Type 3 Tr Capacity Inverter Type Split Air Conditioner Unit With Rotary Scroll Type Compressor Suitable For Working On 415V 3Phase 230V 1 Ph 50Hz Ac Supply And Shall Have A Nominal Cooling Capacity Not Less Than 36000 Btu Per Hr With Minimum Eer 10 Btuper W Hr And Having Static Pressure Not Less Than 45 Pascals And The Ac Unit With Pre Charged Eco Friendly R410a Or Equivalent Refrigerant Gas. The Evaporator Indoor Condenser Out Door Coils Shall Have Copper Refrigerant Tubes Pipes Only Including Supply And Fixing Of Powder Coated Air Deflection Grill Of Suitable Gauge Ms Sheet For Closure Of The Above Ac Units Supply Air Portion Including Necessary Associated Items As Required And Including Ac Unit Transportation To Sites At Various Location Under Karnataka Telecom Circle With Loading And Unloading Toppingup Of Refrigerant Gas If Necessary As Required. The Unit Shall Have 12 Months Manufacturers Suppliers Warranty Including For Pcb Board. The Warranty For Compressor Shall Be Minimum 3 Years Make Of Ac Carrier Daikin Hitachi Ogeneral Blue Star Voltas Mitsubishi Electric India Mitsubishi Heavy Industries Panasonic Lg Samsung Sidwal. Separate Agreement Will Be Formed Site Wise By The Executive Engineer Elec Concerned , Itc 3Tr Ductable Inverter Split Ac - Installation Testing And Commissioning The Above 3 Tr Ductable Type Ac Unit Complete With All Accessories Including Installation Of Outdoor Unit On Suitable Ms Angle Framework Made Up Of 35Mmx35mmx5mm Ms Angle Atleast 600Mm Above Floor Level Fixing Of Indoor Unit On The Wall With Suitable Ms Rod Angle Iron Support Including Welding Cutting Painting Of Stands Minor Civil Works Complete Etc As Required. , Refrigerant Copper Piping For Liquid Line - Supplying And Laying Of Following Size Copper Refrigerant Pipe For 3Tr Inverter Type Ductable Split Ac Units As Per Manufacturers Recommendation Suitable For Above Units
Contract Date: Ref. Documents Contract Value : 12.93 Lakh
Government Departments No of Bidders 4
19.
Rural Development #10827344 Price Bid
Providing Electrical Material At Grampanchayat Vadgaon Tal Khalapur Dist Raigad , supply elecric material , lehar led 22 vat , lehar led 18 vat , syska led 22 vat , syska led 18 vat , philips led 22 vat , philips led 18 vat , syska led 22 vat with sensor , syska led 18 vat with sensor , philips led 22 vat with sensor , philips led 18 vat with sensor , syska led tube 14 vat with chock , philips led tube 14 vat with chock , electric tester ( taparia co . ) , tripple 40 ampier , pannel board with all fitting , d . p switch 32 a , single phase pivantar , cutout three phase , service wire aluminium 6 core , service wire aluminium 8 core , service wire aluminium 12 core , service cable 3 phase coper , service cable 4 phase coper , holder for simple bulb , tape bundle , tripple 18 ampier , tripple 32 ampier , starter for 3 hp pump ( lnt crompton ) , starter for 5 hp pump ( lnt crompton ) , starter for 15 hp pump ( lnt crompton ) , street lite set led 50 wat with all fitting , pipe for cement poll with clamp , nut bolt , pipe , pipe for iron poll with clamp , nut bolt , pipe , capacitor for fan , main switch icdp , simple bulb 60 vat philips , street lite set led , 50 wat with all fitting ( micronic co . ) , street lite set led , 70 wat with all fitting ( micronic co . ) , street lite set led , 50 wat with all fitting ( syska co . ) , street lite set led , 70 wat with all fitting ( syska co . ) , street lite set led , 50 wat with all fitting ( philips ) , street lite set led , 70 wat with all fitting ( philips ) , four phase cable wire , one phase fitting wire , electric celling fan ( cromton ) , electric celling fan ( havells ) , led bulb syska 24wt , led bulb syska 18wt , control panal 32 amp , control panal 63 amp , cfl bulb 75 vat ( ajenta ) , cfl bulb 75 vat ( crompton ) , screw , electric tube 4 ft fixtures with all fitting , electric cut out , inverter luminous 1500 va ( with all fitting including exide battery ) , inverter luminous 2000 va ( with all fitting including exide battery ) , inverter luminous 2500 va ( with all fitting including exide battery ) , mccb ( lt ) 10amp , mccb ( lt ) 16amp , mccb ( lt ) 28amp , mccb ( lt ) 32amp , leg 16 , leg 18 , leg 32 , led booster ( 50 vat ) ( micronic co . ) , led booster ( 70 vat ) ( micronic co . ) , led booster ( 50 vat ) ( syska co . ) , led booster ( 70 vat ) ( syska co . ) , led booster ( 50 vat ) ( philips co . ) , led booster ( 70 vat ) ( philips co . ) , led stips ( 50 vat ) ( micronic co . ) , led stips ( 70 vat ) ( micronic co . ) , led stips ( 50 vat ) ( syska co . ) , led stips ( 70 vat ) ( syska co . ) , led stips ( 50 vat ) ( philips co . ) , led stips ( 70 vat ) ( philips co . ) , air conditioner ( a . c ) 1 ton carrier ( with including all taxes & service charges ) , air conditioner ( a . c ) 1 ton blue star ( with including all taxes & service charges ) , air conditioner ( a . c ) 1 . 5 ton blue star ( with including all taxes & service charges ) , air conditioner ( a . c ) 1 . 5 ton carrier ( with including all taxes & service charges ) , air conditioner ( a . c ) 2 ton blue star ( with including all taxes & service charges ) , air conditioner ( a . c ) 2 ton carrier ( with including all taxes & service charges ) , freeze ( samsung ) 160 ltr , freeze ( samsung ) 180 ltr , freeze ( lg ) 160 ltr , freeze ( lg ) 180 ltr , water puryfier 12 ltrs ( with including taxes & services ) , elctrical sagadi prestige 230vt , elctrical sagadi prestige 2000wt , honda co . generator ( 7 kva ) , honda co . generator ( 7 . 5 kva ) , honda co . generator ( 10 kva ) , honda co . generator ( 15 kva ) , honda co . generator ( 20 kva ) , runmax co . generator 13 kva ( silent soundproof power electric diesel ) , runmax co . generator 15 kva ( silent soundproof power electric diesel ) , runmax co . generator 20 kva ( silent soundproof power electric diesel ) , electric safety hand gloves , aluminium folding shidi 15 feet , aluminium folding shidi 20 feet , aluminium folding ghoda 15 feet , aluminium folding ghoda 20 feet , 60 vatt led driver , led with pcb , led fitting charges , smd led panel light 22 vatt , fan hook with nut bolt , led bulb 18 vatt ( philips ) , led bulb 24 vatt ( philips ) , switch board with 3 switch 2 plug , electric wire , fan ( usha co . ) , fan ( orient co . ) , three phase socket , button ( anchor co . ) , button ( havells co . ) , three pin socket , three pin , two pin , dril machine , electric bell ( havells co . ) , electric bell ( anchor co . ) , led with sensor ( 22 vatt ) , led with sensor ( 24 vatt )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
20.
Rural Development #10710970 Price Bid
Provide Electrical Material At Grampanchayat Tambati Tal Khalapur Dist Raigad , Supply Elecric Material , Lehar Led 22 Vat , Lehar Led 18 Vat , Syska Led 22 Vat , Syska Led 18 Vat , Philips Led 22 Vat , Philips Led 18 Vat , Syska Led 22 Vat With Sensor , Syska Led 18 Vat With Sensor , Philips Led 22 Vat With Sensor , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led Tube 14 Vat With Chock , Electric Tester ( Taparia Co. ) , Tripple 40 Ampier , Pannel Board With All Fitting , D.P Switch 32 A , Single Phase Pivantar , Polycab 1.5 Mm Wire , Polycab 2.0 Mm Wire , Cutout Three Phase , Service Wire Aluminium 6 Core , Service Wire Aluminium 8 Core , Service Wire Aluminium 12 Core , Service Cable 3 Phase Coper , Service Cable 4 Phase Coper , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Tripple 32 Ampier , Starter For 3 Hp Pump ( Lnt Crompton ) , Starter For 5 Hp Pump ( Lnt Crompton ) , Starter For 15 Hp Pump ( Lnt Crompton ) , Street Lite Set Led 50 Wat With All Fitting , Pipe For Cement Poll Withclamp, Nut Bolt, Pipe , Pipe For Ironpoll Withclamp, Nut Bolt, Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb60 Vat Philips , Street Lite Set Led, 50 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 50 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 50 Wat With All Fitting ( Philips ) , Street Lite Set Led, 70 Wat With All Fitting ( Philips ) , Street Lite Set Led, 100 Wat With All Fitting ( Philips ) , Solar Led Streetlight 50 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 50 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Philips Co. ) , Four Phase Cable Wire , One Phase Fitting Wire , Electric Celling Fan ( Cromton ) , Electric Celling Fan ( Havells ) , Led Bulb Syska 24Wt , Led Bulb Syska 18Wt , Control Panal 32 Amp , Control Panal 63 Amp , Cfl Bulb 75 Vat ( Ajenta ) , Cfl Bulb 75 Vat ( Crompton ) , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Inverter Luminous 1500 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2500 Va ( With All Fitting Including Exide Battery ) , Mccb ( Lt ) 10Amp , Mccb ( Lt ) 16Amp , Mccb ( Lt ) 28Amp , Mccb ( Lt ) 32Amp , Led Booster ( 50 Vat ) ( Micronic Co. ) , Led Booster ( 70 Vat ) ( Micronic Co. ) , Led Booster ( 50 Vat ) ( Syska Co. ) , Led Booster ( 70 Vat ) ( Syska Co. ) , Led Booster ( 50 Vat ) ( Philips Co. ) , Led Booster ( 70 Vat ) ( Philips Co. ) , Led Stips ( 50 Vat ) ( Micronic Co. ) , Led Stips ( 70 Vat ) ( Micronic Co. ) , Led Stips ( 50 Vat ) ( Syska Co. ) , Led Stips ( 70 Vat ) ( Syska Co. ) , Led Stips ( 50 Vat ) ( Philips Co. ) , Led Stips ( 70 Vat ) ( Philips Co. ) , Air Conditioner ( A.C ) 1 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1.5 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1.5 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Carrier ( With Including All Taxes & Service Charges ) , Freeze ( Samsung ) 160 Ltr , Freeze ( Samsung ) 180 Ltr , Freeze ( Lg ) 160 Ltr , Freeze ( Lg ) 180 Ltr , Water Puryfier 12 Ltrs ( With Including Taxes & Services ) , Elctrical Shagadi Prestige 230Vt , Elctrical Shagadi Prestige 2000Wt , Honda Co. Generator ( 7 Kva ) , Honda Co. Generator ( 7.5 Kva ) , Honda Co. Generator ( 10 Kva ) , Honda Co. Generator ( 15 Kva ) , Honda Co. Generator ( 20 Kva ) , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel  ) , Runmax Co.Generator 15 Kva ( Silent Soundproof Power Electric Diesel  ) , Runmax Co.Generator 20 Kva ( Silent Soundproof Power Electric Diesel  ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 15 Feet , Aluminium Folding Shidi 20 Feet , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Fan Hook With Nut Bolt , Led Bulb 18 Vatt ( Philips ) , Led Bulb 24 Vatt ( Philips ) , Switch Board With3 Switch 2 Plug , Electric Wire , Fan ( Usha Co. ) , Fan ( Orient Co. ) , Three Phase Socket , Button ( Anchor Co. ) , Button ( Havells Co. ) , Three Pin Socket , Dril Machine , Electric Bell ( Havells Co. ) , Electric Bell ( Anchor Co. ) , Led With Sensor ( 22 Vatt ) , Led With Sensor ( 24 Vatt ) , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1.5Tone , Air Conditioner ( A.C ) 1.5 Tone , Air Conditioner ( A.C ) 2Tone , Air Conditioner ( A.C ) 2 Tone , Freeze ( Samsung ) 160Ltr , Freeze ( Samsung ) 180Ltr , Freeze ( Lg ) 160Ltr , Freeze ( Lg ) 180Ltr , Polycab Wire 1Mm , Polycab Wire 1.5Mm , Polycab Wire 2.5Mm , Polycabwire 4Mm , Kessing Electric Patti1 / 2 , Kessing Electric Patti 3 / 4 , Kessing Electric Patti 1 , Electric Black Pipe 1 / 2 , Electric Black Pipe 3 / 4 , Electric Flexibale Pipe , Tapariya Testar , Tapariy Pakkd , Tariya Srew Driver , Choke Anchar , Choke Philps , Stater Achor , Service Wire Bundle 2.5Mm , Service Wire Bundle 4 Mm , Service Wire Bundle 6 Mm , Service Wire Bundle 8 Mm , Service Wire Bundle 10 Mm , Pipe For Cement Poll With Clamperut Bold , Pipe For Lron Poll With Clam Mut Bold , Four Phase Filling Wire , C.F.L Buld 23 Valt , C.F.L Buld 27 Valt , C.F.L Buld 45 Valt , C.F.L Buld 65 Valt , C.F.L Buld 75 Valt , M.C.C.B 10 Amp Anchor , M.C.C.B 16 Amp Anchor , M.C.C.B 32 Amp Anchor , Eectric Cut Out 63 ?415 , Eectric Tube Firture , Holder For C.F.L.65 / 75 / 85 Valt , Four Phase Filling Wire , Cut Out Three Phase 63 Amp P415 V , Streetlight Fintting P.L.Tube , Streetlight Fintting 65 Vat Bult , Meercury Street Light 125M.But , Subrseal Cable 3 Core Heavy Cable Wire For Moatare , 65 Wat Led Light , Bracket For Led Light Philip , Stright Light Cover , 1.5 Core Cable , 2.5 Core Cable , Elictric Pole Zula , Flexible Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
21.
Rural Development #10710686 Price Bid
Provide Electrical Material At Grampanchayat Savroli Tal Khalapur Dist Raigad , Supply Elecric Material , Lehar Led 22 Vat , Lehar Led 18 Vat , Syska Led 22 Vat , Syska Led 18 Vat , Philips Led 22 Vat , Philips Led 18 Vat , Syska Led 22 Vat With Sensor , Syska Led 18 Vat With Sensor , Philips Led 22 Vat With Sensor , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led Tube 14 Vat With Chock , Electric Tester (Taparia Co.) , Tripple 40 Ampier , Pannel Board With All Fitting , D.P Switch 32 A , Single Phase Pivantar , Polycab 1.5 Mm Wire , Polycab 2.0 Mm Wire , Cutout Three Phase , Service Wire Aluminium 6 Core , Service Wire Aluminium 8 Core , Service Wire Aluminium 12 Core , Service Cable 3 Phase Coper , Service Cable 4 Phase Coper , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Tripple 32 Ampier , Starter For 3 Hp Pump (Lnt Crompton) , Starter For 5 Hp Pump (Lnt Crompton) , Starter For 15 Hp Pump (Lnt Crompton) , Street Lite Set Led 50 Wat With All Fitting , Pipe For Cement Poll Withclamp, Nut Bolt, Pipe , Pipe For Ironpoll Withclamp, Nut Bolt, Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb60 Vat Philips , Street Lite Set Led, 50 Wat With All Fitting (Micronic Co.) , Street Lite Set Led, 70 Wat With All Fitting (Micronic Co.) , Street Lite Set Led, 100 Wat With All Fitting (Micronic Co.) , Street Lite Set Led, 50 Wat With All Fitting (Syska Co.) , Street Lite Set Led, 70 Wat With All Fitting (Syska Co.) , Street Lite Set Led, 100 Wat With All Fitting (Syska Co.) , Street Lite Set Led, 50 Wat With All Fitting (Philips) , Street Lite Set Led, 70 Wat With All Fitting (Philips) , Street Lite Set Led, 100 Wat With All Fitting (Philips) , Solar Led Streetlight 50 Wat With All Fitting (Syska Co.) , Solar Led Streetlight 70 Wat With All Fitting (Syska Co.) , Solar Led Streetlight 100 Wat With All Fitting (Syska Co.) , Solar Led Streetlight 50 Wat With All Fitting (Philips Co.) , Solar Led Streetlight 70 Wat With All Fitting (Philips Co.) , Solar Led Streetlight 100 Wat With All Fitting (Philips Co.) , Four Phase Cable Wire , One Phase Fitting Wire , Electric Celling Fan (Cromton) , Electric Celling Fan (Havells) , Led Bulb Syska 24Wt , Led Bulb Syska 18Wt , Control Panal 32 Amp , Control Panal 63 Amp , Cfl Bulb 75 Vat (Ajenta) , Cfl Bulb 75 Vat (Crompton) , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Inverter Luminous 1500 Va (With All Fitting Including Exide Battery) , Inverter Luminous 2000 Va (With All Fitting Including Exide Battery) , Inverter Luminous 2500 Va (With All Fitting Including Exide Battery) , Mccb (Lt) 10Amp , Mccb (Lt) 16Amp , Mccb (Lt) 28Amp , Mccb (Lt) 32Amp , Led Booster (50 Vat) (Micronic Co.) , Led Booster (70 Vat) (Micronic Co.) , Led Booster (50 Vat) (Syska Co.) , Led Booster (70 Vat) (Syska Co.) , Led Booster (50 Vat) (Philips Co.) , Led Booster (70 Vat) (Philips Co.) , Led Stips (50 Vat) (Micronic Co.) , Led Stips (70 Vat) (Micronic Co.) , Led Stips (50 Vat) (Syska Co.) , Led Stips (70 Vat) (Syska Co.) , Led Stips (50 Vat) (Philips Co.) , Led Stips (70 Vat) (Philips Co.) , Air Conditioner (A.C) 1 Ton Carrier (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 1 Ton Blue Star (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 1.5 Ton Blue Star (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 1.5 Ton Carrier (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 2 Ton Blue Star (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 2 Ton Carrier (With Including All Taxes & Service Charges) , Freeze (Samsung) 160 Ltr , Freeze (Samsung) 180 Ltr , Freeze (Lg) 160 Ltr , Freeze (Lg) 180 Ltr , Water Puryfier 12 Ltrs (With Including Taxes & Services) , Elctrical Shagadi Prestige 230Vt , Elctrical Shagadi Prestige 2000Wt , Honda Co. Generator(7 Kva) , Honda Co. Generator(7.5 Kva) , Honda Co. Generator(10 Kva) , Honda Co. Generator(15 Kva) , Honda Co. Generator(20 Kva) , Runmax Co.Generator 13 Kva (Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 15 Kva (Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 20 Kva (Silent Soundproof Power Electric Diesel ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 15 Feet , Aluminium Folding Shidi 20 Feet , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Fan Hook With Nut Bolt , Led Bulb 18 Vatt (Philips) , Led Bulb 24 Vatt (Philips) , Switch Board With3 Switch 2 Plug , Electric Wire , Fan (Usha Co.) , Fan (Orient Co.) , Three Phase Socket , Button (Anchor Co.) , Button (Havells Co.) , Three Pin Socket , Dril Machine , Electric Bell (Havells Co.) , Electric Bell (Anchor Co.) , Led With Sensor (22 Vatt) , Led With Sensor (24 Vatt) , Air Conditioner (A.C) 1 Tone , Air Conditioner (A.C) 1 Tone , Air Conditioner (A.C) 1.5Tone , Air Conditioner (A.C) 1.5 Tone , Air Conditioner (A.C) 2Tone , Air Conditioner (A.C) 2 Tone , Freeze (Samsung ) 160Ltr , Freeze (Samsung ) 180Ltr , Freeze (Lg) 160Ltr , Freeze (Lg ) 180Ltr , Polycab Wire 1Mm , Polycab Wire 1.5Mm , Polycab Wire 2.5Mm , Polycabwire 4Mm , Kessing Electric Patti1/2 , Kessing Electric Patti 3/4 , Kessing Electric Patti 1 , Electric Black Pipe 1/2 , Electric Black Pipe 3/4 , Electric Flexibale Pipe , Tapariya Testar , Tapariy Pakkd , Tariya Srew Driver , Choke Anchar , Choke Philps , Stater Achor , Service Wire Bundle 2.5Mm , Service Wire Bundle 4 Mm , Service Wire Bundle 6 Mm , Service Wire Bundle 8 Mm , Service Wire Bundle 10 Mm , Pipe For Cement Poll With Clamperut Bold , Pipe For Lron Poll With Clam Mut Bold , Four Phase Filling Wire , C.F.L Buld 23 Valt , C.F.L Buld 27 Valt , C.F.L Buld 45 Valt , C.F.L Buld 65 Valt , C.F.L Buld 75 Valt , M.C.C.B 10 Amp Anchor , M.C.C.B 16 Amp Anchor , M.C.C.B 32 Amp Anchor , Eectric Cut Out 63 ?415 , Eectric Tube Firture , Holder For C.F.L.65/75/85 Valt , Four Phase Filling Wire , Cut Out Three Phase 63 Amp P415 V , Streetlight Fintting P.L.Tube , Streetlight Fintting 65 Vat Bult , Meercury Street Light 125M.But , Subrseal Cable 3 Core Heavy Cable Wire For Moatare , 65 Wat Led Light , Bracket For Led Light Philip , Stright Light Cover , 1.5 Core Cable , 2.5 Core Cable , Elictric Pole Zula , Flexible Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
22.
Rural Development #10710553 Price Bid
Provide Provide Electrical Material At Grampanchayat Chouk Tal Khalapur Dist Raigad , Supply Elecric Material , Lehar Led 22 Vat , Lehar Led 18 Vat , Syska Led 22 Vat , Syska Led 18 Vat , Philips Led 22 Vat , Philips Led 18 Vat , Syska Led 22 Vat With Sensor , Syska Led 18 Vat With Sensor , Philips Led 22 Vat With Sensor , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led Tube 14 Vat With Chock , Electric Tester ( Taparia Co. ) , Tripple 40 Ampier , Pannel Board With All Fitting , D.P Switch 32 A , Single Phase Pivantar , Polycab 1.5 Mm Wire , Polycab 2.0 Mm Wire , Cutout Three Phase , Service Wire Aluminium 6 Core , Service Wire Aluminium 8 Core , Service Wire Aluminium 12 Core , Service Cable 3 Phase Coper , Service Cable 4 Phase Coper , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Tripple 32 Ampier , Starter For 3 Hp Pump ( Lnt Crompton ) , Starter For 5 Hp Pump ( Lnt Crompton ) , Starter For 15 Hp Pump ( Lnt Crompton ) , Street Lite Set Led 50 Wat With All Fitting , Pipe For Cement Poll Withclamp, Nut Bolt, Pipe , Pipe For Ironpoll Withclamp, Nut Bolt, Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb60 Vat Philips , Street Lite Set Led, 50 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 50 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 50 Wat With All Fitting ( Philips ) , Street Lite Set Led, 70 Wat With All Fitting ( Philips ) , Street Lite Set Led, 100 Wat With All Fitting ( Philips ) , Solar Led Streetlight 50 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 50 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Philips Co. ) , Four Phase Cable Wire , One Phase Fitting Wire , Electric Celling Fan ( Cromton ) , Electric Celling Fan ( Havells ) , Led Bulb Syska 24Wt , Led Bulb Syska 18Wt , Control Panal 32 Amp , Control Panal 63 Amp , Cfl Bulb 75 Vat ( Ajenta ) , Cfl Bulb 75 Vat ( Crompton ) , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Inverter Luminous 1500 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2500 Va ( With All Fitting Including Exide Battery ) , Mccb ( Lt ) 10Amp , Mccb ( Lt ) 16Amp , Mccb ( Lt ) 28Amp , Mccb ( Lt ) 32Amp , Led Booster ( 50 Vat ) ( Micronic Co. ) , Led Booster ( 70 Vat ) ( Micronic Co. ) , Led Booster ( 50 Vat ) ( Syska Co. ) , Led Booster ( 70 Vat ) ( Syska Co. ) , Led Booster ( 50 Vat ) ( Philips Co. ) , Led Booster ( 70 Vat ) ( Philips Co. ) , Led Stips ( 50 Vat ) ( Micronic Co. ) , Led Stips ( 70 Vat ) ( Micronic Co. ) , Led Stips ( 50 Vat ) ( Syska Co. ) , Led Stips ( 70 Vat ) ( Syska Co. ) , Led Stips ( 50 Vat ) ( Philips Co. ) , Led Stips ( 70 Vat ) ( Philips Co. ) , Air Conditioner ( A.C ) 1 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1.5 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1.5 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Carrier ( With Including All Taxes & Service Charges ) , Freeze ( Samsung ) 160 Ltr , Freeze ( Samsung ) 180 Ltr , Freeze ( Lg ) 160 Ltr , Freeze ( Lg ) 180 Ltr , Water Puryfier 12 Ltrs ( With Including Taxes & Services ) , Elctrical Shagadi Prestige 230Vt , Elctrical Shagadi Prestige 2000Wt , Honda Co. Generator ( 7 Kva ) , Honda Co. Generator ( 7.5 Kva ) , Honda Co. Generator ( 10 Kva ) , Honda Co. Generator ( 15 Kva ) , Honda Co. Generator ( 20 Kva ) , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel  ) , Runmax Co.Generator 15 Kva ( Silent Soundproof Power Electric Diesel  ) , Runmax Co.Generator 20 Kva ( Silent Soundproof Power Electric Diesel  ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 15 Feet , Aluminium Folding Shidi 20 Feet , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Fan Hook With Nut Bolt , Led Bulb 18 Vatt ( Philips ) , Led Bulb 24 Vatt ( Philips ) , Switch Board With3 Switch 2 Plug , Electric Wire , Fan ( Usha Co. ) , Fan ( Orient Co. ) , Three Phase Socket , Button ( Anchor Co. ) , Button ( Havells Co. ) , Three Pin Socket , Dril Machine , Electric Bell ( Havells Co. ) , Electric Bell ( Anchor Co. ) , Led With Sensor ( 22 Vatt ) , Led With Sensor ( 24 Vatt ) , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1.5Tone , Air Conditioner ( A.C ) 1.5 Tone , Air Conditioner ( A.C ) 2Tone , Air Conditioner ( A.C ) 2 Tone , Freeze ( Samsung ) 160Ltr , Freeze ( Samsung ) 180Ltr , Freeze ( Lg ) 160Ltr , Freeze ( Lg ) 180Ltr , Polycab Wire 1Mm , Polycab Wire 1.5Mm , Polycab Wire 2.5Mm , Polycabwire 4Mm , Kessing Electric Patti1 / 2 , Kessing Electric Patti 3 / 4 , Kessing Electric Patti 1 , Electric Black Pipe 1 / 2 , Electric Black Pipe 3 / 4 , Electric Flexibale Pipe , Tapariya Testar , Tapariy Pakkd , Tariya Srew Driver , Choke Anchar , Choke Philps , Stater Achor , Service Wire Bundle 2.5Mm , Service Wire Bundle 4 Mm , Service Wire Bundle 6 Mm , Service Wire Bundle 8 Mm , Service Wire Bundle 10 Mm , Pipe For Cement Poll With Clamperut Bold , Pipe For Lron Poll With Clam Mut Bold , Four Phase Filling Wire , C.F.L Buld 23 Valt , C.F.L Buld 27 Valt , C.F.L Buld 45 Valt , C.F.L Buld 65 Valt , C.F.L Buld 75 Valt , M.C.C.B 10 Amp Anchor , M.C.C.B 16 Amp Anchor , M.C.C.B 32 Amp Anchor , Eectric Cut Out 63 ?415 , Eectric Tube Firture , Holder For C.F.L.65 / 75 / 85 Valt , Four Phase Filling Wire , Cut Out Three Phase 63 Amp P415 V , Streetlight Fintting P.L.Tube , Streetlight Fintting 65 Vat Bult , Meercury Street Light 125M.But , Subrseal Cable 3 Core Heavy Cable Wire For Moatare , 65 Wat Led Light , Bracket For Led Light Philip , Stright Light Cover , 1.5 Core Cable , 2.5 Core Cable , Elictric Pole Zula , Flexible Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
23.
Defence #10671525 Price Bid
Supply Of Operational Work Stores - 1.01 Ignition Coil For Honda Genr Set 3 Kva 1.02 Self Starter Assy For Honda Genr Set 3 Kva 1.03 Single Element Pump For Kirloskar Genr Set 3.5 Kva 1.04 Cylinder Head Gasket For Kirloskar Genr Set 3.5 Kva 1.05 Piston Ring Set For Kirloskar Genr Set 3.5 Kva 1.06 Avr For Koel Genr Set 3.5 Kva 1.07 Single Element Fuel Pump For Tmtl Eicher Genr Set 5 Kva 1.08 Self Starter Assy For Tmtl Eicher Genr Set 5 Kva 1.09 Fuel Feed Pump For Tmtl Eicher Genr Set 5 Kva 1.1 Injector Assy For Tmtl Eicher Genr Set 5 Kva 1.11 Delivery Holder For Kirloskar Genr Set 5 Kva 1.12 Armature For Kirloskar Genr Set 7.5 Kva 1.13 Field Coil For Kirloskar Genr Set 7.5 Kva 1.14 Fuel Feed Pump For Greaves Genr Set 7.5 Kva 1.15 Injector Assy For Greaves Genr Set 7.5 Kva 1.16 Transformer For Greaves Genr Set 7.5 Kva 1.17 Self Starter Assy For Greaves Genr Set 7.5 Kva 1.18 Pump Element For Greaves Genr Set 7.5 Kva 1.19 Alternator For Greaves Genr Set 7.5 Kva 1.2 Bty 12 Volt 105 Ah For Kirloskar Genr Set 10 Kva 1.21 Self Starter Assy For Kirloskar Genr Set 10 Kva 1.22 Piston Assy For Kirloskar Genr Set 10 Kva 1.23 Panel Board For Kirloskar Genr Set 10 Kva 1.24 Piston Ring Set For Kirloskar Genr Set 10 Kva 1.25 Head Gasket For Greaves Genr Set 12.5 Kva 1.26 Piston Ring Set For Greaves Genr Set 12.5 Kva 1.27 Self Starter For Eicher Genr Set 15 Kva 1.28 Stopper Solenoid For Ashokleyland Genr Set 15 Kva 1.29 Digital Display Control Unit For Ashokleyland Genr Set 15 Kva 1.3 Self Starter Pinion For Ashokleyland Genr Set 15 Kva 1.31 Armature Assy For Kirloskar Gener Set 20 Kva 1.32 Turbo Charger Assy For Kirloskar Gener Set 20 Kva 1.33 Single Element Fuel Pump For Kirloskar Gener Set 20 Kva 1.34 Self Starter Assy For Kirloskar Gener Set 20 Kva 1.35 Alternator Assy For Kirloskar Gener Set 20 Kva 1.36 Complete Gasket Set For Kirloskar Gener Set 20 Kva 1.37 Oil Seal For Kirloskar Gener Set 20 Kva 1.38 Piston Ring Set For Kirloskar Gener Set 20 Kva 1.39 Exhaust Fan For Kirloskar Gener Set 20 Kva 1.4 Fan Belt For Kirloskar Gener Set 20 Kva 1.41 Bty 12 Volt 130 Ah For Kirloskar Genr Set 20 Kva 1.42 Panel Boad For Kirloskar Gener Set 20 Kva 1.43 Avr For Ashokleyland Genr Set 20 Kva 1.44 Complet Gasket Set For Crompton Greaves Genr Set 25 Kva 1.45 Oil Seal Set For Crompton Greaves Genr Set 25 Kva 1.46 Armature For Kirloskar Genr Set 25 Kva 1.47 Field Coil For Kirloskar Genr Set 25 Kva 1.48 Solenoid Sw For Kirloskar Genr Set 25 Kva 1.49 Carbon Brush For Kirloskar Genr Set 25 Kva 1.5 Bush Carrier Plate For Kirloskar Genr Set 25 Kva 1.51 Drive Pinion For Kirloskar Genr Set 25 Kva 1.52 Armature For Kirloskar Genr Set 30 Kva 1.53 Self Starter Assy For Kirloskar Green Genr Set 30 Kva 1.54 Piston Assy For Kirloskar Green Genr Set 30 Kva 1.55 Field Coil For Kirloskar Green Genr Set 30 Kva 1.56 Fuel Feed Pump For Kirloskar Genr Set 30 Kva 1.57 Fuel Filter For Kirloskar Genr Set 30 Kva 1.58 Oil Filetr For Kirloskar Genr Set 30 Kva 1.59 Head Gasket For Kirloskar Genr Set 30 Kva 1.6 Oil Seal ( Both End Of Crank Shaft ) For Kirloskar Genr Set 30 Kva 1.61 Cylinder Head Assy For Kirloskar Genr Set 30 Kva 1.62 Rotary Pump Assy For Kirloskar Genr Set 30 Kva 1.63 Pcb Relay For Kirloskar Genr Set 30 Kva 1.64 Turbocharger For Kirloskar Genr Set 30 Kva 1.65 Piston Ring Set For Kirloskar Genr Set 30 Kva 1.66 Gasket Set For Kirloskar Genr Set 30 Kva 1.67 Exhaust Fan For Kirloskar Gener Set 40 Kva 1.68 Fan Belt For Kirloskar Gener Set 40 Kva 1.69 Fip For Eicher Genr Set 5 Kva 1.7 Fuel Feed Pump For Eicher Genr Set 5 Kva 1.71 Self Starter For Eicher Genr Set 5 Kva 1.72 Injector Set For Eicher Genr Set 5 Kva 1.73 Air Cleaner For Kirloskar Green Genr Set 15 Kva 1.74 Fuel Filetr For Kirloskar Green Genr Set 15 Kva 1.75 Oil Filetr For Kirloskar Green Genr Set 15 Kva 1.76 Fan Belt For Kirloskar Green Genr Set 15 Kva 1.77 V Belt For Kirloskar Green Genr Set 15 Kva 1.78 Rockearm For Kirloskar Green Genr Set 15 Kva 1.79 Tappet Gas Kit For Kirloskar Green Genr Set 15 Kva 1.8 Avr Plate For Kirloskar Green Genr Set 15 Kva 1.81 13Mm Benjo Bolt For Kirloskar Green Genr Set 15 Kva 1.82 19Mm Benjo Bolt For Kirloskar Green Genr Set 15 Kva 1.83 19Mm Benjo Washer For Kirloskar Green Genr Set 15 Kva 1.84 10Mm Benjo Bolt For Kirloskar Green Genr Set 15 Kva 1.85 10Mm Benjo Washer For Kirloskar Green Genr Set 15 Kva 1.86 Cylinder Head For Kirloskar Green Genr Set 15 Kva 1.87 Valve Seal For Kirloskar Green Genr Set 15 Kva 1.88 Piston Ring Sert For Kirloskar Green Genr Set 15 Kva 1.89 Connecting Hell Rod For Kirloskar Green Genr Set 15 Kva 1.9 Overall Kit For Kirloskar Green Genr Set 15 Kva 1.91 Injector For Kirloskar Green Genr Set 15 Kva 1.92 12 Volt 5 Ahc Bty Reqd For Honda Genr Set 2.4 Kva 1.93 Engine Oil Filetr For Kirloskar Genr Set 30 Kva 1.94 Fuel Filetr Primary For Kirloskar Genr Set 30 Kva 1.95 Fuel Filter Secondary For Kirloskar Genr Set 30 Kva 1.96 Fan Belt For Alternator Of Kirloskar Genr Set 30 Kva 1.97 Fan Belt For Blower For Kirloskar Genr Set 30 Kva
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
West Bengal View Result →
24.
Rural Development #10390756 Price Bid
Provide Provide Electrical Material At Grampanchayat Tambati Tal Khalapur Dist Raigad , Supply Elecric Material , Lehar Led 22 Vat , Lehar Led 18 Vat , Syska Led 22 Vat , Syska Led 18 Vat , Philips Led 22 Vat , Philips Led 18 Vat , Syska Led 22 Vat With Sensor , Syska Led 18 Vat With Sensor , Philips Led 22 Vat With Sensor , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led Tube 14 Vat With Chock , Electric Tester (Taparia Co.) , Tripple 40 Ampier , Pannel Board With All Fitting , D.P Switch 32 A , Single Phase Pivantar , Polycab 1.5 Mm Wire , Polycab 2.0 Mm Wire , Cutout Three Phase , Service Wire Aluminium 6 Core , Service Wire Aluminium 8 Core , Service Wire Aluminium 12 Core , Service Cable 3 Phase Coper , Service Cable 4 Phase Coper , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Tripple 32 Ampier , Starter For 3 Hp Pump (Lnt Crompton) , Starter For 5 Hp Pump (Lnt Crompton) , Starter For 15 Hp Pump (Lnt Crompton) , Street Lite Set Led 50 Wat With All Fitting , Pipe For Cement Poll Withclamp, Nut Bolt, Pipe , Pipe For Ironpoll Withclamp, Nut Bolt, Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb60 Vat Philips , Street Lite Set Led, 50 Wat With All Fitting (Micronic Co.) , Street Lite Set Led, 70 Wat With All Fitting (Micronic Co.) , Street Lite Set Led, 100 Wat With All Fitting (Micronic Co.) , Street Lite Set Led, 50 Wat With All Fitting (Syska Co.) , Street Lite Set Led, 70 Wat With All Fitting (Syska Co.) , Street Lite Set Led, 100 Wat With All Fitting (Syska Co.) , Street Lite Set Led, 50 Wat With All Fitting (Philips) , Street Lite Set Led, 70 Wat With All Fitting (Philips) , Street Lite Set Led, 100 Wat With All Fitting (Philips) , Solar Led Streetlight 50 Wat With All Fitting (Syska Co.) , Solar Led Streetlight 70 Wat With All Fitting (Syska Co.) , Solar Led Streetlight 100 Wat With All Fitting (Syska Co.) , Solar Led Streetlight 50 Wat With All Fitting (Philips Co.) , Solar Led Streetlight 70 Wat With All Fitting (Philips Co.) , Solar Led Streetlight 100 Wat With All Fitting (Philips Co.) , Four Phase Cable Wire , One Phase Fitting Wire , Electric Celling Fan (Cromton) , Electric Celling Fan (Havells) , Led Bulb Syska 24Wt , Led Bulb Syska 18Wt , Control Panal 32 Amp , Control Panal 63 Amp , Cfl Bulb 75 Vat (Ajenta) , Cfl Bulb 75 Vat (Crompton) , Screw , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Inverter Luminous 1500 Va (With All Fitting Including Exide Battery) , Inverter Luminous 2000 Va (With All Fitting Including Exide Battery) , Inverter Luminous 2500 Va (With All Fitting Including Exide Battery) , Mccb (Lt) 10Amp , Mccb (Lt) 16Amp , Mccb (Lt) 28Amp , Mccb (Lt) 32Amp , Leg 16 , Leg 18 , Leg 32 , Led Booster (50 Vat) (Micronic Co.) , Led Booster (70 Vat) (Micronic Co.) , Led Booster (50 Vat) (Syska Co.) , Led Booster (70 Vat) (Syska Co.) , Led Booster (50 Vat) (Philips Co.) , Led Booster (70 Vat) (Philips Co.) , Led Stips (50 Vat) (Micronic Co.) , Led Stips (70 Vat) (Micronic Co.) , Led Stips (50 Vat) (Syska Co.) , Led Stips (70 Vat) (Syska Co.) , Led Stips (50 Vat) (Philips Co.) , Led Stips (70 Vat) (Philips Co.) , Air Conditioner (A.C) 1 Ton Carrier (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 1 Ton Blue Star (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 1.5 Ton Blue Star (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 1.5 Ton Carrier (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 2 Ton Blue Star (With Including All Taxes & Service Charges) , Air Conditioner (A.C) 2 Ton Carrier (With Including All Taxes & Service Charges) , Freeze (Samsung) 160 Ltr , Freeze (Samsung) 180 Ltr , Freeze (Lg) 160 Ltr , Freeze (Lg) 180 Ltr , Water Puryfier 12 Ltrs (With Including Taxes & Services) , Elctrical Shagadi Prestige 230Vt , Elctrical Shagadi Prestige 2000Wt , Honda Co. Generator(7 Kva) , Honda Co. Generator(7.5 Kva) , Honda Co. Generator(10 Kva) , Honda Co. Generator(15 Kva) , Honda Co. Generator(20 Kva) , Runmax Co.Generator 13 Kva (Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 15 Kva (Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 20 Kva (Silent Soundproof Power Electric Diesel ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 15 Feet , Aluminium Folding Shidi 20 Feet , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Fan Hook With Nut Bolt , Led Bulb 18 Vatt (Philips) , Led Bulb 24 Vatt (Philips) , Switch Board With3 Switch 2 Plug , Electric Wire , Fan (Usha Co.) , Fan (Orient Co.) , Three Phase Socket , Button (Anchor Co.) , Button (Havells Co.) , Three Pin Socket , Three Pin , Two Pin , Dril Machine , Electric Bell (Havells Co.) , Electric Bell (Anchor Co.) , Led With Sensor (22 Vatt) , Led With Sensor (24 Vatt) , Air Conditioner (A.C) 1 Tone , Air Conditioner (A.C) 1 Tone , Air Conditioner (A.C) 1.5Tone , Air Conditioner (A.C) 1.5 Tone , Air Conditioner (A.C) 2Tone , Air Conditioner (A.C) 2 Tone , Freeze (Samsung ) 160Ltr , Freeze (Samsung ) 180Ltr , Freeze (Lg) 160Ltr , Freeze (Lg ) 180Ltr , Polycab Wire 1Mm , Polycab Wire 1.5Mm , Polycab Wire 2.5Mm , Polycabwire 4Mm , Kessing Electric Patti1/2 , Kessing Electric Patti 3/4 , Kessing Electric Patti 1 , Electric Black Pipe 1/2 , Electric Black Pipe 3/4 , Electric Flexibale Pipe , Tapariya Testar , Tapariy Pakkd , Tariya Srew Driver , Choke Anchar , Choke Philps , Stater Achor , Service Wire Bundle 2.5Mm , Service Wire Bundle 4 Mm , Service Wire Bundle 6 Mm , Service Wire Bundle 8 Mm , Service Wire Bundle 10 Mm , Pipe For Cement Poll With Clamperut Bold , Pipe For Lron Poll With Clam Mut Bold , Four Phase Filling Wire , C.F.L Buld 23 Valt , C.F.L Buld 27 Valt , C.F.L Buld 45 Valt , C.F.L Buld 65 Valt , C.F.L Buld 75 Valt , M.C.C.B 10 Amp Anchor , M.C.C.B 16 Amp Anchor , M.C.C.B 32 Amp Anchor , Eectric Cut Out 63 ?415 , Eectric Tube Firture , Holder For C.F.L.65/75/85 Valt , Four Phase Filling Wire , Cut Out Three Phase 63 Amp P415 V , Streetlight Fintting P.L.Tube , Streetlight Fintting 65 Vat Bult , Meercury Street Light 125M.But , Subrseal Cable 3 Core Heavy Cable Wire For Moatare , 65 Wat Led Light , Bracket For Led Light Philip , Fan , Tube , Stright Light Cover , Swicg Bord , Pump Cable , Ac Cabale , 1.5 Core Cable , 2.5 Core Cable , Tep , Handcglose , Elictric Pole Zula , Melmate , Flexible Cable , Straith Light 36W , Straith Light 50W , Flood Light 100W , Syska Led Bulb 26W , Syska Led Bulb 15W , Aluminiam Bulb Cap , Syska Led Bulb 22W , 4 Pole Mcb 63Amp , Syska Tube Light 20W , Syska Tube Light 36W , Electric Straithpole , Pannel Light 12Mm , Pannel Light18mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
25.
Rural Development #10253499 Price Bid
Provide Electrical Material At Grampanchayat Isambe Tal Khalapur Dist Raigad , Supply Elecric Material , Lehar Led 22 Vat , Lehar Led 18 Vat , Syska Led 22 Vat , Syska Led 18 Vat , Philips Led 22 Vat , Philips Led 18 Vat , Syska Led 22 Vat With Sensor , Syska Led 18 Vat With Sensor , Philips Led 22 Vat With Sensor , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led Tube 14 Vat With Chock , Electric Tester ( Taparia Co. ) , Tripple 40 Ampier , Pannel Board With All Fitting , D.P Switch 32 A , Single Phase Pivantar , Polycab 1.5 Mm Wire , Polycab 2.0 Mm Wire , Cutout Three Phase , Service Wire Aluminium 6 Core , Service Wire Aluminium 8 Core , Service Wire Aluminium 12 Core , Service Cable 3 Phase Coper , Service Cable 4 Phase Coper , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Tripple 32 Ampier , Starter For 3 Hp Pump ( Lnt Crompton ) , Starter For 5 Hp Pump ( Lnt Crompton ) , Starter For 15 Hp Pump ( Lnt Crompton ) , Street Lite Set Led 50 Wat With All Fitting , Pipe For Cement Poll Withclamp, Nut Bolt, Pipe , Pipe For Ironpoll Withclamp, Nut Bolt, Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb60 Vat Philips , Street Lite Set Led, 50 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 50 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 50 Wat With All Fitting ( Philips ) , Street Lite Set Led, 70 Wat With All Fitting ( Philips ) , Street Lite Set Led, 100 Wat With All Fitting ( Philips ) , Solar Led Streetlight 50 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 50 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Philips Co. ) , Four Phase Cable Wire , One Phase Fitting Wire , Electric Celling Fan ( Cromton ) , Electric Celling Fan ( Havells ) , Led Bulb Syska 24Wt , Led Bulb Syska 18Wt , Control Panal 32 Amp , Control Panal 63 Amp , Cfl Bulb 75 Vat ( Ajenta ) , Cfl Bulb 75 Vat ( Crompton ) , Screw , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Inverter Luminous 1500 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2500 Va ( With All Fitting Including Exide Battery ) , Mccb ( Lt ) 10Amp , Mccb ( Lt ) 16Amp , Mccb ( Lt ) 28Amp , Mccb ( Lt ) 32Amp , Leg 16 , Leg 18 , Leg 32 , Led Booster ( 50 Vat ) ( Micronic Co. ) , Led Booster ( 70 Vat ) ( Micronic Co. ) , Led Booster ( 50 Vat ) ( Syska Co. ) , Led Booster ( 70 Vat ) ( Syska Co. ) , Led Booster ( 50 Vat ) ( Philips Co. ) , Led Booster ( 70 Vat ) ( Philips Co. ) , Led Stips ( 50 Vat ) ( Micronic Co. ) , Led Stips ( 70 Vat ) ( Micronic Co. ) , Led Stips ( 50 Vat ) ( Syska Co. ) , Led Stips ( 70 Vat ) ( Syska Co. ) , Led Stips ( 50 Vat ) ( Philips Co. ) , Led Stips ( 70 Vat ) ( Philips Co. ) , Air Conditioner ( A.C ) 1 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1.5 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1.5 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Carrier ( With Including All Taxes & Service Charges ) , Freeze ( Samsung ) 160 Ltr , Freeze ( Samsung ) 180 Ltr , Freeze ( Lg ) 160 Ltr , Freeze ( Lg ) 180 Ltr , Water Puryfier 12 Ltrs ( With Including Taxes & Services ) , Elctrical Shagadi Prestige 230Vt , Elctrical Shagadi Prestige 2000Wt , Honda Co. Generator ( 7 Kva ) , Honda Co. Generator ( 7.5 Kva ) , Honda Co. Generator ( 10 Kva ) , Honda Co. Generator ( 15 Kva ) , Honda Co. Generator ( 20 Kva ) , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 15 Kva ( Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 20 Kva ( Silent Soundproof Power Electric Diesel ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 15 Feet , Aluminium Folding Shidi 20 Feet , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Fan Hook With Nut Bolt , Led Bulb 18 Vatt ( Philips ) , Led Bulb 24 Vatt ( Philips ) , Switch Board With3 Switch 2 Plug , Electric Wire , Fan ( Usha Co. ) , Fan ( Orient Co. ) , Three Phase Socket , Button ( Anchor Co. ) , Button ( Havells Co. ) , Three Pin Socket , Three Pin , Two Pin , Dril Machine , Electric Bell ( Havells Co. ) , Electric Bell ( Anchor Co. ) , Led With Sensor ( 22 Vatt ) , Led With Sensor ( 24 Vatt ) , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1.5Tone , Air Conditioner ( A.C ) 1.5 Tone , Air Conditioner ( A.C ) 2Tone , Air Conditioner ( A.C ) 2 Tone , Freeze ( Samsung ) 160Ltr , Freeze ( Samsung ) 180Ltr , Freeze ( Lg ) 160Ltr , Freeze ( Lg ) 180Ltr , Polycab Wire 1Mm , Polycab Wire 1.5Mm , Polycab Wire 2.5Mm , Polycabwire 4Mm , Kessing Electric Patti1 / 2 , Kessing Electric Patti 3 / 4 , Kessing Electric Patti 1 , Electric Black Pipe 1 / 2 , Electric Black Pipe 3 / 4 , Electric Flexibale Pipe , Tapariya Testar , Tapariy Pakkd , Tariya Srew Driver , Choke Anchar , Choke Philps , Stater Achor , Service Wire Bundle 2.5Mm , Service Wire Bundle 4 Mm , Service Wire Bundle 6 Mm , Service Wire Bundle 8 Mm , Service Wire Bundle 10 Mm , Pipe For Cement Poll With Clamperut Bold , Pipe For Lron Poll With Clam Mut Bold , Four Phase Filling Wire , C.F.L Buld 23 Valt , C.F.L Buld 27 Valt , C.F.L Buld 45 Valt , C.F.L Buld 65 Valt , C.F.L Buld 75 Valt , M.C.C.B 10 Amp Anchor , M.C.C.B 16 Amp Anchor , M.C.C.B 32 Amp Anchor , Eectric Cut Out 63 ?415 , Eectric Tube Firture , Holder For C.F.L.65 / 75 / 85 Valt , Four Phase Filling Wire , Cut Out Three Phase 63 Amp P415 V , Streetlight Fintting P.L.Tube , Streetlight Fintting 65 Vat Bult , Meercury Street Light 125M.But , Subrseal Cable 3 Core Heavy Cable Wire For Moatare , 65 Wat Led Light , Bracket For Led Light Philip , Fan , Tube , Stright Light Cover , Swicg Bord , Pump Cable , Ac Cabale , 1.5 Core Cable , 2.5 Core Cable , Tep , Handcglose , Elictric Pole Zula , Melmate , Flexible Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
26.
Rural Development #10253480 Price Bid
Provide Provide Electrical Material At Grampanchayat Lodhiwali Tal Khalapur Dist Raigad , Supply Elecric Material , Lehar Led 22 Vat , Lehar Led 18 Vat , Syska Led 22 Vat , Syska Led 18 Vat , Philips Led 22 Vat , Philips Led 18 Vat , Syska Led 22 Vat With Sensor , Syska Led 18 Vat With Sensor , Philips Led 22 Vat With Sensor , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led Tube 14 Vat With Chock , Electric Tester ( Taparia Co. ) , Tripple 40 Ampier , Pannel Board With All Fitting , D.P Switch 32 A , Single Phase Pivantar , Polycab 1.5 Mm Wire , Polycab 2.0 Mm Wire , Cutout Three Phase , Service Wire Aluminium 6 Core , Service Wire Aluminium 8 Core , Service Wire Aluminium 12 Core , Service Cable 3 Phase Coper , Service Cable 4 Phase Coper , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Tripple 32 Ampier , Starter For 3 Hp Pump ( Lnt Crompton ) , Starter For 5 Hp Pump ( Lnt Crompton ) , Starter For 15 Hp Pump ( Lnt Crompton ) , Street Lite Set Led 50 Wat With All Fitting , Pipe For Cement Poll Withclamp, Nut Bolt, Pipe , Pipe For Ironpoll Withclamp, Nut Bolt, Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb60 Vat Philips , Street Lite Set Led, 50 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Micronic Co. ) , Street Lite Set Led, 50 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 50 Wat With All Fitting ( Philips ) , Street Lite Set Led, 70 Wat With All Fitting ( Philips ) , Street Lite Set Led, 100 Wat With All Fitting ( Philips ) , Solar Led Streetlight 50 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 50 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Philips Co. ) , Four Phase Cable Wire , One Phase Fitting Wire , Electric Celling Fan ( Cromton ) , Electric Celling Fan ( Havells ) , Led Bulb Syska 24Wt , Led Bulb Syska 18Wt , Control Panal 32 Amp , Control Panal 63 Amp , Cfl Bulb 75 Vat ( Ajenta ) , Cfl Bulb 75 Vat ( Crompton ) , Screw , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Inverter Luminous 1500 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2500 Va ( With All Fitting Including Exide Battery ) , Mccb ( Lt ) 10Amp , Mccb ( Lt ) 16Amp , Mccb ( Lt ) 28Amp , Mccb ( Lt ) 32Amp , Leg 16 , Leg 18 , Leg 32 , Led Booster ( 50 Vat ) ( Micronic Co. ) , Led Booster ( 70 Vat ) ( Micronic Co. ) , Led Booster ( 50 Vat ) ( Syska Co. ) , Led Booster ( 70 Vat ) ( Syska Co. ) , Led Booster ( 50 Vat ) ( Philips Co. ) , Led Booster ( 70 Vat ) ( Philips Co. ) , Led Stips ( 50 Vat ) ( Micronic Co. ) , Led Stips ( 70 Vat ) ( Micronic Co. ) , Led Stips ( 50 Vat ) ( Syska Co. ) , Led Stips ( 70 Vat ) ( Syska Co. ) , Led Stips ( 50 Vat ) ( Philips Co. ) , Led Stips ( 70 Vat ) ( Philips Co. ) , Air Conditioner ( A.C ) 1 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1.5 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1.5 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Carrier ( With Including All Taxes & Service Charges ) , Freeze ( Samsung ) 160 Ltr , Freeze ( Samsung ) 180 Ltr , Freeze ( Lg ) 160 Ltr , Freeze ( Lg ) 180 Ltr , Water Puryfier 12 Ltrs ( With Including Taxes & Services ) , Elctrical Shagadi Prestige 230Vt , Elctrical Shagadi Prestige 2000Wt , Honda Co. Generator ( 7 Kva ) , Honda Co. Generator ( 7.5 Kva ) , Honda Co. Generator ( 10 Kva ) , Honda Co. Generator ( 15 Kva ) , Honda Co. Generator ( 20 Kva ) , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 15 Kva ( Silent Soundproof Power Electric Diesel ) , Runmax Co.Generator 20 Kva ( Silent Soundproof Power Electric Diesel ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 15 Feet , Aluminium Folding Shidi 20 Feet , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Fan Hook With Nut Bolt , Led Bulb 18 Vatt ( Philips ) , Led Bulb 24 Vatt ( Philips ) , Switch Board With3 Switch 2 Plug , Electric Wire , Fan ( Usha Co. ) , Fan ( Orient Co. ) , Three Phase Socket , Button ( Anchor Co. ) , Button ( Havells Co. ) , Three Pin Socket , Three Pin , Two Pin , Dril Machine , Electric Bell ( Havells Co. ) , Electric Bell ( Anchor Co. ) , Led With Sensor ( 22 Vatt ) , Led With Sensor ( 24 Vatt ) , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1.5Tone , Air Conditioner ( A.C ) 1.5 Tone , Air Conditioner ( A.C ) 2Tone , Air Conditioner ( A.C ) 2 Tone , Freeze ( Samsung ) 160Ltr , Freeze ( Samsung ) 180Ltr , Freeze ( Lg ) 160Ltr , Freeze ( Lg ) 180Ltr , Polycab Wire 1Mm , Polycab Wire 1.5Mm , Polycab Wire 2.5Mm , Polycabwire 4Mm , Kessing Electric Patti1 / 2 , Kessing Electric Patti 3 / 4 , Kessing Electric Patti 1 , Electric Black Pipe 1 / 2 , Electric Black Pipe 3 / 4 , Electric Flexibale Pipe , Tapariya Testar , Tapariy Pakkd , Tariya Srew Driver , Choke Anchar , Choke Philps , Stater Achor , Service Wire Bundle 2.5Mm , Service Wire Bundle 4 Mm , Service Wire Bundle 6 Mm , Service Wire Bundle 8 Mm , Service Wire Bundle 10 Mm , Pipe For Cement Poll With Clamperut Bold , Pipe For Lron Poll With Clam Mut Bold , Four Phase Filling Wire , C.F.L Buld 23 Valt , C.F.L Buld 27 Valt , C.F.L Buld 45 Valt , C.F.L Buld 65 Valt , C.F.L Buld 75 Valt , M.C.C.B 10 Amp Anchor , M.C.C.B 16 Amp Anchor , M.C.C.B 32 Amp Anchor , Eectric Cut Out 63 ?415 , Eectric Tube Firture , Holder For C.F.L.65 / 75 / 85 Valt , Four Phase Filling Wire , Cut Out Three Phase 63 Amp P415 V , Streetlight Fintting P.L.Tube , Streetlight Fintting 65 Vat Bult , Meercury Street Light 125M.But , Subrseal Cable 3 Core Heavy Cable Wire For Moatare , 65 Wat Led Light , Bracket For Led Light Philip , Fan , Tube , Stright Light Cover , Swicg Bord , Pump Cable , Ac Cabale , 1.5 Core Cable , 2.5 Core Cable , Tep , Handcglose , Elictric Pole Zula , Melmate , Flexible Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
27.
Rural Development #10253422 Price Bid
Provide Provide Electrical Material At Grampanchayat Chouk Tal Khalapur Dist Raigad , Supply Elecric Material , Service Wire Aluminium 12 Core , Philips Led 18 Vat With Sensor , Lehar Led 22 Vat , Tripple 40 Ampier , Lehar Led 18 Vat , Polycab 2.0 Mm Wire , Syska Led 18 Vat , Philips Led 18 Vat With Sensor , Philips Led 22 Vat , Polycab 2.0 Mm Wire , Syska Led 22 Vat With Sensor , Street Lite Set Led, 50 Wat With All Fitting ( Micronic Co. ) , Syska Led 18 Vat With Sensor , Philips Led 22 Vat With Sensor , Service Wire Aluminium 8 Core , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led 18 Vat , Philips Led Tube 14 Vat With Chock , Electric Tester ( Taparia Co. ) , Tripple 40 Ampier , Pannel Board With All Fitting , D.P Switch 32 A , Led Bulb Syska 24Wt , Street Lite Set Led, 70 Wat With All Fitting ( Micronic Co. ) , Polycab 1.5 Mm Wire , Polycab 2.0 Mm Wire , Cutout Three Phase , Syska Led 22 Vat , Service Wire Aluminium 6 Core , Single Phase Pivantar , 1.5 Core Cable , Service Cable 3 Phase Coper , Swicg Bord , Pump Cable , Service Wire Aluminium 8 Core , Ac Cabale , 1.5 Core Cable , 2.5 Core Cable , Cutout Three Phase , Tep , Handcglose , Elictric Pole Zula , Mccb ( Lt ) 32Amp , Melmate , Flexible Cable , Service Cable 4 Phase Coper , Street Lite Set Led, 50 Wat With All Fitting ( Philips ) , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Single Phase Pivantar , Tripple 32 Ampier , Starter For 3 Hp Pump ( Lnt Crompton ) , Starter For 5 Hp Pump ( Lnt Crompton ) , Philips Led 18 Vat With Sensor , Starter For 15 Hp Pump ( Lnt Crompton ) , Street Lite Set Led 50 Wat With All Fitting , Led Stips ( 70 Vat ) ( Micronic Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Syska Co. ) , Pipe For Ironpoll Withclamp, Nut Bolt, Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb60 Vat Philips , Street Lite Set Led, 50 Wat With All Fitting ( Micronic Co. ) , Pipe For Cement Poll Withclamp, Nut Bolt, Pipe , Street Lite Set Led, 50 Wat With All Fitting ( Philips ) , Street Lite Set Led, 100 Wat With All Fitting ( Micronic Co. ) , Starter For 3 Hp Pump ( Lnt Crompton ) , Street Lite Set Led, 50 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Philips ) , Street Lite Set Led, 100 Wat With All Fitting ( Philips ) , Solar Led Streetlight 50 Wat With All Fitting ( Syska Co. ) , One Phase Fitting Wire , Solar Led Streetlight 70 Wat With All Fitting ( Syska Co. ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Street Lite Set Led 50 Wat With All Fitting , Solar Led Streetlight 50 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Philips Co. ) , Four Phase Cable Wire , Electric Celling Fan ( Cromton ) , Control Panal 32 Amp , Electric Celling Fan ( Havells ) , Led Bulb Syska 24Wt , Service Cable 4 Phase Coper , Led Bulb Syska 18Wt , Air Conditioner ( A.C ) 1.5 Ton Blue Star ( With Including All Taxes & Service Charges ) , Control Panal 63 Amp , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Cfl Bulb 75 Vat ( Ajenta ) , Cfl Bulb 75 Vat ( Crompton ) , Screw , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Mccb ( Lt ) 10Amp , Inverter Luminous 1500 Va ( With All Fitting Including Exide Battery ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Inverter Luminous 2500 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Mccb ( Lt ) 16Amp , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel ) , Mccb ( Lt ) 28Amp , Leg 16 , Mccb ( Lt ) 32Amp , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Leg 18 , Led Booster ( 50 Vat ) ( Micronic Co. ) , Leg 32 , Led Stips ( 70 Vat ) ( Philips Co. ) , Led Booster ( 70 Vat ) ( Micronic Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Led Booster ( 50 Vat ) ( Syska Co. ) , Polycab Wire 1Mm , Led Booster ( 70 Vat ) ( Syska Co. ) , Button ( Havells Co. ) , Led Booster ( 50 Vat ) ( Philips Co. ) , Led Booster ( 70 Vat ) ( Philips Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Philips ) , Led Stips ( 50 Vat ) ( Micronic Co. ) , Led Stips ( 70 Vat ) ( Micronic Co. ) , Led Stips ( 50 Vat ) ( Syska Co. ) , Led Stips ( 70 Vat ) ( Syska Co. ) , Air Conditioner ( A.C ) 1 Ton Carrier ( With Including All Taxes & Service Charges ) , Led Stips ( 50 Vat ) ( Philips Co. ) , Led Stips ( 70 Vat ) ( Philips Co. ) , Electric Bell ( Anchor Co. ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Air Conditioner ( A.C ) 2 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1 Ton Blue Star ( With Including All Taxes & Service Charges ) , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel ) , Air Conditioner ( A.C ) 1.5 Ton Blue Star ( With Including All Taxes & Service Charges ) , Freeze ( Samsung ) 160 Ltr , Air Conditioner ( A.C ) 1.5 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Carrier ( With Including All Taxes & Service Charges ) , Freeze ( Samsung ) 180 Ltr , Freeze ( Lg ) 160 Ltr , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel ) , Water Puryfier 12 Ltrs ( With Including Taxes & Services ) , Elctrical Shagadi Prestige 230Vt , Honda Co. Generator ( 10 Kva ) , Elctrical Shagadi Prestige 2000Wt , Honda Co. Generator ( 7 Kva ) , Honda Co. Generator ( 15 Kva ) , Honda Co. Generator ( 20 Kva ) , Runmax Co.Generator 15 Kva ( Silent Soundproof Power Electric Diesel ) , Honda Co. Generator ( 7.5 Kva ) , Runmax Co.Generator 20 Kva ( Silent Soundproof Power Electric Diesel ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 20 Feet , Polycabwire 4Mm , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , Freeze ( Lg ) 160Ltr , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Electric Wire , Fan Hook With Nut Bolt , Led Bulb 18 Vatt ( Philips ) , Switch Board With3 Switch 2 Plug , Button ( Anchor Co. ) , Fan ( Usha Co. ) , Electric Bell ( Anchor Co. ) , Fan ( Orient Co. ) , Led Fitting Charges , Button ( Anchor Co. ) , Freeze ( Samsung ) 160Ltr , Led Bulb 24 Vatt ( Philips ) , Three Pin Socket , Electric Safety Hand Gloves , Two Pin , Dril Machine , Freeze ( Lg ) 180 Ltr , Electric Bell ( Havells Co. ) , Three Phase Socket , Led With Sensor ( 22 Vatt ) , Three Pin , Led With Sensor ( 24 Vatt ) , Air Conditioner ( A.C ) 1 Tone , Button ( Anchor Co. ) , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1.5Tone , Kessing Electric Patti 1 , Button ( Anchor Co. ) , Air Conditioner ( A.C ) 2Tone , 1.5 Core Cable , Led Fitting Charges , Freeze ( Samsung ) 180Ltr , Service Wire Bundle 6 Mm , Polycabwire 4Mm , Freeze ( Lg ) 180Ltr , Air Conditioner ( A.C ) 1.5 Tone , Polycab Wire 1.5Mm , Kessing Electric Patti 1 , Polycab Wire 2.5Mm , Led With Sensor ( 24 Vatt ) , Tariya Srew Driver , Kessing Electric Patti1 / 2 , Four Phase Filling Wire , Electric Black Pipe 1 / 2 , Electric Black Pipe 3 / 4 , Air Conditioner ( A.C ) 2 Tone , Electric Flexibale Pipe , Tapariya Testar , Tapariy Pakkd , Polycab Wire 1.5Mm , Choke Anchar , Kessing Electric Patti 3 / 4 , Choke Philps , Stater Achor , Service Wire Bundle 2.5Mm , Service Wire Bundle 4 Mm , Service Wire Bundle 8 Mm , Cut Out Three Phase 63 Amp P415 V , Service Wire Bundle 10 Mm , Pipe For Cement Poll With Clamperut Bold , Pipe For Lron Poll With Clam Mut Bold , Streetlight Fintting 65 Vat Bult , Service Wire Bundle 10 Mm , C.F.L Buld 23 Valt , Elictric Pole Zula , C.F.L Buld 27 Valt , Handcglose , C.F.L Buld 45 Valt , C.F.L Buld 65 Valt , C.F.L Buld 75 Valt , Melmate , Polycab Wire 1.5Mm , M.C.C.B 16 Amp Anchor , Tep , M.C.C.B 32 Amp Anchor , Eectric Cut Out 63 ?415 , Eectric Tube Firture , Holder For C.F.L.65 / 75 / 85 Valt , Flexible Cable , Four Phase Filling Wire , 2.5 Core Cable , Streetlight Fintting P.L.Tube , Pump Cable , Meercury Street Light 125M.But , Subrseal Cable 3 Core Heavy Cable Wire For Moatare , 65 Wat Led Light , Bracket For Led Light Philip , Fan , Tube , Swicg Bord , Ac Cabale , Aluminium Folding Shidi 15 Feet , Stright Light Cover , M.C.C.B 10 Amp Anchor , C.F.L Buld 65 Valt , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Electric Wire , Fan Hook With Nut Bolt , Led Bulb 18 Vatt ( Philips ) , Motar 10 Hp
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
28.
Rural Development #10253354 Price Bid
Provide Provide Electrical Material At Grampanchayat Saavroli Tal Khalapur Dist Raigad , Supply Elecric Material , Service Wire Aluminium 12 Core , Philips Led 18 Vat With Sensor , Lehar Led 22 Vat , Tripple 40 Ampier , Lehar Led 18 Vat , Polycab 2.0 Mm Wire , Syska Led 18 Vat , Philips Led 18 Vat With Sensor , Philips Led 22 Vat , Polycab 2.0 Mm Wire , Syska Led 22 Vat With Sensor , Street Lite Set Led, 50 Wat With All Fitting ( Micronic Co. ) , Syska Led 18 Vat With Sensor , Philips Led 22 Vat With Sensor , Service Wire Aluminium 8 Core , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led 18 Vat , Philips Led Tube 14 Vat With Chock , Electric Tester ( Taparia Co. ) , Tripple 40 Ampier , Pannel Board With All Fitting , D.P Switch 32 A , Led Bulb Syska 24Wt , Street Lite Set Led, 70 Wat With All Fitting ( Micronic Co. ) , Polycab 1.5 Mm Wire , Polycab 2.0 Mm Wire , Cutout Three Phase , Syska Led 22 Vat , Service Wire Aluminium 6 Core , Single Phase Pivantar , 1.5 Core Cable , Service Cable 3 Phase Coper , Swicg Bord , Pump Cable , Service Wire Aluminium 8 Core , Ac Cabale , 1.5 Core Cable , 2.5 Core Cable , Cutout Three Phase , Tep , Handcglose , Elictric Pole Zula , Mccb ( Lt ) 32Amp , Melmate , Flexible Cable , Service Cable 4 Phase Coper , Street Lite Set Led, 50 Wat With All Fitting ( Philips ) , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Single Phase Pivantar , Tripple 32 Ampier , Starter For 3 Hp Pump ( Lnt Crompton ) , Starter For 5 Hp Pump ( Lnt Crompton ) , Philips Led 18 Vat With Sensor , Starter For 15 Hp Pump ( Lnt Crompton ) , Street Lite Set Led 50 Wat With All Fitting , Led Stips ( 70 Vat ) ( Micronic Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Syska Co. ) , Pipe For Ironpoll Withclamp, Nut Bolt, Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb60 Vat Philips , Street Lite Set Led, 50 Wat With All Fitting ( Micronic Co. ) , Pipe For Cement Poll Withclamp, Nut Bolt, Pipe , Street Lite Set Led, 50 Wat With All Fitting ( Philips ) , Street Lite Set Led, 100 Wat With All Fitting ( Micronic Co. ) , Starter For 3 Hp Pump ( Lnt Crompton ) , Street Lite Set Led, 50 Wat With All Fitting ( Syska Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Syska Co. ) , Street Lite Set Led, 70 Wat With All Fitting ( Philips ) , Street Lite Set Led, 100 Wat With All Fitting ( Philips ) , Solar Led Streetlight 50 Wat With All Fitting ( Syska Co. ) , One Phase Fitting Wire , Solar Led Streetlight 70 Wat With All Fitting ( Syska Co. ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Street Lite Set Led 50 Wat With All Fitting , Solar Led Streetlight 50 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Solar Led Streetlight 100 Wat With All Fitting ( Philips Co. ) , Four Phase Cable Wire , Electric Celling Fan ( Cromton ) , Control Panal 32 Amp , Electric Celling Fan ( Havells ) , Led Bulb Syska 24Wt , Service Cable 4 Phase Coper , Led Bulb Syska 18Wt , Air Conditioner ( A.C ) 1.5 Ton Blue Star ( With Including All Taxes & Service Charges ) , Control Panal 63 Amp , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Cfl Bulb 75 Vat ( Ajenta ) , Cfl Bulb 75 Vat ( Crompton ) , Screw , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Mccb ( Lt ) 10Amp , Inverter Luminous 1500 Va ( With All Fitting Including Exide Battery ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Inverter Luminous 2500 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Mccb ( Lt ) 16Amp , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel ) , Mccb ( Lt ) 28Amp , Leg 16 , Mccb ( Lt ) 32Amp , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Leg 18 , Led Booster ( 50 Vat ) ( Micronic Co. ) , Leg 32 , Led Stips ( 70 Vat ) ( Philips Co. ) , Led Booster ( 70 Vat ) ( Micronic Co. ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co. ) , Led Booster ( 50 Vat ) ( Syska Co. ) , Polycab Wire 1Mm , Led Booster ( 70 Vat ) ( Syska Co. ) , Button ( Havells Co. ) , Led Booster ( 50 Vat ) ( Philips Co. ) , Led Booster ( 70 Vat ) ( Philips Co. ) , Street Lite Set Led, 100 Wat With All Fitting ( Philips ) , Led Stips ( 50 Vat ) ( Micronic Co. ) , Led Stips ( 70 Vat ) ( Micronic Co. ) , Led Stips ( 50 Vat ) ( Syska Co. ) , Led Stips ( 70 Vat ) ( Syska Co. ) , Air Conditioner ( A.C ) 1 Ton Carrier ( With Including All Taxes & Service Charges ) , Led Stips ( 50 Vat ) ( Philips Co. ) , Led Stips ( 70 Vat ) ( Philips Co. ) , Electric Bell ( Anchor Co. ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Air Conditioner ( A.C ) 2 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 1 Ton Blue Star ( With Including All Taxes & Service Charges ) , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel ) , Air Conditioner ( A.C ) 1.5 Ton Blue Star ( With Including All Taxes & Service Charges ) , Freeze ( Samsung ) 160 Ltr , Air Conditioner ( A.C ) 1.5 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A.C ) 2 Ton Carrier ( With Including All Taxes & Service Charges ) , Freeze ( Samsung ) 180 Ltr , Freeze ( Lg ) 160 Ltr , Runmax Co.Generator 13 Kva ( Silent Soundproof Power Electric Diesel ) , Water Puryfier 12 Ltrs ( With Including Taxes & Services ) , Elctrical Shagadi Prestige 230Vt , Honda Co. Generator ( 10 Kva ) , Elctrical Shagadi Prestige 2000Wt , Honda Co. Generator ( 7 Kva ) , Honda Co. Generator ( 15 Kva ) , Honda Co. Generator ( 20 Kva ) , Runmax Co.Generator 15 Kva ( Silent Soundproof Power Electric Diesel ) , Honda Co. Generator ( 7.5 Kva ) , Runmax Co.Generator 20 Kva ( Silent Soundproof Power Electric Diesel ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 20 Feet , Polycabwire 4Mm , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , Freeze ( Lg ) 160Ltr , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Electric Wire , Fan Hook With Nut Bolt , Led Bulb 18 Vatt ( Philips ) , Switch Board With3 Switch 2 Plug , Button ( Anchor Co. ) , Fan ( Usha Co. ) , Electric Bell ( Anchor Co. ) , Fan ( Orient Co. ) , Led Fitting Charges , Button ( Anchor Co. ) , Freeze ( Samsung ) 160Ltr , Led Bulb 24 Vatt ( Philips ) , Three Pin Socket , Electric Safety Hand Gloves , Two Pin , Dril Machine , Freeze ( Lg ) 180 Ltr , Electric Bell ( Havells Co. ) , Three Phase Socket , Led With Sensor ( 22 Vatt ) , Three Pin , Led With Sensor ( 24 Vatt ) , Air Conditioner ( A.C ) 1 Tone , Button ( Anchor Co. ) , Air Conditioner ( A.C ) 1 Tone , Air Conditioner ( A.C ) 1.5Tone , Kessing Electric Patti 1 , Button ( Anchor Co. ) , Air Conditioner ( A.C ) 2Tone , 1.5 Core Cable , Led Fitting Charges , Freeze ( Samsung ) 180Ltr , Service Wire Bundle 6 Mm , Polycabwire 4Mm , Freeze ( Lg ) 180Ltr , Air Conditioner ( A.C ) 1.5 Tone , Polycab Wire 1.5Mm , Kessing Electric Patti 1 , Polycab Wire 2.5Mm , Led With Sensor ( 24 Vatt ) , Tariya Srew Driver , Kessing Electric Patti1 / 2 , Four Phase Filling Wire , Electric Black Pipe 1 / 2 , Electric Black Pipe 3 / 4 , Air Conditioner ( A.C ) 2 Tone , Electric Flexibale Pipe , Tapariya Testar , Tapariy Pakkd , Polycab Wire 1.5Mm , Choke Anchar , Kessing Electric Patti 3 / 4 , Choke Philps , Stater Achor , Service Wire Bundle 2.5Mm , Service Wire Bundle 4 Mm , Service Wire Bundle 8 Mm , Cut Out Three Phase 63 Amp P415 V , Service Wire Bundle 10 Mm , Pipe For Cement Poll With Clamperut Bold , Pipe For Lron Poll With Clam Mut Bold , Streetlight Fintting 65 Vat Bult , Service Wire Bundle 10 Mm , C.F.L Buld 23 Valt , Elictric Pole Zula , C.F.L Buld 27 Valt , Handcglose , C.F.L Buld 45 Valt , C.F.L Buld 65 Valt , C.F.L Buld 75 Valt , Melmate , Polycab Wire 1.5Mm , M.C.C.B 16 Amp Anchor , Tep , M.C.C.B 32 Amp Anchor , Eectric Cut Out 63 ?415 , Eectric Tube Firture , Holder For C.F.L.65 / 75 / 85 Valt , Flexible Cable , Four Phase Filling Wire , 2.5 Core Cable , Streetlight Fintting P.L.Tube , Pump Cable , Meercury Street Light 125M.But , Subrseal Cable 3 Core Heavy Cable Wire For Moatare , 65 Wat Led Light , Bracket For Led Light Philip , Fan , Tube , Swicg Bord , Ac Cabale , Aluminium Folding Shidi 15 Feet , Stright Light Cover , M.C.C.B 10 Amp Anchor , C.F.L Buld 65 Valt , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Electric Wire , Fan Hook With Nut Bolt , Led Bulb 18 Vatt ( Philips ) , Motar 10 Hp
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
29.
Banking and Finance #10242707 Price Bid
Annual Repair and Maintenance[Civil & Electrical] works to ESIC BO,Dispensaries and Quarters at Tambaram,Pallavaram,Nandabakkam,Ambattur,Ambattur estate, Avadi, Korrattur, kaladipet,Tondairpet,Georgetown,Triplicane,Redhills,Choolai : Chennai for the period of 12 months [1-year] ; 1 Laying and Jointing PVC Pipe. Heading 2 Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 3 Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 4 Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 5 Supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 6 Supply of 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 7 Supply of 20 mm iron staples/ saddles/ screws 8 Supply of 25 mm iron staples/ saddles/ screws 9 Supply of 20 mm dia. ISI marked, PVC conduit 10 Supply of 25 mm dia. ISI marked, PVC conduit 11 Supply of 32 mm dia. ISI marked, PVC conduit 12 Supply of 20 mm PVC bends 13 Supply of 25 mm PVC bends 14 Supply of 20 mm PVC couplers 15 Supply of 25 mm PVC couplers 16 Supply of 20 mm PVC junction box, one way 17 Supply of 20 mm PVC junction box, two way 18 Supply of 75 mm X 75 mm X 50 mm PVC box 19 Supply of Modular GI box for 2 module 20 Supply of Modular GI box for 3 module 21 Supply of Modular GI box for 4module 22 Supply of Modular GI box for 6 module 23 Supply of Modular GI box for 8 module 24 Supply of Modular GI box for 12 module 25 Supply of Ceiling rose, 3 pin, 5 amps ISI marked 26 Supply of S.P. 5/6 amps, one way modular switch, ISI marked 27 Supply of S.P. 15/16 amps, one way modular switch, ISI marked 28 Supply of 3 pin 5/6 amps modular socket outlet, ISI marked 29 Supply of 6 pin 15/16 amps modular socket outlet, ISI marked 30 Supply of Modular bell push, ISI marked 31 Supply of Stepped type Modular Fan regulator (2 module) 32 Supply of Modular blanking plate 33 Supply of 6 pin 25 amp modular type socket ISI Marked 34 Supply of Modular base & cover plate for 1 module 35 Supply of Modular base & cover plate for 2 module 36 Supply of Modular base & cover plate for 3 module 37 Supply of Modular base & cover plate for 4 module 38 Supply of Modular base & cover plate for 6module 39 Supply of Modular base & cover plate for 8module 40 Supply of Modular base & cover plate for 12module 41 Supply of S.P. 5/6 A, one way switch, piano type ISI marked 42 Supply of S.P. 5/6 A, two way switch, piano type ISI marked 43 Supply of S.P. 15/16 A, one way switch, piano type ISI marked 44 Supply of 3 pin 5/6 A socket outlet, piano type ISI marked 45 Supply of 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked 46 Supply of Bell push, piano type 47 Supply of Call bell/ buzzer, single phase 48 Supply of PVC Batten/Angle Holder 49 Supply of 6 amps. to 32 amps. ratings , SP MCB, C curve, 10 KA breaking capacity 50 Supply of 6 amps. to 32 amps. ratings , SPN MCB, C curve, 10 KA breaking capacity 51 Supply of 6 amps. to 32 amps. ratings , TPN MCB, “C” curve,10 KA breaking capacity 52 Supply of Single pole, Blanking plate 53 Supply of 40 amps., 4 pole isolator 54 Supply of 63 amps., 4 pole isolator 55 Supply of 25 amps. rating, 2 pole RCCB, 30mA 56 Supply of 40 amps. rating, 2 pole RCCB, 30mA 57 Supply of 63 amps. rating, 2 pole RCCB, 30mA 58 Supply of 20 amps. SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure 59 Supply of 4 way (4+12), TPN, MCB DB, double door,horizontal type 60 Supply of 6 way (4+18), TPN, MCB DB, double door,horizontal type 61 Supply of 8 way (4+24), TPN, MCB DB, double door, horizontal type 62 Supply of Brass compression gland for (28 mm) 4 X 16 sq. mm 1.1 KV grade cable 63 Supply of Brass compression gland for (28 mm) 3½ X 25 sq. mm 1.1 KV grade cable 64 Supply of Brass compression gland for (32 mm) 3½ X 35 sq. mm 1.1 KV grade cable 65 Supply of Brass compression gland for (35 mm) 3½ X 50 sq. mm 1.1 KV grade cable 66 Supply of Brass compression gland for (38 mm) 3½ X 70 sq. mm 1.1 KV grade cable 67 Supply of Aluminium lugs for 6 sq. mm cable 68 Supply of Aluminium lugs for 10 sq. mm cable 69 Supply of Aluminium lugs for 16 sq. mm cable 70 Supply of Aluminium lugs for 25 sq. mm cable 71 Supply of Aluminium lugs for 35 sq. mm cable 72 Supply of Aluminium lugs for 50 sq. mm cable 73 Supply of Aluminium lugs for 70 sq. mm cable 74 Supply of Aluminium lugs for 95 sq. mm cable 75 Supply of Aluminium lugs for 120 sq. mm cable 76 Supply of 16 mm X 50 mm bolts and nuts with washers 77 Supply of 16 mm X 125 mm bolts and nuts with washers 78 Supply of Steel fastener 6 mm X 75 mm 79 Supply of Steel fastener 8 mm X 75 mm 80 Supply of Rubber/ PVC bushes 81 Supply of 6 mm dia rivet/ stud/ bolts and nuts 82 Supply of GI saddles 19mm x 0.55mm for conduit 83 Supply of GI saddles 25mm x 0.90mm for conduit above 25mm 84 Supply of 200 mm X 150 mm M.V. danger notice plate 85 Supply of Coke 86 Supply of Salt 87 Supplyandfixing of 4’ 18W Crystal Glass LED Tube Light Fitting 88 Supplyandfixing 7W / 9W LED Bulb 89 Supplyandfixing 15W LED Bulb 90 Supplyandfixing 30W LED Street Light Fitting with LED 91 Supplyandfixing 48W LED Street Light Fitting with LED 92 Supplyandfixing Ceiling Rose 93 Supplyandfixing Call Bell / Buzzer 6mm suitable for AC / DC 94 Supplyandfixing Push Bell 95 Supplyandfixing AC Ceiling Fan complete 1200 mm (48”) Sweep with 300mm Down Rod (without Regulator) 96 Supplyandfixing Dimmer Type Electronic 300W / 450W Square Type Fan Regulator 97 Supplyandfixing AC Exhaust Fan 300mm (12”) Sweep (Light Duty) 98 Supplyandfixing MS / Fibre Louvers Shutters arrangements for 300mm AC Exhaust Fan 99 Supplyandfixing MS / Fibre Louvers Shutters arrangements for 375mm AC Exhaust Fan 100 Supplyandfixing MS / Fibre Louvers Shutters arrangements for 450mm AC Exhaust Fan 101 Supplyandfixing 48” Ceiling Fan 5 Star Rated (without Regulator) HIGHER END 102 Supplyandfixing 300mm Sweep WALL MOUNTING FAN 103 Supplyandfixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END 104 Supplyandfixing Surface Box - 1/2 Module 105 Supplyandfixing Surface Box - 3 Module 106 Supplyandfixing Surface Box - 4 Module 107 Supplyandfixing Surface Box - 6 Module 108 Supplyandfixing Surface Box - 8 Module 109 Supplyandfixing Surface Box - 8 (2 row x 4) Module 110 Supplyandfixing Metal Surface Box - 12/16 (2 row x 6) Module 111 Supplyandfixing Metal Surface Box - 18 Module 112 Supplyandfixing 5 Amps 3 Pin & 2 Pin Combined Flush Type Wall Socket only 113 Supplyandfixing 5 Amps / 15 Amps 3 Pin Flush Type Wall Socket only 114 Supplyandfixing 5 Amps 3 Pin Top 115 Supplyandfixing 5 Amps 3 Pin Top 116 Supplyandfixing 15 Amps Flush Type Switch 117 Supplyandfixing 10 Amps MC Plug with 3 Pin Top 118 Supplyandfixing 20 Amps MC Plug with 3 Pin Top 119 Supplyandfixing 25A Flush type Wall Socket with 25A DP MCB for AC Plug 120 Supply and fixing of Rewirable Fuse (Kit-Kat) with Fuse base & Fuse carrier are made of high grade porcelain These are available from 32A and Rated voltage: 415V, 50Hz Standard: IS 2086:1993 121 Supply and fixing of Rewirable Fuse (Kit-Kat) with Fuse base & Fuse carrier are made of high grade porcelain These are available from 63 A and Rated voltage: 415V, 50Hz Standard: IS 2086:1993 122 Supply and fixing of Rewirable Fuse (Kit-Kat) with Fuse base & Fuse carrier are made of high grade porcelain These are available from 100A Rated voltage: 415V, 50Hz Standard: IS 2086:1993 123 Supply and fixing of Supply of HRC FUSE LINKS 6 to 35 Amp (DIN/BOLTED TYPE ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 124 Supply and fixing of Supply of HRC FUSE LINKS 45 to 63 Amps (DIN/BOLTED TYPE ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 125 Supply of 3 Core 2.5 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990.Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi) 126 Supply of PVC /cotton tape Role (8 Mtrs) 127 Supply of 12 / 15 MS plain rod fan hook 128 Supply of 19 / 20 mm Steel tube fan down rod 129 Supply of Concealed box PVC / MS with hook for fan 130 Supplyandfixing Ammeter selector switch 131 Supplyandfixing Voltmeter selector switch 132 Supplyandfixing 400mm High speed pedestal fan Oscilating 133 Supplyandfixing6A, flush type Neon Indicator 134 WORK ITEMS ( cotractor has to execute the work items on his own arrangements) 135 Supplyandfixing Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit) 136 Supplyandfixing Supply and fixing of MS stand for fixing outdoor unit 137 Supplyandfixing Supply and filling of R-22 Refrigerant Gas 138 Supplyandfixing Supply and fixing of Copper Refrigerant Piping of 7/8” dia 139 Supplyandfixing Supply and fixing of water drain pipe line (1” PVC Pipe) 140 Supplyandfixing Supply and providing of pipeline nitrle rubber insulation for Refrigerant and drain pipe lines 141 Supplyandfixing SUPPLY AND FILLING REFRIGERANT GAS R410A 142 Supplyandfixing 6 Metre Length Single Bracket Pole with Base Plate (250 x250 x6mm)76.10mm OD x 3.65mm Thick x 6000mm Length 143 Supplyandfixing 6 Metre Length Double Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length 144 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 145 3 x 1.5 sq. mm 146 3 x 2.5 sq. mm 147 3 x 4 sq. mm 148 3 x 6 sq. mm 149 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 150 20 mm 151 25 mm 152 32 mm 153 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 154 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 155 Upto 35 sq. mm 156 above 35 sq.mm and upto 95 sq.mm 157 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 158 Upto 35 sq. mm (clamped with 1mm thick saddle) 159 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 160 Supply and transportation of following XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt 161 10Sq mm X 4 core 162 16 Sq mm X 4 core 163 25 Sq mm X 3.5 core 164 35Sq mm X 3.5 core 165 50 Sq mm X 3.5 core 166 Fabrication ,transportation and and supply of wall mounted control panelboard of size 600x600x250mm made of 18 SWG CRCA sheet steel enclosure, 14 SWG mounting plate for cable entry fabricated , painted with two coats of Red oxide primer and two coats of Grey paint, lock andkey arrangements two side louvres with weld mesh inside etc., complete consisting of the following equipment with all internal wiring using L&T /Finolex copper FRLS cables of suitable size and capacity and cable clamp etc complete for 3 phase motor pump sets.Makes: Voltmeter ;. Makes: L&T / C&S / SALZAR / HPL/ AEI / Meco / Rishab; Ammeter Makes: L&T / C&S / SALZAR / HPL/ AEI / Meco / Rishab ; Single phase preventor Makes: L&T / Minilec / Powertec.32 A TP, 10KA MCB. Makes: Legrand / Schneider capacitor Makes: L&T / Siemens / Schneider / Epcos/Havells 167 Voltmeter ; 0-500 V 96x96mm size. 168 0 to 20 Amps / 0 50 Amps Ammeter (96x96mm size)-1No. 169 Single phase preventor of suitable range - 1No. 170 32 A TP, 10KA MCB. - 1No 171 Indication lamps (R-Y-B) with switch control - 1set 172 Voltmeter & Ammeter selector switch - 2 Nos 173 Supply and fixing of ISI Mark suitable capacitor 174 Upto 7.5 HP with DOL Starter of. 175 Providing Pressure testing of entire system withNitrogen and vacuuming nitrogen for all indoor and outdoor units. The pressure testing shall be done as per OEM recommendation. 176 Supply and fixing of 4.0 KVA 1-phase, automatic Electronic Voltage Stabilizer.Makes:V-Guard / Real Guard / Uni Stab / ITL 177 Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with E class insulation material and making connections etc. asrequired. (New model ceiling fan) 178 900/1200 mm sweep 179 Charges for oiling, greasing, overhauling of ceilingfan, table fan, pedestal fan irrespective to the size offan including removing, refixing of fan from site andtesting etc. as required 180 Providing and Replacement of ball bearing of ceiling/exhaust fan as required. (NBC/ SKF) 181 Providing and Replacement of Gun metal bush ofceiling/ exhaust/cooler fan/ as required. 182 Spray painting of ceiling fan of size 900/1200/ 1400mm with two coats of white/ brown enameled paintafter cleaning with sandpaper. Filling etc. as required. 183 Rewinding of Heavy-duty Exhaust fan motor including all necessary material, The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with E class insulation material and making connections etc. as required. 184 300/ 380 mm sweep 185 Rewinding of 400 mm table fan/pedestal fan motor including all necessary material, the motor is to bewound taking no. of coils, turns and pitch as it was originally wound with required size super enameledwire with E class insulation material and makingconnections etc. as required. 186 Rewinding of three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original withrequired size of super enameled wire E class insulation material and testing etc. as required make it in perfect working condition. 187 3.0 H.P. 188 5.0 H.P. 189 7.5 H.P. 190 Supply and charging of fresh refrigerant and testing ofperformance of air conditioner/ fridge/ water cooler of following capacity including capillary and strainer/ filter. 191 1.0 TR Window/ Split A.C 192 1.5 TR Window/ Split A.C 193 2.0 TR Window/ Split A.C 194 Supply and fixing of 230V/ 275V, 50Hz rating ………. 195 Starting capacitor 196 20-60 micro farad 197 80-150 micro farad 198 Running capacitor 199 2.5/3.15/4.0/6.0 micro farad 200 8.0 micro farad 201 10.0 micro farad 202 15.0 to 36.0 micro farad 203 Supply, Fabrication of 1set MS bracket suitable forfixing outdoor unit of split AC unit. 204 Air filter suitable for 1.50 Ton Split A.C. UnitP.V.C. / NYLON. 205 Fan blade for 1.0 / 1.5 Ton A.C. Machine. 206 Installation of Split Air Conditioners. 207 Removing of existing Split Air Conditioners without damaging to copper pipe. 208 Repairs and Installation of existing PCB in 1.0 / 1.5 /2.0 Ton Split A.C. Unit 209 Overhauling and servicing the Split type 1.5/2.0 Ton A.C. Machine by Cleaning the condenser cooling Coil etc., by blower and oiling the Fan Motor and Cleaning all parts and putting the machine in working condition. 210 Fabrication, Transportation and supply of 1.0 Mtr Length Single Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. (The design should be approved from field Engineers)POLE BRACKETS 211 Supply of 155 X 210 X 92 Sizes thermo-plastic cable junction boxes with IP66/67 weatherproof, for outdoor installation with knockouts for cable entry including terminals etc., complete (sizes in mm).Make : Hensel/Sadhrish 212 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 213 Refilling-6 Kg ABC Stored Pressure type Fire Extinguisher IS 2190 Incluing tranportation and Refixing in good condition with Re-filled & expired dates etc.. as directed by Engineer In-charge 214 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings):old fans 215 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings:Steel 216 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings):Aluminium 217 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings):Staineless Steel 218 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings:Iron 219 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings):Chrome Plated Brass fittings 220 Attending day to day repairs and maintenance works as per complaint register and Preventive maintenance checklist of Electrical installation as per electrical standerds 221 Engaging an Electrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, UG cables, DG Setetc complete all as directed by the Engineer-in-charge. (3 nos Electrician- Skilled) 222 Engaging an Electrician 223 Engaging an Electrician 224 Engaging an Electrician 225 Helper toElectrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, OH lines, UG cables etc complete all as directed by the Engineer-in-charge. ( 1 nos Un Skilled)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
30.
Banking and Finance #10242687 Price Bid
Tender For Arm Electrical Works To Esi Hospital Staff Quarters At Thathaneri And Sivakasi In Madurai Region.; 1 Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 2 Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 3 Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 4 Supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 5 Supply of 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable 6 Supply of 20 mm iron staples/ saddles/ screws 7 Supply of 25 mm iron staples/ saddles/ screws 8 Supply of 20 mm dia. ISI marked, PVC conduit 9 Supply of 25 mm dia. ISI marked, PVC conduit 10 Supply of 32 mm dia. ISI marked, PVC conduit 11 Supply of 20 mm PVC bends 12 Supply of 25 mm PVC bends 13 Supply of 20 mm PVC couplers 14 Supply of 25 mm PVC couplers 15 Supply of 20 mm PVC junction box, one way 16 Supply of 20 mm PVC junction box, two way 17 Supply of 75 mm X 75 mm X 50 mm PVC box 18 Supply of Modular GI box for 2 module 19 Supply of Modular GI box for 3 module 20 Supply of Modular GI box for 4module 21 Supply of Modular GI box for 6 module 22 Supply of Modular GI box for 8 module 23 Supply of Modular GI box for 12 module 24 Supply of 3 mm thick phenolic laminated sheet 25 Supply of Ceiling rose, 3 pin, 5 amps ISI marked 26 Supply of S.P. 5/6 amps, one way modular switch, ISI marked 27 Supply of S.P. 15/16 amps, one way modular switch, ISI marked 28 Supply of 3 pin 5/6 amps modular socket outlet, ISI marked 29 Supply of 6 pin 15/16 amps modular socket outlet, ISI marked 30 Supply of Modular bell push, ISI marked 31 Supply of Stepped type Modular Fan regulator (2 module) 32 Supply of Modular blanking plate 33 Supply of 6 pin 25 amp modular type socket ISI Marked 34 Supply of Modular base & cover plate for 1 module 35 Supply of Modular base & cover plate for 2 module 36 Supply of Modular base & cover plate for 3 module 37 Supply of Modular base & cover plate for 4 module 38 Supply of Modular base & cover plate for 6module 39 Supply of Modular base & cover plate for 8module 40 Supply of Modular base & cover plate for 12module 41 Supply of S.P. 5/6 A, one way switch, piano type ISI marked 42 Supply of S.P. 5/6 A, two way switch, piano type ISI marked 43 Supply of S.P. 15/16 A, one way switch, piano type ISI marked 44 Supply of 3 pin 5/6 A socket outlet, piano type ISI marked 45 Supply of 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked 46 Supply of Bell push, piano type 47 Supply of Call bell/ buzzer, single phase 48 Supply of PVC Batten/Angle Holder 49 Supply of 32 amps. TPN, switch disconnecter fuse unit (Panel mounted type) with ISI marked HRC fuses 50 Supply of 63 amps. TPN, switch disconnecter fuse unit (Panel mounted type) with ISI marked HRC fuses 51 Supply of 100 A, TPN, switch disconnecter fuse unit (Panel mounted type) with ISI marked HRC fuses 52 Supply of 6 amps. to 32 amps. ratings , SP MCB, C curve, 10 KA breaking capacity 53 Supply of 6 amps. to 32 amps. ratings , SPN MCB, C curve, 10 KA breaking capacity 54 Supply of 6 amps. to 32 amps. ratings , DP MCB, C curve, 10 KA breaking capacity 55 Supply of 6 amps. to 32 amps. ratings , TP MCB, “C” curve,10 KA breaking capacity 56 Supply of 6 amps. to 32 amps. ratings , TPN MCB, “C” curve,10 KA breaking capacity 57 Supply of Single pole, Blanking plate 58 Supply of 40 amps., 4 pole isolator 59 Supply of 63 amps., 4 pole isolator 60 Supply of 25 amps. rating, 2 pole RCCB, 30mA 61 Supply of 40 amps. rating, 2 pole RCCB, 30mA 62 Supply of 63 amps. rating, 2 pole RCCB, 30mA 63 Supply of 20 amps. SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure 64 Supply of 20 amps. TPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure 65 Supply of 4 way (4+12), TPN, MCB DB, double door,horizontal type 66 Supply of 6 way (4+18), TPN, MCB DB, double door,horizontal type 67 Supply of 8 way (4+24), TPN, MCB DB, double door, horizontal type 68 Supply of Brass compression gland for (28 mm) 4 X 16 sq. mm 1.1 KV grade cable 69 Supply of Brass compression gland for (28 mm) 3½ X 25 sq. mm 1.1 KV grade cable 70 Supply of Brass compression gland for (32 mm) 3½ X 35 sq. mm 1.1 KV grade cable 71 Supply of Brass compression gland for (35 mm) 3½ X 50 sq. mm 1.1 KV grade cable 72 Supply of Brass compression gland for (38 mm) 3½ X 70 sq. mm 1.1 KV grade cable 73 Supply of Aluminium lugs for 6 sq. mm cable 74 Supply of Aluminium lugs for 10 sq. mm cable 75 Supply of Aluminium lugs for 16 sq. mm cable 76 Supply of Aluminium lugs for 25 sq. mm cable 77 Supply of Aluminium lugs for 35 sq. mm cable 78 Supply of Aluminium lugs for 50 sq. mm cable 79 Supply of Aluminium lugs for 70 sq. mm cable 80 Supply of Aluminium lugs for 95 sq. mm cable 81 Supply of Aluminium lugs for 120 sq. mm cable 82 Supply of Aluminium lugs for 150 sq. mm cable 83 Supply of Aluminium lugs for 185 sq. mm cable 84 Supply of Aluminium lugs for 225 sq. mm cable 85 Supply of Aluminium lugs for 240 sq. mm cable 86 Supply of Aluminium lugs for 300 sq. mm cable 87 Supply of 16 mm X 50 mm bolts and nuts with washers 88 Supply of 16 mm X 125 mm bolts and nuts with washers 89 Supply of Steel fastener 6 mm X 75 mm 90 Supply of Steel fastener 8 mm X 75 mm 91 Supply of PVC fastener 40mm long 92 Supply of PVC clip for fixing cable 93 Supply of Rubber/ PVC bushes 94 Supply of 6 mm dia rivet/ stud/ bolts and nuts 95 Supply of 25mm X 3mm bolts & nuts 96 Supply of 32mm X 8mm bolts & nuts 97 Supply of 38mm X 10mm bolts & nuts 98 Supply of 38 mm X 7 mm, bolts and nuts 99 Supply of 15 mm long X 6 mm dia G.I. bolts and nuts 100 Supply of 10 mm X 25 mm long G.I. bolt with nut etc 101 Supply of 16 mm X 50 mm bolts and nuts with washers 102 Supply of 16 mm X 40 mm bolts and nuts with washers 103 Supply of 16 mm X 125 mm bolts and nuts with washers 104 Supply of 16 mm X 150 mm bolts and nuts with washers 105 Supply of 10 mm X 25 mm long tinned brass bolt with nut etc. 106 Supply of GI saddles 19mm x 0.55mm for conduit 107 Supply of GI saddles 25mm x 0.90mm for conduit above 25mm 108 Supply of 250 mm X 200 mm H.T. danger notice plate 109 Supply of 200 mm X 150 mm M.V. danger notice plate 110 Supply of Coke 111 Supply of Salt 112 Supplyandfixing of 4’ 18W Crystal Glass LED Tube Light Fitting 113 Supplyandfixing 7W / 9W LED Bulb 114 Supplyandfixing 15W LED Bulb 115 Supplyandfixing 30W LED Street Light Fitting with LED 116 Supplyandfixing 48W LED Street Light Fitting with LED 117 Supplyandfixing 36 / 40W Electronic Ballast for Flourescent Tube 118 Supplyandfixing Water Tight Bulk Head Fitting suitable for 100 / 60 Watts Lamp with Guard Heavy Type 119 Supplyandfixing Ceiling Rose 120 Supplyandfixing Call Bell / Buzzer 6mm suitable for AC / DC 121 Supplyandfixing Push Bell 122 Supplyandfixing AC Ceiling Fan complete 1200 mm (48”) Sweep with 300mm Down Rod (without Regulator) 123 Supplyandfixing Stepped Electronic 300W / 450W Square Type FanRegulator 124 Supplyandfixing Dimmer Type Electronic 300W / 450W Square Type Fan Regulator 125 Supplyandfixing AC Exhaust Fan 225mm (9”) Sweep (Light Duty) 126 Supplyandfixing AC Exhaust Fan 300mm (12”) Sweep (Light Duty) 127 Supplyandfixing AC Exhaust Fan 300mm (12”) Sweep (Heavy Duty) 128 Supplyandfixing AC Exhaust Fan 450mm (18”) Sweep (Heavy Duty) 129 Supplyandfixing MS / Fibre Louvers Shutters arrangements for 300mm AC Exhaust Fan 130 Supplyandfixing MS / Fibre Louvers Shutters arrangements for 375mm AC Exhaust Fan 131 Supplyandfixing MS / Fibre Louvers Shutters arrangements for 450mm AC Exhaust Fan 132 Supplyandfixing 48” Ceiling Fan 5 Star Rated (without Regulator) HIGHER END 133 Supplyandfixing 300mm Sweep WALL MOUNTING FAN 134 Supplyandfixing SURFACE MOUNTING BOXES (PLASTIC) - HIGHER END 135 Supplyandfixing Surface Box - 1/2 Module 136 Supplyandfixing Surface Box - 3 Module 137 Supplyandfixing Surface Box - 4 Module 138 Supplyandfixing Surface Box - 6 Module 139 Supplyandfixing Surface Box - 8 Module 140 Supplyandfixing Surface Box - 8 (2 row x 4) Module 141 Supplyandfixing Metal Surface Box - 12/16 (2 row x 6) Module 142 Supplyandfixing Metal Surface Box - 18 Module 143 Supplyandfixing 5 Amps 3 Pin & 2 Pin Combined Flush Type Wall Socket only 144 Supplyandfixing 5 Amps / 15 Amps 3 Pin Flush Type Wall Socket only 145 Supplyandfixing 5 Amps 3 Pin Top 146 Supplyandfixing 15 Amps Flush Type Switch 147 Supplyandfixing 10 Amps MC Plug with 3 Pin Top 148 Supplyandfixing 20 Amps MC Plug with 3 Pin Top 149 Supplyandfixing 25A Flush type Wall Socket with 25A DP MCB for AC Plug 150 Supplyandfixing6A, flush type Neon Indicator 151 Supply of PVC /cotton tape Role (8 Mtrs) 152 Supply of 12 / 15 MS plain rod fan hook 153 Supply of 19 / 20 mm Steel tube fan down rod 154 Supply of Concealed box PVC / MS with hook for fan 155 LEGEND PLATES 156 Danger Notice Plates of size 1982 -, shall comply with IS:2551- 157 250x200mm, 158 200x150mm, 159 150x100mm, 160 Supply and fixing of Rewirable Fuse (Kit-Kat) with Fuse base & Fuse carrier are made of high grade porcelain These are available from 32A and Rated voltage: 415V, 50Hz Standard: IS 2086:1993 161 Supply and fixing of Rewirable Fuse (Kit-Kat) with Fuse base & Fuse carrier are made of high grade porcelain These are available from 63 A and Rated voltage: 415V, 50Hz Standard: IS 2086:1993 162 Supply and fixing of Rewirable Fuse (Kit-Kat) with Fuse base & Fuse carrier are made of high grade porcelain These are available from 100A Rated voltage: 415V, 50Hz Standard: IS 2086:1993 163 Supply and fixing of Supply of HRC FUSE LINKS 6 to 35 Amp (DIN/BOLTED TYPE ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 164 Supply and fixing of Supply of HRC FUSE LINKS 45 to 63 Amps (DIN/BOLTED TYPE ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 165 Supply of 3 Core 2.5 Sqmm with ISI marked Flat Copper cable of ISI for Submersible Motors confirming to IS: 694:1990. Makes:Finolex/RRKabel/Polycab/Havells/KEI/ Gloster/ Goldmedal / GM/ Finecab/ Million/ APAR(Anushakthi) 166 WORK ITEMS ( cotractor has to execute the work items onhis own arrangments) 167 Supplyandfixing Supply and laying of 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit) 168 Supplyandfixing Supply and fixing of MS stand for fixing outdoor unit 169 Supplyandfixing Supply and filling of R-22 Refrigerant Gas 170 Supplyandfixing Supply and fixing of Copper Refrigerant Piping of 7/8” dia 171 Supplyandfixing Supply and fixing of water drain pipe line (1” PVC Pipe) 172 Supplyandfixing Supply and providing of pipeline nitrle rubber insulation for Refrigerant and drain pipe lines 173 Supplyandfixing 6 Metre Length Single Bracket Pole with Base Plate (250 x250 x6mm)76.10mm OD x 3.65mm Thick x 6000mm Length 174 Supplyandfixing 6 Metre Length Double Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length 175 Supplyandfixing 400mm High speed pedestal fan Oscilating 176 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 177 3 x 1.5 sq. mm 178 3 x 2.5 sq. mm 179 3 x 4 sq. mm 180 3 x 6 sq. mm 181 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 182 20 mm 183 25 mm 184 32 mm 185 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 186 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 187 Upto 35 sq. mm 188 above 35 sq.mm and upto 95 sq.mm 189 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 190 Upto 35 sq. mm (clamped with 1mm thick saddle) 191 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 192 Supply and transportation of following XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I U.G. CABLESMakes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt 193 10Sq mm X 4 core 194 16 Sq mm X 4 core 195 25 Sq mm X 3.5 core 196 35Sq mm X 3.5 core 197 50 Sq mm X 3.5 core 198 Fabrication ,transportation and and supply of wall mounted control panelboard of size 600x600x250mm made of 18 SWG CRCA sheet steel enclosure, 14 SWG mounting plate for cable entry fabricated , painted with two coats of Red oxide primer and two coats of Grey paint, lock andkey arrangements two side louvres with weld mesh inside etc., complete consisting of the following equipment with all internal wiring using L&T /Finolex copper FRLS cables of suitable size and capacity and cable clamp etc complete for 3 phase motor pump sets.Makes: Voltmeter ;. Makes: L&T / C&S / SALZAR / HPL/ AEI / Meco / Rishab; Ammeter Makes: L&T / C&S / SALZAR / HPL/ AEI / Meco / Rishab ; Single phase preventor Makes: L&T / Minilec / Powertec.32 A TP, 10KA MCB. Makes: Legrand / Schneider capacitor Makes: L&T / Siemens / Schneider / Epcos/Havells 199 Voltmeter ; 0-500 V 96x96mm size. 200 0 to 20 Amps / 0 50 Amps Ammeter (96x96mm size)-1No. 201 Single phase preventor of suitable range - 1No. 202 32 A TP, 10KA MCB. - 1No 203 Indication lamps (R-Y-B) with switch control - 1set 204 Voltmeter & Ammeter selector switch - 2 Nos 205 Supply and fixing of ISI Mark suitable capacitor 206 Upto 7.5 HP with DOL Starter of. 207 Providing Pressure testing of entire system withNitrogen and vacuuming nitrogen for all indoor and outdoor units. The pressure testing shall be done as per OEM recommendation. 208 Supply and fixing of 4.0 KVA 1-phase, automatic Electronic Voltage Stabilizer.Makes:V-Guard / Real Guard / Uni Stab / ITL 209 Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turnsand pitch as it was originally wound with required size super enameled wire with E class insulation material and making connections etc. as required. (New model ceiling fan) 210 900/1200 mm sweep 211 Charges for oiling, greasing, overhauling of ceiling fan, table fan, pedestal fan irrespective to the size of fan including removing, refixing of fan from site and testing etc. as required 212 Providing and Replacement of ball bearing of ceiling/ exhaust fan as required. (NBC/ SKF) 213 Providing and Replacement of Gun metal bush ofceiling/ exhaust/cooler fan/ as required 214 Spray painting of ceiling fan of size 900/1200/ 1400 mm with two coats of white/ brown enameled paint after cleaning with sandpaper. Filling etc. asrequired. 215 Rewinding of Heavy-duty Exhaust fan motor including all necessary material, The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with E class insulation material and making connections etc. as required. 216 300/ 380 mm sweep 217 450 mm sweep 218 Rewinding of 400 mm table fan/pedestal fan motorincluding all necessary material, the motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enameled wire with E class insulation material and making connections etc. as required. 219 Rewinding of three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire E class insulation material and testing etc. as required make it in perfect working condition. 220 3.0 H.P. 221 5.0 H.P. 222 7.5 H.P. 223 10.0 H.P 224 Supply and charging of fresh refrigerant and testing ofperformance of air conditioner/ fridge/ water cooler of following capacity including capillary and strainer/ filter. 225 1.0 TR Window/ Split A.C 226 1.5 TR Window/ Split A.C 227 2.0 TR Window/ Split A.C 228 Supply and fixing of 230V/ 275V, 50Hz rating ………. 229 Starting capacitor 230 20-60 micro farad 231 80-150 micro farad 232 Running capacitor 233 2.5/3.15/4.0/6.0 micro farad 234 8.0 micro farad 235 10.0 micro farad 236 15.0 to 36.0 micro farad 237 Supply, Fabrication of 1set MS bracket suitable forfixing outdoor unit of split AC unit. 238 Air filter suitable for 1.50 Ton Split A.C. UnitP.V.C. / NYLON. 239 Fan blade for 1.0 / 1.5 Ton A.C. Machine. 240 Installation of Split Air Conditioners. 241 Removing of existing Split Air Conditioners without damaging to copper pipe. 242 Repairs and Installation of existing PCB in 1.0 / 1.5 /2.0 Ton Split A.C. Unit 243 Overhauling and servicing the Split type 1.5/2.0 Ton A.C. Machine by Cleaning the condenser cooling Coil etc., by blower and oiling the Fan Motor and Cleaning all parts and putting the machine in working condition. 244 Fabrication, Transportation and supply of 1.0 Mtr Length Single Arm Bracket made with MS galvanized 40mm / 50mm dia Pipe. (The design should be approved from field Engineers)POLE BRACKETS 245 Supply of 155 X 210 X 92 Sizes thermo-plastic cable junction boxes with IP66/67 weatherproof, for outdoor installation with knockouts for cable entry including terminals etc., complete (sizes in mm).Make : Hensel/Sadhrish 246 Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required.Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec 247 Analog type (96 mm x 96 mm) 248 Digital type 249 Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.Make: Conzerve/Elmeasure/Meco/HPL /L&T/ socomec 250 Analog type (96 mm x 96 mm) 251 Below 500 A 252 Above 500A 253 Digital type 254 Below 500 A 255 Above 500 A 256 Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required 257 Red/yellow/Green colour 258 Blue colour 259 Supply and fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Make:Seimens/ ABB/ Schneider/L&T/C&S/HPL 260 Non-luminous type 261 Luminous type 262 Carryout routine maintenance, servicing and testing of 630A to 1500A L.T.ACB by cleaning fixed contacts, moving contacts and arc chutes including servicing and putting the ACB in perfect working condition after setting all relay and ON, OFF mechanism etc., done with only manufacturing companies or OEM authorized 263 Carryout routine maintenance and servicing of LT.Cubical panel board having approximately 15 to 22 Nos of switches cleaning with power blower and servicing the contacts, tightening the connection ofincoming and outgoing cables, and checking the operating mechanism for smooth functioning of switches and putting them in smooth workingcondition. 264 Routine maintenance of transformer, includingtesting of insulation resistance, oil breakdownstrength. Reconditioning / replacement of silica zel,cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). 265 Testing of Transformer oil for dielectric breakdown strength. 266 Replacing old and unserviceable gasket of top cover plate of transformer having following capacity. -………… 267 up to 315 KVA 268 500 / 1000 KVA 269 Painting to transformer with 2 coats Zinc chromate red oxide duly scraping existing paint followed by 2 coats of hammer ton grey paint etc.,complete. -………. 270 Upto 500 KVA 271 630 / 1000 KVA 272 Supply of new and tested transformer oil as per IS-335 - 1972 (per Ltr) 273 Filtration of transformer oil as per ISS specifications filters to dielectric strength above 40KV ……. 274 at site. (Per Ltr) excluding transportation 275 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 276 Refilling-6 Kg ABC Stored Pressure type Fire Extinguisher IS 2190 Incluing tranportation and Refixing in good condition as directed by Engineer In-charge 277 Refilling- 4.5Kg CO2type Fire Extinguisher as per IS 2190 Incluing tranportation and Refixing in good condition as directed by Engineer In-charge 278 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings):old fans 279 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings:Steel 280 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings):Aluminium 281 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings):Staineless Steel 282 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings:Iron 283 Credit for dismantled materials ( payment to be made to ESIC inliue of dismantled materials available while replacing with new fittings):Chrome Plated Brass fittings 284 Attending day to day repairs and maintenance works as per complaint register and Preventive maintenance checklist of Electrical installation as per electrical standerds 285 Engaging an Electrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings,UG cables, DG Setetc complete all as directed by the Engineer-in-charge. (2 nos Electrician- Skilled:Tataneri Hospital and2 nos Electrician- Skilled:Sivakasi Hospital ) 286 A. Helper 287 B. Helper 288 C. Helper 289 D. Helper 290 Helper toElectrician for day to day maintenance of Electricalworks like repairs to internal and external electricsupplyby replacing the worne out fittings/fixtures , reparing the unserviceable fittings/ fixtures such as switches, sockets, switch boards, LT Panels , MCBs, MCB DBs, MCCBs, SFUs FSUs etc andall types of fans/ light fittings, UG cables etc complete all as directed by the Engineer-in-charge. ( 2 nos Un Skilled) (1 nos Helper :Tataneri Hospital and1 nos Helper:Sivakasi Hospital ) 291 A. Helper 292 B. Helper
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
31.
Housing Urban and Rular Development #10235078 Price Bid
Tender For New Construction Of Cheriyan Nagar Library Chennai; 1 DISMANTALING WORKS 2 Dismantling etc., all complete 3 Brick / Stone Masonry in lime mortar walls 4 Dismantling RCC by manual / by using deploying machineries 5 Doors and Windows including removal of frames, hinges and fastenings 6 CIVIL WORK 7 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size bouldersand Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete SS.20B 10 cum 8 Carting away surplus excavated earth available with in the campus is to be carted to a lead of within 40 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 9 Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 10 Supplying and filling in foundation, basement, etc with filling Gravel inwellrammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 12 Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls.The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide “Chloripyrifos” and sprayingthe same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II) / 1981 and as directed by the departmental officers. 13 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc.,Rate to include all materials, labour charges, wastages ,placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by theClient / Engineer-in-charge. 14 For Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members 15 for plane surfaces such as rectangular or square rcc columns, sunshades, topand bottom slab of rcc boxing, etc. 16 Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members 17 Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box binders basement retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. 18 For FoundationandBasement 19 For Ground Floor 20 For First Floor 21 For Second Floor 22 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required.Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 23 Supply and constructing Fly ash Brick (230 x 110 x 75mm) masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure usingFly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 24 For Ground Floor 25 For First Floor 26 For Second Floor 27 Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails. 28 Upto 3 M Height 29 3 m to 5.5 m Height 30 5.5 m to 7.5 m Height 31 7.5 m to 10 m Height 32 10 m to 12.5 m Height 33 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 34 Plastering 15 mm thick for external surfaces with Cement Mortar 1:5 (1 of cement : 5 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate includingcost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 35 Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine river sand)according to specifications. Rate shall include for providing GI chicken mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 36 Painting the new plastered walls with two coats for Interior Plastic Emulsion paint approved quality and colour over a priming coat, with two coats of wall putty including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 37 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 38 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work 39 UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chamberedsections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer before use on work 40 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 41 Painting the new Iron work with two coats of Ready Mixed Enamel Paint of aproved quality and colour over the existing priming coatincluding the cost all materials etc.,complete, in all floors and as directed by the Departmntal Officers. 42 Providing and fixing Vertical blinds , quality of approved make fabric made of 100% polyester woven fabric thickness 0.40mm with virtually maintenance free having plastic bottom chain thickness of chain-0.50mm and diameter-3mm, Plastic with metal bottom and suitable coating on exterior, including all fixtures and fittings complete in all respect as per design/color/shade including requisite installation brackets etc as required for installation at site with anchoring arrangements complete. 43 Supply and laying with best quality the following materials of Ruby Red, Raw Silk Granite Slabs (Super Fine Polished with Machine Cut Edges) of sizes 4’x2’ and above 18mm to 20mm thick Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 44 Supply and laying with best quality the following materials of Sinthetic Grey, Paradise and similar varieties Granite Slabs Granite Tiles - (Superfine Polished with Machine Cut Edges) of size 2’0” x 1’0” and above 10mm Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 45 Nosing for Granite Slab-Single Nosing 46 Grooving the Granite Slab 47 Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Executive Engineer before use on work 48 Paving the floor with design Antiskirt Ceramic tiles (colour and shade as directed) of size 305 mm x 305 mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement. 49 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 50 Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 of approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Naterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc Rate including all mater aaod and lifts, working materials, labour charges wastages with necessary lead and at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specificatior and as directed by the Client/ Engineer-in Charge 51 Including applying two coats not less than 2 nm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No. 1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 52 Waterproofing: Providing and Applying CFTRI approvedtwo component flexible polymer modified acryliccementitious waterproofing coating with a mix ratio of(5 Liquid :7 Powder) to the RCC surface of the UGT/OHT tankapplied @ 2.2kg/m2 in 2 coats to achieve1.2mm DFT, having Elongation at break >120% asper ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right anglesof wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completelyas per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applyingtwo component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification 53 Finishing the top of roof with one course of Solar Reflective ceramic tiles of size 305 mm x 305 mm x 7 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 54 Supplying And Fixing Rubber Moulded Interlocking Paver Blocks Against Available Edge Restraints 83 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro- Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To- Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (M Sand)) 55 Supplying and fabricating of MS structural steel supports for various applications using channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above. 56 Providing Teak wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. 57 Best Indian Teak Wood Panelled door in double shutters with frames 100x75mm at side,verticals and top. The shutters shall beof 40mm thick with moulded panels in 20mm thick planks,6Nos.of iron hold fasts fixed in c.c.1:2:4 6Nos.of butt hinges 125mm long including wind appliances, furniture,iron fittings,1No.of iron padlock 15cm long for locking arrangements and fixing inposition,etc.,complete.(ISI STD) 58 Varnishing the new wood work one coat with best shellac and with fine best varnish of approved quality varnish of teak wood natural finish including preparation of surfaces with sand papering in patty priming etc., complete complying with standard specification and as directed by the Departmental officers. 59 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 60 Best Indian Teak Wood panelled door shutter for single leaf door. The shutter shall be 40mm thick with moulded panels in 20mm thick planks inclusive of 3 Nos.butt hinges 125mm long,furniture iron fittings,1No.of jappened hooks and eyes 200mm long and 6mm thick and iron pad lock 15cm long including fixing inposition,etc.,complete 61 FALSE CEILING WITH GYPSUM PLAIN TILES Providing and fixing true horizontal level false ceiling using SAINT -GOBAINGYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at1200mm c/cmax by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm (Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying 62 Art work as per the direction of department official, over Oil Painting with first class quality and approved colour including a priming coat with thorough scrapping clean removal of dirt., etc., complete and including necessary plaster of paris, putty, etc., wherever required (Relevent ISI STD), including putty works. 63 Supplying and Fixing of English Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 64 Supplying and Fixing of Tamil Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 65 upplying and Fixing ofEmblem (15”) Stainless Steel size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 66 Supply and fixing of Pre-fabricated Structural Steel, coated galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Panel shall have 1020 mm effective width, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidental charges. 67 Supplying and erecting in position LIGHT DUTYSTEEL TRUSSES as per the drawing.The materials and design of the trusses should confirm to the relevant Indian Standard specification.The trusses shall be procured only from reputed manufactures oftrusses with prior approval of the Buildings Engineer and a certificate to the effect from the reputed manufacturers shall also be furnished with design.The rate quoted shall include the cost oftrusses.Base-plate with holding down bolts and nuts to RCC or Masonry works, roof purlins, rafters, purlin sleeves, the members fixing accessories etc., painting one coat of red-oxide paint and erecting in position etc., complete as directed during execution. The contractor shall also arrange to provide grouting for holding down bolts embeding the end purlins, to the gable wall wherever necessary etc.,The roof sheeting shall project 0.762m from the eves purlins. 68 Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. 69 Providing, supplying, and fixing factory-manufactured pre-fabricated insulated roofing panels made of PUF (Polyurethane Foam) sandwiched between two metal skins, comprising pre-painted galvanized iron (PPGI) sheets of 0.5 mm thickness on both sides with 40 mm to 50 mm thick CFC-free polyurethane foam core of minimum density 40 kg/m³, having tongue and groove jointing with cam-locking arrangement for weather-tight sealing. Panels shall have minimum overall R-value of 6.5 and thermal conductivity not more than 0.022 W/m·K. Roofing to be supported over structural purlins/trusses using self-drilling screws with EPDM washers, sealants, fasteners, ridge covers, and flashing, complete. Rate includes supply, transport, hoisting, cutting to size, edge finishing, foam taping at joints, sealing, labour, tools, scaffolding, and all incidentals for a fully finished, insulated, and weatherproof roofing system as per manufacturer’s specification and as directed by the Engineer-in-Charge. 70 Brick Wall Cladding Nuvocotto Edge Cut Wall Tiles Natural Red finish in size 230mm x 76mm x 15mm 71 Brick JalliNuvocotto Camp Jallie Natural Red finish in size 200mm x 200mm x 60mm 72 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 73 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 74 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 75 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 76 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 77 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 78 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 79 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,. 80 PLUMBING 81 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, unioncoupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting. 82 Supplying and fixing Stainless Steel Health Faucetwith all the accessories etc, 83 Supply and fixing White without PedastalWash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia B Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples,15mm CP Pillar Tap etc (The wash basin should be got approved by Executive Engineer before use on works). 84 Providing and fixing C.P. Angle stop cock of approved quality conformingto IS:8931 :15mm nominal bore 85 Providing and fixing Brass Chromium Plated Towel Rail 60cm long and20mm dia with Brackets etc,. 86 Providing and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm 87 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines. 88 75 DIA 89 110 DIA 90 Providing, fixing and testing of PVC waste pipe of agricultural sereis conforming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. 91 40 DIA 92 Providing, fixing and testing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (100 mm x 75 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Concealed On Wall) 94 20MM DIA 95 25MM DIA 96 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 97 25mm dia Cost of gate valve 98 32mm dia Cost of gate valve 99 Providing, installation, testing and commissioning approved make CIY-type Strainer conforming to IS standardwithnecessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications. 100 32 mm nominal bore 101 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.(Pipes Runningin the Shaft & below ground level) 102 75 DIA 103 110 DIA 104 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Pipes Runningin the Shaft & below ground level) 105 25MM DIA 106 32MM DIA 107 Providinging and fixing in position PVC Vent cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 108 75MM DIA 109 110MM DIA 110 Providing and fixing GI. puddle flanges (IS; 1239) fabricated out of 6 mmthick M.S. plate of size 300 x 300mm plusdia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.(Rate As per Quotation) 111 32 mm dia 112 40 mm dia 113 50 mm dia 114 65 mm dia 115 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:(Rate As per Quotation) 116 Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 230 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internalfaces plastered smooth in CM1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600x600 mm size internal and depth will 450mm to 1200mm & 900x800 mm size internal and depth will 450mm to 1200mm. (Rate As per Quotation) 117 600x600 118 Making of core cutting in RC slab of maximum 150mm thick of following diameter. 119 a) 150 mm dia 120 b) 125 mm dia 121 Providing and fixing MS slotted angle iron brackets, hangers, MS grip bilts,universal clamps with thereaded rod,supports with necessary drilling holes to suit the insertion of pipe clamps, deburring etc., as per detailed drawing for supporting soil, waste and rain water pipes and water Providing pipes in shafts with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls/outer walls etc., The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08 mm thick conformed to IS 1239 etc., complete as directed by the employer. 122 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.(600x600mm) 123 Providinging, installing, fixing, jointing, testing and commissioning of PVC Storm water pipe confirming to IS 13592 of SWR quality 4 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste,The quoted rate shall include necessary earth work, fittings,pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting,refilling, and making good the same complete as required. 124 110 DIA 125 Providing, fixing and testing of Terrace Rain water outlet (110dia) with all the accessories etc,. 126 INTERIOR 127 BOOK SHELF 1 - 2100 x 400 x 2100 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 128 MAGAZINE HOLDER - 600 x 250 x 1200 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 129 DISPLAY UNIT AT RECEPTION - 1200 x 300 x 600 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 130 LEDGE 5000 x600 x 750 Panels are 16mm MR ply with 1mm Matt Finish on both sides with 2mm PVC Edge Band finish mounted to the wall. 131 4SEATERLEARNINGCENTRETABLE-2000mmx1000mmx750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thick 132 6SEATERLEARNINGCENTRETABLE-2400mmx1000mmx 750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thic 133 READING CHAIR - Lounge Chair Uphostered in EPU Leather. Sleek Four Star Fixed Base With Revolving Function In Warm White Powder Coated Finish. Three Dimensional Lumbar Support Design. Model number SCML-SF30.1. Bosses Cabin or equivalent. 134 ROLLINGCHAIRS-Medium back chair with metal grey back frame, metal grey adjustable PU armrest (4D), moulded foam seat with metal grey shell, STG drive-by-wire mechanism with 4 position locking, polished aluminum alloy five-star base with metal grey PU castors. Model number CHT66SW. Bosses Cabin or equivalent. 135 SINGLESTUDYCHAIR:Multi-Purpose Chair Upholstered In Water Based PU Leather. Cushioned Seat and White Ash Solid Wood Legs. Model number SCMF-XCB33 - Latte Brown. Bosses Cabin or equivalent. 136 LOCKER & FOOTWEAR STORAGE- – 1950x375x470mmPLU main 2 DR numeric lock with envelop slot – 1950x375x470mm. Godrej interio or equivalent. 137 RECEPTIONDESK-1800mmx650mmx 1050mm- Reception Table In Matt White and Oak Laminate. IncludesStorage Cabinet and WireManagement Grommet OnDesk. Top Model number 28ROB003(BCRMB-OB 03). Bosses cabin or equivalent. 138 Seamlessly shift from warm, cozy tones to cool, vibrant whites (also known as tunable white or human-centric lighting) is an advanced JS3 Serial LED Connecting System LED lighting technology that allows users to adjust the color temperature of the light output — from warm to cool — to suit mood, time of day, or functional needs.LED Type: OSRAM SMD 3030Iceil™ Supply of OSRAM 24V LED Module Color Temperature: 2700K to 10000K with Iceil IP67 Drivers CRI: ≥90 – Delivers natural, true-to-life color accuracyMounting: High-performance aluminum rigid PCB– Ensures excellent thermal management and long lifespanConfiguration:– Each block features 4 high-quality LEDs– Optimized light spacing for shadow-free illumination– Viewing Angle: PMMA lens Ultra-wide 160° beam spreadDimmable: No Compatibility:DALI, Tuya Smart App, Alexa, & Google Home. Touch Panel, and RF Remote control optionsPower Consumption:– Only 4-6W per sq.ft– Energy-efficient yet high-lumen outputLighting Quality:– Uniform light diffusion across the stretch ceiling– Suitable for both translucent and printed membrane typesIceil™ Power Supply: Wide Input Range 100-305AC (Class I), Surge Protection with 6KV/4KV, Working temp. -20~ +45°C 20% ~ 90%RH, Metal case IP67, Power factor <0.98LED and Power Supply Warranty: 5 Years or 50,000 Hours (whichever comes first)Certifications: CE & RoHS Certified – environmentally safe and globally compliant Installation of pre-supplied LED lighting fixtures, associated drivers, and control systems, including all necessary mounting, wiring, terminations, and system integration by qualified technicians.The scope includes:Installation of LEDs as per lighting layoutMounting and secure placement of LED drivers and control gear in accessible locationsElectrical connections between LEDs, drivers, and controllers using appropriate cablingTesting of each circuit and commissioning of the full lighting setupRate Includes: Skilled labor, tools, basic fasteners, and all on-site installation efforts.. 139 Iceil™ supplies exclusively premium-grade of European Standard PVC Thermo-Stretchable Membrane, complying with BS1-D0 as per EN 13501-1 and Class A as per ASTM E84-2024 fire safety standards. The membrane is precision-cut to the required shape and size, with perimeter edges high-frequency welded with harpoon inserts. Installation is carried out using a durable aluminium profile framing system, ensuring a seamless, secure, and aesthetic ceiling solutionThickness 0.18 mmWeight 250–300 gsm ± 2%Light Transmission Up to 75% (for translucent type)Width Up to 5 meters (seamless); larger areas joined with invisible seamsStretching Method Thermal installation at ~50–60°C using hot air gas blower Fire Rating BS1-D0, as per EN 13501-1, ASTM E84-2024 Class A Explanation: B = Very limited contribution to fire, s1 = Little or No Smoke Production, d0 = No flaming droplets or particles Moisture Resistance 100% Moisture-proofUV Resistance Yes – does not yellow or degrade indoorsEnvironmental ROHS compliant, Phthalate-free, UL Certified - Tri-O-cresyl phosphate < 50mg per kgCertification Manufactured in ISO 9001:2015 certified factoryWarranty 10 Years (under standard indoor conditions) Installation of pre-supplied Stretch Ceiling System, including site preparation, profile fixing, membrane stretching, and finishing using specialized tools and skilled labor.The scope includesFixing of aluminum/PVC perimeter profiles as per approved ceiling layoutHeating and stretching of the pre-cut stretch ceiling membrane on-siteAlignment, tensioning, and seamless fitting of membrane onto the installed profilesIntegration of cutouts for lighting, sprinklers, air conditioning vents, speakers, etc.Final finishing, cleaning, and handover of installed ceiling areaRate Includes: Skilled labor, installation tools, on-site execution, and necessary accessories for completing the installation of the stretch ceiling. 140 The Iceil Wooden Box is built from durable MR/BWP-grade plywood, featuring a 12mm back board, 18mm vertical sides (150mm height), and dual 8mm flexible plywood layers for curved designs. The 150mm depth accommodates lighting and structural needs.Finish Options: White emulsion or PU-coated interior, or white reflective laminate; exterior customizable per client.Mounting: Reinforced corners, cross supports (wood/MS) every 2 ft, fixed with dash fasteners, threaded rods, or MS supports.Stretch Ceiling Compatibility: Suits Iceil’s PVC Harpoon Profile System with aluminium profiles for welded membranes.Lighting Integration: Base for rigid block LEDs with ventilation slots for heat dissipation. 141 Wall paper 142 Carpet Flooring 143 160A LT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, Wall mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. The Breakerof 160A TPN MCCB and 1set of 160/5A CT with TNEB Metering provision and 1nos of 160/5A CT for APFCR . (Rate as per Quotation) 144 Supply and Erection of electrical panels Boards 145 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type Three Phase Changer Over panel of size (H 2100 X L 2000 X D 300 ) mm with suitable to accommodate 100A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source, 6nos of 63A 4Pole MCCBs and 4nos of 32A 4Pole MCCBs compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 146 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type 50 kVAR panel of size (H 1800 X L 1800 X D 300 ) mm with suitable to accommodate Incomer 1 Nos 63A 4Pole MCCB, 7nos of 25A 4Pole MCCBs with 7% 1-10 kVAR Capacitor banks in compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 147 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB : Supply and fixingof4way verticalTPMCBsheetsteel Industrial Type TP MCB DB with IP54 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 4 Nos.of32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.( Industrial Type TPMCB DB with IP54 Protections) 148 Supply and fixing of 7 segment8 way63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 63 A TPN MCB, 10kA, / Isolator and another separate 4 way for accommodating one no. 63 Amps, 30 mA, 4 pole ELCB / RCD (totally 8 ways in one segment) and 24 nos 6-32 A, 10kA, SP MCB / Isolators ( totally 24 nos.) for outgoing in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. 149 Supply and fixing of 65 mm dia. (2 -1/2) GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonry pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 90W LED Streetlight fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour 150 Supply and Fixing of24W Ceiling Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 151 Supply and Fixing of11W Bulk Head Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 152 Supply of surface-mounted 24W LED wall lights to the ideal solution for a variety of indoor lighting applications. Direct illumination of the wall and surrounding surface, as well as accent lighting for vertical structures. Featuring an aesthetically pleasing, robust construction, these lights are built to withstand all weather conditions, ensuring long-lasting performance and durability • Luminaire body made of extruded aluminium alloy (grade 6063) with die cast aluminium components and non corrosive SS fasteners • Non yellowing UV stabilized translucent polycarbonate diffuser • Luminaire integrated with 24W LED • Die-cast aluminium mounting base for easy installation onto the wall • Surface mounting on wall using hardware after connecting to the power supply • IP : 65, IK : 08 • Cable entries for through-wiring of mains supply cable • Integral constant current power supply • CRI ( Ra) : >80 • Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply • Available CCT : 2700K, 3000K, 4000K, 5700K. Driver Power Supply : Integral, Input Voltage : 230-240Vac, Frequency : 50-60 Hz, Power Factor : ≥0.95, THD : <10%, Surge Protection : 4KV, Efficiency : >85%, Symmetrical Light Distribution.Product Finish options: Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. CE & BIS Certified. Inhouse NABL accredited lab. Brand Name : Philips, Product SKU : 919215850004 153 Supply of LED Linear Pendant luminaire is a versatile solution for projects that demand high quality of the lighting system and high visual comfort. With its modular design, the Revo-L can be used as an individual fixture or as a combination of luminaires put together in continuous lines • Luminaire made of extruded aluminium for better thermal management • polycarbonate diffuser for optimum optical performance, • Hexa-cell (Matte Black) secondary reflector • Suitable for surface and suspended mounting • Supplied with standard suspension kit (1metre).• Cable entries for through-wiring of mains supply cable • Integral power supply • Suitable for operation on 240V,50Hz single phase ac supply• Driver Power Supply : Integral, Power Factor : >0.90, THD : <10%, Surge Protection : 4KV-6KV, Efficiency : >85%, IP 44 Rating.• Dimension: 1188 x 36 x 75, 2365 x 36 x 75, 3540 x 36 x 75.• Wattage Options : Upto 40W, Upto 80W, Upto 120W.• Mounting: Pendant Mounting, Pendant Mounting, Pendant Mounting, Surface Mounting, Surface Mounting, Surface Mounting • Product Finish options: Pure polyester powder coated, RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 9016 Traffic White • CE & BIS Certified • Inhouse NABL accredited lab. Philips SP170P LED25S-6500 PSU W5L113 OD WH Smartbright Linear 154 Supply of Input power : 8W LED Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire madeof extruded aluminium alloy (grade 6063), die-cast aluminium of high corrosion resistance and non corrosive stainless steel fasteners. Translucent polycarbonate diffuser. Pressure die cast aluminium mounting plate Ø100.5mm x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD55 for surface mounting on floor. The base plate have a cable entry hole of 70 x 24 mm dia at the center. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.9, THD <10%, Surge protection 2.5KV. Luminaire dimension : 106mm diameter x 565mm height. CE & BIS Certified. Foundation Bolt - 2 Nos of M8 Foundation J Bolt Length 150mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each BoltInhouse NABL accredited lab. PHILIPS Bollard BCP100 LED 10W PSU GR L 750mm Solar Light 155 Supply of LED Linear Lighting to suit ceiling / wall is a slim and elegantly designed fixture, suited for varied applications offers a uniform, glareless and soft lighting.Al. Profile Housing Dimension: 1000 x 17 x 8, 2000 x 17 x 8Mounting: Surface Mounting, Product Finish: Anodized Aluminum• Luminaire made of extruded aluminium for better thermal management • PC clear / semi clear matte diffuser for excellent diffused lighting experience throughout the life of the fixture • Designed for mounting on ceiling / wall • Cable entries for through-wiring of mains supply cable • To be used with LED strip & power supply unit of suitable rating. Brand Philips Profile Shine 240 LEDs/m LED Strip | 3000K Warm White | High Brightness Linear Strip for Cove, False Ceiling, Architectural, Ambient Lighting 156 Supply of 24V 2835 Flexible LED Strip, 12W/m, Non-Integral, CCT: 2700K, 4000K, 6500KDimension: 5m / Roll, IP : 67, Brand Name : K-Lite, Code : 7289 or equivalent 157 24V Power supply, IP 67 Rated SMPS suitable for 24V LED Strip lights. Wattage: 150W, 24V Series Waterproof IP67 Power Supply24Vdc 6.25 Amps 150W Power unitDimension: 313 x 43 x 34IP : 67,Brand Name : K-Lite, Code : 8198 or equivalent 158 Supply and fixing of Fans and Air Circulator 159 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star rated complete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 2.5 metre down rod with fan clamp, and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 160 Supply and fixing of 600mm wall mounting Air circulator and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 161 Supply and fixing of 300mm(12)sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessaryaccessories and hardwares as required. 162 Supply and fixing oflouvers shutter arrangements for 300mm(12)sweep (Heavy duty) AC Exhaust fan complete 163 Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required. 164 Supply and Laying of 3 1/2 x 50 sq.mm. PVC Al.Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 165 Supply and Laying of 4C x 16 sq.mm. PVC AL. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.Main Panel to DB 166 Supply and Laying of 3C x 2.5 sq.mm. PVC Cu. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make goodMain Panel / DB to Street Lights 167 Supplying & Laying 120mm/103.5mm HDPE Pipe as per requirements including excavation & refilling. 168 Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection. 169 Supply and fixing of brass cable gland for3 1/2 Cx 50 Sq.mm PVC LTUGAl. Armoured cable with earth connection 170 Supply and fixing of brass cable gland suitable for4C x 16 PVC Al. Armoured LTUG cable with earth connection. 171 Supply and fixing of brass cable gland for 3C x 2.5 sqmm COPPER cableLTUG cablewith earth connection. 172 Supply and providing cable end termination of the following sizePVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable) 173 Supply and providing cable end termination of3 1/2Corex 50Sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. 174 Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete. 175 Supply and providing cable end termination of 3C X 2.5 SqmmPVC LTUGCopper cable with necessary copper cable sockets by crimping etc, with electrical connection complete. 176 Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End (SD-375) 177 Wiring with 2 x 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil)Higher End (SD-385) 178 Supply and fixing of 25A Flushtype Wall Socket 25A DPMCB complete set for ACPlug inflush with wall with earth connection (For AC Plug) 179 Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire and making good of the concealed portion withsuitable colour. ( SD 430 ) 180 Supply and Run of 2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour. 181 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp andwithcopper earth plate of size 125mm x 50mm x 6mm with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonrySD-233 182 Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection 183 Supply and Run of 1 of25.6.25 mm Al. Flat on wall / floor / ground for earth connection. 184 Supply and Run of 1 of25.6.25 mm Cu. Flat on wall / floor / ground for earth connection. 185 Supply, Installation, Testing and commissioning of 40 channel NVR with 4TB HDD * 4nos, Up to 40-ch 8 MP IP cameras can be connected, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by up to 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1/VGA1 outputs provided  HDMI1 Video output ) resolution Storage and Playback, Up to 4SATA interfaces and 1 eSATA interface for HDD connection, Support upto 6TB capacity for each HDD, Smart search for efficient playback.(Make: Hikvision/Dahua/Panasonic) 186 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse.All including suitable camera stand and accessories. (Make: Dahua/Panasonic) 187 Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Each Cameras, 1/2.8 CMOS,4 MP 2592 x1520 or better , triple stream, Min. Illumination required 0.005 Lux/F2.0 (Color,30IRE), 0 Lux/F2.0 (IR ON), 140dB True WDR, triple stream,3 to 12 mm, F1.4 to 2.8 , MFZ, Backlight Compensation, Highlight Compensation 3DNR, Privacy Mask, Internal/External Smart IR LEDs with up to 50m IR distance, H.265& |MJPEG, Inbuilt Video Analytics: Smart Motion Detection, Intrusion Detection, People Counting, Multiloitering, Face Detection, Line Crossing, Missing Object detection, [Unattended Object Detection. THe camera shall have inbuilt cyber security FIPS Chipset.Audio Stream Full Duplex, 1TB SD card support, IP 67 & IK10, Alarm: 1 In & 1out, PoE, H.265 High Profile and MJPEG, PoE Class . Certifications: ONVIF Profile S,G,T & M compliant, NDAA 889 UL, CE, EN, FCC & RoHS compliant and with all accessories and as per detailed tender specifications. 188 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 189 Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 190 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point( Point to Point ) Crimping, Testing and arrangement charges. 191 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 192 Supply and Fixing of Rack with Accessories -Higher end 12 U Rack with LNS unit and fan extra for the above rack. 193 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 194 PA SYSTEMS 195 Supply,installation, testing and commissioning of 30W High efficiency ABS horn loudspeaker with weather protectin IP 65Max Power : 45 W, Rated power, 30 Watts, Power tapping, 30/15/7.5W-Effective frequency range (-10 db) (-380 Hz to 5 kHz) - SPL at rated power (1 khz) 126 dB- Self extinguishing acc. to UL 94 VO - IP 65 acc. to IEC 60529, safety acc. to EN 60065. (Make - BOSCH) 196 Supply, installaion, testing and commissioning of 240W mixer amplifier with following features : inbuilt bluetooth for audio streaming, sports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, insert features to use as a pre/power amplifier, Optional 2 tone chime generation for input 1 technical specifications - Frequency response 80 Hz to 18 kHx (+1/-3 dB W - 10 dB ref. rated output) - Distortion <1% @ rated output power, 1 kHz bass control Max +/- 8 dB Treble control max +/- 8 dB. (Make - BOSCH) 197 Supply, installation, testing and commissioning of Goose Mic 198 Supply and installation ofHandheld microphone with a dynamic transducer element that shall be designed for high speech intelligivility. It should have a rugged enclosure is both stylish and easy to use in a wide range of public and sound reinforcement applications. Polar Pattern unidirectional, frequency range 80 hZ to 12 kHz, Sensitivity 1.7mV/Pa +/- dB, Rate out impedance 600 Ohms. (Make BOSCH) (Market rate) 199 Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., asper standard methods and as directed by the Departmental Officers. 200 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 201 Supply and erection, testing and commissioning of 2.0 TR (6000K.cal/hr) ABS Split type Air conditioner (3 star rating)confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted withhermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZsingle phase AC supply inverter technology with capable of thefollowing performinga) Coolingb) Dehumidifyingc) Air circulatingd) Filteringe) Refrigerant pipe lines – 6 mtr lengthThe installation works for the above split type AC units includethe following1. Mounting / fitting indoor and outdoor units at theirrespective locations2. Laying refrigerant pipe line of required length notexceeding 6 meters distance & connecting both units afterdrilling hole/holes in the wall is required, thickness of the coppertubing shall not be less than 0.7 mm3. Installing the section pipe with expanded polythene foamtubing4. Laying drain pipe to throw out the condensate water beingformed within indoor unit5. Leak testing the entire system unit6. Charging refrigerant gas in the unit7. Suitable electrical wiring with to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoorunit upto 6 meter length and upto switch within 3 meters oflocation of indoor unit. (Like (Carrier / Voltas / Blue Star /Equivalent) as directed by the department officers 202 Supply and fixing of 5 KVA slim and wall mounting (V Guardmake ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 2 TR split ACwith necessary inter connection and earth connection as directedby the departmental officers. 203 LANDSCAPE 204 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 205 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 206 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 207 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 208 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 209 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 210 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
32.
Rural Development #10059405 Price Bid
Provide Provide Electrical Material At V . P . Vadgaon Tal Khalapur Dist Raigad , Supply Elecric Material , Lehar Led 22 Vat , Lehar Led 18 Vat , Syska Led 22 Vat , Syska Led 18 Vat , Philips Led 22 Vat , Philips Led 18 Vat , Syska Led 22 Vat With Sensor , Syska Led 18 Vat With Sensor , Philips Led 22 Vat With Sensor , Philips Led 18 Vat With Sensor , Syska Led Tube 14 Vat With Chock , Philips Led Tube 14 Vat With Chock , Electric Tester ( Taparia Co . ) , Tripple 40 Ampier , Pannel Board With All Fitting , D . P Switch 32 A , Single Phase Pivantar , Polycab 1 . 5 Mm Wire , Polycab 2 . 0 Mm Wire , Cutout Three Phase , Service Wire Aluminium 6 Core , Service Wire Aluminium 8 Core , Service Wire Aluminium 12 Core , Service Cable 3 Phase Coper , Service Cable 4 Phase Coper , Holder For Simple Bulb , Tape Bundle , Tripple 18 Ampier , Tripple 32 Ampier , Starter For 3 Hp Pump ( Lnt Crompton ) , Starter For 5 Hp Pump ( Lnt Crompton ) , Starter For 15 Hp Pump ( Lnt Crompton ) , Street Lite Set Led 50 Wat With All Fitting , Pipe For Cement Poll With Clamp , Nut Bolt , Pipe , Pipe For Iron Poll With Clamp , Nut Bolt , Pipe , Capacitor For Fan , Main Switch Icdp , Simple Bulb 60 Vat Philips , Street Lite Set Led , 50 Wat With All Fitting ( Micronic Co . ) , Street Lite Set Led , 70 Wat With All Fitting ( Micronic Co . ) , Street Lite Set Led , 100 Wat With All Fitting ( Micronic Co . ) , Street Lite Set Led , 50 Wat With All Fitting ( Syska Co . ) , Street Lite Set Led , 70 Wat With All Fitting ( Syska Co . ) , Street Lite Set Led , 100 Wat With All Fitting ( Syska Co . ) , Street Lite Set Led , 50 Wat With All Fitting ( Philips ) , Street Lite Set Led , 70 Wat With All Fitting ( Philips ) , Street Lite Set Led , 100 Wat With All Fitting ( Philips ) , Solar Led Streetlight 50 Wat With All Fitting ( Syska Co . ) , Solar Led Streetlight 70 Wat With All Fitting ( Syska Co . ) , Solar Led Streetlight 100 Wat With All Fitting ( Syska Co . ) , Solar Led Streetlight 50 Wat With All Fitting ( Philips Co . ) , Solar Led Streetlight 70 Wat With All Fitting ( Philips Co . ) , Solar Led Streetlight 100 Wat With All Fitting ( Philips Co . ) , Four Phase Cable Wire , One Phase Fitting Wire , Electric Celling Fan ( Cromton ) , Electric Celling Fan ( Havells ) , Led Bulb Syska 24Wt , Led Bulb Syska 18Wt , Control Panal 32 Amp , Control Panal 63 Amp , Cfl Bulb 75 Vat ( Ajenta ) , Cfl Bulb 75 Vat ( Crompton ) , Screw , Electric Tube 4 Ft Fixtures With All Fitting , Electric Cut Out , Inverter Luminous 1500 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2000 Va ( With All Fitting Including Exide Battery ) , Inverter Luminous 2500 Va ( With All Fitting Including Exide Battery ) , Mccb ( Lt ) 10Amp , Mccb ( Lt ) 16Amp , Mccb ( Lt ) 28Amp , Mccb ( Lt ) 32Amp , Leg 16 , Leg 18 , Leg 32 , Led Booster ( 50 Vat ) ( Micronic Co . ) , Led Booster ( 70 Vat ) ( Micronic Co . ) , Led Booster ( 50 Vat ) ( Syska Co . ) , Led Booster ( 70 Vat ) ( Syska Co . ) , Led Booster ( 50 Vat ) ( Philips Co . ) , Led Booster ( 70 Vat ) ( Philips Co . ) , Led Stips ( 50 Vat ) ( Micronic Co . ) , Led Stips ( 70 Vat ) ( Micronic Co . ) , Led Stips ( 50 Vat ) ( Syska Co . ) , Led Stips ( 70 Vat ) ( Syska Co . ) , Led Stips ( 50 Vat ) ( Philips Co . ) , Led Stips ( 70 Vat ) ( Philips Co . ) , Air Conditioner ( A . C ) 1 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A . C ) 1 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A . C ) 1 . 5 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A . C ) 1 . 5 Ton Carrier ( With Including All Taxes & Service Charges ) , Air Conditioner ( A . C ) 2 Ton Blue Star ( With Including All Taxes & Service Charges ) , Air Conditioner ( A . C ) 2 Ton Carrier ( With Including All Taxes & Service Charges ) , Freeze ( Samsung ) 160 Ltr , Freeze ( Samsung ) 180 Ltr , Freeze ( Lg ) 160 Ltr , Freeze ( Lg ) 180 Ltr , Water Puryfier 12 Ltrs ( With Including Taxes & Services ) , Elctrical Shagadi Prestige 230Vt , Elctrical Shagadi Prestige 2000Wt , Honda Co . Generator ( 7 Kva ) , Honda Co . Generator ( 7 . 5 Kva ) , Honda Co . Generator ( 10 Kva ) , Honda Co . Generator ( 15 Kva ) , Honda Co . Generator ( 20 Kva ) , Runmax Co . Generator 13 Kva ( Silent Soundproof Power Electric Diesel ) , Runmax Co . Generator 15 Kva ( Silent Soundproof Power Electric Diesel ) , Runmax Co . Generator 20 Kva ( Silent Soundproof Power Electric Diesel ) , Electric Safety Hand Gloves , Aluminium Folding Shidi 15 Feet , Aluminium Folding Shidi 20 Feet , Aluminium Folding Ghoda 15 Feet , Aluminium Folding Ghoda 20 Feet , 60 Vatt Led Driver , Led With Pcb , Led Fitting Charges , Smd Led Panel Light 22 Vatt , Fan Hook With Nut Bolt , Led Bulb 18 Vatt ( Philips ) , Led Bulb 24 Vatt ( Philips ) , Switch Board With 3 Switch 2 Plug , Electric Wire , Fan ( Usha Co . ) , Fan ( Orient Co . ) , Three Phase Socket , Button ( Anchor Co . ) , Button ( Havells Co . ) , Three Pin Socket , Three Pin , Two Pin , Dril Machine , Electric Bell ( Havells Co . ) , Electric Bell ( Anchor Co . ) , Led With Sensor ( 22 Vatt ) , Led With Sensor ( 24 Vatt )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
34.
Power #10039728 Price Bid
Entrusting Of Annual Maintenance Contract And Supply Of Spares For Maintenance Of 355 Nos. Of A.C. Units Installed At Legislative Assembly, Chief Secretariat And Main Office, Electricity Department, Puducherry For A Period Of One Year- 1 Entrusting of Annual Maintenance Contract of A.C. Units 2 Legislative Assembly, Puducherry 3 Monthly maintenance charges for Cassette / Vertical type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) 4 Monthly maintenance charges forCassette / Vertical type inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) 5 Monthly maintenance charges for split type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) 6 Monthly maintenance charges for split type inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) 7 Total monthly maintaintence charges for 118 Nos. of A.C. Units 8 Total Annual maintaintence charges for 118 Nos. of A.C. Units 9 Details of spares required for maintenance of Cassette / Vertical type non-inverter A.C. Units 10 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Cassette / Vertical type non-inverter A.C. unit 11 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 12 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 13 Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 14 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 15 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 16 Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 17 Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 18 Replacement of New Rotary compressor Less Buy back value of old compressor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 19 Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 20 Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 21 Provision of new Reciprocating compressor(Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 22 Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) Less buy back value of old Compressor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 23 Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) Less buy back value of old Compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 24 Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Hitachi, LG, Lloyd) Less buy back value of old Compressor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 25 Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 26 Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 27 Replacement of condensing coil Less buy back value of old condensing coil (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 28 Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 29 Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 30 Replacement of evaporating coil Less buy back value of old evaporating coil (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 31 Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 32 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 33 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 34 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 35 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 36 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 37 Fan motor rewinding and fan bush replacement (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 38 Fan motor rewinding and fan bush replacement (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 39 Fan motor rewinding and fan bush replacement (2.5 Ton) forCassette / Vertical type non-inverter A.C. unit 40 Replacement ofindoor Blower (1.5 Ton) for Cassette / Vertical type non-inverter A.C. unit 41 Replacement ofindoor Blower (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 42 Replacement ofindoor Blower (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 43 Replacement of fanoutdoor blade (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 44 Replacement of fanoutdoor blade (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 45 Replacement of fanoutdoor blade (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 46 Replacement of digital remote board (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 47 Replacement of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 48 Replacement of digital remote board (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 49 Repairing of digital remote board (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 50 Repairing of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 51 Repairing of digital remote board (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 52 Replacement of air filter (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 53 Replacement of air filter (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 54 Replacement of air filter (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 55 Replacement of single pole contactor (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 56 Replacement of single pole contactor (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 57 Replacement of single pole contactor (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 58 Replacement of fan capacitor 4-10 mfdfor Cassette / Vertical type non-inverter A.C. Unit 59 Replacement of running capacitor 36 mfdfor Cassette / Vertical type non-inverter A.C. Unit 60 Replacement of running capacitor 45 mfdfor Cassette / Vertical type non-inverter A.C. Unit 61 Replacement of running capacitor 50 mfdfor Cassette / Vertical type non-inverter A.C. Unit 62 Replacement of running capacitor 50+5 mfdfor Cassette / Vertical type non-inverter A.C. Unit 63 Supply and fixing of MCB breaker 20 Amps for Cassette / Vertical type non-inverter A.C. Unit 64 Supply and fixing of MCB breaker 25 Amps for Cassette / Vertical type non-inverter A.C. Unit 65 Supply and fixing of MCB breaker 32 Amps for Cassette / Vertical type non-inverter A.C. Unit 66 Supply and fixing of metal glad plug and socket with MCB for Cassette / Vertical type non-inverter A.C. Unit 67 Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Cassette / Vertical type non-inverter A.C. Unit 68 Shifting of Cassette/Vertical A.C. one location to another location including gas charge (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 69 Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 70 Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 71 Replacement of drain pipe for Cassette / Vertical type non-inverter A.C. Unit 72 Copper pipe with insulation(1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 73 Copper pipe with insulation(2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 74 Copper pipe with insulation (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 75 Thermal insulation with tape for Cassette / Vertical type non-inverter A.C. Unit 76 Complete rewiring kit for Cassette / Vertical type non-inverter A.C. Unit 77 Tinkering charge for outdoor unit for Cassette / Vertical type non-inverter A.C. Unit 78 Stabiliser repairing charge for Cassette / Vertical type non-inverter A.C. Unit 79 Supply of hand remote for Cassette / Vertical type non-inverter A.C. Unit 80 Replacement of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit 81 Repairing of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit 82 Swing Motors for Cassette / Vertical type non-inverter A.C. Unit 83 Dummy valve, ¼, ½, 5/8, 3/8 for Cassette / Vertical type non-inverter A.C. Unit 84 A/C Metal clad plug Top for Cassette / Vertical type non-inverter A.C. Unit 85 A/C Metal clad Socket for Cassette / Vertical type non-inverter A.C. Unit 86 15A modular 3 pin Plug top for Cassette / Vertical type non-inverter A.C. Unit 87 15A modular 3 pin socket for Cassette / Vertical type non-inverter A.C. Unit 88 Room Sensor for Cassette / Vertical type non-inverter A.C. Unit 89 Coil Sensor for Cassette / Vertical type non-inverter A.C. Unit 90 Replacement of outdoor Base plate for Cassette / Vertical type non-inverter A.C. Unit 91 A.C. unit pump down service for Cassette / Vertical type non-inverter A.C. Unit 92 Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit 93 Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit 94 Details of spares required for maintenance of Cassette / Vertical type inverter A.C. Units 95 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 96 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 97 Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 98 Provision of new Reciprocating compressor (Carrier, Blue Star, Haier) (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 99 Replacement of Reciprocating Compressor (Carrier, Blue Star, Haier) Less buy back value of old Compressor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 100 Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 101 Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 102 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 103 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 104 Fan motor rewinding and fan bush replacement (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 105 Replacement ofindoor Blower (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 106 Replacement of fanoutdoor blade (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 107 Replacement of digital remote board (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 108 Repairing of digital remote board (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 109 Replacement of air filter (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 110 Replacement of single pole contactor (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 111 Replacement of indoor main PCB (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 112 Replacement of Indoor sensor PCB (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 113 Replacement of Outdoor PCB (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 114 Replacement of expansion valve (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 115 Replacement of outdoor sensors each (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 116 Supply and fixing of MCB breaker 20 Amps for Cassette / Vertical type inverter A.C. Unit 117 Supply and fixing of MCB breaker 25 Amps for Cassette / Vertical type inverter A.C. Unit 118 Supply and fixing of MCB breaker 32 Amps for Cassette / Vertical type inverter A.C. Unit 119 Supply and fixing of metal glad plug and socket with MCB for Cassette / Vertical type inverter A.C. Unit 120 Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Cassette / Vertical type inverter A.C. Unit 121 Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 122 Replacement of drain pipe for Cassette / Vertical type inverter A.C. Unit 123 Copper pipe with insulation(2.0 Ton) for Cassette / Vertical type inverter A.C. Unit 124 Thermal insulation with tape for Cassette / Vertical type inverter A.C. Unit 125 Complete rewiring kit for Cassette / Vertical type inverter A.C. Unit 126 Tinkering charge for outdoor unit for Cassette / Vertical type inverter A.C. Unit 127 Stabiliser repairing charge for Cassette / Vertical type inverter A.C. Unit 128 Supply of hand remote for Cassette / Vertical type inverter A.C. Unit 129 Replacement of indoor drain pump motor for Cassette / Vertical type inverter A.C. Unit 130 Repairing of indoor drain pump motor for Cassette / Vertical type inverter A.C. Unit 131 Swing Motors for Cassette / Vertical type inverter A.C. Unit 132 Dummy valve, ¼, ½, 5/8, 3/8 for Cassette / Vertical type inverter A.C. Unit 133 A/C Metal clad plug Top for Cassette / Vertical type inverter A.C. Unit 134 A/C Metal clad Socket for Cassette / Vertical type inverter A.C. Unit 135 15A modular 3 pin Plug top for Cassette / Vertical type inverter A.C. Unit 136 15A modular 3 pin socket for Cassette / Vertical type inverter A.C. Unit 137 Room Sensor for Cassette / Vertical type inverter A.C. Unit 138 Coil Sensor for Cassette / Vertical type inverter A.C. Unit 139 Replacement of outdoor Base plate for Cassette / Vertical type inverter A.C. Unit 140 A.C. unit pump down service for Cassette / Vertical type inverter A.C. Unit 141 Details of spares required for maintenance of split type non-inverter A.C. Units 142 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.0 Ton) for Split type non-inverter A.C. Unit 143 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit 144 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit 145 Gas charging (410A Gas) and replacement of capillary tube & strainer (1.0 Ton) for Split type non-inverter A.C. Unit 146 Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit 147 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit 148 Replacement of New Rotary compressor Less Buy back value of old compressor (1.0 Ton) for Split type non-inverter A.C. Unit 149 Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) for Split type non-inverter A.C. Unit 150 Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Split type non-inverter A.C. Unit 151 Provision of new Reciprocating compressor(Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) (1.0 Ton)for Split type non-inverter A.C. Unit 152 Provision of new Reciprocating compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) (1.5 Ton) for Split type non-inverter A.C. Unit 153 Provision of new Reciprocating compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi)for Split type non-inverter A.C. Unit 154 Replacement of Reciprocating Compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) Less buy back value of old Compressor (1.0 Ton) for Split type non-inverter A.C. Unit 155 Replacement of Reciprocating Compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) Less buy back value of old Compressor (1.5 Ton) for Split type non-inverter A.C. Unit 156 Replacement of Reciprocating Compressor (Voltas, Carrier, Blue Star, L.G. Daikin, Hitachi, Vestar, Lloyd, Panasoic, Sharp, Mitsubhishi) Less buy back value of old Compressor (2.0 Ton) for Split type non-inverter A.C. Unit 157 Replacement of condensing coil Less buy back value of old condensing coil (1.0 Ton)for Split type non-inverter A.C. Unit 158 Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton)for Split type non-inverter A.C. Unit 159 Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type non-inverter A.C. Unit 160 Replacement of evaporating coil Less buy back value of old evaporating coil (1.0 Ton)for Split type non-inverter A.C. Unit 161 Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton)for Split type non-inverter A.C. Unit 162 Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type non-inverter A.C. Unit 163 Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.0 Ton)for Split type non-inverter A.C. Unit 164 Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit 165 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type non-inverter A.C. Unit 166 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.0 Ton) for Split type non-inverter A.C. Unit 167 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit 168 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype non-inverter A.C. Unit 169 Fan motor rewinding and fan bush replacement (1.0 Ton)for Split type non-inverter A.C. Unit 170 Fan motor rewinding and fan bush replacement (1.5 Ton)for Split type non-inverter A.C. Unit 171 Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type non-inverter A.C. Unit 172 Replacement ofindoor Blower (1.0 Ton) for Split type non-inverter A.C. Unit 173 Replacement ofindoor Blower (1.5 Ton) for Split type non-inverter A.C. Unit 174 Replacement ofindoor Blower (2.0 Ton) for Split type non-inverter A.C. Unit 175 Replacement of fanoutdoor blade (1.0 Ton)for Split type non-inverter A.C. Unit 176 Replacement of fanoutdoor blade (1.5 Ton)for Split type non-inverter A.C. Unit 177 Replacement of fanoutdoor blade (2.0 Ton)for Split type non-inverter A.C. Unit 178 Replacement of digital remote board (1.0 Ton)for Split type non-inverter A.C. Unit 179 Replacement of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit 180 Replacement of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit 181 Repairing of digital remote board (1.0 Ton)for Split type non-inverter A.C. Unit 182 Repairing of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit 183 Repairing of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit 184 Replacement of air filter (1.0 Ton)for Split type non-inverter A.C. Unit 185 Replacement of air filter (1.5 Ton)for Split type non-inverter A.C. Unit 186 Replacement of air filter (2.0 Ton) for Split type non-inverter A.C. Unit 187 Replacement of single pole contactor (1.0 Ton) for Split type non-inverter A.C. Unit 188 Replacement of single pole contactor (1.5 Ton) for Split type non-inverter A.C. Unit 189 Replacement of single pole contactor (2.0 Ton) for Split type non-inverter A.C. Unit 190 Replacement of fan capacitor 4-10 mfd for Split type non-inverter A.C. Unit 191 Replacement of running capacitor 36 mfd for Split type non-inverter A.C. Unit 192 Replacement of running capacitor 45 mfd for Split type non-inverter A.C. Unit 193 Replacement of running capacitor 50 mfd for Split type non-inverter A.C. Unit 194 Replacement of running capacitor 50+5 mfdfor Splittype non-inverter A.C. Unit 195 Supply and fixing of MCB breaker 20 Amps for Split type non-inverter A.C. Unit 196 Supply and fixing of MCB breaker 25 Amps for Split type non-inverter A.C. Unit 197 Supply and fixing of MCB breaker 32 Amps for Split type non-inverter A.C. Unit 198 Supply and fixing of metal glad plug and socket with MCB for Split type non-inverter A.C. Unit 199 Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type non-inverter A.C. Unit 200 Shifting of Split A.C. one location to another location including gas charge (1.0 Ton) for Split type non-inverter A.C. Unit 201 Shifting of Split A.C. one location to another location including gas charge (1.5 Ton) for Split type non-inverter A.C. Unit 202 Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type non-inverter A.C. Unit 203 Replacement of drain pipe for Split type non-inverter A.C. Unit 204 Copper pipe with insulation(1.0 Ton) for Split type non-inverter A.C. Unit 205 Copper pipe with insulation(1.5 Ton) for Split type non-inverter A.C. Unit 206 Copper pipe with insulation(2.0 Ton) for Split type non-inverter A.C. Unit 207 Thermal insulation with tape for Splittype non-inverter A.C. Unit 208 Complete rewiring kit for Split type non-inverter A.C. Unit 209 Tinkering charge for outdoor unit for Split type non-inverter A.C. Unit 210 Stabiliser repairing charge for Split type non-inverter A.C. Unit 211 Supply of hand remote for Split type non-inverter A.C. Unit 212 Swing Motors for Split type non-inverter A.C. Unit 213 Dummy valve, ¼, ½, 5/8, 3/8for Split type non-inverter A.C. Unit 214 A/C Metal clad plug Top for Split type non-inverter A.C. Unit 215 A/C Metal clad Socket for Split type non-inverter A.C. Unit 216 15A modular 3 pin Plug top for Split type non-inverter A.C. Unit 217 15A modular 3 pin socket for Split type non-inverter A.C. Unit 218 Room Sensor for Split type non-inverter A.C. Unit 219 Coil Sensor for Split type non-inverter A.C. Unit 220 Replacement of outdoor Base plate for Split type non-inverter A.C. Unit 221 A.C. unit pump down service for Split type non-inverter A.C. Unit 222 Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit 223 Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit 224 Details of spares required for maintenance of split type inverter A.C. Units 225 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type inverter A.C. Unit 226 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type inverter A.C. Unit 227 Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type inverter A.C. Unit 228 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type inverter A.C. Unit 229 Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) for Split type inverter A.C. Unit 230 Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Split type inverter A.C. Unit 231 Provision of new Reciprocating compressor (Carrier, Blue Star) (1.5 Ton) for Split type inverter A.C. Unit 232 Provision of new Reciprocating compressor (Carrier, Blue Star) (2.0 Ton) for Split type inverter A.C. Unit 233 Replacement of Reciprocating Compressor (Carrier, Blue Star) Less buy back value of old Compressor (1.5 Ton) for Split type inverter A.C. Unit 234 Replacement of Reciprocating Compressor (Carrier, Blue Star) Less buy back value of old Compressor (2.0 Ton) for Split type inverter A.C. Unit 235 Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton)for Split type inverter A.C. Unit 236 Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type inverter A.C. Unit 237 Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton)for Split type inverter A.C. Unit 238 Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type inverter A.C. Unit 239 Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton)for Split type inverter A.C. Unit 240 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type inverter A.C. Unit 241 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton)for Split type inverter A.C. Unit 242 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype inverter A.C. Unit 243 Fan motor rewinding and fan bush replacement (1.5 Ton)for Split type inverter A.C. Unit 244 Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type inverter A.C. Unit 245 Replacement ofindoor Blower (1.5 Ton) for Split type inverter A.C. Unit 246 Replacement ofindoor Blower (2.0 Ton) for Split type inverter A.C. Unit 247 Replacement of fanoutdoor blade (1.5 Ton)for Split type inverter A.C. Unit 248 Replacement of fanoutdoor blade (2.0 Ton)for Split type inverter A.C. Unit 249 Replacement of digital remote board (1.5 Ton)for Split type inverter A.C. Unit 250 Replacement of digital remote board (2.0 Ton)for Split type inverter A.C. Unit 251 Repairing of digital remote board (1.5 Ton)for Split type inverter A.C. Unit 252 Repairing of digital remote board (2.0 Ton)for Split type inverter A.C. Unit 253 Replacement of air filter (1.5 Ton)for Split type inverter A.C. Unit 254 Replacement of air filter (2.0 Ton) for Split type inverter A.C. Unit 255 Replacement of single pole contactor (1.5 Ton) for Split type inverter A.C. Unit 256 Replacement of single pole contactor (2.0 Ton) for Split type inverter A.C. Unit 257 Replacement of indoor main PCB (1.5 Ton) for splitl type inverter A.C. Unit 258 Replacement of indoor main PCB (2.0 Ton) for splitl type inverter A.C. Unit 259 Replacement of Indoor sensor PCB(1.5 Ton) for splitl type inverter A.C. Unit 260 Replacement of Indoor sensor PCB (2.0 Ton) for splitl type inverter A.C. Unit 261 Replacement of Outdoor PCB(1.5 Ton) for splitl type inverter A.C. Unit 262 Replacement of Outdoor PCB (2.0 Ton) for splitl type inverter A.C. Unit 263 Replacement of expansion valve (1.5 Ton) for splitl type inverter A.C. Unit 264 Replacement of expansion valve (2.0 Ton) for splitl type inverter A.C. Unit 265 Replacement of outdoor sensors each (1.5 Ton) for splitl type inverter A.C. Unit 266 Replacement of outdoor sensors each (2.0 Ton) for splitl type inverter A.C. Unit 267 Supply and fixing of MCB breaker 20 Amps for Split type inverter A.C. Unit 268 Supply and fixing of MCB breaker 25 Amps for Split type inverter A.C. Unit 269 Supply and fixing of MCB breaker 32 Amps for Split type inverter A.C. Unit 270 Supply and fixing of metal glad plug and socket with MCB for Split type inverter A.C. Unit 271 Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type inverter A.C. Unit 272 Shifting of Split A.C. one location to another location including gas charge (1.5 Ton) for Split type inverter A.C. Unit 273 Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type inverter A.C. Unit 274 Replacement of drain pipe for Split type inverter A.C. Unit 275 Copper pipe with insulation(1.5 Ton) for Split type inverter A.C. Unit 276 Copper pipe with insulation(2.0 Ton) for Split type inverter A.C. Unit 277 Thermal insulation with tape for Splittype inverter A.C. Unit 278 Complete rewiring kit for Split type inverter A.C. Unit 279 Tinkering charge for outdoor unit for Split type inverter A.C. Unit 280 Stabiliser repairing charge for Split type inverter A.C. Unit 281 Supply of hand remote for Split type inverter A.C. Unit 282 Swing Motors for Split type inverter A.C. Unit 283 Dummy valve, ¼, ½, 5/8, 3/8for Splittype inverter A.C. Unit 284 A/C Metal clad plug Top for Split type inverter A.C. Unit 285 A/C Metal clad Socket for Split type inverter A.C. Unit 286 15A modular 3 pin Plug top for Split type inverter A.C. Unit 287 15A modular 3 pin socket for Split type inverter A.C. Unit 288 Room Sensor for Split type inverter A.C. Unit 289 Coil Sensor for Split type inverter A.C. Unit 290 Replacement of outdoor Base plate for Split type inverter A.C. Unit 291 A.C. unit pump down service for Split type inverter A.C. Unit 292 Chief Secretariat, Puducherry 293 Monthly maintenance charges for Cassette / Vertical type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) 294 Monthly maintenance charges for split type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) 295 Total monthly maintaintence charges for 142 Nos. of A.C. Units 296 Total Annual maintaintence charges for 142 Nos. of A.C. Units 297 Details of spares required for maintenance of Cassette / Vertical type non-inverter A.C. Units 298 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Cassette / Vertical type non-inverter A.C. unit 299 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 300 Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 301 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 302 Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 303 Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 304 Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Lloyd) (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 305 Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Lloyd) (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 306 Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Lloyd) Less buy back value of old Compressor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 307 Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Lloyd) Less buy back value of old Compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 308 Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 309 Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 310 Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 311 Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 312 Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 313 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 314 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 315 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 316 Fan motor rewinding and fan bush replacement (1.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 317 Fan motor rewinding and fan bush replacement (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 318 Replacement ofindoor Blower (1.5 Ton) for Cassette / Vertical type non-inverter A.C. unit 319 Replacement ofindoor Blower (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 320 Replacement of fanoutdoor blade (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 321 Replacement of fanoutdoor blade (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 322 Replacement of digital remote board (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 323 Replacement of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 324 Repairing of digital remote board (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 325 Repairing of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 326 Replacement of air filter (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 327 Replacement of air filter (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 328 Replacement of single pole contactor (1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 329 Replacement of single pole contactor (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 330 Replacement of fan capacitor 4-10 mfdfor Cassette / Vertical type non-inverter A.C. Unit 331 Replacement of running capacitor 36 mfdfor Cassette / Vertical type non-inverter A.C. Unit 332 Replacement of running capacitor 45 mfdfor Cassette / Vertical type non-inverter A.C. Unit 333 Replacement of running capacitor 50 mfdfor Cassette / Vertical type non-inverter A.C. Unit 334 Replacement of running capacitor 50+5 mfdfor Cassette / Vertical type non-inverter A.C. Unit 335 Supply and fixing of MCB breaker 20 Amps for Cassette / Vertical type non-inverter A.C. Unit 336 Supply and fixing of MCB breaker 25 Amps for Cassette / Vertical type non-inverter A.C. Unit 337 Supply and fixing of MCB breaker 32 Amps for Cassette / Vertical type non-inverter A.C. Unit 338 Supply and fixing of metal glad plug and socket with MCB for Cassette / Vertical type non-inverter A.C. Unit 339 Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Cassette / Vertical type non-inverter A.C. Unit 340 Shifting of Cassette/Vertical A.C. one location to another location including gas charge(1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 341 Shifting of Cassette/Vertical A.C. one location to another location including gas charge(2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 342 Replacement of drain pipe for Cassette / Vertical type non-inverter A.C. Unit 343 Copper pipe with insulation(1.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 344 Copper pipe with insulation(2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 345 Thermal insulation with tape for Cassette / Vertical type non-inverter A.C. Unit 346 Complete rewiring kit for Cassette / Vertical type non-inverter A.C. Unit 347 Tinkering charge for outdoor unit for Cassette / Vertical type non-inverter A.C. Unit 348 Stabiliser repairing charge for Cassette / Vertical type non-inverter A.C. Unit 349 Supply of hand remote for Cassette / Vertical type non-inverter A.C. Unit 350 Replacement of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit 351 Repairing of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit 352 Swing Motors for Cassette / Vertical type non-inverter A.C. Unit 353 Dummy valve, ¼, ½, 5/8, 3/8 for Cassette / Vertical type non-inverter A.C. Unit 354 A/C Metal clad plug Top for Cassette / Vertical type non-inverter A.C. Unit 355 A/C Metal clad Socket for Cassette / Vertical type non-inverter A.C. Unit 356 15A modular 3 pin Plug top for Cassette / Vertical type non-inverter A.C. Unit 357 15A modular 3 pin socket for Cassette / Vertical type non-inverter A.C. Unit 358 Room Sensor for Cassette / Vertical type non-inverter A.C. Unit 359 Coil Sensor for Cassette / Vertical type non-inverter A.C. Unit 360 Replacement of outdoor Base plate for Cassette / Vertical type non-inverter A.C. Unit 361 A.C. unit pump down service for Cassette / Vertical type non-inverter A.C. Unit 362 Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit 363 Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit 364 Details of spares required for maintenance of split type non-inverter A.C. Units 365 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit 366 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit 367 Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit 368 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit 369 Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) for Split type non-inverter A.C. Unit 370 Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Split type non-inverter A.C. Unit 371 Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Panasonic, Mitshubhishi, Hitachi, Llyod, Haier, Voltas) (1.5 Ton) for Split type non-inverter A.C. Unit 372 Provision of new Reciprocating compressor (Carrier, Blue Star, Daikin, Panasonic, Mitshubhishi, Hitachi, Llyod, Haier, Voltas) (2.0 Ton) for Split type non-inverter A.C. Unit 373 Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Panasonic, Mitshubhishi, Hitachi, Llyod, Haier, Voltas) Less buy back value of old Compressor (1.5 Ton) for Split type non-inverter A.C. Unit 374 Replacement of Reciprocating Compressor (Carrier, Blue Star, Daikin, Panasonic, Mitshubhishi, Hitachi, Llyod, Haier, Voltas) Less buy back value of old Compressor (2.0 Ton) for Split type non-inverter A.C. Unit 375 Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton)for Split type non-inverter A.C. Unit 376 Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type non-inverter A.C. Unit 377 Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton)for Split type non-inverter A.C. Unit 378 Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type non-inverter A.C. Unit 379 Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit 380 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type non-inverter A.C. Unit 381 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit 382 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype non-inverter A.C. Unit 383 Fan motor rewinding and fan bush replacement (1.5 Ton)for Split type non-inverter A.C. Unit 384 Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type non-inverter A.C. Unit 385 Replacement ofindoor Blower (1.5 Ton) for Split type non-inverter A.C. Unit 386 Replacement ofindoor Blower (2.0 Ton) for Split type non-inverter A.C. Unit 387 Replacement of fanoutdoor blade (1.5 Ton)for Split type non-inverter A.C. Unit 388 Replacement of fanoutdoor blade (2.0 Ton)for Split type non-inverter A.C. Unit 389 Replacement of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit 390 Replacement of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit 391 Repairing of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit 392 Repairing of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit 393 Replacement of air filter (1.5 Ton)for Split type non-inverter A.C. Unit 394 Replacement of air filter (2.0 Ton) for Split type non-inverter A.C. Unit 395 Replacement of single pole contactor (1.5 Ton) for Split type non-inverter A.C. Unit 396 Replacement of single pole contactor (2.0 Ton) for Split type non-inverter A.C. Unit 397 Replacement of fan capacitor 4-10 mfd for Split type non-inverter A.C. Unit 398 Replacement of running capacitor 36 mfd for Split type non-inverter A.C. Unit 399 Replacement of running capacitor 45 mfd for Split type non-inverter A.C. Unit 400 Replacement of running capacitor 50 mfd for Split type non-inverter A.C. Unit 401 Replacement of running capacitor 50+5 mfdfor Splittype non-inverter A.C. Unit 402 Supply and fixing of MCB breaker 20 Amps for Split type non-inverter A.C. Unit 403 Supply and fixing of MCB breaker 25 Amps for Split type non-inverter A.C. Unit 404 Supply and fixing of MCB breaker 32 Amps for Split type non-inverter A.C. Unit 405 Supply and fixing of metal glad plug and socket with MCB for Split type non-inverter A.C. Unit 406 Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type non-inverter A.C. Unit 407 Shifting of Split A.C. one location to another location including gas charge (1.5 Ton) for Split type non-inverter A.C. Unit 408 Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type non-inverter A.C. Unit 409 Replacement of drain pipe for Split type non-inverter A.C. Unit 410 Copper pipe with insulation(1.5 Ton) for Split type non-inverter A.C. Unit 411 Copper pipe with insulation(2.0 Ton) for Split type non-inverter A.C. Unit 412 Thermal insulation with tape for Splittype non-inverter A.C. Unit 413 Complete rewiring kit for Split type non-inverter A.C. Unit 414 Tinkering charge for outdoor unit for Split type non-inverter A.C. Unit 415 Stabiliser repairing charge for Split type non-inverter A.C. Unit 416 Supply of hand remote for Split type non-inverter A.C. Unit 417 Swing Motors for Split type non-inverter A.C. Unit 418 Dummy valve, ¼, ½, 5/8, 3/8for Split type non-inverter A.C. Unit 419 A/C Metal clad plug Top for Split type non-inverter A.C. Unit 420 A/C Metal clad Socket for Split type non-inverter A.C. Unit 421 15A modular 3 pin Plug top for Split type non-inverter A.C. Unit 422 15A modular 3 pin socket for Split type non-inverter A.C. Unit 423 Room Sensor for Split type non-inverter A.C. Unit 424 Coil Sensor for Split type non-inverter A.C. Unit 425 Replacement of outdoor Base plate for Split type non-inverter A.C. Unit 426 A.C. unit pump down service for Split type non-inverter A.C. Unit 427 Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit 428 Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit 429 Main office, Electricity Department, Puducherry 430 Monthly maintenance charges for Cassette / Vertical type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) 431 Monthly maintenance charges for split type non-inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) 432 Monthly maintenance charges for split type inverter A.C. units (including cleaning of filter, indoor & outdoor units, checking of electrical accessories and cooling efficiency) 433 Total monthly maintaintence charges for 95 Nos. of A.C. Units 434 Total Annual maintaintence charges for 95 Nos. of A.C. Units 435 Details of spares required for maintenance of Cassette / Vertical type non-inverter A.C. Units 436 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 437 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 438 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 439 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 440 Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 441 Replacement of New Rotary compressor Less Buy back value of old compressor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 442 Provision of new Reciprocating compressor (Blue Star, Daikin, Carrier) (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 443 Provision of new Reciprocating compressor (Blue Star, Daikin, Carrier) (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 444 Replacement of Reciprocating Compressor (Blue Star, Daikin, Carrier)Less buy back value of old Compressor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 445 Replacement of Reciprocating Compressor (Blue Star, Daikin, Carrier)Less buy back value of old Compressor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 446 Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 447 Replacement of condensing coil Less buy back value of old condensing coil (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 448 Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 449 Replacement of evaporating coil Less buy back value of old evaporating coil (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 450 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 451 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 452 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 453 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.5 Ton) forCassette / Vertical type non-inverter A.C. Unit 454 Fan motor rewinding and fan bush replacement (2.0 Ton) forCassette / Vertical type non-inverter A.C. Unit 455 Fan motor rewinding and fan bush replacement (2.5 Ton) forCassette / Vertical type non-inverter A.C. unit 456 Replacement ofindoor Blower (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 457 Replacement ofindoor Blower (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 458 Replacement of fanoutdoor blade (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 459 Replacement of fanoutdoor blade (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 460 Replacement of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 461 Replacement of digital remote board (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 462 Repairing of digital remote board (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 463 Repairing of digital remote board (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 464 Replacement of air filter (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 465 Replacement of air filter (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 466 Replacement of single pole contactor (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 467 Replacement of single pole contactor (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 468 Replacement of fan capacitor 4-10 mfdfor Cassette / Vertical type non-inverter A.C. Unit 469 Replacement of running capacitor 36 mfdfor Cassette / Vertical type non-inverter A.C. Unit 470 Replacement of running capacitor 45 mfdfor Cassette / Vertical type non-inverter A.C. Unit 471 Replacement of running capacitor 50 mfdfor Cassette / Vertical type non-inverter A.C. Unit 472 Replacement of running capacitor 50+5 mfdfor Cassette / Vertical type non-inverter A.C. Unit 473 Supply and fixing of MCB breaker 20 Amps for Cassette / Vertical type non-inverter A.C. Unit 474 Supply and fixing of MCB breaker 25 Amps for Cassette / Vertical type non-inverter A.C. Unit 475 Supply and fixing of MCB breaker 32 Amps for Cassette / Vertical type non-inverter A.C. Unit 476 Supply and fixing of metal glad plug and socket with MCB for Cassette / Vertical type non-inverter A.C. Unit 477 Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Cassette / Vertical type non-inverter A.C. Unit 478 Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 479 Shifting of Cassette/Vertical A.C. one location to another location including gas charge (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 480 Replacement of drain pipe for Cassette / Vertical type non-inverter A.C. Unit 481 Copper pipe with insulation(2.0 Ton) for Cassette / Vertical type non-inverter A.C. Unit 482 Copper pipe with insulation (2.5 Ton) for Cassette / Vertical type non-inverter A.C. Unit 483 Thermal insulation with tape for Cassette / Vertical type non-inverter A.C. Unit 484 Complete rewiring kit for Cassette / Vertical type non-inverter A.C. Unit 485 Tinkering charge for outdoor unit for Cassette / Vertical type non-inverter A.C. Unit 486 Stabiliser repairing charge for Cassette / Vertical type non-inverter A.C. Unit 487 Supply of hand remote for Cassette / Vertical type non-inverter A.C. Unit 488 Replacement of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit 489 Repairing of indoor drain pump motor for Cassette / Vertical type non-inverter A.C. Unit 490 Swing Motors for Cassette / Vertical type non-inverter A.C. Unit 491 Dummy valve, ¼, ½, 5/8, 3/8 for Cassette / Vertical type non-inverter A.C. Unit 492 A/C Metal clad plug Top for Cassette / Vertical type non-inverter A.C. Unit 493 A/C Metal clad Socket for Cassette / Vertical type non-inverter A.C. Unit 494 15A modular 3 pin Plug top for Cassette / Vertical type non-inverter A.C. Unit 495 15A modular 3 pin socket for Cassette / Vertical type non-inverter A.C. Unit 496 Room Sensor for Cassette / Vertical type non-inverter A.C. Unit 497 Coil Sensor for Cassette / Vertical type non-inverter A.C. Unit 498 Replacement of outdoor Base plate for Cassette / Vertical type non-inverter A.C. Unit 499 A.C. unit pump down service for Cassette / Vertical type non-inverter A.C. Unit 500 Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit 501 Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Cassette / Vertical type non-inverter A.C. Unit 502 Details of spares required for maintenance of split type non-inverter A.C. Units 503 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit 504 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit 505 Gas charging (410A Gas) and replacement of capillary tube & strainer (1.5 Ton) for Split type non-inverter A.C. Unit 506 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type non-inverter A.C. Unit 507 Replacement of New Rotary compressor Less Buy back value of old compressor (1.5 Ton) for Split type non-inverter A.C. Unit 508 Replacement of New Rotary compressor Less Buy back value of old compressor (2.0 Ton) for Split type non-inverter A.C. Unit 509 Provision of new Reciprocating compressor (Carrier, Blue Star, L.G. Daikin, Haier, Llyod, Panasonic, Mitshubhishi) (1.5 Ton) for Split type non-inverter A.C. Unit 510 Provision of new Reciprocating compressor (Carrier, Blue Star, L.G. Daikin, Haier, Llyod, Panasonic, Mitshubhishi)(2.0 Ton) for Split type non-inverter A.C. Unit 511 Replacement of Reciprocating Compressor (Carrier, Blue Star, L.G. Daikin, Haier, Llyod, Panasonic, Mitshubhishi) Less buy back value of old Compressor (1.5 Ton) for Split type non-inverter A.C. Unit 512 Replacement of Reciprocating Compressor (Carrier, Blue Star, L.G. Daikin, Haier, Llyod, Panasonic, Mitshubhishi) Less buy back value of old Compressor (2.0 Ton) for Split type non-inverter A.C. Unit 513 Replacement of condensing coil Less buy back value of old condensing coil (1.5 Ton)for Split type non-inverter A.C. Unit 514 Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type non-inverter A.C. Unit 515 Replacement of evaporating coil Less buy back value of old evaporating coil (1.5 Ton)for Split type non-inverter A.C. Unit 516 Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type non-inverter A.C. Unit 517 Replacement of indoor fan motor Less buy back value of old indoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit 518 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type non-inverter A.C. Unit 519 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (1.5 Ton)for Split type non-inverter A.C. Unit 520 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype non-inverter A.C. Unit 521 Fan motor rewinding and fan bush replacement (1.5 Ton)for Split type non-inverter A.C. Unit 522 Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type non-inverter A.C. Unit 523 Replacement ofindoor Blower (1.5 Ton) for Split type non-inverter A.C. Unit 524 Replacement ofindoor Blower (2.0 Ton) for Split type non-inverter A.C. Unit 525 Replacement of fanoutdoor blade (1.5 Ton)for Split type non-inverter A.C. Unit 526 Replacement of fanoutdoor blade (2.0 Ton)for Split type non-inverter A.C. Unit 527 Replacement of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit 528 Replacement of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit 529 Repairing of digital remote board (1.5 Ton)for Split type non-inverter A.C. Unit 530 Repairing of digital remote board (2.0 Ton)for Split type non-inverter A.C. Unit 531 Replacement of air filter (1.5 Ton)for Split type non-inverter A.C. Unit 532 Replacement of air filter (2.0 Ton) for Split type non-inverter A.C. Unit 533 Replacement of single pole contactor (1.5 Ton) for Split type non-inverter A.C. Unit 534 Replacement of single pole contactor (2.0 Ton) for Split type non-inverter A.C. Unit 535 Replacement of fan capacitor 4-10 mfd for Split type non-inverter A.C. Unit 536 Replacement of running capacitor 36 mfd for Split type non-inverter A.C. Unit 537 Replacement of running capacitor 45 mfd for Split type non-inverter A.C. Unit 538 Replacement of running capacitor 50 mfd for Split type non-inverter A.C. Unit 539 Replacement of running capacitor 50+5 mfdfor Splittype non-inverter A.C. Unit 540 Supply and fixing of MCB breaker 20 Amps for Split type non-inverter A.C. Unit 541 Supply and fixing of MCB breaker 25 Amps for Split type non-inverter A.C. Unit 542 Supply and fixing of MCB breaker 32 Amps for Split type non-inverter A.C. Unit 543 Supply and fixing of metal glad plug and socket with MCB for Split type non-inverter A.C. Unit 544 Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type non-inverter A.C. Unit 545 Shifting of Split A.C. one location to another location including gas charge (1.5 Ton) for Split type non-inverter A.C. Unit 546 Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type non-inverter A.C. Unit 547 Replacement of drain pipe for Split type non-inverter A.C. Unit 548 Copper pipe with insulation(1.5 Ton) for Split type non-inverter A.C. Unit 549 Copper pipe with insulation(2.0 Ton) for Split type non-inverter A.C. Unit 550 Thermal insulation with tape for Splittype non-inverter A.C. Unit 551 Complete rewiring kit for Split type non-inverter A.C. Unit 552 Tinkering charge for outdoor unit for Split type non-inverter A.C. Unit 553 Stabiliser repairing charge for Split type non-inverter A.C. Unit 554 Supply of hand remote for Split type non-inverter A.C. Unit 555 Swing Motors for Split type non-inverter A.C. Unit 556 Dummy valve, ¼, ½, 5/8, 3/8for Split type non-inverter A.C. Unit 557 A/C Metal clad plug Top for Split type non-inverter A.C. Unit 558 A/C Metal clad Socket for Split type non-inverter A.C. Unit 559 15A modular 3 pin Plug top for Split type non-inverter A.C. Unit 560 15A modular 3 pin socket for Split type non-inverter A.C. Unit 561 Room Sensor for Split type non-inverter A.C. Unit 562 Coil Sensor for Split type non-inverter A.C. Unit 563 Replacement of outdoor Base plate for Split type non-inverter A.C. Unit 564 A.C. unit pump down service for Split type non-inverter A.C. Unit 565 Replacement of 4 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit 566 Replacement of 5 KVA Wall mounting Stablizer Less buy back value of old stablizer for Split type non-inverter A.C. Unit 567 Details of spares required for maintenance of split type inverter A.C. Units 568 Gas charging (R-22/32 Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type inverter A.C. Unit 569 Gas charging (410A Gas) and replacement of capillary tube & strainer (2.0 Ton) for Split type inverter A.C. Unit 570 Replacement of New Rotary compressor (Carrier) Less Buy back value of old compressor (2.0 Ton) for Split type inverter A.C. Unit 571 Provision of new Reciprocating compressor (Carrier) (2.0 Ton) for Split type inverter A.C. Unit 572 Replacement of Reciprocating Compressor(Carrier) Less buy back value of old Compressor (2.0 Ton) for Split type inverter A.C. Unit 573 Replacement of condensing coil Less buy back value of old condensing coil (2.0 Ton)for Split type inverter A.C. Unit 574 Replacement of evaporating coil Less buy back value of old evaporating coil (2.0 Ton)for Split type inverter A.C. Unit 575 Replacement of indoor fan motor Less buy back value of old indoor fan motor (2.0 Ton)for Split type inverter A.C. Unit 576 Replacement of outdoor fan motor Less buy back value of old outdoor fan motor (2.0 Ton) for Splittype inverter A.C. Unit 577 Fan motor rewinding and fan bush replacement (2.0 Ton)for Split type inverter A.C. Unit 578 Replacement ofindoor Blower (2.0 Ton) for Split type inverter A.C. Unit 579 Replacement of fanoutdoor blade (2.0 Ton)for Split type inverter A.C. Unit 580 Replacement of digital remote board (2.0 Ton)for Split type inverter A.C. Unit 581 Repairing of digital remote board (2.0 Ton)for Split type inverter A.C. Unit 582 Replacement of air filter (2.0 Ton) for Split type inverter A.C. Unit 583 Replacement of single pole contactor (2.0 Ton) for Split type inverter A.C. Unit 584 Replacement of indoor main PCB (2.0 Ton) for splitl type inverter A.C. Unit 585 Replacement of Indoor sensor PCB (2.0 Ton) for splitl type inverter A.C. Unit 586 Replacement of Outdoor PCB (2.0 Ton) for splitl type inverter A.C. Unit 587 Replacement of expansion valve (2.0 Ton) for splitl type inverter A.C. Unit 588 Replacement of outdoor sensors each (2.0 Ton) for splitl type inverter A.C. Unit 589 Supply and fixing of MCB breaker 20 Amps for Split type inverter A.C. Unit 590 Supply and fixing of MCB breaker 25 Amps for Split type inverter A.C. Unit 591 Supply and fixing of MCB breaker 32 Amps for Split type inverter A.C. Unit 592 Supply and fixing of metal glad plug and socket with MCB for Split type inverter A.C. Unit 593 Supply and laying of standard size 3 core, 2.5 Sqmm multistrand copper flexible cord wire for Split type inverter A.C. Unit 594 Shifting of Split A.C. one location to another location including gas charge (2.0 Ton) for Split type inverter A.C. Unit 595 Replacement of drain pipe for Split type inverter A.C. Unit 596 Copper pipe with insulation(2.0 Ton) for Split type inverter A.C. Unit 597 Thermal insulation with tape for Splittype inverter A.C. Unit 598 Complete rewiring kit for Split type inverter A.C. Unit 599 Tinkering charge for outdoor unit for Split type inverter A.C. Unit 600 Stabiliser repairing charge for Split type inverter A.C. Unit 601 Supply of hand remote for Split type inverter A.C. Unit 602 Swing Motors for Split type inverter A.C. Unit 603 Dummy valve, ¼, ½, 5/8, 3/8for Splittype inverter A.C. Unit 604 A/C Metal clad plug Top for Split type inverter A.C. Unit 605 A/C Metal clad Socket for Split type inverter A.C. Unit 606 15A modular 3 pin Plug top for Split type inverter A.C. Unit 607 15A modular 3 pin socket for Split type inverter A.C. Unit 608 Room Sensor for Split type inverter A.C. Unit 609 Coil Sensor for Split type inverter A.C. Unit 610 Replacement of outdoor Base plate for Split type inverter A.C. Unit 611 A.C. unit pump down service for Split type inverter A.C. Unit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
35.
Railways #9986213 AOC
Bids Are invited for 1 Supply of BaƩery 12 V 42 AH SMF VRLA BaƩeries perform characterisƟc confirming to JISC 8702/1998 with interconnectors and fasteners complete set along with 2 year warranty confirming to Model Exide SMF 12 v 42 AH baƩery from Exide or Amaron or Luminous or Okaya. 2 SMF VRL 12 Volt BaƩery of 26AH for UPS Make- Amaron Quanta /EXIDE/Luminous/OKAYA/ 3 SUPPLY , INSTALLATION AND COMMISSIONING OF WALL MOUNTED INVERTER TYPE 1.5 TON CAPACITY FIVE STAR RATED COOLING MACHINE ( VARIABAL SPEED ) COMPRESSOR TYPE - BLDC RATED ISEER VALUE 5 AND ABOVE INPUT POWER SUPPLY 230 V AC (+/- 0 % ) 50 HZ WITH ONE SET HEAVY DUTY MS STAND SUITABLE FOR OUTDOOR UNIT AND ADDITIONAL MATERIAL REQUIRED ( EXCEPT STANDARD INSTALLATION MATERIAL) 10 FEET COPPER PIPE, INSULATION, 2.5 SQMM FRLS COPPER FLEXIBLE INSULATED CABLE. NOTE : (1) REQUIRE MINIMUM 10 YRS WARRENTY ON COMPRESSOR AND 5 YRS WARRENTY ON ALL TYPE OF PCB CIRCUITS AND REST PART OF MACHINE. (2) MAKE : LLOYAD, DAIKIN, VOLTAS, CARRIER, SAMSUNG, LG, BLUE STAR, HAIER, IFB, HITACHI (3) SUPPLY , INSTALLATION AND COMMISSIONING AT NAVLAKHI STATION (4) OEM/AUTHORIZED DEALER PROOF OF PURCHASE, WARRENTY CERTIFICATE AND TEST REPORT TO BE SUBMITTED ALONG WITH THE MATERIAL SUPLLIED.(5)AddiƟonal wire and copper pipe will be supplied as per site requirement. 4 Supply of 45mm X 25mm PVC channel with closure of Premium Make: Ply tray, Maruthi or Superior Only 5 Rectangular stackable mild steel storage bins with flap type opening at top and locking arrangement. SpecificaƟon aƩached in Annexure Total Quantity : 467
Contract Date: Ref. Documents Contract Value : 6.98 Lakh
Government Departments No of Bidders 3
37.
Railways #9926792 AOC
Supply Of Track Machine Spares Of Plasser Maketrack Machine Spares Of Plasser Make,Press. Limiting Valve As Per Plasser Part No. Hy511.54. Make: Plasser ] , Cylinder As Per Plasser Part No:Hzpa.050.036.0800.1.001 + Yoke Hz 60.01.2 Make: Plasse R ] , Filter Element As Per Plasser Part No: Hy-S501.160.P10/Es, Make- Plasser Ind. ] , Filter As Per Plasser Part No. 62.05.1000.470. Make: Plasser ] , Shim As Per Plasser Part No:90X75x1,6B1ms Make:Plasser. ] , Seal Kit As Per Plasser Part No. Hy56r/Ds, Make- Plasser Imp ] , Printed Circuit Board Cpl As Per Plasser Part No. :Ek-2186Lv-00A , Make - Plasser Imp ] , Printed Circuit Board Cpl As Per Plasser Part No. Ek-727A-00 Make: Plasser Imp ] , Power Supply As Per Plasser Part No. Ek-819Sv-00(02) Make:Plasser Imp. ] , Pcb Not Programmed As Per Plasser Part No: Elb-Ep0-00A-Mbi, Make: Plasser Imp ] , Micro Controller For Squeezing As Per Plasser Part No. Elb-Em0-03-08/298F Substit Ute Part No. Ek-637Mc-00D/187F, Make - Plasser. ] , Printed Circuit Board Cpl As Per Plasser Part No. Elb-Sm0-00, Make - Plasser ] , Datamatic Module As Per Plasser Part No. Elb-M00-02-003-Mcl113, Make - Plasser. ] , Printed Circuit Board As Per Plasser Part No. Elb-M00-01-001 Mcl164 Make - Plasser ] , Digital Display As Per Plasser Part No.El-T5586.00, Make-Plasser ] , Colour Camera Famos 40 Pal As Per Plasser Part No. 171050,Make:Plasser Imp ] , Relay 500A As Per Plasser Part No. El-T700-00018, Make-Plasser Imp ] , Pressure Switch As Per Plasser Part No:64.07.1000.55 Make:Plasser Imp ] , Proportional Transducer-Dts As Per Plasser Part No.El-T1064.00, Make-Plasser Imp ] , Revolution Counter As Per Plasser Part No:El-T1264.00W/B And Sub Part No. El-T1264.0 0W/A, Make:Plasser Imp ] , Indicator As Per Plasser Part No:El-T1585/20V Make: Plasser Imp ] , Amperemeter As Per Plasser Part No:El-T7013.00A/Ersatz Or El-T 7013.00B Make:Plass Er Imp ] , Distance Measuring Wheel Complete As Per Plasser Part No: El-T2105.00 Make:Plasse R Imp ] , Indicator As Per Plasser Part No:El-T7089.00/50 Make: Plasser Imp ] , Wheel As Per Plasser Part No. El-T2105.03, Make - Plasser Imp ] , Transducer As Per Plasser Part No:El-T2002.00/700 Make:Plasser Imp ] , Auto Centering Transducer As Per Plasser Part No. Elt-906-00001-U/1000. Make: Plass Er ] , Rope Transducer As Per Plasser Part No. El-T906-00001-I/800, Make- Plasser Imp ] , Transducer As Per Plasser Part No.El-T902-00004-U, Make-Plasser Imp ] , Angle Sensor (Proportional Transducer ) As Per Plasser Part No.El-T905-00006-U/50 , Make-Plasser Imp ] , Absolute Distance Value Sensor As Per Plasser Part No. Elt-200-00001A, Make-Plass Er Imp ] , Socket 4Poles As Per Plasser Part No.Erb.2E.304.Cll Or Rae2304p, Make-Plasser ] , Display Unit As Per Plasser Part No Elb-Sm0-01-Uu4, Make-Plasser. ] , Display Unit As Per Plasser Part No. Elb-Sm0-01, Make- Plasser Imp ] , Display Unit As Per Plasser Part No. Elb-Sm0-01-Uu2, Make - Plasser ] , Carrier As Per Plasser Part No:64.04.3257 . Make: Plasser. ] , Shaft As Per Plasser Part No. Ud64.802. Make-Plasser. ] Page 3 Of 11 Run Date/Time: 27/11/2025 17:18:21Stores/South Central Rly Tender Document , Spring As Per Plasser Part No:Wn131-35-223.335-1-Db Make: Plasser. ] , Seal Ring As Per Plasser Part No:2-05776 & Sub 2-22155 Make: Plasser. ] , Seal Ring As Per Plasser Part No:2-24570. Make: Plasser. ] , Nave Unit , As Per Plasser Plasser Part No: A3-20898 Make:Plasser ] , Carrier, As Per Plasser Part No.Wn 152.5480.16/32-4, Make: Plasser. ] , Flange As Per Plasser Part No:63.09.2076 Make: Plasser. ] , Bush , As Per Plasser Part No:64.02.2107.00 Make:Plasser ] , Cutter Bar As Per Plasser Part No. Rm.08B.25.2150.01.Pind.Sp1676, Make : Plasser ] , Toothed Gear , As Per Plasser Part No:Wn70.402E Make:Plasser ] , Slide Plate , As Per Plasser Part No:Ud61.402-Pas Make:Plasser ] , Sweeper Element As Per Plasser Part No: 33X55x320mm-Lg & Sub. No.62.10.4076 Make :Plasser. ] , Bearing , As Per Plasser Part No:5118002.11Mn70 Make:Plasser ]
Contract Date: Apr 02, 2026 Contract Value : 3.44 Crore
Government Departments No of Bidders 1
Andhra Pradesh View Result →
38.
Public Administrative Department #9920679 AOC
Tender For Supply Of Street Light Materials , Street Light Materials , 40 W Tube Light , 40 W Tube Light Starter , 40 W Copper Choke , 40 W Electronic Choke , Tube Light Side Holder , 40W Tubular Fluoresent Super Brigth Lamp , 40W Ballast For Fluoresent Lamp , 40W Planet Electronic Ballase Heavy Duty , 1 X 40 W Street Light Fitting Cover (Cylinder) , 1 X 40 W Street Light Fitting Cover (Square) , 1 X 40 W Street Light Fitting , 1 X 40 W Street Light Fitting Pipe , 1 X 40 W Street Light Fitting Clamp , 1 X 40 W Street Light Fitting Side Holder , 20W Led Street Light Fitting Set , 25W Led Street Light Fitting Set , 30W Led Street Light Fitting Set , 36W Led Street Light Fitting Set , 45W Led Street Light Fitting Set , 50W Led Street Light Fitting Set , 60W Led Street Light Fitting Set , 100W Led Street Light Fitting Set , 150W Led Street Light Fitting Set , 1/18 Pvc Insulated Copper Wire , 3/20 (2.0 Sqmm) Flex Copper Wire , 3/20 Pvc Insulated Vir Copper Wire , 7/16 Pvc Insulated Vir Copper Wire , 7/20 Pvc Insulated Vir Copper Wire , 25W/30W Led Street Light Fitting Board , 2.5 Flex Wire , 1/18 Copper Wire , 3/20 Copper Wire , 7/16 Copper Wire , 7/20 Copper Wire , Hook Up Wire , Insulation Tape , 250 W Sodium Lamp , 250 W Sodium Holder , 250 W S.V Choke , 250 W S.V Ignator , 250 W S.V Capacitor , 250W Sodium Street Light Fitting , 250W Sodium Street Light Cover , 250W Sodium Street Light Gi Pipe , 250W Sodium Street Light Pipe Cover , 150 W Sodium Lamp , 150 W S.V Choke , 150 W S.V Ignator , 150 W S.V Capacitor , 250W Metal Halide Choke , 150W Metal Halide Choke , 150W Metal Halide Lamp , 150W Metal Halide Ignitor , 150W Metal Halide Capacitor , 250W Metal Halide Lamp , 250W Metal Halide Ignitor , 250W Metal Halide Holder , 250W Metal Halide Capacitor , 400W Metal Halide Choke , 400W Metal Halide Lamp , 400W Metal Halide Ignitor , 400W Metal Halide Capacitor , 400W Metal Halide Holder , 40A Isolator , 40A Contactor , 63A 4 Pole Mcb Switch , 63A S/P Mcb Switch , 63A 6 Way Connector , 63A Isolator 4 Pole , Repair Work & Service Charges For Highmast Flood Light Fittings (Per Pole) , 3/20- 2 Core Aluminium Wire , 4 Sq.Mm 3 Core Flat Cable , 2.5 Sq.Mm 3 Core Flat Cable , 1.0 Sq.Mm Multi Standared Flexible Copper Cable , 1.5 Sq.Mm Multi Standared Flexible Copper Cable , 2.5 Sq.Mm Multi Standared Flexible Copper Cable , 4.0 Sq.Mm Multi Standared Flexible Copper Cable , 24X24 Meter Board , 18X18 Meter Board , 12X12 Meter Board , 1/18 Pvc Insulated Vir Aluminium Wire , 3/20 Pvc Insulated Vir Aluminium Wire , 7/20 Pvc Insulated Vir Aluminium Wire , 7/20 Aluminium Wire , 3/20 Aluminium Wire , 70 W Sv Lamp , 70 W Sv Choke , 70 W Sv Holder , 70 W Sv Capacitor , 70 W Sv Ignator , 1X40 W Street Light Fitting Glass , 40 W Street Light Fitting Side Plate , 16 Amps Main Switch , 32 Amps Main Switch , 63 Amps Main Switch , 32 Amps Main Switch (Dp) , 5000 W Street Light Automatic On/Off Timer Switch , Photanic Intellingent Automatic Street Light Controlling Divice Switches Timer / Sensor On/Off Including Fixing All Complete Set , 16 Amps Fuse Carrier , 32 Amps Fuse Carrier , 63 Amps Fuse Carrier , 100 Amps Fuse Carrier , 1X40 W Street Light Fittings Set With Clamp Set (2 Sets), Bolt-Nut, 20Mm Gi, Bend Pipe, 3/20 Wire , 1/40 W Street Light Fittings Set With Heavy Duty Copper Choke, Starter, Tube , Led Street Light Fittings Accessories Clamp Set (2 Sets) 32 Mm Bend Pipe, Bolt-Nut Wire , 25W Led Street Light Fitting Pcb & Drive Including Service Charges , 45W Led Street Light Fitting Pcb & Drive Including Service Charges , 18W Led Lamp , 20W Led Lamp , 23W Led Lamp , 30W Led Lamp , 36W Led Lamp , 40W Led Lamp , 50W Led Lamp , 72W Led Lamp , 100W Led Lamp , 120W Led Lamp , 36W Cfl Lamp , 36W Cfl Choke , 1X36W Cfl Street Light Fitting , 36W Cfl Pipe , 36W Cfl Fitting Clamp , 36W Cfl Light Cover , 25/30 W Led Street Light Fitting Board , 25/30W Led Street Light Fitting Drive , Timer Clock
Contract Date: Mar 31, 2026 Contract Value : 2.09 Lakh
Local Bodies No of Bidders 4
39.
Public Administrative Department #9912652 AOC
Supply Of Street Light Materials In Hulical Town Panchayat (2025-26) , Street Light Materials , 40 W Tube Light , 40 W Tube Light Starter , 40 W Copper Choke , 40 W Electronic Choke , Tube Light Side Holder , 40W Tubular Fluoresent Super Brigth Lamp , 40W Ballast For Fluoresent Lamp , 40W Planet Electronic Ballase Heavy Duty , 1 X 40 W Street Light Fitting Cover (Cylinder) , 1 X 40 W Street Light Fitting Cover (Square) , 1 X 40 W Street Light Fitting , 1 X 40 W Street Light Fitting Pipe , 1 X 40 W Street Light Fitting Clamp , 1 X 40 W Street Light Fitting Side Holder , 20W Led Street Light Fitting Set , 25W Led Street Light Fitting Set , 30W Led Street Light Fitting Set , 36W Led Street Light Fitting Set , 45W Led Street Light Fitting Set , 50W Led Street Light Fitting Set , 60W Led Street Light Fitting Set , 100W Led Street Light Fitting Set , 150W Led Street Light Fitting Set , 1/18 Pvc Insulated Copper Wire , 3/20 (2.0 Sqmm) Flex Copper Wire , 3/20 Pvc Insulated Vir Copper Wire , 7/16 Pvc Insulated Vir Copper Wire , 7/20 Pvc Insulated Vir Copper Wire , 25W/30W Led Street Light Fitting Board , 2.5 Flex Wire , 1/18 Copper Wire , 3/20 Copper Wire , 7/16 Copper Wire , 7/20 Copper Wire , Hook Up Wire , Insulation Tape , 250 W Sodium Lamp , 250 W Sodium Holder , 250 W S.V Choke , 250 W S.V Ignator , 250 W S.V Capacitor , 250W Sodium Street Light Fitting , 250W Sodium Street Light Cover , 250W Sodium Street Light Gi Pipe , 250W Sodium Street Light Pipe Cover , 150 W Sodium Lamp , 150 W S.V Choke , 150 W S.V Ignator , 150 W S.V Capacitor , 250W Metal Halide Choke , 150W Metal Halide Choke , 150W Metal Halide Lamp , 150W Metal Halide Ignitor , 150W Metal Halide Capacitor , 250W Metal Halide Lamp , 250W Metal Halide Ignitor , 250W Metal Halide Holder , 250W Metal Halide Capacitor , 400W Metal Halide Choke , 400W Metal Halide Lamp , 400W Metal Halide Ignitor , 400W Metal Halide Capacitor , 400W Metal Halide Holder , 40A Isolator , 40A Contactor , 63A 4 Pole Mcb Switch , 63A S/P Mcb Switch , 63A 6 Way Connector , 63A Isolator 4 Pole , Repair Work & Service Charges For Highmast Flood Light Fittings (Per Pole) , 3/20- 2 Core Aluminium Wire , 4 Sq.Mm 3 Core Flat Cable , 2.5 Sq.Mm 3 Core Flat Cable , 1.0 Sq.Mm Multi Standared Flexible Copper Cable , 1.5 Sq.Mm Multi Standared Flexible Copper Cable , 2.5 Sq.Mm Multi Standared Flexible Copper Cable , 4.0 Sq.Mm Multi Standared Flexible Copper Cable , 24X24 Meter Board , 18X18 Meter Board , 12X12 Meter Board , 1/18 Pvc Insulated Vir Aluminium Wire , 3/20 Pvc Insulated Vir Aluminium Wire , 7/20 Pvc Insulated Vir Aluminium Wire , 7/20 Aluminium Wire , 3/20 Aluminium Wire , 70 W Sv Lamp , 70 W Sv Choke , 70 W Sv Holder , 70 W Sv Capacitor , 70 W Sv Ignator , 1X40 W Street Light Fitting Glass , 40 W Street Light Fitting Side Plate , 16 Amps Main Switch , 32 Amps Main Switch , 63 Amps Main Switch , 32 Amps Main Switch (Dp) , 5000 W Street Light Automatic On/Off Timer Switch , Photanic Intellingentautomatic Street Light Controlling Divice Switches Timer / Sensor On/Off Including Fixing All Complete Set , 16 Amps Fuse Carrier , 32 Amps Fuse Carrier , 63 Amps Fuse Carrier , 100 Amps Fuse Carrier , 1X40 W Street Light Fittings Set With Clamp Set (2 Sets), Bolt-Nut, 20Mm Gi, Bend Pipe, 3/20 Wire , 1/40 W Street Light Fittings Set With Heavy Duty Copper Choke, Starter, Tube , Led Street Light Fittings Accessories Clamp Set (2 Sets) 32 Mm Bend Pipe, Bolt-Nut Wire , 25W Led Street Light Fitting Pcb & Drive Including Service Charges , 45W Led Street Light Fitting Pcb & Drive Including Service Charges , 18W Led Lamp , 20W Led Lamp , 23W Led Lamp , 30W Led Lamp , 36W Led Lamp , 40W Led Lamp , 50W Led Lamp , 72W Led Lamp , 100W Led Lamp , 120W Led Lamp , 36W Cfl Lamp , 36W Cfl Choke , 1X36w Cfl Street Light Fitting , 36W Cfl Pipe , 36W Cfl Fitting Clamp , 36W Cfl Light Cover , 25/30 W Led Street Light Fitting Board , 25/30W Led Street Light Fitting Drive , Timer Clock
Contract Date: Mar 31, 2026 Contract Value : 1.71 Lakh
Local Bodies No of Bidders 2
Contract Date: Ref. Documents Contract Value : 14.00 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
41.
Educational and Research Institute #9832816 AOC
PROCUREMENT OF MACHINERIES, INSTRUMENTS, TOOLS AND EQUIPMENTS ETC. RELATED TO ELECTRICAL ENGINEERING AND ELECTRONICS AND TELECOMMUNICTION ENGINEERING LABORATORIES AND WORKSHOPS OF MATHABHANGA GOVERNMENT POLYTECHNIC, MATHABHANGA, COOCH BEHAR, WEST BENGAL- 1 ANALOG ELECTRONICS LAB-I (3RD SEM) 2 50 MHz Dual Channel CRO• Automatic Measurements of Signal Parameters like .Pk-Pk, Average, Max. , Min., rms, top etc. Voltages and Frequency, Period,Width,Duty Cycle, Rise Time, Fall Rime • Waveform and Set up storage facility.• Colour Display. • Advanced features like sequential acquisition of up to 1000 trigger events should be possible.• Standard USB Host & Device Connectivity. • Standard 23 Automatic Measurement andMath Function Including FFT.• Education student Lab guide and professor slide set.DETAILED TECHNICAL SPECIFICATIONS:-a)No. Of Channels:2b)Bandwidth :50 MHzc)Maximum Input:400 V (peak ac + dc) d) Sample Rate :1 GSa/sece)Waveform Update Rate : 400 Waveforms/secf)Memory : 16 Kpts/Ch.g)Time Base : 5nsec / div. To 50 sec./div.h) Resolution : 8 bitsi) Display: 5.7 inch Colour QVGA TFT LCD Display.j)Trigger Modes: Force, Edge, and Video, Pulse width.k) Built In Interface : Standard USB 2.0 (Host and Device)l)Power Supply: 230 V AC Supply, 50 Hz. 3 Function Generatori)Itshould be a waveform / function generator which can be upgraded to an arbitrary waveform generator . It may also have the feature upgrade the frequency of operationii) Should have low harmonic distortion and jitter.DETAILED TECHNICAL SPECIFICATION:--• Frequenc : 1Hz. to 20 MHz for Sine , Square and PulseWaveforms and 1 Hz. to 20 MHz. for Noise• No. of Channels: 1• Frequency Resolution : 1Hz.• Amplitude : 1 mVpk-pk to 10 v (pk - pk) in 50 ohms. • Duty Cycle for Pulse : 0.01 % to 99.99 %• Standard Waveforms: Sine,Square,Ramp,Pulse,Triangle,•Operating Modes: Continuous,Modulate,. .• Modulation Types: AM,FM,PM,FSK,BPSK,PWM• AM : Source both Internal & External, Depth 0 to 120 %With 0.01 % resolution.• FM : Source both Internal & External, Deviation 1Hz to 15 MHz• PM: Source both Internal & External, Deviation 0 to 360 deg C.• PWM : Source both Internal & External. Deviation 0 % to 100 %.• Power Supply : 230 v,50 Hz. ac. 4 Digital MultimeterDC Voltage:400mV to 1000V , AC Voltage: 400mV to 1000V,DC Current: 4mA to 10A, AC Current: 4mA to 10A, Resistance: 100 ohm to 40Mohm, Resistance: 100 ohm to 40Mohm,Capacitance: 4nF to 200µF, Duty Cycle: 0.1% to 99.9%, Frequency: 10Hz to 10MHz, Temperature: 20oC to 750oC,Transistor Test: Yes (for NPN & PNP), Diode Test: Yes, Continuing Buzzer: Yes, Power Supply: 9V, Manual and Auto ranging,Display: 4½ Digit 5 To study the V-I characteristics of UJT Trainer kitVariable DC Power Supply 1.2V to 12V/500m,A DC Power Supply for DPM 5V/500m,A UJT (2N2646) UJT Characteristics UJT Relaxation Oscillator with two different Timing Capacitors ,DigitalMeters for Measuring Voltage and Current ,Set of Patch Chords & User Manual 6 To study the input and output characteristics and to find the h-parameters of a BJT for : —(a) C-E configuration,(b) C-C configuration,(c) C-B configurationHARDWARE SPECIFICATIONS :Dual Variable DC Power Supplies 0V to 12V/500mA and0V to 15V/500mA DC Power Supply for DPM 5V/500mAIndependent Base Limiting Resistors - 2 Nos.(low value) Independent Collector Resistor - 1 No. Transistor( NPN Type SL100) .All Inputs/Outputs through 2mm Sockets set with provision of Digital Multimeter for measuring input and output. 7 ANALOG ELECTRONICS LAB-II (4TH SEM) 8 Feedback Amplifier Trainer12 V DC supply with +/- 10%accuracy,configurable circuit,Inbuilt sine wave generator with frequency range 10 Hz to 10 KHz rangeand Amplitude variation 10mV to 4V, NPN transistor. Voltage Series & Shunt and Current Series & Shunt configurable operation. 9 Oscillator Trainer KITi) Hartley, Colpitt ,Wien Bridge Oscillator Trainer kit : i) NPN Transistor ii)On boardoscillator section,separate tank circuit (iii)Biasing Voltage :+12 V , -12 V ,+12V SMPS Adaptor provided with the trainer for power supply.Designed by considering all the safety standards. Provided with an extensive manual.Power Supply to Kit: 230VAC,50Hz, All interconnections are made using 2mm banana Patch cords 10 To determine the following characteristics of op-amp: —a) input offset voltage, b) slew rate, c) non-inverting gain, d) inverting gain e) adder, f) subtractor, g) differentiator, h) integratorandi) voltage followerTo adjust offset null, setup the closed loop amplifier using IC741 op-amp also to (a) dc gain (b) ac gain. The set complete with +/-12V DC regulated power supply with milli voltage source, Null arrangement and 2V/20V dual range digital voltmeter , In built sine wave,triangular wave & square wave Generator of1 KHz, 15V Vpp (approx.), DC Power Supply : 0 - 5 V (vary through (2No.) rotary switch for specific voltage level 11 DIGITAL ELECTRONICS LAB (3RD SEM) 12 Complete setup to implement encoder, decoder ,multiplexer andde-multiplexer5V D.C. at 100mA, IC regulated power supply,21 Input Switches for data input,IC For Multiplexing 74150 is provided on board with Combinational Circuit, IC For Demultiplexing 74154 is provided on board with Combinational Circuit, One Not Gate is provided on board using 7404 ,16 Output LEDs with driver circuit to observe the output of Multiplexer Demultiplexer, A Pulser to provide the pulses manually for triggering,230 V ±10% at 50 Hz A.C. Mains,necessary patch cords and user mannuals. 13 Complete setup to design / construct parity generator, checker andcomparatorDC Regulated Power Supply 5 VDC/150 ma,5 SPDT switches provided for selecting logic ‘1’ & logic ‘0’,2 output indicators,Sufficient no of 4mm Patch Cords for Interconnection,Power Cords 230v, 50Hz,necessary patch cords and user mannuals. 14 Complete setup to design / construct binary synchronous and asynchronous counterTrainer kit for binary Synchronous and Asynchronous counter. with power supply, display unit, patch cords, manuals and necessary IC. 15 Digital I.C TesterUniversal IC tester: 40 pin DIP ZIF socket, 50 cherry keys Key pad and 16 X 2 LCD Display, suitable for testing of Analog IC, Digital IC and 7-segment display. 16 A/D & D/A Converter TrainerFEATURESAnalog To Digital Converter• 8-bit descrete ADC•12-bit monolithic ADC IC•On-board signal generator with adjustable amplitude levels•On-board LED bank to observe digital outputs•Power supply : +5V, ±12V GND•Interconnection is provided by 2mm connectors•Experimental manualDigital To Analog Converter•8-bit binary weighted resistors DAC•8-bit ladder type D to A converter•8-bit D to A converter using monolithic IC•Simple construction using Op-Amp and resistors•Onboard switches are provided for digital pattern generation•8-bit digital inputs ranges from 00 to FF•Variable frequency counter to study the settling timeSPECIFICATIONS•8-bit binary weighted and 4-bit ladder type DAC are constructed using discrete components•8-bit monolithic DAC having settling time in the range of ns, wide power supply range, low power consumption, full scale error ± 1LSB•8-bit digital ramp ADC constructed using discrete components•12-bit monolithic ADC having conversion time in the range of μs, industry standard pin out, wide input range•8 onboard switches to provide digital inputs to DAC•8-bit counter running on external clock frequency to study settling time of DAC• Built inlow frequency clock generator•1 KHz sine wave with adjustable amplitude level•Onboard variable DC voltage source for studying unipolar and bipolar modes of ADC •12 output LEDs to observe ADC outputs•ADA operates on DC power supply (+12V,-12V,+5V and GND)•Interconnection is provided by standard 2mm connector•Extensive experimental manual is provided with the kit EXPERIMENTSAnalog To Digital Converter• To study and measure resolution of ADC•To measure the conversion time of the ADC•To study full scale adjustment for unipolar and bipolar signals•To study the working of ADC 17 NETWORK ANALYSIS LAB ( 3RD SEM) 18 To study the series and parallelresonant circuitIndependent Resistors - 3 Nos. ,Independent Capacitors - 3 Nos.,Tapped Inductance. All Inputs/Outputs through 2mm Sockets Set of Patch Chords & User ManualWITH SIGNAL GENERATOR, COUNTER, DIGITAL METERS FOR INPUT & OUTPUT and user manual 19 To test and to measure the cut –off frequencies of the following: —(a) constant k-type low pass filter;(b) constant k-type high pass filterTwo Independent Passive LC Filter Networks (LPF & HPF) All Inputs/Outputs through 2mm SocketsSet of Patch Chords & User Manual 20 To study standing wave pattern for a transmission line of finite length with:(a) open termination,(b) shorted termination andmatched termination. 2.To measure the attenuation constant and phase shift constant for matched terminationTransmission Line Trainer Features:* 30-300 Mhz sweep source with detector* Calibrated attenuator* Displays standing waves/maxima-minima on CRO* Uses actual coaxial lines rather than simulated ones.* Impedance matching.* Measures VSWR, reflection coefficient, characteristic impedance, velocity of propagation, dielectric constant and signal attenuation in TDR.* Measure parameters of 50, 75 and 300 Ohms cables* Study Time Domain Reflectometry.* Study location and nature of discontinuities,Open/short, mismatched terminations, etc.* Offers a complete view of the transmission line in analog and digital domains, which is essential for complete understanding of transmission line behavior.Technical Specifications:A. Frequency Domain AnalyzerFrequency range : 30-300 MHz typical LCD Display. Level : 100mV p-p Attenuator 50 Ohms : 0.5, 1, 2,4, 8,15 dB,Output Impedance : 50 Ohms Scope out : X-Y output to scopeB. Resistive Impedance Analyzer ,Characteristic Imp. : upto 800 ohms ,Display : LCD C. Time Domain ReflectometerPRR Short range : 10MHz typical,Pulse width : <10ns typical, PRR Long range : 100KHz typicalAmplitude : 1V nominal, Output Impedance : 50 OhmsAccessories:Lengths of 50 ohms and 75 ohms coaxial cable, 300ohms, parallel line, lossy line, Tee connectors, ,Standard load of 50and 75 ohms, Various capacitive and inductive loads, shorts, Balun 1:1 & 1:4, Operating manual, Mains cord 21 COMPUTER PROGRAMMING LANGUAGE LABORATORY (3RD SEM) 22 Computer Programming Language LaboratoryTURBO C++ Software 23 MICROPROCESSOR LAB (4TH SEM) 24 8085Microprocessor Trainer KitHigh performance 8085A CPU operating at 3 MHz.16 K powerful monitor FIRMWARE expandable to 32 K. 64 K user RAM. Expanded RAM accessible using bankWrite protect facility for RAM. 3.6 V Ni-Cad battery back up. Versatile Keyboard/Display controller using 8279. 24 highly reliable dual function keys. 6 digit seven segment LED display.Parallel I/O lines available through two 8255 chips. Serial I/O through 8251 USART, with on-board level shifters 1488,1489.Programmable communication parameters. Built-in audio cassette interface.3 channels of 16 bit timer/counters from 8253.Powerful 8085 interrupt capabilities. On-board EPROM programmer with ZIF socket for programming 2716 to7512 EPROMs and various EEPROMs. Normal and intelligent programming modes.On-board ADC,DAC, opto-isolator, reed relay and miniature speaker. On-board logic probe.Single stepping, break pointing and machine cycle single stepping facility. Monitor functions can be called through software interrupts. Large collection of application software provided. All address, data and control lines from the CPU, buffered and brought out on 50 pin connector. Additional Stepper motor of specification:Shaft type: 5 mm DCurrent rating: 1200 mA2Voltage rating: 4 VHolding torque: 44 oz·inSteps per revolution: 200Resistance: 3.3 Ohm2Inductance per phase: 2.8 mHNumber of leads: 6Lead length: 30 cm 25 Microprocessor 8086 Trainer KitINTEL 8086CPU AT 4.77 MHZ CLOCK SPEED,16KB for monitor EPROM upgradable to 64kb16KB RAM expandable to 64KBBattery backup provision for RAM upto 64KB16 x 2 (or) 20 x 4 Alphanumeric LCD display101 keys IBM compatible keyboard24 TTL I/O lines brought out to two nos., of 26 pin FRC connector1 number of standard RS232C compatible serial port brought out to a pin D type male connector.3 channel 16 bit counter/timer using 8253.Fully buffered address data and control signals terminated at a 50 pin header(VXT BUS) for interfacing VBMB seriesof experiment boards and bus expansion.8 no’s of interrupt lines are terminated at a 10 pin connector.Kit operates with a single +5V/DC supplyThe kit and the power supply are mounted on a attractive light gray color fiber glass cabinet with fiber glass top cover.Built-in line assembler & DisassemblerPowerful debugging monitor to develop user program. 26 ELEMENTARY COMMUNICATION ENGG. LAB 27 To study the amplitude modulation and demodulation Ttrainer kit Features of Amplitude Modulation and Demodulation Trainer:On-board message signal with variable Amp/Freq On Board carrier signal with variable Amp/Freq AM Modulation using MC 1496 IC Demodulation using Diode Detector and LPF,6th Order LPF,Op Amp Based Variable AmplifierInternal Power Supply +5V , +12V/ 500 mATechnical Specification :Message Signal:Sine wave Frequency 100 Hz to 2.8 KHz, Amplitude 0 to 3VCarrier Signal: Sine wave Frequency-28 KHz to 108 KHzAmplitude 2V,Modulation : Balanced ModulatorAmplifier : Op Amp BasedDemodulation : Diode Detector & LPFLow Pass Filter : 6th Order LPFSupply Voltage (Board) : +12V, +5V / DCSupply current : 100 mA (Minimum)Input Voltage : 230 V/ 50 Hz ACInterface connectors : 2mm socket 28 AM/FM Radio Receiver kitFrequency range: 400KHz ~ 1.5MHzIntermediate frequency: 455KHzInputs: RF signalOutput IF frequency: 455KHz adjustableIF filter: Dual tune LC, RF amplifier with variable gain ,Mixer (frequency converter),Local oscillator:Output Signal: Sine waveFrequency range: 400KHz ~ 1.5MHz ,Amplitude: Adjustable from 0Vpp ~ 2VppOutput impedance: 50 Ohm ,1st and 2nd IF amplifierCentral frequency: 455KHz, Load impedance: Variable R-L-CGain: 40db with automatic gain control, Diode envelope detectorDetection of the envelop with variable RC filter. Audio output:Amplifier with audio jack, Audio amplifier gain: 26Db, Receiving media :MW coil antennaFM radio receiver, Reception range: 88MHz ~ 108MHz with continuous tuningTuning circuit: Using GANG capacitorIntermediate frequency: 10.7 MHz with ceramic filterEXPERIMENTS:Study of double sideband AM reception using envelope diode detector,Study of single sideband AM reception using product detector,Study of image frequencies,Study of adjustment of receiver tuned circuits,Voice reception using DSB/ SSB AM receiver (super heterodyne receiver)Effects of switch faults FM detection output level: 77.5Vrms (typical)FM detection output distortion factor: 0.3% (typical)Audio amplifier: Gain up to 46DbReceiving media: Adjustable telescopic antennaPower supply: -12V,+12V,+5V,GNDOutput volume regulation, output load impedance of 8 OhmEXPERIMENTS AM radio receiverTo study AM radio receiverTo study of image frequencies for AMFM radio receiverTo study FM radio receiverTo measure the frequency response of Audio amplifier 29 Pulse code Modulation and Demodulation system trainerInbuilt variable DC and 1 kHz AC Modulating Signals, Facility for applying external AC or DC Modulating Signal, Modulating circuit consists of a Positive Clamper, Sample and Hold (S and H), Analog to Digital Converter (ADC), Parallel to Serial Converter and Control Signal Generator, Observation of binary coded analog information by the LED status for both Modulation and Demodulation, PCM Modulation technique using IC, Built-in Pulse Code Demodulation circuit using a Serial to Parallel Converter and Parallel Shift Register DAC, Low Pass Filter for both AC & DC, Observation of Modulated & Demodulated waveform, Provision to monitor output on CRO, Clock to be provided from the Pulse Code Modulator to Demodulator circuit, Built-in IC based DC Regulated Power Supply with indication for power ON & fuse, 4 mm Patch Cords – 4 nos, Supply required 230V, 50 Hz and 1 phase AC, Comprehensive instruction manual complete with theory and operating details. 30 Frequency Modulation andDemodulation kitFM Modulators :Audio Oscillator : Sine wave (10Vpp adjustable) Frequency (300 Hz - 3.4 KHz) FM Modulators : 3 nos. • Reactance Modulator : Carrier Frequency - 455 KHz (± 3KHz) Varactor Modulator : Carrier Frequency - 455 KHz (± 2KHz) VCO Based Modulator : Carrier Frequency - 10 KHz - 200KHz (adjustable) ,Mixer / Amplifier adjustment FM Demodulator:Detuned Resonant DetectorQuadrature DetectorFoster-Seeley DetectorRatio DetectorPhase-Locked Loop Detector (IC HEF4046 based)Phase-Locked Loop Detector (IC LM565 based), Low Pass Filter : 3.4 KHz Cut off Frequency Amplifier (with adjustable gain) 31 DPCM & ADPCM MODULATION / DEMODULATION KITDPCM & ADPCM MODULATION / DEMODULATION KITOn Board Signals:. Frequency: 500KHz, Amplitude: 0 to 4 v pp 32 CONSUMER ELECTRONICS LAB (4TH SEM) 33 Black & White TV Trainer kit with provision of fault findingSystem: CCIR-B, 625 lines, Power supply :230V Ac, 50 Hz, Regulation range170v Ac to 270v Ac.,Power consumption :70 watts,Gain Limited sensitivity:55 dB for Video & 25 dB for AudioSound output :2.0 watts maximum. Screen size :20 Diagonal. Channel :VHF 2 to 12, UHF 21 to 68,S-band and Hyper-band. Isolated shockproof chassis. Sections:Electronic tuner, VideoI.F Section, Sound I.F, Video amplifier, Horizontal oscillator, Horizontal driver and EHT, Verticaloscillator, and output, S.M.P.S power ,Controls: Volume, tone, Brightness, contrast. Distortion :10 to 15% in Live program due to expanded P.C.B. All parts are soldered on Tags on SINGLE PCB of size 19x15” with complete circuit diagramSCREEN PRINTED in different colors with FAULT CREATING FACILITIES to create more than 25 faults. Standard Accessories : 1. Frame with PCB mounting.2. Picture tube fitted in wooden cabinet 3. A Manual having 20 practical. 34 DTH TV and SET TOP BOX TRAINER KITPower supply 230 V ,50 Hz, Input frequency: KU Band, Output frequency: 950-1450 Mhz.Noise temp: 35 degree,DISH ANTENA ,LNBIF FREQUENCY: 70 MHz 35 Colour TV Trainer with provision of fault findingStandard : CCIR-B-PAL-G, 625 Lines Channels : 230, 2 - 4 VHP I (VL), 5 - 12 VHP III (VH), 12 - 100 : BAND IV & V, else : S BAND & HYPER BAND Picture Tube Size : 36 cms. Diagonal RF Input Impedance : 75 W (Ohm) 36 DIGITAL & MICROWAVE COMMUNICATION ENGG. LAB 37 Spectrum AnalyzerFrequency range:9 KHz to 26.5 GHz,Phase noise :-102dBc/Hz, Max third order dynamic range, 1 GHz: 111dB, Displayed average niose level,1GHz:-163dBm,Standard attenuator range/step:50dB/10dB,70dB/10 squaredb,Overall amplitude accuracy:+/- 0.50dB 38 Antenna Trainer 86 - 860 MHZSPECIFICATIONS:Radiation pattern plotting software• Stepper motor controlled receiver stand.Antenna Measurement System:RF Source•Source types :PLL Synthesized with integrated VCO• Frequency range :100MHz to 3GHz• Dynamic range :85dBm• Transmitted power min:-50dBm• Transmitted power max:+5dBm • Impedance :50W / SMA RF Detector• Detector type: logarithmicdetector• Frequency range : 1MHz to 8GHz• Resolution: 0.1dB• Dynamic range : 85dB (±3dB)• Noise level : -90dbm• Impedance: 50W /SMA• Representation of RF level : dBmDisplay•128x64 Graphic LCD Display with backlit. Keypad•15 Key Membrane Keypad for user entry.Stepper motor controller•1.80 Resolutions.List of Standard 22 Antenna Suppliedwith the setupWire Antenna1.Monopole Plane base ground2.Dipole (2nos.) 3.Yagi4.Folded Dipole 5.Vee Dipole6.Rectangular Loop 7.HelicalMicrostrip Antenna 1.Planar Dipole 2.Planar Monopole3.CMSA 4.TMSA5.2X1 ARRAY 6.Annular ring7.Chip Antenna8.RMSA9.RMSA- Circular PolarizedAperture Antenna 1.E- Horn2.Open ended Waveguide Rectangular Array Antenna 1.Broadside Array2.Collinear ArrayReflector Antenna 1. Corner reflectorSOFTWARE• Radiation pattern plotting and analysis software suitable for windows environment Antenna PositionerThe Transmitter and Receiver Antenna stand is made of special material which is inhert to EM frequency and it has engraved height and angle scale on It. It has facility to adjust the height and level. Universal plug and fix Antenna mounts are provided to hold the antenna assembly in vertical and horizontalorientation for co and cross polarization.ACCESSORIES • SMA (M) to SMA (M) 50W flexible cable : 02nos• USB cable ( Male A to Male B): 01no• 3 Pin 6 Amp Power chord: 01no • Manual : 01no • Software on CD: 01no EXPERIMENTS• Measure the variation of field strength /inverse square law• Prove the reciprocity theorem of antenna• Plot Radiation pattern of WIRED Antenna Omni directional antenna• Plot Radiation pattern of all Aperture Antenna• Plot Radiation pattern of all Reflector Antenna• Plot Radiation pattern of all Array Antenna• Measure co-polarization, cross polarization 39 Microwave Test Bench (KLYSTRONBased)Klystron Power Supply: Specifications:Input Voltage -230V+/- 10%, 50Hz AC, Beam supply- Voltage:200-450V continuously variable; Current:Regulation: better than 0.5% for +/-10% variation in mains supply voltage; Ripple: less than 5mV rms ,Repeller Supply -Voltage:-10V to -270V continuously variable with respect to klystron cathodeRegulation: better than 0.25% for +/-10% variation in mains supply volt , Heater Supply - 6.3V DC (regulated)Modulation- Square Wave : Frequency 500Hz to 2000Hz; Max. Amplitude- +110V peak to peak, Amplitude and frequency continuously variable; Sawtooth- Frequency 50Hz to 150Hz; Max. Amplitude- 60V peak to peak, Amplitude and frequency continuously variable.VSWR Meter: (Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Power : 230 Volts AC, 50Hz, mains supply) 40 ASK / PSK / FSK Modulation And Demodulation KitFEATURES•VLSI based design •Separate component and operational area •Acrylic cover for component safety •Modular organization of circuit functions •Test points to access signals at every stage of circuit operation •Multimedia based interactive e-manual Data Simulator: Onboard 8-bit variable NRZ-L pattern,Crystal Oscillator: 32.768 MHz,Data Clock: 256 KHz,Data Format: NRZ (L),Onboard Carrier Sine Waves : 1MHz (0°), 1MHz (180°), 500 KHz (0°),Power Supply: +12V, -12V, +5V, GND. 41 Microwave Test Bench (GUNN Based)Gunn microwave test bench:Gunn Power Supply (0 - 12 Volts variable,1 Amp. Max,Modulation Frequency: 1KHz +/- 10% (900-1100 Hz),Output Connector: BNC(F) for Gunn Oscillator & TNC(F) for Pin Modulator,Modulation: Square Wave, Frequency : 500Hz to 2000Hz)• Gunn Oscillator • Isolator• PIN modulator• Variable attenuator • Detector Mount• SWR meter(Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Powe : 230 Volts AC, 50Hz, mains supply) 42 1 GHz spectrum Analyser1 GHz spectrum Analyser with tracking generatorFrequency range: 150 KHz to 1000 MHzFreqency Resolution: 1 KHz CF entry 40 Hz sweep resolution at 2 KHz per Division,Frequency Display: 61/2 digitFrqency Control: Digital Phase LockResolution Bandwidth: 3 KHz, 30 KHz, 220 KHz, 4 MHz. 43 INDUSTRIAL ELECTRONICS LAB -I (5TH SEM) 44 Trainer Kit to study Reverse Recovery Characteristics of Power DiodesThe single Board trainer Kit should contain IC Regulated Power Supply, Different types power diodes, Digital Ammeter and Voltmeter and other necessary passive components 45 To study drive circuit of SCRIsolated 230 V/40 W AC Power Supply1.2 V to + 15 V/500 mA DC Power Supply* 0-18 V/500 mA,50 Hz, AC Power Supply* Variable frequency triggering pulses* DC Gate signal control, Pulse gate signal * Synchronous AC gate control signal through DIAC* UJT Triggering* 10:1 On- board resistive attenuator * Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 46 To study a single phase rectifier—output waveform with phase control circuitTrainer Kit to study Single Phase Full wave Bridge Rectifier for fixedDC output, Half Controlled and fully controlled rectification facilities with R and RL, loads 1000 Ohms 10 Watts, 14 ma @ 0.05 A inductive loads.The Single Board Trainer Kit contains :(i) Source for rectification of 4 to 24 V DC fixed and variable output @ a max of 500 ma helps to construct and study Series and Parallel resonance Circuit.(ii) Four Diodes and 4 SCRs in bridge configuration with gradual firing controls and necessary capacitive, inductive and Pie filter components.(iii) Digital Ammeter and Voltmeter. 47 To study a polyphase rectifierIsolated 230 V/40 W AC Power Supply Isolated stepped down 3 PH supply. * 3 Phase diode rectifier in open condition*Provision for Load& CRO output.* Electronic phase sequence finder.*Set of Patch Chords & user Manual 48 INDUSTRIAL ELECTRONICS LAB-II (6TH SEM) 49 Servo Regulator Stabilizer Study Kit500VA Servo stabilizer , 2 Amp Variac, Digital input & output meters, Lamp load, Set of Patch Chords & userManual. 50 To study a Jones chopperIsolated 230 V/40 W DC Power Supply, + 5 V/500 mA DC Power Supply* SCR Jones chopper* Gate firing pulses for Jones Chopper* 10:1 On-board Resistive Attenuator* Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 51 To study speed control of induction motor by voltage and frequency variationV/F CONTROLLER 1 HP, AC SQ. CAGE IND. MOTOR 1 HP,DIGITAL VOLT & AMMETER. 1 PHASE I/P & 3 PHASE O/P,3 PH & 1PH MCB PROTECTION 52 To study the speed control of DC motor by:(a) varying field current keeping armature voltage constant; and,(b) varying armature voltage keeping field current constant DC SHUNT MOTOR (FULL COPPER WINDING) .5 HP WITH BASE MOUNT FRAME 1 No VARIAC CONTROLLED 2 DC POWER SUPPLY ( 1 FOR FIELD & 1 FOR ARMATURE)DC VOLT & AMMETER DIGITAL………4 NosPANEL MOUNTED RPM METER………1 No.WHITE BAKELITE FRONT WITH CONN. DIAGRAM & WOODEN SAFETY BOX.METAL FRAME TABLE (Ply board with sun mica) CUM STAND FOR PANEL 53 Power Electronics Devices Trainer KitShould have Built in power supplyDC supply : +/- 12V, 500mA,Power supply 17V / 750mA,Regulated 13.5V/3A O/P mustbe provided as 12V Battery charging supply. Isolated DC supply +12V/ 300mA with isolated common.On board Inverter transformer of Primary : 230V & Secondaries 12-11-0-11-12/3AOn board Lamp load of 15W (100W) should be provided.AC supply : 230V AC line voltage must be made available on two banana 4mm socketsMust have Two pulse transformers of 1:1:1 are provided for isolation & supplying firing pulsesalong with required DC Power supply to experiment panel under test through 15 pin female ‘D’connector.R-L-C Load PanelMust have Load resistor of 10W / 40W --- 1no.Must have Centre tapped 3A choke 4mH/ 16mH each ----2nos.Must have Commutation capacitors of 10mF/100V -------4nos.Must have AC Paper capacitor of 4mF/440V ---1no. 54 PLC Trainer (EXPERIMENT 1-Use of simulation package for different function of PLC. EXPERIMENT 2- Verify function of logic gates by using PLC. EXPERIMENT 3- Write and verify ladder program for motor ON-OFF Control with two push button)HARDWARE SPECIFICATION:TTL Input Switches : 8 Nos,TTL Momentary Switches : 8 Nos., Proximity Switch : 1 No.,Optical Transducer (two state) : 1 No., Programmable LEDs : 8 Nos., Analog input 0 to 5V DC : 8 channels, Analog output 0 to 5V DC : 1 No., 4 to 20mA Transmitter : 1No., 4 to 20mA Receiver : 1No., Current Meter : 25mA FSD 1No.,Voltmeter : 10V FSD 1 No., Piezo Electric Alarm : 1 bit.Built-in power supply.Dedicated I/O interface card suitable for IBM computer suitable for ISA slot. SOFTWARE SPECIFICATION:This is a GUI based LADDER LOGIC SOFTWAREDRAG AND DROP (D&D) an instruction instead of typing an instruction. This eliminates errors in typing. All the instructions are displayed ON-SCREEN during Design time. Each and every element is directly addressed with their NAMES not by numbers or codes, which are very difficult to remember. Ex: At design time, you call a SWITCH#0 in your Ladder program by D&D the component called SWITCH#0, and that’s it, not by typing a few digits numbers or codes.Appropriate LIST boxes (input, output) open as you D&D an instruction in LADDER WORKSPACE.Ladder workspace is 24X100 instruction CELLs are available for your use.TOOL TIP features are available at the end of each instruction prompting you “what to do next”Very user friendly.Extensive ON-LINE HELP menu available.GUI based STATUS of the entire PLC is displayed during RUN TIME.Programs are saved, retrieved, edited by simply clicking on Menu list box.Extensive EDIT features are available. 55 Power Electronics Development TrainerSize of Breadboard : 172.5 mm × 128.5mmDC Power Supply :+5 V, -5 V 500 mA,+12V, -12 V 500 mA+15 V, 250 mA+35V, -35V, 250 mAAC Power Supply :18V-0V-18V ,0V-15VOn board Firing CircuitsFrequency range : 30Hz to 900Hz variableAmplitude : 12VPWM control of G1, G2, G3 and G4Duty cycle control of “Gate”Signal is 0 to 100%SCR Assembly : 4 SCRs 2P4M, 400V/2APower Devices : IGBT-G4BC20S, MOSFETIRFZ44N,UJT-2N2646, DIACDB3,TRIAC-BT136, PUT-2N6027Circuit Components on board : Electrolytic Capacitor 10µF, 63V,Electrolytic Capacitor 1µF, 63V ,Met. Capacitor 0.33µF, 63V ,Diode 1N4007, Inductor 220uH, 4.7µH, 10mH.Pulse transformer on board :2 nos. PT4502 1:1 and one is PT4503 1:1:1Load selector : 6 load resistances- 47E/7W,1K/1W, 1K/10W, 10K/10W,120E/5W, 2K2/2W.Test points : 10 nos (Gold plated)Power Supply (Mains) : 220V/110V, 50Hz/60HzIncluded Accessories :Bread boards : 2 nos.Connecting wires : 20 nos.2mm to 1mm Patch cords : 15 nos.2mm Patch cords (Red) 16” : 4 nos.2mm Patch cords (Black)16’’ : 4 nos.2mm Patch cords (Blue) 16’’ : 12 nos.Mains cord : 1 no.with i) Power Semiconductor Application Experiment Panel ii)CON / INV Panel iii)Triggering circuit / dv/dt Protection panel 56 ELECTRICAL & ELECTRONICS MEASUREMENT LAB (6TH SEM) 57 Digital LCR meterVariable measured- L,C,R and loss angle (D factor ) Measured frequencies: 1 KHz, 100KHzDisplay: 3⅟₂ digit , Resistance: 0 to 20 MΩ, 0.1 Ω , Capacitance: 0 to 20000μF, 0.1 pF Inductance: 0 to 20000 H, 0.1μH ,D factor: 0.01 to 8.0 with 1% error 58 Distortion Factor MeterFrequency : 20 Hz to 200KHz Distortion:0.1% to 100% f.s.d. in steps ,Input sensitivity: 100mV (r.m.s.), Input impedance: 1MΩ/160pF, Voltmeter range: 300μv to 300v f.s.d. in 13 range 59 To measure L & Q by Maxwell methodFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 60 To measure the unknown capacitance by Schering bridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 61 To measure the unknown frequency by Wein BridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER WITH FREQ. COUNTER & CRO SIG. O/P INBUILT& CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., BACKLIGHT LED & WOODEN HARD BOX 62 MICROCONTROLLER AND EMBEDDED LAB (5TH SEM) 63 Microcontroller Trainer Kit 1.Write a Simple Assembly Programs fora. Addition b. Subtraction b. Multiplication d. Division2. Write a Programs for (any two of the following)i. 4 x 4 Matrix Keypad Interfaceii. character based LCD Interfaceiii. Analog to Digital Conversion (On chip ADC)iv. Serial EEPROMv. Seven Segment LED Display Interfacevi. Interfacing With Temperature Sensorvii. Stepper Motor Interface8 BIT EMBEDDED MICROCONTROLLER TRAINERFEATURES•Single board design with various resources•Excellent training platform for embedded applications•Software development tools include assembler and ‘C’ compiler•Easy adaptability to different versions of microcontroller in the same family SPECIFICATIONS•Experimental board for 40 pin MCS51 and AVR family of microcontrollers•In-system programming (ISP) facility for many microcontrollers•Double RESET signal with manual key•Crystal frequency: 11.0592MHz•On-board RS232 compatible serial interface terminated in a 9 Pin D female connector•4×4 matrix keyboard•16×2 alphanumeric LCD connector (4-bit interface) and trimmer for contrast adjustment•Four 7-segment LED displays•I2C EEPROM (24Cxx)•Real time clock (DS1307) with lithium battery and SRAM•8-high current output port (500mA) for driving external loads•Two 12V sugar cube relays•Continuous tone piezo buzzer•Temperature sensor socket with thermostat functions•Four 8-bit A/D converter, one 8-bit D/A converter provided by PCF8591•All port-pins available on 10-pin box header•8 LEDs for easy logic state monitoring•8 input trigger switches using 8 push buttons•ISP programming with Flash ISP for AT89S51/52/8252/AVR•Infrared remote control receiver module IC supported•P89V51RD2BN•AT89S52 Installable software on CD•Programmers notepad : Free, open source, text editor•Flash ISP programmer software for 89SXX•Bascom basic compiler (demo version)•MIDE-51: An IDE for MCS-51 microcontroller•WinAVR : open source C compiler for AVR•Sample programs for peripherals DC 12V/500mA output power supplyEXPERIMENTS• Study of LED blink• Study of dancing light• Study of LCD display• Study of LCD-keyboard display• Study of 7 –segment display• Study of RC5 remote control test program• Study of analog to digital converter• Study of real time clock (RTC) 64 ADVANCE COMMUNICATION ENGINEERING LAB 65 To be familiar with the following network components:THIS WILL BE A FULL PACKAGE OF THE FOLLOWINGS:-** RJ5/CAT5CABLES 100 METERSRJ 45CONNECTORS 100 PCSCUTTER & CRIMPING TOOLS FOR RJ45/CAT-5CABLESCABLE TESTER/TRACKER…….. 4 PCSHUBS WITH ACCESSORIES & TOOL KIT NETWORK INTERFACE DIFFERENT CARD 66 COMPUTER NETWORK LAB 67 Network ComponentsCAT 5/5E/6 cable :100mtrs (Rs 2000/-), RJ 45 Connectors: 200pcs (Rs. 500/- )RJ 45 Crimping Tools: 05(Rs. 800/- each)LAN Cable Tester (RJ 45): 05 (Rs 1000/- each) 68 24 Port managed switchNo. of Ports: 10/100 Mbps 24 Ethernet ports, Switch Fabric: 32 Gbps, Form Factor: Rack Mountable,OS: LAN base Image, Console port: Availavble for configuration, Mac Address table: 4000 or higher, VLAN: Supported, MTU: 9100 with support for jumbo frames, Warranty: 3 years onsite comprehensive warranty including parts and labor plus onsite technical support with 24x7 69 24 Port Unmanaged switch24-port 10/100/1000Mbps Ethernet switch Wifi Router: 300 Mbps wireless router with 4 LAN ports and 1 WAN port 70 8 port HubExternal Power Supply, 8 Nos RJ-45 connectors for 10BASE-T/100BASE-TX,Ethernet Ports 8-Port, Capacity 1.6 Gbps, Wireless Speed 10 / 100 Mbps 71 Access points54 Mbps Access point for wifi network: No.of Channel: Dual channel for support upto 108 Mbps ( 2x54Mbps), Backbone connectivity: connect over Fast Ethernet through backbone switches, Security: Security enabled Wifi connectivity with option for Broadcast of SSID,Network:802.11 a/b/g/n network support, PoE: PoE enabled, Form factor: Wall or ceilling mountable with physical lock suppor. Warranty and support: 3 years on site comprehensive warranty including parts and labour plus on site technical support with 24 X 7 72 LAN TrainerEthernet (IEEE 802.3 wireless LAN (802.11),Token bus ( 802.4) Token ring ( 802.5), Data rate : 10/100 Mbps for ethernet, 1, 2, 5.5, 11 Mbps for wirless & LAN as per IEEE 802.11b, connectivity through RJ 45 connector. 73 Installation & commissioning of network(i) Laying ofOFC & CAT 6 Cable (ii) splicing (iii) Installation & network testing 74 INSTRUMENTATION AND CONTROL LAB (6th sem) 75 To measure displacement with LVDT ACTUAL LVDT WITHINSTRUMENTATION AMPLIFIERDC O/P WITH DIGITAL METER, 3and 1/2 digit LED display with polarity indicator, sensitivity of 10mV/mm in the range of 10mm. 76 To measure temperature with thermocoupleTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 77 To measure temperature with thermistorTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 78 To measure pressure with strain gauge STRAIN GAUGE SENSOR WITH WAIGHT LOADING SYSYTEM SAMPLE WEIGHTS.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR 79 To plot the Characteristics of RTD (PT-100)RTD 3 WAIR SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 80 Temperature controller with on-off controller, Temperature controller with PI controller, Temperature controller with PID controllerTemperature controller with facilities for P, I, D and relay control blocks, Operating temperature: Ambient to 90°C, Separate controls for P, I, D channel gains,Two settings for relay hysteresis, Fast 25W oven fitted with IC temperature sensor, Forced cooling option to ready oven for next experiment, Digital display of set and measured temperature on a 3½ digit built-in DVM, 0-9999 sec, timer on panel for a convenient temperature response experiment, Buffered output for recorder 81 CIRCUIT THEORY LAB 82 Determine the permeability of magnetic material by plotting its B-H curveHysteresis Loop Tracer/ BH Curve apparatus220volt AC, 50Hz supply 83 Series parallel resonance of R-L-C cktKit for Series parallel resonance of R-L-C ckt: The Set-up consist of Power supply (with variable frequency), audio oscillator with digital readout, digital RMS meters and different number of inductors (smoothly variable), capacitors, Rheostat, patch cord & manual. 84 SWITCH GEAR LAB 85 Speed control of Induction motor 1ph by using SCR3Φ, 400V ac, 50HZ.,1HP, 1440 rpm. Speed control using ac back to back configuration of SCRs and to note Speed vs. Load Characteristics at open loop condition. This unit should consist of AC 3Φ Induction Motor (1HP) coupled with a (i) DC Shunt Generator (1HP) for loading and (ii) a DC Tachogenerator to be used for speed feedback control. A DC meter must be provided for displaying the speed of the motor from the Tachogenerator with suitable AC Ammeter and Voltmeter for the measurement (AE Make Panel Type or digital) Sheet Metal enclosure with powder coating paint must be provided. (with foundation & Experiment Table) 86 C.T. & P.T. testing trainer kit C.T. & P.T.testing trainer kit - Variable AC voltage source (0-220V)& variable AC current source (0-25A), CT for 25/5A, PT for 220/110V, Autotransformer for voltage & current adjustment, MCB protection, To determine Ratio error, Phase angle error of CT & PT, with Burden box. , polarity check indicator , range selector switch. 87 Induction type electromagnetic relay* Over Current (IDMTL Electro- Mechanical Type , Model CDG-11 or equivalent) Relay,*PSM, TSM setting* Auxiliary Relay,* Counter /Timer,* D.W. Transformer, * Variac,* Knife Switch,* DC power supply for DC auxiliary relay and the relay,* Portable Ammeter.Necessary panel for the complete set up with wooden (teak wood) table (4x3x2.5) 88 Air Circuit BreakerCut section model 89 Transmission line protection simulation KitOver Current, Earth Fault, Over Voltage, Under Voltage, Directional, Differential, Distance protection 90 POWER PLANT LAB 91 Diesel generator power plantmodel of small diesel generator power plant 92 Hydro power plantmodel of micro Hydro power plant 93 Horizontal axis small wind turbinemodel 94 CSP plantmodel 95 MEASUREMENT LAB 96 Kelvin double bridgeCompletely self contained, stand alone unit with built in power supply, required meters, Standard Resistance, wooden bench, high sensitivity spot light type galvanometer, connecting patch chords and operating manuals. 97 RENEWABLE ENERGY LAB 98 Renewable Energy Labsolar PV plant- Model 99 Renewable Energy Labvertical axis small wind turbine- Model 100 ELECTRIC MACHINE LAB 101 VoltmeterVoltmeter (M.I type) 0-150V/300V/500V 102 VoltmeterVoltmeter (M.I type) 0-20V/50V 103 AmmeterAmmeter (M.I type) 0-5A/10A/20A 104 AmmeterAmmeter (M.I type) 0-1A/2A/5A 105 MultimeterAnalog Multi-meter of ISI marked: DC : 0-200 mV/ 1000 V & 0- 2mA – 10 A,AC : 0 – 200mV/1000V &0-2 mA – 20 A, Resistance : 0 – 200 Megaohm, with shock proof protection & other facilities and operatingmanuals. 106 MultimeterDigital Multi-meter of ISI marked: DC : 0-200 mV – 1000 V & 0-2mA – 10 A,AC : 0 – 1000 V & 0- 2mA– 20 A, Resistance : 0 – 200 Megaohm, with diodetesting, data hold, shock proof protection , auto power off etcfacilities and operating manuals. 107 WattmeterDynamometer Wattmeterof ISI marked : Low Power Factor ( 0.2 ) : Current Rating : 5/10 A , Voltage Rating : 150/300 / 600 V , with anti-parallax mirror , 120 mm scale length , knife edge pointer, mouldedBakelite body, portable. 108 VoltmeterVoltmeter (PMMC type) 0-150V/300V 109 AmmeterAmmeter (PMMC type) 0-2A/5A 110 StarterDC 3-point Starter : 220 V DC , 15 A 111 StarterDC 4-point Starter : 220 V DC , 15 A 112 DC Power SupplyDC Power Supply : Input : 415V, #-Phase AC, 50 Hz;Output : 220V DC , 5 KW of a standard make . 113 RheostatRheostat with sliding Jockey : 100 Ohm , 5 A 114 RheostatRheostat with sliding Jockey : 500 Ohm , 5 A 115 Digital Energy MeterDigital Energy Meter of ISI marked: Three Phase AC , 440 V , Maximum 30 A, 50 Hz with operatingmanual. 116 Digital MeggerDigital Megger for measuring insulation resistance of ISI marked: 250 / 500 V, Maximum 200 Mega ohmwith operating manual 117 VariacSingle Phase Variac of ISI marked : Input:– 230 V AC, Output : 0 – 270 V AC , 1 KVA, 50 Hzof a standard make 118 VariacThree Phase Variac of ISI marked : Input:– 415 V AC, Output : 0 – 500 V AC , 3 KVA, 50 Hzof a standard make 119 Clamp on MeterClamp on Meter of ISI marked : Digital type : For measuring Voltage ( AC/DC ), Current ( AC/DC ) , resistance, Power & Power Factor with operating manuals 120 Phase Sequence IndicatorPhase Sequence Indicator of ISI marked : 50 – 500 V AC, 25 – 60 Hz 121 Frequency MeterFrequency Meter of ISI marked: Digital Type : 240 V, 47 – 99 Hz 122 TransformerSingle-Phase Transformer : 1 KVA , 230 V/115V , 50 Hz( Air Cooled) 123 TransformerThree-Phase Transformer : 3 KVA , 415/230 V , 50 Hz 124 3-Ph Resistive LoadThree phase resistive load : 400 V , 6 KW 125 3-Ph Inductive LoadThree phase inductive load : 400 V , 3 KW 126 3-Ph Capacitive LoadThree phase capacitive load : 400 V , 3 KW 127 3-Ph StarterStar Delta automatic starter for 3 Phase,400 V, 5 Hpmotor 128 3-Ph DOL StarterDOL & Auto -Transformer Starter : 3-phase AC , 400V, 10A, 50 Hz 129 StroboscopeDigital Stroboscope - 10,000 rpm 130 DCGenerator Voltage build UPSupply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Building up Voltage in DC Generator ( Open Circuit / Saturation Characteristics: DC Shunt Motor of ISI marked : 2HP or 5HP, 220 V. Machines will have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and operating manual isalso must.(with foundation & Experiment Table) 131 Brake test in DC Series Motor Supply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , Spring balance & loadings, protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Brake test in DC Series Motor& load Characteristics: DC Series Motor of ISI marked : 2HP, 220 V.Machineswill have to be set on M.S.Channel base with suitable footing/ fixtures and screws etc. and operatingmanual is also must.(with foundation & Experiment Table) 132 Speed Controlof 3-Phase Squirrel cage Induction motorSupply, Installation , Commissioning & Testing with necessary & suitable ISI marked meters such as ammeter, voltmeter, frequency meter , starter, protective devices and all other accessories mounted on a standing panel board as per following specification :For Speed Controlof 3-Phase Squirrel cage Induction motorby – (i) volt /freq control method : Three phase Squirrel cage induction motor : 2HP, 400V with v/f controller.Machineswill have to be set on M.S.Channel base with suitablefooting/fixturesandscrewsetc.includingtheoperating manual.(with foundation & Experiment Table) 133 Load Test of an Alternator & % regulation at various loads with Unity Power factorSupply, Installation , Commissioning & Testing with suitable ISI marked ammeter, voltmeter, starter, star connected load , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Load Test of an Alternator and Determination of%-age regulation at various loads with unity power factor : DC Shunt Motor of ISI marked : 3HP, 220 V , AlternatorISI marked: 2 KVA, 415 V , 50 Hz.Machineswill have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and andoperating manual is also must.(with foundation & Experiment Table) 134 Measurement of Slip of 3-Phase induction motorSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter, stroboscope etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :Measurement of Slip of 3-Phase induction motor by –(i) Stroboscopic& (ii ) Tachometer methods and reversing the direction of rotation of the motor : Three phase squirrel cage induction motor of ISI marked: 2 HP , 415 V , 50 Hz .Machineswill have to be set on M.S.Channel base withsuitable footing/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 135 Synchronization of two 3-Phase alternatorsSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification : Synchronization of 3-Phase alternator ( 2 SETS ) by– (a) Three Lamp & (b) Synchroscope Methods : DC Shunt Motors of ISI marked : 5HP, 220 V ,Alternators of ISI marked: 3 KVA, 400 V, 50 Hz.Machineswill have to be set on M.S.Channel base withsuitable footings/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 136 POWER SYSTEM LAB 137 KIT FOR STUDY OF ACTIVE & REACTIVE POWERWITH SIMULATIOL KIT & LAPTOPStudy of Active & Reactive power with simulator Kit and Laptop with appropriate software, The kit should consist of variable Inductive & Capacitive load to observe change in active & Reactive power 138 MODEL OF VARIOUS TYPES OF TURBINES USED IN POWER GENERATING STATIONSModel Piece of each type of Turbine 139 PYRANOMETERMEASUREMENT OF SOLAR RADIATION BY PYRANOMETER 140 PHOTO VOLATIC SYSTEM USED IN STREET LIGHTWITH SOLAR PLATE,PV CELL,BATTERY,CHARGER 141 STUDY OF POWER SYSTEM OF 6.6 KV/400 V SUBSTATION USED FOR A HOUSING CONPLEXMODEL 142 D.C NETWORK ANALYSERD.C NETWORK ANALYSER FOR STUDY OF DIFFERENT TYPES OF FAULTS 143 DIFFERENT TYPE OF EXCITATIONS SYSTEM USED IN ALTERNATORSTATIC EXCITER,SHAFT MOUNTED,ROTATNG TYPE EXCITER & Brushless exciter ( Model only) 144 MISCELLANEOUS 145 MOTOR-ALTERNATOR SET FOR SYNCHRONISATION OF TWO ALTERNATOR WITH SYCHRONISING PANEL INCLUDING CHECK SYNCHROSCOPE & BULB ARRANGEMENT TO PERFORM TWO BRIGHT ONE DARK LAMP METHOD1.TWO SET OF D.C MOTOR 2.5 KW,230 VOLT,3000 R.P.M WITH SPEED CONTROL ARRANGEMENT 2. TWO SET OF 1 KVA,3 PHASE,440 VOLT,3000 R.P.M ALTERNATOR WITH BASE MOUNTING & EXCITATION SYSTEM. 146 PlierPlier of good quality 147 TesterTester Screwdriver of reputed brand 148 Screwdriver setScrewdriver set of reputed brand
Contract Date: Mar 12, 2026 Contract Value : 33.87 Lakh
Government Departments No of Bidders 9
West Bengal View Result →
42.
Public Administrative Department #9774375 AOC
Tender For Supply Of Street Light Materials , Street Light Materials , 40 W Tube Light , 40 W Tube Light Starter , 40 W Copper Choke , 40 W Electronic Choke , Tube Light Side Holder , 40W Tubular Fluoresent Super Brigth Lamp , 40W Ballast For Fluoresent Lamp , 40W Planet Electronic Ballase Heavy Duty , 1 X 40 W Street Light Fitting Cover (Cylinder) , 1 X 40 W Street Light Fitting Cover (Square) , 1 X 40 W Street Light Fitting , 1 X 40 W Street Light Fitting Pipe , 1 X 40 W Street Light Fitting Clamp , 1 X 40 W Street Light Fitting Side Holder , 20W Led Street Light Fitting Set , 25W Led Street Light Fitting Set , 30W Led Street Light Fitting Set , 36W Led Street Light Fitting Set , 45W Led Street Light Fitting Set , 50W Led Street Light Fitting Set , 60W Led Street Light Fitting Set , 100W Led Street Light Fitting Set , 150W Led Street Light Fitting Set , 1/18 Pvc Insulated Copper Wire , 3/20 (2.0 Sqmm) Flex Copper Wire , 3/20 Pvc Insulated Vir Copper Wire , 7/16 Pvc Insulated Vir Copper Wire , 7/20 Pvc Insulated Vir Copper Wire , 25W/30W Led Street Light Fitting Board , 2.5 Flex Wire , 1/18 Copper Wire , 3/20 Copper Wire , 7/16 Copper Wire , 7/20 Copper Wire , Hook Up Wire , Insulation Tape , 250 W Sodium Lamp , 250 W Sodium Holder , 250 W S.V Choke , 250 W S.V Ignator , 250 W S.V Capacitor , 250W Sodium Street Light Fitting , 250W Sodium Street Light Cover , 250W Sodium Street Light Gi Pipe , 250W Sodium Street Light Pipe Cover , 150 W Sodium Lamp , 150 W S.V Choke , 150 W S.V Ignator , 150 W S.V Capacitor , 250W Metal Halide Choke , 150W Metal Halide Choke , 150W Metal Halide Lamp , 150W Metal Halide Ignitor , 150W Metal Halide Capacitor , 250W Metal Halide Lamp , 250W Metal Halide Ignitor , 250W Metal Halide Holder , 250W Metal Halide Capacitor , 400W Metal Halide Choke , 400W Metal Halide Lamp , 400W Metal Halide Ignitor , 400W Metal Halide Capacitor , 400W Metal Halide Holder , 40A Isolator , 40A Contactor , 63A 4 Pole Mcb Switch , 63A S/P Mcb Switch , 63A 6 Way Connector , 63A Isolator 4 Pole , Repair Work & Service Charges For Highmast Flood Light Fittings (Per Pole) , 3/20- 2 Core Aluminium Wire , 4 Sq.Mm 3 Core Flat Cable , 2.5 Sq.Mm 3 Core Flat Cable , 1.0 Sq.Mm Multi Standared Flexible Copper Cable , 1.5 Sq.Mm Multi Standared Flexible Copper Cable , 2.5 Sq.Mm Multi Standared Flexible Copper Cable , 4.0 Sq.Mm Multi Standared Flexible Copper Cable , 24X24 Meter Board , 18X18 Meter Board , 12X12 Meter Board , 1/18 Pvc Insulated Vir Aluminium Wire , 3/20 Pvc Insulated Vir Aluminium Wire , 7/20 Pvc Insulated Vir Aluminium Wire , 7/20 Aluminium Wire , 3/20 Aluminium Wire , 70 W Sv Lamp , 70 W Sv Choke , 70 W Sv Holder , 70 W Sv Capacitor , 70 W Sv Ignator , 1X40 W Street Light Fitting Glass , 40 W Street Light Fitting Side Plate , 16 Amps Main Switch , 32 Amps Main Switch , 63 Amps Main Switch , 32 Amps Main Switch (Dp) , 5000 W Street Light Automatic On/Off Timer Switch , Photanic Intellingent Automatic Street Light Controlling Divice Switches Timer / Sensor On/Off Including Fixing All Complete Set , 16 Amps Fuse Carrier , 32 Amps Fuse Carrier , 63 Amps Fuse Carrier , 100 Amps Fuse Carrier , 1X40 W Street Light Fittings Set With Clamp Set (2 Sets), Bolt-Nut, 20Mm Gi, Bend Pipe, 3/20 Wire , 1/40 W Street Light Fittings Set With Heavy Duty Copper Choke, Starter, Tube , Led Street Light Fittings Accessories Clamp Set (2 Sets) 32 Mm Bend Pipe, Bolt-Nut Wire , 25W Led Street Light Fitting Pcb & Drive Including Service Charges , 45W Led Street Light Fitting Pcb & Drive Including Service Charges , 18W Led Lamp , 20W Led Lamp , 23W Led Lamp , 30W Led Lamp , 36W Led Lamp , 40W Led Lamp , 50W Led Lamp , 72W Led Lamp , 100W Led Lamp , 120W Led Lamp , 36W Cfl Lamp , 36W Cfl Choke , 1X36w Cfl Street Light Fitting , 36W Cfl Pipe , 36W Cfl Fitting Clamp , 36W Cfl Light Cover , 25/30 W Led Street Light Fitting Board , 25/30W Led Street Light Fitting Drive , Timer Clock
Contract Date: Mar 06, 2026 Contract Value : 24,751
Local Bodies No of Bidders 2
43.
Housing Urban and Rular Development #9752066 Technical Bid
Tender For Erection of various Electrical/Civil works from contractors/ manufacturer registered with UPRNN.- 1 VARIABLE REFRIGERANT FLOW SYSTEM (OUTDOOR UNITS) ; MAKE : Carrier / Toshiba / Daikin / Samsung / LG / Blue Star / Voltas 2 Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 0C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building) For Cooling or Heating or Both 3 14 HP to 22 HP 4 INDOOR UNIT 5 Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB emperature. (Make will be same as of Outdoor) 6 1.2 TR 7 1.6 TR 8 2.0 TR 9 2.6 TR 10 3.6 TR 11 4.1 TR 12 High wall type Indoor unit 13 Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) 14 2.0 TR 15 Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted mid high static ductable type Indoor unit equipped with washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) High Static Ductable units (minimum 49 to 77 pascal external static pressure) 16 3.2 TR 17 4.6 TR 18 Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted high ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) 19 6.6 TR 20 8.0 TR 21 Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs 22 Indoor Units 23 Outdoor Multi Joint 24 COPPER REFRIGERANT PIPING 25 Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 26 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 27 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 28 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 29 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm 30 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 31 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 32 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 33 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm 34 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 35 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 36 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 37 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm 38 DUCTING, GRILLS,DIFFUSER AND INSULATION 39 Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required. 40 Thickness 0.63 mm sheet 41 Thickness 0.80 mm sheet 42 Thickness 1.00 mm sheet 43 Thickness 1.25 mm sheet 44 Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. 45 Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class O) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 46 Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. 47 100 mm width X 50 mm depth X 1.6 mm thickness 48 300 mm width X 50 mm depth X 1.6 mm thickness 49 600 mm width X 62.5 mm depth X 2.0 mm thickness 50 Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 51 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 52 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 53 Upto 35 sq. mm (clamped with 1mm thick saddle) 54 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 55 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 56 Upto 35 sq. mm (clamped with 1mm thick saddle) 57 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 58 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 59 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 60 4 X 10 sq. mm (25mm) 61 3½ X 120 sq. mm (45mm) 62 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 63 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos Cement sheet 64 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, will be paid in this account).ral frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer in- charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). Overhead informatory road signageomplete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 65 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37x 25 x1.6 mm fixed to ceiling with12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 66 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In- Charge. With cement mortar 1:4 (1 cement : 4 fine sand) 67 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 68 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 69 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture 70 Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar 71 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm 72 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 73 Lime, moorum, building rubbish 74 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. :Internal work - Exposed on wall 75 20 mm nominal outer dia .Pipes. 76 25 mm nominal outer dia .Pipes. 77 32 mm nominal outer dia .Pipes. 78 MR Items 79 VARIABLE REFRIGERANT FLOW SYSTEM (Indoor UNITS) ; MAKE : Carrier / Daikin / Samsung / LG / Blue Star / Toshiba / Voltas 80 Supply installation, testing and Commission of Heat Pump Type variable refrigerant flow modular type air conditioning system suitable for both heating and cooling with hermatically sealed Inverter driven type Scroll Compressors ,with electronic controls & Remote as applicable. The units should be suitable for 415 ±10% V for outdoor unit including fully charged with refrigerant R410A to outdoor unit and all running refrigerant pipe as per detail given in specifications & drawings for the following configurations. It shall include anti vibration isolator pad for outdoors unit.The unit shall deliver the rated capacity at AHRI Conditions and work even at 55°C ambient temperature without tripping. The interconnecting copper pipes of outdoor units should be provided with anti-corrosive coatings and condenser coils with anti corrosive blue fins. The cost of loading, Unloading at site , shifting to locations and interconnecting ODUs joints , shall be included. Rates 81 24 / 26 HP 82 Floor Standind Ductable Type Indoor Unit 83 14.40 TR 84 Supply installation testing and comission of double skin sheet metal sectionalised construction treated fresh air units double skin panels with 46mm thick injected PUF of density not less than 40kg/ cum with thermal break profile The treated fresh air units shall be complete with pre- filter (MERV-8) 300mm thick fine filters IMERV-13) multi row deep DX cooling coil of copper tube and aluminium fin construction (with 100mm gap between two sets of three rows deep cooling coils) forward curved DIDW centrifugal fan belt drive package insulated SS auxiliary drain pan IE-02 squirrel cage induction motor all complete as per the specifications: 85 5000 CFM 86 5500 CFM 87 9000 CFM 88 3000 CFM 89 Supply of TFA Power Panel 90 Wire Less Remote 91 AHU KIT -Supply, Installation, Testing and Commissioning of VRV Kits for AHUs having all controllers & Electonic Expansion Valve (EEV) and temperature set arrangment. It Shall have cut off arrangement after a particular set value of Supply air Temperature. Price should include all control cabling etc. 92 SITC of outdoor type Electrical Panel for Power ON and OFF 415 V with suitable Bus Bars, Lamps, Switches, MFM meter, 93 Incomer: 4P 315 / 400 Amp MCCB 94 Out Going: 4P 32 A / 40 A / 63 A MCB As Required 95 Supply of LT Cable 96 3.5 C X 120 SQ MM AL Cable (Main Panel to VRV/VRF Panel 2 Run Each) 97 4C X 16 SQ MM Cu Cable 98 4C X 10 SQ MM Cu Cable 99 2C X 1.5 SQ MM Shilded Communication Cable 100 Installation Testing and Commissioning 101 Removing of old Out-door units & Installation of newOutdoor Units 102 Removing of All System 103 Core Cutting 100-200 MM 104 Buyback Value 105 Buyback of Removed Material of Existing VRV/VRF out doors, Indoors, Cable Tray, Cables, etc. Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
46.
Health and Family Welfare #9623037 Technical Bid
Tender For supply of stationery- Forms And Register , White Paper(Full Scrape) , Duplicating Paper Gastetner Brand Of 500 Sheets , D.F.C. Paper (Tiger Brand) , File Cover 4 (Four) Fold Ambassador Brand , File Cover With Board 35X25cm (Neelgagan Board File No. 31). , Arch File (World One) , Plastic File Carrier (Folder) , A) Bound Register -No. 40 (Tiger) , B) Bound Register -No. 30 (Tiger) , C) Bound Register -No. 20 (Tiger) , D) Bound Register -No. 10 (Tiger) , A) Rexin Binding Register No.10 (Oxford) , B) Rexin Binding Register No.20 (Oxford) , C) Rexin Binding Register No.30 (Oxford) , D) Rexin Binding Register No.40 (Oxford) , E) Rexin Binding Register No.50 (Oxford) , Cash Book (Oxford) No. 20 (400 Pages Containing) , Twine Thread-White , Log Book No. 10 (Best Quality) , High Lighter Pen (Kores Brand) Red/Yellow/Green/Pink , T-Pins (Oddy) T- Bar Head, Sharp Point Lower Weight, More Pieces , Paper Pin (Box) King Brand , Stamp Pad (Size. 159Mm X 95Mm) Faber Castell , Stamp Pad (Size. 11.6 Cm X 6.5Cm) Faber Castell , Paper Clip (Plastic-Big Size) (Kores / Bell Brand) , Paper Weight (Glass) (Round/Oval) , Envelop 9X4 (Brown) (Taj Mahal) (Pkt. Of 25 Nos.) , Envelop 12X4 (Brown) (Taj Mahal) (Pkt. Of 25 Nos.) , Envelop 16X12(Plastic Coated Inside) (Pkt. Of 25 Nos.) , Envelop 12X6 (Plastic Coated Inside) (Pkt. Of 25 Nos.) , Envelop 12X18 (Plastic Coated Inside) (Pkt. Of 25 Nos.) , Envelop 12X10 (Plastic Coated Inside) (Pkt. Of 25 Nos.) , Envelop 12X18 (Cloth Coated Inside) (Pkt. Of 25 Nos.) , Envelop 9X 4 (White) (Pkt. Of 25 Nos.) (Pkt. Of 25 Nos.) , Red & Blue Pencil (Camlin / Natraj) , Tag Cotton (Best Quality) (Bundle Contain 1000) L-9 , Correcting Fluid & Diluter (White) (Kores Brand) (Pen Type) , Notice Board Pin (Best Quality) , Chalk Pencil Taj Brand (White) (For Mica Board) , Gum Tube (Camlin Brand) 100 Ml , Glue Stick (Camlin) 8 Gram , Fevicol Mr- Art & Craft Adhesive (100 Ml) , Paper Clips, Gem Clips, U Clips (30 Mm) Multicolored For Office (Bell Brand) , Steel Paper Holding Binder Clips 19Mm , Color Page Marker (Pack 0F 5 Colors) (Camlin) , Ink For Stamp Pad (20 Ml) Kores Brand , Electronic Calling Bell (Havells) , Staple Machine No. 10 (Kangaro) , Staple Machine No. Hs-45P (Kangaro) , Peon-Book- (Oxford) No. 4 , Staple Machine Pin No. 10 (Kangaroo) , Staple Machine Pin No. 24/6 (Kangaroo) , Waste Paper Basket-Plastic (Big Size) , Lock & Key 40 Mm (Godrej / Navtal) , Lock & Key 65 Mm (Godrej / Navtal) , Battery Eveready / Nippo Big Size , Battery Eveready / Nippo Medium Size , Battery Eveready / Nippo Size Aa , Battery Eveready / Nippo Size Aaa , Glucometer Battery , Laryngoscope Bulb , Cotton Thread , White & Coloured , Rexin (Decorated/Plain) , Eraser For Pen & Pencil (Camlin / Nataraj) , Oil Cloth- Best Quality , Colin Glass Cleaner (500 Ml) , Carbon Paper Single Size (Camlin / Kores Brand) , Lifebouy Soap-68 Grm. , Detol Soap - 45 Gm , Indigo- Robin Blue (450 Grm. Pkt.) , Detergent Powder 1 Kg (Tide) , Vim Bar (85Gm) , Sewing Machine Needle (All Size) , Sewing Machine Oil (Usha / Singer) , Sewing Machine Oil (Usha / Singer) , Drawing Pin- 100 Nos. Pkt. (Kores / Camlin Brand) , Rubber Slipper - Bata Size No. 6 , Rubber Slipper - Bata Size No. 7 , Rubber Slipper - Bata Size No. 8 , Rubber Slipper - Bata Size No. 9 , Rubber Slipper - Bata Size No. 10 , Soap Case Plastic (Best Quality) , Razor Blade - 5 Pcs. Pkt (Wilkinson / Topaz) , Washing Soap Ok/Jk/Gk 150Gm , Washing Soda , Ball Pen (Cello/ Mitsubishi) , Century Paper ( White / Red / Pink/ Yellow) , Clip Board - Plastic , Punching Machine - 1 Hole (Kangaro) , Punching Machine - 2 Hole (Kangaro) , Black Board Duster , Torch Light (Led Type) - 3 Cell (Eveready/ Nippo) , Gum Boot - Bata No. 5 , Gum Boot - Bata No. 6 , Gum Boot - Bata No. 7 , Gum Boot - Bata No.8 , Gum Boot - Bata No. 9 , Gum Boot - Bata No. 10 , White Board Marker (Luxor) , Xerox Paper (J. K. Brand) (75 Gsm) , Xerox Paper (J. K. Brand) (75 Gsmsize - A4 , Xerox Paper (J. K. Brand) (75 Gsmfull Scape (Legal) , Xerox Paper (J. K. Brand) (75 Gsmdouble Full Scape , Scale 30 Cm (Apsara) , Pencil (Apsara) , Pen (Blue?Black?Red) Maxwriter , Pencil Sharpner (Natraj) , Pencil Eraser (Natraj) , Scissor (Zebra) Medium Size , Scissor (Zebra) Big Size , Scissor (Metal) Medium Size , Scissor (Metal) Medium Size , Pedal Type Dustbin , Pedal Type Dustbin Small , Pedal Type Dustbin Medium , Pedal Type Dustbin Big , Tissue Paper Roll , Paper Marker Pen (Red/ Green/ Yellow) (Luxor) , Cd Marker Pen (Red/ Green/ Blue/ Black ) (Luxor) , Marker Pen (Big) (Red/ Green/ Blue/ Black ) (Luxor) , Brown Tap Roll (2) - 50 Mtr. (Wonder) , Room Freshener 300 Ml (Best Quality) , Room Freshener Automatic (Kent Type) , Tissue Paper Roll , Door Mat (Best Quality) Size 4 X 2 , Door Mat (Best Quality) Size 1 ½ X 3 , Door Mate With Stick (Grass Type) (Green/Black) 3.5X1.9 , Door Mate With Stick (Grass Type) (Green/Black) 3X1.9 , Door Mate With Stick (Grass Type) (Green/Black) 2.5X1.9 , Wall Clock Quartz Ajanta , Calculator - 12 Digit Casio , Cartridge Paper (Green) Kores Brand , High Light Pen Green / Red / Yellow , Hand Wash (Detol) 225 Ml , White Board A. 2X1.5 B. 4X3 , White Board Duster , Rain Coat (Best Quality) S , Rain Coat (Best Quality) M , Rain Coat (Best Quality) L , Rain Coat (Best Quality) Xl , Rain Coat (Best Quality) Xxl , Doner Refreshment Containing Juice (200 Ml), Water Bottle 500 Ml, Small Size Biscuit Packet , Bar Code Ribbon , Bar Code Sticker Label - (Pack Of 100000 Stickers) , Bar Code Scanner , Smps (Normal) , Smps (Small) , Power Adaptor Laptop , Lan Card , Wireless Access Card , Switch 8 Port (Gigabyte) , Switch 16 Port (Gigabyte) , Switch 24 Port (Gigabyte) , L 3 Switch 24 Port Cisco (Gigabyte) , Climping Tools (D. Link) , Media Convertor (Gigabyte) Optic To Lan (Make & Model Tp Link Ms5210cs & M220l) , Sc & Lc Patch Cord , Poe (For Wireless Routers) , Cat 6 Cable (Lan Cable) D-Link (Per Coil Contain 305 Mtr.) , Optical Fibre Cable 6 Core , Optical Fibre Cable 12 Core , Cat 6 Cable (Lan Cable) D-Link , Rj-45 Connector , Rj-45 Connector , Printer Assosories , 1. Taflon For Hp Laserjet (P1108, M1136 Mfp) , 2. Taflon For Hp Canon (Canon 2900B) , 3. Presure Roller For Hp And Canon Printer (Hp 1108, M1136 Mfp & Canon Lbp2900b) , 1. Motherboard Intel Chipset 945 , 2. Motherboard Intel Chipset G31 , 3. Motherboard Intel Chipset 41 , 4. Motherboard Intel Chipset H61 , 5. Motherboard Intel Chipset H81 , 5. Motherboard Intel Chipset 310 , 1. Ssd 512 Gb , 2. Hdd 1 Tb , 3. Hdd 1 Tb , Ram Ddr Iii 4 Gb , Ram Ddr Iii 8 Gb , Ram Ddr Iv 8 Gb , 1. Power Cable , 2. Usb Cable , 3. Hdmi Cable , 4. Vga Cable , 5. Monitor 18.5 , 6. Monitor 21 , 7. Monitor 32 , 8. Monitor 32(Curve) , 9. Keyboard (Logitech) , 10. Mouse (Logitech) , 11. Ups Battery (Exide) 7 Annual Periodical Maintenance , 12. Air Blower , 13. Screw Driver Set , Water Purifier (Aquaguard) 6 Ltr. Capacity (The Aquaguard Delight Nxt Lite Ro+Mc Water Purifier) , Poe (Power Over Ethernet) For Acess Point , Tonner Chemical Powder (Prodot) 88A , Tonner Chemical Powder (Prodot) 12 A , Tonner Drum (Prodot) 88A , Tonner Drum (Prodot) 12 A , Computer Continuing Paper (Lotus) (10X12) (Pkt. Of 1000 Sheets) , Printer Ribbon For Dot Matrix Printer (Prodot) , Ups (600W-220-240V) Frontech , Pen Drive 64 Gb (Sony) , Smps (Frontech/Intex/Umax) , Hard Disk Ssd (Internal) 500 Gb (Laptop) , Hard Disk Ssd (Internal) 1 Tb (Laptop) , Hard Disk Ssd (External) 500 Gb , Hard Disk Ssd (External) 1 Tb , Scanner (Hp Scanjet 200 Flatbed) Make:Hp , Dot-Matrix Printer (Tvs Msp 240 Printer 9 Pin) , Printer Head (Tvs Msp 240 Printer 9 Pin) , Printer (Colour) Model No. L130 (Epson) , Printer Cum Scanner Model No. L3110 (Epson) , Laserjet Printer Hp P1108 , Laserjet Printer Hp Mfp (1188A) , Laserjet Printer Cannon (Lbp2900b) , Printing Tonner Dismat 12A Competitive Black , Printing Tonner Dismat 88A Competitive Black , Printing Tonner Dismat 36A Competitive Black , Toner For Xerox Machine , A. Cannon 2420L , B. Canon Image Runner-2206 , C. Kilburn Km 1635 (Kyocera) , D. Bizhub 206 (Konmica Minolta) , Printer Cartridge , Hp Ink Jet 802 (Black) Big (Original) , Hp Ink Jet 802 (Color) Big (Oroginal) , Hp Ink Jet 802 (Black) Small (Original) , Hp Ink Jet 802 (Color) Small (Original) , Hp Ink Jet 803 (Black) Big (Original) , Hp Ink Jet 803 (Color) Big (Oroginal) , Hp Ink Jet 803 (Black) Small (Original) , Hp Ink Jet 803 (Color) Small (Original) , Hp Ink Jet 21 (Black) (Original) , Hp Ink Jet 22 (Color) (Original) , Hp Ink Jet 27 (Black) (Original) , Hp Ink Jet 28 (Color) (Original) , Hp Laserjet P-1106 (Original) , Hp Laserjet P-1108 (Original) , Hp Laserjet 1020 (Original) , Hp Laserjer -4100 (Original) , Laserjet Printer Cartridge- 12 A , Laserjer Printer Cartridge -88A , Hp Laserjet-P1505 (Original) , Hp Laserjet M1136 Msp (Original) , Cannon Lbp-2900 (Original) , Cannon Lbp-3000 (Original) , 12A Cnnon-1200 (Original) , Cannon 103-303 (Original) , Cannon Mf13010(C) (Original) , Laserjet Printer Cartridge Model No: Hp 110A , Laser Printer Cartridge Model No: Mfp 1188A , Laser Printer Cartridge Model No: 108A , Laser Printer Cartridge Model No: 108A , Ink Cartridge Hp 678 (Black) , Ink Cartridge Hp 678 (Colour) , Epson Ink For Tank Printer L130 , Epson Ink For Tank Printer L3110 , Printer Cartridge Hp - Gt51 (Black) , Printer Cartridge Hp - Gt52 (Color) (Yellow/Blue/Maganta) , Blank Disc 700 Mb (50 Cd) Moserbeer/Sony , Ssd Hard Drive 512 Gb (Frontech) , Ssd Hard Drive 1 Tb (Frontech) , Monitor 27 Inch (Frontech) , Central Processing Unit (Hp/Lenovo) Specification: Intel Core I3-11Th Gen Or Above, 8Gb Ram Ddr3, 512 Tb Hard Drive, Windows 10 Professional Original , Multifuction Lan Adaptor (Usb To Lan) , Usb Wi-Fi Receiver (Wireless Network Card Adaptor) , Webcam (Logitech) , Compressor For 1 Ton Split Ac (L.G) , Compressor For 1 Ton Split Ac Samsung , Compressor For 1 Ton Split Ac Voltas , Compressor For 1.5 Ton Split Ac (L.G) , Compressor For 2 Ton Split Ac Samsung , Compressor For 2 Ton Split Ac Voltas , Compressor For 2 Ton Split Ac (L.G) , Compressor For 2 Ton Split Ac Samsung , Compressor For 2 Ton Split Ac Voltas , Fan Motor 1 Ton Split Ac (Indoor) , Fan Motor 1.5 Ton Split Ac (Indoor) , Fan Motor 2 Ton Split Ac (Indoor) , Fan Motor 1 Ton Split Ac (Outdoor) , Fan Motor 1.5 Ton Split Ac (Outdoor) , Fan Motor 2 Ton Split Ac (Outdoor) , Copper Pipe With Insulation For Split Ac ¼ , Copper Pipe With Insulation For Split Ac ½ , Copper Pipe With Insulation For Split Ac 3/8 , Copper Pipe With Insulation For Split Ac 5/8 , Capacitor For Split Ac , Capacitor For Split Ac 55/60 Mfd , Capacitor For Split Ac 50+2 Mfd , Capacitor For Split Ac 50+6 Mfd , Capacitor For Split Ac 45 Mfd , Capacitor For Split Ac 30+2 Mfd , Capacitor For Split Ac 30 Mfd , Capacitor For Split Ac 36 Mfd , Capacitor For Split Ac 40+4 Mfd. , Pcb For 1 Ton Split Ac , Pcb For 1.5 Ton Split Ac , Pcb For 2 Ton Split Ac , Pcb (Universal) , Drier For Refrigerator , Drier For Air Conditioner , Drain Pipe For Air Conditioner , Fan Motor For Window Ac 1 Ton , Fan Motor For Window Ac 1.5 Ton , Fan Motor For Window Ac 2 Ton , Compressor For Window Ac 1 Ton , Compressor For Window Ac 1.5 Ton , Compressor For Window Ac 2 Ton , Selector Switch Set For Window Ac Standard , Refrigerant Cylinder With Refrigerant For R 22 (2 Kg Capacity) , Refrigerant Cylinder With Refrigerant For R 22 (5 Kg Capacity ) , Refrigerant Cylinder With Refrigerant For R 22 (10 Kg Capacity ) , Refrigerant Cylinder With Refrigerant For R 32 (2 Kg Capacity) , Refrigerant Cylinder With Refrigerant For R 32 (5 Kg Capacity ) , Refrigerant Cylinder With Refrigerant For R 32 (10 Kg Capacity ) , Refrigerant , Refrigerant R 22 , Refrigerant R 32 , Refrigerant 134-A , Refrigerant R 410 , Adoptor (16/5 To ¼) , Refrigerant Cylinder With Refrigerant For R 410 (2 Kg Capacity) , Refrigerant Cylinder With Refrigerant For R 410 (5 Kg Capacity ) , Refrigerant Cylinder With Refrigerant For R 410 (10 Kg Capacity ) , Refrigerant Hydro Carbon , Butane , Bazing Rod Standard Size , Antimoist (Pkt 5 Pcs) , Antimoist , Compressor For Refrigerator , Compressor For Refrigerator ¼ Hp , Compressor For Refrigerator ½ Hp , Compressor For Refrigerator 1/6 Hp , Compressor For Refrigerator 1/8 Hp , Thermostat For Refrigerator , Thermostat For Window Ac , Box Relay , Box Relay Split Ac , Box Relay Window Ac , Relay + Olp Set For Refrigerator , Relay + Olp Set For Refrigerator ¼ Hp , Relay + Olp Set For Refrigerator ½ Hp , Relay + Olp Set For Refrigerator 1/6 Hp , Relay + Olp Set For Refrigerator 1/8 Hp , Fan Motor For Refrigerator (Frost Free) , Defrost Heater For Refrigerator , Bimetal Thermostat For Refrigerator , Thermal Fuse For Refrigerator , Pcb For Refrigerator , Condenser For Refrigerator , Condenser For Refrigerator 175 Litrs , Condenser For Refrigerator 210 Ltrs , Condenser For Refrigerator 260 Ltrs , Condenser For Refrigerator 310 Ltrs , Evaporator Chamber 175 Litrs , Evaporator Chamber 210 Ltrs , Evaporator Chamber 260 Ltrs , Evaporator Chamber 310 Ltrs , Deforst Timer For Refrigerator , Capilary Tube (Expansion Valve) , Fly Nut ¼ , Fly Nut 3/8 , Fly Nut ½ , Fly Nut 5/8 , Union 3/16 , Union ¼ , Union 3/8 , Union ½ , Union 5/8 , Connector (40-60 A) , Connector (40-60 A)Double Pole , Connector (40-60 A)Single Pole , Thermostatic Expansion Valve R 134A, Coolar, 20C-80C , Desktop Computer: Intel Core I3-13Th Gen Or Above, 8Gb Ram, 5.12 Gb Hard Drive, 18.5 Led Monitor, Windows 10 Professional Original, Keyboard And Optical Mouse, Lan, Ups (Make: Hp) , Desktop Computer: Intel Core I3-13Th Gen Or Above, 8Gb Ram, 5.12 Gb Hard Drive, 18.5 Led Monitor, Windows 10 Professional Original, Keyboard And Optical Mouse, Lan, Ups (Make: Lenovo) , Laptop 15.6 : Intel Core I3-13Th Gen Or Above, 16Gb Ram, 5.12 Gb Hard Drive (Ssd), Windows 10 Professional Original (Make: Lenovo) , Laptop 15.6 : Intel Core I3-13Th Gen Or Above, 16Gb Ram, 5.12 Gb Hard Drive (Ssd), Windows 10 Professional Original (Make: Lenovo) , Split Air Conditioner 1 (One) Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Star Rating) (Make: Samsung) , Split Air Conditioner 1 (One) Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Star Rating) (Make: Voltas) , Split Air Conditioner 1.5 Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Star Rating) (Samsung) , Split Air Conditioner 1.5 Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Star Rating) (Voltas) , Split Air Conditioner 2 Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Stars Rating) (Samsung) , Split Air Conditioner 2 Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Stars Rating) Voltas , 183 Ltrs Refrigerator Single Door Rating 4 (Four) Stars Including 1 (One) Year Warranty (Samsung) , 198 Ltrs Refrigerator Single Door Rating 4 (Four) Stars Including 1 (One) Year Warranty (Samsung) , 223 Ltrs. Refrigerator Single Door Rating 4 (Four) Stars Including 1 (One) Year Warranty (Samsung) , 236 Ltr. Refrigerator Double Door Rating 4 (Four) Stars Including 1 (One) Year Warranty Samsung , 256 Ltr. Refrigerator Double Door Rating 4 (Four) Stars Including 1 (One) Year Warranty Samsung , 8 Kg Semi Automatic Washing Machine (Samsung) , 10 Kg Semi Automatic Washing Machine (Samsung) , 11 Kg Semi Automatic Washing Machine (Samsung) , 14 Kg Semi Automatic Washing Machine (Samsung) , 7.5 Kg Washing Machine (Semi Automatic) Samsung , 10 Kg Washing Machine (Semi Automatic) Samsung , 11 Kg Washing Machine (Semi Automatic) Samsung , Digital Bio Matrix Attendance Machine (Minimum 500 Fingerprints Capacity) , Battery For Online Ups Make: Exide Smf Capacity: 12Volt/ 17 Ah , Battery (80Ah) Amaron , Battery (80Ah) Exide , Battery (80Ah) Powerzone , Battery (65 Ah) Amaron , Battery (65 Ah) Exide , Battery (65 Ah) Powerzone , Battery (15 Amp) Amaron , Battery (150 Amp) Exide , Battery (150 Amp) Powerzone , Battery (180 Amp) Amaron , Battery (180 Amp) Exide , Battery (180 Amp) Powerzone , Battery (100 Amp) Amaron , Battery (100 Amp) Exide , Battery (100 Amp) Powerzone , 1 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable , 2 Kva Online Ups 3 Phase ( Back , 3 Kva Online Ups 3 Phase ( Back , 5 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable , 10 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable , 20 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable , 30 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable , Non-Schedule Forms And Register , White Paper(Full Scrape) , Duplicating Paper Gastetner Brand Of 500 Sheets , D.F.C. Paper (Tiger Brand) , File Cover 4 (Four) Fold Ambassador Brand , File Cover With Board 35X25cm (Neelgagan Board File No. 31). , Arch File (World One) , Plastic File Carrier (Folder) , A) Bound Register -No. 40 (Tiger) , B) Bound Register -No. 30 (Tiger) , C) Bound Register -No. 20 (Tiger) , D) Bound Register -No. 10 (Tiger) , A) Rexin Binding Register No.10 (Oxford) , B) Rexin Binding Register No.20 (Oxford) , C) Rexin Binding Register No.30 (Oxford) , D) Rexin Binding Register No.40 (Oxford) , E) Rexin Binding Register No.50 (Oxford) , Cash Book (Oxford) No. 20 (400 Pages Containing) , Twine Thread-White , Log Book No. 10 (Best Quality) , High Lighter Pen (Kores Brand) Red/Yellow/Green/Pink , T-Pins (Oddy) T- Bar Head, Sharp Point Lower Weight, More Pieces , Paper Pin (Box) King Brand , Stamp Pad (Size. 159Mm X 95Mm) Faber Castell , Stamp Pad (Size. 11.6 Cm X 6.5Cm) Faber Castell , Paper Clip (Plastic-Big Size) (Kores / Bell Brand) , Paper Weight (Glass) (Round/Oval) , Envelop 9X4 (Brown) (Taj Mahal) (Pkt. Of 25 Nos.) , Envelop 12X4 (Brown) (Taj Mahal) (Pkt. Of 25 Nos.) , Envelop 16X12(Plastic Coated Inside) (Pkt. Of 25 Nos.) , Envelop 12X6 (Plastic Coated Inside) (Pkt. Of 25 Nos.) , Envelop 12X18 (Plastic Coated Inside) (Pkt. Of 25 Nos.) , Envelop 12X10 (Plastic Coated Inside) (Pkt. Of 25 Nos.) , Envelop 12X18 (Cloth Coated Inside) (Pkt. Of 25 Nos.) , Envelop 9X 4 (White) (Pkt. Of 25 Nos.) (Pkt. Of 25 Nos.) , Red & Blue Pencil (Camlin / Natraj) , Tag Cotton (Best Quality) (Bundle Contain 1000) L-9 , Correcting Fluid & Diluter (White) (Kores Brand) (Pen Type) , Notice Board Pin (Best Quality) , Chalk Pencil Taj Brand (White) (For Mica Board) , Gum Tube (Camlin Brand) 100 Ml , Glue Stick (Camlin) 8 Gram , Fevicol Mr- Art & Craft Adhesive (100 Ml) , Paper Clips, Gem Clips, U Clips (30 Mm) Multicolored For Office (Bell Brand) , Steel Paper Holding Binder Clips 19Mm , Color Page Marker (Pack 0F 5 Colors) (Camlin) , Ink For Stamp Pad (20 Ml) Kores Brand , Electronic Calling Bell (Havells) , Staple Machine No. 10 (Kangaro) , Staple Machine No. Hs-45P (Kangaro) , Peon-Book- (Oxford) No. 4 , Staple Machine Pin No. 10 (Kangaroo) , Staple Machine Pin No. 24/6 (Kangaroo) , Waste Paper Basket-Plastic (Big Size) , Lock & Key 40 Mm (Godrej / Navtal) , Lock & Key 65 Mm (Godrej / Navtal) , Battery Eveready / Nippo Big Size , Battery Eveready / Nippo Medium Size , Battery Eveready / Nippo Size Aa , Battery Eveready / Nippo Size Aaa , Glucometer Battery , Laryngoscope Bulb , Cotton Thread , White & Coloured , Rexin (Decorated/Plain) , Eraser For Pen & Pencil (Camlin / Nataraj) , Oil Cloth- Best Quality , Colin Glass Cleaner (500 Ml) , Carbon Paper Single Size (Camlin / Kores Brand) , Lifebouy Soap-68 Grm. , Detol Soap - 45 Gm , Indigo- Robin Blue (450 Grm. Pkt.) , Detergent Powder 1 Kg (Tide) , Vim Bar (85Gm) , Sewing Machine Needle (All Size) , Sewing Machine Oil (Usha / Singer) , Sewing Machine Oil (Usha / Singer) , Drawing Pin- 100 Nos. Pkt. (Kores / Camlin Brand) , Rubber Slipper - Bata Size No. 6 , Rubber Slipper - Bata Size No. 7 , Rubber Slipper - Bata Size No. 8 , Rubber Slipper - Bata Size No. 9 , Rubber Slipper - Bata Size No. 10 , Soap Case Plastic (Best Quality) , Razor Blade - 5 Pcs. Pkt (Wilkinson / Topaz) , Washing Soap Ok/Jk/Gk 150Gm , Washing Soda , Ball Pen (Cello/ Mitsubishi) , Century Paper ( White / Red / Pink/ Yellow) , Clip Board - Plastic , Punching Machine - 1 Hole (Kangaro) , Punching Machine - 2 Hole (Kangaro) , Black Board Duster , Torch Light (Led Type) - 3 Cell (Eveready/ Nippo) , Gum Boot - Bata No. 5 , Gum Boot - Bata No. 6 , Gum Boot - Bata No. 7 , Gum Boot - Bata No.8 , Gum Boot - Bata No. 9 , Gum Boot - Bata No. 10 , White Board Marker (Luxor) , Xerox Paper (J. K. Brand) (75 Gsm) , Xerox Paper (J. K. Brand) (75 Gsmsize - A4 , Xerox Paper (J. K. Brand) (75 Gsmfull Scape (Legal) , Xerox Paper (J. K. Brand) (75 Gsmdouble Full Scape , Scale 30 Cm (Apsara) , Pencil (Apsara) , Pen (Blue?Black?Red) Maxwriter , Pencil Sharpner (Natraj) , Pencil Eraser (Natraj) , Scissor (Zebra) Medium Size , Scissor (Zebra) Big Size , Scissor (Metal) Medium Size , Scissor (Metal) Medium Size , Pedal Type Dustbin , Pedal Type Dustbin Small , Pedal Type Dustbin Medium , Pedal Type Dustbin Big , Tissue Paper Roll , Paper Marker Pen (Red/ Green/ Yellow) (Luxor) , Cd Marker Pen (Red/ Green/ Blue/ Black ) (Luxor) , Marker Pen (Big) (Red/ Green/ Blue/ Black ) (Luxor) , Brown Tap Roll (2) - 50 Mtr. (Wonder) , Room Freshener 300 Ml (Best Quality) , Room Freshener Automatic (Kent Type) , Tissue Paper Roll , Door Mat (Best Quality) Size 4 X 2 , Door Mat (Best Quality) Size 1 ½ X 3 , Door Mate With Stick (Grass Type) (Green/Black) 3.5X1.9 , Door Mate With Stick (Grass Type) (Green/Black) 3X1.9 , Door Mate With Stick (Grass Type) (Green/Black) 2.5X1.9 , Wall Clock Quartz Ajanta , Calculator - 12 Digit Casio , Cartridge Paper (Green) Kores Brand , High Light Pen Green / Red / Yellow , Hand Wash (Detol) 225 Ml , White Board A. 2X1.5 B. 4X3 , White Board Duster , Rain Coat (Best Quality) S , Rain Coat (Best Quality) M , Rain Coat (Best Quality) L , Rain Coat (Best Quality) Xl , Rain Coat (Best Quality) Xxl , Doner Refreshment Containing Juice (200 Ml), Water Bottle 500 Ml, Small Size Biscuit Packet , Bar Code Ribbon , Bar Code Sticker Label - (Pack Of 100000 Stickers) , Bar Code Scanner , Smps (Normal) , Smps (Small) , Power Adaptor Laptop , Lan Card , Wireless Access Card , Switch 8 Port (Gigabyte) , Switch 16 Port (Gigabyte) , Switch 24 Port (Gigabyte) , L 3 Switch 24 Port Cisco (Gigabyte) , Climping Tools (D. Link) , Media Convertor (Gigabyte) Optic To Lan (Make & Model Tp Link Ms5210cs & M220l) , Sc & Lc Patch Cord , Poe (For Wireless Routers) , Cat 6 Cable (Lan Cable) D-Link (Per Coil Contain 305 Mtr.) , Optical Fibre Cable 6 Core , Optical Fibre Cable 12 Core , Cat 6 Cable (Lan Cable) D-Link , Rj-45 Connector , Rj-45 Connector , Printer Assosories , 1. Taflon For Hp Laserjet (P1108, M1136 Mfp) , 2. Taflon For Hp Canon (Canon 2900B) , 3. Presure Roller For Hp And Canon Printer (Hp 1108, M1136 Mfp & Canon Lbp2900b) , 1. Motherboard Intel Chipset 945 , 2. Motherboard Intel Chipset G31 , 3. Motherboard Intel Chipset 41 , 4. Motherboard Intel Chipset H61 , 5. Motherboard Intel Chipset H81 , 5. Motherboard Intel Chipset 310 , 1. Ssd 512 Gb , 2. Hdd 1 Tb , 3. Hdd 1 Tb , Ram Ddr Iii 4 Gb , Ram Ddr Iii 8 Gb , Ram Ddr Iv 8 Gb , 1. Power Cable , 2. Usb Cable , 3. Hdmi Cable , 4. Vga Cable , 5. Monitor 18.5 , 6. Monitor 21 , 7. Monitor 32 , 8. Monitor 32(Curve) , 9. Keyboard (Logitech) , 10. Mouse (Logitech) , 11. Ups Battery (Exide) 7 Annual Periodical Maintenance , 12. Air Blower , 13. Screw Driver Set , Water Purifier (Aquaguard) 6 Ltr. Capacity (The Aquaguard Delight Nxt Lite Ro+Mc Water Purifier) , Poe (Power Over Ethernet) For Acess Point , Tonner Chemical Powder (Prodot) 88A , Tonner Chemical Powder (Prodot) 12 A , Tonner Drum (Prodot) 88A , Tonner Drum (Prodot) 12 A , Computer Continuing Paper (Lotus) (10X12) (Pkt. Of 1000 Sheets) , Printer Ribbon For Dot Matrix Printer (Prodot) , Ups (600W-220-240V) Frontech , Pen Drive 64 Gb (Sony) , Smps (Frontech/Intex/Umax) , Hard Disk Ssd (Internal) 500 Gb (Laptop) , Hard Disk Ssd (Internal) 1 Tb (Laptop) , Hard Disk Ssd (External) 500 Gb , Hard Disk Ssd (External) 1 Tb , Scanner (Hp Scanjet 200 Flatbed) Make:Hp , Dot-Matrix Printer (Tvs Msp 240 Printer 9 Pin) , Printer Head (Tvs Msp 240 Printer 9 Pin) , Printer (Colour) Model No. L130 (Epson) , Printer Cum Scanner Model No. L3110 (Epson) , Laserjet Printer Hp P1108 , Laserjet Printer Hp Mfp (1188A) , Laserjet Printer Cannon (Lbp2900b) , Printing Tonner Dismat 12A Competitive Black , Printing Tonner Dismat 88A Competitive Black , Printing Tonner Dismat 36A Competitive Black , Toner For Xerox Machine , A. Cannon 2420L , B. Canon Image Runner-2206 , C. Kilburn Km 1635 (Kyocera) , D. Bizhub 206 (Konmica Minolta) , Printer Cartridge , Hp Ink Jet 802 (Black) Big (Original) , Hp Ink Jet 802 (Color) Big (Oroginal) , Hp Ink Jet 802 (Black) Small (Original) , Hp Ink Jet 802 (Color) Small (Original) , Hp Ink Jet 803 (Black) Big (Original) , Hp Ink Jet 803 (Color) Big (Oroginal) , Hp Ink Jet 803 (Black) Small (Original) , Hp Ink Jet 803 (Color) Small (Original) , Hp Ink Jet 21 (Black) (Original) , Hp Ink Jet 22 (Color) (Original) , Hp Ink Jet 27 (Black) (Original) , Hp Ink Jet 28 (Color) (Original) , Hp Laserjet P-1106 (Original) , Hp Laserjet P-1108 (Original) , Hp Laserjet 1020 (Original) , Hp Laserjer -4100 (Original) , Laserjet Printer Cartridge- 12 A , Laserjer Printer Cartridge -88A , Hp Laserjet-P1505 (Original) , Hp Laserjet M1136 Msp (Original) , Cannon Lbp-2900 (Original) , Cannon Lbp-3000 (Original) , 12A Cnnon-1200 (Original) , Cannon 103-303 (Original) , Cannon Mf13010(C) (Original) , Laserjet Printer Cartridge Model No: Hp 110A , Laser Printer Cartridge Model No: Mfp 1188A , Laser Printer Cartridge Model No: 108A , Laser Printer Cartridge Model No: 108A , Ink Cartridge Hp 678 (Black) , Ink Cartridge Hp 678 (Colour) , Epson Ink For Tank Printer L130 , Epson Ink For Tank Printer L3110 , Printer Cartridge Hp - Gt51 (Black) , Printer Cartridge Hp - Gt52 (Color) (Yellow/Blue/Maganta) , Blank Disc 700 Mb (50 Cd) Moserbeer/Sony , Ssd Hard Drive 512 Gb (Frontech) , Ssd Hard Drive 1 Tb (Frontech) , Monitor 27 Inch (Frontech) , Central Processing Unit (Hp/Lenovo) Specification: Intel Core I3-11Th Gen Or Above, 8Gb Ram Ddr3, 512 Tb Hard Drive, Windows 10 Professional Original , Multifuction Lan Adaptor (Usb To Lan) , Usb Wi-Fi Receiver (Wireless Network Card Adaptor) , Webcam (Logitech) , Compressor For 1 Ton Split Ac (L.G) , Compressor For 1 Ton Split Ac Samsung , Compressor For 1 Ton Split Ac Voltas , Compressor For 1.5 Ton Split Ac (L.G) , Compressor For 2 Ton Split Ac Samsung , Compressor For 2 Ton Split Ac Voltas , Compressor For 2 Ton Split Ac (L.G) , Compressor For 2 Ton Split Ac Samsung , Compressor For 2 Ton Split Ac Voltas , Fan Motor 1 Ton Split Ac (Indoor) , Fan Motor 1.5 Ton Split Ac (Indoor) , Fan Motor 2 Ton Split Ac (Indoor) , Fan Motor 1 Ton Split Ac (Outdoor) , Fan Motor 1.5 Ton Split Ac (Outdoor) , Fan Motor 2 Ton Split Ac (Outdoor) , Copper Pipe With Insulation For Split Ac ¼ , Copper Pipe With Insulation For Split Ac ½ , Copper Pipe With Insulation For Split Ac 3/8 , Copper Pipe With Insulation For Split Ac 5/8 , Capacitor For Split Ac , Capacitor For Split Ac 55/60 Mfd , Capacitor For Split Ac 50+2 Mfd , Capacitor For Split Ac 50+6 Mfd , Capacitor For Split Ac 45 Mfd , Capacitor For Split Ac 30+2 Mfd , Capacitor For Split Ac 30 Mfd , Capacitor For Split Ac 36 Mfd , Capacitor For Split Ac 40+4 Mfd. , Pcb For 1 Ton Split Ac , Pcb For 1.5 Ton Split Ac , Pcb For 2 Ton Split Ac , Pcb (Universal) , Drier For Refrigerator , Drier For Air Conditioner , Drain Pipe For Air Conditioner , Fan Motor For Window Ac 1 Ton , Fan Motor For Window Ac 1.5 Ton , Fan Motor For Window Ac 2 Ton , Compressor For Window Ac 1 Ton , Compressor For Window Ac 1.5 Ton , Compressor For Window Ac 2 Ton , Selector Switch Set For Window Ac Standard , Refrigerant Cylinder With Refrigerant For R 22 (2 Kg Capacity) , Refrigerant Cylinder With Refrigerant For R 22 (5 Kg Capacity ) , Refrigerant Cylinder With Refrigerant For R 22 (10 Kg Capacity ) , Refrigerant Cylinder With Refrigerant For R 32 (2 Kg Capacity) , Refrigerant Cylinder With Refrigerant For R 32 (5 Kg Capacity ) , Refrigerant Cylinder With Refrigerant For R 32 (10 Kg Capacity ) , Refrigerant , Refrigerant R 22 , Refrigerant R 32 , Refrigerant 134-A , Refrigerant R 410 , Adoptor (16/5 To ¼) , Refrigerant Cylinder With Refrigerant For R 410 (2 Kg Capacity) , Refrigerant Cylinder With Refrigerant For R 410 (5 Kg Capacity ) , Refrigerant Cylinder With Refrigerant For R 410 (10 Kg Capacity ) , Refrigerant Hydro Carbon , Butane , Bazing Rod Standard Size , Antimoist (Pkt 5 Pcs) , Antimoist , Compressor For Refrigerator , Compressor For Refrigerator ¼ Hp , Compressor For Refrigerator ½ Hp , Compressor For Refrigerator 1/6 Hp , Compressor For Refrigerator 1/8 Hp , Thermostat For Refrigerator , Thermostat For Window Ac , Box Relay , Box Relay Split Ac , Box Relay Window Ac , Relay + Olp Set For Refrigerator , Relay + Olp Set For Refrigerator ¼ Hp , Relay + Olp Set For Refrigerator ½ Hp , Relay + Olp Set For Refrigerator 1/6 Hp , Relay + Olp Set For Refrigerator 1/8 Hp , Fan Motor For Refrigerator (Frost Free) , Defrost Heater For Refrigerator , Bimetal Thermostat For Refrigerator , Thermal Fuse For Refrigerator , Pcb For Refrigerator , Condenser For Refrigerator , Condenser For Refrigerator 175 Litrs , Condenser For Refrigerator 210 Ltrs , Condenser For Refrigerator 260 Ltrs , Condenser For Refrigerator 310 Ltrs , Evaporator Chamber 175 Litrs , Evaporator Chamber 210 Ltrs , Evaporator Chamber 260 Ltrs , Evaporator Chamber 310 Ltrs , Deforst Timer For Refrigerator , Capilary Tube (Expansion Valve) , Fly Nut ¼ , Fly Nut 3/8 , Fly Nut ½ , Fly Nut 5/8 , Union 3/16 , Union ¼ , Union 3/8 , Union ½ , Union 5/8 , Connector (40-60 A) , Connector (40-60 A)Double Pole , Connector (40-60 A)Single Pole , Thermostatic Expansion Valve R 134A, Coolar, 20C-80C , Desktop Computer: Intel Core I3-13Th Gen Or Above, 8Gb Ram, 5.12 Gb Hard Drive, 18.5 Led Monitor, Windows 10 Professional Original, Keyboard And Optical Mouse, Lan, Ups (Make: Hp) , Desktop Computer: Intel Core I3-13Th Gen Or Above, 8Gb Ram, 5.12 Gb Hard Drive, 18.5 Led Monitor, Windows 10 Professional Original, Keyboard And Optical Mouse, Lan, Ups (Make: Lenovo) , Laptop 15.6 : Intel Core I3-13Th Gen Or Above, 16Gb Ram, 5.12 Gb Hard Drive (Ssd), Windows 10 Professional Original (Make: Lenovo) , Laptop 15.6 : Intel Core I3-13Th Gen Or Above, 16Gb Ram, 5.12 Gb Hard Drive (Ssd), Windows 10 Professional Original (Make: Lenovo) , Split Air Conditioner 1 (One) Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Star Rating) (Make: Samsung) , Split Air Conditioner 1 (One) Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Star Rating) (Make: Voltas) , Split Air Conditioner 1.5 Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Star Rating) (Samsung) , Split Air Conditioner 1.5 Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Star Rating) (Voltas) , Split Air Conditioner 2 Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Stars Rating) (Samsung) , Split Air Conditioner 2 Ton Inbuilt Stabilizer Including Stand (Both Indoor & Out Door) & Installation Charges (3 Stars Rating) Voltas , 183 Ltrs Refrigerator Single Door Rating 4 (Four) Stars Including 1 (One) Year Warranty (Samsung) , 198 Ltrs Refrigerator Single Door Rating 4 (Four) Stars Including 1 (One) Year Warranty (Samsung) , 223 Ltrs. Refrigerator Single Door Rating 4 (Four) Stars Including 1 (One) Year Warranty (Samsung) , 236 Ltr. Refrigerator Double Door Rating 4 (Four) Stars Including 1 (One) Year Warranty Samsung , 256 Ltr. Refrigerator Double Door Rating 4 (Four) Stars Including 1 (One) Year Warranty Samsung , 8 Kg Semi Automatic Washing Machine (Samsung) , 10 Kg Semi Automatic Washing Machine (Samsung) , 11 Kg Semi Automatic Washing Machine (Samsung) , 14 Kg Semi Automatic Washing Machine (Samsung) , 7.5 Kg Washing Machine (Semi Automatic) Samsung , 10 Kg Washing Machine (Semi Automatic) Samsung , 11 Kg Washing Machine (Semi Automatic) Samsung , Digital Bio Matrix Attendance Machine (Minimum 500 Fingerprints Capacity) , Battery For Online Ups Make: Exide Smf Capacity: 12Volt/ 17 Ah , Battery (80Ah) Amaron , Battery (80Ah) Exide , Battery (80Ah) Powerzone , Battery (65 Ah) Amaron , Battery (65 Ah) Exide , Battery (65 Ah) Powerzone , Battery (15 Amp) Amaron , Battery (150 Amp) Exide , Battery (150 Amp) Powerzone , Battery (180 Amp) Amaron , Battery (180 Amp) Exide , Battery (180 Amp) Powerzone , Battery (100 Amp) Amaron , Battery (100 Amp) Exide , Battery (100 Amp) Powerzone , 1 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable , 2 Kva Online Ups 3 Phase ( Back , 3 Kva Online Ups 3 Phase ( Back , 5 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable , 10 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable , 20 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable , 30 Kva Online Ups 3 Phase ( Back-Up Time 30 Minutes Minimum) Alongwith Battery Rack And Interconnecting Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
47.
Defence #9609242 AOC
Tender For Repair, Maintenance And Replacement Of Ht Cables, Gods, Vcbs, Rmus, Transformers And Connected E And M Items At Af Stn Suratgarh; 1 Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles,struts, stays etc and getting out all as specified and as directed by Engineer-In-Charge. 2 All as per item No. 1 here-in-before but in PCC/floor/road 3 All as per item No. 1 here-in-before but depth exceeding 1.5 metre and not exceeding 3 metre 4 Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified. 5 Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all asspecified. 6 M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techniqueand necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure and sealing the end of pipe complete all as specified and directed. 7 M&L for laying GI Tubing light grade 100 mm dia for cable potection in road/ floor all as specified and directed 8 Supplying and laying ofsize 90 mm dia (OD-90 mm & ID-75 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 9 Supplying and laying ofsize 120 mm dia (OD-120 mm & ID-103 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 10 Taking out HT/ LT cable of any size/ description from trenches/ floors/ road/ wall/ pipe/ pole and removing & reusefrom site incl making good the disturbed surfaces to match with existing surface all as directed. 11 Relaying/ Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to panel board/ VCBat existing places or provided by MES forcarrying to other location, upto 33000/11000 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 300 sqmm 3 core obtained from item No.10above with required aluminium cable lugs, heat shrink joints specified and directed.Note:The cableJoints and protection pipe and Earth work (if cable laying new rout)shall be meausred seperatly. 12 Supply, laying in trenches/ with pole, jointing and testing of HT 11 KV rated XLPE insulated, PVC bedded earth system stranded aluminium conductor cable 3 core, 95 Sqmm inclusive all incoming and out-going electric connections, complete all as specified and as directed. 13 All as per item No 12 above but of size 3 core 120 sqmm 14 All as per item No 12 above but of size 3 core 150 sqmm 15 All as per item No 12 above but of size 3 core 300 sqmm 16 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 17 All as per item No 16 above but joint of size 120 to 185 sqmm 18 All as per item No 16 above bu joint of size 240 to 300 sqmm 19 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 20 All as per item No 19 above butjoint of size 120 to 185 sqmm 21 All as per item No 19 above butjoint ofsize 240 to 300 sqmm 22 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 23 All as per item No22 above but straight through joint of size 120 to 185 sqmm 24 All as per item No 22 above but straight through joint ofsize 240 to 300 sqmm 25 S&F in replacement cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 33 KV, 3 core 300 sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed. 26 All as per item No 25 above but indoor type joint 27 All as per item No 25 above but straight through type joint 28 Supply and fixing cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.90m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x20cm x30cm block complete all as specified and as directed by Engineer-in-Charge. 29 Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line including taking down existing cracked/unserviceable pin type insulator complete all as specified and directed. 30 S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator/ polymer including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33KV grade complete incl taking down old/unsv all as specified and directed. 31 Supply and fixing disc type insulators, porcelain vitreous white brown or green, 145mm hight and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductor having working pressure 120 KN for11000 Volts /33000 volts (use suitable string ) with highest voltage capacity 12 KV including taking down existing cracked/unserviceable disc type insulator complete all as specified and directed. 32 Taking down old U/S GO switch any type and size from HT 2/4 poles structures. 33 S & FGang operated switch outdoor type 11000 Volts, 200 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 9 Nos., channel, knife blades, GI pipe medium grade 25 mm dia for operating mechanism worked from ground level , locking arrangement with handle all as specified. 34 S & FGang operated switch outdoor type 11000 Volts, 400 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 12 Nos. with dropout fuse set, channel, knife blades, GI pipe medium grade 40 mm dia for operating mechanism worked from ground level, locking arrangement with handle all as specified. 35 All as per item No 34 but for 33 KV 400 Amp, operating horizontal direction incl taking down old/unsvall as specified and directed 36 S&F in replacement expulsion fuse unit single pole mounted on insulator & steel frame complete with fused barrel (drop out fuse) suitable for 11 KV for current rating upto 20 Amp incl taking down old/unsv fuse unit complete all as specifed and directed. 37 S&F in replacement HT 33 KV outdoor type dropout fuses double stack channel type complete with insulator of rating up to 400 Amps incl taking down old/unsvcomplete all as specified and directed. 38 Repairing / Servicing the Air break isolating switch HT 11 KV 200/400 Amps by replacingthe defective major spares parts including provn of minor bolts nuts etc all as specified and directed.Note: Major spare parts will be measured & paid seperately under relevant items of Sch-A 39 Supply only Male contact/ moving Contact Blade 40 Supply only Female contact/Fix Contact Jaw 41 Supply only Tinned copper Flexible jumper 200A/400 A 42 Supply only MS jumper carrier 43 Supply only Back Connector plate 44 Supply only Petroleum Jelly 45 Dismantling/ Taking down old unserviceable lightning arrestor 11 KV from HT 2/4 poles structures. 46 M&L for HT 11 KV lightening arrestor expulsion type having discharge capacity of 65 KA, suitable for 11 KV HT line includng making connection with existing GI earth wire. 47 S&F of lightning arrestors expulsion type complete with all fittings, suitable for 33 KV grade transmission class, discharge capacity 65KA including brackets, clamps, nuts washers and connecting to 4 mm dia GI earth wire including taking out old unservicable lightining arrester allcomplete all as specified and directed. 48 Supply and fixing of Jumper for HT OH Lines 33/11 KVbus system to GOD and GOD to DO Fuse unit with jumper made of aluminium conductorinsulated with colour coding, (Red Green , Blue) with all conneted item i.e nut bolt, U G clamps etc up to length of size 3 to 5 Mtr all as specified and directed by Engineer -in-charge. 49 Dismantling concrete poles/ struts of any size complete all as specified and directed. 50 Demolition of concrete (coping of PCC/ GI pole/ Road) of any description and in any position 51 Supply and erecting in true vertical position steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxideand two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacingcomplete all as specified and directed.(Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch A). 52 PCC 1:2:4 (nominal mix) type B-2 using 40mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed. 53 PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed. 54 M&L for PCC 1:2:4 type B1 using 20mm graded aggregate in coping of size (0.65x0.55x0.45) Mtr for PCC/RCC/Steel tubular pole complete with 10mm thick cement plaster CM 1:4 on coping surface complete all as specified and directed. 55 M & L for scrapping of old painted surfaces of electric pole covered by dust and other depositedmaterials by cleaningwith wire cup brush on drill /grinderfromsteel tubular pole of length upto 11 metres including cross arms,bracing, clamps etc and painting with one coat of Epoxy zinc phosphate primer and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, all as specified & directed by Engineer-in-Charge. 56 M & L for scrapping existing deteriorated complete removal of old paint bywith wire cup brush on drill /grinderfrom the steel tubular 2 pole structure of 9.0-11.0 mtr height above ground levelwithout removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, including one coat ofEpoxy zinc phosphate primer to the remaining part of pole (i.e above 1.50 mtr height) and its cross arms, bracing, support and all steel members complete all as specified and directed. 57 All as per Ser item No. 56 above but for 4 pole structure. 58 All as per Ser item No. 56 above but for 6 pole structure. 59 Dismantling ACSR or AAC conductor complete all as specified and directed. 60 Supply andfixing aluminium conductor, steel reinforced (ACSR) of following sizes as in overhead conductor including fixing aluminium tapes for binding complete all as specified and directed: -(a) 6/1 x 3.0- Ferret (b) 6/1 x 2.59- Weasel(c) 6/1 x 2.11- Squirrel Note: The weight of the conductor shall be determined as stipulated in Preamble (b) & (c)on Page 384 of SSR-2010 Part-II (Rates). 61 M& L for Stringing of ACSR conductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 62 M& L for Stringing of GI cradle Guaredconductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 63 M&L for restraining of GI wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed 64 Supply and fixing PVC moulded LT Line separator suitable for 4 lines OH system. Make- Denson/Mex-well/JB/Jaipuriya brothers 65 Surface excavation over the areas around the substations not exceeding 45 cm depth and averaging 30 cm deep and getting outspoil inhard & dense soil including levelling the surface. 66 M&L forscreened river sand/ tibba filling on the levelled ground surface/ducts in sub stations/below 2 pole & 4 pole structures etc 67 M&L stone aggregate of size 35 to 40mm spreading over sand layerin the substation areas including proper leveling all as directed and shown at site. 68 M&L stone aggregate of size 20 to 25mm spreading over sand layer in the sub stations areas including proper levelling all as directed . 69 M&L taking out spreadedaggrgate of any size &sieving the aggrgate & dust/ sand & relaying the aggregate after sieving in the sub stations 70 M&L brick work with sub class B brick straight cured on plan exc 6m mean radious built in cm 1:4 71 Rendering/cement plastering 15mm thick on fair faces of brick work or concrete surfaces in Cement mortor 1:4 finished even and smooth without using extra cement 72 S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk),forming holes of Fe 410-W (Gde E- 250) quality without any attachmen use for cable duct cover at substncomplete all as directed. 73 M&L for replacement of earth pit chamber of size 300 x300 mm (internal dimensions) and 450x450mm(External)with PCC 1:3:6 type C-1 , RCC 1:2:4 type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick with 12 mm dia MS hook of suitable size and shape for lifting and MS angle iron frame 50 x 50 x 4 mm including GI funnel with wiremesh complete all as specified. 74 Material and labour for fixing of display Board of 60cmx30cm forearth pit made out of 2 mm thick MS sheet welded on angle iron legs 0.75 mtr long (02Nos) of size 40x40x6mm duly embeddedin PCC block 1:2:4, type B-1, using gradedcrushedstone aggregate, of size 23x23x30cm fixed in ground including necessary earthwork. Display Board shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in- Charge. The following is to be written on the board:- (a) Earth Pit No. -(b)Connected To -(c) Checked on -(d) Next due date.-(e) Ohmic Value 75 Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) in and around electrical sub stations, two/four pole structures and removing rubbish to a distance upto 50 metres outside the periphery of the area, complete all as specified and as directed by Engr-in-Charge. 76 Supply and fixing of synthetic insulating matsuitable for 11 KV installation of size 1.00 m x 2.00 m and 25mm thick (ISI marked) complete all as specified and directed. 77 Supply and fixingEarthing dischard rod(ISI Marked), extendable upto 18 feet height with rubber hand grip and suitable size copper wire suitable for working with 11 KV HT lines complete all as specified and directed. Make: Jaipuria/Rashtriya Electricals 78 Supply and fixAluminium thimble/lugs suitable for 50 sqmm to 95 sqmm XLPE cable all as specified and directed. 79 Supply and FixAluminium thimble/lugs suitable for 120 sqmm to 185 sqmm XLPE cable all as specified and directed. 80 Labour for disconnecting LT/HT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectification LT/HT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engineer-in-charge.Note: joint kit will be measured seperately in appropriate item in this schedule 81 Labour only for disconnecting LT/HT cable of any size from pole (height 7.5 to 9 mtr) /transformer/panel and re-connecting ofcable at both endafter removing carbon /burnt insulation part of cable by cutting refixing cable withnew cable lugs . The entire repair work to be completed with in 06 hours of instruction from Engr-in-charge all as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs 500/- per daywill be recoverd per complaint. 82 M&L for earthing complete with GI earth plate 600x600x6mm thick electrode and 32x6 mm GI strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to GI strip earth lead by means of bolts, nuts, check , nuts and washers of galvanised iron or steel all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note: GI stripbeyond 7.5Mtr length from earth electrode shall be measured and paid separately). 83 All as per item No 82 above but with 4 mm dia GI wire as earthing lead andGI protection pipe 20mm dia medium grade. 84 M&L for earthing complete with copper earth plate 600x600x3.15mm thick electrode and 20x3 mm copper strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to copper strip earth lead by means of bolts, nuts, check , nuts and washers of copper all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note : Copper strip & GI pipe 40mm dia beyond 7.5mtr length from earth plate shall be measured & paid separately under respective item) 85 S&F earthing strip 32x6mm GI fixed to wall/pole/buried in ground /drawn in pipe complete. 86 S&F earthing strip 20x3.0 mm copperfixed to wall/pole/buried in ground /drawn in pipe complete. 87 S&F GI wire 4mm dia iron fixed to wall/pole/buried in ground /drawn in pipe complete. 88 S & F Danger notice plate for HT poles size 1.6 mm thick mild steel sheet vitreous enemelled white letter figures and converntionl skull and bones maked in red colour with MS clamp of flate iron 25X3mm size, bolts, nuts, size of plate 25 X20 Cm complete all as directed by Engineer-In-Charge. 89 Dismantling unserviceable any size of cross arms from pole /structures/anti-climbing device etc complete allas specified and directed. 90 M&L for MS work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer all as directed by Engineer-In-Charge. 91 M&L for anti climbing devices, spike type fabricated out of MS bars (Round, square and flat) including nuts, bolt, washers and welding in two halves made to shape to suit the cross section of the pole including painting etc complete all as specified and as directed. 92 Cutting/trimming of tree branches under OH LT/HT electric line including cleaning upto 3.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers smal bushes etc of under OH line upto 60 mitre each span complete all as specified and directed.Note: Materials/T&P like Axies, Daw, rope and the like will be provided by the contractor without any extra cost to the Govt. 93 M&L for stay assembly complete with MS stayplate 300x300x6mm thick galvanized stay rodnot less than 20mm dia, 2.15 M long galvanized stay bow, galvanized thimble,stay clamp etc. all as shown in electrical plate No1of SSR part-I.Note:- Excavation,earthwork,cement concrete loop type insulators and stay wire shall be measured and paid separately under relevant items. 94 M&L for Galvanised stay strand, size 7/4mmcomplete. 95 M&L for loop insulator, vitreous, porcelain, white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5 mm complete. 96 Overhauling/ servicing /calibration of HT VCB 400/630 Amps 33 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v)Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare parts shall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 97 Overhauling/ servicing /calibration of HT VCB 400/800 Amps 11 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v) Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare partsshall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 98 Supply and fixing in replacement microprocess numerical relay for 33/11 KV VCB tripping system ( 03 Over Current/02 O/C , 01 Earth Fault and high set instantaneous protection in single unit) suitable for opration on 24V DC-110V DCall as per Model No CGI14N/CGI4C of Make: Crompton Greaves or equivalent in AREVA(Note:ifExisting relays are of Electromagnetic type, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 99 Supply and fixing in replacement Ammeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh (Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 100 Supply and fixing in replacement voltmeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh(Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 101 M & L for Vaccum Interrupter type WL-33379 or as per exixtingsuitable for 11 KV VCB Panelcomplete all as specefied and directed. 102 M & L for Isolating contact assembly 400/800 Amps with complete set of contact (set of six) suitable for 11 KV VCB Panelcomplete all as specefied and directed. 103 Supply and fixing in replacement indicator lamp assembly 24V DC in (Red,Yellow, White, Green & Blue colour) for HT panels complete all as specified and as directed. 104 Supply install, testing and commissioning in replacementof Power packunit input voltage 90-270 Volts and out put voltage 24 Volts DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unitcomplete all as specified and as directed 105 Supply install, testing and commissioning in replacement of Power packunit input voltage 110 Voltage and out put voltage 24 Volt DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unit complete all as specified and as directed 106 Supply and fix Motor cut off switch complete all as specified and directed 107 Supply and fix ZZ Switch complete all as specified and directed 108 Supply and fix HRC Kit kat fuse 2A, 4A,6A ,10A & 20 A complete all as specified and directed 109 Supply and fix Closing coil 24V DC complete all as specified and directed. 110 Supply and fix Tripping coil 24V DC complete all as specified and directed 111 Supply and fix of Multifunction meter (V,A,P,PF) for 11 KV VCB as per existing sample complete all as specified and directed. 112 Supply and fix of Big gear and small gear set complete all as specified and directed. 113 Supply and fix of TNC switch 11 KV/33 KVpanel complete all as specified and directed. 114 Supply and fix Segment gear complete all as specified and directed. 115 Supply and fix of 11 KV Spring charging motor 220V AC/DC complete all as specified and directed. 116 Supply and fix Motor & Gear assembly 110V DC and 220 ACfor 11 KV VCB Panelcomplete all as specefied and directed. 117 M&L for painting to VCB,Fire stand post ,duct plate etc atinstallations with two coats of synthetic enamel paint after making the suface free from oil/grease/rust and applying a coat of red oxide primer complete including writing details as per directed like as SM Nos/feeder detail etc. all as specified and as directed. 118 S & F in repair Aux relay Buch/WTI/OTIfor 11 KV VCB panel ,Auxiliary supply 24Volt DC as per existing complete all as specified and directed. 119 S & F Cast resin type 11KV VCB three phase current transformer having ratio 100+50/5+5Aas per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second 120 S & f 11KV VCB three phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level 35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156 121 S&F in replacement HT fuse wire upto 60 amp asper site requirement mounting on insulator of 2 Pole/4 Pole structure complete with fused barrelfor 11 KV complete all as specifed and directed. 122 Disconnecting, opening of HT Capacitor bank of any description and any make of rating 11 KV indoor capacitor switching APFC paneland outdoor capacitor bank type with automatic/manual control having output 2400 KVAR (Step rating proposed : 400 KVAR x 2+800 KVAR x 2 desired 0.99) for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etcand replacement of unserviceable parts with new one, reassembling the HT Capacitor Bankafter overhauling/ servicing and its testing complete all a specified and directed. Note:Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch A as supply only 123 Spply only HT HRC Fuses suitable for 11 KV, 400 KVAR complete all as specified and directed. 124 Spply onlyHT HRC Fuses suitable for 11 KV, 800 KVAR complete all as specified and directed. 125 Spply only NDVR Relay suitable for 400 KVAR step complete all as specified and directed. 126 Spply only Contactor coil 127 Spply only Copper bus bar 50x10 mm length 1 mtras per site requirement 128 Dismantling and taking down by removing HT and LT connection of indoor /outdoor type 11/0.433 KV transformer of capacity up to 200 KVA from existng platform/4 Pole/inside sub station Lowering the same carefully and shifting to other location within Air force station(both tech & resdential) as directed by Engineer-in-charge with and including re-installation by means of arrangement and testing and including additional/alterationfoundation according manufactures complete all as specified and directed . Note : (a) Installation of transformer , testing and connecting the both HT/LT cables , commissioning of transformer after checking voltage and loading at full load shall deemed to be included in quoted rates .(b) Contractor shall provide necessary tripod, chain & pulley, T&P, etc for transportation, the rent and foundation for additional/alteration shall deemed to be included in the quoted rate. 129 All as per srl item No128, abovebut capacity of transformer more than200 KVA andupto 500KVA complete all as specified and directed . 130 Repair to distribution transformer step down 11/0.433 KV indoor/outdoor type of capacity 100 KVA to 250 KVA, after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete, taking out the core and winding by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper/aluminium wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, varnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engineer-in-Charge. Note :- (i) Winding wire for making of coils, HT/LT bushes, new transformer oilwill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 131 All as per Srl item No 130 above but of capacity 11 / 0.433 KV, above 250 KVA upto 630 KVA complete all as directed. 132 S & F in replacement brass terminal rod with nuts , boltswasher and bushing suitable for HT and LT side of the transformer of any make and capacity upto 200 KVA complete all as specified and directed . 133 All as per srl item No132, abovebut capacity of transformer more than200 KVA andupto 630KVA complete all as specified and directed . 134 S & F in replacement tap changing switch suitable for operation on 11/0.433 KV distribution transformer with tappings on 2.5% , 5% and 7.5% on requirement basis for upto 630 KVA capacity transformer complete all as specified and directed . 135 Supply and Filling in replacement superior quality silica jel inside the breather assembly and fixing properly with transformer complete all as specified & directed. 136 S & F in replacementoil valve for drain out/filling in screwed both ends with iron wheel head suitable for transformers up to 200 KVA capacity complete all as specified anddirected. 137 All as per srl item No 136, abovebut capacity more than 200 KVA andupto 630 KVA complete all as specified and directed . 138 M & L for fabrication HT / LT side box covers made of bakelite sheet10 mm thickness with proper nuts bolts incl cutting sheet to required size , drilling holes for nuts/bolts etc complete allas specified and directed. 139 S & F in replacement oil temperature gauge 0 -120 degree analogue dial type for transformer complete all as specified & directed 140 M & L for filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength/ insulation value upto65 KV/40KV (RMS) atstandardgap of electrodes 2.5 mm for one minute in 33 KV/11 KV transformer capacity 3 MVA TO 5 MVA including insulation testing of oil with help of suitable equipments before and after dehydration including BDV Test compete all as specified and directed.Note:(i) Contractorwill have to arrange the dehydration machine and transformer oil dielectric strength testing equipmentas mentioned and same shall be deemed to be included in the item rate quoted.(ii) Test result of transformer oil before and after dehydartion is required to submit by contractor duly signed by all concerned. (iii) The contractor shall ensure that the conservator tanks are full to its level before commencement of dehydration process. (iv) Additional quantity of transformer oil if any required for making the oil level upto the requirement in transformer shall be measured and paid separately as supply and filling but its cost of heating shall be deemed to be included in the rate quoted for above item. 141 Supply and filling transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not be less than 70 KV at 2.5mm gap for reduced level of transformer due to evaporation/ leakage/losses due to dehydration in HT33 KV transformer/HT 11 KV AVR transformer/11 KV distribution transformer all as as specified and directed. 142 Supply only super enameled copper conductor wire of suitable gauge and size as per requirement for rewinding of 33/11/0.433 KV power/distribution transformer complete all as specified and directed . 143 Supply only super enamelled aluminium conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformer complete all as directed. 144 Supplying and fixing in replacement, Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers. 145 All as per Serial item No144 here-in-before butcapacity 200 KVA to 315 KVA 146 All as per Serial item No 144 here-in-before but capacity 400 KVA to 630 KVA 147 Supplying and fixing in replacement, Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andconnecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers and reconnection 148 All as per Serial item No 147 here-in-before but200 KVA to 315 KVA 149 All as per Serial item No 147 here-in-before but 400 KVA to 630 KVA 150 Supplying and fixing in replacement,all unserviceable gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 200 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.(i) The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washersetc. (ii)Joint shall be leak proof and any leakage noticed after repair work shall be rectified by the contractor without any extra cost to the deptt. 151 All as per Serial item No 150 here-in-before butmore than 200 KVAand up to 630 KVA 152 S & F in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers,capacityupto 200 KVA complete all as specified and directed. 153 All as per Serial item No152 here-in-before butcapacity more than 200 KVA and upto 630 KVA 154 Supply and fixing in replacement 3mm thick Sheet glass (each not exceeding 0.9 Sqm) ordinary quality and glazing with oil putty on cabin of OTI and WTI gauge of transformer upto capacity 630 KVA complete all as specified and directed. 155 Supply and fixing in replacement thermometer of transformer upto capacity 630 KVA complete all as specified and directed. 156 M & L for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint (heat resistant type)according to to IS colour code by spray machine including writing MES /SM No. in capital letters of suitable size on body for capacity upto 160KVA transformer outdoor/indoor complete all as specified and directed 157 All as per item No: 156 but capacity above 200 KVA and upto 630 KVA. 158 Repair to distribution Power transformer 33/11 KV outdoor type of capacity 3 MVA to 5 MVA , after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete,replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of all gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable HT bushes, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the Transformer and TTRtesting with complete all as specified and directed by Engineer-in-Charge. Note :- Transformer oil /Winding wirewill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 159 Supply and fix inreplacement WTIrelay suitable for 3.15 MVA /5 MVA transformer control panel completeall as specified and directed by Engr-in-charge. 160 Supply and fix inreplacement OTI relay suitable for 3.15 MVA/ 5 MVA transformer control panel complete incl taking down unsv all as specified and directed by Engr-in-charge. 161 Supply and fixinreplacement Mastertripping relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 162 Supply and fixinreplacement Differntial protectionrelay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 163 Supply, fixing and testingin replacement Buchholz relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 164 Supply and fix inreplacement Over/Under voltage protectionrelay with display suitable for 3.15 MVA/5 MVA transformer/ 33 KV VCBcontrol panel complete with testing and calibrationincl taking down unsvall as specified and directed by Engr-in-charge. 165 Supply & Fixmarshaling box complete with all sensor/Meter/indicatorfor protection of winding temprature , oil temprature etc suitable for 5 MVA/3MVA Transformeror as per existing incl connection andtaking down unsv all as specified and directed. 166 M&L for overhauling of the 11 kV Automatic Voltage Regulator (AVR) involves a comprehensive inspection, cleaning, testing and restoration process to ensure reliable performance and accurate voltage regulation. The scope includes the following :-(a) Initial Inspection: Visual and mechanical inspection of the AVR and associated components to assess overall condition and identify faults or degradation.(b) Dismantling: Safe removal and disassembly of the AVR unit including checking connections, terminals and internal assemblies.(c) Cleaning: Removal of dust, oil, moisture, and other contaminants using appropriate cleaning agents and techniques.(d) Component Testing: Electrical testing of control circuits, sensing mechanisms and regulating components to detect wear, drift or failure.(e) Replacement of minorParts: Replacement of defective or worn-out components such as resistors, capacitors, relays, or control cards with compatible, high-quality spares. 167 (f) Reassembly and Calibration: Reassembling the AVR and performing calibration to manufacturer specifications for optimal voltage regulation performance.(g) Final Testing: Functional testing under simulated or actual load conditions to verify stability, response time and output regulation.(h) Reporting: Preparation of a detailed service report including findings, actions taken, test results and recommendations.Note :- (i) Restore the AVR to its original working condition with improve efficeincy andreliable operation of the 11 KV system.(ii) The above work shall be carried out by the authorised manufacturer and rate for the same are included in this item. Nothing shall be paid extra on this account. Note :- Following Major spare parts will be measured & paid seperately 168 Supply only AVR Carbon roller assemblycomplete all as specified and directed 169 Supply only tag and tail assey AVRcomplete all as specified and directed 170 Supply only B4c limitt switchcomplete all as specified and directed 171 Supply only PCB sensing relaycomplete all as specified and directed 172 Supply only Motor 40 KG with Gearcomplete all as specified and directed 173 Supply only Delta change flip flopcomplete all as specified and directed 174 Supply only TDR 240 V AC complete all as specified and directed 175 Supply only Aux Contactorcomplete all as specified and directed 176 Supply, installation, testing and commissioning of 11 kV, 630 Amp, 3 Pole, Outdoor Type Load Break Switch (LBS) with manually operated gang mechanism, suitable for breaking load current under normal service conditions, complete with insulators, arcing horns, operating mechanism, earth blades, padlocking arrangement and all other necessary accessories for safe and efficient operation ,The LBS shall be mounted on hot dip galvanized steel support structure duly fabricated with base frame, operating pipe, crank and handle, including providing and casting of cement concrete foundation in 1:3:6 type C-2 (using 40 mm graded stone aggregate) with necessary excavation, formwork, curing and finishing smooth, including grouting of bolts and painting of steel structure with two coats of aluminium paint over one coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
Contract Date: Feb 16, 2026 Contract Value : 31.31 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
48.
Defence #9603612 AOC
Tender For Repair / Maintenance And Servicing Of Split Type And Window Type Air Conditioner And Cooling Appliances At Technical Area At Afs Chakeri Kanpur- 1 M&L for servicing of window air conditioner 1/1.5 /2TR at various locations complete by cleaning/ filter/ condenser/ evaporator section with spraying water jet, and brushing, removing of dust/ dirt from air conditioner all over, check allelectric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Cheking of functionally of spares of air conditioners and replacing the defective items supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed by Engr-in-Charge. 3 M&L for servicing of indoor and outdoor units of split type AC of capacity 1.5/2 TR at various locations complete by cleaning of filters, indoor cooling coil, condenser coil with sparying water and brushing, removing of dust, dirt from air condtionersall over heck allelectric connections, checking any leakage by applying soap solution on joints and liquid/ vapour lines properly. Cheking of functionally of spares of air conditioners and replacing the defective items supply under relevant item of schedule & rectifying the defects and put the air conditioners into operation complete all specified and directed by Engr-in-Charge.Note:- 1. Contractor shall be maintane register for record of servicing of AC with date wise completion of job.2.Spares shall be measured & paid seperetely under respective items. 4 All as per item no.2 here in before but tower AC of capacity 3.5 TR 5 Supply only Running capacitor 1.5 MFDMake :ASIAN/ELLYT/EPCOS 6 Supply only Running capacitor 2.5 MFD Make :ASIAN/ELLYT/EPCOS 7 Supply only Running capacitor 4 MFD Make :ASIAN/ELLYT/EPCOS 8 Supply only Running capacitor 6 MFD Make :ASIAN/ELLYT/EPCOS 9 Supply only Running capacitor 36 MFD Make :ASIAN/ELLYT/EPCOS 10 Supply only Running capacitor 45+6 MFD Make :ASIAN/ELLYT/EPCOS 11 Supply only Running capacitor 50+6 MFD Make :ASIAN/ELLYT/EPCOS 12 Supply only Running capacitor 55+6 MFD Make :ASIAN/ELLYT/EPCOS 13 Supply only starting relay 1.5/2.0 TR/3.5 TR Make: Asian/Epcos/renutrol 14 Supply onlythermostate switch with knob suitable for window AC 15 Supply onlyin replacement contactor relay for split/tower AC of capacity up to 3.5 TR AC, 415V, 50Hz, 3 Phase 16 M & L for disconnecting of u/s PCB from the unit of split AC/ window AC transporting to Market for repair/ replacement of defective part required to make servicable& reinstalling with the unit and making connections complete all as per specified and directed by Engr-in-Charge. 17 M & L for disconnecting of u/s PCB from the unit of Inverter type split AC/ window AC transporting to Market for repair/ replacement of defective part required to make servicable& reinstalling with the unit and making connections complete all as per specified and directed by Engr-in-Charge. 18 S & F replacement ofMCB SP 240 Volt 32 Amp 10 KA capacity all as specified and directed by Engineer in Charge. 19 S & F in replacementMetal clad socket industrial 2pin & earth plug of20A, 230V complete suitable for AC Box all as specified and directed by Engineer in Charge. 20 S & F in replacementMetalplug top industrial 2pin & earth plug of20A, 230V complete suitable for AC Box all as specified and directed by Engineer in Charge. 21 Supply only (NRV) suitable for window/split Ac of 1.5/2 TR all as specified and directed by Engineer in Charge 22 Supply,fixing and replacement of Flare nut 6/8all as specified and directed by Engr-in-Charge. 23 Supply,fixing and replacement of Flare nut 5/8all as specified and directed by Engr-in-Charge. 24 Supply,fixing and replacement of Flare nut 3/8all as specified and directed by Engr-in-Charge. 25 Supply,fixing and replacement of Flare nut 1/2all as specified and directed by Engr-in-Charge. 26 Supply,fixing and replacement of Flare nut 1/4all as specified and directed by Engr-in-Charge. 27 Supply,fixing and replacement of Dead nut 6/8all as specified and directed by Engr-in-Charge. 28 Supply,fixing and replacement of Dead nut 5/8all as specified and directed by Engr-in-Charge. 29 Supply,fixing and replacement of Dead nut 3/8all as specified and directed by Engr-in-Charge. 30 Supply,fixing and replacement of Dead nut 1/2all as specified and directed by Engr-in-Charge. 31 Supply,fixing and replacement of Dead nut 1/4 all as specified and directed by Engr-in-Charge. 32 Supply,fixing and replacement of suction valve 6/8 all as specified and directed by Engr-in-Charge. 33 Supply,fixing and replacement of suction valve 5/8 all as specified and directed by Engr-in-Charge. 34 Supply,fixing and replacement of suction valve 1/2 all as specified and directed by Engr-in-Charge. 35 Supply,fixing and replacement of Discharge valve 3/8 all as specified and directed by Engr-in-Charge. 36 Supply,fixing and replacement of Discharge valve 1/4 all as specified and directed by Engr-in-Charge. 37 Supply onlyreplacement OLP relay suitable for 1.5 TR/2.00 TR AC Make :ASIAN/EPCOS/RENUTROL 38 Supply only copper liquid line filter 3 way suitable for copper pipe of 3/8 dia for window/ split AC 39 Supply and fix in replacement Copper pipe 5/8 outer diaall as specified and directed by Engr-in-Charge. 40 Supply and fix in replacement Copper pipe 3/8 outer diaall as specified and directed by Engr-in-Charge. 41 Supply and fix in replacement only Copper pipe 1/2 outer diaall as specified and directed by Engr-in-Charge. 42 Supply and fix in replacement Copper pipe 1/4 outer diaall as specified and directed by Engr-in-Charge. 43 S & F in replacement copper pipe insulation of any size complete suitable for split /Tower AC all as specified and directed by Engr-in-Charge. 44 M&L for dismantaling, disconnecting u/s compressors from Split/window AC of capacity 1.5 TR and replacement with new HSCM compressor (rotary type) on mountings such as rubber pads, nut, bolt, wahers andbreezing suction and discharge lines properly, making electrical connections, checking and leakage at joints and vaccuming the system all as specified and directed by Engr-in-Charge. Note:- Serial Number of compressor & its Make shall be recorded in MB 45 All as per item no. 43 here in before but Rotary Compressor for 2.0 TR AC, 220V, Single Phase. 46 All as per item no. 43 here in before butReciprocating compressor for 1.5 TR AC 220 V. 47 All as per item no. 43 here in before butReciprocative compressor for 2.0 TR AC 220 V. 48 All as per item no. 43 here in beforeScroll compressor of capacity 3.5 TR AC, 415V,50Hz , Three phase 49 M & L transportaion of air conditioner from site to work shop for defecting leakage from the close circuit of window air conditioner 1/1.5/2.0 TR capacity, rectifying the leakageby breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leakcharging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site all as directed by Engineer in Charge.( Note:-Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates. AC shall be transported through proper issue vrs/ gate pass etc.) 50 M & L for dismantling of indoor unitsplitAir conditionerof capacity 1.5/2 TR transportingfrom site to workshop for defecting leakage from the close circuit of split air conditioner ofrectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leakcharging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at siteall as directed by Engineer in Charge.( Note:-Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates. AC shall be transported through proper issue vrs/ gate pass etc.) 51 M & L for dismantling of outdoor unitsplitAir conditioner of capacity 1.5/2.0 TR transportingfrom site to workshop for defecting leakage from the close circuit of Split air conditioner ofrectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leakcharging nitrozen and holding the pressure not less than 24 hours or as specified and directed by Engr-in-Charge & refixing back to its original position at site all as directed by Engineer in Charge.( Note:-Cost of brazzing rod, butane gas cartridge and nitrogen shall be included in the quoted rates. AC shall be transported through proper issue vrs/ gate pass etc.). 52 M & L fordetecting leakage from the close circuit of Tower air conditioner of capacity 3.5 TR rectifying the leakage by breezing of copper rod using by butane gas flame, vaccuming the system after rectification of leakcharging nitrozen and holding the pressure not less than 24 hours& refixing back to its original position at site all as specified and directed by Engr-in-Charge 53 M & L for charging of refrigerent R-22 in window / split AC of capacity 1/1.5/2.0/3.5 TR capacity after detection and rectification of leakage under relevant itemof schedule and testing Complete all as specified and directed by Engr-in-Charge. 54 All as item no. 52 here in beforebutcharging of refiregent R-32 55 All as item no. 52 here in before butcharging of refiregent R-410 56 Supply only refrigerent R-22 gas suitable for split/ window type air conditioner in empty cylinder at AGE E/M-III storeyard complete all as specified and directed.Note: (i) Empty cylinder will be provided by the department for filling up refrigerent.(ii) Refrigerent purchase voucher should be provided by the contractor.(iii) The refrigerent shall be taken on ledger charge with receipt voucher and issued as per requirement complete all as specified and directed. 57 All as item no. 55 here in before butcharging of refiregent R-32 58 All as item no. 55 butcharging of refiregent R-410 59 M&L for disconnecting and dismentaling of blower/ condenser fan motor of window air conditioner of capacity 1.5/2.0 TR transporting for civil workshop and rewinding with super enamelled copper conducter wires of superior quality and assembling with the AC unit and testing and commisioning complete all as specitfied directed by Engr-in-Charge. 60 All as per item no.58 here in before but motor of out door unit of split type air conditioner of capacity 1.5/2.0 TR 61 All as per item no.58 but motor of Tower AC 3.5 TR capacity 62 S&F in replacement of single phase electric motor AC of indoor unit capacity 1.5/2.0 TR split AC as per existing make and sample as per site requirement all as specified and directed by Engr-in-Charge. 63 S&F in replacement of single phase electric motor DC of indoor unit capacity 1.5/2.0 TR split AC as per existing makeall as specified and directed by Engr-in-Charge. 64 Disconnecting and leak almunium condenser coil from split air conditioner of capacity 1.5/2.0 TR and supply & fixingof copper tube condenser coil of suitable size as per sample and make and fixing with the outdoor unit of air conditioner vaccuming the system complete and commissioning after fixing complete all as specified and directed by Engr-in-Charge. 65 S&F replacement sheet metal enclosure, 32 Amp single pole and nutralwith a two pin and earth plug socket complete metal clad board (industrial type withMCB 32 Amp fix properly all as directed by engr-in-charge. 66 M & L for factory made MS angle iron stand of suitable size to mount outdoor unit of capacity1.5/2.0 TR split AC complete all as specified and directed. 67 S & FNylon stranded PVC flexible pipe Drain pipe of size 15 mm as per sample all as specified & directed by Engr-In-charge. 68 S & F in replacement PVC insulated & sheathed round multi stranded copper conductor 2.5 sq mm 3 core 1100 Volts graded. 69 Supply and fix in replacement fan blade for window AC of 1.5/2.0 TR capacity as per existing make and sample and as specified and directed by Engr-in-Charge. 70 S&F replacementof condenser fan blade of outdoor unit of split type air conditioner 1.5/2.0 TR capacity as per make & sample and all as specified and directed by Engrin Charge. 71 M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of window AC of cap of 1.5/2.0 TR of any make/modelincluding testing and commitioning all as specified & directed by Engr-in-charge. Note :- Serial number of PCB and its Make shall be recorded in MB 72 M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of split AC of cap of 1.5/2.0 TR of any make/modelincluding testing and commitioning all as specified & directed by Engr-in-charge.Note :- Serial number of PCB and its Make shall be recorded in MB 73 M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of inverter type split AC of cap of 1.5/2.0 TR of any make/modelincluding testing and commitioning all as specified & directed by Engr-in-charge.Note :- Serial number of PCB and its Make shall be recorded in MB 74 M&L for disconnecting of burnt PCB from the unit and supply and fixing of new PCB of Tower AC of cap of 3.5 TR of any make/modelincluding testing and commitioning all as specified & directed by Engr-in-charge.Note :- Serial number of PCB and its Make shall be recorded in MB 75 S&F in replacement of condenser fan motor including mounting base, rubber, clips, as per existing make and soft length in split type AC of 1.5/2.0 TR capacity complete all as specified and directed. 76 S&F swing motor any type, split/ window type AC of 1.5/2.0 TR capacity complete all as specified and directed. 77 M & L for rewiding of burnt transformer of voltage stablizer of capacity 5 KVA with super enameled copper conducter winding wire and assembling with the stablizer complete all as specified and directed by Engr-in-Charge. 78 S & F in replacement of relay 25/30 AMPS 24 volt make and capacity of 5 KVA voltage stabilizer complete all as specified & directed. 79 S & F in replacement of main PCB with high and low voltage cut off PCB suitable for 5 KVA voltage stabilizer suitable making for existing all as specified & directed. 80 S & F window AC kit for 1.5 TR (with and including fans & Compressor of approved make) complete all as specified & directed. Make:- Voltas, LG & Carrier, 81 Shifting of existing split type A/C of any capacity from one location to another location complete pumping down refrigerant gas into compressorincluding disconnecting electrical/ gas connections and making good disturbed surface inCM (1:4)with existing one and its installation by making necessary electric connection incl brazing and refixing complete all as directed. 82 M & L for applying Coil Saver Spray on copper pipe & condensor coil ofWindow/ Split type ACcomplete all as specified & directed. 83 Supply,fixing and replacement of Timer tower AC complete all as specified & directed. 84 Supply of New remoteof make as per OEM of AC with and including suitable battrtery complete all as specified & directed. 85 Supply,fixing and replacement of coling coil senser complete all as specified & directed. 86 Supply & fixing in replacement of remote battery complete all as specified & directed. 87 M & L for Disconnecting water cooler of any sizefrom main power and taking out for carrying out necessary repair/service/maintanance to check serviceability of compressors, fan motor , capacitor,thermostates, switches, gas leackage , push taps,fan blades,relays,over load protectors, condensor coils and any otyher spares required to make the water cooler functionaland fixing in origional / existing position complete all as specified and directed. 88 S & F in replacement Push cock, of brass chromium plated, 15 mm bore, complete all as specified. 89 S & F in replacement 15 mm bore PTMT float valve assembly with PVC floatfor water coolercomplete all as specified and directed. 90 S & F in replacementcombination relay unit complete suitable for water cooler 40 to 150 litre capacity complete all as specified and directed. Make: RANUTROL/ INDFOS/ KIRLOSKAR/ SRI RAM/HI TECH. 91 S & F in replacement copper condenser coil suitable for water cooler 40/80 litre capacity as per existing sizecomplete all as specified and directed. 92 S & F in replacement copper condenser coil suitable for water cooler 80/150litre capacity as per existing sizecomplete all as specified and directed. 93 S & F in replacement thermostat switch suitable for water coolerincluding knob plate and screw complete all as specified and directed. Make: INDFOS/RANUTROL/ SRIRRAM/USHA/HI TECH. 94 S & F in replacement condenser fan motor not less than 1/5 HP or as requiredcompletesuitable for water cooler complete all as specified and directed. Make: AMERICAN UNIVERSAL/USHA/AIR MASTER/COOLER MASTER. 95 Disconnecting old defective burnt sealed compressor unit of water cooler of capacity 40/80 Ltrs and replacement of same with new sealed compressor unit as per sample and including soldering of copper pipes, foundation rubber bushes, nut bolts cleaning the refrigerant system complete all as specified and directed. Note:- Serial Number of compressor & its Make shall be recorded in MB 96 Disconnecting old defective burnt sealed compressor unit of water cooler ofcapacity60/120and replacement of same with new sealed compressor unit as per sample and including soldering of copper pipes, foundation rubber bushes, nut bolts cleaning the refrigerant system omplete all as specified and directed. Note:- Serial Number of compressor & its Make shall be recorded in MB, 97 Testing of water cooler vacumising properly and rectification of leakage in entire system and making the gas system leak proof by brazing/welding charging of refrigerent R-22 to the entire satisfaction of Engineer-in-Charge. 98 M & L for factory made ms angle moter stand of suitable size to mount of water cooler capacity of any size and including two coat of synthetic enamel paint and a coat of red oxide primer complete all as specified and directed. 99 M & L for disconnecting refrigerator from main power to carry out necessary servicing and checkups to maintain efficient working throughout the season/year by checking, cleaningall parts all as directed by Engg-in-charge 100 Disconnecting old defective burnt sealed compressor unit of Refrigerator 150 to 180 Liters capacity of any make and replacement of same with new sealed compressor unit including soldering of copper pipes, foundation rubber bushes, nuts bolts, cleaning the refrigerant system and testing complete all as specified and directed. Make: KIRLOSKAR/ KELVINATOR/ GODREJ/ WHIRLPOOL/LG.Note :- Serial number of compressor and its Make shall be recorded in MB. 101 Cleaning the gas system along with rectification of leakage in the system of 165/190/290/310 litres capacity refrigerator and charging of refrigerent 134A complete all as specified and directed. 102 S & F in replacementDC freezer fan motor of refrigeratorsuitable for any make and capacity complete all as specified and directed. 103 M & L for disconnecting Deep freezerfrom main power to carry out necessary servicing and checkups to maintain efficient working throughout the season/year by checking, cleaningall parts all as directed by Engr-in-charge 104 Disconnecting old defective burnt sealed compressor unit of Deep freezer 500Liters capacity of any make and replacement of same with new sealed compressor unit including soldering of copper pipes, foundation rubber bushes, nuts bolts, cleaning the refrigerant system and charging of refrigerant and testing complete all as specified and directed. Make: KIRLOSKAR/ KELVINATOR/ GODREJ/ WHIRLPOOL/LG. Note :- Serial number of compressor and its Make shall be recorded in MB. 105 S & F in replacement starting relay assembly suitable for Deep freezer up to 500litres capacity complete all as specified and directed.Make: RANUTROL/ INDFOS/HI TECH. 106 S & F in replacement thermostat switch with defrostingarrangement suitable for Deep freezer up to 500 capacity including knob plate and screw complete all as specified and directed. Make: INDFOS/ RANUTROL/ HONEY WELL/HI TECH. 107 S & F in replacement over load protectorsuitable for deep freezer complete all as specified and directed. Make: SHRIRAM/ RANUTROL/ KIRLOSKAR/HI TECH. 108 S & F in replacement condenser fan motor not less than 12 watt or as requiredcompletesuitable for deep freezer complete all as specified and directed. Make: AMERICAN UNIVERSAL/USHA/AIR MASTER / COOLER MASTER. 109 Cleaning the gas system with CTC vacuum pump and charging the Deep freezer R-134A with antimoist substance and filter along with rectification of leakage in the system ofup to 500litres capacity Deep freezer and charging of refrgerent R-290 complete all as specified and directed. 110 M & L for Disconnecting Industrial cooler from main power and taking out for carrying out necessary repair/service/maintanance to check serviceability ofwater pump, fan motor , capacitor, switches, cooler body , water distribution pipes from the desert cooler, removing existing paint/treatment completely preparing the surface and applying externally two coats of synthetic enamel spray paint( as approved) over a coat of red oxide primer (shutters shall be painted all-round i.e. externallyinternally with one coat of synthetic enamel spray paint over a coat of red oxide primer) and paintingcooler body internally with one coat of bituminous paintand refixing only serviceable motor, pump, PVC pipe, distributor and shutters in existing position complete all as specified and directed. 111 M & L for Disconnecting desert cooler from main power and taking out for carrying out necessary repair/service/maintanance to check serviceability ofwater pump, fan 2.motor , capacitor, switches, cooler body , water distribution pipes from the desert cooler, removing existing paint/treatment completely preparing the surface and applying externally two coats of synthetic enamel spray paint( as approved) over a coat of red oxide primer (shutters shall be painted all-round i.e. externallyinternally with one coat of synthetic enamel spray paint over a coat of red oxide primer) and paintingcooler body internally with one coat of bituminous paintand refixing only serviceable motor, pump, PVC pipe, distributor and shutters in existing position complete all as specified and directed. 112 M& L forrewinding fan motor of Industerial cooler with suitable size of super enameled copper wire including replacement of bush, insulating material, greasing, testing and refixing complete after repairall as specified and directed. 113 M & L forrewinding fan motor of desert cooler with suitable size of super enameled copper wire including replacement of bush, insulating material, greasing, testing and refixing complete after repairall as specified and directed. 114 S & FPVC flexible tubing , distributor and elbows and providing PVC flexible tubing distributor and elbows for desert cooler complete all as specified and directed. 115 S & F in replacementsubmersible pump of desert cooler single phase AC, 230 Volts, 50 Hz including necessary connection and testing complete all as specified and directed. Make: POLAR/KHAITAN/GEC. 116 S & F in replacementRotary selector switch with 3 speed for desert cooler/ industerial cooler complete all as specified and directed. Make: ANCHOR/ AGI/ DELITE. 117 S & F in replacement PVC sheathed 3 core cable with copper conductor size 23/0.0076 forDesert cooler complete all as specified and directed. Make: FINOLEX/PLAZA/HAVELLS. 118 S & F in replacement new wooden wool dry pad of suitable size as requiredfor desert cooler of best quality as approved by GE/Engg-in-charge , complete all as specified and directed.
Contract Date: Apr 15, 2026 Contract Value : 31.07 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Uttar Pradesh View Result →
49.
Power #9600390 AOC
Bids Are invited for Amc Of Air Conditioners - Ac 1.5 Ton Window Type(Carrier/Voltas/ Lg/Samsung/Amtex) Etc , Amc Of Air Conditioner - Ac 2.0 Ton Window Type(Lg/Hitachi) Etc , Amc Of Air Conditioner - Ac 2.0 Ton Inverter & Non-Inverter Split Type(Samsung/Hitachi/Bluestar) Etc , Amc Of Air Conditioner - Ac 1.5 Ton Inverter & Non-Inverter Split Type(Bluestar/Haier/ Lloyd/Godrej) Etc , Amc Of Air Conditioner - Ac 4.0 Ton Tower/Split (Make Of Any Brand) , Replacement Items For Split Air Conditioner - Blower Motor , Replacement Items For Split Air Conditioners - Blower Fan , Replacement Items For Split Air Conditioners - Swing Motor , Replacement Items For Split Air Conditioners - Remote , Replacement Items For Split Air Conditioners - Pcb Main-Inv , Replacement Items For Split Air Conditioners - Evaporator , Replacement Items For Split Air Conditioners - Inner Unit , Replacement Items For Split Air Conditioners - Compressor , Replacement Items For Split Air Conditioners - Fan Motor , Replacement Items For Split Air Conditioners - Capacitor For Ac , Replacement Items For Split Air Conditioners - Condensor , Replacement Items For Split Air Conditioners - Capacitor For Fan , Replacement Items For Split Air Conditioners - Pcb Main For Odu , Replacement Items For Split Air Conditioners - Evaporator , Replacement Items For Split Air Conditioners - Condensor , Replacement Items For Split Air Conditioners - Fan Motor , Replacement Items For Split Air Conditioners - Blower Fan , Replacement Items For Split Air Conditioners - Exhaust Fan , Replacement Items For Split Air Conditioners - Pcb Main , Replacement Items For Split Air Conditioners - Compressor , Replacement Items For Split Air Conditioners - Swing Motor , Replacement Items For Split Air Conditioners - Capacitor For Ac , Replacement Items For Split Air Conditioners - Capacitor For Fan , Common Replacement And Other Services Of Air Conditioners - Gas Charging , Common Replacement And Other Services Of Air Conditioners - L
Contract Date: Ref. Documents Contract Value : 14.36 Lakh
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
50.
Public Administrative Department #9500656 Price Bid
Tender For Renovation And Upgradation Work Of 3Rd And 6Th Floor Of Authority Office Building New Building - CIVIL-TOILET SANITARY FITTING WORK 2 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: of area 3 sqm and below. 3 Dismantling Aluminium / Gypsum partitions, doors, Windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge. 4 Demolishing Brick work Manually / by mechanical means including stacking of Serviceable material and Disposal of Unserviceable material within 50 meters lead as per direction of Engineer-in-charge.in Cement mortar. 5 Demolishing R.C.C. work Manually / by mechanical means including stacking of Steel bars and Disposal of Unserviceable material within 50 meters lead as per direction of Engineer-in-charge. 6 Extra for Cutting Reinforcement bars Manually by mechanical means R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work)as per direction of Engineer-in-charge. 7 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm. 8 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 9 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. 10 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 11 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) 12 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 13 12 mm thick cement plaster of mix: 1:4 (1 cement: 4 coarse sand) 14 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes. 15 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes. 16 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes. 17 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm 18 Providing & Placing of Looking Mirror pasted on wall with the help of silicon having edges beveled, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge. Customized 19 Providing & Fixing ofConcealed Stop Cock With Trims as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 20 Providing & Fixing ofFloor Drainer as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent 21 Providing & Fixing ofWall hung Closet with Soft Close Seat Cover Fixed with Jumbo Bolts as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 22 Providing and fixing Urinal With Sensor Make-Kerovit,as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. 23 Providing and fixing Urinal Partition Make-Kerovit,as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. 24 Providing & Fixing of Concealed Cistern With Push Plate as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 25 Providing and fixing of Half/Full Pedestal Basin as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 26 Providing & fixing of Pillar Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Jaquar/American Standard/Kerovit Eqivalent 27 Providing and fixing Sink Mixer as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 28 Providing and fixing 2 Way Bib Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent 29 Providing & fixing Health Faucet as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent 30 Providing and fixing of Angle Cock as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 31 Providing and fixing of Bottle Trap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 32 Providing and fixing of Toilet Paper Holder as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 33 Providing and fixing of Towel Ring as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 34 Providing and fixing of Soap Dispenser as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 35 Providing and fixing of Waste Coupling as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 36 Providing and fixing of Long Braided Hos Pipe as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. 37 Providing and fixing of 110mm dia pipe 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 38 Providing and fixing of 110mm dia Elbow 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 39 Providing and fixing of 110mm dia 45 Degree Elbow, 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 40 Providing and fixing of 110mm dia Socket, 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 41 Providing and fixing of 110mm dia Tee, 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 42 Providing and fixing of 110x110mm dia Nahani Trap, 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 43 CIVIL-INTERIOR WORK ESTIMATE 44 Providing & Fixing of at all height false ceiling including providing and fixing of frame made of special section power pressed from m.s. sheet and galvonised in accordance with zinc coatingof grade 350 as per IS 277and consisting of angle cleat 25x1.6mm with flanges of 27mm and 37mmat 1200mm c/c one flangedfix to the ceiling with dash fastener 12.5mm dia and and 40mm long with 6mm dia boltto the angle hangers of 25x25x0.55 mm of required lengthened other end of angle hanger being fixed with nut and bolts to GI channel 45x15x0.90mm running at the rate of 1200 mm c/c to with the ceiling section 0.5mm thick button wedges of 80mm with tappered flenges of 26 mm each having clips of 10.5mm.at 450mmc/ cshall be fixed in direction perpendicular to GI channels with connecting clipsmade out of 2.64MM diax230mm longGI wire at every junction including fixing the gypsumboard with ceiling section and perimetre channels 0.50 mm thick 27mm high having flenges of 20mm and 30mm long ,perimeter of ceiling fixed to wall /partitionwith help of rawl plugs at 450mm c/c with 25 mm long drive all screws @230mm interval including jointing and fixingto a flush finish of tapperedend sq edge of board with recommended filler jointing and tapper finisher and two coat of primer suitable for board as per manufacturers specification and also including the cost of making of openning for light fittings grills diffusers cutouts made with frame of perimeter channelssuitably fixed all complete as per drawing and specification and direction of engineer incharge but excluding the cost of painting. 12.50mm thick tapered edge gypsum board. 45 Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled Tegular) Edge Tiles With Armstrong 15mm Exposed GRID.The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 63%.The tile shall be laid on Armstrong Suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 8.8 Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre.The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support.600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres. ARMSTRONG SUSPENSION SYSTEM - Armstrong make Anchor Fastener, Hanger Wire 2.5mm dia, Hook Clip with J Wire assembly. Approved Makes - Armstrong, Shera, Nitco. 46 Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing C wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 47 Providing and laying & Repairing Existiting vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 48 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 49 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 50 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 51 Providing & Making & Fixing of Wooden Wall Panelling made with Aluminium Section of 2x1 @ 2CC frame work cladded with 12MM Ply & Finished with 1MM Laminateon One Side complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Architect/Engineer -in-Charge. 52 Providing & Making & Fixing of Wooden Wall Partition made with Aluminium Section of 2x1 @ 2CC frame work cladded with 9MM Ply & Finished with 1MM Laminateon Both Side complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Architect/Engineer -in-Charge. 53 Providing & Making & Fixing of Wooden Wall Panelling made with Aluminium Section of 2x1 @ 2CC frame work cladded with 4MM Veneer complete with Water Base PU Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 54 Providing & Making & Fixing of Wooden Wall Panelling made with Aluminium Section of 2x1 @ 2CC frame work cladded with Coloured Lacquered Glass as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 55 Providing & Fixing of 12MM Toughened Glass Door with all hardwareas per design with edge polish m/c top & bottom pivot and bottom lockwith handle all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 56 Providing & Fixing 12MM Toughned Glass Partition Modi float glass fixed edge to edge as per design and drawing and polished where required along with neccesary hardware all complete as per drawing, specification and direction of engineer incharge. 57 Providing & fixing of 32MM Flush Door complete with all Fittings Like Hinges, Mortis lock, Door closer, Tower Bolt etc all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 58 Providing & Fixing of Plotter Cutted Designer Film of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 59 Providing & Fixing of Plotter Cutted Designer Coloured Vinyl of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 60 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 5 mm shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 61 Providing & Fixing of Roller Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 62 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 63 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 64 Providing & Making & Fixing of Storage Cabinet made of 19MM Board, having shelves & shutters & teak wood beading & finished surface of 1MM Laminate including all hardware like tower bolts, hinges, lock & handle as per approved drawing & direction of Engineer incharge. 65 ELECTRICAL WORK ESTIMATE 66 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A 67 Supply and fixing of Power point and Supply and fixing of power plug with 10 Amp./250 volt flush type modular switch and 5 pin 10A /250 volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. 68 Supply and fixing of wire, Power point and Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 nA/250 volt flush typ[e universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. 69 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 70 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 71 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire 72 Supplying & Drawing co-axial TV cable RG-6 grade, 0.7 mm. solidcopper conductor, PE insulated] shielded with fine finned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required. For T.V. Socket outlet 73 Providing Drawing Connecting And Testing Of Enhanced Categoey 4 Pair Lan Local Area Network Cable 24 AWG Conductor Performance Specifide 5E U L and CUL Listed In Existing PVC Conduit .(CAT-6 Network Cable) 74 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 20MM 75 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 25MM 76 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 32MM 77 Supplying & fixing of TV Antenna socket on Modular Plate & G.I Box including connections 78 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 1 or 2 Module 79 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 3 Module 80 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 4 Module 81 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 6 Module 82 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 8 Module 83 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 12 Module 84 Blank plate for modular plate type switch boards wherever required. 85 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 86 S&F of 125 Amp 4 pole MCCB (25 KA) Thermal Magnetic release 87 S & F surface/Flush mounting 12ways V TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT-A 88 Supply and fixing of recess mounting round15 TO 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AAA 89 Supply and fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA 90 Supply and fixing of 150mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent 91 Supply and fixing of 400mm Wall Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent 92 Supply & Fixing of LED Profile Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 93 Supply & Fixing of LED Profile Light Driver all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 94 Supply and Fixing of Deep Recess Mounting round 10 Watt COB LED Spot Light having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 95 Supply & Fixing of 150MM Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton Grand-6 96 Supply & Fixing of 150MM Gravity Grill For Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton Gravity Grill-6 97 Supply & Fixing of 150MM Air Valve For Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton CAV-6 98 Supply & Fixing of 110MM Ceiling Mount Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton 99 Providing & Fixing of Call Bell Chimes all complete as per drawing and specification and direction of engineer incharge. Make-L&T 100 Providing & Fixing of 1200MM Designer Hanging LED Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledlum 101 Providing & Fixing of Modular plate type white RJ 45 CAT 6 Data/Talephone outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required with RJ-45 Data outlet 102 FURNITURE WORK 103 Providing & Making & Fixing of Conference Table Made of 19MM Board, Topand Vertical drop 19MM ply board. All the surface to be cladded with 1.5 mm Mica & Having S.S Frame Square Section of 302 Grade. All the Edges to be lipped with 4MM Veneer which shall be Water Based PU Polished, all complete as per design approved by E/I & Architect Incharge. Customized 104 Providing & Fixing, Table of Size - COLLABORATE 1800 MM WITH SIDE STORAGE AND WITHOUT HEIGHT ADJUSTABLE EXTENSIONMAIN TABLE - 1800W X 900D X 750HTCOMPOSITE SIDE STORAGE - 1050W X 450D X 750HTThe Collaborate 1800 mm executive workstation is a thoughtfully designed compact desk setup ideal for modern office environments. The main desk measures 1800W x 900D x 750H mm and is crafted with a 25mm thick pre-laminated particle board tabletop, finished with 2mm PVC edge lipping to ensure long-term durability and impact resistance. The tabletop offers a clean and modern appearance suitable for executive and managerial spaces.The workstation is structurally supported by mild steel (MS) powder-coated loop legs, featuring a distinctive 55x55mm diamond profile. These are paired with die-cast metal connectors and reinforced with MS cross beams, ensuring superior strength and stability while adding a refined industrial aesthetic. A front modesty panel made of 18mm thick pre-laminated particle board with 2mm PVC edge lipping, and a standard height of 450mm, ensures privacy without compromising open design.For integrated electrical management, the desk features a 350mm wide metal flip-up cover with a soft closure mechanism, offering concealed access to switchboards and power/data outlets. The MS cable dump tray beneath the tabletop is designed to house switches and sockets efficiently. Additionally, a vertebra-type vertical wire manager (cable spine) is provided for seamless and organized cable routing from floor level to the desk, enhancing safety and aesthetic appeal. Accompanying the main desk is a composite side storage unit measuring 1050W x 450D x 750H mm, constructed from 18mm thick pre-laminated particle board for a consistent and coordinated look. This side unit offers a combination of closed storage and drawers for functional workspace organization. The configuration includes three drawers (2 box drawers + 1 file drawer) along with shuttered compartments, allowing versatile storage for office supplies, documents, and personal belongings. All shutters are equipped with auto-closing hinges to ensure smooth, silent operation. The drawers and shutters feature integrated finger groove handles for a clean, handle-less appearance, and the entire unit is fitted with a central locking system to ensure safety and security of stored materials. Adjustable shelves provide flexibility in internal space utilization, while levellers ensure stable placement even on uneven flooring. All essential hardware components are included, supporting ease of assembly and reliable daily usage.. Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 105 Providing & Fixing, Linear Workstation of Size:- NEO WORKSTATION -1200X600 Specifications - Partition system WITH PARTITION ON MAIN SPINE , INTERMEDIATE AND ENDS The NEO Workstation is a modern, modular workspace solution designed for efficient and ergonomic usage in collaborative office environments. Each workstation measures 1200W x 600D mm and is integrated with a structured partition system that provides defined workspaces with optimal privacy and utility. The system features partitions on the main spine, intermediate panels, and end panels, creating a consistent, enclosed workspace layout. The partition system stands at a total height of 1200mm and is built using a frame structure with top and side aluminium trims, offering a sleek, modern appearance while maintaining structural integrity. All vertical junctions and corners are finished with high-quality die-cast aluminium caps, ensuring clean detailing and long-term durability. The workstation surface consists of a 25mm thick pre-laminated particle board tabletop, finished on all exposed edges with 2mm PVC edge lipping, enhancing durability and resistance to everyday wear. The tabletop offers ample personal workspace, making it ideal for focused individual tasks within a shared environment. Support for the tabletop is provided through 18mm thick pre-laminated gable ends, offering solid lateral stability while maintaining a minimalist design. The gable ends match the tabletop in finish and style, ensuring a unified look across the workstation cluster. For efficient cable management, the workstation is equipped with a 65mm diameter grommet cap on the tabletop for cable entry. Beneath the surface, a metal raceway tile is provided for mounting electrical switches and sockets, ensuring clean and accessible power connectivity. A metal skirting tile is also included below table level, specifically designed for data cable routing along the main spine, ensuring complete segregation and safety of power and data lines. Tile finishes are thoughtfully planned to enhance both utility and aesthetics. Above table level, the partitions feature fabric tiles, offering tackable surfaces for personal pin-up needs. Each workstation includes one glass marker tile for easy jotting of notes and tasks, and one magnetic tile for pinning magnetic objects or accessories. Below the tabletop, pre-laminated tiles are used for durability and easy cleaning, while metal skirting tiles on the main spine facing the user provide a robust, high-utility finish with integrated cable routing., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 106 Providing & Fixing, Linear Workstation of Size:- NEO WORKSTATION -1350X600 Specifications - Partition system WITH PARTITION ON MAIN SPINE , INTERMEDIATE AND ENDS The NEO Workstation is a modern, modular workspace solution designed for efficient and ergonomic usage in collaborative office environments. Each workstation measures 1350W x 600D mm and is integrated with a structured partition system that provides defined workspaces with optimal privacy and utility. The system features partitions on the main spine, intermediate panels, and end panels, creating a consistent, enclosed workspace layout. The partition system stands at a total height of 1200mm and is built using a frame structure with top and side aluminium trims, offering a sleek, modern appearance while maintaining structural integrity. All vertical junctions and corners are finished with high-quality die-cast aluminium caps, ensuring clean detailing and long-term durability. The workstation surface consists of a 25mm thick pre-laminated particle board tabletop, finished on all exposed edges with 2mm PVC edge lipping, enhancing durability and resistance to everyday wear. The tabletop offers ample personal workspace, making it ideal for focused individual tasks within a shared environment. Support for the tabletop is provided through 18mm thick pre-laminated gable ends, offering solid lateral stability while maintaining a minimalist design. The gable ends match the tabletop in finish and style, ensuring a unified look across the workstation cluster. For efficient cable management, the workstation is equipped with a 65mm diameter grommet cap on the tabletop for cable entry. Beneath the surface, a metal raceway tile is provided for mounting electrical switches and sockets, ensuring clean and accessible power connectivity. A metal skirting tile is also included below table level, specifically designed for data cable routing along the main spine, ensuring complete segregation and safety of power and data lines. Tile finishes are thoughtfully planned to enhance both utility and aesthetics. Above table level, the partitions feature fabric tiles, offering tackable surfaces for personal pin-up needs. Each workstation includes one glass marker tile for easy jotting of notes and tasks, and one magnetic tile for pinning magnetic objects or accessories. Below the tabletop, pre-laminated tiles are used for durability and easy cleaning, while metal skirting tiles on the main spine facing the user provide a robust, high-utility finish with integrated cable routing., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 107 Providing & Fixing, MOBILE PEDESTAL 2D1F : 400W X 450D X 600HT The Mobile Pedestal is a compact and durable under-desk storage solution designed for efficient organization of office essentials. With an overall size of 400mm (W) x 450mm (D) x 600mm (H), the pedestal is manufactured from 0.6mm thick Cold Rolled Close Annealed (CRCA) steel sheets, which are powder coated to ensure a high-quality finish that resists corrosion, scratches, and general wear. This unit features a three-drawer configuration, consisting of two box drawers for storing stationery and smaller items, and one filing drawer capable of accommodating hanging files and larger documents. All drawers are mounted on smooth sliding channels, providing seamless and quiet operation during daily use.The pedestal is designed as a mobile unit, equipped with heavy-duty castors that allow for easy movement and repositioning under the workstation or within the workspace. Despite its mobility, the unit maintains structural stability and ergonomic accessibility.A central locking mechanism is integrated into the design, allowing all three drawers to be simultaneously locked with a single key, enhancing document security and user convenience. The compact size allows it to fit easily beneath most standard-height desks while providing ample storage space for individual user needs. This mobile pedestal is an ideal addition to any modern office setup, offering a balance of mobility, functionality, and secure storage. 108 Providing & Fixing, SIDE STORAGE METAL (900X450X1200HT)Supplying and installation of a robust steel almirah designed for office storage applications. The unit shall be installed in a perfectly upright and straight position to ensure alignment, stability, and optimal utility. The overall dimensions of the almirah are 900mm (Width) x 450mm (Depth) x 1200mm (Height), inclusive of integrated legs that elevate the unit off the floor for easy cleaning and enhanced air circulation. The almirah structure is fabricated using high-yield strength Cold Rolled Close Annealed (CRCA) steel sheets of grade D conforming to IS: 513 standards. The door panel is made from 1.0mm thick CRCA sheet, providing added rigidity and durability, while all other structural components are manufactured from 0.8mm thick CRCA sheet to balance strength and weight. For enhanced load-bearing performance, internal stiffeners are integrated within both the shelves and the door, ensuring long-lasting structural integrity and resistance to deformation. Internally, the almirah is equipped with two adjustable shelves, resulting in three loading compartments, each with a clear usable height of approximately 400mm, allowing versatile storage of files, documents, and supplies. The shelves feature a folded construction, which imparts intrinsic rigidity and enhances their load-carrying capacity, capable of supporting up to 40kg of uniformly distributed weight per shelf.The unit is fitted with a steel-hinged door, incorporating a three-way locking mechanism and secured with a 6-lever lock and key. A durable lever handle is provided for smooth and secure operation. All locking components ensure safety of contents and are suited for regular office use.The entire metal assembly undergoes a multi-stage surface treatment process, including iron phosphating for rust resistance, followed by electrostatic powder coating in a finish thickness of 60–80 microns, offering excellent adhesion, abrasion resistance, and aesthetic appeal., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 109 Providing & Fixing, High Back Chairs Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood.Gaslift - Class 4 tested -ANSI BIFMA performance standards.Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002.The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength.Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards.Upholstery: Seat Cushion with pre moulded foam having leatherette tapestery of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Distinctively and characteristically designed tilt mechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratio of 3:7, optimal for good back support.Multilock mechanism is fabricated from CR Sheets, undergo through CO2 welding process imparting uniform surface finish and tensile strength. The components are processed with high degree of precision and care so as to assemble with other parts in perfect harmony to give smooth and effortless reclining experience. Tension springs are made out Grade II material conforming to Indian Standards. Also provided with release levers for locking mechanism and height adjustment of seat. Mechanism aides to operate the height adjustment, and has been equipped with 3 locking positions, back rest “ Return Prevention” function. Back Frame is inserted with leathertte tapestery cushion & Adjustable Lumbar Support.Tension control isbelow the Seat.Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Seat is duly upholstered with approved fabric. Chair will have adjustable headrestChair Should be BIFMA Certified.Seat: Depth- 51.5 cm Width- 44.5 cm Dimensions: Width- 51.5 cm Depth- 53.5 cm Minimum Height- 99.5 cm Maximum Height- 108.5 cm Minimum Seat Height- 44.5 cm Maximum Seat Height- 52.5 cm Width (Arm to Arm)- 66 MODEL, Chair should be BIFMA and Green Guard certified.:- AMAZE HB, Make-Featherlite/Geeken Equivalent. 110 Providing & Fixing, Medium Back Chairs Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood.Gaslift - Class 4 tested -ANSI BIFMA performance standards.Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002.The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength.Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards.Upholstery: Seat Cushion with pre moulded foam having leatherette tapestery of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Distinctively and characteristically designed tilt mechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratio of 3:7, optimal for good back support.Multilock mechanism is fabricated from CR Sheets, undergo through CO2 welding process imparting uniform surface finish and tensile strength. The components are processed with high degree of precision and care so as to assemble with other parts in perfect harmony to give smooth and effortless reclining experience. Tension springs are made out Grade II material conforming to Indian Standards. Also provided with release levers for locking mechanism and height adjustment of seat. Mechanism aides to operate the height adjustment, and has been equipped with 3 locking positions, back rest “ Return Prevention” function. Back Frame is inserted with leathertte tapestery cushion & Adjustable Lumbar Support.Tension control isbelow the Seat.Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Seat is duly upholstered with approved fabric. Chair Should be BIFMA Certified.Seat: Depth- 51.5 cm Width- 44.5 cm Dimensions: Width- 51.5 cm Depth- 53.5 cm Minimum Height- 99.5 cm Maximum Height- 108.5 cm Minimum Seat Height- 44.5 cmMaximum Seat Height- 52.5 cm Width (Arm to Arm)- 66 cm Arm Rest Height- 18- 27.5 cm Chair should be BIFMA and Green Guard certified. AMAZE MB, Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 111 Providing & Fixing, Fixed Leg Chair Made of The frame is made out of 25.4mm tube of 16 gauge tube confirming to IS-7138-1973, Welded by Co2 welding process for uniform surface finish and higher tensile strength perforation on the sheet is of uniform 2.5mm dimension and gives good ventilation.High quality hardware conforming to Hardness 38-44 and tensile strength – 1300 n/mm. IS 1363-1967.Seat is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Japanese T-nuts and riveted in to the plywood.Set and backUpholstery: Cushion with pre-moulded foam of 50 - 60kg/m3 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Injection moulded polypropylene armrests.Leatherette cusion Back on Frame. Back is injected moulded PP.Seat and back are duly upholstered with approved Leatherette. AMAZE VA, Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 112 Providing & Fixing, Single Seater Sofa of Size: 850L X 790D X 790H Seat Foam: the sofa is made up of fine quality leatherette.The structure is made up of silver wood and pine wood.The Seat is made of PU Foam with Density 32 to 40 +/- 2 kg/cu .mtrSeat is upholstered wuth Leatherite.Back Foam: The Back is made of PU Foam with Density 32 to 40 +/- 2 kg/cu, Backis upholstered with Leatherite.Unterstructure is made up of silver wood or pine wood , 4mm Dia zigzag Spring is mounted in the understructure for support and additional cushioning purpose. Legs should be made up of stainless steel tubes/pipes, S-SERIES, Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 113 Providing & Fixing, CORNER TABLE @500 MM DIA, MODEL: CT-2105 MARBLE CORNER TABLE (0.5M), TOP - STONE , BASE - BLACK TIATANIUM. Supplying and installation of a contemporary center table designed to complement modern office and lounge interiors. The table has an overall dimension of 600mm (Length) x 600mm (Width) x 425mm (Height), offering a spacious and proportionate surface suitable for waiting areas, meeting lounges, or collaborative spaces. The tabletop is made from 12mm thick toughened glass, offering high impact resistance and durability. The glass is partially tempered, adding safety features to reduce the risk of sharp breakage. The top profile is square-edged with bevelled edges, enhancing the aesthetics while ensuring user safety through smooth contours and soft corners. The glass top is supported by high-quality vacuum suction caps, securely fixed over the underframe to ensure firm and stable placement without visible fasteners, contributing to a clean, floating appearance. The understructure consists of a stainless steel (SS) frame fabricated from SS 202 grade pipe, known for its corrosion resistance and strength. The pipes used in the frame have a diameter ranging from 20mm to 25.4mm and a wall thickness of 2mm, providing superior load-bearing capacity and structural stability. The frame is finished in a high-gloss chrome finish, offering a sleek, premium look suitable for modern interiors. To protect flooring surfaces and enhance stability, the table is equipped with high-quality PPCP (Polypropylene Copolymer) shoes at the base of each leg. These shoes prevent scratches and scuffs on delicate floors while also absorbing minor impact loads.This center table combines the durability of stainless steel with the elegance of toughened glass, making it a stylish, low-maintenance, and long-lasting addition to any office or hospitality environment., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 114 Providing & Fixing 3 SEATER LEAF TANDOM CUSHION SEAT WITH ARMS Beam & Legs are from uniquely designed MS tubes, the foot are from high pressure diecast aluminium material comes with height adjustable levellers to take care even if there is a floor undulation upto 8-10mm. The Feet, Leg & Beam comes in flat pack, knock down condition and are fixed using zinc passivated best grade hardware. Seat is a plastic injection moulded part in PP material, can be offered with or without cushion & in multiple colours selected from Featherlite shade card based on MOQ. Product can be offered with or without the handle / arms. Arms are from Dia 25mm MS tube fixed with PP arm rest. All Metal & aluminium parts comes with powder coating finish of 60-80 micron thk., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 115 Providing & Fixing, Steel almirah for office purpose in perfectly upright and straight position. The overall size of the almirah shall be 900mm (W) X 450mm (D) X 2015mm (H) including legs. It should be supplied with 4 nos. of adjustable shelves i.e. 5 loading compartments. Each compartment shall be 400 mm high. Door shall be made of 1mm thick and all other components shall be made of 0.8mm thick high yield strength CRCA sheet of grade ‘D’ confirming to IS: 513. Proper stiffeners shall be provided in shelf & door. The steel hinged door shall be provided with lever handle & 3 way locking mechanism with 6 lever lock with Key. The shelves shall have folded constructions which have intrinsic rigidity and high load carrying capacity.Uniformly distributed load capacity per each shelf shall be 40kg maximum. Metal Part should be pre treated with Iron Phosphating with powder coating of 60-80mm thickness, Make-Featherlite/Geeken Equivalent. 116 Providing & Fixing of high bar stool. Specification : Gimlet of size 480(W)X535(D)X810(H)of Approximately 8 kg weight. Make-Featherlite/Geeken Equivalent 117 FIRE ALARM WORK ESTIMATE 118 supplying , installation , Testing & commissioning of ionization smoke detector with builtin LED and mounting base complete with all connections etc. as required. 119 supplying , installation , Testing & commissioning of manual call boxes of MS construction in surface/recess with strainless steel chain & hammer assembly complete with glass and push button etc. as required. 120 supplying , installation , Testing & commissionin response indicator on surface/recess Ms box having two LEDs mettallic cover complete with all connections etc. as required. 121 supplying , installation , Testing & commissionin fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. 122 supplying , installation , Testing & commissioning of main controland indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement , audio and visual indication for fire alarm and public adress system, monitoring system including connections, interconnections etc complete as required. 10 zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required-2 Nos. ( one to act asstanby) Talk back master stationwith LED PTT ( press to talk ) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/ communication suitable for 20 Nos. talk back unit-1 set. Anouncement control desk suitable for selection of different zones selectively and on ALL CALL switch with visual indication etc. complete as required -1 set Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required-1 NO. Gooseneck microphone with stand and ON/OFF switch -1 N0. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeter & ammeters , terminal blocks etc. complete as required-1 set Battery charger trickle cum boost to talk complete load of fire alarm PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 60 AH each sealed maintenanance free batteries-1 set. 123 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 4.5 Kg capacity CO2 type as per IS- 15683complete as per specification and fixed / install as per site condition: 124 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 5 Kg capacity ABC Dry Chemical powderas per IS- 15683complete as per specification and fixed / install as per site condition : 125 Supply,Installation, Testing & Commissioning of CI flanged butterfly valve complete with nuts, bolts & washers etc. conforming IS 780 - 100mm dia 126 Supply,Installation, Testing & Commissioning of CI flanged butterfly valve complete with nuts, bolts & washers etc. conforming IS 780 - 80mm dia 127 Supply,Installation, Testing & Commissioning of of ISI marked cost iron double flanged non return valve as per IS: 5312, Part-1 including transportation to work site, supply and fixing nuts, bolts. Gaskets & washers,etc. - 100mm dia 128 Supply,Installation, Testing & Commissioning of sprinkler heads, 25 mm dia conventional pattern, opera table at 68 129 Supply,Installation, Testing & Commissioning of copper cable 2 - core, 1.5 sqmm armoured cable. 130 Supply,Installation, Testing & Commissioning of of PVC insulated 4 core copper cable for connect main pannel to LCP & PA system 131 VRV AIR-CONDITIONING WORK ESTIMATE 132 Shifting of the present vrv connected ac& Fixing at the final location all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 133 Commissioning of VRV systems including topping R410A gas per site requirementsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 134 Supply & Fixing of 1.5 ton AC all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 135 CCTV SURVEILLANCE SYSTEM WORK ESTIMATE 136 Supply, Installation, testing and commissioning of IP fixed Cameras, Network TDN IR Indoor/Outdoor Camera, 1/3 CMOS, 2 MP, 3.6 mm Fixed, 24 IR LEDs,PoE,H.264complete. Make - Dahua 137 Supply, Installation, testing and commissioning of 32 VMS channel NVR with Embedded enterprise grade linux processor, real-time H.265 Security baseline 2.1, 1080p@30 fps adaptive decoding, ONVIF and RTSP protocols, resolution HDMI 4K, AI Face detection, perimeter protection, IVS, people counting, heat map, and SMD, BW 160 Mbps, Audio PCM/G711A/G726/AAC, privacy masking, video loss, scene changing, PIR alarm, SATA III port up to 10 TB. Make Dahua/HikVision 138 Supply, Installation, testing and commissioning of 6TB SATA Internal with 1M hours MTBF, 180 TB workload rate, write-intensive, low bit-rate, high stream-count, prioritized write-op. Make - WD/Seagate 139 Supply, Installation, testing and commissioning of HDBaseT Hdmi Extender Make - Milestone/Bluestream 140 Providing, Installation, Testing & Commissioning of Hig Performance 1.4a standard HDMI 4K Cable. Make - Extron/Nedis/Logic/DC 141 Supply, Installation, testing and commissioning of wall mountable 55 high resolution LED monitor with HDMI port and commercial series suitable for 12x7 operation. All accessories for installation including wall mounting stand/ bracket. Make - Samsung/Sony 142 WIFI & NETWORKING SYSTEM WORK ESTIMATE 143 Supply, Installation, testing and commissioning of 27 U Rack Make - Dlink/Comrack 144 Supply, Installation, testing and commissioning of Rack Accessories For 27U Rack Make - Dlink/Comrack 145 Supply, Installation, testing and commissioning of Metal Shelf Rack Make - Dlink/Comrack 146 Supply, Installation, testing and commissioning of Horizontal Cable Manager Make - Dlink/Comrack 147 Supply, Installation, testing and commissioning of Cat 6 patch panel, loaded. Make - Dlink 148 Supply, Installation, testing and commissioning of modular patch cables 1m 10/100/1000 Make - AMP/Molex/DC 149 Supply,Installation, testing and commissioning of 24 port POE switch 10/100/1000. Make - Dlink/Netgear 150 Supply, Installation, testing and commissioning of Dual Band Wave Wifi 6 Access Points. Make - Grandstream 151 Supply,Installation, testing and commissioning of cat6 Informatio0n Outlets, non PCB Pyramid type. Make - Dlink/Amp/Molex 152 Supply, Installation, testing and commissioning of Dual Face Plates with clear labeling. Make - Dlink/Amp/Molex 153 Supply, Installation, testing and commissioning of FDB LIU patch panel, loaded. Make - Syrotek 154 Supply, Installation, testing and commissioning of modular patch cables 5mMake - Syrotech/Dlink
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
TenderDetail
Loading tenders