View Bid Results For Numerical Generator Tenders

We found 106 Bid Results related to numerical generator tenders. You can find Contractor details who won numerical generator tenders along with contract details in Bid awards announcements section.

Filters
Stage
79
21
6
Tender Publishing Platform
34
72
State / UT
23
17
14
12
8
7
7
7
5
4
3
3
2
2
2
2
2
2
2
1
1
1
1
1
Contract Value
30
15
45
16
Publish Date
1
0
0
0
0
Sector
13
42
29
9
7
6
3
2
2
2
1
1
1
1
Ownership
6
51
29
12
11
2
1
Within keyword
Active filters:
Showing 1–3 of 106 tenders matching your filters
1.
Power #11494630 Technical Bid
Tender For Biennial Maintenance Contract (Bmc), Form 01.08.26 To 31.07.28, Under Testing Department At Sgtpp-1. Cleaning Of All Control And Protection Related Panels And Equipments. 2. Assistance In Troubleshooting, Rectification, Minor Repairing Of All Type Of Electromagnetic Relays, Static &Numerical Relays. 3. Assistance In Troubleshooting, Rectification, Replacement Or Repairing As Required For Control Circuit, Electrical Measuring Instruments (Meter); Switches; Electrical Transducer, Oti,Wti Transmitter, Annunciator; Control Fuse; Contactor And All Other Associated Equipments/Items Inside The Panels In All Related Area. 4. Assistance In Testing Of Different Relays-Voltage, Current, Frequency, Power, Impedance Etc. 5. Assistance In Testing Of Thermal Over Load Relay, Mcb, Contactors, Timer, Fuse Etc. 6. Assistance In Identification Of Dc Earth Fault At Sgtpp Plant And Rectification Of 220Vdc Earth At The Area Of Testing Department. 7. Assistance In Testing And Calibration Of Meters And Transducer- Voltage, Current, Frequency, Power Factor, Watt,Var, Va Etc. 8. Assistance In Trouble Shooting, Maintenance And Testing Of All Type Of Electronic Modules In All Related Area Under Testing Dept. 9. Assistance In Testing Of All Electrical Installations At Site Or Shop Or Laboratory Such As Generator, Transformer, Circuit Breaker, Ct, Pt, Lightning Arrestor, Motor, Cvt, Reactor, Ngr, Isolator, Control Cable Andpower Cable Etc.Arrangement For Testing Also Be Done By Contractor For Any Location In Sgtpp Area. 10. Assistance In Testing Of Transformer Oil (Bdv, Moisture Content, Tan Delta) Etc. 11. Assistance In Reading Of Static Energy Meter Through Mri Only And Optical Communication Cord By Laptop Also Testing & Calibration Of Different Type Of Energy Meters. 12. Assistance In Testing Of Battery Bank Cells. 13. Assistance To Testing Department Related With Protective Relays, Electrical Instruments, And Different Power Control Panel/Board, System Testing Of All Electrical. Items/Equipment Of 2X300Mw & 2X500 Mw And 1X660Mw Units Of Sgtpp (Plant & Township Areas As Per Direction Of The Controlling Dept.) Like Existing Contract. 14. Shifting Of All Kind Of Testing Instruments And Other Necessary Tools And Tackles From Lab To Site And From Site To Lab Should Be Under The Scope Of Work Of Amc Manpower.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
2.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
3.
Public Administrative Department #11341496 Price Bid
Supply Of Rubber Goods , Rubber Goods , Single, Sterile, Pyrogen Free, Transperent, Leak Proof Pvc Bags. Dual Packing ( Individual & Aluminium ) Eliminating Microbial Contamination On Surface Maintaining The Contents Of The Bag. 350 Ml Capacity With Cpda As Anticoagulant. Ultra Thin Walled 16G Venipuncture Needle As Specified In Iso 1135-3. Soft & Easy To Open Outletport. Labels Must Have Mfg. Date, Expiry Date, Batch No. Manufacturer Must Give Test Reports As Per Ip / Bp / Usp Standard. , Double, Sterile, Pyrogen Free, Transperent, Leak Proof Pvc Bags. Dual Packing ( Individual & Aluminium ) Eliminating Microbial Of The Bag. 350 Ml Capacity With Cpda As Anticoagulant. Ultra Thin Walled Venipuncture Needle As Specified In Iso 1135-3.Soft Twist Off Needle Cover. Vrounded Corners. High Flexible & Kinkresistant Blood Collecting Tube Includesserial Number For Precise Easy Identification. Easy To Break Off Valve. Safe & Easy To Open Outlet Port.Rounded Corners. Highly Transparent Virgin Grade Pvc Material.High Quality Peel Resistant Label.Primarybag Having 350 Ml Capacity And One Satelliet Bag Of 300 Ml. Hould Withstandtemperature S - 70 To + 37 C. Labels Must Have Manufacturing Date, Expiry Date. Batch No. Manufacturer Must Give Test Reports As Per Ip / Bp / Usp Standards. , Triple, Sterile, Pyrogen Free, Transperent, Leak Proof Pvc Bags. Primary Bag Having350ml Capacity And Tow Satelliet Bagof 300Ml Capacity.Dual Packaging ( Individual & Aluminium ) Eliminating Microbial Contamination On Surface Maintaining The Contents Of The Bag. Ultra Thin Walled 16G Venipuncture Needle As Specified In Iso 1135-3. High Flexible & Kink Resistant Blood Collecting Tube Includes Serial Number For Precise Easy Identification.Easy To Break Off Valve.Safe & Easy To Open Outletport.Rounded Corners. Highly Transparent Virgin Grade Pvc Material / Providing Platlet 5 Days Storage Bags. High Quality Peel Resistant Label.Cpda Anticoagulant ( Usp ) . Should With Stand Temperature - 70 To + 37 C. Labels Must Have Mfg. Date, Expiry Date. Batch No.Manufacturer Must Give Test Reports As Per Ip / Bp / Usp Standards. , Blood Transfusion Sets Sterile Non-Toxic Pvc With Soft Transpaent Kink Resistanttube. Latex Tube For Convenient Extra Medication Plastic Soft Transparent Murphy Chamber With Filter Smooth Plastic Spike, Sharp Enough For Easy Piercing Easily Controllable Roller Clamp Needle - 20 / 21G. Leak Proof Double Polythelene Packing. Batch Number Mfg & Expiry Date, Sterlity Date & Method Must Be Mentioned. , Triple, Sterile, Pyrogen Free, Transperent, Leak Proof Pvc Bags. Primary Bag Having 350Ml Capacity And Tow Satelliet Bag Of 300 Ml Capacity. Sagm - 75- 80Ml. Cpd / Sag- Anticoagulant ( Usp ) . Dual Packaging ( Individual & Aluminium ) Eliminatingmicrobial Contamination On Surface Maintainingthe Contents Of The Bag. Ultra Thin Walled 16G Venipuncture Needle Asspecified In Iso 1135-3. Soft Twist Off Needle Cover High Flexible & Kink Resistantblood Collecting Tube Includes Serial Number For Precise Easy Identification.Easy To Break Off Valve. Rounded Corners. Safe & Easy To Open Outlet Port.Highlytransparent Virgin Grade Pvc Material / Providingplatlet 5 Days Storage Bags.High Qualitypeel Resistant Label.Cpda Anticoagulant ( Usp ) . Labels Must Have Manufacturing Date, Expiry Date, Batch No. Should Withstand Temperature -70To + 37 C. Manufacturermust Givetest Reports As Per Ip / Bp / Usp Standards. , Transfer Bag P.V.C Sterile Non-Pyrogenic300 Ml. Capacity With Non-Toxicp.V.C Spike.Labels Must Have The Manufacturing Date, Expiry Date, Batch Number. , Infusion Sets-Sterile Non-Toxic P. V.C. With Soft Transparent Kink Resistant Tube. Latex Tube For Convenient Extra Medication. Plastic Soft Transparent Murphy Chamber. Smooth Plastic Spike, Sharp Enough For Easypiercing.Easily Controllable Roller Clamp Needle - 20 / 21G. Leak Proof Doublepolythelene Packing.Batch Number, Mfg. & Expiry Date, Sterility Date &Method Must Be Mentioned. , Sterile Infusion Set Of Non-Toxic Pvc With Soft Transparent Kink Resistant Tube, Latextube For Convenient Extra Medication Plastic Soft Transprent Murphy Chamber Withbuilt In Air Vent.Filter At The Infusion Endof Tubing. Smooth Plastic Spike.Sharp Enough For Easy Piercing.Easily Controllable Roller Clamp Needle - 20 / 21G. Leakproof Double Polythelene Packing Batch Number, Mfg.&Method Must Be Mentioned. , Catheter No. 3 Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Catheter No. 4 Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Catheter No. 5 Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Catheter No. 6 Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Catheter No.7 Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Catheter No. 8 Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Catheter No.9 Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Catheter No. 10 Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Catheter No.11. Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Catheter No.12 Length 16. Non-Irritant Red Rubber. Proximal Funnel End And Distal Rounded Atraumatic Tip With Side-Hole. , Sterile Foley Catheter 12 F.Two Way Silicon Coated Latex Of High Quality Which Is Non-Irritant To Urethre. Ballon Near The Tip With Bulb Capacity Of 30-50 Ml. , Sterile Foley Catheter 14 F. Two Way Silicon Coated Latex Of Highquality Which Is Non-Irritant To Urethre. Ballon Near The Tip With Bulb Capacityof 30-50 Ml. , Sterile Foley Catheter 16 F. Two Way Silicon Coated Latex Of Highquality Which Is Non-Irritant To Urethre. Ballon Near The Tip With Bulb Capacity Of 30-50 Ml. , Sterile Foley Catheter 18 F. Two Way Silicon Coated Latex Of Highquality Which Is Non-Irritant To Urethre. Ballon Near The Tip With Bulb Capacity Of 30-50 Ml. , Sterile Foley Catheter 20 F. Two Way Silicon Coated Latex Of Highquality Which Is Non-Irritant To Urethre. Ballon Near The Tip With Bulb Capacityof 30-50 Ml. , Sterile Foley Catheter 22 F. Two Way Silicon Coated Latex Of Highquality Which Is Non-Irritant To Urethre. Ballon Near The Tip With Bulb Capacity Of 30-50 Ml. , Sterile Foley Catheter24 F. Two Way Silicon Coated Latex Of High Quality Which Is Non-Irritant To Urethre. Ballon Near The Tip With Bulb Capacity Of 30-50 Ml. , Sterile Foley Catheter 6 F. Two Way Silicon Coated Latex Of High Quality Which Is Non-Irritantto Urethre. Ballon Near The Tip Withbulb Capacity Of 3-5 Ml. ( With Stillate ) Size - 6 , Sterile Foley Catheter 8 F. Two Way Silicon Coated Latex Ofhigh Quality Which Is Non-Irritantto Urethre. Ballon Near The Tip With Bulb Capacity Of 3-5 Ml. ( With Stillate ) Size-8 , Sterile Foley Catheter10 F. Two Way Silicon Coated Latex Ofhigh Quality Which Is Non-Irritantto Urethre. Ballon Near The Tip Withbulb Capacity Of 3-5 Ml. ( With Stillate ) Size-10 , Infant Feeding Tube P.V.C. Non-Toxic Sterile Disposable Pyrogen Free X-Rayopaque Line & Siliconised Nos. 5 At Least Two Holes.Maximum Distance Of 1 Cms Betweenthe First Hole & The Tip Of The Catheter. Packing Should Be Straight.Size- 5- , Infant Feeding Tube P.V.C. Non-Toxic Sterile Disposable Pyrogen Free X-Rayopaque Line & Siliconised Nos. 6 At Least Two Holes.Maximum Distance Of 1 Cms Betweenthe First Hole & The Tip Of The Catheter. Packing Should Be Straight.Size-6 , Infant Feeding Tube P.V.C. Non-Toxic Sterile Disposable Pyrogen Free X-Rayopaque Line & Siliconised Nos. 7 At Least Two Holes.Maximum Distance Of 1 Cms Betweenthe First Hole & The Tip Of The Catheter. Packing Should Be Straight.Size-7 , Infant Feeding Tube P.V.C. Non-Toxic Sterile Disposable Pyrogen Free X-Rayopaque Line & Siliconised Nos. 8 At Least Two Holes.Maximum Distance Of 1 Cms Betweenthe First Hole & The Tip Of The Catheter. Packing Should Be Straight. Size- 8 , Infant Feeding Tube P.V.C. Non-Toxic Sterile Disposable Pyrogen Free X-Rayopaque Line & Siliconised Nos. 9 At Least Two Holes.Maximum Distance Of 1 Cms Between The First Hole & The Tip Of The Catheter. Packing Should Be Straight. Size - 9 , Infant Feeding Tube P.V.C. Non-Toxic Sterile Disposable Pyrogen Free X-Ray Opaque Line & Siliconised Nos. 10 At Least Two Holes. Maximum Distance Of 1 Cms Betweenthe First Hole & The Tip Of The Catheter.Packing Should Be Straight. Size- 10 , Pvc Endo-Tracheal Tube Cuffed, Oral / Nasal, Non-Kinkable, Length 25 Cm To 36 Cm Sterile, Single Use, Thermosensetive Clear Pvcbiocompatiblematerial, Graduated Along Length Murphys Eye Should Have Smooth Tip High Volume - Low Pressure Smoothtapered, Soft Seal Cuff, Black Intimationdepth Maker In The Form Of A Line Or Athin Band, Sensitive Pilot Ballon Wiht Self Sealing Valve, Radio - Opaque Line, 15Mm Universal Connector, Inflatable Pilot Balloon, Having Clear Markings Such As Cuff Resting Diameter, Size Of Tube, Central Channel ( Prevents The Pilot Balloon From Collapsing During Deflation Of The Cuff ) , And Inflation Line ( Aids In Inflating Anddeflating The Cuff ) Size -5.5 Mm I.D. , Pvc Endo-Tracheal Tube Cuffed, Oral / Nasal, Non-Kinkable, Length 25 Cmto 36 Cm Sterile, Single Use, Thermosensetive Clear Pvcbiocompatiblematerial, Graduated Along Length Murphys Eye Should Have Smooth Tip High Volume - Low Pressure Smoothtapered, Soft Seal Cuff, Black Intimationdepth Maker In The Form Of A Line Or Athin Band, Sensitive Pilot Ballon Wiht Self Sealing Valve, Radio - Opaque Line, 15Mm Universal Connector, Inflatable Pilot Balloon, Having Clear Markings Such As Cuff Resting Diameter, Size Of Tube, Central Channel ( Prevents The Pilot Balloon From Collapsing During Deflation Of The Cuff ) , And Inflation Line ( Aids In Inflating Anddeflating The Cuff ) Size- 6.0 Mm I.D. , Pvc Endo-Tracheal Tube Cuffed, Oral / Nasal, Non-Kinkable, Length 25 Cm To 36 Cm Sterile, Single Use, Thermosensetive Clear Pvcbiocompatible Material, Graduated Along Length Murphys Eye Should Have Smooth Tip High Volume - Low Pressure Smoothtapered, Soft Seal Cuff, Black Intimationdepth Maker In The Form Of A Line Or Athin Band, Sensitive Pilot Ballon Wiht Self Sealing Valve, Radio - Opaque Line, 15Mm Universal Connector, Inflatable Pilot Balloon, Having Clear Markings Such As Cuff Resting Diameter, Size Of Tube, Central Channel ( Prevents The Pilot Balloon From Collapsing During Deflation Of The Cuff ) , And Inflation Line ( Aids In Inflating Anddeflating The Cuff ) Size -6.5 Mm I.D. , Pvc Endo-Tracheal Tube Cuffed, Oral / Nasal, Non-Kinkable, Length 25 Cm To 36 Cm Sterile, Single Use, Thermosensetive Clear Pvcbiocompatiblematerial, Graduated Alonglength Murphys Eye Should Have Smooth Tip High Volume - Low Pressure Smoothtapered, Soft Seal Cuff, Black Intimationdepth Maker In The Form Of A Line Or Athin Band, Sensitivepilot Ballon Wiht Self Sealing Valve, Radio - Opaque Line, 15Mm Universal Connector, Inflatable Pilot Balloon, Having Clear Markings Such As Cuff Resting Diameter, Size Of Tube, Central Channel ( Prevents The Pilot Balloon From Collapsing During Deflation Of The Cuff ) , And Inflationline ( Aids In Inflating Anddeflating The Cuff ) Size -7.0 Mm I.D. , Pvc Endo-Tracheal Tube Cuffed, Oral / Nasal, Non-Kinkable, Length 25 Cmto 36 Cm Sterile, Single Use, Thermosensative Clear Pvcbiocompatible Material, Graduated Along Length Murphys Eye Should Have Smooth Tip High Volume - Low Pressure Smoothtapered, Soft Seal Cuff, Black Intimationdepth Maker In The Form Of A Line Or Athin Band, Sensitivepilot Ballon Wiht Self Sealing Valve, Radio - Opaque Line, 15Mm Universal Connector, Inflatable Pilot Balloon, Havingclear Markings Such As Cuff Resting Diameter, Size Of Tube, Central Channel ( Prevents The Pilot Balloon From Collapsing During Deflation Of The Cuff ) , And Inflationline ( Aids In Inflating Anddeflating The Cuff ) Size- 7.5 Mm I.D. , Pvc Endo-Tracheal Tube Cuffed, Oral / Nasal, Non-Kinkable, Length 25 Cmto 36 Cm Sterile, Single Use, Thermosensative Clear Pvcbiocompatible Material, Graduated Alonglength Murphys Eye Should Have Smooth Tip High Volume - Low Pressure Smoothtapered, Soft Seal Cuff, Black Intimationdepth Maker In The Form Of A Line Or Athin Band, Sensitivepilot Ballon Wiht Self Sealing Valve, Radio - Opaque Line, 15Mm Universal Connector, Inflatable Pilot Balloon, Having Clear Markings Such As Cuff Resting Diameter, Size Of Tube, Central Channel ( Prevents The Pilot Balloon From Collapsing During Deflation Of The Cuff ) , And Inflation Line ( Aids In Inflating Anddeflating The Cuff ) Size- 8.0 Mm I.D. , Pvc Endo-Tracheal Tube Cuffed, Oral / Nasal, Non-Kinkable, Length 25 Cmto 36 Cm Sterile, Single Use, Thermosensative Clear Pvc Biocompatible Material, Graduated Along Length Murphys Eye Should Have Smooth Tip High Volume - Low Pressure Smoothtapered, Soft Seal Cuff, Black Intimationdepth Makerin The Form Of A Line Or Athin Band, Sensitive Pilot Ballon Wiht Self Sealing Valve, Radio - Opaque Line, 15Mm Universal Connector, Inflatable Pilot Balloon, Having Clear Markings Such As Cuff Resting Diameter, Size Of Tube, Central Channel ( Prevents The Pilot Balloon From Collapsing During Deflation Of The Cuff ) , And Inflation Line ( Aids In Inflating Anddeflating The Cuff ) Size- 8.5 Mm I.D. , Pvc Endo-Tracheal Tube Cuffed, Oral / Nasal, Non-Kinkable, Length 25 Cm To 36 Cm Sterile, Single Use, Thermosensative Clear Pvcbiocompatible Material, Graduated Alonglength Murphys Eye Should Have Smooth Tip High Volume - Low Pressure Smoothtapered, Soft Seal Cuff, Black Intimationdepth Maker In The Form Of A Line Or Athin Band, Sensitivepilot Ballon Wiht Self Sealing Valve, Radio - Opaque Line, 15Mm Universal Connector, Inflatable Pilot Balloon, Having Clear Markings Such As Cuff Resting Diameter, Size Of Tube, Central Channel ( Prevents The Pilot Balloon From Collapsing During Deflation Of The Cuff ) , And Inflation Line ( Aids In Inflating Anddeflating The Cuff ) Size- 9.0 Mm I.D. , Pvc Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Pvc Biocompatible Material, With Smooth Tip Single Use, Graduated Along The Length From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker In Theform Of A Line Or A Thin Band, Murphys Eye Radio-Opaque Line, 15Mm Universal Connector Size- 2.0 Mm I.D. , Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Length 13 Cm To 30 Cm Sterile, Thermosensitive Clear Pvc Biocompatible Material, With Smooth Tip Single Use, Graduated Along The Length From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker In The Form Of A Line Or A Thin Band, Murphys Eye Radio-Opaque Line, 15Mm Universal Connector Size -2.5 Mm I.D , Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Length 13 Cm To 30 Cm Sterile, Thermosensitive Clear Pvc Biocompatible Material, With Smooth Tip Single Use, Graduated Along Thelength From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker In The Form Of A Line Or A Thin Band, Murphys Eye Radio-Opaque Line, 15Mm Universal Connector Size-3.0 Mm I.D , Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Length 13 Cm To 30 Cm Sterile, Thermosensitive Clear Pvc Biocompatible Material, With Smooth Tip Single Use, Graduated Along Thelength From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker In The Form Of A Line Or A Thin Band, Murphys Eye Radio-Opaque Line, 15Mm Universal Connector Size-3.5 Mm I.D , Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Length 13 Cm To 30 Cm Sterile, Thermosensitive Clear Pvc Biocompatible Material, With Smooth Tip Single Use, Graduated Along The Length From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker In The Form Of A Line Or A Thin Band, Murphys Eyeradio-Opaque Line, 15Mm Universal Connector Size-4.0 Mm I.D , Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Length 14 Cm To 30 Cm Sterile, Thermosensitive Clear Pvc Biocompatible Materialwith Smooth Tip Single Use, Graduated Along The , Length From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker In The Form Of A Line Or A Thin Band, Murphys Eye The Form Of A Line Or A Thin Band, Murphys Eyethe Form Of A Line Or A Thin Band, Murphys Eye Radio-Opaque Line, 15Mm Universal Connector Size-4.5 Mm I.D , Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Length 14 Cm To 30 Cm Sterile, Thermosensitive Clear Pvc Biocompatible Materialthermosensitive Clear Pvc Biocompatible Material, With Smooth Tip Single Use, Graduated Along The Length From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker In The Form Of A Line Or A Thin Band, Murphys Eye Radio-Opaque Line, 15Mm Universal Connector Size-5.0 Mm I.D , Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Length 14 Cm To 30 Cm Sterile, Thermosensitive Clear Pvc Biocompatible Material, With Smooth Tip Single Use, Graduated Along The Length From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker Inthe Form Of A Line Or A Thin Band, Murphys Eye Radio-Opaque Line, 15Mm Universal Connector Size-5.5 Mm I.D , Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Length 14 Cm To 30 Cm Sterile, Thermosensitive Clear Pvc Biocompatible Material, With Smooth Tip Single Use, Graduated Along The Length From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker Inthe Form Of A Line Or A Thin Band, Murphys Eye Radio-Opaque Line, 15Mm Universal Connector Size-6.0 Mm I.D , Endo-Tracheal Tube Plain Oral / Nasal, Non-Kinkable, Length 14 Cm To 30 Cm Sterile, Thermosensitive Clear Pvc Biocompatible Material, With Smooth Tip Single Use, Graduated Along The Length From 3 Cm Onwords At 1 Cm Interval Upto Atleast 10 Cm Black Intimation Depthmaker Inthe Form Of A Line Or A Thin Band, Murphys Eye Radio-Opaque Line, 15Mm Universal Connector Size-6.5 Mm I.D , Microdrip Sets, Sterile Non-Toxic Pvc With Transperent Murphy Drip With Dripper Needle Leak Proof In Double Polyethelene Packing ( Batch No., Mfg Date, Sterility Date & Method Must Be Mentioned ) , Volumetric Microdrip Sterile Non-Toxic P.V.C. With Paediatric Burette Settransparentmurphy Drip With Dripperneedle Leakproof And A Polyethylene Chamber ( Capacity 100Ml With 1Ml Marking ) Packed In Double Polyethylene Packing ( Batch No., Mfg Date, Sterility Date &Method Must Be Mentioned ) , Disposable Non- Sterile Approns Made With Plastic 50 Micron Thickness With Easy To Wear Belt Attachment, Size : 28× 52 , Rubber Sheeting, Water Proof, Resistantto Ageing, Disinfectant, Detergent, Sterilizable ( Mackintosh ) Super Quality Non Creasing Width 90-95 Cms , Nasogastric Tube P.V.C Non-Toxic Sterile Disposable Pyrogen Free With X-Rayopaque Line With Cap Size - 6 - , Nasogastric Tube P.V.C Non-Toxic Steriledisposable Pyrogen Free With X-Rayopaque Line With Cap Size - 8 , Nasogastric Tube P.V.C Non-Toxic Sterile Disposable Pyrogen Free With X-Rayopaque Line With Cap Size- 10 , Nasogastric Tube P.V.C Non-Toxic Sterile Disposable Pyrogen Free With X-Rayopaque Line With Cap Size- 12 , Nasogastric Tube P.V.C Non-Toxic Sterile Disposable Pyrogen Free With X-Ray Opaque Line. With Graduation Mark With Capsize- 14 - , Nasogastric Tube P.V.C Non-Toxic Steriledisposable Pyrogen Free With X-Ray Opaque Line. With Graduation Mark With Cap Size- 16 , Nasogastric Tube P.V.C Non-Toxic Steriledisposable Pyrogen Free With X-Ray Opaque Line. With Graduation Mark With Cap Size-18 , Nasogastric Tube P.V.C Non-Toxic Sterile Disposable Pyrogen Free With X-Ray Opaque Line. With Graduation Mark With Cap Size- , Superior Quality Scalp Vein Setsize-21 ( Gauge ) Non Toxic Pvc Sterile, Pyrogen Free, Sharp & Rust Free Needles Tips For Easy Cannulation Properly Decured Junction Of Needles & Tubing At Butterfly Level Other End Of Tubing Must Have Proper Fitted Stopper & Must Be Properly Fixable I.V. Tubings. Blister Pack. , Superior Quality Scalp Vein Setsize-22 ( Gauge ) Non Toxic Pvc Sterile, Pyrogen Free, Sharp & Rust Free Needles Tips For Easy Cannulation Properly Decured Junction Of Needles & Tubing At Butterfly Level Other End Of Tubing Must Have Proper Fitted Stopper & Must Be Properly Fixable I.V. Tubings. Blister Pack. , Superior Quality Scalp Vein Setsize-23 ( Gauge ) Non Toxic Pvc Sterile, Pyrogen Free, Sharp & Rust Free Needles Tips For Easy Cannulation Properly Decured Junction Of Needles & Tubing At Butterfly Level Other End Of Tubing Must Have Proper Fitted Stopper & Must Be Properly Fixable I.V. Tubings. Blister Pack. , Superior Quality Scalp Vein Set Specially For Paeditric / Neonatial Use.Size-24 ( Gauge ) Non Toxic Pvc Sterile, Pyrogen Free, Sharp & Rust Free Needles Tips For Easy Cannulation Properlydecured Junctionof Needles & Tubing At Butterfly Level Other End Of Tubing Must Have Proper Fitted Stopper & Must Be Properly Fixable I.V. Tubings.Blister Pack. , Superior Quality Scalp Vein Set Specially For Paeditric / Neonatial Use.Size-25 ( Gauge ) Non Toxic Pvc Sterile, Pyrogen Free, Sharp & Rust Free Needles Tips For Easy Cannulation Properly Decured Junctionof Needles & Tubing At Butterfly Level Other End Of Tubing Must Have Proper Fitted Stopper & Must Be Properly Fixable I.V. Tubings.Blister Pack. , Tubing Pressure I.R. Thick Wall With5-6Mm I.D For Suction Apparatus.Non-Collapsible , Adjustable Velcro Strap For Paediatric & Adult Patients Size : 33 Cm. × 2.5 Cm , Urine Bags, 2000Ml Capacity, Sterile Trtansperant Made Up Of Pvc Superiorquality Which Distends Well With Flowof Urine, Leak Proof With Non-Returnablevalve, Drainage Outlet, Supply Kink Resistant Tubing Of 85 To 95 Cm Length. Pyrogen Free, Non-Toxic, Sterile With Graduated Marking. , Chest Drainage Catheter Pvc, Non Toxicpyrogen Free, X-Ray Opaque Line, Sterilised, Disposable Size - 12 - , Chest Drainage Catheter Pvc, Non Toxic Pyrogen Free, X-Ray Opaque Line, Sterilised, Disposable Size -16 , Chest Drainage Catheter Pvc, Non Toxicpyrogen Free, X-Ray Opaque Line, Sterilised, Disposable Size- 20 , Chest Drainage Catheter Pvc, Non Toxicpyrogen Free, X-Ray Opaque Line, Sterilised, Disposable Size - 24 , Chest Drainage Catheter Pvc, Non Toxicpyrogen Free, X-Ray Opaque Line, Sterilised, Disposable Size - 28 , Chest Drainage Catheter Pvc, Non Toxic Pyrogen Free, X-Ray Opaque Line, Sterilised, Disposable Size -32 , Chest Drainage Catheter Pvc, Non Toxic Pyrogen Free, X-Ray Opaque Line, Sterilised, Disposable Size -36 , Water Sealed Drainage System For Interostat Drainage, Sterile, Pyrogen Free, Disposable , Nj Tubes. Radi-Opaque.Spiral Gudewire With Adapter For Injecting The Contrast / Lubricants Flexiblepolyurethane Olive With Two Openings At Distal Tube End Numerical Scale Marking At Every 10 Cm, 12 Ch120 Cm. Length, 15 Ch 100 Cm. , Sterile Personal Protective Kit.It Should Contain The Following Sterile Items In A Tamper Proof Sealed Packet.:1 ) Pe Plastic Adult Full Lengthgown: Quantity : One Piece. Material : Pe Size : Atleast 115 Cm × 132 Cm. Thickness : 110-120 Microns, Sleeves : Round With Velcro Fastner Full Front With Back Open. Facility To Tie At Waist Level. 2 ) Face Mask : Quantity : One Piece.25 Gsm Non-Woven Fabric With Nose Fit. 3 ) Surgeons Cap : Quantity : One Piece.25 Gsm Non-Woven Fabric. Partial Elastic Band For Proper Fit. 4 ) Shoe Cover : Quantity : One Pair, Material : Pe Plastic, More Than 110-120 Micron.Elastic At Ankle Level For Proper Fit5 ) Zero No. Eye Care Spectacles With Side Cover - 1Pc , Quadripal Sterile Pyrogen Free Fransparent Leak Proof Pvc Bag Having 350Ml Capacitywith Cpd As Anticoagulate & Connected Withthe Satellite Bags Of 300Ml Capacity & Onewhich Would Contain 75 To 80Ml Of Sagm Solution As An Additive Solution.The Bag Should Withstand Temperature From 40 C To 37C.The Bag Should Have 16G Leak Proof Ports & Flat Needle Holder Kink Free Tubing With Hot Making For Identification. All Components Used Must Be Comply With Iso / Ce Standards. , Platelet Apheresis Kit For Hymenitica Mbc - 3 ( Reference 995E Extended Storage Platelets / Plasma Affersis Sets ) With Acd Solution 500 Ml Insterile Pyrogen Free Transperent Leakproof Pvc Bags. The Kit Set Sterile. Non Toxic, Pvc Soft Tubing Chamber Or Transparent Plastic With Leak Proof Of ( Batchno, Mfg. Dt. & License, Sterility Dt &Methods Etc. Must Be Mentioned ) The Kit Must Be Comply With Iso / Ce Standard. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes. Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimize, Crushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Of Trauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size -3.5 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes. Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimize Crushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Of Trauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size-4.0 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes. Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimizecrushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Of Trauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size - 4.5 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes. Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimizecrushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Oftrauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size -5.0 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes.Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimize Crushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Oftrauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size - 5.5 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes. Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimizecrushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Oftrauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size-6.0 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes.Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimize Crushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Oftrauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size- 6.5 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes. Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip Andmurphy Eye With Spiral Reinforcement To Minimize Crushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Oftrauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size -7.0 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes. Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimize Crushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Of Trauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size- 7.5 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes. Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimize Crushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Oftrauma It Has An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size - 8.0 Mm I.D. , Pvc, Non Kinkable, Disposable, Cuffed Flexometallic Tubes. Made Of Thermo-Sensitive Clear Pvc With A Smooth Tip And Murphy Eye With Spiral Reinforcement To Minimizecrushing Or Kinking Low Pressure-High Volume Tapered Cuff Made From Velvet Soft Pvc Material, For Minimal Risk Of Trauma It Has An Inflatable Pilot Balloon To Help Indicatecuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And Inflation Line. Size- 8.5 Mm I.D. , Uncuffed North Pole Preform Tube:Softaltraumatic Tip. Should Be Made Up Of Clear, Thermo -Sensitive, Pvc Material To Allow Observation Of The Condensed Exheld Moisture The Design Should ) Ensure Free Access To The Maxilla & Mandealbeduring Surgery.It Should Maintain The Facial Symmetry While Providing Stable Fixation Of Tube.It Shouldhave Clear Markings On The At The Levgel Of The Vocal Chords & External Nares To Assist In Correct Placement. A Black Intubation Depth Marker Locatedat The Level Of Vocal Cords Assist In Accurate Placement Ofthe Trachealtube Within The Tracheal 1Cm Graduations On The Side Of The Tube To Identify The Distance From The Tip Murphy Eye On The Side Opposite To The Bevel There Should Be Radio-Opaque Line On The Tube To Confirm Position Of The Tube.Should Confirm To The International Stds &Safety Features Size- Tubes3.5 , Uncuffed North Pole Preform Tube:Softaltraumatic Tip. Should Be Made Up Of Clear, Thermo -Sensitive, Pvc Material To Allow Observation Of The Condensed Exheld Moisture The Design Should ) Ensure Free Access To The Maxilla & Mandealbe During Surgery.It Should Maintain The Facial Symmetry While Providing Stable Fixation Of Tube.It Shouldhave Clear Markings On The At The Level Of The Vocal Chords & External Nares To Assist In Correct Placement. A Black Intubation Depth Marker Locatedat The Levgel Of Vocal Cords Assist In Accurate Placement Ofthe Trachealtube Within The Tracheal 1Cm Graduations On The Side Of The Tube To Identify The Distance From The Tip Murphy Eye On The Side Opposite To The Bevel There Should Be Radio-Opaque Line On The Tube To Confirm Position Of The Tube.Should Confirm To The International Stds &Safety Features Size -Tubes4.0 , Uncuffed North Pole Preform Tube:Softaltraumatic Tip. Should Be Made Up Of Clear, Thermo -Sensitive, Pvc Material To Allow Observation Of The Condensed Exheld Moisture The Design Should ) Ensure Free Access To The Maxilla & Mandealbe During Surgery.It Should Maintain The Facial Symmetry Whileproviding Stable Fixation Of Tube.It Shouldhave Clear Markings On The At The Levgel Of The Vocal Chords & External Nares To Assist In Correct Placement. A Black Intubation Depth Marker Locatedat The Level Of Vocal Cords Assist In Accurate Placement Ofthe Trachealtube Within The Tracheal 1Cm Graduations On The Side Of The Tube To Identify The Distance From The Tip Murphy Eye On The Side Opposite To The Bevel There Should Be Radio-Opaque Line On The Tube To Confirm Position Of The Tube.Should Confirm To The International Stds &Safety Features Size- Tubes4.5 , Uncuffed North Pole Preform Tube:Softaltraumatic Tip. Should Be Made Up Of Clear, Thermo -Sensitive, Pvc Material To Allow Observation Of The Condensed Exheld Moisture The Design Should ) Ensure Free Access To The Maxilla & Mandealbe During Surgery.It Should Maintain The Facial Symmetry While Providing Stable Fixation Of Tube.It Shouldhave Clear Markings On The At The Level Of The Vocal Chords & External Nares To Assist In Correct Placement. A Black Intubation Depth Marker Locatedat The Levgel Of Vocal Cords Assist In Accurate Placement Ofthe Trachealtube Within The The Distance From The Tip Murphy Eye On The Side Opposite To The Bevel There Should Be Radio-Opaque Line On The Tube To Confirm Position Of The Tube.Should Confirm To Theinternational Stds &Safety Featuressize - Tubes 5.0 , Uncuffed North Pole Preform Tube:Softaltraumatic Tip. Should Be Made Up Of Clear, Thermo -Sensitive, Pvc Material To Allow Observation Of The Condensed Exheld Moisture The Design Should ) Ensure Free Access To The Maxilla & Mandealbeduring Surgery.It Should Maintain The Facial Symmetry While Providing Stable Fixation Of Tube.It Shouldhave Clear Markings On The At The Level Of The Vocal Chords & External Nares To Assist In Correct Placement. A Black Intubation Depth Marker Locatedat The Levgel Of Vocal Cords Assist In Accurate Placement Ofthe Trachealtube Within The Tracheal 1Cm Graduations On The Side Of The Tube To Identify The Distance From The Tip Murphy Eye On The Side Opposite To The Bevel There Should Be Radio-Opaque Line On The Tube To Confirm Position Of The Tube.Should Confirm To The International Stds &Safety Features Size - Tubes 5.5 , Cuffed North Pole Preform Tube: Soft Atraumatic Tip Should Be Made Up Of Clear, Thermo - Sensitive, High Quality Ivory Pvc Material To Allow Observation Of The Condensed Exhaled Moisture The Design Should Insure Free Accessto The Maxilla & Mandeable During Surgery.It Should Maintain Thefacial Synmetry While Providing Stable Fixation Of Tube.It Shouldhave Clear Markings On The Tube At The Level Of The Vocal Cords & External Nerves To Assist In Correct Placement. A Black Intubation Depth Marker Located 3Cm Proximal To The Cuffe.This Assist In Accurate Placement Of The Tracheal Tube Within The Trachea 1Cm Graduation On Side Of The Tubeto Identify The Distance From The Bevel.Cuffeshould Be Profile & Made From Soft Pvcmaterial, Minimising The Risk Of Trauma, Cuffe Should Be High Volume, Low Pressure Type To Minimise Lateral Pressure On Tracheal Wall. The Resting Diameter Of The Cuffe Should Be Large Ensuring Effective Seal In Trachea, Even When Small Tracheal Cuffes Are Used. Thereshould Be Radio- Opaque Line On The Tube To Confirm Position Of The Tube. The Preformed Bend Should Have Markings Forcutting Tube Shorter Postoperatively For Easier Suctioningshould Have An Inflatable Pilot Balloon To Help Indicate Cuffpressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And A Blue Inflation Line. The Tube Confirm To The International Standards & Safety Features .Size-Tubes 5.5 , Cuffed North Pole Preform Tube: Soft Atraumatic Tip Should Be Made Up Of Clear, Thermo - Sensitive, High Quality Ivory Pvc Material To Allow Observation Of The Condensed Exhaled Moisture The Design Should Insure Free Accessto The Maxilla& Mandeable During Surgery.It Should Maintain Thefacial Synmetry While Providing Stable Fixation Of Tube.It Should Have Clear Markings On The Tube At The Level Of The Vocal Cords & External Nerves To Assist In Correct Placement. A Black Intubation Depth Marker Located 3Cm Proximal To The Cuffe.This Assist In Accurate Placement Of The Tracheal Tube Within The Trachea 1Cm Graduation On Side Of The Tube To Identify The Distance From The Bevel.Cuffeshould Be Profile & Made From Soft Pvcmaterial, Minimising The Risk Of Trauma, Cuffe Should Be High Volume, Low Pressure Typeto Minimise Lateral Pressure On Tracheal Wall. The Resting Diameter Of The Cuffe Should Be Large Ensuring Effective Seal In Trachea, Even When Small Tracheal Cuffes Are Used. There Should Be Radio- Opaque Line On The Tube To Confirm Position Of The Tube. The Preformed Bend Should Have Markings Forcutting Tube Shorter Postoperatively For Easier Suctioning Should Have An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Restingdiameter, With A Spring-Loaded One-Way Valve, And A Blue Inflation Line. The Tube Confirm To The International Standards & Safety Features Size -Tubes 6.0 , Cuffed North Pole Preform Tube: Soft Atraumatic Tip Should Be Made Up Of Clear, Thermo - Sensitive, High Quality Ivory Pvc Material To Allow Observation Of The Condensed Exhaled Moisture The Design Should Insure Free Accessto The Maxilla & Mandeable During Surgery.It Should Maintain Thefacial Synmetry While Providing Stable Fixation Of Tube.It Should Have Clear Markings On The Tube At The Level Of The Vocal Cords & External Nerves To Assist In Correct Placement. A Black Intubation Depth Marker Located 3Cm Proximal To The Cuffe.This Assist In Accurate Placement Of The Tracheal Tube Within The Trachea 1Cm Graduation On Side Of The Tube To Identify The Distance From The Bevel.Cuffeshould Be Profile & Made From Soft Pvcmaterial, Minimising The Risk Of Trauma, Cuffe Should Be High Volume, Low Pressure Type To Minimise Lateral Pressure On Tracheal Wall. The Restingdiameter Of The Cuffe Should Be Large Ensuring Effective Seal In Trachea, Even When Small Tracheal Cuffes Are Used. There Should Be Radio- Opaque Line On The Tube To Confirm Position Of The Tube. The Preformed Bend Should Have Markings Forcutting Tube Shorter Postoperatively For Easier Suctioning Should Have An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Restingdiameter, With A Spring-Loaded One-Way Valve, And A Blue Inflation Line. The Tube Confirm To The Internationalstandards & Safety Features Size - Tubes 6.5 , Cuffed North Pole Preform Tube: Soft Atraumatic Tip Should Be Made Up Of Clear, Thermo - Sensitive, High Quality Ivory Pvc Material To Allow Observation Of The Condensed Exhaled Moisture The Design Should Insure Free Accessto The Maxilla& Mandeable During Surgery.It Should Maintain Thefacial Synmetry While Providing Stable Fixation Of Tube.It Should Have Clear Markings On The Tube At The Level Of The Vocal Cords & External Nerves To Assist In Correct Placement. A Black Intubation Depth Marker Located 3Cm Proximal To The Cuffe.This Assist In Accurate Placement Of The Tracheal Tube Within The Trachea 1Cm Graduation On Side Of The Tubeto Identify The Distance From The Bevel.Cuffeshould Be Profile & Made From Soft Pvcmaterial, Minimising The Risk Of Trauma, Cuffe Should Be High Volume, Low Pressure Typeto Minimise Lateral Pressure On Tracheal Wall. The Resting Diameter Of The Cuffe Should Be Large Ensuring Effective Seal In Trachea, Even When Small Tracheal Cuffes Are Used. Thereshould Be Radio- Opaque Line On The Tube To Confirm Position Of The Tube. The Preformed Bend Should Have Markings Forcutting Tube Shorter Postoperatively For Easier Suctioning Should Have An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And A Blue Inflation Line. The Tube Confirm To The International Standards & Safety Featuressize -Tubes 7.0 , Cuffed North Pole Preform Tube: Soft Atraumatic Tip Should Be Made Up Of Clear, Thermo - Sensitive, High Quality Ivory Pvc Material To Allow Observation Of The Condensed Exhaled Moisture The Design Should Insure Free Accessto The Maxilla & Mandeable During Surgery.It Should Maintain Thefacial Synmetry While Providing Stable Fixation Of Tube.It Should Have Clear Markings On The Tube At The Level Of The Vocal Cords & External Nerves To Assist In Correct Placement. A Black Intubation Depth Marker Located 3Cm Proximal To The Cuffe.This Assist In Accurate Placement Of The Tracheal Tube Within The Trachea 1Cm Graduation On Side Of The Tube To Identify The Distance From The Bevel.Cuffeshould Be Profile & Made From Soft Pvcmaterial, Minimising The Risk Of Trauma, Cuffe Should Be High Volume, Low Pressure Type To Minimise Lateral Pressure On Tracheal Wall. The Resting Diameter Of The Cuffe Should Be Large Ensuring Effective Seal In Trachea, Even When Small Tracheal Cuffes Are Used. There Should Be Radio- Opaque Line On The Tube To Confirm Position Of The Tube. The Preformed Bend Should Have Markings Forcutting Tube Shorter Postoperatively For Easier Suctioning Should Have An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Restingdiameter, With A Spring-Loaded One-Way Valve, And A Blue Inflation Line. The Tube Confirm To The International Standards & Safety Features Size - Tubes 7.5 , Cuffed North Pole Preform Tube: Soft Atraumatic Tip Should Be Made Up Of Clear, Thermo - Sensitive, High Quality Ivory Pvc Material To Allow Observation Of The Condensed Exhaled Moisture The Design Should Insure Free Accessto The Maxilla & Mandeable During Surgery.It Should Maintain Thefacial Synmetry While Providing Stable Fixation Of Tube.It Should Have Clear Markings On The Tube At The Level Of The Vocal Cords & External Nerves To Assist In Correct Placement. A Black Intubation Depth Marker Located 3Cm Proximal To The Cuffe.This Assist In Accurate Placement Of The Trachealtube Within The Trachea 1Cm Graduation On Side Of The Tube To Identify The Distance From The Bevel.Cuffeshould Be Profile & Made From Soft Pvcmaterial, Minimising The Risk Of Trauma, Cuffe Should Be High Volume, Low Pressure Type To Minimise Lateral Pressure On Tracheal Wall. The Resting Diameter Of The Cuffe Should Be Large Ensuring Effective Seal In Trachea, Even When Small Tracheal Cuffes Are Used. Thereshould Be Radio- Opaque Line On The Tube To Confirm Position Of The Tube. The Preformed Bend Should Have Markings Forcutting Tube Shorter Postoperatively For Easier Suctioningshould Have An Inflatable Pilot Balloon To Help Indicate Cuffpressure, Having Clear Markings Such As Cuff Restingdiameter, With A Spring-Loaded One-Way Valve, And A Blue Inflation Line. The Tube Confirm To The Internationalstandards & Safety Features Size -Tubes 8.0 , Cuffed North Pole Preform Tube: Soft Atraumatic Tip Should Be Made Up Of Clear, Thermo - Sensitive, High Quality Ivory Pvc Material To Allow Observation Of The Condensed Exhaled Moisture The Design Should Insure Free Accessto The Maxilla & Mandeable During Surgery.It Should Maintain Thefacial Synmetry While Providing Stable Fixation Of Tube.It Should Have Clear Markings On The Tube At The Level Of The Vocal Cords & External Nerves To Assist In Correct Placement.A Black Intubation Depth Marker Located 3Cm Proximal To The Cuffe.This Assist In Accurate Placement Of The Tracheal Tube Within The Trachea 1Cm Graduation On Side Of The Tube To Identify The Distance From The Bevel.Cuffeshould Be Profile & Made From Soft Pvcmaterial, Minimising The Riskof Trauma, Cuffe Should Be High Volume, Low Pressure Type To Minimise Lateral Pressure On Tracheal Wall. The Resting Diameter Of The Cuffe Should Be Large Ensuring Effective Seal In Trachea, Even When Small Tracheal Cuffes Are Used. There Should Be Radio- Opaque Line On The Tube To Confirm Position Of The Tube. The Preformed Bend Should Have Markings Forcutting Tube Shorter Postoperatively For Easier Suctioning Should Have An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And A Blueinflation Line. The Tube Confirm To The Internationalstandards & Safety Features Size - Tubes 8.5 , Cuffed North Pole Preform Tube: Soft Atraumatic Tip Should Be Made Up Of Clear, Thermo - Sensitive, High Quality Ivory Pvc Material To Allow Observation Of The Condensed Exhaled Moisture The Design Should Insure Free Accessto The Maxilla & Mandeable During Surgery.It Should Maintain Thefacial Synmetry While Providing Stable Fixation Of Tube.It Shouldhave Clear Markings On The Tube At The Level Of The Vocal Cords & External Nerves To Assist In Correct Placement. A Black Intubation Depth Marker Located 3Cm Proximal To Thecuffe.This Assist In Accurate Placement Of The Tracheal Tube Within The Trachea 1Cm Graduation On Side Of The Tube To Identify The Distance From The Bevel.Cuffeshould Be Profile & Made From Soft Pvcmaterial, Minimising The Risk Of Trauma, Cuffe Should Be High Volume, Low Pressure Type To Minimise Lateral Pressure On Tracheal Wall. The Resting Diameter Of The Cuffe Should Be Large Ensuring Effective Seal In Trachea, Even When Small Tracheal Cuffes Are Used. There Should Be Radio- Opaque Line On The Tube To Confirm Position Of The Tube. The Preformed Bend Should Have Markings For Cutting Tube Shorter Postoperatively For Easier Suctioning Should Have An Inflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And A Blueinflation Line. The Tube Confirm To The International Standards & Safety Features Size - Tubes 9.0 , Uncuffed South Polar Preform Tubes :Soft Atraumatic Tip Uniform Internal Diameter, South Limb Covered So As To Avoid Any Pressure On A Chin & Lower Tip.The Design Should Ensure Free Access To Maxilla, Upperlip, Pallet & Nose While Maintainingsymmetry Should Be Made Up Of Clear, Thermo - Sensitive, Pvc Material To Allow Observation Of The Condensed Exhold Moisture 1Cm Graduation On The Side Of The Tube Toidentify The Distance From The Tip. A Black Intubation Depth Marker Located At The Level Of The Vocal Cort Assist In Accurate Placement Of The Tracheal Tube Within The Trachea.Inflation Line Take Off Point Should Lie Outside Themouth Bevel Of The Tube Shouldface Laterally.Murphyeye Should Be Smooth & Should Be On The Side Opposite Tothe Bevel. There Should Be Radio- Opaque Line On The Tube To Confirm Position Of Thetube & Should Confirm To The Internationalstandards & Safety Features. Size-Tubes 3.5 Size- Tubes 4.5 , Uncuffed South Polar Preform Tubes :Soft Atraumatic Tip Uniform Internal Diameter, South Limb Covered So As To Avoid Any Pressure On A Chin & Lower Tip.The Design Should Ensure Free Access To Maxilla, Upperlip, Pallet & Nose While Maintainingsymmetry Should Be Made Up Of Clear, Thermo - Sensitive, Pvc Material To Allow Observation Of The Condensed Exhold Moisture 1Cm Graduation On The Side Of The Tube Toidentify The Distance From The Tip. A Black Intubation Depth Marker Located At The Level Of The Vocal Cort Assist In Accurate Placement Of The Tracheal Tube Within The Trachea. Inflation Line Take Off Point Should Lie Outside The Mouth Bevel Of The Tube Shouldface Laterally.Murphy Eye Should Be Smooth & Should Be On The Side Opposite To The Bevel. There Should Be Radio- Opaque Line On The Tube To Confirm Position Of Thetube & Should Confirm To The Internationalstandards & Safety Features. , Uncuffed South Polar Preform Tubes :Soft Atraumatic Tip Uniform Internal Diameter, South Limb Covered So As To Avoid Any Pressure On A Chin & Lower Tip.The Design Should Ensure Free Access To Maxilla, Upperlip, Pallet & Nose While Maintainingsymmetry Should Be Made Up Of Clear, Thermo - Sensitive, Pvc Material To Allow Observation Of The Condensed Exhold Moisture 1Cm Graduation On The Side Of The Tube Toidentify The Distance From The Tip. A Black Intubation Depth Marker Located At The Level Of The Vocal Cort Assist In Accurate Placement Of The Tracheal Tube Within The Trachea.Inflation Line Take Off Point Should Lie Outside The Mouth Bevel Of The Tube Shouldface Laterally.Murphy Eye Should Be Smooth & Should Be On The Side Opposite To The Bevel. There Should Be Radio- Opaque Line On The Tube To Confirm Position Of Thetube & Should Confirm To The Internationalstandards & Safety Features. Size- Tubes 5.5 , Uncuffed South Polar Preform Tubes :Soft Atraumatic Tip Uniform Internal Diameter, South Limb Covered So As Toavoid Any Pressure On A Chin & Lower Tip.The Design Should Ensure Free Access To Maxilla, Upperlip, Pallet & Nose While Maintainingsymmetry Should Be Made Up Of Clear, Thermo - Sensitive, Pvc Material To Allow Observation Of The Condensed Exhold Moisture 1Cm Graduation On The Side Of The Tube Toidentify The Distance From The Tip. A Black Intubation Depth Markerlocated At The Level Of The Vocal Cort Assist In Accurate Placement Of The Tracheal Tube Within The Trachea.Inflation Line Take Off Point Should Lie Outside The Mouth Bevel Of The Tube Shouldface Laterally.Murphyc Eye Should Be Smooth & Should Be On The Side Opposite To The Bevel. There Should Be Radio- Opaque Line On The Tube To Confirm Position Of Thetube & Should Confirm To The Internationalstandards & Safety Features. Size- Tubes 8.0 , Cuffed South Polar Preform Tubes :Softatraumatic Tip Uniform Internal Diameter, South Limb Covered So As To Avoid Anypressure On A Chin & Lower Tip. Thedesign Should Ensure Free Access To Maxilla, Upperlip, Pallet & Nose While Maintainingsymmetry Should Be Made Up Of Clear, Thermo -Sensitive, Pvc Material To Allowobservation Of The Condensed Exhald Moisture1cmgraduation On The Side Of The Tubeto Identify Thedistance From The Tipa Black Intubation Depth Markerlocated At The Level Of The Vocal Cords Assist Inaccurateplacement Of The Tracheal Tubewithin The Trachea. The Cuff Should Beprofile & Made Form Soft Pvc Material, Mnimising The Risk Of Trauma. Cuffshould Be High Volume, Low Pressure Typeto Minimise Lateral Pressure On Tracheal Wall.The Resting Diameter Of The Cuff Shouldbe Large Ensuring Effective Seal In Trachea. Inflation Line Take Off Point Should Lie Outside The Mouth Bevel Of The Tube Should Face Laterally. Murphy Eye Should Be Smooth & Shouldbe On The Side Apposite To The Bevel.There Should Be Radio Opague Line On The To Of Confirm Position Of The Tube Should Confirm To The International Standard And Safetyfeatures. Clear Size Identification On The Southlimbinflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With Aspring-Loaded One-Way Valve, And A Blue Inflation Line.Size- 5.5 , Cuffed South Polar Preform Tubes : Softatraumatic Tip Uniform Internal Diameter, South Limb Covered So As To Avoid Anypressure On A Chin & Lower Tip. Thedesign Should Ensure Free Access To Maxilla, Upper Lip, Pallet & Nose While Maintainingsymmetry Should Be Made Up Of Clear, Thermo -Sensitive, Pvc Material To Allowobservation Of The Condensed Exhald Moisture1cm Graduation On The Side Of The Tubeto Identify The Distance From The Tipa Black Intubation Depth Marker Located At The Level Of The Vocal Cords Assist Inaccurate Placement Of The Tracheal Tubewithin The Trachea. The Cuff Should Beprofile & Made Form Soft Pvc Material, Mnimising The Risk Of Trauma. Cuffshould Be High Volume, Low Pressure Typeto Minimise Lateral Pressure On Tracheal Wall.The Resting Diameter Of The Cuff Shouldbe Large Ensuring Effective Seal In Trachea. Inflation Line Takeoff Point Should Lie Outside The Mouth Bevel Of The Tubeshould Face Laterally. Murphy Eye Should Be Smooth & Should Be On The Side Apposite To The Bevel.There Should Be Radio Opague Line On The To Of Confirm Position Of The Tubeshould Confirm To The International Standard And Safety Features. Clear Size Identification On The Southlimbinflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And A Blue Inflation Line. Size- 6.5 , Cuffed South Polar Preform Tubes : Softatraumatic Tip Uniform Internal Diameter, South Limb Covered So As To Avoid Anypressure On A Chin & Lower Tip. Thedesign Should Ensure Free Access To Maxilla, Upper Lip, Pallet & Nose While Maintainingsymmetry Should Be Made Up Of Clear, Thermo -Sensitive, Pvc Material To Allowobservation Of The Condensed Exhald Moisture1cm Graduation On The Side Of The Tubeto Identify The Distance From The Tipa Black Intubation Depth Marker Located At The Level Of The Vocal Cords Assist Inaccurate Placement Of The Tracheal Tubewithin The Trachea. The Cuff Should Beprofile & Made Form Soft Pvc Material, Mnimising The Risk Of Trauma. Cuffshould Be High Volume, Low Pressure Typeto Minimise Lateral Pressure On Tracheal Wall.The Resting Diameter Of The Cuff Shouldbe Large Ensuring Effective Seal In Trachea. Inflation Line Take Off Point Should Lie Outside The Mouth Bevel Of The Tubeshould Face Laterally. Murphy Eye Should Be Smooth & Should Be On The Side Apposite To The Bevel.There Should Beradio Opague Line On The To Of Confirm Position Of The Tube Should Confirm To The International Standard And Safetyfeatures. Clear Size Identification On The Southlimbinflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And A Blue Inflation Line. Size- 7.5 , Cuffed South Polar Preform Tubes : Softatraumatic Tip Uniform Internal Diameter, South Limb Covered So As To Avoid Anypressure On A Chin & Lower Tip. Thedesign Should Ensure Free Access To Maxilla, Upperlip, Pallet & Nose While Maintainingsymmetry Should Be Made Up Of Clear, Thermo -Sensitive, Pvc Material To Allowobservation Of The Condensed Exhald Moisture1cm Graduation On The Side Of The Tubeto Identify The Distance From The Tipa Black Intubation Depth Marker Located At The Level Of The Vocal Cords Assist Inaccurate Placement Of The Tracheal Tubewithin The Trachea. Thecuff Should Beprofile & Made Form Soft Pvc Material, Mnimising The Risk Of Trauma. Cuffshould Be High Volume, Low Pressure Typeto Minimise Lateral Pressure On Tracheal Wall.The Resting Diameter Of The Cuff Shouldbe Large Ensuring Effective Seal In Trachea. Inflation Line Take Off Point Should Lie Outside The Mouth Bevel Of The Tube Should Face Laterally. Murphy Eye Should Be Smooth & Should Be On The Side Apposite To The Bevel.There Should Be Radio Opague Line On The To Of Confirm Position Of The Tube Should Confirm To The International Standard And Safetyfeatures. Clear Size Identification On The South Limbinflatable Pilot Balloon To Help Indicate Cuff Pressure, Having Clear Markings Such As Cuff Resting Diameter, With A Spring-Loaded One-Way Valve, And A Blue Inflation Line. Size - 8.0 , Quadruple, Sterile, Pyrogen Free, Transparent, Leak Proof Pvc Bag Prinary Bag Having350 Ml Capacity And 3Satellite Bagtwo Satellite Bag Of 300Ml Capacity One Of Which Will Have 75-80Ml Sagm Solution And One Of50ml Capacity.Dual Packaging ( Individual And Alluminum ) Limiting Contamination On Surface Marinating Contentof The Bag. Ultra Thin Walled 16G Venepuncture Needle As Specified In Iso 1135-3. High Flaxible Hang The Bags Ivertedly In The Extractor Without Giving Much Pressure In The Instrument. Needle Protector Should Be With Inner Soft Pvc Material To Ensure Hermetic Closure Of The Hub And Outer One Is Made Of Polypropulene To Ensure Rigidity Of The Cap And Maintain The Integrity Of The Needle. High Quality Peel Resistant Labels Must Have Mfg. Date, Exp. Date, Batch No. Manufacturer Must Give The Test Reports As Per Ip / Bp / Usp Standards. And Kink Resistantblood Collecting Tubes Includes Serial No. For Precise Easy Identification. Easy To Break Of Valve. Safe And Easy Toopen Outlet Port. Rounded Corners. Highly Transparentvirgin Grade Pvc Material Providing Platelets 5Days Storage Bags. Cpda Anticoagulant ( Usp ) Should Wihtsatand Temperature-80 Degree Celcius To + 37 Degree Celcius. The Donor Tube Length Wiht 123+ / -2Cm And Tubes Of Satelliteshould Have Length Of 30+ / -2Cms, Upto Y-Connection ( With Minimum Of 4 Hot Markings ) And From The Y-Connection To The Satellite Bag The Length Required Should Be 30+ / -2Cms ( With Minimumof 4 Hot Markings ) . The Hot Markings / Numbering Shall Be Identical In In Donor As Well As Satellite Bag Tubes. It Should Be In A Position Route Through The Automatic Component Extractor. There Shouldbe 2 Handholes On The Top Of Seal Of Themother Bag Buffy Bag To Hang In The Component Extractor.The Length Between 2 Holes Should Be 2.1Cm+ / -0.1Cm. There Should Be A Slit In The Bottom Of All Bags To , Catheter Mount , Disposable Face Mask 3Ply With Lace , Cord Clamp , Sterile Connecting Device Wafers 1. Wafers Should Be Packed In A Cassettefor Easy Installation In Sterile Connecting Device. 2. Each Cassette Should Have Minimum 70 Wafers.3. It Should Be Compatible For Welding Of Blood Bags Tubes Or Apheresis Set Modification. 4. The Product Code Should Be Capitalsc* W017. 5. Wafers Shold Have Length Of 34.3Mm, Width 12.71Mm & Thickness Of 0.28Mm. 6. Internal Resistance ( Silver Coated ) In Therange Of 8O To 12O 7. Wafer Input Voltage Should Be 12V Dc. 8. Time To Reach 320 Dc Should Be 8Seconds To 12 Seconds.9. Insulation Resistance At 500 V Should Be 5 M? , Disposable N-95* Respirators Available In Sizes: Small, Medium, Large Cup / Pouch Shaped Strong Band To Secure To Face *Filtration Efficiency Of 95% Or More For Non Oil Based Praticles 0.3 Micron Or Above , Disposable Surgical #N-95* Respirators Available In Sizes: Small, Medium, Large Cup / Pouch Shaped Strong Band To Secure To Face #Fluid Resistance At 160 Mm Hg *Filtration Efficiency Of 95% Or More For Non Oilbased Praticles 0.3 Micron Or Above , Neonatal Cpap Delivery Set: Consisting Of: 1. Disposable Neonatal Heated Wire Breathing Circuit With Inspiratory Limb Heating, Autofeed Chamber, Compatible With Mr 850, Mr 730 Heater Base And Compatible With All Brands Of Nasal Cpap Masks 2 ) Nasal Cpap Masks Of Assorted Sizes ( Xs, S, M, Xl ) Withappropriate Sizes Bonnets. 3. Bubble Cpap Generator. , Tracheostomy Tube, Plain Single Use, Sterile Size No. 3.5 1. Should Be Made Of Thermosensitivesiliconised Pvc. 2. Should Have A Soft, Semi Directionalflexible Flange. 3. Should Have A Radio Opaque Blue Line On The Tube. 4. Should Have A Rounded Distal Edge. 5. Should Be Uncuffed. 6. Should Have An 15Mm Connector Integrated On The Tracheostomy Tube. 7. Should Have Ce Approval. , Tracheostomy Tube, Plain Single Use, Sterile Size No. 4.0 1. Should Be Made Of Thermosensitivesiliconised Pvc. 2. Should Have A Soft, Semi Directionalflexible Flange. 3. Should Have A Radio Opaque Blue Line On The Tube. 4. Should Have A Rounded Distal Edge. 5. Should Be Uncuffed. 6. Should Have An 15Mm Connector Integrated On The Tracheostomy Tube. 7. Should Have Ce Approval. , Tracheostomy Tube, Plain Single Use, Sterile Size No. 4.5 1. Should Be Made Of Thermosensitivesiliconised Pvc. 2. Should Have A Soft, Semi Directionalflexible Flange. 3. Should Have A Radio Opaque Blue Line On The Tube. 4. Should Have A Rounded Distal Edge. 5. Should Be Uncuffed. 6. Should Have An 15Mm Connector Integrated On The Tracheostomy Tube. 7. Should Have Ce Approval. , Tracheostomy Tube, Plain Single Use, Sterile Size No. 5.0 1. Should Be Made Of Thermosensitivesiliconised Pvc. 2. Should Have A Soft, Semi Directionalflexible Flange. 3. Should Have A Radio Opaque Blue Line On The Tube. 4. Should Have A Rounded Distal Edge. 5. Should Be Uncuffed. 6. Should Have An 15Mm Connector Integrated On The Tracheostomy Tube. 7. Should Have Ce Approval. , Tracheostomy Tube, Cuffed Single Use, Sterile Size No. 6 1. Should Be Made Of Thermosensitive Pvc. 2. Should Have A High Volume - Low Pressure, Velvet Soft Cuff. 3 Should Have Clear Marking On The Pilot Balloon That Provide Informationon I.D. Of The Tube And Cuff Restingdiameter. 4. Should Have A Clear Flexible Flange. 5. Should Have A Tapered Distal Tip.6. Should Have A Hollow Obturator With Rounded Tip For Insertion Over A Guide Wire. 7. Should Have An 15Mm Connector Integrated On The Tracheostomy Tube. 8. Should Have An Option Of Inserting An Inner Cannula.9. Should Have Ce Approval. , Tracheostomy Tube, Cuffed Single Use, Sterile Size No. 7 1. Should Be Made Of Thermosensitive Pvc. 2. Should Have A High Volume - Low Pressure, Velvet Soft Cuff. 3 Should Have Clear Marking On The Pilot Balloon That Provide Informationon I.D. Of The Tube And Cuff Restingdiameter. 4. Should Have A Clear Flexible Flange. 5. Should Have A Tapered Distal Tip.6. Should Have A Hollow Obturator With Rounded Tip For Insertion Over A Guide Wire. 7. Should Have An 15Mm Connector Integrated On The Tracheostomy Tube. 8. Should Have An Option Of Inserting An Inner Cannula.9. Should Have Ce Approval. , Tracheostomy Tube Single Use, Cuffed, Sterile Size No. 7.5 1. Should Be Made Of Thermosensitive Pvc. 2. Should Have A High Volume - Low Pressure, Velvet Soft Cuff. 3 Should Have Clear Marking On The Pilot Balloon That Provide Informationon I.D. Of The Tube And Cuff Restingdiameter. 4. Should Have A Clear Flexible Flange. 5. Should Have A Tapered Distal Tip.6. Should Have A Hollow Obturator With Rounded Tip For Insertion Over A Guide Wire. 7. Should Have An 15Mm Connector Integrated On The Tracheostomy Tube. 8. Should Have An Option Of Inserting An Inner Cannula.9. Should Have Ce Approval. , Tracheostomy Tube Single Use, Cuffed, Sterile Size No. 8 1. Should Be Made Of Thermosensitive Pvc. 2. Should Have A High Volume - Low Pressure, Velvet Soft Cuff. 3 Should Have Clear Marking On The Pilot Balloon That Provide Informationon I.D. Of The Tube And Cuff Restingdiameter. 4. Should Have A Clear Flexible Flange. 5. Should Have A Tapered Distal Tip.6. Should Have A Hollow Obturator With Rounded Tip For Insertion Over A Guide Wire. 7. Should Have An 15Mm Connector Integrated On The Tracheostomy Tube. 8. Should Have An Option Of Inserting An Inner Cannula.9. Should Have Ce Approval. , Tracheostomy Tube, Cuffed Single Use, Sterilesize No. 8.5 1. Should Be Made Of Thermosensitive Pvc. 2. Should Have A High Volume - Low Pressure, Velvet Soft Cuff. 3 Should Have Clear Marking On The Pilot Balloon That Provide Informationon I.D. Of The Tube And Cuff Restingdiameter. 4. Should Have A Clear Flexible Flange. 5. Should Have A Tapered Distal Tip.6. Should Have A Hollow Obturator With Rounded Tip For Insertion Over A Guide Wire. 7. Should Have An 15Mm Connector Integrated On The Tracheostomy Tube. 8. Should Have An Option Of Inserting An Inner Cannula.9. Should Have Ce Approval. , Airway 2 , Airway 3 , Airway 4 , Nebulisation Chambers , Suction Catheter Disposable No. 6 , Suction Catheter Disposable No. 8 , Suction Catheter Disposable No. 9 , Suction Catheter Disposable No. 10 , Suction Catheter Disposable No. 12 , Suction Catheter Disposable No. 14 , Nasal Prongs / Nasal Oxygen Cannula, Single Use Paediatric Use , Nasal Prongs / Nasal Oxygen Cannula, Single Use Neonatal Size No. 5 , Oxygen Mask ( Single Use, Disposable ) Paediatric Size , Oxygen Mask ( Venturi ) Adult Oxygen Mask Clear, Non-Toxic Pvc Material With 6 Color Coded Diluters For Adjusting Fio2, Adjustable Nose Clip. Anti-Crush Tubing. , Oxygen Mask With Reservoir Bag Adult High Concentrationdisposable Oxygen Maskmade Of Non-Toxic, Clear Pvc Material With Reservoir Bag ( 1000 Cc ) Non-Rebreathing Maskwith Anti-Crush 7 Ft. Tubingwith Adjustable Nose Clip. , Bacterio-Viral Filter With Humidifier ( Disposable ) Connection 22 M / 15F - 22F / 15 M Filter Withhydrophilic 0.3 Micron, Efficiency>99%, Sterilizedby Ionizing Radiation , Hollow Fibre Dialysermembrane : Synthetic : Poly Sulfone / Poly Ether Sulfone / Polyamide Surface Area : 0.9 Sq. Mt. , Hollow Fibre Dialysermembrane : Synthetic : Poly Sulfone / Poly Ether Sulfone / Polyamide Surface Area : 1.3 Sq. Mt. , Blood Line Tubing Type Universal Arterialvenous Line Pump Segmentvenous Chamber. , Silicone Band 2.5*0.7Mm ( 240 ) Silicone , Silicone Tyre 2.5*7Mm ( 279 ) Silicone , Silicone Intubation Set ( Bicanalicular ) 23G Needle-11Cm*0.6Mm Diam Inner Diam-0.30Mm Outer Diam-0.64Mm , Monocanalicular Stent Length-40Mmdiam-0.64Mm Silicone Rod , Frontalis Sling Needle-6.3Cm*92 Omicron Diamlength Of Rod -40Cmlength Of Sleeve-7Mmsilicone , Orbital Floor Implants 6*6 Inches Single Sheet Silicone , Air Injection Tubing Silicone , I / A Cannula And Tubing 23G Curved Shaft With 0.3Mm Top Aspirating Port 21G Irrigation Silicone Tube Stainless Steel Hub And Shaft , Silicon Oil Injection Cannula Set20g And 23G Silicone , Theraputic Plasma Exchange Kits For Haemonetics Aphaeresis Machine ( Reference981e-00 Tpe Set { 125 Ml Lathem } ) With 2 Acdsolution Each 500Ml In Sterile Pyrogen Freetransparent Leakproof Bags. The Kit Set Sterile .Non Toxic, Pvc Soft Tubing Chamber Or Transparent Plastic With Leak Proof Of ( Batch No, Mfg Date & License, Sterlitydate And Methods Etc Must Be Mentioned ) . The Kitsmust Be Comply With Iso / Ce Standard. , Theraputic Plasma Exchange Kits For Haemonetics Aphaeresis Machine ( Reference981e-00 Tpe Set { 225 Ml Lathem } ) With 2 Acd Solution Each 500Ml In Sterile Pyrogen Freetransparent Leakproof Bags. The Kit Set Sterile .Non Toxic, Pvc Soft Tubing Chamber Ortransparent Plastic With Leak Proof Of ( Batch No, Mfg Date & License, Sterlitydate And Methods Etc Must Be Mentioned ) . The Kitsmust Be Comply With Iso / Ce Standard. , Pvc Endotracheal Tube Cuffed, Oral / Nasal 5.0 Mm Id Made Of Thermosensitive Clear Pvc With Smoothtip, Murphy Eye And Radioopaque Blue Line, Clear Size Identification On South Limb, Intubation Length ( Tip To Incisor Teethidentification Mark ) Confirms To Cut-To-Length Norms, Low Presure High Volume Cuff Made From Pvc Material, Intubation Depth Marker Present And Clear Depth Markings, A Blue 15Mm Connector, Single Use Available In Sterile Package, Latex Free, Ce Certified And Fda Approved , Oxygen Mask ( Single Use ) Adult Size Light Weight Design, Soft Edge For Patient Comfort, Nose Clip For Nose Bridge Adjustment Andbetter Fit, Pull Through Adjustable Elastic Head Band, 2 Meter Tubing , Nasal Prongs / Nasal Oxygen Cannula For Adults U Shaped Moulding With Limbs Which Is Insertedinto Nostril, 2 Meter Tubing , Disposable Suction Linear Bag Primary ( Green ) With Inbuild Solidify Agent 2 Liter Capacity. , Disposable Suction Linear Bag Final ( Red ) With Flow Stopper & Inbuild Solidify Agent 2 Liter Capacity. , Bmw Black Bag Large. Size: 30X34 Thickness 90 Microns, Quality- Double Sealing, Chlorine Free, Leak Proof And Compliant With Govt. Of Maharashtra Notification Of Plastics, Printed Label: Printing As Per Cpcb Guidelines, Name Of Hospital, Chlorine Free Bags, Area And Date Of Generation, Not For Biomedical Waste, Mfg Date, Expiry Date / Use Before Date, Batch Number. , Bmw Red Baglarge. Size - 30X34” ( Weight Bearing 16-20 Kgs ) . Material:Compostable Plastic And Complies With Most Recent Standard For Compostable Plastic 17088 And Version / Year As Applicable, Chlorine Free, Should Not Be Made Of Reused Plastic, Autoclavable; Should Withstand Autoclaving At 121 ° C For 60 Minutes , Bmw Yellow Bag Large Size - 30X34” ( Weight Bearing 16-20 Kgs ) . ( Should Be Capable Of Bearing Weight < 10Kgs ) . Material: Compostable Plastic And Complies With The Most Recent Standard For Compostable Plastic 17088 And Version / Year As Applicable, Chlorine Free, Should Not Be Made Of Reused Plastic , Bmw Black Bag Medium Size - 29X32”, Thickness 90 Microns, Quality- Double Sealing, Chlorine Free, Leak Proof And Compliant With Govt. Of Maharashtra Notification Of Plastics, Printed Label: Printing As Per Cpcb Guidelines, Name Of Hospital, Chlorine Free Bags, Area And Date Of Generation, Not For Biomedical Waste, Mfg Date, Expiry Date / Use Before Date, Batch Number. , Bmw Red Bagmedium. Size - 29X32” ( Weight Bearing 10-15 Kgs ) . Material:Compostable Plastic And Complies With Most Recent Standard For Compostable Plastic 17088 And Version / Year As Applicable, Chlorine Free, Should Not Be Made Of Reused Plastic, Autoclavable; Should Withstand Autoclaving At 121 ° C For 60 Minutes , Arterial Line Transducers , Bmw Yellow Bag Medium Size - 29X32” ( Weight Bearing 10-15 Kgs ) . ( Should Be Capable Of Bearing Weight < 10Kgs ) . Material: Compostable Plastic And Complies With The Most Recent Standard For Compostable Plastic 17088 And Version / Year As Applicable, Chlorine Free, Should Not Be Made Of Reused Plastic , Bmw Black Bagsmallsize - 25X29”, Thickness 90 Microns, Quality- Double Sealing, Chlorine Free, Leak Proof And Compliant With Govt. Of Maharashtra Notification Of Plastics, Printed Label: Printing As Per Cpcb Guidelines, Name Of Hospital, Chlorine Free Bags, Area And Date Of Generation, Not For Biomedical Waste, Mfg Date, Expiry Date / Use Before Date, Batch Number. , Bmw Red Bag Small.Size - 25X29” ( Should Be Capable Of Bearing Weight < 10Kgs ) . Material:Compostable Plastic And Complies With Most Recent Standard For Compostable Plastic 17088 And Version / Year As Applicable, Chlorine Free, Should Not Be Made Of Reused Plastic, Autoclavable; Should Withstand Autoclaving At 121 ° C For 60 Minutes , Bmw Yellow Bag Smallsize - 25X29” ( Should Be Capable Of Bearing Weight < 10Kgs ) . Material: Compostable Plastic And Complies With The Most Recent Standard For Compostable Plastic 17088 And Version / Year As Applicable, Chlorine Free, Should Not Be Made Of Reused Plastic , Disposable Ventilator Tubing Set Adult Made Of Plastic, Tube Length At Least 2 Meters, Comprising Of Adult Size Corrugated Tubings , Y Piece , Angle Connector, Water Trap Chamber , Adult Cuff Bp Apparatus, Clinically Accurate Measurements, 4 Different Button For Easy Operation, Who Indicator, Wide Cuff For Both Regular And Large Arms, Oscillometric Method For Better Accuracy, Quiet And Low Noise Inflation, Low Battery Indication , Lma Protector Size 3 Second Generation Airway With Dual Gastricaccess, Soft Silicone Elongatedcuff For Effective First And Second Seal Anatomically Shaped Eliptical Airway, Should Have Fixation Tab And Integral Bite Block And Cuff Pressure Indicator , Lma Protector Size 4 Second Generation Airway With Dual Gastricaccess, Soft Silicone Elongatedcuff For Effective First And Second Seal Anatomically Shaped Eliptical Airway, Should Have Fixation Tab And Integral Bite Block And Cuff Pressure Indicator , Paediatric Short Breathing Circuits- 1.8Meter Single Use Pediatric Expandable Anaesthesia Circuit With Bifurcated Wye With 1 L Breathing Bag , Hfnc Cannula Infant Size ( 00, 01 ) Pressure Of Gas -Air / Oxygen @0.3-0.4 Mpa; Blender Alarm Noise >50Db With Humidifier Temperature Monitoring With Heater Wire , Dvt Stockings , Disposable Breathing Circuits , Disposable Ventilator Tubing Set Pediatrics Made Of Plastic, Tube Length At Least 2 Meters, Comprising Of Adult Size Corrugated Tubings , Y Piece , Angle Connector, Water Trap Chamber , Nebulisation Kit Paediatric- Complete With Nebulisation Chamber, T Piece And Tubing. *This Item Is Being Added As Only The Chamber Is Available In The Schedule ) Material Pvc , Nebulizer Volume 6-12Cc With 1 Meter Extension Tube , Sharp Waste Disposal Cans Size: 20 L Printed With Biohazard Symbol Colour: Blue Material : Plastic, Properties : Leak Proof , Puncture Proof And Tamper Proof ( It Should Not Be Possible To Remove Items That Have Been Dropped In The Can ) A Marked Line Along The Circumference Of The Sharp Can To Indicate The Level That Should Be Considered As Full , Bp Apparatus Stand Model Mercurial Type, Adjustable In Height With Adult, Pediatric And Infantbp Cuffs, Measurement Range 0-290Mmhg , Supraglottic Airway 4 Second Generation Airway With Gastricaccess, Soft Elongated Cuff For Effective First And Second Seal Anatomically Shaped Eliptical Airway, Should Have Fixation Tab And Integral Bite Block , Disposable Laryngeal Mask Airway 2Nd Generation, With Gastric Suction Portwith Soft Gel, Non-Inflatable Cuff Size 4.0 , Disposable Laryngeal Mask Airway 2Nd Generation, With Gastric Suction Portwith Soft Gel, Non-Inflatable Cuff Size 3.0 , Airvo Kit ( All Sizes ) ( Optiflow Nasal Interface Having Soft Flexible Prongs, Heated Breathing Tubes Having Dual Spiral Heater Wires And Unique Integrated Temperature Sensors With Adjustable Temperature And Flow Settings , Material- Polyvinyl Chloride , 3 Way Stop Cock With Extension Tube 100Cm Sterile, Disposable, Pvc Material, Kink Resistant , Nebulisation Kit- Complete With Nebulisation Chamber, T Piece And Tubing. *This Item Is Being Added As Only The Chamber Is Available In The Schedule ) , Adult Breathing Circuits , Cautery Pad - 5L X 3W, Made Of A Plastic Base Material That Is Covered With A Metal Film That Serves As The Actual Electrode Surface 9 Foot Wire, Insulated Conductive Silicon Rubber, Adult Type , Heat And Moisture Exchange And Breathing System Filters Rigid Filter Housing With 2 Standard Connection Port 22M And 15F, Material- Hygroscopic Filter Coated Wityh Calcium Chloride And Lithium Chloride Polypropylene , Supraglottic Airway 3Second Generation Airway With Gastricaccess, Soft Elongated Cuff For Effective First And Second Seal Anatomically Shaped Eliptical Airway, Should Have Fixation Tab And Integral Bite Block , Absorbent Sheet 60X90cm , 8Mm Thickness, Large Size , High Absorbancy, Leak Proof Backing , Incentive Spirometer 3 Ball Lungs Exerciser, Adult Size , Short Sheath 5F Vascular Introducer Sheath , Stoma Bag 2 Piece, Flexible Pe Coupling System. Good Anti-Leakage Function. Cureguard Adhesive Skin Barrier , Lma Protector Size 5 Second Generation Airway With Dual Gastricaccess, Soft Silicone Elongatedcuff For Effective First And Second Seal Anatomically Shaped Eliptical Airway, Should Have Fixation Tab And Integral Bite Block And Cuff Pressure Indicator , Short Sheath 8F Vascular Introducer Sheath , Abdominal Binder Large Size, 90-100 Cm, Material: Polyester+Rubber+Nylon With Velcro Closure , Infant Cuff Bp Apparatus : Display Type- Manual, Material - Nylon, Band Size-6 To 11 Cm , Adult Long Breathing Circuits , Abdominal Binder Medium Size, Material: Polyester+Rubber+Nylon With Velcro Closure , Hfnc Cannula Adult , Adult Diaper Medium Size, Tape Style, 42 Inch, Cotton, Unisex , Abdominal Binder Extra Large Size, Material: Polyester+Rubber+Nylon With Velcro Closure , Arterial Line Cannula 20G 3.8Cm , Paediatric Long Breathing Circuits - 6 Meter Single Use Pediatric Expandable Anaesthesia Circuit With Bifurcated Wye With 1 L Breathing Bag , Air Bed, Material: Pvc ; Size 78” By 34” ; Alternating Pressure Mattress , Nasal Cpap Neonatal Bonnets.Single Use, Colour Codedbiocompatible Microfibre, Soft Elastic Material With Attached Fixation Bands, Velcro Straps For Prongs And Masks. Size Xs ( Whitecolour ) , Stoma Bag With Wafersingle Piece, Odor Proof Multi Layer Pouch Material , Disposable Laryngeal Mask Airway 2Nd Generation, With Gastric Suction Portwith Soft Gel, Non-Inflatable Cuff Size 2.5 , Arterial Line Cannula 20G 3.6 Cm , Paediatric Cuff Bp Apparatus : Display Type-Manual, Material - Nylon, Band Size-17 To 22Cm , Disposable Laryngeal Mask Airway 2Nd Generation, With Gastric Suction Portwith Soft Gel, Non-Inflatable Cuff Size 2.0 , Short Sheath 4F Vascular Introducer Sheath , Disposable Laryngeal Mask Airway 2Nd Generation, With Gastric Suction Portwith Soft Gel, Non-Inflatable Cuff Size 1.5 , Sharp Waste Disposal Cans Size: 5 L Printed With Biohazard Symbol Colour: Blue Material : Plastic, Properties : Leak Proof , Puncture Proof And Tamper Proof ( It Should Not Be Possible To Remove Items That Have Been Dropped In The Can ) A Marked Line Along The Circumference Of The Sharp Can To Indicate The Level That Should Be Considered As Full , Mlscopy Tubes 5.0 Mm Latex Free Medical Grade Plastic Tube, Adult Length, High Volume, Low Pressure Cuff, Kink Resistant , Mlscopy Tubes 5.5 Mm Latex Free Medical Grade Plastic Tube, Adult Length, High Volume, Low Pressure Cuff, Kink Resistant , Intubation Guiding Bougie ( Paediatric ) 3 Mm Diameter, 35Cm Length, Tip Angulated At 30 Degree, Gum Elastuc Bougie , Microcuff Tubes Size 4.0 Pediatric Sized Tubes With High Volume Low Pressure, Microthin Polyurathane, Short Cylindrical Cuff. Latex Free , Manual In Line Closed Suction Catheter For Endotracheal Tubes ( 12F, 14F ) , Pvc Tubing, With Thumb And Finger Tip Contr , Mlscopy Tubes 6.0Mmlatex Free Medical Grade Plastic Tube, Adult Length, High Volume, Low Pressure Cuff, Kink Resistant , Dual Heated Infant Breathing Circuit Kit With Mr290 Autofeed Chamber ( Flow> 4L / Min ) , Material- Polyvinyl Chloride , Intubation Guiding Bougie ( Adult ) 4Mm Diameter, 70 Cm Length, Tip Angulated At 30 Degree, Gum Elastuc Bougie , Air Mattress With Air Pump And Pressure Setting, Dimensions : 200X90x7 Cm Tube Length 200Cm , Weight Bearing Capacity 135 Kg, Material Polyvinyl Chloride, Air Flow 3L / Min , Manual In Line Closed Suction Catheter For Tracheostomy Tubes ( 12F, 14F ) , Pvc Tubing, With Thumb And Finger Tip Contr , Head Ring Base Size 200 -220 Mm*45Mm-50Mmmade Of Silicon Material , Microcuff Tubes Size 5.0 Pediatric Sized Tubes With High Volume Low Pressure, Microthin Polyurathane, Short Cylindrical Cuff. Latex Free , Dual Heated Neonatal Breathiing Circuit Kit With Evaqua Technology And Mr290 Autofeed Chamber Withheating Wire For Series Ventilators , Microcuff Tubes Size 4.5 Pediatric Sized Tubes With High Volume Low Pressure, Microthin Polyurathane, Short Cylindrical Cuff. Latex Free , Sharp Waste Disposal Cans Size: 2 L Printed With Biohazard Symbol Colour: Blue Material : Plastic, Properties : Leak Proof , Puncture Proof And Tamper Proof ( It Should Not Be Possible To Remove Items That Have Been Dropped In The Can ) A Marked Line Along The Circumference Of The Sharp Can To Indicate The Level That Should Be Considered As Full , Microcuff Tubes Size 3.5 Pediatric Sized Tubes With High Volume Low Pressure, Microthin Polyurathane, Short Cylindrical Cuff. Latex Free , Universal Gel Pad -Size Around 500Mm*300Mm*10-15Mm , Nasophayngeal Airway: A Disposable, Flexible Soft Pvc, Beveled Tip Tube Which Goes Through The Nose And Ends At The Base Of The Tongue Size - 6.5 , Head Ring Base Size 140-150Mm*35-40Mmmade Of Silicon Material , Abdominal Binder Xxl Size Material: Polyester+Rubber+Nylon With Velcro Closure , Microcuff Tubes Size 5.5 Pediatric Sized Tubes With High Volume Low Pressure, Microthin Polyurathane, Short Cylindrical Cuff. Latex Free , Universal Precaution Kit, The Kit Includes Full Body Cover, Face Helmet, Hand Gloves, Shoes Cover, Face Mask , Cuff Pressure Monitor Analog System Hand Held Endotracheal Cuff Pressure Monitor, Gauge Range Of 0-120 Cm Of H2o , Supraglottic Airway 2 Second Generation Airway With Gastricaccess, Soft Elongated Cuff For Effective First And Second Seal Anatomically Shaped Eliptical Airway, Should Have Fixation Tab And Integral Bite Block , Arterial Access Catheter For Pressure Monitoring Paediatric Sterile 20 Gauge Catheter 8Cm Length With Guidewire Made From Polyethylene Material With Needle For Insertion Of 20 Guage , Cautery Pencil - Disposable, Standard Hand Control Push Button Electro Surgical Cautery Pencil 3-Pin With 150Mm Blade & 3 Meter Cable, Monopolar , Disposable Ventilator Tubing Set ;Pediatrics: 1.5 Meter , Single Use, Dual Limb Tubings , Connector Material-Poly Propylene , Tube Material- Ldpe+Eva , Manual Resuscitation Bags Adult Silicone, Self Inflating, Autoclavable, 2000Ml Capacity With Nonrebreathing Valve At Patient End And Port For Oxygen At Other End , Nasophayngeal Airway: A Disposable, Flexible Soft Pvc, Beveled Tip Tube Which Goes Through The Nose And Ends At The Base Of The Tongue Size - 6 , Introducer Needle 18G Bevelled Shape Stainless Steel Puncture Needle. , Disposable Laryngeal Mask Airway 2Nd Generation, With Gastric Suction Portwith Soft Gel, Non-Inflatable Cuff Size 1.0 , Head Ring Base Size 90-95Mm*20-25Mmmade Of Silicon Material , Manual Resuscitation Bags Infant :Material- Latex Free Silicon Material; 100% Autoclavable, Capacity: 250Ml And 500Ml
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 39
Maharashtra View Result →
5.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
7.
Agriculture #10759745 Price Bid
1 Supply, installation, testingand commissioning of 30 KVA, 3 Phase, 415 V AC, 50 Hz, 0.8 PF (lag), Silent DG Set (CPCB IV+) comprising of Engine coupled with alternatormounted on a common base frame. The DG set shall comprising of following; 1) The Engine (confirming to IS 10002) developing minimum 42 BHP at 1500 RPM, liquid cooled with radiator and fan, Turbo charged, powered by minimum four (4) strokes, multi cylinder, shall be automatic electric starting by 12 V DC starter motor system (battery capactity 90 Ah) and fitted with Electronic Governor (confirming to IS 10000) 2) DG set is capable of delivering an output of 10% in excess of rated KVA for a period of 1 hr in any period of 12 hrs continous running.3) The alternator (confirming to IS 4722) shall be brushless type, self-excited and self-regulated. The alternator must be provided with IP 23 protection with class-H insulation.Alternator efficiency at 100% load (0.8 pf) is not less than 88% and maximum voltage dip at full load (0.8 pf lag) is less than 20%.4) Instrument Control Panel shall be furnished for the engine and shall be comprising of Push Button, Water temperature gauge, Hour meter with RPM indicator, Lube oil pressure gauge.5) DG set complete with Acoustic enclosure shall be made of Pre-treated and Powder coated CRCA Sheet with vermin proof. Along with Residential Silencer and noise level less than or equal to 75 db at a distance of 1 m from of Acoustic enclosure (confirming toIS 8528- 10). DG accoustic enclosure shall have inbuilt fuel tank of minimum 70 litres capacity and fuel piping (between fuel tank and diesel engine), valves, level indications, oil filter and allstandard accessories. MS pipes, heavy class of suitable dia shall be used for fuel piping . Glass window on acoustic enclosure in front of the control panel and emergency stop switch outside the acoustic enclosure.6) DG set should be provided with remote monitoring system to share real time genset information and can be acceseed via mobile device or desktop.7) AVM Pads as per engine manufacturer standard shall be provided for DG set.8) Standard set of tools consisting of a set of 3 spanners, one screw driver, one standard plier and one nose plier of appropriate size shall be provided.9) Type Approval Certicate (as per CPCB IV norms) for the specified rating of the Power Generator from any of the designated agency authorized by CPCB,Type test report for Alternator latest to conform the specications. Company warranty certificate for 2 years on complete DG set shall be provided. 2 Fabrication, Supplying, Installation, Testing & Commissioning of AMF control panel. The Panel shall be free standing, floor mounted, metal clad cubicle type in construction, to form a compact assembly in dust / damp and vermin proof type, equivalent to IP-53. The thickness of sheet steel members shall not be less than 1.6 mm for cold rolled steel. AMF panel shall be complete with all accessories such as changeover Contactors/MCCBs having sufficient rating, AMF relays etc. for auto changeover of supply from Grid to DG set and vice-versa. Electrical Protections shall be provided through Numerical relays. Required CTs & PTs for metering and protection shall be included. All necessary control and supervisory equipment for the automatic operation of the set shall be included in the panel. Suitable rating of MCCB with over-load and short-circuit protection shall be mounted in the Control Panel for the isolation of loads. MCBs shall be provided for the isolation / protection of control circuit. AMF panel shall be equipped with meters displaying the parameters like Voltage,current , frequency, speed, KVA, KW, Power Factor, fuel Level, Engine running hour counter,Lube Oil Pressure and Engine temperature, etc. 3 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 4 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 5 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 6 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 7 Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. 8 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 9 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 10 All kinds of soil 11 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 13 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 14 Centering and shuttering including strutting, propping etc. and removal of form for 15 Foundations, footings, bases of columns, etc. for mass concrete. 16 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. 17 Thermo-Mechanically Treated bars of grade Fe-500D or more. 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 19 Cement mortar 1:4 (1 cement : 4 coarse sand) 20 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 21 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 22 6 mm cement plaster of mix : 23 1:3 (1 cement : 3 fine sand) 24 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 25 Hot finished welded type tubes. 26 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of total thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 27 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. 28 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 29 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 30 Supplying ofXLPE Armoured cable with aluminium conductor of 1.1 KV grade confirming to IS:7098 (Part- I) 1988 with up to date ammendments of the following sizeas required. 31 3.5 x 50 sq. mm 32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 33 3½ X 50 sq. mm (35mm) 34 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 35 Above 35 sq. mm and upto 95 sq. mm 36 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 37 Above 35 sq. mm and upto 95 sq. mm 38 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 39 Above 35 sq. mm and upto 95 sq. mm 40 Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 7
8.
Educational and Research Institute #10617957 Price Bid
Supply Of Advanced Communication System Lab Equipments - 2 Ask Modulation And Demodulation Kit N Carrier Signal Generator - Sine 10Khz N Data Generator - 4 Different Data Inputs N Power Supply Inbuilt ( ±5V / 500Ma ) N Closed Wood / Ms Box N Input Ac230v N 3 Frequency Shift Keying Trainer Kit [ Fsk ] N ( Transmitter & Receiver ) N Clock Generator - 10Khz N Data Generator - 4 Different Data’S N Fsk Modulation Using Ic 7400 N Fsk Demodulation Included N Power Supply Inbuilt N Closed Wood / Ms Box ( ±5V / 500Ma ) N Input Ac230v N 4 Phase Shift Keying Trainer Kit [ Psk ] N ( Modulation & Demodulation ) N Carrier Signal Generator - Sine 10Khz N Data Generator - Using Decade Counter 7490 N Power Supply Inbuilt ( ±5V / 500Ma ) N Closed Wood / Ms Box N Input Ac230v N 5 Tdm Trainer Kit N Digital Time Division Multiplexing And De-Multiplexing N 8 Bit Data Generator N Clock And Address Generator N 8:1 Multiplexer N 1:8 De-Multiplexer N Power Supply Inbuilt ( ±12V / 500Ma, +5V / 500Ma ) N Input Ac230v N Closed Wood / Ms Box N 6 Fiber Optic Analog Link [ Transmitter & Receiver ] Nfiber Optic Cable - 1 Meter - 1 No. N Fiber Optic Cable - 3 Meter - 1 No. N Signal Source Inbuilt N Power Supply Inbuilt N Closed Wood / Ms Box N Input Ac230v N 7 Fiber Optic Digital Link [ Transmitter & Receiver ] N N Built In Clock Generator N Fiber Optic Cable 1 Meter - 1No. N Power Supply Inbuilt N Closed Wood / Ms Box N Input Ac230v N 8 Measure The Bending Loss And Propagation Loss In Fiber Optics N N Transmitter : One Fiber Optics Led Having Peak Wave Length Of N Emission 660 Nm N Receiver : One Fiber Optic Photo Detector N Drivers : Analog N Ac Amplifier : 1 No. N Analog Band Width : 350 Khz N Digital Band Width : 2.5 Mhz N Function Generator : 1Khz & 2 Khz Sine Wave ( Amplitude Adj ) N Interconnection : 2Mm Banana Socket N Fiber Optics Cable : Connector Type Standard Sma ( Sub Miniature Assembly ) Duly Polished N Fiber At Both The Ends For Numerical Aperture N Measurement Cable : Step Indexed Multimode Pmma Plastic Cable N Fiber Length : 3M With Sma Connectors N Power Supply : 230V±10%, 50 Hz N N 9 Manchester Encoder & Decoder Trainer Kit N ( Line Coding & Decoding Kit ) N N +5V Dc Power Supply N Delta Clock Generator N Delta Generator With 8 Bit Selective Switch N Channel Encoder N Channel Decoder N Patch Cards N Wood / Ms Box ( Closed Type ) N 10 Measure The Numerical Aperture Of Optical Fiber N N Transmitter : One Fiber Optics Led Having Peak Wave Length Of N Emission 660 Nm N Receiver : One Fiber Optic Photo Detector N Drivers : Analog N Ac Amplifier : 1 No. N Analog Band Width : 350 Khz N Digital Band Width : 2.5 Mhz N Function Generator : 1Khz & 2 Khz Sine Wave ( Amplitude Adj ) N Interconnection : 2Mm Banana Socket N Fiber Optics Cable : Connector Type Standard Sma ( Sub Miniature Assembly ) Duly Polished N Fiber At Both The Ends For Numerical Aperture N Measurement Cable : Step Indexed Multimode Pmma Plastic Cable N Fiber Length : 1M With Najt Connectors N Power Supply : 230V±10%, 50 Hz N N 11 Voice Link Using Optical Fiber With Telephone Hand Set N N Transmitter : One Fiber Optics Led Having Peak Wave Length Of N Emission 660 Nm N Receiver : One Fiber Optic Photo Detector N Drivers : Analog & Digital N Ac Amplifier : 1 No. N Filter : 2 Nos.4Th Order Butterworth 3.4Khz Cut-Off Frequency N Analog Band Width : 350 Khz N Function Generator : 1Khz Variable Amplitude & Frequency Sine Wave ( Amplitude Adj ) N Voice Link : Fo Voice Link Using Two Nos. Of Telephone Handset N Interconnection : 2Mm Banana Socket N Fiber Optics Cable : Connector Type Standard Sma ( Sub Miniature Assembly ) Duly Polished N Fiber At Both The Ends For Numerical Aperture N Fiber Cable : Step Indexed Multimode Pmma Plastic Cable N : 1Mtr With Sma Connectors N Power Supply : 230V±10%, 50 Hz N N 12 Dth System 13 Construct A Led Circuit To Find The Photo Diode Characteristics 14 Digital Oscilloscope - 50Mhz Model: Smo 502
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
9.
Water Resources and Irrigation #10558790 Price Bid
Supplying, Installation, Testing & Commissioning of Mix-flow type Electric Pump Sets & equipments with all accessories etc. including development of Substation for New Pump House at Jahangirpuri drain near Gopalpur Regulator RD-1135m.- 1 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 55 KW/75 HP , 6 Pole , 980 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 35x35 Size Pump set having 1400 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 2 Supplying, installation, testing and commissioning of totally enclosed fan cooled squirrel cage 3-Phase induction motor confirming to protection IP 55 Horizontal foot mounted suitable for open duct on 415+/- 10%, 3-Phase 50HZ +/- 5% AC supply with Ambient 50°C class F insulation 75 KW/100 HP , 8 Pole , 740 RPM with performance standard confirming to IS 12615 coupled with suitable size standard Coupling to MF 40x45 Size Pump set having 2000 m3/hr discharge at 10 mtr head and CI casing, SS Impeller, SS shaft, SS shaft sleeve with Gland packed shaft sealing complete with all standard accessories mounted on frame of suitable size with complete grouting or mounted on suitable cushyfoot vibration mounting pad completed etc. as required at site(Motor Make:- Kirloskar/Crompton/ A.B.B./ Siemens) (Pump Make:- Kirloskar/ Wilo/ Flowmore/KSB) 3 Supplying , installation, testing and commissioning of Sound Proof Steel enclosure Water Cooled Engine coupled with Alternator 320KVA/256 KW silent DG Generator set including Base frame, Radiator/Heat Exchanger/Fuel Tank/ Control Panel /AMF panel, fuel piping foundation, all interconnections, loop Earthing, Silencer completed all as per CPWD/CPCB norms with standard accessories etc. as required.(Make:- Crompton Greaves/ Kirloskar/ Cummins or as approved by Engineer-in-charge) 4 M.S. Pipes:-Manufacturing , Supplying, erection & commissioning of Mild Steel ERW, (Electric Resistance welded) Pipe fabricated/manufactured out of Fe410 Mild Steel Grade 330 as per IS: 3589 of reputed & approved make , including painting with epoxy paint inside and outside surface with two coats of anticorrosive paint of approved brand and manufacture : all conforming to relevant IS codes: complete in all respect and with upto date amendments in relevant IS codes:(Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge)1200mm nominal dia pipes of 12mm thick complete as required at site. 5 350mm nominal dia pipes of 8mm thick complete as required at site. 6 400mm nominal dia pipes of 8mm thick complete as required at site. 7 450mm nominal dia pipes of 8mm thick complete as required at site. 8 MS Flanges:- Manufacturing, Supplying, fixing & welding of following sizes M.S. Flanges etc complete. as requiredat site. 1200mm dia. & 25mm thickness. 9 350mm dia. & 20mm thickness. 10 400mm dia. & 20mm thickness. 11 450mm dia. & 20mm thickness. 12 MS Bends:-Manufacturing, Supplying, fixing & welding of following sizes M.S. Bends etc. complete. as requiredat site. 1200mm dia. 13 350mm dia. 14 400mm dia. 15 450mm dia. 16 MS Dummy Flanges:-Manufacturing, Supplying & fixing of M.S. Dummy Flanges etc. of following sizes complete as required at site. 1200mm dia. & 25mm thickness. 17 350mm dia. & 16mm thickness. 18 400mm dia. & 25mm thickness. 19 C.I. Sluice Valves:-Providing & Fixing of following sizes Cast Iron Sluice gate Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 20 450 mm nominal dia. 21 C.I. Non Return Valves :-Providing & Fixing of following sizes Cast Iron Non Return Valve suitable for Pressure 1.0 PN complete in all respects as required at site. (Make: - Kirloskar/Kartar/Sant or as approved by Engineer-in-charge)350 mm nominal dia. 22 400 mm nominal dia. 23 Nut/Bolts/Washers:-Manufacturing & Supplying of Nuts,Bolts & Washers etc. of size 7/8 x 6 as required at site. 24 Rubber Gaskets:-Manufacturing, Supplying & Fixingof Rubber Gaskets of thickness 6mm or more for following sizes M.S. Pipelines Flanges as required at site.1200mm nominal dia. 25 350mm nominal dia. 26 400mm nominal dia. 27 450mm nominal dia. 28 Vaccum Pump:-Supplying, Installation, Testing and Commissioning of DV-50 Vaccum Pump sets having C.I. casing and C-40 shaft with 10 H.P. energy efficiency LV motor, 3 phase, 415volt 50hz, 1500RPM +/- 5%, TEFC induction motor mounted on suitable size M.S.base frame coupled on existing foundation withall accessories like ML 1.5 starter, anti vibration mounting pad, coupling, nut-bolts & packing etc. complete in all respect i/c providing, fitting & testing ofheavy class M.S. pipe of 50mm dia.of requiredlength with necessary Gate valve and mountings etc.for chargingof pump sets. ( Pump:- Kirloskar make or as approved by Engineer-in-charge) (Motor:- Kirloskar/Crompton /ABB or as approved by Engineer-in-charge) (Pipe make:- Jindal/ Surya/ Tata or as approved by Engineer-in-charge) 29 Supplying, installation, testing & commissioning of Energy efficient 630 KVA, 11/0.433 KV, 3 phase, 50Hz, Dyn11, outdoor ONAN type, copper wound Transformer with off load tap changing arrangement on HV side , Tapping range +5% to -10% in steps of 2.5%having Cable boxes on HV/LV side suitable for 3 x 240 Sq.mm. XLPE Cable of 11 KV grade with accessories, buckholz relay i/c first filling of filtered dehydrated oil and confirming to IS 335& Transformer losses as per IS 1180 level-2 & as per specification attached complete in all respects as required at site. • Max Continuous Rating = 630 KVA • Voltage Ratio = 11/0.433 KV• Tapping (Range/ Step) off Circuit Tap Changer = +5% to -10% in step of 2.5% off load • Insulation Class = A Class • Application of the Transformer = Distribution• Vector Group = Dyn 11• Temperature Rise at Rated Load over Ambient of 40°/50° C• Cooling = ONAN(Make:- Kirloskar/Schenider/ABB or as approved by Engineer-in-charge) 30 Supplying, Installation, Testing and Commissioning of Indoor Type Floor Mounted metal clad, 11KV VCB Panel with 1 No. VCB for ICOG System (Incoming-Outgoing System), Totally Enclosed. Horizontal drawout, Horizontal/Vertical Isolation type Breaker as per IS 13118 & as ammended upto date and additional specifications as mentioned below, manually charged and motorized /manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated Aluminium Bus Bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 3 x 95 sqmm XLPE 11 KV cable (cable entry frombottom/top/side) (MAKE:- Kirloskar/ L&T/ Crompton/Schenider)1. All CTs and PTs shall be cast resin type.2. 2. All PTs should be Fixed type.Detailed Specifications:-1 Nos. 800A TP Electrically drawout type Vacuum Circuit Breaker, 11KV, 20KA/3 seconds suitable for 630A TP, EDO, 18.4KA/1 second with following accessories:a)Spring Charge Motor, 240V A.C, Closing Coil 24V DC, Shunt Trip Coil 24V DC, Operation Counter with Mechanical ON/OFF Push Buttonb)Mechanical Indicator ON/OFF, Aux. Contacts 4NO + 4NC, Spring Charge/Discharge,Mechanical Spring Charging Device.c)Mechanical Emeregency Push Button2. 1 No. 11 KV / 110V PT class 0.5 accuracy and 100 VA burden with 1 No. voltmeter (0-15 kV), digital type, selector switch for voltmeter and protection fuses / MCB for HT metering up to 12 KV on incomer.3. 1 No. Microprocessor based numerical relay with O/L,E/F and S/C protection.4. 1 sets of 3 nos dual core dual ratio CTs 50/50/5/5A of 15 VA burden and accuracy class - 0.5 for metering and class 5P 10 for protection.5. Flush mounted Type High Speed Tripping Relay,6. Flush mounted Type DC Operated Auxiliary relay for Transformer Faults with Three Pair of Relay Element7. 1 Nos. Anti Pumping relay8. Annunciator Set 8 Window Type with Hooter for Fault Indication9. Supplying, Installation, Testing and Commissioning of Power pack with 220 volt AC input & 24 volt DC continuous output suitable for closing / tripping / indication of 1 No. HT Panel Boards with 2 Nos. 12 volts each maintenance free batteries of 100 AH each, charging unit, capacitor bank for emergency delivering for Trip system complete with suitable capacity of Ammeter & voltmeter i/c connections with 2.5 sqmm FRLS insulated copper conductor cable etc. as required. 31 Fabrication Supply Installation Testing and Commissioning of Main L.T Panel suitable for 415 Volt, 3 Phase 4 Wire System, 50Hz AC Supply. Panel Shall be fabricated out of 1.6MM thick CRCA Sheet for load bearing and non load bearing members, Gland Plate shall be fabricated out of 2MM thick CRCA Sheet. Panel shall be Powder coated with RAL 7032 Shade for Doors and Body and have suitable solid links for Incoming ond Outgoing of the ACB with Electrical Grade Aluminium of 1000 Ampere Capacity supported on DMC/SMC Bus Bar Supports. Earthing shall be done with 25 X 5MM G.I Strip running acroos the Panel Length. The Control Wiring for Metering and Display Instruments shall be done with PVC Insulated 1.1KV Grade multi stranded copper wire of 2.5 Sqmm. Proper Ventilation system for heat disipation shall be provided with Panel including ventialtion fan and louvers. The Panel Shall not be less than 1875 X 2000 X 750 m.m or Cm³(H,L&D) The Panel shall be fitted with the following switchgear & instruments as mentioned below:-Incoming:-a)1000A TP ACB, Manually Type with following protection features such as Overload and Shor Circuit protectionb)Digital Type Multifuntion Meter, bearing Cl 1 Accuracy without RS485 Portc)Phase Indication Lamps for R-Phase, Y-Phase and B-Phase, 240V A.Cd)ACB ON and OFF Indication Lampse)6A SP MCB, 10KA Breaking Capacity for Protection and Control Circuitf)1 Set of 1000/5 CT, CL-1.0, 15VA Burden Tape WoundOutgoing:-a)55KW Star Delta Starter with ML4 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosb)30KW Star Delta Starter with ML3 contractors and 200A TP MCCB 36KA Breaking Capacity with suitable Handle and Spreaders: 4 Nosc)400A TP MCCB, 36KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nosd)200A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.e)125A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 1 Nos.f) 100A TP MCCB, 25KA Breaking Capacity having Thermal Magnetic Release with O/L and S/C Protection : 4 Nos. 32 Supplying, installation, testing & commissioning of Cubical Type Phase sequence corrector suitable for 415 Volt, 3 Phase 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2mm thick CRCA sheet of size for frame work and covers, having Gland plate less than 3mm including cleaning and finishing complete with powder coating in approved shade, having links not less 600A capacity. the Bus Bar support (wherever required) with short curcuit withstand capacity of 31 MVA for 1 sec.Entire panel shall have a common Earth Bus of suitable size at the Rear with 2 Nos. Earth stud, solid connections from main Bus Bar to switch Gears with requires size of Aluminium Bus Bar (wherever required) and control wiring shall be done with 2.5 sq.mm PVC insulated copper conductor single core cables. Including providing and fixing the following switch Gear.A) Materiala) 580A Three Pole Power Contactors, AC3 Duty, Coil voltage 220 V A.C: 2 Nos. (Make:- ABB/L&T/C&S)b) LED type indication Lamps RYB (3 set) Aux. Supply: 220V A.Cc) Control Miniture Circuit Breaker (3 Nos.) SP, 10KA : 6Ad) Single Phase Digital Type Ampere Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 accuracy, CT-Input-5A, Aux. Volt-220V,ACe) Ampere Selector Switch (1No.) Rating : 6Af) Single Phase Digital Type Volt Metre, 3 Phase 4 wire system, Flush type 96 Sq.mm. (1 Nos.) Class-1 Accuracy, Range:- 0-500 V, Aux. Volt:220V, A.Cg) Voltage Selector Switch (1No.) Rating : 6Ah) Current transformer 600/5A, Single Ratio, Single Core, 1Ø (3 Nos.) , Tape wound, CL-1.0 & 15VAi) LED type Indication LampsON/OFF (2 set) Aux. Supply: 220V A.Cj) Auto/ Manual selector switch (2 Nos.), Rating : 6Ak) Phase Sequence correction relay (1 Nos.) Aux Volt :220V, A.Cl) Audio Indication for Phase sequence Reversal(1 Nos.) Hooter : 220V A.C.m) On Delay Timer (1 Nos.) Aux Volt :220V, A.C 33 SITC of 200KVAR APFC Panel made out of 1.6mm Thick CRCA Sheet duly powder coated complete with suitable size of Al. Bus Bars & internal wiring with suitable size of Copper wire including Providing and Fixing following Switchgear and Metering instruments complete as required. Panel size shall not be less than 1575m.m or Cm³*1900*350.. the Capacitors Shall be Divided as per the mentioned Pattern for 200KVAR SystemA) MaterialMain Incomer:-a) 400A TP MCCB, Thermal based Release with O/L & S/C Protection: 1 Nos.b) Rotary Operating Mechanism: 1 Nos.c) Phase Spreaders: 1 Setd) 12 Stage APFC Relay, Microprocessor Based, with Different Display Parameters.e) Phase Indication Lamps, 220V-240V AC : 3 Nos.2) Outgoing:-a) 63A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 6 Nosb) 40A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.c) 25A TP MCCB, Thermal Magnetic Release with O/L & S/C Protection, with ROH and Spreaders: 2 Nos.3) 200 KVAR Capacitor, MPP and Cylindrical Type:-a) 25KVAR Capacitor Bank: 6 Nos.b) 15KVAR Capacitor Bank: 2 Nos.c) 10KVAR Capacitor Bank: 2 Nos.4) Capacitor Duty Contactors of Various Ratings for Capacitor Switching:-a) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 25 or Equivalent : 6 Nosb) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 15 or Equivalent : 2 Nosc) Capacitor Duty Contactors for 25KVAR Cap. Bank , MOC 10 or Equivalent : 2 Nosd) Side Mounting Block : 10 Nose) Push Button with Element Set for Manual Start & Stop of Capacitor Bank : 10 Setsf) Indication Lights for Capacitor ON Indication : 20 Nos.g) 4 Ventilation Fans with Louvers for Cross Air Ventilation : 1 Nosh) Auto/Manual Selector Switch for Auto/Manual mode of Operation : 1 Nos. 34 Copper Conductor LT Cables:-Supplying, Laying and fixing of following sizes P.V.C. insulated and P.V.C. sheathed/ XLPE CopperConductorarmoured Cable of 1.1 KV grade as per IS:1554 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)4C x 10 sqmm. 35 4C x 120 sqmm 36 4C x 150 sqmm 37 Aluminium Conductor LT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 1.1 KV grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. (Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge)3.5C x 300 sqmm 38 3.5C x 150 sqmm 39 Aluminium Conductor HT Cables:-Supplying, Laying and fixing of following size P.V.C. insulated and P.V.C. sheathed/ XLPE AluminiumConductorarmoured Cable of 11 KV(E) grade as per IS:7098 or amendment up-to-date on surface including connection making, taping etc. complete as required. 3.5C x 300 sqmm(Make:- National/Grandlay/ Glouster/ Poly-Cab/ Havells/ Phinolex or as approved by the Engineer-in-charge) 40 Supply and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 16 sq. mm 41 4 x 35 sq. mm 42 4 x 10 sq. mm 43 Supply and making outdoor end jointing with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 11 KV grade as required.3C x 300 sq. mm 44 Supplying & fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth busbar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 6 way, Double door 45 8way, Double door 46 Supplying and fixing metal box of 100mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 47 Supplying, installation, testing & commissioning of energy efficient LED Flood light luminaries of system wattage 72 watt complete with mounting brackets & accessories i/c connections complete as required.(Make:- Bajaj/Philips/Crompton/Halonix) 48 Supplying and fixing followingpiano type switch/socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch 49 15/16 amp switch 50 3 pin 5/6 amp socket outlet 51 6 pin15/16 amp socket outlet 52 Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc. as required. 53 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, , miniature circuit breaker suitable for inductive load of folloeing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole 54 Single pole and neutral 55 Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVS insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular plate, sitable GI Box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C) 56 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2x2.5 sq.m + 1x2.5 sq.m earth wire 57 2 x 4 sq. mm +1 x 4 sq.mmearth wire 58 Supplying, installation, testing and commissioning ofHeavyduty following sizes exhaust fan 900 RPM totally enclosed heavy duty motor with die castaluminium rotor suitable for operation on 240 volts 50 Hz AC single phase Supply including installation of exhaust fan in the existing opening, making good the damages as required. .(Bajaj, Usha, Khaitan, Havells, Orient ) or as approved by Engineer-in-charge.450 mm Sweep 59 Supplying, installation, testing and commissioning of 1200 mm sweep AC electric ceiling fan capacitortype with double ball bearing complete with down rod, canopies, shackles, blades but without regulator suitable for operation on 230/240 volts, 50 Hz single phase AC supply including wiring the down rod of standard lenth up to 1 mtr with 2x1.5 sq. mm PVC insulated copper conductor with fan sheet etc. as required.(Make:- Bajaj/ Usha/ Khaitan/ Havells/ orientor as approved by Engineer-in-charge) 60 Supplying, installation, testing & commissioning of prewired Indoor decorative 18/20 watt LEDbatten extruded aluminum housing& opal diffuser. IP20 complete with all accessories including connection making etc. as required. (Make:- Bajaj/ Halonix/ Havell’s/ Crompton/ Phillipsor as approved by Engineer-in-charge) 61 Supplying and fixing of following size P.V.C. insulated sheathed /XLPE Aluminum conductor cable of 1.1 KV Grade armoured as per IS:7098 on surface as required. (National,Grandlay, Glouster, Poly-Cab, Phinolex or as approved by Engineer-in-charge). 2 x 10 sq.mm 62 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. 63 Providing and fixing 25 x 5 mm G.I.strip on surface or in recess including connection etc. as required. 64 Providing and laying 6 SWG G.I wire on surface or in recess for loop earthing along with existing surface/recessed/conduit/submain wiring/cable etc. as required. 65 Supplying, Installation, Testing and commissioning of 7.5 Tonne capacity Single Girder E.O.T. Crane comprising of Main Girder, End carriages -02 nos with long travel motors – 02 Nos, 01 Nos 5 Tonne capacity Wire Rope Electric Hoist, pendant controlled along with brakes, limit switches and electric panel. All motors i.e. Hoisting/ Lowering, cross travel and long travel shall be compatible with VVVF drive and the speeds can be adjusted from zero to maximum speed. The complete system includes erection of columns, LT Girders, LT rail/ Sq Bar, 01 no DSL system (Shrouded type)(MAKE: - GLOBE/ WH BRADY/ GARLIC) 66 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 150 Watt LED street lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge) 67 Supplying, Installation, Testing and commissioning ofNew Generation Energy Saving & Environment friendly long versatile pressure die cast aluminium IP 66 roadway luminaire with high power 100 Watt LED Flood lights complete with all accessories etc. as required.(Make:- Phillips/Bajaj/Crompton/Halonix/ Havells or as approved by Engineer-in-charge). 68 Fabrication & installation of S.S. Bar Screen/ Jaal inside Suction side of Pump Sump in slightly inclined position of required height with M.S. Platform etc. for ease of removal of foreign materials, hyacinth, jute, bags etc. from the suction side completed etc. as required at site.Construction, maintenance and subsequent removal of earthen bundies including cost of excavation earth filling of E.C. bags with earth, stitching and placing in position for care and diversion of all kinds of water entering or flowing in the drain and pumping out surface as well as under groung seepage water to keep the construction area completely dry for execution of entire work including its execution of work in or under water and or liquid mud wherever required with round the clock watch & ward/maintenance of earthen bundies to keep the working area/site dry complete as per specification & direction of Engineer-in-charge. 69 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500 D or more. 70 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. 71 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cementconcrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverableseparately). All works upto plinth level. 72 Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 73 Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as Nuts, Bolts,fasteners etc.).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
10.
Educational and Research Institute #10524394 Price Bid
Supply And Installation Of Equipments , Tools , Instruments , Machineries Etc For Itahar Govt Polytechnic-2 Digital Logic Trainer Board ( In Build Bread Boards Provision ) 3 Ic 4 7 Segment Led Display 5 Resistance 6 Led 7 Jumper Wire 8 Jumper Wire Cutter 9 Twizzer 10 Magnifying Glass 11 Function Generator 12 Diode Trainer Kit 13 Transistor Trainer Kit 14 Operational Amplifier Trainer Kit 15 Electronic Trainer Board ( In Build Bread Boards Provision ) 16 555 Timer In Astable, Monostable Operation 17 Discrete Components Resister 18 Digital Multimeter 19 Discrete Components Capacitors 20 Dual Channel Cro 30Mhz 21 8086 Trainer Kit 22 8086 Simulation Software 23 Unmanaged Switch 24 Hub 25 Cat 5E / 6 Cable 26 Rj 45 Connectors 27 Rj 45 Crimping Tools 28 Network Lan Cable Tester ( Rj 45 ) 29 Access Point ( Wifi Router / Wireless Router ) 30 Software 31 Software 32 Software 33 Software 34 Software 35 Software 36 Software 37 Software 38 Software 39 Software 40 Software 41 Software 42 Software 43 Software 44 Software 45 Software 46 50 Mhz Dual Channel Cro. 47 Function Generator 48 Digital Multimeter 49 50 Mhz Dual Trace Cro 50 Variable Dc Power Supply 51 Diode Trainer Kit 52 To Study The Rectifier With And Without Capacitor Filter For : — N ( A ) Half-Wave Rectifier, N ( B ) Full-Wave Rectifier, N ( C ) Bridge Rectifier N N 53 To Study The Output Waveform Of Push-Pull Amplifier For Class-A, Class-B & Class-Ab Operations 54 To Study The Fet Characteristics Trainer 55 To Determine Frequency Response Characteristics Of Rc Coupled Amplifier Circuit And Calculation Of Nbandwidth, Midband Gain, Input Impedance And Output Impedance For : N ( A ) Single-Stage Amplifier N ( B ) Double-Stage Amplifier N 56 Fet Characteristic Trainer Kit 57 Mosfet Characteristics Trainer Kit 58 Shunt And Series Regulator Trainer Kit For Following Plots: Line Regulation And Load Regulation 59 To Study The V-I Characteristics Of Ujt Trainer Kit. 60 To Study The Input And Output Characteristics And To Find The H-Parameters Of A Bjt For : — N ( A ) C-E Configuration, N ( B ) C-C Configuration, N ( C ) C-B Configuration N 61 Feedback Amplifier Trainer 62 Tuned Amplifier Trainer 63 Oscillator Trainer Kit 64 To Determine The Following Characteristics Of Op-Amp: —A ) Input Offset Voltage, B ) Slew Rate, C ) Non-Inverting Gain, D ) Inverting Gain E ) Adder, F ) Subtractor, G ) Differentiator, H ) Integrator And I ) Voltage Follower 65 To Study The Waveform Of Ujt As Relaxation Oscillator. 66 To Study The Characteristics Of Ic555 Timer Connected As:A ) Astable Multivibrator, B ) Monostable Multivibrator. 67 Multi O / P Programmable Linear Dc Power Supply 68 Digital Trainer Kit ( Experiment 1. -To Verify The Truth Table Of Not, Or, And, Nand, Nor, Xor, X-Nor With Ttl Logic Gates And Cmos Logic Gates. Experiment 2.- To Realize Different Boolean Expressions With Logic Gates. Experiment 3.-To Realize Half-Adder, Full-Adder, Subtractor, Parallel And Serial Full-Adder. Experiment 4-To Design 1’S Complement, 2’S Complement And 9’S Complement Adder-Subtractor. ) 69 Complete Setup To Design / Construct Programmable Up / Down Counter. 70 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer. 71 Complete Setup To Design Controlled Shift Register And Study Their Function. 72 Complete Setup To Design / Construct Parity Generator, Checker And Comparator 73 Complete Trainer Kit Of A To D Converters 74 Complete Setup To Design / Construct Binary Synchronous And Asynchronous Counter 75 D / A Converter Trainer 76 Digital I.C Tester 77 A / D & D / A Converter Trainer 78 To Verify The Mesh Analysis And Node Analysis Using Independent And Controlled Source 79 To Verify Thevenin’S And Norton’S Theorems 80 To Verify Maximum Power Transfer Theorem 81 To Verify Superposition Theorem 82 To Study The Series And Parallel Resonant Circuit 83 To Measure The Characteristic Impedance Of Symmetrical T And Ii Networks 84 To Test And To Measure The Cut –Off Frequencies Of The Following: — ( A ) Constant K-Type Low Pass Filter; ( B ) Constant K-Type High Pass Filter 85 To Test T And Pi Attenuator 86 To Study Standing Wave Pattern For A Transmission Line Of Finite Length With: ( A ) Open Termination, ( B ) Shorted Termination And Matched Termination. 2.To Measure The Attenuation Constant And Phase Shift Constant For Matched Termination 87 To Study The Given Rc Integrator And Differentiator At Different Time Constant 88 Study The Construction Features Of Dc Machine 89 To Control The Speed Of D.C. Shunt Motor Above Normal Speed & Draw The Speed Characteristics 90 To Control The Speed Of D.C. Shunt Motor Below Normal Speed & Draw The Speed Characteristics 91 To Determine Equivalent Circuit Parameters Of Single-Phase Transformer By Performing ( I ) O.C. Test ( Ii ) S.C. Test. 92 Study Of Three Point And Four Point Starter 93 Computer Programming Language Laboratory 94 8085 Microprocessor Traineer Kit 95 Microprocessor 8086 Trainer Kit 96 To Study The Amplitude Modulation And Demodulation Ttrainer Kit 97 Am / Fm Radio Receiver Kit 98 Analog Signal Sampling & Reconstruction Trainer Kit 99 Pulse Code Modulation And Demodulation System Trainer 100 Frequency Modulation And Demodulation Kit 101 Delta / Sigma Delta And Adaptive Delta Modulation Demodulation Kit 102 Dpcm & Adpcm Modulation / Demodulation Kit 103 Epbax Trainer Kit 104 Black & White Tv Trainer Kit With Provision Of Fault Finding 105 Dth Tv And Set Top Box Trainer Kit 106 Colour Tv Trainer With Provision Of Fault Finding 107 Tdm Pulse Code Modulation 108 Tdm Pulse Code Demodulation Trainer Kit 109 To Study The V-I Characteristic Of Gunn Diode. 110 Fdm Transmitter / Receiver Kit 111 Digital Storage Oscilloscope 112 Spectrum Analyzer 113 Antenna Trainer 86 - 860 Mhz 114 Microwave Test Bench ( Klystron Based ) 115 Ask / Psk / Fsk Modulation And Demodulation Kit 116 Microwave Test Bench ( Gunn Based ) 117 Antenna Trainer 86 - 860 Mhz ( With Pc Interfacing And Automatic Turntable And Necessary Plotting Software ) 118 Antenna Trainer 86 - 860 Mhz ( Manual Antenna Rotation Set Up ) 119 1 Ghz Spectrum Analyser 120 Antenna Trainer Kit 121 Microwave Power Meter 122 Trainer Kit To Study Reverse Recovery Characteristics Of Power Diodes 123 Power Transistor Drive Ckt Study Kit 124 To Study Drive Circuit Of Scr 125 To Study A Single Phase Rectifier—Output Waveform With Phase Control Circuit 126 To Plot V / I Characteristics Of Triac 127 To Study A Polyphase Rectifier 128 To Study Smps With Pwm Regulator Chip 129 To Plot V / I Characteristics Of Diac 130 To Study A Phase Control Ac Regulator 131 Servo Regulator Stabilizer Study Kit 132 To Study A Jones Chopper 133 To Study Speed Control Of Induction Motor By Voltage And Frequency Variation 134 To Study The Speed Control Of Dc Motor By: ( A ) Varying Field Current Keeping Armature Voltage Constant; And, N ( B ) Varying Armature Voltage Keeping Field Current Constant N 135 Power Electronics Devices Trainer Kit 136 Stepper Motor Study Set 137 Single Phase Bridge Inverter 138 Plc Trainer ( Experiment 1-Use Of Simulation Package For Different Function Of Plc. Experiment 2- Verify Function Of Logic Gates By Using Plc. Experiment 3- Write And Verify Ladder Program For Motor On-Off Control With Two Push Button ) 139 1 Kva Online Ups Trainer Kit 140 Stepper Motor Kit 141 2Mhz Function Generator 142 Power Electronics Development Trainer 143 1. To Study The Operation And To Use: ( A ) Multimeter, And, ( B ) Oscilloscope 2. To Study The Operation And To Use: N ( A ) Af Signal Generator; And, ( B ) Rf Signal Generator N3. To Study The Operation And To Use Frequency Counter N4. To Study The Operation And To Use Frequency Generator N 144 Digital Lcr Meter 145 Distortion Factor Meter 146 To Measure L & Q By Maxwell Method 147 To Measure The Unknown Capacitance By Schering Bridge 148 To Measure The Distortion In A Given Waveform 149 To Construct And Test A Q-Meter 150 To Study The Spectrum Analyzer 151 To Measure The Unknown Frequency By Wein Bridge 152 Microcontroller Trainer Kit 1.Write A Simple Assembly Programs For Na. Addition B. Subtraction B. Multiplication D. Division N2. Write A Programs For ( Any Two Of The Following ) Ni. 4 X 4 Matrix Keypad Interface Nii. Character Based Lcd Interface Niii. Analog To Digital Conversion ( On Chip Adc ) Niv. Serial Eeprom Nv. Seven Segment Led Display Interface Nvi. Interfacing With Temperature Sensor Nvii. Stepper Motor Interface N 153 Microcontroller Simulation Software 154 To Study The Function Of Fibre Optic Analog Link.To Study The Frequency Response Of Optical Receiver At Various Load Conditions. N3. To Study The Losses In Optical Fibre:— N ( A ) Propagation Loss, ( B ) Bending Loss. N4. To Study The Numerical Aperture Of Optical Fibre N 155 To Be Familiar With The Following Network Components 156 To Be Familiar With Mobile Telephone 157 To Be Familiar With Cordless Telephone 158 To Be Familiar With Fax 159 Network Components 160 24 Port Managed Switch 161 24 Port Unmanaged Switch 162 8 Port Hub 163 Access Points 164 Network Passive Component For Networking 165 Lan Trainer 166 Pc Based Optical Fiber Lan Trainer Package 167 Installation & Commissioning Of Network 168 To Measure Displacement With Lvdt 169 To Measure Temperature With Thermocouple 170 To Measure Temperature With Thermistor 171 To Measure Pressure With Strain Gauge 172 To Plot The Characteristics Of Rtd ( Pt-100 ) 173 Temperature Controller With On-Off Controller, Temperature Controller With Pi Controller, Temperature Controller With Pid Controller 174 Oscilloscope 175 Function Generator 176 Experimentation With Transistor Characteristics 177 Common Emitter Amplifier 178 Ujt Characteristics 179 Trainer Kit For Fet Characteristics 180 Trainer Kit For P-N Junction Diode & Zener Diode Characteristics 181 Trainer Kit For Superposition, Thevenins Theorem, Nortons & Max Power Transfer 182 Series Parallel Resonance Of R-L-C Ckt 183 Motor Winding Trainer 184 Automatic Coil Winding Machine 185 Three Point & 4 Point Starter 186 Digital Earth Resistance Tester 187 Digital Multimeter 188 Low Power Factor Analog Watt Meter 189 Power Factor Meter ( Single Phase ) 190 Power Factor Meter ( 3-Phase ) 191 Clamp On Ammeter 192 Calibration Of 3 Phase Energy Meter 193 Kelvin Double Bridge 194 Maxwells Bridge 195 Schearing Bridge 196 Single Phase & 3- Phase Digital Energy Meter With Single Phase & 3 Phase Resistive Load 197 3-Phase With Neutral Resistive Load Box 198 Clip On Type Ammeter 199 Heat Run Test Of A Single Phase Transformer 200 Heat Run Test Of A Single Phase Transformer 201 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test 202 3 Phase Transformer For Different Connections 203 D, C. Shunt Generator For Open Circuit Test 204 Load Test Of Dc Series Motor 205 Swinburns Test Of Dc Motor 206 Dc Shunt Motor For Speed Control & Load Test 207 D.C. Compound Motor ( Open Type ) 208 Variable Resistor Wire-Wound Type, Tubular 209 D.C. Power Supply, -I / P-440V, 3 Phase. O / P-220V, 50A 210 3-Phase Autotransformer Starter 211 Different Starters For Induction Motor 212 3 Phase Synchronous Motor With Starter 213 Starting & Reversing Of Single Phase Induction Motor 214 Induction Motor To Measure Slip By Stroboscopic Method 215 Slip Ring Induction Motor For T-S Curve 216 3 Phase Induction Motor ( Semi Open Type ) 217 Multipole Squirrel Cage Induction Motor 218 No-Load Test, Blocked Rotor Test & Load Test Of Induction Motor 219 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method 220 Determination Of Parameter & Regulation Of A Three Phase Alternator 221 Tachometer 222 D.C. Servometer Speed Control - Trainer Kit 223 L.V.D.T. To Measure Non Electrical Quantity 224 Proportional, Differential & Integral Controller 225 Strain Gauge & Measurement Of Strain 226 Study Of Proximity Switch 227 Study Kit Of Thermocouple And Temperature Measurement By Thermocouple 228 Demo Board For Different Insulator 229 Dielectric Strength Test Set For Transformer Oil 230 Digital Insulation Tester 231 Digital To Analogue Converter With Power Supply 232 Complete Setup To Design / Construct Binary Synchronous And Asynchronous Counter 233 Complete Setup To Design / Construct Parity Generator, Checker And Comparator 234 Complete Setup To Design / Construct Programmable Up / Down Counter 235 Complete Setup To Design Controlled Shift Register And Study Their Function 236 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer 237 Complete Trainer Kit Of Ad Converters 238 Digital Trainer Kit 239 Master Slave J-K Flip-Flop Using Nand Gates With Power Supply 240 Study Of Universal Logic Gates & Napplications With Power Supply N 241 Experimentation With Fet Amplifier 242 Trainer Kit For Colpitt Oscillator 243 Trainer Kit For Wien Bridge Oscillator 244 Trainer Kit For Potentiometer Characteristics 245 D.C. Series Motor Speed Control Trainer ( Scr Driver ) Kit 246 Trainer Kit For Astable, Monostable & Bistable Multivibrator Using Ic-555 247 Trainer Kit For Scr Characteristics 248 Trainer Kit Of Dc Chopper Using Scr 249 Trainer Kit To Study Single Phase Full Bridge Full Controlled Converter ( Rectifier & Inverter ) Using Scr 250 Trainer Kit To Study Integrator & Differentiator Using Opamp-741 251 Trainer Kit To Study On The Applications Of Op-Amp 252 Speed Control Of Induction Motor 1Ph By Using Scr 253 Online Ups Demonstration Kit 254 D.C Network Analyzer 255 Thermal Over Current Relay 256 C.T. & P.T. Testing Trainer Kit 257 Current Differential Relay , Idmt Type 3 Phase Transformer With Fault Creation Arrangement 258 Induction Type E / F Relay 259 M.C.B. Demo Board 260 Transformer Differential Relay 261 To Test Directional Over Current Relay ( Docr ) By Relay Testing Kit 262 3-Phase Alternator Protection Simulator 263 8085 Microprocessor Trainer Kit 264 8085 Microprocessor Based Controller For The Operation Of A Stepper Motor With A Fixed No.Of Steps And To Determine The Angular Displacement Per Step By Measuring The Total Angular Rotation 265 Control Of Dc Motor At Different Speed And To Note Speed Vs Load Characteristics At Open Loop Conditions By 8085 Microprocessor Based Controller 266 Set Up For Checking Of The Phase Sequence Of Three Phase Supply System Using Three Zero Crossing Detectors Controlled By 8085 Microprocessor 267 Set Up For Measurement Of Ac Voltage, Current, Frequency And Phase Angle Difference Using Suitable Pt, Ct, Zcd, Adc, Etc Based On 8085 Microprocessor 268 Set Up For Over Voltage / Under Voltage Or Over Current / Under Current Relay Ckt Using Suitable Hardware Ckt Controlled By 8085 Microprocessor 269 8051 Microcontroller Trainer Kit Nmicroprocessor And Microcontroller N 270 Halogen Lamp 271 Cfl Lamp 272 Trainer For Sodium Vapour Lamp, Mercury Vapour Lamp 273 Lux- Meter 274 Lead Acid Battery With Charger 275 Protable Grinding Machine 276 Electric Power Drill 277 3-Phase Contactor Unit 278 Solder & De-Solder Including Soldering Iron Flux ( Kit ) 279 Dc Power Supply 280 Analog Dc Voltmeter 281 Analog Ac Voltmeter 282 Analog Ac Ammeter 283 Analog Dc Ammeter 284 Analog Wattmeter
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 15
West Bengal View Result →
11.
Power #10279329 Price Bid
Annual Rate Contract Of Transformer Repairing Material For The Financial Year 2023-24 , Supply Of Dpc Aluminum Winding Wire ( Round ) In Sizes 12, 13, 14, 16, 18, Swg . ( Conforming To Is:6162 ( Part-Ist 1971 ) With Latest Revision. Aluminum Conductor Made From Ec Grade Aluminum Rods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160, Covered With Dpc Of Electric Grade Kraft Paper Conforming To Is:9335 ) Isi Mark / Bis Certified , ( Exchange Rate ) Dpc Aluminum Winding Wire ( Round ) In Sizes12, 13, 14, 16, 18 Swg Swg In Lieu Of 1Kg Old Salvaged Coil ( Conforming To Is:6162 ( Part-I 1971 ) With Latest Revision. Aluminum Conductor Made From Ec Grade Aluminum Rods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160, Covered With Dpc Of Electric Grade Kraft Paper Conforming To Is:9335 ) Isi Mark / Bis Certified , Aluminum Strip Of Sizes For Lv Winding Of Dist. Transformers 25Kva To 1 Mva ( Conforming Tois:6160-1971& Is:6162 ( Part-Ii ) 1971With Latest Revision. Aluminum Conductor Made From Ec Grade Aluminum Rods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160, Covered With Dpc Of Electric Grade Kraft Paper Conforming To Is:9335 ) Isi Mark / Bis Certified , Super Enameledaluminum Winding Wire ( Round ) In Sizes 13, 16, 18, 21 Swg ( Conforming To Is:13730-17 / 13778-1993 With Latest Revision. Aluminum Conductor Made From Ec Grade Aluminum Rods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160 ) Isi Mark / Bis Certified , ( Exchange Rate ) Super Enameledaluminum Winding Wire ( Round ) In Sizes 13, 16, 18, 21 Swg In Lieu Of 1Kg Old Salvaged Coil ( Conforming To Is:13730-17 / 13778-1993With Latest Revision. Aluminum Conductor Made From Ec Grade Aluminum Rods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160 ) Isi Mark / Bis Certified , Dpc Copperwinding Wire ( Round ) In Sizes 13, 11, 12, 14, Swg . ( Conforming To Is:6160-1971With Latest Revision.Copperconductor Made From Ec Grade Copperrods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160, Covered With Dpc Of Electric Grade Kraft Paper Conforming To Is:9335 ) Emco Or Equivalent Make , ( Exchange Rate ) Dpccopperwinding Wire ( Round ) In Sizes 13, 11, 16, 14, 18, Swg Swg. ( Conforming To Is:6160-1971With Latest Revision.Copperconductor Made From Ec Grade Aluminum Rods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160, Covered With Dpc Of Electric Grade Kraft Paper Conforming To Is:9335 ) Emco Or Equivalent Makein Lieu Of 1Kg Old Salvaged Coil Isi Mark / Bis Certified , Super Enamledcopperwinding Wire ( Round ) In Sizes 13, 11, 12, 14, Swg . ( Conforming To Is:13730-17 / 13778-1993 With Latest Revision.Copperconductor Made From Ec Grade Copperrods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160 , ( Exchange Rate ) Super Enamaledcopperwinding Wire ( Round ) In Sizes 13, 11, 16, 14, 18, Swg Swg. ( Conforming To Is:13730-17 / 13778-1993 With Latest Revision.Copperconductor Made From Ec Grade Aluminum Rods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160, In Lieu Of 1Kg Old Salvaged Coil Isi Mark / Bis Certified , Lt Copperstrip Of Sizes For Lv Winding Of Dist. Transformers 250 Kva To 1 Mva ( Conforming Tois:6160-1971& Is:6162 ( Part-Ii ) 1971With Latest Revision.Copper Conductor Made From Ec Grade Copperrods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160, Covered With Dpc Of Electric Grade Kraft Paper Conforming To Is:9335 ) Isi Mark / Bis Certified , Exchange Rate Copperstrip Of Sizes For Lv Winding Of Dist. Transformers 250 Kva To 1 Mva ( Conforming Tois:6160-1971& Is:6162 ( Part-Ii ) 1971With Latest Revision. Copperconductor Made From Ec Grade Copperrods Of 99.6% Purity Conforming To Is:5484-1978 With High Conductivity, Hot Rolled And Annealed As Per Is:6160, Covered With Dpc Of Electric Grade Kraft Paper Conforming To Is:9335 ) , Lv Brass Bush Rods 12 Mmx180mm ( Conforming To Is:3347 / 1967. Made Up Of Free Machining Brass Rod. Complete With Neoprene Seal Rings, Locking Nuts &Other Accessories As Per Sample. Working Voltage 1.1Kv, Current Ratingup To 250 Amp ) , Lv Brass Bush Rods 19 Mm X 250 Mm ( Conforming Tois:3347 / 1967. Made Up Of Free Machining Brass Rod. Complete With Neoprene Seal Rings, Locking Nuts &Other Accessories As Per Sample. Working Voltage 1.1Kv, Current Ratingup To 400 Amp ) , Lv Brass Bush Rods 25 Mmx270 Mm ( Conforming Tois:3347 / 1967. Made Up Of Free Machining Brass Rod. Complete With Neoprene Seal Rings, Locking Nuts &Other Accessories As Per Sample. Working Voltage 1.1Kv, Current Ratingup To 400 Amp ) Isi Mark / Bis Certified , Lv Brass Bush Rods 32 Mm X 280 Mm ( Conforming Tois:3347 / 1967. Made Up Of Free Machining Brass Rod. Complete With Neoprene Seal Rings, Locking Nuts &Other Accessories As Per Sample. Working Voltage 1.1Kv, Current Ratingup To 630 Amp And Above ) Isi Mark / Bis Certified , Lv Brass Bush Rods 38Mm X 320 Mm ( Conforming Tois:3347 / 1967. Made Up Of Free Machining Brass Rod. Complete With Neoprene Seal Rings, Locking Nuts &Other Accessories As Per Sample. Working Voltage 1.1Kv, Current Ratingup To 800 Amp And Above ) Isi Mark / Bis Certified , Hv Brass Bush Rods 12 Mm ( Conforming Tois:3347 / 1967. Made Up Of Free Machining Brass Rod. Complete With Neoprene Seal Ring’S, Locking Nuts & Other Accessories As Per Sample. Working Voltage 12Kv, Current Ratingup To 250 Amp ) Isi Mark / Bis Certified , Press Card Board 3X4soft Calendared-Solid 1Mm / 2Mm / 3Mm ( As Per Sample ) ( Type C Conforming To Is:1576 ) Isi Mark / Bis Certified , Press Card Board Pre-Compressed Solid 1Mm / 2Mmtype B 3.1 Of Iec 641-3-23Mm ( As Per Sample ) Isi Mark / Bis Certified , Insulatingttransparent Gum ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Glass Sleeves 2 Mm , 1 Mt Long ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Glass Wool Sleeves 3 Mm, 1 Mt Long ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Glass Wool Sleeves 4 Mm, 1 Mt Long ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Glass Wool Sleeves 6 Mm, 1 Mt Long ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Glass Wool Sleeves 12 Mm, 1 Mt Long ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Glass Wool Sleeves 16 Mm, 1 Mt Long ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Aluminumbrazing Rod ( Std. Length ) ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Copper Brazing Rod ( Std. Length ) ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Pvc Sheets 1Mmthick ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Pvc Sheets7mmthick ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Empire Tape / Electrical Tape ( Vinyl& Varnished Cambric ) 20-40 Mm 20 Mts Rollthickness 4 / 5 / 7 / 10 Mils , Standard Make Conforming To Relevant Is With Latest Revision Isi Mark / Bis Certified , Electrical Grade Kraftpaper, 1 / 2 / 3 / 4 / 4 / 5Mil ( Conforming To Is:9335 Type 1.2-2M Of Iec 554-3-1 ) Isi Mark / Bis Certified , Lathoride Paper 10 / 15 / 20 Mil ( Standard Make Conforming To Relevant Is: With Latest Revision ) Isi Mark / Bis Certified , Hv Bushing ( Conforming To Is:3347 ( Part Iii / Sec 1 ) &Is-2099. Transformer Rating 25-1000Kva, Visible Discharge Voltage 9Kv, Working Voltage Up To 12 Kv, Impulse Withstand Voltage 95Kvp, P.F Withstand Voltage 40Kv ) ( Hv Bush ) Isi Mark / Bis Certified , Lv Bushes With Cupsfor 25Kva ( Conforming To Is:3347 ( Part Iii / Sec 1 ) &Is-2099&Is 7421-1974Transformer Rating Up To 25Kva, Working Voltage 1.1 Kv, Current Rating 100 Amp, P.F With Stand Voltage 12Kv ( As Per Sample ) Isi Mark / Bis Certified , Lv Bushes With Cupsfor 63Kva ( Conforming To Is:3347 ( Part Iii / Sec 1 ) &Is-2099&Is 7421-1974Transformer Rating Up To 63Kva, Working Voltage 1.1 Kv, Current Rating 100Amp, P.F With Stand Voltage 12Kv ( As Per Sample ) Isi Mark / Bis Certified , Lv Bushes With Cupsfor 100Kva ( Lv Bushes With Cupsfor 100Kva ( Conforming To Is:3347 ( Part Iii / Sec 1 ) &Is-2099&Is 7421-1974Transformer Rating Up To 100 Kva, Working Voltage 1.1 Kv, Current Rating 133 Amp, P.F With Stand Voltage 12Kv ( As Per Sample ) Isi Mark / Bis Certified , Lv Bushes With Cupsfor 250Kva ( Conforming To Is:3347 ( Part Iii / Sec 1 ) &Is-2099&Is 7421-1974Transformer Rating Up To 100 Kva, Working Voltage 1.1 Kv, Current Rating 400 Amp, P.F With Stand Voltage 12Kv ( As Per Sample ) Isi Mark / Bis Certified , Lv Bushes With Cupsfor 400Kva ( Conforming To Is:3347 ( Part Iii / Sec 1 ) &Is-2099&Is 7421-1974Transformer Rating Up To 100 Kva, Working Voltage 1.1 Kv, Current Rating 600 Amp, P.F With Stand Voltage 12Kv ( As Per Sample ) Isi Mark / Bis Certified , Lv Bushes With Cups For 630Kva ( Conforming To Is:3347 ( Part Iii / Sec 1 ) &Is-2099&Is 7421-1974Transformer Rating Up To 100 Kva, Working Voltage 1.1 Kv, Current Rating 1500 Amp, P.F With Stand Voltage 12Kv ( As Per Sample ) Isi Mark / Bis Certified , Lv Bushes With Cups For 1000Kva ( Conforming To Is:3347 ( Part Iii / Sec 1 ) &Is-2099&Is 7421-1974Transformer Rating Up To 100 Kva, Working Voltage 1.1 Kv, Current Rating 2000 Amp, P.F With Stand Voltage 12Kv ( As Per Sample ) Isi Mark / Bis Certified , Cotton Tape 1” ( Size ) ( Conforming To Is 1923 ) 35 Mtsisi Mark / Bis Certified , Nawar Tape 1.25” / Of Sizes ( Conforming To Is 1923 ) 50 Mtsisi Mark / Bis Certified , Rubberized Cork Sheet ( Oil Resistant ) 4Mm Thick2ft X 3Ft ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) Isi Mark / Bis Certified , Rubberized Cork Sheet ( Oil Resistant ) 3.Mm Thick 2Ft X 3Ft ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) Isi Mark / Bis Certified , Rubberized Cork Sheet ( Oil Resistant ) 3. 5 Mm Thick 2Ft X 3Ft ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) Isi Mark / Bis Certified , Rubberized Cork Sheet ( Oil Resistant ) 5 Mm Thick 2Ft X 3Ft ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) Isi Mark / Bis Certified , Bakelite / Fibertubes8 Mm Dia ( 1 Mt Long ) ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Bakelite / Fibertubes10 Mm Dia ( 1 Mt Long ) ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Bakelite / Fibertubes12mm Dia ( 1 Mt Long ) ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Bakelite / Fibertubes14mm Dia ( 1 Mt Long ) ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Bakelite / Fibertubes16 Mm Dia ( 1 Mt Long ) ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Hv Bush Clamps ( Ms ) ( Standard Make Conforming To Relevant Is With Latest Revision ) With Holder Including Nuts And Bolts With Washers Isi Mark / Bis Certified , Al. Clamping Member ( Shoes ) For Hv Bushing ( Standard Make Conforming To Relevant Is With Latest Revision ) Isi Mark / Bis Certified , Galvanizedfull Thread Nuts & Bolts With Washersof Sorts ( Galvanized ) ( Standard Make Conforming To Relevant Is With Latest Revision ) , Galvanizedflat Washersof Sizes ( Standard Make Conforming To Relevant Is With Latest Revision ) , H.V Cork Washers Of Sorts For Hv Bushing 38 Mm O.D ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) , L.V Cork Washersfor 12 Mmbush Rod With Corrospondiing Bush Cups ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) , L.V Cork Washersfor 16 Mmbush Rod With Corrospondiing Bush Cups ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) , L.V Cork Washersfor 19Mmbush Rod With Corrospondiing Bush Cups ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) , L.V Cork Washersfor 25Mmbush Rod With Corrospondiing Bush Cups ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) , L.V Cork Washersfor 32Mmbush Rod With Corrospondiing Bush Cups ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) , L.V Cork Washersfor 38Mmbush Rod With Corrospondiing Bush Cups ( Type Pc 70C Of Is 4253 ( Part-Ii ) 1980 ) , Oil Seal Rings ( O-Rings ) For Lv / Hv Bush Rods 12 Mm Dia ( Standard Make Conforming To Relevant Is With Latest Revision Made Fromneoprene / Nitrile Rubber Grade Ba 60 Of Bs:2751 ) , Oil Seal Rings ( O-Rings ) For Lv / Hv Bush Rods 16 Mm Dia ( Standard Make Conforming To Relevant Is With Latest Revision Made Fromneoprene / Nitrile Rubber Grade Ba 60 Of Bs:2751 ) , Oil Seal Rings ( O-Rings ) For Lv / Hv Bush Rods19mm Dia ( Standard Make Conforming To Relevant Is With Latest Revision Made Fromneoprene / Nitrile Rubber Grade Ba 60 Of Bs:2751 ) , Oil Seal Rings ( O-Rings ) For Lv / Hv Bush Rods 25 Mm Dia ( Standard Make Conforming To Relevant Is With Latest Revision Made From Neoprene / Nitrile Rubber Grade Ba 60 Of Bs:2751 ) , Oil Seal Rings ( O-Rings ) For Lv / Hv Bush Rods 32 Mmdia ( Standard Make Conforming To Relevant Is With Latest Revision Made From Neoprene / Nitrile Rubber Grade Ba 60 Of Bs:2751 ) , Oil Seal Rings ( O-Rings ) For Lv / Hv Bush Rods 38 Mmdia ( Standard Make Conforming To Relevant Is With Latest Revision Made From Neoprene / Nitrile Rubber Grade Ba 60 Of Bs:2751 ) , Creep Tape 1” ( Standard Make Conforming To Relevant Is With Latest Revision ) , Cotton Cloth Soft, High Absorption Capacity Of Strandard Size , Fast Curing Epoxy Compound Sealent Adhesive ( M.Seal ) 50 Gram Pack , Strandard Epoxy Adhesive ( Resin 1 Kg + Hardener 800 G ) ( Araldite ) , Washing Soap Lifebouy Wheel / Rin Or Equivalent , Wood Saw Dust , Solder ( Lead / Soft Solder ) , Solderflux / Paste / Liquid50 Gram Pack , Transformer Oil Fresh ( Conforming To Is 335 And Shall Be Clear And Transparent Free From Any Suspended Matter ) . Transformer Oil , Lpg Gase Cylinders ( Commercial 19.5 Kg ) , Lpg Gas Cylinder Refilingcommercial , Oxygen Gas Cylinders Oxygencapacity9 Kg , Oxygen Gas Cylinder Refilling Oxygen Capacity 9 Kg , Press Card Board Wedges Of Sizes 4Mm / 16Mm1½x3, 1.5X1.75 , Aluminium Sleeves 2Mm For Ht Coils Joints , Aluminium Sleeves 4Mm For Ht Coils Joints , Coppersleeves 4 Mm For Ht Coils Joints , Coppersleeves 6 Mm For Ht Coils Joints , Clear Varnish Paint , Copper Barzing Rods Of Latest Is Specification And Size , Brazing Flux In Grams Of Latest Is Make , Wooden ( Kail Wood ) Ltbobinfor Wind Of Lt Coils Compatable For Lt Windingfor25 To 1000Kva Transformer , Wooden ( Kail ) Htbobinfor Wind Of Ht Coils Compatable For Ht Windingfor1000kva Transformer , Alminium Strip ( Shim ) 0.15 -3.00 Mm Thick For Lt Coils Of Sizes For 25 Kva / 63Kva / 100Kva / 200Kva / 250 Kva / 300 Kva , Copper Strip ( Shim ) 0.15 -3.00 Mm Thick For Lt Coils Of Sizes For 300Kva / 400Kva / 500Kva / 630Kva / 1000 Kva , Ht Tap Rolls , Filter Plant Pipe 1½ , Silica Gel , M 4 Grade Crgo Silicon Steel Core Lamination As Per Is 3024 Of Sizessuitable For25 Kva / 63 Kva / 100 Kva / 200Kva / 250 Kva / 300 Kva / 400 Kva / 500 Kva / 630 Kva / 1000 Kva , Vaccume Oil For Filtration Plant , Coolent For Diesel Generator , Brass Gate Valve 1.5 Inch , Ms Pipe Plug For 1.5 Pipe. , Safety Knife For Precision Paper Cutting , Pliers 8 Inch , Scissors 10 Inch High Carbon Steel , Double End Spanners , Single End Spanners , Grease , Drop Forge Adjustable Wrench Chrome Plated , 14 Inch Adjustable Wrench For Gi Pipes. , Files Coarse , Files Fine , Fabric Sanding Paper 4 Wide 250 Grit. , 16 / 18 Inchesfloorwipers ( Heavy Duty ) , Jio Recharge For Jio Fiber Standard Pack Data Already Installed At Sub Division Workshop For Maintaining Jkpdd Transformer Damage Portal30 Mbps , Combo Steel Stancil Of Numericals And Alphabits ( Size A6 ) 10.5 X14.85 Cms Having Alphabita ( A-Z ) And 0 To 9 ) Numericals And Symbols ( -, + )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Jammu And Kashmir View Result →
13.
Power #9963914 AOC
Procurement Of Spares For Generator Relay Panel Of Unit Iii Procurement Of Spares For Generator Relay Panel Of Unit-Ii , Procurement Of Spares For Generator Relay Panel As Per Technical Specification Enclosed. Numerical Differential Protection Relay Make: Schneideror Its Equivalent Type: Power Logic P7t Or Its Equivalent Supply Of1400mmwidth, Fabric Strength 1750Kn/M, 5 Ply,Cover Thickness5/2,Nylon/Nylon Conveyor Belt As Per Technical Specification Enclosed. , Hand & Electrically Reset High Or Low Burden Tripping Relay Make: Geor Its Equivalent Type: Mvaj205or Its Equivalent Model: Mvaj205la1000a Or Its Equivalent Supply Of1400mmwidth, Fabric Strength 1750Kn/M, 5 Ply,Cover Thickness5/2,Nylon/Nylon Conveyor Belt As Per Technical Specification Enclosed. , Hand & Electrically Reset High Or Low Burden Tripping Relay Make: Geor Its Equivalent Type: Mvaj205 Or Its Equivalent Model: Mvaj205la1006a Or Its Equivalent Supply Of1400mmwidth, Fabric Strength 1750Kn/M, 5 Ply,Cover Thickness5/2,Nylon/Nylon Conveyor Belt As Per Technical Specification Enclosed. , Single Element Relay Make: Geor Its Equivalent Type: Mvaam11 Or Its Equivalent Model: Mvaam11b1cj5516a Or Its Equivalent Supply Of1400mmwidth, Fabric Strength 1750Kn/M, 5 Ply,Cover Thickness5/2,Nylon/Nylon Conveyor Belt As Per Technical Specification Enclosed. , Two Element Relay Make: Ge Or Its Equivalent Type: Mvaam21 Or Its Equivalent Model: Mvaam21c1aa2580a Or Its Equivalent Supply Of1400mmwidth, Fabric Strength 1750Kn/M, 5 Ply,Cover Thickness5/2,Nylon/Nylon Conveyor Belt As Per Technical Specification Enclosed. , Voltage Selection Relay Make: Geor Its Equivalent Type: Mvapm32 Or Its Equivalent Model: Mvapm32d1aa2001a Or Its Equivalent Supply Of1400mmwidth, Fabric Strength 1750Kn/M, 5 Ply,Cover Thickness5/2,Nylon/Nylon Conveyor Belt As Per Technical Specification Enclosed. , Numerical Overcurrent Relay Schneider Make Powerlogic P3u20, 8Di/8Door Its Equivalent
Contract Date: Apr 09, 2026 Contract Value : 10.80 Lakh
Boards / Undertakings / PSU No of Bidders 2
16.
Defence #9609242 AOC
Tender For Repair, Maintenance And Replacement Of Ht Cables, Gods, Vcbs, Rmus, Transformers And Connected E And M Items At Af Stn Suratgarh; 1 Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles,struts, stays etc and getting out all as specified and as directed by Engineer-In-Charge. 2 All as per item No. 1 here-in-before but in PCC/floor/road 3 All as per item No. 1 here-in-before but depth exceeding 1.5 metre and not exceeding 3 metre 4 Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified. 5 Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all asspecified. 6 M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techniqueand necessary machine or manually without damage nearby electric cable, water pipe line etc including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure and sealing the end of pipe complete all as specified and directed. 7 M&L for laying GI Tubing light grade 100 mm dia for cable potection in road/ floor all as specified and directed 8 Supplying and laying ofsize 90 mm dia (OD-90 mm & ID-75 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 9 Supplying and laying ofsize 120 mm dia (OD-120 mm & ID-103 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 10 Taking out HT/ LT cable of any size/ description from trenches/ floors/ road/ wall/ pipe/ pole and removing & reusefrom site incl making good the disturbed surfaces to match with existing surface all as directed. 11 Relaying/ Labour only for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to panel board/ VCBat existing places or provided by MES forcarrying to other location, upto 33000/11000 volts grade heavy duty cable with XLPE/PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed of size upto 300 sqmm 3 core obtained from item No.10above with required aluminium cable lugs, heat shrink joints specified and directed.Note:The cableJoints and protection pipe and Earth work (if cable laying new rout)shall be meausred seperatly. 12 Supply, laying in trenches/ with pole, jointing and testing of HT 11 KV rated XLPE insulated, PVC bedded earth system stranded aluminium conductor cable 3 core, 95 Sqmm inclusive all incoming and out-going electric connections, complete all as specified and as directed. 13 All as per item No 12 above but of size 3 core 120 sqmm 14 All as per item No 12 above but of size 3 core 150 sqmm 15 All as per item No 12 above but of size 3 core 300 sqmm 16 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 17 All as per item No 16 above but joint of size 120 to 185 sqmm 18 All as per item No 16 above bu joint of size 240 to 300 sqmm 19 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 20 All as per item No 19 above butjoint of size 120 to 185 sqmm 21 All as per item No 19 above butjoint ofsize 240 to 300 sqmm 22 S&F in replacement cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed. 23 All as per item No22 above but straight through joint of size 120 to 185 sqmm 24 All as per item No 22 above but straight through joint ofsize 240 to 300 sqmm 25 S&F in replacement cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 33 KV, 3 core 300 sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed. 26 All as per item No 25 above but indoor type joint 27 All as per item No 25 above but straight through type joint 28 Supply and fixing cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.90m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x20cm x30cm block complete all as specified and as directed by Engineer-in-Charge. 29 Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line including taking down existing cracked/unserviceable pin type insulator complete all as specified and directed. 30 S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator/ polymer including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33KV grade complete incl taking down old/unsv all as specified and directed. 31 Supply and fixing disc type insulators, porcelain vitreous white brown or green, 145mm hight and 255mm dia ball and socket type, single disc assembly for tension with tension clamps for conductor having working pressure 120 KN for11000 Volts /33000 volts (use suitable string ) with highest voltage capacity 12 KV including taking down existing cracked/unserviceable disc type insulator complete all as specified and directed. 32 Taking down old U/S GO switch any type and size from HT 2/4 poles structures. 33 S & FGang operated switch outdoor type 11000 Volts, 200 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 9 Nos., channel, knife blades, GI pipe medium grade 25 mm dia for operating mechanism worked from ground level , locking arrangement with handle all as specified. 34 S & FGang operated switch outdoor type 11000 Volts, 400 Amp capacity tripple pole machenically operated suitable for operation from ground level and for vertical mounting complete with HT insulators 12 Nos. with dropout fuse set, channel, knife blades, GI pipe medium grade 40 mm dia for operating mechanism worked from ground level, locking arrangement with handle all as specified. 35 All as per item No 34 but for 33 KV 400 Amp, operating horizontal direction incl taking down old/unsvall as specified and directed 36 S&F in replacement expulsion fuse unit single pole mounted on insulator & steel frame complete with fused barrel (drop out fuse) suitable for 11 KV for current rating upto 20 Amp incl taking down old/unsv fuse unit complete all as specifed and directed. 37 S&F in replacement HT 33 KV outdoor type dropout fuses double stack channel type complete with insulator of rating up to 400 Amps incl taking down old/unsvcomplete all as specified and directed. 38 Repairing / Servicing the Air break isolating switch HT 11 KV 200/400 Amps by replacingthe defective major spares parts including provn of minor bolts nuts etc all as specified and directed.Note: Major spare parts will be measured & paid seperately under relevant items of Sch-A 39 Supply only Male contact/ moving Contact Blade 40 Supply only Female contact/Fix Contact Jaw 41 Supply only Tinned copper Flexible jumper 200A/400 A 42 Supply only MS jumper carrier 43 Supply only Back Connector plate 44 Supply only Petroleum Jelly 45 Dismantling/ Taking down old unserviceable lightning arrestor 11 KV from HT 2/4 poles structures. 46 M&L for HT 11 KV lightening arrestor expulsion type having discharge capacity of 65 KA, suitable for 11 KV HT line includng making connection with existing GI earth wire. 47 S&F of lightning arrestors expulsion type complete with all fittings, suitable for 33 KV grade transmission class, discharge capacity 65KA including brackets, clamps, nuts washers and connecting to 4 mm dia GI earth wire including taking out old unservicable lightining arrester allcomplete all as specified and directed. 48 Supply and fixing of Jumper for HT OH Lines 33/11 KVbus system to GOD and GOD to DO Fuse unit with jumper made of aluminium conductorinsulated with colour coding, (Red Green , Blue) with all conneted item i.e nut bolt, U G clamps etc up to length of size 3 to 5 Mtr all as specified and directed by Engineer -in-charge. 49 Dismantling concrete poles/ struts of any size complete all as specified and directed. 50 Demolition of concrete (coping of PCC/ GI pole/ Road) of any description and in any position 51 Supply and erecting in true vertical position steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including drilling of holes of required size and nuts for fixing of cross arms, painting with two coats of aluminium paint over a coat of red oxideand two coats of black bituminous paint for portion embedded in concrete, painting five black and white bands at lower portion of pole each of 300 mm height at 300mm spacingcomplete all as specified and directed.(Note : Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately under respective items of Sch A). 52 PCC 1:2:4 (nominal mix) type B-2 using 40mm graded crushed stone aggregate, as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed. 53 PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed. 54 M&L for PCC 1:2:4 type B1 using 20mm graded aggregate in coping of size (0.65x0.55x0.45) Mtr for PCC/RCC/Steel tubular pole complete with 10mm thick cement plaster CM 1:4 on coping surface complete all as specified and directed. 55 M & L for scrapping of old painted surfaces of electric pole covered by dust and other depositedmaterials by cleaningwith wire cup brush on drill /grinderfromsteel tubular pole of length upto 11 metres including cross arms,bracing, clamps etc and painting with one coat of Epoxy zinc phosphate primer and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, all as specified & directed by Engineer-in-Charge. 56 M & L for scrapping existing deteriorated complete removal of old paint bywith wire cup brush on drill /grinderfrom the steel tubular 2 pole structure of 9.0-11.0 mtr height above ground levelwithout removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative existing strip (white and black or Red and yellow )of 30 cm height each, including one coat ofEpoxy zinc phosphate primer to the remaining part of pole (i.e above 1.50 mtr height) and its cross arms, bracing, support and all steel members complete all as specified and directed. 57 All as per Ser item No. 56 above but for 4 pole structure. 58 All as per Ser item No. 56 above but for 6 pole structure. 59 Dismantling ACSR or AAC conductor complete all as specified and directed. 60 Supply andfixing aluminium conductor, steel reinforced (ACSR) of following sizes as in overhead conductor including fixing aluminium tapes for binding complete all as specified and directed: -(a) 6/1 x 3.0- Ferret (b) 6/1 x 2.59- Weasel(c) 6/1 x 2.11- Squirrel Note: The weight of the conductor shall be determined as stipulated in Preamble (b) & (c)on Page 384 of SSR-2010 Part-II (Rates). 61 M& L for Stringing of ACSR conductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 62 M& L for Stringing of GI cradle Guaredconductor any size to HT/LT over heads lines, streching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as specified and as directed by Engineer-in-Charge. 63 M&L for restraining of GI wire of any size on pole after disconnecting all binding on cross arms and redoing all bindings providing required T&P all as specified and directed 64 Supply and fixing PVC moulded LT Line separator suitable for 4 lines OH system. Make- Denson/Mex-well/JB/Jaipuriya brothers 65 Surface excavation over the areas around the substations not exceeding 45 cm depth and averaging 30 cm deep and getting outspoil inhard & dense soil including levelling the surface. 66 M&L forscreened river sand/ tibba filling on the levelled ground surface/ducts in sub stations/below 2 pole & 4 pole structures etc 67 M&L stone aggregate of size 35 to 40mm spreading over sand layerin the substation areas including proper leveling all as directed and shown at site. 68 M&L stone aggregate of size 20 to 25mm spreading over sand layer in the sub stations areas including proper levelling all as directed . 69 M&L taking out spreadedaggrgate of any size &sieving the aggrgate & dust/ sand & relaying the aggregate after sieving in the sub stations 70 M&L brick work with sub class B brick straight cured on plan exc 6m mean radious built in cm 1:4 71 Rendering/cement plastering 15mm thick on fair faces of brick work or concrete surfaces in Cement mortor 1:4 finished even and smooth without using extra cement 72 S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk),forming holes of Fe 410-W (Gde E- 250) quality without any attachmen use for cable duct cover at substncomplete all as directed. 73 M&L for replacement of earth pit chamber of size 300 x300 mm (internal dimensions) and 450x450mm(External)with PCC 1:3:6 type C-1 , RCC 1:2:4 type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick with 12 mm dia MS hook of suitable size and shape for lifting and MS angle iron frame 50 x 50 x 4 mm including GI funnel with wiremesh complete all as specified. 74 Material and labour for fixing of display Board of 60cmx30cm forearth pit made out of 2 mm thick MS sheet welded on angle iron legs 0.75 mtr long (02Nos) of size 40x40x6mm duly embeddedin PCC block 1:2:4, type B-1, using gradedcrushedstone aggregate, of size 23x23x30cm fixed in ground including necessary earthwork. Display Board shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in- Charge. The following is to be written on the board:- (a) Earth Pit No. -(b)Connected To -(c) Checked on -(d) Next due date.-(e) Ohmic Value 75 Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) in and around electrical sub stations, two/four pole structures and removing rubbish to a distance upto 50 metres outside the periphery of the area, complete all as specified and as directed by Engr-in-Charge. 76 Supply and fixing of synthetic insulating matsuitable for 11 KV installation of size 1.00 m x 2.00 m and 25mm thick (ISI marked) complete all as specified and directed. 77 Supply and fixingEarthing dischard rod(ISI Marked), extendable upto 18 feet height with rubber hand grip and suitable size copper wire suitable for working with 11 KV HT lines complete all as specified and directed. Make: Jaipuria/Rashtriya Electricals 78 Supply and fixAluminium thimble/lugs suitable for 50 sqmm to 95 sqmm XLPE cable all as specified and directed. 79 Supply and FixAluminium thimble/lugs suitable for 120 sqmm to 185 sqmm XLPE cable all as specified and directed. 80 Labour for disconnecting LT/HT cable of any size from structure/pole/transformer for finding fault, M&L for defect rectification LT/HT cable laid in trenches or any location by liacting fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 12 hours after notification, failing to which Rs500/- per day complaint will be recoverd. fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quioted rate all as specified and directed by Engineer-in-charge.Note: joint kit will be measured seperately in appropriate item in this schedule 81 Labour only for disconnecting LT/HT cable of any size from pole (height 7.5 to 9 mtr) /transformer/panel and re-connecting ofcable at both endafter removing carbon /burnt insulation part of cable by cutting refixing cable withnew cable lugs . The entire repair work to be completed with in 06 hours of instruction from Engr-in-charge all as specified. Note:- Complaint will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified with in 06 hours after notification, failing to which Rs 500/- per daywill be recoverd per complaint. 82 M&L for earthing complete with GI earth plate 600x600x6mm thick electrode and 32x6 mm GI strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to GI strip earth lead by means of bolts, nuts, check , nuts and washers of galvanised iron or steel all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note: GI stripbeyond 7.5Mtr length from earth electrode shall be measured and paid separately). 83 All as per item No 82 above but with 4 mm dia GI wire as earthing lead andGI protection pipe 20mm dia medium grade. 84 M&L for earthing complete with copper earth plate 600x600x3.15mm thick electrode and 20x3 mm copper strip as earthing lead buried directly in ground (Earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground connected to copper strip earth lead by means of bolts, nuts, check , nuts and washers of copper all as shown on electrical plate no. 3 including 40 mm dia medium grade GI protection pipe, 20mm dia GI medium grade watering pipe, funnel, wire mesh , charcoal dust, PCC pit and 50mm thick RCC cover, earth work in any type of soil connected to earthing test point complete all as specified and as directed.Note : Copper strip & GI pipe 40mm dia beyond 7.5mtr length from earth plate shall be measured & paid separately under respective item) 85 S&F earthing strip 32x6mm GI fixed to wall/pole/buried in ground /drawn in pipe complete. 86 S&F earthing strip 20x3.0 mm copperfixed to wall/pole/buried in ground /drawn in pipe complete. 87 S&F GI wire 4mm dia iron fixed to wall/pole/buried in ground /drawn in pipe complete. 88 S & F Danger notice plate for HT poles size 1.6 mm thick mild steel sheet vitreous enemelled white letter figures and converntionl skull and bones maked in red colour with MS clamp of flate iron 25X3mm size, bolts, nuts, size of plate 25 X20 Cm complete all as directed by Engineer-In-Charge. 89 Dismantling unserviceable any size of cross arms from pole /structures/anti-climbing device etc complete allas specified and directed. 90 M&L for MS work confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer all as directed by Engineer-In-Charge. 91 M&L for anti climbing devices, spike type fabricated out of MS bars (Round, square and flat) including nuts, bolt, washers and welding in two halves made to shape to suit the cross section of the pole including painting etc complete all as specified and as directed. 92 Cutting/trimming of tree branches under OH LT/HT electric line including cleaning upto 3.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers smal bushes etc of under OH line upto 60 mitre each span complete all as specified and directed.Note: Materials/T&P like Axies, Daw, rope and the like will be provided by the contractor without any extra cost to the Govt. 93 M&L for stay assembly complete with MS stayplate 300x300x6mm thick galvanized stay rodnot less than 20mm dia, 2.15 M long galvanized stay bow, galvanized thimble,stay clamp etc. all as shown in electrical plate No1of SSR part-I.Note:- Excavation,earthwork,cement concrete loop type insulators and stay wire shall be measured and paid separately under relevant items. 94 M&L for Galvanised stay strand, size 7/4mmcomplete. 95 M&L for loop insulator, vitreous, porcelain, white, brown or green, large size with overall dimensions 50x140mm clearance of hole 25.5 mm complete. 96 Overhauling/ servicing /calibration of HT VCB 400/630 Amps 33 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v)Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare parts shall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 97 Overhauling/ servicing /calibration of HT VCB 400/800 Amps 11 KV of any make by carrying out following job:-(i) Taking out VCB trolly from the panel board.(ii) Removal of dirt,dust & carbon particles by air blower(iii) Cleaning of all moving & fixed contacts of VCB with dry cloth & CRC solution and greasing of moving contacts & gears.(iv) Checking and setting of VCB ON/OFF operation mechanism through TNC & push button and triping relay and adjust the trip setting.(v) Checking tightness of all control wires.(vi) Checking leakage in vacuum interrupter by Hi-Pot test.(vii) Assembly of trolly and testing complete.(viii) Servicing shall be got carried out by authoised rep of the VCB manufacturer and the service engineer submit a service report of each VCB with detais of settings perameter.Note: Spare partsshall be undertaken through authorised service centre of OEM as directed by the Engineer-in-charge. 98 Supply and fixing in replacement microprocess numerical relay for 33/11 KV VCB tripping system ( 03 Over Current/02 O/C , 01 Earth Fault and high set instantaneous protection in single unit) suitable for opration on 24V DC-110V DCall as per Model No CGI14N/CGI4C of Make: Crompton Greaves or equivalent in AREVA(Note:ifExisting relays are of Electromagnetic type, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 99 Supply and fixing in replacement Ammeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh (Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 100 Supply and fixing in replacement voltmeter for HT panel Square dial of size 100 mm digital type complete all as specified and as directed.Make : AE/Rishabh(Note: Existing meter analough type and large in size, hence any modification in the wiring,and panel sheet enclosure is deemed to be inclusive in the scope of work). 101 M & L for Vaccum Interrupter type WL-33379 or as per exixtingsuitable for 11 KV VCB Panelcomplete all as specefied and directed. 102 M & L for Isolating contact assembly 400/800 Amps with complete set of contact (set of six) suitable for 11 KV VCB Panelcomplete all as specefied and directed. 103 Supply and fixing in replacement indicator lamp assembly 24V DC in (Red,Yellow, White, Green & Blue colour) for HT panels complete all as specified and as directed. 104 Supply install, testing and commissioning in replacementof Power packunit input voltage 90-270 Volts and out put voltage 24 Volts DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unitcomplete all as specified and as directed 105 Supply install, testing and commissioning in replacement of Power packunit input voltage 110 Voltage and out put voltage 24 Volt DC having4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unit complete all as specified and as directed 106 Supply and fix Motor cut off switch complete all as specified and directed 107 Supply and fix ZZ Switch complete all as specified and directed 108 Supply and fix HRC Kit kat fuse 2A, 4A,6A ,10A & 20 A complete all as specified and directed 109 Supply and fix Closing coil 24V DC complete all as specified and directed. 110 Supply and fix Tripping coil 24V DC complete all as specified and directed 111 Supply and fix of Multifunction meter (V,A,P,PF) for 11 KV VCB as per existing sample complete all as specified and directed. 112 Supply and fix of Big gear and small gear set complete all as specified and directed. 113 Supply and fix of TNC switch 11 KV/33 KVpanel complete all as specified and directed. 114 Supply and fix Segment gear complete all as specified and directed. 115 Supply and fix of 11 KV Spring charging motor 220V AC/DC complete all as specified and directed. 116 Supply and fix Motor & Gear assembly 110V DC and 220 ACfor 11 KV VCB Panelcomplete all as specefied and directed. 117 M&L for painting to VCB,Fire stand post ,duct plate etc atinstallations with two coats of synthetic enamel paint after making the suface free from oil/grease/rust and applying a coat of red oxide primer complete including writing details as per directed like as SM Nos/feeder detail etc. all as specified and as directed. 118 S & F in repair Aux relay Buch/WTI/OTIfor 11 KV VCB panel ,Auxiliary supply 24Volt DC as per existing complete all as specified and directed. 119 S & F Cast resin type 11KV VCB three phase current transformer having ratio 100+50/5+5Aas per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second 120 S & f 11KV VCB three phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level 35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156 121 S&F in replacement HT fuse wire upto 60 amp asper site requirement mounting on insulator of 2 Pole/4 Pole structure complete with fused barrelfor 11 KV complete all as specifed and directed. 122 Disconnecting, opening of HT Capacitor bank of any description and any make of rating 11 KV indoor capacitor switching APFC paneland outdoor capacitor bank type with automatic/manual control having output 2400 KVAR (Step rating proposed : 400 KVAR x 2+800 KVAR x 2 desired 0.99) for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etcand replacement of unserviceable parts with new one, reassembling the HT Capacitor Bankafter overhauling/ servicing and its testing complete all a specified and directed. Note:Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch A as supply only 123 Spply only HT HRC Fuses suitable for 11 KV, 400 KVAR complete all as specified and directed. 124 Spply onlyHT HRC Fuses suitable for 11 KV, 800 KVAR complete all as specified and directed. 125 Spply only NDVR Relay suitable for 400 KVAR step complete all as specified and directed. 126 Spply only Contactor coil 127 Spply only Copper bus bar 50x10 mm length 1 mtras per site requirement 128 Dismantling and taking down by removing HT and LT connection of indoor /outdoor type 11/0.433 KV transformer of capacity up to 200 KVA from existng platform/4 Pole/inside sub station Lowering the same carefully and shifting to other location within Air force station(both tech & resdential) as directed by Engineer-in-charge with and including re-installation by means of arrangement and testing and including additional/alterationfoundation according manufactures complete all as specified and directed . Note : (a) Installation of transformer , testing and connecting the both HT/LT cables , commissioning of transformer after checking voltage and loading at full load shall deemed to be included in quoted rates .(b) Contractor shall provide necessary tripod, chain & pulley, T&P, etc for transportation, the rent and foundation for additional/alteration shall deemed to be included in the quoted rate. 129 All as per srl item No128, abovebut capacity of transformer more than200 KVA andupto 500KVA complete all as specified and directed . 130 Repair to distribution transformer step down 11/0.433 KV indoor/outdoor type of capacity 100 KVA to 250 KVA, after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete, taking out the core and winding by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper/aluminium wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, varnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engineer-in-Charge. Note :- (i) Winding wire for making of coils, HT/LT bushes, new transformer oilwill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 131 All as per Srl item No 130 above but of capacity 11 / 0.433 KV, above 250 KVA upto 630 KVA complete all as directed. 132 S & F in replacement brass terminal rod with nuts , boltswasher and bushing suitable for HT and LT side of the transformer of any make and capacity upto 200 KVA complete all as specified and directed . 133 All as per srl item No132, abovebut capacity of transformer more than200 KVA andupto 630KVA complete all as specified and directed . 134 S & F in replacement tap changing switch suitable for operation on 11/0.433 KV distribution transformer with tappings on 2.5% , 5% and 7.5% on requirement basis for upto 630 KVA capacity transformer complete all as specified and directed . 135 Supply and Filling in replacement superior quality silica jel inside the breather assembly and fixing properly with transformer complete all as specified & directed. 136 S & F in replacementoil valve for drain out/filling in screwed both ends with iron wheel head suitable for transformers up to 200 KVA capacity complete all as specified anddirected. 137 All as per srl item No 136, abovebut capacity more than 200 KVA andupto 630 KVA complete all as specified and directed . 138 M & L for fabrication HT / LT side box covers made of bakelite sheet10 mm thickness with proper nuts bolts incl cutting sheet to required size , drilling holes for nuts/bolts etc complete allas specified and directed. 139 S & F in replacement oil temperature gauge 0 -120 degree analogue dial type for transformer complete all as specified & directed 140 M & L for filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength/ insulation value upto65 KV/40KV (RMS) atstandardgap of electrodes 2.5 mm for one minute in 33 KV/11 KV transformer capacity 3 MVA TO 5 MVA including insulation testing of oil with help of suitable equipments before and after dehydration including BDV Test compete all as specified and directed.Note:(i) Contractorwill have to arrange the dehydration machine and transformer oil dielectric strength testing equipmentas mentioned and same shall be deemed to be included in the item rate quoted.(ii) Test result of transformer oil before and after dehydartion is required to submit by contractor duly signed by all concerned. (iii) The contractor shall ensure that the conservator tanks are full to its level before commencement of dehydration process. (iv) Additional quantity of transformer oil if any required for making the oil level upto the requirement in transformer shall be measured and paid separately as supply and filling but its cost of heating shall be deemed to be included in the rate quoted for above item. 141 Supply and filling transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not be less than 70 KV at 2.5mm gap for reduced level of transformer due to evaporation/ leakage/losses due to dehydration in HT33 KV transformer/HT 11 KV AVR transformer/11 KV distribution transformer all as as specified and directed. 142 Supply only super enameled copper conductor wire of suitable gauge and size as per requirement for rewinding of 33/11/0.433 KV power/distribution transformer complete all as specified and directed . 143 Supply only super enamelled aluminium conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformer complete all as directed. 144 Supplying and fixing in replacement, Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers. 145 All as per Serial item No144 here-in-before butcapacity 200 KVA to 315 KVA 146 All as per Serial item No 144 here-in-before but capacity 400 KVA to 630 KVA 147 Supplying and fixing in replacement, Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 160 KVA andconnecting electrically and mechanically, testingcomplete all as specified and directed. Note.The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washers andsuitable size pad type bus bar almuminium and nut bolt washers and reconnection 148 All as per Serial item No 147 here-in-before but200 KVA to 315 KVA 149 All as per Serial item No 147 here-in-before but 400 KVA to 630 KVA 150 Supplying and fixing in replacement,all unserviceable gasketafter disconnecting electrically and mechanically for indoor/outdoor transformer of capacity upto 200 KVA andre-connecting electrically and mechanically, testingcomplete all as specified and directed. Note.(i) The rates quoted is deemed to be included the cost of necessary labour charges for draining out & re-filling transforer oil,opening of top cover by unscrewing nut, bolts washersetc. (ii)Joint shall be leak proof and any leakage noticed after repair work shall be rectified by the contractor without any extra cost to the deptt. 151 All as per Serial item No 150 here-in-before butmore than 200 KVAand up to 630 KVA 152 S & F in replacement, Silica Gel Breather assembly including vent pipe and Silica Gel for indoor/outdoor transformers,capacityupto 200 KVA complete all as specified and directed. 153 All as per Serial item No152 here-in-before butcapacity more than 200 KVA and upto 630 KVA 154 Supply and fixing in replacement 3mm thick Sheet glass (each not exceeding 0.9 Sqm) ordinary quality and glazing with oil putty on cabin of OTI and WTI gauge of transformer upto capacity 630 KVA complete all as specified and directed. 155 Supply and fixing in replacement thermometer of transformer upto capacity 630 KVA complete all as specified and directed. 156 M & L for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint (heat resistant type)according to to IS colour code by spray machine including writing MES /SM No. in capital letters of suitable size on body for capacity upto 160KVA transformer outdoor/indoor complete all as specified and directed 157 All as per item No: 156 but capacity above 200 KVA and upto 630 KVA. 158 Repair to distribution Power transformer 33/11 KV outdoor type of capacity 3 MVA to 5 MVA , after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oilfrom the housing complete,replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of all gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable HT bushes, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the Transformer and TTRtesting with complete all as specified and directed by Engineer-in-Charge. Note :- Transformer oil /Winding wirewill be measured & paid seperately(ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation. 159 Supply and fix inreplacement WTIrelay suitable for 3.15 MVA /5 MVA transformer control panel completeall as specified and directed by Engr-in-charge. 160 Supply and fix inreplacement OTI relay suitable for 3.15 MVA/ 5 MVA transformer control panel complete incl taking down unsv all as specified and directed by Engr-in-charge. 161 Supply and fixinreplacement Mastertripping relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 162 Supply and fixinreplacement Differntial protectionrelay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 163 Supply, fixing and testingin replacement Buchholz relay with display suitable for 3.15 MVA/5 MVA transformer control panel complete incl taking down unsvall as specified and directed by Engr-in-charge. 164 Supply and fix inreplacement Over/Under voltage protectionrelay with display suitable for 3.15 MVA/5 MVA transformer/ 33 KV VCBcontrol panel complete with testing and calibrationincl taking down unsvall as specified and directed by Engr-in-charge. 165 Supply & Fixmarshaling box complete with all sensor/Meter/indicatorfor protection of winding temprature , oil temprature etc suitable for 5 MVA/3MVA Transformeror as per existing incl connection andtaking down unsv all as specified and directed. 166 M&L for overhauling of the 11 kV Automatic Voltage Regulator (AVR) involves a comprehensive inspection, cleaning, testing and restoration process to ensure reliable performance and accurate voltage regulation. The scope includes the following :-(a) Initial Inspection: Visual and mechanical inspection of the AVR and associated components to assess overall condition and identify faults or degradation.(b) Dismantling: Safe removal and disassembly of the AVR unit including checking connections, terminals and internal assemblies.(c) Cleaning: Removal of dust, oil, moisture, and other contaminants using appropriate cleaning agents and techniques.(d) Component Testing: Electrical testing of control circuits, sensing mechanisms and regulating components to detect wear, drift or failure.(e) Replacement of minorParts: Replacement of defective or worn-out components such as resistors, capacitors, relays, or control cards with compatible, high-quality spares. 167 (f) Reassembly and Calibration: Reassembling the AVR and performing calibration to manufacturer specifications for optimal voltage regulation performance.(g) Final Testing: Functional testing under simulated or actual load conditions to verify stability, response time and output regulation.(h) Reporting: Preparation of a detailed service report including findings, actions taken, test results and recommendations.Note :- (i) Restore the AVR to its original working condition with improve efficeincy andreliable operation of the 11 KV system.(ii) The above work shall be carried out by the authorised manufacturer and rate for the same are included in this item. Nothing shall be paid extra on this account. Note :- Following Major spare parts will be measured & paid seperately 168 Supply only AVR Carbon roller assemblycomplete all as specified and directed 169 Supply only tag and tail assey AVRcomplete all as specified and directed 170 Supply only B4c limitt switchcomplete all as specified and directed 171 Supply only PCB sensing relaycomplete all as specified and directed 172 Supply only Motor 40 KG with Gearcomplete all as specified and directed 173 Supply only Delta change flip flopcomplete all as specified and directed 174 Supply only TDR 240 V AC complete all as specified and directed 175 Supply only Aux Contactorcomplete all as specified and directed 176 Supply, installation, testing and commissioning of 11 kV, 630 Amp, 3 Pole, Outdoor Type Load Break Switch (LBS) with manually operated gang mechanism, suitable for breaking load current under normal service conditions, complete with insulators, arcing horns, operating mechanism, earth blades, padlocking arrangement and all other necessary accessories for safe and efficient operation ,The LBS shall be mounted on hot dip galvanized steel support structure duly fabricated with base frame, operating pipe, crank and handle, including providing and casting of cement concrete foundation in 1:3:6 type C-2 (using 40 mm graded stone aggregate) with necessary excavation, formwork, curing and finishing smooth, including grouting of bolts and painting of steel structure with two coats of aluminium paint over one coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
Contract Date: Feb 16, 2026 Contract Value : 31.31 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
17.
Educational and Research Institute #9580422 Technical Bid
Tender For Purchase Of Lab Equipment , Chemistry Department , Heating Mantle 500Ml: Capacity: 500Ml, Suitable For Laboratory Glassware Such As Round-Bottom Flasks. Temperature Control-Adjustable Heating Settings For Precise Temperature Regulation. Heating Element: Uniform Heating With A Built-In Resistance Wire, Ensuring Even Heat Distribution. Outer Material: Durable, Heat-Resistant Fiberglass Or Aluminum Casing For Safety. Power Supply: Typically Operates On 110V Or 220V, , Heating Mantle 2 Litre: Capacity: 2 Litre, Suitable For Laboratory Glassware Such As Round-Bottom Flasks. Temperature Control-Adjustable Heating Settings For Precise Temperature Regulation. Heating Element: Uniform Heating With A Built-In Resistance Wire, Ensuring Even Heat Distribution. Outer Material: Durable, Heat-Resistant Fiberglass Or Aluminum Casing For Safety. Power Supply: Typically Operates On 110V Or 220V, , Magnetic Stirrer With Hot Plate Digital: Magnetic Stirrer With Heating And Ceramic Heating Plate. Temperature Range- Ambient +10°C To 250°C, Temperature Accuracy-±0.5°C Or Better, Electronic Speed Control, The Max Speed Is 1500Rpm.,Stainless Steel With Ceramic Coated Hotplate , Chemical Resistant And Scratch Proof,Fixed Safety Circuit Up To 500 °C Hot Top Indicator,External Temperature Sensor With Control Accuracy Of ±0.5°C Exact Temperature Setting Via Digital Display, Power Supply-220 Volts / 50 Hz, , Hot Air Oven: Temperature Range- Ambient +10°C To 250°C, Temperature Accuracy-±1°C Or Better, Capacity-95L, Display Of Sv & Pv, Construction- Double Walled, Inner Chamber-Stainless Steel, Exterior-Powder Coated Steel Sheet, Insulation-Ceramic Wool Insulation, Shelves-Chrome Plated Wire Mesh Cable Trays (Removable), Door-Insulated Solid Door With Spring Latchp, Door Gasket, High Temperature, Silicone Rubber Gasket, Safety-Over Temperature Thermostat, Power Supply-220 Volts / 50 Hz, Port Hole For Sensors & Data Monitoring, Digital Timer 99 Hours 99 Minutes. , Four Digit Electronic Balance: 0.0001G Resolution (0.1Mg), 4-Digit Electronic Weighing Balance Capacity: 220Gx0.1 Mg Scale, Readability 0.1 Mg, Linearity(+/-) 0.2Mg Calibration Internal, Accuracy 0.1Mg, Pan Size 90 Mm. Warranty 3 Years , Rotary Shaker: For Shaking Of Solutions In Erlenmeyer Flasks From 100 Ml To 500 Ml. Controllable Speed Up To 250 Rpm , High Speed Centrifuge Machine: Centrifuge Machine (8X15 Ml), Speed 15000Rpm. Multistep Step Regulator With Heavy Duty Motor, Durable Material Vaccum Rubber Feets, Balanced Abs Head For Vibration Free Movement. , Hydrothermal Autoclave Reactor: Stainless Steel Autoclave With Teflon Lining. Capacity 250 Ml , Dimmerstat/Auto Transformer: 4A, 300V Close/Variac/Dimmer/Auto Transfromer/Single Phase/Maximum Load 4Amp Volt 0-300Volt , Stop Watch: Lab Stop Watch 60 Second Timer Countdown Clock Analog-Should Be Able To Measure A Minimum Of 1 Second And A Maximum Of 1 Hr- , Hot Air Gun: 1800W Hot Air Heat Gun For Lab Use. Working In The 230 V Ac, , Uv Lamp Chamber For Tlc : Three Lamp With Wavelength - 265, 340 And 380 Nm , Uv Lamps For Tlc Checker: 254 Nm, 265, 340 And 380 Nm , Filters Li, Ca, K And Ba For Existing Flame Photometer: , Magnetic Stirrer With Hot Plate (Manual): Magnetic Stirrer With Hot Plate 2 Ltr, (Manual) , Rectangular Water Bath: Rectangular Water Bath With 12 Holes, With Concentric Rings With 12 Mm Diameter , Multipurpose Electronic Digital Weighing Balance: Battery Powered Weighing Balance, Max 600 G With An Error Limit Of 0.01 G., With Lcd Display, Units Conversion Should Be Possible (Kg, G,) With Taring Facility , Thermostatic Water Bath: Voltage: 220 V, Frequency: 50 Hz, Power Consume: 1 Kw, Capacity: 20 Liters, Tank Open Dimensions: 49 X 30 X 15 Cm Or More, Accuracy: +- 0,1 Degree C Technical Specifications: High Accurate Temperature Controller With Digital Readout Temperature Regulable From Room Temperature Up To 99ºc , Melting Point Apparatus Manual Temperature Up To 350 Degree , Zoology Department , Insect Storage Box : Size 45 X 30 X 7.5 Cm Teakwood Frame Melamine Lamination On Top And Mdf Sheet Bottom ,Polished. Top And Botton Lined With 8 Mm Thick Soft Pinning Washable Eva Sheet, Inside Glazed White. Raised Wall With Holes With Insecticide Inside Bottom To Make Box Airtight And Pestproof. Fitted With Brass Hinches,Index Card Holder And Clips , Entomological Pins : Black Enamel Coated 1 And 2 , Insect Pinning Block, Step Type, Hardwood With Holes At 25 Mm, 12 Mm And 7.5 Mm , Insect Collection Net ( Dismantling Type ) 2Ft Stainles Steel Handle, 1 Ft Radius Ring , Single Distillation Unit Glass 5 Litre/Hr Borosilicate Glass, Embedded Heater, Trapped Joint, Metallic Stand, Neon Indicator, Easy Setup, Safe Operation , Laborataory Weighing Balance 0.01G To 600Gm , Digital Colourimeter 10*8*5 Inch , Botany Department , Multi-Purpose Laboratory Centrifuge Multipurpose Laboratory Centrifuge With Microprocessor Based Memory And Digital Timer And Digital Rpm With Lcd Indicator Should Include:-Angel Rotor Heads 2 12X15 (Capacity In Ml) , Ph Meter (Range 0-14, With Prescision Of 0.1)- Combination Electrode, Bnc Connector, 1M Cable Length, With Electrode Holder And Power Adapter , Physics Department , Seelab3 Expeyes Trainer Kit , Optical Fiber Charecteristics Apparatus:To Fin Dthe Numerical Aperture, Attenuation And Bandwidth Of Optical Fibers: Laser Source, Powersupply, Adapter , And Function Generator, Two Fibers Of Dfferent Legth, Ldr Detector, Optical Voltmeter, Graduated Screen , Fiber Coupler Mounted On Translation Stage. , Fly Wheel - Radius Of Axle: 18 Mm, Mass Of Flywheel: 12 Kgs (Approx), Radius Of Flywheel: 125 Mm, Set Of Additional Mass To Change Flywheel Inertia, Set Of Hanging Mass, Four Wall Mounting Bolts, Rust Proof Well Painted Design , Torsion Pendulum - Steel Disk 20 Cm Diameter, With Pair Of Adjustable Chuck Nuts, Brass Wire Of 100Cm Length And 1.5 Mm Diameter, Steel Wire 100Cm Legnth And 1Mm Diameter, Pair Of Identical Mass, And Stand With Heavy Base And Length Of 90 Cms Height , Travelling Microscope - Three Axis Measurement Possibility: Horizontal, Vertical And Right Angled Transverse Motion, Coarse And Fine Movements, Resolution Of The Fine Movement: 10 Micron, Rack And Pinion Type Focusing Mechanism, 3X Long Working Distance Objective And A 10X Eyepiece With Cross Hair, Achromatic Type Objective, Base Construction : Cast Aluminium, Only High Quality Makes Need To Be Quoted , 0 - 30V / 3A Dual Power Supply With Automatic Overload Protection - Dual Dc Output Adjustible From 0 - 30 V With Coarse And Fine Controls - Current Limit Adjustable From 0 - 3A - Over Loading Indicated By Led - 3-Digit Led Display For Voltage And Current - Automatic Overload Current Protection - Excellent Line & Load Regulation - Low Ripple Voltage , Thermal Conductivity By Forbes Method Apparatus , Luxmeter For Measuring Intensity Of Light , Micrometer Screw Gauge (Stainless Steel) - Type: Analog, Measuring Range: 0-25Mm, Accuracy: 0.001Cm, Only High Quality Make Need To Be Quoted , Vernier Callipers - Stainless Steel, Measuring Range: 450 Mm, Accuracy: 100%, Display Type: Analog, Only High Quality Make Need To Be Quoted , 12V, 40 Annual Periodical Maintenance Hours Accumulator - 48 Months Warranty , 2 V , Accumulator , Malus Law Apparatus With Polariser, Analyser, Detector, Light Source And Optic Bench , Ic Trainer Kit - 2 No.S Of Bread Board, Fixed Dc Sources Of +5V, -5Vand +/-12V @0.5A, Variable Dc Sources O- +/-15V, @ 0.5A, 10No.S Of Logic Level Input Switches, 10No.S Of Logic Level Indicators, 2 No.S Of Decoders +Ve And -Ve Pulsers, Fixed Clock Frequency Of 1Hz, 10Hz, 10Khz,100Khz, One Seven Segment Display, A Unique Provision For Rest, Auto Power Off Protection When Supply Is Shorted, 1K Ohms, 10K Ohms, 100K Ohms,470K Ohms 1M Ohms Potentiometers Provided. , Permanent Bar Magnets 7.5Cm X 1.5 Cmx1cm , Jeagers Apparatus-For Measuring The Surface Tension Of A Liquid At Different Temperatures- Full Set , Magnetic Stirrer With Hotplate (Temperature Up To 250 Degree Celcius) , He-Ne Laser With Power Supply Giving Highly Directional Red Laser Beam , Hydrogen Discharge Tube Apparatus Full Set With Trasformer, Stand , Etc , Neodymium Magnets 12 Mm Diameter
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
18.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
19.
Defence #9578004 AOC
Tender For Repair Maintenance Of Vcbs Transformers Ht Cable And Connected Items At Af Stn Patiala Under Ge Af Ambala.; 1 Excavation in trenches, not exceeding 1.5mtr wide & not exceeding 1.5mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose type of soil complete all as specified & directed. 2 Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose type of soil complete all as specified & directed. 3 Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed. 4 M&L sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cmdeep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified & directed. 5 Supply & laying un-reinforced precast concrete cable cover , Class HVP type-1 with flat, size 300mm x 180mm x 40mm, laid flatfor protection of cable, adjacent to each other, perpendicular to central axis of cable complete all as specified & directed. 6 M&L double wall corrugated (DWC) HDPE pipe, outer dia 120mm, having corrugations on the outer surface and plain at inner surface, confirming to IS 14930(Part I & II) as in trenches/under road/under floor including cutting road/floor and making good wherever necessary or fixed to wall/pole with fixing arrangement for cable protection complete all as specified & directed. Note: Excavation & Earth work shall be measured & paid seperately. 7 M&L boring/augering of holes under road, pavement, taxi track, hardstanding for passing/crossing pipes/cables upto size 80mm dia/bore at suitable depth (not below than 600mm) byany means using necessary machinery / equipments complete without damaging the surface and removing excavated soil /material to a distance not exceeding 50mtr including supply & inserting GI pipe 80mm bore medium grade complete all as specified & directed.Note: One RM of boring & one RM of GI pipe shall be measured as one unit. 8 M&L plain cement concrete (PCC) 1:4:8, type D-2, using40mm graded mechanically crushed stone aggregates as in foundations, filling and mass concrete etc. complete all as specified & directed. 9 M&L plain cement concrete (PCC) 1:2:4, type B-1, using20mm graded mechanically crushed stone aggregates as in coping to pole etc. including necessary formwork to exposed surface finished even & smooth complete all as specified &directed. 10 Taking out / down faulty, unserviceable 11KV HT UG cable from trenches/duct/ HT poles, nominal cross sectional area from 95 sqmm to 120 Sqmm including disconnecting of cable and taking out PCC covers of any description complete allas specified & directed. Notes: (i) Excavation & Earth work shall be measured & paid separately.(ii) Serviceable cable covers/bricks will be kept aside for re-use and the unserviceable one shall be credited to contractor. 11 Supply, laying, jointing, testing & commissioning heavy duty, HT 11 KV ( E),XLPE insulated cable with aluminium conductor, screened with extruded semi conducting layer, insulation screening with copper tape cover laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked confirming to IS-7098 (Part-II), Size cross sectional area 95 Sqmm & 3 core laid as in trenches/pipes/ducts or fixed along poles/wall/equipment etc. complete all as specified & directed. 12 Description all as per BOQ item No.11.00 here-in-above but Size cross sectional area 120 Sqmm & 3 core. 13 S&F in repair Cable jointing kitfor 11 KV (Earthed) grade HT cable for indoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified & directed. 14 S&F in repair Cable jointing kitfor 11 KV (Earthed) grade HT cable for outdoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified & directed. 15 S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for indoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified & directed. 16 S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for outdoor termination heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified & directed. 17 S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for straight through heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm complete all as specified & directed. 18 S&F in repair Cable jointing kit for 11 KV (Earthed) grade HT cable for straight through heat shrink type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified & directed. 19 S&F cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed duly painted with two coats of aluminium paintover & including one coat of zinc oxide primer including dismantling of old unserviceable cross arms as existing complete all as specified & directed. 20 S&F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, Two-in-series assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified & directed. 21 Disconnecting electric connections of underground HT cable,11 KV, any size/type, from both sides and locating/detecting of pin point fault in cable with fault locating machine comprising impulse generator, acoustic fault locator & reflectometer (Laptop based) in the entire length with modern fault detector equipment by expert Engineers including reconnecting & commissioning the cable to make it functionalcomplete all as specified & directed.Notes: (i) The work will be executed after obtaining proper shutdown from main power house after liasoning with Engineer-in-charge.(ii) The fault location machine / equipments shall be arranged as early as possible by contractor but not later than 12 hours after intimation from AGE/JE concerned , failing which a penalty of Rs. 500/- every 12 hours for every job shall be leived.(iii) Excavation and Earthwork shall be measured & paid seperately. 22 S&F in repair cable route indicator made of mild steel plate of size 100mm x 150mm, 6mm thick welded with MS angle 40mm x 40mm x 4mm, one meter long, Cable HT embosed on MS plate, grouted inPCC 1:2:4 type B-1 using20 mm graded mechanically crushed stone aggregates block of size 300 mm x 300mm x 300mm as in foundation including necessary form work complete all as specified & directed.Notes: (i) Necessary earth work & PCC work including form work included in quoted rates.(ii) Steel surface shall be painted with two coat of synthetic enamel / aluminum paint over & including one coat of zinc oxide primer and quoted rated are deemed to be included for this aspect. 23 S&F in replacement 11KV Drop out fuse(set of three) single pole 200 Amp with insulators, barrel and suitable rating of fuse element as per site requirement complete all as specified & directed. 24 S&F in replacementlightening arrestor (set of three), expulsion type,11000 Volt, 65 kilo Amp discharge capacity with all fittingscomplete all as specified & directed.Note: The lighting arresters shall be of set of three 25 S&F in replacement switch Air break gang operated, triple pole, for horizontal or vertical operation, mechanically operated, outdoor type, mounted on 12 insulators and steel frame with operating mechanism & operating rod of 25mm bore, heavy grade GI pipe from ground level with & including locking arrangement & minumum 02 Nos. eye hook, 200 Amps current rating 11000 volts working pressure including making electrical connectionsto make it functional after testing complete all as specified & directed. 26 M&L in repair danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS clamps, bolts and nuts on pole, for HT(11/33 KV) of 25cm x 20cm size confirming to IS 2551 complete all as specified & directed. 27 M&L Servicing/checking/setting of Relay of 11KV SF6 breaker and calibration by primary injection and secondary injection including Service Cleaning of 11KV CB Limb, Cleaning & Lubrication of Mechanism, Cleaning & Crack observation of Porcelain Parts, Tightness Check of Electrical Control Wiring, checking of SF 6 Gas pressure(fill if required) including IR Testing, Coil Resistance Test, Operation Test Auto/Manual, Space heater and Indication Lamp Check complete all as specified & directed.Notes :- (i) Minor parts shall deemed to be included in quoted rates however major Spare parts shall be measured & paid seperately.(ii) The above job will be carried out at perodicity of six month (i.e first time within one month from the date of commencement of work and secondtime within seven months) (iii) Two times serviceing & calibration of each SF6 breaker shall be considered as One unit.(iv)Payment of this item will be made after successful completion of second time serviceing & calibration, however a partial payment after first time serviceing & calibration could be made at the discretion of GE. 28 S&F in replacement IDMTrelay with numerical relay for VCB tripping system (3 OC + 01 earth fault & high set instantaneous protection in single unit) suitable for operation on 24 volt to 110 volt DC all as per model No CGI14N of CG or equivalent in Seimens/Hager/Schneider complete all as specified & directed.Note :- Existing relay are IDMT type electromagnetic type hence any modification in the wiring & panel sheet enclosure requiredis deemed to be included in the quoted rates. 29 S&F in replacement Motor 230 Volts AC charged independent spring closing / tripping trip free operating mechanism with manual closing tripling push buttons and mechanical breaker “closed / open” spring charged / discharged indication complete all as specified & directed. 30 S&F in replacement Electrical releases coil, 24 volts DC complete all as specified & directed. 31 S&F in replacement Shunt trip coil, 24 volts DC complete all as specified & directed. . 32 S&F in replacement Auxiliary switch 32 Amp complete all as specified & directed. . 33 S&F in replacement 230 Volts AC single phase 80 watt rated strip type heater with toggle switch and thermostat complete all as specified & directed. 34 S&F in replacement 11KV metering CT, single core single ratio epoxy resin cast copper wound primary type with rate burden 5VA, class 0.5S confirming to IS-2705 complete all as specified & directed. 35 S&F in replacement epoxy resin cast CT dual core of ratio as per existing make and model 200/100/5-5A and of accuracy class 1.0, 5P, 10 burden 15VA for 11 KV as per relevant IS complete all as specified & directed. 36 S&F in replacement Potential transformer(set of three) ratio three single phase 11 KV/rt 3/110V/rt 3 class 0.5-3, with burden 50 VA and insulation level 28 / 75 conforming to IS – 3156 complete all as specified & directed. 37 S&F in replacement indication lamp (LED type) Red/Yellow/Blue/Green colour suitable for VCB etc. complete all as specified & directed. 38 S&F in replacement digital ammeter meter with shunt suitable for VCB 11000 volts , 400/630 Amp complete all as specified & directed . 39 S&F in replacement digital frequency meter with shunt suitable for VCB 11000 volts , 400/630/800 Amp complete all as specified & directed . 40 S&F in replacement TNC switch as per existing make & specifications suitable for VCB 400/630 Amps,11 KV including neccessary connection & testing complete all as specified & directed. 41 S&F in replacement closing coil assembly as per existing make & specifications suitable for VCB 400/630 Amps,11 KV including neccesarry connection & testing complete all as specified & directed 42 S&F in replacement Triping coil assembly as per existing make & specifications suitable for VCB 400/630 Amps,11 KV including neccesarry connection & testing complete all as specified & directed 43 S&F in replacementAmmmeter selector switch four step one off position as per existing make & specification suitable for VCB 400/630/800 Amps, 11 KV including necessary connection & testing complete all as specified & directed 44 S&F in replacement Voltmeter selector switch four step one off position as per existing make & specification suitable for VCB 400/630/800 Amps, 11 KV including necessary connection & testing complete all as specified & directed 45 S&F in replacement HV porcelain bushing of transformer(set of three) 12KV/250 Amp with metal partsbrass as per IS 3347 (Part III) and IS 2009 complete all as specified & directed. 46 Shifting of defective transformer upto 160 KVA from sub station to MES yard and installation of serviceable transformer from other location, placing on foundation / floor, connecting HV / LV and earthing strip complete all as specified & directed. Notes :- (i) Distance of shiting ranges between 1.00 Km to 1.50 Km.(ii) All petty parts including nut, bolts, lugs for cable and any other minor works and materialrequired for re-assembling are deemed to be included the rate quoted.(iii)The rate for transport and lifting of transformer by crane deemed to be included in the rate quoted. (iv) Oil testing oftransformers deemed to be included in the rate quoted. 47 Material and labour for checking of LT & HT side of transformer and replacement of burnt or heated lugs/nuts & bolts, checking oil level, checking silica gel, checking jumpers and GOD and tightening if found loose complete fully fucctional of transformer complete all as specified & directed. 48 De-hydration & filtration of transformer oil by using dehydration and filtration plant by means of Ultra High Vaccum double stage machine to remove impurities from oil such as moisture, dirt, air and other gases at site of installation in running condition of transformer including testing the oil before and after centrifuging from top and bottom of transformer to achieve the Break Down Voltage(BDV) value minimum 60KV at 2.5mm gap between electrode withstand for one minute including filling in transformer of any capacity complete all as specified & directed.Notes:-(i) Dehydration will be carried out at site in presence of MES rep and contractor will submit the dehydration report of each transformer. A record should be maintained by the contractor and should submit with RAR.(ii) Oil Test value record register shall be prepared in presence of AGE/JEand handed over the register to sub division on completion of work. 49 Supply & filling transformer oil of dielectric strength not less than 60KV to comply with IS-335 of 1993 complete all as specified & directed. 50 Preparation of external surfaces of existing transformer of capacity 63 KVA to 160 KVA for paintingincluding fins/radiators, removal of all existing paint/ rust/oil/grease and unwanted material and applying two coats of synthetic enamel metallic paint, smoke grey, by means of spray gun at site of installation of transformer including writing SM/MES number, capacity of transformer etc with black synthetic enamel paint complete all as specified & directed. 51 Supply & filling silicagel in granular form for transformers air breather of capacity 63 KVA to 160 KVA complete all as specified & directed. 52 S&F in repair transformer top cover gasket for capacity upto 160 KVA complete all as specified & directed. 53 Supply only electrical rubber hand gloves ( Kamfet class-2 , Electrical Insulated Hand gloves), Proof Voltage 20000 Volt, Working Voltage 17000 Volt, as Per IEC 60903-2014, Red Colour, Size 8,9,10,11 / Length 360mm complete all as specified & directed. 54 Supply only fibre glass discharge rod suitable for 11 KV working pressure including all accessories complete all as specified & directed. 55 Supply & laying in replacement high voltage insulating synthetic mat confirming to IS 15652:2006 with high die-electric strength upto 11 KV, fire retardant, insulation resistance upto 100000 mega ohms, with 5000 volt megger, good mechanical properties to withstand load and movement of breakers / trolleys and associated electrical equipment, no adverse effect of Acid, Alkalis and transformer oil of required size and thichness not less than 2.5mm complete all as specified & directed. 56 M&L25mm x 4mm galvanized iron(GI) strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing etc. complete all as specified & directed. 57 Dismantling and taking out /down existing unserviceable GI strip 25mm x 4mm as in earth continuity conductor or main earthing lead complete all as specified & directed. 58 M&L earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm, 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level, connected to GI earth lead strip 32mm x 6mm upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point& earth dolly & watering pipe GI 20 mm bore medium grade 1.5 mtr long including protection pipe GI light grade 40mm bore upto 7.5 mtr long, wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in any type of soil and refilling, pit chamber with PCC 1:3:6 type C-1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates pit cover slab 50 mm thick reinforced with 8 mm dia TMT bars @ 15cm c/c both ways including necessary form work all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion at site including dismantling/taking out/down of old existing earthing any type complete all as specified & directed. Notes:- On testing if the desired earth resistance(i.e. less than 5 ohm) is not obtained, earthing will be generated at No extra cost, till the desired earth resistance is obtained. 59 M&L preparation of surfaces and painting of steel tubular poles upto 1.5 mtr height from pedestal, with two coats ofsynthetic enamel paint in 30 cm wide strip (five strips), painting pattern shall be as per Airforce colour code including painting of pole coping with black paint and writing pole numbers with white paint on black circular base including marking of HT/LT withPainting ofpolecross arms bracket with two coats of aluminum paint over & including one coat of red oxideprimercomplete all as specified & directed. 60 Disconnecting HT/LT cables & Earthing connectionsof burnt /defective transformer of capacity 63 KVA to 160 KVA, 11KV/433 volts, 3 phase, any make,from 2/4pole structure / floor/platform mounted /CSS,taking down from site of installation carefuly & transporting the same to workshop for repair, opening, draining out transformer oil, dismantling complete & taking out core assembly & removing burntout windings, cleaning /washing of tank removing the dirt sludge and sticky materials from all parts of the transformerincluding core tank and cooling tubes, removal of damaged parts, dehydrating the core assembly, re-assembling after replacement of damaged parts of the transformer after repairs,making connections and filling dehydradated/fresh transformer oil and testing for all type of tests(routine test & full load test) including transportation back & reinstallation/connection of transformer at site complete all as specified & directed.Notes:- (i) Minor parts shall deemed to be included in quoted rates however major Spare parts shall be measured & paid seperately. All parts/components replaced shall be identical to those specified by original manufacturer. (ii) Taking out old/burnt winding of transformer included in quoted rates, however new winding shall be measured & paid separately. (iii) The draining of old transformer oil is deemed to included in quoted rates butfilling new transformer oil and dehydration & refilling of old transformer oil shall be measured & paid separately. 61 M&L winding of transformer any capacity at HT/LT side with super enamelled copper wire of gauge & weight as exists, varnishing & drying by vaccum impregnating, provindinginsulating material,fixing the coil in the position in core assembly and making connection as per original pattern complete all as specified & directed. 62 S&F in replacement PVC air breather of make & specifications as exist at site filled and with & including silica gel suitable for upto 100 KVA capacity transformer complete all as specified & directed. 63 Description all as per BOQ item No. 62.00 here-in-above but exceeding 100 KVA & upto 163 KVA capacity transformer. 64 S&F in replacement temperature gauge 0-100 degree celcius range round type complete all as specified & directed. 65 Repair and maintenance of existing transformer plinth suitable for installation of 120 to 160 KVA transformer, including complete electrical disconnection of existing transformer, relocation and lifting of transformer from plinth, including complete repair of plinth with proper civil works including brick work, PCC 1:2:4 type B2 using 20mm graded stone aggregate as in hard standing including painting to fencing work complete all as specified & directed.For Credit Schedule, refer tender documents. The amount of credit schedule shall be deducted from total quoted amount of BOQ to arrive contract sum.
Contract Date: Feb 13, 2026 Contract Value : 10.42 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Contract Date: Ref. Documents Contract Value : 42.56 Lakh
Boards / Undertakings / PSU No of Bidders 1
Jammu And Kashmir View Result →
22.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
23.
Agriculture #9499106 Technical Bid
Supply Of Electrical Material For Sugar Mill 2025-2026 Supply Of Electrical Material For Sugar Mill , Gpr Cum Synchronising Panel , Ammter[Digital Ac Ammter,96X96mm,Accuracy:0.5,Ctr:2500/1A,Aux. Supply 110Volt Dc,3 Phase,3Line Disply,Make= Elmeasure , Voltmeter[ Digital Ac Ammter,96X96mm,Accuracy:0.5,Range:0-15Kv Pt-Programable, Ptr:11Kv/110V Make:Elmeasure ,Make= Elmeasure , Ivt[110V/110V,50Va,Singal Phase,Cl:1.0,Ovf1.2 Continous Make:Pragati ,Make= Pragati , Coarse/Off/Fine Switch, 8 Pole,2Position With Off,32A ,Stay Put,Name Plate:Coarse/Off/Fine ,110V Dc,6 Contact In Fine, 2 Contact In Coarse, Pistol Grip Handle ,Make= Any Make , Reveres Reactive Power Relay Type-Xp2r,Ct I/P:1Amp,Pt I/P:110V Ac,Din Mounting, Aux Supply:110V Dc/2C/O Contacts Make:Woodward ,Make= Woodward , Roter Earth Fault Relay Type:Xr1, Aux.Volt:19-390V Dc,50Hz,Contacts2c/O,Mounting:Dinrail Make:Woodward ,Make= Woodward , Vector Surge Relay ,Make= Any Make , 11Kv ,3Core,300Sqmm,Xlpe,Steel Arrmoud Aluminium Cable ,Make= Any Make , 3Phase 110Kw 1440Rpm Frame Size 190 Voltage 415 Vac Motor ,Make= Any Make , Numerical Relay,Make= Any Make , Post Insulator For 132Kv Outdoor Type Switch Yard 90Kn ,Make= Any Make , Cummins Diesel Generator Sparte Parts ,Make= Any Make , Dc Voltage Dpm Rated I/P:500V Dc, Aux Supply:40-300V~45Va Model:Rish Eine+Voltage ,Make= Any Make , Avr Module ,Make= Abb , Hmi,Make= Abb , Dc Voltage Dpm Rated I/P:75Mv Dc, Aux Supply:40-300V~45Va Model:Rish Eine+Voltage ,Make= Any Make , 3Phase Voltage Dpm,I/P:100-500Vl-L,50-60Hz, Ptr:11Kv/110V ,Make= Any Make , Tripping & Closing Coil Assembly 110V Dc, For Abb Vcb Vd4 11Kv Ht Braker,Make= Abb , Breaker Poleabb Vcb, 11Kv Ht Braker ,Make= Abb , Auxalary Contact Assembly For Abb Vcb Vd4 H.T. Braker, Vd4 ,Make= Abb , Spring Charging Limit Switch 11 Kv, H.T. Breaker, Vd4 ,Make= Abb , Test Service Position Limit Switch 11Kv, Ht, Breaker Vd4 ,Make= Abb , Spring Charging Motor Assembly 240Vlt Ac For Abb Vcb Vd4 H.T. Breaker 11 Kv ,Make= Abb , Master Trip Relay[86],110V Dc Aux. Supply With 4No+3Nc Contacts,Flush Mounted Make:Abb ,Make= Abb , Current Transformer Epoxy Resin Cast . 3 Core -Ct -Core 1 -Cl0.5,10Ba,Core 2-Cl5p20,10Ba ,Core 3 Cl Ps Vk>=3Rct<5Oham Ct Ratio 25/1/1/1 For 11Kv 26.3 Ka For 3 Sec ,Make= Any Make , Potensial Transformer 11Kv/Rt3/11O/Rt3,30Va,Cl-0.5 ,Make= Any Make , Cane Unloader , Resistance For Lt Motor4.5 Kw ,Make= Any Make , Brake /Thruster-415 Volt 3 Ph ,Make= Any Make , Motor For Grab-415 Volt 3 Ph-15Hp ,Make= Any Make , Motor For Lt Slipring 415Volt 3 Ph- 4.5 Kw ,Make= Any Make , Rectifier Bridge-24V Dc-Mic ,Make= Any Make , Motor For Lt Main Hydraulic 415Volt 3 Ph-40Hp ,Make= Any Make , 132Kv Switchyard , Vector Surge Relay, Mrg2-1Hrd,Make:C&S ,Make= C&S , Sf6 Breaker Pole, 132 Kv ,Make= Abb , Post Insulator For 132Kv Line,90Kn ,Make= Abb , Lighting Arrestor For 132Kv Grid ,Make= Abb , Out Door Ct For V132kv Line Ctr 200/1Amp ,Make= Abb , Out Door Pt For 132Kv Line Ptr 132Kv/Rt3/110V/Rt3 ,Make= Abb , Chemical Earthing Electrode 10 Feet Length ,Make= Any Make , Carbon Brush , Techo Generator ( As Per Sample ) ,Make= Any Make , Laveler & Chopper-40X20x40/ 15Me ,Make= Any Make , Fibrizor-40X20x40/ C80x ,Make= Any Make , Lighting Materials , Asr Panels, Fan-Dia 380 Mm,3Ph,0.18Kw ,1400 Rpm-Marathon ,Make= Marathon , Vfd Panel Cooling Fan , Auxalary Fan,Make= Abb , Cooling Fan For Panel ,Make= Abb , A Batch M/C Power Module Cooling Fan,Make= Abb , Mill Vfd Module Cooling Fan Set ( Double ) ,Make= Abb , Techo Genrator For Dc Batch M/C Motor ,Make= Any Make , Mcb & Fuses , Selectror Switch, Type Spp29b,25Amps ,Make= Any Make , Selectror Switch,Type; 1S260, 10Amps ,Make= Any Make , Contactor Relay And Other Electric Material , Electronic Timercat Id:12Sdt0 Supply 240V Timing: 3Sec-120 Sec, Star-Delta ,Make= Any Make , Contactor Model: 3Ts35 00-0A..8K,Ac-3,40Amp, Coil Voltage -110Vac ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 25 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 35 Mm Square ,Make= Any Make , New Electrical Item , Led Tube Light Fitting 20 Watt , Led Light Complete Fitting 50 Watt , Led Flood Light Complete Fitting 200 Watt , S.P Switch 6 Amp, Anchor , 3/5 Pin Sockat 6 Amp, Anchor , S.P Switch 16 Amp, Anchor , 3/5 Pin Sockat 16 Amp, Anchor , 3 Pin Plug Top 16 Amp, Anchor , 3 Pin Plug Top 6 Amp, Anchor , Led Bulb 7 Watt 220 Vac , Led Bulb 9 Watt 220 Vac , Led Bulb 15 Watt 220 Vac , Led Bulb 20 Watt 220 Vac , P.T Bulb 320 Volt Ac , Electric Bell, 220 Vac , Celling Fan 48, 220 Volt Ac , Exhaust Fan, 24, 220 Volt Ac , Heat /Shrink 300 Mm2 X 3 Core Indoor Type, Make- Rechem , Exhaust Fan, 18, 220 Volt Ac , Single Phase 1.5 H.P Motor With Blower 220 V Ac , Impact Type Eclectormagnetic Vibrator With Controller, 220 Volt Ac Make- Vaideni , Electric Motor 3 Phase Induction Motor, Frame Size-90L, Power-2.2 Kw, Rpm-2876 Foot Mounted Type, Make-Siemens , Vfd Drive Cooling Fan, Ebmpapst Make, 6318/2, Tdhhp-127 Watt, 48/Dc, 2.65 Amp , Current Collector For Cane Unloader Bus Bar. , P.T. Holder, Anchor , Smps, 220 Vac/Vdc, 10 Amp, , Screw Druver Set Multiper Type, Th08, Thaparia , Coarge/ Off/Fine Seleator Switch - 32 Amp Spc 32 K 484/J 7 32A/660V Ac/Dc , (Switron)- Spd 125B/Ta3, 16A/250V, Dc Live/Dead Selector Switch -16A , Auto/Manual Seclection Switch (Switron)-113B/Ta3, -16A/250V , Selecter Switch (Switron)-Sbc 32P-244 R4 32A/660V Ac/Dc , Straight Bolt Heater Part No- Bt 0950143, Size-15.7X285 Mm, 220 Vac, Power 1.8 Kw , Neutral , Tnc Switch Trip/Close Ac-23 A-Kw, 3Ph-5.5 Ac-15 , (Fuse) 160 Fee Eaton-160A, British Standard Fuse 500V Dc , Screw Drivar 4 Mech- T-10, T-15, T-20, T-25 (Torx) , (Ups)- Online Ups 1 Kva, 24 Vdc, 4.3 A.Ac 1 Capacity, 1 Kva/800 Watt Bus Rating- 24 Vdc, 45A , Motor Connection Plate Motor -110 Kw, 2862 Rpm, Current180a, Kirloskar, Electric Hubbali Mic No-Tef-102-05 , Limit Switch (At No- Nlia-22 Shat Blower) , Coutral Card Acs 580 Vfd 01-246A-4 , Elbow (M.S.) Size 20 Mm , M.S Cousrefar Size 20 Mm , White Tools Make Miranda Workshop, Size 15X15 Mm, 20X20 Mm , Ss Measuring Scale - 1 Meter , Aluminium Lug Ring Type, 35 Sq Mm, 25 Sq Mm , Copper Flexicible Cable Single Core Lead - 90 Sq Mm, , Copper Flexicible Cable Single Core Lead - 70 Sq Mm, , Copper Flexicible Cable Single Core Lead - 50 Sq Mm, , Copper Flexicible Cable Single Core Lead - 35 Sq Mm, , Copper Flexicible Cable Single Core Lead - 25 Sq Mm, , Copper Flexicible Cable Single Core Lead - 16 Sq Mm, , Copper Flexicible Cable Single Core Lead - 10 Sq Mm, , Coorse/ Off/Fine Selector Switch, 8 Pole,2 Position With Off 32 Amp, Stay Put, 110 V Dc,6 Contacts In Fien And 2 Contact In Coorse With Pistal Grip Handle Make :-Switron , Digital Pf Meter 3 Ph , M Wire 96X96mmctr 2500/1A, 11Kvv3/110Vv3 0.5 Log 05 Lead, Cl :05, Aux Supply 110 Vdc Make- Elmeasure , Digital A.C Voltmeter 96X96 Mm Accuracy-05, Rang 0-15 Kv, Pt Pragmmable Ptr 11 Kv/110V Ac Built In Selector Switch, Aux Supply , Ammeter, Digital Ac Commter 96X96 Mm Accuracy - 0.5 Ctr 2500/ Amp, Ring 2-2500 Amp Aux Supply 110 Vdc 3 Phase 3 Line Disply Make Elmasure , Aux Contactor , Amek Siemeni 110 Vdc, 4 No Base 2 No +2Nc Add-On-Block
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
24.
Agriculture #9491817 Technical Bid
Supply Of Electrical Material For Sugar Mill 2025-2026 Supply Of Electrical Material For Sugar Mill , Gpr Cum Synchronising Panel , Ammter[Digital Ac Ammter,96X96mm,Accuracy:0.5,Ctr:2500/1A,Aux. Supply 110Volt Dc,3 Phase,3Line Disply,Make= Elmeasure , Voltmeter[ Digital Ac Ammter,96X96mm,Accuracy:0.5,Range:0-15Kv Pt-Programable, Ptr:11Kv/110V Make:Elmeasure ,Make= Elmeasure , Ivt[110V/110V,50Va,Singal Phase,Cl:1.0,Ovf1.2 Continous Make:Pragati ,Make= Pragati , Coarse/Off/Fine Switch, 8 Pole,2Position With Off,32A ,Stay Put,Name Plate:Coarse/Off/Fine ,110V Dc,6 Contact In Fine, 2 Contact In Coarse, Pistol Grip Handle ,Make= Any Make , Reveres Reactive Power Relay Type-Xp2r,Ct I/P:1Amp,Pt I/P:110V Ac,Din Mounting, Aux Supply:110V Dc/2C/O Contacts Make:Woodward ,Make= Woodward , Roter Earth Fault Relay Type:Xr1, Aux.Volt:19-390V Dc,50Hz,Contacts2c/O,Mounting:Dinrail Make:Woodward ,Make= Woodward , Vector Surge Relay ,Make= Any Make , 11Kv ,3Core,300Sqmm,Xlpe,Steel Arrmoud Aluminium Cable ,Make= Any Make , 3Phase 110Kw 1440Rpm Frame Size 190 Voltage 415 Vac Motor ,Make= Any Make , Numerical Relay,Make= Any Make , Post Insulator For 132Kv Outdoor Type Switch Yard 90Kn ,Make= Any Make , Cummins Diesel Generator Sparte Parts ,Make= Any Make , Dc Voltage Dpm Rated I/P:500V Dc, Aux Supply:40-300V~45Va Model:Rish Eine+Voltage ,Make= Any Make , Avr Module ,Make= Abb , Hmi,Make= Abb , Dc Voltage Dpm Rated I/P:75Mv Dc, Aux Supply:40-300V~45Va Model:Rish Eine+Voltage ,Make= Any Make , 3Phase Voltage Dpm,I/P:100-500Vl-L,50-60Hz, Ptr:11Kv/110V ,Make= Any Make , Tripping & Closing Coil Assembly 110V Dc, For Abb Vcb Vd4 11Kv Ht Braker,Make= Abb , Breaker Poleabb Vcb, 11Kv Ht Braker ,Make= Abb , Auxalary Contact Assembly For Abb Vcb Vd4 H.T. Braker, Vd4 ,Make= Abb , Spring Charging Limit Switch 11 Kv, H.T. Breaker, Vd4 ,Make= Abb , Test Service Position Limit Switch 11Kv, Ht, Breaker Vd4 ,Make= Abb , Spring Charging Motor Assembly 240Vlt Ac For Abb Vcb Vd4 H.T. Breaker 11 Kv ,Make= Abb , Master Trip Relay[86],110V Dc Aux. Supply With 4No+3Nc Contacts,Flush Mounted Make:Abb ,Make= Abb , Current Transformer Epoxy Resin Cast . 3 Core -Ct -Core 1 -Cl0.5,10Ba,Core 2-Cl5p20,10Ba ,Core 3 Cl Ps Vk>=3Rct<5Oham Ct Ratio 25/1/1/1 For 11Kv 26.3 Ka For 3 Sec ,Make= Any Make , Potensial Transformer 11Kv/Rt3/11O/Rt3,30Va,Cl-0.5 ,Make= Any Make , Cane Unloader , Resistance For Lt Motor4.5 Kw ,Make= Any Make , Brake /Thruster-415 Volt 3 Ph ,Make= Any Make , Motor For Grab-415 Volt 3 Ph-15Hp ,Make= Any Make , Motor For Lt Slipring 415Volt 3 Ph- 4.5 Kw ,Make= Any Make , Rectifier Bridge-24V Dc-Mic ,Make= Any Make , Motor For Lt Main Hydraulic 415Volt 3 Ph-40Hp ,Make= Any Make , Fuse , Semi Conductor Fuse 1400 Amp(Mill Vfd) ,Make= Bussmann , Semi Conductor Fuse 900 Amp (Batch M/C ) ,Make= Bussmann , Semi Conductor Fuse 315 Amp (Main Cane Carr.) ,Make= Bussmann , Semi Conductor Fuse 315 Amp (Juice Sulphitor) ,Make= Bussmann , Semi Conductor Fuse 315 Amp (Pan Circulator) ,Make= Bussmann , Semi Conductor Fuse 20 Amp ( B=C Grain ) ,Make= Bussmann , 132Kv Switchyard , Vector Surge Relay, Mrg2-1Hrd,Make:C&S ,Make= C&S , Sf6 Breaker Pole, 132 Kv ,Make= Abb , Post Insulator For 132Kv Line,90Kn ,Make= Abb , Lighting Arrestor For 132Kv Grid ,Make= Abb , Out Door Ct For V132kv Line Ctr 200/1Amp ,Make= Abb , Out Door Pt For 132Kv Line Ptr 132Kv/Rt3/110V/Rt3 ,Make= Abb , Copper Earthing Strip Size:-50Mmx5mm,Make= Any Make , Chemical Earthing Electrode 10 Feet Length ,Make= Any Make , Carbon Brush , Techo Generator ( As Per Sample ) ,Make= Any Make , Laveler & Chopper-40X20x40/ 15Me ,Make= Any Make , Fibrizor-40X20x40/ C80x ,Make= Any Make , Lighting Materials , Elcctronic Ignitor (70W/150W/400W)-Bajaj ,Make= Bajaj , Hpsv Lamp 400Watt-Bajaj ,Make= Bajaj , Hpsv Bellast 400 Watt(Type-Bjhbi/Mbi)-Bajaj ,Make= Bajaj , Hpsv Bellast 400 Watt-Bajaj ,Make= Bajaj , Hpsv Bellast 250 Watt-Bajaj ,Make= Bajaj , Hpsv Lamp 250 Watt-Bajaj ,Make= Bajaj , Hpsv Bellast 250 Watt-Bajaj ,Make= Bajaj , Capacitor3.15 Mfd-Bajaj ,Make= Bajaj , Capacitor2.5 Mfd-Bajaj ,Make= Bajaj , Fluorescent Tube Light 36 Watt-Bajaj ,Make= Bajaj , Hpmv Lamp 250 Watt ,Make= Bajaj , Helozen Lamp 500 Watt ,Make= Bajaj , Helozen Lamp 1000 Watt ,Make= Bajaj , Helozen Lamp Fitting 500 Watt ,Make= Bajaj , Helozen Lamp Fitting 1000 Watt ,Make= Bajaj , Asr Panels, Fan-Dia 380 Mm,3Ph,0.18Kw ,1400 Rpm-Marathon ,Make= Marathon , Vfd Panel Cooling Fan , Auxalary Fan,Make= Abb , Cooling Fan For Panel ,Make= Abb , A Batch M/C Power Module Cooling Fan,Make= Abb , Mill Vfd Module Cooling Fan Set ( Double ) ,Make= Abb , Techo Genrator For Dc Batch M/C Motor ,Make= Any Make , Power Plant Electrical Requirment , Emergency Push Button Mushroom Head(1No+1Nc) ,Make= Any Make , Hand Lamp Set 230V ,Make= Any Make , Cable Flexible 2 Core* 1.5 Mmsq Copper ,Make= Any Make , Mcb & Fuses , Hrc Fuse 200 A, Semiconductor,Make= Bussmann , Hrc Fuse 315 A, Semiconductordin-1 ,Make= Bussmann , Hrc Fuse 630A, Semiconductor Size Din -2 ,Make= Bussmann , Hrc Fuse 160 A, Semiconductorsize Din-000 ,Make= Bussmann , Hrc Fuse , Semiconductor 1000 Adin-3 ,Make= Bussmann , Hrc Fuse 63, Semiconductor, Din-000 ,Make= Bussmann , Selectror Switch, Type Spp29b,25Amps ,Make= Any Make , Selectror Switch,Type; 1S260, 10Amps ,Make= Any Make , Potentio Meter 3 Pin ,Make= Any Make , Contactor Relay And Other Electric Material , Electronic Timercat Id:12Sdt0 Supply 240V Timing: 3Sec-120 Sec, Star-Delta ,Make= Any Make , Contactor Model: 3Ts35 00-0A..8K,Ac-3,40Amp, Coil Voltage -110Vac ,Make= Any Make , Push Button – No Element, Teknic Code:Sf ,Make= Teknic , Push Button – Nc Element, Teknic Code:S2 ,Make= Teknic , Mushroom Actuator (Plastic), Teknic Code P2amlkb4 ,Make= Teknic , Flush Switch Actuator Teknic Code: P2af3 ,Make= Teknic , 2W/2W(102)(Pdc) Enclosure, Colour :Ral 7032/Black, Teknic Code:2006C13 ,Make= Teknic , Ammeter Selector Switch, 61325 ,Make= Salzer , Voltmeter Selector Switch 6A, 61312 ,Make= Salzer , Voltmeter 0-500V, 96X96mm, Mtr500d1d096and ,Make= Ae , Ammeter Ct Operated 96X96mm ,Make= Ae , Indicator Red – Eilr240a, 230V ,Make= Esbee , Indicator Yellow – E1ly240a, 230V ,Make= Esbee , Indicator Blue – Eilb240a, 230V ,Make= Esbee , Indicator Amber – Eila240a, 230V ,Make= Esbee , Indicator Green – Eilg240a, 230V ,Make= Esbee , Copper Lugs Pin Type Size 1.5 Mm Square ,Make= Dowells , Copper Lugs Pin Type Size 2.5 Mm Square ,Make= Dowells , Copper Lugs Pin Type Size 4 Mm Square ,Make= Dowells , Copper Lugs Pin Type Size 6 Mm Square ,Make= Dowells , Copper Lugs Pin Type Size 10 Mm Square ,Make= Dowells , Copper Lugs U Type Size 2.5 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 1.5 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 2.5 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 4.6 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 10 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 16 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 25 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 35 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 50 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 70 Mm Square ,Make= Dowells , Copper Lugs Ring Type Size 45 Mm Square ,Make= Dowells , Ammeter Ct, Operated-250/5 A Size – 96Mmx96mm ,Make= Any Make , Ct Shorting Terminals Size-6 Mm Square, Catdm4 ,Make= Elemex , Ct Shorting Terminals Size-6 Mm Square, Kutsd6 ,Make= Elemex , Din Channel ‘G’ Type In Meter ,Make= Any Make , Din Channel ‘C’ Type In Meter ,Make= Any Make , Single Pole Mcb C-8 Amp ,Make= Any Make , Single Pole Mcb C-10 Amp ,Make= Any Make , Single Pole Mcb C-16 Amp ,Make= Any Make , Double Pole Mcb C-4 Amp ,Make= Any Make , Double Pole Mcb C-6 Amp ,Make= Any Make , Double Pole Mcb C-10 Amp ,Make= Any Make , Double Pole Mcb C-16 Amp ,Make= Any Make , Three Pole Mcb C-32 Amp, ,Make= Any Make , Three Pole Mcb C-40 Amp ,Make= Any Make , Three Pole Mcb C-63 Amp ,Make= Any Make , Four Pole Mcb C-63 Amp ,Make= Any Make , Four Pole Elcb C-63 Amp, Leakage Current 100 M ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 10 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 16 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 25 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 35 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 50 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 70 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 95 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 120 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 150 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 185 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 240 Mm Square ,Make= Any Make , Aluminium Lugs Of Ring Type Size – 300 Mm Square ,Make= Any Make , Becktol Red Varnish In Ltr. ,Make= Dr. Beek , Insulating Varnish In Ltr. ,Make= Dr. Beek , Cotton Tap 1” X 30 Meter In Rolls ,Make= Any Make , Empire Tap 1” X 30 Meter In Rolls ,Make= Any Make , Ht Tap In Rolls ,Make= Any Make , Water Proof Self Fusing Silicon Rubber Tao Electrical In Rolls ,Make= Any Make , Pvc Tap (Red, Yellow, Blue & Black) ¾” X 6.6 Meter ,Make= Any Make , Pin Type Lamp Holder ,Make= Any Make , 3 Position Sensor Switch, Hg-121C, 16 Amps. ,Make= Any Make , Isolated Converters, 9000U Series ,Make= Masibus , Isolated Converters, S1sd-1Ai-2U ,Make= Pepperl Plus Fuchs , Isolated Converters, S1sd-1Ai-1U ,Make= Pepperl Plus Fuchs , Proximity Sensor For Batch M/C(Sw-4051-P0d1-B30(Pnp- N0), 10-30V Dc, Sn Dist: 15Mm, Load: 400Ma ,Make= Any Make , Carbon Brush Holder For 200 Kw Crompton Make Motor For Carbon Brush 40X40x20 ,Make= Any Make , Carbon Brush For Air Blower In Set ,Make= Bosch , Soldering Iron 60 Watt (Round And Pointed Flat- Tip) ,Make= Any Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
25.
Agriculture #9488496 Technical Bid
Tender For Supply Of Electrical Material For Sugar Mill - GPR CUM SYNCHRONISING PANEL 2 AMMTER[DIGITAL AC AMMTER,96X96mm,ACCURACY:0.5,CTR:2500/1A,AUX. SUPPLY 110VOLT DC,3 PHASE,3LINE DISPLY 3 VOLTMETER[ DIGITAL AC AMMTER,96X96mm,ACCURACY:0.5,Range:0-15kv PT-Programable, PTR:11KV/110V MAKE:ELMEASURE 4 MFM[DIGITALMFM METER,96X96mm,CTR 2500/1A, PTR 11KV/110V, AUX SUPPLY 110VOLT DC 5 FREQUENCY METER[DIGITAL FREQUENCY METER 96X96mm,Input110volt AC,AUX SUPPLY110VOLT DC,CL:0.2,RANGE 45-50HZ 6 MW Tranducer[3phase,4wire,3element,MW tranducer,aux. supply 110volt DC, CTR2500/1A,MAKE: 7 IVT[110V/110V,50VA,SINGAL PHASE,CL:1.0,OVF1.2 Continous make:pragati 8 Breker control switch[spring return to neutral 2trip,2close,32amp,110V DC, Contact with pistal grip handle] make:SWITRON 9 SEMAPHORE[110V DC,48mm Dia make:DAV{deepl} 10 AUTO/MANUAL SEL SWITCH[1Pole,2way with off,16A,Stay put ,name plate:AUTO-OFF-MANUAL,110 DC,KNOB TYPE MAKE:SWITRON 11 LIVE/DAD[1Pole,2way with off,16A,Stay put ,name plate:LIVE-OFF-DAD,110 DC,KNOB TYPE MAKE:SWITRON 12 Coarse/OFF/FINE SWITCH, 8 pole,2position with OFF,32A ,STAY PUT,NAME PLATE:COARSE/OFF/FINE ,110V DC,6 CONTACT IN FINE, 2 CONTACT IN COARSE, PISTOL GRIP HANDLE 13 BREAKER SELECTOR SWITCH,1 POLE,6WAY WITH OFF,32AMP,STAY PUT,110V DC,KNOB TYPE[ MAKE:SWITRON] 14 AUX. CONTACTORS[110V DC,2NO+2NC BASE WITH ADD ON BLOCK 2NO+2NC MAKE:SIEMENS TYPE:3RH2911 1HAO2 15 ILLUMINATION LAMP [INDICATION LAMP RED, GREEN,YELLOW,BLUE]DIA22.5mm, 110volt DC,LED TYPE MAKE:TEKNIC 16 REVERES REACTIVE POWER RELAY TYPE-XP2R,CT I/P:1AMP,PT I/P:110V AC,DIN MOUNTING, AUX SUPPLY:110V DC/2C/O CONTACTS MAKE:WOODWARD 17 ROTER EARTH FAULT RELAY TYPE:XR1, AUX.VOLT:19-390V DC,50HZ,CONTACTS2C/O,MOUNTING:DINRAIL MAKE:WOODWARD 18 vector surge relay 19 11KV ,3CORE,300Sqmm,XLPE,STEEL ARRMOUD ALUMINIUM CABLE 20 3PHASE 110KW 1440RPM FRAME SIZE 190 VOLTAGE 415 VAC MOTOR 21 NUMERICAL RELAY 22 POST INSULATOR FOR 132KV OUTDOOR TYPE SWITCH YARD 90KN 23 CUMMINS DIESEL GENERATOR SPARTE PARTS 24 DC VOLTAGE DPM RATED I/P:500V DC, AUX SUPPLY:40-300V~45VA MODEL:RISH Eine+voltage 25 AVR MODULE 26 HMI 27 DC VOLTAGE DPM RATED I/P:75mV DC, AUX SUPPLY:40-300V~45VA MODEL:RISH Eine+voltage 28 3PHASE VOLTAGE DPM,I/P:100-500VL-L,50-60HZ, PTR:11KV/110V 29 TRIPPING & CLOSING COIL ASSEMBLY 110V DC, FOR ABB VCB VD4 11kv HT BRAKER 30 BREAKER POLEABB VCB, 11KV HT BRAKER 31 AUXALARY CONTACT ASSEMBLY FOR ABB VCB VD4 H.T. BRAKER, VD4 32 SPRING CHARGING LIMIT SWITCH 11 KV, H.T. BREAKER, VD4 33 TEST SERVICE POSITION LIMIT SWITCH 11KV, HT, BREAKER VD4 34 SPRING CHARGING MOTOR ASSEMBLY 240VLT AC FOR ABB VCB VD4 H.T. BREAKER 11 KV 35 INDICATION LAMP RED ,GREEN,BLUE,AMBER,WHITE,LED TYPE,110V DC,22.5mm DIA MAKE:ESBEE 36 TNC SWITCH 25A,2NO+2NC SPRING RETURN MAKE :SALZER 37 MASTER TRIP RELAY[86],110V DC AUX. SUPPLY WITH 4NO+3NC CONTACTS,FLUSH MOUNTED MAKE:ABB 38 CURRENT TRANSFORMER EPOXY RESIN CAST . 3 CORE -CT -CORE 1 -CL0.5,10BA,CORE 2-CL5P20,10BA ,CORE 3 CL PS VK>=3RCT<5OHAM CT RATIO 25/1/1/1 FOR 11KV 26.3 KA FOR 3 SEC 39 POTENSIAL TRANSFORMER 11KV/RT3/11O/RT3,30VA,CL-0.5 40 SELECTOR SWICH,6AMP,1POLE,2WAY WITHOUT OFF MAKE SALZER 41 132KV SWITCHYARD 42 VECTOR SURGE RELAY, MRG2-1HRD,MAKE:C&S 43 SF6 BREAKER POLE, 132 KV 44 POST INSULATOR FOR 132KV LINE,90KN 45 LIGHTING ARRESTOR FOR 132KV GRID 46 OUT DOOR CT FOR V132KV LINE CTR 200/1AMP 47 OUT DOOR PT FOR 132KV LINE PTR 132KV/RT3/110V/RT3 48 copper earthing strip size:-50mmx5mm 49 chemical earthing electrode 10 feet length 50 Cane Unloader 51 Resistance for LT Motor4.5 KW 52 Brake /Thruster-415 volt 3 ph 53 Motor for Grab-415 volt 3 ph-15HP 54 Motor for LT Slipring 415Volt 3 ph- 4.5 KW 55 Rectifier Bridge-24V DC-MIC 56 Motor for LT Main hydraulic 415Volt 3 ph-40HP 57 MCCMILL HOUSE 58 Control transformer 415V/230V 3.0KVA (2.5% & 5% TAP ON PRIMERY SIDE) AE/KAPP/KALPA 59 CARBON BRUSH 60 Techo Generator ( As Per Sample ) 61 Cane Unloader 25x15x8 mm 62 LAVELER & CHOPPER-40x20x40/ 15ME 63 FIBRIZOR-40x20x40/ C80X 64 LIGHTING MATERIALS 65 Elcctronic Ignitor (70W/150W/400W)-Bajaj 66 HPSV LAMP 400WATT-Bajaj 67 HPSV BELLAST 400 WATT(TYPE-BJHBI/MBI)-Bajaj 68 HPSV BELLAST 400 WATT-Bajaj 69 HPSV BELLAST 250 WATT-Bajaj 70 HPSV LAMP 250 WATT-Bajaj 71 HPSV BELLAST 250 WATT-Bajaj 72 Capacitor3.15 MFD-Bajaj 73 Capacitor2.5 MFD-Bajaj 74 Fluorescent Tube Light 36 Watt-Bajaj 75 HPMV LAMP 250 WATT 76 HELOZEN LAMP 500 WATT 77 HELOZEN LAMP 1000 WATT 78 HELOZEN LAMP FITTING 500 WATT 79 HELOZEN LAMP FITTING 1000 WATT 80 ASR PANELS, FAN-Dia 380 mm,3ph,0.18KW ,1400 RPM-MARATHON 81 VFD PANEL COOLING FAN 82 AUXALARY FAN 83 COOLING FAN FOR PANEL 84 A BATCH M/C POWER MODULE COOLING FAN 85 MILL VFD MODULE COOLING FAN SET ( DOUBLE ) 86 TECHO GENRATOR FOR DC BATCH M/C MOTOR 87 MCC AND LIGHTING DB 88 MCB 1 POLE 2 AMP 89 MCB 1 POLE 4 AMP 90 MCB 2 POLE 20 AMP 91 MCCB 125 AMP3 POLE 92 MCCB 160 AMP3 POLE 93 FUSE 94 SEMI CONDUCTOR FUSE 1400 AMP(MILL VFD) 95 SEMI CONDUCTOR FUSE 900 AMP (BATCH M/C ) 96 SEMI CONDUCTOR FUSE 315 AMP (MAIN CANE CARR.) 97 SEMI CONDUCTOR FUSE 315 AMP (JUICE SULPHITOR) 98 SEMI CONDUCTOR FUSE 315 AMP (PAN CIRCULATOR) 99 SEMI CONDUCTOR FUSE 20 AMP ( B=C GRAIN ) 100 POWER PLANT ELECTRICAL REQUIRMENT 101 Emergency Push Button mushroom head(1NO+1NC) 102 Hand Lamp set 230v 103 Cable Flexible 2 core* 1.5 mmsq Copper 104 MCB & FUSES 105 HRC Fuse 200 A, SemiConductor 106 HRC Fuse 315 A, SemiConductorDIN-1 107 HRC Fuse 630A, SemiConductor size DIN -2 108 HRC Fuse 160 A, SemiConductorsize DIN-000 109 HRC Fuse , SemiConductor 1000 ADIN-3 110 HRC Fuse 63, semiconductor, DIN-000 111 selectror switch, Type SPP29B,25Amps 112 selectror switch,Type; 1S260, 10Amps 113 Potentio Meter 3 pin 114 CONTACTOR RELAY AND OTHER ELECTRIC MATERIAL 115 Electronic TimerCat ID:12SDT0 supply 240V timing: 3sec-120 sec, star-Delta 116 Contactor Model: 3TS35 00-0A..8K,AC-3,40Amp, coil voltage -110VAC 117 Push Button – No Element, TEKNIC Code:Sf 118 Push Button – NC Element, TEKNIC Code:S2 119 Mushroom Actuator (Plastic), TEKNIC Code P2AMLKB4 120 Flush Switch Actuator TEKNIC Code: P2AF3 121 2W/2W(102)(PDC) Enclosure, Colour :RAL 7032/Black, TEKNIC Code:2006C13 122 Ammeter Selector Switch, 61325 123 Voltmeter Selector Switch 6A, 61312 124 Voltmeter 0-500V, 96X96mm, MTR500D1D096AND 125 AMMETER CT OPERATED 96X96mm 126 Indicator Red – EILR240A, 230V 127 Indicator Yellow – E1LY240A, 230V 128 Indicator Blue – EILB240A, 230V 129 Indicator Amber – EILA240A, 230V 130 Indicator Green – EILG240A, 230V 131 Copper Lugs Pin Type Size 1.5 mm Square 132 Copper Lugs Pin Type Size 2.5 mm Square 133 Copper Lugs Pin Type Size 4 mm Square 134 Copper Lugs Pin Type Size 6 mm Square 135 Copper Lugs Pin Type Size 10 mm Square 136 COPPER LUGS U TYPE SIZE 2.5 mm Square 137 Copper Lugs Ring Type Size 1.5 mm Square 138 Copper Lugs Ring Type Size 2.5 mm Square 139 Copper Lugs Ring Type Size 4.6 mm Square 140 Copper Lugs Ring Type Size 10 mm Square 141 Copper Lugs Ring Type Size 16 mm Square 142 Copper Lugs Ring Type Size 25 mm Square 143 Copper Lugs Ring Type Size 35 mm Square 144 Copper Lugs Ring Type Size 50 mm Square 145 Copper Lugs Ring Type Size 70 mm Square 146 Copper Lugs Ring Type Size 45 mm Square 147 Ammeter CT, Operated-250/5 A Size – 96mmx96mm 148 CT Shorting Terminals Size-6 mm Square, CATDM4 149 CT Shorting Terminals Size-6 mm Square, KUTSD6 150 DIN Channel ‘G’ Type in Meter 151 DIN Channel ‘C’ Type in Meter 152 Single Pole MCB C-8 AMP 153 Single Pole MCB C-10 AMP 154 Single Pole MCB C-16 AMP 155 Double Pole MCB C-4 AMP 156 Double Pole MCB C-6 AMP 157 Double Pole MCB C-10 AMP 158 Double Pole MCB C-16 AMP 159 Three Pole MCB C-32 AMP, 160 Three Pole MCB C-40 AMP 161 Three Pole MCB C-63 AMP 162 Four Pole MCB C-63 AMP 163 Four Pole ELCB C-63 AMP, Leakage Current 100 M 164 Aluminium Lugs of Ring Type Size – 10 mm Square 165 Aluminium Lugs of Ring Type Size – 16 mm Square 166 Aluminium Lugs of Ring Type Size – 25 mm Square 167 Aluminium Lugs of Ring Type Size – 35 mm Square 168 Aluminium Lugs of Ring Type Size – 50 mm Square 169 Aluminium Lugs of Ring Type Size – 70 mm Square 170 Aluminium Lugs of Ring Type Size – 95 mm Square 171 Aluminium Lugs of Ring Type Size – 120 mm Square 172 Aluminium Lugs of Ring Type Size – 150 mm Square 173 Aluminium Lugs of Ring Type Size – 185 mm Square 174 Aluminium Lugs of Ring Type Size – 240 mm Square 175 Aluminium Lugs of Ring Type Size – 300 mm Square 176 Becktol Red Varnish in Ltr. 177 Insulating Varnish in Ltr. 178 Cotton Tap 1” X 30 Meter in Rolls 179 Empire Tap 1” X 30 Meter in Rolls 180 HT Tap in Rolls 181 Water Proof Self Fusing Silicon Rubber Tao Electrical in Rolls 182 PVC TAP (Red, Yellow, Blue & Black) ¾” X 6.6 Meter 183 Pin Type Lamp Holder 184 3 Position Sensor Switch, HG-121C, 16 Amps. 185 Isolated Converters, 9000U SERIES 186 Isolated Converters, S1SD-1AI-2U 187 Isolated Converters, S1SD-1AI-1U 188 Proximity Sensor for Batch M/C(SW-4051-P0D1-B30(PNP- N0), 10-30V DC, SN DIST: 15mm, Load: 400MA 189 Carbon Brush Holder for 200 KW Crompton Make Motor for Carbon Brush 40X40X20 190 Carbon Brush for Leveller/Chopper Motor, KE14Z3 294285, 40X40X20 191 Carbon Brush for Chopper Motor M15E, 40X40X20 192 Carbon Brush for Cane Unloader Slip Ring Motor, P1903, 20X15X10 193 Brass Carbon Brush Holder Assembly for C.G.L Frama Size-132 (1 Set=3 No.) in Set 194 Carbon Brush for Air Blower In Set 195 Soldering Iron 60 Watt (Round and Pointed Flat- Tip) 196 Current Collector for Cane Unloaded 197 Complete Food Switch, 2 Step Type 198 Foot Switch Element 1 No-1NC
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
27.
Educational and Research Institute #9392647 Technical Bid
Supply Of Printed Books As Per Tender Document , Supply Of Printed Books , Heat Transfer/Binay K. Dutta/Phi Learning Private Limited/978-81-203-1625-6 , Stoichiometry And Process Calculations/K.V.Narayanan And B.Lakshmikutty/Phi Learning Private Limited/978-8120352896 , Elements Of Chemical Reaction Engineering/H. Scott Fogler/Phi Learning Private Limited/978-7502741006 , Chemical Reaction Engineering/Octave Levenspiel/Wiley/978-8126510009 , Mass Transfer Operations/Robert Treybal/Mcgraw Hill Education/N/A , Transport Processes And Separation Process Principles/Chistie John Geankoplis/Pearson Education India/N/A , Principles Of Mass Transfer And Separation Processes/Binay K. Dutta/Phi Learning Private Limited/N/A , Chemical Process Safety: Fundamentals With Applications /Daniel Crowl , Joseph Louvar/Pearson Education India/N/A , Transport Phenomena/R. Byron Bird, Warren E. Stewart, Edwin N. Lightfoot/Wiley/N/A , Chemical Process Control: An Introduction To Theory And Practice/George Stephanopoulos/Pearson/N/A , Process Systems Analysis And Control/Steven E Leblanc Donald R. Coughanowr/Mcgraw Hill Education/N/A , Chemical Engineering Design: Principles, Practice And Economics Of Plant And Process Design/Gavin Towler, Ray Sinnott/Butterworth-Heinemann Ltd/N/A , Plant Design And Economics For Chemical Engineers/Max Peters, Klaus Timmerhaus, Ronald West, Max Peters/Mcgraw Hill/N/A , Unit Operations Of Chemical Engineering/Warren Mccabe/Mcgraw Hill Education/N/A , Process Plant Simulation/B.V Babu/Oxford University Press/N/A , A Textbook Of Machine Design/R.S.Khurmi/S Chand/N/A , Mechanical Operations Fundamental Principles And Applications/Dr. Kiran D. Patil/Nirali Prakashan/N/A , Unit Operation -1/K. A. Gavhane/Nirali Prakashan/N/A , A Textbook Of Heat And Mass Transfer/Rk Rajput/S Chand/N/A , Numerical Methods For Engineers/Steven Chapra Raymond Canale/Mcgraw Hill Education/N/A , A Text Book Of Railway Engineering/Saxena S.C /Dhanpat Rai Publication/N/A , Adsorption Analysis: Equilibria And Kinetics (With Cd Containing Computer Matlab Programs): 2 (Series On Chemical Engineering)/ Duong D Do/Imperial College Press/978-1860941375 , Advanced Concrete Technology/Zongjin Li/John Wiley & Sons Ltd/978-0470437438 , Advanced Mechanics Of Solids/Srinath, L.S./Tata Mcgraw-Hill/978-0070139886 , Advanced Reinforced Concrete Design/Krishnaraju N/Cbs Publishers/978-8123929606 , Alkali-Aggregate Reaction And Structural Damage To Concrete /Geoffrey E Blight/Crc Press/978-1138073036 , An Introduction To The Finite Element Method/Reddy, J.N./Mcgraw Hill/978-9390385270 , Basic Structural Analysis/Reddy, C. S./Tata Mcgraw Hill/978-0070702769 , Classical And Computational Solid Mechanics/Fung,Tong And Chen/World Scientific Publishing Co Pte Ltd/978-0000988508 , Concrete Structures/Bhattacharjee J/Cbs Publishers/978-9385915901 , Concrete Structures Subjected To Impact And Blast Loadings And Their Combinations/Zhang Chunwei/Taylor & Francis Ltd/978-1032200514 , Concrete Technology/A M Neville/Pearson Education/978-8131705360 , Construction Materials Their Nature And Behaviour/Marios Soutsos, Peter Domone/Crc Press/978-1498741101864 , Design Of Reinforced Concrete Structures/Subramanian N/Oup India/978-0198086949 , Dynamics Of Structures/Clough,R.W. And Penzien, J/Mcgraw Hil/978-8123926636 , Elasticity And Plasticity: The Mathematical Theory Of Elasticity And The Mathematical Theory Of Plasticity/J.N. Goodier/Dover Publications Inc./ 978-0486806044 , Elements Of Strength Of Materials/Timosenko, S. P., And Young, D.H./Affiliated Eastwestpress Pvt. Ltd/978-8176710190 , Engineering Mechanics Of Solids/Popov, E.P./Pearson Education India/9332550216 , Environmental Engineering/Howard S Peavy, Donald R Rowe/Mcgraw Hill Education/978-9351340263 , Environmental Engineering (Vol. I) Water Supply Engineering/Santosh Kumar Garg/Khanna Publishers/978-8174091208 , Environmental Engineering (Vol. Ii) Sewage Waste Disposal And Air Pollution Engineering/Santosh Kumar Garg/Khanna Publishers/978-8174092304 , Finite Element Analysis: Theory And Programming/C. S. Krishnamurthy/Mcgraw Hill/978-0074622100 , Foundations Of The Theory Of Elasticity, Plasticity, And Viscoelasticity /Eduard Starovoitov And Faig Bakhman Ogli Naghiyev/Apple Academic Press Inc./978-1774631997 , Handbook Of Solid Waste Management/George Tchobanoglous, Frank Kreith /Mcgraw Hill Education/978-0071356237 , Highway Engineering/Khanna & Justo/Nemchand Publisher/8185240930 , Industrial Water Pollution Control/W Wesley Eckenfelder/Mcgraw Hill Education/978-9339220433 , Integrated Design And Environmental Issues In Concrete Technology/K Sakai/Crc Press/978-0367864620 , Intermediate Structural Analysis/Wang, C.K./Mcgraw Hill Education/978-0070702493 , Introduction To Solid Mechanics/Shames, H/Phi/978-9332549906 , Introduction To Traffic Engineering/R Srinivasa Kumar/The Orient Blackswan; South Asian Edition/9386235471 , Matrix And Finite Element Analysis Of Structures/Madhujit Mukhopadhay And Abdul Hamid Sheikh/Anebooks Pvt. Ltd./978-81-8052-075-4 , Microwave-Assisted Concrete Technology/Ong K.C. Gary/Crc Press/978-1138748897 , Prestressed Concrete /Krishnaraju N/Mcgraw Hill Education India/978-9387886209 , Principles Of Adsorption And Adsorption Processes/ Douglas M. Ruthven/Wiley-Interscience/978-0471866060 , Properties Of Concrete/A M Neville/Pearson Education/978-0273755807 , Random Vibrations Of Elastic Systems/Bolotin, V. V./Springer/978-9048182800 , Recent Trends In Solid Waste Management (Advances In Pollution Research)/Balasubramani Ravindran,Sanjay Kumar Gupta/Elsevier - Health Sciences Division/978-0443152061 , Reinforced Concrete: Mechanics And Design, Global Edition /Wight James/Pearson Education Limited/978-1292106007 , Soil Mechanics And Foundation Engineering - Geotechnical Engineering/K.R.Arora/Standard Publisher Dist/8180141128 , Solid Mechanics /Kazimi, S. M.A/Tata Mcgraw-Hill/978-0074517154: ? , Sprayed Concrete Technology/Simon Austin/Crc Press/978-0367865412 , Standard Methods For The Examination Of Water And Wastewater/William C. Lipps, Ellen Burton Braun-Howland, Terry E. Baxter/American Public Health Association/978-0875532998 , Statically Indeterminate Structures/Wang, C.K./Mcgraw Hill Book Company/978-9352604722 , Strength Of Materials/Srinath, L.S, Desayi./Macmillan Publishers India/978-0333923924 , Strength Of Materials, Part 1/Timoshenko, S/Mcgraw Hill/978-8123910307 , Strength Of Materials, Part 2/Timoshenko, S/Mcgraw Hill/978-8123910772 , Structural Dynamics/Mario Paz/Cbs Publications/978-8181287724 , Structural Dynamics- Theory And Application To Earthquake Engg/Anil K Chopra/Pearson Education/978-9353945251 , Structural Dynamics: Vibrations And Systems/Mukhopadhyaya, M./Ane Books /978-8180520907 , Sulfate Attack On Concrete/Jan Sklany/Taylor & Francis Ltd/978-0367447144 , Textbook Of Highway And Traffic Engineering/Saxena S.C /Cbs /978-8123924175 , The Finite Element Method Its Basis & Fundamentals/Zienkiewicz, Taylor And Zhu/Elsevier/978—81-312-118-2 , Theory Of Elasticstability/Timoshenko, S.P. And Gere, J. M./Tata Mcgraw Hill./978-0-07-0702417 , Theory Of Elasticity/Timoshenko And Goodier/Mcgraw Hill/978-0070701229 , Theory Of Elasticity And Plasticity: A Textbook Of Solid Body Mechanics/Antonina Molotnikova And Valentin Molotnikov /Springer Nature/978-3030666248 , Theory Of Plates And Shells/Timoshenko And Kriger/Tata Mcgraw Hill/978-0-07-070125-0 , Traffic & Highway Engineering/Nicholas J. Garber/Cengage India Private Limited/978-8131529430 , Traffic Engineering/R P. Roess (Author), Elena S. Prassas (Author), William R. Mcshane (Author)/Pearson Education/9353434858 , Wastewater To Water: Principles, Technologies And Engineering Design/Makarand M. Ghangrekar/Springer Verlag, Singapore/978-9811940507 , Soil Dynamics And Machine Foundations/Swami Saran/Galgotia Publication S Pvt. Ltd./978-8175157279 , Soil Mechanics And Foundation Engineering/K. R. Arora/Standard Publishers/978-8180141126 , Basic And Applied Soil Mechanics/Gopal Ranjan, Asr Rao/New Age International/9788122440393, , Design Of Steel Structures/N. Subramanian/Oxford University Press/978-0199460915 , Fundamental Concepts Of Earthquake Engineering /Roberto Villaverde/Crc Press/1420064959 , Civil Engineering Drawing /M Chakraborti// , Data Mining Concepts And Techniques /Jiawei Han, Jian Pei,Hanghang Tong/Elsevier/9788131267660 , Data Science In Practice/Tom Alby/Chapman & Hall/9781032505268 , Introduction To Data Science: Practical Approach With R And Python/B. Uma Maheswari, R. Sujatha/Wiley/9789354640506 , Transformers For Natural Language Processing And Computer Vision - Third Edition/Denis Rothman/Packt Publishing/9781805128724 , Generative Deep Learning/ David Foster/Oreilly Media/9781098134181 , Introduction To Machine Learning /Ethem Alpayd?N/Mit Press/9780262043793 , Data Mining With R/Luis Torgo/Taylor And Francis/9780367372453 , Bioinformatics And Functional Genomics/Jonathan Pevsner/Wiley Blackwell Pub/978-1118581780 , Bioinformatics Basics: Applications In Biological Science And Medicine/ Lukas K. Buehler/Crc Press/978-0367392598 , What Is The Name Of This Book?/Raymond M. Smullyan/Dover Publications Inc./978-0486481982 , The Lady Or The Tiger?/Raymond M. Smullyan/Dover Publications Inc./978-0486470276 , The Riddle Of Scheherazade: And Other Amazing Puzzles, Ancient And Modern./Raymond M. Smullyan/Knopf/978-0679446347 , Convex Optimization/Stephen Boyd, Lieven Vandenberghe/Cambridge University Press/978-0521833783 , Genetic Algorithms In Search, Optimization And Machine Learning/David E. Goldberg/Pearson/978-8131709931 , Steganography In Digital Media: Principles, Algorithms, And Applications/Jessica Fridrich/Cambridge/978-0521190190 , Deep Learning From Scratch: Building With Python From First Principles/Seth Weidman/Shroff/Oreilly/978-9352139026 , Wireless Communication Systems /Rajeshwar Dass./Wiley/978-9389583687 , Semiconductor Materials, Devices, And Fabrication, As Per Aicte/Parasuraman Swaminathan/Wiley/978-8126508624 , Introduction To 4G Mobile Communications/Juha Korhonen/Artech House Publishers/978-1608076994 , An Introduction To Lte/Cox Christopher/Wiley/978-1118818039 , Fourth Generation Mobile Communication/Curwen Peter/Springer International Publishing Ag/978-3319022093 , Advanced Wireless Communications: 4G Technologies/Savo G. Glisic/Wiley–Blackwell/978-0470867761 , 4G Wireless Communication Networks: Design Planning And Applications/Johnson I. Agbinya, Mari Carmen Aguayo-Torres, Ryszard Klempous/River Publishers/978-8792982711 , Fundamentals Of Lte/Rews, Rias Muhamed, Arunabha Ghosh, Jun Zhang, Jeffrey G./Pearson/978-9353062392 , 5G Mobile Communications/Wei Xiang, Kan Zheng, Xuemin (Sherman) Shen/Springer International Publishing Ag/978-3319342061 , 5G Mobile Core Network: Design, Deployment, Automation, And Testing Strategies/Rajaneesh Sudhakar Shetty/Springer India/978-1484283288 , 5G Mobile And Wireless Communications Technology/Afif Osseiran, Jose F. Monserrat, Patrick Marsch, Mischa Dohler, Takehiro Nakamura/Cambridge University Press/978-1107130098 , Towards 5G: Applications, Requirements And Candidate Technologies/Rath Vannithamby, Shilpa Talwar/Wiley/978-1118979839 , Fundamentals Of 5G Mobile Networks/Jonathan Rodriguez/Wiley/978-1118867525 , A Course In Electrical And Electronic Measurements And Instrumentation/A.K. Sawhney/Dhanpat Rai & Co. (P) Limited;/978-8177001006 , A Course In Electrical Machine Design/A.K. Sawhney/Dhanpat Rai & Co. (P) Limited /978-8177001013 , A Course In Electrical Technology (Basic Electrical Engineering Volume I)/J.B.Gupta/S.K. Kataria & Sons/81-85749-29-9 , A First Course On Electrical Drives/S.K.Pillai/New Age International Publishers/978-8122433616 , A Text Book Of Electrical Technology (Vol.1)/B.L.Theraja, A.K.Theraja/S.Chand Technical/9788121924405 , A Textbook Of Electrical Technology Volume Ii : Ac And Dc Machines/B.L.Theraja, A.K.Theraja/S Chand/978-8121924375 , Advanced Electrical Technology/H. Cotton/Reem Publications Pvt. Ltd. /978-8190630719 , An Integrated Course In Electrical Engineering/J.B.Gupta/S.K. Kataria & Sons/9-789350143681 , An Introduction To Analog And Digital Communication Systems/ Simon Haykin, Michael Moher /Wiley/978-8126536535 , An Introduction To The Principles Of Digital Communications/N.B.Chakraborti, A.K.Datta/New Age International Publishers/978-8122420838 , Analog Communication Systems/Sanjoy Sharma/S.K. Kataria & Sons/978-9350143797 , Artificial Intelligence And Intelligent Systems/N.P. Padhy/Oxford University Press/978-0195671544 , Artificial Neural Networks/B. Yegnanarayan/Prentice-Hall Of India Pvt. Ltd., New Delhi/ 978-8120312531 , Automatic Control System/ B. C. Kuo/ Prentice Hall Of India/9788120309685 , Automatic Control Systems (With Matlab Programs)/S. Hasan Saeed/Arihant Publisher/978-8190691925 , Basic Electrical Engg./D.P. Kothari & I.J. Nagrath/Mcgraw-Hill/9780070146112 , Basic Electrical Engg./V.K.Mehta, Rohit Mehta/S.Chand /978-8121908719 , Basic Electrical Engineering/A.E Fitzgerald, David E. Higginbotham, Arvin Grabel/ Mcgraw Hill Education/978-0070682566 , Circuit Theory (Analysis & Synthesis)/A.Chakraborti/Dhanpat Rai & Co./9788177000009 , Circuit Theory & Network/S. P. Ghosh And A. K. Chakraborty/Tata Mcgraw-Hill Education/9780071329040 , Communication Systems/Sekar, V. Chandra//978-0198078050 , Control System Engineering (Student Edition)/Norman Nise/John Wiley & Sons/978-8126537280 , Control Systems - I /S. Hasan Saeed/S.K. Kataria & Sons/978-9350141335 , Control Systems Engineering/I.J. Nagrath &M.Gopal/New Age International Pvt Ltd Publishers/9789386070111 , Design And Applications Of Analog Integrated Circuits/Soclof/Phi Learning Private Limited/978-81-203-2552-4 , Digital Communications/Sanjoy Sharma/S.K. Kataria & Sons/978-9350142684 , Digital Control Engineering/M. Gopal/New Age International Publishers/978-8122436617 , Digital Control Systems/B.C.Kuo/Oxford University Press/978-0198083542 , Digital Design/M. Morris Mano/Prentice Hall/978-0132774208 , Digital Electronics /G.K.Kharate/Oxford University Press/9-780198061830 , Digital Integrated Electronics/H. Taub And D. L. Schilling/Mcgraw Hill Education/978-0070265080 , Digital Signal Processing/Monson H Hayes/Tata Mcgraw - Hill Education/978-0070153868 , Digital Signal Processing/P.Ramesh Babu/Scitech Publications/978-8183710817 , Digital Signal Processing/B. Kumar/New Age International Publishers/978-8122436099 , Digital Signal Processing: A Computer Based Approach/S. K. Mitra/Mcgraw Hill Education/978-1259098581 , Direct Energy Conversion/Kettani, M. Ali/Addison-Wesley/ 97-80201036633 , Direct Energy Conversion/Stanley W. Angrist/Allyn And Bacon/978-0205077588 , Distributed Generation: Induction And Permanent Magnet Generators/Loi Lei Lai, Tze Fun Chan/Wiley/978-0470062081 , Distributed Generation: The Power Paradigm For The New Millennium/Anne-Marie Borbely, Jan F. Kreide/Crc Press/978-1420042399 , Electric And Hybrid Vehicles/Tom Denton/Routledge/9781138842373 , Electric Circuits /David. A. Bell/Oxford University Press/9780195694284 , Electric Energy Systems Theory-An Introduction/Olle I. Elgerd/Tata Mcgraw Hill/9780070992863 , Electric Machines/ I. J. Nagrath And D. P. Kothari/Tata Mcgraw Hill/978-0070699670 , Electrical Circuit Analysis (Including Passive Network Synthesis)/C.L.Wadhwa/New Age International Publishers/978-8122418521 , Electrical Engineering Fundamentals/Vincent Del Toro/Phi Learning Private Limited/978-8120305991 , Electrical Engineering Materials/T.K.Basak/New Age International Publishers/978-8122427738 , Electrical Machinery/Dr. P.S.Bimbhra/Khanna Publishers/978-8174091734 , Electrical Machinery /S. K. Sen/Khanna Publishers /978-8174091529 , Electrical Machines/R.K.Rajput/Laxmi Publications(P) Ltd./978-8131804469 , Electrical Machines /S.K.Bhattacharya/Tata Mcgraw-Hill Education/978-9332902855 , Electrical Measurements And Measuring Instruments/ E.W Golding, F.C Widdis/Reem Publications Pvt. Ltd/978-8190630726 , Electrical Power System Quality/R.C.Dugan/Tata Mcgraw-Hill Education, 2003/978-1259005572 , Electrical Power Systems/Ashfaq Husain/Cbs Publishers & Distributors/978-8123914480 , Electromagnetic Fields & Waves96/Sarwate V.V./New Age/81-224-0468-5 , Electromagnetic With Application/J. D. Krauss/Tata Mcgraw Hill/9780070702400 , Electromagnetics/B.B.Laud/New Age International Publishers/978-8122430554 , Electromagnetism – Theory And Applications/Ashutosh Pramanik/Prentice-Hall Of India/978-8120319578 , Electronic Devices And Circuit Theory/R. Boylestad And L. Nashelsky/Prentice Hall Publishing Co/978-0132504577 , Electronic Devices And Circuits/J. Millman And C. C. Halkias/Mcgraw Hill Education/978-0070423800 , Electronic Instrumentation/H.S.Kalsi/Mcgraw Hill Education/978-0070702066 , Elements Of Advanced Quantum Theory/J.M. Ziman/Camridge University Press/521-07458-4 , Elements Of Electrical Power Station Design/M.V.Deshpande/Prentice Hall India Learning Private Limited /978-8120336476 , Elements Of Photonics Vol-1 /Keigo Lizuka/Wiley-Interscince/0-471-83938-8 , Elements Of Power System Analysis/W.D. Stevenson/Mcgraw Hill Higher Education/978-0070665842 , Energy Economics: Concepts, Issues, Markets And Governance/Subhes C. Bhattacharyya/ Springer/978-1447174707 , Energy Science Principles, Technologies And Impact/J. Andrews, N. Jelley/Oxford University Press/978-0198755814 , Energy Technology - Nonconventional, Renewable & Conventional/S.Rao, Dr. B.B.Parulekar/Khanna Publishers/97-88174090401 , Energy Technology (Non Conventional, Renewable And Conventional)/Prof. Sunil S. Rao And Dr. B.B. Parulekar/Khanna Publishers/978-81-7409-040-9 , Engineering Circuit Analysis/W. H. Hayt , J. Kemmerly /Mcgraw Hill Education/978-1259098635 , Engineering Electromagnetic/W. H. Hayt & J. A. Buck/Mcgraw-Hill/978-9353169725 , Engineering Electromagnetics/Hayat/Tmh/0-07-061223-4 , Engineering Optimization Theory And Practice/Singiresu S. Rao/New Age International Publishers/978-8122427233 , Engineering Thermodynamics/P.K.Nag/ Mcgraw Hill Education/978-9352606429 , Explanations / Solutions To An Integrated Course In Electrical Engineering (With About 15,000 Objective Type Questions & Answers) /J.B.Gupta/S.K. Kataria & Sons/978-9350146668 , Facts Controllers In Power Transmission And Distribution/K.R. Padiyar/New Age International Publishers/978-8122421422 , Fiber Optics Essentials/K. Thyagarajan & Ajoy Ghatak/Wiley-Interscince/978-0-470-09742-7 , Fiber Optics Through Experiments Paperback – 2011/Ajoy Ghatak, M. R. Shenoy /Viva Books (2011)/978-8130918112 , Fiber-Optic Communication Systems/Govind P. Agrawal/Wiley/978-8126513864 , Fibre Optics And Optoelectronics/R.P.Khare/Oxford University Press/9-780195669305 , Flexible Ac Transmission Systems/Yong Hua Song, Allan T. Johns/ Laxmi Publications /978-8190858809 , Fundamentals Of Digital Circuits/A. Anand Kumar/Prentice-Hall Of India Pvt. Limited/978-8120352681 , Fundamentals Of Electric Circuits/Charles K. Alexander, Matthew N. O. Sadiku/Mcgraw Hill Education (India) Private Limited/978-9355320162 , Fundamentals Of Microprocessors And Microcontrollers/B. Ram/Dhanpat Rai Publications (P) Ltd/978-9383182107 , Fundamentals Of Optical Wave Guides/Katsunari Okamoto/Elsevier/978-0-12-525-096-2 , Fundamentals Of Photonics /Bahaa E. A. Saleh, Malvin Carl Teich/ John Wiley & Sons, Inc./0-471-2-1374-8 , Fundamentals Of Power Electronics/Robert W. Erickson, Dragan Maksimovic/Springer Us/978-1-4757-0559-1 , Generation Distribution And Utilization Of Electrical Energy/C.L. Wadhwa/New Age International Publishers/978-8122428216 , Getting Started With Matlab/Rudra Pratap/Oxford University Press/978-0198069195 , Goldings Electrical Measurements And Measuring Instruments/Golding & Widdis/Medtech Publishers/978-9387210349 , Handbook Of Energy Conservation, Vol. 1/H.M. Robert, J.H. Collins/Cbs Publishers & Distributors/9-788123912066 , Handbook Of Energy Conservation, Vol. 2/H.M. Robert, J.H. Collins/Cbs Publishers & Distributors/9-788123912073 , High Voltage Engineering/C.L.Wadhwa/New Age International Publishers/978-8122430905 , High Voltage Engineering/M.S Naidu & V Kamaraju/Mcgraw Hill Education/978-1259062896 , High Voltage Engineering: Problems & Solutions/R.D. Begamudre/New Age International Publishers/978-8122426182 , Hvdc Power Transmission Systems/K.R. Padiyar/New Age International Publishers/978-8122437850 , Industrial Energy Conservation Techniques : Concepts, Applications And Case Studies /K. Nagabhushan Raju/Atlantic Publishers And Distributors (P) Ltd/978-8126907748 , Industrial Instrumentation/Donald P. Eckman/Cbs Publisher/978-8123908106 , Industrial Instrumentation/K.Krishnaswamy, S. Vijayachitra/New Age International Publishers/978-8122427509 , Industrial Instrumentation, Control And Automation/Mukhopadhay, Sen & Deb/Jaico Publishing House/978-8184954098 , Instrumentation And Control/Patranabis/Phi Learning Private Limited/978-81-203-4246-0 , Introduction To Digital Signal Processing/J.R. Johnson/ Prentice Hall India Learning Private Limited /978-8120307605 , Introduction To Fiber Optics (English) 1St Edition/Ajoy Ghatak , K. Thyagarajan/Cambridge University Press-New Delhi/97-88175960626 , Introduction To Quantum Mechanics/David J. Griffiths/Prentice Hall/0-13-124405-1 , Introduction To Quantum Mechanics/A.C. Philips/John Wiley & Sons, Inc./0-470-85323-9 , Introduction To Solid State Physics/ Charles Kittel /Wiley & Sons/978-8126535187 , Lasers And Non-Linear Optics/B.B.Laud/New Age International Publishers/978-8122430561 , Linear Integrated Circuits/D. Roy Choudhury, Shail B. Jain/New Age International Publishers/978-8122430981 , Matrix Analysis Of Electrical Machines/Ashoke Kumar Mukhopadyhay/New Age International Publishers/978-8122432398 , Microcomputer Systems: The 8086/8088 Family/I. Liu, G. A. Gibson/ Prentice Hall India Learning Private Limited/978-8120304093 , Microelectronic Circuits: Theory And Applications/A.S. Sedra And K.C. Smith/Oxford University Press/978-0199476299 , Microelectronics/J. Millman And A. Grabel/Mcgraw Hill Education/978-0074637364 , Microprocessor Architecture, Programming And Applications With The 8085A/8080A/Ramesh S. Gaonkar/Wiley Eastern Ltd./978-0852262979 , Microprocessors Interfacing/Douglas Hall/Mcgraw Hill Education/978-1259006159 , Modern Digital And Analog Communication Systems/B.P.Lathi/Oxford University Press/978-0198073802 , Modern Electronic Instrumentation And Measurement Techniques /A D Helfrick; W D Cooper/ Prentice Hall India Learning Private Limited/?978-9332556065 , Modern Power System Analysis/I.J. Nagrath And D.P. Kothari/Mcgraw Hill Education/978-0071077750 , Modern Quantum Mechanics /J.J.Sakurai/Addison -Wesley Publishing Company/0-201-53929-2 , Network Analysis And Synthesis/S. P. Ghosh And A. K. Chakraborty/Tata Mcgraw-Hill Education/9781259081422 , Network Analysis And Synthesis/Franklin F. Kuo /Wiley/978-8126510016 , Network Analysis And Synthesis (Including Linear System Analysis)/C.L.Wadhwa/New Age International Publishers/978-8122420364 , Networks And Systems/D. Roy Choudhury/New Age International Publishers/978-8122427677 , Neural Networks In Computer Intelligence /F. Limin/Mcgraw Hill Education/978-0070532823 , Neural Networks, Fuzzy Logic And Genetic Algorithms: Synthesis And Applications/S. Rajasekaran And G.A. Vijaylakshmi Pai,/Prentice-Hall Of India Pvt. Ltd., New Delhi/978-8120321861 , Non Conventional Energy Resources/D.S. Chauhan, S.K.Srivastava/New Age Int.(P) Ltd/978-81-224-3399-9 , Non-Conventional Energy Resources/B.H. Khan/Tata Mcgraw Hill/978-0070142763 , Non-Conventional Energy Resources/D.S. Chauhan/New Age International Publishers/978-8122433999 , Non-Conventional Energy Sources/G.D. Rai/Khanna Publishers/9-788174090737 , Nonlinear Fiber Optics/Govind P. Agrawal/Optics And Photonics/N/A , Nonlinear Optics /Robert W. Boyd/Academic Press/0-12-121682-9 , Objective Electrical Technology/V.K.Mehta, Rohit Mehta/S. Chand Publishing/978-9355014467 , Op-Amps And Linear Integrated Circuits/Gayakwad/Phi Learning Private Limited/978-81-203-2058-1 , Operational Amplifiers And Linear Ics/David. A. Bell/Oxford University Press/978-0195696134 , Optical Electronics /A.K.Ghatak & K.Thyagarajan/Camridge University Press/0-521-30643-4 , Optical Waves In Crystals/Amnon Yariv & Pochi Yeh/Wiley-Interscince/0-471-09142-1 , Optimization Of Power System Operation/Jizhong Zhu/Wiley/978-1-118-85415-0 , Parker Smiths 500 Solutions Of Problems In Electrical Engineering (Part 1)/V.C Nateshan/Cbs /N/A , Performance And Design Of Ac Machines/M. G. Say/Cbs Publishers/978-8123910277 , Photonics/Amnon Yariv & Pochi Yeh/Oxford University Press/978-0-19-517946-0 , Power Electronics/Dr. P. S. Bhimbra/Khanna Publisher/978-81-7409-279-3 , Power Electronics: Converters, Applications, And Design/Ned Mohan, Tore M. Undeland, William P. Robbins/Wiley India/978-8126510900 , Power Electronics: Devices, Circuits And Applications/Muhammad H Rashid/Pearson Education/978-9332584587 , Power Electronics: Essentials & Applications/L. Umanand/Wiley/978-8126519453 , Power Generation, Operation, And Control/Allen J. Wood, Bruce F. Wollenberg/John Wiley & Sons/978-8126508389 , Power Plant Engineering/Arora & Domkundwar/Dhanpat Rai & Co. (P) Limited/978-8177001952 , Power Plant Engineering/A.K.Raja, Amit Prakash Srivastava, Manish Dwivedi/New Age International Publishers/978-8122418316 , Power Plant Technology/M.M.El-Wakil/Mcgraw Hill Education/978-0070702448 , Power System Analysis/J.J.Grainger, W.D.Stevenson/Tata Mcgraw-Hill/978-0070612938 , Power System Analysis: Operation And Control/ Abhijit Chakrabarti, Sunita Halder/Phi Learning Pvt. Ltd./ 978-8120340152 , Power System Optimization: Stability And Control/K. R. Padiyar/Anshan Ltd./978-1904798019 , Power System Optimization/D .P. Kothari And J.S Dhillon/Prentice Hall India Learning Private Limited/?978-8120340855 , Power System Prorection And Switchgear/B. Ravindranath And M. Chander/New Age International Publishers/978-8122430325 , Power System Protection/S. P. Patra, S. K. Basu, S. Choudhuri/Oxford & Ibh Publishing Co./N/A , Power System Protection And Communications/Akhter Kalam/New Age International Publishers/978-8122427417 , Power System Protection And Swichgear/B. Ravindranath, M. Chander/New Age International Publishers/978-8122430325 , Power System Restructuring And Deregulation/Loi Lei Lai/John Wiley & Sons Ltd /978-8126547234 , Power System Stability Vol-I/E.W.Kimbark/John Wiley & Sons/978-8126512577 , Power System Stability And Control/Prabha Kundur/Tata Mcgraw-Hill Education Private Limited/978-0070635159 , Power System Stability Vol-Ii/E.W.Kimbark/John Wiley & Sons/978-8126512577 , Power Systems Analysis/ Arthur Bergen, Vijay Vittal / Pearson/978-0136919902 , Principles Of Electromagnetics/Matthew N.O. Sadiku/Oxford University Press/9780198062295 , Principles Of Electronic Instrumentation/Patranabis/Phi Learning Private Limited/978-81-203-3355-0 , Principles Of Industrial Instrumentation/D. Patranabis/Mcgraw Hill Education/978-0070699717 , Principles Of Power Systems/V.K.Mehta, Rohit Mehta/S.Chand & Co./978-8121924962 , Principles Of Process Control/ D. Patranabis/Tata Mcgraw Hill/978-0071333252 , Principles Of Signal Processing And Linear Systems/B.P.Lathi/Oxford University Press/978-0198062288 , Problems And Solutions In Power Systems/Abhijit Chakrabarti /Abhijit Chakrabarti /978-9334032581 , Problems In Electrical Engineering(Power Engineering And Electronics With Answers Partly Solved In S.I. Units)/N. N. Parker Smith/Cbs Publisher/978-8123908588 , Process Control (Concepts, Dynamics & Applications)/S.K.Singh/Phi Learning Private Ltd./978-8120336780 , Process Control (Principles & Applications)/Surekha Bhanot/Oxford University Press/978-0195693348 , Process Dynamics And Control/D.E. Seborg, T.F. Edgar And D.A. Mellichamp/Wiley/978-8126541263 , Process Systems Analysis And Control/D.R. Coughanowr And L.B. Koppel/Mcgraw-Hill/978-0070851122 , Pulse Width Modulation For Power Converters: Principles And Practice/D. Grahame Holmes, Thomas A. Lipo/Wiley Ieee Press/978-0-471-20814-3 , Quantum Optics/Harry Paul/Camridge University Press/978-0-511-19475-7 , Reliability And Life Estimation Of Power Equipment/T.S.Ramu And Chakradhar Reddy/New Age International Publishers/978-8122426113 , Renewable Energy For Sustainable Future/Godfrey Boyle/Oxford University Press/978-0199681273 , Research Insights: A Handbook On Grant Writing And Program Management/ Rajiv K. Tayal/Atlantic Publishers And Distributors Pvt Ltd./978-8126935451 , Semiconductor-Laser Fundamentals/Weng W. Chow & Stephen W. Koch/Springer/3-540-64166-1 , Sensors And Transducers/Patranabis/Phi Learning Private Limited/978-81-203-3355-0 , Signals And Systems/H. P. Hsu/Mcgraw Hill Education (India) Private Limited/978-0070669185 , Signals And Systems/A.V. Oppenheim, Schafer, R. W, A.S. Willsky And I.T. Young/ Pearson Education India/9332550239 , Smart Grid Technology And Application/Janaka Ekanayake, Kithsiri Liyanage, Jianzhong Wu, Akihiko Yokoyama And Nick Jenkins/Wiley Publications/978-0-470-97409-4 , Smart Grid: Concepts To Design/K. S. Manoj/Notion Press/9781646780006 , Smart Grid: Fundamental Of Design And Analysis/James Momoh/Wiley Publication/978-8126558124 , Solar Cell Device Physics/Stephen Fonash/Academic Press/978-0080912271 , Solar Cells: Operating Principles, Technology, And Systemapplications/Martin A. Green/Prentice-Hall/978-0138222703 , Solar Electricity Generation/S. Bhattacharjee/ Narosa Publishing House/97-88184874044 , Solar Energy/S.P. Sukhatme, J K Nayak/Tata Mcgraw Hill/978-9352607112 , Solar Photovoltaics: Fundamentals, Technologies And Applications/Chetan Singh Solanki/Phi Learning/978-8120351110 , Solid State Physics/A.J. Dekker/ Macmillan/978-0333106235 , Solid State Physics/ S.O. Pillai /New Age International Private Limited/978-9389802313 , Sustainable Energy Management/Mirjana Radovanovi? (Golusin),Stevan Popov,Sinisa Dodic /Elsevier/978-0124159785 , Taubs Principles Of Communication Systems /H. Taub And D.L. Shilling/Mcgraw Hill Education/978-0070648111 , The 8051 Microcontroller And Embedded Systems/Muhammed Ali Mazidi And Janice Gillispie Mazidi/Pearson Education India/978-0138610227 , The Theory Of Optics/Paul Drude/Longmans, Green & Co./N/A , Theory & Performance Of Electrical Machines/J.B.Gupta/S.K. Kataria & Sons/978-9350142776 , Thermal Engineering/R.K.Rajput/ Laxmi Publications/978-8131808047 , Understanding Facts: Concepts And Technology Of Flexible Ac Transmission Systems/Narain G. Hingorani, Laszlo Gyugyi/Wiley India Pvt Ltd./978-8126530403 , Signals And Systems /Ramesh Babu/Scitech Publications/978-81-8371-288-0 , Fundamentals Of Industrial Instrumentation /Barua/Wiley India/9788126528820 , Bioinstrumentation /Fulekar/Wiley India/9789389520286 , Wileys Gate Instrumentation Engineering Chapter-Wise Solved Papers (2000-2020)/Gupta/Wiley India/9788126558698 , Electronic Measurement & Instrumentation /Imam/Wiley India/9789389583021 , Electrical Measurements And Measuring Instruments/Kamakshaiah/Wiley India/9789389447521 , A Treatise On Instrumentation Engineering /Padmanabhan/Wiley India/9789389633832 , Instrumentation And Process Control /Prasad/Wiley India/9789389307191 , Biomedical Electronics And Instrumentation Made Easy /Sawhney/Wiley India/9789389795943 , Medical Instrumentation 5Ed: Application And Design, An Indian Adaptation /Webster/Wiley India/9789354249150 , Lasers And Optical Instrumentation /Nagabhushana/Wiley India/9789389698756 , Automatic Control Engineering /Gupta/Wiley India/9789389583748 , Power System Analysis: Operation And Control, 2Ed/Jena/Wiley India/9789389520415 , Process Control Engineering /Krishna/Wiley India/9789389633429 , Quality Control/Kulkarni/Wiley India/9788126519071 , Control Engineering/Kuttan/Wiley India/9789389520064 , Digital Control, W/Cd /Moudgalya/Wiley India/9788126522064 , Nises Control Systems Engineering, Wiley India Ed/Nise/Wiley India/9788126571833 , Control Systems /Padmanabhan/Wiley India/9789389633375 , Control Engineering/Ramachandran/Wiley India/9788126522880 , Power System: Operation & Control/Rao/Wiley India/9788126534418 , Matlab With Control System, Signal Processing And Image Processing Toolboxes, W/Cd /Sivanandam/Wiley India/9788126554751 , Statistical Quality Control: A Modern Introduction, 6Ed /Montgomery/Wiley India/9788126525065 , Robotics /Appu/Wiley India/9789389583281 , Fuzzy Sets And Fuzzy Logic With Engineering Applications, 4Ed, An Indian Adaptation /Rose/Wiley India/9788126502608 , Natural Language Processing/Kumar/Wiley India/9789389307597 , Optimization Techniques /Malik/Wiley India/9789389698725 , Artificial Intelligence For Dummies/Mueller/Wiley India/9788126576104 , Big Data Analytics Using Artificial Intelligence Technologies /Dixit/Wiley India/9789391029685 , Artificial Intelligence: Concepts And Applications /Goel/Wiley India/9788126519934 , Artificial Intelligence: Making A System Intelligent /Jain/Wiley India/9788126579945 , Artificial Intelligence/Kumar/Wiley India/9789389795134 , Process Dynamics And Control, 4Edan Indian Adaptation /Seborg/Wiley India/9789354248429 , Digital Control/Moudgalya/Wiley India/9788126522064 , An Advanced Approach To Data Interpretation For Competitive Examinations/R.S. Aggarwal/S Chand Publishing/978-9358702330 , Quantitative Aptitude For Competitive Examinations/R.S. Aggarwal/S Chand Publishing/978-9355012326 , Modern Approach To Verbal & Non-Verbal Reasoning/R.S. Aggarwal/S Chand Publishing/978-9355011534 , Objective General English/R.S. Aggarwal/S Chand Publishing/978-9355015075 , The Magic Of The Lost Temple/Sudha Murty/Penguin Books India/978-0143333166 , Samsara: Enter The Valley Of The Gods/Saksham Garg/Penguin/978-0143458289 , The Mountain Is You: Transforming Self-Sabotage Into Self-Mastery/Brianna Wiest/Amaryllis/978-9355434142 , I Dont Love You Anymore: Moving On And Living Your Best Life/Rithvik Singh/Ebury Press/978-0143469131 , Ancient India/Rs Sharma/Old Ncert/N/A , History Of Medieval India/Satish Chandra/Old Ncert/N/A , A Brief History Of Modern India/Spectrum Publications/Spectrum/N/A , India’S Struggle For Independence/Bipan Chandra/Penguin/N/A , Certificate Physical And Human Geography/G.C. Leong/Oxford University Press/N/A , India: A Comprehensive Geography/D.R. Khullar/Kalyani Publishers/N/A , Indian Polity/M. Laxmikanth/Mcgraw Hill/N/A , Indian Economy/Ramesh Singh/Mcgraw Hill/N/A , Environment/Shankar Ias/Shankar Ias Academy/N/A , Indian Art And Culture/Nitin Singhania/Mcgraw Hill/N/A , Disaster Management/R. Subramanian/Vikas Publishing/N/A , Internal Security/M.Karthikeyan/Tata Mcgraw Hill/N/A , Lexicon For Ethics, Integrity & Aptitude/Niraj Kumar/Pearson/N/A , Ethics, Integrity, And Aptitude/Subba Rao And P.N. Roy Chowdhury/Access Publishing/N/A , Principles Of Mathematical Analysis/Walter Rudin/Mcgraw-Hill Education/978-0070856134 , Real And Complex Analysis/Walter Rudin/Mcgraw Hill Education/978-0070619876 , Functional Analysis/Walter Rudin/Mcgraw Hill Education/978-0070619883 , Mathematical Analysis/Tom M. Apostol /Narosa/978-8185015668 , Real Analysis/Royden/Pearson Education India/978-9332551589 , Analysis I/Terence Tao/Hindustan Book Agency/978-9380250649 , Complex Analysis/Ahlfors L V/Mcgraw Hill/978-1259064821 , Complex Variables And Applications/James Ward Brown, Ruel V. Churchill/Mcgraw Hill/978-9354600364 , Functions Of One Complex Variable I/John B. Conway/Springer/978-0387903286 , Algebraic Topology/Allen Hatcher /Cambridge University Press/978-0521795401 , Topology/James Munkres/Pearson Education/978-9353432775 , Introduction To Topology And Modern Analysis /George Simmons/Mcgraw Hill Education/978-0070597846 , Introduction To Analytic Number Theory/Tom M. Apostol /Springer/978-1-4419-2805-4 , Topology Of Metric Spaces/S. Kumaresan/Narosa/978-81848705 , Topics In Algebra/I.N. Herstein/Wiley/978-8126510184 , Algebra/M Artin/Pearson Education India/978-9332549838 , Abstract Algebra/David S. Dummit, Richard M. Foote/Wiley/978-8126532285 , A First Course In Abstract Algebra/J.B. Fraleigh/Narosa Publishing House Pvt Ltd/978-8185015705 , Contemporary Abstract Algebra/Joseph A Gallian/Cengage India Private Limited/978-9353502522 , Linear Algebra/Kenneth M Hoffman And Ray Kunze/Prentice Hall India Learning Private Limited/978-9332550070 , Matrix Analysis/Roger A. Horn, Charles R. Johnson/Cambridge University Press/978-0521548236 , Topics In Matrix Analysis/Charles R. Johnson, Roger A. Horn/Cambridge University Press/978-0521467131 , Matrix Analysis/Rajendra Bhatia/Springer/978-0387948461 , Introduction To Linear Algebra/Gilbert Strang /Wellesley-Cambridge Press/978-09802327-7-6 , Linear Algebra And Learning From Data/Gilbert Strang/Wellesley-Cambridge Press/978-06921963-8-0 , Linear Algebra: A Geometric Approach/S. Kumaresan/Prentice Hall India Learning Private Limited/978-8120316287 , Differential Equations/Shepley L. Ross /Wiley/978-8126515370 , Theory Of Ordinary Differential Equations/Earl Coddington, Norman Levinson/Mcgraw Hill Education/978-0070992566 , Differential Equations: Theory - Technique And Practice /George Simmons/Mcgraw Hill Education/978-0070616097 , Introduction To Graph Theory/West/Pearson Education India/978-9332549654 , Graph Theory/Frank Harary/Narosa Publishing House/978-8185015552 , Spectral Graph Theory/Fan R. K. Chung/American Mathematical Society/978-0821803158 , Graphs And Matrices/Ravindra B. Bapat/Springer London Ltd/978-1848829800 , Spectra Of Graphs/Andries E. Brouwer, Willem H. Haemers/Springer/978-1489994332 , The Feynman Lectures On Physics Vol 3/Richard P. Feynman/Addison-Wesley/978-8185015842 , Quantum Computation And Quantum Information/M. A. Nielsen And I. L. Chuagn/Cambridge University Press/978-1107619197 , Principles Of Quantum Computation And Information: A Comprehensive Textbook/Giuliano Benenti, Giulio Casati/World Scientific Publishing Co Pte Ltd/978-9813279995 , Quantum Computing Explained/David Mcmahon/Wiley-Ieee Computer Society Pr/978-0470096994 , Coding Theory: A First Course/San Ling/Cambridge English/978-1108717540 , Elements Of Information Theory/Joy A. Thomas Thomas M. Cover/Wiley/978-8126541942 , First Course In Information Theory/Raymond W. Yeung/Springer Low Price Edition/978-8184897036 , Machine Learning: A Probabilistic Perspective/Kevin P. Murphy /The Mit Press/978-0262018029 , Introduction To Data Mining/Pang-Ning Tan Michael Steinbach Anuj Karpatne Vipin Kumar/Pearson/978-9354491047 , Data Warehousing: Fundamentals For It Professionals/Paulraj Ponniah/Wiley/978-8126537297 , An Introduction To Probability Theory And Its Applications Vol I/William Feller/Wiley/978-8126518050 , An Introduction To Probability Theory And Its Applications Vol Ii/William Feller/John Wiley & Sons Inc/978-8126518067 , A Textbook Of Algebra/Sudesh K Shah, Subhash Chand Garg/S.Chand/978-9352710829 , Introduction To Differential Geometry Of Space Curves And Surfaces/Taha Sochi/Create Space/1546735895 , Differential Geometry Of Manifolds/U. C. De, A. A. Shaiks/Narosa Publisher/ 978-8173197772 , Differential Geometry Of Manifolds/Lovett Stephen/Taylor & Francis Ltd/978-0367180461 , Adventures In Stochastic Processes/Sidney I. Resnick/Springer Science & Business Media/978-1461203872 , Statistical Methods/Kapil Sharma/Oxford Book Co./978-9350304693 , Statistics For Business And Economics/Dr. G.P. Yadav/Oxford Book Co./8185771545 , Statistics For Management /Ashish J. Dave/Oxford Book Co./978-9350300732 , Statistics For Management And Economics/Dr. G.P. Yadav/Oxford Book Co./978-8183765688 , Strategic Methods And Concepts Of Statistics/R.K. Jacob/Oxford Book Co./978-8183765800 , Vector Calculus/Dr. Rakesh Kumar Pandey/Oxford Book Co./978-9350304716 , A Course Of Mathematical Analysis/P K Mittal & /S.Chand/978-8121904728 , A Textbook Of Algebra/Subhash Chand Garg /S.Chand/978-9352710829 , A Textbook Of Discrete Mathematics/Dr. Swapan Kumar Sarkar/S.Chand/9788121922326 , A Textbook Of Vector Analysis/P K Mittal & /S.Chand/9788121922432 , A Textbook On Dynamics/M Ray & G C Sharma/S.Chand/9788121903424 , Advanced Differential Equations/Dr. M.D. Raisinghania/S.Chand/9788121908931 , Analytical Solid Geometry/P K Mittal & Shanti Narayan/S.Chand/9788121926614 , Applied Mathematics/N C Srinivas & Ch V Ramana Murthy/S.Chand/9788121920827 , Differential Calculus/Shanti Narayan & P K Mittal/S.Chand/9788121904711 , Differential Calculus For Competetions/Shanti Narayan/S.Chand/978-8121925136 , Dynamics/Dr. M.D. Raisinghania/S.Chand/978-8121926492 , Elementary Statistics/H C Saxena/S.Chand/978-8121909259 , Elements Of Real Analysis/Dr. M.D. Raisinghania & Shanti Narayan/S.Chand/9788121903066 , Experimental Statistics/Dr. K. Balaji/S.Chand/9788121935661 , Fourier Series And Integral Transforms/Dr. V. Ramesh Babu & S. Ranganatham/S.Chand/9789384319090 , Integral Calculus/P K Mittal & Shanti Narayan/S.Chand/9788121906814 , Integral Calculus For Competetion/P K Mittal & Shanti Narayan/S.Chand/9788121925358 , Integral Equations And Boundary Value Problems/Dr. M.D. Raisinghania/S.Chand/9788121928052 , Mathematical Statistics/J. N. Kapur & H.C. Saxena/S.Chand/9788121912464 , Mathematics For Degree Students/Dr. U.S. Rana/S.Chand/9788121941013 , Algebraic Topology: An Introduction/Naseer Khan/Oxford Book Co./978-9350303344 , Analysis On Manifolds: A Modern Approach To Mathematics & Physics/V.G. Gupta/Oxford Book Co./978-9350304242 , Applied Combinatorics /Luis J. Green/Oxford Book Co./978-9350304556 , Applied Partial Differential Equations/Dr. F.D. Wade/Oxford Book Co./978-8189473433 , Applied Statistics For Economics And Business/G.P. Gupta/Oxford Book Co./978-9350303825 , Basics Of Bioinformatics/Narayan Dubey/Oxford Book Co./978-9383096893 , Business Statistics For International Trade/Ashish J. Dave/Oxford Book Co./978-9383101030 , Calculus For Computer Graphics/Gopal Narayan/Oxford Book Co./978-9383096916 , Calculus With Vectors/Luis J. Green/Oxford Book Co./978-9383096053 , Computing Fundamentals/Gopal Narayan/Oxford Book Co./978-9350304624 , Elementary Bioinformatics/Dr. Satish Kumar Sinha/Oxford Book Co./978-9350304266 , Environmental Statistics With R/Dr. Manendra Kumar/Oxford Book Co./978-9350301333 , Essential Statistics For Business And Economics/Ashish J. Dave/Oxford Book Co./978-9383096176 , Essentials Of Bioinformatics/Dr. Ashish Gulwe/Oxford Book Co./978-9350303603 , Fuzzy Logic, Neural Network And Genetic Algorithms Handbook/Jan Bundschuh/Oxford Book Co./978-9383096039 , Handbook Of Bioinformatics/S.G. Sandhu/Oxford Book Co./978-8193470404 , Mathematical Logic/Dr. Savita Mishra/Oxford Book Co./978-9350304532 , Mathematical Modelling/Naseer Khan/Oxford Book Co./978-9382629733 , Mathematical Physics/Hilary D. Brewster/Oxford Book Co./978-9350303412 , Optimization Theory: Techniques Of Operation Research/V.G. Gupta/Oxford Book Co./978-9350304334 , Mechanics/Muthamizh Jayapragasam, Laxmi Duraipandian/S.Chand/9788121902724 , Ordinary And Partial Differential Equations/Dr. M.D. Raisinghania/S.Chand/9788121908924 , Probability And Quening Theory/P Kandasamy & /S.Chand/9788121923569 , Theory Of Functions Of A Complex Variable/P K Mittal & Shanti Narayan/S.Chand/9788121906395 , Vector Algebra/P K Mittal & Shanti Narayan/S.Chand/9788121909525 , Vector Analysis/Kayalal Pachaiyappa & P Duraipandian/S.Chand/9789384319694 , Statics/Md Motiur Rahman/New Central Book Agency Pvt. Ltd./978-8173810275 , Rigid Dynamics/Md Motiur Rahman/New Central Book Agency Pvt. Ltd./978-8173812248 , Higher Algebra[Classical And Modern]/Ram Krishna Ghosh/New Central Book Agency Pvt. Ltd./978-8173811043 , Numerical Analysis With Elements Of Computer Science/Apurba Narayan Das/New Central Book Agency Pvt. Ltd./978-8173817557 , Mathematical Analysis/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./978-8173817809 , Numerical Analysis/Kalyan Mukherjee/New Central Book Agency Pvt. Ltd./978-8173815201 , Linear Programming And Theory Of Games/Pyari Mohan Karak/New Central Book Agency Pvt. Ltd./978-8173814051 , Analytical Geometry And Vector Algebra/Ratan Mohan Khan/New Central Book Agency Pvt. Ltd./9788-173810169 , Analytical Dynamics Of A Particle Including Elements Of Statics/Shambhunath Ganguly/New Central Book Agency Pvt. Ltd./9788-173811630 , Differential Equations With Introduction To Laplace Transform/Apurba Narayan Das/New Central Book Agency Pvt. Ltd./978-8173816635 , Numerical Methods Practical/Shyamapada Dutta/New Central Book Agency Pvt. Ltd./978-8173815645 , A First Course On Operations Research And Information Theory/Sanat Kumar Mazumder/New Central Book Agency Pvt. Ltd./978-8173818844 , Advanced Business Mathematics And Statistics/Ram Krishna Ghosh/New Central Book Agency Pvt. Ltd./978-8173816741 , Engineering Mathematics/Rajkumar Roychoudhury/New Central Book Agency Pvt. Ltd./978-8173810909 , Analytical Dynamics Of A Particle/Sambhunath Ganguly/New Central Book Agency Pvt. Ltd./978-8173810497 , Integral Calculus/Kantish Ch Maity/New Central Book Agency Pvt. Ltd./97-88173817328 , Introduction To Number Theory/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./97881-73815867 , Mathematics And Statistics/Suranjan Saha/New Central Book Agency Pvt. Ltd./97881-73811838 , Mathematical Probability/Kartick Chandra Pal/New Central Book Agency Pvt. Ltd./978-8173817816 , Differential Geometry/Fr F Goreux/New Central Book Agency Pvt. Ltd./978-8173815669 , Introduction To Tensor Calculus/Fr F Goreux/New Central Book Agency Pvt. Ltd./9788-173818516 , Vector Analysis Tensor Analysis And Linear Vector Space/S P Kuila/New Central Book Agency Pvt. Ltd./9789-352550333 , Introduction To Discrete Mathematics/M K Sen/New Central Book Agency Pvt. Ltd./97881-87134886 , Topics In Mathematics/Sandip Banerjee/New Central Book Agency Pvt. Ltd./97881-87134466 , Advanced Linear Programming & Game/A Mukherjee/New Central Book Agency Pvt. Ltd./97893-84294083 , Application Of Calculus/Debasish Sengupta/New Central Book Agency Pvt. Ltd./97881-87134626 , Analytical Statics/S A Mollah/New Central Book Agency Pvt. Ltd./97893-84294427 , Basic Concepts Of Numerical Methods, Probability And Statistics/Sandip Banerjee/New Central Book Agency Pvt. Ltd./97881-87134947 , Numerical Analysis And Computational Procedures/S A Mollah/New Central Book Agency Pvt. Ltd./97881-87134107 , An Introduction To Probability And Probability Distributions/Rajeshwar Singh/New Central Book Agency Pvt. Ltd./978938-4294175 , Dynamics Of Rigid Bodies/S A Mollah/New Central Book Agency Pvt. Ltd./978818-7134985 , Differential Geometry/M Majumdar/New Central Book Agency Pvt. Ltd./978938-4294144 , Advanced Higher Algebra/A N Das/New Central Book Agency Pvt. Ltd./978938-4294021 , Introduction To Abstract And Linear Algebra/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./97893-52550586 , Design Of Experiments And Sampling Methods/K C Bhuyan/New Central Book Agency Pvt. Ltd./97893-52550234 , Engineering Mathematics/T Veerarajan/Mcgraw Hill Education/ 97-0071328777 , Engineering Mathematics Ii/T Veerarajan/Mcgraw Hill Education/978-9387432345 , Advanced Engineering Mathematics/Ravish R. Singh/Mcgraw Hill Education/97-89353161033 , Discrete Mathematics/T Veerarajan/Mcgraw Hill Education/978-9353161606 , Business Mathematics And Statistics/N G Das, J. K. Das/Mcgraw Hill Education/978-0071333399 , A First Course In Mathematics For Management/M. Raghavachari/Mcgraw Hill Education/978-0070965706 , Fundamentals Of Mathematical Analysis/G. Das, S. Pattanayak/Mcgraw Hill Education/978-0074515730 , Introduction To Linear Algebra With Applications/James Defranza, Daniel Gagliardi/Mcgraw Hill Education/978-1259025587 , Numerical Methods With Programs In C/T Veerarajan, T Ramachandran/Mcgraw Hill Education/978-0070601611 , Ordinary And Partial Differential Equations With Laplace Transforms, Fourier Series And Applications/V. Sundarapandian/Khanna Publishers/978-1259004568 , Higher Engineering Mathematics/B.S. Grewal/Khanna Publishers/978-81-933284-9-1 , Discrete Mathematics And Its Applications/A. Tamilarasi And A.M. Natarajan/Khanna Publishers/978-81-7409-151-2 , Functions Of Complex Variables/A.K. Mukhopadhyay/Khanna Publishers/N/A , Numerical Methods In Engineering & Science With Programs In C, C++ & Matlab/B.S. Grewal/Khanna Publishers/978-81-7409-248-9 , An Introduction To The Calculus Of Variation For Engineers And Economics/A.K. Mukhopadhyay/Khanna Publishers/978-81-7409-186-4 , Engineering Mathematics/Mukul Bhatt/Mcgraw Hill Education India Pvt. Ltd/9789390000000 , Convective Heat And Mass Transfer/Adrian Bejan/John Wiley And Sons/978-0-470-90037-6 , Perspective In Environmental Studies/Anubha Kaushik And C P Kaushik/New Age International Publishers/978-93-86418-63-0 , Engineering Mechanics (Statics And Dynamics)/Dr D S Kumar/S K Karatia And Sons/978-93-5014-292-9 , Fundamentals Of Acoustics/Lawrence E. Kinsler, Austin R. Frey, Alan B. Coppens, James V. Sanders/Wiley/978-0-471-84789-2 , Foundations Of Engineering Acoustics/Frank Fahy/Academic Press/Elsevier/978-0122476655 , The Theory Of Sound, Volume I/Lord Rayleigh & Robert B. Lindsay/Dover Publications Inc./978-0486602929 , Mechanical Vibration/S.S. Rao/Pearson Education India/978-8177588743 , Vector Mechanics For Engineers: Statics And Dynamics/Beer, Johnston, Cornw Ell& Sanghi/Mcgraw Hill Education/978-1259062919 , Entrepreneurship Development And Small Business Enterprises/Charantimath Poornima M./Pearson/9353066263 , Entrepreneurial Development/Khanka S.S./S Chand/8121918014 , Mechanical Vibrations/Debabrata Nag/Wiley/978-8126530908 , Design Of Machine Elements/Dr.G.K.Vijayaraghav An&Dr.S.Vishnupriyan/Laxmi Publications/8192048535 , Introduction To Dynamics/Amitabha Ghosh/Springer/978-981-10-6094-6 , Mechanics Of Laminated Composite Plates And Shells – Theory And Analysis/J.N. Reddy/Crc Press/978-0203502808 , Composites: Science And Technology/Dr. R. C. Prasad, Dr. P. Ramakrishnan/New Age International (P) Ltd., Publishers/978-8122412512 , Product Design And Development/Karl Ulrich, Steven Eppinger And Maria C. Yang/Mc Graw Hill/978-1260043655 , Mechatronics: Integrated Mechanical Electronic Systems/K.P. Ramachandran, G.K. Vijayaraghavan, M.S.Balasundaram/Wiley India/978-8126518371 , Groovers Principles Of Modern Manufacturing Si Version/Mikell P. Groover/Wiley India/978-8126573059 , Manufacturing Science : Metal Cutting, Conventional And Non-Conventional Machine, Welding, Volume - Ii/G.S. Sawhney/Wiley India/97-89389520408 , Project Planning And Control With Pert And Cpm/Dr. B.C. Punmia, K.K. Khandelwal/Laxmi Publications (P) Ltd/978-8131806982 , Cad/Cam Theory And Practice/Ibrahim Zeid, R Sivasubramanian/Mcgraw Hill Education/978-0070151345 , Optimization For Engineering Design/Kalyanmoy Deb/Prentice Hall India Learning Private Limited/978-8120346789 , Mechanical Vibrations /G Kgrover/Nem Chand And Brothers /978-81-85240-56-5 , Tribology: Friction And Wear Of Engineering Materials /Ian Hutchings And Philip Shipway/Elsevier/978-0-08-100910-9 , Business Statistics: Text And Problems - With Introduction To Business Analytics/Nd Vohra/?Mcgraw Hill Education /978-9390727063 , Statistics For Management/Richard I. Levin, Masood H. Siddiqui, David S. Rubin, Sanjay Rastogi, /?Pearson Education/978-8184957495 , Financial Accounting/Sn Maheshwari, Suneel K Maheshwari,Sharad K Maheswari/?Vikas Publishing House/978-9352718535 , Management Accounting Principles & Practice/Shashi K. Gupta , R.K. Sharma, Neeti Gupta /Kalyani Publishers/N/A , Organizational Behaviour /Stephen P. Robbins, Timothy A. Judge , Neharika Vohra/?Pearson Education/978-9356064270 , Organisational Behaviour: Text, Cases & Games/K. Aswathappa/Himalaya Publishing House/978-93-5693-187-9 , Modern Microeconomics /A. Koustsoyiannis/?Palgrave Macmillan;/978-0333253496 , Business Law /Nd Kapoor /?Sultan Chand And Sons /978-9389174106 , Marketing Management /Phillip Kotler /?Pearson Education/978-9356062665 , Dominic Salvatore International Economics /Chandan Sharma /Wiley /978- 9354247170 , International Business /Charles W .L .Hill/?Mcgraw Hill/978-9355324771 , Strategic Management ( Concept & Cases )/Fred R David , Forest R David/Pearson Education/978-9332548930 , Production And Operations Management/Sn Chary/Mcgraw Hill/978-9353164812 , Production And Operations Management/E Anil Kumar , N Suresh/New Age International/978-8122421774 , E Commerce /Kenneth C. Laudon , Carol Guercio Traver/?Pearson Education/978-9356060647 , Entrepreneurship /Arya Kumar/Pearson Education /978-8131765784 , Corporate Finance /Ross , Westerfield ,Jaffe , Jordan /Mcgraw Hill /978-9390727926 , Security Analysis And Portfolio Management /Donald E. Fisher, Ronald J. Jordan, A.K . Pradhan /Pearson Education /978-9353066284 , Investment Analysis And Portfolio Management |/Prasanna Chandra /Mcgraw Hill /978-9354600074 , Advertising And Sales Promotion/Shh Kazmi, Satish Batra/Excel Books/978-8174466396 , Advertising And Sales Promotion ( An Integrated Marketing Communications Perspective)/George E Belch, , Michael A Belch, Keyoor Purani/Mcgraw Hill /978-9354600807 , Strategic Brand Management/Kevin Lane Keller , Vanitha Swaminathan, Ambi Mg Parameswaran , Issac C Jacob /Pearson Education /978-9353946135 , Human Resource Management: Text And Cases/ K. Aswathappa , Sadhna Dash/Mcgraw Hill /978-9355323675 , Managerial Economics And Business Strategy/Micheal R. Baye , Jeffery T . Prince/Mcgraw Hill/978-9354600203 , Intellectual Property Law/Avtar Singh/Eastern Book Company/978-9350289853 , Law Relating To Intellectual Property Rights/V K Ahuja/Lexis Nexis/978-8131251652 , Intellectual Property Rights Manual/Sumeet Malik/Eastern Book Company/978-9351452300 , Law Relating To Intellectual Property/Dr. B.L. Wadehra/Universal Law Publishing/978-9350350300 , Consumer Behavior/Kumar Leon G., Schiffman;Joe, Wisenblit;S. Ramesh/Pearson Education/978-9353069834 , Purchasing And Inventory Control/K S Menon And Sarita Kulkarni/ Shroff Publishers/978-8184047066 , Production Systems: Planning, Analysis, And Control/James L. Riggs /? John Wiley & Sons/? 978-0471847939 , A Textbook Ofmanufacturing Technology (Manufacturing Processes)/R K Rajput/ Laxmi Publications/? 978-8131802441 , A Textbook Of Material Science And Metallurgy /O P Khanna/Dhanpat Rai /978-8189928315 , Atomic Physics/Max Born (Author) , J. M. Radcliffe (Translated) R. J. B-. Stoyle (Translated)/Dover Publications/978-0486659848 , Concepts Of Atomic Physics/S P Kuila /New Central Book Agency (Ncba)/978-9352550838 , Fundamentals Of Molecular Spectroscopy/Banwell/Mcgraw Hill Education/978-9352601738 , Introduction To Nuclear And Particle Physics/V.K. Mittal, R.C. Verma, S.C. Gupta /Phi Learning/978-9387472617 , Concepts Ofnuclear Physics/Bernard Cohen/Mcgraw Hill Education/978-0070992498 , Nuclear And Particle Physics: An Introduction/B.R. Martin/Wiley/978-8126565078 , Introduction To Elementary Particle Physics/Alessandro Bettini/Cambridge University Press/978-1107050402 , Solid State Physics/Ashcroft, Mermin/Cengage Learning/978-8131500521 , Physics Of Semiconductor Devices/S.M. Sze, Kwok K. Ng /Wiley/978-8126517022 , Semiconductor Physics And Devices (Sie)/Donald Neamen (Author), Dhrubes Biswas/Mcgraw Hill Education/978-0071070102 , Liquid Crystal Sensors/Albert Schenning (Editor), Gregory P. Crawford (Editor), Dirk J. Broer (Editor)/Crc Press/978-1498729727 , Liquid Crystals: Experimental Study Of Physical Properties And Phase Transitions/Satyendra Kumar/Cambridge University Press/978-0521187947 , Liquid Crystals I/M.A. Athanassopoulou, M.A. Bates, Et Al./Springer/978-3662147160 , Dielectric Effect In The Isotropic Phase Of Liquid Crystal Materials/Mukherjee Prabir,Drozd-Rzoska Aleksandra,Rzoska Sylwester/Lambert Academic Publishing,/9783660000000 , Nanoscience With Liquid Crystals: From Self-Organized Nanostructures To Application/Quan Li/Springer/978-3319377124 , Fundamentals Of Mathematical Physics/A. B. Gupta/Books & Allied (P) Ltd/81-87134-23-2 , Higher Mathematical Physics/H. K. Das And Dr Rama Verma/S. Chand & Company Pvt. Ltd/978-93-83746-77-4 , Head Thermodynamics And Statistical Physics/Brij Lal, N. Subrahmanyam And P. S. Hemne/S. Chand & Company Pvt. Ltd/81-219-2813-3 , The Physics Of Solar Cells : Perovskites, Organics, And Photovoltaic Fundamentals/Juan Bisquert/Crc Press/9781138099968 , Nanomaterials And Nanocomposites: Synthesis, Properties, Characterization Techniques, And Applications/Rajendra Kumar Goyal/Crc Press/9781498761666 , Callisters Materials Science And Engineering./Balasubramaniam/Wiley India/9788126541607 , Introduction To Physics /Cutnell/Wiley India/9788126556021 , Physics, Vol 1, 5Ed , An Indian Adaptation /Halliday/Wiley India/9789354640384 , Physics, Vol 2, 5Ed, An Indian Adaptation /Halliday/Wiley India/9789354640438 , Principles Of Physics, 10Ed/Halliday/Wiley India/9788126552566 , Statistical Mechanics, 2Ed, An Indian Adaptation/Huang/Wiley India/9789354247736 , Classical Electrodynamics, An Indian Adaptation /Jackson/Wiley India/9789388991070 , Kittels Introduction To Solid State Physics, Wiley India Edition/Kittel/Wiley India/9788126578436 , Modern Physics, 4Ed, An Indian Adaptation /Krane/Wiley India/9789354244681 , Material Science: Nanotechnology And Applications /Kumar/Wiley India/9789390455317 , Introduction To Nanoscience And Nanotechnology, An Indian Adaptation /Poole/Wiley India/9789354240201 , Applied Solid State Physics/Rajnikant/Wiley India/9789354643309 , A Textbook Of Astronomy And Astrophysics /Sharma/Wiley India/9789389520903 , Tensors: Concepts And Applications With Scilab Programs/Soni /Wiley India/9789389633207 , Engineering Physics, As Per Aicte /Wiley Editorial Team/Wiley India/9788126521418 , A Textbook Of Applied Physics, Vol I/Jha/Wiley India/9789389307405 , A Textbook Of Applied Physics, Vol Ii/Jha/Wiley India/9789389520453 , Mathematical Methods In The Physical Sciences, 3Ed, An Indian Adaptation /Boas/Wiley India/9789354644252 , Fundamentals Of Fluid Mechanics/Sawhney/Wiley India/9789389698008 , Quantum Mechanics Concepts And Applications/Nouredine Zettili/Wiley India/978-0-470-02678-6 , Introductory Nuclear Physics/S. Krane Kenneth/Wiley India/978-8126517855 , Principles And Applications Of Ferroelectrics And Related Materials/M. E. Lines And A. M. Glass/Oxford University Press/978-0198507789 , A Modern Introduction To Quantum Field Theory/Michele Maggiore/Oxford University Press/978-0198520740 , The Physics Of Solids/J. B. Ketterson/Oxford University Press/978-0198742906 , Introduction To Spintronics/Supriyo Bandyopadhyay/Routledge/978-0367656447 , Perovskite Metal Oxide/Moharana/Elsevier/9780320000000 , Materials Characterization Techniques/Lin Li, Sam Zhang,Ashok Kumar/Crc Press/?978-1032064208 , Magnetic Measurement Techniques For Materials Characterization/Victorino Franco/Springer/978-3030704452 , Indentation Techniques In Ceramic Materials Characterization: Theory And Practice/Ahmad G.Solomah/Ceramics Transaction/978-1574982121 , Element Of X-Ray Diffraction/B D Cullity/Pearson Education India/9789332535169 , Introduction To Magnetic Materials/B D Cullity/Wiley-Ieee Press/978-0471477419 , Symmetry And Spectroscopy: An Introduction To Vibrational And Electronic Spectroscopy/Daniel C Harris/Dover Pubns/978-0486661445 , The Spectra And Structures Of Simple Free Radicals: Introduction To Molecular Spectroscopy/Gerhard Herzberg/Dover Pubns/978-0486658216 , An Introduction To Practical Infra-Red Spectroscopy/A D Cross/Dover Pubns/978-1489962744 , Handbook On The Physics And Chemistry Of Rare Earths: Optical Spectroscopy/Karl A.Gschneidner/North-Holland/978-0444521446 , Molecular Spectroscopy/Jackd.Graybeal/Mcgraw-Hill Education(Ise Edition)/978-0070243910 , Fundamentals Of Statistical And Thermal Physics/Frederick Reif/Sarat Book Distributors/9789380663142 , Thermodynamics And An Introduction To Thermostatistics/H. B. Callen/John Wiley & Sons Inc/9780471862567 , Introduction To Phase Transitions And Critical Phenomenon (International Series Of Monographs On Physics)/H. E. Stanley/Oxford University Press/9780195053166 , A Guide To Monte Carlo Simulations In Statistical Physics/David P. Landau And Kurt Binder/? Cambridge University Press;/9781139696463 , Statistical Mechanics/R. K. Pathria/Elsevier/9789351073970 , Computational Methods In Physics And Engineering/Samuel S M Wong/World Scientific/9810230435 , Mathematical Methods Of Physics/Jon Mathews And Robert L. Walker/?Pearson Addison-Wesley/805370021 , A Text Book Of Integrated Engineering Physics /Amal Chakraborty/Chhaya Prakashani Pvt Ltd/978-81-906486-1-5 , A Text Book Of Basic Engineering Physics/Amal Chakraborty/Chhaya Prakashani Pvt Ltd/978-8190648615
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 11
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Uttar Pradesh View Result →
34.
Educational and Research Institute #8825445 Technical Bid
Purchase , Particulars , Atomic Absorption Spectrophotometer ( Aas ) : Atomicabsorptionspectrophotometerwithgraphitetubeautomizer ( Gta ) , Flameautomizer ( Fa ) Andvapourgenerationassembly ( Vga ) , Unitforflame ( Airacetyleneandnitrousoxide-Acetylene ) , Chiller, Autosamplersforgtaandflame.: Technical Specification: Atomic Absorption Spectrophotometer: Computer Controlled With Built-Inflame Emission Mode, Wave Length Range: 180 – 910Nmwave Length, Sensitivity: Sensitivityatleast0.35Absfor5µg / Mlaqueouscopperstandardsolutionwithair – Acetylene Flame., Optics: Double Beamholographic Monochromator, Czerny Turner , Focallength: Atleast250mmfocallength, Resolution: 1800Lines / Mm, Slit Width: 0.1Nm, 0.2Nm, 0.4Nm, 1Nm, 2Nm & 5.0Nm ( Six Step Auto-Changer ) , Flame Atomizer: Alltitaniumor Equivalentburnerwithimpactbead / Flowspoiler, Premixdesign, Movement: Automatic Movementintothe Sample Compartment, Affect From Acids, Organic Solvent: Unaffected From Attacks By Acid Solution Or Organic Solvents ( E.G. Methylisobutylketone I.E. Mibk, Flame Alignment In Liquid Beam:Fullyautomatic, Optimizedwithmotorizedburnermountforverticalandhorizontalburneradjustment, Nebulizer:Highprecisionabletoprovidemanuallyadjustableuptakeratesmaterialofthenebulizerandrelatedventurishouldbeinerttoacidsolutionsandorganic Solventssuchasmibk, Flame Control: Computercontrolledignition, Gas Control: Computercontrolledwithoxidantandfuelgasesmonitoringtomonitorconstantfuel / Oxidantrationignition., Safety Function: Interlockingsystem To Preventignition, Essential Interlock Monitor: Burnertypeaswellasitspresenceinposition, Airselector, Flamesensor, Liquidtraplevel, Gassupplypressureandairsupplyanywhere Inthe Networkofgastubings Inthe System, Automatic Lamp Selection Function: Computer Controlled Hollow Cathode Lamp Selection And Alignment, Lamp Holder: Atleast8lampholderwithbuiltinpowersuppliesforhollowcathodelampsandelectrode–Lessdischargelampsorequivalent, Operating Parameter Setting: Automatic Setting, Read Out / Display: Displayfacilityforabsorbanceaswellasconcentration, Displayoferrorsorerrorcodes, Absorbancerangeat Least Upto 2.0 Abs., Scale Expansion: Scale Expansionatleastupto 100X, Integration Time: Integrationtime Shouldcoveratleast0.1To 60 Secondsrange, Measurement: Measurementsofmean, Rsdandcv, Backgroundonlymode, Integration Ofpeakheightandpeakareas.Accessories / Spares With Flame Aasystem, Vapor Generation Assembly: Shouldbecontinuousflowbasedhydride / Mercuryvaporgeneratorwithoptionofusingwithorwithoutaprogra, Mmable Auto Sampler Highly Automatic: After Pressing The Start Key, The Whole, Process ( Sampling, Reacting, Calibrating And Cleaning ) Will Be, Finished Automatically.High Sensitivity: The Sensitivity Of Most Elements Is Better Than 1Ng / Ml / 1%A. Sensitivity Of Arsenic Is Better Than 0.15Ng / Ml / 1%A.Rsd: Less Than 3% Measurement Time: The Single Measurement Will Take 25 To 35 Sec, Less Solution: Sample 2-2.5Ml ( Including Clean ) , Potassium, Borohydride 1-1.5Ml, Carrier Liquid 5-6Ml.Atomizer: Heated Absorption Cell ( Heated By Air-C2h2 Flame In Standard Carrier Gas: Ar Pressure: 0.32 Mpa, Consumption:70 Ml / Min, Power Requirements: 240 Vac, 50 / 60 Hz, Precision: Precisionofbetterthan Oratleast1%Atppblevelsofmercury, Arsenic Etc. Absorption Cell: Theabsorptioncell’Smaterialshouldhavenoeffectofthehighheatof The Flame Andthe Cellforthe Analysis Ofmercuryshouldbeofa Closedabsorptiondesign Flame Arrester: Flamearrestershouldbeprovidedinthetubewhichconnectsthe Assemblyto The Absorptioncell, Cell Design Holder: Thedesignofthecellholdershouldgiveafirmandeasilyadjustable ( Foralignment ) Mountingonthe Burnerhead. System Accessories: Complete Withnecessary Reagentbottles, Connectorsetc.Hollow Cathode Lamps: Arsenic, Antimony, Calcium, Chromium, Cobalt, Copper, Iron, Nickel, Lead, Manganese, Mercury, Tin, Zinc, Molybdenum. Air Compressor With Air Filter Or Equivalent Air Service Unit:Completewithpressureregulatorquiteinoperation, Necessarytubingandconnectorsandshouldmeettheairsupplyrequirements Of Aasoperation.Oil Free Pump: Oil- Free Pumpandmoisture Trap, Corrosion Resistant: Resistanttoacidic Vapourandthedrainvalve ( If Any ) Shouldbemade Of Stainlesssteelof Equivalentcorrosionresistantmaterial Nitrous – Oxide Gas Regulator: Nitrousoxidegasregulator ( Twostage ) Withheater, Withnecessarytubing’Sandconnectors.Necessarytransformershouldbeprovidedto Transformthissupplyto Therequirementsoftheheater.Theheatershouldworkon230±10Volts50hzacpowersupply.Acetylene Gas Regulator: Acetylene Gasregulator ( Twostage ) Withnecessarytubingandconnectors.Nitrogen Gas Regulator: Nitrogenregulator ( Twostage ) Withnecessarytuningsandconnectors.Graphite Furnace System, Graphite Tubeatomizer: Should Becomputercontrolledfullyenclosedgraphitetubesystemconsistingofstabilizedtemperature / Totalpyrolyticgraphite Plateform.Gassupplies: Provisionoftwogassupplies ( Programmeselectable ) Withindependentcontroloverthe Gassupplythroughthe Furnace.Heatingrate: Heatingrate Ofatleast2500°Cpersecond Coolingtime: Coolingtime20seconds Temperature Range: Temperaturerangeambientto 3800°Cor Morein 1°Cincrementsfeedbacksystem: Feedbacksystemforfurnacetemperaturecontrol, Interlocksforwater, Gas, Temperature, Furnacedoor, Graphitetubedamage Andmainspower.Temp.Programming Upto 20 Rdertemperatureprogrammingfacilitywithflexibilityofprogramselection, Ramptime, Gases, Gasflowandreadtriggerforeachtemperature Step.Control Computercontrolledwithappropriateprovisionforprintoutofthe Furnace Andsample Parameters Display Calibrationdata / Graphs, Temperatureprofiles, Signalgraphicsandthe Instrumentstatus. Memory Memoryshouldbe Ableto Storeatleasttwenty Fivenonvolatileprogrammes Chiller Cooling Mode: Compressor Cooling, Temperature Controller: Pid Controller, Temperature Range: 5°C – 35°C, Accuracy: ±1°C, Cooling Capacity: 1300W @25°C, Pump Pressure: =1.3Bar, Pump Flow: =15Litre / Min, Tank Volume: 8 Litre, Tank Material: Stainless Steel Ss304, Refrigerant: R134a Size ( W*D*H ) : 360*450*653Mm, Power Supply: Ac220v, 50 / 60Hz Dataworkstation Application Softwareprogram Facility With Multitasking Software Shouldprovidecompletecontrolofinstrumentwithinstrumentstatusdisplayanditsvariousaccessories. Provide Accurate And Reproducible Time Averaged, Integration, Non – Averaged Integration, Multi Level Calibration. Softwareshouldhandleinstrumentlinearabsorbancereading, Concentration, Oremissionintensity, Integrationtime, Built-Instatistics, Calibrationequationcontrol, Slopeofanalyticalcurveusingoperatorselectivecalibrationstandard Built-Ininterfaceforcomputerconnectionanduseofoptionalaccessories. Comprehensivequalitycontrolprotocolsfacilityincludingblank, Multiplequalitycontrolstandards, Qa / Qcaudittrailandcalibrationfailure. Computer System, Make Reputed Brand, Processor I5 -10Th Gen, Ram 8Gb Or Advance.Ssd 512, Monitor 19”Led, Operation Software: Preloaded Windows Xp Professional Operating System With Licensed Cd Or Better Msoffice2000standardwithmedia, Manualandlicensedcdor Better, Preloaded Antivirus With Latest Version Along With Licensed Cd Or Better Fume Hoodexhaust Fume Hood Made In Stainless Steel Chimney With Std 20Ft Ss304 Powder Coated Exhaust Pipe With Inert Centrifugal Blower 1400Rpm, Ac 230V, With Standard Fitting Installation Hardware For Installation. Operation Kit Standardoperationkitincludingallrequireditems, Tubings, Fittingsforstartup / Regularoperationofinstrumentsuchasgaspurificationsystem To Be Supplied With The System. Operation / Maintenance Manual Operation / Maintenance Manualforeachunit Analytical Manual Analyticalmanualincludingapplicationsforflame, Vgaandgraphite System Operation And Maintenance Training One Weektrainingto Beprovidedtotwo Scientiston Softwaretraining, Operation, Maintenance Andtrouble Shootingaspectsof Instrumentatthe Timeof Installation. , Air Conditioner : Split Ac With Inverter Swing Compressor: Streamer Discharge & Dew Clean Technology For Healthy Air Capacity 1.5 Ton: Suitable For Medium Sized Rooms ( 111 To 150 Sq.Ft ) 5 Star: Best In Class Efficiency Copper Condenser Coil: Better Cooling And Requires Low Maintenance Key Features- Cooling Capacity @ 43°C: 100%; Noise Level: 38 Db ( A ) ; Ambient Operation: 54°C Special Features: 15% Higher Iseer Compared To Base Iseer ( 4.5 ) Of 5 Star Ac; Patented Streamer Discharge For Healthy Air; Intelligent Eye To Adjust Cooling According To Human Presence; Triple Display ( Power Consumption %Age, Set / Room Temperature & Auto Error Code ) ; Dew Clean Technology That Cleans Indoor Unit Coil With A Press Of Button Refrigerant Gas: R32 Environmental Friendly - No Ozone Depletion Potential Indoor Unit, Outdoor Unit, Remote Control, User Manual, Warranty Card & Standard Installation Kit , Bod Incubator: Floor-Standing, Double Doors .Temperature Range 5°C To 80°C With Uniformity Of ±0.2°C @ 10°C. Microprocessor Pid Controller Delivers Superior Temperature Control Accuracy, Required For Precise Results. Features And Advantages Include Illumination Lamp, Caster Wheels For Easy Mobility, Digital Timer . 175Litres / 6.1Cft, External Chamber Ms, Internal Chamber Ss304, Solid Insulated Door ( With Glass & Without Glass ) W / Lock Door, Stainless Steel 5 Shelves Removable, Caster Wheels, Humidity System, Light System By Interior Illumination W / 3 Fluorescent Tubes, Timer 0-99 Hours For Regulating Cycles Illumination Condition, Rfid Enabled Door Locking System. Brand Name And Model Name Must Come In The Display. , Centrifuge: Max Speed: 15000 Rpm Speed Accuracy : ±1Rpm Or ±1 X G Temperature: -10°C To +40°C. Possibility Of Precooling During Standstill Rotor Type: Angle Rotor For Conical Centrifuge Tubes. All Rotors With Lid And Anti-Corrosion Coating Rotor Capacity: 8 X 50 Ml With Max. Rpm:~14000 Rpm 8 X 15Ml With Max. Rpm:~ 14, 000 Pre Selection Of Run Parameters In Terms Of Rpm Timer Range: Pre Selection Of Time From 30Sec. To 10 Hr. Or Continuous Set Time In Hrs:Min, Min:Sec, Or Continuous Mode Automatic Rotor Identification & Imbalance Sensor Low Vibration During The Operation. Extremely Low Noise During Operation ( <66 Db ) . With Microcontroller For Speed, Time And Temperature Motorized Lid Lock And Inter Lock Keys For Start, Stop And Lid Open Power Supply: 230 V / 50-60 Hz , Chns Analyser : Fully Automated Pc Controlled Elemental Analyser For Solid And Liquid Samples.The Analyzer Must Be Able To Simultaneously Determine The Elements In The Following Combinations: Chns, Or Chn, Or Cns, Or Cn, Or Nwithout A Need To Change Column Helium As Carrier Gas And Option For Argon As Carrier Gas In Chns Mode.Sample Weight Range: 0.2 Mg Of Organic Compound To 800 Mg Or More Inhomogeneous Soildetection Range: 0 To 100% For All Elements ( C, H, N, S ) With The Capability Of Measuringat Least 10 Mg Absolute Carbon In Chns Mode And More Than 50 Mg In Cn Mode Standard Deviation: ?0.1% Of Absolute. Lower Detection Limit Of < 50 Ppm For N , C And S With Thermal Conductivity Detector ( Tcd ) Dependingon Sample Weight. The Instrument Must Fulfil The International And National Safety Standards. For Safety Reasons, Theentire Instrument Including Furnaces Must Internally Operate On Low Voltage ( < 50 V ) . Large Dynamic Measurement, Range From 0.1 Milligram, Chemical Substance To1 Gram Inhomogeneous Soil, Best Analysis Results For Any Sample Matrix, Wide Variety Of Optional Configurations, Individually Extendible, Low And Tool-Free Maintenance, Low Noise Level, Low Total Cost Of Ownership, Integrated 120 Position Auto Sampler As Standard, Patented Ball Valve Forblank-Free Sample Transfer. Furnace System • Should Have Two Zone Furnace System, Separate For Combustion And Reduction With Independent Temperature Control For Each Furnace In Chns Mode. Easy Slide-Out Mechanism Of Furnace For Routine Maintenance Work. It Should Be Possible To Set Difference Temperature For Combustion And Reduction. • Controlled Furnace Temperature Should Be 1200 Deg C Or More. • Easy Ash Removal Without Change Of Combustion Tube By Means Of An Exchangeable Ash Crucible. Separation System • Combustion Gases In The Form Co2, H2o, N2 And So2 Are Separated By Means Of Single Temperature Programmed Desorption ( Tpd ) Column. Detector System • Oxygen Intrusion Free Thermistor Technology-Based Temperature Stabilized Tcd Detector For Measurement Of C-H-N-S-O Auto Sampler System • Integrated 50 Or More Position Automatic Sampler Having Capacity To Handle Upto 1000 Mg Sample In Each Sampler Holder Position Of Carousel Software • Should Be Windows Based And Should Have Operating Software With Automatic Calculation And Statistical Evaluation Of Sample Results, Automatic Leak Check, Sleep / Wakeup Function, Gas Stop, Service And Maintenance Support And Weight Transfer From External Balance. • All Instrument Functions Incl. Gas Flow And Pressures Must Be Digitally Controlled For Diagnosis And Trouble Shooting Via The Internet. Consumables: To Be Supplied With Consumables Enough For 1, 000 Sample Analysis In Chns / Cns Mode. Necessary Documents: - • Catalogue In Original. • All Technical Specifications Should Be Printed On The Manufacturers Catalogue / Data Sheet. , Compound Microscope : Compound Microscope ( 10X Eye Piece, Objective With Magnifying Powers 10X, 40X And 100X Oil Immersion Objective Lens ( Body - Monocular Die-Cast Body, Inclinable Upto A Horizontal Position ( 90° ) ; Focussing - By Coarse & Fine Focusing Knobs; Eyepieces - Huygenian 10X And 15X; Objectives - Hard Anti-Reflection Coated, Colour Coded Par Focal Achromatic 10X, 40X, 100X, Oil Immersion; Condenser - Built-In Sub Stage Condenser With Iris Diaphragm. Branded, Best Quality ) , Compoundtrinocular Microscope With Camera: Trinocular Head, Eyepiece: Swf 10X, U Plan Objectives Of 4X, 10X, 40X And 100X, Abbe 1.25 N. A. Condenser With Iris Diaphragm, Ceramic Coated Flat Top Stage, Co Axial Coarse And Fine Focusing, Led Or Halogen Illumination With Automatic Voltage Sending Power Supply, Digital Camera ( 5 Mega Pixels ) , Fire Wire Cable, C-Mount Adapter 0.7X And Image Analysis Software With 4D Experiment Ability. , Conductivity Bridge : Advanced Microprocessor Based Design. Brand Name And Model Name Must Come In The Display. Conductivity And Tds Modes. Automatic And Manual Temperature Compensation Auto Ranging. 0-20?S / Cm, 20-200?S / Cm, 200-2000?S / Cm, 2 – 20 Ms / Cm, 20-200 Ms / Cm, 200Ms / Cm -2000. Multi Point Calibration. Tds Conversion Factor From 0.40 To 1.00 Cell Constant Adjustable From 0.1 To 10.0 Temperature Coefficient Adjustable From 0 To 10% / °C Normalisation Temperature Adjustable From 15 To 30 °C. Bi Directional Rs232 Interface. Baud Rate Selectable From 1200, 2400, 4800 And9600. Single And Continuous Print Out Of Conductivity. Multiple Printout Types. Combinations Selectable From Sr. No., Cond / Tds, Date, Time And Temperature. Real Time Clock. Temperature Setting ( Manual Temperature Compensation ) . Calibration Report As Per Glp Requirements Lcd Touch Screen Display With Backlight. Memory Storage Of 100 Measurements. Data Logging Facility Up To 500 Results. Data Logging Interval Selectable From 5S, 10S, 20S, 30S, 1M, 2M And 5M. Temperature Calibration. , Compound Phase Contrast Binocular Microscope : Body: Binocular, Sturdy, Stable Base Body With Focus Adjustment Controls. Eye Piece: Paired, High Quality, Achromatic, Wide Field, System Complete With Illumination System Is Required. Objective: Three Objectives 10X, 40X, 100X. 10X And 40X Objectives Should Have Numerical Apertures Of 0.25 And 0.65 Respectively.100X Should Have Numerical Aperture Of 1.65. Nose Piece: Revolving Nose Piece To Accommodate A Minimum Of Three Objectives With Click Stops. It Should Be Provided With Ribbed Grip For Easy Rotation Mounted On A Precision Ball Bearing Mechanism For Smooth And Accurate Alignment. Stage Uniformly Horizontal, Mechanical Stage Having Dimensions Of Length 140 Mm ( + / - 20Mm ) . The Stage Should Be Provided With Spring Loaded Slide Holder For Exact Positioning Of Specimen / Slide. The Stage Should Have Ball-Bearing Arrangement To Allow Smooth Travel In Transverse Directions I.E. 80 Mm ( + / -10Mm ) And Front To Back Direction, 50Mm ( + / - 10Mm ) . The System Should Have A Build-In Variable Light Source ( Illuminator ) . This Light Sourceshould Have A 50 W, 12 V Halogen Lamp. All Consumables Required For Installation And Standardization Of System And Microscopecover To Be Given Free Of Cost. , Desktop Computer With Accessories : Corei5-11400 Motherboard-Gigabyte H510mh , 16 Gb Ddr4 Ram, 512 Ssd, Key Board, Mouse, 19”Led Colour Monitor, Bluetooth, Cabinet, Branded Laser Printer. , Digestion Hood For The Laboratory : Internal Lining: Suitable Material For Hf Resistancelike Upvc Or Pp Internal Size ( 1600X675x1250 Mm : Wxdxh ) ± 10%Should Supply With Digital Face Velocity Meter Withalarm / Low Exhaust Indicatorcold Water Service Fixture ( Inlet And Outlet, Pre-Plumbed ) For Using Distillationunit Inside. Tri-Wall Construction For Maximum Robustness. U-Pvc / Pp Internal Chamber. Chain And Sprocket Sash Support System. Hood Lighting Is Pre-Wired. Lighting Is Electronically Ballasted, Energy Efficient, Instant Start. Typical Light Intensity On Work Surface Is >1076 Lux In Zero Ambient Conditions. U-Pvc Exhaust Collar Ensures Superior Chemical Resistance. One Gas Service Fixture-Pre-Plumbed Internal Electrical Connection: Two Number ( 5 / 15 Amp ) Socket Internal Light Fitting For Proper Illumination With External Switches Vertical Sash: Polycarbonate / Toughened Float Glass ( Acidresistant ) Removable Baffle / Suitable Mechanism For Easycleaning, Blower And Duct: Pp+Frp – 250 Mm Diameter Duct 20 Feet In Length 1 Hp Motor And Reputed And Standard Company ( Brand Must Be Mentioned ) , 600 Cfm Minimum Volume Weather Proof Pp / Motor Housing. Exhaust: Pp+Frp Exhaust Fan With Chemical Resistantimpeller System Will Be Installed In First Floor Of Laboratory Block. Stack Height Should Beat Least Three Meters Above Top Roof ( Two Storey Building ) Shaping Vanes Increase Airflow “Sweep” At The Critical Area Atthe Sidewall To Improve Containment, Especially When Laboratorypersonnel Walk Fast In Front Of The Hood. , Electronic Precession Balance : Maximum Capacity [ Max ] 200 / 2000 G Minimum Load 20 Mg, Readability [ D ] , 0.001 / 0.01 G Tare Range-2000 G, Repeatability ( Max ) 0.001 / 0.01 G Repeatability ( 5% Max ) 0.0005 / 0.005 G, Linearity±0.002 / 0.02 G Stabilization Time2 / 1.5 S Adjustment External Physical Parameters Levelling System Manual Display Lcd ( Backlit ) Delivery Components Balance, Weighing Pan, Weighing Pan Shield, Grounding Foot ×1, Foot ×3, Power Supply. Weighing Pan Dimensions 128×128 Mm Packaging Dimensions 470×380×336 Mm Net Weight-3.2 Kg Gross Weight 4.8 Kg, Protection Class Ip 43 , Communication Interface Communication Interface, 2×Rs232¹, Usb-A, Usb-B, Wi-Fi® ( Option ) Electrical Parameters, Power Supply , Adapter: 100-240V Ac 50 / 60Hz 0.6A; 12V Dc 1.2A Balance: 12 – 15V Dc 0.4A Max , Environmental Conditions Operating Temperature +10 — +40 °C. , Environmental Shaker :Environment Shaking Incubator : Salient Features , Programmable Logic Controller ( Plc ) , 4.3 Hmi With Colour Display And Touch Screen, Password Protected Operation. , Universal Platform To Accommodate Vanous Type Of Flask And Test Tube Rack Max ( 8X250ml ) .Electronic Capacitance Type Humidity Sensor , Direct Display Of Temperature And Humidity, Display Of Set Value And Process Value, Unique Air Flow System Ensures Even Distribution Of Temperature And Humidity, Precise Control Of Temperature And Humidity By Using Built In Pid Controller ( Auto Tuning Type ) , Forward And Backward Rotation Programs And Rpm 30-350, Maintenance Free Brushless Induction Motor, Variable Frequency Drive ( Vfd ) Permanently Lubricated Bearing For Noise Less Operation, Triple Eccentric Counter Balanced Drive Mechanism For Uniform Agitation, Castor Wheel For Ease Of Mobility Adjustable Levelling Jack. , Horizontal Autoclave : 1.Fully Automatic Micro Processor Based High Pressure, High Vacuum Autoclave For Sterilizing Material Including Agars, Sterilization Of Solution In Open & Closed Bottles, Disinfection Of Materials And Waste Decontamination. 2. Should Be Front Loading, Have Rectangular, Horizontal Chamber With Well Insulated Jacket, Chamber Volume Minimum 165 Lit. 3. Should Have Single Vertical Sliding Door To Have A Pass Through System. Door Should Be Electrically Controlled Having Fully Automatic Function With Multiple Safety Arrangements. Sealing System Should Be Based On Silicone Seal.4. Should Have At Least 50Mm Thick Insulation Materials On Jacket And In Doors To Ensure Low Thermal Losses. Working Temp. Of The Door Should Be Less Than 45Deg. C. 5. Should Be High Grade Stainless Steel.6. Should Have A Built In Colousr Touch Screen.7. Should Have Audio Visual Alarms In Case Of Undesired Situations. 8. Should Have Programmable Operators Access Level. 9. Should Have At Least 10 Pre Programmed Standard Cycles Plus 5 Or More User Programmable Cycles And Provision Of Chip Card Port For Loading Of New Programs Through Chip Cards.10. Should Have Temperature Adjustable From 25Deg. To 135 Deg. C. 11. Safe Working Pressure Range Should Be Adjustable 12. Should Have Complete Monitoring Of Cycle Operation And Provided With At Least Two Pressuresensors And Two Temp. Sensors ( Pt -100 ) In Addition To Analog For Chamber Pressure, Jacket Pressure And Steam Generator Pressure Indication.13. The Unit Should Be Equipped With Multiple Safety Mechanisms For Emergency Stop Over Pressure Safety Valves For Chamber And Jacket, Over Temp Safety, Steam Traps And Electrical Safety.14. The Unit Should Include Non Fade Built In Thermo-Recorder For Step Progress Values During The Cycle With Time And Date And Alarm Condition If Any.15. Should Have Built In Feature Of Water Saving System For Water Conservation.16. Should Be Supplied Complete With High Quality Stainless Steel Trolleys And Sterilization Baskets: A. External Trolley = 01 Nos.B. Internal Trolley With Steel Roller C. Shelves = 01 Nos. And D. 2 Sets Of Sterilization Baskets. 17. All Accessories & Electric Fitting To Be Included 18. Three Compulsory Visits For Calibration And Check-Up Irrespective Of Complaints In Year.19. The Steam Generator Should Be Also Be Made Of Aisi 316 Ti Steel & The Steam Generator Should Be Equipped With Automatic Cleaning Facility. 20. Integrated Waste Water Cooling, Integrated Water Saving Device. Touch Screen Display, Chip Card Reader And Rs 232 Interface. , Hot Air Oven : Capacity 250 Litre, Temp Range: +5ºc To 250ºc. Control Accuracy: ±0.2ºc, Uniformity: ± 2.0 At 100.0ºc Minimum 3 No. Of Shelves With Height Adjustable In 25Mm Steps, Glass Window In-Built Into The Door For Easy Viewing Of Samples, Automatic Cut Off Of Heater & Blower When Door Opened, Digital Pid Temperature Controller With Timer, Alarms And Auto Tuning, Aero Dynamic Internal Design For Achieving Horizontal Air Circulation, Solid And Plain Bottom Without Electrical, Outer Body Made Of G.I Epoxy Coated Inner Body Made Of Stainless Steel With Clear Bottom Ce Certified. Brand Name And Model Name Must Come In The Display. , Hot Plate : Size 420 X 320 X 130 Mm Ht. ( Total Height With Feet ) Weight 9 Kg, Voltage 230V ( 50Hz ) , Temperature 250°C Maximum Uniformity + / - 2°C.Temperature Rise 6°C Per Minute Temperature Drop 1°C Per Minute, The Hot Plate Should Be Able To Control The Temperature Within + / - 2°C, Temperature Should Be Uniform Throughout The Hot Plate Surface. 6. There Should Be Rims Around The Edges Of The Hot Plate For Safety, Power 2200 W, Approx. 9.6 Amp In 230V, Material Pfa Coated Graphite. , Laminar Air Flow Chamber : Microprocessor Controlled System With Motorised Door. Type Of Airflow: Horizontal Full Password Protected Operation. 70% Of Air Should Be Recirculated To The Cabinet Work Area Through Hepa Filter And The 30% Balance Should Be Exhausted Through Hepa. The Balance Should Be Dynamic To Ensure The 70 / 30 Recirculation / Exhaust Air The Instrument Must Have Hepa Filters On Down Flow As Well As Exhaust With An Efficacy Of 99.99% For Particles Sized Of Calibration Certificates Along With Dop Test Report Shall Have To Be Submitted At The Time Of Supply Of Instrument ) The Dimensions Of The Working Chamber Should Be In The Following Range: Length: 90-120 Cm , Width: 40-60 Cm , Height: 50-80 Cm . The Main Body And Working Chamber Of The Cabinet Should Be Made Of Stainless Steel, Rigid And Rustproof With Removable Trays The Cabinet Should Have An Electrically Operated Sliding Front Sash Made Of Safety ( Uv ) Glass With A Provision For Manual Operation Of The Sliding Front Window. Also, The Sliding Front Sash Should Have True Air And Aerosol Tight Electrical Shahs. Front Door: Clear Transparent Sturdy Material Work Chamber Should Be Fitted With A Fluorescent Lamp For Illumination And Should Have Programmable Uv Light Cycle. The Unit Should Have Microprocessor Control Keys With Large Icons And A Large Graphical Display With Provision For The Permanent Display Of The Following Key Cabinet Conditions. I. Inflow And Down Flow Air Velocity Ii. Exhaust And Recirculated Airflow Volumes Iii. Time And Date Iv. Residual Lifetime Of Filters & Total Time Of Cabinet Operation ( Optional ) Alarm Notification In The Following Situations: I. Low Inflow Velocity Ii. Low Down Flow Air Velocity Iii. Hepa Filter Life Iv. Alarms For Clogged Filters V. Other Malfunction Compatible At A Power Supply Of 220 V, 50Hz Noise Level: < 65 Db Basic Cabinet Should Be Termite And Insect Resistant And Washable Accessories: Manometer, Gas Inlet, Castors The Cabinet Should Be With A Stand With Lockable Castors Brand Name And Model Name Must Come In The Display. , Multimeter With Ion Selective Electrodes For Water Quality Testing : Colour Capacitive Touch Screen With Software Control Facility. Can Store 2000 Sets Of Test Data, Which Can Be Saved And Transferred To Usb Memory Stick And Opened With Excel. Power: Universal Ac Adapter And With Rechargeable Lithium Battery ( Included ) . Concentration Range: ( 0~19990 ) , Can Switch 6 Kind Of Concentration Units: Ug / L, Mg / L, G / L, Mol / L, Mmol / L, Ppm. Concentration Resolution: 4 Significant Digits ( Expressed In Scientific Notation ) Can Be Operated Through 5 Amp Plug And Battery. Accuracy: ±0.1Mv Or 0.03% Temp Range: ( 0? To 100? ) Accuracy: ±0.1? Output Through Usb / Bluetooth Battery Life 1000 Hour. Type: Lithium Battery. Ise- Fluoride, Chloride , Bromide, Ammonia, Brand Name And Model Name Must Come In The Display. , Mechanical Shaker: Compact Bench Top Microcontroller Based Shaker With Temperature Control Range From Ambient +5°C To 60°C , Ergonomicallydesignedwithminimalfootprint Triple-Eccentriccounterbalanceddriveforuniformagitationwith 25Mmshakingorbitmaintenance Freepermanent ( Self ) Lubricatedshieldballbearingsfornoiselessoperationfrpexteriorwithanti-Vibrationmountforsmoothrunning Preciseshaking Speedcontrolwithgentlestart / Stopcycle, Preventingspillagepowerfulpermanentmagnetdcdrivewithdigitalleddisplayofspeed Pulsewidthmodulation ( Pwm ) Basedspeedcontroloptionaltimerfunctionforspeed Autore-Starttosetspeedafterpoweroutage Universalplatformtoaccommodateerlenmeyer, Roundbottom, Volumetricflasks, Testtube Holders&Microplateholders Hasautorestartfunctionafterpowerinterruptionwithnonvolatilememory ( Retainsetparametersafterpowerfailure ) Orbital Shaking With Orbit Diameter Of 25 Mm, Speed 20-450 Rpm With Accuracy Of ± 2 Rpm, Led Display , Universal Platform And Clamps To Hold Flaskscapacity 100Ml-64Nos Or 1000Ml. -16Nos, Tray Dimension : 450 X 450 Mm, Noiseless Operation, Operational Voltage - 220 ± 20V, 50 Hz, Should Meet Ce Standards , Mechanical Soil Auger : Soil Auger Sampler : Made Of Iron : Screw Type, One Meter Long With Handle :Size : 2.5 Cm. Dia , Microprocessor Based Flame Photometer : Alphanumeric Graphics Lcd ( 240X 128 Dots ) Brand Name And Model Name Must Come In The Display Microcontroller Based Na, K, Li, Ca& Ba Auto Ignition Gas Leak Sensor Auto Gas Cut Off. Pass Word Protection. Separate Logging For Guest And Administrator Quadratic Curve Fitting Rtc High Quality Compressor Software Na Minimum Concentration Without Dilution 2 Ppm And 0 -200 Meq / L With 1:100 Dilution Ba Can Be Measured Upto 3000Ppm Without Dilution In Higher Concentration Mode And 500Ppm At Lower Concentration Mode. Caupto 250 Meq / L With 1;100 Dilution Bandwidth 10Nm Curve Fitting Accuracy ±2% F.S Pc Link Software To Send Data To Pc. Gas Cylinder And Regulator Must Be Supplied. Product Must Be Ce Certified And Company Should Bear Iso Certification. Brand Name And Model Name Must Come In The Display. , Microtomy : Section Thickness Range: 0.25 - 60 ?M Trimming Thickness Range: 5 - 500 ?M Resolution: 0.25 For 0.25 - 1 ?M 0.5 For 1 - 5 ?M 1 For 5 - 20 ?M 2 For 20 - 30 ?M 5 For 30 - 60 ?M Resolution: 5 For 5 - 10 ?M 10 For 10 - 100 ?M 20 For 100- 200 ?M 50 For 200 - 500 ?M Knife Carrier Retraction During Return Travel Of The Specimen: 60 ?M Horizontal Feed Range Of The Knife Carrier: Max. 28Mm Vertical Specimen Stoke: Max. 64Mm Specimen Size: 55 X 50 Mm Specimen Orientation: X And Y Axes: Universal 8º Z Axis: Up To 360º , Microwave Digestion System : Large Furnace Cavity Design With Completely Independent Intellectualproperty Rights, 1~6 100Ml Ultra-High Pressure Digestion Tanks Can Be Placed At The Same Time; Industrial Grade 1000W Magnetron. Temperature And Pressure Dual Measurement And Control, Precise Control, Active Prevention Of Over-Temperature And Over-Pressure, Maximum Working Pressure: 6Mpa, Maximum Withstand Temperature: 300°C, Maximum Working Temperature: 250°C High-Precision Anti-Interference Pressure Sensor Adopts Double Explosion- Proof Control Mode To Directly Measure The Actual Reaction Pressure In The Digestion Tank, The Pressure Measurement Range Is 0~10Mpa, And The Pressure Measurement Accuracy Is 0.01Mpa; Insert High-Sensitivity Platinum Resistance Temperature Sensor, Directlymeasure The Actual Reaction Temperature In The Digestion Tank, The Temperature Range Is 0~300°C, And The Temperature Measurement Accuracy Is ±0.1°C; It Can Measure And Control The Pressure And Temperature In Any Reactiontank, And The 7-Inch High-Definition Camera Display Accurately Shows The Chemical Reaction Process; Equipped With Perfluorination Digestion Tank Or Ft Double-Layer Digestion Tank: Ptfe Digestion Tank Is Made Of Ptfe ( Polytetrafluoroethylene ) , And The Sheath Is Made Of High-Strength Explosion-Proof Aerospace Composite. The Fiber Material Is Made By One-Time Die-Casting, High Temperature Resistance, High Pressure And Strong Acid Corrosion Resistance; Easy Disassembly And Assembly, Fast Cooling; Double Venting Protection And Digestion Tank For Venting Holes And Sealed Bowls; Up To 6 Ultra-High Pressure Digestion Tanks Can Be Placed At The Same Time; The Furnace Cavity Is Ventilated With Acid Resistance, Large Air Volume Centrifugal Fan, And The Exhaust Air Volume Is 5M3 / Min; Specially Designed Self-Locking Ground Moving Safety Door To Resist Accidental Explosion And Microwave Leakage. Tank Technical Parameters: The Pressure-Resistant Jacket Material Is A Hydrophobic High-Strength Pressure-Resistant Composite Fiber Material, Which Is Explosion-Proof And Supports Washing And Easy To Clean. The Inner Tank Adopts Imported Modified Polytetrafluoroethylene ( Tfm ) , High-Strength Frame Type Closed Ultra-High Pressure Reaction Tank: The Highest Withstand Temperature =300 °C. Explosion-Proof Membrane Automatic Pressure Relief And Peek Compressionmodule Pressure Relief Safety Design To Ensure The Safe Operation Of The Instrument. The Whole Tank Pressure Monitoring System, The Threshold Value Can Beadjusted. Using High-Strength Engineering Plastics For One Injection Molding, Independent Ultra-High Pressure Digestion Tank Holder. Tank-6Pcs, Power- Ac220v / 50Hz / 10A, Microwave Frequency-2450 ( Mhz ) , Microwave Output Power-1000 ( W ) , Microwave Cavity-45 ( L ) , Protective Spraying- Pfa, Control Heating Method- Pid, Temperature Ramp-1~50? / Min, Cooling Time-=25Min, Microwave Leakage-=0.3Mw / Cm2, Temperature Control Range-0~300?, Temperature Control Accuracy-0.1?, Pressure Control Range-0~10Mpa, Pressure Accuracy-0.01Mpa, Outer Tank Material- Peek, Inner Can Material- Tfm1700, Highest Temperature Resistance-300?, Operating Temperature-250?, Highest Pressure-15Mpa , Microwave Oven : Convection Microwave Oven With Ceramic Enamel Cavity 21L ( 1. Capacity: 0.7 Cu.Ft. / 21 Ltr., 2. Heat Source: Convection 3. Power: Power Consumption ( Microwave ) 4.1200W 5. Power Source: 230V / 50Hz 6. Output Power ( Max ) : 2350W 7. Powerlevel:6 8. Display Type: Led Bar 9. Control Method: Membrane 10. Door Opening Type: Handle 11. Microwave Distribution: Turntable 12. Cavity Interior :Ceramic Enamel ) , Millipore Water Purifier : Parameter Value Or Range Pressure 2 – 6 Bar Flow Rate > 10 L / Min At 2 Bar Feed Water Type Potable Water Temperature 5 – 35 °C Conductivity 10 – 2000 ?S / Cm At 25 °C Ph 4 – 10 Hardness ( As Caco3 ) < 300 Ppm Silica Concentration <30 Ppm Carbon Dioxide Concentration ( Co2 ) < 30 Ppm Langelier Saturation Index ( Lsi ) < 0.3 Fouling Index ( Fi5 ) Or Silt Density Index ( Sdi ) = 7 ( * ) Total Organic Carbon ( Toc ) < 1 Ppm Free Chlorine < 1.5 Ppm Typical Water Quality Measures With A Well-Designed And Maintained Distribution Loop Of 20 Meters: Flow Rate Pressure 5 Lpm / 1.32 Gpm 2.2 Bar / 32 Psi 15 Lpm / 3.96 Gpm 1.9 Bar / 28 Psi20 Lpm / 5.28 Gpm 1.6 Bar / 23 Psi Plumbing Connections Inlet ( Feed Water Connection ) 3 / 4 Bsp Loop Start / Return 1 1 / 2 Sanitary Tc Drains 3 / 8” Lab Water Purification Systems - Type 2 ( Pure ) , Muffle Furnace : Controller: Should Be Microprocessor Based & At Least 8 Segment Programmable Or Equivalent Controller With Necessary Safety Features. Programmable Temperature ( Pid Controller ) Controller With Heating Rate Control From 10?C / Min To 40?C / Min. ( Fast Heating Rate Would Be Preferable ) , Heating Element :Kanthal A1 And Backed By High Temperature Ceramic Insulation , Safety: Over Temperature Protection& Over Load Protection ( Safety Controller ) Should Provided. Door Safety Switch Must Be Provided So That It Disconnects Power Supply To Heating Element When Door Opens. Should Be Equipped With Digital Over Temperature Protection Circuit To Fail Safe In The Event Of A Controller Malfunction , Critical Electronics Component And Heating Elements Protected By A 35A Circuit Breaker., Weight : Less Than 100 Kg , Two Set Of Operation And Maintenance Manual Should Provided. , Ph Meter : Supply Of Bench Top, Digital Ph Meter Along With All Its Accessories And Spares Required Brand Name And Model Name Must Come In The Display. To Operate The Instrument As Per Specification Given Below: The Direct Reading Laboratory Ph Meter ( Digital ) Operable At 230V + / - 10V A.C., 50 Hz Powersupply With Necessary Cable Connections And Other Standard Accessories Required For Smoothoperation. Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2, Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C, Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C, Temperature Compensation : It Should Have Both Automatic And Manual Temperaturecompensation Touch Screen Display , Parameters Likeph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level.Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter. Storage Of Instrument : It Should Be Able To Stored In Temperature Of 5 To 40 °C And Relative Humidity Of 5 To 80% ( Non-Condensing ) Glp Compliance : It Should Be Glp Complied .To Improve The Reproducibility, It Should Allow To Choose From At Least Three Endpoint Criteriaaccording To Our Requirements.The Electrode Holder Should Move In A Perfectly Vertical Way, Making It Easy To Place The Sensor In The Perfect Position I.E. Vertically In The Measurement Beaker. It Should Be Able To Connect Peripherals Via Usb And Rs232, Increasing Its Possibilitiessignificantly. Export Of Measurement Data And Calibration Data Should Be Possible To Usb Stickto Direct Pc Software Whenever Required By Us. It Should Allow Monitoring Of Limits Of Parameter Ph By Giving A Warning Message When The Value Falls Below Or Exceeds The Predefined Limits. It Should Have Facility Not To Delete Of Data And Changing Of Settings In Routine Mode. Hence It Required To Be Pin Protected For Login, Deletion Of Data, System Settings Etc. It Should Have Choice Of Endpoint Formats Like Automatic, Manual And Timed. It Should Have Choice Of Ph Decimal Places Like X.Y, X.Yy & X.Yyy ( Up To One, Two Andthree Decimal Places. ) It Should Have Data Storage Up To 1000 Measurements ( Min. ) It Should Have Ph Sensor Input Through Bnc Connector With Impedance Of More Than 3 X 1012O . It Should Have Temperature Sensor Input. It Should Be Able To Show The Quality Of Last Calibration On Its Screen. , Precision Drier : Capacity, Material And Construction: Cap:3Ltr / H Evaporation Rate. Suitable For Aqueous Feed Solution. Laboratory Scale Model. External Body –Ss316. Drying Chamber And Cyclone In Full Ss 316L Construction. Total Construct Size: 1200 X 1300 X 2000 Mm ( ±10% Dimesional Tolerance ) , Self-Supported On Castor / Wheels ( Compressor Size Is Extra ) . Weight: Max 130 Kg ( ±20% ) ( Compressor Weight Is Extra ) Chamber: Chamber Size: Diameter-280-350Mm, Length- 600-1000 Mm, With Conical Bottom. Feed Pump: Variable Speed Gearless Peristaltic Pump With Dual Teflon Rollers And Precise Speed Control. Feed Pump Should Be Of Repute Make Preferable Watson Marlow / Miclin / Flowtec Or Equivalent. Silicon Tube For Feed. Pump Should Be Controlled Through Plc And Manually As Well. Spray System And Nozzle:Moc For Two-Fluid Spray Nozzle: 316L Variable Aperture Nozzle Of 0.7Mm.Other Sizes Such As 0.5 / 1.0 / 1.2 / 1.5 / 2.0 / 2.5 Mm May Be Available. Auto De-Blocking System For Spray Nozzle Which Will Be Fitted On Nozzle Controlled Through A De-Blocker Timer. An Additional Spray Aperture For Future Use Should Be Included. Nozzle Geometry And Design Must Be Submitted With A Tender Document. Desired Output Particle Size Range 20-45 Micron, Compatible With Ceramic Slurry Also. Controller And Display: Plc Based Operating System With A Multi-Touch Colour, Interface, 9” Hmi With Data Logging, Online Trends, Recipe Functionand Ability To Store Recipes And Recall For Ease Of Use. Plc Of Repute Make Such As Siemens, Delta Or Equivalent Etc. Thesystem Should Have An Audio Visual Alarm For A. Inlet Temperature, Outlet Temperature And Atomization Pressure. Thesystem Should Have Parameter Control And Safety Interlock. Inlet / Input Air Temperature / / Temperature Range: Ambient To Minimum 260 Degrees C, Variable And Selectable Aspirator Airflow:Max. 150 Cum 3 / Hr With Vfd For Motor Control Of Repute Make Such As Delta, Fuji Or Equivalent Air Heater:Electrical Heater With Minimum 6.0Kw Capacity Inlet Filter:Combination Type ( Pre + Hepa ) For Pre-Filtering Environment Air To Keep Most Impurities And Particles Away From The Spray Drying Process, Outer Filter Assembly: Mainly To Protect Aspirators From Fine Particles. It Should Include Spun Bound Polyester Cartridge With Ptfe Coating. Efficiency- 1Micron Down To 99.99%.Compressor: Oil-Free Air Compressor Piston Type With Min. 20L Air Reservoir 1Hp Power Supply: Single-Phase, Compatible With Indian Standard , Quartzdouble Distilled Water Plant: All Quartz, Material Of Distillation Unit Shall Be Made Of High Purity Electronic Grade Transparent Quartz Only, Heaters: Demountable Boiler Panel With Compact Design Of Boilers & Condensers Easily Mountable For Cleaning And Maintenance With Spiral Heaters, Electrical Requirement: 230-250 Volts 10 / 50Hz, Single Phase, Dist. Water Output Capacity ( Ltr / Hr ) : 2.5 Ltrs / Hr, Total Power Consumed-4.4 Kw, Conductivity ( ?S / Cm ) : <1*10-6, Distillation Units Type-Vertical, Biological Activity-Pyrogen Free, Double Stage Glass ( Quartz ) Distillation Units-Yes, Double Wall Condenser- Quartz, Cooling Water Consumption ( Ltr / Hr ) -2 Ltrs / Min, Boiler-Quartz, Demountable Model And Should Be Connected With Rubber Tumbling And Pinch Cock For Cleaning Sediments In Primary Boilers And Must Be Ce / Iso Certified.Primary Boiler Provided With O Ring Accessories Distillation Apparatus Power Supply ( Daps ) : The Unit Provides For Automatic Working Of Distillation Unit By Switching Off The Heaters In Case Water Level Falls Below The Heating Coil, There By Safeguarding The Heaters. The Unit Resumes Distillation When Water Level Is Restored. The Unit Also Comes With Buzzer. Apart From The Above Features, Dual Cut Off: The Dual , Quartz Single Distilled Water Plant: All Quartz, Material Of Distillation Unit Shall Be Made Of High Purity Electronic Grade Transparent Quartz Only, Heaters: Demountable Boiler Panel With Compact Design Of Boilers & Condensers Easily Mountable For Cleaning And Maintenance With Spiral Heaters, Electrical Requirement: 230-250 Volts 10 / 50Hz, Single Phase, Dist. Water Output Capacity ( Ltr / Hr ) : 2.5 Ltrs / Hr, Total Power Consumed-2.2 Kw, Conductivity ( ?S / Cm ) : <1*10-6, Distillation Units Type-Vertical, Biological Activity-Pyrogen Free, Single Stage Glass ( Quartz ) Distillation Units-Yes, Double Wall Condenser- Quartz, Cooling Water Consumption ( Ltr / Hr ) -1 Ltrs / Min, Boiler-Quartz, Demountable Model And Should Be Connected With Rubber Tumbling And Pinch Cock For Cleaning Sediments In Primary Boilers And Must Be Ce / Iso Certified. Distillation Apparatus Power Supply ( Daps ) : The Unit Provides For Automatic Working Of Distillation Unit By Switching Off The Heaters In Case Water Level Falls Below The Heating Coil, There By Safeguarding The Heaters. The Unit Resumes Distillation When Water Level Is Restored. The Unit Also Comes With Buzzer. Apart From The Above Features, Dual Cut Off: The Dual Cut Off Switches Off The Heater Even When There Is No Cooling Water Supply To The Condenser. , Refrigerator : Frost Free Refrigerator : Auto Defrost Function To Prevent Ice-Build Up Capacity 253 Ltrs : Suitable For Small Families And Bachelors | Freezer Capacity: 69 Ltrs Fresh Food Capacity: 184 Ltrs Digital Inverter Compressor – Enjoy Greater Energy Efficiency, Less Noise And A Long-Lasting Performance. It Automatically Adjusts Its Speed In Response To Cooling Demand Shelf Type: Spill Proof Toughened Glass Shelves With Easy Slide Special Features: Easy Slide Shelf, Door Alarm, Inverter, Temperature Control, Cool Pack, Stabilizer Free Operation ( 100 ~ 300 V ) Key Feature : All Round Cooling For Even Cooling Corner To Corner | Power Cool - Enjoy Rapid Cooling Performance | Moistfresh Zone - Preserve The Freshness And Flavor Of Fruit And Vegetables For Longer | Interior Led Light | Moveable Ice Maker | Tall Bottle Guards | Recess Door Handle | Fresh Room | Deodorizer | R600a Refrigerant , Refrigerator-Temperature Control : The Upright Freezer Type Comes With An Abs Make Interior. Its Outer Body Is A Painted Steel Board, The Door Comes With A Handle And A Safety Lock On It, There Are Casters Provided For Easy Handing, Its Inner Drawers Are Made Of Plastic Control System : Uses A Microprocessor-Based Temperature Controller • The Temperature Control Range Is Adjustable Between -10°C To -20°C • It Has A Digital Temperature Display, Equipped With Audio Such As: High Or Low Temperature Alarm, Chamber Volume 270Ltr, Chamber Dimensions 800X500x500 Outer Dimension 1060X695x792 Input Voltage 230Vac 50Hz , Semi-Automatic Nitrogen Protein Analyzer : Analyzer Should Be Semiautomatic System Consisting Of A Digestion Unit, A Scrubber Unit, And A Distillation Unit. Digestion Unit: Automated With Integrated Programmable Control, Should Have Electrically Heated ( 230 ± 10 Volts, 50 Hz Ac ) Metal Blocks. It Should Be Capable Of Providing A Temperature Range From 100°C - 440°C With ±10°C Repeatability. Should Have Inbuilt Temperature Controller With Digital Display And Led Display Along-With Manual Temperature Adjustment. Heating Time Setting With Steps From 1- 150 Minutes Should Have The Capacity To Accommodate At Least Eight Numbers Of Digestion Tubes Each Of At Least 250Ml Capacity , Should Have Leak Proof Integrated Condensers ( Fumes Carriers ) Made Up Of Glass, Fixed On A Movable Panel Along With Adopter For Outlet To The Scrubber Unit. Proper Digestion Exhausts System. Scrubber Unit Should Be An Oil Free Centrifugal Suction Type, With Manual Vacuum Adjustment Facility. Corrosion And Impact Resistant Provided With Condensate And Acid Fumes Collection Vessels. Should Operate On 230 ± 10 Volts, 50 Hz, Ac Power Supply. Distillation Unit Fully Programmable Distillation Unit Including Sample Dilution, Alkali And Receiver Addition, Distillation And Tube Draining Facility. Validated Procedure / Certification For Tkn Distillation Like Aoac, Epa, Din, Iso Etc, Should Be Made-Up Of Standard Quality Borosilicate Glass. Should Possess A Steam Generator Made-Up Of Borosilicate Glass Along With Heater And Have 3 Step Manual Control Facility I.E. Standby, Water Inlet And Distillation. Should Have Inbuilt Bellows Pump For Accurate Reagent ( Alkali / Acid ) Dispensing. Should Have Ventilation Valve. Should Have Timer For 5 - 15 Minutes With Audio Signal. Steam Inlet Tube Should Be Of Ptfe. Unit Should Have Quick Clamping Device For Digestion Tube With Adaptor. Should Operate On 230 ± 10 Volts, 50 Hz, Ac Power Supply. Complete Unit Shouldprovided With One Set Of Digestion Tubes Along-With The Servicing, Operating And Maintenance Manuals. Can Able To Monitor And Measurement Of Distillate Temperature. Self Adjusting Cooling Water Control Facility Safe Feature For Safe Distillation. Can Be Upgradeable Whenever Required Accessories: 2 Set Of Digestion Tubes, Digestion Tube Stand, Spillage Tray For The Condensers, Tube Removing Device , Soxhlet’S Apparatus : Body Constructed In Ms Epoxy Coated Finish , Featuring Use Of Mantle Type Heaters That Comes With Support Of Energy Regulator, Capability To Handle 6 Tests, Can Handle Flasks Of 250Ml Capacity, Supplied Withsupport Of Clamps As Well As Rubber Tubing, Works On Electric Supply Of 220 / 230 Volts, 50 / 60 Hz Ac, Suitable To Heat Soxhlet Flasks Of 250Ml , Top Loading Balance: Maximum Capacity ( Or ) Range Of The Balance80-90 / 220 Gm Readability 0.01 Mg ( 0.00001 Gm ) / 0.1 Mg ( 0.0001 Gm ) Tarring Range 0 – 220 Gm Display Backlit Graphics Display / Lcd With Touch Screen Operation. Repeatability ( Standard Deviation ) 0.03 Mg ( Small Range ) / 0.10 Mg ( Large Range ) , Linearity ±0.20 Mg / ±0.10 Mg, Eccentric Load 0.30 Mg, Calibration Adjustment With Internal Weights, Fully Automatic Calibration Technology With Temperature Controlled, Data Memory Function For Keeping Weighing Data & Calibration History Data, 10 Sensitivity Drift ±2Ppm / °C ( When Automatic Self Calibration Is Not Used ) Stabilization ( Typical And Fast ) Approx. 4.0 Sec ( 0.1Mg ) / 15 Sec ( 0.01Mg ) , Size Of Weighing Pan ~ 80 - 90 Mm, Shielding Glass Draft Shield With Flexible Configuration Protective Cover For The Terminal, Replaceable Feed Through For Weighing Below The Balance, Power Supply To Be Operable With 230 V Ac, 50 Hz Power Supply. Accessories Power Supply Cable With All Accessories For Operation, Operating & Service Manual 2 Sets ( Of Hard Copies ) With Calibration Certificate Of The Balance. Soft Copy Of Instrument Operating Manual To Be Sent During The Time Of Installation, Interface Standard Bi-Directional Rs-232 Interface, Dust Cover One. , Ups For The Laboratory : 10Kva - 192V-8Kw Online Ups , 16Nos External Battery Module With Iron Rack, Ups / Automatic Bypass Facility, True Double-Conversion Online Ups, Microprocessor Control For Higher Reliability. Pure Sine Wave.Input Power Factor Correction. Wide Input Voltage Range ( 110 V – 300 V ) . Generator Compatible, Selectable Charging Current - Allows Flexibility To Add Any Battery Size, Emergency Power Off , Uv-Visible Spectrophotometer : Double Beam ( 185-1100Nm ) Spectrophotometer With Standalone Colour Lcd Display With Pc Controlling Software -Optical System: Double Beam, Diffraction Grating -Minimum 1800 Lines / Mm, Scan Speed :6000Nm / Min, 8 Position Sample Holder, Photometric Details Range Must Cover From -4 To + 4, Bandwidth Variable ( 0.2Nm -6Nm ) Stray Light < 0.05% T @ 220, 340 ( Must Cover Less Than 370Nm ) , Baseline Flatness Must Cover +- 0.006A, Detector- Photodiode / Single Photodiodes / Dual Silicon Photodiodes, Power 240+- 10%, 50-60 Hz, Light Source- Xenon Flash Lamp, Wavelength Details-, Accuracy- Must Cover 1.0Nm, Measuring Modes- Absorbance, Transmittance ( % ) , Concentration, Operating Modes: Single Wavelength, Multiple Wavelength, Time Scan, Data Presentation- Display Analysis Results And Graphic Data On Screen, Pc Link Software, Port To Data Transfer, Supplier Should Provide Service For Installation, Demonstration, Training For All Operation Procedure, Temperature Range- Operating Conditions Should Cover +10 Degree C To 40 Degree, Analytical Quality Assurance- Instrument Should Have Internal Quality Assurance Tools, Certification- Must Comply Ce Certificate. Accessories: Quartz Cuvettes: 50Mm Length, 10Mm, 20Mm Path Length ( Each 2 Pairs ) , Original Catalogue To Be Enclosed. Dedicated Branded Pc To Be Quoted With The System .Should Have Manufacturer’S Service Centre In West Bengal And Details Location To Be Mentioned In The Quotation.. , Vertical Autoclave : Quality Systems For Medical Devices Built: • Floor Standing Vertical Type Top Loading Autoclave • Outer Dimensions: Width 75-87 Cm; Height 90-110 Cm; Depth 65-80 Cm Software Control:• Fully Microprocessor Based Proportional Integral Differential ( Pid ) Pressure Control• Controller And Software Should Comply With International Standards Such As 21 Cfr Part 11 Or Any Other Equivalent.• Should Have Facility To Store Identification Codes And Password Codes For Access Level Control• Built –In Memory To Store Number Of Cycles Sensors:• Should Have In-Built Platinum Resistance Temperature Detector With A Typical Resistance Of 100 O At 0°C That Complies With International Standards Of Safety Requirements For Electric Equipment For Measurement Control And Laboratory Use, Eg. Iec61010-1, Iec 61010- 2-040 • Option To Connect Additional Temperature Sensors And Pressure Sensors Should Be Available Display:• User Interface Should: • Be Easy To Operate• Have Digital Display Enabling Visualization Of Stage Of The Cycle, Set And Process Temperature, Pressure And Quick Access To Important Information • Preferably Have Graphical Display Of Temperature And Pressure• Have Notification For Replacement Of Filters After Appropriate Number Of Runs Performed. Chamber Volume: Should Be Not Less Than 100 Litres And Preferably Should Be 150-180 Litres In Capacity. Suitable Number Of Basket For Bottle, Vessels Or Agar Media Preparation Should Be Quoted Along With The Instrument.Chamber Material: Should Be Long Lasting, Made Up Of 316Ti Grade Stainless Steel Of Asme / Ul Grade Chamber Pressure: Chamber Should Be Designed To Withstand At Least 2.8Bar / 142°C And Should Meet, European Pressure Equipment Directive ( Ped 97 / 23 / Ec ) .2 | 2 Chamber Heating: Should Be Heated Uniformly By A Heating Plate On The Outer Wall With Heater Of Suitable Wattage For Quick Heating.Chamber Insulation: Chamber Should Be Completely Insulated With Chloride Free Glass Wool. Sterilization Temperature Range: 105°C To 137°C With Accuracy Of ± 0.1 Deg C At 121 Deg C & An Additional Isothermal Temperature Range Of 60°C To 105°C. Should Have Feature Minimizes The Time Liquids Are Exposed To High Temperatures During Sterilization Thereby Protecting Liquid Media, Saving Laboratory Time And Reducing Energy Consumption. Biohazard And Waste Management System: Should Have The Facility To Filter Air Removed From Chamber Before Sterilization That Isuseful For Sterilization Of Biohazard Waste.Safety: • Water Level Monitoring And Maintenance Of Constant Level For Safety Of Heaters. • A Safety Device To Prevent Opening The Door When The Chamber Is Pressurized. • Prevent Starting Of Runs If Doors Are Improperly Locked.• Safety Feature Should Allow Opening Of Doors Only When The Temperature Reaches A Pre-Set Temperature And Pressure Reaches Atmospheric Pressure.Power Requirement: A Suitable Size Of Electrical Switch Gear 3 Phase 440 Volt With Earthing Andrecommended Size Of Current Capacity Mccb Will Be Made Available On Wall At Appropriate Place. Other Connection And Installation Has To Be Done By The Supplier. , Hydrometer , Keen Boxes , Aluminium Box , Brass Sieve , Mortar And Pestle , Different Types Of Augers: , Screw Type , Post Hole Type , Dutch Type , Stirrera. Magnetic B. Electric , Khurpi , Electric Heater , Room Thermometer , Gps Machine , Camera , Lcd Projector
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 28
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Uttarakhand View Result →
38.
Power #8727251 Technical Bid
Tender For Carrying Out Routine Maintenance And Calibration Of All Instruments And Equipments In Mrt Sub-Division For The Period From 01.04.2020 To 30.09.2020 At Vgtps / Phase-Ii. - 2 Calibration Of Voltmeter / Ammeters / Timers Includes Safe Release Of Meter / Timer From Panel / Testing Of Meter & Meter And Physical Verification, Cleaning Attending Minor Defects, Repairs / Adjustments, Refixing Of Meter / Timer, Checking For Correctness And Restoring Normalcy, Handling Of Testing Kits / Equipments And Maintaining Of Registers Etc, As Directed By The Engineer In Charge. 3 Calibration Of Kw / Kvar / Pf / Kwh / Trivector Meter And All Transducers Including Safe Release Of Meter / Transducer From Panel / Testing And Physical Verification, Cleaning Attending Minor Defects, Repair / Adjustment, Refixing, Checking For Correctness And Restoring Normalcy, Handling Of Testing Kits / Equipment And Maintaining Of Registers Etc, As Directed By The Engineer In Charge. 4 Calibration Of Bimetallic Relays Electromagnetic Relays And Static Relays Including Safe Release Of Relay From Panel / Testing Relay And Physical Verification, Cleaning Attending Minor Defects, Repair / Adjustment, Refixing, Checking For Correctness And Restoring Normalcy, Handling Of Testing Kits / Equipment And Maintaining Of Registers Etc, As Directed By The Engineer In Charge. 5 Testing Of Numerical Relays, Ct, Pt, Cvt, Surge Arrester / Capacitors ( Hv / Ehv ) Including Safe Release Of Relay From Panel / Testing Of Relay And Physical Verification, Cleaning Attending Minor Defects, Repairs / Adjustments, Refixing Of Relay, Checking For Correctness And Restoring Normalcy, Handling Of Testing Kits / Equipments And Maintaining Of Registers Etc, As Directed By The Engineer In Charge 6 Testing Of Avr, See / Sfc , Generators, Power Transformers , 110Kv And 11Kv Circuit Breakers Handling Of Testing Kits / Equipments And Maintaining Of Registers, Etc, As Directed By The Engineer In Charge. 7 Testing And Troubleshooting Of Breakers Upto 6.6Kv Rating, Lighting Transformers, Ht And Lt Motors, Handling Of Testing / Equipments And Maintaining Of Registers Etc, As Directed By Engineer In Charge. 8 Lubricating Cleaning, Checking Of Control Circuits Tightness And Healthiness In Both End ( Local And Module End ) , Disconnection And Reconnection Of Control Cables On Motorized Valve / Smart Movs And Maintaining Of Registers Etc, As Directed By Engineer In Charge. 9 Limit Setting Of Torque And Limit Switch Of Motorized Valve / Smart Movs Checking Of Control Circuits And Maintaining Of Registers Etc, As Directed By Engineer In Charge. 10 Troubleshooting Of Control Circuits Problems In All Type Of Lt & Ht Modules, Checking For Tightness Healthiness Cleaning Of All Type Of Control And Relay Panels, Ups, Chargers, Lt & Ht Module, Control And Annunciation Panels, Fire Panels, Fire Detectors And Co2 Fire Protection Etc, And Maintaining Of Registers Etc, As Directed By Engineer In Charge. 11 Troubleshooting And Cleaning Of Scada, Routine Maintenance Of Cctv, Intercom, Pa System , Bio Metric And Lan. 12 Assistance To The Maintenance Engineers During Gtg & Stg Startup And Shutdown, Commissioning Of New Equipment & Other Activities As Directed By Engineer In Charge. 13 Monitoring, Taking Daily Walk Down Check List Of All Important Parameters In The Station, Checking Of All Fire Systems And Checking Of All Intercom Xconnection Healthiness.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 23.48 Lakh
Boards / Undertakings / PSU No of Bidders 2
40.
Educational and Research Institute #8449023 AOC
Tender For Supply Of Library Books => Limited; 1 LIBRARY BOOKS FOR MECH 2 Industrial Machinery Repair: Best Maintenance Practices Pocket Guide 3 Design Data Book 4 Handbook of Simulation: Principles Methodology, Advances, Applications and Practice (PB) 5 Modern Arc Welding Technology (HB) 6 Comprehensive Injection Moulding (PB) 7 Problems in Engineering Mechanics (PB) 8 Fundamentals of Heat and Mass Transfer 9 Design Data Book: Properties of Steam, Selected Refrigerants, n-Hexane and Brines 10 Introduction to Chemical Equipment Design: Mechanical Aspects 11 A Textbook of Statistical Mechanics, 2e (HB) 12 Workshop Technology, 4e Vol. II 13 Workshop Technology, 5e Vol. I 14 Workshop Technology, 3e Vol. III 15 Textbook of Dynamics, 2e 16 Textbook of Fluid Dynamics 17 Mechanics of Materials, 2e (PB) 18 Nuclear Reactor Engineering, 4e Vol. I : Reactor Design Basics (PB) 19 Nuclear Reactor Engineering, 4e Vol. II : Reactor Systems Engineering (PB) 20 Project Planning & Management 21 Maleev & Hartmans Machine Design, 6e 22 Fluid Mechanics, Fluid Machines and Hydraulics, 3e (With 500 Solved Problems) 23 Laboratory Manual of Fluid Mechanics & Machines 24 Theory & Design of Pressure Vessels 25 Automotive Mechanics: Principles & Practices, 2e 26 Machine Design II: A Concise Approach (PB) 27 Machine Design II: A Concise Approach (PB) 28 Design and Engineering, 2e (PB) 29 GATE Instrumentation Engineering: MCQs with Detailed Solutions 30 Steam Turbine Theory and Practice, 7e 31 Theory of Machines (PB) 32 Solid Mechanics Theory And Finite Element Analysis (PB) 33 Principles of Air Conditioning, 3e 34 Tractors and Their Power Units, 4e (HB) 35 Tractors and Their Power Units, 4e (PB) 36 Production Processes (PB) 37 Multicourse Textbook For Students of Diploma In Mechanical Engineering (PB) 38 Sheet Metal Press Tools Design and Making: A Practical Approach (PB) 39 Design Data Handbook for Mechanical Engineers in SI and Metric Units, 4e 40 Principles of Refrigeration, 2e 41 Textbook of Fluid Mechanics 42 Primer on Caed to Learn Solid Edge in 8 Days (PB) 43 Mass Transfer Operations Theory And Applications 2Ed (PB) 44 Mechanics and Strength of Materials (PB) 45 Mechanics and Strength of Materials (PB) 46 Design of Machine Elements I DME I (PB) 47 Design of Machine Elements I DME I (PB) 48 Design Of Machine Elements Ii Dme Ii 2Ed (PB) 49 Numerical Techniques and Computer Programming For Engineering Problems (PB) 50 Unconventional Machining Processes Fundamental Principles And Recent Developments (PB) 51 Management Science and Industrial Management (PB) 52 Management Science and Industrial Management (PB) 53 Management Science and Industrial Management 54 Metal Cutting Principles (PB) 55 Problems and Solutions in Engineering Thermodynamics 56 The Theory of Machines, 3e 57 Theory of Vibration with Application, 3e (PB) 58 Mechanical Vibrations: Theory and Applications, 2e 59 Engineering and Managerial Economics (PB) 60 Computational Fluid Dynamics Laboratory Manual (PB) 61 Comprehensive Injection Moulding (HB) 62 Nanotechnology, Vol. 1 (HB) 63 Hydrodynamic Flow Instabilities in Power Equipment Components 64 Power Equipment Engine Technology (PB) 65 Mechanics for Engineers: Dynamics (PB) 66 Mechanics for Engineers: Statics (PB) 67 Refrigeration and Air Conditioning Technology, 8e (PB) 68 Fundamentals of Modern Drafting, 2e (PB) 69 Practical Ship Hydro Dynamics, 2e (PB) 70 Ship Hydrostatics & Stability, 2e (PB) 71 Newnes Control Engineering Pocket Book 72 Air Conditioning System Design Manual, 2e (PB) 73 Mechanics of Materials- A Modern Integration of Mechanics & Materials in Structural Design 74 Stability & Safety of Ships: Regulation & Operation, Vol.1 (PB) 75 Jones’ Instrument Technology: Mechanical Measurements, 4e Vol. 1 (PB) 76 Jones’ Instrument Technology: Measurement of Temperature and Chemical Composition, 4e, Vol. 2 (PB) 77 Jones’ Instrument Technology: Electrical & Radiation Measurements, 4e, Vol. 3 (PB) 78 Jones’ Instrument Technology: Instrumentations Systems, 4e, Vol. 4 (PB) 79 Jones’ Instrument Technology: Automatic Instruments and Measuring Systems, 4e, Vol. 5 (PB) 80 Light & Heavy Vehicle Technology, 4e (PB) 81 Principles of Combustion, 2e (PB) 82 Understanding Aircraft Structures, 4e(PB) 83 Vibration of Continuous Systems (HB) 84 Shop Theory, 6e (PB) 85 Project Management (HB) 86 Engineering Design, 4e (PB) 87 Tool Design, 5e (SIE) (PB) 88 Turbomachinery (PB) 89 Thermodynamics Basic and Applied (PB) 90 Schaums Outline Of Fluid Dynamics 3e (PB) 91 Schaums Outline Of Mechanical Vibrations (PB) 92 Finite Element Analysis Theory and Programming, 2e (PB) 93 Schaums Outline Of Continuum Mechanics (PB) 94 Machine Tool Design and Numerical Control, 3e (PB) 95 Engineering Mechanics Statics and Dynamics (PB) 96 Instrumentation and Control Systems (PB) 97 Non Destructive Test and Evaluation of Materials, 2e (HB) 98 Fluid Mechanics, 9e (PB) 99 Engineering Mechanics, 5e (PB) 100 Theory of Elasticity, 3e (PB) 101 Mass Transfer Operations, 3e (PB) 102 Machine Design, 3e (PB) 103 Engineering Design A Modern Approach (PB) 104 Fundamentals of Fluid Mechanics (Pub. Price: $ 72.67) (PB) 105 Fluid Mechanics With Engineering Applications, 9e (PB) 106 Schaums Outlines Fluid Mechanics and Hydraulics, 3e (PB) 107 Wind Energy Engineering (PB) 108 Introduction to Digital Signal Processing (PB) 109 Fundamentals of Mechanical Design, 3e 110 Automatic Control Engineering, 5e (Pub. Price: $ 118.33) (PB) 111 Boundary Layer Theory, 7e (PB) 112 Mechanics of Fluids, 3e (Pub. Price: $134.32) (PB) 113 Kinematic Analysis of Mechanisms, 2e (PB) 114 Refrigeration and Air Conditioning, 2e (Pub. Price: $ 140.33) (PB) 115 Principles of Mechanics, 3e (PB) 116 Principles of Mechanics, 3e (PB) 117 Modern Arc Welding Technology (HB) 118 Viscous Fluid Dynamics (PB) 119 Design of Machine Tools, 6e (PB) 120 Fundamentals of Internal Combustion Engines, 4e (PB) 121 Mechanics of Materials-Formulas and Problems No.2 (PB) 122 Engineering Mechanics 123 Physical Chemistry of Iron & Steel Manufacture 124 Physical Metallurgy for Engineers 125 Physical Chemistry of Metals 126 Problems & Solutions in Engineering Mechanics 127 Physical Metallurgy (PB) 128 Foundry Technology 129 Engineering Physical Metallurgy 130 A Dictionary of Metallurgy (PB) 131 A Dictionary of Metallurgy 132 Principles Industrial Metalworking Processes (HB) 133 Principles Industrial Metalworking Processes (PB) 134 Metal Cutting Principles 135 Cast Iron Technology, Vol. 2 (PB) 136 Cast Iron Technology, Vol. 1 (PB) 137 Corrosion of Metals (PB) 138 Paper 1:GS- Genral Principles of Design Drawing & Importance Of Saftey 139 Paper 1:GS- Standards and Quality Practices in Production,Construction,Maintenance and Services 140 Paper 1:GS- Basic Of Energy and Environment 141 Paper 1:GS- Basic Of Project Management 142 Paper 1:GS- Basic Of Material Science 143 Paper 1:GS- Information and Communication Technologies 144 Paper 1:GS- Ethics and Values in Engineering Profession 145 General Studies & Engineering Aptitude Practice Book 3300 + MCQ 146 General Studies and Engineering Aptitude Topicwise Objective 8 Year Solved Papers 147 Preliminary Exam: Mechanical Engineering Objective Paper - Volume-2 148 Mains Examination: Mechanical Engineering Conventional Paper - I 149 Mains Examination (Practice Book): Mechanical Engineering Conventional Paper - I 150 Mains Examination (Practice Book): Mechanical Engineering Conventional Paper - II 151 Engineering Mathematics for GATE and ESE (Prelims)-Theory and Previous Year Solved Papers 152 General English for GATE and PSUs -Theory and Previous Year Solved Papers 153 Mechanical Engineering- Practice Book for ESE, GATE & PSUs 154 Mechanical Engineering : Previous Solved Papers 155 JE Mechanical Engineering (2024)- Previous Year Objective Solved Papers- 1 156 Civil and Mechanical Engineering : SOM 2nd Edition 157 Strength of Materials : 2nd Edition 158 A Text Book on Production Engineering 159 State Engineering Services Examination : CE Objective Solved Paper 160 : History of Medieval India 161 History of Modern India 162 History Of Post Independence India 163 History Of The World 164 Science and Technology 165 International Relations 166 Internal Security 167 Indian Society 168 Indian Polity 169 Indian Geography and Disaster Management 170 Indian Economy 171 Governance Of India 172 Ethics, Integrity and Aptitude 173 Ecology and Environment 174 AE- General Knowledge 175 AE- Indian Polity 176 AE- Science & Technology 177 2700 MCQs : Practice Book General Engineering 178 Current Affairs MADE EASY Annual Edition 2024 179 Current Affairs Quarterly Issue: Jan-Feb-March 2024 180 Steam Tables with Mollier Diagram 181 Steel Tables (M.K.S. & S.I. Units) 182 Basics of Mechanical Engineering for Diploma Engineer by GKP 183 Objective Series Mechanical Engineering by G K Mithal 184 GATE 2025 General Aptitude - Guide by GKP 185 GATE 2025 - Mechanical Engineering - 25 Years Chapter-wise Solved Papers (2000-2024) by GKP 186 GATE 2025 Mechanical Engineering - Guide by GKP 187 GATE 2025 Mechanical Engineering - 38 Years Topic-wise Previous Solved Papers by GKP 188 GATE 2025 Mechanical Engineering - Solved Papers (2000-2024) by GKP 189 GATE 2025 - Mechanical Engineering - 25 Years Topic-wise Previous Solved Papers (2000-2024) by GKP 190 GATE 2024 Engineering Sciences - Previous Years Solved Papers 2009-2023 (Section-Wise) by GKP 191 GATE 2024 Metallurgical Engineering - Guide by GKP 192 SSC 2024 Junior Engineers - Mechanical Engineering - Guide by GKP 193 SSC 2024 Junior Engineers - Paper I - Mechanical Engineering - 42 Previous Years Solved Papers (2008-23) by GKP 194 SSC 2024 Junior Engineer - Paper I - Mechanical Engineering - 25 Solved Papers & 10 Practice Sets by GKP 195 SSC 2024 Booster Test Series - JE Paper I - Mechanical Engineering - 15 Mock Tests (includes 2019-2023 papers) by GKP 196 SSC 2024 - Junior Engineer - Paper I - Mechanical Engineering - Topic-Wise Solved Papers 2008-2019 (Latest paper included 2020 - 2023) by GKP 197 SSC Junior Engineer Paper II - Mechanical Engineering- Conventional Solved Papers (Exams Held between 2007-2021) 198 SSC JE (CPWD) Paper-I (22 Solved Papers 2008-18) Mechanical Engineering (Hindi) 199 SSC JE Paper I 2020 - (CWC/MES) Mechanical Engineering - Previous Years Solved Papers (2008-18) - Hindi 200 Mental Ability for NTSE & Other Talent Search Examinations 2016 by Ashish Arora 201 Electrical Power Transmission & Distribution (Engineering Reference Book) 202 Protection and Switchgear (Engineering Reference Books) 203 Principles of Electrical Engineering (Engineering Reference Books) 204 Electrical Drives and Actuators (Engineering Reference Books) 205 Sensor and Instrumentation (Engineering Reference Books) 206 Transformers and Generators (Engineering Reference Books) 207 Transmission and Distribution (Engineering Reference Books) 208 ITI Electrician Practical I & II Year English 209 Design with PIC Microcontrollers 210 Power System Optimization 211 Extra High Voltage AC Transmission Engineering 212 HVDC Power Transmission Systems 213 Non Conventional Energy Sources 214 Renewable Energy Sources and Emerging Technologies 2/E 215 SOLAR PHOTOVOLTAICS: Fundamentals, Technologies and Applications 2/e 216 Wind Electrical Systems 217 UTILISATION OF ELECT POWER 218 CIRCUIT AND NETWORK THEORY: FOR GATE, PSUs AND ES EXAMINATION 219 ANALOG ELECTRONICS: FOR GATE, PSUS AND ES EXAMINATION 220 CONTROL SYSTEMS: FOR GATE, PSUs AND ES EXAMINATION 221 MICROPROCESSORS: FOR GATE, PSUs AND ES EXAMINATION Please Enable Macros to View BoQ information
Contract Date: Dec 17, 2025 Contract Value : 10
Statutory Bodies & Commissions/Committees No of Bidders 3
41.
Educational and Research Institute #8289129 AOC
Tender For Supply Of Library Books Eee, Library Books For Eee , A Textbook Of Electrical Technology Volume – I: Basic Electrical Engineering , A Textbook Of Electrical Technology Volume – Ii: Ac And Dc Machines , A Textbook Of Electrical Technology Volume Iii , A Textbook Of Electrical Technology Volume Iv , Abc Of Electrical Engineering , Fundamental Of Electrical Engineering And Electronics (M.E.) , Principles Of Electronic Devices And Circuits , Basic Electronics: Devices & Circuits , Network Theory: Analysis And Synthesis , Objective Electrical Technology , Principles Of Power System , Concise Handbook Of Electronics And Electrical Engineering , A Textbook Of Digital Electronics , Electrical Machinery , Generalized Theory Of Electrical Machines , Electric Machines , Principle Of Electrical Machines , Electrical Machines , Electric Machines , Electric Circuit Theory , Problems & Solutions Of Eletric Circuit Analysis , A Fundamentals Of Hybrid And Electric Vehicles , A Text Book Of Electrical And Electronics Engineering Materials , Basic Formulae Book For Electrical Engineering , Conventional & Objective Type Questions & Answers On Electrical Engineering For Competitions , Electric Motor Drives , Digital Electronics , Digital Signal Processing , Ehv-Ac, Hvdc Transmission & Distribution Engineering , Electric Power Systems (Analysis, Stability & Protection) , Electrical And Electronics Engineering Materials And Components , Electrical Machinery , Electrical Measurements & Measuring Instruments , Electrical Networks & Circuits , Electrical Power Systems (Generation, Transmission, Distribution, Protection And Utilization Of Electrical Energy) , Electrical Substation Engineering And Practice Engineering & Practice Ehv-Ac, Hvdc And Sf6-Gis , Electromagnetic Field Theory (Including Antennas And Wave Propagation) , Electrician Trade Theory , Electrical Wiring Estimating And Costing , Fundamentals Of Maintenance Of Electrical Equipments , Experiments In Electrical Engineering , Emerging Technology , Electronic Measurements & Instrumentation , Power Transformers And Special Transformers , Power System Analysis & Stability , Objective Question & Answers In Electrical Engineering , Numerical Control Of Machine Tools , Utilization Generation & Conservation Of Electrical Energy , Theory Of Power Cable Accessories Cable Installation And Testing , Testing, Commissioning, Operation And Maintenance Of Electrical Equipments , Switchgear Protection And Power Systems (Theory, Practice & Solved Problems) , Study Of Electrical Appliances & Devices , Electronic Devices & Circuits , Electronic Devices And Circuits Theory , Op-Amps And Linear Integrated Circuits , Power Electronics , Power Electronics: Devices, Circuits, And Applications, 4E , Power Electronics: Converters Applications And Design, Media Enhanced, 3Ed , An Integrated Course In Electrical Engineering: With Theory And Objective Type Questions With Answers , Power System Analysis , Modern Power System Analysis , Electrical Power Systems , A Course In Electrical And Electronic Measurements And Instrumentation , Signals And Systems , Principles Of Electromagnetics , Sensors And Transducers , Transducers And Instrumentation , Power Plant Engineering , A Textbook Of Power Plant Engineering , Fundamentals Of Electric Circuits , Modern Control Engineering , Control Systems Engineering , Signals And Systems , Study Of Electrical Appliances & Devices , Handbook Of Repair & Maintenance Of Domestic Electronics Appliances , Domestic Appliances Servicing , Electrical Drives , Electric Drives , Power Electronics , Energy Efficiency And Management For Engineers , Renewable Energy: Power For A Sustainable Future , Electronic Product Design , Computer - Based Industrial Control , Electric Vehicle Battery Systems , Electrical Safety, Fire Safety Engineering And Safety Management , Energy Management: Policy Planning And Utilization , Raina K B_Electrical Design 2E , Control Of Electrical Machines , Programmable Logic Controllers , Power System Protection And Switchgear , Computer Aided Electrical Drawing , Handbook On Electrical Engineering Useful For Gate, Ese, Ssc, Rrb, Psus & Other Competitive Exams , Ese 2025 Prelims Electrical Engineering Objective Volume 1 Previous Questions With Subject Wise & Chapter Wise Solutions (32 Yrs) , Ese 2025 Prelims Electrical Engineering Objective Volume 2 Previous Questions With Subject Wise & Chapter Wise Solutions (32 Yrs) , A Handbook On Electrical Engineering , Ae Electrical Engineering Volume 1 ( Yct Publication ) , Ae Electrical Engineering Volume 2 ( Yct Publication ) , Bullet Pointer Electrical Engineering , Je Electrical Engineering Volume 1 ( Yct Publication ) , Je Electrical Engineering Volume 2 ( Yct Publication ) , Gate Electrical Engineering And Instrumentation Engineering Books 2026 (Set Of 2 Books) , Concept Booster Electrical Engineering For Ssc Je, Psus, Rrb Je, All State Ae/Je Exams | Formulas And Concise Concepts , Ae Je Exams Electrical Engineering Best 4500+ Topic Wise Questions , Ssc Je Electrical Engineering Smartbook With 3000+ Chapterwise Pyqs | Ideal For Ssc Je, State Ae/Je & Psu Exams , Ssc Je Electrical Engineering | Best 2500+ Topic Wise Previous Year Questions , Gate 2026 : Electrical Engineering - 26 Years Topic-Wise Previous Years Solved Papers (2000-2025) | Gate 2025 Fully Solved Paper | With Gateflix Test Series , Ssc-Je 2025: Electrical Engineering Paper-1 : 45 Previous Years Solved Papers (2008-24) | Includes 3 Practice Papers , Ssc-Je 2025-26: Electrical Engineering - Study Guide | Includes Solved Papers From 2017-2024 | Ssc - Electrical Junior Engineer Exam , Rrb Prime Series 2022-23: Junior Engineer Cbt-2 Chapterwise Question Bank - Electrical & Allied Engineering By Gkp , Rrb Junior Engineer 2022-23: Cbt-1 & 2 : Electrical & Electronics Engineering, Chapter-Wise & Year-Wise Solved Papers (2014, 2015 & 2019) -35 Sets By Gkp , Rrb Alp 2025 : Basic Science & Electrical Engineering Guide For Rrb Assistant Loco Pilot Stage-Ii Exam By By Gkp , Gkp Rrb 2024-25 - Junior Engineer Cbt -I & Ii - Electrical Engineering - Guide (Includes Solved Sets Of 2019 Cbt-I & Ii Exams) , Isro 2025: Electronics Engineering - 16 Previous Years Solved Papers (2008-2023) | For Scientist & Engineer Isro Exam Preparation | Includes 3 Practice Papers , Handbook Of Electrical Engineering | Useful For Gate, Psus, Isro, Drdo, Rrb-Je, Ssc-Je, Ae-Je, Upsc (Ese) & Other Competitive Exams , Objective Series: Electrical Engineering By G.K. Mithal | Ideal For For B.Tech, Gate, Psus, Ese & Other Competitive Exams , Basics Of Electrical Engineering For Diploma Engineers | Ideal For Ssc-Je, Rrb-Je, Drdo, Dmrc, Bhel & Other Engineering (Diploma) Competitive Exams , Mahatransco 2025-26: Electrical Assistant (Transmission) - Electrical Engineering Study Guide | Comprehensive Objective & Practice Questions | Mahatransco Exam Prep Book , Fci-Je 2025 : Electrical & Mechanical Engineering - Phase 1 & 2 Study Guide | Food Corporation Of India Junior Engineer Recruitment Exam | Includes Practice Paper , Coal India Ltd. 2025-26 : Management Trainee Study Guide For Electrical Engineering (Includes Cil 2020 Solved Paper And Gate 2021-24 Solved Papers) By Gkp , Dfccil 2025 : Electrical Engineering - Executive Cbt-2 Exam Study Guide | Includes Practice Paper , Upsc-Ese 2025: Electrical Engineering Solved Papers | 25 Years Chapter & Year Wise Solved Papers 2000–2024 | Perfect For Gate-Ee, State Engg. Services, Uppsc-Ae & Similar , Upsc-Ese 2025 : Electrical Engineering Study Guide | Prelims Exam Paper-2 | Includes Solved Papers From 2017-2024 | Ideal For State Engg. Services, Uppsc-Ae & More , Engineering Mathematics - Ese,Gate,Psus 2026 , Engineering Aptitude (Quantitative Aptitude And Analytical Ability) Ese, Gate, Psus 2026 , Ese 2026 - Non-Tech Books Ese Exams Preparation , Ese Prelims Paper 1 - General Studies And Engineering Aptitude Practice - Questions Book , Ese Prelims Paper 1 - General Studies And Engineering Aptitude , Ssc-Je 2025 Electrical Engineering Previous Years Topic Wise Objective Detailed Solution With Theory , Gate 2026 Electrical Engineering Practice Booklet Bits & Bytes Volume 1 With 1116 Expected Questions & Answers , Gate Electrical Engineering Practice Booklet Bits & Bytes Volume 2 With 1116 Expected Questions With Solutions , Gate 2026 Electrical Engineering Previous Gate Questions With Solutions, Subjectwise And Chapterwise , Isro Ec Subjectwise & Chapterwise Previous Years Questions With Solutions (2006-2022) , Genco | Transco | Discoms Electrical Engineering Previous Years Questions With Solutions, Subjectwise & Chapterwise Of Various Examinations (Previous 29 Papers Included) , Railway Recruitment Board – Junior Engineer Computer Based Test – Ii Electrical And Allied Engineering Previous Years Questions With Detailed Solutions Subject-Wise And Chapter-Wise (2014, 2015 And 2019) , Railway Recruitment Board Junior Engineer Cbt -I Previous Years Questions With Solutions, Subject-Wise And Chapter-Wise (2019) , Rrb Je Cbt-1: General Awareness, General Science , Rrb Je Cbt-1: Mathematics, General Intelligence , Rrb Je Cbt-2: General Awareness, Science And Technology , Gate-2026: Electrical Engineering Previous Year Solved Papers , Ese 2026: General Studies And Engineering Aptitude Topicwise Objective Solved Papers , General Studies- 2026 For Upsc, Ssc, Railways, Psus And Bank Po , Ese 2026: Preliminary Exam: Electrical Engineering Objective Solved Paper Vol-1 , Ese 2026: Preliminary Exam: Electrical Engineering Objective Solved Paper Vol-2 , Engineering Mathematics For Gate And Ese-2026 , 2900 Mcqs : Electrical Engineering- Practice Book For Junior Engineer , General Intelligence And Reasoning Practice Book For Junior Engineer , Ssc-Je: Electrical Engineering 2025- Previous Year Objective Solved Paper-1 Volume-1 , Ssc-Je: General Awareness 2025 Previous Year Objective Solved Papers , Upsc Civil Services Pre Exam: Electrical Engineering Previous Year Solved Paper , 3500 Mcq : Ies/Gate/Psus: Electrical Engineering , Isro, Drdo, Bsnl : Previous Years Solved Papers Of Electronics Engineering , Uppsc-Ae 2024: Prelims Exam 2000+ Practice Book Of Engineering Aptitude , Genco,Transco And Discoms Practice Book : Ee , Ssc Junior Engineer Electrical Engineering Computer Based Online Exam Self Study Guide Cum Practice Work Book (English Medium) , Practice Sets Railway Recruitment Boards Junior Engineer (Electrical) Computer Based Test (Iind Stage) , Gateway To……..Gate (Electrical Engineering) , Practice Sets Electrical Engineering [Useful For Railway & Other Engineering (Diploma) Exams.] , Interview Questions With Solutions For Electrical Engineers (For Bhel, Ntpc, Cil, Dvc Etc.) , Objective Electrical Engineering [Railway & Others Engineering (Diploma) Competitive Exams] , A Handbook On Electricals [Railway & Others Engineering (Diploma) Competitive Exams] , Go To Guide For Ssc Junior Engineer Electrical Paper I Recruitment Exam With Previous Year Solved Papers 5Th Edition | 100% Detailed Solutions | For 2022 Je Exam , Gate Tutor Electrical Engineering Exam 2026 | With Solved Paper 2025-23 & 5 Mock Tests , Gate Engineering Mathematics Chapterwise Solved Papers (2025-2000) , Gate Chapterwise Previous Years Solved Papers 2025-2000 | Electrical Engineering , Nsqf (Level 4) Electrician Theory (I & Ii Year) | English , Nsqf (Level 4) Electrician Practical (I & Ii Year) | English , Nsqf (Level 4) Workshop Calculation & Science Electrician (I & Ii Year) | English Medium , Nsqf (Level 4) Engineering Drawing Electrician (I & Ii Year) | English Medium , Dgt Pattern Electrician — Bharat Skill Question Bank | 1St Year | Based On Nimi & Cbt Pattern | Hindi & English Medium , Dgt Pattern Electrician — Bharat Skill Question Bank | 2Nd Year | Based On Nimi & Cbt Pattern | Hindi & English Medium , Handbook Series Of Electrical Engineering , Ssc Junior Engineer (Cpwd/Mes) Electrical Engineering Paper 1 Cbt 2023 , Nda Na 22 Previous Years Solved Papers (From 2014 To April 2025) Chapterwise And Topicwise Pyqs , 28 Afcat Previous Years Solved Papers (2025 - 2011) For Flying, Technical & Ground Duty (Non-Technical) Branches For 2025-26 Exam | Previous Year Questions | Pyqs | Fully Solved , Ssb Interview Book 2025 - A Complete Guide For Defence Exams Nda, Cds, Afcat, Tes, Navy B.Tech, Ncc Entry, Ues, Tgc, Ta, Ssc (T) | All Interview Activities Covered , Ssb Interview Books Power Pack: 4 Essential Books For Defence Aspirants , Ssb Interview: The Complete Guide, Second Edition , Ssb Oir & Ppdt , Ssb Interview : Ppdt Narration Guide & Workbook | Personality Introspection Guide , Ssb Interview Workbook : Complete Practice Of Screening Tests, Psychology Tests, Gto, Personal Interview And Conference , Rrb-Je Special Practice Combo Set Of 4 Books For Electrical Engineering Exam , Electrical Engineering Combo Pack Mcq Smart Edition , 6500+ Mcqs: Electrical Engineering (English) , Iti Electrician Trade Book :- Theory + Objective , Basic Mathematics For Engineers (Engineering Reference Books) , Power Electronics (Engineering Reference Books) , Electrical Machines - Ii , Electrical Machines - I , Electromagnetic Field Theory , Microcontrollers (Engineering Reference Books) , Basic Electrical Engineering (Engineering Reference Books) , Digital Electronics (Engineering Reference Books) , Basic Electrical & Electronics Engineering (Engineering Reference Books) , Signals And Systems (Engineering Reference Books) , Electrical Circuit Analysis (Engineering Reference Books) , Measurements And Instrumentation (Engineering Reference Books) , Basic Electrical & Electronics Engineering (Engineering Reference Books) , Electric Circuits & Electron Devices (Engineering Reference Books) , Basic Electrical & Instrumentation Engineering (Engineering Reference Books) , Electrical Power Transmission & Distribution (Engineering Reference Book) , Protection And Switchgear (Engineering Reference Books) , Principles Of Electrical Engineering (Engineering Reference Books) , Electrical Drives And Actuators (Engineering Reference Books) , Sensor And Instrumentation (Engineering Reference Books) , Transformers And Generators (Engineering Reference Books) , Transmission And Distribution (Engineering Reference Books) , Iti Electrician Practical I & Ii Year English , Design With Pic Microcontrollers , Power System Optimization , Extra High Voltage Ac Transmission Engineering , Hvdc Power Transmission Systems , Non Conventional Energy Sources , Renewable Energy Sources And Emerging Technologies 2/E , Solar Photovoltaics: Fundamentals, Technologies And Applications 2/E , Wind Electrical Systems , Utilisation Of Elect Power , Circuit And Network Theory: For Gate, Psus And Es Examination , Analog Electronics: For Gate, Psus And Es Examination , Control Systems: For Gate, Psus And Es Examination , Microprocessors: For Gate, Psus And Es Examination => Limited
Contract Date: Nov 19, 2025 Contract Value : 10
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Sep 09, 2024 Contract Value : 1.07 Crore
Government Departments No of Bidders 3
Madhya Pradesh View Result →
44.
Heavy Industries and Public Enterprises #8122211 AOC
supply of E4253001 Numerical Relays CRP 01-SG4935107006- NUMERICAL MAIN-1 GENERATOR PROTECTION RELAY AS PER IT-01 OF ANN-1 , 02-SG4935107014-ACCESSORIES FOR SEF _and_ REF AS PER IT-02 OF ANN-1 , 03-SG4935107022- NUMERICAL MAIN-2 GENERATOR PROTECTION RELAY AS PER IT-03 OF ANN-1 , 04-SG4935107030-NUMERICAL TRANSFORMER DIFFERENTIAL _3 WDG_ PROTECTION RELAY AS PER IT-04 OF ANN-1 , 05-SG4935107049-NUMERICAL OVERALL DIFFERENTIAL PROTECTION RELAY AS PER IT-05 OF ANN-1 , 06-SG4935107057-NUMERICAL OVERCURRENT _and_ REF PROTECTION RELAY AS PER IT-06 OF ANN-1 , 07- SG4935107065-METROSIL AS PER IT-07 OF ANN-1 , 08- SG4935107073-STABILISING RESISTOR _0-5K_ AS PER IT-08 OF ANN-1 , 09-SG4935107081-ETHERNET SWITCH AS PER IT-09 OF ANN-1 , 10-SG4935117001-NUMERICAL MAIN-1 LINE DISTANCE PROTECTION RELAY _PROCESS BUS_ AS PER IT-10 OF ANN-1 , 11-SG4935117010-NUMERICAL MAIN-2 LINE DISTANCE PROTECTION RELAY _PROCESS BUS_ AS PER IT-11 OF ANN-1 , 12-SG4935117028-NUMERICAL MAIN-1 LINE DIFFERENTIAL PROTECTION RELAY _PROCESS BUS_ AS PER IT-12 OF ANN-1 , 13-SG4935117044-NUMERICAL MAIN-2 LINE DIFFERENTIAL PROTECTION RELAY _PROCESS BUS_ AS PER IT-13 OF ANN-1 , 14-SG4935117117-NUMERICAL TRANSFORMER DIFFERENTIAL _3 WDG_ PROTECTION RELAY _PROCESS BUS_ AS PER IT-14 OF ANN-1 , 15- SG4935117125-NUMERICAL OVERCURRENT _and_ REF PROTECTION RELAY _PROCESS BUS_ AS PER IT-15 OF ANN-1 , 16-SG4935117133-NUMERICAL ISLANDING RELAY _PROCESS BUS_ AS PER IT-16 OF ANN-1 , 17- SG4935117141-NUMERICAL LBB PROTECTION RELAY _PROCESS BUS_ AS PER IT-17 OF ANN-1 , 18 SG4935117150-NUMERICAL TEED PROTECTION RELAY _PROCESS BUS_ AS PER IT-18 OF ANN-1 , 19- SG4935117168-METROSIL AS PER IT-19 OF ANN-1. , 20- SG4935117176-STABILISING RESISTOR _0-5K_ AS PER IT-20 OF ANN-1 , 21-SG4935117184-NUMERICAL BUSBAR PROTECTION PROCESS BUS _NEW SWITCHYARD IN PRESENT SCOPE_ AS PER IT-21 OF ANN-1 UOM-set , 22- SG4935117192-BAY CONTROL UNIT _PROCESS BUS_ AS PER IT-22 OF ANN-1 , 23-SG4935117206-PANEL ALONG WITH MERGING UNIT _and_ SWITCHGEAR CONTROL UNIT _PROCESS BUS_ AS PER IT-23 OF ANN-1 UOM-set , 24- SG4935117214-ETHERNET SWITCH _PROCESS BUS_ AS PER IT-24 OF ANN-1 , 25-SG4935117222- GATEWAY_slash_NETWORKING PANEL AS PER IT-25 OF ANN1 , 26-SG4935117230-OWS _CCR_ AS PER IT-26 OF ANN-1 UOM-set , 27-SG4935117397-EWS _CER_plus_CRP_plus_CCR_ AS PER IT-27 OF ANN-1 UOM-set , 28-SG4935117249-LAPTOP _SCR_plus_EX_ AS PER IT-28 OF ANN-1 , 29-SG4935117400-A4 PRINTER _CER_plus_CRP_plus_CCR_ AS PER IT-29 OF ANN-1 , 30- SG4935117257-OWS _SCR_plus_EX_ AS PER IT-30 OF ANN-1 UOM-set , 31-SG4935117265-EWS _SCR_plus_EX_ AS PER IT31 OF ANN-1 UOM-set , 32-SG4935117273-A3 PRINTER _SCR_plus_EX_ AS PER IT-32 OF ANN-1 , 33-SG4935117281- A4 PRINTER _SCR_plus_EX_ AS PER IT-33 OF ANN-1 , 34- SG4935117370-DOT MATRIX PRINTER _SCR_plus_EX_ AS PER IT-34 OF ANN-1 , 35-SG4935117290-LAPTOP _SCR_plus_EX_ AS PER IT-35 OF ANN-1 , 36-SG4935117303- 80 inch REAR PROJECTION LVS AS PER IT-36 OF ANN-1 UOMset , 37-SG4935117311-INVERTER AS PER IT-37 OF ANN-1 UOM-set , 38-SG4935117320-NETWORK FIREWALL AS PER IT-38 OF ANN-1 UOM-set , 39-SG4935114002-FO CABLE _IN MTRS_ AS PER IT-39 OF ANN-1 UOM-meters , 40- SG4935117338-CONTROL ROOM FURNITURE AS PER IT-40 OF ANN-1 UOM-set , 41-SG4935117346-SAS SPARES AS PER IT-41 OF ANN-1 UOM-set , 42-SG4935117354-TRAINING AS PER IT-42 OF ANN-1 UOM-set , 43-SG4935117389-AMC AS PER IT-43 OF ANN-1 UOM-set
Contract Date: Ref. Documents Contract Value : 12.99 Crore
Boards / Undertakings / PSU No of Bidders 2
Madhya Pradesh View Result →
45.
Defence #8113046 AOC
Tender For Provision Of Otm Accommodation For Af Station Adampur.; 1 SCHEDULE `A PART - I (Building / Structure Works) is not prepriced by MES and prepriced rates indicates0.00 under column 5 signifies this fact only. 2 Construction of TECH LAB including VIFT & Traverse wall complete in all respect all asshown on drawings & as specifiedin tender documents. Note :- 11. EOT crane including gantry girders as shown on drawing shall be measured and paid separately under respective item of BOQ. However cost of RCC bracket for gantry girder shall be deemed to be included in lumpsum quoted rate. 2.PCC Road/Hard standing shown on drwaing in front side shall be measured & paid separately under respective item of BOQ under respective schedule for Road and Culvert. However plateform/Ramp shown in front shall be deemed to be included in lumpsum quoted rate.3. Sliding roller shown at entry gate of preservation/ depreservatio room shall be measured and paid separately under respective item of BOQ. 4. Fire fighting Board and Fire Point shall be measured and paid separately under respective item of BOQ. 3 Construction of Adm Block Building complete as per specificationsand asshown on drawings complete. 4 Construction ofGround Equipment Bay Building complete as per specificationand asshown on drawings complete. 5 Construction of ASV BAY with Apron complete as per specificationand asshown on drawings complete. 6 Construction ofMT Section Building complete as per specificationand asshown on drawings complete. 7 Construction of POL STORE Building complete as per specificationand asshown on drawings complete. 8 Construction of GUARD REST ROOM Building complete as per specificationand asshown on drawings complete. 9 Construction of RCC WATCH TOWER Type -DDOUBLE STOREY all as per specificationand asshown on drawings complete. 10 Construction of AC Plant Room & Sub Station Building including AHU Building all as per specificationand asshown on drawings complete. 11 Construction of Static Water Tank (SWT) 225000 ltr capacity all as per specificationand asshown on drawings complete. 12 Construction of RCC overhead reservoir ofCAPACITY 15000 Glns and 21M Staging Height all as per specificationand asshown on drawings complete. 13 Construction ofRCC Septic Tank for 50 users, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls, base slab, baffale walls and RCC slab including beams etc with vent shaft , manhole opeing with cover connections etc, complete with effective depth 1.5 meter and overall depth 3 mtrcomplete all as specified and as shown on drawing No CEAF/STD/ST-118/22 Sheet 1/3 to 3/3 14 Construction ofRCC Septic Tank for 25 users, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls, base slab, baffale walls and RCC slab including beams etc with vent shaft , manhole opeing with cover connections etc, complete with effective depth 1.5 meter and overall depth 3 mtrcomplete all as specified and as sown on drawing No CEAF/STD/ST-118/22 Sheet 1/3 to 3/3 15 Construction of Soakage well excavation, in any type of soil , foundation, in PCC 1:3:6, walls of hony combed masoonary with top ring of M-25 concrete including interceptiing chamber and screen chamber made of brick masoanry in CM, RCC cover slab in M-25/SFRC cover, inter connecting pipes of RCC /DWC complete filled with brick bats of size 2.40m dia x 3.00m effective depth complete all as per Drg No.CEAF/STD-301/90 sheet 1/4 to 4/4 and as specified. 16 Construction of Soakage well excavation, in any type of soil , foundation, in PCC 1:3:6, walls of hony combed masoonary with top ring of M-25 concrete including interceptiing chamber and screen chamber made of brick masoanry in CM, RCC cover slab in M-25/SFRC cover, inter connecting pipes of RCC /DWC complete filled with brick bats of size 1.80m dia x 3.00m effective depth complete all as per Drg No.CEAF/STD-301/90 sheet 1/4 to 4/4 and as specified. 17 M&L for Sliding Rollers 1mtr wide and 8.15mtr long having frame made out of MS Angle iron 75mmx75mmx8mm, rollers made out of GI pipe 50mm heavy grade fixed to frame@ 100mm c/c alongwith MS bearings and axle rod 12mm to 16mm passing through both sides bearings and fixed with frame for smooth sliding of loads complete all as specified and as directed. 18 NOTE: Schedule ‘A’ Part IIto XIV under Ser No 2.01 to 2.13 are Prepriced by MES. 19 Lump sum price worked out by the Contractor for “ SITE DVELOPMENT, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part II 20 Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’Part III 21 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY as listed in Schedule ‘A’Part IV 22 Lump sum price worked out by the Contractor for SEWAGE DISPOSAL” as listed in Schedule ‘A’Part V 23 Lump sum price worked out by the Contractor for “AREA DRAINAGE as listed in Schedule ‘A’Part VI 24 Lump sum price worked out by the Contractor for “ROAD, PATH AND CULVERT ” as listed in Schedule ‘A’Part- VII 25 Lump sum price worked out by the Contractor for “FENCING AND GATE ” as listed in Schedule ‘A’Part- VIII 26 Lump sum price worked out by the Contractor for“EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’Part - IX 27 Lump sum price worked out by the Contractor for“EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’Part - X 28 Lump sum price worked out by the Contractor for“LIGHTENING PROTECTION” as listed in Schedule ‘A’Part - XI 29 Lump sum price worked out by the Contractor for“REFRIGERATION” as listed in Schedule ‘A’Part - XII 30 Lump sum price worked out by the Contractor for“EOT CRANE” as listed in Schedule ‘A’Part - XIII 31 Lump sum price worked out by the Contractor for DEMOLITION AND DISMANTLING” as listed in Schedule ‘A’Part XIV 32 SCHEDULE `A PART - XV MISC ITEMS (B/R & E/M)is not prepriced by MES and prepriced rates indicate 0.00 under column 5 signifie this fact only. 33 MISC B/R WORKS - ROAD HARDSTANDING AND CULVERT, FENCING ETC (Rate against each item to be quoted by bidder ) 34 M&L for 150 mm thick GSBC (Granular sub base concrete) grading I as per table 400-1 morth specifications and mixed with 35% coarse graded crushed stone agg by providing close graded material mixing by any means as per site conditions, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne capacity and maintaining the required density, grading and moisture content as per MORTH specifications, compacted stabilised sub base of 98% MDD to achieve saturated stabilised K Valve of min 4.0 Kg/sqcm complete all as specified and as directed 35 M & L for painting 2mm thick with thermoplast fluorescent paint of colour white or golden yellow or any other shade conforming to BS standard 3262 with 20% glass beads (inter mixed) applied hot with automatic (commercial) machine drive in strips after preparation of surfaces as per manufacturers instructions & according to the specifications laid down by IRC & MOST (Ministry Of Surface Transport), Specifications 2001 (4th revision), making lines, broken lines/dashes, arrows etc. on roads and other like surfacesexceeding 10 cm but not exceeding 2cm In width or girth, complete all as specified and as directed. 36 S & F solar delinator, with four ultra bright flashing LEDs, polycarbonate and toughened aluminium alloy body, fitted on MS pipe 50mm dia (apprcx 1.00 m long ), powder coated, anti rust, fixed in position in PCC 1:2:4 block 20cmx20cmx30cm with necessary fixing arrangement as per manufacturers instructionscomplete all as specified and as directed. 37 S & Fsolar stud 125mmx125mmx25mm aluminium alloy shell with rechargable battery, LED 03 Nos each side (total 06 Nos), flash rate and colour as approved by GE, fixed in position with necessary fixing arrangements as per manufacturers instructions,complete all as specified and as directed. 38 M&L for600 mm NP2 RCC Hume pipe under ground duct from ASV Bay to Test Lab as shown on site plan & Drg No CEAF/ADM/SK-05/2024 sheet No 1R/1 and CEAF/ADM/WD/ST-333-01/2024 sheet No 03R/5 39 Supply and fixing concertina coil of 600mm dia complete all as specified and as directed. 40 M&L for construction of steel gate 5.50 m wide and 2.75m high from road level alongwith wicket gate for security fencing including PCC MS work, excavation and earthwork in any type of soil, RCC pillars, painting of MS surfaces with two coats of synthetic enamel paint over a coat of red oxide primer, distempering of RCC pillars with exterior emulsion paint over primeretc. complete all as specified and as shown on drawings No CEAF/STD-151-2002 sheet 1/2 to 2/2 dated 02/11/2002. 41 MISC INT/EXT ELECTRIFICATION (Rate against each itemto be quoted by the bidder) 42 Construction of Wall Mounted Fire Points with 06 buckets and 06 fire extinguiser each complete in all respect shown on drawing No CEAF/STD/190/2014 Sheet 1/1 & as specifiedin tender documents. 43 S&F Fire symbol board of size 1200mm x 1650mm made out ofMS Sheet 1.60mm thick with frame made out of angle iron 50mm x 50mm x 6mm, embeded in PCC block (1:2:4) type B-1 of size 450mmx450mmx500mm, painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. 44 S&F LED bulb, 09 watt, 230 volts retrofit type cornp!ete all as complete all as specified and as directed. 45 Supply & Fixing LED security light 15 watt, input 110 to 220 volts as per IP 65 luminaries comprising of rectangular shape, high pressure die cast aluminium housing, with weather proof gaskets for lamp and driver compartment with GI pipe 25 mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and as directed. 46 S&F MCB SP 6 to 32 Amps, C curve type 10 KA breaking capacity, 240 Volts completeall as specified and as directed. 47 S&F MCB SPN 40 Amps, C curve type 10 KA breaking capacity, 240 Volts completeall as specified and as directed. 48 S&F MCB TPN 63 Amps, C curve type 10 KA breaking capacity, 415 Volts completeall as specified and as directed. 49 Supply andfixVoilagestabilizer forautomatic operation, singlephase manualy air cooled indoor type & designed for input variation belween 170 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA, complete all as specified and as directed. 50 Supply andfixVoilagestabilizer forautomatic operation, singlephase manualy air cooled indoor type & designed for input variation belween 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and as directed. 51 S&F of vertical type load line Distribution Board, double door, 8 way, AC, 3 phase, 415 Volts, TPN bus bar 200 Amps rating and earth bar & din rail including MCCB 125 Amp,16 KA 4 Pole as incomer Distribution board suitable for three / single phase MCBs outgoing complete all as specified and as directed. 52 S&F of vertical type load line Distribution Board, double door, 8 way, AC, 3 phase, 415 Volts, TPN bus bar 200 Amps rating and earth bar & din rail including MCCB 63 Amp,16 KA 4 Pole as incomer Distribution board suitable for three / single phase MCBs outgoing complete all as specified and as directed. 53 S&F of vertical type load line Distribution Board, double door, 12 way, AC, 3 phase, 415 Volts, TPN bus bar 200 Amps rating and earth bar & din rail including MCCB 100 Amp, 25 KA 4 Pole as incomer Distribution board suitable for three / single phase MCBs outgoing complete all as specified and as directed. 54 S&F of vertical type load line Distribution Board, double door, 12 way, AC, 3 phase, 415 Volts, TPN bus bar 400 Amps rating and earth bar & din rail including MCCB 250 Amp, 25 KA 4 Pole as incomer Distribution board suitable for three / single phase MCCBs including outgoing as MCCB TP 125 Amps 25 KA -01 No, MCCB TP 100 Amps 25 KA -01 No, and MCCB TP 63 Amps 16 KA -01 No complete all as specified and as directed. 55 S&F MCB TP 5-32 Amps, C curve type 10 KA breaking capacity ,415 voltscomplete all as specified and as directed. 56 S&FThreepole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 20 amps capacity completeall as specified and as directed. 57 M & L for sub main wiring with Three single core FRLSH, PVC insulated, multistranded, unsheathed copper conductor cable with size 04 Sqmm and drawing through& including Non metallic PVC rigid conduit concealed in wall including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed multi stranded copper conductor cable with suitable size of PVC Conduit as per IS mm and connected to earth dolly including connecting to main boardcompleteall as specified and as directed. (Note :- Three runs of Cable, One run of conduit and one run of earth wire shall be measured and one unit). 58 M&L for flame proof,zone I & II, Gas Group II A/ II B, weather proof submain wiring with four runsusing approved colour coding as per IS, zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 6.0 Sqmm (nominal area) single core 1100 voltsand one run earth wire of 6.0 Sqmm in and including ERW stove enamelled black rigid conduit of required size but not less than 25mm dia, flame proof conduit accessories such as tee, bend, elbow, junction box completeall as specified and as directed. (Note :- Four runs of Cable, One run of MS conduit and one run of earth wire shall be measured and one unit). 59 M&L for flame proof,zone I & II, Gas Group II A/ II B, weather proof submain wiring with four runsusing approved colour coding as per IS, zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area) single core 1100 voltsand one run earth wire of 4.0 Sqmm in and including ERW stove enamelled black rigid conduit of required size but not less than 25mm dia, flame proof conduit accessories such as tee, bend, elbow, junction boxcompleteall as specified and as directed. (Note :- Four runs of Cable, One run of conduit and one run of earth wire shall be measured and one unit). 60 M&L for flame proof,zone I & II, Gas Group II A/ II B, weather proof submain wiring with four runsusing approved colour coding as per IS, zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 2.5 Sqmm (nominal area) single core 1100 voltsand one run earth wire of 2.5 Sqmm in and including ERW stove enamelled black rigid conduitof required size but not less than 20mm dia, heavy duty,flame proof conduit accessories such as tee, bend, elbow, junction boxcompleteall as specified and as directed. (Note :- Four runs of Cable, One run of conduit and one run of earth wire shall be measured and one unit). 61 M&L flame proof,zone I & II, Gas Group II A/ II B, weather proof point wiring for one light/fan/indepedant socket point controlled by one switch using approved colour coding as per IS with zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enamelled black rigid conduitof required size but not less than 20mm dia,heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required includingPVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductorcompleteall as specified and as directed. 62 M&Lflame proof,zone I & II, Gas Group II A/ II B,weather proof point wiring for one socket point controlled by one switch using approved colour coding as per IS with zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enamelled condiuit heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required includingPVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor completeall as specified and as directed. 63 S&F switch flame proof,zone I & II, Gas Group II A/ II B,weather proof rotary type with termination box in LM6 16A single pole 250 V complete all as specified and directecompleteall as specified and as directed. 64 Supply and fixing flame proof,zone I & II, Gas Group II A/ II B, weather proof switch socket and plug combined in LM6 16A, 240 V, 2 pin and earth plug fully interlocked suitable for installation in hazardous as per IS-2147/62 aluminium alloy/cast iron neoprene gasket degree of protection IP 65 certified by CMRI complete all as specified and directedcompleteall as specified and as directed. 65 Supply and fixing flame proof,zone I & II, Gas Group II A/ II B, weather proof switch socket and plug combined in LM6 25A, 240 V, 2 pin and earth plug fully interlocked suitable for installation in hazardous as per IS-2147/62 aluminium alloy/cast iron neoprene gasket degree of protection IP 65 certified by CMRIcompleteall as specified and as directed. 66 Supply and fixing LED wall light fitting 1x16 watts,flame proof,CMRI certified recommended for gas/vapour group ofII A/ II B,Zone 1&2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture driver,holders,connectors etc. complete with all accessories prewired and incl connected up with three core flexible copper conductor cablecompleteall as specified and as directed. 67 Supply and fixing LED Suspended light fitting 1x16 watts,flame proof,CMRI certified recommended for gas/vapour group ofII A/ II B,Zone 1&2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture driver,holders,connectors etc. complete with all accessories prewired and incl connected up with three core flexible copper conductor cablecompleteall as specified and as directed. 68 Supply and fixing flame proof,zone I & II, Gas Group II A/ II B, weather proof switch socket and plug combined in LM6 16A, 415V,3 Phase, 3 pin incl plug fully interlocked suitable for installation in hazardous as per IS-2147/62 aluminium alloy/cast iron neoprene gasket degree of protection IP 65 certified by CMRIcompleteall as specified and as directed. 69 Supply and fixing flame proof,zone I & II, Gas Group II A/ II B, weather proof switch socket and plug combined in LM6 25A, 415V,3 Phase, 3 pin incl plug fully interlocked suitable for installation in hazardous as per IS-2147/62 aluminium alloy/cast iron neoprene gasket degree of protection IP 65 certified by CMRIcompleteall as specified and as directed. 70 Supply and fixing flame proof,zone I & II, Gas Group II A/ II B, weather proof DB TBN 415 volts 8 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable enries with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP 65 suitable for MCCB TPN 160 Amps -1 Nos (incoming) and MCB TPN 32 Amps-03 Nos (out going) MCB TPN 63 Amps-01 Nos (out going), complete all as specified and directed. 71 Supply and fixing flame proof,zone I & II, Gas Group II A/ II B, weather proof DB TBN 230 volts 8 way with busbar in cast aluminium LM-6 enclosure operated externally spring type knob complete with suitable incoming and outgoing cable enries with cable glands suitable for hazardous area and confirming to IS-2147/62 neoprene gasket degree of protection IP 65 suitable for MCB TPN 40 Amps -1 Nos (incoming) and MCB SP 6-10 Amps-06 Nos (out going) MCB TPN 63 Amps-01 Nos (out going), complete all as specified and directed. 72 Supply and fixing flame proof ceiling fan of size 1200 mm sweep complete with regulator, electric driven suitable for operation on single phase, 230 V AC complete all as specified and directed. 73 EXTERNAL ELECTRIFICATION 74 Supply, Installation, commissioning and testing oftransformer (step down ) 11 KV / 433 Volts (as per IS 1180 Part-I 2014 and BEE certified Level 2)Outdoor type copper wound suitable for AC. three phase, 4 wire. 50 Hz system of capacity 250 KVA , oil immersed having Vector group DYN 11 naturally cooled type complete with and including provn of first filling of transformer oil, Delta connection on HT side, star connection on LT side, manually operated. off-load tap changer on HT side to varysecondary voltage to+7.5% in steps of 2.5% each, cable end box at LT side. LT side cable box shall be fitted with suitable size of cable glands for making connection for all the accessories and the under mentioned fittings, all as specified and directed by GE (A) Rating plate and terminal making plate.( B). two earthing terminals for body earthing and two additional for neutral brought out on a bushing (C) Lifting lugs (D) Drain valve with plug or cover plate (E) Dehydrating breather (F) Oil level indicator with minimum and maximum marking (G) Cooling Radiator 75 (H) Thermometer pocket (I) Conservater (J) Oil filling hole with cover (K) Thermometer 100mm dia/stem type with metal guard having maximum temperature indication with resetting as directed by the GE (A) Any other fittings as recommended by the manufacturer for efficient functioning of the transformer.Note :- (i) The fitting & accessories of the transformers shall be conforming to IS 3639 :1996(ii) The transformer shall be installed on a plateform / foundation as per manufacturers designand cost of the same shall be deemed to be included in unit rate (iii) The transformer shall be tested as per IS for all routine tests. in the factory premises, in the presence of Rep of Acepting Office (who will be detailed by the Accepting Officer on the receipt of request from the contractor before dispatch of the transformer) 76 Supply Installing testing and commissioning of HT 11 KV panel 3 phase 50 Hz 3 wire totally enclosed meta! clad re-wire extendable type indoor floor mounted horizontal draw out horizontal isolation type Vaccume Circuit Breaker (VCB) of capacity 400 Amps motor operated spring charged having rupturing capacity of 250 MVA and consists cf the following specifications. (a) . 400 Amps continuous rated electrolytic copper bus bars, droppers and bus bars should be insulaied with full system voltage sleeves of approved make (b) Truck /Trolly mounted vaccume curcuit breaker as per IEC 62271-200 VCB should have three non resin encapsulated vaccum bottle of approved manufacturer.( c) Motorized spring charging mechanism with integral spring crarging handle for manual spring charge (d) NO lnterpanel epoxy barriers required to restrict arc propagation from one panel io other (e). Cast resin current transformer 11 KV 100-50/5-5A. Cl 1 0 and 5P10, 15VA (f) Cast resin potential transformer 11KV/V3/110V/110VA: C! 1, 0, Cl 3P and HT fuse at the primary end and.04 Pole MCB at the secondry end of the PT. 77 (g). Accessories like local remote switch. breaker control switch (T-N-C), space heater with thermostat. DC & AC control circuit through MCB, indicating lamps for RYB, spring charge DC supply healthy, breaker ON/OFF breaker in SERVICE/TEST as per manufacturer (h) Multi function meter with port Medel no EM6400 cf CONSERV make or equivalent L&T make(j) Comprehensive numerical protection relay as per !EC 61850 compatible for directional and non directional O/C, E/F, U/V, O/V protection. Breaker should Have following additional facilitiesa) Trip circuit supervision b) Disturbance recorderc).Eventlog with date and timed) Measurement and control feature e)Panel should also rave additional facility like a) Intermitrant rated closing and tripping coil b) Fully internal arc type tested (25 KA for 1 sec as per latest IEC- 62271-200.c). Vaccum bottles should be epoxy encapsulated. d). Racking in/out manual closrng/tripping of CB with compartment door closed. Note :- Panel, breaker relay & vaccum interruptor shall be same make.NOTES:- - (i) Drawing for HT Panel shall be approved by GE before placement of order (ii) Cost of any addition/Altn requiree for fixing of Breakeris included in overall cost quoted by contractor(iii) The rate quoted shall be deemed to be included in the cost of provn of 24 Volt DC Power Pack for the relays. (iv) any type of civil work required is included in overall cost quoted by contractor. 78 Supply installation testing and commissioning of main LT panel lndoor type IP-42 approvedrnake powder coated suitable for 3 Phase 415 volt, dust, weather and vermin proof made out 2mm thick CRCA sheet aluminium bus bar 500 Amp TPN incl provision of cable entries with glands locking arrangementsandangle iron frame and legs 90cm long using 60x60x6mm size MS angle iron fixed in floor in PCC 1:4:8 type D2, base of appropriate size including necessary excavation ear!h work complete with following arrangement(a) INCOMING:- (i) MCCB 315 Amp.4 pole 5OKA- 01 No(ii) Volt Meter Digital type with selector switch 0-500 Volt(iii) Ampere Meter Digital type with selector switch 0-350 A(iv) RYB Phase indicating LED lamp- 03 Nos(b) OUTGOING .- (i) MCCB 4 pole 250 Amp 25 KA - 01No (ii) MCCB 4 pole 200 Amp 16 KA - 01No (iii) MCCB 4 pole 40 Amp 16 KA - 01No 79 Supply installation testing and commissioning of main LT panel outdoor type CPRI approved powder coated suitable for 3 Phase 415 voit dust weather and vermin proof made out of 3.15mm thick CRCA sheet aluminium bus bar 400 Amp TPN incl provision of cable entries with glands locking arrangementsandangle iron frame and legs 90cm long using 60x60x6mm size MS angle iron fixed in floor in PCC 1:4:8 type D2, base of appropriate size including necessary excavation ear!h work complete with following arrangement(a) INCOMING:-(i) MCCB 4 pole 250 Amp 35 KA - 01No(ii) Volt Meter Digita! type with selector switch 0-500 Volt(iii) Ampere Meter Digital type with selector switch 0-300 A(iv) RYB Phase indicating LED lamp- 03 Nos(b) OUTGOING .- (i) MCCB 4 pole 200 Amp 25 KA - 01No (ii) MCCB 4 pole 63 Amp 16 KA - 02No 80 Material and labour for Boring holes under road / pavement/ hard standing by trenchless technology using ultrasound technique and necessary machine for inserting and including 80mm/100mm dia bore double wall hose pipe compleie all as specified and as directed. 81 Supply and fix pole mounted terminal box of size 310x210x120mm(In side dimesion) including MCB SP 6 Amps, 4 Nos aluminium bus bar of 25mmx3mm thick fixed on porcelain post insulators with hinged cover and locking arrangement fixed to electric pole by means of MS flat iron 25mm x 6mm bolts and nuts complete all as specified and as directed. (Terminal box shall be IP 66 protection). 82 Supply and fixing roadway LED light in versatile pressure die cast aluminium road way luminare with high power LED with IP-66 Protection of 120 Watt capacity including fixing arrangemen clamps, bolts, nuts and brackets etc complete all as specified and as directed. 83 Supply and laying 2.5 Sqmm 3 core PVC unsheathed copper conductor PVC insulated cable drawn along steel pole for connection to streetlight fittings complete all as specified and as directed 84 Supply and fixing security LED light in versatile pressure die cast aluminium road way luminare with high power LED with IP-66 Protection of 45 Watt capacity including fixing arrangements clamps, bolts, nuts and brackets etc complete all as specified and as directed. 85 Supply and fixing. cable route marker for HT cable duly engraved (HT 11 KV cable) on 150mm dia MS round plate, duly painted with brown colour paint and fixed on MS angle of size 40mmx40mmx5mm with nuts and bolts and embedded in PCC (1:2:4) concrete block of size 230mm x 230mmx150mm complete all as specified and as directed. 86 Supply and fix LED post top lantern 25 W input voltage 230 volt 50 Hz with die cast aluminium spigot & prismatic diffuser, IP 66 protection class including fixing arrangement like suitable clamps nut bolts and washers and connecting up with suitable size of copper conductor cable complete all as specified and as directed. 87 STANDBY POWER SUPPLY 88 Supply, installation, testing & commissioningof factoryassembled & coupled silent Diesel engine generating set. AC, complete to give an out put of 250 KVA (200KW) at 415 volt, 50 cycle per second 3 phase, 4 wire supply with power factor 0.8 diesel engine as per IS 10001/10002 and alternatoras per IS 13364 and dully mounted on common base, frame complete with relay panel and switch gear for automatic starting on main failure control panel along with by pass arrangement with cabling system and including having meter and sound proof canopy as per CPCB norm and foundation work, fuel tank including accessories and components as specified below :-(a) Diesel driven Engine 250 KVA with multi cylinder, vertical, 4 stroke cycle,water cooled, diesel engine of approved make suitable to develop matching at 1500 RPM as per IS- 10001/10002. capable of taking10% over load for one hour in any12hrsrunning complete with and including following accessories :- 89 (i) Heavy duty fly wheel and fly wheel housing complete with starting gear ring and to suit flexible coupling duly covered with mud guard(ii) Air cleaner(iii) radiator with cooling fan and guage(iv) Fuel injector pump(v) water temperature guage(vi) Fuel filter(vii) Microprocessor automatic controlled governor(viii) Complete set of batteries with lead & lugs asrecommendedbymanufacturers(ix) Lubricant oil cooler(x) Lubricant oil pump(xi) Lubricant oil filter(xii) Oil pressure guage(xiii) Any other parts as prescribed by manufacturer for making it functional.(xiv) Dynamo of suitable capacity(xv) MS channel fabricated frame rigidly welded suitable for having the diesel engine and alternator and anti vibration pads(xvi) Coupling guard 90 (xvii) Exhaust pipe including residential silencer and necessary insulation.(xviii) Fuel tank for 10 hrs requirementat full load with inlet and outlet connection, filling cap,drain valve, air vent. (xix) Multi Function Meter(xx) Self starter of suitable size :(xxi) Integral-acoustic enclosure to control noise limit as specified by central pollution board & manufactured by company or authorised OEM of company. (xxii) Battery 12 volt as per OEM(d) Alternator 250 KVA at 0.8 PF vvith self excited self regulated 3Phase, 50 Hz 415 volts, 1500 RPM 4 wire alternator.screen protected drip proof free frorn commutation problem continuous rating as per IS-13364 complete with microroprocessor controlled automatic voltage regulator output voltage regulated between 1% of set volts from NO load to full load. (xxiii) DG Set control Panel with multifunction / digital meter for monitoring Engine RPM, Engine Temp, Oil Pressure, Hrs Run, KW, KWH, KVA, PF, Line Load 3Φ line to line, load line (RYB) to Neutral, voltage 3Φ line to line voltage 1Φ line (RYB) to Neutral DG set Panel should have the safety, indicator and audio alarm for High / Low oil pressure, High engine temperature, Engine over speed, low frequency, low fuel level. 91 (c)PCC foundation of suIiable size as recommened by OEM.Note :- Necessary excavation & earth work, sand cushioning grouting foundation etc deemed to be included In the unit rate(d) Manufacturers maintenance & operation manual of Gen set-01 set to be supplied(e) AMF panel factory made cubical automatic mains failure panel suitable for 250 KVA DG set made of 2mm thick CRCA sheet powder coated paintingcomplete with having relay panel and switch gear for automatic startng on main failurecontrol panel along with by pass arrangement with cabling system and suitable rated bus internal wiringprovn for connection ofXLPE, UG cable as IncomIng and outgoing angle iron base with & including following accessoriesti) Mas!er switch fer automanual / reset / off- 01 92 (ii) Volt meter dIgital type .(iii) Ammeter digital type with CTs -01 No(iv) Frequency meter digital type-01 No(v)Set of relays and conectors with and including incoming and out going 02 Nos MCCB 400Amps 4 pole 50 KA adjustable type movable thermostate for automatic start and automaticshutdownDG set - 01 (f) Push button start, stop and reset-01 No(g) Set of lamp for indicating load on set, low oil pressure, high cylender temperature load on mains sets fails to start.(h) Bty charger with suitable wiring and Bty charging indicator, DC volt meter 93 LIGHTENING PROTECCTION 94 M&L for copper round block size of 25mm dia x 50mm long having out side thread at one end to be fixed on the top of GI socket & inner thread 12mm for air termination, suitable arrangement for fixing the copper strip complete all as specified and as directed by Engr-in-Charge. 95 Supplyandfjxingcopperstaticdischarge plateconnectedtocommonearth complete all as speccified 30 cm x 30 cm including human body voltage check meter connected to common earth complete all as specified and as directed. 96 MISC EXTERNALWATER SUPPLY (Rate against each itemto be quoted by the bidder) 97 Supply , laying, testing and jointing, Ductile iron pipe of size 100 mm bore ISI mark class K 9, with flanged ends type, centrifugally cast, in any length,laid in trenches / path / duct / road/ wall etc including fixingwith connectedCl/DI/GIfittingaccessories and along with existing branch pipeline connections and its fitting worketc complete all as specified and as directed. Note- (Earthwork, fitting and joints shall be measured and paid for separately under respective items) 98 Supply , laying, testing and jointing, Ductile iron pipe of size 150 mm bore ISI mark class K 9, with flanged ends type, centrifugally cast, in any length,laid in trenches / path / duct / road/ wall etc including fixingwith connectedCl/DI/GIfittingaccessories and along with existing branch pipeline connections and its fitting worketc complete all as specified and as directed. Note- (Earthwork, fitting and joints shall be measured and paid for separately under respective items) 99 Supply , laying, testing and jointing, Ductile iron pipe of size 150 mm bore ISi mark class K 9, with spigot and socketed ends,centrifugally cast, conforming to ISI mark including titen joints, laid in trenches / path / duct / road/ wall etc including fixingwith connectedCl/DI/GIfittingaccessories and along with existing branch pipeline connections and its fitting worketc complete all as specified and as directed. Note- (Earthwork & fittingshall be measured and paid for separately under respective items) 100 Supply and fixing in replacernent, of cast iron air release ball valve with having double chamber ball with gun metal working parts for air outlet system including duly fitted with suitable size of GI prpe attachment system of size upto 50 mm dia bore all as per existing sample / model complete inciuding providing of mild steel flange with rubber flange seat and nut bolt & fittings complete all as specified and as directed. 101 Supply, fixed and Jointing in position DI fittings suilable for socketed or flanged type pipe line system any type any size such as bends tapers, Tee pieces (single & double branch) any type and any angle/radius and straight connecting pieces etc, fittings duly fixed and laid in trenches or on surface, complete all as specified and as directed Note : Earthwork and Joints shall be measured and paid separately. 102 M&L for Construction ofbrick masonry valve pit chamber ofinternal size 900mmx900mmx1050mm with one brick thick brick masonary wall in cement mortor(1:4),PCC foundation 10cm thick (1:4:8) type D2 with rendering 15 mm thick internally and top surface,MS frame of angle iron 40x40x6mm and 3mm thick MS sheet cover with locking arrangement, hold fast, hinges including painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and necessory excavation and earth work including dismantling of existing complete all as specified and as directed. 103 MISC AIR CONDITIONING AND REFRIGERATION (DESIGN AND BUILT BY THE CONTRACTOR) (Lump sum to be quoted by the bidder) 104 Design, Supply, Installation, Testing & Commissioning of water Cooled lnvertor scroll type Chilled water Central AC Plant of suitable capacity but mninimum 100 TR (2 x50 TR working and1x50 TRstandby) complete for entire test lab including preservation / de-preservation area.The bidder shall submit complete design of central AC plant along with heat load calculation capacity of pumps / motors, size of pipe, size of AC duct capacity of HWG, humidifire, cooling tower, AHU, expansion tank, LT panel, control cable, LT switchgear etc (alongwith technical data sheet and make) duly vetted by IIT/NIT for approval of accepting officer (through proper channel) before commencement of AC work, to achive desired· condition as per Annexure A of tender documents (duly signed by GE and users)and comprising of the following all as specified below and as directed. Note : Rates for Srl item No. 7.01 to Ser item No 7.94 of BOQ shall be included in Quoted rates. 105 Note :- (a) Contractor/ Bidderwill be responsiblefor performance guarantee of complete AC Plant to achieve the inside design conditions round the clock throughout the year with overall COP of the system not less than 3.(b) Rates quoted by the contractor shall include cost of labour, material, scaffolding, finishing as required with tools, plants.cartage, lift, taxes, tollage, octroi, royalties etc. All work shall be executed as per approved drawings . All materials shall be duly approved by GE before incorporation in the actual work. The plant shall interalia comprise the following :- 106 EQUIPMENT :- Water Cooled Chilling Machines Supply, Installation, Testing & Commissioning of 2 x50TR working and 1x50TR stand by water cooled Inverter scroll Chilling Machines fitted with hermetically sealed lnvertor scroll compressors, multi/single circuit chiller, water cooled shell & tube condenser, Microprocessor basedBMSCompitablecontrolpanel,suitableforR-407C/R-410aRefrigerant, Shell & Tube Insulated Evaporator, Expansion tank of suitable capacity Control Mechanism of actual Cooling capacity . 107 Scope of Supply(a) 3 No scroll compressor hermetic type complete with automatic capacity control, safety switches, forced feed lubrication system etc. as per specification. (b) 3 No:- Suitable capacity squirell cage induction motor with class F insulation suitable for operation on 415 volts, 50Hz, 3 ph, A.C. supply (c) 3 No. Microprocessor based starter suitable for compressor motor complete with ammeter & CTs, over load protection, under voltage protection, protection against phase reversal & independent single phase preventers etc. complete as required. 108 (d) 3 Set - Lubrication device consisting of automatic electric oil pump, oil cooler, oil strainer, automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per specifications.(e) 3 Set. - Matching Water Cooled condenser having Copper tube with Mechanically bonded aluminum fins.(f) 3 No. - Matching chiller for Chiller units.(g) 3 Lot- Refrigerant piping fittings, valves and accessories to interconnect compressor, condenser, chiller and expansion valve. 109 (h) 3 Set- Microprocessor based control panel complete with all safeties, controls and Touch screen display as per specifications.(i) 3 Lot- Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications.(j) 3 Lot- Suction line and chiller insulation with minimum 19mm thick polyvinyl nitril rubber insulation complete as required.(k) 3 Lot - MS Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti vibration pads/springs. 110 (I) 3 Lot- Initial/ first charge of refrigerant gas and compressor oil.(m) 3 Lot- RCC foundation for the chillers units as per manufacturers instruction with anti vibration pads complete.(o) Minimum flow rate for chiller - 27.59 CMH.(p) Minimum flow rate for condenser - 34.48 CMHNote:- (a) Next higher capacity of chiller machine may be supplied with out any extra cost to Govt. in case non availability of capacity as specified. 111 Supply, installation, testing and· commissioning of Automatic Condenser Tube Cleaning System complete with Control panel, Ball catcher, Pump, Pressure Gauge, LED indicators (1 control panel skid x 3 Nos Ball Catcher/ Ball Trap unit). The system should capable to accomodate three chillers from single skid/ system. The quoted price shall be inclusive of PLC programmable control box for auto operation of the system according to a pre-programmed logic. 112 Centrifugal mono block type chilled water pump set of suitable capacity (as per design) capable of delivering min. 125 USGPM of water each comprising of the following and complete all as : specified and as directed.(a) 3 Nos.- mono block type end suction pump with bronzeimpeller, SS Shaft, Cl body and mechanical seal with all accessories complete (02 working & 01 standby - Each of 50% cap)(b) 3No. - Suitable HP TEFC squirell cage induction motor with class F insulation 2900 rpm, operating on 415 volts, 3 phase, 50 Hz A.C. (02 working & 01 standby - Each of 50% cap).(c) Lot- Insulation of suitable thickness same as chilled water pipe line properly clamped to pump in two semi-circular sections as per specification. 113 (d)Lot- Mounting frame with Anti vibration pads.(e) Lot- RCC/PCC cement concrete foundation for the pump unit (2 working simultaneously & 1 standby-Each of 50% cap).Note:- The contractor shall provide the calculation for the discharge & head of pump along with design calculations after acceptance of tender. In case of deviation of head upto 40 Mtr no price adjustment shall be done. However beyond 40 Mtr of total head adjusted through a deviation order as applicable. 114 Centrifugal mono block type condenser water pump set of suitable capacity (as per design) capable of delivering min. 208 USGPM of water each comprising of the following and complete all as specified and as directed 115 (a) 3 Nos.- mono block type end suction pump with bronze impeller, SS Shaft.Cl body and mechanical seal with all accessories complete (02 working & 01 standby Each of 50% cap)(b) 3No. - Suitable HP TEFC squirell cage induction motor with class F insulation2900 rpm, operating on 415 volts, 3phase, 50 Hz A.C. supply (02 working & 01 standby - Each of 50% cap). (c) Lot- Mounting frame with Anti vibration pads.{d) Lot- RCC/PCC cement concrete foundation for the pump unit (2 working simultaneously & 1 standby- Each of 50% cap 116 Centrifugal mono block type hot water pump set for hotwater circulation (1 Working + 1 standby) of suitable capacity (as per design) for AC plant each comprising of the following and complete all as specified and as directed 117 (a) 2 Nos.- mono block type pump with bronze impeller, SS Shaft,CI body and mechanical seal with all accessories complete (1 working & 1 standby-Each of 50% cap). (b) 2 Nos. - Suitable HP TEFC squirell cage induction motor with class F insulation 2900 rpm , operating on 415 volts, 3 phase, 50 Hz A.C. supply (1 working & 1 standby-Each of 50% cap) (c) Lot- Mounting frame with Anti vibration pads.(d) Lot- RCC/PCC cement concrete foundation for the pump unit (1 working & 1 standby-Each of 50% cap). 118 AHUDoubleskinfloormounted typeairhandlingunitsofsuitablesize fabricated& assembledcomplete,madeof43mmthickpanelsconsistingofGI casingof thickness 0.8mm outside layer and 0.8mm inside layer, injected at factory by moulding machine with CFC free polyurethane foam (PUF) insulation of minimum density 42Kg/ M3 factory injected between them by injection moulding machine, completewith direct driven: plugfan ofrequiredstaticpressure.completewith blower section and filter section with filter of 10 micron at 90% efficiency, 8 RWD chilled water coil constructed out of copper tubes not less than 0.5mm thickness andaluminum fins, Suitable capacity TEFC drive squirrel cage induction motor 415 volts, 50 Hz , 3 ph , AC centrifugal access door etc. complete as per std. specification of suitable capacity. 119 (a) Coil of copper tube and aluminium construction.(b) Pre filter(MERV 6) in supply air stream.(c) Squirrel cage induction motors suitable for 415 volts, 50 Hz, AC supply meeting criteria as per ASHRAE standard 90.1-2007 and high efficiency(d) Fan belt drive package.(e) Vibration isolators. 120 (f) SS 304 drain Pan.(g) Drain pipe of suitable size.(h) Flexible duct 20 G .j) Necessary control arrangement to switch off the fan in case of fire, indicating lamp & all safety precaution in a powder coated GI enclosure with necessary power and control cable as required.Note:(i) The floor slope of AHU room shall be such that all condensate is made to drain to outside AHU room.(ii) The AHU should have space for humidifire. 121 PAN type humidifier of suitable capacity made of stainless steel sheet duly insulated and of suitable capacity to maintain RH as per annexure A alongwith all necessary accessories such as steel water tank with float valve, water make up, overflow and drain connection, transducer shall be interlocked with the float switch supplied with humidifier and humidistat & controls etc. complete with necessary supports by MS structural steel as required, hangers, clamps supports from walls, floors and ceiling with painting with one coat of primer and two coats of paint to MS work.all as specified and directed 122 HOT WATER GENERATOR (HWG)Electrically operated Hot Water generator of suitable capacity (as per design) made of 8mm MS sheet and dish end made of 10mm MS having 16 gauge stainless steel linning with heaters arranged in banks and controller and thermostat so that required qty of hot water is generated at 50°C with nominal variation, including 100mm thick rasin bonded fiber glass insulation of 24 KG /M3 density finished with 1.25mm thick aluminium sheet cladding including necessary electrical panel with automatic controls including inlet and outlet connections for water complete with pressure release valve,low levelcut-out,Auto-ventsight-glassallasper specifications, complete as required and approved (Degree of protection IP-52 with IS 2147) 123 Design, Supply, Installation, testing and commissioning of induced draft counter flow, vertical discharge type FRP cooling tower of suitable heat rejection capacity as per design or as per OEM recommendation having Minimum Water flow/tower 520 USGPM with ultra- voilet treated durable & high efficient PVC filling with integral louvers and drift eleminators, open pan suitable for water distribution complete with hot FRP water basin. fitted with spray nozzles or having self rotating sprinklers, statically & dynamically balanced axial flow type fan direct driven or driven through reduction gear box with TEFC induction motor fan motor with blade 1 Nos suitable for 415 Volt & supporting structure , suction screen, make up quick filling arrangement, over flow and drain connections with necessary valves and suitable inspection ladder , access arrangement for cooling tower interior, installed on MS girders of suitable size fixed in masonry foundations with cement concrete footing, second class brick work and cement mortar 1:6 along with all necessary accessories, basin fittings, anti vibration mountings etc. includingg LT cable for power supply etc. Note:- Next higher capacity of cooling tower will be supplied by contractor with out any extra cost to Govt. in case non availability of.capacity as specified. 124 ELECTRAL WORKS(i) The outgoing feeders as indicated in Schedule of works shall have suitable range of followings (except capacitor feeders).(ii) All Digital electronic MFM cum KWH meter provided shall equipped with three phase indicating lamps.(iii) 415/110 V suitable rating control transformer shall be provided for aux.control supply.(iv) Wiring with space heater, thermostat and control MCBs shall be provided for all vertical sections of main LT panel.(v) All incoming as well as outgoing ,feeders shall have pad locking facility.(vi) Suitable danger board shall be provided.(vii) MCB/ MCCBs should have minimum breaking capacity as follows:-(a) Less than 63 Amp -10 KA(b) 63 Amp to 125 Amp -16 KA(c) above 125 Amp upto 250 Amp -25 KA(d) above 250Amp upto 400 Amp -35 KA(e) above 400 Amp -50KA(f) 630 Amps and above - ACB will be provided in lieu of MCCB/MCB.(vii) All MCCBs shall be provided with front rotary handle and operating mechanism for door interlock with Pad locking of MCCBs handles in OFF position. 125 (viii) All hinged door shall be earthed through 2.5 sqmm tinned braided copper wire (ix ) Panels shall be powder coated with gray paint shade no. RAL-7032 of IS-5. (x) Minimum Degree of protection for following type of distribution panel enclosure shall be as per IS:60439.(xi) All motor feeders MCCBs shall be of motor duty (xii) Supporting/Base rigid steel framework.(xiii) TPN MCCBs shall mean 3 pole MCCBs with adequate size of neutral link.(xiv) Final rating & various parameter, in addition to the specified below shall be selected on the bases of ambient conditions at site, client specific requirements, requirement for the NOC from various statutory authorities, as per detail designed stage calculations.(xv) Each Panel incomers/outgoings shall be provided with suitable contacts/terminals to receive the Al. Conductor cables given in the latter section. 126 (xvi) All Panel shall be minimum IP-54 for indoor environment except for outdoor conditions those are mentioned separateyly(xvii) All MCCB shall be with lcu =lcs.(xviii) All ACB shall be with lcu=lcs=lcw.(xix) All ammeter/ voltmeter shall be of minimum 0.5 Cl accuracy.(xx) All starter of more than 5 HP motor shall be star-delta and rest Shall be of DOL type. 127 Design, manufacture, Supply, fixing, testing and commissioning main LT panel 01 No.Cubicle type floor mounted front operated Main HVAC and AHU electrical / control panels as per IEC 61439 for 3 phase, 415 volt, 4 wire 50Hz AC supply system, fabricated in compartmentalized design with CRCAsheet steel 2 mm thick for frame work and covers 3mm thick for gland platesincludingcleaningand surface treatment with 9 tank process before powder coating in approved shade, having suitable Amps capacity extensible type TPN Aluminium Alloy Bus Bars with suitable rating neutral of high conductivity, DMC/SMC bus bar supports, with short circuit withstand capacity of 35KA for 1sec, bottom base channel of MS section not less than 100mmx75mmx5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 32mmx5mm at the rear with 02 Nos. earth stud, solid connections from main bus bar to switch gears with required size of with earth bus, AL bus bars, numbering & powder coated, CPRI approved panel including interconnection wiring, indicating lamps etc· and with the under mentioned incoming & out going components complete. The cubicle panel shall be free floor standing type, complete. The panel shall have 128 Incoming :- (a) 1 No 4 pole MCCB of suitable cpacity with rotary handle with microprocessor based O/C, S/C & E/F release, of suitable capacityasperdesign rating for AC plant.(b) UV protection, OV protection,Single phasing, Phase reverse protection shall be in main incomer.(c) 1 NO Multifunction meter 96x96 mm with selector switches and suitable CTs.(d) Phase indicating lamps for Ph RYBwith control fuses as required(e) Breaker On/Off trip indication(f) 1 Set of suitable capacity rectangular section TP & N Aluminum Bus Bars with color coded PVC heat shrinkable sleeves.(g) 1 Set digital type 3 phase static KWH meter 3 phase 415 volts,CTs operated complete with CTs of appropriate ratio and VA burden Outgoings:-(a) Suitable Nos. TPN MCCB/ MCB, of suitable capacity as per design rating with adjustable thermal and magnetic setting, electrically operated as outgoing feeders for 3 Nos. chilling unit. 129 (b) Suitable Nos. FP MCCB of suitable capacity as per design rating with DOL / star delta starter for motor, over load relay with built in single phasing protection and outgoing feeder to chilled water, condenser water & HWG . The compartment shall contain an indicating lamp with MCB for ON status of pump motor.(c) Suitable Nos. FP MCCBs of suitable capacity as per design rating operated as out going feeder for CT fan motor panel.(d) Suitable Nos. FP MCCBs of suitable capacity as per design ratingoperated as out going feeder for AHU PanelNote :-Any other control/circuit bracket required for operation of plant shall be provided within quoted rate. 130 Design, manufacture, Supply, fixing, testing and commissioning of cubicle type wall mounted panel, dead front, fabricated form 2 mm thick CRCA sheet powder coated sheet steel CPRI approved panel including anchoring into the wall ( AHU panel.), lncoming:-(a) 1 No 4 pole MCCB with rotary handle with microprocessor based O/C, SIC & E/F release, of suitable capacity as per design rating for AHU panel.(b) UV protection,OV protection, Single phasing,Phase reverse protectionshall be in main Incomer..(c) 1 NO Multifunction meter 96x96 mm with selector switches and suitable CTs.(d) Phase indicating lamps for 3 Ph RYB with control fuses as required(e) Main MCCB On/Off trip indication(f) 1 Set of suitable capacity rectangular section TP & N Aluminum Bus Bars with color coded PVC heat shrinkable sleeves. 131 Outgoings:-(a) Suitable ( Qty) No FP MCCB of suitable capacity as per design rating with DOL / star-delta starter for AHU motor, over load relay with built in single phasing protection. The compartment shall contain lamp with MCCB for ON status for AHU motor.(b) Suitable (Qty) No TPN MCCB of suitable capacity as per design rating with starter for Pre Heater. The compartmentshall contain an indicating lamp with MCB for ON status of Heaters.(c) Suitable (Qty) No MCB TP , 10 KA for 3 Way Valve & Control system with toggle switch(d) Over load relay with built in single phasing protection as per rating , suitable for motor duty and able to withstand fault level of 20 KA.Note: - Any other control/circuit bracket required for operation of plant shall be provided within bore all quoted. 132 Design, manufacture, Supply, fixing, testing and commissioning of cubicle type wall mounted panel, dead front, fabricated form 2 mm thick CRCA sheet powder coated sheet steel CPRI approved panel including anchoring into the wall (CT fan motor panel.)Incoming:-(a) 1 No 4 pole MCCB with rotary handle with microprocessor based O/C, SIC & E/F release, of suitable capacity as per design rating for CT panel.(b) UV protection,OV protection, Single phasing, Phase reverse protectionshall be in main incomer.·(c) 1 NO Multifunction meter 96x96 mm with selector switches and suitable CTs.(d) Phase indicating lamps for 3 Ph RYB with control fuses as required(e) Main MCCB On/Off trip indication(f) 1 Set of suitable capacity rectangular section TP & N Aluminum Bus Bars with color coded heat shrinkable sleeves. 133 Outgoings:-(a) Suitable ( Qty) No TP MCCB of suitable capacity as per design rating with DOL / star-delta starter for Fan motor, over load relay with built in single phasing protection. The compartment shall contain lamp with MCCB for ON status for Fan motor.Note: - Any other control/circuit bracket required for operation of plant shall be provided within bore all quoted. 134 Design supply layin and fixing along the poles or passing through pipes or laid under floor or through walls etc jointing and testing (XLPE insulated) galvanised steel strip / wire armoured electric cable 1100 Volts grade, heavy duty, ISI marked, with Al / Cu conductor and overall served with an outer sheathed of PVC, of suitable cross section area and No of Core of required length (from main LT Panel) complete all as specified and as directed for following :- 135 For Chiller / HWG / Pumps (Copper conductor cable) 136 For AHU sub panel / CT fan motor sub Panels (Aluminium conductor cable) 137 Supply layin and fixing along the poles or passing through pipes or laid under floor or through walls etc jointing and testing PVC insulated flexible electric cable 1100 Volts grade heavy duty ISI marked with Al / Cu conductor and overall served with an outer sheathed of PVC, of followingcross sectional areacomplete all as specified and as directed for following :- 138 For control 3c x 1.5 Sqmm (copper) Note:-Cable, Wire & End terminations :- Following are deemed to be incluted in item rate quoted(i) Cables be laid on cable tray / surface / in duct / trench, including clamps, ties, excavation work etc as required and specified. (ii) End termination with brass compression gland and aluminium lugs for various sizes of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required and specified. 139 (iii) Providing and fixing of control wiring/ power cabling with various sizes of copper conductor armoured cable making connection etc as required and specified.(iv) Providing and fixing 25x5mm size GI strip for earthing. (v) Fabricating and installing of desired sizes of hot dip galvanised ladder type cable trays including horizontal vertical bends, reducers tees,cross memebers and other acessories as required and duly installed from the ceiling/ side walls with suitable size of channels/ angles with anti corrosive painting, full threaded GI rods etc. complete as required & approved by Engr-in Charge.(vi) Any earth work and protection cover sand cushioning etc required to lay the cable in trenches are deemed to be included in the quoted rate. Earth work for cable be done as per specified standard manner. 140 Suitable quantity of Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground (Earth pit not less than 2.25 m deep below normal ground level) surrounded from all directions with charcoal dust, salt and edge of earth plate not less than 1.5 m below ground level connected to galvanized iron strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers made of glavanized iron and protected by galvanized iron pipe light grade 40 mm bore and watering pipe 20mm dia 141 medium grade with funnel and wire mesh as specified and connected all as shown in electrical plate No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B-1 in chamberand 80 mm thick precast RCC 1:2:4 type B-1 using XPM weighing not less than 4Kg/Sqm for cover slab/coping complete all as specified and as directed. 142 Note: (i) The unit rate quoted by tendrer is deemed to be include for necessary excavation, removal of surplus soil, PCC foundation, MS Iron Cover Etc.(ii) All panels ( Main and sub panels) be connected minimum with one pair (two nos) of separate earthing for each.(iii) All Chiller motors be connected minimum with one pair (two nos) of seperate earthing.(iv) All other electric motors/ euipments be connected with loop earthing from connected panel with suitable earth conductor of minimum size GI strip 25x3mm .(v) All terminations shall be made with proper lugs in the approved manner. 143 Suitable nominal sizes as per design / OEM recommendation of chilled plumbing pipes MS C CLASS as per IS: 1239, inside/outside the building (with necessary clamps, vibration isolators and fitting like elbow,flanges, union etc. but excluding valves, strainers, gauges etc.) cut to required lengths and welded at joints .Chilled water pipe shall be insulated with closed cell Nitrile Rubber insulation of density 40-42 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C. Nitrile insulation shall be apllied after pressure testing of pipe line and shall be fixed with OEM recomended Rubber based adhesive. The chilled water pipe line shall be finally wrapped with 7 milli fiber glass cloth and finally apply two coat of UV paint.matching with building colour or as per Engr-in-charge decision.Note : (i) The pipes of sizes 150mm & below shall be MS C class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS:3589 from minimum 6.35mm thick MS sheet for pipes upto 350mm dia and from minimum 7mm thick MS Sheet for pipes of 400mm dia and above. Minimum thickness of insulation for pipes should not be less than given below :-. 144 125 mm dia Pipe (25 mm thick Insulation) 145 100 mm dia Pipe (25 mm thick Insulation) 146 80 mm dia Pipe (19 mm thick Insulation) 147 65 mm dia Pipe (19 mm thick Insulation) 148 50 mm dia Pipe (19 mm thick Insulation) 149 40 mm dia Pipe (19 mm thick Insulation) 150 32 mm dia Pipe (13 mm thick Insulation) 151 20 mm dia Pipe (13 mm thick Insulation) 152 Valves strainers, Gauges etc(Qty and size as per design requirement) in chilled/hot water plumbing duly insultaed to the same specification as the connected piping and adequately supported as required. 153 Butter Fly Valves (Manual) (Qty and size as per design requirement) with CI body Stainless steel disc, nitrile rubber seal & O ring, minimum PN 10 Pressure rating for chilled water circulation of suitable size. Valves shall be insulation with the same as per pipe line insulation material 154 Balancing valve, globe type, (Qty and size as per design requirement) Minimum PN 16 rated, balanced/high rangeability control valve duly insulated to the same specifications as the connected piping as per following specificationNominal Pressure PN16Medium Temperature: AS per design condition.Body Mateial: IS:210, FG 220 CIStem Material: ASTM A276,Disc Material: Stainless steel discHand Wheel:Cast IronLeakage Rate: No visible leakageMedium Type: Water 155 Y-type strainer,(Qty and size as per design requirement) with Cl/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with accessories etc, as required all as specified. 156 Non return valve of suitable size, qty and placed at location as per design, with dual plate of CI body , stainless steel plates, vulcanised NBR seal flanged ends and minimum PN 10 Pressure rating, all as specified. 157 Gun metal Ball Valve set,of stuiable size, qty and placed at locaiton as per design with and without Y strainer with bronze body, flanged end type for chilled/hot water circulation all as specified. 158 Three Way modulation valve ( Qty and size as per design requirement) with spring return function & fitting with modulating actuators controlled by electronic controller in chilled water lines at each air handling unit. The actuator shall have required shut off capability of minimum 4 bar rating. The valve shall be suitable size as per design size and duly insulated to the same specification as the connected pipe all as specified and as directed. 159 Automatic air-vent ( Qty and size as per design requirement) with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide capm etc. suitable for minimum operating pressure of 10 bar and minimum operating temperature 115° C respectively, installed on all high points in the water piping system and as per design requirement to automatically remove the trapped air, installed on all high points in the water piping system to automatically remove the trapped air etc. as required all as specified and as directed. 160 Industrial type pressure gauge 100mm size ( Qty and size as per design requirement) with gun metal / brass construction isolating valve complete with all accessories as required. 161 Mercury-in-glass industrial type thermometers, qty and size as per design requirement, with gun metal / brass construction isolating valve complete with all accessories as required. 162 Water flow switches brass / polymer construction, qty and size as per design requirement for water circuit complete with fittings, all as specified and directed 163 Proportional cooling only thermostats, qty and size as per design requirement, for the Air Handling Units complete with required controls wiring/installation kit etc.as per design and as specified. 164 Proportional Heating only thermostats, qty and size as per design requirement, for the Air Handling/FCU Units complete with required controls wiring/installation kit etc. as per design and as specified. 165 Proportional humidistate for the Air Handling Units, qty and size as per design requirement, complete with required controls wiring/installation kit etc. as per designed drawings and as specified. 166 Suitable Nominal sizes, qty and size as per design / OEM recommendation of condenser water pipes MS C CLASS as per IS: 1239, along with necessary clamps, vibration isolators and fittings such as bends, tees etc but excluding strainer and gauges etc adequately supported on rigid supports/buried in ground including excavation & returning and filling etc complete all as specified and directed. 167 Butter Fly Valves (Manual) with Cl body, qty and size as per design, Stainless steel disc, nitrile rubber seal & O ring, minimum PN 10 Pressure rating for chilled water circulation . Valves shall be insulation with the same as per pipe line insulation material 168 Y-type strainer, qty and size as per design with Cl/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection with accessories etc, as required all as specified and directed 169 MS/Cl POT strainers, qty and size as per design and as per drawing, including packing material, fixing bolts etc and any alterations required for proper fixing all as specified and directed. 170 Gun metal Ball Valve set, qty and size as per design all as specified. 171 GI class B pipe of suitable size as per design and drawing for cable protection & water supply connection of cooling tower, tank etc 172 GI pipes for Drain pipes, laid qty as per design and approved drawing medieum class as per IS: 1239, inside/outside the building (with necessary clamps, vibration isolators and fitting like elbow,flanges, union etc. but excluding valves, strainers, gauges etc.) cut to required lengths adequtely supported and duly insulated with 13mm thick closed cell elastomeric nitrile rubber of classO insulation applied by adhesive confirming to standard specifications complete with type 3, grade 1 roofing felt strip (as per IS;1322 as ammended upto date) at joints. 173 Auto Air purge valve of brass construction of qty and size as per design and approved drawing. ( Air vent will be fitted with an isolating ball valve- gun metal/ brass construction. 174 Flexible connections Flexible connector for pipe of required size and qty as per design and approved drawing having min 16 PN working pressure with anti vaccum rings complete with flanges, nuts, bolts, seal etc to be installes at chiller section anddischarge. 175 Motorised combined fire damper of desiged size complete with control panel, inter connecting wiring at location shown in approved drawing all as specified and directed. 176 Duct insulation in AC/Attic space outside building with aluminium foil backed minimum 25mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of minimum density 32 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an average temp of 40 deg C, complete with application with rubber based adhesive as per OEM recomandation including making good the damages to match with the existing specification of the building, complete all as specified and direcetd. 177 Acoustic insulation of duct as shown on approved designed drawing with minimum 25 mm resin bonded fibre glass, of min 48 kg/cum density, covered with and 28 Gauge Aluminium perforated sheet all as specified and directed. 178 Under deck insulation of the exposed portion of the roof/wall of AHU Rooms to be air conditioned with min 13 mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of min density 30 Kg/cum and covered with aluminium foil complete with application with rubber based adhesive as per OEM recomandations all as specified. The thermal conductivity of the material should not exceed 0.035 W/MK at an average temp of 40 deg C, complete · all as specified including making good the damages to match with the exisiting specification of the building 179 Design, supplying, installing, balancing, testing and commissioning of factory/ Site fabricated Galvanized steel sheet, rectangular ducting, qty and specifications as per design and approved drawing, complete with neoprene rubber gaskets, elbows, splitter damper vanes, hangars, supports as per SMACNA in accordance with design and approved shop drawings and as per desined specifications Note for Duct(i) The contarctor shall submit the shop drawings of ducting layout for the approval of GE before execution of work.(ii) The duct work shall be as per IS-655(iii). The Galvanized steel sheet for duct work shall conform to class viii with zinc coating of 120 gm/sq mtr as per IS-277(2003). 180 Flexible connection constructed of fire resistant double resin sleeve as per approved shop drawings and specifications, complete all as specified and directed. 181 Powder coated aluminium grill/Diffuser with volume control dampers, qty and specifications as per design and approved drawing, complete all as specified and directed. 182 Jet diffuser with volume control dampers for supply air , qty and specifications as per design and approved drawing, complete all as specified and directed. 183 GI volume control dampers, qty and specifications as per design and approved drawing, complete all as specified and directed. 184 Powder coated extruded aluminium section fresh air grill, qty, size and specifications as per design and approved drawing, in weather maker room with volume control dampers, bird screen etc all as specified and directed 185 HOPE make up tank qty and size as per design and approved drawing of minimum size 500 Ltr. on the roof of plant room with air vent and drain connection & overflow, mak up, qqnnection with float valve etc as required all as specified and directed 186 HOPE expansion tank as per design requirement of minimum size 1000 Ltrs complete with suitable FR-XLPE/XPE min 13 mm thick, of minimum bulk density 28 + 4Kg/cum covered with vapour barrier and finished with min 0.5mm thick aluminium cladding applied with rubber based adhesive recomanded by OEM complete with air vent and drain connection float valve, quick fill and control valves etc as required all as specified and directed. 187 SITC of MS Powder coated perforated cable tray on wall , roof etcshall be of minimum 1.6 mm thickness,qty and size as per design and approved drawings 188 Design , manufacture, supply, fixing, testing and commissioning of cubicle type wall mountd panel, dead front, fabircated from 2mm thick CRCA sheet powder coated sheet CPRI approved panel including anchoring into the wall (AHU Panel) Incoming: (a) 1 No 4 Pole MCCB with rotary handle wiht microprocessor based O/C, S/C & E/F release, of suiatable capacity as per design rating for AHU panel. (b) UV protection, OV protection, single phasing, phase reverse protection shall be in main incomer. (c) 1 No multifunction meter 96x96 mm with slector switches and suitable CTs (d) Phase indicating lamps for 3 ph RYB with control fuses as required (e) Main MCCB on/off trip indiction (f) 1 set of suitable capacity rectangular section TP & N aluminium bus bars with color coded PVC heat shrinkable sleeves.Outgoings:-(a) Suitable (Qty ) No FP MCCB of suitable cpacity as per design rating with DOL/Star-delta starter for AHU motor, over load relay with built in single phasing protection.The compartment shall contain lamp with MCCB for ON status for AHU motor. (b) Suitable (Qty) No TPN MCCB of suitable capacity as per design rating with starter for Pre Heater.The compartment shall contain in indicating lamp with MCB for ON status of heaters (c) Suitable (Qty No MCCB TP, 10 KA for 3 way valve & control system with toggle switch (d) Over load relay with built in single phasing protection as per rating, suitable for motor duty and able to withstand fault level of 20 KA. Note: Any other control/circuit bracket required for operation for plant shall be provided within bore all quoted. 189 GI pipes for Drain pipes, laid qty as per design and approved drawing medieum class as per IS: 1239, inside/outside the building (with necessary clamps, vibration isolators and fitting like elbow,flanges, union etc. but excluding valves, strainers, gauges etc) cut to required lengths adequtely supported and duly insulated with 13mm thick closed cell elastomeric nitrile rubber of class O insulation aplied by adhesive confirming to standard specifications complete with type 3, grade 1 roofing felt strip (as pe IS : 1322 as ammended upto date) at joints. 190 Auto Air purge valve of brass construction of qty and size as per design and approved drawing. ( Air vent will be fitted with an isolating ball valve- gun metal/ brass construction. 191 Flexible connection: Flexible connector for pipe of required size and qty as per design and approved drawing having min 16 PN working pressure with anti vaccum rings complete with flanges, nuts bolts, seal etc to be installes at chiller section and discharge. 192 Motorised combined fire damper of desiged size complete with control panel, inter connecting wiring at location shown in approved drawing all as specified and directed. 193 Duct insulation in AC/Attic space outside building with aluminium foil backed minimum 25mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of minimum density 32 Kg/cum. The thermal conductivity of the material should not exceed 0.035 W/Mk at an avererage temp of 40 deg C, complete with application with rubber based adhesive as per OEM recommendation including making good the damages to match with existing specification of the building, complete all as specified and directed. 194 Acoustic insulation of duct as shown on approved designed drawing with minimum 25 mm resin bonded fibre glass, of min 48 kg/cum density, covered with and 28 Gauge Aluminium perforated sheet all as specified and directed. 195 Under deck insulation of the exposed portion of the roof/wall of AHU Rooms to be air conditioned with min 13 mm thick closed cell chemically cross linked fire retardant polyethylene foam insulation of min density 30 Kg/cum and covered with aluminium foil complete with application with rubber based adhesive as pr OEM recommendations all as specified. The thermal conductivity of the material should not exceed 0.035 W/MK at an average temp of 40 deg C, complte all as specified including making good the damages to match win the existing specification of the building. 196 Suitable nominal size as per Design/OEM recommendation of Hot water plumbing pipes MS C class inside/outside the building as per item No. 7.40 to 7.48 here-in-above with necessary clamps etc including different type valves, strainers etc complete in all respect. 197 The contractor will operate the plant for 24 hours in three shifts, each shift of 8 hours after successful completion of Phase - I test until successful completion of first phase-II test. Rates quoted by the tenderer will be deemed to be included for this provision and no extra payment shall be admissible on this account 198 EOT CRANE 199 Design, Supply, installation in position, testing and commissioningof flame proof EOT crane double girder box type class II, indoor type for hazardous area Zone - 2 gas group IIA & IIB as per IS 2148 (latest edition) including other relevant applicable IS of 2 ton capacity with all motion ie. long travel cross travel and hoisting having hook height 4M electrically operated through pendant push button station floor operated type complete with and including main frame, bridge girders/ box girders ISMB / Beam, end carriage, trolly with frame, crab, buffers, gears with gears boxes, shafts, rope drum, rope shleeves, wire rope, wheel, lifting hook, brakes, motors, limit sweetches, control panel, pendant push botton station, wiring cables etc as per IS 3177, 807 & 2148 with following technical specification :- 200 (a) Capacity: 2 Ton (2000 Kg)(b) Overload capacity: 25%(c) Class duty : II Indoor type (d) Hook height: 4 M (e) Hoisting speed drive : 3M/Minut with VVVF drive (f) CT Speed10 M/Minut with VVVF drive (g) LT speed: 10M/Minut with VVVf drive (h) Operation from floor: Pendant push button (j) Hoisting motor: Qty & capacity as per CT motor & LT motor manufacturer design(k) Wire rope : Suitable dia as per manufacturer design with minimum 4 falls, tensile strength 180kg/Sqmm.(l) Main girder: Box type(m) Long travel span: 25M (n) Cross travel span: 14M(o) Brakes: Hoisting cross and long travel motions shall be provided with fall safe electro Hydraulics thrust or operated brakes.(p) Any unforeseen item required for complete operation of flame proof crane as specified by OEM. 201 All as per ser No 8.01 and 8.02 complete here in before but long travel span and cross travel span shall be as under :-Long travel span: 29MCross travel span: 14M 202 All as per ser No 8.01 and 8.02 complete here in before but long travel span and cross travel span shall be as under :-Long travel span: 25MCross travel span: 13M 203 Gantry Guirders made out of ISMB/ISMC for EOT crane as per OEM . Note for Ser item No 8.01, 8.03, & 8.04:- (i) Design & drawings of EOT crane shall be submitted to Accepting Officer for approval alonwith all type test report of flame proof EOT & their components / items of crane from Govt approved Lab before placement order by the contractor. (ii) Pre-dispatch factory inspection of flameproof EOT cranes shall be carried out by rep of Accepting Officer at manufacturers (OEM) premises within overall cost quoted by the contractor.(iii) For proper functioning of cranes, any unforseen items or any minor modifications requied to be carried out, shall be deemed to be included in quoted rate.(iv) Pre-commissioning test of cranes shall be carried out by rep of Accepting Officer. 204 DEMOLITION WORKS 205 Taking out of old unserviceable sluice valve / NRV with complete accessories from existing pipe line of size 80/100 mm boreincluding excavation work if any, complete all as specified and as directed. 206 Demolition of oldvalve pit any type any size complete and taken out of old broken unserviceable accessories from valve pit and its connection and fixing accessories including exavation work,complete all as specified and as directed.
Contract Date: Oct 15, 2025 Contract Value : 19.48 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
47.
Defence #8036829 AOC
REPAIR /MAINT/SERVICING OF POWER SUPPLY/DISTRIBUTION SYSTEM CENTRAL S/S, C S/S, B S/S , E S/S SRE & BCR ADJOING LOCATIONS AND CONNECTED ITEMS IN DOMASTIC AREA AT AF STN, SULUR; SCHEDULE A BOQ 2 Supply andfix in repairHT, 11 KV grade, barrel fuse of capacity upto 40 Amps suitable for HT Switch fuse unit of Make ABB including taking down existing one complete all as spceified and directed. 3 Supply andfix in repair HT, 11 KV grade, barrel fuse of capacity upto 50 Amps suitable for HT LBSincluding taking down existing onecomplete all as spceified and directed. 4 Supply only Electrical Rubber hand gloves as perISI specification for operating voltage 11KV complete all as specified and as directed. 5 Supply and lay graded stone aggregate of 40mm size, spread and leveled around 4 pole/ 2 pole structure, transformer, sub stn, panel board yard including removal of existing complete all as specified and as directed. 6 Taking out existing old unservicable/burnt gang operated switches or DO fuse assys complete all as directed by the Engr-in-Charge. 7 S & Fswitch air break, gang operated, out door type, triple pole, HT 11000 volts, up to 400 Amps, vertical type with 3 insulators mounted with fixed contacts of phospor bronze and moving contacts of copper, manually operated from ground level with operating mechanism including mild steel galvanised light grade 25mm bore operating rod, pad locking arrangement,complete all as specified and directed by the Engr-in-Charge. 8 S & F in repairs drop out expulsion fuse assembly with fuse carrier, triple pole HT 11000 Volts, 200 Amps, out door type(having two Nos post insulators mounted on MS Channel for each pole ) complete all as specified and directed by the Engr-in-Charge. Make : PACTIL/JAIPURIA 9 S & F lightening arrestors Expulsion type complete with all fitting, transmission class, discharge capacity 10 kilo to 30 kilo Amps suitable for 11000 Volts and connecting to earth wire complete all as directedincluding taking down old u/s bursted lightning arrestors from Load break switch complete all as specified and directed. 10 S & F in repairs cable jointing kit for 1.1 KV grade cable for stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed. Make : Reychems, Densons, M-Seal 11 S & F in repair out door cable end jointing kit, inddor termination (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (earthed) grade, of cross sectional area185 Sqmm 3 corecomplete all as specified and directed Make : Reychems, Densons, M-Seal 12 Servicing the existing Drop out fuse assembly, of capacity 200 Amps, 11 KV, 3 Pole, including replacing worn out/ rusted nuts, bolts, clamps, washers, etc. and providing coloured sleaves for jumper connections complete. 13 Taking out and repairing / overhauling of air break gang operated switch 200 Amp, 11 KV capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically / horizontally, replacement of broken/ worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly on contacts re-fixed the same after repair complete including new nut bolts and washer etc all as specified and directed.Note : The quoted rate by contractor shall include the serviceable parts in positionand replacement of U/S parts with new one. 14 Repairing, overhauling, Servicing & testing of RMUs, 11 KV, 20 KA, 3 Phase, 50 Hz, AC Supply system, outdoor type for trouble free operation, consisting of one/two incomming and one/two outgoingwith SF6 gas filled VCB/ LBS/Fuse units, metal clad totally enclosed free standing floor mounted, non draw out type includingthe following works complete all as specified and directed. Make of RMU : ABB 15 Note for Item No 14:- The Work shall be carried out through the authorised service engineers of the OEM only 16 (b)Servicing of Manual operated, 11kV, three position load break switch with snap-action knife blade mechanism along with associated earthing switch. 17 (c)Servicing of true position mechanical indication of switch position ON, OFF and EARTH on the front facia of the panel for proper indication. 18 (d)Checking and tightening control wiring and rectifying the defects if any. 19 Repairing, overhauling, Servicing & testingof Vaccum circuit breaker11 KV, 630A to 800 Amps, 350/250 MVA, 66 KA Peak, 3 Phase, 50 Hz, AC Supply system, indoor type for trouble free operation, and VCBs are for incoming , Bus coupler & Bus riser and Outgoings ,metal clad totally enclosed free standing floor mounted type,and vaccum circuit breakers, draw out type HT VCBs includingthe following works complete all as specified and directed:- MRS (ABB/Siemens/CG/magawin) 20 Note for item No 15 :-(a) The rate for following shall be deemed to be included in quoted rate. 21 (b) The entire job shall be carried out through the authorised service engineers of the OEM only in the presence of Engineer-in-Charge/JE E/M. 22 (c) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations. 23 (d) Servicing of 3 Phase epoxy base isolating spout assemblies complete with isolating contacts and a pair of automatic safety shutter individually locking system. 24 (e) Servicing of Breaker with motor charging asembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the VCB trolly from the panels. 25 (f) Servicing of Mech (caster lock) and elect inter locking system. 26 (g) Checking and tightening control wiring and rectifying the defects if any. 27 (h)Replacement of PTFuse 28 (j)Replacement of unserviceable spare parts will be measured and paid for separately. 29 (k)Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate. 30 (l)Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately. 31 Supply onlyagainst Item No. 14 above, Digital Microprocessor based Feeder protection Relay Model REF 615 for Over current and Earth fault including necessary necessary control wiring all as directed. 32 Supply only against Item No. 14 above, Electrical closing coil 110 volt DC operated all as directed. 33 Supply onlyagainst Item No.14 above, Electrical shunt trip coil 110 volt DC operated all as directed. 34 Supply only against Item No.14above,11 KV single phase in door resin cast CT of ratio 150/100/5A class 1.0/ 5P10,burden 15VA – 15 VA all as directed. 35 Supply onlyagainst Item No. 14above, Vaccum Interrupter (Vacum Bottle ) suitable for VCB all as directed. 36 Repair to transformer after disconnecting in coming HT connection and out going LT cable connection, draining out the transformer oil and keep in safe custody for reuse, disconnecting the breather assembly, temperature gauge, taking out the top cover of transformer 500 KVA, outdoor type, 11KV/433 Volt, step down, disconnecting LT/HT winding connections from LT/HT Bushing and carefully taking out LT/HT Bushing insulator and HT/LT Brass spindle, taking out gaskets of LT/HT Bushings and transformer top cover. Refixing exisiting LT/HT Brass spindle with Bushing insulators after replacing Gaskets, View glass of conservator tank, refixingall cable connections, top cover with new gasket, breather/temp gauge, refilling transformer oil, complete all as directed. 37 Note for item No 21 : (i) Transformer oil for topup, dehydration/filtration etc work will be measured and paid separately. 38 (ii) Complaints regarding Transformerwill be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x 7 days). 39 (iii) The contractor shall attend the complaint immediately. and shall report the Engr-in-Charge/JE( E/M) after completion. 40 (iv) Penalty of Rs 5000.00 per Job shall be applicable to the contractor if the complaint is not attended immediately. Note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. 41 (v)The decision of the Accepting Officer in this regards shall be final and binding. 42 (vi) In case the nature of job is such that the work cannot be completed within a period of 6 hrs then the same shall be brought to the notice of the GE/Engr-in-Charge and the period for the completion of the complaint shall be decided by the GE/EIC and thesame complaintshall be completed with in the period decided by the GE/EIC.The penalty of Rs 5000/ per Jobshall also be applicable to the contractorfor non-completion of complaint with in the time decided by the GE/EIC. 43 (vii) Transportation charges for transportation of transformer from site to workshop and after repair, workshop to site shall be borne by the contractor and cost thereof including tools and plants shall be deemed to be included in the unit rate quoted for this item. 44 (viii) Transformer oil shall be drained out by the contractor in suitable capacity mild steel drums to be arranged by the contractor. The said drained out transformer oil shall be refilled in the transformer duly dehydrated after repair and the cost thereof shall be included in unit rate quoted against the respective item of this schedule. 45 (ix) Testing of transformer after repair shall be carried out as per IS 2026 (Part 1): 2011at site in the presence of E-in- Charge/ JE and the cost of testing shall be deemed to be included in unit rate quoted against this item. 46 (x) The IR value of the dried winding before inserting the core in the shell shall be measured and recorded. 47 All as per itemNo. 21 above but of capacity of transformer 160 KVA to 200 KVA. 48 All as per itemNo.21above but of capacity of transformer upto 100 KVA. 49 M & L removing HT cable, 11 KV, XLPE 185 Sqmm 3 core with aluminium conductor, shifting to other location (not exc 2 KM distance) and relaying same cable in trenches/through pipes or bare in road crossings/ paths/drains/ducts/ floors /along poles/walls/ ceilings/ equipments etc. all as directed. Note No 1 : The unit rate is deemed to be included for :-(a)Excavation for taking down existing cable, shifting of cable as directed by the Engineer-in-Charge and relaying cable including required excavation as specified in SSR Part-I.(b)Disposal and return filling.Note No 2 : Sand cushioning and PCC cover shall be measured and paid separatley under relevant item. 50 Supply and laying in trenches/through pipes or bare in road crossings/paths/ drains/ ducts/ floors/along poles/equipments etc. Cable Under ground, cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables with aluminium conductor, earthed,11 KV grade,of cross sectional area 185 Sqmm x 3 core laid including taking down existing cable from trenches/ duct or any position all as specified and directed. 51 S & F Un-reinforced precast concrete cable cover class HV Type 1, flat size 300mm x 180 mm x 40 mm thick including taking down existing one of any size complete all as per specified and as directed. 52 S & Fin repairs Cable route indicators for HT cable with CI plate and angle iron 25x25x6mm showing MES,HT/LT cable,and voltage including excavation earth work and PCC complete all as per specified and as directed. . 53 S & F in repair Out door cable straight through jointing kit (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (Earthed) grade, of cross sectional area 185 Sqmm 3 core complete all as per specified and as directed. 54 M&L for insulation resistance testing of LT UG cable, XLPE insulated, armoured electric power cable with aluminium conductor 1100V grade of size from 300 sqm to 400 sqm 3.5 core after disconnecting the both end of the cable from transformer/ LT panel/ DBs and reconnecting the same after carryout the test all as specified here under and as directed by the engineer-in-charge . 55 M&L for insulation resistance testing of LT UG cable, XLPE insulated, armoured electric power cable with aluminium conductor 1100V grade of size from 70 sqm to 95 sqm 3.5 core after disconnecting the both end of the cable from transformer/ LT panel/ DBs and reconnecting the same after carryout the test all as specified here under and as directed by the engineer-in-charge . 56 Note for Item No. 29 & 30 :- (i) The quoted unit rate deemed to be included for disconnecting the cable from the transformer/ LT panel/DBs and reconnecting the same after the insulation resistance test. 57 (ii) The insulation resistance shall be tested between the conductors. 58 (iii) The insulation resistance shall be tested between the conductor and armoured/ earth. 59 (iv) The contractor shall arrange necessary testing instruments of suitable range and cost for the same shall deem to be included in the quoted unit rate. 60 (v) Test to be conducted in the presence of MES rep and concerned user and will record it in prescribed format. Test records duly signed by all to be submitted by the contrator to the Engineer-in-charge. 61 (vi) If any damages found at end termination of the cable, same shall be rectified by using suitable size of lugs / nuts & bolts for the reconnection of cable in transformer/ LT Panel/ DBs. cost for the same shall deem to be included in the quoted unit rate. 62 (vii) Cost of earth work required for disconnecting and reconnecting the cable shall deem to be included in the quoted rate. 63 (viii) Any major item required to rectify the defect shall be measured and paid seperately. 64 (ix)Checking of earth resistance of chemical/conventional earthing, identifying the earth and recording of test results in a prescribed format all as directedby Engr-in-Charge. 65 M & L removing of acumulated earth of any width and depth up to 30 cm. cleaning/cutting the grass around two/ four pole structure, transformer yard,sub stn,generator rooms etc and removing the grass waste to outside MD land completed all as specified and as directed.Note :- The unit rate is deemed to be included :-(a)Cuttingand filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked.(b)Cutting the grass/feilling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shalll be carefully filled up with moorum/red bajri well rammed and levelled. 66 Supply and fixing HT tape roll 35mm width Appx 5 mtr length completed all as specified and as directed. 67 M & L for disconnecting in coming HT and out going LT cable connections and taking down Transformer of any type/size/make/capacity from 2/4 Pole structure or from floor/pedestal and shifting to new location with in 3 KM and install where directed, refixingHT/LT cable connections complete all as specified and directed. Note:-Any damages happened in transformer during lifting/ shifting/ installation work, the same will be rectified by the contractor without any extra cost to the Govt 68 Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in hard/ dense soil complete all as specified and directed. 69 Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and directed.. 70 Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and directed.. 71 M & L riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge. The rate is deemed to be included. 72 S & F XLPEinsulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 240 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note :- Necessary excavation and earth work, sand cushioning & bricks for protection shall be measured and paid separately. 73 M & L boring of hole under road/ hard standing by trenchless technology including S&F HDPE pipe heavy duty of size 100mm bore fixed in repairs complete all as specified and directed 74 M & L cutting existing road/PCC/Drain for laying of DI/GI or any typeof pipe including necessary earthwork, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mmcomplete all as specified and directed. 75 Note for item No 40 :-The tenderer shall take into consideration for following points while quoting his rate for this item andthe unite rate is deemed be included for :- 76 (i) Earth work excavation in any type of soil 77 (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. 78 (iii) Removing excavated material to out side MD land 79 (iv)Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately 80 (v)150 mm thickPCC 1:2:4 type B1 as in any type of road 81 Supply only GI pipe 100 mm bore medium grade for cable protection completeall as specified and as diercted by Engr-in-Charge.Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thickPCC 1:2:4 typeB1 as in any type of roadroadwill be measured and paid separately. 82 Supply andreplacement or topping up of transformer Oil HV as per IS 335 of 1983 Part II after dehydration & testinganddielectric strength not less than 40 KV complete all as spceified and directed.Note :- The transformer oil shall be supplied in sealed barrel and shall confirm to IS -335 (including all amendments upto date) 83 Supply only cottan / Baniyan waste 84 M & L Out door cable end jointing kit (Heat shrinkable) suitable for XLPE under ground aluminium conductor cable, 11 KV (earthed) grade, of cross sectional area185 Sqmm 3 core complete all as specified and directed.Note:-(i)Taking out of existing cable, from VCBs, RMUs or Two Pole structuresand cutting faulty ends if required and re- fixing the same with out any damage of switch Gearsare deemed to be included in the item rate quoted)(ii) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x 7 days ). (iii) The contractor shall attend the complaint immediately and shall report the Engr-in-Charge/JE E/M after completion with in 6 hrs (iv) Penalty of Rs 2000.00 per Job shall be applicable to the contractor if the complaint is not attended with in half anhrs. Note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. (v)The decision of the Accepting Officer in this regards shall be final and binding. (vi) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same. 85 Supply, installation, testing & commissioning of maintenance free chemicalearthing system comprising 17mm dia copper bondedrod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducingliquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing oneall as directed. 86 The quoted rate shall also deemed to be included the following :- (i)Prior toinstallation of maintenance free chemicalearthing, soil resistivity test to be carried out at the location where earthingwork to be donein presence of Engr-in- Charge/JE (E/M),user and the report has tosubmitto Garrison Engineer with recommendation of manufacturer, if required additional interconnection ofearthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testingandsubmission of report with recommendationdeemed to be included in the quoted rate. 87 (ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors. 88 (iii) Rateofearth energizer compound of 25 Kg of 02 bags and earthresistance reducingliquid 10 litre per cane for each pit deemed to be included in the quoted rate. 89 (iv)Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work. 90 (v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete. 91 (vi) Copper strip of size 20 x 3 mm shouldbe fixed on proper post insulator at the instrument end ( The rate of earthing strip up to7.5 Mtrs is included in the quoted rate). 92 (vii)Testing of earth shall be carriedout in presence ofdepartmental and user representativeand report shall be submitted to Garrison Engineer duly signed by all concern. 93 (viii)Earth resistance tester will be provided by the contractor.Tester should be calibrated from authorised company/ lab. 94 (ix)Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned.After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained. 95 (x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion. 96 (xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including dry or rocky soil. 97 (xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained. 98 (xiv) The electrode shallcarry manufacturers name . 99 (xv) The connection clamp shall be permanentlly welded to the copper boundedrodto avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination. 100 (xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm. 101 (xvii)The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material. 102 (xviii) Sign boardof mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxideZinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge. 103 (xix)Earth work such as auguring andmaking good the surrounding area shall carried out in any type of soil. 104 S & F Earth pit cover madeof heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete including taking down existing one all as specified and directed.Note :- The contractor shall submit load bearing capacity certificate from the manufacturer. 105 S & F Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing. 106 Supply only against 14 of above Digital Microprocessor based Feeder protection Relayfor Over current and Earth fault including necessary control wiring all as directed. 107 M & L painting using heat resisting paint in two coats (one as finishing) over one coat of red oxide zinc chrome primer on external surface of transformer of rating upto 400 KVA using Ist quality paint and applying through spray gun machine on specified working pressure incl writing of MES/SM Nousing different colour including writing letter in given size etc after removing/scrapping/rubbing to old fedded paint and filler filling etc complete all as specified and directed.(Note- Quoted unit rate shall be deemed included cost of writing letters & filling depresion by using putty, complete Colour & shade shall be approved by Engr-in-charge)(Make- Asian/Berger/Dulex) 108 Dismantling/taking down of insulators of any type/size from HT/LT poles/DOs/GODs complete all as directed by Engr-in-Charge. 109 S & F post type, HT 11 KV insulators suitable for GO/DO switch, duly tested and including making connections with proper size of thimbles complete all as specified and directed. 110 S & F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia. for 11000 volts grade complete all as specified. 111 S & F disc type insulator, porcelain, vitreous, 145 mm high and 255mm dia, ball & socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified. 112 M & L Painting using heat resisting paint in two coats (one as finishing) over one coat of red oxide zinc chrome primer on external surface of transformer of rating above 500 KVA using Ist quality paint and applying through spray gun machine on specified working pressure incl writing of MES/SM Nousing different colour including writing letter in given size etc after removing/scrapping/rubbing to old fedded paint and filler filling etc complete all as specified and directed.(Note- Quoted unit rate shall be deemed included cost of writing letters & filling depresion by using putty, complete Colour & shade shall be approved by Engr-in-charge)(Make- Asian/Berger/Dulex) 113 Attending, Repairing/restoring of electric power supply in the AF stn Sulur area, after identifying fault in HT 11 KVor LT415 volt system, RMU,VCB,LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size. 114 Note for item No 55:(i) The abovework also include checking, detectionand rectifcation of LT/HT UG Cable faults at AF Area as and when directed by Engineer-in-Charge/ JE (E/M). 115 (ii) Hiring of cable fault detector to detect exact location of LT/HT UG cable fault deemed to be inclusive of quoted rate. 116 (iii) Major items required to be replaced/repaired will be measured under relevant items of schedule. 117 (iv) Excavation and earth work if required will be measured separately. 118 (v) Complaints will be given in person or through telephone by AGE/JE E/M round the clock (ie 24 Hrs x7 Days). 119 (vi) In case of minor defect, entire job shall be completed within 06 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 300/- per hours shall be recovered. 120 (vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same. 121 (viii) In case of major defect, the period for attending of complaint shall be decided by the GE/EIC by accessing extent of repair required through joint inspection by Engineer-in-Charge and authorised service agent of the equipment at the site. If complaint is not rectified within the stipulated period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs. 500/- per hours shall be deducted from the dues of the contractor. 122 (ix)Note that penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regard shall be final and binding. 123 (x)Contractors representative/Engineer will report to JE E/M in charge or AGE E/M at fore noon and after noon to collect routine/urgent works till completion of work. 124 Repair/Replacement ofstand alone HT Panel, 11 KV, 3 phase, 50Hz, 630A, 25 KA for 1 sec factory made, out door type cubicale fabricated out of CRCA sheet 3mm thick weather, dust and vermin proof, epoxy powder coated of IP-55 protection class with self contained air insulated compartment for bus bars and cable boxes with necessary support and 630A rated aluminium bus bar including cable galleries and provision of following switch gears including earthing switch, all pre-wiring with PVC copper conductor cable of suitable size including taking down of the unserviceable panel all as specified and as directed as per the below details :- 125 (a)Manually operated air break, load break switch alongwith earth switch and fuse trip mechanisum of HT HRC fuse - 50A, 230 V AC, Trip Coil and Aux Contact 2 No + 2NC. 126 (b)Space heater with ON/ OFF switch 10A, 230V AC. 127 (c)Emergency trip push botton - 01 128 (d)Cubicale illunination lamp with holder - 01 129 (e)Door limit switch, 230V AC. 130 (f)Provn of MCB, DP, 10A for control wiring. 131 (g)Provn of surge arrester 9 KV, 10 KA. 132 (h)Provn of thermostat 133 (j)Provn of indication lamp for LBS ON/ OFF, LBS E/S ON/ OFF 230V AC.Make of LBS shall be as mentioned in list of makes (PS). 134 S & F in repairsSurge arrester 9 kv /10 KV suitable for LBS ,RMU,VCB complete all as specified and as directed 135 Repair /Maint of old LT/HT Panels damaged doors,hinges ,indication Lamp RYB incluing welding work ,Power coating and lock and key complete all as directed 136 S&F MCCB, 4 Pole, 250 Amps, Thermal Magnetic Release adjustable type, 415 Volt, 36 KA including connecting up using suitable size of copper lugs including taking down existing one complete all as specified and as directed. Make : L&T, Legrand, Siemens 137 Material and labour for finding faults of HT under ground cable XLPE 11 KV of any size up to 185 Sqmm by using computerised / primary current injection method /any other method and locating fault .Cutting removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site completeNote:-(i) Excavation earth work sand cushioning PCC coveretc will be measured and paid separately under relevant items of schedule here in after. (ii) Cable jointwill be measured and paid separately.(iii) Additional length of cable required at site for jointing will be measured and paid separately 138 Dehydration/Filteration of HV grade Transformer oilof transformer/switch gears minimum three cycles to achievedielectric strength not less than 40 KV for 1 minute with 2.5 mm Gap as per IS 335-1983 for HVgrade including topping up with new transformer oil complete all as specified and as directed 139 Note for Item No 61:-(i) Centrifuging Machine with all T & Pand testingmachine of oil, required for dehydration shall be arranged by contractor 140 (ii) Oil required for topping up the transformer will be measured & paid separately. 141 Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore medium grade including necessary Excavation in any type of soil, Returning, Filling and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed. 142 Note for item No 62 :-(a)All Joints should be joined by Exothermic Welding or Brazing. 143 (b)The rate of earthing strip upto 7.5 mtrs shall be included in the quoted rate and beyond 7.5 mtrs shall be measured and paid separately. 144 (c)After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. 145 (d)Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. 146 (e)After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained. 147 S & F in repairs Galvanised Earth Strip of size 32x6mm as earthing lead fixed to wall/roofs etc all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing. 148 Supply and fixingLT, Bushing insulator with brass spindle, nuts, check nuts & washers etc suitable for outdoor type trasformer of capacity upto 250 KVA including taking down u/s from the transformer complete all as specified and as directed 149 Supply and fixing LT, Bushing insulator with brass spindle, nuts, check nuts & washers etc suitable for outdoor type trasformer of above 250 KVA upto 500 KVA including taking down u/s from the transformer complete all as specified and as directed 150 Supply and fixing Breather assembly suitable for outdoor type transformerwithsilica Gel including taking down u/s from the transformer complete all as specified and as directed 151 Supply & filling silica gel inside breather assembly of trasformer complete all as specified and as directed 152 Repairing, overhauling, Servicing & testingof Air circuit breaker, 440V, 630 Amps to1600 Amps, 50 KA, 3 Phase, 50 Hz, AC Supply system,for trouble free operation,and draw out type Air Ciruit breaker including the following works complete all as specified and directed:- Makes ofACB :- C&S, Schneider, Siemens. Location - MAFI PS 1, Sub Stn B & D, Mehra Sub Stn, Simulator bldg, Avionic Eqpt bldg, EW block, ETB bldg, Electric logistic block, IFCS section, Mech CENGO section, Near LCA Hanger 153 Note for item No 68 :-(a)The rate for following shall be deemed to be included in quoted rate. 154 (b) The entire job shall be carried out through the authorised service engineers of the OEM only. 155 (c) Servicing of Spout insulators safety shutter for effective covering by automatically open/close while draw in/draw out operations. 156 (d)Servicing of Breaker with motor charging asembly including motor and control switches having standard safety interlocks and locking facilities, mechanical operating connector lever and extendable rails to easily draw out/in the ACB trolly from the panels. 157 (e) Servicing of Mech/ elect inter locking system. 158 (f)Checking and tightening control wiring and rectifying the defects if any. 159 (g) Servicing of Mech (caster lock) and elect inter locking system. 160 (h) Checking and tightening control wiring and rectifying the defects if any. 161 (j)Replacement of PTFuse 162 (k)Replacement of unserviceable spare parts will be measured and paid for separately. 163 (l)Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quotrd unit rate. 164 (m)Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately. 165 Supply only spring charging assembly including motor 230 V AC operated all as directed. 166 Supply only Electrical closing coil 230 volt AC operated all as directed. 167 Supply only Electrical shunt trip coil 230 volt AC operated all as directed. 168 S & F In repair LT, Air circuit breaker, operational voltage 415 to 660 volts, insulation voltage 1000 volts, AC, 50 cycles, 3 phase, 4 pole, Manual draw outtype, rated current rating 630 amps and of breaking capacity not less than 50 KA with quick make, quick break, with manual operating mechanism complete with triple mound current transformer, Microprocessor based over current stop less release and static trip release, adjustable short circuit release, earth fault release with shunt trip with indication under voltage release and wired for indicating “Trip Healthy circuit” ancillary switch etc complete over load release rating400 to 800 Amps - 1 No including taking down existing one complete all as specified and as directed. Make : L&T/ Schneider/ Siemens/ABB 169 Repairing, overhauling, Servicing & testing of RMUs, 11 KV, 20 KA, 3 Phase, 50 Hz, AC Supply system, outdoor type for trouble free operation, consisting of one/two incomming and one/two outgoingwith SF6 gas filled VCB/ LBS/Fuse units, metal clad totally enclosed free standing floor mounted, non draw out type includingthe following works complete all as specified and directed. Make of RMU : ABB (Note : The Work shall be carried out through the authorised service engineers of the OEM only)(a) Servicing of Manual operated, 11kV, three position load break switch with snap-action knife blade mechanism along with associated earthing switch (ii) Servicing of true position mechanical indication of switch position ON, OFF and EARTH on the front facia of the panel for proper indication (b) (e)Checking and tightening control wiring and rectifying the defects if any. 170 Supply, erect, Testing & Commissioning of Master trip electro mechanical relay, Single element high speed tripping relay with hand rest contacts.1/4N V,HR contacts complete control wiring with material, Programming/setting/calibration including softwareof relays required for CB proper operation and necessary addition/alternation of panel alongwith dismantling of old unserviceable old type of relay Make- ALSTOMorits techno commerical equivalent ABB/Scheinder /Siemens 171 Supply, erect, Testing & Commissioning of numerical directional Over Current & Earth fault relay,Directional power, residual/negative over voltage, under/over voltage, directional over current ,under/over frequency,CB fault detection, VT/CT supervision, all rms measurments: Model P3U30 incoming breakers as directed & specified ,complete M&L forcontrol wiring with material, Programming/setting/calibration to be done by OEM including softwareof relays as required for CB proper operation and necessary addition/alternation inpanel alongwith dismantling of old unserviceable old type of relay shall be deemed to be included in quoted rate.Make- Schneider orits techno commerical equivalent ABB/Semiens 172 M&L for calibration as directed& recommendedof all type of exisitng numerical relays/transformer protectionwith OEM recommended programmable settings,rewiring of control wiring,including all necessary elements for completeion of job all as specified and directed. 173 M&L for making of notice board/disply board by using foarm sheet with given letters, data etc red and blue colour letters including screws and paste in different sizes all as specified and directed by Engr-in-Charge. 174 M & L in replacement of signboard made out of SS frame and size of 1.5 Mtr x 1 Mtr box type withfine quality PVC sheet writing letter minimum letter size is 10 and 30 ltrs placing in side board with proper securing and fixing one 20watt LED tube light with control wiring from switch point all as specified and directed by Engr-in-Charge 175 M & L Painting using heat resisting spray paint in two coats (one as finishing) over one coat of red oxide zinc chrome primer on external surface of HT panel/VCBs using Ist quality paint and applying through spray gun machine on specified working pressure incl writing of MES/SM No and other required data using different colour including writing letter in given size etc after removing/scrapping/rubbing to old fedded paint and filler filling etc complete all as specified and directed.(Note- Quoted unit rate shall be deemed included cost of writing letters & filling depresion by using putty, complete Colour & shade shall be approved by Engr-in-charge)(Make- Asian/Berger/Dulex)
Contract Date: Sep 28, 2025 Contract Value : 44.83 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
48.
Power #8013882 AOC
Tender For Biennial Rate Contract For Engagement Of One Agency For Various Day To Day Jobs Related To Ktps Testing Department- 1 Various day to day work of TST(Testing) 2 Relay & Control Circuit Checking 3 Thermal O/L relay Testing Assistance 4 Electromagnetic Relay coil / contactChanging. 5 Electromagnetic relay Testing Assistance 6 Numerical relay Testing Assistance 7 Ammeter/voltmeter selector switchchecking and replacement 8 6.6 kV/415 V CT/PT checking 9 Panel Switches(TNC/NIT/OFF/ON etc.)checking and replacement 10 Digital Meter checking 11 WTI / OTI guage checking and calibration 12 Panel Indication Lamp checking andreplacement. 13 Ammeter /Voltmeter checking andreplacement 14 GRP panel Checking & Testing assistance 15 GCD Panel Checking &Testing assistance 16 FBT panel Checking & Testing assistance 17 DAVR Checking & Load Testing assistance 18 Switchyard / Powerhouse Transformer yardPower Transformer Testing assistance 19 Transformer Oil BDV Testing Assistance 20 Transformer Oil Tan Delta Testing Assist 21 Transducer circuit checking 22 6.6 kV/415 V CB Testing Assistance 23 6.6 kV /415V Oil type transformertesting assistance 24 6.6 kV /415V Dry type transformertesting assistance 25 Switchyard CT/PT/CVT Testing Assistance 26 Switchyard LA Testing Assistance. 27 Switchyard CB Testing Assistance. 28 Switchyard ISOLATOR Testing Assistance. 29 Generator SCC/OCC Testing Assistance. 30 Numerical Relay Fixing, Mounting, wiring 31 Electromagnetic Relay Fixing, Mounting,wiring. 32 Analog/Digital meter Fixing, Mounting,wiring. 33 Transducer Fixing, Mounting, wiring 34 Panel cutting,welding for relays,meters 35 Single Cable Ferruling,lugging,terminateincluding dressing 36 Inter panel wiring including dressing 37 415V Motor Testing assistance 38 6.6 KV motor Neutral CT cabledisconnection/connection. 39 6.6 KV motor testing includingTan Delta Testing assistance 40 6.6 kV cable/bus bar Testing assistance 41 HV Testing assistance of Bus Duct/Power cable 42 Station Earthing System Testing 43 DC earth fault Checking 44 CT/CVT JB Dismantling & Replacementfor 400/220/132 kV Switchyard 45 CT/CVT JB Painting for400/220/132 kV Switchyard 46 CT/CVT JB Repairing /Fabricationfor 400/220/132 kV Switchyard 47 Optical fibre cable laying 48 Ethernet/LAN cable laying 49 Optical fibre cable splicing & terminate 50 Ethernet cable termination
Contract Date: Sep 20, 2025 Contract Value : 25.10 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
50.
Heavy Industries and Public Enterprises #7839569 AOC
Tender For External Electrification Work And Fire Fighting Works For Building No-10 (Plot No-13), Sector-28, Yea. Wc-E M-02 - 11kV Ring mains Unit (OUTDOOR TYPE) 3 Supplying,Installation, Shifting, Testing & Commissioning of11kV CT2T2 outdoor type Ring Mains Unitmade of galvanised iron, 3.0 mm thick CRCA steel sheet enclosed mounted on hot deep Galvanized , ISMC channel, IP 54 Protected & IP23D tested, proper ventilated and thermal class K10, with interlocked arrangement, with proper shade of paint and arcing withstand test of 20 kA for 1 sec. consisting of following as per specification complete as required: 4 3 way Ring main Unit (RMU) FBX- C/12-21/ CT2T2 consisting of 1No 630amp load break switchs and Two no 630 amp tee-off with SF6 circuit brakeras per specification with following : 5 Incoming – 1No. incommer each consisting offollowing 6 Machnical ON/OFF/EARTH indication. 7 Earthing switch 8 Machnical ON/OFF/EARTH indication. 9 Cable testing facility without opening the cable comparthent and without connecting the cable terminations. 10 Set of ON/OFF/EARTH semaphore indicating . 11 Live cable Indicating LEDs energized thru capacitive voltage dividers. 12 Right angle boots (Push on type) 13 Suitable space for termination of 1 No. 3 C x 185 sq.mm XLPE cable. 14 800A CU Main horizontal busbars (Inside Tank)Bus bar. 15 Outgoing Feeder 2 No. each consisting of following for 630kVA Transformer : 16 630 Amps manually operated fixed type SF6 Gas Insulated Circuit Breaker and earthing switch with full making capacity at 50 deg.C ambient and 100% humidity. 17 Earthing switch ,,aux contact for switch, 18 Anti reflex operating handle 19 Set of ON/OFF/EARTH semaphore indicating . 20 230Volt Shunt Trip coil for external tripping 21 Three over current and earth fault IDMT Microprocessor base self poweredRelay with instantaneous high set element. 22 8 Window alarm annunciators panel with hooter, push buttons, aux. Contactors etc as required as per specification. 23 Digital Ameter in built selector switch with 3No. CTS 24 Digital Voltmeter in built selector switch with protection fuse 25 Right angle boots (Push on type) 26 voltage presence indicator,Emergency trip Push Button,Aux contacts for breaker, relay trip coil, shunt trip coil,SELF-POWERED RELAY for 50/51/50N/51N,CURRENT TRANSFORMER FOR PROTECTION BUSHING TERMINALS, FAULT PASSAGE INDICATOR, BATTERY,BATTERY CHARGER,TRIVECTOR METER,PHASE INDICATING LEDs,HERMOSTAT,SPACE PANEL HEATER,AUXILLARY TRANSFORMER,MASTER TRIP RELY,TRIP CKT SUPERVISION RELAY,DOOR LIMIT SWITCH,VOLTAGE MONITORINE RELAY, 8 windoe annauncitor, Hooter etc complete as required 27 11KV H.T. Panel(IOCG ) 28 Supply, Installation, Testing and Commissioning of 11KV Indoor Floor mounted, Metal Clad 11 KV, VCB Panel with alu-zinc / GI enclosure with 4 Nos VCBs, totally enclosed & Fully interlocked horizontal drawout, vertical / horizontal isolation type breaker, dust and vermin proof, free standing, having capacities as mentioned below, single break, trip free mechanism, motorised charged and auto-cum-manual closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C supply with short circuit fault level of 500MVA, complete with self contained, fully interlocked , rack in rack out mechanism, air insulated but encapsulated copper bus bars of 800 A capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiilary switch of 4 NO + 4 NC and equipped with following switch gears and accessories etc. andsuitable for connecting 3 core 300 Sq.mm XLPE 11 KV cable heat shrinkeable end termination (Cable entry from Bottom ) etc as required. 29 Incomer-1 No. VCB Panels each having the following 30 (a) 1 No. 630A, 11KV, 3 phase, 50 Hz Vacuum Circuit Breaker 31 (b)1 No 3 phase 11 KV/110 Volts PT, class 0.5 accuracy and 100 VA burden with 1 No Voltmeter (0-15 KV), Digital type, selector switch for voltmeter and protection fuses for HT metering upto 12 KV on incomer 32 (c)1 set of dual core 3 CTs 200/5+5A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection 33 (d ) 1 No – multi function meter suitable for operation on 110V a.c supply with RS-485 interface for integration to BMS 34 (e ) 1 No - Digital Tri Vector Meter (Trivector meter shall have communication features for monitoring by BMS) 35 (f) 1 No. Microprocessor based numerical relay for Over current and Earth fault protection 36 (g) 1 set of phase indicating lamps with HRC fuses 37 (h) 1 set of indicating lamps to indicate OPEN, CLOSE, TRIP, SPRING CHARGED, TRIP CIRCUIT HEALTHY 38 (i)6300Amps copper busbar-1 set (common) 39 (j)Test terminal block 40 (k)Trip/Neutral/close switch 41 (l) 1 set of copper bus bar for earthing (common) 42 (m) 1 set of master trip relay & trip circuit healthy supervision relay. 43 (n) Provision for padlocking the incomer VCBs in OFF position. 44 11KV H.T. Panel incomer cum outgoing Panel) as above & as per SLD 45 COMPACT SUBSTATION-1000KVA 46 Supplying, assembling, erecting, connecting, testing and commissioning of 11 KV Compact Secondary Sub Station outdoor type designed for natural cooling having type tested equipment comprising distribution transformers, SF6 insulated compact switchgear having metal enclosed robotically sealed/welded stainless steel tank , low voltage switchboard, interconnection between HT switchgear & Transformer using single core cables and Transformer to LT switchgear using Al bus bars/Cables factory built / ready for connection type,otherassociated equipment etc including necessaryfoundation and earth work etc. without oil pits complete as required conforming to detailed specification laid down in the tender documents. The enclosure shall have modular construction using 2mm thick CRCA and 4 mm thick got dipped CRCA sheets for base and shall be painted with polyurethane paint from the exterior.The enclosure for LT switchgear & HT switchgear shall be provided with IP54ingress protection. The transformer compartment will have IP34 ingress protection. Note- HT & LT Switchgear should besame make. 47 The transformer used shall be specially designed for low losses (As per IS:-1180 level-01) and shall be hermetically sealed oil immersed& with corrugated tank, oil level indicator, hermetic protection realy, pressure relief device, gas filling valve, oil temprature indicator, multi function relay (DGPT Device) etc. as required Complete in all respect.The earthing shall be suitablefor 18.3KA fault current.The varoius combinations of CSS shall be as per details below including necessaryfoundation and earth work etc 48 HT Switchgear Section 49 11KV 3 Way RMU( CCT2) type Compact switchgear unit having 2 No. Isolater load break switches and1 No SF 6 circuit breaker enclosed in robotically laser welded non-extensible type stainless steelSF6 enclosure with Self powered relay (IDMTL O/C + E/F ) as HT switchgear as per the requirement detailed in the tender documents/SLD. 50 Copper bus bars of 800 A capacity for HT 11 KV network. 51 Transformer Section 52 11KV/415V,1000KVA, hermetically sealed oil immersed Transformer suitable for CSS as per detailed specifications, with Automatic on load tap changer & RTCC .Remote tap changer circuit (RTCC) panel with all associated accessories as per schedules and specifications.Taps on HV for HV variation : +5 to - 15 % in the steps of 1.25 with AVR. 53 LV Switchgear Section 54 LT section comprising the following & as shown in the drawing: 55 1600Amps 415V, 4P, 50Hz, 50KA Manual operated drawout type Air Circuit Breaker (ACB) with overload and short circuit Protection. 56 RELAYs, METERING INDICATOR & CTs 57 On/Off Indication lamps with 6A control MCB as per fault requirement 58 R,Y,B phase Indication lamps with Control MCB as per fault requirement. 59 One Set of 5 Nos. indication panel each with 6A control MCB as per fault requirementwith ACB 60 1 No. off delay timer for manual operation. 61 Phase Reversal relay 62 8 Window annunciator all compartment 63 Heat shrinkable cable end terminal indoor type cable box 240/300/400 Sq. mm. Size complete all as required to connect incoming and outgoing HT cables to unitized Sub-Station and interconnection of network within the unitized Sub-Station with arc proof shoes. 64 COMPACT SUB-STATION-1000KVA AS DESCRIBED ABOVE 65 H.T. Cable 66 Supplying of following size of Al conductor, XLPE insulated armoured and over all PVC sheathed, 11 KV (E) grade earthed cable as per technical specifications 67 3 core x185Sq. mm YEIDA SOR-2(B) 68 HT Cable laying 69 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 70 3C X185 Sq. mm YEIDA SOR 4(G) 71 S/L of 200mm dia. H.D.P.E. pipe for drawing of power cable across the road by drilling of 220mm dia. at 1mtr. below the road level thereby doing the work of providing H.D.P.E pipe by manual Trenchless method.PE-63/PN-8 complete in all respect, as directed by Engineer in charge YEIDA SOR-23 72 S/F of 11kv HV insulating mats confirming to IS 15652-2006. The mats should have been type tested by CPRI or another third party lab of equivalent stature. The mats shall be moisture proof, fire retardant and resistant to acids, alkalies & transformer oil. Complete in all respects as per direction of the Engineer-in-charge. YEIDA SOR-59 73 Supply and fixing in position the approved “Shock Treatment Charts” written in English and Local Language. These charts shall be framed in teak wood frame and covered with glass. 74 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 75 Supply and fixing position the approved single line diagram framed in 1000 x 100 mm size glass frame and installed in main LT Panel Room. 76 Supply of tool kit, first aid box with all accessories required for operation and maintainence for 415 volt & 11 kV equipment with 1 pair 11 kV rubber hand gloves of approved make. 77 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. 78 SUBHEAD-II-DIESEL GENERATOR SETS 79 FOR - BUILDING NO- 10 80 Supply, installation, testing and commissioning of Prime Duty, Diesel engine driven generating Set (Silent Type) of 1010KVA capacity CPCB-IV compliance to ISO-8528-Part 1 with Genset Controller (DIEF / DeepSea / Woodward or eq) and comprising of following:- 81 The DG Set emission should be as per revised CPCB-IV norms as per the latest notification MOEFCC NOTIFICATION “GSR 804(E) DATED 03.11 .2022 [F.NO. Q-15017/05/2012-CPW 82 a) Diesel Engine 83 Engine developing minimum1010kVA Gross Engine Power at 1500 RPM rated for Prime Duty with an additional 10% overload capacity for one hour in period of twelve hours of continuous operation at standard operation conditions as per ISO 3046-1/1, ISO 15550 inclusive of all standard accessories like Silencer, After Treatment System In Front of Radiator, High Pressure Common Rail (HPCR) Fuel Injection, ECU control providing efficient performance in terms of power & fuel consumption, Electronic Governing of G3 Governing Class and with all standard accessories as per ISO:8528-5.Engine Cooling System must be designed for 50⁰C ambient 84 b) Alternator 85 Synchronous alternator 1010KVA, AC 3 phase, 415 volt, 50 Hz, 1500 RPM, 0.8 lagging power factor alternator shall be in SPDP enclosure, self excited, self regulated, foot mounted with end shield. The alternator shall confirm to IS:13364/IEC 60034 – 1 suitable for tropical conditions.Alternator shall deliver full output at 50 degree C, shall have inbuilt BTD and winding temp. detector along with space heaters. Necessary spaace provision for REF protection with separate earth fault CTs shall be provided inside alternator box. alternator should one heigher rating size for 50 degree amb. 86 c) Automatic Main Failure Panel 87 DG AMF control panel with internal access to facilitate both connection and maintenance complete with 1 No 1600Amps ACB WITH COPPER BUSBAR to loads. Ammeter, Voltmeter, frequency meter, Kh meter etc. including light Set ON/OFF battery charge etc. complete in all respect with power loom between alternator & isolator panel thru CU flexible within the Genset Canopy / Acoustic Enclosure.Engine mounted instrument panel fitted with and having digital/Analog display. 88 d) Acoustic Enclosure 89 The enclosure fabricated from high grade cold rolled close annealed (CRCA) sheet and steel members lined with high density sound absorption material to reduce the sound level to 75 dBA from the original sound level measured at a distance of 1 meter away from the GenSet, under free field conditions compliance to CPCB- IV Noise limit / guidlines for Dg Set below 1000kVA / 800Kwe. Accoustic and weather proof enclosure suitable for the DG Set with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per CPCB-IV norms.The enclosure will be provided with durable industrial locking system with doors duly gas-keted etc., all complete with ARAI Type approval / certification. 90 e) Battery 91 2x12V, 150 Ah Battery assembly with all necessary connecting leads and terminals of reputed make and stand for lead acid Maintinance free battery. Starter Motor Power must be min 8KW 92 f) Base frame 93 Skid mounting type base frame fabricated from suitable size of MS channel / CRCA Sheet providing common bed for engine & alternator directly coupled together with AVM Pads and necessary reinforcement which shall be installed on suitable RCC foundation and vibration isolation arrangement as per recommendations of manufacturer. 94 g) Testing in Works / Factory 95 The DG sets will be tested in the works of the manufacturer for 12 hours at full load including 10% over load before dispatch in the presence of the representative of client . Testing will be crried out as per CPWDs specifications. 96 h) MISC 97 Inbuilt Capacity Day tank of standard capacity . for fuel storage with level markings inside and outside canopy. 98 After Treatment System In Front of Radiator with DEF (diesel exhaust fluid) / AdBlue storage tank of min 35L for urea dosing with proper connection etc. 99 SITC of TP,1600A, Electrical Fix ACB Isolator Panel Outside Canopy with IP4x suitable for Indoor application. Power Cabling b/w DG Set & Isolator Panel included and thes ameneeds to be done at site by electrical contractor. YEIDA RATE- 4.02 100 DG SET 1010 KVA AS PER DESCRIBED ABOVE 101 EXHAUST PIPING 102 Supply and Fixing of MS Exhaust Pipe of dia 350mm class B for 1010KVA DG Set with rain cap. With all accessories etc., complete 103 Supply and fixing of Thermal insulation on MS Exhaust Pipe of dia 350mm class B for 1010 KVA DG Set with 50mm thick LRB/Rock Wool of 96 Kg density per cub mtr. Covered with wire mesh & covered with 24 gauge AI Sheet 104 Supply,testing and commissioning ofAluminium cladding for residential silencerswith LRB Rockwool 50mm Thick, density 64 Kg/cu.mtr., wire mesh and 24 gauge aluminium cladding. complete as required suitable for 1010 Kva DG exhaust pipe temperature upto 450°C. 105 Supply and installation of SS Flexible Bellows, 8 dia. (350 mm NB), complete with counter flanges, heat resistant gaskets, nuts-bolts-washers etc., complete as required. 106 Providing & fixing for MS support structure for exhaust fume pipes from DG Sets (Exhaust pipe to be measured and paid for separately) along horizontal and vertical runs upto the height (as per CPCB norms) including cutting, welding etc and applying two coats of red oxide and two coats of synthetic enamelled paint of colour and shade as directed by client/Architect. The design of the support structure shall be done by the contractor and shall be as per CPCB norms approved , also to get the approval from the consultant before execution etc. as required. 107 Provide & fixing fuel piping with pipe supports, bends, flanges packing, hardwares and painting from main storage tank to day oil tank and day oil tank to DG Set of following sizes 108 25 mm dia Heavy duty (Class C ) MS Pipe 109 VALVES 110 Supply & fixing the following valves of approved make complete with flanges, bolts nuts and gaskets etc., 111 25mm dia gate valve 112 Supply & fixing of 990 Litre (14 SWG thick) fuel oil service tank with oil level indicator with level gauge scale, inlet/outlet connection valve, air vent, pedestal for mounting etc., including 02 Nos if hand fuel transfer pumps 113 Obtaining necessary approvals from the chief electrical inspectorate, if required for electrical safety for 1X 1010kVA Genset. 114 SUBHEAD-III- 15 KVA UPS 115 Supply, installation, testing and commissioningof IGBT Rectifier & Inverter basedUPS system comprising of 1 no 15 kVA units with batterybank backup of 30 minutes duration for full load with all standards fittings, accessories, protection, instruments, indications and controls including but not restricted to transformer, rectifire, inverter, SMF battery with float cum boost battery charger, static bypass switch, maintenance bypass, output isolation transformer, interconnections etc.including warranty and free all inclusive comprehensive maintenance services for two years for UPS and battery bank after the date of handing over complete as per specification and as required.YEIDA RATE - 45.03 116 SUBHEAD-IV-LTPANEL& DISTRIBUTION BOARD 117 Supply,Installation, Testing and Commissioning of dust, damp and vermin proof IP- 4X / 5X free floor standing /wall mounted, Indoor type, form 3B/4A complied factory assembled in sheet steel enclosed modular construction, extendable from both side, fabricated out of CRCA grade d or equivalent sheet steel for load bearing member in 2mm thick and 1.6mm for non-load bearing members and doors with covers, 3mm thick for gland platescomplete with 9 tank pre treatment process for powder coating with minimum 80 to 100 micron electro static powder coating coverage in approved shade of RAL 7032/7035 in elasto polymer type powder, complete with Aluminium bus bars designed for proper temperature rise withstand capacity, inter-connection with copper conductor wires / aluminium strips, neutral links, earth bus etc. including control wiring with 1.5sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, cable alleys, cable gland plates in two half for acb panels, etc. suitable for operation on 415 ±10% volts, 50 Hz AC 3 phase 4 wire system necessary metering protections & indications and mounted with the following switch gears etc. complete as required complying with IEC-61439 Part1&2 . 118 (Each MCCB will have variable current setting for over current and short circuit, front extended lockable handle, pad lockable in off position, indication light for ON, shrouding on incomer side, termination shall be suitable for aluminium bus bars. All MCCBs shall be microprocessor based only otherwise as specified in the boq. 119 All Switchboards shall have provision for entry of cables from the top or bottom as required 120 All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars shall be fully insulated with heat shrinkable sleeves and should withstand busbar temp. The busbar support insulators should be SMC. Padlocking isolating switches and load break switches lockable in OFF position. The panel shall meet criterias as per Client EHS guideline. 121 All kA ratings indicated shall be Ics = Icu = Icw values 122 Ics value should be 100% 123 GA drawings shall be got approved from Owners/Architects/ Consultants before fabrication. 124 Tube based Clean Agent Fire suppression systemshall be taken for all panels as specified in the boq. 125 All Panel should be Form 4b (For ACB Compartment) &3b combination. 126 MAIN L.T PANELIcs = 50KA 127 Incomers :- 3 Nos numbers (2 x 1600A, 4P EDO ACB from CSS + 1 x 1600A 4P EDO ACBDG. 128 Incomer from CSS of 1010 kVA 129 2 Nos.1600A 4P EDO ACB with microprocessor based communicable release, over current with different time settings, short circuit with time delay & earth fault release with time delay, instantaneous current setting . Suitable links shall be provided for cable termination. ON/OFF/TRIP indication shall be wired through potential free contact up to terminal strip of breaker for hooking to BMS. Each incomer shall have following. 130 1 no. 0-500V 96 sqmm digital voltmeter with selector switch, 3 No. phase indicating lamps to show the incoming power with control 2A TP MCB. 131 3 Nos. indicating lights for ACB on/ off/ trip position. 132 1 No.phase reversal relay with matching cast resin CTs 133 1 no. 3 phase voltage monitoring relay cum phase sequence meter 134 1 No. APFC relay with matching cast resin CTs. 135 Incomer from DGs 136 1No. X 1600A 4P EDO ACB with microprocessor based, over current with different time settings, short circuit with time delay & earth fault release with time delay. Suitable links shall be provided for cable termination. ON/OFF/TRIP indication shall be wired through potential free contact up to terminal strip of breaker for hooking to BMS. Each incomer shall have following. 137 This release shall have RS-485 including showing all parameters on the software before integrating to IBMS 138 1 no. 0-500V 96 sqmm digital voltmeter with selector switch, 3 No. phase indicating lamps to show the incoming power with control 2A TP MCB. 139 3 Nos. indicating lights for ACB on/ off/ trip position. 140 1 No. ON/OFF push buttons. 141 1 No. reverse power relay with matching cast resin CTs 142 1 no. 3 phase voltage monitoring relay cum phase sequence meter 143 Bus Couplers 144 One number 1600A 4 pole EDO ACB microprocessor based over current, short circuit release type as bus coupler. Necessary contacts shall be wired upto terminal strip for breaker ON/OFF/TRIP, providing potential free contact ON/OFF/TRIP for status monitoring in BMS. 145 Bus Bar Section-I & II 146 Two set ofTPN Aluminium bus bar rated for 2000A (after considering all necessary deratings) 3 phase 4wire, 50Hz. A minimum derating factor of 0.80 must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ. current density of bus-bars shall not be more than 0.8 Amps/sq.mm for Aluminium and earth bus size shall be suitable of system fault level. 147 Outgoings Sections 148 4 Nos. 800A 4P feeder each having one no. 800A 4P EDO ACB 149 3 Nos. 500A 4P feeder each having one no. 500A 4P MCCB. 150 2 Nos. 100A 4P feeder each having one no. 100A 4P MCCB 151 5 Nos. 63A 4P feeder each having one no. 63A 4P MCCB 152 Other items such as 153 PLC for Necessary electrical Interlocking through advance contacts / contactorsin MCCB/ ACBs (Incomers & Bus couplers)should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed & as required. 154 Panel with auto and manual operation and Load Manager for both Mains and DG power, whose function will be to determine the Load. Supplier to submit the Bill of materials for the above functions also provide motorised potential meter for each generator for voltage correction. 155 1kVA online UPS with minimum 15 minutes backup built in battery for PLC system. 156 1 Lot of control wiring. 157 1 Set of designation plates 158 Tube based Clean Agent Fire suppression systemshall be taken for panels. 159 MAIN L.T PANEL as describe above and shown in SLD. 160 BUILDING PANEL-01 Ics = 35KA 161 Incomer:- 162 2Nos. X 800A 4P EDO ACB with microprocessor based, over current with different time settings, short circuit with time delay & earth fault release with time delay. Suitable links shall be provided for cable termination. ON/OFF/TRIP indication shall be wired through potential free contact up to terminal strip of breaker for hooking to BMS. Each incomer shall have following. 163 1 no. 0-500V 96 sqmm digital voltmeter with selector switch, 3 No. phase indicating lamps to show the incoming power with control 2A TP MCB. 164 3 Nos. indicating lights for ACB on/ off/ trip position. 165 1 No.phase reversal relay with matching cast resin CTs 166 1 no. 3 phase voltage monitoring relay cum phase sequence meter 167 Bus Bar 168 One set of TPN, AL. bus bar rated 1000Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 169 The outgoing feeders are as follows : 170 3 Nos. 200A 4P feeder each having one no. 200A TP MCCB. 171 4 Nos. 160A 4P feeder each having one no. 160A TP MCCB. 172 Tube based Clean Agent Fire suppression systemshall be taken for panels. 173 1 set of complete wiring 174 Necessary electrical Interlocking through advance contacts / contactorsin MCCB/ ACBs (Incomers & Bus couplers)should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed & as required. 175 BUILDING PANEL-01 Ics = 35KA as describe above and shown in SLD. 176 BUILDING PANEL-02Ics = 35KA 177 Incomer:- 178 2Nos. X 800A 4P EDO ACB with microprocessor based, over current with different time settings, short circuit with time delay & earth fault release with time delay. Suitable links shall be provided for cable termination. ON/OFF/TRIP indication shall be wired through potential free contact up to terminal strip of breaker for hooking to BMS. Each incomer shall have following. 179 1 no. 0-500V 96 sqmm digital voltmeter with selector switch, 3 No. phase indicating lamps to show the incoming power with control 2A TP MCB. 180 3 Nos. indicating lights for ACB on/ off/ trip position. 181 1 No.phase reversal relay with matching cast resin CTs 182 1 no. 3 phase voltage monitoring relay cum phase sequence meter 183 Bus Bar 184 One set of TPN, AL. bus bar rated 1000Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 185 The outgoing feeders are as follows : 186 3 Nos. 250A 4P feeder each having one no. 250A TP MCCB. 187 3 Nos. 160A 4P feeder each having one no. 160A TP MCCB. 188 1 No. 125A 4P feeder each having one no. 125A TP MCCB. 189 Tube based Clean Agent Fire suppression systemshall be taken for panels. 190 1 set of complete wiring 191 Necessary electrical Interlocking through advance contacts / contactorsin MCCB/ ACBs (Incomers & Bus couplers)should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section as per single line diagram enclosed & as required. 192 BUILDING PANEL-02 Ics = 35KA as describe above and shown in SLD. 193 COMMON PANELIcs = 35KA 194 Incomer 195 1 No. Incomer 160 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 196 Bus Bar 197 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 198 The outgoing feeders are as follows : 199 1 No. 125A 4P feeder having one no. 125A 4P MCCB . 200 7 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 201 2 Nos. 40Amps 4P feeders each having one number 40 Amps 4P MCB. 202 Tube based Clean Agent Fire suppression systemshall be taken for panels. 203 1 set of complete wiring 204 COMMON PANEL Ics = 25KA as describe above and shown in SLD. 205 METER BOARD-01 &03 (G.F&F.F )Ics = 35KA 206 Incomer 207 1 No. Incomer 200 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 208 Bus Bar 209 One set of TPN, AL. bus bar rated 250Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 210 The outgoing feeders are as follows : 211 1 Nos. 400MM (H) x 375MM(W) Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid duel source CT operated Energy Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 100A, MCCB, 25kA with 100A, connecters in cable alley and power wiring between meter and connector via MCCB. 212 6 Nos. 300MM (H) x 375MM(W), Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid Energy duel source Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 40A, MCB, 10kA with 63A, connecters in cable alley and power wiring between meter and connector via MCB. 213 2Nos. 40Amps 4P feeders each having one number 40 Amps 4P MCB. 214 Tube based Clean Agent Fire suppression systemshall be taken for panels. 215 1 set of complete wiring 216 METER BOARD-01 &03 (G.F&F.F )Ics = 35KA as describe above and shown in SLD. 217 METER BOARD-02&04 (G.F & F.F )Ics =35KA 218 Incomer 219 1 No. Incomer 160 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 220 Bus Bar 221 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 222 The outgoing feeders are as follows : 223 10 Nos. 300MM (H) x 375MM(W), Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid Energy duel source Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 40A, MCB, 10kA with 63A, connecters in cable alley and power wiring between meter and connector via MCB. 224 2 No. 40Amps 4P feeders having one number 40 Amps 4P MCB. 225 Tube based Clean Agent Fire suppression systemshall be taken for panels. 226 1 set of complete wiring 227 METER BOARD-02&04 (G.F&F.F )Ics =35KA as describe above and shown in SLD. 228 METER BOARD-05&07 (S.F & T.F )Ics = 35KA 229 Incomer 230 1 No. Incomer 200 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 231 Bus Bar 232 One set of TPN, AL. bus bar rated 300Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 233 The outgoing feeders are as follows : 234 1 Nos. 400MM (H) x 375MM(W) Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid duel source CT operated Energy Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 125A, MCCB, 25kA with 125A, connecters in cable alley and power wiring between meter and connector via MCCB. 235 1 No. 300MM (H) x 375MM(W), Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid Energy duel source Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 63A, MCB, 10kA with 63A, connecters in cable alley and power wiring between meter and connector via MCB. 236 1 Nos. 125Amps 4P feeders each having one number 125 Amps TP MCB. 237 Tube based Clean Agent Fire suppression systemshall be taken for panels. 238 1 set of complete wiring 239 METER BOARD-05&07 (S.F & T.F )Ics = 35KA as describe above and shown in SLD. 240 METER BOARD-06&08 (S.F&T.F )Ics = 35KA 241 Incomer 242 1 No. Incomer 250 Amps 4P MCCB with thermal magnetic releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 243 Bus Bar 244 One set of TPN, AL. bus bar rated 250Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 245 The outgoing feeders are as follows : 246 2 Nos. 400MM (H) x 375MM(W) Glass window compartment each with Lock & key arrangement including backelite sheet for mounting provided digital Three Phase pre-paid duel source CT operated Energy Meter with RS485 Port for BMS connectivity. Incuding providing and fixing of din channel monted 4P, 125A, MCCB, 25kA with 125A, connecters in cable alley and power wiring between meter and connector via MCCB. 247 1 Nos. 125Amps 4P feeders each having one number 125 Amps TP MCB. 248 Tube based Clean Agent Fire suppression systemshall be taken for panels. 249 1 set of complete wiring 250 METER BOARD-06&08 (S.F&T.F )Ics = 35KA as describe above and shown in SLD. 251 PRESSURIZATION PANELAT TERRACE (OUTDOOR TYPE)Ics = 25KA 252 Incomer 253 1 No. Incomer 63Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 254 Bus Bar 255 One set of TPN, AL. bus bar rated 200 Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 256 The outgoing feeders are as follows : 257 1 No. of 7.5 amp rating of TP MCCB of 50 kA breaking capacity with 2.2 KW DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required. 258 1No.7.5 Amps TP MCCB with DOL Starter .(Space only) 259 1 set of complete wiring 260 PRESSURIZATION PANELAT TERRACE (OUTDOOR TYPE)Ics = 25KA as describe above and shown in SLD. 261 COMMON AREA VRV PANEL AT TERRACE(OUTDOOR TYPE)Ics = 35KA 262 Incomer 263 1 No. Incomer 125 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 264 Bus Bar 265 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 266 The outgoing feeders are as follows : 267 2 Nos. 40Amps 4P feeders each having one number 40 Amps 4P MCB along with 40 4P ELCB (100mA). 268 4 Nos. 32Amps 4P feeders each having one number 32 Amps 4P MCB along with 40 4P ELCB (100mA).. 269 1 set of complete wiring 270 COMMON AREA VRV PANEL AT TERRACE(OUTDOOR TYPE)Ics = 35KA as describe above and shown in SLD. 271 PLUMBING PANEL Ics = 35KA 272 Incomer 273 1 No. Incomer 63Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 274 Bus Bar 275 One set of TPN, AL. bus bar rated 200 Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 276 The outgoing feeders are as follows : 277 2 Nos. of 12 amp rating of TP MCCB of 50 kA breaking capacity with 5 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required. (For Sump Pump -1working&1 standby). 278 2 Nos. of 10 amp rating of TP MCCB of 50 kA breaking capacity with 3 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required. (For Domestic Transfer Pump -1working&1 standby). 279 2 Nos. of 10 amp rating of TP MCCB of 50 kA breaking capacity with 3 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required. (For Flusing Transfer Pump -1working&1 standby). 280 2Nos. of 7.5 amp rating of TP MCCB of 50 kA breaking capacity with 2 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required.(For Flusing Booster Pump -1working&1 standby). 281 2No. of 7.5 amp rating of TP MCCB of 50 kA breaking capacity with1 HP DOL motor starter type iico-ordination along with TP power contactors (AC3) with inbuilt 2NO + 2NC contact with necessary additional potantial free auxiliary contactor oprate starter ON/OFF and remote switching, Red, Green & Yellow Indicating Lamps, Start/Stop Push buttons LED type, Auto/Manual/Off selector switch Complete as required.(1working&1 standby). 282 1No.32 Amps DP MCB 283 1 set of complete wiring 284 PLUMBING PANEL Ics = 35KA Ics = 35KA as describe above and shown in SLD. 285 320KVAR Capacitor PanelIcs = 35KA 286 320KVAR CAPACITOR PANELS (5X50 KVAR + 1X25KVAR + 3X10KVAR+ 3X5KVAR) 287 Supplying, installation, testing & commissioning of factory built floor mounted auto-manualpower factor correction system panel of 320KVAR capacity having 3 phase, Mixed Die Electric(total power loss not exceeding 0.50 W/ KVAR) power capacitor in eleven steps, filled with suitable oil and; provided with 10KVAR fixed capacity and balance Electronic Thyristor switching & detuned filters (min.7%) to supress switching of inrush current and reducing harmonics to improve capcitor life. 288 The system Shall be provided with required capacity master MCCB, to control its main operating parameters such as over loads, short circuit, etc. 289 The panel shall be fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, having 800 Amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 35 MVA for I Sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common GI earth bar of size 75 mm x 10 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears/ accessorieswith required size of Al. bus bars and control wiring with 2.5 sq.mm. PVC insulated FRLS copper conductor Single Core cable, of2 mm thick MS Sheet, provided with exhaust fans (with thermostat) and grills for proper ventilation, interconnections with suitable size conductor cables & lugs and accommodating the following swicthgears & accessories: 290 800Amp 3 Pole ACB- 1 No. 291 LED Indicating light - 12 Nos. 292 One numbers dual source, dual setting, binary typeautomatic power factor sensing and correction relay (12stages) complete with its all accessories etc. asrequired. 293 MCCBof following capacity with spreader link and phase barrier 294 125 A, 3P,MCCB - 5Nos. 295 63 A, 3P,MCCB - 1 Nos. 296 32 A, 3P,MCCB- 6 Nos. 297 L.T. Powerfactorimprovingcapacitor of indoortypesuitable for operation on415 volts AC 3 phase 50 Hzcomplete with bankingarrangement, interconnections with suitable size ofcopper conductor PVCinsulated PVC sheathedunarmoured cable, dischargeresistance etc. as required. 298 Bank of50 KVArrating -5 Sets 299 Bank of 25 KVAr rating -1 Set. 300 Bank of 10 KVAr rating -1 Set. (FIXED TYPE). 301 Bank of 10 KVAr rating - 2 Set 302 Bank of5 KVAr rating -3 Set 303 APFC Panel as described above and shown in SLD 304 OFFICE PANEL-1&5 AT S.F & T.FIcs = 35KA 305 Incomer 306 1 No. Incomer 125 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 307 Bus Bar 308 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 309 The outgoing feeders are as follows : 310 2 Nos. 100Amps 4P feeders each having one number 100 Amps 4P MCCB. 311 2 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 312 1 set of complete wiring 313 OFFICE PANEL-1&5 AT S.F & T.FIcs = 35KA as describe above and shown in SLD. 314 OFFICE PANEL-2,3&7 AT S.F & T.FIcs = 35KA 315 Incomer 316 1 No. Incomer 125 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 317 Bus Bar 318 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 319 The outgoing feeders are as follows : 320 1 Nos. 100Amps 4P feeders having one number 100 Amps 4P MCCB. 321 4 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 322 1 set of complete wiring 323 OFFICE PANEL-2,3&7 AT S.F & T.FIcs = 35KA as describe above and shown in SLD. 324 OFFICE PANEL-6 ATT.FIcs = 35KA 325 Incomer 326 1 No. Incomer 125 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 327 Bus Bar 328 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 329 The outgoing feeders are as follows : 330 2 Nos. 100Amps 4P feeders each having one number 100 Amps 4P MCCB. 331 2 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 332 1 set of complete wiring 333 OFFICE PANEL-6 ATT.FIcs = 35KA as describe above and shown in SLD. 334 OFFICE PANEL-4&8 ATS.F& T.FIcs = 35KA 335 Incomer 336 1 No. Incomer 100 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 337 Bus Bar 338 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 339 The outgoing feeders are as follows : 340 2 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB. 341 1 No. 40Amps 4P feeders having one number 40 Amps 4P MCB . 342 1 set of complete wiring 343 OFFICE PANEL-4&8 ATS.F& T.FIcs = 35KA as describe above and shown in SLD. 344 HVAC PANEL-1ATTERRACEIcs = 35KA(Outdoor Type) 345 Incomer 346 1 No. Incomer 100 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 347 Bus Bar 348 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 349 The outgoing feeders are as follows : 350 2 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB along with 63Amp. 4P ELCB (100mA). 351 1 No. 32Amps 4P feeders having one number 32 Amps 4P MCB along with 40Amp 4P ELCB (100mA). 352 1 set of complete wiring 353 HVAC PANEL-1ATTERRACEIcs = 35KA (Outdoor Type) as describe above and shown in SLD. 354 HVAC PANEL-2,3&7ATTERRACEIcs = 35KA (Outdoor Type) 355 Incomer 356 1 No. Incomer 100 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 357 Bus Bar 358 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 359 The outgoing feeders are as follows : 360 2 Nos. 40Amps 4P feeders each having one number 40 Amps 4P MCB along with 40 Amp. 4P ELCB (100mA). 361 1 No. 32Amps 4P feeders having one number 32 Amps 4P MCB along with 40Amp 4P ELCB (100mA). 362 1 set of complete wiring 363 HVAC PANEL-2,3&7ATTERRACEIcs = 35KA (Outdoor Type) as describe above and shown in SLD. 364 HVAC PANEL-5 &6ATTERRACEIcs = 35KA (Outdoor Type) 365 Incomer 366 1 No. Incomer 100 Amps 4P MCCB with microprocessor based releases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CTs. 367 Bus Bar 368 One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratingsof 80%) for phases and neutral for half capacity of phases. 369 The outgoing feeders are as follows : 370 3 Nos. 63Amps 4P feeders each having one number 63 Amps 4P MCB along with 63Amp. 4P ELCB (100mA). 371 1 No. 32Amps 4P feeders having one number 32 Amps 4P MCB along with 40Amp 4P ELCB (100mA). 372 1 set of complete wiring 373 HVAC PANEL-5 &6 ATTERRACEIcs = 35KA (Outdoor Type) as describe above and shown in SLD. 374 Design, Manufacture, Supplying, loading & unloading assembling at site, installation, fixing on the position, testing & commissioning of the following cubical type, dead front, 2.5mm thick sheet steel enclosed, 1600Amp, 4P, MDO, ACB-50kA, without protection relays in 2.5 MM Thick sheet metal enclosed Out door to be located near D.G Set, including emergency push bottom with key lock and provide 5 Nos indicating lamps for status indication ON,OFF , tripped due to fault, DC supply healthy and spring charged complete as required. confirm to degree of protectio IP:55. Also provide M.S. Stand made height 600mm. Maximim height of panel should not be more then 2000mtr. 375 S & F surface/Flush mounting 4ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. (For Lift). 376 S & F surface/Flush mounting 4ways V TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. (For UPS O/P) 377 S&F of 80 to 100 Amp 4 pole MCCB (16 KA) Thermal Magnetic release (For UPS O/P DB Incomer) 378 S&F of 63 Amp. 4 pole MCB(10 KA) C Curve (LIFT DB ICOMER) 379 S&F of 6 Amp. to 32 Amp. TP MCB (10 KA) C Curve ( For UPS O/PDB & LIFT DB Outgoing ) 380 S&F and making connection of 40 Amp. 4 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. (For Lifts) 381 Prepaid Meters 382 Supply , Installation & Commissiong of Dual source- 3 Phase, BIS-13779,BIS 15884 approved, class-1,Static meter 10-60Amp, including software license with RS 485 communication protocols and load manager including thimbling of power and control cables. Metere display show all the basic electrical parameters (V, A,KW,KVA,P.F, KWH / KVAH ).Model No. PE5120 383 Supply , Installation & Commissiong of Dual source- 3 Phase, BIS-13779,BIS 15884 approved, class-1,Static meter ct operated , including software license with RS 485 communication protocols and load manager including thimbling of power and control cables. Metere display show all the basic electrical parameters (V, A,KW,KVA,P.F, KWH / KVAH ).Model No. PE5120 384 Supply , Installation & Commissioning ofGateway RS485 to Ethernet Converter( Ethernet converter make : Elmeasure) MODEL NO :- GW1500 L 385 Supply , Installation & Commissioning of Software for pre / post metering with facilities:-1. Option configure meter for sanctioned load, terrif, happy hours day2. Option to recharge meter/ bill payment generation.3. Online portals for flat owners to check meter detail & online payment4. Report generation.Mobile app for administrators as well as individuals (Price of this item is excluded in energy meter price) (Make :- Elmeasure) 386 Energy meter sensing Cable :-Supply , Installation & Commissiong 2 Core 0.5 Sq.RS 485, tinted copper communication cablein conduit (meter to meter loop and connected to gateway) 387 DG sensing cable:-Supply , Installation & Commissiong 2 core 1.5mm flexible power cable for DG sensing 388 Supply , Installation & Commissiong of 9 Port Unmanaged switches as per the requirement. 389 SITC of Payment gateway for online recharge facility.(MYgate or NoBrokerHood)including SMS gateway for one year for alerts,(SMS alert if DG sensing is not done in any energy meters). 390 Supply, installation, testing & commissioning of Computer System with Configuration: System Processor - HP ML10, XEON E3 or Higher Version, Operating- System - Windows 10, RAM- 16GB or More, HDD 1 TB, Monitor 17 inch, Keyboard and Mouse. Standard warranty 3 yrs. direct from HP or equivalentThe software should be inclusive of the following:- 1) Connectivity to all meter to the PC.2) Monitoring the Grid & Supply Enery based on real time data.3) Generate the Electricity Bill for Clients.4) Pre paid system with Meter charging app to charge the meter through Paytm, Internet banking, Gpay, Phonepay, Bhim etc as per current payment scenario. Also it shall be capable to show the real time data i.e balance amount, daily basis consumption etc on user / client mobile / any other devices.5) Automatically Maintenance charges deduction. 6) Check & Balance of total energy and energy losses.7) Automatic Alert / Massage to Client / Users for Low Balance. 391 Supply , Installation & Commissiong of Cat 6 cable supply for for network end to end connectivity between meter board and server room 392 Supply , Installation & Commissiong of Cat 6 patch cord for network connectivity between DLC & MC. 393 SUB HEAD-V-STREET LIGHTING ELECTRICAL WORKS 394 Supply,unloading at site of following Outdoor type feeder pillar double door lockable type with epoxy paint. This panel shall be mounting on MS/brick pedestal support upto 400mm high from ground level,cubical, dust, vermin proof and outdoor type (IP65) fabricated as per specification laid in document with following incomming and outgoing feeders including making connections/inter-connections testing and earthing etc. required. 395 Feeder Pillar-01(Outdoor Type - IP 65)Ics=25 KA (FOR EXTERNAL LIGHTING) 396 Incomer:- 397 1 No. Incomer 63Amps 4P, MCCBwith microprocessor based O/C, S/C protections having 3 Nos. phase indicating lamps to show the incoming power control with MCB & 1 no. digital voltmeter with separate selector switch, 1 no. ON/OFF indication 398 63A TP,Cont with ON/ OFF indication lamp,ON/ OFF /TRIP,A/M Switch,Start/Stop push button and along with synchronizing 24 hours timer in auto mode. 399 Bus Bar : 400 A set of TPN, Cu. bus bar rated 150 Amps (after considering necessary deratings of minimum 0.80) for phases and neutral for half capacity of phases. 401 The outgoing feeders as follow: 402 4 Nos.16A 4P outgoing feeder each having 1 no. 16A 4P MCB 403 4 Nos.16A DP outgoing feeder each having 1 no. 16A DP MCB 404 3 Nos. 32 DP outgoing feeder each having 1 no. 32A DP MCB. (connected Before Timer and contector) 405 2Nos.16A 4P outgoing feeder each having 1 no.16A DP MCB(Spare) 406 1 set of complete wiring 407 External Lighting Panel as described above and shown in SLD 408 CABLE SUPPLY, LAYING & TERMINATION 409 Supply & laying of PVC insulated PVC sheathed armoured / unarmored aluminium/copper conductor cable directly in ground.The laying involves digging, making sand cushion cover on top and bottom of cable, providing brick support and filling with excavated earth for following sizes. 410 4c x 16 sqmm Al. Arm xlpe cable 411 3c x 4 sqmm cu. Arm xlpe cable 412 3c x 2.5 sqmm cu. Arm xlpe cable 413 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 414 4c x 16sqmm Al. Arm xlpe cable 415 3c x 4 sqmm cu. Arm xlpe cable 416 3c x 2.5 sqmm cu. Arm xlpe cable 417 POLES 418 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 419 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. 420 CAT- AAA 421 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. 422 SUBHEAD-VI-LIGHTNING CONDUCTOR 423 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 424 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 425 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 426 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 427 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 428 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 429 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 430 SUB HEAD VII- EARTHING 431 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 432 Supply and burying of 600mm x 600mm x 6mm G.I.plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc.as per directions of Engineer-in-charge complete in all respect. 433 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipeand copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc.complete in all respect. 434 Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. 435 Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. 436 Supply and fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. 437 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. 438 Providing and fixing earth bus of 50 mm X 5 mm G.I strip on surface for connections etc. as required. 439 SUBHEAD-VIII-MV CABLE SUPPLY, LAYING AND TERMINATION 440 Supply of the following 1100 volts grade, Aluminium/Copper conductor, XLPE insulated, PVC sheathed, steel armoured/Unarmoured cables as per IS 7098 Part-1and as per technical specifications of this tender and directions of Engineer-in-Charge. 441 4 CORES AL. CONDUCTOR 442 16 sq.mm. Al Ar. XLPE cable 443 25 sq.mm. Al Ar. XLPE cable 444 3.5 CORES AL. CONDUCTOR 445 35 sq.mm. Al Ar. XLPE cable 446 50 sq.mm. Al Ar. XLPE cable 447 70 sq.mm. Al Ar. XLPE cable 448 95 sq.mm. Al Ar. XLPE cable 449 185 sq.mm. Al Ar. XLPE cable 450 300 sq.mm. Al Ar. XLPE cable 451 4 CORES Cu. CONDUCTOR 452 10 sq.mm. Cu. PVC Ar. cable 453 Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. 454 MV CABLE JOINTING & END TERMINATION 455 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(Y-34) 456 3½ X 35 sq. mm (32mm) 457 3½ X 50 sq. mm (35mm) 458 3½ X 70 sq. mm (38mm) 459 3½ X 95 sq. mm (45mm) 460 3½ X 185 sq. mm (57mm) 461 3½ X 300 sq. mm (70mm) 462 4 X 16 sq. mm (28mm) 463 4 X 25 sq. mm (28mm) 464 Supplying and making end termination with brass compression gland andCu lugs for following size of PVC insulated and PVC sheathed / XLPEcu conductor cable of 1.1 KV grade as required. 465 10 sq.mm. Cu. PVC Ar. cable 466 Supply, Unloading, shifting, Storing, Laying, Fixing, Testing, Commissioning & Single compression heavy duty glandsoffollowing sizes of Control Cables, Solid Copper conductor single stranded conductor, XLPE Insulated, cores laid up, PVC tape / Extruded Inner sheathed ,Glavanised round wire Armour, extruded PVC Type, 650V grade on existing cable trays/ in existing hume pipes/ PVC pipes/ GI pipes/ on surface of slabs, walls or masonary/ RCC trenches/ ducts including cables ties, GI saddles, clamps and necessary hard ware. 467 6 core x 2.5 sq. mm cable 468 10 core x 2.5 sq. mm cable 469 24 core x 2.5 sq. mm cable 470 SUBHEAD-IX-CABLE TRAYS 471 Hot Dipped Galvanized Iron Cable Tray 472 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 473 150 mm width X 50 mm depth X 1.6 mm thickness 474 300 mm width X 50 mm depth X 1.6 mm thickness 475 450 mm width X 50 mm depth X 2.0 mm thickness 476 600 mm width X 50 mm depth X 2.0 mm thickness 477 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 478 150 mm width X 50 mm depth X 1.6 mm thickness 479 300 mm width X 50 mm depth X 1.6 mm thickness 480 450 mm width X 50 mm depth X 2.0 mm thickness 481 600 mm width X 50 mm depth X 2.0 mm thickness 482 Supplying and installing following size of perforated hot dipped galvanised iron cable tray tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 483 150 mm width X 50 mm depth X 1.6 mm thickness 484 300 mm width X 50 mm depth X 1.6 mm thickness 485 450 mm width X 50 mm depth X 2.0 mm thickness 486 600 mm width X 50 mm depth X 2.0 mm thickness 487 SUB-HEAD X-GAS Suppression System for Panels 488 SITC of DLP Direct Low Pressure with UL-Listed Lightweight Non-Corrosive Aluminium Cylinder with High grade Stainless Steel 304 Valve Body, Highgrade Brass Isolation Ball Valve 40 bar, High stainless steel Cylinder Mounting Bracket, UL Listed Pressure switch with factory-set for operation, double-throw configuration provides versatile control. The switch is equipped with an O-ring connection for secure, leak-free operation.,High Grade Stainless Steel 304 End of Line (EOL) adaptor with slip-on straight union and Pressure gauge, Stainless Steel 304 Schrader Adaptor with (removable) Pressure Gauge (to indicate pressure of the cylinder) Stainless steelsyphon Tube. Valve filled with CLEAN AGENT 3M NOVEC 1230/AFX-FK-1230 Gas and All components must have ATEX,UL,UKAP,LPCB and IAF approvals.Bidder or supplier must have to submit the OEMsAuthorisation letter and product approvals at the time of bid submission for the warrenty and product assurence. Approved make list- Regulas, AFX-(T), Janus. 489 DLP 4 KG System filled with 3M Novec-1230/AFX-FK-1230 (UL approved) Clean Agent Gas. 490 DLP 2 KG System filled with 3M Novec-1230/AFX-FK-1230 (UL approved) Clean Agent Gas. 491 DLP 1 KG System withfilled with 3M Novec-1230/AFX-FK-1230 (UL approved) Clean Agent Gas. 492 SITC offire detection tube The tube shall be UL Listed, made of modified polyamide, has an internal diameter of 4mm and an external diameter of 6mm. It operates under pressures ranging from 15 to 18 bar, with a minimum burst pressure of 123 bar. The tube is designed with excellent resistance to ozone and UV degradation test certificate to be attached. The bend radius of the tube is 42mm, making it flexible and adaptable to various installation environments. 493 SITC of End of line plug for automatic fire suppression system used for fitting at tube end to terminate the point. Fitting made by brass nickel plated material. 494 SITC of Tee connection 6/6mm Dual Seal Slip-on Swivel Tee High grade Brass Nickle plated material with maxmium pressure 25bar. 495 The stainless steel end-of-line adapter is equipped with a non-return valve and is compatible with 4/6mm tubing. It operates within a pressure range of 13–25 bar, with a maximum pressure of 72 bar, and is designed to withstand temperatures from -20°C to +120°C. 496 SITC of Master Control Unit 2 Zone with audio visual alarm control panel, 2 NO/NC potential free relay contacts discharhe LED indicator, Battery LED indicator system stuts indicator and AC power On LED indicator. 497 SUB HEAD - I - (WET RISERSYSTEM - PUMPING EQUIPMENTS) 498 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : 499 Horizontal type, multistage, centrifugal, split casing pump of cast iron body & steel Stainless impeller with stainless steel shaft, mechanical seal complete. 500 Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. 501 M.S. fabricated Common base plate, coupling, coupling guard, pressure switch , pressure gauge , vibration eliminator pads , foundation bolts etc. as required. 502 Suitable cement concrete foundation duly plastered with anti vibration pads. 503 2280 lpm at 70 m Head 504 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) 505 Horizontal type, multistage, centrifugal, split casing pump of cast iron body & steel Stainless impeller with stainless steel shaft, mechanical seal complete. 506 Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 15 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. 507 M.S. fabricated Common base plate, coupling, coupling guard, pressure switch , pressure gauge , vibration eliminator pads , foundation bolts etc. as required. 508 Suitable cement concrete foundation duly plastered and with anti vibration pads. 509 2280 lpm at 70 m Head 510 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) 511 Horizontal type, multistage, centrifugal, split casing pump of cast iron body & steel Stainless impeller with stainless steel shaft, mechanical seal complete. 512 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325. 513 M.S. fabricated Common base plate, coupling, coupling guard, pressure switch , pressure gauge , vibration eliminator pads , foundation bolts etc. as required. 514 Suitable cement concrete foundation duly plastered and with anti vibration pads. 515 180 lpm at 70 m Head 516 Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shadeas required. . 517 Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 518 80 mm dia 519 150 mm dia 520 250 mm dia 521 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 522 250 mm dia 523 200 mm dia 524 150 mm dia 525 80 mm dia 526 Providing and fixing of Rubber Flexible Coupling with Control Unit PN:16 including Matching flanges & fastner. 527 150 mm dia 528 80 mm dia 529 SUB HEAD - II - (HYDRANTS SYSTEM) 530 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 531 Single headed Stainless steel 532 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 533 Stainless Steel (Grade 304) 534 Supplying & fixing 63 mm dia gun metal short branch pipe with 20mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: 535 Stainless Steel (Grade 304) 536 Providing, installation, testing and commissioningweatherproof lockable cabinet of size not less than0.90 x 0.60 x 0.30 mtr made out of M.S. sheet 2mm thick havingcentral openingand 6 mmthick glazedglass doors (Two nos.)suitably markedon the outside with the letters FIRE HOSE including necessary lockingarrangement and shall be painted with one coat of primer and two coats of synthetic enamel paint of approved shade as required as per specifications. 537 Supplying, installation, testing and commissioning of fire brigade connection of cast iron body with gun metal male & female instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 538 2 way - 100 mm dia M.S. Pipe 539 4 way - 150 mm dia M.S. Pipe 540 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 541 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 542 SUB HEAD - III - (PIPING, VALVES AND ACCESSORIES) 543 MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 544 150 mm dia 545 200 mm dia (wall thickness 6.3 mm) 546 250 mm dia (wall thickness 6.3 mm) 547 Providing, laying, jointing, testing & commissioning of heavy classM.S. pipes conforming to IS: 1239/3589 complete with fittings including trenching ,refilling and wraping coating etc.(external work) including all fittings andaccessories like tees, elbows, flanged joints, rubber insertion, nuts, bolts or cutting and welding joints. Providing thrust block at distance specified as per specifications. (Pipe shall be provided with anti corrosive protective treatment with coal tar/asphalt tape confirming to IS: 10221 standard complete as per specification). All work complete as per specification and as directed by Engineer-In-Charge. (All the fitting i.e. tee /elbow etc. for Valve connections etc. will be flanged joints). 548 150 mm dia 549 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 550 80 mm dia 551 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 552 80 mm dia 553 150 mm dia 554 200 mm dia 555 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronzeworkingpartscomprisingofwatermotor alarm, bronze seat clapper, clapper arm and hydraulically drivenmechanical gong bell to sound continuousalarmwhen thewet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve completewith drainvalveandbypass, test control box, ball valves, MSpipeof requiredsize, flanges,orificeplate,gasket etc of follwing sizes as required : 556 150mm dia 557 SUB HEAD - IV - (FIRE EXTINGUISHERS) 558 Supply, installation, testing and commissioning of ISI marked Fire and wall suspension bracket fire Extinguisher, Trolley mounted carbon-dioxide type capacity 25 Kg. conforming to IS: 2878 Flat base including valve, discharge hose of not less than 10mm dia 1m long complete in all respects including wheeled trolley, carrying handle and initial fill with CO2 gas as per IS: 307-1996 filled to a filling ratio of not more than 0.667. 559 Supply, installation, testing and commissioning in position approved make fire bucket of 24 gauge, galvanized steel, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on bottom dome with letters ‘FIRE’ in black and gold with all mounting bracket and screws. 560 Supply, installation, testing and commissioning of fire Bucket Stand including sheet metal (16 gauge) shade for 5 buckets. Platform and associated civil works complete. 561 SUB HEAD - V - (ELECTRICAL PANEL) 562 Fire Fighting Main Panel 563 Incoming 564 800A, 50kA 4 Pole MCCB, Ics=100% Icu rating 565 Digital Voltmeter 0-500V with selector switch 566 Digital Ammeter (0-800 A) with selector swtich & CTs etc. 567 LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps 568 Set of Copper Bus Bar 300A 569 OUTGOING 570 ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) 571 Main Fire Pump 572 250 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2sets 573 Jockey Pump 574 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2sets 575 DIESEL ENGINE CONTROL 576 Control for diesel engine comprising - 577 Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode 578 Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication 579 Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter 580 All standard relays and accessories for automatic operation of diesel engine 581 System Controller 582 Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification. Fire panel as above
Contract Date: Aug 21, 2025 Contract Value : 4.69 Crore
Government Departments No of Bidders 2
Uttar Pradesh View Result →
TenderDetail
Loading tenders