View Bid Results For Non Conventional Wtp Tenders

We found 4 Bid Results related to non conventional wtp tenders. You can find Contractor details who won non conventional wtp tenders along with contract details in Bid awards announcements section.

Filters
Stage
2
2
Tender Publishing Platform
4
State / UT
3
2
1
1
Contract Value
2
1
1
Publish Date
0
0
0
0
0
Sector
3
2
1
1
Ownership
2
3
1
Within keyword
Active filters:
Showing 1–1 of 4 tenders matching your filters
1.
Drinking Water Supply and Sanitation #9460337 Technical Bid
tender for Baruasagarnagar Palikaparishad Reorganization Water Supply Scheme Under Amrut 2.0 Survey Soil Investigation Design Supply Of All Materials Labour Tandp Etc Required For Construction Erection Completion Testing And Commissioning Of Water Supply Works Such As Wtp Rcc Oht Zps Cwr Cum Pumping Station Rising Main Feeder Main, BARUASAGAR NAGAR PALIKA PARISHAD REORGANIZATION WATER SUPPLY SCHEME UNDER- AMRUT 2.0, DISTT. JHANSI Sl. No. Item Description 1 CIVIL WORK 2 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for Design and Drawing, Supply of all materials, labour, T&P etc. required for construction,of specified capacity (3.6MLD) of WTP based on 20 Hrs. operation (3.6MLD + 25%) extra over loading capacity includinginlet chamber, aeration fountain / cascade, inlet channels including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and flow measuring arrangement, clariflocculator with conventional, filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby, sludge handling unit and recycling of collected water from sludge etc. complete,All WTP scada Opratedexternal and internal electrification, laboratory building with all specified lab equipment, admin building, Quarter (One no.), sanitary block with necessary water supply and drainage arrangement, campus roads, landscaping and other campus development works, rain water harvesting, etc. all required works complete as per the direction of Engineer-in-Charge.The WTP shall be fully automatic based on PLC/SCADA with real time remote monitoring system and online contineuous effluent monitoring system. 3 For water works compound Construction of Bituminious approach road including preparation of subgrade. 4 Earth filling inside the water works campus. 5 Cutting of bushes, removing garbage form w/w site and dewatering of sub soil water at wtp & including maintinance of existingintake well Painting of intake well and existing water works campus 6 CONSTRUCTION OF SUMP-CUM-CLEAR WATER RESERVOIR-CUM-PUMP HOUSE OF 250 KL CAPACITY AT ZONE-3WATER WORKS CAMPUS (CWR) 7 RCC CWR;Detailed Survey, Design and Drawing, supply of all material, labour, T&P etc. required for construction of250 KL Ractangular, R.C.C Clear Water Reservoir cum pump house including various works like 1 m wide stair case with stainless steel hand railing to go inside reservoir, sump below the pump house area, stainless steel railing over the R.C.C slab of reservoir, Granular texture finish on exterior surface of pump house, gantry beam, food grade epoxy coating of FOSROC / Ciba-Geigy or reputated brand on inside surface area of water container after testing for water tightness, kota ston floring,bypass arangment ,and soil testing for Bearing capacity of capacity mentioned as under:Note : The bid prices of Clear Water Reservoir / Pumping Stations are to be submitted considering the depth of excavation may extend up to 6 m BGL. Design and Drawing approved by competent authority and Design vetted by Reputed Govt. Engineering College.(250 KL capecity) 8 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for , Design,Drawing includingSupply of all materials, labour, T&P etc. required for construction, Construction ofLT Panel Room (RCC Frame Structure) as per type design (5m x 5m x 4 m) 9 Survey, Soil investigation,(including topographical survey, geotechnical investigation and other Surveys as required) for , Design,Drawing includingSupply of all materials, labour, T&P etc. required for construction, Construction ofMeterRoom (RCC Frame Structure) as per type design (4m x 4m x 4 m) 10 Estimate of RCC OverHead Tank of 450 KL. Capacity / 22 M. Staging FOR ZONE -3 Barua Sagar 11 450 KL 22 M Staging Survey Design , drawing and Supply of all materials, labour and T&P etc. complete for the construction of OHT of 450 KL. capacity and staging 22 M with 1.00 m. wide P.C.C. appron all around with 15 cm. Semi circular P.C.C. drain, 1 m. wide RCC stair case from ground level upto balcony, M.S. Ladder with hand rails on both sides from balcony to top dome and inside the tank, 1 m wide RCC balcony alround the tank wall with proper railings of 20 mm. dia. medium quality G.I. pipes in 3 rows on both sides of staircase, balcony and at the top of domes and at each landing supported on RCC posts spaced at not more than 1.50 m. intervals, proper ventilators at top, electronic water level indicator with invertor, Lightening conductor as per latest I.S. code or electricity rules, 600 mm. dia. medium pattern C.I. Manhole cover hinged with locking arrangement, fixing and jointing vertical DID/F pipes, specials and duck foot bends of required size for Inlet, outlet, fixing of outlet sluice valve and washout sluice valves with all jointing materials for proper completion and other appurtenant works, including excavation in all type of soils, painting on exposed surface with one coat of primer and two coats of approved weather coat paint, painting of vertical pipes and railings with approved anticorrosive paints and also including testing of the Overhead Tank, including following items : Supply of following sizes of DID/F pipes conforming to IS 8329 / 2000 or its latest amendment upto rail head including all taxes, duties, insurance etc. Inlet pipe 250 mm. dia.,Outlet pipe 300 mm. dia.,Overflow pipe 300 mm. dia.Washout pipe 100 mm. dia.Carting of above size DI K-9 of pipes upto site of works and lowering them into the trenches and laying true to alignment and gradient and jointing of pipes complete ( including testing of pipelines and cutting of pipes for making up the length excluding the cost of trenches. ) Inlet pipe 350 mm. dia. Outlet pipe 400 mm. dia. Overflow pipe 300 mm. dia. Washout pipe 100 mm. dia . Supply of following diameter ISI Mark Sluice Valve conforming to IS 780/ 1984 or its latest amendment of standard make ( Kirloskar or IVC make ) including all taxes etc. and carting, loading and uploading upto departmental store and carting of following fittings / specials to the site of work, lowering them into the trenches, fixing in position and jointing them with pipe lines, fixing in position and jointing them with pipelines and testing etc. complete including supply of all jointing materials. 400 mm. dia. ( In outlet pipe )100 mm. dia. ( In washout pipe ) Supply of all materials, labours, T&P etc. all complete to construct sluice valve chamber of following sizes.For Outlet Pipe For Washout Pipe Provision for the disposal of overflow water, washout water from chambers to nearest suitable point of disposal including supply of pipes, its laying, jointing, excavation and protection works at the point of disposal. including Provision for soil testing. 12 DISTRIBUTION SYSTEM OF BARUASAGAR ZONE-1,2 and 3 and CLEAR WATERGRAVITY MAIN FROM WTP TO ZONAL WATER WORKS AND RISING MAIN FORZONES-03 (Chui Khadan) BARUASAGAR NAGAR PALIKA PARISHAD 13 Excavation for pipe line trenches in soil mix / all type of rocks with moorum/shingles/kanker requiring use of special T&P ie. pick axe, sabbals etc. lift upto 1.50 m lead upto 50 m. stacking and spreading as directed, normal dewatering,preparing the bed,Filling watering ramming of excavated earth into pipe line trenches and disposal of surplus earth upto a distance of 10 KM from the centre of the pipe line trenches 14 0.00 To 1.5 m Depth 15 Same as above but excavation in all type of rock 16 0.00 To 1.5 m Depth 17 Supply of ISI mark DI K-9 and K-7 S&S pipes (push on joints) of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) andand Supply of specialsconforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. with jointing Materials including all taxes, freight, loading, unloading, insurance, duties etc., all complete. and supply of all DI DF/DI DS specialslike Tees, all type bend ( For Distribution, Feedermain And Rising main Purpose ) 18 80 mm Dia DI K-7 19 100 mm diaDI K-7 20 125 mm diaDI K-7 21 150 mm diaDI K-7 22 200 mm dia Distribution system and Junction (B-D) to Cwr at zone -3DI K-7 23 250 mm diaDI K-7 24 200 mm dia DI-K-9 25 Lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete.Carting of following sizes (Dia. in mm.) of pipes and specials including jointing mateirals from store to site of work lowering the same into excavated pipe line trenches true to alignment and gradient and jointing the same including testing of pipe line including supply of all materials labour T&P etc complete and as per direction of Engineer Incharge. 26 80 mm Dia 27 100 mm dia 28 125 mm dia 29 150 mm dia 30 200 mm dia Distribution system and Junction (B-D) to Cwr at zone -3 31 250 mm dia 32 200 mm dia DI-K9 Zone-3 33 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 PN 1.0 34 D.I.Sluice valve 35 100 mm dia 36 150 mm dia 37 200 mm dia 38 250 mm dia 39 Fire Hydrant as per IS Code 908 : 1975 40 65 mm Dia 41 Air valves as per IS 14845 : 2000 PN 1.0 42 50 mm Dia 43 20mm Dia 44 Scour valves 45 50 mm dia 46 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 PN 1.0 47 100 mm dia 48 150 mm dia 49 200 mm dia For Zone -3 50 250 mm dia 51 Fire Hydrant as per IS Code 908 : 1975 52 65 mm Dia 53 Air valves as per IS 14845 : 2000 PN 1.0 54 50 mm Dia 55 20 mm Dia 56 Scour valves 57 50 mm dia 58 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 59 Sluice valve chambers (Masonry type) 60 100 mm to 250 mm dia 61 Scour valve chambers (Masonry type) 62 Fire hydrantschambers 63 Air valve chambers 64 Dismantling (cutting by sharp eage machine tools) and Reinstatment of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials. 65 Bituminious Road 66 Cement Concrete Road (CC) 67 Interlocking Tiles Road 68 Construction of thurst block in RCC 1:2:4 at bends & Tee in feeder main including supply of all labour, material, T&P etc. complete as per the details given below :- 69 Mild steel or iron work in R.C.C. wrought to required shape as necessary including bending for proper completion of the work including supply of steel and wastage etc. 70 Provision for crossing of Nalas (0.5mto 2.0 m innerwidth) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain. 71 0.5 - 1.0 m 72 1.0 - 1.5 m 73 1.5 - 2.0 m 74 Providing new water supply house connection to the consumersfrom new distribution pipe line of following diametersincluding making ferrule connection, cost of ferrule, 15 mm dia HDPE and GI pipe, saddle piece, ball valve, specials, excavation, refilling of pit etc. complete. It also includes supply of all materials, labour, T&P Including Dismentling and Reinstatment etc. required for proper completion of the work. As per attached drawing. 75 In all tupe of soil and rock 76 Bituminious Road 77 For 80 to 100 mm dia 78 For 125 to 150 mm dia 79 For 200 mm dia 80 Cement Concrete Road 81 For 80 to 100 mm dia 82 For 125 to 150 mm dia 83 For 200 mm dia 84 Interlocking Tiles Road 85 For 80 to 100 mm dia 86 For 125 to 150 mm dia 87 For 200 mm dia 88 Kachha Road 89 For 80 to 100 mm dia 90 For 125 to 150 mm dia 91 For 200 mm dia 92 Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 93 Brick masonry in cement mortar 1:4 94 12mm thick plaster in cement mortar 1:4 95 RCC M-20 (including MS work) 96 Stone masonry in cement mortar 1:6 97 Shifting of Existinghouse connection from existing pipe line to new pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 98 Repairing of house connection which is coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 99 Barricating of pipe line trenches by using bamboo poles,sheets, rope with red flags, Glow-caution boards, diversion boards & red lights Complete as per the direction of engineer incharge 100 Interconnection of existing pipe line to new pipe line including fitting special pipe, tee, bend, reducer pipe all complete as per site requirment T&P etc material complete as per the direction of engineer incharge 101 80 mm dia 102 100 mm dia 103 125 mm dia 104 150 mm dia 105 Disposal of surplus earth includingmoorum/stone bolder /building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 106 Boundary wallat zone -3 (chhui khadan) Rcc column based boundary wall as per design 30x50 m BOUNDARY WALL Construction of Boundry wall around campus as per unit estimate with RCC Columns @ 3.0m c/c distance with plinth beam and brick work including supply of all Materials, Labour, Tools and Plants etc. complete., as per departmental type drawing.Construction of2.0 meter high compound wall from formation level of campus,comprising of 230mmx230mm RCC Columns @ 3.0 m c/c distance with 230 mm thick beam at plinth and top, brick work of 230 mm thick in 1:4 and 12 MM THICK 1:4 cement plaster over all surface of wall , two coat of Exterior emulsion paint of approved reputed make over one coat of primer and even surface preparation by applying 2-3 layer of approved reputed make Puttyas perdesign approved by engineer in Charge, including supply of all material, labour, T& P etc complete. 107 3.60 m wide mild steel gate with rcc columns with 1.0 m wicket gate 108 earth filingincludingmoorum/stone bolder /building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. 109 Provide all materials, labour and T&P to construct single roomed staff quarter as per type design and quantities of unit estimate all complete , including common stair case and other miscellaneous works. The plinth area of each staff quarter is 57.706 sqm.Detailed Survey, Design& Drawing, Construction of Residential Building based Office Building on R.C.C frame structure at different location finished with all respect, flooring made up with vitrified Tile/ Kota stone , Flush door shutter , glazed window cum ventilation including mosquito proof shutter, waterproofing at roof , anti-skid tile at toilet / bathroom / kitchen , water supply and sanitary work & electrification with all fixture, painting with 3 coat apex at exterior surface and emulsion at interiorsurface including2 coat Birla white puttyofbuilding, apron around building, appropriate size of septic tank and soak pit, including supply of all material, labour, T&P complete as per the direction of the engineer in charge 110 Plinth area of building 57.706 Sqm 111 Re-instatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movemen 112 Bitumen roadTYPE AConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-GSB G-1 (One coat) (90-40 mm) = 12.5 cmG -2 (one coat) (45-63 mm) = 7.5 cmG - 3 (one coat) (22.5 - 53 mm) = 7.5 cmBM (One coat)= 7.5 cmSDBC (One coat)= 2.5 cm 113 TYPE BConstruction of bitumen road as per UPPWD specification including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-Bitumen Road (SDBC + Tack coat)SDBC (One coat)= 2.5 cmTack coat with bituminous emulsion (MS)= 0.25 kg/sqm(30% consider for over dismantling of existing road) 114 Cement Concrete Road(100mm Thick PCC 1:4:8 and 100mm Thick CC 1:2:4) 115 C.C. Interlocking Tiles Road Type AConstruction of 80 mm tihck C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)Sand= 50 mm thick local sand lair for preparation of surfaceTiles = 30% new + 70% old 116 E and M Work 117 PUMPING PLANT AND ACCESSORIES FOR EXISTING INTAKE WELL ( ZONE-1) KHANDI (2.5 MLD) 118 Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.14mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 119 2050LPM, 25.00 HP, 37m Head 120 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm bend, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 121 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 122 Valve actuator of size 150mm for pumps and common header 123 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 124 150 mm Dia 125 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 126 Electromagnetic flow meter of size 150mm for common header 127 ELECTRICAL ITEMS:- 128 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 129 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 130 CE/UL Certified level transmitter for Intake well :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 131 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 132 CE/UL Certified Pressure transmitter for pumps 133 CE/UL Certified Pressure transmitter forCommon Header 134 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 135 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 136 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 137 Cable trench Chequerred plate 138 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 139 Internal & External electrification of pumping station. 140 PUMPING PLANT AND ACCESSORIES FOR EXISTING INTAKE WELL ( ZONE-2)FOR (3.20 MLD+3.50 MLD) 141 Supply of Vertical type self-oil lubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.14mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 142 2500LPM, 30.00 HP, 37m Head 143 MAIN PIPING AND VALVES :-Supply of 200mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 250mm common Header upto 1 m. outsidethe pump house along with 250 x 200 x 250 mm A/F Tee,250 mm bend, 250 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 144 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 145 Valve actuator of size 200mm for pumps 146 Valve actuator of size 250mm for common header 147 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 148 200 mm Dia for pumps 149 250 mm Dia for common header 150 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 151 Electromagnetic flow meter of size 250mm for common header 152 ELECTRICAL ITEMS:- 153 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 154 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION250A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 155 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 156 CE/UL Certified Pressure transmitter forpumps 157 CE/UL Certified Pressure transmitter forCommon Header 158 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 159 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 160 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 161 RENNOVATION OF EXISTING 160 KVA SUB STATION AT INTAKEWELL 162 Supplying of indoor type floor mounted metal clad, 11 KV VCB panel with 1No. VCBs, totally enclosed & fully interlocked, horizontal drawout, horizontal/ vertical isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and auto/manually closing breaker suitable for use on 11 KV, 3 Phase, 50 Hz A.C. supply with short circuit fault level of 100 KVa, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 1600Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 4 NO+4NC and equipped with following switchgears and accessories i/c connections suitable for 11 KV cable (cable entry from *bottom/ top/side) end termination with heat shrinkable jointing material etc. as required. (Note- Cost of end termination not included in this item)(a) Incoming – ½* No 800Amp. VCB(b) 1* No. – 11 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burder with 1 No. Voltmeter (0-15KV), analog/digital* type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 12 KV on incomer.(c) 1* No. – (0-100 A) dual scale Ammeter, analog/digital* type, selector switches for ammeters.(d) 1* No. – Microprocessor based numerical relay with O/L, E/F and S/C protection.(e)1* No. – Set of dual core dual ratio 3 CTs 300/150/5/5 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection.(a) Outgoing – 2Nos. 800Amp. VCB(b) 2Nos. – (0-100 A) Ammeters, dual scale analog/digital* type & selector switches for Ammeters.(c) 2 Nos. – Microprocessor based numerical relays with O/L, E/F & S/C protections.(d) 2 Nos. – Setofdualcoredualratio3CTs 100/ 50/5/5 A of 15 VA burden and accuracy Class-1.0 for metering and class 5P10 for protection.1. Supply of power pack 24 volts complete with battery and charging device. 163 Supply of 50 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel and panel to transformer. 164 Supplying of 160KVA, 11/0.415 KV, 3 Phase, 50 Hz, Dyn 11, indoor ONAN type, copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.5% & -7.5%, having cable end boxes on HV side suitable for 3x150sqmm XLPE cable of 33 KV grade and bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 1180 & as per specification attached complete in all respects as required at site. 165 Supplying of cubicall type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2 mm thick for framework and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630Amp capacity extensible type TPN aluminium alloy bus bars of hight conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth barof size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from mainbus bar to switch gears with required size of Al. bus bars and control wiring with 50sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :-(I) Incoming : 2 Nos.. 630 Amps horizontal drawout type air circui+B12t breaker of fault breaking capacity 50 KA (Ics=Icu upto433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/ OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each ACB.(a) Independent manual spring closing mechanism- 1 No.B10(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Analog 96 mm square flush pattern /Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/ MCBs-1 set.(d) Analog 96 mm. square flush pattern/ Digital* type Ammeter (0-630Amp), with selector switch and one set of 3 nos. CT’s of ratio10/5A Class I accuracy and 15 VA burden- 1set. (e) 3 Nos. Phase indication LED lamps with2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C.(II) Bus Couplers :1Nos. 630Amps drawout type, air circuit breakers offault breaking capacity 50 KA (Ics=Icu upto433 V) manually operated, with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact conforming to IS 13947- 2 : 1993 as amended upto date complete with following accessories for each ACB:(a) Independent manual spring closing mechanism- 1 No.(b) Breaker ‘ON’ indicating light with back up 2 A HRC fuse test terminal block, fuses, circuits contactors for positive electrical interlocking of breakers, etc. as required- 1 set.(III) Bus Bars :TPN aluminium bus bars of minimum of 630Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. 166 (IV) Interlocking :Electrical through advance contacts in ACB’s (incomers & bus couplers) and mech- anical (castel key) interlocking should beprovided to ensure that only one supply is available at a time on each section of bus and to eliminate any possiblility of accidentally approaching two supplies at one bus section.(V) Outgoing :(a) 1Nos. 630Amp 4 Pole ACB (Ics = kA upto 433 V)/SFU with HRC fuse (BC : 80 kA)(b) CT’s of ratio 10/5Amps 4Nos.4Set (1 set of 2 Nos.)(c) Analog 96 mmsq/Digital* type ammeter (0-100Amp) with selector switch set. 167 Supply and laying of 650/1100 volt grade 185 sq mm 3½ core PVC Armoured Aluminium cable from transformer to L.Tpanel and from outgoing panel to distribution panel (1x3½x185 sq mm) 168 Making Earth pit for earthing complete in all respect. Earthing system shall executed as per IS:3043 and I.E. rules. 169 Installation and commissioning of 11 KV/0.4 KV substations including HT Panels and L.T. main control panel including all labor T&P complete in all respect. 170 Supply and making of indoor cable end termination joint kit of size 70 sq mm 3 core for 11 KV H.T. XLPE cable 171 Supply and making of outdoor cable end termination joint kit of size 240 sq mm 3 core for 11 KV H.T. XLPE cable 172 Provision for routine testing of equipments such as transformer, HT Panels and main LT Panel at manufacturer’s works. 173 NOC from Electrical safety department for all field installations such as pumping plants, substation etc.( 11KV Power connection is already available at site. 174 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT WTP ( EXISTING 125KL/20 M ) 175 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 176 1845 LPM, 25.00 HP, 32m Head 177 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 178 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 179 Valve actuator of size 150mm for pumps 180 Valve actuator of size 150mm for common header 181 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 182 150 mm Dia for pumps 183 150 mm Dia for common header 184 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 185 Electromagnetic flow meter of size 150mm for common header 186 Electromagnetic flow meter of size 250mm at CWR Inlet 187 ELECTRICAL ITEMS:- 188 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 189 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 3 No, SpreaderLinks &Extended ROH for MCCB- 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 190 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 191 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 192 CE/UL Certified Pressure transmitter for pumps 193 CE/UL Certified Pressure transmitter forCommon Header. 194 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 195 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 196 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 197 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 198 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 199 Internal & External electrification of CWR 200 PUMPING PLANT AND ACCESSORIES FROM CWR TO CWR HILLOCK ( EXISTING 850 KL) 201 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 202 1845 LPM, 20.00 HP, 22m Head 203 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 300mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 150 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 204 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 205 Valve actuator of size 150mm for pumps 206 Valve actuator of size 150mm for common header 207 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 208 150 mm Dia for pumps 209 150 mm Dia for common header 210 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 211 Electromagnetic flow meter of size 150mm for common header 212 Electromagnetic flow meter of size 250mm at CWR Inlet 213 ELECTRICAL ITEMS:- 214 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 215 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION63 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 216 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 217 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 218 CE/UL Certified Pressure transmitter for pumps 219 CE/UL Certified Pressure transmitter forCommon Header. 220 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 221 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 222 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 223 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 224 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 225 Internal & External electrification of CWR 226 PUMPING PLANT AND ACCESSORIES FROM CWR WTP TO OHT 350 KL / 22 M 227 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 228 1680LPM, 30.00 HP, 44m Head 229 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outsidethe pump house along with 150 x 200 x 150 mm A/F Tee,200 mm duckfoot bend, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 230 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 231 Valve actuator of size 150mm for pumps 232 Valve actuator of size 200mm for common header 233 Valve actuator of size 300mm at OHT Outlet 234 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 235 150 mm Dia for pumps 236 200 mm Dia for common header 237 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 238 Electromagnetic flow meter of size 200mm for common header 239 Electromagnetic flow meter of size 300mm at CWR Inlet 240 Electromagnetic flow meter of size 300mm at OHT Outlet 241 ELECTRICAL ITEMS:- 242 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 243 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION250A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 244 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 245 CE/UL Certified level transmitter for CWR 246 CE/UL Certified level transmitter for OHT 247 CE/UL Certified Pressure transmitter :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 248 CE/UL Certified Pressure transmitter for pumps 249 CE/UL Certified Pressure transmitter forCommon Header, OHT outlet etc. 250 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 251 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 252 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 253 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 254 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 255 Internal & External electrification of Pump house 256 PUMPING PLANT AND ACCESSORIES FROM CWR WTP TO EXISTING OHT 1100 KL / 17 M 257 Supply ofEnergy Efficient Totally Enclosed Fan Cooled (TEFC) Squirrel Cage Induction Motor (IE2) ( Enclosure conforming to protection IP55) Horizontal Foot Mounted Induction Motor, continuously rated suitable for operation on 415+/-10% ,50Hz+/-5% , A.C. supply with class F insulation for 50 Deg. C ambient temperature and altitude less than 1000 M above MSL and conforming to IEC:60034-1 & IS 12615:2018. with pump with following specifications. 258 1680LPM, 25.00 HP, 34m Head 259 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side, bye pass arrangement and 100mm common Header upto 1 m. outsidethe pump house along with 150 x 200 x 150 mm A/F Tee,200 mm duckfoot bend, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions. 260 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 261 Valve actuator of size 150mm for pumps 262 Valve actuator of size 200mm for common header 263 Valve actuator of size 400mm at OHT Outlet 264 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 265 150 mm Dia for pumps 266 200 mm Dia for common header 267 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 268 Electromagnetic flow meter of size 200mm for common header 269 Electromagnetic flow meter of size 300mm at CWR Inlet 270 Electromagnetic flow meter of size 400mm at OHT Outlet 271 ELECTRICAL ITEMS:- 272 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 16 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 273 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION200A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION80 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 274 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 275 CE/UL Certified level transmitter for CWR 276 CE/UL Certified level transmitter for OHT 277 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 278 CE/UL Certified Pressure transmitter for pumps 279 CE/UL Certified Pressure transmitter forCommon Header, OHT outlet etc. 280 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 281 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 282 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 283 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 284 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 285 Internal & External electrification of Pump house 286 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT CHUIKHADAN ( 450KL / 22M ) 287 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 288 1860LPM, 30 HP, 40m Head 289 MAIN PIPING AND VALVES :-Supply of 150mm Main piping & valves complete of suitable size and quantity required for delivery side and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 150 x 150 mm A/F Tee,150 mm duckfoot bend, Enlargers, 200 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 290 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 291 Valve actuator of size 150mm for pumps 292 Valve actuator of size 150mm for common header 293 Valve actuator of size 300mm at OHT outlet 294 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 295 150 mm Dia for pumps 296 150 mm Dia for common header 297 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 298 Electromagnetic flow meter of size 150mm for common header 299 Electromagnetic flow meter of size 300mm at CWR Inlet 300 Electromagnetic flow meter of size 300mm at OHT outlet 301 ELECTRICAL ITEMS:- 302 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 25 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 303 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION125A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION100 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 304 CE/UL Certified level transmitter for CWR :- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 305 CE/UL Certified level transmitter for CWR 306 CE/UL Certified level transmitter for OHT 307 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 308 CE/UL Certified Pressure transmitter for pumps 309 CE/UL Certified Pressure transmitter forCommon Header. 310 CE/UL Certified Pressure transmitter for OHT outlet 311 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 312 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 313 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 314 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 315 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 316 Internal & External electrification of CWR 317 PUMPING PLANT AND ACCESSORIES FROM CWR TO OHT AT KANSHIRAM COLONY (EXISTING) 318 Supply of Vertical type self-waterlubricated statically, dynamically, hydraulically balanced turbine pumpcapable of discharging at thefollowingdutyconditionasgivenbelowduetoallcauseswith surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amendedthereaftertosuitthesitecondition.ThePumpBowlassembly and casing shall be CI IS 210 FG: 260 with suitable coating inside casing of 500 DFT, suitable for protection against corroision,erosion and prevent oxidation.Impeller and Wearing / Neckringshall be Duplex stainless steel CD4MCu (Chromium-24.5% minimum,Carbon < 0.04% ) as per ASTM A890 GrlA or DIN 1.4474-EN 10088, Hardness 220-260 BHN,pump shaft-Stainless steel AISI 410, pumps and line shaft sleeve - stainless steel with ceremic coating 700 BHN,Strainer-SS 304,coupling between pump ang motor - Flexible pin bush type and bearings shall be Anti friction L-10 with 60000 Hrs life at 1450 rpm.06mtr/suitablelengthcolumnassembly, with vertical Solid shaft Squirrel cage induction motor(IS:126152011/IEC60034-1)suitablefortheabovepump continuous rated TEFC IP-55 with Class F insulation for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump. Capacity as follows :- 319 700LPM, 12.5 HP, 35m Head 320 MAIN PIPING AND VALVES :-Supply of 100mm Main piping & valves complete of suitable size and quantity required for delivery side and 100mm common Header upto 1 m. outsidethe pump house along with 100 x 100 x 100 mm A/F Tee,100 mm bend, Enlargers, 100 mm blind flange, D/F Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe,mechanical joints and valve etc. complete in all respect as per site conditions suitable for above pumping plants. 321 Motor operated actuator with sluice valve :- Supply of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 322 Valve actuator of size 100mm for pumps 323 Valve actuator of size 100mm for common header 324 Valve actuator of size 250mm at OHT outlet 325 Non return valve :- Supply of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 326 100 mm Dia for pumps 327 100 mm Dia for common header 328 CE/UL Certified Electromagnetic flow meter :- SupplyofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 329 Electromagnetic flow meter of size 100mm for common header 330 Electromagnetic flow meter of size 250mm at CWR Inlet 331 Electromagnetic flow meter of size 250mm at OHT outlet 332 ELECTRICAL ITEMS:- 333 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 10 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 334 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION100A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION40 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 335 CE/UL Certified level transmitter:- SupplyofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 336 CE/UL Certified level transmitter for CWR 337 CE/UL Certified level transmitter for OHT 338 CE/UL Certified Pressure transmitter:- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 339 CE/UL Certified Pressure transmitter for pumps 340 CE/UL Certified Pressure transmitter forCommon Header. 341 CE/UL Certified Pressure transmitter for OHT outlet 342 Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.(Competible to SCADA) 343 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 344 Installation of all equipments, power wiring of Electrical equipments and commissioning of the pumping plants 345 RubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 346 Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 347 Internal & External electrification of CWR 348 INTERNAL AND EXTERNAL ELECTRIFICATION FOR WTP 349 Internal and External Electrification 350 Outdoor Lighting 351 Supply installation tesling & Commissioning of IS0 certiftedcompany made high mast lighting system (as per PLG 07 of ILP UK technical report no 7 of ILE UK /IS:875 Part-1 - 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal (Octogonal) section, telescopic jointed and welding as per BS 5135 and also provide test certificate for wind tunnel test for High mast fixtures. complete in all respect. 352 12.5 Mtr. HM (in 2 Section) 353 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 Im/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz‡3%, Power Factor >0.95 ,driver Efficiency >85% .THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K + 1355K, Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screenprinting on die cast housing to allow traceability/authenticity. Fixture-shall be IS 10322 Complianced and also provide test Certificate/ report with liable warranty of product/accessories. 354 High Power LED Flood Light 200W 355 Indoor Lighting 356 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with2.5 KV internal/external surge protection B|S certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt ,THD < 10 % , p.f.>0.95,CRI >80 . life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000°K / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing and also provide test certificate of LED Fixtures from NABL. 357 36 W LED light Fixture 2 x 2 with acrylic / prismatic front cover. 358 Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 359 Automation For Intake Well 360 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 361 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 362 CE/UL Certified Intelligent energy meters 363 CE/UL Certified Surge protector for control panel 364 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 365 Cable 366 (i) Complete cabling above 3 Pumps 367 Security Survelliance IP Camera with recorder (optional) 368 Installation, commissioning & testing 369 AUTOMATION FOR CWR-1A 370 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 371 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 372 CE/UL Certified Intelligent energy meters 373 CE/UL Certified Surge protector for control panel 374 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 375 Turbidity Analyzer at CWR 376 PH Analyzer 377 Chlorine Analyzer 378 Cable 379 (i) Complete cabling upto 3 Pumps 380 Security Survelliance IP Camera with recorder (optional) 381 Installation, commissioning & testing 382 AUTOMATION FOR CWR-1B 383 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 384 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 385 CE/UL Certified Intelligent energy meters 386 CE/UL Certified Surge protector for control panel 387 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 388 Turbidity Analyzer at CWR 389 PH Analyzer 390 Chlorine Analyzer 391 Cable 392 (i) Complete cabling upto 3 Pumps 393 Security Survelliance IP Camera with recorder (optional) 394 Installation, commissioning & testing 395 AUTOMATION FOR CWR-2A 396 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 397 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 398 CE/UL Certified Intelligent energy meters 399 CE/UL Certified Surge protector for control panel 400 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 401 Turbidity Analyzer at CWR 402 PH Analyzer 403 Chlorine Analyzer 404 Cable 405 (i) Complete cabling upto 3 Pumps 406 Security Survelliance IP Camera with recorder (optional) 407 Installation, commissioning & testing 408 AUTOMATION FOR CWR-2B 409 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 410 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 411 CE/UL Certified Intelligent energy meters 412 CE/UL Certified Surge protector for control panel 413 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 414 Turbidity Analyzer at CWR 415 PH Analyzer 416 Chlorine Analyzer 417 Cable 418 (i) Complete cabling upto 3 Pumps 419 Security Survelliance IP Camera with recorder (optional) 420 Installation, commissioning & testing 421 AUTOMATION FOR CWR-2C 422 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 423 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 424 CE/UL Certified Intelligent energy meters 425 CE/UL Certified Surge protector for control panel 426 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 427 Turbidity Analyzer at CWR 428 PH Analyzer 429 Chlorine Analyzer 430 Cable 431 (i) Complete cabling upto 3 Pumps 432 Security Survelliance IP Camera with recorder (optional) 433 Installation, commissioning & testing 434 AUTOMATION FOR CWR-2D 435 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 436 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 437 CE/UL Certified Intelligent energy meters 438 CE/UL Certified Surge protector for control panel 439 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 440 Turbidity Analyzer at CWR 441 PH Analyzer 442 Chlorine Analyzer 443 Cable 444 (i) Complete cabling upto 3 Pumps 445 Security Survelliance IP Camera with recorder (optional) 446 Installation, commissioning & testing 447 Local Control Station at WTP 448 CE/UL & BIS Certified industrial grade LED Monitor with latest configuration as per specification 449 Desktop / PC with i5/i7 processor for as per technical bid documents 450 CE/UL Certified 3 KVA UPS with batteries as per technical bid documents 451 Full development version of required TAGS SCADA Software with customization of software for LCS as per requirement as per spec. mentioned in technical bid documents. 452 CE/UL certified local control room PLC with redundant CPU & power supply at LCS in IP 54 enclouseras per spec. mentioned in technical bid documents. 453 GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & received data & gather from remote sites to control station, all accessories included signal enhancer anternna along with running expenses till DLP 454 CE/UL Certified firewall for network protection 455 SURGE PROTECTOR FOR ETHERNET communication protection. 456 CE/UL certified industrial grade Ethernet Swtich 457 Cannon/HP or equivalent Laser printer 1018 or equivalent 458 Security Survillance IP Camera with recorder (Optional) 459 Installation, Commissioning & testing including required furniture, A/C etc. 460 Trial & Run 461 03 Months trial & run
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
2.
Drinking Water Supply and Sanitation #8962396 Technical Bid
Procurement Of Rate Of Materials- 1 M079-Polythene Water Storage Tank Of Isi Mark ( E.G Sintex / Sinter / Himgiri / Gangotietc ) With Cover And Locking System 2 M193gi Pipe 50 Mm Dia ( Tata Or Equivalent Make ) 3 M337jute 4 M922g.M. Ferrules 5 ( I ) 8 Mm Dia Wt. Not Less Than 400 Gms 6 ( Ii ) 10 Mm Dia Wt. Not Less Than 400 Gms 7 ( Iii ) 15 Mm Dia Wt. Not Less Than 400 Gms 8 ( Iv ) 20 Mm Dia Wt. Not Less Than 600 Gms 9 ( V ) 25 Mm Dia Wt. Not Less Than 900 Gms 10 M923stop Cocks 11 ( I ) 15 Mm Brass Stop Cock Wt. Not Less Than 300 Gms 12 ( Ii ) 20 Mm Brass Stop Cock Wt. Not Less Than 400 Gms 13 ( Iii ) 25 Mm Brass Stop Cock Wt. Not Less Than 575 Gms 14 ( Iv ) 32 Mm Brass Stop Cock Wt. Not Less Than 850 Gms 15 ( V ) 40 Mm Brass Stop Cock Wt. Not Less Than 1.15 Kg 16 ( Vi ) 50 Mm Brass Stop Cock Wt. Not Less Than 2.15 Kg 17 ( Vii ) 15 Mm Dia C.I. Body Brass Working Part Stop Cock. 18 ( Viii ) 20 Mm Dia C.I. Body Brass Working Part Stop Cock. 19 ( Ix ) 25 Mm Dia C.I. Body Brass Working Part Stop Cock. 20 M924g.M. Full Way Valve 21 ( I ) 15 Mm Dia Wt. Not Less Than 300 Gms Without Wheel 22 ( Ii ) 20 Mm Dia Wt. Not Less Than 400 Gms Without Wheel 23 ( Iii ) 25 Mm Dia Wt. Not Less Than 500 Gms Without Wheel 24 ( Iv ) 32 Mm Dia Wt. Not Less Than 700 Gms Without Wheel 25 ( V ) 40 Mm Dia Wt. Not Less Than 1.0 Kg Without Wheel 26 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.4 Kg Without Wheel 27 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.8 Kg Without Wheel 28 ( Viii ) 80 Mm Dia Wt. Not Less Than 2.5 Kg Without Wheel 29 M925g.M. Non Return Valve Vertical 30 ( I ) 15 Mm Dia Wt. Not Less Than 150 Gms 31 ( Ii ) 20 Mm Dia Wt. Not Less Than 250 Gms 32 ( Iii ) 25 Mm Dia Wt. Not Less Than 375 Gms 33 ( Iv ) 32 Mm Dia Wt. Not Less Than 600 Gms 34 ( V ) 40 Mm Dia Wt. Not Less Than 700 Gms 35 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.0 Kg 36 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.20 Kg 37 ( Viii ) 80 Mm Dia Wt. Not Less Than 1.50 Kg 38 ( Ix ) 100 Mm Dia Wt. Not Less Than 1.80 Kg 39 M926g.M. Non Return Valve Horizontal 40 ( I ) 15 Mm Dia Wt. Not Less Than 150 Gms 41 ( Ii ) 20 Mm Dia Wt. Not Less Than 250 Gms 42 ( Iii ) 25 Mm Dia Wt. Not Less Than 375 Gms 43 ( Iv ) 32 Mm Dia Wt. Not Less Than 600 Gms 44 ( V ) 40 Mm Dia Wt. Not Less Than 700 Gms 45 ( Vi ) 50 Mm Dia Wt. Not Less Than 1.0 Kg 46 ( Vii ) 65 Mm Dia Wt. Not Less Than 1.20 Kg 47 ( Viii ) 80 Mm Dia Wt. Not Less Than 1.50 Kg 48 ( Ix ) 100 Mm Dia Wt. Not Less Than 1.80 Kg 49 M927 Cocks 50 ( I ) 15 Mm Dia G.M. Bib Cock Wt. Not Less Than 300 Gms 51 ( Ii ) 15 Mm Dia Brass Bib Cock Wt. Not Less Than 400 Gms 52 ( Iii ) 15 Mm Dia C.I. Bib Cock Wt. Not Less Than 400 Gms 53 ( Iv ) 15 Mm Dia C.I. Body Brass Working Part Spray Painted Bib Cock Wt. Not Less Than 400 Gms 54 ( V ) 15 Mm Dia C.I. Brass Pillar Cock Cock Wt. Not Less Than 400 Gms 55 ( Vi ) 15 Mm C.I. Plug Cock Ordinary 56 ( Vii ) 15 Mm C.I. Push Cock Ordinary 57 M928chromium Plated Brass Fittings 58 ( I ) C.P. Shower Rose 100 Mm Dia 59 ( Ii ) C.P. Shower Rose 125 Mm Dia 60 ( Iii ) P.V.C. Shower Rose 150 Mm Dia 61 ( Iv ) P.V.C Shower Rose 125 Mm Dia 62 M929connection Pipe 63 ( I ) 15 Mm Dia X 30 Cm. Long Lead Connection Pipe With Brass Fittings. 64 ( Ii ) 15 Mm Dia X 45 Cm. Long Lead Connection Pipe With Brass Fittings. 65 ( Iii ) 15 Mm Dia X 30 Cm. Long Pvc Connection Pipe With Brass Fittings. 66 ( Iv ) 15 Mm Dia X 45 Cm. Long Pvc Connection Pipe Withbrass Fittings. 67 M930g.I. Fittings ( Conforming To I.S. - 1879 ) Isi Marked 68 [ A ] G.I. Bend 69 ( I ) 15 Mm 70 ( Ii ) 20 Mm 71 ( Iii ) 25 Mm 72 ( Iv ) 32 Mm 73 ( V ) 40 Mm 74 ( Vi ) 50 Mm 75 ( Vii ) 65 Mm 76 ( Viii ) 80 Mm 77 ( Ix ) 100 Mm 78 ( X ) 125 Mm 79 ( Xi ) 150 Mm 80 [ B ] Elbow Of The Following Sizes 81 ( I ) 15 Mm 82 ( Ii ) 20 Mm 83 ( Iii ) 25 Mm 84 ( Iv ) 32 Mm 85 ( V ) 40 Mm 86 ( Vi ) 50 Mm 87 ( Vii ) 65 Mm 88 ( Viii ) 80 Mm 89 ( Ix ) 100 Mm 90 ( X ) 125 Mm 91 ( Xi ) 150 Mm 92 [ C ] Tee Plain Of The Following Sizes 93 ( I ) 15 Mm 94 ( Ii ) 20 Mm 95 ( Iii ) 25 Mm 96 ( Iv ) 32 Mm 97 ( V ) 40 Mm 98 ( Vi ) 50 Mm 99 ( Vii ) 65 Mm 100 ( Viii ) 80 Mm 101 ( Ix ) 100 Mm 102 ( X ) 125 Mm 103 ( Xi ) 150 Mm 104 [ D ] Reducing Tee Plain Of The Following Sizes ( Taking Larger Dimension ) 105 ( I ) 20 Mm 106 ( Ii ) 25 Mm 107 ( Iii ) 32 Mm 108 ( Iv ) 40 Mm 109 ( V ) 50 Mm 110 ( Vi ) 65 Mm 111 ( Vii ) 80 Mm 112 ( Viii ) 100 Mm 113 ( Ix ) 125 Mm 114 ( X ) 150 Mm 115 [ E ] Socket Plain Of The Following Size ( Taking Larger Dimension ) 116 ( I ) 15 Mm 117 ( Ii ) 20 Mm 118 ( Iii ) 25 Mm 119 ( Iv ) 32 Mm 120 ( V ) 40 Mm 121 ( Vi ) 50 Mm 122 ( Vii ) 65 Mm 123 ( Viii ) 80 Mm 124 ( Ix ) 100 Mm 125 ( X ) 125 Mm 126 ( Xi ) 150 Mm 127 [ F ] Reducing Socket Plain Of The Following Sizes ( Taking Larger Dimension ) 128 ( I ) 20 Mm 129 ( Ii ) 25 Mm 130 ( Iii ) 32 Mm 131 ( Iv ) 40 Mm 132 ( V ) 50 Mm 133 ( Vi ) 65 Mm 134 ( Vii ) 80 Mm 135 ( Viii ) 100 Mm 136 ( Ix ) 125 Mm 137 ( X ) 150 Mm 138 [ G ] Union Socket Of The Following Sizes 139 ( I ) 15 Mm 140 ( Ii ) 20 Mm 141 ( Iii ) 25 Mm 142 ( Iv ) 32 Mm 143 ( V ) 40 Mm 144 ( Vi ) 50 Mm 145 ( Vii ) 65 Mm 146 ( Viii ) 80 Mm 147 ( Ix ) 100 Mm 148 ( X ) 125 Mm 149 ( Xi ) 150 Mm 150 [ H ] Plugs Of The Following Sizes 151 ( I ) 15 Mm 152 ( Ii ) 20 Mm 153 ( Iii ) 25 Mm 154 ( Iv ) 32 Mm 155 ( V ) 40 Mm 156 ( Vi ) 50 Mm 157 ( Vii ) 65 Mm 158 ( Viii ) 80 Mm 159 ( Ix ) 100 Mm 160 ( X ) 125 Mm 161 ( Xi ) 150 Mm 162 [ I ] Jam Nuts Of The Following Sizes 163 ( I ) 15 Mm 164 ( Ii ) 20 Mm 165 ( Iii ) 25 Mm 166 ( Iv ) 32 Mm 167 ( V ) 40 Mm 168 ( Vi ) 50 Mm 169 ( Vii ) 65 Mm 170 ( Viii ) 80 Mm 171 ( Ix ) 100 Mm 172 ( X ) 125 Mm 173 ( Xi ) 150 Mm 174 [ J ] G.I. Nipple Of The Following Sizes 175 ( I ) 15 Mm Dia X 100 Mm Long 176 ( Ii ) 20 Mm Dia X 100 Mm Long 177 ( Iii ) 25 Mm Dia X 100 Mm Long 178 ( Iv ) 32Mm Dia X 100 Mm Long 179 ( V ) 40 Mm Dia X 100 Mm Long 180 ( Vi ) 50 Mm Dia X 100 Mm Long 181 ( Vii ) 65 Mm Dia X 100 Mm Long 182 ( Viii ) 80 Mm Dia X 100 Mm Long 183 ( Ix ) 100 Mm Dia X 100 Mm Long 184 [ K ] G.I. Pipes Midium ( Tata Mark ) Or Equivalent As Per Is-1239 ( Part-01 ) / 2004 Isi Marked / Medium Quality 185 ( I ) 15 Mm Dia 186 ( Ii ) 20 Mm Dia 187 ( Iii ) 25 Mm Dia 188 ( Iv ) 32 Mm Dia 189 ( V ) 40 Mm Dia 190 ( Vii ) 65 Mm Dia 191 M931mirrors 192 ( A ) Mirror Of 6 Mm Thick Plain Glass 600 Mm X 450 Mm Beveled Edge Mirror Includingc.P. Brass Revolving Fittings 3 Mm Plywood Boardand C.P. Hinges Etc.To Fix The Mirror 193 ( B ) -Do- 450 Mm X 300 Mm -Do- 194 M932 ( A ) Glass Shelf 600 Mm X 125 Mm With C.P. Brass Rail 195 ( B ) -Do- 450 Mm X 125 Mm -Do- 196 M933 ( A ) C.P. Brass Towel Rail 20 Mm X 600 Mm With Bracket All Complete 197 ( B ) Anodized Aluminum 20 Mm X 600 Mm Towel Rail Complete With Brackets 198 M934c.P. Brass Soap Dish Medium Quality With Screw Andhinges Etc. 199 M935c.P. Liquid Soap Solution Holder 200 M936vitreous White Glazed Indian Water Closet Of Hindustan / Parry Ware / Cera / Naycer Or Anyotherequivalent Make 201 ( A ) 580 Mm Long 202 ( B ) 510 Mm Long 203 ( C ) 450 Mm Long 204 ( D ) 510 Mm Long White Glazed Fiber I.W.C 205 M937pair Of Vetreous White Glazed Foot Rest Of Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 206 M93815 Liters Capacity Pull And Let Go High Level C.I. Cistern Complete With Ball Cock And A Pair Of Bracket 207 M939 ( A ) 12.5 Liters Lowdown C.I. Cistern 208 ( B ) 10.0 Liters Capacity P.V.C. Low Design Cistern 209 M940 ( A ) White Glazed Vitreous E.W.C With P Trap Orany Other Equivalent Make 210 ( B ) E.W.C With S Trap 400 Mm High Of Hindustan / Parry Ware / Cera / Naycear Or Any Other Equivalent Make 211 ( C ) Black / White Plastic Seat For E.W.C -Do- As Above. 212 M941 ( A ) White Glazed Vitreous Earthen Were Urinal Flat Back Of Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 600 Mm X 350 Mm Size 213 ( B ) -Do- Squatting Small 450 Mm X 350 Mm 214 ( C ) -Do- Squatting Large 600 Mm X 350 Mm 215 ( D ) White Glazed Vitreous Earthen Ware Urinal Standing Corner Size 600 Mm X 350 Mm Hindustan / Parryware / Cera / Naycer Or Any Other Equivalent Make 216 ( E ) Partition Plate For Urinal 25 X 13 Size 217 ( F ) 5 Liters C.I. Automatic Cistern With All P.V.C Fittings 218 M942white Glazed Vitreous Wash Hand Basin 550 Mm X 400Mm Size Of Hindustan / Parryware / Cera / Naycer Or Any Otherequivalent Make 219 M943white Glazed Vitreous Earthen Ware Kitchensinks Of Hindustan / Parryware / Cera / Nayceror Any Other Equivalent Make 220 ( A ) Kitchen Sink 600 Mm X 450 Mm X 200 Mm ( 24 X 18 X 8 ) 221 ( B ) Kitchen Sink 600 Mm X 450 Mm X 250 Mm ( 24 X 18 X 10 ) 222 ( C ) Lab Sink 450 Mm X 300 Mm X 150 Mm ( 18 X 12 X 6 ) 223 ( D ) Lab Sink 300 Mm X 250 Mm X 150 Mm ( 12 X 10 X 6 ) 224 M944drain Board 225 ( A ) 600 Mm X 450 Mm ( 24 X 18 ) 226 ( B ) 525 Mm X 450 Mm ( 21 X 18 ) 227 M945h.C.I. Pipes 228 ( A ) 50 Mm Dia Single Socket 6-0 ( With Ear Weight 13 Kg ) 229 ( B ) 80 Mm Dia Single Socket 6-0 ( With Ear Weight 18 Kg ) 230 ( C ) 100 Mm Dia Single Socket 6-0 ( With Ear Weight 23 Kg ) 231 ( D ) 150 Mm Dia Single Socket 6-0 ( With Ear Weight 30 Kg ) 232 ( E ) 50 Mm Dia Double Socket 6-0 ( With Ear Weight 14 Kg ) 233 ( F ) 80 Mm Dia Double Socket 6-0 ( With Ear Weight 19 Kg ) 234 ( G ) 100 Mm Dia Double Socket 6-0 ( With Ear Weight 25 Kg ) 235 ( H ) 150 Mm Dia Double Socket 6-0 ( With Ear Weight 13 Kg ) 236 ( I ) 50 Mm Dia Single Socket 3-0 ( With Ear Weight 7.25 Kg ) 237 ( J ) 80 Mm Dia Single Socket 3-0 ( With Ear Weight 10.5 Kg ) 238 ( K ) 100 Mm Dia Single Socket 3-0 ( With Ear Weight 13.75 Kg ) 239 ( L ) 150 Mm Dia Single Socket 3-0 With Ear 240 ( M ) 50 Mm Dia Single Socket 2-0 ( With Ear Weight 5.35 Kg ) 241 ( N ) 80 Mm Dia Single Socket2-0 ( With Ear Weight 8.00 Kg ) 242 ( O ) 100 Mm Dia Single Socket 2-0 ( With Ear Weight 10.10 Kg ) 243 ( P ) 150 Mm Dia Single Socket 2-0 With Ear 244 ( Q ) 50 Mm Dia Single Socket 1-0 ( With Ear Weight 3.4 Kg ) 245 ( R ) 80 Mm Dia Single Socket 1-0 ( With Ear Weight 5.50 Kg ) 246 ( S ) 100 Mm Dia Single Socket 1-0 ( With Ear Weight 7.60 Kg ) 247 ( T ) 150 Mm Dia Single Socket 248 M946h.C.I. Fittings. 249 ( I ) Plain Bend Of Following Size 250 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 2.75 Kg ) 251 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 3.5 Kg ) 252 ( C ) 100 Mm Dia ( Weight Without Ear And Socket 4.5 Kg ) 253 ( D ) 150 Mm Dia ( Weight Without Ear And Socket 4.5 Kg ) 254 ( Ii ) Bend With Door With Following Size 255 ( A ) 50 Mm Dia ( Wight Without Ear And Socket 2.75 Kg ) 256 ( B ) 80 Mm Dia ( Wight Without Ear And Socket 4.00 Kg ) 257 ( C ) 100 Mm Dia -Do- 5.5 Kg 258 ( D ) 150 Mm Dia -Do- 259 ( Iii ) Single Junction With Door Of Followings Sizes. 260 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 3.75 Kg ) 261 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 6.50 Kg ) 262 ( C ) 100 Mm Dia -Do- 9.50 Kg 263 ( D ) 150 Mm Dia -Do- 264 ( Iv ) Double Junction With Door Of Following Sizes. 265 ( A ) 50 Mm Dia -Do- 4.5 Kg 266 ( B ) 80 Mm Dia -Do- 7.00 Kg 267 ( C ) 100 Mm Dia -Do- 13.00 Kg 268 ( D ) 150 Mm Dia -Do- 269 ( V ) Heel Rest Bend Of Following Sizes 270 ( A ) 50 Mm Dia 271 ( B ) 80 Mm Dia 272 ( C ) 100 Mm Dia 273 ( D ) 150 Mm Dia 274 ( Vi ) Cowel Of Following Sizes 275 ( A ) 50 Mm Dia ( Weight Without Ear And Socket 2.25 Kg ) 276 ( B ) 80 Mm Dia ( Weight Without Ear And Socket 3.25 Kg ) 277 ( C ) 100 Mm Dia ( Weight Without Ear And Socket 3.25 Kg ) 278 ( D ) 150 Mm Dia -Do- 279 ( Vii ) 100 Mm Dia P Trap ( Wt Without Ear And Socket ) 8.5 Kg 280 ( Viii ) 100 Mm Dia P Trap ( Wt Without Ear And Socket ) 8.8 Kg 281 ( Ix ) 100 Mm X 80 Mm Floor Trap ( Weight Without Ear And Socket ) 4.00 Kg 282 ( X ) Pass Over 50 Mm X 150 Mm For 50 Mm Projection 283 ( Xi ) -Do- 100 Mm X 150 Mm For 100 Mm Projection 284 ( Xii ) Inverted Junction Single 100 Mm X 50 ( Weight Without Ear And Socket ) 9.0 Kg 285 ( Xiii ) Inverted Junction Double 100 Mm X 50 Mm X 50 Mm ( Weight Without Ear And Socket ) 12.0 Kg 286 ( Xiv ) H.C.I. Offset 80 Mm Projection Of The Following Size 287 ( A ) 50 Mm Dia ( Weight Without Ear And Socket ) 2.75 Kg 288 ( B ) 80 Mm Dia -Do- 3.50 Kg 289 ( C ) 100 Mm Dia -Do- 5.00 Kg 290 ( D ) 150 Mm Dia -Do- 291 ( Xv ) H.C.I. Socket Of Following Sizes 292 ( A ) 50 Mm Dia ( Weight Without Ear ) 1.50 Kg 293 ( B ) 80 Mm Dia ( Weight Without Ear ) 3.00 Kg 294 ( C ) 100 Mm Dia ( Weight Without Ear ) 4.50 Kg 295 ( D ) 150 Mm Dia ( Weight Without Ear ) -Do- 296 M947c.I. Cover With Frame For Manhole And Inspection Chamber 297 ( A ) 600 Mm X 450 Mm Size ( Wt. 39 Kg ) 298 ( B ) 600 Mm X 450 Mm Size ( Wt. 25 Kg ) 299 ( C ) 500 Mm X 450 Mm Size ( Wt. 25 Kg ) 300 M948c.I. Bracket Pair For W.H.B 301 ( A ) 550 Mm X 400 Mm Size ( 22 X 16 ) 302 ( B ) -Do- For 12.5 Liter Cistern 303 ( C ) -Do- For 600 Mm X 450 Mm ( 24 X 18 ) Sink 304 ( D ) 40 Mm X 60 Mm Ms Plate Bracket For Sink As Above 305 M949 ( A ) 32 Mm ( 1 1 / 4 ) C.P. Brass Waste For W.H.B 306 ( B ) 40 Mm ( 1 1 / 2 ) C.P. Brass Waste For W.H.B For Sink 307 ( C ) 32 Mm ( 1 1 / 4 ) C.P. Waste Of White Metal 308 ( D ) 40 Mm ( 1 1 / 2 ) C.P. Waste Of White Metal 309 M950 ( A ) 32 Mm ( 1 1 / 4 ) P.V.C. Waste Pipe 750 Mm Long ( 26 Long ) Withbrass Union For W H B 310 ( B ) 40 Mm ( 1 1 / 2 ) P.V.C. Waste Pipe 750 Mm Long ( 26 Long ) With Brass Union For W H B 311 M95132 Mm ( 1 1 / 4 ) P.V.C. Telescopic Flush Pipe With Brass Union For High Level Cistern 312 M952rubber Inserttion 3 Mm ( 1 / 8 ) Thick 313 M953pig Lead 314 M954yarn 315 M955rubber Gasket For D.I Pipe Of Good Quality 316 ( A ) 80 Mm 317 ( B ) 100 Mm 318 ( C ) 125 Mm 319 ( D ) 150 Mm 320 ( E ) 200 Mm 321 ( F ) 250 Mm 322 ( G ) 300 Mm 323 ( H ) 350 Mm 324 ( I ) 400 Mm 325 ( J ) 450 Mm 326 ( K ) 500 Mm 327 ( L ) 600 Mm 328 ( M ) 700 Mm 329 ( N ) 750 Mm 330 ( O ) 800 Mm 331 ( P ) 900 Mm 332 ( Q ) 1000 Mm 333 ( R ) 1200 Mm 334 M956cotton Waste 335 M957asbestos Suta ( Gland Packing ) 336 M958solvent Cement 337 M959hydrocloric Acid ( Sepecific Gravity 1.20 ) 338 M960cp & Pvc Fitting 339 ( I ) 32 Mm Dia C.P. Waste 340 ( Ii ) 32 Mm Dia Pv C Waste Pipe 750 Mm Long With Coupling 341 ( Iii ) 40 Mm Dia C.P. Waste 342 ( Iv 40 Mm Dia Pvc Waste Pipe 750 Mm Long With Coupling 343 ( V 100 Mm Dia Steel Jali 344 ( Vi ) 15 Mm Dia C.P. Nipple With Coupling ( Short Pieces ) 345 ( Vii ) 50 Mm Dia Pvc Pipe With Coupling 346 M961special Type Of C.P. Bath Room Fittings For V.I.P.Buildings ( Jal, Jaquar, Marc Or Equivalent Mark ) 347 ( I ) Pillar Cock ( Isi ) 348 ( Ii ) Pillar Cock ( Long Neck ) 349 ( Iii ) Bib Cock ( Isi ) 350 ( Iv ) Bib Cock ( Long Thread ) 351 ( V ) Angular Stop Cock 352 ( Vi ) Angular Stop Cock ( Long Thread ) 353 ( Vii ) Concealed Stop Cock Reduce ( Isi ) 354 ( Viii ) Concealed Stop Cock Heavy-Duty Extra Adjustable Wall Flange 355 ( Ix ) Long Body Bib Cock 356 ( X ) Swan Neck Tap With Left Hand Operating Knob 357 ( Xi ) Central Hole Basin Mixer ( Best Quality ) 358 ( Xii ) Wall Mixer With Telephonic Shower Arrangement 359 ( Xiii ) Wall Mixer With Provision For Over Head Shower With Elbow Coupling And Well Flange 360 ( Xiv ) Wall Mixer 3 In 1 System With Provision For Over Head Shower With Elbow Coupling And Wall Flange 361 ( Xv ) Sink Mixer With Swinging Casted Spout 362 ( Xvi ) Sink Cock With Swinging Casted Spout 363 ( Xvii ) 4 - Way Diverter For Concealed Fittings 364 ( Xviii ) Pressure Adjustable Shower With Revolving Joint 365 ( Xix ) Telephone Shower With Flexible Pipe 366 ( Xx ) Flush Cock With Wall Flange ( 25 Mm ) 367 ( Xxi ) Towel Rail 24 368 ( Xxii ) Towel Ring 369 ( Xxiii ) Soap Dish 370 ( Xxiv ) Tumbler Holder 371 ( Xxv ) Toilet Paper Holder 372 ( Xxvi ) Glass Shelf 22 373 ( Xxvii ) Corner Glass Shelf With Bracket 374 ( Xxviii ) Flush Valve Complete With 32 Mm Size Controlcock & Flange 375 M962c.I Special & Pvc Pipes 376 1. C.I Double Shocketted Fittings Bend Such As Bend, Tee, Taper, 377 ( A ) 80-200 Mm 378 ( B ) 250-700 Mm 379 ( C ) 700-1000 Mm 380 2. C.I Double Flange Fittings Such As Tee, Taper, Tailpiece, Bend Etc 381 ( A ) 80-200 Mm 382 ( B ) 250-700 Mm 383 ( C ) 700-1000 Mm 384 Spare Parts Of Hand Pump 385 M963hexagonal Bolt M12x1.75X40mm Long Common To Marks Ii & Iii 386 M964hexagonal Nut M12x1.75Mm 387 M965washer M12 ( 2.5Mm Thick ) 388 M966high Tensile Bolt M10x1.5X40mm Long. 389 M967nyloc Nut M10x1.5Mm 390 M968handle Axle ( Stainless Steel ) 391 M969washer For Handle Axle ( 4Mm Thick ) 392 M970ball Bearing 6204 Z 393 M971spacer For Handle. 394 M972chain With Coupling. 395 M973hexagonal Bolt For Front Cover M12x1.75Mm Long. 396 M974nitrile Rubber Cup Washer For Mark – Ii & Iii 397 M975nitrile Sealing Ring Mark – Ii 398 M976nitrile Rubber Seating Big For Lower Valve Mark-Ii 399 M977nitrile Rubber Seating Small For Upper Valve Mark-Ii. 400 M978hexagonal Rod Coupling M12x1.75X50mm Long. 401 M979pump Head Assembly ( G.I. ) With Front Cover, Bolt & Third Plate. 402 M980front Cover ( G.I. ) 403 M981handle Assembly ( G.I. ) 404 M982 ( A ) Water Tank Assemblyfor Mark – Ii ( G.I. ) 405 ( B ) Water Tank Assembly For Mark – Iii ( Vlom-65 ) 406 M983stand Assembly ( G.I. ) Normal. 407 M984stand Assembly ( Telescopic ) ( G.I ) . 408 M985connecting Rod 3Mtr. Long With Coupling And Nut ( Electrogalvanized ) 409 M986a ) Cylinder Assembly Complete Set For Mark-Ii 410 B ) Cylinder Assembly Complete Set For Mark-Iii ( Vlom-65 ) 411 M987a ) Upper Valve Assembly Complete Set For India Mark-Ii 412 B ) Upper Valve Assembly Complete Set For India Mark-Iii ( Vlom-65 ) 413 M988a ) Lower Valve Assembly Complete Set For India Mark-Ii 414 B ) Lower Valve Assembly Complete Set For Im-Iii 415 M989reducer Cap For Cylinder Mark-Ii 416 M990a ) Plunger Rod ( S.S. ) For Mark – Ii 417 B ) Plunger Rod ( S.S. ) For Mark – Iii 418 M991upper Valve Guide ( G.M. ) . 419 M992rubber Seat Retainer For Mark-Ii 420 M993third Plate For Head Assembly ( Galanized ) 421 M994cylinder Body With Brass Liner For Im-Ii With Reducer Cap For Top And Bottom. 422 M995gun Metal Spacer. 423 M996check Valve Guide Mark-Ii 424 M997a ) Check Valve Seat For Mark – Ii 425 B ) Check Valve Seat For Mark – Iii 426 M998nitrile Rubber “O” Ring ( Vlom-65 ) 427 M999push Rod For Mark – Iii ( S.S ) . 428 M1000check Nut For Push Rod ( S.S. ) . 429 M1001nitrile Rubber Cup Washer For Vlom-50 430 M1002nitrile Rubber Sealing Ring For Mark – Iii Vlom-65 431 M1003nitrile Rubber Seating Big For Lower Valve Mk-Ii 432 M1004nitrile Rubber Seating Big For Lower Valve M-Iii Vlom-65 ) 433 M1005nitrile Rubber Bobbin Vlom-50 434 M1006nitrile Rubber “O” Ring Vlom-50 435 M1007nitrile Rubber Cone For Vlom-50 436 M1008nitrile Rubber Cone For Vlom-65 437 M1009nitrile Rubber Centralizer 150Mm For ( Vlom-65 ) . 438 M1010nitrile Rubber Centralizer 125Mm For ( Vlom-65 ) . 439 M1011nitrile Rubber Centralizer 150Mm For ( Vlom-50 ) . 440 M1012nitrile Rubber Centralizer 125Mm For Vlom-50 441 M1013nitrile Rubber Centralizer 100Mm For Vlom-50 442 M1014water Tank Assembly Mark – Iii Vlom-50 443 M1015cylinder Assembly Complete Set For Mark – Iii ( Vlom-50 ) 444 M1016upper Valve Assembly Complete Set For Im-Iii ( Vlom-50 ) 445 M1017lower Valve Assembly Complete Set For Im-Iii ( Vlom-50 ) 446 M1018a ) Upper Cap Cylinder Mark – Iii ( Vlom-65 ) 447 B ) Upper Cap Cylinder Mark – Iii ( Vlom-50 ) 448 M1019a ) Bottom Cap For Mark – Iii ( Vlom-50 ) 449 B ) Bottom Capfor Mark – Iii ( Vlom-65 ) 450 M1020follower For Im-Iii 451 M1021cage For Mark-Iii 452 M1022s.S. Hexagonal Bolt M-6X25mm Long. 453 M1023basic Rate Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-2, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Ecommended For Use With Cylinder Assembly Suitable For Bore Well Dia 100 To 125Mm Casing Pipe. 454 M1024basic Rate Of Upvc Pipe 125Mm Dia Conforming To I.S.I. Latest Revision Is 12818 / 2016 Cml No. 5543459 455 M1025basic Rate Of 32Mm G.I. Pipe In 3 Mtrs. Length ( Medium ) With Seamless Socket As Per Relevent B.I.S. Specificationis 1239 ( Part-I ) / 2004 456 M1030rcc Esr 457 Designing ( Aesthetically ) , And Constructing Rcc Elevated Service Reservoirs Of Following Capacity With Rcc Staging Consisting Of Columns, Internal And External Bracings Spaced Vertically Not More Than 4.5 Metres Centre To Centre For Esr Having Capacity Upto 500 Cum And Not More Than 6M C / C For Esr Having Capacity Above 500 Cum Including Excavation In All Types Of Strata, Foundation Concrete, Cement Plaster With Water Proofing Compound To The In Side And Out Side Face Of The Container And Also Plaster With Plastic Paint In All Columns And Bracingsincluding Refilling Disposing Off The Surplus Stuff With In A Lead Of 50 Metres, All Labour And Material Charges Including Lowering, Laying, Erecting, Hoisting And Jointing Of Pipe Assembly Of Inlet, Outlet, Washout, Overflow And Bypass Arrangements As Per Departmental Design, Providing And Fixing Accessories Such As M.S. Ladder Out Side, Stainless Steel Lader In Contenor, C.I. Manhole Frame And Covers, Water Level Indicators, Lightening Conductor, G.I. Pipe Railing Around Walk Way And Top Slab, Providing Stair Case From Ground Level To Roof Level, M.S. Grill Gate Of 2M Height With Locking Arrangement Of Approved Design, B.B. Masonry Chambers For All Valves, Ventilating Shafts, Providing And Applying Three Coats Of Acrylie Emulsion With Silicon Edditives Paint To The Structure Incluingroof Slab, Epoxy Painting To Internal Surface And Anti-Termite Treatment For Under Ground Part Soft He Structure And Giving Satisfactory Water Tightness Test As Per I.S. Code. The Job To Include Painting Then Ame Of The Scheme And Other Details On Thereservoir As Per The Directions Of Engineer In - Charge. 458 Notes 459 The Design Of The Structure Be In Accordance With Relevant I.S. Specification ( I.S. 3370 - 1965 Or Revised. ) 460 The Design Shall Satisfy The Stipulations As Per I.S. 1893 -1984 And I.S.13920 / 1993 For Seismic Force And I.S.-11682 / 1985 For R.C.C. Staging Of Over Head Tanks. 461 For Design Having More Than 6 Columns, Suitable Bracing Is Obligatory. 462 Plain Round Mild Steel Bars Grade- I Conforming To I.S.432 Part-I Orhigh Yield Strength Deformed Bars Conforming To I.S. 1786 Or I.S. 1139 Shall Beused, Grade- I Imildsteel Bars Will Not Be Allowed 463 Irrespective Of The Type Of Foundation Proposed In The Design, One Set Of Bracing Be Provided At The Ground Level. 464 These Rates Include Providing M.S. Ladder For E.S.R.S Upto 2 Lakh Litres Capacity And Providing Spiral Stair Case For E.S.R. Above 2 Lakh Litres Capacity. 465 Staging Shall Have To Bede Signed With Stresses Of M-200 Concrete For Esr. However All Rcc Construction Should Be Donein M-250. Structures In Contact With Water Shall Be Designed & Casted In M-300 466 These Rates Are Including The Cost Of Up Lift Pressure If Any And Entire Dewatering During Execution. Incase Of Water Logging Are A Where Water Is Struck At Shallow Depth, Extra Provision Of Dewatering Shall Be Made As Per Site Condition. 467 All Conditions Given In The Member SecretaryS Circular No. Mjp / Ts-I / 350 / 1668 Dt. 2-8-97 And Mjp / S-I / 350 / 2127 Dt. 13-7-99 Shall Be Strictly Followed And Additional Cost, If Any, Due To These Conditions Is Included In The Rates Mentioned Below. 468 75 % Part Rate Shall Be Payable For Reinforcement Concrete And Plastering Items Of Containers Of E.S.R. Till Satisfactory Hydraulic Testing For Water Tightness Is Given; And Till That Work Shall Be Treated As Incomplete. 469 The Rates Indicated In The Table Are Excluding The Cost Of Pipes, Specials And Valves Required For Inlet, Outlet, Washout, Overflow And Bypass Arrangement. The Scope Of Work, However, Includes Cost Of Erecting, Laying And Jointing Of Pipe And Valves Including Cost Of Jointing Materials Upto 5 M Beyond Outer Face Of Outer Most Column ( Cost Of Pipe, Specials And Valves Is Taken As 10% Of The Cost Of Esr As Per Table ) . 470 For Esr Upto 500 Cum Capacity C.I. Double Flanged Pipes Upto 300 Mm Dia Shall Be Provided And C.I. Specials Shall Be Used. For Esr Above 500 Cum Capacity C.I. / M.S. Pipe Assembly With Minimum 8 Mm Thickness Upto 500 Mm Dia And Minimum 10 Mm Thickness Above 500 Mm Dia Can Be Used With Proper Anti-Corrosive Epoxy Treatment From In Side And Out Side. 471 Below Mentioned Rates Are For Foundation Swith Individual Footing With Bearing Capacity Of 20 Tonnes Per Square Metre. For Raft Foundations, These Rates Shall Be Increased By 7.5% Where Safe Bearing Capacity ( Sbc ) Is 5 Mt Per Sqm And By 5 % Where Sbc Is More Than 5Mt / Sqm And Upto 10 Mt / Sqm. This % Of5 % Or 7. 5 % Is Applicable For Estimation Of Amount Of Lumpsum Item Of Esr. For Extra Item Due To Change From Individual Foundation To Raft, Actual Increase In Concrete And Steel Be Paid As Per Relevant Dsr Item. 472 The Rate Shall Be Increased By 30 % For Bearing Piles Upto Depth Of 10 M And For Further Increased In Depth By 5 M Each, It Shall Be Increased By Another 10%. These Rates Are Applicable Where Raft Is Not Feasible. For Pile Foundations Sulphate Resistant Cement Shall Only Beused. Single Pile For The Column Is Not Permitted, Group Of Piles Shall Be Designed With Pile Cap For Each Column Of Esr. 473 The Rates Are Applicable For Staging Height Of 12 M. These Rates Shall Be Increased Or Decreased For Per Metre Variation In This Staging Height As Below : 474 12 To 16 M Staging - 2% Per Metre 475 16 To 20 M Staging - 3% Per Metre 476 20 M And Above - 4% Per Metre 477 For 17 M Staging Height, Percentage Calculation Will Be Like Below : 478 12 To 16 M --- 4 X 2 = 8% 479 16 & 17 M --- 1 X 3% = 3% Total = 11% 480 For 21 M Staging Height, Percentage Calculation Will Be Like Below : 481 12 To 16 M --- 4 X 2 = 8% 482 16 To 20 M --- 4 X 3% = 12% 483 20& 21 M --- 1 X 4% = 4% Total = 24% 484 Following Rates Are For Seismic Zone Iii. For Zone Iv, These Rates Shall Be Increased By 5% And For Zone Ii, These Rates Shall Be Decreased By 5%. Concerned Executive Engineer Shall Confirm The Seismic Zone For The Scheme From Seismic Zone Splan Before Estimation And Adopt Appropriate Rates As Per Actual Seismic Zones. ( Seismic Maps Attached In This Csr ) . 485 Notes 486 Conditions From Sr.No.1 To 10 Shall Form A Part And Parcel Of The Tender And Must Be Included In The Draft Tender Papers For Works Of R.C.C. E.S.R. 487 Conditions From Sr.No.11 To 16 Are For Estimation Purpose Only And Shall Not Appear In The Tender. 488 Rates For Rcc Esrs 489 Upto 25, 000 Litres 490 Cost Of 25, 000 Litres Capacity 491 Add For Capacity Above 25, 000 Upto 50, 000 Litres 492 Cost Of 50, 000 Litres Capacity 493 Add For Capacity Above 50, 000 Upto 75, 000 Litres 494 Cost Of 75, 000 Litres Capacity 495 Add For Capacity Above 75, 000 Upto 1, 00, 000 Litres 496 Cost Of 1, 00, 000 Litres Capacity 497 Add For Capacity Above 1, 00, 000 Upto 1, 50, 000 Litres 498 Cost Of 1, 50, 000 Litres Capacity 499 Add For Capacity Above 1, 50, 000 Upto 2, 00, 000 Litres 500 Cost Of 2, 00, 000 Litres Capacity 501 Add For Capacity Above 2, 00, 000 Upto 2, 50, 000 Litres 502 Cost Of 2, 50, 000 Litres Capacity 503 Add For Capacity Above 2, 50, 000 Upto 3, 00, 000 Litres 504 Cost Of 3, 00, 000 Litres Capacity 505 Add For Capacity Above 3, 00, 000 Upto 4, 00, 000 Litres 506 Cost Of 4, 00, 000 Litres Capacity 507 Add For Capacity Above 4, 00, 000 Upto 5, 00, 000 Litres 508 Cost Of 5, 00, 000 Litres Capacity 509 Add For Capacity Above 5, 00, 000 Upto 7, 50, 000 Litres 510 Cost Of 7, 50, 000 Litres Capacity 511 Add For Capacity Above 7, 50, 000 Upto 10, 00, 000 Litres 512 Cost Of 10, 00, 000 Litres Capacity 513 Add For Capacity Above 10, 00, 000 Upto 15, 00, 000 Litres 514 Cost Of 15, 00, 000 Litres Capacity 515 Add For Capacity Above 15, 00, 000 Upto 20, 00, 000 Litres 516 Cost Of 20, 00, 000 Litres Capacity 517 M1031rcc Gsr And Sump 518 Designing ( Aesthetically ) , And Constructing Rcc Ground Service Reservoirs / Rcc Sumps In M-300 Mix. Of Required Capacity Including Excavation In All Types Of Strata, Foundation Concrete, Container Walls, Bottom Slab Top Rcc Roof Slab / Or Dome, 20 Mm Thick Cement Plaster With Water Proofing Compound In Cm 1:3 Proportion. To Inside Face Of The Container, Including Epoxy Paint From Inside Including Refilling And Disposing Of Surplus Stuff Within Lead Of 50 M, All Labour And Material Charges, For Laying And Jointing Of Pipe Assembly For Inlet, Outlet Washout, Over Flow And Bye-Pass Arrangement Consisting Of C.I. / M.S. D / F. Pipes, Specials And Valves Of Given Diameters, Providing And Fixing Accessories Such As M.S. Ladder Inside And Outside, C.I. Manhole Frame And Cover, Water Top Slab, B.B. Masonry Chamber For All Valves, Ventilating Shafts, Including Giving Satisfactory Hydraulic Test And Water Tightness Test As Per Is Code And Providing Three Coat Of Cement Paints To All Expose Surface Of Structure Including Roof Surface Etc. Complete As Per Design Data, Criteria, Obligatory Requirements And Detailed Specifications. 519 Anti –Termite Treatment Shall Be Given For Under Ground Portion Of The Structure. 520 Notes 521 The Design Shall Be In Accordance With Various Relevant I.S. Specification ( I.S.456 / 2000, I.S.875-1987, I.S.3370-1965 Or Revised. ) 522 Only M.S. Bars Grade I Conforming To I.S. 432 Part-I Or High Yield Strength Deformed Bars Conforming To I.S. 1786 Or I.S.1139 Shall Be Used.Grade- Ii M.S. Bars Shall Not Be Used. 523 Entire Structure Shall Be In M-300 Only. 524 The Scope Of Pipe Assembly Work Shall Be Upto 5 Metre Beyond Out Side Face Of The Wall, Cost Of Pipes Valves And Specials Is Not Included In The Rate But Labour Cost For Laying And Jointing Is Included. 525 The G.S.R. / Sump Above 15 Lakh Litres Capacity Shall Be In Two Compartment. 526 The Job Includes Designing The Structure For Up Lift Pressure And Dewatering If Required During Entire Execution And Disposal Of Surplus Excavated Stuff Within Lead Of 50 Metres As Directed By Engineer-In-Charge. If Up Lifts Considered In Design, Then These Rates Shall Be Increased By 7.5%. 527 G.S.R. Outlets Shall Be With Bell Mouth Of Approved Pattern In Bottom Slab And Cost Of Designing Bell Mouth Is Included In The Rate. Sump Well Includes Cost Of Suction Pit Required At Bottom. 528 For Pipe Diameters Upto 300Mm Only Cipipes And Ci Specials Shall Be Used. For Pipe Diameters Above 300Mm, M.S. Pipes And Specials Minimum 10Mm Thick Shall Be Used With Proper Anti Corrosive Epoxy Treatment From Inside And Outside. 529 Cost Of Pump House Is Not Included In These Rates. 530 Above Rates Are Applicable For Seismic Zones 2, 3 And 4. 531 75% Part Rate Shall Be Payable For Reinforcement, Concrete And Plastering Items Of All Types Of G.S.R. Sand Sump Still Satisfactory Hydraulic Testing For Water Tightness Test Is Given And Till That Work Shall Be Treated As Incomplete. 532 10% Shall Be Added For Sump If Over Head Pump House Is Proposed. 533 Note: Conditions From Sr.No.1 To 11 Shall Form A Part And Parcel Of Tender And Must Be Included In The Draft Tender Papers For Work Of R.C.C .Gsrs And Sumps. 534 Rates For Rcc Gsrs And Sumps 535 Upto 25, 000 Litres 536 Cost Of 25, 000 Litres Capacity 537 Add For Capacity Above 25, 000 Upto 50, 000 Litres 538 Cost Of 50, 000 Litres Capacity 539 Add For Capacity Above 50, 000 Upto 75, 000 Litres 540 Cost Of 75, 000 Litres Capacity 541 Add For Capacity Above 75, 000 Upto 1, 00, 000 Litres 542 Cost Of 1, 00, 000 Litres Capacity 543 Add For Capacity Above 1, 00, 000 Upto 1, 50, 000 Litres 544 Cost Of 1, 50, 000 Litres Capacity 545 Add For Capacity Above 1, 50, 000 Upto 2, 00, 000 Litres 546 Cost Of 2, 00, 000 Litres Capacity 547 Add For Capacity Above 2, 00, 000 Upto 3, 00, 000 Litres 548 Cost Of 3, 00, 000 Litres Capacity 549 Add For Capacity Above 3, 00, 000 Upto 5, 00, 000 Litres 550 Cost Of 5, 00, 000 Litres Capacity 551 Add For Capacity Above 5, 00, 000 Upto 10, 00, 000 Litres 552 Cost Of 10, 00, 000 Litres Capacity 553 Addforcapacityabove10, 00, 000Upto15, 00, 000 Litres 554 Cost Of 15, 00, 000 Litres Capacity 555 Add For Capacity Above 15, 00, 000 Litres 556 Note: 10% Shall Be Added Over The Cost Of Gsr For Sump Where Over Head Pump House Is Proposed. 557 M1032unconventionalwater Treatment Plant 558 Designing ( Aesthetically ) , Providing And Constructinghigh Rate Unconventionalwatertreatmentplant I.E. Simplified Water Treatment Plant Consisting Of Civil Works Includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti-Termitetreatmenttoentirestructurebelowgroundlevel, Ceramic Tiles For Floring, Acrylic Emulsion With Silicon Additives Paint From Outside Stainless Steel Railing, Mechanicalandelectricalcomponentsofvarioussub-Worksasgivenbelow : Includingnecessaryhydraulic Testing, Structuraltesting And Trial For 3 Months, Etc. Completeas Directedbyengineer-In-Charge ( Turn-Key Job ) Works. 559 Aeration Fountain 560 Inlet Arrangements 561 Mixing Channel With Ventury Flume And Flow Measuring Arrangement 562 Inlet Channel 563 Flocculator- Conforming To I.S. 7208-1974 ( Type-C ) With Detention Period Of 30 Minutes 564 Tube Settlers-Designing, Fabricating And Constructing Tube Settlers With Square Or Any Other Shaped Tube Like Circular, Cheveron, Hexagonal Etc .Having Proven Performance 565 Rapid Sand Gravity Filters - All Valve Shall Be Glandless. 566 Filter House 567 Chemical House 568 Alum Tanks- 2Nos. With Mixing, Carrying And Dosing Arrangements With Piping. 569 100 Kg Chlorine Cylender For Capacity Upto 5Mld And Chlorine Tonner For Capacity Above 5 Mld. 570 Tcl Solution Tank With Mixing, Carrying And Dosing Arrangement With Piping. 571 Bypass Arrangement 572 External And Internal Electrification 573 Laboratory Equipments 574 Wash Water Tanks Of Capacity Equal To12 Minutes To Wash Specified Number Of Filter Beds At Time At 600 Lit / M2 / M Under Head Of 12M At Under Drain. 575 Wash Water Pumps With 100% Standby 576 Air Blowers Capable Of Delivering 600 Lmp Per Square Metre Of Free Air Of Filter Area At 0.4 Kg / Sqcm At The Under Drains ( 100 % Standby ) .Air Blowers Shall Be Adopted For Wtp Having Capacity More Than 3 Mld Only. Below 3 Mld Capacity, Air Blowers Shall Not Be Adopted. 577 Pure Water Sump Of Capacity Equal To 1 Hourpumping Capacity. 578 Pure Water Pump House Over The Sump / By The Side Of Sump. 579 Drainage Arrangements 580 Alum Store 581 Sanitary Block With Necessary Water Supply And Drainage Arrangements And Internalwbm Roads. 582 These Rates Are Applicable For Seismic Zones 2, 3 And 4. 583 Rates Given Below Are Inclusive Of Uplift Pressure If Any And Dewatering During The Entire Work. 584 All Rcc Structures Shall Be Constructed In M-250. Structures In Contact With Water Shall Be In M-300. 585 Unconventional Treatment Plants Less Than 1 Mld Capacity Shall Not Be Constructed. 586 All The Structural Steel Works / Fabrications Are To Be Provided With Application Of Hot Dip Zinc Coating According To Specification As Per Is 4759:1996 ( Reafirmed 2006 ) . 587 Note: Conditions From Sr. No. 1 To 28 Shall Form A Part And Parcel Of The Tender And Must Be Included In Draft Tender Papers For The Work Of Unconventional Treatment Plants. 588 Unconventional Water Treatment Plant 589 Fixed Cost For 1 Mld 590 Add For Capacity Above 1 Mld Upto 2 Mld 591 Cost Of 2 Mld Treatment Plant 592 Add For Capacity Above 2 Mld Upto 3 Mld 593 Cost Of 3 Mld Treatment Plant 594 M1033conventionalwater Treatment Plant 595 Designing ( Aesthetically ) , Providingconstructingandcommissioningconventionalwatertreatmentplantconsistingofallcivil, Mechanicalandelectricalworks Includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel, Mechanicalandelectricalcomponentsofvarioussub-Worksasgivenbelow, Includingnecessaryhydraulic Testing, Structuraltesting, Equipmenttestingandtrialrunfora Periodof3 Months, Etc. Completeas Directedbyengineer-In-Charge ( Turn-Key Job ) . 596 Aeration Fountain- Plan Are A Not Less Than 0.625 Square Metre Per Mld 597 Ventury Flume - With Necessary Devices, Consisting Of Simple Mechanical Indicator. ( Pedestal Type Gauge ) 598 Flash Mixer-Rapid Mixing Device, Detention Time 60 Seconds To Give Velocity Gradient 300 To 400 Sec -1, Vane Mixer Type Conforming To I.S. 7090 Of 1985. 599 Flocculator – Conforming To I.S.7208-1974 ( Type-C ) With Detention Period Of 30 Minutes. 600 Clarifier - Horizontal Flow Circular Tank, Detention Period 2-5 Hours, Overflow Rate 30 Cubic Metre Per Square Metre Per Day ( To Be Specified ) , Weir Loading Not More Than 300 Cubic Metre Per Metre Per Day, With Mechanical Sludge Scraper Conforming To I.S. No. 10313-1982. 601 Rapid Sand Filter Sand Filter House-Filter Designed For Filteration Rate Of 5, 000 Litres Per Square Metre Per Hour, Minimum 2 Beds For Plant Upto 10 Mld, For Larger Plants As Specified, Filters To Be Located In Filter House With Roof Slab, Pipe Gallery And Platform Minimum 5.5 Metre In Width. 602 Filtersand-Effective Size 0.45 To 0.70Mm, Uniformity Coefficient Not More Than 1.7, Nor Less Than 1.3, Depth Of Water Over Sand 0.75M, Free Board 50Cm, Gravel 0.45M In Depth, Sand And Gravel Conforming To I.S. 8491 ( I ) -77, Back Wash By Air Wash, Stand Ard Appurtenances ( To Be Specified ) , Rate Of Flow Controller, Filter Gauge, Sand Expansion Gauge, Etc. 603 Wash Water Tank-Capacity To Be Specified And Suitable To Supply Water To Wash 2 Filter Units At A Time Where The Units Are 4 Or More. 604 Wash Water Pumps- Capacity To Fill Water Tank In 1 Hour With 100% Standby. 605 Air Blowers-Capable Of Delivering 600 Lmp Per Square Metre Of Free Air, Of Filter Area At 0.4Kg / Sqcm At The Under Drains ( 100% Standby ) . 606 Chemical House In Two Storeys 607 Ground Floor To Accommodate 7 Days Alum Requirement And Sundry Storage. 608 First Floor To Accommodate Alum And Lime Tanks.Etc. 609 Solution Tanks-Minimum 3 Tanks ( One For Preparation, Second For Dosing And Third As Standby ) , Each Tank Capable Of Giving 8 Hours Maximum Dose Without Interruption, Minimum Free Board 0.30M, Trays For Dissolving, Level Indicator, Mechanical Agitation Devices, Solution Feed And Drain Lines, Solution Feed Device ( Constant Head Device, Strength Of Solution Upto 10% Only ) Conforming To I.S. 9222 Part-I 1979. 610 Pure Water Sump And Sump House. 611 Capacity Of Sump – One Hour Of Designed Flow. 612 Pump House- Pump House Of Required Size Over The Sump Or By The Side. 613 Store House-Suitable For Alum Storage Of Three Months Requirement In Monsoon With 10% Extra Capacity For Other Sundry Articles. 614 Vacuum Feed Type Chlorinators- Make Tobe Approved By Mjp. 615 Conforming To I.S. 10533 - A Part-Ii 1983 616 Rate For Withdrawal 617 Temperature Kg. Of Chlorine Discharge Degree C Per Day ( Cylinders ) 618 45 67Tonnes 619 10 6.359.50 110 620 15 10.75 16.10130 621 20 14.50 21.24254 622 27&Above18.70 28.12315 623 Chlorinator Equipment And Container Room To Conform To I.S. 10553 Part-I 1983. 624 100% Standby Shall Be Provided. 625 By Pass Arrangements - C.I. Or M.S. Pipes. 626 Disposal Of Waste From Wtp: Safe Disposal Arrangement To Near By Nala Including Cost Of Pipe 627 For Wtp Of Capacity 30 Mld And More Additional Arrangement For Backwash Water Recycle Shall Be Provided, Including Sump, Pupming Machinary, Rising Main Etc Complete 628 Drainage Arrangements – Rcc Pipes Up To Plot Boundary. 629 Electrical Installation – Both Internal And External Including Entire Plant Area. 630 Laboratory Equipment –As Per Requirement ( To Be Specified During Tendering ) . 631 Sanitary Blocks – Carpet Area -15 Square Metre Minimum Upto 25 Mld And 25 Square Metre Above 25 Mld. 632 Administrative Block And Internal Road-To Accommodate Office Room, Chlorine Room, Laboratory Room, Panel Board Room, Blower Room Etc. And Wbm Road To Connect All Units From Main Gate Of Plot. 633 Rates Given Below Are Inclusive Of Up Lift Pressure If Any And Dewatering During Entire Work. 634 All Pipes Condutes Channels With20%Overloading 635 These Rates Are Applicable For Seismic Zones 2, 3 And 4. 636 All Rcc Structures Shall Be Constructed In M-300. 637 Note: Conditions From Sr. No. 1 To 22 Shall Form A Part And Parcel Of The Tender And Must Be Incorporated In Draft Tender Papers Of Conventional Treatment Plants ( Proposed ) . 638 Conventional Water Treatment Plant 639 Above3 Mld To Upto 5 Mld 640 Cost Of 5 Mld Treatment Plant 641 Add For Capacity Above 5Mld Upto 10 Mld 642 Cost Of 10 Mld Treatment Plant 643 Add For Capacity Above 10 Mld Upto20 Mld 644 Cost Of 20 Mld Treatment Plant 645 Add For Capacity Above 20 Mld Upto 50 Mld 646 Cost Of 50 Mld Treatment Plant 647 Add For Capacityabove 50 Mld Upto 100 Mld 648 Cost Of 100 Mld Treatment Plant 649 Add For Capacity Above 100 Mld 650 M1034gpt / Hygpt :Drilling By Rotary Drill Machine Of Size 300Mm & 400Mm Dia With T.C. Drill Bit For Tubewells In All Kinds Of Soil Including Moorum, Hard Soil, Soil Mixed With Pebbles, Shingles, Compacted Soil, Clay, Soft And Decomposed Rock Etc, Up To 60 Meters Depth Including Reaming To Facilitate Smooth Lowering Of Casing Pipe Etc. As Per Specification And Direction Of E / I ( Basic Rates ) 651 300 Mm Dia For Gpt 652 400 Mm Dia For Hygpt 653 M1035hydt : Cost Of Drilling 200 Mm X 165 Mm X 125 Meter Deep Bore Well In All Kinds Of Soil And Rock In Rural Area For Installation Of Pump Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Materials, Tools, Drilling Rig, Air Compressor And Equipments, As Well As Fuel, Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To The Site ( Basic Rates ) 654 From 0-50 Meter 655 From 51-125 Meter 656 M1037dt :Basic Rates For 125 / 115 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil And Rock For Installation Of Hand Pump With Dth Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant, For Making 125 / 115 Mm Dia Boring Etc. And Cost Of Transporting Rig Machine And Other Vehicle Up To Site Of Work As Per Specification And Dirrection Of Engineer Incharge ( Basic Rates ) 657 Drillig Upto 30 Mtr Depth Below G. L. In Rural Area 658 Drilling Beyond 31 Mtr Upto 60 Mtr Below G. L. In Rural Area 659 M1038trenchless 660 Installation Of Product Pipe By Manual Pipe Jacking Method Including Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Manual Shielded Excation , Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 661 From 900 Mm To 1000 Mm Dia 662 In Soft Soil 663 In Hard Soil 664 In Sandy Soil 665 In Stone Soil 666 From 1000 Mm To 1200 Mm Dia 667 In Soft Soil 668 In Hard Soil 669 In Sandy Soil 670 In Stone Soil 671 Above 1200 Mm To 1500 Mm Dia 672 In Soft Soil 673 In Hard Soil 674 In Sandy Soil 675 In Stone Soil 676 Installation Of Product Pipe By Auger Boring Methodincluding Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Shielded Excavation , Through Auger Boring Process Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 677 Upto 300 Mm Dia 678 In Soft Soil 679 In Hard Soil 680 In Sandy Soil 681 In Stone Soil 682 Above300 Mm To 450 Mm Dia 683 In Soft Soil 684 In Hard Soil 685 In Sandy Soil 686 In Stone Soil 687 Above 450 Mm To 600 Mm Dia 688 In Soft Soil 689 In Hard Soil 690 In Sandy Soil 691 In Stone Soil 692 Above 600 Mm To 900 Mm Dia 693 In Soft Soil 694 In Hard Soil 695 In Sandy Soil 696 In Stone Soil 697 Installation Of Product Pipe By Guided Auger Boring Methodincluding Making Of Entry And Exit Pits All Related Civil Works Like Excavation , Shoring / Strutting Etc Shielded Excavation , Through Auger Boring Process Lowering Of Pipe Segments In The Jacking Pit Laying And Jointing Of Product Pipeline Through Jacking Process From The Jacking Pit And Restoration Of Site After Project Completion As Per The Instruction Of The Engineering -In - Charge All Complete Exept The Cost Of The Pipe Average Cover Of 1.5 Depth Below Gi ( Upto 100 Meter Installation Length ) 698 Upto 300 Mm Dia 699 In Soft Soil 700 In Hard Soil 701 In Sandy Soil 702 In Stone Soil 703 Above300 Mm To 450 Mm Dia 704 In Soft Soil 705 In Hard Soil 706 In Sandy Soil 707 In Stone Soil 708 Above 450 Mm To 600 Mm Dia 709 In Soft Soil 710 In Hard Soil 711 In Sandy Soil 712 In Stone Soil 713 Above 600 Mm To 900 Mm Dia 714 In Soft Soil 715 In Hard Soil 716 In Sandy Soil 717 In Stone Soil 718 M1039providing And Supplying Isi Mark Ci / D / F Reflux Valves ( Non Return Valves ) Of Following Dia Inspection Charges Unloading From Railway Wagon , Loading Into Truck Transportation Upto Department Stores / Site Unloading Stacking Etc. Complete Reflux Valve As Per Is 5312 Part I ( 1984 ) 719 Without Byepass Arrangement - Pn-1 720 50 Mm 721 65 Mm 722 80 Mm 723 100 Mm 724 125 Mm 725 150 Mm 726 200 Mm 727 250 Mm 728 300 Mm 729 350 Mm 730 400 Mm 731 450 Mm 732 500 Mm 733 600 Mm 734 700 Mm 735 750 Mm 736 800 Mm 737 900 Mm 738 1000 Mm 739 1100 Mm 740 1200 Mm 741 With Byepass Arrangement - Pn-1 742 50 Mm 743 65 Mm 744 80 Mm 745 100 Mm 746 125 Mm 747 150 Mm 748 200 Mm 749 250 Mm 750 300 Mm 751 350 Mm 752 400 Mm 753 450 Mm 754 500 Mm 755 600 Mm 756 700 Mm 757 750 Mm 758 800 Mm 759 900 Mm 760 1000 Mm 761 1100 Mm 762 1200 Mm 763 Without Byepass Arrangement - Pn-1.6 764 50 Mm 765 65 Mm 766 80 Mm 767 100 Mm 768 125 Mm 769 150 Mm 770 200 Mm 771 250 Mm 772 300 Mm 773 350 Mm 774 400 Mm 775 450 Mm 776 500 Mm 777 600 Mm 778 With Byepass Arrangement - Pn-1.6 779 50 Mm 780 65 Mm 781 80 Mm 782 100 Mm 783 125 Mm 784 150 Mm 785 200 Mm 786 250 Mm 787 300 Mm 788 350 Mm 789 400 Mm 790 450 Mm 791 500 Mm 792 600 Mm 793 Providing Double Flange Sluice Valve ( Size 50 Mm To 1200 Mm ) Confirming For Is - 2906 / 14846 Including Worn Gear Arrangements As Per Test Pressure Stailess Steel Spindle , Caps Transportation Etc. All Complete . 794 With Byepass Arrangement - Pn-1 795 50 Mm 796 65 Mm 797 80 Mm 798 100 Mm 799 125 Mm 800 150 Mm 801 200 Mm 802 250 Mm 803 300 Mm 804 350 Mm 805 400 Mm 806 450 Mm 807 500 Mm 808 600 Mm 809 700Mm 810 750 Mm 811 800 Mm 812 900 Mm 813 1000 Mm 814 1100 Mm 815 1200Mm 816 Without Byepass Arrangement - Pn-1 817 50 Mm 818 65 Mm 819 80 Mm 820 100 Mm 821 125 Mm 822 150 Mm 823 200 Mm 824 250 Mm 825 300 Mm 826 350 Mm 827 400 Mm 828 450 Mm 829 500 Mm 830 600 Mm 831 700Mm 832 750 Mm 833 800 Mm 834 900 Mm 835 1000 Mm 836 1100 Mm 837 1200Mm 838 Providing Double Flange Sluice Valve Confirming For Is - 2906 / 14846 Including Worn Gearas Per Test Pressure Stailess Steel Spindle , Caps Transportation Etc. All Complete For Rateincluding All Taxes . . 839 Without Byepass Arrangement - Pn-1.6 840 50 Mm 841 65 Mm 842 80 Mm 843 100 Mm 844 125 Mm 845 150 Mm 846 200 Mm 847 250 Mm 848 300 Mm 849 350 Mm 850 400 Mm 851 450 Mm 852 500 Mm 853 600 Mm 854 700Mm 855 750 Mm 856 800 Mm 857 900 Mm 858 1000 Mm 859 1100 Mm 860 1200Mm 861 With Byepass Arrangement - Pn-1.6 862 50 Mm 863 65 Mm 864 80 Mm 865 100 Mm 866 125 Mm 867 150 Mm 868 200 Mm 869 250 Mm 870 300 Mm 871 350 Mm 872 400 Mm 873 450 Mm 874 500 Mm 875 600 Mm 876 M1040design And Supply Of V -Wire Screen Laterals Suitable For Infiltration Galleryas Per Site Condition And Detail Provided End Connection Suitable Flange Excluding Taxes And Transportation . 877 Dia - 06 Inch ( 150 Mm ) 878 Id - 153 Mm Od -167 Mm 879 Screen Thickness - 07 Mm 880 Slot - 1.00 Mm 881 Moc - Lowcarbon Galvenised Steel 882 Length - 5 Mtr. 883 Dia - 08 Inch ( 200 Mm ) 884 Id - 205 Mm Od -221Mm 885 Screen Thickness - 08 Mm 886 Slot - 1.00 Mm 887 Moc - Lowcarbon Galvenised Steel 888 Length - 5 Mtr. 889 Dia - 10 Inch ( 250 Mm ) 890 Id - 256 Mm Od -276Mm 891 Screen Thickness - 10 Mm 892 Slot - 1.00 Mm 893 Moc - Lowcarbon Galvenised Steel 894 Length - 5 Mtr. 895 Dia - 12 Inch ( 300 Mm ) 896 Id - 306 Mm Od -326 Mm 897 Screen Thickness - 10 Mm 898 Slot - 1.00 Mm 899 Moc - Lowcarbon Galvenised Steel 900 Length - 5 Mtr. 901 Dia - 14 Inch ( 350 Mm ) 902 Id - 338 Mm Od -363 Mm 903 Screen Thickness - 12.5 Mm 904 Slot - 1.00 Mm 905 Moc - Lowcarbon Galvenised Steel 906 Length - 5 Mtr. 907 M1041supplying All Materials, Labours, Equipments For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Sides From Falling During The Process Of Drilling All Complete Including Carriage Of Materials To Work Site ( Basic Rate ) . 908 M1042supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Dirction E / I ( Basic Rate ) . 909 M1043supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting The Casing Pipe After Lowering In The Bore Including Carriage Of Materials To Work Site Etc. All Complete As Per Specification & Direction Of E / I ( Basic Rate ) . 910 M1044supplying Labour And Equipments Including 125Mm Dia G.I. Cap And Fitting And Fixing Over The Casing Pipe Of Tube Well Properly And Taking It Out As Per Direction E / I ( The Cap Will Be The Property Of Department ) ( Basic Rate ) . 911 M1045supplying All Materials, Labours, Equipments For Constructing P.C.C. ( 1:2:4 ) Circular Platform Around Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design, Etc. All Complete Including Carriage Of Materials ( Basic Rate ) . 912 M1046supplying All Materials, Labours And Equipments For Constructing P.C.C. ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete Including Carriage Of Materials ( Basic Rate ) . 913 M1047supplying Extra Deep Well Hand Pump Complete Sets With Cylinder Assembly & Connecting Rod ( 12 Pcs ) As Per Is : 15500 Part-2 / 2004 ( Basic Rate ) . 914 M1048supply Of 200Mm Dia X 3.00M Long Upvc Casing Pipe Conferming To Is : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 915 M1049supply Of 200Mm Dia Ribbed Screen Pipe Conferming Tois : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 916 M1050supply Of 125Mm Dia Ribbed Screen Pipe Conferming Tois : 12818: 2016 ( Cml No. 5543459 ) Latest Revision Including Carrigae ( Basic Rate ) . 917 M1051supplying All Tools, Equipments And Labour And Lowering 32 Mm Dia Medium Quality G.I. Pipe In Drilled Tube Well In 3 Mtrs. Length All Complete As Per Dirction E / I Including Carriage Of Materials ( Basic Rate ) . 918 M1052supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod Complete Job As Per Specification & Direction Of E / I Including Carriage Of Materials ( Basic Rate ) . 919 M1053supplying All Materials, Labours And Fixing India Mark Ii Hand Pump With All Accessories All Complete Job As Per Direction Of E / I Including Carriage Of Materials ( Basic Rate ) . 920 M1054design, Supply, Installation Testing & Commissioning Of Packaged Water Treatment Plants ( Unconventional Type ) Of Different Capacity With ( 20 Hours Operation ) Comprising Of Lamella Clarifier, Static Mixture Flocculation Tank ( Smet ) , Multi Grade Filter ( Mgf ) With Best Quality Filter Media, Lime / Coagulant / Polymer Dosing System Hypo Chloride Dosing System, Raw Water Feed Pump / Clear Water Transfer Pump ( Either Or ) , Sludge Transfer Cum Recirculation Pump, Filter Feed Pump & Back Wash Pump Including All Fitting Like Valve And Other Special Fittings And Electrical Power Supply To The Different Supplied Units With Mcb Panel Internal Electrification With Lighting Arrangement With Treatment Plant Site With Provision Of Chemical Storage And Water Testing Boratoryfacility Should Be From A Reputed Manufacturer / Authorized Distribution / Authorized Dealer Conforming To Relevant Is Codes And Certified By Iso-9001-2008 & 14001, It Also Include Cost Of Civil Foundation, Including Clarified Water Tank Internal Connecting Pipe Line From Raw Water Inlet To Cwr And Applying Internal Epoxy Paint On The Supply Equipment All The Prices Are Exclusive Of Gst, Allied Structure / Items Which Are Site Specific Such As External Electrification, Approach Road, Foot Bridge, Cofferdam, Compound Wall, Scada And Automation, Cwr Pumps Etc Are To Be Considered Extra. 921 0.2 Mld 922 0.3 Mld 923 0.4 Mld 924 0.5 Mld 925 0.6 Mld 926 M1055pumps 927 Supplying100 Mm Dia Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene / Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon / Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single / Double Run Shall Be Provided With Each Pump. 928 Submersible Pump Set 100 Mm Dia ( With Polypropylene / Noryl Impeller ) Up To 20 Stages 929 1 H.P. 930 1.5Hp 931 2 Hp 932 2.5 Hp 933 3.0 Hp 934 4.0 Hp 935 5.0 Hp 936 Supply Rate Should Be Increased By Rs 200 / - Per Stage For Pump With More Than 20 Stages 937 Submersible Pump 150 Mm Dia ( With Bronze Impeller ) Up To 8 Stages 938 1.5 Hp 939 2.0 Hp 940 3.0 Hp 941 4.0 Hp 942 5.0 Hp 943 6.0 Hp 944 7.5 Hp 945 Supply Rate Should Be Increased By Rs 600 / - Per Stage For Pump With More Than 8 Stages 946 Submersible Pump 150 Mm Dia ( With Bronze Impeller ) Up To 12 Stages 947 8.0 Hp 948 9.0 Hp 949 10.0 Hp 950 11.0 Hp 951 12.5 Hp 952 15.0 Hp 953 Supply Rate Should Be Increased By Rs 600 / - Per Stage For Pump With More Than 12 Stages 954 Submersible Pump 150 Mm Dia ( With Bronze Impeller ) Up To 20 Stages 955 17.5 Hp 956 20.0 Hp 957 25 Hp 958 1 ) Supply Rate Should Be Increased By Rs 600 / - Per Stage For Pump With More Than 20 Stages For Bore Well Only. 959 For Other Use 200 Mm Dia Pump Shall Be Preferred Over 150 Mm Dia With More Than 20 Stage Pump. 960 2 ) For 150 Mm Dia Energy Efficient Pumps Add As Below 961 A. Up To 8 Stages :- 3% On Supply Rate 962 B. Up To 12 Stages :- 4% On Supply Rate 963 C. Up To 15 Stages :- 5% On Supply Rate 964 M1056pressure Gauge 965 Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint 966 Pressure Gauge ( 100 Mm Dia ) 967 Pressure Gauge ( 150 Mm Dia ) 968 Vacuum / Combination Gauge 969 Supplyingvacuum Gauge / Combination Gauge Of Required Range Complete With Syphon Tube, Isolating Cock Suitable For 12 Mm Dia G.I. Pipe. 970 Vacuum / Combination Gauge – 100 Mm Dia 971 Vacuum / Combination Gauge – 150 Mm Dia 972 M1057lifting Equipment 973 Chain Pulley Block 974 Supplyingtriple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. 975 1 Tonne Capacity 976 2 Tonne Capacity 977 3 Tonne Capacity 978 Hand Operated Circular Or Rectangular Travelling Crane ( Single Girder ) 979 Supplyingsingle Girder Hand Operated Circular / Rectangular Travelling Crane With 6 M Lift Complete With Chain Pulley Block Isi Marked And Travelling Trolley Both Tested For 50% Overload Including Arrangement For Longitudinal Travel / Circular Travel And Cross Travel With Wheel, Hand Chain, Etc Complete. 980 3 Tonne Capacity 981 Up To 5 M Span 982 Above 5 M Up To 6 M Span 983 Above 6 M Up To 8 M Span 984 5 Tonne Capacity 985 Up To 5 M Span 986 Above 5 M Up To 6 M Span 987 Above 6 M Up To 8 M Span 988 Above 8 M Up To 10 M Span 989 Electric Operated Circular Or Rectangular Travelling Crane ( Single Girder ) 990 Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. 991 5 Tonne Capacity 992 Above 6 M Up To 8 M Span 993 Above 8 M Up To 10 M Span 994 7.5 Tonne Capacity 995 Above 6 M Upto 8 M Span 996 Above 8 M Up To 10 M Span 997 10 Tonne Capacity 998 Above 6 M Up To 8 M Span 999 Above 8 M Up To 10 M Span 1000 Square Bar / Rail 1001 Providing, Erecting And Fixing Square Bar Of En 8 As Rail For Over Head Crane On Provided Track, Girder / Continuous Corbel Beam, Including Supporting Plate And “J” Bolts. 1002 50 X 50 Mm ( En 8 ) 1003 40 X 40 Mm ( En 8 ) 1004 M1058lightening Arrester, Ab Switch, Insulators 1005 Lightening Arrestor 1006 Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. 1007 Suitable For 11 Kv Supply, Distribution Class 1008 Suitable For 22 Kv Supply, Distribution Class 1009 Suitable For 33 Kv Supply, Station Class 1010 Disc Insulator 1011 Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm 1012 Suitable For 11Kv Line 1013 Suitable For 33Kv Line 1014 Pin Insulator 1015 Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm 1016 Suitable For 11Kv Line 1017 Suitable For 33Kv Line 1018 Air Break Switch Without Earth Switch 1019 Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps 1020 Suitable For 11Kv Line 1021 Rocking / Tilting Type 1022 Rotating Type 1023 Suitable For 33Kv Line 1024 Rocking / Tilting Type 1025 Rotating Type 1026 Air Break Switch With Earth Switch 1027 Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps 1028 Suitable For 11Kv Line 1029 Rotating Type 1030 Suitable For 33Kv Line 1031 Rotating Type 1032 Drop Out Fuse ( Channel Mounted ) 1033 Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Currentup To 50 Amp, Capacity Completeerected On Provided Cross Arm, Each Set Comprising 3 Units 1034 Suitable For 11 Kv Line 1035 Suitable For 33 Kv Line 1036 Horn Gap Fuse ( Channel Mounted ) 1037 Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units 1038 Suitable For 11 Kv Line 1039 Suitable For 33 Kv Line 1040 M1059transformer 1041 Power Transformer ( With Off Load Tap Changer ) Any Isi Mark 1042 Supplyingoutdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 450 C By Thermometer In Oil And 500 C By Theresistance In Winding After Continuous Run At Full Load Rating, Thetransformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provideseparateearthing. The Transformer Shall Have Power Terminal Arrangement, Bushing / Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- 1043 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 1044 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 1045 3. Oil Drain Valve 1046 4. Oil Filter Valve 1047 5. Lifting Eyes / Hooks 1048 6. Two Earthing Terminals 1049 7. Diagram And Rating Plate 1050 8. Air Vent 1051 9. Explosion Vent 1052 10. 100Mm Dia Thermo Meter With Thermometer Pocket 1053 11. Four Bi Directional Plain Roller. 1054 Power Transformer 11000 / 433 Volts With Off Load Tap Changer – 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. 1055 63 Kva ( No Load Loss 180W And Load Loss 1235W ) 1056 100 Kva ( No Load Loss 260W And Load Loss 1760W ) 1057 160Kva ( No Load Loss 260W And Load Loss 1760W ) 1058 200Kva ( No Load Loss 500W And Load Loss3000w ) 1059 250Kvaa ( No Load Loss 550W And Load Loss3600w ) 1060 315Kva ( No Load Loss 580W And Load Loss 4200W ) 1061 400 Kva ( No Load Loss 715W And Load Loss 5000W ) 1062 500 Kva ( No Load Loss 850W And Load Loss 5800W ) 1063 630 Kva ( No Load Loss 1000W And Load Loss 7000W ) 1064 750 Kva ( No Load Loss 1500W And Load Loss 8000W ) 1065 Power Transformer ( With On Load Tap Changer ) 1066 Supplyingoutdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 450 C By Thermometer In Oil And 500 C By Theresistance In Winding After Continuous Run At Full Load Rating, Thetransformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provideseparateearthing. The Transformer Shall Have Power Terminal Arrangement, Bushing / Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- 1067 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 1068 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 1069 3. Oil Drain Valve 1070 4. Oil Filter Valve 1071 5. Lifting Eyes / Hooks 1072 6. Two Earthing Terminals 1073 7. Diagram And Rating Plate 1074 8. Air Vent 1075 9. Explosion Vent 1076 10. 100Mm Dia Thermo Meter With Thermometer Pocket 1077 11. Four Bi Directional Plain Roller. 1078 12. Buchholz Relay 1079 13. Resistance Temp. Detector 1080 14. Marshalling Box 1081 15. Automatic Voltage Regulator ( Avr ) 1082 16. Remote Tap Changing Controller ( Rtcc ) 1083 Transformer 11000 / 433 Volts Withon Load Tap Changer – 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification As Per Bis Level-2. 1084 750 Kva 1085 1000 Kva 1086 1250 Kva 1087 1600 Kva 1088 2000 Kva 1089 M1060motors 1090 Foot Mounted Motors Tefc 1500 Rpm 1091 Supplyingfoot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts + / -10%, 3 Phase, 50 Hz + / -3% With “F” Class Insulation Temperature Rise Limited To Class “B” Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. 1092 15 Kw ( 20 Hp ) 1093 18.5 Kw ( 25 Hp ) 1094 22 Kw ( 30 Hp ) 1095 30 Kw ( 40 Hp ) 1096 37 Kw ( 50 Hp ) 1097 45 Kw ( 60 Hp ) 1098 55 Kw ( 75 Hp ) 1099 75 Kw ( 100 Hp ) 1100 90 Kw ( 120 Hp ) 1101 110 Kw ( 150 Hp ) 1102 132Kw ( 180Hp ) 1103 160Kw ( 215 Hp ) 1104 250Kw ( 335 Hp ) 1105 Foot Mounted Motor Tefc 1500 Rpm 1106 0.75 Kw ( 1Hp ) 1107 1.1 Kw ( 1.5 Hp ) 1108 1.5 Kw ( 2 Hp ) 1109 2.2 Kw ( 3 Hp ) 1110 3.7 Kw ( 5 Hp ) 1111 5.5 Kw ( 7.5 Hp ) 1112 7.5 Kw ( 10 Hp ) 1113 9.3 Kw ( 12.5 Hp ) 1114 11 Kw ( 15 Hp ) 1115 M1061aluminium Cable 1116 Cable 1117 Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . 1118 Supplyingxlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1119 3 Core 2.5 Sq Mm 1120 3 Core 4 Sq Mm 1121 3 Core 6 Sq Mm 1122 3 Core 10 Sq Mm 1123 3 Core 16 Sq Mm 1124 3 Core 25 Sq Mm 1125 3 Core 35 Sq Mm 1126 3 Core 50 Sq Mm 1127 3 Core 70 Sq Mm 1128 3 Core 95 Sq Mm 1129 3 Core 120 Sq Mm 1130 3 Core 150 Sq Mm 1131 3 Core 185 Sq Mm 1132 3 Core 240 Sq Mm 1133 3 Core 300 Sq Mm 1134 3 Core 400 Sq Mm 1135 Aluminium Conductor 3.5 Core, Xlpe / Pvc Insulated & Unarmoured Cable 1136 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three And Half Core, Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Completein An Approved Manner. 1137 3.5 Core 25 Sq Mm 1138 3.5 Core 35 Sq Mm 1139 3.5 Core 50 Sq Mm 1140 3.5 Core 70 Sq Mm 1141 3.5 Core 95 Sq Mm 1142 3.5 Core 120 Sq Mm 1143 3.5 Core 150 Sq Mm 1144 3.5 Core 185 Sq Mm 1145 3.5 Core 240 Sq Mm 1146 3.5 Core 300 Sq Mm 1147 3.5 Core 400 Sq Mm 1148 Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated 1149 Supplying Ht Aluminium Three Core Cable Xlpe Insulated , Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0.3 Ka For 1 Sec. ) Cores Laidup Inner Sheath Of Pvc Tape , Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is :7098 / Ii / 85 With Latest Amendments 1150 3 Core 35 Sq Mm 1151 3 Core 50 Sq Mm 1152 3 Core 70 Sq Mm 1153 3 Core 95 Sq Mm 1154 3 Core 120 Sq Mm 1155 3 Core150sq Mm 1156 3 Core 185 Sq Mm 1157 3 Core 240Sq Mm 1158 3 Core 300 Sq Mm 1159 3 Core 400 Sq Mm 1160 Ht Aluminium Three Core 6.6 Kv ( Ue ) / 11Kv Ecable Xlpe Insulated 1161 Supplying Ht Aluminium Three Core Cable Xlpe Insulated , Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0.3 Ka For 1 Sec. ) Cores Laidup Inner Sheath Of Pvc Tape , Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is :7098 / Ii / 85 With Latest Amendments 1162 3 Core 35 Sq Mm 1163 3 Core 50 Sq Mm 1164 3 Core 70 Sq Mm 1165 3 Core 95 Sq Mm 1166 3 Core 120 Sq Mm 1167 3 Core150sq Mm 1168 3 Core 185 Sq Mm 1169 3 Core 240Sq Mm 1170 3 Core 300 Sq Mm 1171 3 Core 400 Sq Mm 1172 Ht Aluminium Three Core 11Kv ( Ue ) Cable Xlpe Insulated 1173 Supplying Ht Aluminium Three Core Cable Xlpe Insulated , Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape ( 0.3 Ka For 1 Sec. ) Cores Laidup Inner Sheath Of Pvc Tape , Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is :7098 / Ii / 85 With Latest Amendments 1174 3 Core 35 Sq Mm 1175 3 Core 50 Sq Mm 1176 3 Core 70 Sq Mm 1177 3 Core 95 Sq Mm 1178 3 Core 120 Sq Mm 1179 3 Core150sq Mm 1180 3 Core 185 Sq Mm 1181 3 Core 240Sq Mm 1182 3 Core 300 Sq Mm 1183 3 Core 400 Sq Mm 1184 Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable . 1185 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1186 3 Core 4 Sq Mm 1187 3 Core 6 Sq Mm 1188 3 Core 10 Sq Mm 1189 3 Core 16 Sq Mm 1190 3 Core 25 Sq Mm 1191 3 Core 35 Sq Mm 1192 3 Core 50 Sq Mm 1193 3 Core 70 Sq Mm 1194 3 Core 95 Sq Mm 1195 3 Core 120 Sq Mm 1196 3 Core 150 Sq Mm 1197 3 Core 185 Sq Mm 1198 3 Core 240 Sq Mm 1199 3 Core 300 Sq Mm 1200 3 Core 400 Sq Mm 1201 M1062copper Cable 1202 Cable 1203 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . 1204 Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . 1205 3 Core 1.5 Sq Mm 1206 3 Core 2.5 Sq Mm 1207 3 Core 4 Sq Mm 1208 3 Core 6 Sq Mm 1209 3 Core 10 Sq Mm 1210 3 Core 16 Sq Mm 1211 3 Core 25 Sq Mm 1212 3 Core 35 Sq Mm 1213 Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable . 1214 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1215 3 Core 1.5 Sq Mm 1216 3 Core 2.5 Sq Mm 1217 3 Core 4 Sq Mm 1218 3 Core 6 Sq Mm 1219 3 Core 10 Sq Mm 1220 3 Core 16 Sq Mm 1221 3 Core 25 Sq Mm 1222 3 Core 35 Sq Mm 1223 3 Core 50 Sq Mm 1224 3 Core 70 Sq Mm 1225 3 Core 95 Sq Mm 1226 Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . 1227 Supplyingxlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Completein An Approved Manner. 1228 3.5 Core 1.5 Sq Mm 1229 3.5 Core 2.5 Sq Mm 1230 3.5 Core 4 Sq Mm 1231 3.5 Core 6 Sq Mm 1232 3.5 Core 10 Sq Mm 1233 3.5 Core 16 Sq Mm 1234 3.5 Core 25 Sq Mm 1235 3.5 Core 35 Sq Mm 1236 3.5 Core 50 Sq Mm 1237 3 .5 Core 70 Sq Mm 1238 3.5 Core 95 Sq Mm 1239 3.5 Core 120 Sq Mm 1240 3 .5 Core150sq Mm 1241 3.5 Core 185 Sq Mm 1242 3.5 Core 240Sq Mm 1243 3.5 Core 300 Sq Mm 1244 3.5 Core 400 Sq Mm 1245 Copper Conductor 3.5 Core Xlpe / Pvcunarmoured 1246 Supplyingxlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1247 3.5Core 25 Sq Mm 1248 3.5Core 35 Sq Mm 1249 3.5 Core 50 Sq Mm 1250 3.5 Core 70 Sq Mm 1251 3.5 Core 95 Sq Mm 1252 3.5 Core 120 Sq Mm 1253 3.5 Core150sq Mm 1254 3.5 Core 185 Sq Mm 1255 3.5 Core 240Sq Mm 1256 3.5 Core 300 Sq Mm 1257 3.5 Core 400 Sq Mm 1258 Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . 1259 Supplyingxlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 1260 3 Core 1.5 Sq Mm 1261 3 Core 2.5 Sq Mm 1262 3 Core 4 Sq Mm 1263 3 Core 6 Sq Mm 1264 3 Core 10 Sq Mm 1265 3 Core 16 Sq Mm 1266 3 Core 25 Sq Mm 1267 3 Core 35 Sq Mm 1268 3 Core 50 Sq Mm 1269 3 Core 70 Sq Mm 1270 3 Core 95 Sq Mm 1271 3 Core 120 Sq Mm 1272 3 Core 150Sq Mm 1273 3Core 185 Sq Mm 1274 3 Core 240 Sq Mm 1275 3 Core 300 Sq Mm 1276 3 Core 400 Sq Mm 1277 M1063foot Valve 1278 Foot Valve 1279 Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. 1280 Flanged Type 1281 50 Mm 1282 65 Mm 1283 80 Mm 1284 100 Mm 1285 125 Mm 1286 150 Mm 1287 M1064aircircuit Breaker 1288 Acbbreaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole 1289 630A 1290 800A 1291 1000A 1292 1250A 1293 1600A 1294 2000A 1295 M1065starter 1296 D.O.L. Starter With Ss Enclosure With 380 / 415 Volt Coil 1297 7.5 H.P. 1298 10 H.P. 1299 Supplyingfully Automatic Star Delta Starter To Operate Induction Motor Working On415v, 3Phase, 50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser 1300 F.A.S.D Starter 1301 10.0 H.P. 1302 15 H.P. 1303 20 H.P. 1304 25 H.P. 1305 35 H.P. 1306 40 Hp 1307 50 Hp 1308 75 H.P. 1309 100 H.P. 1310 125 H.P. 1311 150 H.P. 1312 250 H.P. 1313 M1066servo Controlled Automatic Voltage Stabilizer 1314 Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt + / -1%, 3 Ph, 50 Hz, With Copper Wound Transformer ( Air / Oil Cooled ) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And UserS Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto / Manual Selector Switch, Raise / Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated?? Over Voltage / Under Voltage?? Single Phasing?? Cut Off Contactor With Electronic Output Sensing Unit 1315 Servo Controlled Automatic Voltage Stabiliser ( Out Put 415 + / -1% ) Input 150 To 450 Volt 1316 20 Kva Air Cooled 1317 25 Kva Air Cooled 1318 30 Kva Air Cooled 1319 40 Kva Air Cooled 1320 50 Kva Oil Cooled 1321 60 Kva Oil Cooled 1322 75 Kva Oil Cooled 1323 100 Kva Oil Cooled 1324 125 Kva Oil Cooled 1325 Servo Controlled Automatic Voltage Stabiliser ( Out Put 415 + / -1% ) Input 280 To 460 Volt 1326 15 Kva Air Cooled 1327 20 Kva Air Cooled 1328 25 Kva Air Cooled 1329 30 Kva Air Cooled 1330 40 Kva Air Cooled 1331 50Kva Air Cooled 1332 60 Kva Oil Cooled 1333 75Kva Oil Cooled 1334 100 Kva Oil Cooled 1335 125 Kva Oil Cooled 1336 150 Kva Oil Cooled 1337 200Kva Oil Cooled 1338 250Kva Oil Cooled 1339 300 Kva Oil Cooled 1340 400 Kva Oil Cooled 1341 M1067termination Kit 1342 Providing And Errecting In-Door Type Termination Kit, For 3.3Kv / 6.6 Kv / 11Kv / 22Kv / 33Kv Xlpe Screened 3 Core Cable 1343 In-Door Termination Kit For 3.3Kv ( E / Ue ) / 6.6 Kv ( E ) Xlpe 3 Core Cable 1344 25-50 Mm2 1345 70-120 Mm2 1346 150-185 Mm2 1347 240-400 Mm2 1348 Out-Door Termination Kit For 3.3 ( E / Ue ) / 6.6 Kv ( E ) Xlpe 3 Core Cable 1349 25-50 Mm2 1350 70-120 Mm2 1351 150-185 Mm2 1352 240-400 Mm2 1353 Straight Through Joint For 3.3Kv ( E / Ue ) / 6.6 Kv ( E ) Xlpe 3 Core Cable 1354 25-50 Mm2 1355 70-120 Mm2 1356 150-185 Mm2 1357 240-300 Mm2 1358 In Door Termination Kit For 11Kv ( E ) Xlpe Screened 3 Core Cable 1359 25-50 Mm2 1360 70-120 Mm2 1361 150-185 Mm2 1362 240-400 Mm2 1363 Out Door Termination Kit For 11Kv ( E ) Xlpe Screened 3 Core Cable 1364 25-50 Mm2 1365 70-120 Mm2 1366 150-185 Mm2 1367 240-400 Mm2 1368 Straight Through Joint For 11 Kv ( E ) Xlpe Screened 3 Core Cable 1369 25-50 Mm2 1370 70-120 Mm2 1371 150-185 Mm2 1372 240-300 Mm2 1373 In Door Termination Kit For 22Kv ( E ) Xlpe Screened 3 Core Cable 1374 25-50 Mm2 1375 70-120 Mm2 1376 150-185 Mm2 1377 240-400 Mm2 1378 Out Door Termination Kit For 22Kv ( E ) Xlpe Screened 3 Core Cable 1379 25-50 Mm2 1380 70-120 Mm2 1381 150-185 Mm2 1382 240-400 Mm2 1383 Straight Through Joint For 22 Kv ( E ) Xlpe Screened 3 Core Cable 1384 25-50 Mm2 1385 70-95 Mm2 1386 120-150 Mm2 1387 185-240 Mm2 1388 300-400 Mm2 1389 In Door Termination Kit For 33Kv ( E ) Xlpe Screened 3 Core Cable 1390 25-50 Mm2 1391 70-95 Mm2 1392 120-185 Mm2 1393 240-400 Mm2 1394 Out Door Termination Kit For 33 Kv ( E ) Xlpe Screened 3 Core Cable 1395 25-50 Mm2 1396 70-95 Mm2 1397 120-185 Mm2 1398 240-400 Mm2 1399 Straight Through Joint For 33 Kv ( E ) Xlpe Screened 3 Core Cable 1400 35-70 Mm2 1401 95-150 Mm2 1402 185-300 Mm2 1403 400 Mm2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
3.
Defence #8184022 AOC
Tender For Replacement Of Water Supply Pipe Line Inside Cantt 600000 Gallon Water Treatment Plant At 20 Camp Pump House Under Ge Ramgarh; 2 SCHEDULE A PART-I A (Building Work)Design (Hydraulically, architecturally, structurally and aesthetically) and construction of underground sump of 30000 gallon (UK) capacity including with permanent specification RCC M30 (Design Mix) excavation in all type of strata foundation concrete container walls, bottom lab, local sump & foundation for pump/pipes, top RCC roof slab with C manhole covers, all surfaces are plaster with WPC including epoxy paint inside (bottom & sides) including all pipeline connections, valves, MS ladder, ventilation shaft and testing of water tightness and hydraulic functioning complete and necessary internal water supply & electrical suplly. Arch drawing of sump and WTP (site plan) approved by CWE/GE 3 Sch A Part-I B (Water Treatment Plant)Design (Architecturally, hydraulically, aesthetically and structurally), construting, commissioning and testing of water treatment plant 600000 gallons complete all as specified and directed. 4 NOTE : The basic requrement of Water Treatment Plant is as under for guidline :Design (Architecturally, hydraulically, aesthetically and structurally), construting, commissioning and testing of conventional water treatment plant 600000 gallons including cost of providing and applying epoxy paint to inside surface of water retaining structure in contact with chlorine and providing anti termite treatment to entire structure below ground level, Mechanical and electrical components of various sub-works as specifiedin scope of work, Design Basis Report, elsewhere in tender : including necessary hydraulic testing, structural testing, equipment testing and trial run for 03 months etc. complete including all pumping machinery all as specified and directed by Engr-in-charge and as per latest technolony and govt & this dept policy for portable water treatment plant. Treated water parameters for drinking water is as per IS 10500 :2012(Second Revision). Raw water value is enclosed as appx A 5 Sch A Part-II (External Water supply)Lump sum price worked out by the contractor for ExternalWater Supply as listed in Schedule A Part-II against the lump sum price inserted by the MES. 6 Sch A Part-III(Road, Path and Culvert)Lump sum price worked out by the contractor for Road Path and Culvert as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 7 Sch A Part-IV(Sewage Disposal)Lump sum price worked out by the contractor for Sewage Disposal as listed in Schedule A Part-V against the lump sum price inserted by the MES. 8 Sch A Part-V(Demolition & Dismantling)Lump sum price worked out by the contractor for Demolition & Dismantling as listed in Schedule A Part-VII against the lump sum priceinserted by the MES. 9 Sch A Part-VI(Site clearance, excavation & earth works)Lump sum price worked out by the contractor for Site clearance, excavation & earth works as listed in Schedule A Part-VII against the lump sum priceinserted by the MES. 10 Note for Srl No 2 to 9The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 9by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 11 Schedule A Part-VII (Miscellaneous works) 12 Sewage Disposal 13 Item No 01 : Soakage wells 1.20 M dia X 3.0 M effective depth, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 40 mm to 63 mm as specified and directed.(Drg No. BTD - 744) 14 Item No 02 : M&L for LDPE septic tank designed to carry sewage and sullage water, with upflow filter incoming media excavation in any type of soil, PCC 1:4:8 below foundation, etc with vent shaftof 10 users complete all as per manufacturer instructions. 15 External Water Supply 16 Item No 03 : Supply, Laying in trenches 150 mm nominal diaductile iron pressure pipe, for water mains centrifugally cast with spigot and socket ends (for push on joints), Class K-9 of standard length 5.5 mtr complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately. 17 Item No 04 : All as per item No 03 here-in-before but 200 mm dia 18 Item No 05 : All as per item No 03 here-in-before but 250 mm dia 19 Item No 06 : M & L for rubber gasket joints (push on joints) for spigot/ socket end ductile iron water mains/ductile iron specials complete for 150 mm nominal dia complete all as specified and as directed. 20 Item No 07 : All as per item No 06 here-in-before but 200mm dia 21 Item No 08 : All as per item No 06 here-in-before but 250mm dia 22 Item No 09 : Supply and fix DI special suitable for DI pipe class K-9 upto 300 mm dia complete all as specified and as directed. 23 Item No 10 : Construction of mesonary valve pit chamber with burnt brick (Sub class B) in cement mortor (1:6) and 10 mm thick plastering in CM1:4 and PCC (1:4:8) type D-2 in foundation bed or size internally climent on 1500 mm x 1500 mm x 1500 mm with 3 mm thick MS sheet cover with locking arrangement hinged with 40 x 40 x 5 mm angle iron frame embeded in PCC (1:3:6) type C-1 etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces completed including earth work all as specified and directed. 24 Manning & Operation for 02 Years During Defect Liability Period: 25 Mate Fitter General Mechanic (FGM) (Semi-skilled) - 02 NO in each shift (total - 06 Nos FGM (Semi-skilled) 03 shifts) 26 Item No 11 : Manning & Operation for 1st year during DLP: Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrsincluding daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 27 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 0600 to 1400 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 28 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 29 Note for ser Item No 11 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 30 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 31 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 32 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 33 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 34 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 35 Item No 12 : Manning & Operation for 2nd year during DLP: Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 36 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 06 : 0600 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 37 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 38 Note for ser Item No 12 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 39 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 40 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 41 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 42 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 43 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 44 Item No 13 : Manning & Operation for 3rd year (To commence from next day of comletion DLP): Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 45 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 06 : 0600 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 46 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 47 Note for ser Item No 13 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 48 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 49 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 50 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 51 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 52 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 53 Item No 14 : Comprehensive maintenance, (To commence from next day Expiry of DLP) servicing and repairs of water treatment plant 600000 gallons alongwith cleaning of spray nozzles of aeration fountion, scrubbing of parshall flume so as to keep the flow surfaces clean of surface buildup or algae growth, deep cleaning the flash mixer by washing the attachment, dewatering the flocculator completely and cleaning its channels and removal of flocs deposit by any means, removal of sludge deposition in clarifier and depositing the sludge at a certain distance so as to avoid contamination to clear water, backwashing of rapid sand filters, cleaning of solution tanks for any deposition, ewatering the UG sump of capacity 2500 gallon and cleaning its interior surface for algae deposition if any, opening the valves and cleaning it and refixing in original state, cleaning of pipeline connetions and fixing the leakages if any all as directed by engineer- in - charge. 54 Item No 15 : Manning & Operation for 4th year (To commence from next day of comletion of item no.-13): Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 55 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 0600 Hours to 1400 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 56 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 57 Note for ser Item No 15 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 58 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 59 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 60 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 61 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 62 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 63 Item No 16 : Comprehensive maintenance, (To commence from next day of comletion of item no -14) servicing and repairs of water treatment plant 600000 gallons alongwith cleaning of spray nozzles of aeration fountion, scrubbing of parshall flume so as to keep the flow surfaces clean of surface buildup or algae growth, deep cleaning the flash mixer by washing the attachment, dewatering the flocculator completely and cleaning its channels and removal of flocs deposit by any means, removal of sludge deposition in clarifier and depositing the sludge at a certain distance so as to avoid contamination to clear water, backwashing of rapid sand filters, cleaning of solution tanks for any deposition, ewatering the UG sump of capacity 2500 gallon and cleaning its interior surface for algae deposition if any, opening the valves and cleaning it and refixing in original state, cleaning of pipeline connetions and fixing the leakages if any all as directed by engineer- in - charge. 64 Item No 17 : Manning & Operation for 5th year (To commence from next day of comletion of item no. 15): Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 65 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 0600 Hours to 1400 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 66 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 67 Note for ser Item No 17 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 68 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 69 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 70 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 71 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 72 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 73 Item No 18 : Comprehensive maintenance, servicing and repairs of water treatment plant 600000 gallons alongwith cleaning of spray nozzles of aeration fountion, scrubbing of parshall flume so as to keep the flow surfaces clean of surface buildup or algae growth, deep cleaning the flash mixer by washing the attachment, dewatering the flocculator completely and cleaning its channels and removal of flocs deposit by any means, removal of sludge deposition in clarifier and depositing the sludge at a certain distance so as to avoid contamination to clear water, backwashing of rapid sand filters, cleaning of solution tanks for any deposition, ewatering the UG sump of capacity 2500 gallon and cleaning its interior surface for algae deposition if any, opening the valves and cleaning it and refixing in original state, cleaning of pipeline connetions and fixing the leakages if any all as directed by engineer- in - charge. 74 Item No 19 : RCC hume pipe NP-2 1500 mm dia laid over 100 mm thick PCC type B-1, 1:2:4 over 100 mm thick PCC type E2 1:5:10, vertically. The top cover of valve pit chamber shall be covered with MS sheet 1.25 mm thick with MS Angle iron 40 x 40x 6 mm thick frame and MS angle iron 30 x 30 x 6 mm thick for shutter frame & flat iron 40 x 6 mm bracing with M.S. sheet. All MS item shall be painted with two coat o synthetic enamel paint over a coat of red oxide primer. 75 Item No 20 : MS pipe 40 mm dia (medium grade) @ 1.0 m spacing and 850 mm long) and MS pipe 25 mm dia (Medium grade) - 3 Row duly painted provided to coat of synthetic enamel paint over coat a red oxide primer, railing to be provided to every items/ Part of water treatment plant. 76 SCHEDULE A(Schedule of credit)Schedule of Credit Rs 994845.00 (Minus) inserted by the MES.(Note : Credit amount shall be deducted manually to arrive net bid amount)
Contract Date: Oct 31, 2025 Contract Value : 5.41 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
4.
Housing Urban and Rular Development #8047925 AOC
Maintenance And Repair To W/S/S At Vbia.. Repairs To Sub Div Office At Wtp -- 2Nd Call - Civil Works ( Referthe schedule B in Tender Document) 2 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. Ground Floor 3 First Floor 4 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 5 Providing internal cement plaster in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. Ground Floor 6 First Floor 7 Providing internal cement plaster in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.Ground Floor 8 First Floor 9 Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. Ground Floor 10 First Floor 11 Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.Ground Floor 12 First Floor 13 Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.Ground Floor 14 First Floor 15 Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m). Ground Floor 16 First Floor 17 Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Ground Floor 18 First Floor 19 Waterproofing Treatment to new Toilet/bathroom by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2- (methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of wall and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties:1) Elongation % (ASTM D412-2016): @ 100% 2) Tensile Strength N/mm2 (ASTM D412-2016): 3.3 3) Specific Gravity: 1.02 ± 0.02 4) Total Solids .Ground Floor 20 First Floor 21 Waterproofing Treatment to plastered surface of toilet & bathroom walls minimum up to 90 cm (Dado) by using 2- (methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Clean the entire surface thoroughly and over this prepared surface, apply three coats of 2- (methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge.While the 3 coat is wet broadcast sand on the surface. Provide 20 mm thick cement plaster in CM 1:3 with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement including all lead, lifts, curing etc complete. Acrylic Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties: 1. Elongation % (ASTM D412-2016): @ 100% 2. Tensile Strength N/mm2 (ASTM D412-2016): 3.3 3. Specific Gravity: 1.02 ± 0.02 4. Total Solids (ASTM D1644-2012): 43.98 5. Hardness Shore A (ASTM D2240-2015): 82 It shall be applied as per manufacturer’s specification. (All Rates are Excluding GST). Ground Floor 22 First Floor 23 Providing & fixing 35mm thk. door shutter finish with 1.0mm thk. Laminate on both sides as per approved pattern. All edges should finish with teak wood lipping with melamine polish. All complete as per instructions & approval of EIC. Note: The rate of all doors shall include all hardware such as door handles, hinges, door closures/floor spring, dead lock, PVC door buffer, door stopper, latches etc. as required. 24 Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box. Ground Floor 25 First Floor 26 Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.Ground Floor 27 First Floor 28 Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram / One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Ground Floor 29 First Floor 30 Name of Sub Estimate - Plumbing Works- Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means 31 Providing and fixing on walls / ceiling / floor 15mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground Floor 32 First Floor 33 Providing and fixing on walls / ceiling / floor 20mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor 34 First Floor 35 Providing and fixing on walls / ceiling / floor 25mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor 36 First Floor 37 Providing and fixing 15mm diameter water meter with non-return valve including strainer, sockets/ union nut including water meter box making locking arrangement and lock. [Without chamber]. 38 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 39 Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.Ground Floor 40 First Floor 41 Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. 42 Providing and fixing European type commode including flush tank, flush valve / plates outlet, inter connections through walls including all fittings etc. complete.As per direction of Engineer - in - Charge. 43 Providing and fixing 2 way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (Jaquar- FON-40041) 44 Providing and fixing 15mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete. Ground Floor 45 First Floor 46 C.P.Toilet paper holder of approved make and as per EIC. (Jaquar- AHS-1553) 47 Providing and fixing in position Double coat hooks as per instructions from EIC/Architect (Jaquar - ACN-1161N) 48 Providing and fixing Table top white wash basin of size approved by Architect / PMC which includes rubber plugs and brass chain, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to the outside face of the wall.etc complete as directed by Engineer in charge. (Jaquar - FNS-WHT-40601) 49 Providing and fixing Chromium Plated Alluminium Towel Rail 750 mm (26)long,20 mm (3/4)dia.and of approved quality fixed on chromium plared bracket including providing teak wood gutties in masonry etc complete as per direction of Engineer - in - charge (Rates excluding GST)) 50 Providing and fixing 15 mm dia Angle cock with guarantee against any manufacturing defect including socket, union nuts etc complete as per direction of Engineer - in - charge. 51 Providing & fixing of Pillar cock for wash basin inclusive of all its fixtures and pipes. Complete (Jaquar LYR-38021)( Rates excluding GST) 52 Providing and Fixing of Mirrors in Toilets of approved Indian quality, copper plated with 10 mm thick plywood backing in the masonry etc. complete.As per direction of Engineer - in - Charge. 53 Providing and fixing in position Soap Dispenser as per instructions from EIC/Architect (Jaquar- SDR-BLC-DJ0160AS) 54 Providing and fixing 15cm rigid PVC Nahani trap including PVC grating, bend, connecting piece of UPVC pipe upto the out side face of wall, making the good damaged surface and testing etc. complete (Prior approval of sample and brand by Ex. Engr. is necessary before use)Ground Floor 55 First Floor 56 Providing, laying and fixing P.V.C. pipe of 110mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Ground Floor 57 First Floor 58 Providing, laying and fixing P.V.C. pipe of 75mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Ground Floor 59 First Floor 60 c) 50 mm dia 61 Providing and fixing coloured glazed earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap brackets for fixing the cistern 32mm dia. P.V.C. flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection up to the outside face of the wall. 62 onstruction of BB masonry (230 mm thick in CM 1:6) sewer trap chamber or ordinary chamber with 20 mm. thick cement plaster in 1:3 CM cement concrete bedding M-75 grade concrete and CI grating, including RCC precast frame and cover etc. complete for depth upto 1.50 m (including cost of grating and excavation) 63 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete. 64 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 65 Providing and fixing in position Hand dyrer as per instructions from EIC/Architect (Jaquar- HDR-SAP-M99ACS) 66 Providing and fixing in position Urinal partition made up of 10mm thk frosted glass with chrome finish bracket for fixing of glass as per instructions from EIC/Architect (Jaquar- JSE-CHR-110UC450X) 67 Name of Sub Estimate -Painting Works-Providing & Applying Plaster of Paris Punning in average 12 to 25mm thickness to walls, ceiling, beams & columns to bring the surface in plumb Line & Level including making the surface smooth, providing required grooves on top of skirting etc. complete as per directions of Engineer - In - Charge. 68 Providing and applying colour-wash of approved colour and shade in two coats to new surface including scaffolding, brushing and brooming down (excluding base coat of white- wash) etc. complete.Ground Floor 69 First Floor 70 Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10 % and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying wall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush / rubber / spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9% with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.)Ground Floor 71 First Floor 72 Providing and applying plastic emulsion paint of approved quality, colour and shade to new surface in three coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. 73 Name of Sub Estimate -Electrical works-Point Wiring (WG-PW)-Point wiring for light/bell concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW 74 Secondary point wiring for additional light/bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification no. WG-PW/SW 75 Bunch of Wires (WG-MA/BW)-Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 76 Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW 77 Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW 78 Modular switches and Accessories-Supplying and erecting modular type switch 6A/10A on provided plate and box with wiring connections complete. 79 Supplying and erecting modular type switch 16/20 A with indicator on provided plate and box with wiring connections complete. 80 Supplying and erecting modular type 3 pin 6A multi socket with safety shutter on provided plate and box with wiring connections complete. 81 Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. 82 Supplying and erecting modular type blanking plate one module, on provided plate & box. 83 Concealing of Conduits (WG-MA/CC)-Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. 84 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.-1 or 2 Module (75 mmX75 mm) 85 3 Module (100 mmX75 mm) 86 4 Module (125 mmX75 mm) 87 6 Module (200 mmX75 mm) 88 8 Module (125 mmX125 mm) 89 10 Module (200 mmX150 mm) 90 Indoor LED Fittings (FG-IDF/LED)-Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 91 Supplying and erecting LED Panel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 92 Supplying and erecting LED Strip light Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs at L70B50 including driver with minimum 1 year warranty as per specification No. FG-IDF/LED. 93 Supplying LED concealed type foot / step light with aluminium body for indoor / outdoor application suitable for 4W - 6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with minimum 1 year warranty as per specification No. FG-IDF/LED. 94 Supplying and erecting LED Mirror Light with integrated driver including 7W to 9W lamp with polycarbonate housing and opal diffuser to be fixed above mirror or as required on clamps complete. 95 Supplying and erecting 1 light fancy wall bracket with arm fabricated from brass duly lacquered with suitable holder and fancy glass shade duly wired erected on wall with suitable size of polished wooden / laminated board.Supplying and erecting 1 light fancy wall bracket with arm fabricated from brass duly lacquered with suitable holder and fancy glass shade duly wired erected on wall with suitable size of polished wooden / laminated board. 96 Supplying & erecting LED 20W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete. (Rates excluding GST) 97 Fans (FG-FN)-Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF 98 Supplying and erecting Energy Saving Ceiling fan of 3 star rating as per BEE 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF 99 Accessories for Fans (FG-FAS)-Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. 100 Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. 101 Water Heaters (AP-WH)-Supplying and erecting storage type water heater 25 litres capacity having standing loss < 0.465kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function valve) complete with 3 core PVC flexible wire leads complete & total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete as per specification no. AP-WH/STWH 102 Supplying table lamp with M.S. tube with flexible joints complete suitable for lamp 1XPL- 5 / 7/ 9 W complete with lamp and 3 core round plastic flexible cord with 6A 3 pin hand shield type plug top. 103 LT - MCBDBs (SW-MCBDB)-Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways/24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB. 104 Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways/36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB 105 Supplying & erecting XLPE armoured cable 1100 V grade with ISI mark 106 LT Cables (Copper) (CB-LT/CU)-Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 107 Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 108 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 109 Name of sub Estimate -Demolition of Existing work-Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete 110 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish tincluding all lifts and lead. 111 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. 112 Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. 113 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. 114 Dismantling old sanitary fixures of all types i.e. W.C., urinals, wash basin etc. including its pipes and stacking of serviceable material and disposal of unserviceable material with all lead and lifts. 115 Removing old electrical fixtures of all types i.e. lights, fans, detectors, exhaust fan etc. including its wiring and stacking of serviceable material and disposal of unserviceable material with all lead and lifts. 116 Removing wooden or A.C. partition including frame work and stack-ing the materials as with all leads, lifts etc. complete. 117 Name of sub estimate -Architect Fees- Preparing interior layout, drawing, plans, detail drawing, colour combination sample chart preparation etc. All designing work required for the interior work including the preparation of electrical & Ventilation layout all complete. The amount computed & quoted @4.00% on the total quoted by contractor.
Contract Date: Oct 01, 2025 Contract Value : 36.25 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
TenderDetail
Loading tenders