View Bid Results For Non Conventional Sewage Tenders

We found 66 Bid Results related to non conventional sewage tenders. You can find Contractor details who won non conventional sewage tenders along with contract details in Bid awards announcements section.

Filters
Stage
58
7
1
Tender Publishing Platform
2
64
State / UT
18
19
7
6
5
4
4
3
3
2
2
2
2
2
1
1
1
1
1
Contract Value
8
4
27
27
Publish Date
0
0
0
0
0
Sector
9
40
15
3
2
2
1
1
1
1
Ownership
4
40
19
4
3
Within keyword
Active filters:
Showing 1–2 of 66 tenders matching your filters
1.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
2.
Defence #11110287 Technical Bid
Tender For Provision Of Md Accommodation For 16 X Officer At Ferozpur Mil Stn (Tender-1) (Tender Id : 2025_Mes_742975_2)- 3 Lump Sum Price Worked Out By The Contractor For Building Work As Listed In Schedule A Part-I Brought Forward From Serial Page No.30. 4 Lump Sum Price Worked Out By The Contractor For Site Clearance And Earth Works As Listed In Schedule A Part-Ii Brought Forward From Serial Page No.31. 5 Lump Sum Price Worked Out By The Contractor For Internal Electrification Works As Listed In Schedule A Part-Iii Brought Forward From Serial Page No. 32, 33(R) To 35(R). 6 Lump Sum Price Worked Out By The Contractor For Internal Water Supply Works As Listed In Schedule A Part-Iv Brought Forward From Serial Page No. 36(R). 7 Lump Sum Price Worked Out By The Contractor For Sewage Disposal Works As Listed In Schedule A Part-V Brought Forward From Serial Page No. 37. 8 Lump Sum Price Worked Out By The Contractor For Area Drainage Works As Listed In Schedule A Part-Vi Brought Forward From Serial Page No. 38. 9 Lump Sum Price Worked Out By The Contractor For Compound Wall Fencing And Gate Works Listed In Schedule A Part-Vii Brought Forward From Serial Page No. 39 & 40. 10 Lump Sum Price Worked Out By The Contractor For Road, Path & Culvert Works As Listed In Schedule A Part-Viii Brought Forward From Serial Page No. 41 & 42. 11 Lump Sum Price Worked Out By The Contractor For External Water Supply Works As Listed In Schedule A Part-Ix Brought Forward From Serial Page No. 43. 12 Lump Sum Price Worked Out By The Contractor For External Electrification Works As Listed In Schedule A Part-X Brought Forward From Serial Page No. 44 To 47. 13 Lump Sum Price Worked Out By The Contractor For Dg Set Work As Listed In Schedule A Part-Xi Brought Forward From Serial Page No. 48. 14 Lump Sum Price Worked Out By The Contractor For Lift Work As Listed In Schedule A Part-Xii Brought Forward From Serial Page No.49. 15 Lump Sum Price Worked Out By The Contractor For Fire Fighting, Fire Alarm & Detection System Work Works As Listed In Schedule A Part-Xiii Brought Forward From Serial Page No. 50 & 51. 16 Lump Sum Price Worked Out By The Contractor For Lightening Protection Work As Listed In Schedule A Part-Xiv Brought Forward From Serial Page No. 52. 17 Lump Sum Price Worked Out By The Contractor For Rain Water Harvesting Works As Listed In Schedule A Part-Xv Brought Forward From Serial Page No. 53 & 54(R). 18 Lump Sum Price Worked Out By The Contractor For Solar Water Heater Work As Listed In Schedule A Part-Xvi Brought Forward From Serial Page No. 55. 19 Misc Items Of Works (To Be Quoted By Bidder) As Listed In Schedule A Part-Xvii 20 Internal Water Supply Works 21 Supply & Fixing 15Mm Cp Brass Health Faucet (Hand Shower), Inlet Length 100Mm Fixed To Angle Valve With And Including Decorative Choice Flexible Pipe, Wall Hanger Etc Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. 22 Supply & Fixing 15Mm Bore Fancy Type Central Hole Single Lever Basin Mixer With 450 Mm Braided Connection Pipe Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed.Make Cera Model No F2013451 / Jaquarqqp‐Chr‐7167Bpm / Roca T5A8497Ca1 / Kohler Model No. K‐ 27484In‐4‐Cp 23 Supplying And Fixing Two Way Bib Cock With Single Handle And Wall Flange 15Mm Dia, Fancy Type Chromimum Plated Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. Make Cera Model No F2013163 / Jaquar Lyrchr‐38041 / Kohler Model No K‐16094In‐4‐Cp / Roca Model No.Rt5A937Aca1 24 Supply & Fix 15 Mm Bore Sink Mixer With Swinging Spout (Wall Mounted) With 150Mm Long Swivel Spout Connecting Legs & Wall Flanges Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. Make Cera Model No F2013501 / Jaquar Model No Ari‐Chr‐39165 / Kohler Model No. K‐20591In‐4‐Cp / Roca Model No. Rt5A8497Ca1 25 Supplying And Fixing Wall Mounted Bib Cock, Chromium Plated, With Wall Flange & Aerator (Cera Cat No. F1015151) / Jaquar‐ 16094In‐4‐Cp/ Roca Rt5A937Aca1 / Kohler Model No 16093In‐4‐Cp Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. 26 Supplying And Fixing 32 Mm Upvc Ball Valve With Screwed Both Ends Pipe And Fixed All As Specified And Directed 27 Internal Electrification Works 28 Material & Labour For Point Wiring With 1.5 Sqmm, Pvc Insulated But Unsheathed, Stranded Copper Conductor Single Core Frls Cable, Is-694 Marked, Drawn Through And Including Non Metallic Rigid Pvc Concealed Conduit Medium Grade 20Mm Dia (Minimum) Or Higher Size As Specified And Cutting Chasing On Wall Complete With All Pvc Conduit Accessories Such As Socket, Elbow, Junction Box, Bell Mouth, Reducer, Bend And Flexible Conduit Etc/ Fittings Isi Marked For Modular Fittings And Brass Screws And Cup Washers Including 1.5 Sqmm Stranded Copper Conductor Pvc Insulated Frls Cable Green In Colour As Continuous Earth Conductor Connected To Common Earth And Earth Dolly With All Accessories Complete All As Specified And Directed. Note:- Cost Of Metal Boxes And Modular Accessories Like Cover Plates Will Be Paid Seprately In Respect Items (A) Fan Point/ Exhaust Fan Point /One Light Point/Bell/Buzzer Controlled By One Switch/Bell Push. 29 (B) One Modular Socket Outlet 5 Pin 5 Amp Controlled By One, One Way Switch On Same Board. 30 (C) One Modular Socket Outet Point 5 Amps On The Independent Board. 31 (D) One Light Point Controlled By Two Nos Of Two Way Switch. 32 All As Ser Item 4.02 Here In Before But With 2.5 Sq Mm Wire And Earth Wire Of 2.5 Sq Mm For 3 Pin 15 Amp Modular Type Socket Outlet. 33 Supply And Fix Modular Metal Flush Box Made Out Of Gi Sheet, Thickness Not Less Than 1.2Mm With Earthing Terminal, 8 Module Complete All As Specified And Directed. 34 Supply And Fix Modular Metal Flush Box Made Out Of Gi Sheet, Thickness Not Less Than 1.2Mm With Earthing Terminal, 12 Module Complete All As Specified And Directed. 35 Supply And Fix Modular Dummy Plate Complete All As Specified And Directed. 36 Supply And Fix Led Energy Efficient Led Bulb B22, 9 Watt Complete All As Specified And Directed. 37 Supply And Fixing Vtpn Db’S 4 Way, Double Door, 415V, Ip43, Suitable Size And Length Of Crca Steel Sheet, Dust Protection Duly Powder Painted Including Factory Fitted Suitable Size Copper Bus Bar, 01 No Of Mccb Tpn As Incomer And 04 Nos Tp As Outgoing With Neutral Link, Earth Bar, Din Bar For Mounting Mcb And Blanking Plate A Complete All As Specified And Directed. Note:- Mcb Shall Be Measured And Paid For Separately. 38 Supply And Fixing Tv Socket And Connector Complete With All Necessary Fittings All As Specified And Directed. 39 Material & Labour For Wiring With 1100 Volt Grade One Single Core Frls Wire Pvc Insulated And Unsheathed Cable With Stranded Copper Conductor 1.5 Sqmm (For Inverter) Drawn Into Pvc Conduit With All Accessories Fixed Concealed Complete All As Specified And Directed. 40 Supply And Fix Led Tube Light Fitting In Extruded Aluminium Housing For All Purpose Surface And Wall Mounted With Single Side Connection Aluminium Led Batten With 125 Lum/Watt System Efficancy Polycarbonate Housing And Integrated Electronic Driver Of Capacity 20 W, Four Feet And Connection With Pvc Insulalted Twin Core 23/0.0076 Twisted Copper Cable From Ceiling Rose To Tube Light Fitting Complete All As Specified And Directed. Make: Havells Cat Part No. Enduralinearprobs20Wled865Spcssind Or Equivalent Make Of Bajaj/Crompton/ Philips. 41 Supply And Fix Wall/Ceiling Mounting Led 9/10 Watt Tube Light Fitting In Extruded Aluminium Housing And Integrated Electronic Driver Complete With All Acessories 1X9 Watt Led, With Cct Of 6000K Suitable For Domestic Application, 240 Volts, 50 Hz, And Internally Pre-Wired With 1.5 Sqmm Twin Twisted Flexible Cable Copper Conductor And Connection Complete All As Specified And Directed. Make: Havells Cat Part No. Lumilinebs9Wled865Spcwh Or Equivelent Make Of Bajaj/ Crompton/ Philips. 42 Supply And Fix Bldg Street Fitting Made Up Of Pressure Dai Cast Aluminum Housing With High Efficiency Leds As A Lighting Source And Lens Embedded Pc Cover Having Top Oppening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07, Cct 5700 K, Of Wattage 25 Watt Including Connection With 3 Core Pvc Insulated Overall Sheathed Flexible Cable With Multi Stranded Copper Conductor Of Size Not Less Than 1.0 Sq Mm From Celing Rose To Fitting Terminal All As Specified And As Directed. Make :- Havells/ Bajaj/ Hpl/Philips 43 Supply And Fix Gi Pipe Bracket Made Of Gi Pipe Light Grade 32Mm Dia And Bend To Shape 1.5 Mtr Long Ms Clamp Made Out Of Ms Flat Iron Of Size 32Mm X 3Mm With Nut And Bolts Washer Complete Including Drilling Of Holes For Nut And Bolts Etc Complete All As Specified And Directed. 44 Supply And Fixing Decorative Type Led Wall Lights Fitting 08/09 Watt, 220V, Suitable For Led Lamp B22 9 Watt Complete All As Specified And Directed. Make: Havells Cat No Lhfoecce1Tz1O014 Or Equivalent Philips/Cg 45 Supply And Fix Kitchan Wall Fan 300 Mm Sweep, 1350 Rpm, Of Elegantly Designed Fan Base In Round Shape For 50 Cub Mtr/Min Air Delivery And Minimal Noise Levels With Pull Code Control For Speed & Oscillation Upto 90 Degree Total Flexibility, Double Z Shielded Ball Bearing, Sturdy Brazed Wire Guards With Power Coating Ensures Corrosion Resistance Conforming To Is 2997-1964 Complete All As Specifed And Directed. 46 Supply And Fix Kitchan Chimney Dry Heat Auto Clean Technology Stainless With Air Outlet 150 Mm, Steel Finish Front Matte Black Glass Panel With Digtal Display Touch Control Panel With 3 Speed Gesture Motion, Heavy Duty Baffle Filters, Minimium Air Flow 1180 M3/H Energy Saving Led Light Of Suitable Wattage, Copper Winding Bldc Motor, 62Dba Max Noise Level And Voltage 220-240 V/50 Hz Including Making Hole In The Wall And Making Good The Distubed Surface Of Wall Including All Accessories All As Specified And Directed. Make : Kaff Model No.Sku Nevishc90 Or Eqvt In Hindware/ Faber. 47 Supply, Installation, Testing & Commissioning Of 3-Φ, 4 Wire, Ac Static Direct Connected, Smart Pre-Paid Energy Meters, Isi Marked Of Different Makes As Per Bis-16444, With Communication Technology Including Gprs/Rf/Hybrid (Rf Mesh Network+Gprs)/Any Other Advanced Technology As Per Cea/Trai Regulations) With Current Range 10-60 Amp, 415 V, Accuracy Class 1.0 Uc1 Category And Above Along With In-Built Load Control Switch, Containing Provision For Tod & Rtc, Capable To Define Multiple Tariff Slabs Complete All As Specified And Directed.Meter Should Support The Following Data:- (I) 15 Min Instantaneous Data For Voltage, Current, Power Factor, Power, Cumulative Energy And Frequency, Daily And Monthly Billing Survey For Cumulative Energy And Max Demand(Ii) Meter Should Have Connect / Disconnect Functionality Operable For Mdm/Billing Software And Prepaid Features Would Be Operable For Mdm / Billing End As Per Is: 15959 Part-2.(Iii) Meter Should Support Communication Protocol Through Rf/ 5G/4G/Nb Iot With The Existing Software In Stn All As Required At Site And Directed (Cost Of 5G/4G/Nb Iot Sim With Two Year Recharge Facilities, Mapping, Vending Portal Charges Etc Deemed To Included In Rate Quoted For Meter). (Iv) The Meter Should Support Open Communication Protocol Dlms With The Existing Software.Make: Anchor/L&T/Hpl/Secure.Note:- (I) The Smart Meter Would Be Compatiable With Existing Software/Dcu In Stn.(Ii) The Rate Of Sim As Well As Data Pack Of 24 Months From Date Of Completion For Connectivity Is Deemed To Be Including In The Quated Rates. 48 Supply & Fixing Of Transparent Polycarbonate Meter Box Of Suitable Size With Ip-54 For 3-Φ, 4 Wire, Smart Energy Meter Mentioned Here-In-Above At Sch. Item No. 4.21. The Polycarbonate Meter Box Shall Comply With Is-14772:2000 And Is-11000:1984. It Shall Be Totally Shock Proof, Safe Weater Proof, Rust Roof, Dust Proof, Water Proof, Halogen Free, Silica Free And Having Internally Embeded Gasket Technology, Transparent Hinged Lid And Sealing Provision Including Bakelite Connector, Complete All As Specified And Directed. Make: Anchor By Panasonic/L&T/ Hpl/Secure. 49 Road Works 50 Material And Labour For Preparing Bituminous Surface Of Road And Marking 2.5Mm Thick Hot Applied Thermo Plastic Road Marking Paint Of Approved Colour Providing Retroreflecting Glass Beads @ 250 Gm Per Square Metre As Per Irc-135 With Special Applicator Machine All As Per Manufacturers Instruction Complete All As Specified And Directed. 51 External Water Supply Works 52 Supply And Laying Ductile Iron Pipe Of 100Mm Bore With Spigot And Socket Ends Centrifugally Cement Mortar Lined Complete As Per Is 8329/ 2000 Class K-9 With Including Suitable For Tyton Joint And Jointing Material/ Joints Laid In Trenches Complete All As Specified And Directed.Note ;- Di Specials And Earth Work Shal Be Measured And Paid Seperately. 53 S&F 80Mm Dia Gi Tubing Heavy Grade C Class With All New Connections And Fitting Such As Tee, Elbows, Bend, Reducer, Unions, Short Pieces, Connector Back Nuts, Diminishing Pieces, Caps, Plugs Unions Etc Laid In Threnches Complete All As Specified And Directed. 54 Material & Labour For Valve Pits And Constructing Of Brick Masonary Pits Of Internal Dimensions 900Mm X 900Mm X 900Mm (Bottom Pcc Floor Of The Pit Should Be Minimum 30 Cms Below The Bottom Surface Of Sluice Valve Flange To Provide Sufficient Working Space), Bottom Floor Of The Pit Be Constructed In Pcc (1:3:6) 51 Cms Thick With 20 Mm Stone Aggregate, Inner And Exposed Surfaces And Bottom Floor Of The Pit Should Be Plastered In Cm (1:4) 15 Mm Thick. The Sluice Valve And Other Fittings Should Be Housed In Center Of The Pit. The Verticesof The Pit Should In Right Angle And Champhered. The Top Cover Of The Pit Will Be Made Out Of Ms Sheet Min 2 Mm Thick With Angle Iron Frame Made Out Of Ms Angle 50Mm X 50Mm X 6Mm With Galvanized Steel Hindges Two Nos And Locking Arrangements Duly Painted With Two Coats Of Water Resistant Synthetic Enamelled Paint Over One Coat Of Red Oxide Complete All As Specified And Directed. 55 Material And Labour For Taping From Existing Di 80 Mm To 150 Mm Including Cutting, Jointing, Inserting Tee And Alll Accessories Complete All As Specifed And Directed.Note:- Tee Shall Be Measured And Paid Separately Under Respective Items. 56 External Electrification Works 57 Supply, Install, Testing And Commissioning Of Lt Distribution Panel (Cpri Type Tested ) Cubicle Type Ip-65, Outdoor Type Confirming To Is-61439 Factory Fabricated Prewired Made Out Of 3.15 Mm Thick Crca Sheet Outer & 2 Mm Thick Crca Sheet Inner Of Suitable Size To Accommodate All Accessories/Fittings Compartmentalized In Construction To Accommodate The Incoming/Outgoing Mccb And Tpn Bus Bars And Outgoing Feeders. The Tpn Bus Bars Shall Be Insulted With Colour Coated Heat Shrinkable Sleeve And Shall Be Mounted On Dmc Support. The Incoming As Well As Outgoing Mccbs Shall Have Extension Links Of Current Carrying Cap Not Less Than 1.5 Times The Rated Capacity Of Individual Feeders. The Extension Links Shall Be Supported On Dmc Support Having Provision For Termination Of Incoming And Outgoing Cables. All Extension Links/ Interconnections Shall Be Colour Coated Sleeves. The Cubicle Shall Have Frame Work At Bottom Of Ms Channel Mc 100 Fixed To The Top Of Plateform. The Plateform Of Lt Panel Shall Be Pedestal Type Of Suitable Width And 600 Mm Height Above Ground Level And Minimum 400 Mm Below The Ground Level Constructed With Bricks (Sub ClassB) Work Duly Plastered In Cm 1:3 And Pcc Copping (1:2:4) Not Less Than 50 Mm Thick Over Brick Pedestal With Adequate Opening For Entry Of Cable Complete As Per Manufacture Recommendation And Directed By The Engr-In-Charge. A Detachable Gland Plate Of Thickness Not Less Than 3 Mm Thick Should Be Used At The Bottom For Entry Of Armoured Cable Of Adequate Size Compression Glands, The Panel Shall Be Painting With Powder Coated Finish With Ral 7032 Siemens Gray Structure After Seven Tank Phosphate Treatment Front & Back Opening Type And Fixing 2 Nos Danger Notice Plan With Letter Figures And Conventional Skull Bones In Signal Red Colour And Fixed Front & Back Door To Lt Panel With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Shall Have Louvers And Air Vent Gasket For Natural Flow Of Air Neoprene Adhesive Type Gasket Shall Be Used To Make Panel Vermin Proof And Comprising Of Following:- Please Enable Macros To View Boq Information 58 Supply, Install, Testing And Commissioning Of Lt Distribution Panel (Cpri Type Tested ) Cubicle Type Ip-65, Outdoor Type Confirming To Is-61439 Factory Fabricated Prewired Made Out Of 3.15 Mm Thick Crca Sheet Outer & 2 Mm Thick Crca Sheet Inner Of Suitable Size To Accommodate All Accessories/Fittings Compartmentalized In Construction To Accommodate The Incoming/Outgoing Mccb And Tpn Bus Bars And Outgoing Feeders. The Tpn Bus Bars Shall Be Insulted With Colour Coated Heat Shrinkable Sleeve And Shall Be Mounted On Dmc Support. The Incoming As Well As Outgoing Mccbs Shall Have Extension Links Of Current Carrying Cap Not Less Than 1.5 Times The Rated Capacity Of Individual Feeders. The Extension Links Shall Be Supported On Dmc Support Having Provision For Termination Of Incoming And Outgoing Cables. All Extension Links/ Interconnections Shall Be Colour Coated Sleeves. The Cubicle Shall Have Frame Work At Bottom Of Ms Channel Mc 100 Fixed To The Top Of Plateform. The Plateform Of Lt Panel Shall Be Pedestal Type Of Suitable Width And 600 Mm Height Above Ground Level And Minimum 400 Mm Below The Ground Level Constructed With Bricks (Sub ClassB) Work Duly Plastered In Cm 1:3 And Pcc Copping (1:2:4) Not Less Than 50 Mm Thick Over Brick Pedestal With Adequate Opening For Entry Of Cable Complete As Per Manufacture Recommendation And Directed By The Engr-In-Charge. A Detachable Gland Plate Of Thickness Not Less Than 3 Mm Thick Should Be Used At The Bottom For Entry Of Armoured Cable Of Adequate Size Compression Glands, The Panel Shall Be Painting With Powder Coated Finish With Ral 7032 Siemens Gray Structure After Seven Tank Phosphate Treatment Front & Back Opening Type And Fixing 2 Nos Danger Notice Plan With Letter Figures And Conventional Skull Bones In Signal Red Colour And Fixed Front & Back Door To Lt Panel With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Shall Have Louvers And Air Vent Gasket For Natural Flow Of Air Neoprene Adhesive Type Gasket Shall Be Used To Make Panel Vermin Proof And Comprising Of Following:- Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
3.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
5.
Defence #9895073 AOC
Tender For Provision Of Offers And Jcos Accommodation At Kiari Mil Stn Under Ge 860 Ews; 1 NOTE: Schedule ‘A’ Part - ItoPart -Xare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 2 Total amount of Sch A Part - I(BUILDING Works) 3 Total amount of Sch A Part - II (SITE CLEARANCE WORKS) 4 Total amount of Sch ‘A’ Part - III (INTERNAL WATER SUPPLY) 5 Total amount of Sch ‘A’ Part - IV (INTERNAL ELECTRIC SUPPLY)) 6 Total amount of Sch ‘A’ Part - V (PROTECTIVEWORKS) 7 Total amount of Sch ‘A’ Part - VI (HARDSTANDING WORKS) 8 Total amount of Sch ‘A’ Part - VII (SEWAGE DISPOSAL) 9 Total amount of Sch A Part - VIII(EXTERNALELECTRIC SUPPLY WORKS) 10 Total amount of Sch ‘A’ Part -IX ( EXTRNAL WATER SUPPLY WORKS) 11 Total amount of Sch ‘A’ Part - X (HOT WATER SUPPLY) 12 SCH A PART - XI(Miscellaneous B/R and E/M works for Sch A Part-II to Part-X)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 13 Supply and fixing ofLED building security light, pressure die cast aluminum housing, 20/25 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 14 Supply and fixing of Double door three phase prewired distribution board vertical DB VTPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately) 15 Supply and fixing of LED Garden Light 9 W 220 V,single phase,IP-65 with post top fitting,powder coated aluminium die cast and spun aluminium with clear/opal diffuser suitable for landscape lighting complete all as specified and as directed by the Engineer-in-Charge. 16 RCC Septic tank for 25 users conventional designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.2 meter and overall depth of 1.95 meter complete all as specified and shown on drawing (Ref Drg No CELZ/D/ST-3009, Sh No 1/4 to 4/4 17 Soakage wells of size 3M dia x 4.5 M effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and directed. 18 Supply, installation, connecting, testingand commissioning of cubicle compartmentalised outdoortype LT Panel size 1.8m x 1.5m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Plateform, connected with electric supply complete all as specified and directed by Engr -in-Charge 19 (a)Bus bar chamber having 4 Aluminium strip Bus bar having air insulated and PVC sheathed 200 A Capacity fixed in position with required nuts bolts and porceline insulator etc.(b)MCCB 4 Pole, 16 KA, 415 V, with adjusstable Thermal and fixed Magnetic (Manual Fixed type) of capacity 125 Amps. ( Incoming )(c)MCCB 3 Pole, 16 KA, 415 V, with adjusstable Thermal and fixed Magnetic (Manual Fixed type) of capacity 63 Amps x 4 nos. (02 x Nos Outgoing and one feede pillar,01 spare)(d) ON Load Change over Switch 125 Amps 4 Pole adjustable type -01 No(e)Volt meter 0-500 Volt meter digital type with selector switch.(f) Amp meter 0-200 Amp digital type with suitable CT and PT with selector Switch. (g)Phase indicator lamp LED Type -1 setNote : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform including necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. 20 Supply, install, connecting, testingand commissioning of cubicle compartmentalised outdoortype LT feeder pillar box size 0.6m x 0.45m x 0.3m, factory made, front and rear opening with locking arrangement, dust and vermin proof, CPRI approved, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Platform, connect with electric supply complete all as specified and directed by Engr -in-Charge 21 (a)Bus bar chamber having 4 Aluminium strip Bus bar having air insulated and PVC sheathed 100 A Capacity fixed in position with required nuts bolts and porceline insulator etc.(b) MCB TPN 40 Amp, 16 KA, 415 V). ( Incoming )-01 No(c) MCB TPN 40 Amp, 16 KA, 415 V). ( Outgoing )-01 No(d) MCB SPN 25 Amp(Outgoing)-01 No(e)Phase indicator lamp LED Type -1 setNote : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform including necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. 22 Supply, installation, testing & commissioning of Outdoor (IP54) 11kV 630Amps 21KA/3 sec. Non- Extensible 3 Way Ring Main Unit Compact switchgear consisting of1 nos. fixed manual Vacuum Circuit Breaker Moduleand 2 nos. fixed manual Load break switch module and Copper Busbar in SF6 insulated stainless steel enclosure (2.5 mm thick, SS304 grade). The complete RMU must be type tested for Internal arc 21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber. The offered RMU must be suitable for working at an altitude of 3700 meter & temparature upto -25 Degree Centegrade. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. The Vaccum Interrupter must RMU manufacturers own make. Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE [ Channel partner / System Integrator / Authourized Partner/ License partner make RMU shall not be accepted. The complete RMU shall be consisting of followings: 23 (a) Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint) for each VCB Module.(b) Capacitive voltage indication fixed type system with LED for all the module(c) SF6 Gas pressure indicator on the gas tank.(d) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO .(e) CT shall be minimum 80-40/1A ,2.5VA , 5P20 - 3 nos. for protection(f) Touch proof cable termination kit to be provided in each module 24 Supply, install, connecting, testingand commissioning of cubicle compartmentalised outdoortype LT Panel size 1.8m x 1.5m x 0.7m, factory made, front and rear opening with locking arrangement, dust and vermin proof, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, labeling, etc. and section pillar box shall comprising the following complete including fixed in position with PCC foundation 1:4:8 Platform, connect with electric supply complete all as specified and directed by Engr -in-Charge 25 (a)Bus bar chamber having 4 Aluminium strip Bus bar having air insulated and PVC sheathed 600 A Capacity fixed in position with required nuts bolts and porceline insulator etc.(b)MCCB 4 Pole, 36 KA, 415 V, withmicroprocessor(Manual Fixed type) of capacity 400 Amps. ( Incoming )(c)MCCB 3 Pole, 16 KA, 415 V, with adjusstable Thermal and fixed Magnetic (Manual Fixed type) of capacity 100 Amps x 2 nos. (02 x Nos Outgoing)(d)MCCB 4 Pole, 125 A,16 KA, 415 V, with adjusstable Thermal and fixed Magnetic (Manual Fixed type) of capacity Outging for offr living accn )(e)Volt meter 0-500 Volt meter digital type with selector switch.(f) Amp meter 0-200 Amp digital type with suitable CT and PT with selector Switch. (g)Phase indicator lamp LED Type -1 setNote : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform including necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. 26 Supply and fixing nitryle rubber insulation for tubing of size suitable for any pipe size & 32mm-50 mm thick outer dia, conductivity suitable for temperature range of (-)40ºC to (+)40ºC and class-0 fire resistance, water vapour permeability > 7000 and CFC free complete all as specified and directed. Note:-Area will be calculated based on outer dia. 27 Providing and fixing of aluminium cladding of 0.32 mm thick Aluminium Sheet on insulated pipes 32 mm dia (for exposed pipes only) but, 40 mm dia pipe (for exposed pipes only) complete all as specified and directed. 28 Material and Labour for providing tracer/antifreezing cable of range between 20 Watt/meter required to keep the pipe warm upto avoiding freezing of all as specified including electrical wiring cable for connection of suitable size complete all as specified and directed. 29 Supply and fixing Connection panel cum temperature controller to regulate electric supply to the Heat Tracer Cable 65W to maintain temparature to the water supply pipe line laid underground and to the exposed pipe line and connecting to the LT Supply complete all as specified and directed. 30 Supply and Fixing Submersible pump set suitable for 230 V , single phase system having capacity 1.0 HP.including making header complete all as specified and directed by Engineer-in-charge. ( 1 For stand by). 31 Supply and fixing submersible copper conductor cable 3 core, 2.5 sqmm 1100 volt flat industrial grade including nylon binding wire and accesories to clamp with column pipe at two places to each column pipe complete all as specified and directed. 32 Supply and fixing ofDOL starter 230 V single phase suitable for submersible pump set of capacity 1 HP all as specified and as directed by Engineer-In-Charge 33 Supply and fixing insulation tubing of size suitable for 20mm dia pipe and 13mm thick conductivity of nitrile rubber tubes class 0 with 0.32mm thick plain aluminium steel alloy 31000 H4 in ridges, hips, valley gutter drip and straight flashing of 28SWG thickness complete all as specified and directed. 34 Supply and fixing insulation tubing of size suitable for 25mm dia pipe and 13mm thick conductivity of nitrile rubber tubes class 0 with 0.32mm thick plain aluminium steel alloy 31000 H4 in ridges, hips, valley gutter drip and straight flashing of 28SWG complete all as specified and directed.
Contract Date: Mar 27, 2026 Contract Value : 7.93 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
6.
Defence #9749550 AOC
Tender For Provision Of Deficient Married Accommodation At Air Force Station Phalodi Boq (11 Aug 2025).; 1 NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. 2 Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch A Part I. 3 Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch A Part II 4 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch A Part III 5 Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch A Part IV 6 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch A Part V 7 Lump sum price worked out for AREA DRAINAGE as listed in Sch A Part VI 8 Lump sum price worked out for ROAD/ PATH as listed in Sch A Part VII 9 Lump sum price worked out for FENCING/GATE as listed in Sch A Part VIII 10 Lump sum price worked out for EXTERNAL ELECTRIFICATION/STP as listed in Sch A Part IX 11 Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch A Part X 12 Lump sum price worked out forRAIN WATER HARVESTING as listed in Sch A Part XI 13 Lump sum price worked out for HOT WATER SUPPLY as listed in Sch A Part XII 14 SCHEDULE A PART - XIII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. 15 SITE CLERANCE & DEVELOPMENT 16 M & L for Surface excavation n.exc30 cm deep and averaging 20cm deep and getting out top layer arqanie soil without disturbing or destroy its texture and remove the same to a location specified and stored properly for relaying after the completion of building work exc 50m but n exc 250m complete all as specified and as directed 17 Relaying the soil excavated in Item no 13 to building site for landscaping and gardening complete all as specified and directed 18 S&F colour coaded plastic dustbins of 120 Litre capacity each in Green/Blue/Red in colour as directed by GE , made of high grade UV resistant polyethylene, suitable for segregation of biodegradable, recyclable, hazardous and sanitary waste bins to be durable , Light weight, weatherproof, easy to clean with tight fitting lids and clear identification lables complete all as specified and directed..Note :-Labelling on dustbin are as follows:a) Green color waste bin :- Bio degradable wasteb) Blue color waste bin :- Reusable/ Recycle waste c)Red color waste bin :- Land Fill waste 19 INTERNAL ELECTRIFICATION 20 S & F for wall mounted LED box type tube light fitting 4 x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 21 S & F forLED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 22 S & F forLED tube light fitting with aluminium housing 2 feet x 5 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 23 S & F for Decorative wall mounted luminaire made out of Nickle finesh square base with bend pipewith unbreakable globe glass suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed. 24 S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC)with remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed. 25 S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 26 S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existingwall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 27 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (12) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as specified and directed 28 INCOMING(a) Copper strip busbar of suiable of capacity 200 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 12 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 13 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 29 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (07) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as directed 30 INCOMING(a) Copper strip busbar of suiable of capacity 120 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 06 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 07 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 31 M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 32 Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 33 Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on displayThe meter should support open communication protocol DLMSwith the softwareNote :-(a) It should run the meter in both prepaid and postpaid mode(b) The meters should carry 5 year warranty.(c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters 34 Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software forwith following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency.b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events(ii) Communication module: The system should provide communication of energy data and bills via print, email.(iii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process.(iv) Excel Export : The system would support export of metering and billing data in excel formatNote:- (i). Software will be compatible with all makes of smart meter & shall be CERT-IN certified from CERT approved vendors for any cyber security related threat & complying as per ENC guidelines.(ii) It shall also include recurring SMS charges, Email gateway integration charges, payment gateway charges for online meter recharge etc & shall be included in quoted rate for 2 years DLP period.(iii) Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the competion of defect liability period of 2 years.(iv) The software would be hosted on MEITY GCC approved server. 2 years hosting costs would be included. 35 INTERNAL WATER SUPPLY 36 S & Fchromium plated fancy type Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 37 S & FChromium plated fancy type two way Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 38 S & FChromium plated fancy type Bib cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 39 S & FChromium plated fancy type Pillar cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 40 S & FChromium plated fancy type Sink cock(wall mounted) with Aerator long shunk quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 41 S & F Chromium plated fancy type Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete all as specified and directed.Make - Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 42 SEWAGE DISPOSAL 43 Supply, laying and testing of 150mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 44 Supply, laying and testing of 200mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 45 SEWAGE TREATMENT PLANT(STP) 46 Supplying, Design , Construction, Hydraulic testing , Commissioning and giving satisfactory trialsSTP of capacity 10KLD consisting of PMF Technology based along with the following accessories to the desired capacity of 10 KLD rated net outputcomplete as turnkey jobwith all involved electrical and mechanical componentsfor satisfactory performance of plant andrequired treated outlet waterparameters as per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023 complete all as specified and directed(a) Construction RCC tanks of following sizes:-(i) Septic tank of size - 3.70 Mtr x 1.80 Mtr x 1.50 Mtr - 01 No(ii) PMF tank of size - 4.20 Mtr x 2.80 Mtr X 1.20 Mtr- 01 No(iii) Filter Feed tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(iv)Treated Water tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(v)Chamber between PMF & FFT of size- 0.45 Mtr x 0.45 Mtr x 0.45 Mtr - 01 No(vi) Manhole Chanber made out of brick work im CM 1:6 suitable size with FRP Manhole Covers of size - (600 mm x 600 mm) - 05 Nos 47 (b) Supply & laying of Stone course aggregate of following sizes:-(i) 8 size (200 mm) - 2.60 Cu mtr(ii)4 size (100 mm)- 2.60 Cu mtr(iii)2 size (50 mm) -2.60 Cu mtr(iv)Coarse Sand - 2.60 Cu mtr(c) Supply & laying of Bacterial Culture ( suitable for degrading sewage-1200.00 KG(d) Supply & plantingof saplings Canna Indica - 60 Nos(e) S & F for Non-clog submersible Raw sewege Pump, Single phase, 230 Volts, 50 Hz of discharge capacity 0.63 cum/ Hr @ 10 Mtr head complete- 02 Nos (01 W+ 01 S) (f) S & F for Submersible opern well pump set, Single phase, 230 Volts, 50 Hz for fresh treated water application discharge capacity 0.63 cum/ Hr@ 25 mtr head complete- 02 Nos (01 W+ 01 S) (g) Supply and install for heavy duty chemical dosing system plunger type suitable to injet solution with suitable capacity, working pressure10 Kg/cm2, comprising dosing pump coupled with 3 phase electric motor of suitable capacity, 1440 rpm assembly with Agitator in one motor , Agitator with stainless steel sweepblade duly FRP coated, FRP tank suitable capacity, complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint complete with chemical grade PVC NRV along with control panel for dosing pump suitable made of power coated MS fabricated box consting of LED indicater, digital Voltmeter, single phase preventor, high voltage, low voltage protection complete - 01 Job 48 (h) S & F for of PSF (Pressure sand filter) of size 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with multi port valve and interlinking piping - 1 Job(j) S & F for for ACF (Activated Carbon Filter) ofsize 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with with multi port valve and interlinking piping - 01 Job(k) S & F for UPVC Pipe of sizes 25 mm dia & 40 mm dia suitable with stand the pressure 6 kg/cm2 as required- 01 Job(l) S & F for copper conductor multistranded 3 core cable PVC insulated sheathed calble of size 2.5 Sqmm for motor connections from starter panel to motor control connector as required- 01 JobNote:-Components/ units/ Equipment/ accessory for PMF Technology based STP is as perdesign and indicative . However OEM can add/ alter/ omit the given components as per their design to achieve desired capacity and treated outlet water parameter with same technology as per E - in- Cs Branch New Dehli guidelines/ policies . 49 Supplying, Design, Construction, Hydraulic testing , Commissioning and giving satisfactory trials for Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP along with the following accessories to the desired capacity of 30 KLD rated net output, complete as turnkey job with all involved electrical and mechanical components complete all as specified and directed for satisfactory performance of plant and required treated outlet water parametersas per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023Note:- The STP shall be designed based on the inlet & outlet parameters of E-in-Cs Branch above policy.(a)Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP inclusive of Solid Separation, Anoxic Zone, MBBR Aeration Zone & Final Sedimentation zone Tank of size 8440 mm (L) x 2430 mm (dia) Tank- 01 No(b)Chop Whoop Winding Process based FRP Underground Intermediate Water Storage Tank 10 KL of size 4310 mm (L) X 1830 mm (dia) Tank- 02 Nos(c) With socket provision on tanks as per the design of UPVC return sludge pipe 50mm dia, PVC inlet outlet pipe 150mm dia, PVC interconnection pipe of 150mm dia, UPVC 80 mm dia, FRP Straps, Turn Buckle Wire Rope, Concrete Deadman & Eye Bolts per the diameter & length of the tank, Manhole cover as per the drawing, PVC air vent nozzle of dia 50mm, manhole cover of size 550mm dia, etc- 01 Job.(d) S & F for On-Ground LLDPE Treated Water Storage Tank of 10 KL Capacity of size2550 mm dia x 2510 Height- 01 No(e)Supply installation, testing and commissioning of cubical type Relay Based Control Panel out door type madeout of 3.15 mm thick CRCA sheetof suitable size suitable for 415V, 3 Phase, 4 wire, 50 Hz AC with necessary MCCB for incoming , copper busbar, MCB for out going & necessary DOL stater etc- 01 Job 50 (f)Twin lobe rotary Air compressor capable of delivery 56 Cum /Hr suitable volume of free air at 0.27 - 0.37 kg/sq.cm, discharge Pressure 0.2 - 0.3 kg/cm2g, Noise Level at 1.5 m distance: <70-80 (DBA),Body rotter made out of EN19 with FG260 & FG-260(CI), Silencer Fabricated with MS material.driven through V belt or directly coupled though flexible coupling to a TEFC motor of suitable capacity 1440 RPM, 415 Volts, 3 Phase,50 Hz, Pressure guages-01 No,150 mm NRV -01 No, Butterfly shut off valve, air filter, cleaner etc including 3 core copper cable multistranded connection of suitable size from starter to air compressor assembly complete all as specified and directed. 02 Nos (1W + 1S)(i)UPVC pipes 80 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specified- 01 Job(g) Sludge Recycling Pumpof non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set suitable with Flow Rate 9.0 m3/hr, Head 10 Mtr (1.0 HP) for operation at 415Volts frequency 50Hz, 3 Phase- 01 No (1W) (For Sludge recycling in Solid Separation zone)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangements complete all as specified- 01 Job(h) Pressure Sand Filter Capacity 3.0 cum/hr made out ofFRPSide Mounted of Size: 21 x 62,workingPressure 10 PSI, Filter Media, Pebbles & Filtering Sand, PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job 51 (j)Activated Carbon Filter Capacity: 3.0 cum/hr, made out ofFRPSide Mounted of Size: 21 x 62, workingPressure 10 PSI, Filter Media: Activated Carbon 900 - 1100I/V,PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job(k)Chlorine (Sodium Hypochlorite) Dosing Pump of Capacity 0-6 LPH, PTFE Diaphragm, single phase 230 Volts, 50 Hz including with HDPE Chlorine Dosing Drum of Capacity 100 Ltrs and necessary connections etc- 01 Job(l) Filter feed pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 3.0 m3/hr, Head 15-20Mtr (1.0 HP), suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping into PSF & ACF Filters)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii) UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangementscomplete all as specified- 01 Job(m)Raw sewage Water transfer Pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping from Raw Sewage Collection tank into the Bar Screen Chamber)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor (k) Ctype shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job 52 (n) Treated Water transfer Pump of Monoblock pump set suitable to handle domestic treated water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase (1W+1S) (For pumping from treated water zone to reuse)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job(o) Fine bar Screen with chamber (manual) of SS 304 for screening 5 to 6 mm particles of size 1.0 Mtr x 1.0 Mtr at inlet of MBBR tank- 01 Job 53 Note : - (i)The Package STP tank shall be made from 100% FRP Material through Chop Whoop Winding Process with compliance and certification/approval in UL 1316 from the UL LLC that is Underwriters Laboratories LLC.(ii)The FRP tanks shall be made using Isopthalic Unsaturated Polyester Resin.(iii) The Sewage Treatment Plant system shall have a valid certificate of a Green product from a reputed Government or Third party having authority to certify like CII, IGBC, Assocham or any other body having competence in issuing such certificates.(iv)The shell thickness of the tank shall be between 6.50 mm to 7.50 mm (±0.5 mm) & Dish end thickness must be 11 mm and above made only from 100% FRP material(v)Technology must be empanelled in CPHEEO Sewage Manual.(vi)Minimum Hydraulic Retention time of the total Package STP system/tank must be 22.00 hours.(vii)Minimum sludge handling should only be once a year(viii)STP must function from minimum load of 5 - 10% to 100%. (Minimum load to Peak Load)(ix)The STP must have an anoxic zone for denitrifuication(x)Minimum volume of Intermediate Water Storage tank in FRP MOC must be 10 KL(xi)Minimum volume of Treated Water Storage tank in LLDPE MOC must be 10 KL 54 Material and Labour for Motor ControlLT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete including the following accessories:-. 55 IN COMING:-(i)Copper strip busbar of 60 Amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(ii) On load change over Switch TPN of capacity 32Amps - 01 No (iii) 4 Pole MCB of capacity 5-32 Amps 10 KA breaking capacity C curve-01 No(iv)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) (v)Digital Multifunctional meter , flush mounting type with CT’sand selector switch – 01 set.OUT GOING :-(b) MCB SPN 5-32 Amps 10 KA breaking capacity C curve-04 Nos(c) DOL starter single phase with suitable relay range conforming to IS -1347(Part IV) suitable for discharge capacity 6.4 LPM ( 0.38 Cumt/Hr)at 10/25 Mtr head, 0.50 HP, including overload relay, auto timer, indicating lamps (LED) etc complete -04 Nos 56 Supply and laying fordouble wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of size nominal outer dia 63 mm & nominal inner dia 50 mm dia with all fittings laid in trenches / road/ nallah or fixed along wall for cable protection all as specified. 57 HOT WATER SUPPLY 58 Supply and installation,commissioning and testing at roof top of building Solar water heating system (Flate Plate Collector) based on indirect transfer of heat of capacity 100Ltr per day with electrical back up of 2 KWas per manufacturers recommednations includinghot water storage tank of capacity 300 ltrs and of 20 guage thickness stainless steel plate (having insulation of rock wool ) mineral wool 100 mm thick & cladding with aluminium sheet 24 SWG complete all as specified and directed. 59 ROAD/ PATH 60 Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed. 61 EXTERNAL ELECTRIFICATION 62 Supply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER/ 11 KV CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed. 63 S upply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with DANGER/ LT 433 VOLTS CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and as directed. 64 Supply, installation, Testing and commissioning of Outdoor type (IP 54), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 21kA-3 Sec,IP54 SF6 insulated, One side Extensible,consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Twor Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M), inside robotically welded stainless steel 304 (Non Ferrite non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The complete RMU must be type tested for Internal arc21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must RMU manufacturers own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protectioncomplete all as specified and as directed. The unit shall include the following with all necessary standard fitting as required at site.-Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.) 65 (a) Vacuum Circuit Breaker consist of following accessories :-(i)Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator on the gas tank.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation.(v)CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi)CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering(vii)Right angle boot to be provided in each module(viii)2 x12 Volts, 26 AH Battary with Charger - 1 Set(ix)Bus VT shall be 11KV/V3/110V/V3 ,20VA , Class 0.5 - 3 Nos. for metering(x)Auxiliary VT shall be 11KV/230 ,500VA for AC supply input to Battary Charger.(xi)Capacitive voltage indication fixed type system as per IE(xii)Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm,11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. 66 (xiii)Right angle boots (push on type)(xiv)Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB.(xv)Necessay interclocking arrangement for safety and operations(xvi)One No. Operationg Handle for Manual Operation and one no. manometer(xvii)Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions.(xviii)Above switchgear shall confirm to all relevant IEC/IS Standards. 67 Supply, installation, commissioning and testing of transformer of capacity 315 KVA, confirming to IS 1180 (Part-1)- 2014 with latest amendment No 4, BEE 3 star rated, EEL 3, step down Outdoor type complete with standard fittings, HT 11 KV 3 phase LT 433 vols, 3 phase, 4 wire corrugated 7 position off circuit tape links of rating + 7.5 to -7.5% @ 2.5% by means of hand operated off load tap changer including necessary control wiringtransformer copper wound, double wound, oil immersed naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn -11 (vector group with neutral brought on secondary side (LV side) and the maximum temperature rises should not exceed 40 degree centigrade in oil and 45 degree centigrade in HV/LV winding ring measured by resistance after continuous full load run in ambient temp as per IS -2026 per transformer, IS-3639 for fitting & accessories, IS-2099 for high voltage porcelain bushings and the transformer shall be comprised with the following standard fitting with on load tappings on HT side to vary secondary voltage within limit all as per IS -1180 complete all as specified and as directed wit latest policy for following:- 68 Note 01:- (i)Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers with cable end box.(ii)Four Nos porcelain bushing suitable for 433V on LV side, complete with copper rods, nuts and washers with cable end box.(iii)Monogram plate.(iv)Oil conservator with filter and drain plug.(v)Prismatic/transparent oil gauge.(vi)De-hydrating breather with first fill of dehydrating agent (silica gel).(vii)Thermometer pocket.(viii)Air release plug.(ix) Inspection cover(x) Lifting lugs for complete transformer(xi)Top cover lifting lugs(xii) Jacking lugs(xiii) Top filter valve(xiv)Instruction plate(xv)Drain cum bottom filter valves(xvi)Earthing terminal and stud(xvii)Off load tap changer (xviii)Rating and Diagram plate(xix) Buchholz relay with alarm & trip contacts.(xx)Bi directional roller wheel -04 Nos. 69 (xxi)Marshalling box for termination of all alarm & trip controls of the transformer.(xxii)WTI (Winding temperature indicator) with alarm & trip contact(xxiii)Oil surge relay.(xxiv)Shut off valve for buchholz relay.(xxv) OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type.(xxvi)Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body.(xxvii) Necessary PCC foundation/ block masonry platform as directed by OEM. (xxviii)First filling of new and unused transformer oil, IS-335 marked.Note 02 :- (a)The rates include for supplying transformers with standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, testing and commissioning. (b) The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in supplied and installed rates, cost of PCC foundation shall be included as per manufacturer drawing) 70 Supply, fixing, installing and commissioning of octagonal Galvanised street light pole 9 mtr long, top dia 70 mm, bottom dia 155 mm, sheet thickness 3 mm and base plate dimensions 260 x 260 x16 mm thickness with door locking arrangement for provision ofterminal plate consisting ofMCB TPN 10 Amps, with necessary electrical connections including 04 Nos foundation with J type foundation bolts -04 Nos of sizeas per manufacturer design should be hot dipped galvanized andGI single arm bracket (Ornamental type) complete with door locking arrangement complete all as specified and directed.Note:- Necessary Excavation of Soil, RCC foundation as per manufacture recommendation including foundation bolts etc deemed to be included in quoted rate. 71 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Transformer main LT Panel) 72 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:a)Copper strip busbar of 1000 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 500 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 73 OUTGOING:- (a)4 Pole MCCB 125 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (MWO/ WO accn Bldg Panel No 1)(b)4 Pole MCCB 160 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (for Sgt Accn Panel No 2, 3, APFC panel & Spare)(c)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No(d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 74 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (forMWO/WO Accn LT Bldg Panel No1)Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 75 IN COMING:-a)Copper strip busbar of 250 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 125 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 76 OUTGOING:- (a)4 Pole MCCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos (forMWO accn Bldg supply- 2 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No (Street light)(c) Multifunctional Digial type Astronomical function Time switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No(d) Power contractor 4 Pole, 32 Amps,415 Volts, 50 Hz - 01 No (e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 77 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-(for Sgt accn Bldg Panel No 2 & 3) 78 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:- a)Copper strip busbar of 400 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 79 OUTGOING:- (a)4 Pole MCCB 100 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos ( Sgt Accn bldg supply- 02 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No(e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 80 Material and labourfor Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for cable protection and making good as existing complete all as specified and as directed. 81 Material and labourfor maintenance free Chemical earthing of technology 3 mtr long20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 82 Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 1.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 83 EXTERNAL WATER SUPPLY 84 Supply, Laying, jointing & testing of 150mm dia (6) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed 85 Supply, Laying, jointing & testing of 100mm dia (4) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed.Notes foraboveItems No 53 & 54 :- (i) Excavation & Earthwork, shall be measured and paid separately. (ii) The necessary Exise duty exemption certificate from Deputy Commissioner of respective district shall be arranged by the GE for DI pipe.The contractor shall quote the rates against these items considering Exise exemption. (iii) The quoted rate shall also be deemed to include for provision of joints and jointing material for laying pipes. For jointing ofpipe fittings or taking branch connection, provision of joints and jointing material shall be measured and paid separately. (iv) . Before laying of pipe line contractor has to submit layout diagram as per level difference and ensure proper alignment of the pipe. 86 Material and Labour for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. Y junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 250 mm dia bore including cutting and jointing new positions complete all as specified and as directed 87 Material and Labour forcutting CI pipes 150 / 80mm in position for insertion and including provision of Tee branches etcfor 80/50 mm dia pipe line complete all as specified and directed 88 Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 89 Material and labour for construction of brick masonry valve pit of internal size 60cm x 60cm x 70cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 90 RAIN WATER HARVESTING 91 Supply and Fixing 150mm bore PVC slotted pipes double socketed in any length with suitable joints, laid in bore hole for recharge pit and like complete all as specified and directed 92 Boring 300mm dia for Bored cast in situ piles 16 metres in any kind of soil/soft rock and getting out and disposal of spoil to a distance 50 metres using suitable method complete all as specified and directed 93 FIRE FIGHTING SYSTEM 94 Supply and Fixing for 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 95 Supply and Fixing for 5 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 96 Supply and Fixing for 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 97 Supply and Fixing for 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 98 Supply and Fixing for Galvanized mild steel Fire bucket (Filled with dry sand & water) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter FIRE in black out side and handle with mounting bracket complete as specified and directed 99 Supply and Fixing for Galvanized mild steel Fire hook bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed 100 Supply and Fixing for Galvanized mild steel Fire Beater bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed
Contract Date: Mar 11, 2026 Contract Value : 14.98 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
7.
Rural Development #9629186 AOC
Tender For 1. Lwm Under Sbm Khadaki Tal-Daund, Dist-Pune Under Sbm Gramin Ii Open Class 3947380 - Sub Work 1 Leach Pit (5 HH) 19 unit leach pit -Excavation for foundation / pipe trenches in earth, soils of all types, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. MJP SSR 2023-24 P.No. 37 Iteam no. 1 2 Excavation for foundation / pipe trenches in Hard Murrum including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 2 3 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 5 4 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork, compaction, and curing, finishing Etc. complete. With initial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.1 (b)/ Page no.47 5 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete.Spec.No. :Bd.G.3 Page No.314.PWD SSR. 2022-23I.No.27.03 P. No. 197 6 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd. L.2 Page No. 368 PWD S.S.R. 2022-23 I.No. 32.04P.No. 209 7 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg./Sq.cm.MJP SSR 2023-24 Iteam 1 P.No. 74 8 PVC TEE (As per Market Rate) 9 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) MJP/ SSR/ 2023-24 / Section G Plain, reinforced and ready mix concrete / Item No.2/ Page no.47 10 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.8/ Page no.50 11 Sub Work 2Leach Pit (20 HH) - 11 Unit leach pit Excavation for foundation / pipe trenches in earth, soils of all types, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. MJP SSR 2023-24 P.No. 37 Iteam no. 1 12 Excavation for foundation / pipe trenches in Hard Murrum including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 2 13 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 5 14 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork, compaction, and curing, finishing Etc. complete. With initial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.1 (b)/ Page no.47 15 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete.Spec.No. :Bd.G.3 Page No.314.PWD SSR. 2022-23I.No.27.03 P. No. 197 16 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd. L.2 Page No. 368 PWD S.S.R. 2022-23 I.No. 32.04P.No. 209 17 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg./Sq.cm.MJP SSR 2023-24 Iteam 1 P.No. 74 18 PVC TEE (As per Market rate) 19 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) MJP/ SSR/ 2023-24 / Section G Plain, reinforced and ready mix concrete / Item No.2/ Page no.47 20 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.8/ Page no.50 21 Sub Work 3 - Tiger bio filter 50 KLD - 1 UNIT -Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259)0.0 to 1.5 m 22 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) 0.0 to 1.5 m 23 1.5 to 3.0 m 24 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259)1.5 to 3.0 m 25 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 26 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 27 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 28 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 29 Slabs / Landings / Vertical Walls / Waist Slabs / Steps for Staircase In RCC M-300 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 30 Chajjas / Parapets / Curtain Walls /Partition Walls / Pardies In RCC M-300 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) c) Corrosion Resistant Steel (Fe 500) 31 Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) 32 Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer-in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 33 Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B .W .G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts , lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 34 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 35 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 36 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curingcomplete. 37 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 38 Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 39 Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 40 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 41 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 42 Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle (50 x 50 x 6 mm) postat 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in (1:4:8) cement concrete block of 45 x 45 x 45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete 43 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH-PL/STP 44 Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 45 Fine and Coarse Screen (Manual) of size 1.65 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. 46 Grit pump Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) Supply 47 Erection 48 Raw Sewage Pumps Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below1 HP (Up to 9000 LPH) Supply 49 Erection 50 NaOCl Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10LPH Power Source Electric - Phase Single Material PP / PTFE(Teflon) / Voltage 230 Volt / Frequency 50Hz / Mixing Tank of 20 Ltrs capacity- 1 No / Dosing Pump - 1 Nos 51 Providing & erecting floor/wall mounted MCCB panel board, with door, suitable for four pole incoming 250A, 2 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)Supply 52 Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser.> 7.5 HP & Up to 12.5 HP Supply 53 Main power supply cable - Main DP to Control Panel cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed.3 core 16 sq mm Supply 54 Erection 55 Power cables Aluminium conductor 4 Core, XLPE / PVC insulated & armoured cable Supplying and erecting, XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 6 sq mm Supply 56 Erection 57 Copper conductor PVC insulated, Unarmoured control cableSupplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4 core 2.5 sq mm Supply 58 Erection 59 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).Raw Sewage pump to TBF Distribution Main header 63 mm. 60 PVC Specials- 10% 61 TBF Distribution 50 mm 62 PVC Specials- 10% 63 TBF Bed DistributionDistribution line for sripnklar20 mm 64 PVC Specials- 10% 65 Collection Tributory + Drain Pipe 63 mm. 66 PVC Specials- 10% 67 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance fromstores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint).63 mm, 50 mm and 20 mm uPVC pipe 68 Sluice valves Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 69 Reflux valves (non-return valves )Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 70 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of alllabour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.(Rate for all class of valves.) Sluice valves 71 Reflux valves (non-return valves ) 72 Ball Valve Plastic (Heavy Body) 73 Supplying ofSpecially designed container for holding Bio media including mixture of cocohusk,bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. 74 Stone Aggregate -5 mm to 10 mm 75 20 mm 76 40 mm 77 Transportation as per STATEMENT VI Including loading, unloading and stacking Aggregate 40 mm & above (25 Km) 78 Detailed Process Designing, Technology charges and commissioning of Sewage Treatment Plant (STP)based on Tiger Bio Filter (TBF) technologyas turnkey job 79 Sub work No 4 - Bio STP Plant (100 HH) - 2 unit -Excavation for foundation / pipe trenches in earth, soils of all types, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. MJP SSR 2023-24 P.No. 37 80 Excavation for foundation / pipe trenches in Hard Murrum including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.MJP SSR 2023-24 P.No. 37 (Bd-A4/259) 81 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) MJP/ SSR/ 2023-24 / Section A Excavation / Item No.18/ Page no.41 82 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork, compaction, and curing, finishing Etc. complete. With initial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.1/ Page no.47 83 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete.Spec.No. :Bd.G.3 Page No.314.PWD SSR. 2022-23I.No.27.03 P. No. 197 84 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd. L.2 Page No. 368 PWD S.S.R. 2022-23 I.No. 32.04P.No. 209 85 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg./Sq.cm.MJP SSR 2023-24 Iteam 1 P.No. 74110 MMPVC 6kg/cm2 PIPE 86 PVC TEE (As per Market Rate) 87 Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below i) Up to 100 user size (2.5 mx2.0 mx 1m), Capacity of Biodigester:-5000 liters, Area of top, bottom and side walls: - 19.00 sq.m, Area of partition walls: 8.00sq.m, Total weight of FRP: - 248.60 Kilogram, Bacteria inoculums quantity: - 1800 liters, Minimum thickness of side walls / top and bottom: 7mm, Number of inside partitions: - 4, Minimum thickness of partition wall: 4mm) PDW/ DSR/ 2022-23 / Section Water Supply and Sanitation / Item No.51.112.g/ Page no.381 88 Providing and filling in sand boxing in pipeline or for foundation with sand of approved quality including watering and compaction, etc. complete. Filling the gap between Shree Jee FRP tank and brick wall (Bd-A-13/264) MJP/ SSR/ 2023-24 / Section A Excavation / Item No.19/ Page no.41 89 Bar Screen:Supply of bar scren of following specifications SS flt size 25 mm x 3 mm thkOpening : 10 mmss angle frame : 25 mm x 25 mm x 3 mm thk 90 Sub work No 5 - Bio STP Plant (60 HH) - 1 unitExcavationforfoundation/pipetrenchesinearth,soilsofalltypes, including removing the excavated materialupto adistance of50 metres and lifts as below, stacking and spreading as directed, manual dewatering,preparingthebedforfoundationandexcludingbackfilling, etc. complete. MJP SSR 2023-24 P.No. 37 91 Excavationforfoundation/pipetrenchesinHardMurrumincluding removing the excavated material upto a distance of 50 M beyond the area andliftsasbelow,stackingasdirectedbyEngineer-in-charge,normal dewatering,preparingthebedforfoundationandexcludingbackfilling, etc. complete. (Bd-A4/259) 92 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to20cmthicklayersincludinghandpackingandcompacting,etc. complete.(Bd-A-12/264)MJP/SSR/2023-24/SectionAExcavation/ Item No.18/ Page no.41 93 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork,compaction,andcuring,finishingEtc.complete.Withinitial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.1/ Page no.47 94 ProvidingsecondclassBurntBrickmasonrywithconventional/I.S.type bricksincementmortar1:6inplinthasbackingincompositemasonry including bailing out water manually,striking joints,raking outjoints and watering etc Complete.Spec.No. :Bd.G.3 Page No.314.PWD SSR. 2022- 23I.No.27.03 P. No. 197 95 Providinginternalcementplaster12mmthickinsinglecoatincement mortar1:4withoutneerufinishtoconcreteorbricksurfaces,inall positions including scaffolding and curing etc. complete. Spec. No. Bd. L.2 Page No. 368 PWD S.S.R. 2022-23 I.No. 32.04P.No. 209 96 ProvidingandsupplyinginstandardlengthsISImarkrigidunplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local andcentraltaxes,transportation,freightcharges,inspectioncharges, loading,unloading,conveyancetothedepartmentalstores/siteand stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit typetobejointed withcement solvent).Working Pressure6 Kg./Sq.cm. MJP SSR 2023-24 Iteam 1 P.No. 74 110 MMPVC 6kg/cm2 PIPE 97 PVC TEE (As per market rate) 98 ProvidingandinstallingbiodigesterunitbasedonDRDOtechnology madeoffibrereinforcedplastic(FRP)havingcompositionandfollowing technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage ofpolyester resin: - 66.67% Water absorption(asperASTM):-0.30%FlammabilityasperASTMTensile strength:-115MPASpecificGravityat25degreecentigrade1.45Izod impactstrength:-65KJ/M2Heatdefection/distorttemperature:-65degC Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: - 100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm BacteriaimmobilizationPVCmattes(onallpartition)With DRDO TOTlicenseeandlatestbatchcertificate(month&yearofsupply)and capacity as below h) Up to 150 user size (3.2mx2.0mx1.25m), Capacity of Biodigester:-8000 liters, Area oftop, bottom and side walls: - 25.80 sq.m, Area of partition walls: 10.00sq.m, Total weight of FRP: - 397.08 Kilogram, Bacteria inoculums quantity: - 3200 liters, Minimum thickness of side walls/topandbottom:7mm,OneNumberofinsidepartitions:-4,Minimum thicknessofpartitionwall:4mmf)Upto80usersize(2.7mx1.5mx1m), Capacity of Biodigester:-4000 liters, Area of top, bottom and side walls: -16.50sq.m,Areaofpartitionwalls:4.50sq.m,TotalweightofFRP:-202.50Kilogram,Bacteriainoculumsquantity:-1400liters,Minimum thicknessofsidewalls/topandbottom:6mm,OneNumberofinside partitions: - 4, Minimum PDW/SSR/2022-23/SectionWaterSupplyandSanitation/Item No.51.112.f/ Page no.381 99 Providing and filling in sand boxing in pipeline or for foundation with sand ofapprovedqualityincludingwateringandcompaction,etc.complete. Filling the gap between Shree Jee FRP tank and brick wall (Bd-A-13/264) MJP/ SSR/ 2023-24 / Section A Excavation / Item No.19/ Page no.41 100 Bar Screen:Supply of bar scren of following specifications SS flt size 25 mm x 3 mm thkOpening : 10 mmss angle frame : 25 mm x 25 mm x 3 mm thk
Contract Date: Feb 20, 2026 Contract Value : 39.46 Lakh
Government Departments No of Bidders 4
Maharashtra View Result →
8.
Rural Development #9629185 AOC
Tender For 2. Lwm Under Sbm Khutbav Tal-Daund, Dist-Pune Under Sbm Gramin Ii Open Class 2814566 - Sub Work 1 Leach Pit (10 HH) 1 unit leach pit Excavation for foundation / pipe trenches in earth, soils of all types, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. MJP SSR 2023-24 P.No. 37 Iteam no. 1 2 Excavation for foundation / pipe trenches in Hard Murrum including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) MJP SSR 2023-24 P.No. 37 Iteam no. 2 3 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 5 4 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork, compaction, and curing, finishing Etc. complete. With initial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.1 (b)/ Page no.47 5 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete.Spec.No. :Bd.G.3 Page No.314.PWD SSR. 2022-23I.No.27.03 P. No. 197 6 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd. L.2 Page No. 368 PWD S.S.R. 2022-23 I.No. 32.04P.No. 209 7 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg./Sq.cm.MJP SSR 2023-24 Iteam 1 P.No. 74 110 MMPVC 6kg/cm2 PIPEMJP SSR 2023-24 Iteam no. b (iv) pg. no. 74 8 PVC TEE (As per Market Rate) 9 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) MJP/ SSR/ 2023-24 / Section G Plain, reinforced and ready mix concrete / Item No.2/ Page no.47 10 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.8/ Page no.50 11 Providing and filling in sand boxing in pipeline or for foundation with sand of approved quality including watering and compaction, etc complete (Bd-A-13/264) MJP SSR 2023-24 i. no 19 pg no 41 12 Sub Work 2Leach Pit (20 HH) - 2 Unit leach pit Excavation for foundation / pipe trenches in earth, soils of all types, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. MJP SSR 2023-24 P.No. 37 Iteam no. 1 13 Excavation for foundation / pipe trenches in Hard Murrum including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 2 14 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 5 15 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork, compaction, and curing, finishing Etc. complete. With initial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.1 (b)/ Page no.47 16 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete.Spec.No. :Bd.G.3 Page No.314.PWD SSR. 2022-23I.No.27.03 P. No. 197 17 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd. L.2 Page No. 368 PWD S.S.R. 2022-23 I.No. 32.04P.No. 209 18 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg./Sq.cm.MJP SSR 2023-24 Iteam 1 P.No. 74 19 PVC TEE (As per Market rate) 20 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) MJP/ SSR/ 2023-24 / Section G Plain, reinforced and ready mix concrete / Item No.2/ Page no.47 21 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.8/ Page no.50 22 Sub Work 3 Tiger bio filter 100 KLD -1 UNIT- Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259)0.0 to 1.5 m 23 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259)0.0 to 1.5 m 24 1.5 to 3.0 m 25 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 1.5 to 3.0 m 26 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 27 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 28 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 29 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 30 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 31 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 32 Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) 33 Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer-in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 34 Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B .W .G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts , lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 35 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 36 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 37 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curingcomplete. 38 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 39 Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 40 Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 41 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 42 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 43 Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle (50 x 50 x 6 mm) postat 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in (1:4:8) cement concrete block of 45 x 45 x 45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete 44 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH-PL/STP 45 Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 46 Fine and Coarse Screen (Manual) of size 1.65 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. 47 Grit pump Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) Supply 48 Erection 49 Raw Sewage Pumps Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) Supply 50 Erection 51 NaOCl Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10LPH Power Source Electric - Phase Single Material PP / PTFE(Teflon) / Voltage 230 Volt / Frequency 50Hz / Mixing Tank of 20 Ltrs capacity- 1 No / Dosing Pump - 1 Nos 52 Raw water pump MCCB Panel Boards Providing & erecting floor/wall mounted MCCB panel board, with door, suitable for four pole incoming 250A, 2 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) 53 Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 54 Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core 16 sq mm Supply 55 Erection 56 Aluminium conductor 4 Core, XLPE / PVC insulated & armoured cable Supplying and erecting, XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 6 sq mm Supply 57 Erection 58 Supplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner.4 core 2.5 sq mm Supply 59 Erection 60 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).Working Pressure 6 Kg/Sq.cm Raw Sewage pump to TBF Distribution Main header 75 mm. 61 PVC Specials- 10% 62 TBF Distribution 50 mm 63 PVC Specials- 10% 64 Distribution line for sripnklar20 mm 65 PVC Specials- 10% 66 Collection Tributory + Drain Pipe75 mm. 67 PVC Specials- 10% 68 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance fromstores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 63 mm, 50 mm and 20 mm uPVC pipe 69 Sluice valves Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 70 Reflux valves (non-return valves )Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 71 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of alllabour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.(Rate for all class of valves.)Sluice valves 72 Reflux valves (non-return valves ) 73 Ball Valve Plastic (Heavy Body) 74 Supplying ofSpecially designed container for holding Bio media including mixture of cocohusk,bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. 75 Stone Aggregate -5 mm to 10 mm 76 20 mm 77 40 mm 78 Transportation as per STATEMENT VI Including loading, unloading and stacking Aggregate 40 mm & above (25 Km) 79 Detailed Process Designing, Technology charges and commissioning of Sewage Treatment Plant (STP)based on Tiger Bio Filter (TBF) technologyas turnkey job
Contract Date: Feb 20, 2026 Contract Value : 28.14 Lakh
Government Departments No of Bidders 5
Maharashtra View Result →
9.
Rural Development #9629184 AOC
3. Lwm Under Sbm Wada Tal-Khed Dist-Pune Under Sbm Gramin Ii Open Class 3553419 - Leach Pit1 Near Grampanchayat Office(20 HH)unit leach pit -Excavation for foundation / pipe trenches in earth, soils of all types, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 2 Excavation for foundation / pipe trenches in Hard Murrum including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 3 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 4 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork, compaction, and curing, finishing Etc. complete. With initial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete 5 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete. 6 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg./Sq.cm. 8 PVC TEE 9 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) MJP/ SSR/ 2023-24 / Section G Plain, reinforced and ready mix concrete 10 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete 11 Providingandfillinginsandboxinginpipelineor for foundationwith sandof approvedquality includingwateringandcompaction, etc complete 12 Leach Pit 2 Behind KBP College for 20 HH Iems and rates same as per sr no 1 to 11 13 Leach Pit 3 Near Mahadev Temple for 20 HH Iems and rates same as per sr no 1 to 11 14 Leach Pit 4 Behind Primary Schoolfor 20 HH Iems and rates same as per sr no 1 to 11 15 Leach Pit 5 Near MSEB Power House for 20 HH Iems and rates same as per sr no 1 to 11 16 Leach Pit 6 Near Maruti Temple for 20 HH Iems and rates same as per sr no 1 to 11 17 Leach Pit 7 Near Nalla Bridge for 20 HH Iems and rates same as per sr no 1 to 11 18 Leach Pit 8 Near Primary Health Centre for 20 HH Iems and rates same as per sr no 1 to 11 19 Sub work 2 Tiger bio filter 100 KLD- 1 Unit Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 0.0 to 1.5 m 20 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) 0.0 to 1.5 m 21 1.5 to 3.0 m 22 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259)1.5 to 3.0 m 23 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 24 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 25 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 26 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 27 Slabs / Landings / Vertical Walls / Waist Slabs / Steps for Staircase In RCC M-300 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 28 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) c) Corrosion Resistant Steel (Fe 500) 29 Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) 30 Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer-in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 31 Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B .W .G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts , lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 32 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 33 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 34 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curingcomplete. 35 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 36 Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 37 Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 38 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 39 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 40 Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle (50 x 50 x 6 mm) postat 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in (1:4:8) cement concrete block of 45 x 45 x 45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete 41 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH-PL/STP 42 Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 43 Fine and Coarse Screen (Manual) of size 1.65 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. 44 Grit pump Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH )Supply 45 Erection 46 Raw Sewage Pumps Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) Supply 47 Erection 48 NaOCl Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10LPH Power Source Electric - Phase Single Material PP / PTFE(Teflon) / Voltage 230 Volt / Frequency 50Hz / Mixing Tank of 20 Ltrs capacity- 1 No / Dosing Pump - 1 Nos 49 Raw water pump MCCB Panel Boards Providing & erecting floor/wall mounted MCCB panel board, with door, suitable for four pole incoming 250A, 2 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) Supply 50 Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. > 7.5 HP & Up to 12.5 HP Supply 51 Supplying and erecting, Flat flexible submersible cable with, CopperPVC insulated, and PVC sheathed.3 core 16 sq mm Supply 52 Erection 53 Supplying and erecting, XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.Supply 54 Erection 55 Supplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4 core 2.5 sq mm Supply 56 Erection 57 Supplying, installing, testing and commissioning of 3 kWpONGRIDSolarPVSystem/PlantconsistingsolarPVpolycrystalline panel (335WpX09Nos.)andSolarON-GRIDInverterofsimilar capacity(THD<3%)withinterconnectingwires /cablesuptosolar ON GRID inverter, proper base plate, canopyboxtohouseInverterandnecessaryaccessoriesi.e.ACDB/ DCDB,MCBetc.wiringuptosolarInverterincasingandcapping, displayboard, signboard, twodistinct earthing, lightningarrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges forRMSsystem,completeuptonetmeter installationandexport to thegridwith5yearON-SITEwarrantyand fullycomprehe 58 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).Main header 75 mm. 59 PVC Specials- 10% 60 TBF Distribution 50 mm 61 PVC Specials- 10% 62 Distribution line for sripnklar20 mm 63 PVC Specials- 10% 64 Collection Tributory + Drain Pipe75 mm. 65 PVC Specials- 10% 66 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance fromstores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 65 mm, 50 mm and 20 mm uPVC pipe 67 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 68 Reflux valves (non-return valves )Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 69 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of alllabour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.(Rate for all class of valves.) Sluice valves 70 Reflux valves (non-return valves ) 71 Ball Valve Plastic (Heavy Body) 72 Supplying ofSpecially designed container for holding Bio media including mixture of cocohusk,bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. 73 Stone Aggregate -5 mm to 10 mm 74 20 mm 75 40 mm 76 Detailed proces Designing Technology charges and commisioningof Sewage treatment plant (STP) based on Tiger Bio Filter ( TBF) Technology as Turnkey Job 77 Transportation as per STATEMENT VI Including loading, unloading and stacking Aggregate 40 mm & above (25 Km)
Contract Date: Feb 20, 2026 Contract Value : 35.44 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
10.
Rural Development #9629183 AOC
4. Lwm Under Sbm Shiroli Tal-Khed Dist-Pune Under Sbm Gramin Ii Open Class 3376766 - Leach Pit 1 (10 HH) at ZP School -Excavation for foundation / pipe trenches in earth, soils of all types, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. MJP SSR 2023-24 P.No. 37 Iteam no. 1 2 Excavation for foundation / pipe trenches in Hard Murrum including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 2 3 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 5 4 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork, compaction, and curing, finishing Etc. complete. With initial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.1 (b)/ Page no.47 5 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete.Spec.No. :Bd.G.3 Page No.314.PWD SSR. 2022-23I.No.27.03 P. No. 197 6 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd. L.2 Page No. 368 PWD S.S.R. 2022-23 I.No. 32.04P.No. 209 7 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg./Sq.cm.MJP SSR 2023-24 Iteam 1 P.No. 74 8 PVC TEE (As per Market Rate) 9 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) MJP/ SSR/ 2023-24 / Section G Plain, reinforced and ready mix concrete / Item No.2/ Page no.47 10 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.8/ Page no.50 11 Providingandfillinginsandboxinginpipelineor for foundationwith sandof approvedquality includingwateringandcompaction, etc complete (Bd-A-13/264) MJP SSR 2023-24 i. no 19 pg no 41 12 Leach Pit 2 (10 HH) at Zakama devi temple items andrates are same as per sr no 1 to 11 13 Leach Pit3 (20 HH) at smashan bhumi right side -Excavation for foundation / pipe trenches in earth, soils of all types, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. MJP SSR 2023-24 P.No. 37 Iteam no. 1 14 Excavation for foundation / pipe trenches in Hard Murrum including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 2 15 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A4/259) Iteam no. 5 16 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork, compaction, and curing, finishing Etc. complete. With initial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.1 (b)/ Page no.47 17 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete.Spec.No. :Bd.G.3 Page No.314.PWD SSR. 2022-23I.No.27.03 P. No. 197 18 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd. L.2 Page No. 368 PWD S.S.R. 2022-23 I.No. 32.04P.No. 209 19 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg./Sq.cm.MJP SSR 2023-24 Iteam 1 P.No. 74 20 PVC TEE (As per Market Rate) 21 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) MJP/ SSR/ 2023-24 / Section G Plain, reinforced and ready mix concrete / Item No.2/ Page no.47 22 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete / Item No.8/ Page no.50 23 Providingandfillinginsandboxinginpipelineor for foundationwith sandof approvedquality includingwateringandcompaction, etc complete (Bd-A-13/264) MJP SSR 2023-24 i. no 19 pg no 41 24 Leach Pit4 (20 HH) at smashan bhumi right side items andrates are same as per sr no 13 to 23 25 Leach Pit5 (20 HH) in front of Jagadamba sport store items andrates are same as per sr no 13 to 23 26 Leach Pit6(20 HH) at sai krupa lawnsitems andrates are same as per sr no 13 to 23 27 Sub work 2 Tiger bio filter 100 KLD- 1 Unit Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 0.0 to 1.5 m 28 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) 0.0 to 1.5 m 29 1.5 to 3.0 m 30 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259)1.5 to 3.0 m 31 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 32 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 33 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 34 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 35 Slabs / Landings / Vertical Walls / Waist Slabs / Steps for Staircase In RCC M-300 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 36 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) c) Corrosion Resistant Steel (Fe 500) 37 Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) 38 Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer-in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 39 Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B .W .G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts , lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 40 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 41 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 42 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curingcomplete. 43 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 44 Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 45 Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 46 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 47 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 48 Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle (50 x 50 x 6 mm) postat 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in (1:4:8) cement concrete block of 45 x 45 x 45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete 49 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH-PL/STP 50 Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 51 Fine and Coarse Screen (Manual) of size 1.65 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. 52 Grit pump Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH )Supply 53 Erection 54 Raw Sewage Pumps Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) Supply 55 Erection 56 NaOCl Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10LPH Power Source Electric - Phase Single Material PP / PTFE(Teflon) / Voltage 230 Volt / Frequency 50Hz / Mixing Tank of 20 Ltrs capacity- 1 No / Dosing Pump - 1 Nos 57 Raw water pump MCCB Panel Boards Providing & erecting floor/wall mounted MCCB panel board, with door, suitable for four pole incoming 250A, 2 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) Supply 58 Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. > 7.5 HP & Up to 12.5 HP Supply 59 Supplying and erecting, Flat flexible submersible cable with, CopperPVC insulated, and PVC sheathed.3 core 16 sq mm Supply 60 Erection 61 Supplying and erecting, XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.Supply 62 Erection 63 Supplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4 core 2.5 sq mm Supply 64 Erection 65 Supplying, installing, testing and commissioning of 3 kWpONGRIDSolarPVSystem/PlantconsistingsolarPVpolycrystalline panel (335WpX09Nos.)andSolarON-GRIDInverterofsimilar capacity(THD<3%)withinterconnectingwires /cablesuptosolar ON GRID inverter, proper base plate, canopyboxtohouseInverterandnecessaryaccessoriesi.e.ACDB/ DCDB,MCBetc.wiringuptosolarInverterincasingandcapping, displayboard, signboard, twodistinct earthing, lightningarrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges forRMSsystem,completeuptonetmeter installationandexport to thegridwith5yearON-SITEwarrantyand fullycomprehe 66 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).Main header 75 mm. 67 PVC Specials- 10% 68 TBF Distribution 50 mm 69 PVC Specials- 10% 70 Distribution line for sripnklar20 mm 71 PVC Specials- 10% 72 Collection Tributory + Drain Pipe75 mm. 73 PVC Specials- 10% 74 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance fromstores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 65 mm, 50 mm and 20 mm uPVC pipe 75 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 76 Reflux valves (non-return valves )Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 77 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of alllabour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.(Rate for all class of valves.) Sluice valves 78 Reflux valves (non-return valves ) 79 Ball Valve Plastic (Heavy Body) 80 Supplying ofSpecially designed container for holding Bio media including mixture of cocohusk,bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. 81 Stone Aggregate -5 mm to 10 mm 82 20 mm 83 40 mm 84 Detailed proces Designing Technology charges and commisioningof Sewage treatment plant (STP) based on Tiger Bio Filter ( TBF) Technology as Turnkey Job 85 Transportation as per STATEMENT VI Including loading, unloading and stacking Aggregate 40 mm & above (25 Km)
Contract Date: Feb 20, 2026 Contract Value : 33.71 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
11.
Rural Development #9629182 AOC
5. Lwm Under Sbm Pait Tal-Khed Dist-Pune Under Sbm Gramin Ii Open Class 2930296 - Leach Pit1 Near near Ghadage catterers(20 HH)unit leach pit -Excavation for foundation / pipe trenches in earth, soils of all types, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 2 Excavation for foundation / pipe trenches in Hard Murrum including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 3 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 4 Providing and laying in situ 1:2:4 ( M-150 ) Grade of c.c. oftrap/ granite/ quartzite/ gneiss/ metal for foundation and bedding including dewatering, formwork, compaction, and curing, finishing Etc. complete. With initial lead of 1.50 M below / above G.L.as per MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete 5 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete. 6 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg./Sq.cm. 8 PVC TEE 9 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) MJP/ SSR/ 2023-24 / Section G Plain, reinforced and ready mix concrete 10 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) MJP/ SSR/ 2023-24 / Section G Plain,reinforced and ready mix concrete 11 Providingandfillinginsandboxinginpipelineor for foundationwith sandof approvedquality includingwateringandcompaction, etc complete 12 Leach Pit 2 at SOP Vasti for 20 HH Items and rates are same as per sr no 1 to 11 13 Leach Pit 3 at pait kadus road near ghat for 20 HH Items and rates are same as per sr no 1 to 11 14 Leach Pit 4 near PHC for 20 HH Items and rates are same as per sr no 1 to 11 15 Leach Pit 5 at Roundal Wadi roadfor 20 HH Items and rates are same as per sr no 1 to 11 16 Leach Pit 6 at Mahadev Templefor 20 HH Items and rates are same as per sr no 1 to 11 17 Leach Pit 7 Near Ramagiri Lawns for 20 HH Items and rates are same as per sr no 1 to 11 18 Sub work 5 Tiger bio filter 75 KLD- 1 Unit Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 0.0 to 1.5 m 19 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) 0.0 to 1.5 m 20 1.5 to 3.0 m 21 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259)1.5 to 3.0 m 22 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 23 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 24 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 25 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 26 Slabs / Landings / Vertical Walls / Waist Slabs / Steps for Staircase In RCC M-300 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 27 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) c) Corrosion Resistant Steel (Fe 500) 28 Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) 29 Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer-in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 30 Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B .W .G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts , lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 31 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 32 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 33 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curingcomplete. 34 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 35 Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 36 Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 37 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 38 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 39 Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle (50 x 50 x 6 mm) postat 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in (1:4:8) cement concrete block of 45 x 45 x 45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete 40 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH-PL/STP 41 Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 42 Fine and Coarse Screen (Manual) of size 1.65 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. 43 Grit pump Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH )Supply 44 Erection 45 Raw Sewage Pumps Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) Supply 46 Erection 47 NaOCl Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10LPH Power Source Electric - Phase Single Material PP / PTFE(Teflon) / Voltage 230 Volt / Frequency 50Hz / Mixing Tank of 20 Ltrs capacity- 1 No / Dosing Pump - 1 Nos 48 Raw water pump MCCB Panel Boards Providing & erecting floor/wall mounted MCCB panel board, with door, suitable for four pole incoming 250A, 2 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) Supply 49 Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. > 7.5 HP & Up to 12.5 HP Supply 50 Supplying and erecting, Flat flexible submersible cable with, CopperPVC insulated, and PVC sheathed.3 core 16 sq mm Supply 51 Erection 52 Supplying and erecting, XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.Supply 53 Erection 54 Supplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4 core 2.5 sq mm Supply 55 Erection 56 supplying, installing, testing and commissioning of 3 kWpONGRIDSolarPVSystem/PlantconsistingsolarPVpolycrystalline panel (335WpX09Nos.)andSolarON-GRIDInverterofsimilar capacity(THD<3%)withinterconnectingwires /cablesuptosolar ON GRID inverter, proper base plate, canopyboxtohouseInverterandnecessaryaccessoriesi.e.ACDB/ DCDB,MCBetc.wiringuptosolarInverterincasingandcapping, displayboard, signboard, twodistinct earthing, lightningarrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges forRMSsystem,completeuptonetmeter installationandexport to thegridwith5yearON-SITEwarrantyand fullycomprehe 57 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).Main header 63 mm. 58 PVC Specials- 10% 59 TBF Distribution 50 mm 60 PVC Specials- 10% 61 Distribution line for sripnklar20 mm 62 PVC Specials- 10% 63 Collection Tributory + Drain Pipe63 mm. 64 PVC Specials- 10% 65 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance fromstores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 63 mm, 50 mm and 20 mm uPVC pipe 66 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 67 Reflux valves (non-return valves )Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 68 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of alllabour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.(Rate for all class of valves.) Sluice valves 69 Reflux valves (non-return valves ) 70 Ball Valve Plastic (Heavy Body) 71 Supplying ofSpecially designed container for holding Bio media including mixture of cocohusk,bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. 72 Stone Aggregate -5 mm to 10 mm 73 20 mm 74 40 mm 75 Transportation as per STATEMENT VI Including loading, unloading and stacking Aggregate 40 mm & above (25 Km) 76 Detailed process Designing Technolgy chargesand commisining of Sewage Treatment Plant ( STP) based on Tiger Bio Filter ( TBF) technology as turnkey job
Contract Date: Feb 20, 2026 Contract Value : 29.25 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
12.
Rural Development #9589409 AOC
Tender For Liquid Waste Management Scheme At Dahiwel Tal Sakri - Liquid Waste Management -Sub Work 1 - 10 KLD Public Leach Pit Item No 1 - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 2 Item No 1 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 3 Item No 1 - Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) 0 to 1.5 m 4 Item No 2 :- Providing and laying in situ Cement Concrete M- 15 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38. 5 Item No 3 - Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 6 Item No 4 - Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Item No 5 - Providing and casting in situ C.C. of trap / granite/ quartzite /gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 8 Item No 6 - Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 9 Item NO 7 - Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 0.90 X 0.60 10 Item No 8 - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification по. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 11 Sub Work 2 - 125 KLD CAMUS SBT Sewage Treatment Plant Item No 1 - Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering. preparing the bed for foundation and excluding backfilling, etc complete. (BdA1/259) 0.0 to 1.5 m 12 1.5 to 3.0 m 13 3.0 to 4.5 m 14 Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259) 0.0 to 1.5 m 15 1.5 to 3.0 m 16 3.0 to 4.5 m 17 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259) 0.0 to 1.5 m 18 1.5 to 3.0 m 19 3.0 to 4.5 m 20 Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering. excluding backfilling, etc. complete by all means. (BdA6/259) 0.0 to 1.5 m 21 1.5 to 3.0 m 22 3.0 to 4.5 m 23 Providing dry trap/granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264) 24 Providing and laying in situ Cement Concrete M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. Bd E /1 Page No. 287 and B 7,for Beam/Braces/Lintels in PCC 25 Providing and layingin situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 26 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 27 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 28 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas/Parapets/Curtains Walls / Partition Walls/Pardies in RCC M 300 29 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) 30 Providing and fixing mild steel grill work for windows/ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) 31 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 32 Providing and applying whitewash in two coats on old/new plastered or masonry surfaces and asbestos cernent sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 33 Providing and applying colourwash of approved colour and shade in 136.95 one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc, complete. 34 Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc, complete. (BdA9/261 35 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 36 Transportation as per STATEMENT VI Including loading, unloading and stacking Screen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bend Quotation Item Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 37 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 38 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 9000 LPH Supply 39 2 HP upto 9000 LPH Erection 40 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 12000 LPH Supply 41 2 HP upto 12000 LPH Erection 42 NaOCI Chlorinator Pump Diaphragm Type/peristaltic type / Solenoid Max Flow Power source Eletric Phases Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 Nos Quotation Item Designing, Supplying, Installing, commissioning & testing of PLC Panel Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. Control Panel 43 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 44 Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 7.5 HP & upto 12.5 HP 45 Erection 46 Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core16sqm supply 47 Erection 48 Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/ on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 2.5 sqm mm supply 49 Erection 50 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Unarmoured control cable with ISI mark stranded/solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner 4 Core 2.5 sqm mm supply 51 Erection 52 Piumbing Item - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material l.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). Raw Sewage pump to10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates CAMUS Distribution Main header 75 mm 53 PVC Specials 54 Distribution 63 mm 55 PVC Specials 56 CAMUS Collection 75 mm 57 PVC Specials 58 Collection tributory 63 mm 59 PVC Specials 60 CAMUS Distribution 63 mm 61 PVC Specials 62 Plumber 63 Helper 64 Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass) Raw Sewage pump 80 mm 65 Providing and supplying ISI mark CI D/F reflux valves (non return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.5.5312 Part I (1984) Without by pass arrangement PN 1 Raw Sewage pump 66 Providing, laying, spreading in layers stone aggregates of specific size as a Bio media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. complete Supplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 67 As Per Rate Analysis Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including 3.0 conveying & stacking 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 68 Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd 69 Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete 70 Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness). (As per P&G DSR 2022-23 Items of garden work, Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR required variety of lawn (free from weeds / diesease etc.) Cynadon/paspalum/selection for 1 sqm. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work, Sr No.46) 71 Excavation for planting lawn/shrub/flower bed/hedges/ edges/canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.3), Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.13), Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flower bed/ hedges/edges/canna bed/ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work, Sr No.23), Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/selection) (As per P&G DSR 2022-23 Items of garden work, Sr No.28) 72 Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,. Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018 73 Providing Energy Meter Application Fees Energy Meter Fee
Contract Date: Feb 17, 2026 Contract Value : 46.51 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
13.
Rural Development #9589408 AOC
Tender For Liquid Waste Management Scheme Dighave Tal Sakri Dist Dhule - Liquid Waste Management -Sub Work 1 - 10 KLD Public Leach Pit Item No 1 - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 2 Item No 1 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 3 Item No 1 - Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) 4 Item No 2 :- Providing and laying in situ Cement Concrete M- 15 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38. 5 Item No 3 - Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 6 Item No 4 - Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Item No 5 - Providing and casting in situ C.C. of trap / granite/ quartzite /gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 8 Item No 6 - Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 9 Item NO 7 - Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 0.90 X 0.60 10 Item No 8 - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification по. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 11 Sub Work 2 - 75 KLD CAMUS SBT Sewage Treatment Plant Item No 1 - Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering. preparing the bed for foundation and excluding backfilling, etc complete. (BdA1/259) 0.0 to 1.5 m 12 1.5 to 3.0 m 13 3.0 to 4.5 m 14 Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259) 0.0 to 1.5 m 15 1.5 to 3.0 m 16 3.0 to 4.5 m 17 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259) 0.0 to 1.5 m 18 1.5 to 3.0 m 19 3.0 to 4.5 m 20 Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering. excluding backfilling, etc. complete by all means. (BdA6/259) 0.0 to 1.5 m 21 1.5 to 3.0 m 22 3.0 to 4.5 m 23 Providing dry trap/granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264) 24 Providing and laying in situ Cement Concrete M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. Bd E /1 Page No. 287 and B 7,for Beam/Braces/Lintels in PCC 25 Providing and layingin situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 26 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 27 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 28 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas/Parapets/Curtains Walls / Partition Walls/Pardies in RCC M 300 29 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) 30 Providing and fixing mild steel grill work for windows/ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) 31 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 32 Providing and applying whitewash in two coats on old/new plastered or masonry surfaces and asbestos cernent sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 33 Providing and applying colourwash of approved colour and shade in 136.95 one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc, complete. 34 Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc, complete. (BdA9/261 35 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 36 Transportation as per STATEMENT VI Including loading, unloading and stacking Screen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bend Quotation Item Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 37 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 38 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 9000 LPH Supply 39 2 HP upto 9000 LPH Erection 40 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 12000 LPH Supply 41 2 HP upto 12000 LPH Erection 42 NaOCI Chlorinator Pump Diaphragm Type/peristaltic type / Solenoid Max Flow Power source Eletric Phases Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 Nos Quotation Item Designing, Supplying, Installing, commissioning & testing of PLC Panel Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. Control Panel 43 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 44 Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 7.5 HP & upto 12.5 HP 45 Erection 46 Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core16sqm supply 47 Erection 48 Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/ on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 2.5 sqm mm supply 49 Erection 50 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Unarmoured control cable with ISI mark stranded/solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner 4 Core 2.5 sqm mm supply 51 Erection 52 Piumbing Item - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material l.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). Raw Sewage pump to10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates CAMUS Distribution Main header 75 mm 53 PVC Specials 54 Distribution 63 mm 55 PVC Specials 56 CAMUS Collection 75 mm 57 PVC Specials 58 Collection tributory 63 mm 59 PVC Specials 60 CAMUS Distribution 63 mm 61 PVC Specials 62 Plumber 63 Helper 64 Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass) Raw Sewage pump 80 mm 65 Providing and supplying ISI mark CI D/F reflux valves (non return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.5.5312 Part I (1984) Without by pass arrangement PN 1 Raw Sewage pump 66 Providing, laying, spreading in layers stone aggregates of specific size as a Bio media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. complete Supplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 67 As Per Rate Analysis Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including 3.0 conveying & stacking 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 68 Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd 69 Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete 70 Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness). (As per P&G DSR 2022-23 Items of garden work, Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR required variety of lawn (free from weeds / diesease etc.) Cynadon/paspalum/selection for 1 sqm. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work, Sr No.46) 71 Excavation for planting lawn/shrub/flower bed/hedges/ edges/canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.3), Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.13), Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flower bed/ hedges/edges/canna bed/ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work, Sr No.23), Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/selection) (As per P&G DSR 2022-23 Items of garden work, Sr No.28) 72 Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,. Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018
Contract Date: Feb 17, 2026 Contract Value : 34.89 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
14.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
15.
Public Administrative Department #9493970 Technical Bid
Tender For Place making work from Naja Market Novelty Square to Municipal Corporation office in Hazratganj - DISMANTLING WORK 2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 3 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix) 4 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (in cement mortar) 5 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 6 Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (BITUMINOUS ROAD) 7 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 8 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 9 Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge 10 CIVIL WORK 11 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 12 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. 13 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 14 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc for mass concrete 15 Providing & Laying Designer Pavers 100mm x 100mm with thickness ranging from 70-90mm of approved shape and complete as per direction of Engineer-in- Charge. including transport ,loading ,unloading and conveyance of material from available source to work site, including labour charges for fixing and pointing etc., complete 16 Sand FillingFilling in foundation trenches as per drawing and technical specifications clause 305.3.9 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 19 Cement mortar 1:3 (1 cement :3 coarse sand) 20 12 mm cement plaster of mix : 21 1:4 (1 cement: 4 coarse sand) 22 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete. 23 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 24 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 25 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand): 25mm thick 26 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 27 Supply and installation of 60 L: AUX Waste Bin of material Stainless Style with Contemporary Mounting: Root fixed, Surface/baseplate fixed, wall/post mounted with Features: Ashtray, complete with foundation as per the direction of the Engineer in charge 28 Providing and laying drain gratings on both sides of the road anlong with tree grating wherever required. 29 Drain Grating - FRP GRATING (DRAIN)SIZE: 366 x 1001 x 30 H MMTHICKNESS: 6/7 MM 30 Tree Grating - SIZE: 800 x 800 x 400 (Inner Dia’) MMTHICKNESS: 30 MM 31 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Size of Tile 600 x 1200 mm 32 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 33 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia 34 Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications 35 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 36 Centering and shuttering including strutting, propping etc. and removal of form for : Walls 37 Steel in kg 38 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 39 For vertical surface two coats @ 0.70 kg per sqm per coat 40 For horizontal surface one coat @1.10 kg per sqm. 41 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineerin-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately). 12 mm thick one side Pre-laminated particle board (decorative lamination on oneside and other sides balancing lamination) grade -1, medium density flat pressed,three layer particle board FPT - I or graded wood particle board FPT-1 conformingto IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 andpre-laminated conforming to IS : 12823, Grade -1, Type II marked 42 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia 43 Boaring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 part I, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer In charge, up to 150 meter depth below ground level. 300 mm diaAll type of soil (DAR 23.2.1.1 based)Sanction Rate 44 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia 45 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness5.40 mm 46 Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm in the recharge pit, over the existing layer of boulders, in required thickness for all leads & lifts all complete as per direction of Engineer in charge. DAR 23.6 47 brick ballast 40 mm class 150 48 brick ballast 40 mm class 150 49 Providing & fixing sand stone Single piece ornamental bench of approved design pattern (1200x450x450MM) and specifications including, all materials, labour and T & Petc. required for proper completion of work as directed by engineer - in -charge 50 Supply and fixing of Bollard made from mid steel with CNC machine finishingwith 140mm outer diameter , thickness of 3mm r and 1100mm Height . Expose height 900mm from above Ground level and fixed the remaining 200mm below the GL. three number of circular rib of R06mm radius are provided at the top . The whole product is power coated black colour as per standard recommendation of Engineer. For fixing the Bollards with M10 cement concrete footing of minimum dimension 20cmx20cmx20cm,with base plate, anchor rods complete. 51 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 52 Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bilingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applyingHeat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee Support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge. 53 Mandatory/ Regulatory sign boards of 900 mm diametrewith support length of 3750 mm 54 Providing and fixing StandAlone Signage in Marble of approved thickness with powder coated 10-12mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 size Hindi: Krutidev Fontwith min. 36 size, PSR 55 Signage-A Informative Signage of Sandstone/Marble of size (1200x2100)MMvisibly from both side, PSR 56 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab except colour of Black, Cherry/Ruby Red or equivalent 57 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 58 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 59 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. 60 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 61 Supplying, fixing and commissioning of Hydraulic (Retractable) Bollards as per specification 62 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. 63 Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 64 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 65 Labour rate for the mentioned item. Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Double arm bracket 1 Mtr length in 1:2:4 RCC foundationbolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. 66 Providing & fixing ofConcrete Drain Covers Sandstone Colour550X750X50MM Colour: Sandstone Ultra High Performance Pigmented Concrete With Steel Fiber Reinforcement Load Capacity Suitable for 10 Tonne Pigmented Concrete Bayferrox Lanxess Fe203 Colour Index 77491.0000etc all complete in direction of engineer in charge 67 Providing & fixing of Concrete drain cover Concrete Drain Covers Sandstone Colour 550X750X50MM Ultra High Performance Pigmented Concrete With Steel Fiber Reinforcement Load Capacity Suitable for 40 Tonne Vehicle Passing Bayferrox Lanxess Fe203 Colour Index 77491.0000 etc all complete in direction of engineer in charge 68 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fastenersat both ends. The work shall be executed as perdrawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job.The barricading shall not be removed without prior approval of Engineerin- Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). 69 PLUMBING OF AREA- HAZRATGANJ NAJA MARKET ROAD, PLAZA, CHAURAHA, TRILOKNATH ROAD , CAPPER ROAD, DR. SOUJA ROAD, DAYNIDHAN ROAD - PLACEMAKING AND REDEVELOPMENT 70 SANITARY FIXTURES & ACCESSORIES 71 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. 72 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White 73 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require 74 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 75 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 76 32 mm dia (for wash basin) 77 Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 78 Providing & fixingtoilet paper holder. C.P. Brass 79 WATER SUPPLY PIPES AND FITTINGS 80 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. 81 Internal work exposed on wall 82 40mm nominal outer dia pipes 83 50mm nominal outer dia pipes 84 Providing, fixing chlorinated polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 85 Concealed work including cutting chase and making good the wall etc. 86 15mm nominal outer dia pipes 87 20mm nominal outer dia pipes 88 25mm nominal outer dia pipes 89 32mm nominal outer dia pipes 90 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 91 40 mm nominal bore 92 50 mm nominal bore 93 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions.45 cm length: 15mm nominal bore 94 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. 95 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. 96 Providing & fixing 15 mm nominal bore C.P. brassstop cock (concealed)of standard designandof approvedmakeconforming to IS : 8931. 97 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. 98 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 99 Constructing brick masonry chamber 300 x 300x500mm, insidewithF.P.S. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for StopCock, withC. I. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 100 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 101 150 x 100 mm. size P type 102 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 103 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 104 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 105 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. 106 PN - 10 Pipe, 50 mm OD (SDR-11) 107 PN - 10 Pipe, 75 mm OD (SDR-11) 108 PN - 10 Pipe, 110 mm OD (SDR-11) 109 TOTAL ( SCHEDULED ITEM ) 110 PART B(NON SCHEDULED ITEMS - AS PER MARKET RATES) 111 SUPPLYOFSANITARY FIXTURES, ACCESSORIESANDBATHROOMFITTINGS 112 Providing & fixing of white vitreous china urinal partition for half stall urinals. (Jaquar or equivalent) 113 Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) 114 P-Trap type Floor Trap 110 x 75 mm 115 Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. 116 Providing & fixing 50 mm. dia. G.I elbow (drain point) in the toilet floor including50 mm dia. C.P. waste jali complete as required. 117 C. INTERNAL ELECTRICAL WORKS -HAZRATGANJ NAJA MARKET ROAD, PLAZA, CHAURAHA, TRILOKNATH ROAD , CAPPER ROAD, DR. SOUJA ROAD, DAYNIDHAN ROAD - PLACEMAKING AND REDEVELOPMENT 118 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 119 Group A 120 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed steel conduit as required 121 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 122 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 123 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 124 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 125 Supply and drawing co-axal TV cable RG-6 Grade, 07 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PCV sheath in the axisting surface/recessed steel/PVC conduite as required. 126 1 Pair, 0.5mm dia annealed copper conductor, FRLS PVC insulated, unarmoured, Telephone cable 127 Supplying and fixing following Suitable size GI Box with Moudular plate and cover infront on surface or recess, including providing and fixing 2 nos 3 pin 5/6 A moduler socket outlet and 2 nos. 5/6 A moduler switch, connection etc. as required. ( for light pluges to be used in non residentions, painting etc. as required. 128 Supplying and fixing following Suitable size GI Box with Moudular plat and cover infront on surface or recess, including providing and fixing 25 A moduler socket outlet and 25 A moduler SP MCB C Curve including connections, painting etc. as required. 129 Supplying and fixing PVC batten/ angle holder including connections etc as required. 130 Supply and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 131 5/6 A Switch 132 2 way 5/6 A switch 133 Telephone socket outlet 134 TV Antenna socket outlet 135 Bell Push 136 Supplying and fixing following size/ modules, GI box along withmodular base & cover plate for modular switches in recess etc as required. 137 1 or 2 Module (75mmX75mm) 138 3 Module 100mmX75mm) 139 4 Module 125mmX75mm) 140 6 Module 200mmX75mm) 141 8 Module 125mmX125mm) 142 12 Module 200mmX150mm) 143 Supplying and fixing following modular base & cover plate on existing moduler metal boxes etc. as required. 144 1 or 2 Module 145 3 Module 146 4 Module 147 6 Module 148 8 Module 149 12 Module 150 Supplying and fixing of following sizes of pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 151 25mm 152 32mm 153 Supply, installation, testing and commissioning of 1200mm sweep, BEE 5 Star rated, ceiling fan with brush less direct current (BLDC) Motor, class of insulation: B, 3 nos. Blades 30cm long down rod, 2 nos, canopies shackle kit, safety rope, copper winding, power factor not less than 0.9 service value (CM/M/W) Minimum 6.00, air delivery minimus 210 cm/min 350 rpm (tolerance as per IS:374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washer, temperaure rise = 75Degree C (max.), insulation resistance more than 2 mega ohm, Suitable for 230 V, 50Hz single phase AC supply, earthing etc. Complete as required. 154 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as 155 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. asrequired. 156 Supply and fixing call bell/Buzzer suitable for single phase,230V, Complete as required. 157 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 158 Supplying and fixing following way, Horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 159 4 way(4+12) , Double door 160 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 161 16 way , Double door 162 Supply andfixing following rating, double pole, 240 V isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. 163 40 A 164 Supply andfixing following rating, four pole, 415 V isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. 165 63 A 166 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 167 Single Pole 168 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 169 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe et 170 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as 171 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 172 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 173 PART B - NON - SCHEDULED ITEMS (AS PER MARKET RATES ) 174 Supply & erection of AC 230/250 volts 50 hz Exhaust fans including provding nut bolts mounting frame and other accessories including connection etc complete as required as per direction of E /I make:- Havells / Cromption / USHA 175 300 mm Sweep 900 RPM 176 Supply & fixing of following white RJ 45 cat 6 data outlet / information outlet ETL verified to meet exceed TIA / ETA 177 Supply & fixing of following Telephone outlet 178 Supply & installation of CCTV / Suvillance system. (Honeywell 20 channel NVR full HD IP based- 01 nos, IP Honeywell dome camera 2MP with night vision- 8 nos., IP Honeywell 2 MP HD Bullet camera with night vision- 8 nos.) 179 Supply of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete, including tube on surface complete in all respect. 180 1 X 22 W 181 Supply ofrecess/Surface/Pendent mounting round 12 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. (Make: Wipro) 182 LED Fancy Gate Light, Aluminium, 12 W 183 Earth work in excavation bymechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.All kinds of soil 184 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5kmalso includingrammingandwateringoftheearthinlayersnot exceeding20cmintrenches,plinth,sidesoffoundationetc.complete. 185 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 186 Providingandlayinginpositioncementconcreteofspecified grade excluding the cost of centering and shuttering - All work uptoplinthlevel:1:3:6(1Cement:3coarsesand(zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 187 Brick work with common burnt clay F.P.S. (non modular) bricks of class -150 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 188 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in- charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement. M-25 Grade Concrete 189 SteelreinforcementforR.C.C.workincludingstraightening, cutting,bending,placinginpositionandbindingallcomplete Thermo-Mechanically Treated bars of grade Fe-500D or more 190 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 191 Providingandapplyingwhitecementbasedputtyofaverage thickness1 mm, of approved brandand manufacturer,over the plasteredwallsurfacetopreparethesurfaceevenandsmooth 192 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied@ 2.20kg/10 sqm 193 ProvidingandlayingfactorymadechamferededgeCement Concretepaverblocksin footpath, parks,lawns, driveways or light trafficparking etc,of requiredstrength, thickness& size/ shape, made by table vibratory method using PU mould, laid in requiredcolour&patternover50mmthickcompactedbedof sand, compacting and proper embedding/laying of inter locking paverblocksintothesandbeddinglayerthroughvibratory compactionby usingplatevibrator,fillingthe jointswithsand andcuttingofpaverblocksasperrequiredsizeandpattern, finishing and sweeping extra sand. complete all as per directionof Engineer-in-Charge. 194 60mm thick cement concrete paver block of M-35 gradewith approved colour, design & pattern (Square and Rectangular shape) 195 80mmthickC.C.paverblockofM-35gradewithapproved color design and pattern.(Square and Rectangular shape) 196 Providing and laying matt finished vitrified tile of size 100x100x16mmhavingwaterabsorptionlessthan0.5%and conformingtoIS:15622ofapprovedmakeinallcoloursand shadesinoutdoorfloorssuchasfootpath,courtyardmulti modelsetc.,laidon20mmthickbaseofcementmortar1:4 (1cement:4coarsesand)inallshapes&patternsincluding groutingthejointswithwhitecementmixedwithmatching pigments etc. complete as direction of Engineer-in-Charge. 197 Providingandlayinginpositonreadymixedorsitebatched design mix cement concrete for reinforcedcement concrete work; using coarse aggregate and aggregate derived from natural sources,PortlandPozzolana/OrdinaryPortland/PortlandSlag cement,admixtures in recommended proportons as per IS:9103 to accelerate / retard sieving of concrete, to improve durability and workabilitywithoutimpairingstrength;includingpumpingof concretetositeoflaying,curing,carriageforallleads;but excludingthecostofcentering,shufering,fnishing andreinforcementasperdirectonoftheengineer-in-charge;for the following grades of concrete.Note: Extra cement up to 10% of the minimumspecified cement content in design mix shall be payableseparately.Incasethecementcontentindesignmix ismore than 110% of the specified minimum cementcontent, the contractor shall have discreton to eitherre-design the mix or bear the costofextracementConcreteofM25gradewithminimum cement contentof 330 kg /cumOne CubicMetreConcrete of M30 grade with minimum cement contentof 350 kg /cumOne CubicMetreConcrete of M35 grade with minimum cement contentof370kg/cumOneCubicMetreConcreteofM40grade with minimum cement contentof 390 kg /cumOne CubicMetreConcrete of M50 198 Concrete of M30 grade with minimum cement contentof 350 kg 199 Applying stamping finsh of the top surface of freshlylaid plain / reinforced cement concrete of specifedgrade in portco, side walks, drive ways, pool decks andopen yard as per directon of the Engineer-in-Charge.* The concrete shall be placed and screened to thefnished grade and •oated to the uniform surface byusing standard fnishing techniques. approved colorhardener @2.7 kg/sqm shall be applied evenly to thesurface of the fresh concrete by the dry shake methodby sprinkling in twoor more shakes foated aer eachshake and trowel only after final coating. The approved released agent @ 0.113 Kg/Sqm shall be applied evenly to the trowelled surface before stamping or the said release agent can be applied to the fexiblepolyurethene stamp moulds of approved design and inrequired sizes to achieve fnal stamping pattern. These stampings shall be placed on the surface of concrete in three to four pieces at a time and tapped gently with rammers of sufcient size and weight to leave properstamp marks and the process repeated for the remaining concrete surface till the whole surface to bestamped is completed within the time while the concrete is in plastic stage of setting.After stamping, the curing shall be done as permanufacturers specifcatons. After inital curing theimprinted joints shall be grouted using cement slurrymixed with color hardener as per the requirement. Thesurface shall be sealed by applying acrylic based sealernot less than 0.167 litre/Sqm on fnished surf The constructon joints shall be provided by grovecutting of size 4 mm x 20 mm in panel size 3 m x 3 m orlesser as per the site conditons and flling the samewith 10 mm baker rod and providing & laying (PU)Polyurethane based joint sealer of approved make asper manufacturer’s specifcatons and fnished byapplying polyurethene resin based topprotectve clearcoat of minimum 80 micron applied with rollers onproperly cured and dry clean surface. (The cost ofconcrete for flooring is not included in the item, whichshall be paid for seperately).One SquareMetreSupplying and laying of Uni-Axial Woven PolysterGeogrid conforming to MORTH 3100 and IRC113, as soilreinforcement/basal reinforcement includingaccessories like te-strips, nuts & bolts and loops/lugsfor joining reinforcing elements with the facia pannels,overlaps and other protectve elements for synthetcgeo-grids and all other actvites required for reinforcedsoil walls, slopes etc complete as per designrequirements, manufacturer specifcatons and as perdirecton of engineer-in- charge.Uni Axial Woven polyster geogrid of minimum tensilestrength 40KN/m in the Longitudinal directon and 20KN/m in the Transverse directon.One SquareMetre 200 62mmthickcementconcreteflooringwithconcretehardener topping,underlayer50mmthickcementconcrete1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)andtoplayer12mmthickcementhardenerconsistingof mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’sspecifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 201 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 202 Supplying & Laying of Precast Saucer Drain 150 thick 300 mm wideinluding sand bed etc all complete in direction of engineer in charge 203 Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 204 Providing, laying and making kerbchannel 30cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the topsmoothetc.completeandasperdirectionofEngineer-in- 205 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and fillingwith150mmthickjamunasand,includingspreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. 206 Providing andfixing10x10x10cmGranitestoneblockhandcut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mmwidefilledwithsamemortarincludingruledpointingetc. complete as per direction of engineer-in-charge. 207 Providing and laying Polished Granite stone flooring in required design and patterns,inlinearas wellas curvilinearportionsof the building all complete as per the architectural drawings with 18mmthickstoneslabover20mm(average)thickbaseof cementmortar1:4(1cement:4coarsesand)laidandjointed with cement slurry and pointing with white cement slurry admixedwithpigmentofmatchingshadeincludingrubbing, curingandpolishingetc. all completeas specified andas directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 208 ProvidingandlayingflamedfinishGranitestoneflooringin requireddesignandpatterns,inlinearaswellascurvilinear portionsofthebuildingallcompleteasperthearchitectural drawingswith18mmthickstoneslabover20mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointedwith cementslurry and pointing withwhite cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirectedbytheEngineer-in-Charge:Flamedfinishgranite stoneslabJetBlack,CherryRed,EliteBrown,CatEyeor equivalent 209 Painting runway/taxi track/apron marking with adequatenos of coats to give uniform finish with road marking paint of superior makeasapprovedbytheEngineer-in-charge,i/ccleaningthe surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete.New work (Two or more coats) 210 Layingoldcementcocreteinterlockingpaverblocksofany design/shapelaidin requiredline,level,curvature,colourand pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer in-charge. (Old CC paver blocksshall be supplied by the department free of cost). 211 Layingatorneargroundleveloldkerbstonesofalltypesin positiontotherequiredline,levelandcurvature,jointedwith cement mortar 1:3 (1 cement : 3 coarse sand), including making jointswithorwithoutgrooves(thicknessofjoints,exceptat sharpcurve,shallnotbemorethan5mm),includingmaking drainage opening wherever required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb edging shallbemeasuredforpayment).(Oldkerbstonesshallbe supplied by the department free of cost) 212 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fastenersat both ends. The work shall be executed as perdrawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job.The barricading shall not be removed without prior approval of Engineerin- Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). 213 Centeringandshutteringincludingstrutting,proppingetc.andremoval of form for 214 Walls(anythickness)includingattachedpilasters,butteresses,plinth and string courses etc. 215 Providing&fixingofcementconcreteBollardsM-30GradeR.C.C.150mmdiaincludinggoutinginfoundation750mm height including all necessary T&P etc all complete in directio of 216 Repairing of Existing Canopy including PPGL Sheet & necessarymember &Screw,nut, bolts,washer ,including paintingpolishingetcallcompleteindirectionofengineerin charge. 217 Boring/drillingborewellofrequireddia for casing/ strainer pipe, by suitable methodprescribedinIS:2800(partI), including collecting samples from different strata, preparing and submitting stratachart/borelog,includinghire& running charges of all equipments, tools, plants&machineriesrequiredforthe job, all complete as per direction of Engineer-in-charge,upto90metredepth below ground level. 218 300 mm dia 219 Supplying, assembling, lowering and fixinginverticalpositioninborewell, unplasticizedPVCmediumwellcasing (CM) pipe of required dia, conforming to IS:12818,includingrequiredhireand labourcharges,fittings&accessories etc.allcomplete,foralldepths,asper direction of Engineer -in-charge. 220 150 mm nominal size dia 221 Supplying, assembling, lowering and fixinginverticalpositioninborewell unplasticizedPVCmediumwellscreen (RMS) pipes with ribs, conforming to IS: 12818, includinghire & labour charges, fittings&accessoriesetc.allcomplete, for all depths, as per direction ofEngineer-in-charge. 222 150 mm nominal size dia 223 Gravelpackingintubewellconstruction inaccordancewithIS:4097,including providing gravel fine/ medium/ coarse, in requiredgrading&sizesasperactual requirement,allcompleteasper direction of Engineer-in-charge. 224 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit) 225 withrequiredcapacityaircompressor, running the compressor for required timetill wellis fullydeveloped, measuringyieldofwellby“V”notch methodorany otherapprovedmethod, measuring static level & draw down etc. bystepdrawdownmethod,collecting water samples & getting tested in approvedlaboratory,i/cdisinfectionof tubewell,allcomplete,includinghire& labourchargesofaircompressor,tools & accessories etc., all as per requirement and direction of Engineer-incharge. 226 Providingandfixingsuitablesize threadedmildsteelcaporspotwelded platetothetopofborewellhousing/ casing pipe, removable as per requirement, all complete for borewell of 227 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm 228 ProvidingandfixingBailplug/Bottom plug of required dia to the bottom of pipe assemblyoftubewellasperIS:2800 (part I). 150 mm dia. 229 Supplyofsubmersiblepumpofmake KSB / Crompton / kirloskar 7.5HP with control panel, support wire etc. 230 Supply and laying of aluminium conductorPVCinsulatedarmoured served sheathed cables 1100 Volts grade ata depth of 750 mm below groundleveloveracushionof75mm. thick sand all around and protectedwithburntbricksonsidesandontop. Onsurfacethecablerunshallbe fixed onM.S.clampsetc.ofsuitablesizeor asdirectedbytheEngineer-Incharge, complete in allrespect. The armouring of the cable shallbeproperly connectedwiththe earthonductor by clamps etc.submersibble cable from pump panel to 231 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. 32 mm dia nominal bore 232 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 233 Supply of 100mm dia Johnson screen. 234 Providing and stacking of Nyctanthes arbor- tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer- 235 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 236 Providing and stacking of Plumeria rubra of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of 237 Providing and stacking of Ficus panda of height 90-105cm.with10-12branchesandhealthy foliage,wellformedincementpotsofsize30 cm as per direction of the officer-in-charge.. 238 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen pots of size 25 cm as per direction of the officer- 239 Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushtyshape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. 240 Providing and stacking of Tradescantia zebrina having in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 241 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size ofPoly bags & as per direction of the officer-in- 242 Providing and stacking of Asparagus sprengeri of height 15 cm to 20 cm, full of leafy branches in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge.. 243 Providing and stacking of Ophiopogon jaburan ( variegated ), full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 244 Providing and displaying of Croton Petra Bangalore variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer- 245 Making tree guard 53 cm dia and 1.3 m high as per design from empty coal tar drums, supplied free by the department, including providing and fixing 2 nos M.S. sheet rings 50 x 0.5 mm fixed withrivetscompleteinallrespectsincluding painting inside and outside of tree guard with: Two or more coats of synthetic enamel paint of approved quality shade over a priming coat 246 Trenching in ordinary soil up to required depth includingremovalandstackingofserviceable materials and then disposing of as directed and spreading earth & neatly levelling, breaking clodsetc.andmakingthetrenchedareawith designedmounds,pathsandsittingspacesetc. toproperlevelsbyfillingwithearthorearth mixed with manure and properly watering completeworkinrequiredtopographyasperdrawing & specifications. 247 Supplyingandstackingofgoodearthatsite includingroyaltybutincludingcarriage 20 km (earthmeasusredinstackswillbereducedby 248 Supplyingandstackingatsitedumpmanure from approved source,including carriage up to 1 km (manure measured in stacks will be reduced by8% for payment) 249 Mixing earth and manure in specified proportion or as directed. 250 Roughdressingthetrenchedgroundincluding breaking the clods. 251 Fine dressing the ground 252 Spreadingof mixedgoodearthandmanurein specifiedproportionsasaboveandinrequired thickness. 253 Providing&layingSelectionno.1grassturf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothenandlightwateringthesame,asperdirection of officer in charge 254 Preparation of mounds of various size and shape by available excavated / supplied earth in layers notexceeding20cmindepth,breakingclods, wateringofeachlayer,dressing etc.,leadupto 50meterandliftupto1.5mcompleteasper direction of Officer-in-charge. 255 Excavating,supplying andfilling oflocal earth (including royalty) by mechanical transport upto a lead of 5km alsoincluding rammingand watering of the earth in layers not exceeding 20 cm in trenches, plinth, 256 Providing & Laying reinforced cement concrete pipe NP3 for Planter 600mm height and 300 mm depth in ground including excavation, protection work, backfilling, concrete and masonary works all complete in direction of engineer in charge. 257 Fabrication , supply and installation of Stainless steel 304 grade canopy around the existing tree guard with laser cut SS -304 grade fins with satin finish and 10mm thick polycarbonate multiwall sheet on roof from sabic plastic products or equivalent complete in all respect along with it aluminum fittings . SS-304 grade tree grate with laser cut design cutout patterns for waterpenetration will be fixed at the center and 18mm thick gang saw cut mirror polished granite/wood plastic composite wooden planks will be fixed ontop of the existing masionary in a curve shape 258 Cement Concrete Planter 259 D & E .( HORTICULTURE AND EXTERNAL ELECTRICAL WORK)-HAZRATGANJ NAJA MARKET ROAD, PLAZA, CHAURAHA, TRILOKNATH ROAD , CAPPER ROAD, DR. SOUJA ROAD, DAYNIDHAN ROAD - PLACEMAKING AND REDEVELOPMENT BILL OF QUANTITY 260 Part G (Horticulture Work) 261 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 262 Supplying and stacking of good earth at site including royalty and carriage upto 20 km lead complete (earth measured in stacks will be reduced by 20% for payment). Analysed Rate. 263 Extra For levelling and neatly dressing of disposed soil completely as per the engineer in charge DSR2023; 2.36 264 Supply and laying of bi axial extruded high modulus polypropylene geo grid conforming to MORTH specifications for base/sub base reinforcement having minimum tensile strength 40 Kn.m IN THE LONGITUDNAL AND TRANSEVERSE DIRESTION, WITH 14 Kn/ M AND 28 Kn/M AND 28 Kn/M TENSILE STRENTGH at 2% and 5 % strain respectively in the longitudnal and transverse direstion, junction eficiency not less than 95% and with 38 mmx 38 mm mesh opening psrLDA Approved 265 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).DSR Horticulture 2020; 2.25 266 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge DSR Horticulture 2020; 2.9 267 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).DSR Horticulture 2020; 2.8 268 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, byspreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).DSR Horticulture 2020; 2.1 269 Rough dressing the trenched ground including breaking clods.DSR Horticulture 2020; 2.6 270 Fine dressing of the ground., DSR Horticulture 2020; 2.7 271 Providing & laying Selection no. 1 doob grass turf with earth 50mm to60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge DSR Horticulture 2020; 2.34 272 Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately): In rows 5 cm apart in both directions DSR Horticulture 2020/ 2.10.1 273 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)Holes 60 cm dia, and 60 cm deep. DSR Horticulture 2020; 2.14.4 274 Holes 45 cm dia, and 45 cm deep., DSR Horticulture 2020; 2.14.5 275 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal ofunserveiceable material’s as per direction of officer in charge (excludingcast of plant & water). DSR Horticulture 2020; 2.57 276 Trees Plant, 2.57.1 277 Shrubs Plant, 2.57.2 278 Hedge Plant, 2.57.3 279 Providing and stacking of Clerodendrum inerme having ht. 25 cm to 30 cm multi branched in 15 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge., DSR Horticulture 2020; 6.7 280 Providing and Displaying Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge., DSR Horticulture 2020; 5.3 281 Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pots of size 20 cm as per direction of the officer-in-charge., DSR Horticulture 2020; 8.30 282 Providing and stacking Jasmine grandiflorum (chameli) of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. DSR Horticulture 2020; 9.8 283 Providing and stacking of Belamcanda chinensis of height 45-60 cm. branched in earthen pots of size 20 cm as per direction of the officer-in-charge. (Lepord lily), PSR LALBATTI 284 Providing and Displaying of Spathiphyllum (peace lily), having 15 cm to 25 cm ht. blooming stag with fresh & healthy foliage well developed in 15 cmof Earthen pot/plastic pot as per direction of officer-in-charge. DSR Horticulture 2020; 3.90 285 Providing and stacking of Syngonium (Butterfly) variegated with 2-3 suckers healthy foliagein Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge., DSR Horticulture 2020; 6.25 286 Shrubs/TREE Plant 287 Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.(DAR 2020 Hort - 8.32) based 288 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12branches and healthy foliage, well formed in cement pots of size 30 cm asper direction of the officer-in-charge. (DAR 2020 Hort - 8.28) based 289 Trees Plant 290 Providing and stacking of Jacaranda mimosifolia of height 10-12 feetin big poly bags of size 18 as per direction of the officer-in-charge.PSR 291 Providing and stacking of Butea frondosa (Flame of Forest) healthy and multi branches of height 4-6 feet in big poly bags of size 18 as per direction of the officer-in-charge.PSR 292 Providing and stacking of Lagerstroemia Flaush (jarool) healthy and multi branches of ht.10-12 feet in Earthen pots of size 12 as per direction of the officer-in-charge. PSR 293 Providing and stacking of Tabebiua (Dolne smith) healthy and multi branches of ht.12-14 feet in Earthen pots of size 18 as per direction of the officer-in-charge. PSR 294 Providing and stacking of Terminalia Mentali healthy and multi branches of height 10-12. in big polybags of size 18 as per direction of the officer-in-charge. PSR 295 Providing and stacking of Plumeria alba healthy and multi branches of height 10-12 feet in big poly bags of size 18 as per direction of the officer-in-charge.PSR 296 Providing and stacking Nicodia of height6-8 feet with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.PSR 297 Providing and stacking Cassia Gluca of height 8-10 feetwith bushy healthy plant in 14 bags & as per direction of the officer-in-charge. PSR 298 Providing and displaying of Phoenix palm plant, having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.PSR 299 Supply and installation ofBamboo of Height 10-12 feet. In all work complete. Market RatePSR 300 (Irrigation) 301 Trenching and Back Filling. Sanctioned Rate. 302 Supply, Installation, laying & commissioning of 90 mm outer dia 6Kg/cm2 HDPE pipe. 33.01 (Jal Nigam Varanasi SOR) 303 Supply, Installation, laying & commissioning of 63 mm outer dia 6Kg/cm2 HDPE pipe. 33.01 (Jal Nigam Varanasi SOR) 304 Supply, Installation, laying & commissioning of HDPE Flange with tail piece, packing & nut bolt complete in all respect. Sanctioned rate 305 Supply, Installation, laying & commissioning Of reducer 90 mm to 63 mm outer dia 6Kg/cm2 HDPE pipe. Sanctioned rate 306 Supply, Installation, laying & commissioning Of ELBOW JOINT 90 DEGREE FOR 90 mm HDPE pipe. Sanctioned rate 307 Supply, Installation, laying & commissioning Of ELBOW JOINT 90 DEGREE FOR 63 mm HDPE pipe. Sanctioned rate 308 Supply, Installation, laying & commissioning Of TEE JOINT90 DEGREE FOR 90 mm HDPE pipe. Sanctioned rate 309 Supply, Installation, laying & commissioning Of TEE JOINT90 DEGREE FOR 63 mm HDPE pipe. Sanctioned rate 310 Supply, Installation, laying & commissioning Offor 63 mm TAIL PIECES. Market Rate 311 Supply, Installation, laying & commissioning of for 90 mm TAIL PIECES HDPE PIPES. Market Rate 312 Supply, Installation, laying & commissioning Of PRESSURE Gauge 2.5 size (Gyceryne). Market Rate 313 3 disc filter. Market Rate 314 2 disc filter. Market Rate 315 Thermos Temperature Controller wuth switch and socket .2 mm cable. Market Rate 316 Butt velding electric heating plate. Market Rate 317 3 CIbutterfly valve. Market Rate 318 2 CIbutterfly valve. Market Rate 319 SPRINKLERS 320 Supply, Installation, laying & commissioning of Service Saddle 3 inch x 1.25 inch. Sanctioned rate with bush 321 Supply, Installation, laying & commissioning of Service Saddle 2 inch x 1.25 inch. Sanctioned rate with bush 322 Supply, Installation, laying & commissioning of Swing Joint for 10 - 12 meter range 360 degree popup. Market Rate 323 Supply, Installation, laying & commissioning of Swing Joint for 3 - 4 meter range 360 degree popup. Market Rate 324 Supply, Installation, laying & commissioning of 25 mm outer dia 6Kg/cm2 CPVC pipe. Market Rate 325 Supply, Installation, laying & commissioning Of Ball Valve for 25 mm pipes. Market Rate 326 Supply, Installation & commissioning of pop sprinkler plastic make material with 3 - 4 meter range 360 degreesMR 327 Supply, Installation & commissioning of pop sprinkler plastic make material with 10- 12meter range 360 degrees. Market Rate 328 Engagement of Plumber for required work etc all complete as per direction of Engineer in charge. PWD SOR 2020-21/Labour Rates Chapter.Rs. 420.00+10%CP 329 Engagement of Labour for required work etc all complete as per direction of Engineer in charge. PWD SOR 2020-21/Labour Rates Chapter.Rs. 335.00+10%CP 330 4 - BORING 331 Boaring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 part I, including collecting sample from different starta, preparing and submitting equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer In charge, up to 150 meter depth below ground level. 300 mm diaAll type of soil (DAR 23.2.1.1 based)Sanction Rate 332 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing (CM) pipe of required dia conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.3.3 333 Supply, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818 including required hire and labour charges, fittings & accessories etc. all complete for all depths as per direction of Engineer in charge. 200 mm nominal size diaDAR No. 23.10.3 334 Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm in the recharge pit, over the existing layer of boulders, in required thickness for all leads & lifts all complete as per direction of Engineer in charge. DAR 23.6 335 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for bore well of: 200 mm dia. DAR No. 23.13.3 336 Providing & Fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS 2800 part - 1 including necessary bolts & nuts of required size complete. 200 mm clamp. DAR No. 23.14.3 337 Supply and fixing of pump set & composite electric panel for submersible kirloskar/ sons/ crompton openwell pumpset greeves make three phases 380-440 v 50 cycles supply with fountain bolts and 3 core 2.5 mm flat PVC flexible copper conductor double insulated submersible cable and 4 core 1.5 mm form fountain pool to fountain electric panel etc fountain pool to fountain electric panel etc. complete with internal wiring lighting system. 338 7.5 HP pump 339 Electric Panel Box 340 Supply and fixing of 3 HP single phase open well submersible pump set of 50 mm x 50 mm pipe size complete with all material, labour T&P etc all as per direction of Engineer in charge. (make kirloskar/ crompton/ KSB 341 Supply and fixing of 2.5 sqmm 3 core PVC insulated PVC shethed flate submersible cable pump with bare bunched copper conductor for submersible pump motor with 1100 volt grade ISI marked all complete as per direction of Engineer in charge.Sanctioned Rate 342 Arrangement of Plumber for 1 year maintenance. PWD SOR 2020-21 343 Horticulture Maintenance 24 months 344 Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, hedge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers (whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide will be provided by the Department & lawn mover and brush cutter with fuel , other T & P material/articles shall be provided by the contractor.) Play grounds / Public parks Per Sqm (as per yard stick 1Mali =2.00Acre).DSR (Hort) 2020/2.40.5 345 Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/ edge bed watering, manureing & apply insecticides & fungicides etc. (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.DSR20202.2.36 346 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 05 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment). DSR 2020 horti - 2.25 347 Supplying and stacking of good earth at site including royalty and carriage upto 15 km complete (earth measured in stacks will be reduced by 20% for payment). Analysed Rate. 348 Supply & stacking Urea 40% Nitrogen @160 kg per acre (as per yard stick of CPWD LDA SOR 2018-19/11.1 349 Supply & stacking DAP 50 kg per acre/year. LDA SOR 2018-19/11.2 350 Supply & Stacking Bone Meal/ Oil Cake(LDA SOR Horti 2018-19/11.3) 50 kg per acre/Year 351 Removal of garden waste by TATA 407 or equivalent including loading and unloading and carriage upto 1 km lead, complete disposal upto designated place as per direction of Officer in charge. DSR Horticulture 2020/2.60 based (Analysis Rate attached) 352 Part H (Electrical) 353 PART (X) 354 FOUNTAIN 355 SITC of Spray comprises of a Calyx Aerating in center flanked with Foam Jets on 4 corners of waterbody.Manifold/Pipework are made from Galvanised steel, B-class, make Jindal, ISI Mark with necessary accessories like flanges, sockets, stands etc. made of steel- galvanized. High quality rubber gaskets, nuts & bolts along with gunmetal control valves to adjust flow pressure.Proper completion of workAs per direction of E/IcFOR A 6 METER DIA WATERBODYPSR (36/G20/CE/23) 356 SITC of In Calyx Aerating Spray, water is sprayed in an inverted cone pattern withasmallcenterjet.Calyxnozzlemadeofaluminiumalloy– epoxycoated/StainlessSteel,centerjetnozzlemadeofbrass– chromeplated.Approx.heightofwatereffects:Calyx–1.25m heightX4.5mdia,CenterJet–3mheight. Proper completion of workAs per direction of E/Ic,FOR A 6 METER DIA WATERBODYPSR (36/G20/CE/23) 357 SITC of Foam jet nozzle, on ball joint, of1.25” orifice size. Nozzle made ofBrass- Chrome plated. Approx. height of water effects: 1.2m. Proper completion of workAs per direction of E/Ic, FOR A 6 METER DIA WATERBODYPSR (36/G20/CE/23) 358 Supply,Installation,TestingandCommissioningofLuminaries comprise of 12V LED lights (RGB). Complete light body made of Stainless steel 304 grade, total 27watt power leds. Toughened glass with seal.Stainless steel 304 grade cable gland. All external nuts and bolts are of Stainless steel 304 grade. Adjustable mounting bracket is made of Stainless steel 304 grade. IP 68 compliant. All in pool connections shall be fully waterproof. Make of Luminaries As per direction of E/Ic,FOR A 6 METER DIA WATERBODYPSR 359 SITCofMonoblocktypesubmersiblepumpset whit stainer/ filter ofFollowing Capacity(Threephase,50Hz,415-380VAC)propercompletion ofworkasperdirectionofE/Ic. Kirloskar/Crompton Greaves/KSB/Texmo. Suction filter for pump: Filter body & filter mesh made from AISI 304 standard stainless steel. As per direction of E/Ic 360 3 HP PSR 361 SITC of 1.1 kV grade double insulated copper flexible cable 2.5 sq.mm x 3 core for pumps,As per direction of E/IcPSR 362 SITC of 1.1 kV grade double insulated copper flexible cable 1.5 sq.mm x 4 core for lights, As per direction of E/Ic PSR 363 PSR Supply, Installation, Testing and commissioning of specialised Outdoor type Electric panel for fountain which include control arrangement for fountain, pumpset andRGB Sequencing lighting comprises of :1. Contactor 25 Amp- 01 Nos (Make: L&T/ Schneider/ Siemens/ GE)2. DOL Starter - 01 Nos (Make: L&T/ Schneider/ Siemens/ GE)3. Single Phase Preventer- 01 Nos (Make: Bentex/ Selec/ GIC or equivalent)4. Incomer Main Switch 20 Amp- 01 Nos (Make: L&T/ Schneider/ Siemens/ GE)5. Overload Relay 6-12 Amp- 01 Nos (Make: L&T/ Schneider/ ABB/ BCH or equivalent)6. Fuse for motor 32 Amp- 03 Nos (Make: GE/ L&T or equivalent)7. MCB for Lights 6 Amp -01 Nos (Plaza/ Anchor/ ABB/ Havells/ Legrand or equivalent)8. Push Button On/ Off switches (Red/ Green)- 02 Nos. 9. Overload Indicator - 01 Nos (Make: Eaton/ Siemen or equivalent)10. Single Phase Indicator- 01 Nos (Make: Eaton/ Siemen or equivalent)11. 3 Phase indicator RGB- 01 Nos (Make: Eaton/ Siemen or equivalent)12.Voltmeter- 01 Nos. (Make: Motwane, Innova, Fluke or equivalent)13. Ampere Meter- 01 Nos (Make: Motwane, Innova, Fluke or equivalent)14. SMPS/ Transformer for lights- 01 Nos (Make: Meanwell/ Pheonix/ Omron or equivalent)15. RGB Lights controller- 01 Nos. (Make: Wet Design/Fontana/A.M. Irrigation System/Bharat engineers)16. Internal Wiringsteel sheet 16 gauge paint finish enclosure with hinged front door with provision for incoming & outgoing cable entry. Outgoing ampere 10, size of panel - 3ft X 2ft X 1ft depth.As per direction of E/Ic PSR (36/G20/CE/23) 364 Supply of 4000mm Extruded Square aluminum pole (grade 6063) Sq. 150 x 3mm thickness with IP68 Connector.Bespoke laser cutting design of length 1400mm with 50W In-Built LED with controlled downward light emission options (customized) with SS fasteners, Pre treated epdm black gaskets. Die-cast aluminum mounting plate Sq.250 x 12mm thick with 4 elongated holes 38 x 19 to suit M16 bolts at PCD 180 with pure polyester powder coating. Fixed with Hot dip galvanized foundation bolt. Mechanical resistance should be minimum IK06. The Pole should be undergone pure polyester powder coating process & Acid treatment to ensure high corrosion resistance. On the top of the pole there will be built-in Spot Lights of 2 x 18W LED are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, power factor >0.9, THD <10%, Inbuilt Surge protection 6KV. Optical grade clear toughened glass diffuser of 4mm thickness with controlled downward light emission. Colour Temperature LED 3000K, 230-240Vac, CRI >80, MacAdam step 3. The driver should be inbuilt in the pole itself and maintenance can be done from the junction box itself. PDC aluminum service door 348mm height x 110mm width shall be provided with the company logo embossed on the bottom of the door and safety rope. The control gear tray is prewired with 2.5 Sq.mm cable,6A MCB and 32A terminal connectors for loop-in / loop-out arrangement. Any other internal cables and connections shall not be covered in the scope of supply. The manufacturer should have Inhouse NABL accredited lab to check and provide correct photometry of the product. The make should be as per K-Lite Verbena Spot KL-4583/Wipro/Ligman 365 Supply and fixing of 3500mmsteel poles are made out of mild steel galvanized rebbed extrusion profile having bottom section dia125mm and upper section dia 81mm with cast iron embellishment e8The pole have a service window at bottom section wih heavy duty four way connector and a mcb. Mild steal base plate with four nos. mounting holes is fixed and welded with bottom section . pole is primer coated and polyurethene painted . POLES BPTH SIDE OF THE ROADS AT 10 METER CC DISTANCE. PSR - BEGUM HAZRAT MAHAL PARK 366 Supply and fixing of OVER 600mm long aluminium dia cast body post top is mounted at the top with polycarbonate diffuser and fitted with 40w led disc bis registered make philips , bajaj, twinkle, lustore, K LITEor equivalent repuateted make Quotation rates 367 S/E of G.I. wire on 8 to 4 SWG on pole/service bracket including binding etc. complete in all respects SI.No. 628/18. 368 S/W of submain with two Nos. of 2.5 Sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing conduit complete with supply of all material Labour and T&P required for proper completion of the work as directed at site by E/I. SI. No. 289/18. 369 S/Fof40ATPNofAutomaticstreetlightcubiclecontrolpanelpaintedwithanti corrosivealkaliandacidproofpaintconsistingoftimeswitchTSO100serieswith contractors,HRCfuses,isolatingswitchmeteringinstrument& instrumentbox with CTs etc, in case of TPN, complete in all respect as per direction of Engineer-in-charge. SI. No. 807/18 e(ii). 370 S/L of following cable Al conductor P.V.C. insulated armoured served sheathed cable 1100V grade at a depth of 750mm. Below ground level over a cushion of 75mm with DWC Pipeapproved makeUPPPCL as per direction of E/I. complete in all respects. 501/2018. Approved Makes:- Gloster/ Polycab/ KEI/ SCI/ Havells PWD SOR 501 371 10 sq. mm 4 core 372 (a) 35 Sq.mm 3.5Core 373 (b) 16 Sq.mm 4 Core 374 (c) 70 Sq.mm 3.5 core 375 S/F of following size palm or pin type copper tin plated cable socket (Lug) to the cable leadinsulatingwithtapeandmakingconnectionscompleteinallrespectsasper direction of E/I.SI.No.504/SOR-18. 376 10 sq. mm 4 core 377 (a) 25 sq.mm. 378 (b) 50 sq.mm 379 (c) 16 sq.mm 380 S/B of earth rod 20mm dia into 2.5mtr long including G.I. wire 7/16 SWG to connect earth rod to earth clamp on pole 3.00 mtr long steel conduit to carry earth wire along the pole. A.R. Bond No.87/CE/EE(E/M)2021, Dated 09-11-2021 381 S/Fof6Ampto32Amp.SPMCB(10KA)Ccurvecompleteinallrespectasper direction of Engineer-in-charge. SI No. 1002/18. CAT-A. 382 Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountendon non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc.The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. ( Incoming 200 Amp. TPN-1 No Outgoing 100 Amp. TNP-2 Nos. Cat. B. Cubicle TypePWD SI No : 802 (a) 383 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swgand inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PWD SI No :725 (A) 384 Supply and Laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. DSR E&M 2022/14.161 385 Supply, Installation, testing & commissioning of Servo Stabilizerwith Isolation transformer 100KVA,3-phase servo voltage stabilizer with isolation transformer , oil cooled, Input 300-470 VAC, 4 Wire, 50 Hz, output: 400+/-1% with oil,suitable for UNBALANCED LOAD with automatic operation (outdoor type-IP 64).The stabilizer shall comply with the following requirement:: Regulation : +/- 10 %.: Over load & Short circuit protection.: Protection cut-off against Over/Under Voltage.: Single phase protection.: 3 nos. phase indication lamps. 386 PLINTH AREA RATES CPWD 2023, Supply installation , testing and commissioning of IP based CCTV system for building security comprising of PTZ/FIXED CAMERA, CABLING , RECORDING , DISPLAY SYSTEM HARDWARE SOFTWARE SUPPORT,FOR EXTERNAL SURVILLANCE 6.10.2 , FOR PLAZA AREA ONLY 387 Operation and maintenance for 1 years 388 PART (Y) 389 LFkkfir dh x;h ykbZVksa ds vuqj{k.k ,oa lapkyu dk dk;ZA 390 Providing of Trained Electricion With Tool Kit (As per PWD SOR/2020-202. For 18 months after DLP 391 Providing ofHelper Technicion (As per PWD SOR/2020-2021.For 18 months after DLP 392 PART-Z 393 H.T./L.T. work 394 S/Fofdoublepolestructurewith2nosS.T.poleforS/S 410SP-55 11 Mtr. longin1:3:6CC foundation 1/6 of pole length below G.I. and 30cm above G.I. 20cm thick around the pole with 2 nos. channel 125mmx75 mm one No. Chennel cross arm of 75mmX 40mm 2 No. 50X50X6mm sngle iron bracings with necessary nut bolts & packing pieces complete with painting as per direction of E/I.(PSR Bond No. 490/CE/2024) 395 S/F of 11 KV Pin insulator with G.I. Bolt /spindle nut etc. complete in all respects. (PSR Bond No. 490/CE/2024) 396 S/Fof11KVDiscinsulatorincludinggunfittingoncrossarm/clampsfixedonpole complete in all respects. (PSR Bond No. 490/CE/2024) 397 S/E of over head line with A.C.S.R. conductor on pole/service bracket including binding etc. complete in all respects. S.I.No-627/18. Racoon/Dog(PSR Bond No. 490/CE/2024) 398 S/F of M.S. Channel 75mmX40mm Vshape crossd arm for two No. pin insulator proper completion of work. (PSR Bond No. 490/CE/2024) 399 S/E of 11 K.V L.A. set of 3 wire. suitable for mounting on steel support complete in all respect as perdirection of E/I.(PSR Bond No. 490/CE/2024) 400 S/Eof11K.V.T.P.M.O.switchonpoleincludinghandlerodetc.completeinall respects as per direction of E/Ich.(PSR Bond No. 490/CE/2024) 401 S/E of 11 K.V. D.O. fuse set on pole complete in all respect as per direction of E/I.(PSR Bond No. 490/CE/2024) 402 Supply and laying of70 Sqmm 3 core 11 KV standered aluminium conductor XLPE(Cross linked polyethylene)insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connectedwith earth conductor by clamps etc. PWD SOR No : 506 (d) (PSR Bond No. 490/CE/2024) 403 S/F of 70 Sq.mm size 3 core XLPE 11 KV outdoor type jointing kitproper completion of work as per direction of E/I A.R. Make: Raycheme, Mahindra. (PSR Bond No. 490/CE/2024) 404 S/F of level 2 following capacity 11/0.433 K.V. Al’ wound conventional 50Hz 3 phase oil immersed naturally cooled distribution T/F confirming and with amendments there of, havinglosses as per BEE standered with all standard fittings, including first filling of oil complete in all respects, of make UPPCL/KESCO Approved (PSR Bond No. 490/CE/2024)(a) 63 KVA (A.R.) 405 Supply and burring of Safe Earthing Electrode T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip will be extra)Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.S.I.No-726 B/18. 406 S/Lof25mmx3mmGIstripfromearthelectrodedirectlyinthegroundasrequired complete in all respect Item No 716 SOR-2018 407 Supply and fixing of 2 metres high cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x 6mm angle iron frame having vertical members spaced at 1 to 1.25 mts and horizontal members spaced at 1 mt. The vertical members shall be grouted in floor and horizontal members in the wall to a depth of 300mm with ends forked. The cage shall have 2000mm x 1000mm size one leaf door with locking device having door frame fabricated with 35mm x 35mm x 6mm angle iron and 3mm expanded metal duly fixed with the cage member with hinges etc. The cage shall be painted with red oxide primer and synthetic enamel paint. The job includes all materials, labour, T&P etc. for proper completion ofwork. PWD SI No : 1142 408 S/L of followingsize G.I.B classpipe ata depthof 750mmbelow groundlevel as cable carrier as direction of E/Inch. (PSR Bond - 490/CE/2024)(a) 80 mm dia
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
Uttar Pradesh View Result →
16.
Public Administrative Department #9460897 Technical Bid
Tender for construction work of Kalyan Mundap at Khasra No. 55, Daud Nagar, Faizullaganj, Lucknow., 1 Shelter House (Part - A) 2 Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 3 Constuction of subgrade with material obtained from avaliable land (for local earth work) Construction of embankment with approved material obtained from avaliable land as pormited and approved by engineer-in-chage and as per technical specification clause 301.3.4.1 with all lifts and leads, spreading grading to required slope and compacting to meet requiredment of table 300.0 and 300.2 as per technical specification clause 301.5 with centre up to 15 km.(by Analysis) 4 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 em deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 7 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion@ 7.51itres I sqm ofthe vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 10 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 11 Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 12 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. 13 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 14 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 15 Centering and shuttering including strutting, propping etc. and removal of form for staircases (including landing) 16 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5000 or more. 17 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum (M-25 up to plinth level) 18 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum(M-25 above plinth level) 19 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 20 Brick work with common burnt clay (non modular) bricks of class -150in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 21 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 22 Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) 23 Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 24 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm 25 Providing and Fixing Ist quality ceramic glazed wall tiles conforming to IS :15622 (thickness to be specified by the manufacturer), of approved make in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm , including pointing in white cement mixed with pigments of matching shade complete. 26 Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge. 27 Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mm square hollow box section including applying a priming coat of approved steel primer, placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge. (Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SS screws shall be paid separately. 28 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 29 Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) 30 Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R4 series with frame (64 mm & above) x (55 mm & above) & sash (64 mm & above) x (100 mm & above) & French (False) mullion (64 mm & above) x (60 mm & above). (Height above 2.5 metre). 31 Fixed window I ventilator without mullion I transom. Using R 1 series with frame (33 mm & above) x (35 mm & above). (Height upto 0.90 metre) (UPVC Window) 32 Casement window double panels with fixed mullion with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R2 series with frame (39 mm & above) x (39 mm & above) & sash (39 mm & above) x (60 mm & above) & mullion (39 mm & above) x (60 mm & above). (Height upto 1.2 metre). (UPVC Window) 33 Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above). (Height above 1.8 metre) (UPVC Window) 34 Providing and fixing lSI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including lSI marked Stainless Steel butt hinges with necessary screws 35 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 36 Providing and fixing ISI marked Stainless Steel sliding door bolts with nuts and screws etc. complete. 250x16mm 37 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10mm 38 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100mm 39 Providing and fixing aluminium hanging floor door stopper, lSI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper 40 Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). 41 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1 .4 mm wide aperture with matching wood beading 42 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 43 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 44 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 45 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10x 160 mm 46 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). 47 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in allcolours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. Thetiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm 48 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 49 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 50 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 51 Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : 52 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 53 6 mm cement plaster to ceiling of mix : 1:3 (1 Cement : 3 fine sand) 54 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 55 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 56 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 57 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats 58 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 59 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board. 60 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(c) The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixedslurry. 61 Supplying and Stacking Filling sunken floor with over burntjhama brick aggregate 120mm to 40mmincluding compacting of materials complete as specified and directed for all levels. 62 Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm 63 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm 64 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2845 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement 5 coarse sand) admixed with water proofing compound conforming to IS: 2845 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs (c) After two days of proper curing applying a second coat of cernent slurry using 2.75 kg/ sam of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1) cement 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth With average thickness of 120 mm and minimum thickness at khurra as 65 mm 65 FIRE FIGHTING (PART - B) 66 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) 67 (a)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 68 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. 69 (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. 70 (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 71 450 lpm at 35 m Head 72 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 73 Air Release Valve, Gunmetal, having rubber ball with 1” (25mm) BSP Male threaded inlet 74 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 75 Providing, laying,of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia 76 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia 77 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia 78 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 79 INTERNAL HYDRANT 80 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal 81 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal 82 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 83 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required Gun metal: 84 Fireman Axe-made of carbon steel with rubber insulated handle tested to 20,000 Volts as per IS:926 Make: NEWAGE 85 Fire shaft door fabricated out of M.S. sheet and frame, door size of 1200 (W) x 2100 (h)with 4 mm thick glass, suitable Rubber beading and Locking arrangement and complete door shall be powder coated with red color powder coating 86 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe 87 SUBHEAD-II :FIRE EXTINGUSHER 88 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: Co2 type Fire Extinguisher 4.5 Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and wheel type valve with initial Charge as per IS: 15683:2018 specification, bearing ISI Mark & EIL approved. Make: SAFEX Capacity 4.5KG 89 Providing and fixing of ABC Power type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket. Conforming to IS: 15683 finished externally with red enamel paint fixed to wall with brackets complete with internal charge. Capacity 6KG 90 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 91 SUBHEAD-III : FIRE CONTROL PANELS 92 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panelMCCBs (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. Same as above item but following mountings. INCOMER:- 1 Nos. 100 Amps. 4P MCCB ( 35 KA) 1 Set phase indication lights (R, Y, B) 1 No. Volt Meter (digital type) with inbuilt VSS & control fuses.1 No. 0-100 Amp. Ammeter (digital type) with inbuilt ASSBUS BARS: 150 Amps. TP&N aluminium bus bars OUT GOINGS:-2 Nos.25 Amps. TPN MCB (10 KA) 93 Copper Power Cables, Solid Copper Conductor upto 6 sq. mm & Balance Stranded Copper, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Unarmoured/Armoured (Glavanised wire for cables up to 10x1.5 sq. mm, 8x2.5 sq. mm, 2x10 sq. mm, 3x10 sq. mm, 4x6 sq. mm & balance all galvanised steel strip), Extruded PVC Type ST2 Outer Sheathed, 650/1100 V Grade as per IS 7098 4 Core X 10 sqmm. Aluminium Armoured 94 Supplying and making end termination with brass double compression gland and aluminium lugs for following size of XLPE insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 4 Core X 10 sqmm. Aluminium Armoured 95 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 96 6 C x 2.5 Sqmm 97 2 C x 2.5 Sqmm 98 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 99 25 mm Conduit 100 32 mm Conduit 101 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness. 102 INTERNAL, EXTERNAL PLUMBING WORKS & DRAIN (Part - C) 103 SANITARY INSTALLATIONS & C.P FITTINGS 104 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 105 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 106 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 107 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge 108 Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade 109 Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore 110 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge. 111 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 a) (15 mm nominal bore 112 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 113 Providing and fixing toilet paper holder : C.P. brass 114 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (For bath) .15 mm nominal bore 115 Providing and fixing C.P. brass shower rose with 15 or 20mm inlet : 150 mm diameter 116 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS: 8931. 15 mm nominal bore 117 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 118 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms 119 Upvc WASTE & VENT PIPES AND FITTINGS 120 Providing and fixing in floor and wall face Ringfit SWR PVC Conventional system for soil and waste water pipes conforming toType B including jointing with seal ring. (i) Double socketed pipes. 121 110mm dia SWR P.V.C. pipe 122 90mm dia SWR P.V.C. pipe 123 Cutting holes up to 15x15 cm in R.C.C. floors androofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof 124 Providing and fixingcPVC pipes complete with cPVCfittings and clamps, including cutting and making good walls etc. ( for wash basin waste ) 32mm dia nominal bore 125 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc.(a) for 100mm dia pipe. 126 Providing & fixingUPVC Coupler 127 a) 110 mm dia. 128 b)90 mm dia. 129 Providing and fixing trap of self cleansing design with screwed down or hinged grating with hopper complete, including cost of cutting and making good the walls and floors : (a) 100mm inlet & 90mm outlet. 130 Providing and fixin SWR PVC. 90° elbow withincluding fittings complete. 131 a) 110mm 132 b) 90mm 133 Providing and fixing 45° elbow withincluding fittings complete. 134 a) 110mm 135 b) 90mm 136 Providing and fixing SWR PVC T Band with access doorincluding fittings complete. 137 110x110x110mm 138 90x90x90mm 139 Providing and fixing SWR PVC Y including fittings complete. 140 110x110x110mm 141 90x90x90mm 142 Providing and fixing END CAP withincluding fittings complete. 143 a) 110mm 144 b) 90mm 145 Providing and fixingcast iron terminal guard. 146 110 mm 147 INTERNAL RAIN WATER DRAINAGE WORK 148 Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110 mm dia(SW pipe) 149 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm 150 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. 151 Coupler 110 mm 152 Bend 87.5 degree 110 mm Bend 153 Shoe (Plain) 110 mm Shoe 154 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 155 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 156 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 157 INTERNALWATER SUPPLY WORKS 158 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 159 20mm dia nominal outer dia pipes 160 25mm dia nominal outer dia pipes 161 32mm dia nominal outer dia pipes 162 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge..Internal work & external 163 20mm dianominal bore 164 25mm dianominal bore 165 32mm dia nominal bore 166 40mm dia nominal bore 167 Providing and fixing gun metal gate valve with wheel of approved quality. 168 20mm dia nominal bore 169 25mm dia nominal bore 170 32mm dia nominal bore 171 40mm dia nominal bore 172 EXTERNALSEWERAGE & RAIN WATERSYSTEM 173 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. 174 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter 175 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 100mm dia SW pipe 176 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design : 150 mm.dia. RCCPipes 177 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 150 mm.dia. RCCPipes 178 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 179 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 180 Extra for depth for manholes:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 181 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 182 EXTERNAL DRAIN 183 Earthworkinsurfaceexcavationnotexceeding30 cm indepth but exceeding 1.5m in width as well as 10 sq.m. on plan including getting out and disposal of excavated earth upto 50m and lift upto 1.5m, as directed by Engineer-in-Charge:All kind od soil. 0.30 m & Above 184 Providing and laying in posotion cement concrete of specifiedgrade excluding the cost of centering and shuttering - All workup to plinth level. 1:5:10 ( 1 cement : 5 coarse sand {zone-III} : 10 graded stone aggregate 40mm nominal size) 185 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 186 Mild steel or iron work in plain work such as in R.C.C. or R.B. (when not included in an over all rates ) including bending for proper completion of the workand including supply of steel and its wastage , bends, hooks and authorised overlaps shall be measured up to floor two level. 187 Centering and shuttering including strutting, propping etc. and removal of form for foundation footing bases bo column etc for mass concrete etc. for mass concrete. 188 BORE WELL 189 External W/S arrangements with T.W. boring of 150 mm dia with 110 mm dia P.V.C. pipe assembly, 1.5 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangements etc . 190 6 PVC casing pipe of ISI mark. 191 P/ F 2 GI pipe (B) class. 192 Nylon mesh for filter. 193 Plastic dori. 194 Solvent cement. 195 6 End cap. 196 6 Submersible cap. 197 2 MS clamp (Heavy). 198 2 GI elbow. 199 2: X 6 GI nipple. 200 1.5 HP 9 Stage submersible pump of ISI mark with automatic panel. 201 2.5 sqm. Submersible cable. 202 Drilling charges for 6 dia tubewell. 203 Pea Gravel. 204 2 MS socket. 205 Cartage of material upto site. 206 INTERNAL ELECTRIFICATION WORK (Part - D) 207 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B 208 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 209 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 210 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 211 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 212 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 213 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 214 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 215 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 216 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 217 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 218 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 219 20 mm 220 25 mm 221 32 mm 222 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 223 Supplying and fixing brass batten/ angle holder including connection etc. as required. 224 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 225 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. 1 or 2 Module (75mmX75mm) 226 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 227 Telephone socket outlet 228 TV antenna socket outlet 229 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 1Pair 230 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 231 Supplying and drawingCo axial TV cable, RG-6 grade, 0.7 mm solid copper conductor, shieldedwith fine tinned copper braid and protected with PVCsheathin the existing surface/recessed steel/PVC conduit as required. 232 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 100 mm dia 233 Lighting Fixtures (Lights/Fans) : 234 Supply, Installation, Testing and commissioning of 1200 mm sweep BEE 5 star rated, ceilingfan with Brush Less Direct Current(BLDC) motor class of insulation:B, 3 nos blades, 30 cm long down rod, 2nos canopies shackle kit safety rope copper winding, Power factor not less than 0.9, service valur minimum 6.00, Air delivery min 210 Cum/Min, 350 RPM THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts washers, temperature rise =75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz single phase AC supply, earthing etc complete as required (i) BEE 5 Star rated-1200 mm sweep 235 Armoured Cables (Cable/Gland/Lug) : 236 Supplying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 237 size 10 sq mm x 2 core 238 size 10 sq mm x 4 core 239 size 16 sq mm x 4 core 240 size 35 sq mm x 3-1/2core 241 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm 242 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. 243 Upto 35 sq. mm 244 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 245 Upto 35 sq. mm 246 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 247 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 248 2 X 10 sq. mm (19mm) 249 4 X 10 sq. mm (25mm) 250 4 X 16 sq. mm (28mm) 251 3½ X 25 sq. mm (28mm) 252 3½ X 35 sq. mm (32mm) 253 Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm 254 Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm 255 Earthing Work : 256 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 257 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 258 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 259 L.T. Switch Panel Board : DBs & MCBs : 260 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 261 Single pole 262 Triple pole and neutral 263 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 264 40 A 265 63 A 266 Supplying and fixing following way, surface/recess mounting vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link , earth bar, din bar for mounting MCBS but without MCBs and incomer as required 8 way(4+24) , Double door 267 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 268 8 way (4 + 24), Double door 269 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 270 Miscellaneous Items : 271 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 272 Supply and Fixing of shock treatment chart.prescribedas per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work. 273 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 274 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 275 Non-Schedule Items 276 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 277 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 278 CCTV WORK (Part - E) 279 SITC of 2 MP Dome Camera, 1/2.8 Progressive CMOS, ICR, 1920x1080: 25fps(P) / 30fps(N), H.265+/ H265/ H.264+ & H.264, 3D DNR, BLC, IR range: up to 30m, DC12V & PoE, Support mobile monitoring 280 SITC of 2 MP Bullet Camera 1/2.8 Progressive CMOS, ICR, 1920x1080: 25fps(P) / 30fps(N), 2.8mm/F2.0 lens (4/6mm optional), H.265+/H265/H.264+ & H.264, IP67, DWDR, 3D DNR, BLC, IR range: up to 30m, DC12V & PoE,Support mobile monitoring 281 Supply, Installation, Testing & Commissioning of 24Channel Network Video Recorder with specifications as follow: Supported Image Format H.264+/H.264, H.265+/H.265, MPEG-4, JPEG, M-JPEG; Supported Image Resolution 1920x1080, 1,280 x 960, 960 x 720, 640 x 480, 320 x 240; Maximum Number of Cameras 32; RAID 5, 320MBps incoming bandwidth Camera Control Pan/Tilt, Zoom, Focus, Brightness, Preset position call and program (up to 256), Auto mode GUI REC/Playback Control REC, PLAY, Rev PLAY, Pause; Network Interface Camera port: 10Base-T / 100Base-TX Min 2x 8TB can be installed. Certification: UL, CE, BIS, FCC. 282 24 Port POE Switch ,Unmanaged PoE, 24 100M PoE, 1 1000M PoE, 1 1000M SFP, 250m Transmission, 6KV Surge Protection, 225W 283 SITC of 2U Rack with complete accessories. 284 Supply , Installtion , Testing and Comissioning of CAT6Apatch cord 3 feet for rack side switch to jack panel connectivity. Approved Makes:Belden/Siemon/Panduit/Derwiser/ Rit 285 SITC of 8 TB Survillance Hard Disk 286 Supply and laying of CAT 6 UTP cable 287 Supply and laying of 25mm dia PVC conduit including accessories. 288 SITC of 49 flat screen FHD professional LED suitable for 24x7 operation with remote control and wall mount unit/floor stand complete with making connection etc as per list of approved makes. 289 STREET POLE WITH LED LAMP & HIGH MAST (Part - F) 290 Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single Arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. 291 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 80 Watt. Confirming to IP 66 Protection complete in all respect. 292 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 293 Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.3 output (1output per phase) and suitable for three phase supply 294 Supply & fixing of anticlimbing device fabricated from G.I.(flat) of 25 mm x 6mm size in a shape of ring of the pole size, having G.I. flat pointed fins of length 225 mm in 8 nos. including all the materials, labour, T&P and other material required for proper completion for work and to the satisfaction of Engineer-in-Charge. 295 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect. CAT. - AAA 296 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size 297 size 6 sq mm x 3 core 298 size 10 sq mm x 4 core 299 size 25 sq mm x 3-1/2core 300 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed, underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable 301 size 6 sq mm x 3 core 302 size 10 sq mm x 4 core 303 size 25 sq mm x 3-1/2core 304 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 305 size 6 sq mm 306 size 10 sq mm 307 size 25 sq mm 308 Earthing Work : 309 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required 310 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required 311 D.G. SET 30 KVA (Part - G) 312 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping.Supplying, installation, testing and commissioning of Silent Type DG Sets,AMF Panel, Bus Ducting/ Cables from DG Sets to Essential Panel, Synchronizing Panel where required, DG Set enclosure room sound insulation/ventilation/smoke exhaust as required, Earthing of DG Set system, control cabling, Fuel tank/piping, DG set Exhaust piping/Exhaust Chimney as per CPCB norms, Civil works connected with DG Sets including Foundation as required. DG Set Compatible for synchronising Panel30 KVA 313 Supply and fixing of M.S. Fencing frame duly fabricated from M.S. angle iron 50mm x 50mm x 5mm /40mm x 40mm x 5mm with M.S. flat 40 x 6 mm with M.S. welded 10 SWG, Mesh Jali best quality 25 x 25 mm on fencing frame with 6 Nos. M.S. Fasteners of required size duly painted complete in all respects. The Fencing frame of different sizes as site requirement. 314 Add Extra For RCC Foundation Work for D.G. Set Including Cost of Exaust Pipe with Structure and Other Misc. Work and T&P etc. Complete in all respect as per directed by Engineer In-Charge. 315 Earthing System : 316 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 317 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 318 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as requiredide. 319 Boundary Wall & Entrance Gate (Part - H) 320 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lifts up to 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50 m. - in ordinary soil . 321 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 322 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 323 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 324 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 325 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum (M-25 up to plith level) 326 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:N Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% ofthe specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum (M-25 above plinth level) 327 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5000 ormore. 328 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1 :6 (1 cement : 6 coarse sand) 329 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 Cement : 6 coarse sand) 330 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm). 331 Making Groove in plaster 10 to 12 mm wide x 8mm deep in plaster vertically or horizontally as required . 332 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 333 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 334 Interlocking Tiles (Part - I) 335 Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per technical specification clause-401 336 Providing and Laying of interlocking concrete Block pavement having thicking 80 mm as per drawing and technical specification Clause 1504. (Exclusive G.S.B.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 6
Uttar Pradesh View Result →
17.
Defence #9439265 AOC
Tender For Conversion Of Oh Line To Ug Cables With Connceted Items At Namkum, Khojatoli Pocket And Lph Area Under Ge Ranchi; 2 Item No 01 : Dismantling & taking steel pole/struts complete and removal from site complete all as specified 3 Item No 02 :Dismantling & taking down ACSR/AAC conductor of any size from HT/LT over head line and removing from site complete. 4 Item No 03 : Dismantling & taking down shackle/pin insulators of any size and type complete and removal from site complete. 5 Item No 04 Dismantling & taking down cross arm, channel, angles, flat ironvarious size/shape incl nut, bolt and washers etc complete and removal from site complete. 6 Item No 05 : Dismantling & taking down GI guard wire of any size from HT/LT over head line and removing from site complete. 7 Item No 06 :Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11KV,EARTH system cross sectional area3 core 95 sq mm laid in trenches or passing through pipe or fixed to wall /pole complete 8 Item No 07 : Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in hard /dense soil all as directed. 9 Item No 08 : Excavating in trenches not exceeding 1.5m wide and exceeding 1.5m inbut not exceeding 3.0m depth for laying of cable, foundation etc, and getting out in hard /dense soil all as directed. 10 Item No 09 : Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25cm all as directed. 11 Item No 10 : Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed. 12 Item No 11 : Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed.(Note: Thickness after punning shall be measured for payment ) all as specified and directed. 13 Item No 12 : Supplying & laying reinforced precast concrete cable cover, class HV,Type 1, flat, size 300 mm x 180 mm x 40 mm abetting Each other with gap between adjacent slab not exceeding10mm over under cable for protection all as specified and directed. 14 Item No 13 : Material and labour for cutting of metallic road/ hard standing/hard rock/wall up to a size not exceeding 20cm widthand not exceeding 60cm in depth for laying ofprotection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm grade crushed stone aggregate upto existing surface level or removing the any type of tiles carefully and refixing properly as per existing surface including suitable size of GI pipe (if necessary)complete all as specified and as directed by Engineer-in-charge.Note: 1. If damaged/broken the any type of tiles while removing, the contractor shall replace the broken tiles with new one.2. The Quoted rate is included for all materials/T&P/Machinery used in this item, no material can paid/measured separately.3. All the removable tiles/re fixable material shall kept carefully at a safe place for refixing with in this quoted rate.4. GI Pipe shall measured and paid separately under relevant item. 15 Item No 14 :M& L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure not less than one meter below ground level for passing/ laying of HT cable complete. 16 Item No 15 : Supply and fix cable jointing kit for 11 KV grade (earthed) cable for outdoor termination , cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm all as specified and directed. 17 Item No 16 : Supply and fix cable jointing kit for 11 KV grade (earthed) cable for indoor termination , cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm all as specified and directed. 18 Item No 17 : Supply and fix cable jointing kit straight through for 11 KV grade (earthed) cable for outdoor termination , cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm all as specified and directed. 19 Item No 18 :M&L for Plain cement concrete 1:4:8 type D2 using 40mm grade stone aggregate as in foundations, filling and mass concrete all as specified and directed. Note - Rates including the forming for shape to PCC as required all as specified and directed. 20 Item No 19 : Material and labour for Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in foundation, plinth courses, string courses, lacing courses, parapets with fair surface complete all as specified.Note - Rates including the forming for shape to PCC as required all as specified and directed. 21 Item No 20 : M & L for Erection in vertical position steel tubular sewage pole (ISI market) with cast iron base plate, final taper plug, bolts, nuts & screws etc, type410-SP-55 (11 Mtr long) confirming to IS 2713 part 1 to 3) 1980 including two coats of black bituminous paint throughout internally and externally upto planting depth and two coats of synthetic enamel paint of alternate black and red strips, 30 cm high over one coat of red oxide primer upto 1.5m height from ground level/coping. The remaining portion shall be painted with two coats of aluminium paint over coat of red oxide primer complete all as specified and directed. Note : Necessary earthwork, PCC shall be measured and paid for separately.. 22 Item No 21 : S & F pin type porcelain vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvinised iron washers and one galvanised iron nut , 150 mm height 150mm dia for 11000 volts grade all as specified and as directed. 23 Item No 22 : Material and labour forexpulsion / drop out / horn gap type fuse carrier assemblyoutdoor type 200Amps capacity above 25 Amps & upto 50Amps includinginsulator andfuse element conforming to IS specifications suitable for 11000 volts (HT) all as specified. 24 Item No 23 : M & L for cross arms. Bracings supports, clamps and back plates fabricated from structural steel sections including nuts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic paint all as directed. 25 Item No 24 : M & L for Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured all as directed.Note - MS Clamp for fixing if device to be measured separately in respective item. 26 Item No 25 : S & F Lightning arrester suitable for 11 KV, expulsion type, confirming to IS- 3070 part-I of 1985 complete with all fittings transmission class, discharge capacity of 65 KA compplete all as specified and directed. 27 Item No 26 : Supply and fix HT 11KV outdoor type Gang operated air break switch of rating upto 200 amps, vertical mounted fixed complete with 9 insulators including , operating rod of 25mm dia medium garde GI tubing of suitable length, operating handle with locking arrangement fixed to pole with suitable size of MS clamps to be operated from ground level, provn of insulated connected leads of connections with required accessories complete all as specified and directed 28 Item No 27 : Supply and fix HT 11KV outdoor type Gang operated air break switch of rating upto 400 amps, vertical mounted fixed complete with 9 insulators including , operating rod of 25mm dia medium garde GI tubing of suitable length, operating handle with locking arrangement fixed to pole with suitable size of MS clamps to be operated from ground level, provn of insulated connected leads of connections with required accessories complete all as specified and directed 29 Item No 28 : M & L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts for HT, 25x20cm size complete all as specified and directed . 30 Item No 29 : M&L forEarth electrode 25 mm dia 3 mtr long of low carbon steel electrode with copper bonding of thickness 250 micron,Back-fill earthing enhancing compoundtypeCarbon based compound conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill comound should be environment friendly & should be solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per as per IEC: 62561-7 for Back-fill compound shall be submitted along with the material including SS clamp to be provode both side and PVC EARTH PIT 300 X 300 MM WITH PLASTIC LID complete all as specified Note - (i) Earth electrode should be applicable Standards IS: 3043, IEC 62561-2 & IEC 60364-5 and made of High Tensile steel rods copper bounded, High tensile strength,good electrical conduction & effective performance and suitable for all type of soil and provided minimum distance 3 Mtrs. (ii) Back-fill compound should be Compliance to the Standards IEEE: 80, IS-3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification.(iii) Positive low resistance electrical connection to the earth. (iv) Does not contain hazardous chemicals.(v) Electronically conductive (like in metals) and is not dependent on moisture.(v) Provide the desire value of earth resistance as per required specified values.(vi) Cost of GI strip 32x6 mm length upto 5.0 mtrs & Bronze test point of size 75 x75x25 mm shall be includes in item rates. 31 Item No 30 : M & L for galvinised iron strip 32x6mm burried in ground/Fixed to tubular polefor earthing beyond 7.5m complete all as specified and directed.Note - Rates to be indcluded Mounting insulator for strip down conductor fixed to pole. 32 Item No 31 : M & L forRCC cable route indicator of size 800 x 350 x 50 MM dully marking by synthetic enamelled paint inBlue coulor forMES LT cable1.1 KV and Red colour of MES HT cable 11 KV and also markMES, grouting in PCC making good complete all as directed. Note - Earth work and PCC work to be measured in respective items here- in- before. 33 Item No 32 : Supply, installation, connection, testing and commissioningof 11KV Extensible Outdoor duty (IP 55 enclosure)4-way motor operated Ring Main Unit comprising of SF6 gas insulated 630 Amps Load Break Switchas incomer and 3 Nos Vacuum Circuit Breaker as each outgoing , cable termination from the front, breaking capacity 21KA/3 sec (Internal Arc Classification AFLR 21kA-1sec with Bottom Exhaust both for tank and cable box as per IEC 62271-200), enclosed in insulated welded stainless steel tank having IP67 Degree of Protection, leak rate of SF6 gas less than 0.1% and tested as per IEC 60056/60694/60298. Protection CTs shall be ring core type, complete all as specified and directed. The outer enclosure shall have IP 55 protection, it should be Top Opening Canopy type, Indoor RMU placed inside Outdoor Enclosure should not be acceptable. Both the Load break switch and Breaker should have line side earth switch. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer enclosure main door should cover entire part of the switchgear including front cover and cable doors for providing complete IP 54 protection complete all as specified and as directed.The RMU Unit comprising the following here in after Sel No - 33.01 to 33.05. 34 (A) Other details forRMU System Particulars : - (i) Nominal System Voltage : 11kV. (ii) Voltage variation on supply side : ±10 %. (iii) Corresponding Highest System Voltage: 12kV. (iv) Frequency : 50 Hz with ± 3 % tolerance. (v) Number of Phase : 3 Phases. (vi) Neutral earthling : Solidly earthed. (vii) Fault level (minimum) kA /Sec : 25/1). (viii) Lightning Impulse Withstand Voltage (kVp) : 75 (ix) One minute dry/wet power frequency withstand voltage primary (kV rms) : 28KV (x) Rated Dynamic Withstand Current (kAp) : 52.5KA. (xi) Number of Short Circuit Operations at rated short circuit current of 25 kA for Breaker - 50 Nos. (xii) Earth switch should have 5 closing operation at short circuit current (making operations E2 class) independent of breaker. Earth switch manual closing shall be driven by a fast acting / snap action mechanism, independent of operator and VCB action. (xiii) Side and rear cable entry is not acceptable, all operation, interlock, cable terminations and door shall be front side only. 35 (B) Applicable Standards for this RMU scope of work - IEC 62271-200. (i) The Ring Main Units shall conform to the latest applicable, IEC 62271-100, IEC 62271-200. (ii) All live parts, bus bars, shall preferably be enclosed in non- magnetic and non-ferrite grade stainless steel tank Grade SS441 of minimum 2 mm thickness. The RMU shall be type tested for internal arc test of 21KA/1 sec AFLR with Bottom Exhaust for Safety of Personnel for both Tank as well as Cable Compartment as per IEC62271- 200. The outer enclosure shall have IP 55 protection for complete switchgears, however it should be Top Opening Canopy & Indoor RMU placed inside Outdoor Enclosure should not be acceptable. The protection relay shall be for 3 O/C + 1E/F (IDMT Type) Self powered numerical protection relay with low and high set of over current and earth fault . (iii) Internal Arc Classification should be with Bottom exhaust only. RMUs should be manufactured, inspected, and invoiced from the OEM factory. 1 set of surge arrester fix in outgoing way, i.e. 3 o/g means 3 sets of surge arrester. (vi) VCB, Numerical Relay, HMI, FRTU an Thermal / climatic sensor should be of same make for better functioning, maintenance, and coordination. 36 (C) Air Insulated Bus Connected RMU Unit comprising: - Air Insulated enclosure withnecessary bus connection via bushing. VT’s from the manufacturer and according to IS 3156 shall beaccepted. (2) Provide 11KV/rt3/110V/rt3; 50VA class 0.5. Single phase bus PT for metering. (3) 11KV/230V AC,1KVA control transformer – Optional is Aux supply at site is not available. (4) MFM – EM 6400 NG Class 0.5 for each Incomer. (5) Metering CT in respective Function’s Cable Compartment in RMU XX/1A, Class 0.5, 2.5 VA. 37 (D) Accessories should be provide with RMU :-(1) Antireflex operating handle. (2) Battery 24V DC , 12Ah. (3) Battery charger (I/P230V AC, O/P - 24V DC). (4) double conical brass/compression steel glands suitable for upto cable of size 3C x 185 Cable for both incoming and Outgoing.(5) Detailed Technical datasheet/ GTP,operation manuals etc. 38 Note for RMU :-(i) RMU shall be mounting has to be least 60CM above the gorond i.e stand to be provided of at least 60 CM PCC foundation as per manufactures drawing. (ii) Cost of PCC /Earth work deemed to be included in the rate quoted. (iii) The contractor shall submit the NABL Accredited lab test reports of the RMUs in original and the same shall be produced well before claiming RAR payment of the RMU.(iv) Pre-despatch inspection shall be carried out by Rep of Accepting Officer. All arrangement for the same shall be arranged by the contractor & shall be considered within quoted rates.(v) Design, drawing of RMU to be submitted by the contractor for approval from the Garrison Engineer prior to manufacturing. 39 Item No 33 : Supply and installation of LBS (Load Break switch) with earth, 11KV, 630AMP 1 way motor operated Ring Main Unit Air insulated type 3 poles cpper Busbar in suitable size with internal wiring dust and outdoortype (IP 55) vermin proof. Busbars should be of copper, padlock provisions & complete with all accessories. The RMU shall be type tested for internal arc test of not less than 21KA/1 sec as per IEC62271-200. LBS shall be equipped with site replaceable bushing The LBS Unit comprising the following here in after Sel No - 39.01 to 39.05 . 40 (A) Other details forSystem Particulars : - (i) Nominal System Voltage : 11kV. (ii) Voltage variation on supply side : ±10 %. (iii) Corresponding Highest System Voltage: 12kV. (iv) Frequency : 50 Hz with ± 3 % tolerance. (v) Number of Phase : 3 Phases. (vi) Neutral earthling : Solidly earthed. (vii) Fault level (minimum) kA /Sec : 25/1). (viii) Lightning Impulse Withstand Voltage (kVp) : 75 (ix) ) Earth switch should have 5 closing operation at short circuit current (making operations E2 class) independent of breaker.. (xiii) Side cable entry for incoming and side/rear for Out going, all operation, interlock, cable terminations and door shall be front side only. 41 (B) Applicable Standards for this LBS scope of work - IEC 62265/IS9920. (i) The Ring Main Units shall confirm to the latest applicable, IEC 62271-100, IEC 62271-200. (ii) All live parts, bus bars, shall preferably be enclosed in non- magnetic of Minimum 2 mm thickness. The LBS shall be type tested for internal arc test of 21KA/1 sec AFLR with Bottom Exhaust for Safety of Personnel for both Tank as well as Cable Compartment as per IEC62271-200. The outer enclosure shall have IP 55 protection for complete switchgears, however it should be Top Opening Canopy & Indoor Load breaker switch placed inside Outdoor Enclosure should not be acceptable. The protection relay shall be for 3 O/C + 1E/F (IDMT Type) Self powered numerical protection (iii) Internal Arc Classification should be with Bottom exhaut. 42 (C) Air Insulated Bus Connected Unit comprising :-(1) Air Insulated enclosure with necessary bus connection via bushing. VT’s from the manufacturer and according to IS 3156 shall be accepted. (2) Provide 11KV/rt3/110V/rt3; 50VA class 0.5. Single phase bus PT for metering. (3) 11KV/230V AC,1KVA control transformer – Optional is Aux supply at site is not available. (4) MFM – EM 6400 NG Class 0.5 for each Incomer. (5) Metering CT in respective Function’s Cable Compartment in RMU XX/1A, Class 0.5, 2.5 VA. 43 (D) Accessories should be provide with RMU :-(1) Antireflex operating handle. (2) Battery 24V DC , 12Ah. (3) Battery charger (I/P230V AC, O/P - 24V DC). (4) double conical brass/compression steel glands suitable for upto cable of size 3C x 185 Cable for both incoming and Outgoing.(5) Detailed Technical datasheet/ GTP, operation manuals etc. 44 Note for LBS :-(i) LBS shall be mounting has to be least 60CM above the gorond i.e stand to be provided of at least 60 CM PCC foundation as per manufactures drawing. (ii) Cost of PCC /Earth work deemed to be included in the rate quoted. (iii) The contractor shall submit the NABL Accredited lab test reports of the RMUs in original and the same shall be produced well before claiming RAR payment of the RMU.(iv) Pre-despatch inspection shall be carried out by Rep of Accepting Officer. All arrangement for the same shall be arranged by the contractor & shall be considered within quoted rates.(v) Design, drawing of RMU to be submitted by the contractor for approval from the Garrison Engineer prior to manufacturing. 45 Item No 34 : Supply only the chain link fencing MS galvanised fencing ofsize 50x50 mm thickness not less than 3.00 mm complete all as specified for fixing to Item No - 23 here in after complete all as directed. 46 Item No 35 : Fixing only the Chain link fencing on MS picket post including line wires,any mesh, size and type to any type of standards, straining bolts,etc including provision of winding wire complete all as specified 47 Item No 36 : Supply and fixing angle iron made of mild steel confiriming to Fe 410-W (Gde-E 250) of size 50x50x6 mm as in post and sturds in fencing incl cutting top to shape as directed,and flat iron of size 50x6 mm drilling of holes as drected for chain link fencing to angle all as per directed.rate including dismanting to the old PCC fence post complete all as specified. Note - (i)Rates are includingrequired Nut bolts with washers any type any sizes for fixing ofchain lik fencing. (ii) PCC for post of picket shall be paid separatelly in respective items. 48 Item No 37 : Supply only the Mild steel round bar 10 mm dia and over conformingFe 410 - A for fixing to chain link fencing Note - Fixing charges including in the Item No 26 here - in- beforecomplete all directed. 49 Item No 38 : Supply and spreading stone aggregate of size not exceeding 40 mm spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for transformer andpole structure area all as directed
Contract Date: Mar 10, 2026 Contract Value : 3.42 Crore
Statutory Bodies & Commissions/Committees No of Bidders 10
18.
Educational and Research Institute #9392647 Technical Bid
Supply Of Printed Books As Per Tender Document , Supply Of Printed Books , Heat Transfer/Binay K. Dutta/Phi Learning Private Limited/978-81-203-1625-6 , Stoichiometry And Process Calculations/K.V.Narayanan And B.Lakshmikutty/Phi Learning Private Limited/978-8120352896 , Elements Of Chemical Reaction Engineering/H. Scott Fogler/Phi Learning Private Limited/978-7502741006 , Chemical Reaction Engineering/Octave Levenspiel/Wiley/978-8126510009 , Mass Transfer Operations/Robert Treybal/Mcgraw Hill Education/N/A , Transport Processes And Separation Process Principles/Chistie John Geankoplis/Pearson Education India/N/A , Principles Of Mass Transfer And Separation Processes/Binay K. Dutta/Phi Learning Private Limited/N/A , Chemical Process Safety: Fundamentals With Applications /Daniel Crowl , Joseph Louvar/Pearson Education India/N/A , Transport Phenomena/R. Byron Bird, Warren E. Stewart, Edwin N. Lightfoot/Wiley/N/A , Chemical Process Control: An Introduction To Theory And Practice/George Stephanopoulos/Pearson/N/A , Process Systems Analysis And Control/Steven E Leblanc Donald R. Coughanowr/Mcgraw Hill Education/N/A , Chemical Engineering Design: Principles, Practice And Economics Of Plant And Process Design/Gavin Towler, Ray Sinnott/Butterworth-Heinemann Ltd/N/A , Plant Design And Economics For Chemical Engineers/Max Peters, Klaus Timmerhaus, Ronald West, Max Peters/Mcgraw Hill/N/A , Unit Operations Of Chemical Engineering/Warren Mccabe/Mcgraw Hill Education/N/A , Process Plant Simulation/B.V Babu/Oxford University Press/N/A , A Textbook Of Machine Design/R.S.Khurmi/S Chand/N/A , Mechanical Operations Fundamental Principles And Applications/Dr. Kiran D. Patil/Nirali Prakashan/N/A , Unit Operation -1/K. A. Gavhane/Nirali Prakashan/N/A , A Textbook Of Heat And Mass Transfer/Rk Rajput/S Chand/N/A , Numerical Methods For Engineers/Steven Chapra Raymond Canale/Mcgraw Hill Education/N/A , A Text Book Of Railway Engineering/Saxena S.C /Dhanpat Rai Publication/N/A , Adsorption Analysis: Equilibria And Kinetics (With Cd Containing Computer Matlab Programs): 2 (Series On Chemical Engineering)/ Duong D Do/Imperial College Press/978-1860941375 , Advanced Concrete Technology/Zongjin Li/John Wiley & Sons Ltd/978-0470437438 , Advanced Mechanics Of Solids/Srinath, L.S./Tata Mcgraw-Hill/978-0070139886 , Advanced Reinforced Concrete Design/Krishnaraju N/Cbs Publishers/978-8123929606 , Alkali-Aggregate Reaction And Structural Damage To Concrete /Geoffrey E Blight/Crc Press/978-1138073036 , An Introduction To The Finite Element Method/Reddy, J.N./Mcgraw Hill/978-9390385270 , Basic Structural Analysis/Reddy, C. S./Tata Mcgraw Hill/978-0070702769 , Classical And Computational Solid Mechanics/Fung,Tong And Chen/World Scientific Publishing Co Pte Ltd/978-0000988508 , Concrete Structures/Bhattacharjee J/Cbs Publishers/978-9385915901 , Concrete Structures Subjected To Impact And Blast Loadings And Their Combinations/Zhang Chunwei/Taylor & Francis Ltd/978-1032200514 , Concrete Technology/A M Neville/Pearson Education/978-8131705360 , Construction Materials Their Nature And Behaviour/Marios Soutsos, Peter Domone/Crc Press/978-1498741101864 , Design Of Reinforced Concrete Structures/Subramanian N/Oup India/978-0198086949 , Dynamics Of Structures/Clough,R.W. And Penzien, J/Mcgraw Hil/978-8123926636 , Elasticity And Plasticity: The Mathematical Theory Of Elasticity And The Mathematical Theory Of Plasticity/J.N. Goodier/Dover Publications Inc./ 978-0486806044 , Elements Of Strength Of Materials/Timosenko, S. P., And Young, D.H./Affiliated Eastwestpress Pvt. Ltd/978-8176710190 , Engineering Mechanics Of Solids/Popov, E.P./Pearson Education India/9332550216 , Environmental Engineering/Howard S Peavy, Donald R Rowe/Mcgraw Hill Education/978-9351340263 , Environmental Engineering (Vol. I) Water Supply Engineering/Santosh Kumar Garg/Khanna Publishers/978-8174091208 , Environmental Engineering (Vol. Ii) Sewage Waste Disposal And Air Pollution Engineering/Santosh Kumar Garg/Khanna Publishers/978-8174092304 , Finite Element Analysis: Theory And Programming/C. S. Krishnamurthy/Mcgraw Hill/978-0074622100 , Foundations Of The Theory Of Elasticity, Plasticity, And Viscoelasticity /Eduard Starovoitov And Faig Bakhman Ogli Naghiyev/Apple Academic Press Inc./978-1774631997 , Handbook Of Solid Waste Management/George Tchobanoglous, Frank Kreith /Mcgraw Hill Education/978-0071356237 , Highway Engineering/Khanna & Justo/Nemchand Publisher/8185240930 , Industrial Water Pollution Control/W Wesley Eckenfelder/Mcgraw Hill Education/978-9339220433 , Integrated Design And Environmental Issues In Concrete Technology/K Sakai/Crc Press/978-0367864620 , Intermediate Structural Analysis/Wang, C.K./Mcgraw Hill Education/978-0070702493 , Introduction To Solid Mechanics/Shames, H/Phi/978-9332549906 , Introduction To Traffic Engineering/R Srinivasa Kumar/The Orient Blackswan; South Asian Edition/9386235471 , Matrix And Finite Element Analysis Of Structures/Madhujit Mukhopadhay And Abdul Hamid Sheikh/Anebooks Pvt. Ltd./978-81-8052-075-4 , Microwave-Assisted Concrete Technology/Ong K.C. Gary/Crc Press/978-1138748897 , Prestressed Concrete /Krishnaraju N/Mcgraw Hill Education India/978-9387886209 , Principles Of Adsorption And Adsorption Processes/ Douglas M. Ruthven/Wiley-Interscience/978-0471866060 , Properties Of Concrete/A M Neville/Pearson Education/978-0273755807 , Random Vibrations Of Elastic Systems/Bolotin, V. V./Springer/978-9048182800 , Recent Trends In Solid Waste Management (Advances In Pollution Research)/Balasubramani Ravindran,Sanjay Kumar Gupta/Elsevier - Health Sciences Division/978-0443152061 , Reinforced Concrete: Mechanics And Design, Global Edition /Wight James/Pearson Education Limited/978-1292106007 , Soil Mechanics And Foundation Engineering - Geotechnical Engineering/K.R.Arora/Standard Publisher Dist/8180141128 , Solid Mechanics /Kazimi, S. M.A/Tata Mcgraw-Hill/978-0074517154: ? , Sprayed Concrete Technology/Simon Austin/Crc Press/978-0367865412 , Standard Methods For The Examination Of Water And Wastewater/William C. Lipps, Ellen Burton Braun-Howland, Terry E. Baxter/American Public Health Association/978-0875532998 , Statically Indeterminate Structures/Wang, C.K./Mcgraw Hill Book Company/978-9352604722 , Strength Of Materials/Srinath, L.S, Desayi./Macmillan Publishers India/978-0333923924 , Strength Of Materials, Part 1/Timoshenko, S/Mcgraw Hill/978-8123910307 , Strength Of Materials, Part 2/Timoshenko, S/Mcgraw Hill/978-8123910772 , Structural Dynamics/Mario Paz/Cbs Publications/978-8181287724 , Structural Dynamics- Theory And Application To Earthquake Engg/Anil K Chopra/Pearson Education/978-9353945251 , Structural Dynamics: Vibrations And Systems/Mukhopadhyaya, M./Ane Books /978-8180520907 , Sulfate Attack On Concrete/Jan Sklany/Taylor & Francis Ltd/978-0367447144 , Textbook Of Highway And Traffic Engineering/Saxena S.C /Cbs /978-8123924175 , The Finite Element Method Its Basis & Fundamentals/Zienkiewicz, Taylor And Zhu/Elsevier/978—81-312-118-2 , Theory Of Elasticstability/Timoshenko, S.P. And Gere, J. M./Tata Mcgraw Hill./978-0-07-0702417 , Theory Of Elasticity/Timoshenko And Goodier/Mcgraw Hill/978-0070701229 , Theory Of Elasticity And Plasticity: A Textbook Of Solid Body Mechanics/Antonina Molotnikova And Valentin Molotnikov /Springer Nature/978-3030666248 , Theory Of Plates And Shells/Timoshenko And Kriger/Tata Mcgraw Hill/978-0-07-070125-0 , Traffic & Highway Engineering/Nicholas J. Garber/Cengage India Private Limited/978-8131529430 , Traffic Engineering/R P. Roess (Author), Elena S. Prassas (Author), William R. Mcshane (Author)/Pearson Education/9353434858 , Wastewater To Water: Principles, Technologies And Engineering Design/Makarand M. Ghangrekar/Springer Verlag, Singapore/978-9811940507 , Soil Dynamics And Machine Foundations/Swami Saran/Galgotia Publication S Pvt. Ltd./978-8175157279 , Soil Mechanics And Foundation Engineering/K. R. Arora/Standard Publishers/978-8180141126 , Basic And Applied Soil Mechanics/Gopal Ranjan, Asr Rao/New Age International/9788122440393, , Design Of Steel Structures/N. Subramanian/Oxford University Press/978-0199460915 , Fundamental Concepts Of Earthquake Engineering /Roberto Villaverde/Crc Press/1420064959 , Civil Engineering Drawing /M Chakraborti// , Data Mining Concepts And Techniques /Jiawei Han, Jian Pei,Hanghang Tong/Elsevier/9788131267660 , Data Science In Practice/Tom Alby/Chapman & Hall/9781032505268 , Introduction To Data Science: Practical Approach With R And Python/B. Uma Maheswari, R. Sujatha/Wiley/9789354640506 , Transformers For Natural Language Processing And Computer Vision - Third Edition/Denis Rothman/Packt Publishing/9781805128724 , Generative Deep Learning/ David Foster/Oreilly Media/9781098134181 , Introduction To Machine Learning /Ethem Alpayd?N/Mit Press/9780262043793 , Data Mining With R/Luis Torgo/Taylor And Francis/9780367372453 , Bioinformatics And Functional Genomics/Jonathan Pevsner/Wiley Blackwell Pub/978-1118581780 , Bioinformatics Basics: Applications In Biological Science And Medicine/ Lukas K. Buehler/Crc Press/978-0367392598 , What Is The Name Of This Book?/Raymond M. Smullyan/Dover Publications Inc./978-0486481982 , The Lady Or The Tiger?/Raymond M. Smullyan/Dover Publications Inc./978-0486470276 , The Riddle Of Scheherazade: And Other Amazing Puzzles, Ancient And Modern./Raymond M. Smullyan/Knopf/978-0679446347 , Convex Optimization/Stephen Boyd, Lieven Vandenberghe/Cambridge University Press/978-0521833783 , Genetic Algorithms In Search, Optimization And Machine Learning/David E. Goldberg/Pearson/978-8131709931 , Steganography In Digital Media: Principles, Algorithms, And Applications/Jessica Fridrich/Cambridge/978-0521190190 , Deep Learning From Scratch: Building With Python From First Principles/Seth Weidman/Shroff/Oreilly/978-9352139026 , Wireless Communication Systems /Rajeshwar Dass./Wiley/978-9389583687 , Semiconductor Materials, Devices, And Fabrication, As Per Aicte/Parasuraman Swaminathan/Wiley/978-8126508624 , Introduction To 4G Mobile Communications/Juha Korhonen/Artech House Publishers/978-1608076994 , An Introduction To Lte/Cox Christopher/Wiley/978-1118818039 , Fourth Generation Mobile Communication/Curwen Peter/Springer International Publishing Ag/978-3319022093 , Advanced Wireless Communications: 4G Technologies/Savo G. Glisic/Wiley–Blackwell/978-0470867761 , 4G Wireless Communication Networks: Design Planning And Applications/Johnson I. Agbinya, Mari Carmen Aguayo-Torres, Ryszard Klempous/River Publishers/978-8792982711 , Fundamentals Of Lte/Rews, Rias Muhamed, Arunabha Ghosh, Jun Zhang, Jeffrey G./Pearson/978-9353062392 , 5G Mobile Communications/Wei Xiang, Kan Zheng, Xuemin (Sherman) Shen/Springer International Publishing Ag/978-3319342061 , 5G Mobile Core Network: Design, Deployment, Automation, And Testing Strategies/Rajaneesh Sudhakar Shetty/Springer India/978-1484283288 , 5G Mobile And Wireless Communications Technology/Afif Osseiran, Jose F. Monserrat, Patrick Marsch, Mischa Dohler, Takehiro Nakamura/Cambridge University Press/978-1107130098 , Towards 5G: Applications, Requirements And Candidate Technologies/Rath Vannithamby, Shilpa Talwar/Wiley/978-1118979839 , Fundamentals Of 5G Mobile Networks/Jonathan Rodriguez/Wiley/978-1118867525 , A Course In Electrical And Electronic Measurements And Instrumentation/A.K. Sawhney/Dhanpat Rai & Co. (P) Limited;/978-8177001006 , A Course In Electrical Machine Design/A.K. Sawhney/Dhanpat Rai & Co. (P) Limited /978-8177001013 , A Course In Electrical Technology (Basic Electrical Engineering Volume I)/J.B.Gupta/S.K. Kataria & Sons/81-85749-29-9 , A First Course On Electrical Drives/S.K.Pillai/New Age International Publishers/978-8122433616 , A Text Book Of Electrical Technology (Vol.1)/B.L.Theraja, A.K.Theraja/S.Chand Technical/9788121924405 , A Textbook Of Electrical Technology Volume Ii : Ac And Dc Machines/B.L.Theraja, A.K.Theraja/S Chand/978-8121924375 , Advanced Electrical Technology/H. Cotton/Reem Publications Pvt. Ltd. /978-8190630719 , An Integrated Course In Electrical Engineering/J.B.Gupta/S.K. Kataria & Sons/9-789350143681 , An Introduction To Analog And Digital Communication Systems/ Simon Haykin, Michael Moher /Wiley/978-8126536535 , An Introduction To The Principles Of Digital Communications/N.B.Chakraborti, A.K.Datta/New Age International Publishers/978-8122420838 , Analog Communication Systems/Sanjoy Sharma/S.K. Kataria & Sons/978-9350143797 , Artificial Intelligence And Intelligent Systems/N.P. Padhy/Oxford University Press/978-0195671544 , Artificial Neural Networks/B. Yegnanarayan/Prentice-Hall Of India Pvt. Ltd., New Delhi/ 978-8120312531 , Automatic Control System/ B. C. Kuo/ Prentice Hall Of India/9788120309685 , Automatic Control Systems (With Matlab Programs)/S. Hasan Saeed/Arihant Publisher/978-8190691925 , Basic Electrical Engg./D.P. Kothari & I.J. Nagrath/Mcgraw-Hill/9780070146112 , Basic Electrical Engg./V.K.Mehta, Rohit Mehta/S.Chand /978-8121908719 , Basic Electrical Engineering/A.E Fitzgerald, David E. Higginbotham, Arvin Grabel/ Mcgraw Hill Education/978-0070682566 , Circuit Theory (Analysis & Synthesis)/A.Chakraborti/Dhanpat Rai & Co./9788177000009 , Circuit Theory & Network/S. P. Ghosh And A. K. Chakraborty/Tata Mcgraw-Hill Education/9780071329040 , Communication Systems/Sekar, V. Chandra//978-0198078050 , Control System Engineering (Student Edition)/Norman Nise/John Wiley & Sons/978-8126537280 , Control Systems - I /S. Hasan Saeed/S.K. Kataria & Sons/978-9350141335 , Control Systems Engineering/I.J. Nagrath &M.Gopal/New Age International Pvt Ltd Publishers/9789386070111 , Design And Applications Of Analog Integrated Circuits/Soclof/Phi Learning Private Limited/978-81-203-2552-4 , Digital Communications/Sanjoy Sharma/S.K. Kataria & Sons/978-9350142684 , Digital Control Engineering/M. Gopal/New Age International Publishers/978-8122436617 , Digital Control Systems/B.C.Kuo/Oxford University Press/978-0198083542 , Digital Design/M. Morris Mano/Prentice Hall/978-0132774208 , Digital Electronics /G.K.Kharate/Oxford University Press/9-780198061830 , Digital Integrated Electronics/H. Taub And D. L. Schilling/Mcgraw Hill Education/978-0070265080 , Digital Signal Processing/Monson H Hayes/Tata Mcgraw - Hill Education/978-0070153868 , Digital Signal Processing/P.Ramesh Babu/Scitech Publications/978-8183710817 , Digital Signal Processing/B. Kumar/New Age International Publishers/978-8122436099 , Digital Signal Processing: A Computer Based Approach/S. K. Mitra/Mcgraw Hill Education/978-1259098581 , Direct Energy Conversion/Kettani, M. Ali/Addison-Wesley/ 97-80201036633 , Direct Energy Conversion/Stanley W. Angrist/Allyn And Bacon/978-0205077588 , Distributed Generation: Induction And Permanent Magnet Generators/Loi Lei Lai, Tze Fun Chan/Wiley/978-0470062081 , Distributed Generation: The Power Paradigm For The New Millennium/Anne-Marie Borbely, Jan F. Kreide/Crc Press/978-1420042399 , Electric And Hybrid Vehicles/Tom Denton/Routledge/9781138842373 , Electric Circuits /David. A. Bell/Oxford University Press/9780195694284 , Electric Energy Systems Theory-An Introduction/Olle I. Elgerd/Tata Mcgraw Hill/9780070992863 , Electric Machines/ I. J. Nagrath And D. P. Kothari/Tata Mcgraw Hill/978-0070699670 , Electrical Circuit Analysis (Including Passive Network Synthesis)/C.L.Wadhwa/New Age International Publishers/978-8122418521 , Electrical Engineering Fundamentals/Vincent Del Toro/Phi Learning Private Limited/978-8120305991 , Electrical Engineering Materials/T.K.Basak/New Age International Publishers/978-8122427738 , Electrical Machinery/Dr. P.S.Bimbhra/Khanna Publishers/978-8174091734 , Electrical Machinery /S. K. Sen/Khanna Publishers /978-8174091529 , Electrical Machines/R.K.Rajput/Laxmi Publications(P) Ltd./978-8131804469 , Electrical Machines /S.K.Bhattacharya/Tata Mcgraw-Hill Education/978-9332902855 , Electrical Measurements And Measuring Instruments/ E.W Golding, F.C Widdis/Reem Publications Pvt. Ltd/978-8190630726 , Electrical Power System Quality/R.C.Dugan/Tata Mcgraw-Hill Education, 2003/978-1259005572 , Electrical Power Systems/Ashfaq Husain/Cbs Publishers & Distributors/978-8123914480 , Electromagnetic Fields & Waves96/Sarwate V.V./New Age/81-224-0468-5 , Electromagnetic With Application/J. D. Krauss/Tata Mcgraw Hill/9780070702400 , Electromagnetics/B.B.Laud/New Age International Publishers/978-8122430554 , Electromagnetism – Theory And Applications/Ashutosh Pramanik/Prentice-Hall Of India/978-8120319578 , Electronic Devices And Circuit Theory/R. Boylestad And L. Nashelsky/Prentice Hall Publishing Co/978-0132504577 , Electronic Devices And Circuits/J. Millman And C. C. Halkias/Mcgraw Hill Education/978-0070423800 , Electronic Instrumentation/H.S.Kalsi/Mcgraw Hill Education/978-0070702066 , Elements Of Advanced Quantum Theory/J.M. Ziman/Camridge University Press/521-07458-4 , Elements Of Electrical Power Station Design/M.V.Deshpande/Prentice Hall India Learning Private Limited /978-8120336476 , Elements Of Photonics Vol-1 /Keigo Lizuka/Wiley-Interscince/0-471-83938-8 , Elements Of Power System Analysis/W.D. Stevenson/Mcgraw Hill Higher Education/978-0070665842 , Energy Economics: Concepts, Issues, Markets And Governance/Subhes C. Bhattacharyya/ Springer/978-1447174707 , Energy Science Principles, Technologies And Impact/J. Andrews, N. Jelley/Oxford University Press/978-0198755814 , Energy Technology - Nonconventional, Renewable & Conventional/S.Rao, Dr. B.B.Parulekar/Khanna Publishers/97-88174090401 , Energy Technology (Non Conventional, Renewable And Conventional)/Prof. Sunil S. Rao And Dr. B.B. Parulekar/Khanna Publishers/978-81-7409-040-9 , Engineering Circuit Analysis/W. H. Hayt , J. Kemmerly /Mcgraw Hill Education/978-1259098635 , Engineering Electromagnetic/W. H. Hayt & J. A. Buck/Mcgraw-Hill/978-9353169725 , Engineering Electromagnetics/Hayat/Tmh/0-07-061223-4 , Engineering Optimization Theory And Practice/Singiresu S. Rao/New Age International Publishers/978-8122427233 , Engineering Thermodynamics/P.K.Nag/ Mcgraw Hill Education/978-9352606429 , Explanations / Solutions To An Integrated Course In Electrical Engineering (With About 15,000 Objective Type Questions & Answers) /J.B.Gupta/S.K. Kataria & Sons/978-9350146668 , Facts Controllers In Power Transmission And Distribution/K.R. Padiyar/New Age International Publishers/978-8122421422 , Fiber Optics Essentials/K. Thyagarajan & Ajoy Ghatak/Wiley-Interscince/978-0-470-09742-7 , Fiber Optics Through Experiments Paperback – 2011/Ajoy Ghatak, M. R. Shenoy /Viva Books (2011)/978-8130918112 , Fiber-Optic Communication Systems/Govind P. Agrawal/Wiley/978-8126513864 , Fibre Optics And Optoelectronics/R.P.Khare/Oxford University Press/9-780195669305 , Flexible Ac Transmission Systems/Yong Hua Song, Allan T. Johns/ Laxmi Publications /978-8190858809 , Fundamentals Of Digital Circuits/A. Anand Kumar/Prentice-Hall Of India Pvt. Limited/978-8120352681 , Fundamentals Of Electric Circuits/Charles K. Alexander, Matthew N. O. Sadiku/Mcgraw Hill Education (India) Private Limited/978-9355320162 , Fundamentals Of Microprocessors And Microcontrollers/B. Ram/Dhanpat Rai Publications (P) Ltd/978-9383182107 , Fundamentals Of Optical Wave Guides/Katsunari Okamoto/Elsevier/978-0-12-525-096-2 , Fundamentals Of Photonics /Bahaa E. A. Saleh, Malvin Carl Teich/ John Wiley & Sons, Inc./0-471-2-1374-8 , Fundamentals Of Power Electronics/Robert W. Erickson, Dragan Maksimovic/Springer Us/978-1-4757-0559-1 , Generation Distribution And Utilization Of Electrical Energy/C.L. Wadhwa/New Age International Publishers/978-8122428216 , Getting Started With Matlab/Rudra Pratap/Oxford University Press/978-0198069195 , Goldings Electrical Measurements And Measuring Instruments/Golding & Widdis/Medtech Publishers/978-9387210349 , Handbook Of Energy Conservation, Vol. 1/H.M. Robert, J.H. Collins/Cbs Publishers & Distributors/9-788123912066 , Handbook Of Energy Conservation, Vol. 2/H.M. Robert, J.H. Collins/Cbs Publishers & Distributors/9-788123912073 , High Voltage Engineering/C.L.Wadhwa/New Age International Publishers/978-8122430905 , High Voltage Engineering/M.S Naidu & V Kamaraju/Mcgraw Hill Education/978-1259062896 , High Voltage Engineering: Problems & Solutions/R.D. Begamudre/New Age International Publishers/978-8122426182 , Hvdc Power Transmission Systems/K.R. Padiyar/New Age International Publishers/978-8122437850 , Industrial Energy Conservation Techniques : Concepts, Applications And Case Studies /K. Nagabhushan Raju/Atlantic Publishers And Distributors (P) Ltd/978-8126907748 , Industrial Instrumentation/Donald P. Eckman/Cbs Publisher/978-8123908106 , Industrial Instrumentation/K.Krishnaswamy, S. Vijayachitra/New Age International Publishers/978-8122427509 , Industrial Instrumentation, Control And Automation/Mukhopadhay, Sen & Deb/Jaico Publishing House/978-8184954098 , Instrumentation And Control/Patranabis/Phi Learning Private Limited/978-81-203-4246-0 , Introduction To Digital Signal Processing/J.R. Johnson/ Prentice Hall India Learning Private Limited /978-8120307605 , Introduction To Fiber Optics (English) 1St Edition/Ajoy Ghatak , K. Thyagarajan/Cambridge University Press-New Delhi/97-88175960626 , Introduction To Quantum Mechanics/David J. Griffiths/Prentice Hall/0-13-124405-1 , Introduction To Quantum Mechanics/A.C. Philips/John Wiley & Sons, Inc./0-470-85323-9 , Introduction To Solid State Physics/ Charles Kittel /Wiley & Sons/978-8126535187 , Lasers And Non-Linear Optics/B.B.Laud/New Age International Publishers/978-8122430561 , Linear Integrated Circuits/D. Roy Choudhury, Shail B. Jain/New Age International Publishers/978-8122430981 , Matrix Analysis Of Electrical Machines/Ashoke Kumar Mukhopadyhay/New Age International Publishers/978-8122432398 , Microcomputer Systems: The 8086/8088 Family/I. Liu, G. A. Gibson/ Prentice Hall India Learning Private Limited/978-8120304093 , Microelectronic Circuits: Theory And Applications/A.S. Sedra And K.C. Smith/Oxford University Press/978-0199476299 , Microelectronics/J. Millman And A. Grabel/Mcgraw Hill Education/978-0074637364 , Microprocessor Architecture, Programming And Applications With The 8085A/8080A/Ramesh S. Gaonkar/Wiley Eastern Ltd./978-0852262979 , Microprocessors Interfacing/Douglas Hall/Mcgraw Hill Education/978-1259006159 , Modern Digital And Analog Communication Systems/B.P.Lathi/Oxford University Press/978-0198073802 , Modern Electronic Instrumentation And Measurement Techniques /A D Helfrick; W D Cooper/ Prentice Hall India Learning Private Limited/?978-9332556065 , Modern Power System Analysis/I.J. Nagrath And D.P. Kothari/Mcgraw Hill Education/978-0071077750 , Modern Quantum Mechanics /J.J.Sakurai/Addison -Wesley Publishing Company/0-201-53929-2 , Network Analysis And Synthesis/S. P. Ghosh And A. K. Chakraborty/Tata Mcgraw-Hill Education/9781259081422 , Network Analysis And Synthesis/Franklin F. Kuo /Wiley/978-8126510016 , Network Analysis And Synthesis (Including Linear System Analysis)/C.L.Wadhwa/New Age International Publishers/978-8122420364 , Networks And Systems/D. Roy Choudhury/New Age International Publishers/978-8122427677 , Neural Networks In Computer Intelligence /F. Limin/Mcgraw Hill Education/978-0070532823 , Neural Networks, Fuzzy Logic And Genetic Algorithms: Synthesis And Applications/S. Rajasekaran And G.A. Vijaylakshmi Pai,/Prentice-Hall Of India Pvt. Ltd., New Delhi/978-8120321861 , Non Conventional Energy Resources/D.S. Chauhan, S.K.Srivastava/New Age Int.(P) Ltd/978-81-224-3399-9 , Non-Conventional Energy Resources/B.H. Khan/Tata Mcgraw Hill/978-0070142763 , Non-Conventional Energy Resources/D.S. Chauhan/New Age International Publishers/978-8122433999 , Non-Conventional Energy Sources/G.D. Rai/Khanna Publishers/9-788174090737 , Nonlinear Fiber Optics/Govind P. Agrawal/Optics And Photonics/N/A , Nonlinear Optics /Robert W. Boyd/Academic Press/0-12-121682-9 , Objective Electrical Technology/V.K.Mehta, Rohit Mehta/S. Chand Publishing/978-9355014467 , Op-Amps And Linear Integrated Circuits/Gayakwad/Phi Learning Private Limited/978-81-203-2058-1 , Operational Amplifiers And Linear Ics/David. A. Bell/Oxford University Press/978-0195696134 , Optical Electronics /A.K.Ghatak & K.Thyagarajan/Camridge University Press/0-521-30643-4 , Optical Waves In Crystals/Amnon Yariv & Pochi Yeh/Wiley-Interscince/0-471-09142-1 , Optimization Of Power System Operation/Jizhong Zhu/Wiley/978-1-118-85415-0 , Parker Smiths 500 Solutions Of Problems In Electrical Engineering (Part 1)/V.C Nateshan/Cbs /N/A , Performance And Design Of Ac Machines/M. G. Say/Cbs Publishers/978-8123910277 , Photonics/Amnon Yariv & Pochi Yeh/Oxford University Press/978-0-19-517946-0 , Power Electronics/Dr. P. S. Bhimbra/Khanna Publisher/978-81-7409-279-3 , Power Electronics: Converters, Applications, And Design/Ned Mohan, Tore M. Undeland, William P. Robbins/Wiley India/978-8126510900 , Power Electronics: Devices, Circuits And Applications/Muhammad H Rashid/Pearson Education/978-9332584587 , Power Electronics: Essentials & Applications/L. Umanand/Wiley/978-8126519453 , Power Generation, Operation, And Control/Allen J. Wood, Bruce F. Wollenberg/John Wiley & Sons/978-8126508389 , Power Plant Engineering/Arora & Domkundwar/Dhanpat Rai & Co. (P) Limited/978-8177001952 , Power Plant Engineering/A.K.Raja, Amit Prakash Srivastava, Manish Dwivedi/New Age International Publishers/978-8122418316 , Power Plant Technology/M.M.El-Wakil/Mcgraw Hill Education/978-0070702448 , Power System Analysis/J.J.Grainger, W.D.Stevenson/Tata Mcgraw-Hill/978-0070612938 , Power System Analysis: Operation And Control/ Abhijit Chakrabarti, Sunita Halder/Phi Learning Pvt. Ltd./ 978-8120340152 , Power System Optimization: Stability And Control/K. R. Padiyar/Anshan Ltd./978-1904798019 , Power System Optimization/D .P. Kothari And J.S Dhillon/Prentice Hall India Learning Private Limited/?978-8120340855 , Power System Prorection And Switchgear/B. Ravindranath And M. Chander/New Age International Publishers/978-8122430325 , Power System Protection/S. P. Patra, S. K. Basu, S. Choudhuri/Oxford & Ibh Publishing Co./N/A , Power System Protection And Communications/Akhter Kalam/New Age International Publishers/978-8122427417 , Power System Protection And Swichgear/B. Ravindranath, M. Chander/New Age International Publishers/978-8122430325 , Power System Restructuring And Deregulation/Loi Lei Lai/John Wiley & Sons Ltd /978-8126547234 , Power System Stability Vol-I/E.W.Kimbark/John Wiley & Sons/978-8126512577 , Power System Stability And Control/Prabha Kundur/Tata Mcgraw-Hill Education Private Limited/978-0070635159 , Power System Stability Vol-Ii/E.W.Kimbark/John Wiley & Sons/978-8126512577 , Power Systems Analysis/ Arthur Bergen, Vijay Vittal / Pearson/978-0136919902 , Principles Of Electromagnetics/Matthew N.O. Sadiku/Oxford University Press/9780198062295 , Principles Of Electronic Instrumentation/Patranabis/Phi Learning Private Limited/978-81-203-3355-0 , Principles Of Industrial Instrumentation/D. Patranabis/Mcgraw Hill Education/978-0070699717 , Principles Of Power Systems/V.K.Mehta, Rohit Mehta/S.Chand & Co./978-8121924962 , Principles Of Process Control/ D. Patranabis/Tata Mcgraw Hill/978-0071333252 , Principles Of Signal Processing And Linear Systems/B.P.Lathi/Oxford University Press/978-0198062288 , Problems And Solutions In Power Systems/Abhijit Chakrabarti /Abhijit Chakrabarti /978-9334032581 , Problems In Electrical Engineering(Power Engineering And Electronics With Answers Partly Solved In S.I. Units)/N. N. Parker Smith/Cbs Publisher/978-8123908588 , Process Control (Concepts, Dynamics & Applications)/S.K.Singh/Phi Learning Private Ltd./978-8120336780 , Process Control (Principles & Applications)/Surekha Bhanot/Oxford University Press/978-0195693348 , Process Dynamics And Control/D.E. Seborg, T.F. Edgar And D.A. Mellichamp/Wiley/978-8126541263 , Process Systems Analysis And Control/D.R. Coughanowr And L.B. Koppel/Mcgraw-Hill/978-0070851122 , Pulse Width Modulation For Power Converters: Principles And Practice/D. Grahame Holmes, Thomas A. Lipo/Wiley Ieee Press/978-0-471-20814-3 , Quantum Optics/Harry Paul/Camridge University Press/978-0-511-19475-7 , Reliability And Life Estimation Of Power Equipment/T.S.Ramu And Chakradhar Reddy/New Age International Publishers/978-8122426113 , Renewable Energy For Sustainable Future/Godfrey Boyle/Oxford University Press/978-0199681273 , Research Insights: A Handbook On Grant Writing And Program Management/ Rajiv K. Tayal/Atlantic Publishers And Distributors Pvt Ltd./978-8126935451 , Semiconductor-Laser Fundamentals/Weng W. Chow & Stephen W. Koch/Springer/3-540-64166-1 , Sensors And Transducers/Patranabis/Phi Learning Private Limited/978-81-203-3355-0 , Signals And Systems/H. P. Hsu/Mcgraw Hill Education (India) Private Limited/978-0070669185 , Signals And Systems/A.V. Oppenheim, Schafer, R. W, A.S. Willsky And I.T. Young/ Pearson Education India/9332550239 , Smart Grid Technology And Application/Janaka Ekanayake, Kithsiri Liyanage, Jianzhong Wu, Akihiko Yokoyama And Nick Jenkins/Wiley Publications/978-0-470-97409-4 , Smart Grid: Concepts To Design/K. S. Manoj/Notion Press/9781646780006 , Smart Grid: Fundamental Of Design And Analysis/James Momoh/Wiley Publication/978-8126558124 , Solar Cell Device Physics/Stephen Fonash/Academic Press/978-0080912271 , Solar Cells: Operating Principles, Technology, And Systemapplications/Martin A. Green/Prentice-Hall/978-0138222703 , Solar Electricity Generation/S. Bhattacharjee/ Narosa Publishing House/97-88184874044 , Solar Energy/S.P. Sukhatme, J K Nayak/Tata Mcgraw Hill/978-9352607112 , Solar Photovoltaics: Fundamentals, Technologies And Applications/Chetan Singh Solanki/Phi Learning/978-8120351110 , Solid State Physics/A.J. Dekker/ Macmillan/978-0333106235 , Solid State Physics/ S.O. Pillai /New Age International Private Limited/978-9389802313 , Sustainable Energy Management/Mirjana Radovanovi? (Golusin),Stevan Popov,Sinisa Dodic /Elsevier/978-0124159785 , Taubs Principles Of Communication Systems /H. Taub And D.L. Shilling/Mcgraw Hill Education/978-0070648111 , The 8051 Microcontroller And Embedded Systems/Muhammed Ali Mazidi And Janice Gillispie Mazidi/Pearson Education India/978-0138610227 , The Theory Of Optics/Paul Drude/Longmans, Green & Co./N/A , Theory & Performance Of Electrical Machines/J.B.Gupta/S.K. Kataria & Sons/978-9350142776 , Thermal Engineering/R.K.Rajput/ Laxmi Publications/978-8131808047 , Understanding Facts: Concepts And Technology Of Flexible Ac Transmission Systems/Narain G. Hingorani, Laszlo Gyugyi/Wiley India Pvt Ltd./978-8126530403 , Signals And Systems /Ramesh Babu/Scitech Publications/978-81-8371-288-0 , Fundamentals Of Industrial Instrumentation /Barua/Wiley India/9788126528820 , Bioinstrumentation /Fulekar/Wiley India/9789389520286 , Wileys Gate Instrumentation Engineering Chapter-Wise Solved Papers (2000-2020)/Gupta/Wiley India/9788126558698 , Electronic Measurement & Instrumentation /Imam/Wiley India/9789389583021 , Electrical Measurements And Measuring Instruments/Kamakshaiah/Wiley India/9789389447521 , A Treatise On Instrumentation Engineering /Padmanabhan/Wiley India/9789389633832 , Instrumentation And Process Control /Prasad/Wiley India/9789389307191 , Biomedical Electronics And Instrumentation Made Easy /Sawhney/Wiley India/9789389795943 , Medical Instrumentation 5Ed: Application And Design, An Indian Adaptation /Webster/Wiley India/9789354249150 , Lasers And Optical Instrumentation /Nagabhushana/Wiley India/9789389698756 , Automatic Control Engineering /Gupta/Wiley India/9789389583748 , Power System Analysis: Operation And Control, 2Ed/Jena/Wiley India/9789389520415 , Process Control Engineering /Krishna/Wiley India/9789389633429 , Quality Control/Kulkarni/Wiley India/9788126519071 , Control Engineering/Kuttan/Wiley India/9789389520064 , Digital Control, W/Cd /Moudgalya/Wiley India/9788126522064 , Nises Control Systems Engineering, Wiley India Ed/Nise/Wiley India/9788126571833 , Control Systems /Padmanabhan/Wiley India/9789389633375 , Control Engineering/Ramachandran/Wiley India/9788126522880 , Power System: Operation & Control/Rao/Wiley India/9788126534418 , Matlab With Control System, Signal Processing And Image Processing Toolboxes, W/Cd /Sivanandam/Wiley India/9788126554751 , Statistical Quality Control: A Modern Introduction, 6Ed /Montgomery/Wiley India/9788126525065 , Robotics /Appu/Wiley India/9789389583281 , Fuzzy Sets And Fuzzy Logic With Engineering Applications, 4Ed, An Indian Adaptation /Rose/Wiley India/9788126502608 , Natural Language Processing/Kumar/Wiley India/9789389307597 , Optimization Techniques /Malik/Wiley India/9789389698725 , Artificial Intelligence For Dummies/Mueller/Wiley India/9788126576104 , Big Data Analytics Using Artificial Intelligence Technologies /Dixit/Wiley India/9789391029685 , Artificial Intelligence: Concepts And Applications /Goel/Wiley India/9788126519934 , Artificial Intelligence: Making A System Intelligent /Jain/Wiley India/9788126579945 , Artificial Intelligence/Kumar/Wiley India/9789389795134 , Process Dynamics And Control, 4Edan Indian Adaptation /Seborg/Wiley India/9789354248429 , Digital Control/Moudgalya/Wiley India/9788126522064 , An Advanced Approach To Data Interpretation For Competitive Examinations/R.S. Aggarwal/S Chand Publishing/978-9358702330 , Quantitative Aptitude For Competitive Examinations/R.S. Aggarwal/S Chand Publishing/978-9355012326 , Modern Approach To Verbal & Non-Verbal Reasoning/R.S. Aggarwal/S Chand Publishing/978-9355011534 , Objective General English/R.S. Aggarwal/S Chand Publishing/978-9355015075 , The Magic Of The Lost Temple/Sudha Murty/Penguin Books India/978-0143333166 , Samsara: Enter The Valley Of The Gods/Saksham Garg/Penguin/978-0143458289 , The Mountain Is You: Transforming Self-Sabotage Into Self-Mastery/Brianna Wiest/Amaryllis/978-9355434142 , I Dont Love You Anymore: Moving On And Living Your Best Life/Rithvik Singh/Ebury Press/978-0143469131 , Ancient India/Rs Sharma/Old Ncert/N/A , History Of Medieval India/Satish Chandra/Old Ncert/N/A , A Brief History Of Modern India/Spectrum Publications/Spectrum/N/A , India’S Struggle For Independence/Bipan Chandra/Penguin/N/A , Certificate Physical And Human Geography/G.C. Leong/Oxford University Press/N/A , India: A Comprehensive Geography/D.R. Khullar/Kalyani Publishers/N/A , Indian Polity/M. Laxmikanth/Mcgraw Hill/N/A , Indian Economy/Ramesh Singh/Mcgraw Hill/N/A , Environment/Shankar Ias/Shankar Ias Academy/N/A , Indian Art And Culture/Nitin Singhania/Mcgraw Hill/N/A , Disaster Management/R. Subramanian/Vikas Publishing/N/A , Internal Security/M.Karthikeyan/Tata Mcgraw Hill/N/A , Lexicon For Ethics, Integrity & Aptitude/Niraj Kumar/Pearson/N/A , Ethics, Integrity, And Aptitude/Subba Rao And P.N. Roy Chowdhury/Access Publishing/N/A , Principles Of Mathematical Analysis/Walter Rudin/Mcgraw-Hill Education/978-0070856134 , Real And Complex Analysis/Walter Rudin/Mcgraw Hill Education/978-0070619876 , Functional Analysis/Walter Rudin/Mcgraw Hill Education/978-0070619883 , Mathematical Analysis/Tom M. Apostol /Narosa/978-8185015668 , Real Analysis/Royden/Pearson Education India/978-9332551589 , Analysis I/Terence Tao/Hindustan Book Agency/978-9380250649 , Complex Analysis/Ahlfors L V/Mcgraw Hill/978-1259064821 , Complex Variables And Applications/James Ward Brown, Ruel V. Churchill/Mcgraw Hill/978-9354600364 , Functions Of One Complex Variable I/John B. Conway/Springer/978-0387903286 , Algebraic Topology/Allen Hatcher /Cambridge University Press/978-0521795401 , Topology/James Munkres/Pearson Education/978-9353432775 , Introduction To Topology And Modern Analysis /George Simmons/Mcgraw Hill Education/978-0070597846 , Introduction To Analytic Number Theory/Tom M. Apostol /Springer/978-1-4419-2805-4 , Topology Of Metric Spaces/S. Kumaresan/Narosa/978-81848705 , Topics In Algebra/I.N. Herstein/Wiley/978-8126510184 , Algebra/M Artin/Pearson Education India/978-9332549838 , Abstract Algebra/David S. Dummit, Richard M. Foote/Wiley/978-8126532285 , A First Course In Abstract Algebra/J.B. Fraleigh/Narosa Publishing House Pvt Ltd/978-8185015705 , Contemporary Abstract Algebra/Joseph A Gallian/Cengage India Private Limited/978-9353502522 , Linear Algebra/Kenneth M Hoffman And Ray Kunze/Prentice Hall India Learning Private Limited/978-9332550070 , Matrix Analysis/Roger A. Horn, Charles R. Johnson/Cambridge University Press/978-0521548236 , Topics In Matrix Analysis/Charles R. Johnson, Roger A. Horn/Cambridge University Press/978-0521467131 , Matrix Analysis/Rajendra Bhatia/Springer/978-0387948461 , Introduction To Linear Algebra/Gilbert Strang /Wellesley-Cambridge Press/978-09802327-7-6 , Linear Algebra And Learning From Data/Gilbert Strang/Wellesley-Cambridge Press/978-06921963-8-0 , Linear Algebra: A Geometric Approach/S. Kumaresan/Prentice Hall India Learning Private Limited/978-8120316287 , Differential Equations/Shepley L. Ross /Wiley/978-8126515370 , Theory Of Ordinary Differential Equations/Earl Coddington, Norman Levinson/Mcgraw Hill Education/978-0070992566 , Differential Equations: Theory - Technique And Practice /George Simmons/Mcgraw Hill Education/978-0070616097 , Introduction To Graph Theory/West/Pearson Education India/978-9332549654 , Graph Theory/Frank Harary/Narosa Publishing House/978-8185015552 , Spectral Graph Theory/Fan R. K. Chung/American Mathematical Society/978-0821803158 , Graphs And Matrices/Ravindra B. Bapat/Springer London Ltd/978-1848829800 , Spectra Of Graphs/Andries E. Brouwer, Willem H. Haemers/Springer/978-1489994332 , The Feynman Lectures On Physics Vol 3/Richard P. Feynman/Addison-Wesley/978-8185015842 , Quantum Computation And Quantum Information/M. A. Nielsen And I. L. Chuagn/Cambridge University Press/978-1107619197 , Principles Of Quantum Computation And Information: A Comprehensive Textbook/Giuliano Benenti, Giulio Casati/World Scientific Publishing Co Pte Ltd/978-9813279995 , Quantum Computing Explained/David Mcmahon/Wiley-Ieee Computer Society Pr/978-0470096994 , Coding Theory: A First Course/San Ling/Cambridge English/978-1108717540 , Elements Of Information Theory/Joy A. Thomas Thomas M. Cover/Wiley/978-8126541942 , First Course In Information Theory/Raymond W. Yeung/Springer Low Price Edition/978-8184897036 , Machine Learning: A Probabilistic Perspective/Kevin P. Murphy /The Mit Press/978-0262018029 , Introduction To Data Mining/Pang-Ning Tan Michael Steinbach Anuj Karpatne Vipin Kumar/Pearson/978-9354491047 , Data Warehousing: Fundamentals For It Professionals/Paulraj Ponniah/Wiley/978-8126537297 , An Introduction To Probability Theory And Its Applications Vol I/William Feller/Wiley/978-8126518050 , An Introduction To Probability Theory And Its Applications Vol Ii/William Feller/John Wiley & Sons Inc/978-8126518067 , A Textbook Of Algebra/Sudesh K Shah, Subhash Chand Garg/S.Chand/978-9352710829 , Introduction To Differential Geometry Of Space Curves And Surfaces/Taha Sochi/Create Space/1546735895 , Differential Geometry Of Manifolds/U. C. De, A. A. Shaiks/Narosa Publisher/ 978-8173197772 , Differential Geometry Of Manifolds/Lovett Stephen/Taylor & Francis Ltd/978-0367180461 , Adventures In Stochastic Processes/Sidney I. Resnick/Springer Science & Business Media/978-1461203872 , Statistical Methods/Kapil Sharma/Oxford Book Co./978-9350304693 , Statistics For Business And Economics/Dr. G.P. Yadav/Oxford Book Co./8185771545 , Statistics For Management /Ashish J. Dave/Oxford Book Co./978-9350300732 , Statistics For Management And Economics/Dr. G.P. Yadav/Oxford Book Co./978-8183765688 , Strategic Methods And Concepts Of Statistics/R.K. Jacob/Oxford Book Co./978-8183765800 , Vector Calculus/Dr. Rakesh Kumar Pandey/Oxford Book Co./978-9350304716 , A Course Of Mathematical Analysis/P K Mittal & /S.Chand/978-8121904728 , A Textbook Of Algebra/Subhash Chand Garg /S.Chand/978-9352710829 , A Textbook Of Discrete Mathematics/Dr. Swapan Kumar Sarkar/S.Chand/9788121922326 , A Textbook Of Vector Analysis/P K Mittal & /S.Chand/9788121922432 , A Textbook On Dynamics/M Ray & G C Sharma/S.Chand/9788121903424 , Advanced Differential Equations/Dr. M.D. Raisinghania/S.Chand/9788121908931 , Analytical Solid Geometry/P K Mittal & Shanti Narayan/S.Chand/9788121926614 , Applied Mathematics/N C Srinivas & Ch V Ramana Murthy/S.Chand/9788121920827 , Differential Calculus/Shanti Narayan & P K Mittal/S.Chand/9788121904711 , Differential Calculus For Competetions/Shanti Narayan/S.Chand/978-8121925136 , Dynamics/Dr. M.D. Raisinghania/S.Chand/978-8121926492 , Elementary Statistics/H C Saxena/S.Chand/978-8121909259 , Elements Of Real Analysis/Dr. M.D. Raisinghania & Shanti Narayan/S.Chand/9788121903066 , Experimental Statistics/Dr. K. Balaji/S.Chand/9788121935661 , Fourier Series And Integral Transforms/Dr. V. Ramesh Babu & S. Ranganatham/S.Chand/9789384319090 , Integral Calculus/P K Mittal & Shanti Narayan/S.Chand/9788121906814 , Integral Calculus For Competetion/P K Mittal & Shanti Narayan/S.Chand/9788121925358 , Integral Equations And Boundary Value Problems/Dr. M.D. Raisinghania/S.Chand/9788121928052 , Mathematical Statistics/J. N. Kapur & H.C. Saxena/S.Chand/9788121912464 , Mathematics For Degree Students/Dr. U.S. Rana/S.Chand/9788121941013 , Algebraic Topology: An Introduction/Naseer Khan/Oxford Book Co./978-9350303344 , Analysis On Manifolds: A Modern Approach To Mathematics & Physics/V.G. Gupta/Oxford Book Co./978-9350304242 , Applied Combinatorics /Luis J. Green/Oxford Book Co./978-9350304556 , Applied Partial Differential Equations/Dr. F.D. Wade/Oxford Book Co./978-8189473433 , Applied Statistics For Economics And Business/G.P. Gupta/Oxford Book Co./978-9350303825 , Basics Of Bioinformatics/Narayan Dubey/Oxford Book Co./978-9383096893 , Business Statistics For International Trade/Ashish J. Dave/Oxford Book Co./978-9383101030 , Calculus For Computer Graphics/Gopal Narayan/Oxford Book Co./978-9383096916 , Calculus With Vectors/Luis J. Green/Oxford Book Co./978-9383096053 , Computing Fundamentals/Gopal Narayan/Oxford Book Co./978-9350304624 , Elementary Bioinformatics/Dr. Satish Kumar Sinha/Oxford Book Co./978-9350304266 , Environmental Statistics With R/Dr. Manendra Kumar/Oxford Book Co./978-9350301333 , Essential Statistics For Business And Economics/Ashish J. Dave/Oxford Book Co./978-9383096176 , Essentials Of Bioinformatics/Dr. Ashish Gulwe/Oxford Book Co./978-9350303603 , Fuzzy Logic, Neural Network And Genetic Algorithms Handbook/Jan Bundschuh/Oxford Book Co./978-9383096039 , Handbook Of Bioinformatics/S.G. Sandhu/Oxford Book Co./978-8193470404 , Mathematical Logic/Dr. Savita Mishra/Oxford Book Co./978-9350304532 , Mathematical Modelling/Naseer Khan/Oxford Book Co./978-9382629733 , Mathematical Physics/Hilary D. Brewster/Oxford Book Co./978-9350303412 , Optimization Theory: Techniques Of Operation Research/V.G. Gupta/Oxford Book Co./978-9350304334 , Mechanics/Muthamizh Jayapragasam, Laxmi Duraipandian/S.Chand/9788121902724 , Ordinary And Partial Differential Equations/Dr. M.D. Raisinghania/S.Chand/9788121908924 , Probability And Quening Theory/P Kandasamy & /S.Chand/9788121923569 , Theory Of Functions Of A Complex Variable/P K Mittal & Shanti Narayan/S.Chand/9788121906395 , Vector Algebra/P K Mittal & Shanti Narayan/S.Chand/9788121909525 , Vector Analysis/Kayalal Pachaiyappa & P Duraipandian/S.Chand/9789384319694 , Statics/Md Motiur Rahman/New Central Book Agency Pvt. Ltd./978-8173810275 , Rigid Dynamics/Md Motiur Rahman/New Central Book Agency Pvt. Ltd./978-8173812248 , Higher Algebra[Classical And Modern]/Ram Krishna Ghosh/New Central Book Agency Pvt. Ltd./978-8173811043 , Numerical Analysis With Elements Of Computer Science/Apurba Narayan Das/New Central Book Agency Pvt. Ltd./978-8173817557 , Mathematical Analysis/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./978-8173817809 , Numerical Analysis/Kalyan Mukherjee/New Central Book Agency Pvt. Ltd./978-8173815201 , Linear Programming And Theory Of Games/Pyari Mohan Karak/New Central Book Agency Pvt. Ltd./978-8173814051 , Analytical Geometry And Vector Algebra/Ratan Mohan Khan/New Central Book Agency Pvt. Ltd./9788-173810169 , Analytical Dynamics Of A Particle Including Elements Of Statics/Shambhunath Ganguly/New Central Book Agency Pvt. Ltd./9788-173811630 , Differential Equations With Introduction To Laplace Transform/Apurba Narayan Das/New Central Book Agency Pvt. Ltd./978-8173816635 , Numerical Methods Practical/Shyamapada Dutta/New Central Book Agency Pvt. Ltd./978-8173815645 , A First Course On Operations Research And Information Theory/Sanat Kumar Mazumder/New Central Book Agency Pvt. Ltd./978-8173818844 , Advanced Business Mathematics And Statistics/Ram Krishna Ghosh/New Central Book Agency Pvt. Ltd./978-8173816741 , Engineering Mathematics/Rajkumar Roychoudhury/New Central Book Agency Pvt. Ltd./978-8173810909 , Analytical Dynamics Of A Particle/Sambhunath Ganguly/New Central Book Agency Pvt. Ltd./978-8173810497 , Integral Calculus/Kantish Ch Maity/New Central Book Agency Pvt. Ltd./97-88173817328 , Introduction To Number Theory/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./97881-73815867 , Mathematics And Statistics/Suranjan Saha/New Central Book Agency Pvt. Ltd./97881-73811838 , Mathematical Probability/Kartick Chandra Pal/New Central Book Agency Pvt. Ltd./978-8173817816 , Differential Geometry/Fr F Goreux/New Central Book Agency Pvt. Ltd./978-8173815669 , Introduction To Tensor Calculus/Fr F Goreux/New Central Book Agency Pvt. Ltd./9788-173818516 , Vector Analysis Tensor Analysis And Linear Vector Space/S P Kuila/New Central Book Agency Pvt. Ltd./9789-352550333 , Introduction To Discrete Mathematics/M K Sen/New Central Book Agency Pvt. Ltd./97881-87134886 , Topics In Mathematics/Sandip Banerjee/New Central Book Agency Pvt. Ltd./97881-87134466 , Advanced Linear Programming & Game/A Mukherjee/New Central Book Agency Pvt. Ltd./97893-84294083 , Application Of Calculus/Debasish Sengupta/New Central Book Agency Pvt. Ltd./97881-87134626 , Analytical Statics/S A Mollah/New Central Book Agency Pvt. Ltd./97893-84294427 , Basic Concepts Of Numerical Methods, Probability And Statistics/Sandip Banerjee/New Central Book Agency Pvt. Ltd./97881-87134947 , Numerical Analysis And Computational Procedures/S A Mollah/New Central Book Agency Pvt. Ltd./97881-87134107 , An Introduction To Probability And Probability Distributions/Rajeshwar Singh/New Central Book Agency Pvt. Ltd./978938-4294175 , Dynamics Of Rigid Bodies/S A Mollah/New Central Book Agency Pvt. Ltd./978818-7134985 , Differential Geometry/M Majumdar/New Central Book Agency Pvt. Ltd./978938-4294144 , Advanced Higher Algebra/A N Das/New Central Book Agency Pvt. Ltd./978938-4294021 , Introduction To Abstract And Linear Algebra/Ajay Kumar Chaudhuri/New Central Book Agency Pvt. Ltd./97893-52550586 , Design Of Experiments And Sampling Methods/K C Bhuyan/New Central Book Agency Pvt. Ltd./97893-52550234 , Engineering Mathematics/T Veerarajan/Mcgraw Hill Education/ 97-0071328777 , Engineering Mathematics Ii/T Veerarajan/Mcgraw Hill Education/978-9387432345 , Advanced Engineering Mathematics/Ravish R. Singh/Mcgraw Hill Education/97-89353161033 , Discrete Mathematics/T Veerarajan/Mcgraw Hill Education/978-9353161606 , Business Mathematics And Statistics/N G Das, J. K. Das/Mcgraw Hill Education/978-0071333399 , A First Course In Mathematics For Management/M. Raghavachari/Mcgraw Hill Education/978-0070965706 , Fundamentals Of Mathematical Analysis/G. Das, S. Pattanayak/Mcgraw Hill Education/978-0074515730 , Introduction To Linear Algebra With Applications/James Defranza, Daniel Gagliardi/Mcgraw Hill Education/978-1259025587 , Numerical Methods With Programs In C/T Veerarajan, T Ramachandran/Mcgraw Hill Education/978-0070601611 , Ordinary And Partial Differential Equations With Laplace Transforms, Fourier Series And Applications/V. Sundarapandian/Khanna Publishers/978-1259004568 , Higher Engineering Mathematics/B.S. Grewal/Khanna Publishers/978-81-933284-9-1 , Discrete Mathematics And Its Applications/A. Tamilarasi And A.M. Natarajan/Khanna Publishers/978-81-7409-151-2 , Functions Of Complex Variables/A.K. Mukhopadhyay/Khanna Publishers/N/A , Numerical Methods In Engineering & Science With Programs In C, C++ & Matlab/B.S. Grewal/Khanna Publishers/978-81-7409-248-9 , An Introduction To The Calculus Of Variation For Engineers And Economics/A.K. Mukhopadhyay/Khanna Publishers/978-81-7409-186-4 , Engineering Mathematics/Mukul Bhatt/Mcgraw Hill Education India Pvt. Ltd/9789390000000 , Convective Heat And Mass Transfer/Adrian Bejan/John Wiley And Sons/978-0-470-90037-6 , Perspective In Environmental Studies/Anubha Kaushik And C P Kaushik/New Age International Publishers/978-93-86418-63-0 , Engineering Mechanics (Statics And Dynamics)/Dr D S Kumar/S K Karatia And Sons/978-93-5014-292-9 , Fundamentals Of Acoustics/Lawrence E. Kinsler, Austin R. Frey, Alan B. Coppens, James V. Sanders/Wiley/978-0-471-84789-2 , Foundations Of Engineering Acoustics/Frank Fahy/Academic Press/Elsevier/978-0122476655 , The Theory Of Sound, Volume I/Lord Rayleigh & Robert B. Lindsay/Dover Publications Inc./978-0486602929 , Mechanical Vibration/S.S. Rao/Pearson Education India/978-8177588743 , Vector Mechanics For Engineers: Statics And Dynamics/Beer, Johnston, Cornw Ell& Sanghi/Mcgraw Hill Education/978-1259062919 , Entrepreneurship Development And Small Business Enterprises/Charantimath Poornima M./Pearson/9353066263 , Entrepreneurial Development/Khanka S.S./S Chand/8121918014 , Mechanical Vibrations/Debabrata Nag/Wiley/978-8126530908 , Design Of Machine Elements/Dr.G.K.Vijayaraghav An&Dr.S.Vishnupriyan/Laxmi Publications/8192048535 , Introduction To Dynamics/Amitabha Ghosh/Springer/978-981-10-6094-6 , Mechanics Of Laminated Composite Plates And Shells – Theory And Analysis/J.N. Reddy/Crc Press/978-0203502808 , Composites: Science And Technology/Dr. R. C. Prasad, Dr. P. Ramakrishnan/New Age International (P) Ltd., Publishers/978-8122412512 , Product Design And Development/Karl Ulrich, Steven Eppinger And Maria C. Yang/Mc Graw Hill/978-1260043655 , Mechatronics: Integrated Mechanical Electronic Systems/K.P. Ramachandran, G.K. Vijayaraghavan, M.S.Balasundaram/Wiley India/978-8126518371 , Groovers Principles Of Modern Manufacturing Si Version/Mikell P. Groover/Wiley India/978-8126573059 , Manufacturing Science : Metal Cutting, Conventional And Non-Conventional Machine, Welding, Volume - Ii/G.S. Sawhney/Wiley India/97-89389520408 , Project Planning And Control With Pert And Cpm/Dr. B.C. Punmia, K.K. Khandelwal/Laxmi Publications (P) Ltd/978-8131806982 , Cad/Cam Theory And Practice/Ibrahim Zeid, R Sivasubramanian/Mcgraw Hill Education/978-0070151345 , Optimization For Engineering Design/Kalyanmoy Deb/Prentice Hall India Learning Private Limited/978-8120346789 , Mechanical Vibrations /G Kgrover/Nem Chand And Brothers /978-81-85240-56-5 , Tribology: Friction And Wear Of Engineering Materials /Ian Hutchings And Philip Shipway/Elsevier/978-0-08-100910-9 , Business Statistics: Text And Problems - With Introduction To Business Analytics/Nd Vohra/?Mcgraw Hill Education /978-9390727063 , Statistics For Management/Richard I. Levin, Masood H. Siddiqui, David S. Rubin, Sanjay Rastogi, /?Pearson Education/978-8184957495 , Financial Accounting/Sn Maheshwari, Suneel K Maheshwari,Sharad K Maheswari/?Vikas Publishing House/978-9352718535 , Management Accounting Principles & Practice/Shashi K. Gupta , R.K. Sharma, Neeti Gupta /Kalyani Publishers/N/A , Organizational Behaviour /Stephen P. Robbins, Timothy A. Judge , Neharika Vohra/?Pearson Education/978-9356064270 , Organisational Behaviour: Text, Cases & Games/K. Aswathappa/Himalaya Publishing House/978-93-5693-187-9 , Modern Microeconomics /A. Koustsoyiannis/?Palgrave Macmillan;/978-0333253496 , Business Law /Nd Kapoor /?Sultan Chand And Sons /978-9389174106 , Marketing Management /Phillip Kotler /?Pearson Education/978-9356062665 , Dominic Salvatore International Economics /Chandan Sharma /Wiley /978- 9354247170 , International Business /Charles W .L .Hill/?Mcgraw Hill/978-9355324771 , Strategic Management ( Concept & Cases )/Fred R David , Forest R David/Pearson Education/978-9332548930 , Production And Operations Management/Sn Chary/Mcgraw Hill/978-9353164812 , Production And Operations Management/E Anil Kumar , N Suresh/New Age International/978-8122421774 , E Commerce /Kenneth C. Laudon , Carol Guercio Traver/?Pearson Education/978-9356060647 , Entrepreneurship /Arya Kumar/Pearson Education /978-8131765784 , Corporate Finance /Ross , Westerfield ,Jaffe , Jordan /Mcgraw Hill /978-9390727926 , Security Analysis And Portfolio Management /Donald E. Fisher, Ronald J. Jordan, A.K . Pradhan /Pearson Education /978-9353066284 , Investment Analysis And Portfolio Management |/Prasanna Chandra /Mcgraw Hill /978-9354600074 , Advertising And Sales Promotion/Shh Kazmi, Satish Batra/Excel Books/978-8174466396 , Advertising And Sales Promotion ( An Integrated Marketing Communications Perspective)/George E Belch, , Michael A Belch, Keyoor Purani/Mcgraw Hill /978-9354600807 , Strategic Brand Management/Kevin Lane Keller , Vanitha Swaminathan, Ambi Mg Parameswaran , Issac C Jacob /Pearson Education /978-9353946135 , Human Resource Management: Text And Cases/ K. Aswathappa , Sadhna Dash/Mcgraw Hill /978-9355323675 , Managerial Economics And Business Strategy/Micheal R. Baye , Jeffery T . Prince/Mcgraw Hill/978-9354600203 , Intellectual Property Law/Avtar Singh/Eastern Book Company/978-9350289853 , Law Relating To Intellectual Property Rights/V K Ahuja/Lexis Nexis/978-8131251652 , Intellectual Property Rights Manual/Sumeet Malik/Eastern Book Company/978-9351452300 , Law Relating To Intellectual Property/Dr. B.L. Wadehra/Universal Law Publishing/978-9350350300 , Consumer Behavior/Kumar Leon G., Schiffman;Joe, Wisenblit;S. Ramesh/Pearson Education/978-9353069834 , Purchasing And Inventory Control/K S Menon And Sarita Kulkarni/ Shroff Publishers/978-8184047066 , Production Systems: Planning, Analysis, And Control/James L. Riggs /? John Wiley & Sons/? 978-0471847939 , A Textbook Ofmanufacturing Technology (Manufacturing Processes)/R K Rajput/ Laxmi Publications/? 978-8131802441 , A Textbook Of Material Science And Metallurgy /O P Khanna/Dhanpat Rai /978-8189928315 , Atomic Physics/Max Born (Author) , J. M. Radcliffe (Translated) R. J. B-. Stoyle (Translated)/Dover Publications/978-0486659848 , Concepts Of Atomic Physics/S P Kuila /New Central Book Agency (Ncba)/978-9352550838 , Fundamentals Of Molecular Spectroscopy/Banwell/Mcgraw Hill Education/978-9352601738 , Introduction To Nuclear And Particle Physics/V.K. Mittal, R.C. Verma, S.C. Gupta /Phi Learning/978-9387472617 , Concepts Ofnuclear Physics/Bernard Cohen/Mcgraw Hill Education/978-0070992498 , Nuclear And Particle Physics: An Introduction/B.R. Martin/Wiley/978-8126565078 , Introduction To Elementary Particle Physics/Alessandro Bettini/Cambridge University Press/978-1107050402 , Solid State Physics/Ashcroft, Mermin/Cengage Learning/978-8131500521 , Physics Of Semiconductor Devices/S.M. Sze, Kwok K. Ng /Wiley/978-8126517022 , Semiconductor Physics And Devices (Sie)/Donald Neamen (Author), Dhrubes Biswas/Mcgraw Hill Education/978-0071070102 , Liquid Crystal Sensors/Albert Schenning (Editor), Gregory P. Crawford (Editor), Dirk J. Broer (Editor)/Crc Press/978-1498729727 , Liquid Crystals: Experimental Study Of Physical Properties And Phase Transitions/Satyendra Kumar/Cambridge University Press/978-0521187947 , Liquid Crystals I/M.A. Athanassopoulou, M.A. Bates, Et Al./Springer/978-3662147160 , Dielectric Effect In The Isotropic Phase Of Liquid Crystal Materials/Mukherjee Prabir,Drozd-Rzoska Aleksandra,Rzoska Sylwester/Lambert Academic Publishing,/9783660000000 , Nanoscience With Liquid Crystals: From Self-Organized Nanostructures To Application/Quan Li/Springer/978-3319377124 , Fundamentals Of Mathematical Physics/A. B. Gupta/Books & Allied (P) Ltd/81-87134-23-2 , Higher Mathematical Physics/H. K. Das And Dr Rama Verma/S. Chand & Company Pvt. Ltd/978-93-83746-77-4 , Head Thermodynamics And Statistical Physics/Brij Lal, N. Subrahmanyam And P. S. Hemne/S. Chand & Company Pvt. Ltd/81-219-2813-3 , The Physics Of Solar Cells : Perovskites, Organics, And Photovoltaic Fundamentals/Juan Bisquert/Crc Press/9781138099968 , Nanomaterials And Nanocomposites: Synthesis, Properties, Characterization Techniques, And Applications/Rajendra Kumar Goyal/Crc Press/9781498761666 , Callisters Materials Science And Engineering./Balasubramaniam/Wiley India/9788126541607 , Introduction To Physics /Cutnell/Wiley India/9788126556021 , Physics, Vol 1, 5Ed , An Indian Adaptation /Halliday/Wiley India/9789354640384 , Physics, Vol 2, 5Ed, An Indian Adaptation /Halliday/Wiley India/9789354640438 , Principles Of Physics, 10Ed/Halliday/Wiley India/9788126552566 , Statistical Mechanics, 2Ed, An Indian Adaptation/Huang/Wiley India/9789354247736 , Classical Electrodynamics, An Indian Adaptation /Jackson/Wiley India/9789388991070 , Kittels Introduction To Solid State Physics, Wiley India Edition/Kittel/Wiley India/9788126578436 , Modern Physics, 4Ed, An Indian Adaptation /Krane/Wiley India/9789354244681 , Material Science: Nanotechnology And Applications /Kumar/Wiley India/9789390455317 , Introduction To Nanoscience And Nanotechnology, An Indian Adaptation /Poole/Wiley India/9789354240201 , Applied Solid State Physics/Rajnikant/Wiley India/9789354643309 , A Textbook Of Astronomy And Astrophysics /Sharma/Wiley India/9789389520903 , Tensors: Concepts And Applications With Scilab Programs/Soni /Wiley India/9789389633207 , Engineering Physics, As Per Aicte /Wiley Editorial Team/Wiley India/9788126521418 , A Textbook Of Applied Physics, Vol I/Jha/Wiley India/9789389307405 , A Textbook Of Applied Physics, Vol Ii/Jha/Wiley India/9789389520453 , Mathematical Methods In The Physical Sciences, 3Ed, An Indian Adaptation /Boas/Wiley India/9789354644252 , Fundamentals Of Fluid Mechanics/Sawhney/Wiley India/9789389698008 , Quantum Mechanics Concepts And Applications/Nouredine Zettili/Wiley India/978-0-470-02678-6 , Introductory Nuclear Physics/S. Krane Kenneth/Wiley India/978-8126517855 , Principles And Applications Of Ferroelectrics And Related Materials/M. E. Lines And A. M. Glass/Oxford University Press/978-0198507789 , A Modern Introduction To Quantum Field Theory/Michele Maggiore/Oxford University Press/978-0198520740 , The Physics Of Solids/J. B. Ketterson/Oxford University Press/978-0198742906 , Introduction To Spintronics/Supriyo Bandyopadhyay/Routledge/978-0367656447 , Perovskite Metal Oxide/Moharana/Elsevier/9780320000000 , Materials Characterization Techniques/Lin Li, Sam Zhang,Ashok Kumar/Crc Press/?978-1032064208 , Magnetic Measurement Techniques For Materials Characterization/Victorino Franco/Springer/978-3030704452 , Indentation Techniques In Ceramic Materials Characterization: Theory And Practice/Ahmad G.Solomah/Ceramics Transaction/978-1574982121 , Element Of X-Ray Diffraction/B D Cullity/Pearson Education India/9789332535169 , Introduction To Magnetic Materials/B D Cullity/Wiley-Ieee Press/978-0471477419 , Symmetry And Spectroscopy: An Introduction To Vibrational And Electronic Spectroscopy/Daniel C Harris/Dover Pubns/978-0486661445 , The Spectra And Structures Of Simple Free Radicals: Introduction To Molecular Spectroscopy/Gerhard Herzberg/Dover Pubns/978-0486658216 , An Introduction To Practical Infra-Red Spectroscopy/A D Cross/Dover Pubns/978-1489962744 , Handbook On The Physics And Chemistry Of Rare Earths: Optical Spectroscopy/Karl A.Gschneidner/North-Holland/978-0444521446 , Molecular Spectroscopy/Jackd.Graybeal/Mcgraw-Hill Education(Ise Edition)/978-0070243910 , Fundamentals Of Statistical And Thermal Physics/Frederick Reif/Sarat Book Distributors/9789380663142 , Thermodynamics And An Introduction To Thermostatistics/H. B. Callen/John Wiley & Sons Inc/9780471862567 , Introduction To Phase Transitions And Critical Phenomenon (International Series Of Monographs On Physics)/H. E. Stanley/Oxford University Press/9780195053166 , A Guide To Monte Carlo Simulations In Statistical Physics/David P. Landau And Kurt Binder/? Cambridge University Press;/9781139696463 , Statistical Mechanics/R. K. Pathria/Elsevier/9789351073970 , Computational Methods In Physics And Engineering/Samuel S M Wong/World Scientific/9810230435 , Mathematical Methods Of Physics/Jon Mathews And Robert L. Walker/?Pearson Addison-Wesley/805370021 , A Text Book Of Integrated Engineering Physics /Amal Chakraborty/Chhaya Prakashani Pvt Ltd/978-81-906486-1-5 , A Text Book Of Basic Engineering Physics/Amal Chakraborty/Chhaya Prakashani Pvt Ltd/978-8190648615
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 11
19.
Rural Development #9369129 Technical Bid
Tender For Constructing Liquid Waste Management Project At Rethre Bk. Tal Karad Dist Satara - LWM Under SBM Rethare Bk. Tq-Karad, Dist-Satara - Large Compost Pits 7 Nos- Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 2 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) 3 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) 4 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 5 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 6 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Leach Pit (3 Nos)- Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 8 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) 9 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) 10 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 11 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 12 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 13 Providing and fixing concreate manhole cover and light/medium/heavyduty with frame etc. complete. 14 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 15 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). Working Pressure 6 to 12.5 Kg./Sq.cm. 110 mm. 16 400 KLD STP- Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete 0.0 to 1.5 m 17 3.0 to 4.5 m 18 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 0.0 to 1.5 m 19 1.5 to 3.0 m 20 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) 1.5 to 3.0 m 21 3.0 to 4.5 m 22 Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) 3.0 to 4.5 m 23 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 24 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 25 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 26 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 27 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) c) Corrosion Resistant Steel (Fe 500) 28 Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) 29 Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer-in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 30 Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B .W .G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts , lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 31 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 32 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 33 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curingcomplete. 34 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 35 Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 36 Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. 37 Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 38 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 39 Transportation as per STATEMENT VI Including loading, unloading and stacking Earth (4.8 Cum) lead 15 Km 40 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 41 Fine and Coarse Screen (Manual) of size 1.65 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. 42 Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) 43 Erection 44 Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 3 HP (Up to 18000 LPH) 45 Erection 46 Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 3 HP (Up to 18000 LPH) 47 Erection 48 Pressure Sand Filter of FRP / MSEP vessel with suitable thickness to withstand a water pressure including MPV or 5 Valve system and PVC / UPVC / MSEP interconnecting and underdrain piping including fittings, with standard filter media layer with minimum depth of filter sand 1.0 m supported by gravels. The piping arrangement should provide sufficient pressure for backwash operations and avoid loss of sand during backwash operation. Suitable openings to be provided to ease addition and removal the media. Dia 1.7 m x 2 m minimum height 49 Activated Carbon Filter of FRP / MSEP vessel with suitable thickness to withstand a water pressure including MPV or 5 Valve system and PVC / UPVC / MSEP interconnecting and underdrain piping including fittings, with standard filter media layer with minimum depth of Activated Carbon 1.0 m supported by gravels.The piping arrangement should provide sufficient pressure for backwash operations and avoid loss of Activated carbon during backwash operation. Suitable openings to be provided to ease addition and removal the media. Dia 1.7 m x 2 m minimum height 50 NaOCl ChlorinatorPump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10LPH Power Source Electric - Phase Single Material PP / PTFE(Teflon) / Voltage 230 Volt / Frequency 50Hz / Mixing Tank of 25 Ltrs capacity- 1 No / Dosing Pump- 2 Nos 51 Providing & erecting floor/wall mounted MCCB panel board, with door, suitable for four pole incoming 250A, 2 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) 52 Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. > 7.5 HP & Up to 12.5 HP 53 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core 16 sq mm 54 Erection 55 Aluminium conductor 4 Core, XLPE / PVC insulated & armoured cable Supplying and erecting, XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 6 sq mm 56 Erection 57 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4 core 2.5 sq mm 58 Erection 59 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).Working Pressure 8 Kg/Sq.cm 63 mm. 60 PVC Specials- 10% 61 40mm 62 PVC Specials- 10% 63 75 mm. 64 PVC Specials- 10% 65 20 mm 66 PVC Specials- 10% 67 63 mm. 68 PVC Specials- 10% 69 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance fromstores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint). 63 mm. 70 75 mm. 71 Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 63 mm. 72 75 mm. 73 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Sluice valves - PN -1 (Without by pass) 65 mm. 74 65 mm. 75 Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984)Without by pass arrangement -PN -1 65 mm. 76 65 mm. 77 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of alllabour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.(Rate for all class of valves.) 65 mm. 78 Reflux valves (non-return valves ) 79 Supplying ofSpecially designed container for holding Bio media including mixture of cocohusk,bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. 80 Stone Aggregate - 40mm, 20 mm, 10 mm and 5 mm 81 Transportation as per STATEMENT VI Including loading, unloading and stacking Earth (4.8 Cum) lead 15 Km 82 Additional Sump-Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to allexpose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. Anti-termite treatment shall be given for underground portion of the structure.MJP/ SSR/Corrigendum No.8/2021-22/SECTION - K : RCC GSR Item No.1 / Page no.8dated on 10/03/2022 83 Addition of 7.5% Raft Foundation 84 Addition of 5% Seismic zone 85 Addition of 5% sugar cane area 86 Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 3 HP (Up to 18000 LPH) MJP/SSR/EM/22-23/Item No. PM 9-1-1/Page No. 4,5 87 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 110 mmMJP/ SSR/Corrigendum No. 10 /21-22/SECTION -P.V.C. PIPES, Page no.3 dated 18/07/2022 88 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
20.
Rural Development #9342236 Technical Bid
Tender For Solid And Liquid Waste Management Work In Village Jalgaon Block Dapoli District Ratnagiri, 1 SUB ESTIMATE NO.1 Leach Pit with Inlet Chember- 10 KLD 2 Item No.1: Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259)LIFT 0.0 to 1.5 M 3 Item No.2:Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) Excavation work (0.0-1.5 M) 4 Item No.3: Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in- charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) 5 Item No. 4 :Providing and laying in situ Cement Concrete M-15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No.-Bd E/1 Page No. 287 and B-7, Page No. 38 6 Item No 5: Providing second class Burnt Brick masonry with conventional/ 1.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 7 Item No 6: Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 8 Item No 7:Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). With fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan Mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). 9 Item No 8:Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 10 Item No.9 : Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 11 Item No.10 : Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 12 SUB ESTIMATE NO.2 Plastic Waste Storage Cage 13 Item No.11: Providing and fixing crimped with G.I. mesh and size 20mmx20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc. complete (excluding cost of structural steel) 14 Item No.12:Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (248.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.).. 15 Item No. 13: Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted /bolted/welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. 16 SUB ESTIMATE NO.3:Design For NADEP Tank 17 Item No.14: Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 18 Item No.15:-Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 19 Item No.16:- Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in- charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) 20 Item No.17:- Providing dry trap/granite/quartzite/gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 21 Item No.18:- Providing and laying in situ Cement Concrete M-15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. - Bd E/1 Page No. 287 and B-7, Page No. 38 22 Item No.19: Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 23 Item No.20:Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete 24 Item No.21:Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete 25 SUB ESTIMATE NO.4:Tiger Bio Filter of 50 KLD Capacity 26 Item No.22:Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 27 0.0 to 1.5 m 28 1.5 to 3.0 m 29 3.0 to 4.5 m 30 4.5 to 6.0 m 31 Item No 23: Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 32 0.0 to 1.5 m 33 1.5 to 3.0 m 34 3.0 to 4.5 m 35 4.5 to 6.0 m 36 Item No.24:Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in- charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) 37 0.0 to 1.5 m 38 1.5 to 3.0 m 39 3.0 to 4.5 m 40 4.5 to 6.0 m 41 Item No.25: Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) 42 0.0 to 1.5 m 43 1.5 to 3.0 m 44 3.0 to 4.5 m 45 4.5 to 6.0 m 46 Item No.26:Providing dry trap/ granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers Including hand packing and compacting, etc. complete (Bd-A-12/264) 47 Item No.27: Providing and laying in situ Cement Concrete M-15 al trap/ granite quartzite/greiss metal for foundation and bedding including baling out water, form work, Compaction, curing, etc complete (Cement 5.90 bags/cum) Spec No Bd E/1Page No. 287 and B-7. Page No.38 48 Item No.28: Providing and laying in situ Cement Concrete of trap/ granite/quartzite/gneiss metal for RCC work in foundation like raft, grillage, strip foundation and fooling of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 49 Item No.29:Providing and casting in situ C.C. of trap/granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Biria Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 50 Item No.30:Providing and casting in situ C.C. of trap/granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, AC.C. Ambuja, Biria Gold, Manikgad, Rajashree, otc cement is permitted.) (Excluding M.S. or Tor reinforcement) 51 Item No.31:Providing and casting in situ C.C. of trap/granite/Quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as dinscted by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM. 1:3 of sufficient minimum 10 thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T. ACC, Anbuja, Birta Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S or Tor reinforcement) 52 Item No.32: Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306)Corrosion Resistant Steel (Fe500) 53 Item No.33: Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including 12 necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete (Bd-U-1/537) 54 Item No.34: Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer- in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 55 Item No.35:Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (248.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 56 Item No.36: Providing fly ash brick masonry with conventional/I.S type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 57 Item No.37: Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 58 Item No.38: Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 59 Item No.39: Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 60 Item No.40:Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 61 Item No 41:Dewatering the excavated trenches and pools of water in the building trenches/ pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 62 Item No 42:Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 63 Item No.43:Transportation as per STATEMENT VI Including loading, unloading and stacking Earth (4.8 Cum) lead 15 Km 64 Item No.44:Electromechnical ItemsScreen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm 55 rod of total length 200 mm straight and 50 mm of 90 degree bend. Market Rate 65 Item No.45: Grit pumpSupplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) 66 Item No 46: Raw Sewage PumpsSupplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below1 HP (Up to 9000 LPH) 67 Item No 47:NaOCI Chlorinator Pump Diaphragm Type/peristaltic type/Solenoid MaxFlow Rate Upto 10LPH Power Source ElectricMaterial PP/PTFE (Teflon)Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity- 1 No Dosing Pump-2 nos Market Rate 68 Item No.48:Control Panel Designing, Supplying, Installing, commissioning & testing of PLC Panel. Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. 69 Item No.49: Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380-440 Volt, 3 phase, 50 Hz with no volt coll, over load element, and ON-OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser.>7.5 HP & Up to 12.5 HP 70 Item No 50:Main power supply cable3 core PVC Insulated, PVC sheathed copper conductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC Insulated, and PVC sheathed.3 core 16 sq mm 71 Item No.51: Power cablesAluminium conductor 4 Core, XLPE/PVC insulated & armoured cable Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid/stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner. 4 Core 6 sq mm 72 Item No.52: Control Cables Copper conductor PVC insulated, Unarmoured control cableSupplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner.4 Core 2.5 sq mm 73 Item No 53: Plumbing items Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading. conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).1) 10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. 2) One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates below. 74 Main header 75 63 mm. 76 PVC Specials-10% 77 Distribution 78 63 mm. 79 PVC Specials-10% 80 TBF outlet collection 81 Main header 82 63 mm. 83 PVC Specials-10% 84 collection tributory 85 63 mm. 86 PVC Specials-10% 87 TBF distribution 88 63 mm. 89 PVC Specials-10% 90 Item No.54: Labour 91 Plumber 92 Helper 93 Item No.55:Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Sluice valves-PN-1 (Without by pass)Raw Sewage pump65 mm. 94 Item No 56:Providing and supplying ISI mark CI D/F reflux valves (non-return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.S.5312 Part I (1984)Without by pass arrangement -PN-1Raw Sewage pump 65 mm. 95 Item No.57: Bio media ItemsSupplying of Specially designed container for holding Filter media including Lightweight Expanded Clay Aggregates size (8-30 mm) and Bio media including mixture of woodchips Vermicompost, cocopeat and bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. Market Rate 96 Item No.58:Rapid sand Gravity filter sand At Source (Godhara, Gokak, Kanhan, Yesagi sand) 97 Item No.59: Trasnsportation Godhara to Pune distance by Road 660 Km. 98 Item No.60: Stone Aggregate 20 mm 99 Item No.61: Transportation as per STATEMENT VI Including loading, unloading and stacking Manure or sludge (5.52 Cum) lead 25 Km 100 Item No.62:Detailed Process Designing, Technology charges and commissioning of Sewage Treatment Plant (STP) based on Tiger Bio Filter (TBF) technology as turnkey job 101 SUB ESTIMATE NO.5: Tiger Bio Filter of 25 KLD Capacity 102 Item No.63:Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 103 0.0 to 1.5 m 104 1.5 to 3.0 m 105 3.0 to 4.5 m 106 4.5 to 6.0 m 107 Item No 64: Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 108 0.0 to 1.5 m 109 1.5 to 3.0 m 110 3.0 to 4.5 m 111 4.5 to 6.0 m 112 Item No.65:Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in- charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) 113 0.0 to 1.5 m 114 1.5 to 3.0 m 115 3.0 to 4.5 m 116 4.5 to 6.0 m 117 Item No.66: Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) 118 0.0 to 1.5 m 119 1.5 to 3.0 m 120 3.0 to 4.5 m 121 4.5 to 6.0 m 122 Item No.67:Providing dry trap/ granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers Including hand packing and compacting, etc. complete (Bd-A-12/264) 123 Item No.68: Providing and laying in situ Cement Concrete M-15 al trap/ granite quartzite/greiss metal for foundation and bedding including baling out water, form work, Compaction, curing, etc complete (Cement 5.90 bags/cum) Spec No Bd E/1Page No. 287 and B-7. Page No.38 124 Item No.69: Providing and laying in situ Cement Concrete of trap/ granite/quartzite/gneiss metal for RCC work in foundation like raft, grillage, strip foundation and fooling of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 125 Item No.70:Providing and casting in situ C.C. of trap/granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Biria Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 126 Item No.71:Providing and casting in situ C.C. of trap/granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, AC.C. Ambuja, Biria Gold, Manikgad, Rajashree, otc cement is permitted.) (Excluding M.S. or Tor reinforcement) 127 Item No.72:Providing and casting in situ C.C. of trap/granite/Quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as dinscted by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM. 1:3 of sufficient minimum 10 thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T. ACC, Anbuja, Birta Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S or Tor reinforcement) 128 Item No.73: Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306)Corrosion Resistant Steel (Fe500) 129 Item No.74: Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including 12 necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete (Bd-U-1/537) 130 Item No.75: Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer- in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 131 Item No.76:Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (248.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 132 Item No.77: Providing fly ash brick masonry with conventional/I.S type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 133 Item No.78: Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 134 Item No.79: Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 135 Item No.80: Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 136 Item No.81:Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 137 Item No 82:Dewatering the excavated trenches and pools of water in the building trenches/ pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 138 Item No 83:Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 139 Item No 84:Transportation as per STATEMENT VI Including loading, unloading and stacking Earth (4.8 Cum) lead 15 Km 140 Item No.85:Electromechnical ItemsScreen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm 55 rod of total length 200 mm straight and 50 mm of 90 degree bend. Market Rate 141 Item No.86: Grit pumpSupplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) 142 Item No 87: Raw Sewage PumpsSupplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below1 HP (Up to 9000 LPH) 143 Item No 88:NaOCI Chlorinator Pump Diaphragm Type/peristaltic type/Solenoid MaxFlow Rate Upto 10LPH Power Source ElectricMaterial PP/PTFE (Teflon)Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity- 1 No Dosing Pump-2 nos Market Rate 144 Item No.89:Control Panel Designing, Supplying, Installing, commissioning & testing of PLC Panel. Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. 145 Item No.90: Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380-440 Volt, 3 phase, 50 Hz with no volt coll, over load element, and ON-OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser.>7.5 HP & Up to 12.5 HP 146 Item No 91:Main power supply cable3 core PVC Insulated, PVC sheathed copper conductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC Insulated, and PVC sheathed.3 core 16 sq mm 147 Item No.92: Power cablesAluminium conductor 4 Core, XLPE/PVC insulated & armoured cable Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid/stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner. 4 Core 6 sq mm 148 Item No.93: Control Cables Copper conductor PVC insulated, Unarmoured control cableSupplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner.4 Core 2.5 sq mm 149 Item No 94: Plumbing items Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading. conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).1) 10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. 2) One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates below. 150 Main header 151 63 mm. 152 PVC Specials-10% 153 Distribution 154 63 mm. 155 PVC Specials-10% 156 TBF outlet collection 157 Main header 158 63 mm. 159 PVC Specials-10% 160 collection tributory 161 63 mm. 162 PVC Specials-10% 163 TBF distribution 164 63 mm. 165 PVC Specials-10% 166 Item No.33: Labour 167 Plumber 168 Helper 169 Item No.95:Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Sluice valves-PN-1 (Without by pass)Raw Sewage pump65 mm. 170 Item No 96:Providing and supplying ISI mark CI D/F reflux valves (non-return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.S.5312 Part I (1984)Without by pass arrangement -PN-1Raw Sewage pump 65 mm. 171 Item No.97: Bio media ItemsSupplying of Specially designed container for holding Filter media including Lightweight Expanded Clay Aggregates size (8-30 mm) and Bio media including mixture of woodchips Vermicompost, cocopeat and bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. Market Rate 172 Item No.98:Rapid sand Gravity filter sand At Source (Godhara, Gokak, Kanhan, Yesagi sand) 173 Item No.99: Trasnsportation Godhara to Pune distance by Road 660 Km. 174 Item No.100: Stone Aggregate 20 mm 175 Item No.101: Transportation as per STATEMENT VI Including loading, unloading and stacking Manure or sludge (5.52 Cum) lead 25 Km 176 Item No.102:Detailed Process Designing, Technology charges and commissioning of Sewage Treatment Plant (STP) based on Tiger Bio Filter (TBF) technology as turnkey job
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Maharashtra View Result →
21.
Defence #8650981 AOC
Tender For Special Repair To Bldg No P-269 And P-271 In The Aor Of Age B/R-I Under Ge 969 Ews(Job No: (I) W/Spl Repair (Bldg)/35/19 Inf Div Camp/2025-26 & (Ii) W/Spl Repair (Bldg)/36/19 Inf Div Camp/2025-26); 1 Dismantling of plain or corrugated steel sheeting , any gauge and thickness in roof covering including Nainital or similar pattern roof covering complete all as specified. 2 M&L Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550MPa as, in roofs, walls etc complete all as specified 3 M&L Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550MPa as, in roofs, walls etc. complete all as specified 4 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets,any thickness, cover fillets etccomplete all as specified. 5 M&L 4 mm thick veneered decorative, plywoodgrade 1 (BWR resin) with decorative face veneers on one faces , fixed with nails to timber frame work on ceiling. all as specified and directed. 6 M&L 4 mm thick veneered decorative, plywoodgrade 1 (BWR resin) with decorative face veneers on one faces , fixed with nails to timber frame work on wall. all as specified and directed. 7 Dismantling of timber scantling 40 Sqcmand over in section in any position in unframed work. all as specified and directed. 8 M&L for second class soft wood (Kail) clean swan timber fixed in scantling. all as specified and directed. 9 Dismantling of timber fillets rails, posts rafter purlins etc under 40 Sqcm in section in any position in framed workall as specified and as directed 10 S&F second classsoftwoodplain fillets square, rectangular in section exc 13 Sqcm & not exc 25 Sqcm complete all as specified and directed. 11 S&F second classsoftwoodplain fillets square, rectangular in section exc6 Sqcm and not exc 13 Sqcm complete all as specified and directed. 12 Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified. 13 Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified. 14 M&L non-skid ceramic tiles7 to 8mm thick area of each tiles exc 0.18m and n.exc 0.38 Sqm in floor etc,Incl screed bed 15 mm thick in CM 1:6 complete all as specified and directed 15 S&F glazed ceramic coloured tiles in vernicles surfaces of size 600x300x7/9 mm thick set and jointed in neat cement slurry and pointedwhite or coloured cement to match tile surface over and including 10 mm thick plaster in cement and sandmortar 1:4, complete all as specified. 16 M&L for 25mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floors finished even and fair. 17 M&L forKota stone slabs, 20mm to 25mm thick, machine cut as in flooringof size not less than 0.25 Square metre each, set and jointed in cement slurry and pointed in cement mixed with pigment to match the shade of slab laid over & including screed bed of 15 mm thick in cement mortar 1:4including rubbing, cutting and polishing (mirror type), complete all as specified. 18 M&L 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement ,complete all as specified. 19 Taking down chowkhats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed 20 Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm each with shutters(W/out taking off shutters from the frames). complete all as specified 21 S&F 2nd Class Soft wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified and as directed 22 S&F 2nd class Hard wood 35mm thick factory made panelled shutters with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 (Pt-I) kiln seasoned and chemically pressure treated. complete all as specified 23 S/F PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing sown in SSR Part II, complete all as specified. 24 S&F factory made solid PVC moulded door shutter28 to 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heatmoulded plain colour PVC C channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & and as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to thethe stiles & rails with suitable PVC sheet beading, and joined together with solvent cementcomplete all as shownin drawing of relevant item in MES, schedule Part II, 2010 as specified. 25 S&F aluminium alloypowder coated aluminium sliding windows three track with movable shutters (sliding on minimum two PVC roller of best quality, for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and incl 5.50mm thick glass & stainless steel wire mesh fixed with neoprene rubber gasket with aluminium beading clips, frame made with aluminium section as appended below :-(a) Window Frame- 75mmx35mmx1.48mm thick(b) Top/Bottom rail and style/rail of shutter - 38mmx19mmx1.48mm thick and over(c) Aluminium beading /clips - 0.7mm thick(d) Stainless Steel wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed in aluminium window or alongwith F/Y section fixed with aluminium fire staples complete.(e)Aluminium fittings such aluminium suitable handle with auto interlocking closing.(f) Making good of wall surfaces to match with existing surfaces complete all as specified and directed. 26 MS cold rolled butt hinges medium weight 100 mm long complete all as specified. 27 S&F 300mm long Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy all as specified and as directed. 28 S&F 300 mm size mild steel ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and directed. 29 S&F 200mm long Anodised Aluminium tower bolt all as specified 30 S&F Sheet glass ordinary quality & glazing with oil putty in square n-exc. 0.5 sqm in each pane 3mm thick complete all as specified & directed. 31 M/L for applying two coats of synthetic enamel paint over a coat of pinkprimer including preparation of new wooden or wood based surfaces over 10cm width or girthetc all as specified and directed. 32 M&L for Waterproofing and repair of leakage/seepage treatment to external wall complete all as specified and directed :- (a) Step 1 - Taking down cement plaster of any descriptionby manual and mechanical means, plumbing treatment of pipesetc including racking out joints hacking for key, scrubbing down with water etc. and (b) Step 2 - applying waterproofing treatment to slab/ wall area with assign paints smart careDamp Block 2k @1.5kg/sqm, Damp block 2k is atwo component elastomeric cementations coating conforming to ASTM D 412 & ASTM D 4548.5 standards including all necessary surface preparation, etc. complete as per manufacturers specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1.0mm. The coating shall have a 100% elongation and crack bridging upto 1.2mm as per ASTM D4548.5. (c) Step 3- Over and above Asian Paints Smart care Damp block 2k applying plaster minimum 12mm thick. SC REPAIR MORTAR.Makes ( BASF, Asian Paints, Sika, Fosroc) 33 Demolition of brick work, PCC block masonry, stone masonry or boulder masonry built in cement mortar complete all as specified and directed. 34 M&L for brick work with sub class B bricks (Old size) straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified 35 M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 complete all as specified and directed. 36 M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 37 M&L for preparation of new surfaces of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paintcomplete all as specified as directed by Engr-in-Charge. 38 M&L for complete removal of existing treatment on old wall surfaces & finishing walls with acrylic smooth exterior paint of required shade Now work (two or more coat applied @ 1.67 Itr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) new surfaces or old decorated surfaces complete all as specified and directed. 39 M&L for preparation of old treated surface of brick/stone work, concrete plastered or unplastered surface and applying two coat of OBD on walls all as specified. 40 Demolition of reinforced concrete of any description and in any position not otherwise specifically provided complete all as specified. 41 M&L for mild steel TMT Bars 10mm dia and over, quality, cut to length, bent to shape required including cranking, bending and binding with mild steel wire (annealed) not less than 0.9 mm dia. 42 M&L1:2:4, type B1 (using 20 mm graded stone aggregate) for slab supported on walls beam and column in floor, roofs, landings, all as specified . 43 M&L granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing 15 mm thick screed bedcomplete all as specified 44 M&L in repair , vitreous china wash down water closet pan ( pedestal pattern) white (excluding fixing bolt , flushing cistern and flush pipe) complete all as specified and directed. 45 S&F PVC valveless,10 liters symphonic action cistern, low level, white, with inlet, ball valve, float and including brackets and connection to pipes complete all as specified and directed. 46 S&F vitreous china wash basin white, flat back size 550x400 mm including bracket, waste coupling, waste pipe complete all as specified. 47 S&F 600 x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass & screws and cup washers complete all as specified and directed. 48 S&F aluminium anodisedtubular towel rail 20 mm dia with brackets complete all as specified and directed. 49 S&F in repair toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified abd directed. 50 S&F in repair Vitreous China soap tray embedded in the wall complete all as specified and directed 51 S&F in repair shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms)all as specified and directed. 52 S&F PVC (SWR) floor trap plain with grating including jointingwith solvent cement 75 mm bore complete all as specified. 53 S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors for 75 mm bore pipe complete all as specified and directed. 54 S&F for PVC (SWR) bend with access door including jointing with solvent cement 75 mm bore complete all as specified. 55 S&F for PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors for 110 mm bore pipe complete all as specified and directed. 56 S&F for PVC (SWR) bend with access door including jointing with solvent cement 110 mm bore complete all as specified. 57 Demolition and breaking up drain pipe 75/100 mm dia (AC, salt glazed, PVC or RCC pipes ) set in cement mortar or any description including excavation of earth, returning filling, removal and making good complete all as specified. 58 M&L for PCC 1:4:8 type D1(using 40 mm grade stone aggregate) as in bed to drain pipes including packing under and haunching against the side of pipes after these are laid tested for 150 mm bore of pipes complete all as directed. 59 S&F 15mm bore Bib taps, cast copper alloy, with crutch or butterfly handle screwed down, screwed for iron or brass ferrule and fixed but fancy type complete all as specified and directed. 60 S&F in repairbrass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. 61 S&F PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed. 62 S&F 15mm dia angle stop valve of CP any colour high pressure screwed for for iron pipe and fixed complete all as specified and directed. 63 S&Fin repairs CP health faucet mild steelchromium plated suitable for 15 mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook incl makingconnection and fixed in position with angle valve complete all as specified and directed. 64 Removal of existing water tank and S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all all as specified in SSR part -I complete all as specified and directed. 65 Taking up or down 15mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed. 66 M&L for GI tubing medium grade galvanised with all fittings complete to wall, ceilings or laid on roof top all as specified and directed for 15 mm bore complete all as specified and directed. 67 S&F mild steel framed work such as grills, frame work of water tanks FE 290 Gde E-165 complete all as specified and directed. 68 S&F10 user LLDPE septic tank conventional to carry sewage and sludge water , excavation in any type of soil ,PCC 1:4:8 below foundation , vent shaft connection etc complete all as specified and directed 69 Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4m dia and 3m depth complete all as specified and directed. 70 Taking down carefully copper/aluminium point wiring (light. Fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. 71 M&Lfor point wiring for using 1.5 sqmm nominal cross section area copper conductor multistandard PVC unsheathed, FRLS cable in and including using PVC casing capping not less than 25mm size and fittings including PVC box with suitable size of pvc sheet for top cover (ISI marked) fitted with chromium plated steel screws and washer and 1.5 Sqmm nominal cross section area multistandared copper conductors FRLS green PVC insulated unsheathed earth wire and connecting to earth dolly using colour code as per IS including terminal boxes suitable for fixing socket and switches one light point/fan point/Ex fan point controlled by one 5 Amps switch one way all as specified as directed by engineer in chargeMake : Anchor/ Havells/ Finolex/ Polycab 72 All as per ser item No 71 here-in-before but one 3 pin 5 Amp switch socket outlet on same board with accessories 73 All as per ser item No 71 here-in-before but one 3 pin 5 Amp switch socket outlet on independent board 74 S&F switch piano Flush type, single pole, one way 5 amp 240 volts, complete all as specified and as directed. 75 S&FSocket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. 76 M&Lfor point wiring for using 2.5 sqmm nominal cross section area copper conductor multistandard PVC unsheathed, FRLS cable in and including using PVC casing capping not less than 25mm size and fittings including PVC box with suitable size of pvc sheet for top cover (ISI marked) fitted with chromium plated steel screws and washer and 2.5 Sqmm nominal cross section area multistandared copper conductors FRLS green PVC insulated unsheathed earth wire and connecting to earth dolly using colour code as per IS including terminal boxes suitable for fixing socket and switches complete all as specified and directed by Engineer-in-Charge. 77 S&F Switch socket combination 2 in 1, 3 pin,5 and 15 Amp flush type,universsal complete all as specified and directed. 78 S&F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with twocore flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 79 S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed. 80 S&F ceiling rose, 3 Terminal /PVC/ polycarbonate, isolated body complete all as specified. 81 S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed. 82 S&F in repairs MCB, SPN 63 Amps 240 VoltsC curve, complete all as specified and directed. 83 S&F MCB SP 6 to 32 Amps, 240 Volts, C Curve complete all as specified and directed. 84 S&F LED inverter Bulb 12 Watt. 85 S&F ledluminaire comprising of high brightness LEDs 9/10W LED, IP-65/66 complete all as specified and as directed.Make : Havells or equivalent in Bajaj/PHILIPS/CG 86 S&F MCB, DB,TPN, double door, IP-43, 8 waywith 200 A rated bus bar having earth terminal, including MCCB 250 Amps as incomer and and mcb sp as out going for DB SPN complete in all respect Concealed in wall including making electrical incoming and outgoing connection with legs/thimbles all as specified and directed. Make : Siemens/ Legrand/ABB/Havells/C&S 87 M&L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm diaPVC conduit/casing capping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed.Note: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of casing capping shall be measured as one RM Make : Anchor/ Havells/ Finolex/ Polycab 88 M&L in repairs for Earthing complete with galvanizedsteel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work as Excavation, RF and removal etc. 89 S&F exhaust fancomplete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200/250/300mm 90 S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd 91 S&F 35 W LED new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver suitable for fixing on building complete all as specified and directed. 92 S&F building security lights LED 30 W 93 Supply ,Laying ,connecting/ Jointing, charging, testing and commissioning LT cable electric, XLPE insulated, armoured, PVC sheathed, heavy duty, electric cable 1100 Volt grade withstranded aluminiumconductor conforming to IS :7098, laid in trenches/ducts/fixed to wall /roofs/ poles all as specified of size3.5 Core 50 sq mm . including taking outold unserviceable cable from any space complete all as specified and directed. 94 Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holesetc not exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out of soft/lose soil for taking out pipe & laying of pipe & getting outfor diverting of CI pipeline complete all as specified and directed. 95 Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. 96 Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm complete all as specified and directed. 97 M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified 98 M&L for Sub class B bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified. 99 S&F GI Tubing light grade 40mm dia with all fitting; laid in trenches all as specified and directed
Contract Date: Jan 24, 2026 Contract Value : 67.81 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Jammu And Kashmir View Result →
22.
Defence #8627665 AOC
Tender For Provision Of Water Supply Scheme Alongwith Allied Infra At Rajouri Under Ge 862 Ews; 1 Schedule A Part-I (Building Work) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 siginifies this fact only. 2 Construction of Pump House building complete all as specified and shown on drawing. 3 Construction of RCC UG Sumpof capacity 40,000.00 Gallon complete all as specified and shown on drawing. 4 Schedule A Part-II (Internal electrification works) 5 Total amount of Sch A Part-II (Internal electrification works) brought forward from srl page No-22 6 Schedule A Part-III (Internal water supply works) 7 Total amount of Sch A Part-III (Internal water supply works) brought forward from srl page No-26 8 Schedule A Part-IV(DG Set Works) 9 Total amount of Sch A Part-IV (DG Set Works) brought forward from srl page No-25 10 Schedule A Part-V(Sewage Disposal Works) 11 Total amount of Sch A Part-V (Sewage Disposal Works) brought forward from srl page No-27 12 Schedule A Part-VI (External electrification Works) 13 Total amount of Sch A Part-VI (External electrification Works) brought forward from srl page No-31 14 Schedule A Part-VII (External water supply Works) 15 Total amount of Sch A Part-VII (External water supply Works) brought forward from srl page No-33 16 Schedule APart-VIII (Misc Items of Works) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 siginifies this fact only. 17 Construction of conventional type on site LLDPE septic tank designed to carry sewage and sludge water for 05 users with & including earthwork in any type of soil, PCC 1:4:8 below foundation, vent shaft & making connection, complete all as specified and directed. 18 Costruction of soakage well 2.40 mtr dia and 3.00 mtr depp below inlet (depth) from inlet pipe to ground level 45cm including excavation and earth work in any type of soil, PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate in foundation, wall in honey combed brick work in CM 1:4 cover slab of M-25 filling with brick bats, earth cushion on brick lining on top and inlet pipe 150mm dia and complete all as specified and shown on drawing 19 Supply Insttalation and testing of30 HP centrifugal, Pump set heavy duty with fully automatic star delta starterelectric driven,415 volt 3 phase 50 Hz. discharge capacity of pump set should be440 LPM at 135 Mtr head.completerequired with all necessary fitting and copper cablesingle core 70 sqmm for connection from LT panel to Starteras per suitable length in three phase supply including panel board of suitable size for fixing the starter and PCC foundation with chasis complete with nut bolt and channal all as directed at side(01+01 nos stand by) complete all as specified and as directed by Engineer-in-Charge. 20 Supply and fixing of CI Foot valve unit, suitable for 100mmbore conforming to IS-4038 including nuts ,bolts and washersetcfixing the same to the suction pipe for suitable depth in the UG sump ofthe pump set complete all as specified and directed. 21 M&L for valve chamber and construction of brick masonarry new valve pit chamber of size 1200mmx1200mmx1200mm (internal ) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6rendering in cement 1:6 finished even smooth using extra cement internally and 20mmthickin CM 1:4and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle ironframe embbeded in PCC copingwith locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplyingtwo coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed. 22 supply and fixing Air release Valve Cast Ironwith two air Outlets, 100 mm dia bore and fixing Up in cast iron water supply mains, complete all as specified and as directed. 23 Supply fabrication and and erection structuarl steel workmade out of angle iron channels flats etc by riveted bolted or welded in built up section trusses in and including cutting hoisting fixing in position and applying two coat of wether proof synthetic enamel paint over a primera coat of anti-corrosive primer of approved colour suitable for base platform of 50000 ltr Smc watertank complete all as specified and as directed . 24 Supply & fixing of sintex SMC panel tank capacity 50000Ltrsquare type, made out of HOT PRESSMOULDED SHEET MOULDING COMPOUND panelsof size 1005mm x 1005mm x 75mm (flange), 1005mm x 2010mm x 75mm (flange) and 1005mm x 502mm x (flange) the flange should be perpendicular to the main surface. The shape shouldbe Trunked type for extra strength and 90 degree flanges pre drilled for bolting. All the Flanges of the 1 mt Panel should have 13 Nos. holes per sidefor fastening/joining the panels to one another. Hot Pressed Moulded SMC Pre Drilled Corner Pieces with built-in ribs of the size 75mm x 75mm should be provided for 90 degree joints of tanks wall to roof jointscomplete with olive green nuts, bolts and washers. Special sealent having excellentUV Resistance as well as suitable for portable water, complete with top covered construction having man hole with cover dia 600mm and internal FRP Ladder.The SMC Panelmust be ISI marked meeteing BIS 14399(part 1 & 2).Tank inlet and outlet size 80mm dia for connection of GI pipe all as specified and directed.(Make - Sintex or equivalent make as approved by GE) including cross arms works panel hight from grond level to 20feet all as directed at site. Note-:Structural work like cross arms, bracings etc shall bemeasured and paid separetlly . 25 Supply, installation, commissioning and testing ofservo controlled Voltage Stabiliser fully automatic operation, unbalanced type (individual phase control), copper wound 415 V, 50 Hz confirming to BIS 9815 : Part 1 : 1994 reaffirmed 2009, IP-45, three phase naturally oil cooled, indoor type & designed for input variation between 300 volts to 480 volts with output voltage stabilised at 415 volt with accuracy ±1.0% and speed of correction 15 volts per second of capacity 100 KVA including first filling of transformer oil having dielectric strength not less than 150 KV as per IS:335, 0-500 volts voltmeter, arrangment to check input voltage and output voltage, RYB indication lamp, high & low voltage cut off system, single phase preventor, time delay relay, servo byepass switch, overload & short circuit trip system, ammeter, oil level gauge& capacity overload 20% overload for one hour etc.,completeall as specified & directed 26 Supply,install,testing and commissioning outdoor type step down transformer 11000 volts/433 volts (at no load) ,AC , 3 phase 50Hz capacity 100 KVA corec type double copper wound , oil immersed , naturally cooled, oil natural, air natural (ONAN) with external cooling fins , delta connected on primary side (HV) ) star connected on secondary side (LV) in accordance with vector symbol , Dyn 11 (vector group) with neutral brought out on secondary side (LV side) and having tapping at +5% to -10% (at 2.5% each step) HV side to be changed by means of hand operated off load tap changer gear. The Transformer shall be IS 1180Part 1:2014 (level -2) and BEE certied and shall comprise of the following :- (a) cable end box on HT side suitable for 95sqmm 3 core XLPE cable (b) cable end box on LV side suitable for 150sqmm 3.5 core XLPE cable (c)Oil conservator with filter type frain valve and oil level gauge (d)dehyderating breather with first fill dehyderating agent (silica gel)(e) explosive vent(f)Thermometer pocket on tank cover(h) Two earthing terminals on tank cover to facilate fixing of 32x6mm copper earth strip for earthing of neutral body. 27 (g)one no 100mm dia , dial type thermometer , vapour pressure type , having range 0-120 degree celcius with metal guard having maximim perimeter reading , temperature indicator with resisting device for transformer. (i)Rating plate and terminal making plate (j)oil level gauge (k)oil drain/filter valve(l) lifting lugs (m) Oil filling hole with cap / plug with connecting plate complete (n) air release valve plug(o)Four plain solid cast steel deattachable rollers(p)extra bushing for neutral , outside the LT cable box for providing independent earthing for Neutral(q)First filling of new and unused transformer oil IS:35/93(4th revision), marked (Make:Savita/Poweroil) filtered and tested upto 40KV dielectric strength at 2.5mm air gap between testing. 28 Supply , installation, testing and commissioning ofLT Panel outdoor typefabicrated of 3.15mm thick CRCA sheet dust and vermin proof powder coated double door type independent cabin including locking arrangement for each MCCBs, bus bar rated 400 Ampenclosed complete suitable for operating on 415 volt 50 Hz AC supply internally wired with copper conductor/strip of adequate size from main incoming MCCB to bus bar and bus bar to outgoing MCCB/MCBs having legs 45cm made out of 65x65x6mm angle iron grouted on brick masonary platfor upto 30 Cm. Brick masonary platform should be 60Cm above the ground level, comprising the following:- (a) 4 Pole MCCB 25 KA 250 A - 1 Nos(b) Digital Ammeter with CTs& selector switch - 1 Nos(c) Digital Voltmeter & selector switch - 1 Nos(d) 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA -03 Nos(e) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA - 01 Nos(f) SPN MCB 40A- 01 Nos.(g) Onload changeover TPN 250 A - 01 No. (h)copper bus bar TPN 250 Amps rating -01 set 29 Angle Lamp holder insulated body with back plate for batten fittings and including one15 Watt LED Bulb non dimmable B-22 cool daylight all as specified and as directed. 30 Supply and fixingEnvironmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm, complete all as specified and as directed. 31 Supplying, installing, testing & commissioning of factory assembled Diesel Engine withdriven generating set coupled withalternator AC to give continuous output of 100KVA at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, directly coupled with diesel engine, watercooled, mounted on common base frame complete with in built fuel tank (service tank) of adequatecapacity with fuel line, built in electronic governor & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads,control panelshowing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the under-mentioned technical specifications confirming to BS:5514 & IS 10000 complete in all respect with following accessories, parts all as specified & directed.(a) DIESEL ENGINE :4 cylinders , turbo charged watercooledat 1500 RPM under NTP conditionsIS 4722, BS 5000, IEC 3411, ISO 8528, BS 5514, ISO 3046, conforming to with an overload capacity of 10% for one hour in 12 hrsof continuousoperationwith the following accessories 32 (i) Radiator with blower fan or heat exchanger with guard .(ii) Pipe coupling for engine cooling system piping (iii) Corrosion inhibitor coolant(iv) Paper element filters-(i)Fuel(ii) Lube oil(iii) By Pass(vi) Fly wheel housing and fly wheel to suit (vii) Engine bearing mechanism in fly wheel housing (viii) shut off coil with safety for LLOP /HWT./ Over speed.(ix) Dry type air cleaners and vacuum indicators .(x)Residentialsilencers.(xi)Stainless steel exhaust flexible bellows.(xii)Motor driven priming pump.(xiii) Electric starter.(xiv)Battery charging alternator.(xv) Exhaust piping made outof STICC class MS Pipe inclusive of all accessories and hardware , necessary supportas per manufacturer’s recommendations to sustain back pressure with rain cap(xvi) Mineral wool insulation 2 inch thick covered with aluminium sheets of 30 gauges for the entire length of exhaust pipe.(xvii) First fill of oil coolant and diesel during commission and 12 hours testing.(xviii)Interconnecting copper cabling of adequate capacity between batteries andcontroller.(xix) Fuel pipe. Fuel Tank_ 24 hours full load diesel storage capacity inbuilt fuel tank with mounting brackets factory fabricated made of MS sheet with level indicator fuel inlet , fuel outlet , air vent, drain plug,inlet arrangement filling from exterior of canopy etc. 33 (xx) Battery :- 150 AH,12 Volts maintenance free battery of Qty-2 Nos with leads and terminal. (xxi) PCC Foundation :- Civil work and PCC foundation for installation DG Set as per manufacturers instruction.(b) ALTRERNATOR : 100 KVA at 0.8 PF lagging, 415 volts, 3 Phase, 4 wire, 50 Hz at 1500 RPM self excited and self regulated with AVR brushless excitation band of voltage ± 1% of rated voltage from no load to full load insulation class H, IP-23 self ventilated and conforming to IS4722, BS5000, IEC 34/1, ISO 8528, BS5514, ISO3046, suitable for above mentioned diesel engine complete all as specified and directed . (c) ACOUSTIC ENCLOSURE : Factory made acoustic enclosure (canopy) 100 KVA DG set to reduce noise level to 75 db (A), measuredat 1.00, meter distance @75% load auditable frequencies as per guidelines of CPCB & comprising of following-:(i) Sound proof insulation 100mmthick Rock wool (Density 65 Kg/cum) (ii) Outer body: Not less than 1.6 mm thick CRCA. (iii) Door 1.6 mm thick CRCA(iv) Inner surface: 1.0 mm thick powder coated & perforated CRCA / GI sheet (v)Common base frame: ISMC 250 34 (d)AMF CONTROL PANEL :LT panelmadeout of 2mm thick CRCAsheets in suitable compartmentsfront openable duly powder coated for a weather proof and long lasting finishing including the following:- (i) MCCB suitaibly rated ,qty OEM recommended(Make: Legrand/Havells/L&T).(ii) contactor of suvitable size of 2 Nos. Set of phase indicating lamps with HRC fuses - 01 Set.(iii)Voltmeter 96 sq.mmdigital type 0 to500 volts rangewith selector switch: 01 set(iv) Amp meter 96 sq.mmdigital type 0 to 400 Amps range with suitable CTs complete - 01 set.(v) KWH meter digital type (vi)Digital PF meter (vii) Set of suitable CT”s(viii) Indicating lamps for supply and load on (ix)Instrument fuses (HRC type)(x) Bottom gland plates for incoming and outing cable(xi)Circuit diagram plateNOTEl: Testingh of DG Set must be done on ground by the contractor as per ground execution requirment and providing the fuel and heat load is tested by the machine for minimum of 24 Hrs. 35 Cleaning of site by way of bush cutting for operating theSuitable truck Mounted DTH drilling rigs along with accessories etc to the site of work & erecting of rig including leveling for required area for starting the job workall as specified & directed 36 Provision of trial bore hole /well of size less than 250 mm dia size pilot bore through any kind of soil/strata including hard dense stone /boulder by means of direct rotary method below ground level upto 150meter depth complete all as specified and directed by Engineer in charge.Note :- 1. The depth of trial boring of the tube well at the site indicated by the Eng-in-charge is anticipated to be 120 meter below ground level. 2. The depth may, however be ordered in writing to be varied by the Eng-in-charge up to a maximum of 25 %/150 mtr of the above mentioned depth (plus or minus). 3. If the Eng-in-charge decided that suitable water bearing strata is not available in the aforesaid bore or the boring cannot be continued further on account of the type of strata ,4c Further Eng-in-charge may order the contractor to bore at other site(s) 5. Eng-in-charge shall give three no. of directionto the contractor for trial hole/well of size less than 250mm dia.6. No any extra charge to be provided to contractor 37 M & L for reaming of developmentbore by reaming of 250mmfor 60 RM from ground level complete all as specified and directed. 38 M & L for Reaming of development bore from depth exceeding 60 metre to 120 meter of dia 250 mmcomplete all as specified and directed. 39 Supply ,assembling including jointing lowering and fixing MS ERW blind pipe200 mm dia and thickness 8mm including all fittings and fixtures upto 100m deep complete all as specified & directed. 40 Supply ,assembling including jointing lowering and fixing slotted MS ERW pipe 200 mm dia and thickness 8mm including all fittings and fixtures complete all as specified & directed. 41 M&L for strata sample (at every 6 meters depth) one set in suitable box pattern, earth sample strata should be produced as per IS and submitted to the department. The box shall be 2nd class hard wood with suitable locking arrangement etc complete all as specified and directed. 42 M&L for borewell chart on acrylic sheet of size 60 cm x 15 cm duly marked permanent marking including 12mm thick plywood frame, clamps for fixing on wall etc all as specified and directed. 43 M&L for development of tubewell by means of over puming high velocity jetting with 600 PSI Air compressor all as specified in IS 8110-2000 PARA 4.3 including arrangement for equipment fitting and supplyl of sodium hepta sulphate 60 kg complete all as specified & directed. 44 All asper Sl item no 8.23 above but by means of over pumping muddy water for subsequent hours until clear discharge as per clause 9.3 of IS 2800(Part-1)-2009 complete all as specified and directed. 45 Collection of sample of water and conduct testing in Govt lab for all parameters (Chemical and Bacteriological Tests) of water to assess the potability and submit the report complete all as spcified and directed. 46 Supply & Fixing of MS well cap for 200mm dia of thickness 8 mm of pipe at the top of casing pipe of bore well with locking arrangement complete all as specified and directed. 47 Supply & packing of pea gravel 20mm to 25mm size of approaved quality as ordered to packed around the casing pipe/slotted pipe in the bore well to entire depth complete all as specified & directed 48 Supply & Fixing MS flat Iron clamp 100mm x 10mm thicksize clamp fixed with 16mm dia nut bolts and washers 2 on both sides of clampfor holding 65mm MS column pipe,2Noscomplete all as specified and directed. 49 Supply, installation, commissioning and testing of submersible pump setof capacity 15 HP ,electric driven, 415 volts discharge430 LPMat 135 mtr headwith CI Impeller, CI diffuser, EN-8 shaft, stainless steel stainer comprising with suitable capacity of Electric motor designed for working on 415 volts, 3 Phase, 50Hz, filled with oil for effective cooling and life long lubrication of heavy duty ball bearing and mechanical seal complete with Digital electronic softstardelta starter of suitable capacity includidfitted on suitable size panel board included with & including protections against over load, single phase, phase seque nce reversalcomplete all as specifed and as directed. Note: the capacity od Submersible pump may be change as per depth of borewell for required yield of water. No extra payment shall be made to contractor. Note:- 1. Rate quoted by contractor deemed to be inclusive for the cost for calculating the capacity of submersible pump set . In this regard a certificate along with the copy of the design of the pump by manufactrer shall be furnished by the contractor for suitability of the motor for selected pump suitable for bore as to deliver continuous water with stable LPM. 2. Rates quoted by contractor deemed to be inclusive of one set of submersible pump and conected items are installed in borewell and one set of submersible pump and connected items as stand by. 50 M&L for provision of MS Tie rod for anchoring of submersible pump set fabricating out ofIron rod of size 8 to 10 mm, 2 Nos. vertical to hold the submersible pump set alongwith column pipes, length suitable to length of submersible pump set including suitable nut bolts and washers including tail piece of size 65mm of 1mtr length having one side flaged end and other end threaded for fixing with submersible pump including two Nos suitable size welded Flat Iron 40mmx6mm size with holes for fixing of tie rod complete all as directed. 51 Supply and fix PVC insulated and PVC sheathed multi stranded copper conductor cable for submersible pump set, ISI marked, conforming to IS-864 of size 3 core 10 Sqmm, 1100 volts grade, including necessary water proof connection to submersible pump at cable lead complete all as specified and directed. 52 Supply & Fixing pipe GI tubing heavy grade 80 mm bore duly welded flanged (thickness of flange 12mm having 04 holes) with and including rubber packing of 6mm thick, nuts, bolts, washers complete in 3 mtr length as column pipe in bore well complete all as specified and directed. 53 Supply and lowering stainless steel V wire screen 150mm dia, K type packet(wall thickness should not be less than 8mm), with opening 0.50mm, inside the tube well assembly in the manner with top of the packet resting on the lowermost end of the assembly complete all as specifed & directed.Note:-1. The Screen pipe shall be lowered as per requirement of the borewell at desired depth inside the MS casing pipe.2. Screen pipe shall be lowered as to hang with the end of MS casing pipe lowered. 54 Supply & fixing suitable casing drive shoe for 200mm dia and bit tube as per requirement of depth or ODEX attachment all as specifed & directed by Engr -in-charge.
Contract Date: Jan 19, 2026 Contract Value : 1.29 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
Jammu And Kashmir View Result →
23.
Defence #8544983 AOC
Tender For Addition Alteration To Bldg No Sm-11 At Patiala Under Ge South Patiala; 1 Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and as directed. 2 Demolition of mud phuska on roof any thickness including plastering and leeping plaster( whether full thickness removed or part thereof) complete all as specified and as directed. 3 Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed. 4 Material and labour for cement concrete 1:3:6, type B-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 25mm to maintain a slope of 1:100complete all as specified and as directed. 5 Material and labour for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed. 6 Material and labour for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) and applying bitumen 85/25 grade @ 0.1.20kg/sqm over and including 0.30 kg/sqm bitumen primer and landed APP membrane on surface by Torch application complete all as specified and as directed. 7 Material and labour for roof Tiles with SRI>90 premium quality tiles of approved shade 300 X 300 mm and 10 mm thick, at roof tops/ terraces etc. in any pattern of light & dark tiles as approved, laid over & including 20 mm thick screed in cement mortar (1:4) over and jointed & pointed in matching coloured cement based tile joint filler (Roff -Pidilite or equivalent as approved) complete all as specified and as directed.Make : Johnson (Cool Roof Tiles) / Orient (Cool Roof Tiles) 8 Material and labour for cement concrete1:2:4, type B-0 (using 12.5mm graded stone aggregates) as in roof kerbs, benching, mud stops, steps, coping, hold fasts and the like slightly rounded or chamfered on the edges complete all as specified and as directed. 9 Taking down eaves, gutters and rain water pipes (any sizes or pattern) including all fittings head, shoes, bend, swan neck etc and cleaning for refixing or removing to store complete all as specified and as directed. 10 Supply and fixing UPVC (SWR) Type ‘B’ , 160 mm nominal outside diameter confirming to IS : 13592-1992 single socketed in any length including jointing with lubricant/ PVC cement solvent as per manufacturer’s instruction”, fixed to walls with MS flat iron clamps of size 25 x 3mm, bolts, washers, nuts, nails etc, complete all as specified and as directed. Note: MS flat iron clamps will be measured and paid separately in respective item.Makes : Supreme/ Finolex/ Astral 11 Supply and fixing UPVC (SWR) bends, 160 mm dia confirming to IS : 14735-99 and jointing with lubricant/ PVC cement solvent as per manufacturer’s instruction”, complete all as specified and as directed.Makes : Supreme/ Finolex/ Astral 12 Supply and fixingMS Clamps, Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay) and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed 13 Demolition of reinforced cement concrete as in Roof slabs, floors slabs (other than ground floors), beams, roof beams, roof projections, chajjas, staircases, landing, chajjas, fins and similar suspended work( reinforcement cut as required to facilitate demolition) complete all as specified and as directed. 14 Material and labour forreinforced cement concreteM-25 (Design Mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, chajjas, fins, roof projections, staircase, steps, parapets and shelves and the like items all as specified and as directed 15 Material and labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 16 All as per serial item no.15 here-in-before but5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and as directed 17 Material and labour for form work of flat surface rough finished surface of concrete to soffits of suspended slabs such as roof slabs, shelves not exc 200mm thick upto 10m height (Horizontal or sloping) complete all as specified and as directed. 18 Material and labour for form workto edges of concrete slabs exc 10 cm but not exc 20 cm thick forrough finished surface of concrete complete all as specified and as directed 19 Material and labour for form workto edges of concrete slabs exc 5 cm but not exc 20 cm thick 1forrough finished surface of concrete complete all as specified and as directed 20 Material and labour for form work work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc,flat surface vertical or to batter for rough finished surface of concrete complete all as specified and as directed 21 Material and labour for form work work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.flat surfacefor rough finished surface of concrete complete all as specified and as directed 22 Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified and as directed. 23 Material and labour for brick work with Fly ash bricks minimum class designation 100 straight or curved on plan exceeding 6m mean raidus bulit in cement mortar 1:6 complete all as specified and as directed 24 Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits/ceilings etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and as directed. 25 Material and labour for rendering 15mm thick on fair faces of brick or concrete surface in cement mortar 1:4, mixed with liquid water proofing compoundas per manufacturers instructions, finishing surface even and fair w/o using extra Cement, complete all asspecified and as directed.Note: Liquid WPC will be measured and paid separately under respective item of this schedule. 26 Supply only integral liquid water proofing compound complete all as specified and directed. 27 Material and labour for rendering 10 mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. 28 Material and labour for rendering 5 mm thick on fair faces of concrete surface as in ceiling in cement mortar 1:3 finished even & smooth without using extra cement complete all as specified and as directed. 29 Material and labour for complete removal of existing treatment on wall / roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding paper of appropriate grit to make suraface clean , free from dust, loose paint etc by skilled labour complete all as specified and as directed. Note: Sanding of suraface shall be done by mechanical sander with 1500-2700rpm, with internal dust extraction system for clean environment certified by paint manfacturer.Proper masking to be carried out before primer and paint application. 30 Material and labour for prepration of plastered surfaceof walls (external/internal surfaces) /ceilings / soffits etc and applyingwall care putty (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) using ready made wall care putty including sandingthe suface with suitable sand paper to achieve smooth surface for receiving painting etc complete all as specified and as directed.Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. 31 Material and labour for prepration of puttied surfaceof walls (external surfaces) /ceilings / soffits etc and applyingapplying 02 coats of exterior emulsion paint (light shade) with highlighter of any approved shade,@ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer using fully automatic airless spray machine having flow speed of min. 1 lit/minute and pressure of 3300psicomplete all as specified and as directed.Make of Exterior Wall Primer: Asian / Berger / Nerolac [Best Quality].Make of Exterior Emulsion: Asian (Apex) / Berger (WEATHER COAT) / Nerolac (Excel) . 32 Material and labour for prepration of puttied surfaceof walls (internal surfaces) /ceilings / soffits etc applying 02 coats of interior emulsion paint (light shade) @ 10 sq.m/litre/2 coats by using roller/brush to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturerusing fully automatic airless spray machine having flow speed of minimum 1 ltr/minute and pressure of 3300PSI complete all as specified and directed.Make of Interior Wall Primer: Asian / Berger / Nerolac [Best Quality].Make of Interior Emulsion : Asian (Tractor Shyne)/ Berger (BISON Glow) / Nerolac (BEAUTY SHEEN) 33 Material and labour for prepration of puttied surfaceof walls (external/internal surfaces) /ceilings / soffits etc applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceilings surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturerusing fully automatic airless spray machine having flow speed of min. 1 ltr/minute and pressure of 3300PSI complete all as specified and directed.Notes: For serial. item No. 29 to 33.Work for periodical services shall include the following and the rates quoted by the bidders shall include the same:-(a) The work pretening to periodical services shall be executed by the contractor as per MOU from authorised applicator through manufacturer of the materials like Exterior emulsion paint , putty etc after approval of the GE.(b) The contactor shell upload with the documents under cover I Memorandumof understanding (MOU) as per formate given in annexure A after schedule A notes with atleast one of the manufacturers mentioned in the Contracts, failing which the bid shell be liable to be rejected. (c) Use of scaffolding, trestle, ladders, cradles etc necessary for execution of work, protective measures.(d) The removing of nails, making good holes, cracks etc.(e) Work in patches and in narrow/ width, bends, cornices , plasters etc and cutting in edge of line where necessary and issurance to theworker.(f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes.(g) Washing floors, cleaning glass , joinery , electric fittings , wirings etc drops and splashes of paint to be cleaned to the entire satisfaction of Engr-in-charge. (h) The items shell be got executed through authorised applicator of manufacturers that is Asian paint limited/Kansai Nerolac paint limited /Berger paint India limited or any other reputed manufacturer as approved by GE.Make of Interior Wall Primer: Asian / Berger / Nerolac [Best Quality].Make of Interior Emulsion : Asian (Tractor Shyne)/ Berger (BISON Glow) / Nerolac (BEAUTY SHEEN) 34 Dismantling, floor, hearth or wall tiling including cement motrar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and as directed 35 Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified and as directed. 36 Demolition of cement concrete ( unreinforced ) in ground floors and pavings n.exc 15cm thicknesscomplete all as specified and as directed. 37 Material and labour for cement cocnrete 1:2:4, type B-0(using12.5mm graded stone aggregate) as in sub-base,flooring,paving etc complete all as specified and as directed. 38 Material and labour for 100mm thick cement concrete 1:4:8type D-2 (using 40 mm graded stone aggregates) as in sub-bases, floos, paving etc complete all as specified and as directed. 39 Material and labour for ceramic glossy finish, joint free premium quality coloured tiles 600 X 300 mm and 7-9 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry laid over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and as directed.Note : Dado/skirting should be flushed with the wall plastering. 40 Material and labour for Polished Glazed Vitrified Tiles (PGVT) joint free premium quality coloured tiles 600 X 1200 mm and 8-10 mm thick, as in skirting/dado etc. laid with 3-5mm spacers and grooves shall be filled with epoxy grout (Pidilite or equivalent) of approved matching colour. in any pattern of light & dark tiles as approved, laid and jointed in suitable adhesive (flexiset H-40 or equivalent as approved) as per manufacturers instructions and pointed in matching coloured cement based tile joint filler (Roff -Pidilite or equivalent as approved), in floors etc. laid over & including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed.Note :The rates for labour and material for spacers/ grovers shall be deemed to be included in the quoted unit rates and nothing shall not be measured & paid separately on this account. 41 Material and labour for mat finish anti skid vitrified tile joint free premium quality coloured tiles 600 X 600 mm and 8-10 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc.laid over & including 20 mm thick screed in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed. 42 Material and labour for mat finish anti skid ceramic tile joint free premium quality coloured tiles 300 X 300 mm and 6-8 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc. over & including 20 mm thick screed in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified. 43 Material and labour for full Body Vitrifiedjoint free premium quality coloured tiles 600 X 600 mm and 8-10 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc. laid over & including 20 mm thick screed in cement mortar (1:4)and pointed in white cement mixed with pigment to match the colour of tiles complete all as specified and as directed. 44 Material and labour for Polished Glazed Vitrified Tiles (PGVT) joint free premium quality coloured tiles, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm and 8-10 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, laid and jointed in suitable adhesive (flexiset H-40 or equivalent as approved) as per manufacturers instructions and pointed in matching coloured cement based tile joint filler (Roff -Pidilite or equivalent as approved), in floors etc.laidover & including 20 mm thick screed in cement mortar (1:4) over complete all as specified and as directed. 45 Material and labour for Polished Glazed Vitrified Tiles (PGVT) joint free premium quality coloured tiles, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm and 8-10 mm thick, as in skirting/dado etc. in any pattern of light & dark tiles as approved, laid and jointed in suitable adhesive (flexiset H-40 or equivalent as approved) as per manufacturers instructions and pointed in matching coloured cement based tile joint filler (Roff -Pidilite or equivalent as approved), in floors etc.laid over & including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed. 46 Material and labour for Polished Glazed Vitrified Tiles (PGVT) joint free premium quality coloured tiles 800 X 1600 mm and 8-10 mm thick, as in floors etc. in any pattern of light & dark tiles as approved, laid and jointed in suitable adhesive (flexiset H-40 or equivalent as approved) as per manufacturers instructions and pointed in matching coloured cement based tile joint filler (Roff -Pidilite or equivalent as approved), in floors etc. laid over & including 20 mm thick screed in cement mortar (1:4) complete all as specified and as directed. 47 Material and labour for Polished Glazed Vitrified Tiles (PGVT) joint free premium quality coloured tiles 800 X 1600 mm and 8-10 mm thick, as in skirting/dado etc. in any pattern of light & dark tiles as approved, laid and jointed in suitable adhesive (flexiset H-40 or equivalent as approved) as per manufacturers instructions and pointed in matching coloured cement based tile joint filler (Roff -Pidilite or equivalent as approved), in floors etc.laid over & including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed. 48 Material and labour for Machine cut kota stone slab (nearest to 58cmx58cm in size) as in flooring 20-25mm thick laid over and including 20-22 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 100mm wide border of Baroda Green Marble complete all as specified andas directed. 49 Material and labour for pre-polished Baroda Green marble, machine cut as in floorings/ shelves/ steps/ cills/ jambs/ skirting/ border only in tile flooring and the like works and flooring etc, 15-16 mm thick including bull-nose the exposed sides/lengths, set and jointed in cement slurry laid over & including screedof 15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab for fixing on concrete surfaces or with suitable adhesive for fixing including 100mm wide border of White Marble in flooring complete all as specified and asdirected. Note : Single piece shall be used in steps/cills/jambs/shelves. 50 Materaial and labourfor nano tiles 15mm thick of size 800x2400 mm of any shade as approved machine cut as in flooring shelves/steps/counter tops, set and jointed in cement slurry laid over & including15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive and including bull nose on exposed sides complete all as specified and as directed . Note : Single piece should be used in steps/cills/jambs/shelves. 51 Material and labour for Granite (Jet Black colour/shade-South Indian) of any type machine cut as in flooring, shelves/steps/counter tops, 18-20 mm thick, set and jointed in cement slurry laid over & including screedof 15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive for fixing and bull nose on exposed sides/lengths complete all as specified . Note : Single piece should be used in steps/cills/jambs/shelves. 52 Material and labour for cement concrete (1:2:4) type B-1( using 20 mm graded stone aggregates), 50 mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints and filling the same with polyureathene complete all as specified and as directed. 53 Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqmincluding cutting holes for inserting hold fast for new frame depthexceeding half but n,exc one brickand making good to disturbed surfaces complete all as specified and as directed. 54 Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm iincluding cutting holes for inserting hold fast for new frame depthexceeding half but n,exc one brickand making good to disturbed surfaces complete all as specified and as directed. 55 Supply and fixing factory made single extruded “Pre-laminated WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat with corner round with back grooves of size 100X62-65 mm”comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note:(i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately. Make : Alstone / Century / Rajshree 56 supply and fixing factory made single extruded “Pre-laminated WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat with corner round with back grooves of size 150X62-65 mm” comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately. Make : Alstone / Century / Rajshree 57 Material and labour for cement concrete (1:2:4) using 12.50 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats, hold fasts etc. complete all as specified and as directed. 58 “Supply and fixing factory made flush shutters 30mm thick minimum 5 ply and laminated on both faces with laminate of approved shade, solid core construction, with block board core and plywood face panels, commercial type on both sides with 6mm thick lipping frame to match and PVC tape to matching the shade of laminate on the edges complete all as specified and as directed.” 59 Supply and fixing 35mm thick glazed and skelton shutters of 2nd class hard wood for doors (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Part I, Section 8, clause 8.24 (a);, kiln seasoned and chemically pressure treated complete all as specified and as directed. Note : Glass panes, wire cloth, etc.shall be measured and paid separately. 60 Material and labour for preparation of new wooden of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of pinl primer complete all as specified and as directed. 61 Material and labour for preparation of new or previously untreated surfaces of steel and iron work of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and as directed. 62 Supply and fixing powder coated Anodised aluminium frame ( minimum thickness of powder coating 50 mm) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. 63 Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket, etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and as directed.Note: Glass and other filling material in panels shall be measured and paid for separately under respective items. 64 Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) rfor shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws complete all as specified and as directed. 65 Supply and fixing powder coated (minimum thickness of powder coating 50 micron) anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete all as specified and as directed,. 66 Supplying and fixing of Unplasticised Poly Vinyl Chloride (UPVC) 3 track sliding Window with mesh shutter – (2-glass shutter and 1-mesh shutter) duly manufactured using UPVC reinforced profiles (Composition of profile shall consists a minimum of 5.5 PHR of TiO2 and not more than 12 PHR of CaCo3 for every 100 parts of PVC resin) of (112 mm x 52 mm) x 2.20 mm for outer frames, (41 mm x 61 mm) x 2.20mm for sliding shutter frames capable of mounting single glazing system structurally reinforced with hot dip galvanized up to 50 microns of minimum thickness of 1.0/1.2 mm prefabricated & welded through fusion welding. The window sash shall be fitted with 5 mm thick clear float glass of reputed make and mesh shutter frame shall be (42 mm x 61 mm) x 2.0 mm fitted with Vinyl Coated Fiber mesh- on rollers/ pulley duly fixed with Grey colour TPV Gasket for sash & Glazing bead shall be co-extruded with Grey colour soft PVC. Window shall be provided with standard hardware & Single point locking system of touch Lock system. the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site etccomplete all as specified and as directed. Make : Fenesta/NCL Zylos 67 Supply and fixing 5 mm thick clear toughened glass for glazing works etc fixed with aluminium beads/uPVC windows any size of pane complete all as specified and as directed 68 Supply and fixing 5mm thick frosted glass in ventilators/ windows/ doors fixed in any metal frame work/ aluminium / uPVC joinery all as specified and as directed. 69 Supply and fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. 70 Supply and fixing 10mm toughned/tempered frosted glass as in showers/ hinged doors, partitions, automatic doors and similar work including cutting to shape, drilling holes required of any size fixed in position with suitable stainless steel 304 Grade all types patch fittings / brackets / catchers/L-connectors/all types hinges (wall to glass/glass to glass)/magnetic seals all as specified and as directed.Make : Saint Gobain/ Modiguard Note : Hardware will be paid separately under respective items. 71 Supply and fixing 12mm toughned/tempered frosted glass as in hinged doors, partitions, automatic doors, staircase railings, roof dome works and similar work including cutting to shape, drilling holes required of any size fixed in position with suitable stainless steel 304 Grade all types patch fittings/brackets/catchers/L-connectors/all types hinges (wall to glass/glass to glass)/magnetic seals and including temorary wooden/ply frame wk required to take exact sizes as in staircase railings/ dome work of any shape etc and filling the gaps with silicon all as specified and as directed. Make : Saint Gobain/ ModiguardNote : Stainless steel Hardware will be paid separately under respective items. 72 Supply and fixing double cylinder cam action floor spring with closing force EN4 suitable for max door weight 150 Kg, max door width 1100mm with closing speed 130-10º, final closing speed 10-0º, hold open - 90º, approx weight of floor spring 6Kg, with installation dimensions of size 306x108x40mm fixed in position as per instructions of manufacture includingtop fittings/ hardware from same manufacturer complete all as specified and as directed.Make : Ozone/ Saint Gobain as approved 73 Supply and fixing H type pull glass door Handles of size 25x300/450 mm stainless steel 304 Grade with back to back installation including all accessories like gasket, grub screws etc fixed in position as per instructions of manufacture complete all as specified and as directed.Make : Ozone/ Saint Gobain as approved 74 Supply and fixing reinforing rod 19mm dia at top of showers etc stainless steelincluding all accessories fixed in position as per instructions of manufacture complete all as specified and as directed.Make : Ozone/ Saint Gobain as approved by GE 75 Supply and fixing all types hinges (wall to glass/glass to glass) stainless steel 304 Grade and PSS finish suitable for 10mm glass as in showers complete fixed in position as per instructions of manufacture complete all as specified and as directed.Make : Ozone/ Saint Gobain as approved 76 Supply and fixing all types connectors/ brackets/ catchers etc (L-shaped, wall to glass, glass to glass, floor to glass) stainless steel 304 Grade and suitable for 10-12mm glass as in showers /partitions/doors etc complete fixed in position as per instructions of manufacture complete all as specified and as directed.Make : Ozone/ Saint Gobain as approved 77 Supply and fixing all types patch fittings stainless steel 304 Grade and suitable for 10-12mm glass as in showers/partitions/doors etc complete fixed in position as per instructions of manufacture complete all as specified and as directed.Make : Ozone/ Saint Gobain as approved 78 Supply and fixing Factory made single extruded Pre-laminated WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat with corner round with back grooves of size 50X75 mm”comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp?ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed. Notes: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.(ii) M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately. Make : Alstone / Century / Rajshree 79 Material and labour for providing and fixing factory made single extruded “Pre-laminated WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick” comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face)& 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutterand fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in- Charge all as specified and as directed.Make : Alstone / Century / Rajshree 80 Supply and fixing Stainless Steel matt/glossyfinished (as approved)” butt hinges 100mm long complete all as specified and as directed.Make : Jolly/ Harrison 81 Supply and fixingStainless Steel matt/glossyfinished (as approved)” butt hinges 150mm long complete all as specified and as directed.Make : Jolly/ Harrison 82 Supply and fixing antique/brass finished metal handle 200mm long complete all as specified and directed.Make : Jolly/ Harrison 83 Supply and fixing aluminium alloy anodised extruded fabricated type handle 150mm long complete all as specified and directed.Make : Jolly/ Harrison 84 Supply and fixing aluminium alloy, anodised, barrel tower bolt (bolt type) 150 mm long of extruded section or cast aluminium alloy and fixed complete all as specified and directed.Make : Jolly/ Harrison 85 Supply and fixingStainless Steel matt/glossyfinished (as approved)”200mm long tower bolts in square shaped with minimum 10mm dia rod complete all as specified and as directed.Make : Jolly/ Harrison 86 Supply and fixingStainless Steel matt/glossyfinished (as approved)” curved Handles 200 mm long complete all as specified and as directed.Make : Jolly/ Harrison 87 Supply and fixingStainless Steel matt/glossyfinished (as approved)”Sliding Door Bolt/Aldrop 16 x 300mm with square nuckle complete all as specified and as directed.Make : Jolly/ Harrison 88 Supply and fixing200mm (8 inches) Mortice Lock Set (square shape or as approved) with 60mm one side knob and one side keys chrome polished, with set of 3 nos. of Keys, 2 nos. of handles, 1 no of cyl and 1 no. LB alongwith all accessories/screws etc as required for fixing the same as per manufacturers instructions complete all as specified and as directed.Make : Jolly/Godrej/Harrison or equivalent as approved 89 Material and labour for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed. 90 Supply and fixing aluminium (extruded section) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in repairs complete all as specified and as directed. 91 Supply and fixing 300mm, mild steel ordinary rat tail rod (helical type) pattern springs including roller and roller plate complete all as specified and as directed. 92 Supply and fixing 25mm bore minimum 1mm thick antique/brass finished metal curtain rods with antique/brass finished metal brackets and antique/brass finished metal finials of same manufacturer including screws / rawl plugs as permanufacturers instructions for fixing completeall as specified and as directed.Note : (i) Brackets and finial shall be measured and paid separately for supply only and fixing is deemed to be included in this item.(ii). Design and colour shall be approved by Engineer-in-Charge. 93 Supply and fixing Venetian Blinds with 100% Polyester Fabric of thickness 0.4mm (±5%) and weight not less than 169g/sq.m (±5%) roller type for windows of colour/shade as approved complete fixed in position inclusive S&F matching palmets from same manufacturer and all accessories and hardwares for fixing and operation, all asrecommended by manufacturer, all as specified incl taking down old curtain rods of any type complete all as specified and as directed.Make : D Decor or Vista as approved 94 Supply and fixing vitreous china premium/1st quality wall hung water closet rimless of size 555 x 370 x 365 mm with P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc., and incl. plastic seat cover soft closing type as recommended by manufacturer for particular model closed pattern with flat bottom etc; and incl S&F of all necessary accessories set like rag bolts/gel gasket/hinges etc as recommended by manufacturer for fixing, packing including taking down existing of any description/size complete in all respect all as specified and as directed.Make : Cera (Camel Rimless) or equivalent from Hindware/ Jaquar 95 Supply and fixing concealed flushing cistern of PVC with dual flushing system and half frame, valveless syphonic action type, with inlet/outlet, ball valve, float and including brackets and connection to pipe etc. and incl S&F of all necessary accessories/installation kit and S type drain pipe connetion set for wall hung WC etc as recommended by manufacturer for fixing, packing and including actuator knob/flush plates as approved complete in all respect all as specified and as direted.Make : Cera (Chevron) or equivalents from Hindware/Jaquar as approved by GE 96 Supply and fixing vitreous china premium/1st quality wash down water closet pan floor mounting (pedestal pattern/EWC) with S/P trap snow white colour of size 520X360X390mm including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe and incl. S&F plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including and taking down existing of any description/size complete in all respect all as specified.Note : EWC with S trap will be provided only on G.F. and other remaining floors will be provided with P trap EWCs. Make : Cera (CONVENTIONAL) or euivalent from Hindware/ Jaquar as approved 97 S&F Vitreous China squatting pan of Orissa Pattem of size 580x440mm snow white colour ISI marked, fixed in repairs with integral footrestincluding taking down old unserviceable existing one complete all as specified and directed.Note: The quoted rate shall include provision of P Cast Iron trap complete all as specified and directed.Make : Cera (CALINA S3010102) or euivalent from Hindware/ Jaquar 98 Supply and fixing flushing cistern of Polymer/PVC 10 ltr. cap. with dual flushing system, white colour, valveless syphonic action type, , low level, with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified and as directed.Make : Cera/ Hindware/ Jaquar 99 Supply and fixinghealth faucet with 8mm dia and 1.2 metre long flexible tube in chorme finish and wall hook including making connections and fixed in position complete in all respect as specified and as directed.Make : Cera/Jaquar/Hindware 100 supply and fixing Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed. Make - Cera/Jaquar/Hindware 101 Supply and fixingCP jet for EWC with chrome finished connction pipe including all accessories for fixing complete all as specified and as directed. 102 Supply and fixing Vitreous China premium quality urinal of size 310x300x555mm snow white colour, and connection to inlet and outlet pipe, and incl S&F of all necessary accessories set like rag bolts/gel gasket/hinges etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.Make : Cera (Calorigo) or equivalent from Hindware/ Jaquar as approved 103 Supply and fixing Vitreous China premium quality urinal of size 330x300x450mm snow white colour, and connection to inlet and outlet pipe, and incl S&F of all necessary accessories set like rag bolts/gel gasket/hinges etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete all as specified and as directed.Make : Hindware (Corto) or equivalent from Cera/ Jaquar as approved 104 Supply and fixing Urinal spreader chorme finish for urinals and incl all necessary accessories as recommended by manufacturer for fixing complete all as specified and as directed.Make : Cera, Hindware, Jaquar 105 Supply and fixing vitreous china premium/1st quality Table Top wash hand basin of size 550 x 400 x 160 mm complete all as specified and as directed. Make : Cera (Campa) or equivalents from Hindware/Jaquar as approved 106 Supply and fixing vitreous china premium/1st quality wash basin (under counter), white, size 580x430 mm including all accessories as recommended by manufacturer complete fixed in positionas per manufacturers instructions complete all as specified and as directed. Make : Cera/Jaquar/Hindware Note : The items for counter will be measured and paid separately. 107 Supply and fixing CP Wall mounted basin spout and operating lever quarter turn consisting of exposed part and concealed part complete all as specified and as directed. Make : Cera (F1015653/F4055101) or equivalents from Hindware/Jaquar as approved 108 Supply and fixing Concealed Stop Cock quarter turn, fancy type, CP with long shank and cup, exposed part kit with wall flange, fitting sleeve, operating lever, adjustable wall flange and including regular brass body of concealed stop cock suitable for 15mm line with protection cap fixed in position complete in all respect all as specified. Make : Cera/Jaquar/Hindware 109 Supply and fixing 15 mm fancy type chromium plated quarter turn angle cock/valve with CP wall flange cast copper alloy screwed down high pressure suitable for 15mm bore pipe or union including taking down old unserviceable existing one complete all as specified and as directed. 110 Supply and fixing CP bottle traps 32mm size with 250mm and 175/190mm long wall connection pipes and wall flanges complete fixed in position complete all as specified and as directed. Make : Cera, Hindware, Jaquar 111 Supply and fixing CP waste couplings 32mm size full thread with 80mm height complete fixed in position complete all as specified and as directed. 112 Supply and fixing Stainless Steel Towel Rack 600mm long with lower hangers including all accessories as recommended by manufacturer for fixing and complete fixed in position including taking down existing of any description/size all as specified and as directed. Make : Cera/Jaquar/Hindware 113 Supply and fixing 15 mm fancy type chromium plated quarter turn bib tap of long body with CP wall flange cast copper alloy with crutch or butterfly handles screwed down high pressure suitable for 15mm bore pipe or union including taking down old unserviceable existing one complete all as specified and as directed. 114 Supply and fixing 450mm long braided hose/PVC connection with 15mm brass nuts complete all as specified and as directed. 115 Suppy and fixing 5-Way (3 inlets + 2 outlets) single lever concealed diverter consisting of concealed part and exposed parts CP finish made of brass with all accessories as recommended by the manufacturer connected to 15 GI tubing/ 20mm CPVCincluding CP spout with wall flange of same model and manufacturer complete all as specified and as directed. Make : Cera (Chromo) or equivalent from Jaquar/Hindware 116 Supply and fixing overhead shower 200x200mm square shape with 450mm long brass shower arm with wall flange and incl all necessary accessories as recommended by manufacturer for fixing complete in all respect all as specified and as directed.Make : Cera/Jaquar/Hindware 117 Supply and fixing 5mm thick looking mirror fixed to wall with stainless steel plugs /connecter /spacers/screws etc. chrome finish without any beading, including ends/edges of the mirror to be tapered etched smooth finish etcfixed in position.completeall as specified and as directed. 118 Supply and fixing soap dish,stainless steel of suitable size to accommodate soap , tooth brush glass and tooth paste complete all asspecified and as directed. Make : Cera/Jaquar/Hindware 119 Supply and fixingstainless steel grating 125x125 mm/ 150x150mm size square shaped with self locking arangement for floor trap with or without hole as required fixed in position complete all as specified and as directed. 120 Supply and fixing PVC(HDPE) SWR , 40 mm bore, single socketed in any length with rubber ring joints using solvent cement as per maunfacture instructions including bends/tee/elbow etc. laid in walls for connecting bottle traps complete all as specified and as directed. 121 Taking up or down existing steel tubing and connections, 20mm bore complete all asspecified and as directed. 122 Supply and fixing20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and as directed. 123 Taking up or down existing steel tubing and connections, 25mm bore complete all as specified and as directed . 124 Supply and fixing 25mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified and as directed . 125 Taking up or down existing steel tubing and connections, 15 mm bore complete all as specified and as directed. 126 Supply and fixing 20mm (OD 22.20mm) CPVC pipes SDR 11, class-1 for potable hot and cold water distribution supplies lead free confirming to IS-15778 laid on walls/ceiling or laying in floors jointed with suitable CPVC solvent cement of same manufacturer including all CPVC SDR 11 fittings as required andsuitable for fixing 15mm CP faucets/ fixtures complete all as specified and as directed.Make : Supreme, Finolex, SFMC, Prince 127 Supply and fixing 25mm (OD 27.20mm) CPVC pipes SDR 11, class-1 for potable hot and cold water distribution supplies lead free confirming to IS-15778 laid on walls/ceiling or laying in floors jointed with suitable CPVC solvent cement of same manufacturer and incl all CPVC SDR 11 fittings as requiredcomplete all as specified and as directed.Make : Supreme, Finolex, SFMC, Prince 128 Supply and fixing female Brass Threaded Adaptor (FTA/ FBTA) for 20mm dia CPVC pipe all as specified and as directed. 129 Supply and fixing Brass elbow (3/4 x 1/2) for 20mm dia CPVC pipes completeall as specified and as directed 130 Supply and fixing ISI marked doubled layered rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top / cover) 1000 Ltrs capacity hoisted and fixed in position all as specified including 20 mm dia brass float valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC water tank complete all as specified and as directed. Make :Sintex/Diplast/Sheetal/Supreme 131 Supply and fixing ball brass valves, high pressure, with polythene float and flynut complete, screwed for 20mm bore iron pipe or brass ferrule and fixed in repairs complete all as specified and as directed. Make : ZOLOTO, L&T Valves 132 Supply and fixing ball brass valves, high pressure, with polythene float and flynut complete, screwed for 25mm bore iron pipe or brass ferrule complete all as specified and as directed.Make : ZOLOTO, L&T Valves 133 Dismantling of sewage pipe of any size and descriptionfrom any position jointed in cement mortar and taking out of trenches if required complete all as specified and as directed. 134 Dismantling and taking down bends /floor traps /nahani traps /tee / branch pieces / cowls etc of any/size/description jointed in cement mortarfrom any position complete all as specified and as directed. 135 Supply and fixing uPVC (SWR) floor traps confirming to IS : 14735-99 and as per international standards with 110mm bore outlet including jointing with lubricant/ PVC cement solvent as per manufacturer’s instruction to UPVC waste pipe fixed in cement concrete 1:2:4 type B-2 complete all as specified and directed.”Note:The quoted rate shall include embedding the floor trap incement concrete 1:2:4 type B-2 block of size 300x300x250 mm 136 Suppy and fixing uPVC (SWR) floor traps confirming to IS : 14735-99 and as per international standards with 75mm bore outlet including jointing with lubricant/ PVC cement solvent as per manufacturer’s instruction to UPVC waste pipe fixed in cement concrete 1:2:4 type B-2 complete all as specified and directed.”nt/ PVC cement solvent to PVC waste pipe fixed in cement concrete 1:2:4 type B complete all as specified and as directed.Note: The quoted rate shall include embedding the floor trap incement concrete 1:2:4 type B-2 block of size 300x300x250 mm 137 Supply and fixing uPVC (SWR) Nahni traps confirming to IS : 14735-99 and as per international standards with 75mm bore outlet including jointing with lubricant/ PVC cement solvent as per manufacturer’s instruction to UPVC waste pipe fixed in cement concrete 1:2:4 type B-2 complete all as specified and directed.”Note: The quoted rate shall include embedding the floor trap incement concrete 1:2:4 type B-2 block of size 300x300x250 mm 138 Supply and fixing uPVC (SWR) Type-B pipe single socket 110mm bore confirming to IS 13592-92 in any length with including jointing with lubricant/ PVC cement solvent as per manufacturer’s instruction to UPVC waste pipe, fixed to wall ,including stack clamps out of 50x5 mm flat and 16 mm dia iron stays, including bolts and nuts etc and making necessary connections complete all as specified and as directed.” 139 Supply and fixing uPVC (SWR) Type-B pipe single socket 110mm bore confirming to IS 13592-92 in any length with including jointing with lubricant/ PVC cement solvent as per manufacturer’s instruction to UPVC waste pipe, laid in trenches/floorand making necessary connections complete all as specified and as directed.” 140 Supply and fixing uPVC (SWR) Type-B pipe” single socket 75mm bore confirming to IS 13592-92 in any length “with lubricant/ PVC cement solvent as per manufacturer’s instruction”fixed to wall ,including stack clamps out of 50x5 mm flat and 16 mm dia iron stays, including bolts and nuts etc and making necessary connections, complete all as specified and as directed. 141 Supply and fixing uPVC (SWR) Type-B pipe” single socket 75mm bore confirming to IS 13592-92 in any length “with lubricant/ PVC cement solvent as per manufacturer’s instruction” laid in trenches/floor and making necessary connections, complete all as specified and as directed. 142 Supply and fixing uPVC (SWR) confirming to IS : 14735-99 and as per international standards ” bend 110mm bore pipes (any radius) with access door fixed “with lubricant/ PVC cement solvent as per manufacturer’s instruction”complete all as specified and as directed. 143 Supply and fixing uPVC (SWR) confirming to IS : 14735-99 and as per international standards ”bend 75mm bore pipes (any radius) with access door fixed “with lubricant/ PVC cement solvent as per manufacturer’s instruction”complete all as specified and as directed. 144 Supply and fixing uPVC (SWR) confirming to IS : 14735-99 and as per international standards ” double branch door Tee suitable for 110mm bore pipes ISI marked fixed“with lubricant/ PVC cement solvent as per manufacturer’s instruction” complete all as speciied and as directed. 145 Supply and fixing uPVC (SWR) confirming to IS : 14735-99 and as per international standards ”Single door Tee suitable for 110mm bore pipes ISI marked fixed “with lubricant/ PVC cement solvent as per manufacturer’s instruction”complete all as speciied and directed. 146 Supply and fixing uPVC (SWR) confirming to IS : 14735-99 and as per international standards ”Single door Tee suitable for 75mm bore pipes ISI marked fixed “with lubricant/ PVC cement solvent as per manufacturer’s instruction”complete all as speciied and as directed. 147 Supply and fixing uPVC (SWR) confirming to IS : 14735-99 and as per international standards ” Cowls for 110mm bore pipes fixed “with lubricant/ PVC cement solvent as per manufacturer’s instruction”complete all as specified and as directed.. 148 Supply and fixing uPVC (SWR) confirming to IS : 14735-99 and as per international standards ” P or S trap 110mm bore with long arm ISI marked fixed “with lubricant/ PVC cement solvent as per manufacturer’s instruction”complete all as speciied and as directed. 149 Supply and fixing uPVC (SWR) confirming to IS : 14735-99 and as per international standards ”gully trap 125/110 mm setting and jointing “with lubricant/ PVC cement solvent as per manufacturer’s instruction” complete all as specified and as directed. 150 Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. 151 Material and labour for water proofing treatment to sunken floor with depth not exceeding 450mm with the following course of treatment/ specification:-(i) Cleaning top surface of floors /slabs and laying 100 mm thick (avg) PCC of grade M10 (Nominal mix) , mixed with WPC as per manufactrrers instruction laid in slope 1:20 towards spouts including coveting corners(ii) 15 mm thick plastering in CM (1:4) on sides mixed with WPC as pe rmanufacturers instruction. (iii) Applying 1st layer of slurry @ 0.488 kg / sqm mixed wth acrylic based polymer modified cementious compound @ 0.253 kg /sqm This layer shall be allowed to air cured for 4 hrs. (iv) Applying 2nd layer of slurry @ 0.242 kg/sqm mixed with accrylic based polymer modified cementenous compound @ 0.126 kg/sqm.This layer shall be allowed to air cured for 4hrs followed with water curing for 48 hrs. (v) Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces (vi) Providing 150 micron thick polyutethene paint in two coats (each of 75 micron measured dry on dry surface over a coat of PU primer including preparation .(Make of PU primer - Dek guard EP -302 of M/S Fosroc or equivalant approved brand.Make of PU paint - Dek guard PUor equivalant approved brand. (vii) 2 Nos 40mm bore GI medium grade 450mm long spout ,to be provided through external wall to drainout accumulated water. (viii) Sunken floor shall be tested for water tighness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage /seepage exists (ix) Sunken portion shall be filled with lean concrete of grade M7.5 stone agreegateNote : Only top/finished horizontal surface will be measured for the payment purpose. 152 Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillet complete all as specified and as directed. 153 Supply and fixingWPC Louvers / WPC Wall panelling of fluted / louvers / hollow sections / (colour/pattern as approved by AO) of any size and description complete fixed in position in all respect including all accessories like fasteners/ screws/solvent/ fillets etcl as recommended by manufacturer complete all as specified and as directed. 154 Supply and fixing PVC Wall panelling of fluted/louvers/hollow sections/ (colour/pattern as approved by AO) of any size and description complete fixed in position in all respect includingall accessories like fasteners/ screws/solvent/ fillets etc all as recommended by manufacturer complete all as specified and as directed. 155 Material and labour for 3mm thick ACP sheets of any colour as approved in wall cladding/ceiling etc. with 12mm groove of silicon water proof and covering all screws on ACP by silicon including aluminium frame work of section 40x25 mm and 14 gauge thickness fixed to existing wall/structure with 75 mm stainless steel screw and membres interconnected with 40/20mm stainless steel screw, also including all necessary use of all double line scaffolding, trestle , ladders, cradles etc. necessary for execution of work and protective measures including hoisting and lowering fixed to frame work at height n exc 8mtr all as specified and as directed.Make : Alstone or equivalent as approved 156 Supply and fixing anodised aluminium snap grid frame work (size of grid 605x605mm) for false ceiling all as specified including hangers 6 mm dia. G.I. (upto 1200mm length)adjusting level fixed to roof slabs by means of ceilling cleats made out of G.l. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. Make: Armstrog/Gyproc or Equivalent as approved. 157 Material and labour for 12 to 12.50mm thick semi-perforated/pin holed particle board/tiles, 600x600 ± 5 mm in size fixed in false ceiling as per manufacturers instructions to existing frame work or on snap grid as in repairs complete all as specified and as directed.Make: Armstrog/Gyproc or Equivalent as approved. 158 Material and labour for dismantling of MS like asnewels, Balustrades including wood hand rails and all similar items all as specified and as directed. 159 Supply and fixing fabricated Stainless steel Tubes (Rectangular/Square/Circular in shape) of Grade 304 for newels, Balustrades, railings, cap, top hand ralling along the length and intermediate section and all similar works including Rubbing/Polishing all as specified and as directed. 160 Supply and fixing MS hollow rectangular/square/circular tubes/pipes of YST 310 Grade as in frame work for cooler stands /roofs /rafters /purlins /chajjas/trusses/ columns/ struts etc and like similar items etc. complete all as specified and as directed. 161 Material and labour for preparation of steel and iron surfaces of any description nor otherwise described over 10 cm width or girthincluding purlins/ rafters/ trusses/ columns/ struts/railings/ blusterades/ cooler stands/ any frame work etc and the like works and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.Make : Asian Paints/Berger/Nerolac 162 Supply and fixing stainless steel sheet of 250 mm wide and not less than 1mm thick as in crumple/ expansion joints all as specified and as directed. 163 Supply and fixing18mm thick high Density High Moisture Resistant (HDHMR) exterior Grade Board with both side white balancing (BSB) with density of 850 Kg/cu.m complete all as specified and directed.Make : Action Tesa/ Greenpanel/CenturyNote : Board on back side wall will be fixed with minimum 5mm PVC spacers/buffers. The payment for the same deemed to be included in the quoted unit rates. 164 Supply and fixing 18mm thick high Density High Moisture Resistant (HDHMR) exterior Grade Board with one side designer laminate (OSL) of approved colour and finishing and other side whitebalancing with density of 850 Kg/cu.m complete all as specified and as directed. Make : Action Tesa/ Greenply/Century 165 Supply and fixingBall bearing runners 45 mm Telescopic (KTS-20) full extension load capacity 50 kgs complete all as specified and as directed. Make: KAFF/Hettich 166 Supply and fixing Piano/continuous hinge of size 19 mm stainless steel complete all as specified and as directed. 167 Supply and fixing ball catchers 304 grade stainless steel finished suitable for cabinets premium quality complete fixed in position as per manufacturers instructions complete all as specified and as directed. Make : Hettitch or equivalent as approved. 168 Taking down of existing steel door of size exc 2.0 sq.m and n. exc. 3.0 sq.m of any description/ weight with hold fasts and refixing in same position with filling the hold fast with 1:2:4 PCC of min size 23x20x20 cm with minor repairs/ welding etc all as specified and as directed. 169 Suply and fixing 12mm thick HDF Board both side decorative compact laminate fire retardent/ termite proof / BWP borer proof of Approved colour, shade side as in cubical with 10 years Guarantee for the door against any moisture cubical complete including the following :- (1) Stainless steel adjustable shoes/ legs 316 grade 150mm high - 02 Nos. (2) Stainless steel gravity hinges 304 grade -3Nos.(3) Stainless steel coat hook 304 grade - 1 Nos.(4)Stailnless steel door knob 304 grade-01 Nos. (5)Stainless steel indicator lock 304 grade -01 Nos. (6)Profile U-Channel (Aluminium Powder coated ) length 1.82mm (6feet) each-02. (7) Door stop (Aluminium powder coated) length 1.82mm (6feet) each-02. (8)Noise defending tape/gascut rubberlength 1.82mm (6feet) each-01. (9)Hollow circular pipe of aluminium powder coated of size 30/40mm for top rail of cubicals.(10) Corner connected , wall brackets , S-S screw and wall plugs as required.Make:12mm board action tesa/Greenlam etc and fixed in position completeall as specified and as directed. 170 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out as in soft/loose soil complete all as specified and as directed 171 Material and labour forHardcore of broken stone or bouldergauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface completeall as specified and as directed. 172 Material and labour for cement concrete 1:4:8 typeD-2 (using 40 mm graded stone aggregates.) as in sub base under floors complete all as specified and as directed. 173 Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. 174 Material and labour for cement concrete 1:2:4 type B-0 using 12.5mm graded mechanically crushed stone aggregate as inbenching, rounded or chamfered on edges, coving shall be 150 mm in radius complete all as specified and as directed. 175 Removingthe excavated material soiln exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. 176 Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings size as switches, ceiling rose, pendant, regulator, sockets, light fittingetc. removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed. 177 Material and labour for Point wiring (concealed) with 1.5 Sqmm(Nominal area) PVC insulated and PVC unsheathed FRLSH multi stranded copper conductor single core cable drawn through and including PVC non metallic conduit of 20 mm diaISI marked with complete accessories, including sunk/pressed metal flush box mild steel1.6 mm thick terminal boxes with white moudular cover plate with frame for mounting of switches.sockets/fan regulators etc .ISI marked complete including PVC insulated and unsheathed single core multistranded copper conductor cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth and earth dolly, making good surface with white wash or any type distemper as per existing colour of buildingcomplete all as specified and directed including in ceiling portion surface conduit wiring to be done for the following :- (a) One lightpointcontrolled by oneone way switch. 178 (b) One fan pointcontrolledby one one way switch. 179 (c) One bell/buzzer point controlled by one push button. 180 (d) One 3/5 pin socket outlet 5 Amp on the same board with other swithes. 181 (e) One 3/5 pin 5 Amps socket outlet on indepandant board. 182 (f) One light point controlled by two two way switches 183 Allas per serial item No 177 here-in-before but with 2.5 Sqmm (nominal area) FRLS cable PVC for the 15 Amp 3/5 pinsocket power point including 2.5 Sqmm copper conductor green as colour for earth contineuity complete all as specified and as directed. 184 Taking down sub main wiring and Supply and fixing Sub main wiring with two runs of single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable of size 6.0 sqmm LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 20mm/approprite dia with accessories and fittings and one run of 6.0 sq mm single core multi stranded copper conductor cable as earth continuity conductor comlete all as specified and as directed. Notes:-(i) Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm/approprite dia shall be measured as one run length,(II) Cable required for connection to DBs shall deemed to be inclusive and shall not be measured separately.(iii) Earth wire shall run inside the conduit pipe(iv) Extra length of cable required for connection to MCBs shall deemed to be included in unit rate. Make of Cable:- Plaza/Havells /policab, Make of PVC conduit - Kinjal/atul/plaza Plast/Kalinga 185 Supply and fixing in replacement of modular switch single pole one way 5/6 Amps, one module complete all as specified and as directed. 186 Supply and fixing in replacement of modular switch single pole one way 16 Amps, one module complete all as specified and as directed. 187 Supply and fixing in replacement of modular switch single pole two way 5/6 Amps, one module complete all as specified and as directed. 188 Supply and fixing in replacement of modular type, socket6 Amps, 2/3 pin combined 2 module complete all as specified and as directed. 189 Supply and fixing in replacement of modular type, socket 6/16 Amps- 2/3 pin combined2 modular complete all as specified and as directed. 190 Supply and fixing modular type, Bell push 1 way, 6 Amps, 1 module complete all as specified and as directed. 191 Supply and fixing Bell electric AC 230 Volts single pole ding dong type complete all as specified and as directed. 192 Materia land labourfor Ceiling rose, 3 phasepoly carbonate isolated body 3 terminal brass flush type 6 Amps,250 volts ACISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified and as directed. 193 Supplyand fixing In replacement of old unserviceable modular fan regulator 230 volts,120 watt,- 2 module, step type (5 step) socket type complete all as specified and as directed. 194 Supply and fixingAngle holders (metal ring) PVC / polycarbonate type with back plate, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm diacompleteall as specified and as directed. 195 Supply and fixing In replacement of old unserviceable light fittings LED tube light fitting 1x20 Watt box type industrial batten typewithbipin holders connector block complete with all accessories internally prewired including connection with three core flexible copper conductor cable of suitable size and provision ol 01 No. 20 wattretrofit LED tube rod T8 polycabonate complete all as specified and as directed. 196 Supply and fixing In replacement of old unserviceable security light fittings, versatile pressure die-cast aluminium with high power LED 35 W as light source complete with LED 35 W 5000Kincluding bracketsmade out of 40 mm bore GI pipe light gradebent to shape including 02 Nos MS clamps made out of 50x5 mm flat iron including bolts,nuts and connection with three core flexible copper conductor cable of suitable sizecomplete all as specified and as directed. 197 Supply and fixing In replacement of old unserviceable surface mounting light fittings round shape 15 watt with high efficiencydiffusere soft glare free light complete with driver, holders, LED lamp suitble for roof ceiling including connecting with three core flexible copper conductor cable of suitable size complete all as spd and directed . 198 Supply and fixing In replacement of old unserviceable distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,single pole and neutral 250 volts ,flush to wall complete all as specified and as directed 199 Supply and fixing In replacement of old unserviceable distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof VTPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar,earth bar ,triple pole and neutral 415volts , flush to wall complete all as specified and as directed. 200 Supply and fixing In replacement of old unserviceable MCB single pole,6 to 32 Amp 240 volt B curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area completeincluding suitable sizecopper Lugs complete all as specified and as directed. 201 Supply and fixing In replacement of old unserviceable Miniature circuit breakers C curve ISI marked 240 Volt, 50 Hz, SPN 32 Amps, breaking capacity 10 KA B.complete all as specified and as directed. 202 Supply and fixing In replacement of old unserviceable Miniature circuit breakers (MCBs) ,B curveISI marked 415 Volt, 50 Hz, TPN 100 Amps, breking capacity 10 KA.complete all as specified and as directed. 203 Material and labour earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4mm dia size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 ofSSR-2009 Part I and includingnecessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) (chamber size not less than 300x300x300mm interier diamentions), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15cm c/c both way for cover and MS frame etc complete all as specified and directed.NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. and chamber shall be made 0.5 mtr away from the earthing pit. 204 Supply and fixing LED lamp 12 watt B22 CDL inverter bulb complete all as specified and as directed. Make : C&S/Havells/Surya 205 Supply and fixing rigid non-metallic PVC conduit of size 20 mm dia exclusive of boxes ( junction/terminal) but inclusive of all tees,bends,elbows,reducers,bell mouth tube ends and fixing accessories such as couplers ,lock nuts, saddles, pipe hooks etc. complete all as specified and as directed . 206 Supply and fixing in replacement ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.Note:- Old u/s C/Fan to be deposited in MES store. 207 Supply and fixing in replacement exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louvers, BEE, five star rated including fixing the fan with all connecting accessories and making electric connection from c/rose etc.including making suitable size hole in wall built in cement mortar and groutinganchor bolt for fixing Exhaust Fan on walland making good the disturbed surface to match the existing surface complete all as specified and as directed..Note:- Old u/s C/Fan to be deposited in MES store. 208 Supply and fixing in replacement PVC exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louvers, BEE, five star rated including fixing the fan with all connecting accessories and making electric connection from c/rose etc. including making suitable size hole in wall built in cement mortar and groutinganchor bolt for fixing Exhaust Fan on walland making good the disturbed surface to match the existing surface complete all as specified and as directed.. Note:- Old u/s C/Fan to be deposited in MES store. 209 Supply and fix in replacement of Recess mounted LED luminaire with more light distribution and clutter free ceilings of 36 watt suitable for gridd celling Cutout dimensions: 2 x 2 Model : Immaculate LED Trimlesscomplete all as specified and as directed 210 Supply and fixing in replacement of existing unserviceable SP&N enclosure with 2 pole and Earth Metal Plug & Socket for incorporating 10A / 20A SPN / DP MCB With Plastic Cover earthcomplete with one single pole MCB of 20 Amp complete all as specified and as directed 211 Supply and fixing 18 Watt square surface mounted LED panel PDC, aluminium housing and high tranlucent frosted plastic diffuser of luminair efficiancy 100 lumen per watt incluidng making electircal connections from ceiling rose to mirror light with suitable size of electrical cable and making good the disturbed surfaces to match the existing surface complete all as specified and as directed. 212 Supply and fixing In replacement of old unserviceable XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt gradecross sectional area 70 Sqmm and 3.5 core complete all as specified and as directed 213 Material and labour for laying GI tubinglight grade 80 mm bore dia with all fittings for cable protection including GI clamps nut bolts and washer etc all as specified and as directed. 214 Material and labour for excavation in trenchesn.exc 1.5 mwidth and n.exc 1.5 m in depthin any type of soil/strata for foundations, poles.Struts,laying cable etc and getting out completeall as specified and as directed . 215 Returning, filling in any type of soil including spreading , leveling , wateringand well rammming in layers n.exceeding 25 cmthick complete all as specified and as directed. 216 Removing excavated any type of soil from site to a disdance not exceeding 50 mtrs and depositing where directed at level not exceeding1.5 mtr above the starting point complete all as specified and as directed. 217 Material and labour forsand cushioning for UG cables using dry fine river sand, 8 cm below the cable and 15 cm above the cable in trenches including spreading, levellingcomplete all as specified and and directed.Note: Only punned thickness shall be measured for payment. 218 Material and labour for old sizewell burnt,sub class B bricks laid flat, dry in trenches perpendicular to the direction of cable for cable protection complete all as specified and as directed. 219 Supply and fixing Change over switch 100 Amps 4 Pole 440 Volts off line type complete all as specified and as directed. Make : C&S/Havells/L & T 220 Supply and fix in repairs erecting in true verticle position of steel tublar swaged poles completecomplete with cast iron base plate, finial taper, plug, bolt, nuts and screws as as specifiedtype 410 SP-31(9.00 metres long) conforming to relevent IS including applying two coats of aluminium paint over one coat of red oxide primer to the full length of the pole and also two coats of bituminus paint inside outside of bottom portion upto 1.5 mtrs length and fixing 01 No. circular bend 32 mm bore GI light grade 2 mtr length bracket fixed with 50x5 mm flat iron clamp on pole for mounting LED security light all as specified and as directed.Note:- Excavation,earth work and PCC shall be measured and paid separetaly. 221 Material and labour for cement concrete 1:4:8 type D-2 using 40 mm graded broken stone aggregate as in foundations,filling and mass concretecomplete all as specified and as directed. 222 Material and labour for cement concrete 1:2:4 type B-I using 20 mm graded broken stone aggregate as in foundations,filling and mass concretecomplete all as specified and as directed. 223 Material and labour for cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement complete all as specified and as directed. 224 Supply and fixing LED street light fitting 120 watt 230 V AC outdoor type with high pressure aluminium die cast housing and heat resistat complete with driver ,lamopbracket and impact and corrosion resistant including thermal management in multiple optics complete with IP66 protection complete all as specified and as directed. 225 Supply andfixing in replacement Led post top fitting 40W powder coated aluminium die cast and spun aluminium with clear/ opal diffuser suitable for landscape lighting in IP65 including GI Pipe of suitable dia and height reqd at site including PCC work and connection properly with existing LT OH line or From main MCB DB complete all as specified and as directed. 226 Supply and fixing in replacement Led post top fitting 20W powder coated aluminium die cast and spun aluminium with clear/ opal diffuser suitable for landscape lighting in IP65 including GI Pipe of suitable dia and height reqd at site including PCC work and connection properly with existing LT OH line or From main MCB DBcomplete all as specified and as directed. 227 Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor of sizef 10 Sqmm, 2 core complete all as specified and as directed. 228 Supply and fixingair ternimation,single pointed aluminum rod, 12 mm dia and 300 mm long complete all as specified and as directed 229 Supply and fixing aluminium strip 25 mm x 3.15 mm compete with saddles and fixing screws etc for for roof conductor and down conductors above ground complete all as specified and as directed . 230 Supply and fixing galvanised iron strip 32 x 6 mm burried in ground complete all as specified and as directed 231 Material and labour for Test point terminal block for lightening conductors made out of gun metal or phosphorus bronze size of 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexa head screws including connecting with earthing and GI/Aluminium strips complete all as specified and as directed. 232 Material and labour for earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below noral ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in altenate layers and electode connected to galvanized iron strip 32x6 mm dia size dia size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate nNo 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) (chamber size not less than 300x300x300mm interier diamentins), tpe C-1 chamber, RCC (1:2:4) type B-1, reinforced with 6mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc, complete all as specified and as directed. Note : The unit rate includes earth strip and protection pipe upto (Maximum 7.5 metre from earth plate) earth point/test point. and chamber shall be made 0.5 mtr away from the earthing pit.
Contract Date: Jan 05, 2026 Contract Value : 1.25 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
24.
Rural Development #8519282 AOC
Tender For Lwm Under Sbm Gramin Ii Theur Tal-Havelidist-Pune - TIGER BIO FILTER (300 KLD ) 1 UNIT Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 0.0 to 1.5 m 2 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259)0.0 to 1.5 m 3 1.5 to 3.0 m 4 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 1.5 to 3.0 m 5 3.0 to 4.5 m 6 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) 3.0 to 4.5 m 7 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 8 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 9 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 10 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 11 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 12 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) c) Corrosion Resistant Steel (Fe 500) 13 Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) 14 Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer-in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 15 Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B .W .G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts , lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 16 Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 17 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 18 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curingcomplete. 19 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 20 Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 21 Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 22 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 23 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 24 Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle (50 x 50 x 6 mm) postat 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in (1:4:8) cement concrete block of 45 x 45 x 45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete 25 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH-PL/STP 26 Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 27 Fine and Coarse Screen (Manual) of size 1.65 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. 28 Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 1 HP (Up to 9000 LPH) Supply 29 Erection 30 Raw Sewage Pumps Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 3 HP (Up to 18000 LPH) Supply 31 Erection 32 NaOCl Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10LPH Power Source Electric - Phase Single Material PP / PTFE(Teflon) / Voltage 230 Volt / Frequency 50Hz / Mixing Tank of 20 Ltrs capacity- 1 No / Dosing Pump - 1 Nos 33 Raw water pump MCCB Panel Boards Providing & erecting floor/wall mounted MCCB panel board, with door, suitable for four pole incoming 250A, 2 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) Supply 34 Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser.> 7.5 HP & Up to 12.5 HP Supply 35 Main power supply cable - Main DP to Control Panel cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed.3 core 16 sq mm Supply 36 Erection 37 Power cables Aluminium conductor 4 Core, XLPE / PVC insulated & armoured cable Supplying and erecting, XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 6 sq mm Supply 38 Erection 39 Control Cables Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner. 4 core 2.5 sq mm Supply 40 Erection 41 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent).1) 10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only.2) One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates below. Working Pressure 6 Kg/Sq.cm Raw Sewage pump to TBF Distribution Main header 75 mm. 42 PVC Specials- 10% 43 TBF Distribution 50 mm 44 PVC Specials- 10% 45 TBF Bed Distribution Distribution line for sripnklar 20 mm 46 PVC Specials- 10% 47 Collection Tributory + Drain Pipe 75 mm. 48 PVC Specials- 10% 49 Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint).63 mm, 50 mm and 20 mm uPVC pipe 50 Sluice valves Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 51 Reflux valves (non-return valves ) Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 52 Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.(Rate for all class of valves.) Sluice valves 53 Reflux valves (non-return valves ) 54 Ball Valve Plastic (Heavy Body) 55 Supplying ofSpecially designed container for holding Bio media including mixture of cocohusk,bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. 56 Stone Aggregate --5 mm to 10 mm 57 20 mm 58 40 mm 59 Transportation as per STATEMENT VI Including loading, unloading and stacking Aggregate 40 mm & above (25 Km) 60 Detailed Process Designing, Technology charges and commissioning of Sewage Treatment Plant (STP)based on Tiger Bio Filter (TBF) technologyas turnkey job
Contract Date: Dec 30, 2025 Contract Value : 66.87 Lakh
Government Departments No of Bidders 4
Maharashtra View Result →
25.
Civil Aviation #8495667 AOC
Tender For Miscellaneous Electrical And Mechanical Works (2025-26) At Various Locations Of Aai, Bangalore; 1 SH I : SITC of LED light fittings and Ceiling fans. 2 Supplying of 2X2 recess mounting LED type luminaire having minimum 3600 lumens output complete with electronic driver, made out of powder coated CRCA/Aluminium housing suitable for operation on 230 Volt, 50 HZ AC complete as per technical specifications and with Five (5) year manufacturer warranty (for complete assembly) [Bajaj BZRSQL 36L/Halonix HLFPR22-11-36CW/Orient LTRAQ-36-C-FC or equivalent from list of preferred makes] 3 Supplying of 2X2 recess mounting LED type luminaire having minimum 3600 lumens output complete with electronic driver, made out of powder coated CRCA/Aluminium housing with colour tuning of 6500K, 4000K and 3000K and RF based dimmable driver for intensity control from 0 to 100% in 4 or more steps along with suitable programmable remote control etc suitable for operation on 230 Volt, 50 HZ AC complete as per technical specifications and with Five (5) year manufacturer warranty (for complete assembly)[Halonix HLFPR22-06-36CW-HC-RFD/ARRAYSTORM METAL GENISYS or equivalent from list of preferred makes] 4 Supply of Recess mounted LEDdownlight luminaire (Round Profile) having minimum 1800 lumen output complete with electronic driver, made out of powder coated CRCA/Aluminium housing suitable for operation on 230 Volt, 50 HZ AC complete as per technical specifications and with Five (5) year manufacturer warranty (for complete assembly)[Bajaj BGSLO RD 18W/Halonix HLDLR22-06-18CW/Orient LDRER18-C-V1 or equivalent from list of preferred makes] 5 Supply of 1X18W Surface/Wall mounted LED type luminaire with LED tube and driver suitable for 230 volts, 50 Hz, AC supply etc complete along with all accessories etc as per technical speciciations and with Five (5) year manufacturer warranty (for complete assembly)[Bajaj BLRB-DB-118/Halonix HLIB-05-118-LED-1S or equivalent from list of preferred makes] 6 Supply of 2X18W Surface/Wall mounted LED type luminaire with 2 nos of LED tube and driver suitable for 230 volts, 50 Hz, AC supply etc complete along with all accessories etcas per technical speciciations and with Five (5) year manufacturer warranty (for complete assembly) [Bajaj BLRB-DB-218/Halonix HLIB-05-218-LED-1S or equivalent from list of preferred makes] 7 Supplying of Industrial bulk head type luminaire having minimum 1100 lumens output complete with electronic driver, made out of powder coated CRCA/Aluminium housing suitable for operation on 230 Volt, 50 HZ AC complete as per technical specifications and with Five (5) year manufacturer warranty (for complete assembly)[Bajaj BIBWP10W/Halonix HLBH02-10CW/Orient LIBHP-10-C-V1 or equivalent from list of preferred makes] 8 Supply of LED Decorative post top light fitting for indirect light with IP 65 protection, resistant to impact and corrossion, glare free and better uniformity having minimum output of 3000 lumen with electronic driver, etc. and suitable to operate on 230V, 50Hz single phase AC supply etc complete as per technical speciciations and with Five (5) year manufacturer warranty (for complete assembly) . (Make: Bajaj BGCTNP 40W LED WH / Halonix HLPT-04H-30 CW/Orient LLAS 30C or equivalent from list of preferred makes) 9 Supply of LED highbay luminaire in dust and vermin proof housing made out of high pressure die cast aluminium/ standard alloy (IP65 or higher) having minimum 10400 lumen output, proper thermal dissipation, wider beam optics and suitable to operate on 230V, 50 Hz single phase AC supply with electronic driver and having surge protection etc, completeas per technical speciciations and with Five (5) year manufacturer warranty (for complete assembly)[Bajaj BGHBM .nxt BL 104L WH SY SD/Halonix HLBLD-ML54-100-CWL-R-P/Orient LHPNP-080-C or equivalent from list of preferred makes] 10 Supply of LED flood light luminaire having minimum lumen output of 10400 lm designed with energy saving, environmental friendly, long life LEDs, integral driver with surge protection, High Pressure die-cast aluminium housing with minimum IP65 Protection, frame including all accessories etc complete as requiredas per technical speciciations and with Five (5) year manufacturer warranty (for complete assembly)[Bajaj PRAZE F 120L WH NB-A5 TG SD/Halonix HFFLD-ML27-100-CWDL/Orient LFAP-100C or equivalent from list of preferred makes] 11 Supplyof outdoor type LED streetlightfixture having lumen output not less than 10800 lumens, pressure die cast extruded aluminium/aluminium alloy housing, heat sink with general spread optics , IP-65 or higher, including accessories such as LED of approved make, electronic gear/driver with surge voltage, etc suitable for operation on 140 V to 280 V AC etc. complete as per technical specifications and with Five (5) year manufacturer warranty (for complete assembly) [Bajaj ZELA P 108L WH PO TG SD/Halonix HLSLD-E1-90CWDL-R01/Orient LSFS-090-C or equivalent from list of preferred makes] 12 Supplyof outdoor type LED streetlightfixture having lumen output not less than 3600 lumens, pressure die cast extruded aluminium/aluminium alloy housing, heat sink with general spread optics , IP-65 or higher, including accessories such as LED of approved make, electronic gear/driver with surge voltage, etc suitable for operation on 140 V to 280 V AC etc. complete as per technical specifications and with Five (5) year manufacturer warranty (for complete assembly)[Bajaj ENXT P 30L WH PO PC SD/Halonix HLSLD-E1-30CWDL-R01/or equivalent from list of preferred makes] 13 Installation, testing and commissioning of recessed type LED fittings of all types complete with all accessories like GI chain etc. including modification/cutting/finishing of existing cutouts of gypsum false ceiling to install the new fittings, connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. complete as required as per actual site requirements. 14 Installation, testing and commissioning of surface/ wall mounted indoor type LED fittings of all types complete with all accessories including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. complete as required as per actual site requirements. 15 Supply and fixing of 32/40mm dia X 1.20 metre long G.I. pipe (medium class) bracket for mounting of LED street light fitting on pole/wall including bending the pipe to the required shape, accessories such as clamps with nuts, bolts and washer etc. as required. 16 Installation, Testing and Commissioning of LED street light/flood light/post top luminaire of all capacities on the existing bracket of pole/wall of height upto 10mtrs including all accessories, connections with suitable size PVC insulated copper wires etc as per site requirements complete as required 17 Supply and fixing of suitable thickness transparent acrylic sheet for covering the 450mm dia housing of street light fixture along with all required fixing accessories complete as required. 18 Supply, Installation, Testing and Commissioning of 1400 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 235 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. i/c providing necessary clamping and hanging arrangement for installtion on existing metallic structure etc complete as required. 19 Supply of 450mm sweep Air Circulator type Pedestal Fans including all accessories suitable for operation on 230V, 50Hz AC supply. 20 Supply of 450mm sweep Air Circulator type Wall Fans including all accessories suitable for operation on 230V, 50Hz AC supply. 21 SH II : SITC of LT Cables, LT Switchgears and SPDs 22 Supplying of Aluminium conductor PVC insulated and PVC sheathed/XLPE , steel strip armoured power cable of 1.1 Kv grade confirming to IS:1554 (Part-I) of following sizes. 23 4C x 10 Sq.mm 24 Supply of 50mm dia (OD) HDPE pipe of PN 6, PE 80 grade conforming to IS: 4984 complete as per specifications and as required. 25 Laying of DWC/HDPE pipe upto 63mm OD along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc.along existing duct (with openable concrete slab covers) etc. completeas required. 26 Laying of DWC/HDPE pipe upto 63mm OD along with all accessories like socket, bend, couplers etc. complete with fitting, cutting, jointing etc. in soft soil(75 cm below ground level), excavation and refilling the trench but excluding sand cushioning, protective covering etc. completeas required. 27 Laying of DWC/HDPE pipe 50mm OD along with all accessories like socket, bend, couplers etc. complete with fitting, cutting, jointing etc.under bitumenous/concrete surface (75 cm below ground level) including dismantling/cutting the concrete surface/bitumen surface, excavation and refilling the trench, finishing the top surface with cement concrete 1:3:6 but excluding sand cushioning, protective covering etc. completeas required. 28 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 29 Upto 35 sq. mm 30 Laying and fixing of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size on wall surface/existing cable tray as required. 31 Upto 35 sq. mm (clamped with 1mm thick saddle) 32 Supply and fixing of Loop in loop out Junction box made out of SMC/powder coated GI with minimum size of 250mm x 200mm x100mm (inner) with hinged door fitted with 6A SP MCB, 16A, 8 way Connector, din bar etc to be mounted on existing street light pole including accessories such as clamps/nuts bolts etc. as required as per actual site requirements 33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 34 4C x 10 Sq.mm (25mm) 35 Supplying and retrofitting of following components in the existing LT panel including dismantling the existing switchgears/components, installation of the new switchgears/components, modification/replacement of existing aluminium busbar to suit the capacity of switchgears (if reqd), interconnection with controlwirings etc., complete as per the direction of the Engineer-In-charge as required 36 320A, 50kA,TM release, Four Pole MCCB along with Rotary handle and spreader terminals. 37 125A, 36kA,Micro processor based, Four Pole MCCB along with Rotary handle and spreader terminals. 38 Digital Multifunction meter with RS485 porti/c required control wiring 39 Auxillary Alarm & Trip Contacts suitable for 125A MCCB for SCADA integration 40 Mechanical Interlocking arrangement (3 lock and 2 Key) for incomers and buscouplers 41 Supplying and fixing 3P+N ; Type 1+2 Surge Protection Device (SPD) for three phase AC system 440 V ; 50 Hz, i/c removable cartridges ,TT and TN-S system with Neutral with Imax : 80/100 kA in the existing LT Panel/MCB DB complete with dinbar for mounting, connections, testing and commissioning etc. as required. 42 SH III : SITC of Water Supply Pumpsets and Water level controllers. 43 Supply, Installation, Testing and Commissioning of Energy Efficient Monoblock pumpset (Motor Efficiency : IE2) suitable for lifting water from UG Sump to OH tank with discharge capacity not less than 5.1 LPS at 38 Mtr Head with CI Impeller, SS Shaft & Mechanical Seal etc. suitable to operate on three phase 415V, 50Hz AC supply i/c connection accessories etc. complete as required (Make Kirloskar Model : KDI-538 EE2 or its equivalent from list of approved makes) 44 Supply, Installation, testing and Commissioning of Openwell Submersible pumpset for lifting water from UG Sump to OH tank with C.I Impeller and SS Shaft with discharge capacity not less than 2.0 LPS at 36 Mtr head suitable to operate on three phase 415V, 50Hz AC supply i/c connection accessories etc. complete as required (Make Kirloskar Model : KOS 335+ or its equivalent from list of approved makes) 45 Supply of Horizontal Multistage Booster pumpset suitable for lifting water from UG Sump to OH tank with discharge capacity not less than 60 LPM at 8 mtr head with CI Impeller and SS Shaft, operating on single phase 230V, 50Hz AC supply suitable for 25mm suction and delivery pipes including accessories for connections etccomplete as required (Make: Kirloskar Model : - Agnes 2-20 or its equivalent) 46 Supply, Installation, testing and Commissioning of Borewell pumpset of 4 dia with with NorylImpeller and SS Shaft with discharge capacity not less than 36 LPM at 250 Mtr Head, IP 68 protection etc suitable to operate on three phase 415V, 50Hz AC supply i/c connection accessories etc. complete as required (Make Kirloskar Model : KS4BN-5050 or its equivalent from list of approved makes) 47 Supply and Installation of Three Phase Digital DOL starter with Water Level Controller suitable for automatic and manual operation of all types of pumpset upto 7.5HP capacity complete with Voltmeter, Ammeter, Start/Stop pushbuttons, indication lamps for water level, protections against High/Low voltage, Signle phasing and overload etc in suitable steel enclosure i/c supply and fixing of level float switches on the existing UG Sump/OHT complete as required 48 Supply and fixing of 3C X 4 Sq.mm PVC insulated copper conductor flat cable suitable for submersible borewell pumpi/c fixing accessories complete as required. 49 Supply of 50 mm(OD) HDPE pipe of PE 100, PN 10 grade suitable for submersible borewell pump conforming to IS 4984:1995 complete as per specifications and as required. 50 Supply, Installation, Testing and Commissioning of Water level controller with auto changeover facility and level indicator suitable to operatetwo nos of three phase pumps upto 7.5 HP capacity (one at a time) in suitable MS enclosure along with required nos of sensors for U/G Sump & OHT, connections etc complete as required. 51 Supply, Installation, Testing and Commissioning of Water level controller with level indicator suitable to operateone no. three phase submersible borewell pump upto 7.5 HP capacity in suitable MS enclosure along with required nos of sensors for UG Sump/OHT, connections etc complete as required. 52 Supply, Installation, Testing and Commissioning of Water level indicator for monitoring the level of water inside UG Sump and Terrace Tank/OHT i/c required nos of sensors suitable for operation on 230V, 50Hz, AC supply etc complete as required. 53 Supply and fixing of 5 pair 0.5 sqmm armoured jelly filled cable suitable for water level indicator/controller for interconnection between UG Sump/OHT/Terrace Tank and Monitoring station. 54 SH IV : Earthing Works 55 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 56 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 57 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 58 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 59 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt,spring, washer excavation and re-filling etc. as required 60 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 61 Providing and fixing 6.0 Sq.mm Insulated Copper Wire (Green) in 20/25mm HDPE pipe below 0.5 mtr below ground including excavation and refilling etc complete for loop earthing i/c connection with copper lugs as required. 62 Repairing of existing earth pit including providing and fixing of CI cover plate, funnel, necessary brick work, plastering & painting the masonary chamber complete as per site requirements 63 Supply and Fixing of Conventional Lightning Arrestor consisting of 1.20 meter long solid copper rod, globe having multiple spikes at the top etc complete as required. 64 SH V : SITC of Split ACs and RO Water Purifiers 65 Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split typeInverter type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 500C (out door ambient temperature). 66 1.5 Tr with 5 star BEE rating 67 2 Tr with 5 star BEE rating 68 Supply and fixing of extra copper refrigerent piping beyond standard length of suitable sizefor 2.0 TR Split Air Conditioners complete with suction / liquid line, control cabling etc including all accessories as per site requirement. 69 Supply and fixing of extra drain piping beyond standard length with PVC medium class pipe of suitable sizefor 1.5 TR Split Air Conditioners etc etc complete as per site requirement. 70 Supply and fixing of Voltage Stabilizer of 4KVA capacity suitable for operation on 230V, 50Hz with working voltage of 170V to 270V, intelligent time delay system, high & low voltage cut-off, built-in thermal overload protection, provision for wall mounting etc complete as required. 71 Dismantling of existing Split AC units along with copper piping, drain pipes etc upto 2TR capacity i/c unloading of refrigerant gas into ODU, transporting the same upto AAI stores/location instructed by Engineer In charge etc complete as required. 72 Installation, Testing and Commissioning ofSplit AC units upto 2TR capacity along with copper piping, drain pipes etc i/c transporting the same from AAI stores, filling/toping up of refrigerant gas etc complete as per the instruction of Engineer In charge complete as required. 73 Supply, Installation, Testing & Commissioning of floor mounted type Cold, Hot & Ambient Water Dispenser with minimum 5 stages of purification with inbuilt RO membrane, sediment, active carbon filters etc with minimum 50 LPH Purification rate, SS storage tanks etcincluding all accessories and suitable for operation on single phase, 230V, 50 Hz, AC power supply complete as required. 74 Supply, Installation, Testing & Commissioning of wall mounted type Portable RO water purifier with minimum 5 stages of purification with inbuilt RO membrane, sediment, active carbon filters etc with minimum 14 LPH Purification rate etcincluding all accessories and suitable for operation on single phase, 230V, 50 Hz, AC power supply complete as required. 75 SH VI : Supply of Shoe Shining Machines and Ladders 76 Supply of fully Automatic shoe shining machine with sole cleaner made of stainless steel body, operating on 230V,50Hz supply, with automatic shut off and all other acccessories (Make : Euronics ESM4 / equivalent) 77 Supply of Aluminium self supporting stool type folding ladder of following height made out of high tensile aluminium Alloy along with Al. Platform (with additional support for workmen upto knee height) fitted with hinge and rubber pads at lower bottom ends with sides made of Al. ‘C’ Shape section of size 65mm x 30mm x 3.5mm thick, steps made of63mm dia Non- Slippery corrugated square Tubing on front and back, All Aluminium Raw Material used shall be Alloy & Temper type confirming to IS-733-1975 with uptodate amendments etc.complete as required with prior approval of Engineer-In-Charge. 78 6 feet 79 8 feet 80 Supply of self supporting Aluminium stool type ladder of following height made of high tensile aluminium Alloy fitted with one tool tray on the top and one platform 3ft. below from the top as working man platform along with hinge and rubber pads at lower bottom ends with Sides made of Al. ‘C’ Shape section of size not less than 65mm x 30mm x 3.5mm thick, Steps made of 63mm wide one piece step edging Non- Slippery square corrugated on front and 25mm wide one step square corrugated non slippery on back, All Aluminium Raw Material used shall be Alloy & Temper type confirming to IS-733-1975 with uptodate amendments etc.complete as required with prior approval of Engineer-In-Charge. 81 10 feet 82 20 feet 83 Supply of Aluminium economical telescopic wheeled tower ladder of following height made out of high tensile aluminium Alloy provided with platform, safety ring, railing, pushing handle, lock, pulley, rope fitted with locking device, Two wheels of size 12” x 2” at front side for easy movement and rubber pads at bottom and upper ends with Side made of Aluminum Channel shape section not less than 75x35x3.5mm, Step made ofAluminum 26mm square corrugated tubing, All Aluminium Raw Material used shall be Alloy & Temper type confirming to IS-733-1975 with uptodate amendments etc.complete as required with prior approval of Engineer-In-Charge. Closed Height : 14 FeetExtended Height : 24/25 Feet. 84 SH VII : Other Miscellaneous Works 85 Supply and fixing ofhigh voltage synthetic insulating mat made of synthetic Elastomer suitable for following ratings confirming to IS 15652:2006 with minimum width of 1 metre. Insulating mat should be flexible, anti skid, fire retardant, water and moisture proof with no adverse effect of acids, alkalies and transformer oil. Insulating mat should be fixed with suitable adhesive/chemibond , resin,water proofing compound and other sealing materials as per specifications. Insulating mats should be ISI marked alongwith CM/L nos at every meter. Insulating mats should beERDA and CPRI tested. 86 2.0mm thick with working voltage upto 3.3 KV, Class A 87 2.5mm thick with working voltage upto 11 KV, Class B 88 Supply and fixing of 2mm electrostatic discharge mat (Anti static) made of rubber or similiar material with both static dissipative layer and conductive layer and the mats should have a resistance of not more than 10^5 ohm along with grounding accesries complete. Theminimum width should be of1 metre. The mat should be flexible, anti skid, fire retardant, water and moisture proof with no adverse effect of acids, alkalies and transformer oil. The mats should be fixed with suitable adhesive/chemibond , resin,water proofing compound and other sealing materials as per specifications. 89 Supply of filter sections of various sizes for Air handling Units with 48/50 mm thick washable synthetic type air pre-filters enclosed in aluminium frame having efficiency 90% down to 10 micron etc complete as required as per approved list of makes. 90 Supplying and fixing of 32mm thickness closed cell elastrometric nitrile rubber of minimum 45Kg/cum density, thermal conductivity of 0.037 W/MK or better at 20 deg C mean temperature, class O insulation applied by suitable adhesive as per specifications and as per required complete in all respect. 91 Supplying of 0.60mm thick aluminium sheet cladding over existing insulated chilled water piping with type 3, grade 1 roofing feltstrip at joints complete as required 92 Supplying, of following butterfly valves(Manual) with CI body SS disc nitrile sheet & O-ring & PN 16 pressure ratingin the existing pipe line including necessary cutting / welding works and minor components such as reducer etc acomplete as required as per specifications. 93 80 mm dia 94 100 mm dia 95 Supply, Installation, testing and commissioning of Dial type pressure gauges with gun metal valves etc. as required. 96 Supply, Installation, testing and commissioning of Digital type thermometers i/c fixing the same in the existing chilled water piping. 97 Supply, Installation, Testing, Commisioning of following sizes of 3 way modulating and control valve (CI body) with linkage set for use as mixing valve in AHUs , with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to existing BMS control systemincluding removal of old valve after draining the water. 98 80 mm dia 99 65 mm dia 100 Supply, Installation, testing and commissioning of Digital type Flow Meter suitable for fixing on 2 dia pipe for measurement of flow of sewage/treated water of Sewage Treatement Plant i/c all accessoires for connections etc complete as required.
Contract Date: Oct 30, 2025 Contract Value : 60.60 Lakh
Boards / Undertakings / PSU No of Bidders 2
26.
Rural Development #8369087 AOC
Tender For Lwm Under Sbm Village Lasurne Tal Indapur Dist Pune (Open Class) 5474485 - SUB WORK 1- COMMUNITY LEACH PIT-UNIT- 22Item No 1-Excavation for foundation in Hard murum including removing the excavated material up to adistance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means (DSR PWD 2021-22 P. No. 115 Sr.No. 725) 2 Item No 2-Excavation for foundation in earth, soil of all types, sand, grave lands of soft murum, including removing the excavated material up to a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 3.00 m.) By Manual Means (DSR PWD 2021-22 Sr.No. 718 P. No. 115) 3 Item No 3- Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/granite/ quartzite/gneiss metal for foundation and bedding including bailing out water,Steel centering, form work, laying/ pumping, compacting, roughening the mif special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Typemixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed s and VSI Grade) (DSR PWD 2021-22 Sr.no. 825 P. No. 131) 4 Item No.4- Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ inplinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. (DSR PWD 2021-22 Sr.no. 887 P. No. 144) 5 Item No 5- Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/gneiss metal for foundation and bedding including bailing out water,Steel centering, form work, laying/ pumping, compacting, roughening the mif special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Typemixer/ concrete Batchmixplant (Pan mixer) etc. complete. With fine aggregate (For Sludge P.C.C 0.1M OF Thickness) (Crushed sand VSI Grade) (DSR PWD 2021-22 Sr.no. 825 P. No. 131) 6 Item No 6- Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ inplinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. (DSR PWD 2021-22 Sr.no. 887 P. No. 144) 7 Item No 7 - Providing internal cement plaster 12mm thick in single coatin cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.(Plaster of one for cement morter in side and out side for the above work) (DSR PWD SR No. 955 P.No. 153) 8 Item No 8- The buffalo ball of Shahabadi floor, which is loose at the bottom in the middle of the silt (market rate) 9 ItemNo 9 - Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite/ quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing orasd irected including steel centering, form work, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give as moothandeven surface or roughening if special finish is to be provided and curingetc.complete. (Excluding reinforcement and structural steel). With fully automatic microprocessor based PLC with SCADA enable dreversible Drum Typemixer/concreteBatch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (DSR PWD 2021-22 Sr.no. 839 P. No. 134) 10 Item No 10 - 1100mm from the chamber to the perimeter. PVC pipe of diameter about 1.5 m, in sludge PVC Pipe 140 mm/ 4kg/cm2 506 Rmt 1518 11 Tee 12 SUB WORK 2- COMMUNITY LEACH PIT-UNIT- 25- Item No 1- Excavation for foundation in Hard murum including removing the excavated material upto adistance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means (DSR PWD 2021-22 P. No. 115 Sr.No. 725) 13 Item No 2-Excavation for foundation in earth, soil of all types, sand, grave lands of soft murum, including removing the excavated material up to a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 3.00 m.) By Manual Means (DSR PWD 2021-22 Sr.No. 718 P. No. 115) 14 Item No 3- Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15cm to 20cm thick including hand packing and compacting etc. complete. (DSRPWD2021-22Sr.No.750P.No.117) 15 Item No 4- Providing soling using Aggregates/ metal 63 mm to 45 mm size trap metal in 75 cm. layer including filling(DSRPWD2021-22Sr.No.752P.No.118) 16 Item No 5- Provinmding Secound class burnt brick masonry with converntional / I.S type brick in cement mortal 1:6 in plints as backing in composite masonry including bailing out water manually, striking, joints, raking out joints and watering etc complete.(DSRPWD2021-22Sr.No.144P.No.887) 17 Item No 6 - Providing ISI standard RCC pipes in standard lengths of following class and diameter suitable for either collar joints or rubber ring joints, including all statutary duties and taxessuch as GST levied by Goi and Gom in all respect, inspection charges, transport to departmental stores/site, unloading and stacking etc. complete as per IS - 458/ 1988 Note - One collar should be supplied with each full length plain ended RCC pipe, cost including inratesbelow. One rubber ring should be supplied with each full length of socketed pipe, cost included in rates below. 900 mm dia NP - 2 (DSR PWD 2021-22 I.No.16 P.No.382) 18 Item No 7- Lowering, laying and jointing in proper grade and alignment R.C.C.pipes withcollar joints in C.M. 1.1proportion or socketed R.C.C. pipes with rubber joints (excluding cost of rubber ring or R.C.C. collar.) including cost of conveyance from stores to site of work, cost of jointing material, labour, etc complete as directed by Engineer- in-charge (For all class of pipes)as per I S- 783- 1985. 900 mm dia NP-2 (DSR PWD I No. 36 P.No.386) 19 Item No 8- Providing and Fixing R.C.C. cover on Round Tank 1000 mm dim, etc complete. As Per Market Rate 20 Item No 9- Provinding And Fixing and supling PVC Pipe 75 mm/ 4kg/cm2 (DSR PWD I No. 185 P.No. 378) 21 Item No 10- Providing flush grooved pointing with cement mortar 1:3 for brick work Including scaffolding and curing etc. complete.(DSR PWD 2021-22 Sr.No. 965 P.No.153) 22 SUB WORK 3.DEWAT PLANT FOR GRAY WATER MANAGEMENT - UNIT 1- Item No 1- Excavation for foundation/ pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, prepring, the bed for foundation and necessry back filling, ramming watering including shoring and strutting etc complete. (Lift upto 1.5 m.) By Mechanical Means (DSR PWD 2021-22 P. No. 115 Sr.No.719) 23 Item No 2- Excavation for foundation in Hard murum and boulders including removing the excavated material up to a distance of 50 metres, beyond the building area and stacking andspreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to3.0 m.) By Mechanical Means (DSR PWD 2021-22 Sr.No.726 P. No. 115) 24 Item No 3- PCC Providing and laying Castinsitu/ Ready Mix cement concrete in M 15oftrap/ granite/ quartzite/ gneissmetal for steps including steel centering, form work, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honey combed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled rever sible Drum Typemixer/ concrete Batch mixp lant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (DSR PWD 2021-22 Sr.No.826 P. No.131) 25 Item No.4- Provinmding Secound class burnt brick masonry with converntional / I.S type brick in cement mortal 1:6 in plints as backing in composite masonry including bailing out water manually, striking, joints, raking out joints and watering etc. complete (DSR PWD2021-22 Sr.No.887 P. No. 144) 26 Item No 5- Providing internal cement plaster 12mm thick in single coat in cementmortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (DSR PWD SR No. 955 P.No. 153) 27 Item No 6- Providing external cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (DSR PWD SR No. 962 P.No. 153) 28 Item No 7- Providing srtuctural steel work in rolled section like joints, channels, angel, tree etc.as per detailed designs and drawingincluding fixing in including fixing in (excluding cost of structure steel Jali ) (DSR PWD SR No. 6 P.No. 4) 29 Tmt FE 500 reinfor cement (DSR PWD SR No. 4 P.No. 4) 30 Primery Setlling section C -Item No 1- Excavation for foundation/ pipe trenches in hard murum including removing theexcavated material upto a distance of 50 M and below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, prepring, the bed for foundation and necessry back filling, ramming watering including shoring and strutting etc complete. (Lift upto 1.5 m.) By Mechanical Means (DSR PWD 2021-22 P. No. 115 Sr.No. 719) 31 Item No 2- Excavation for foundation in Hard murum and boulders including removing the excavated material up to a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary bac kfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means (DSR PWD 2021-22 Sr.No.726 P. No. 115) 32 Item No 3- PCC Providing and laying Castinsitu/ Ready Mix cement concrete in M 15 oftrap/ granite/ quartzite/ gneissmetal for steps including steel centering, form work, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honey combed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled rever sible Drum Typemixer/ concrete Batch mixp lant (Panmixer) etc. complete. With fineaggregate (Crushed sand VSI Grade) (DSR PWD 2021-22 Sr.No.826 P. No. 131) 33 Item No.4- Provinmding Secound class burnt brick masonry with converntional / I.S type brick in cement mortal 1:6 in plints as backing in composite masonry including bailing outwater manually, striking, joints, raking out joints and watering etc complete (DSR PWD 2021-22 Sr.No.887 P. No. 144) 34 Item No 5- Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (DSR PWD SR No. 955 P.No. 153) 35 Item No 6- Providing external cement plaster 12mm thick in single coat in cement mortar1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (DSR PWD SR No. 962 P.No. 153) 36 Item No 7-Providing and laying Cast in situ/ Ready Mix cement concrete M-20 of trap/granite/ quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, coverblocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled rever sible Drum Typemixer/ concrete Batch mixplant (Panmixer) etc.complete.With fine aggregate (Crushed sand VSIGrade) (DSR PWD SR No. 849 P.No. 135) 37 Item No 8- Providing and fixing in position TMT - FE - 500 bar reinforcement of various diametersforR.C.C.pilecaps,footings,foundations, slabs,beamscolumns,canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (DSR PWD SR No. 869 P.No. 139) 38 Item No 9- Provinding And Fixing and supling PVC Pipe 110 mm/ 4kg/cm2 for inlet and Outlet (DSR PWD SR No. 188 P.No. 378) 39 Item No 10- Provinding And Fixing and supling PVC Pipe 75 mm/ 4kg/cm2 for gas (DSR PWD SR No. 185 P.No. 378) 40 Secondary Sec A+B-Item No 1- Excavation for foundation/ pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, prepring, the bed for foundation and necessry back filling, ramming watering including shoring and strutting etc complete. (Lift upto 1.5 m.)By Mechanical Means (DSR PWD 2021-22 P. No. 115 Sr.No. 719) 41 Item No 2- Excavation for foundation in Hard murum and boulders including removing the excavated material up to a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to3.0 m.) By Mechanical Means (DSR PWD 2021-22 Sr.No.726 P. No. 115) 42 Item No 3- PCC Providing and laying Castinsitu/ Ready Mix cement concrete in M 15 oftrap/ granite/ quartzite/ gneissmetal for steps including steel centering, form work, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honey combed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled rever sible Drum Typemixer/ concrete Batch mixp lant (Panmixer) etc. complete. With fineaggregate(Crushed sand VSI Grade) (DSR PWD 2021-22 Sr.No.826 P. No. 131) 43 Item No.4- Providing Secound class burnt brick masonry with converntional / I.S type brick in cement mortal 1:6 in plints as backing in composite masonry including bailing out water manually, striking, joints, raking out joints and watering etc complete (DSR PWD 2021-22 Sr.No.887 P. No. 144) 44 Item No 5- Providing internal cement plaster 12mm thick in single coat in cement mortar1:5 without neeru finish to concrete or bricksurfaces,in all positions includin gscaffolding and curing etc. complete. (DSR PWD SR No. 955 P.No. 153) 45 Item No 6- Providing external cement plaster 12mm thick in single coat in cement mortar1:5 without neeru finish to concrete or brick surfaces,in all positions including scaffolding and curing etc. complete. (DSR PWD SR No. 962 P.No. 153) 46 Item No 7- Providing and laying Cast in situ/ Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, coverblocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled rever sible DrumTypemixer/concreteBatchmixplant (Panmixer) etc.complete.With fineaggregate (Crushedsand VSI Grade) (DSR PWD SR No. 849 P.No. 135) 47 Item No 8- Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pilecaps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (DSR PWD SR No. 869 P.No. 139) 48 Item No 9- Provinding dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 150 mm to 200 mm size trap metal including filling(DSR PWD SR No. 750P.No. 117) 49 Item No 10- Provinding dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 40 mm to 80 mm size trap metal including filling(DSR PWD SR No. 752P.No. 118) 50 Item No 11 -Provindingand Fixing and supling PVC pipe 110 mm / 4 kg / cm 2 for inlet and outlet (DSR PWD SR No. 188P.No. 378) 51 Elbow 110 mm / 4 kg / cm 2 52 Item No 12 -Provindingand Fixing and supling PVC pipe 75 mm / 4 kg / cm 2 for gas pipe (DSR PWD SR No. 185P.No. 378) 53 Planed Bed 1&2 -Item No 1- Excavation for foundation/ pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, prepring, the bed for foundation and necessry back filling, ramming watering including shoring and strutting etc complete. (Lift upto 1.5 m.) By Mechanical Means (DSR PWD 2021-22 P. No. 115 Sr.No. 719) 54 Item No 2- Excavation for foundation in Hard murum and boulders including removing the excavated material up to a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means (DSR PWD 2021-22 Sr.No.726 P. No. 115) 55 Item No 3- PCC Providing and laying Castinsitu/ Ready Mix cement concrete in M15 oftrap/ granite/ quartzite/ gneissmetal for steps including steel centering, form work, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honey combed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled rever sible Drum Typemixer/ concrete Batch mixp lant (Panmixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (DSR PWD 2021-22 Sr.No.826 P. No. 131) 56 Item No.4- Provinmding Secound class burnt brick masonry with converntional / I.S type brick in cement mortal 1:6 in plints as backing in composite masonry including bailing outwater manually, striking, joints, raking out joints and watering etc complete (DSR PWD 2021-22 Sr.No.887 P. No. 144) 57 Item No 5- Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (DSR PWD SR No. 955 P.No. 153) 58 Item No 6- Providing external cement plaster 12mm thick in single coat in cement mortar1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (DSR PWD SR No. 962 P.No. 153) 59 Item No 7- Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 150 mm to 200 mm size trap metal including filling (DSR PWD SR No. 750 P.No. 117) 60 Item No 8- Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 40 mm to 80 mm size trap metal including filling (DSR PWD SR No. 752 P.No. 118) 61 Item No 9- Providing and supply hard murum (DSR PWD SR No. 52 P.No. 384) 62 Item No 10- Plantation 63 Item No 1- Excavation for foundation/ pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, prepring, the bed for foundation and necessry back filling, ramming watering including shoring and strutting etc complete. (Lift upto 1.5 m.) By Mechanical Means (DSR PWD 2021-22 P. No. 115 Sr.No. 719) 64 Item No 2- Excavation for foundation in Hard murum and boulders including removing the excavated material up to a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means (DSR PWD 2021-22 Sr.No.726 P. No. 115) 65 Item No 3- PCC Providing and laying Castinsitu/ Ready Mix cement concrete in M 15 oftrap/ granite/ quartzite/ gneissmetal for steps including steel centering, form work, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honey combed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled rever sible Drum Typemixer/ concrete Batch mixp lant (Panmixer) etc. complete. With fineaggregate (Crushed sand VSI Grade) (DSR PWD 2021-22 Sr.No.826 P. No. 131) 66 Item No.4- Provinmding Secound class burnt brick masonry with converntional / I.S type brick in cement mortal 1:6 in plints as backing in composite masonry including bailing out water manually, striking, joints, raking out joints and watering etc complete (DSR PWD 2021-22 Sr.No.887 P. No. 144) 67 Item No 5- Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (DSR PWD SR No. 955 P.No. 153) 68 Item No 6- Providing external cement plaster 12mm thick in single coat in cement mortar1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (DSR PWD SR No. 962 P.No. 153) 69 Item No.07:- providing supplying MS sheet and angal fabricated board with size . 0.90 Mt.X. 1.20 Mt. with 3.0 Mt. angal legs including fixing in concrete and painting as per Instructions. (lumsum Amt. with local rates) 70 TBF 150KLD 1NO. :Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) - 0.0 to 1.5 m 71 Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) - 1.5 to 3.0 m 72 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259) - 1.5 to 3.0 m 73 Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) - 1.5 to 3.0 m 74 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) 75 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B- 7, Page No. 38 76 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 77 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 78 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 79 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 80 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) -c) Corrosion Resistant Steel (Fe 500) 81 Providing and fixing mild steel grill work for windows/ ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (Bd-U-1/537) 82 Providing structural steel work in rolled stanchions fixed with connecting plates or angle cleats as in main and cross beams, hip and jack rafters, purlins connecting to truss members and like as per detailed designs and drawings or as directed by Engineer-in-charge including cutting, fabricating, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd-C-3/275) 83 Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B .W .G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts , lead and bitumen washers as per drawing etc. complete. (Weight of 5.5 kg/sq.m.). 84 Providing fly ash Brick masonry with conventional / I.S. type bricks in cement mortar 1:6 in superstructure including striking, racking out joints and watering and scaffolding etc. complete. 85 Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 86 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11 / 2:3 including scaffolding and fourteen days curingcomplete. 87 Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 88 Providing and applying colour-wash of approved colour and shade in one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc. complete. 89 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 90 Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete. (Bd-A-9/261) 91 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 92 Transportation as per STATEMENT VI Including loading, unloading and stacking. Earth (4.8 Cum) lead 15 km 93 Providing and erecting chainlink fencing 1.6 M. height with G.I. chainlink of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40x40x6 mm size, includind excavating pits for foundation and embedded in C. C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16 mm dia as hold fast including welding link with angle frame at 30 cm c/c with nut sand bolts and horizontal M.S. Angles at top and bottom of 25x25x5 mm size and vertical M.S. flat 35x5 mm and 25x5 mm horizontal including cross support of 40x40x6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450x450x670 mm including 3 coats of oil painting etc. complete. 94 Fine and Coarse Screen (Manual) of size 1.7 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200 mm straight and 50 mm of 90 degree bend. 95 Grit pump -Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below -1 HP (Up to 9000 LPH) - Supply 96 Raw Sewage Pumps -Supplying Non-clog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below - 2 HP (Up to 12000 LPH) - Supply 97 NaOCl Chlorinator Pump Diaphragm Type / peristaltic type / Solenoid / Max Flow Rate Upto 10LPH Power Source Electric - Phase Single Material PP / PTFE(Teflon) / Voltage 230 Volt / Frequency 50Hz. Mixing Tank of 100 Ltrs capacity 98 Dosing Pump 99 Control Panel - Providing & erecting floor/wall mounted MCCB panel board, with door, suitable for four pole incoming 250A, 2 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs) 100 Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. -> 7.5 HP & Up to 12.5 HP 101 Main power supply cable - Main DP to Control Panel cable, 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable, Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. - 3 core 16 sq mm -Supply 102 Power cables -Aluminium conductor 4 Core, XLPE / PVC insulated & armoured cable, Supplying and erecting, XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner. - 4 Core 6 sq mm, Supply 103 Control Cables - Copper conductor PVC insulated, Unarmoured control cable, Supplying and erecting Un-armoured control cable with ISI mark stranded / solid copper conductor 1.1 kV grade complete erected on wall / panel or in provided trench in an approved manner., 4 core 2.5 sq mm, Supply 104 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH-PL/STP 105 Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 106 Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 1) 10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only.2) One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates below. Working Pressure 6 Kg/Sq.cm, Raw Sewage pump to TBF Distribution, Main header, TBF Distribution,Sprinkler, 63 mm. 107 PVC Specials- 10% 108 TBF Perforated Pipe - 75 mm 109 PVC Specials- 10% 110 Collection Tributory, Main Header, 90 mm. 111 PVC Specials- 10% 112 TBF Disposal, 110 mm 113 PVC Specials- 10% 114 Labour, Plumber 115 Helper 116 Sluice valves - Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete 117 Reflux valves (non-return valves) -Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984) 118 Supplying ofSpecially designed container for holding Bio media including mixture of cocohusk,bacterial culture with special worms per designed quantity including transportation & fixing in position as directed etc. complete. 119 Stone Aggregate-20mm 120 Transportation as per STATEMENT VI Including loading, unloading and stacking. Aggregate 40 mm & below (25 Km) 121 Detailed Process Designing, Technology charges and commissioning of Sewage Treatment Plant (STP)based on Tiger Bio Filter (TBF) technologyas turnkey job
Contract Date: Dec 03, 2025 Contract Value : 52.55 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
27.
Defence #8369068 AOC
Tender For Provision Of Klp At Samba; 1 Schedule A Part-I.Constructions of Administrative Building (G+1) complete all as specified and as shown in drgs. 2 Construction of Car, Bicycle and Scooter shed for Adm Office complete all as specified and as shown in drgs. 3 Construction of Single living Accn for officers (S/S) complete all as specified and as shown on drgs. 4 Construction of Car Garages for Offrs Mess (04 Nos) + Single Offrs (02) and Servant Qtrs passing and open garage with apron for Cars complete all as specified and as shown on drgs. 5 Construction of Offrs Mess (11 to 18) (S/S) complete all as specified and as shown on drgs. 6 Construction of JCO Mess Club (41 to 60) and single living accn (15 Nos) (G+2) & parking complete all as specified and as shown on drgs. 7 Construction of Single Living Accn for 79 ORs and 26 HAVs (G+3) along with cook house and dinning hall complete all as specified and shown on drgs. 8 Construction of single living accn for 60 ORs and 12 HAVs (G+3) along with cook house and dinning hall complete all as specified and as shown on drgs. 9 Construction of single living accn for 53 ORs and 16 HAVs (G+3) along with cook house and dinning hall complete all as specified and shown on drgs. 10 Construction of scooter shed for single living accn ORs/ HAVs (For 60 scooters) complete all as specified and as shown on drgs. 11 Construction of scooter shed for single living accn ORs/ HAVs (For 100 scooters) complete all as specified and as shown on drgs. 12 Construction of Guard house, SAA store, Armour Shop and Armouries (S/S) complete all as specified and as shown on drgs. 13 Construction of Storage Accn (S/S) complete all as specified and as shown on drgs. 14 Construction of Instruction room & Instruction store/shed (G+1) complete all as specified and as shown on drgs. 15 Construction of OR’s Institute (S/S) complete all as specified and as shown on drgs. 16 Construction of Station Store (S/S) complete all as specified and as shown on drgs. 17 Construction of Drying and Ironing room & mechanical laundary (S/S) complete all as specified and as shown on drgs. 18 Construction of Religious Institute hall complete all as specified and as shown on drgs. 19 Construction of URC + Family Welfare Centre (G+1) complete all as specified and as shown on drgs. 20 Construction of Guard Room complete all as specified and as shown on drgs. 21 Construction of Elevated Sentry Post with toilet complete all as specified and as shown on drgs. 22 Construction of Incinerator complete all as specified and as shown on drgs. 23 Construction of Fire point complete all as specified and as shown on drgs. 24 Construction of Alarm post 04 (Nos) and Flag mast complete all as specified and as shown on drgs. 25 Construction of Garbage and Refuse Bin complete all as specified and shown on drgs. 26 Lumpsum price worked out by the contractor for Earth work, Site Clearance and Site development works as listed in Schedule A Part-II. 27 Lumpsum price worked out by the contractor for Internal Water Supply works as listed in Schedule A Part-III. 28 Lumpsum price worked out by the contractor for Internal Electrification works as listed in Schedule A Part-IV. 29 Lumpsum price worked out by the contractor for Protective works as listed in Schedule A Part-V. 30 Lumpsum price worked out by the contractor for Road, Path and culvert worksas listed in Schedule A Part-VI. 31 Lumpsum price worked out by the contractor for Sewage Disposal works as listed in Schedule A Part-VII. 32 Lumpsum price worked out by the contractor for PCC Hardstanding works as listed in Schedule A Part-VIII. 33 Lumpsum price worked out by the contractor for Area Drainage works as listed in Schedule A Part-IX. 34 Lumpsum price worked out by the contractor for External Water Supply works as listed in Schedule A Part-X. 35 Lumpsum price worked out by the contractor for External Electrification works as listed in Schedule A Part-XI. 36 Lumpsum price worked out by the contractor for Hot water Supply works as listed in Schedule A Part-XII. 37 Lumpsum price worked out by the contractor for Security Fencing and Steel gate works as listed in Schedule A Part-XIII. 38 Lumpsum price worked out by the contractor for Demolition and Dismantling works as listed in Schedule A Part-XIV. 39 EARTH WORK, SITE CLEARANCE & SITE DEVELOPMENT WORKSEarthwork in excavation in trenches or drains in any type of soil by mechanical means (hydraulic excavator)/(not exceeding 1.5m in width and 10 Sqm on plan), exceeding 1.5m upto 3.00m in depth, including dressing of sides and ramming of bottoms, left upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50metre complete all as specified and directed. 40 Earthwork in excavation in trenches or drains in any type of soil by mechanical means (hydraulic excavator)/(not exceeding 1.5m in width and 10 Sqm on plan), exceeding 3.00m upto 4.50m in depth, including dressing of sides and ramming of bottoms, left upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50metre complete all as specified and directed. 41 Earthwork in rough excavation in any type of soil by mechanical means (hydraulic excavator) not exceeding 1.5m deep and getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m complete all as specified and directed by Engineer-in-Charge. 42 Internal Water SupplyGalvanized iron steel water tubing, 15mm bore, medium grade, with all fittings (ISI Marked), fixed complete to walls, ceiling and laid in floors concealed type including cutting chases for concealed water tubing and making good in CM (1:3) complete all as specified and as directed by Engineer-in-Charge. 43 Galvanized iron steel water tubing, 20mm bore, medium grade, with all fittings (ISI Marked), fixed complete to wall, ceiling and laid in floors concealed type including cutting chases for concealed water tubing and making good in CM (1:3) complete all as specified and as directed by Engineer-in-Charge. 44 Internal Electrification Works LED Tube Light 20 Watt luminaire basic all purpose surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver complete including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to LED fitting connector and necessary mounting clamp on two sets complete all as specified & directed by Engineer-in-Charge. 45 Round shape 06 watt 220 volts AC recessed/ ceiling mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed by Engineer-in-Charge. 46 Round shape 15 watt 220 volts AC recessed/ ceiling mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed by Engineer-in-Charge. 47 Round shape 12 watt 220 volts AC recessed/ ceiling mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed by Engineer-in-Charge. 48 LED Luminiare 600mm x 600mm, 36 Watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamps suitable with roof ceiling connecting up with driver 3 core flexible copper conductor cases of suitable size complete all as specified & directed by Engineer-in-Charge. 49 LED street light fitting 20 watt, 230 volts, AC outdoor type with high pressure die cast aluminium housing and heat resistance complete with driver, lamp bracket with impact corrosion resistant including thermal management multiple optics complete with IP 65/66 protection complete including suitable size GI bracket with medium grade pipe required nut, bolt, washers to fixed on existing wall complete all as specified & directed by Engineer-in-Charge. 50 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole phase and neutral MCB 20 Amps complete for AC point complete all as specified & directed by Engineer-in-Charge. 51 Ceiling fans complete with blades, down rods, including electronic regulator and accessories, 230 V, 1200mm steep, Min air delivery, 210 CFM with service value 6.00 BEE point five star rated with brushless direct current mortor (BLDC) complete all as specified & directed by Engineer-in-Charge. 52 Exhaust fan, steel body AC Single phase, 230 volt of size 300mm sweep with blades and frame and louvers complete all as specified & directed by Engineer-in-Charge.Note: The contractor should make necessary hole for fixing exhaust fan and fix the exhaust fan with suitable size of fastener and bolts in wall deemed to be included in the quoted rate. 53 MCCB 3 pole, 440 volt, 25-100 Amps rating capacity of breaking capacity 16 kA, fixed type complete all as specified and directed by Engineer-in-Charge. 54 MCCB 3 pole, 440 volt, 160 Amps rating capacity of breaking capacity 16 kA, fixed type complete all as specified and directed by Engr-in-Charge. 55 Sheet metal enclosures distribution boards, double door VTPN, 415 volts 6 way suitable for fixing MCCB as incomer and MCBs as outgoing (One incoming three phase & twelve outgoings single phase) for MCCB & MCBs comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed.Notes:(i) The DB shall be VTPN series.(ii) The DB shall be flush fixed and making disturbed surface matching with existing specifications shall be part of work no extra cost.(iii) Connection of the MCCBs and MCBs with cable shall be made through appropriate size pin/ bottle type copper thimble properly crimped.(iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size.(v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly.(vi) MCCB and MCB rate considered in separate item of schedule. 56 Sheet metal enclosures distribution boards, double door VTPN, 415 volts 4 way suitable for fixing MCCB as incomer and MCBs as outgoing (One incoming three phase & twelve outgoings single phase) for MCCB & MCBs comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed.Notes:(i) The DB shall be VTPN series.(ii) The DB shall be flush fixed and making disturbed surface matching with existing specifications shall be part of work no extra cost.(iii) Connection of the MCCBs and MCBs with cable shall be made through appropriate size pin/ bottle type copper thimble properly crimped.(iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size.(v) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly.(vi) MCCB and MCB rate considered in separate item of schedule. 57 Earthing with galvanized steel earth plate electrode 600 x 600 x 6.0mm thick buried directly in ground pit not less than 2.25mtr deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to 4.00mm dia GI wire & PVC insulated solid copper conductor of size 4mm by means of nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover, 20mm dia (MG) GI watering pipe with funeel wire mesh and protection pipe of GI of 15mm dia up to 7.5mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of strata complete all as shown in electrical plate No 3 of MES SSR Part-I as specified. GI wire & 4mm dia solid conductor PVC insulated for continuity earth wire from test point to main distribution board and all as specified and as directed. Note :- Rate for achieving required depth by compressor machine if required is deemed to be included on the quoted unit rate. 58 Road, Path & CulvertsReflective type cat eye having colour red/yellow to a side, casted aluminium allow of size 1100x100x20mm with built in steam of suitable length for fixing with protected in side as approved by complete all as specified and directed Engineer-in-Charge, Cat Part no OS-786. 59 Stainless steel round delineator having reflector type red/ yellow colour in plastic body protected in side poly carbonated sheet, protected with powder coated wire mesh cage system mounted as approved by complete all as specified and directed Engineer-in-Charge, cat part no. OS-802. 60 Information board with ACP sheet retro reflective writing one side size 600x900 mm. Made around of reflective intensive tape dully fixed on angle iron frame 40x4x4 mm frame with aluminium sheet both side 2mm thick as requiredwith PCC 1:4:8 for post and PCC directed by complete all as specified and directed Engineer-in-Charge. 61 Sewage DisposalDWCPE (SN8) 180 (OD)/ 163(D)mm diameterpipes integral socket and necessary fittings, laid in trenches including jointed and overlapping of pipes complete all as specified and as directed by Engineer-in-Charge. 62 DWCPE (SN8) 200 (OD)/ 175(D)mm diameterpipes integral socket and necessary fittings, laid in trenches including jointed and overlapping of pipes complete all as specified and as directed by Engineer-in-Charge. 63 LLDPE septic tank made of polyethylene, single moulded, and conventional type. The unique size and three chamber design of any make from syntax/ united/ supreme. It should have atleast two manholes provided for convenience and salt resistance and made by non degradable plastic capacity for 10 users, thickness min 10mm, size of manholes 550mm dia. Dia of inlet and outlet pipe should be 110mm and dia of vent pipe is 50mmcomplete all as specified and as directed by Engineer-in-Charge. 64 RCC septic tank for 50 users with effective depth of 1.5 metre and overall depth of 3metre, complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 65 RCC septic tank for 100 users with effective depth of 1.5 metre and overall depth of 3metre, complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 66 RCC septic tank for 150 users with effective depth of 1.5 metre and overall depth of 3metre, complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 67 RCC septic tank for 200 users with effective depth of 1.5 metre and overall depth of 3metre, complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 68 Construction of soakage well, (brick construction) size 1.8mtr dia 3.0m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 69 Construction of soakage well, (brick construction) size 3.0mtr dia 4.5m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 70 Construction of soakage well, (brick construction) size 3.0mtr dia 6.0m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 71 Construction of soakage well, (brick construction) size 3.6mtr dia 6.0m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 72 Construction of soakage well, (brick construction) size 2.4mtr dia 4.5m deep, below inlet pipe level (depth from inlet pipe to ground level to 45cm) complete all as specified and shown on drgs and as directed by Engineer-in-Charge. 73 CHIMNEYSupply and fixelectric stainless steel commercial chimney of capacity 1250CFM/hr of size 6 feet hood and size 2 feet length (30 inch in length each with BLDC motor of suitable size ) with LED light , purfreted filter complete along with fixing with help of angle bold complete all as specified by manufarcturer and making hole for flexible exhaust pipe through cutting of wall and making outlet at outside the kitchen area complete all as specified. 74 Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5mtr below normal ground level connected to GI galvanized iron strip of size 32×6mm and 40mm dia bore light grade GI protection pipe for earth strip and GI watering pipe 20 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009 complete all as specified and directed. (Transformer -04 Nos + VCB-02 Nos + 7 NOs Panel -14 Nos + Compacted Sub-station-02 Nos) 75 Supply, laying, jointing and testing LT cable 1100 volts grade of cross sectional area400 sqmm 3.5 core as per IS-7098 (Part-I) 1988, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required , laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and as directed.Note:- (i) MS clamps with nuts, bolts washer etc required for fixing on wall rate deemed to be included on the quoted rate. (ii)Cable path indicators shall be provided at distance of every 100 metre s and at cable joints and turning of all cables except for 2 core cables size and voltage written on it. The CI path indicator shall be fixed on MS angle iron. The cable path indicators shall be erected at the time of refilling the trenches and the cable path indicator shall be painted as under. -(i) For LT cables - “BLUE”. (iii) Earth work like excavation, Returning re filling, removal, sand cushioning, cable covers, GI pipe measured and paid separately under relevant item of schedule. 76 All as per Item No 75 above but size of cable 300 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 77 All as per Item No 75 above but size of cable 240 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 78 All as per Item No 75 above but size of cable 150 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 79 All as per Item No 75 above but size of cable 70 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 80 All as per Item No 75 above but size of cable 50 Sqmm 3.5 core complete all as specified and as directed by Engineer-in-Charge. 81 All as per Item No 75 above but size of cable 25 Sqmm 4.0 core complete all as specified and as directed by Engineer-in-Charge. 82 All as per Item No 75 above but size of cable 16 Sqmm 4.0 core complete all as specified and as directed by Engineer-in-Charge. 83 All as per Item No 75 above but size of cable 16 Sqmm 2.0 core complete all as specified and as directed by Engineer-in-Charge. 84 All as per Item No 75 above but size of cable 10 Sqmm 2.0 core complete all as specified and as directed by Engineer-in-Charge. 85 All as per Item No 75 above but size of cable 10 Sqmm 4.0 core complete all as specified and as directed by Engineer-in-Charge. 86 Structural steel work as the cross arms, bracing supports, clamps, back plate fabricated from structural steel sections including nut bolts, washers, welding, bending hot or cold drilling holes for both in any shape or size as indicated or directed by Engineer-In-Charge and inclusive of one primer coat one under coat and one finishing coat of synthetic enamelled paint including preparation of surfaces. 87 Supply, install, testing and commissioning of 11 KV, 350 MVA, 630 A rating, 18.4 KA (Short time current rating), 1 Way, indoor VCB with EnclosureMotorized type as per Specification with 1 incoming and 1 outgoing VCB complete all as specified and directed by Engineer-in-Charge.Location: Sub station No 02 GE Samba office inside campus1. Each Incomer feeder with Switch consists of: (a) Motorized 630 A, 350 MVA VCB enclosure with built in earth switch with full making capacity-01 Nos(b) Mechanical position indicator. Switch ON/ OFF/ Earthed-01 No(c) Live cable indication-01 No(d) Cable compartment cover interlocked with earth switch-01 No.(e) Cable termination bushing-01 Nos for 3 Core 95 Sqmm HT cable.(f) 11 KV XLPE Cable termination Kit with boot-01 Set(g) NO/NC contact for -01 Set(i)Isolator ON/OFF (ii) Earth Switch ON/OFF (iii) Fault indicator Operated.(h) Command Output for -01 Set(i) Isolator close(ii) Isolator Open(iii) FPI Reset(j) Anti Pumping Relay -01 Nos 88 (k) Digital MFM (EM646 or equvt) -01 Nos. (l) Indications: (i) ON/OFF/Trip Indication Light -01 Sets. (ii) Spring Charge Healthy indication-01 Nos. (iii) Trip Circuit Healthy Indication-01 Nos. (iv) Test / Service Postion Indicator-01 Set. (n) Breaker Control Switch-01 No.(o) L/R Switch-01 Nos(q) 3 pin Plug and socket-01 Nos. (r) Toggle switch-01 Nos. (s) Hooter-01 Nos.(t) Annuniciator 8 Watt-01 Nos. (u) 24 V DC Power Pack, 17 Ah-01 Nos. (v) Door switch-01 Nos. (w) Space Heater with thermostat-01 Nos. (x) Control MCB set comprisiong ofSPN MCBs as per relays and meters-01 Set . (y) Cable termination bushings suitable for 2 Nos 3 C x 95 Sq mm XLPE cable -01 Sets each one for one Incoming VCB(z) 11 KV Screened cable termination kit with boots-01 sets each one for one Incoming VCB 89 (a) Gas pressure indicator with auxillary contacts.(b) 1 No. Handle per RMU(c) Battery & Battery Charger3. Civil workThe platform for placing VCB as per manufacturers technical drawing and made suitable PCC ducting for laying cable and fill with reuired level fine sand on treches all as specified and directed by Engr-in-Charge. common items: (i) Battery & Battery charger.(ii)Warning board marking as HT 11 KV Danger with skull and writing with English, Hindi, local language.(iii)Before quoting rate the contractor must visit siteand to connect the new VCB to existing VCB the required size of bus bar and connected items deemed to be included on the quoted rate. The existing Incoming VCB of make CG in sub station no 2. 90 Supply, installation, testing & commissioning of package type/ unitised 11kV / 433 V Outdoor sub-station, 630 kVA made from G.I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specificationsfor the rating, Internal Arc of 21 or 18.4 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/ outgoing cables/ earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation. RMU, LT panel switchgear and CSS enclosure shall be of same make to ensure life cycle optimization.Note : CSS shall be from OEMs only. Licensed System Integrators are not allowed to supply . 91 HT SWITCHGEAR11kV 630Amps 18.4 KA/3 secNon-Extensible Ring Main Unit Compact switchgear consisting of2 Nos. fixed manual operated Load Break Switch and1 Nos. fixed manual operatedBreaker Module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. Operating sequence of breaker must be O-0.3Sec-CO-3 Mins-CO and suitable for 10000 mechanical operations. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.(a) Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil.(b ) Capacitive voltage indication fixed type system with LED(c ) SF6 Gas pressure indicator.(d) Padlocking facility.(e ) Protection CT shall be minimum 60/1A ,2.5VA ,5P10. - 3 nos.(f) Operating Sequence of breakershall be O-0.3sec-CO-3MIN-CO(g) LBS module will have FPI.(h) All modules of the RMU shall be suitable for cable termination of 3C x 95 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 92 TRANSFORMER630 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-3transformerwith corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1745W and Max Losses @ 100% Load 4850 W and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (Make of transformer:- As per CSS Manufacturer approved Make- One No. Winding Temperature Indicator with Alarm and trip ContactLT PANELLVS PANEL 1000 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminium as 1 A/sq.mm. ; LT panel made up of 2 mm thick CRCA sheet 93 INCOMER FROM TRANSFORMEROne number 1000Amps 4 pole 415V MDO ACB (incoming) with moulded case construction having breaking capacity 50KA with Ics = Icu = Icw (1 sec) = 50KA with microprocessor release for over current, earth fault & short circuit protections. The ACB should be of command approved make.One number Intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz, kVARh, Vah, VARh, MD, and RS 485 portetc. with 3 Nos. resin cast CTs of 400/1A class 0.5 accuracy and 5 VA burden - 1 No.One set of Phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as required.Outgoings:(a) MCCB 4 pole, 400A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 02Nos (b) MCCB 4 pole, 250 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No 94 (c) MCCB 4 pole, 200 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 02 Nos (d) MCCB 4 pole, 160 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No (e) MCCB 4 pole, 100A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 02 Nos(f) MCB SPN 40 aMPS, - 02 Nos (for out going).One set of Phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as required.All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work. 95 OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment. The supply of all above equipments, erection, testing and commissioning and suitable size of manufacture recommended plinth for erectoin of CSS rate included on the quoted rate. The contractor should submit the technical drawing of Compact sub station including Transformer, HT /LT breakersand foundation drawing recommended by the manufacturer for approval of this office. The rate included for the PDI test and the first fill of Transformer oil. The contractor should submit all Test report of Transforemr, LT /HT panels before made payment by department. 96 Solar two in one (semi integrated)LED street lights 36Watt with aluminium housing, weather proof IP 66>125 lm/watt efficacy, 75Wp solar module of solar PV panel poly crystalline, inbuilt 36 Ah solarbattery 12.8 V, LiFEPo4battery with BMS, dimming and charging controller of MPPT Integral charge controller of electronic efficiency>90% (Inbuilt into the street light), PIR sensor, 5500-6500 K, short circuit protection, reverse polarity protection and prevent reverse discharge battery, overcharge/deep charge protection all as specified and directed by Engineer-in-Charge. Notes: (i)The minimum 80 mm dia GI pole of 08 Mtrs long along with clamp, nut, bolt, washer to fix solar light rate deemed to be included on quoted rate.(ii) The earth work of excavation, PCC, Returning filling, Removal for install pole measured and paid separately.(iii) The ON/OFF control switch placed above 2.5 mtrs height of ground level. 97 Supply, laying, jointing and testing of HT cable 11000 volts grade and working voltage 24 KV of cross sectional area 95 Sqmm 3 Core as per IS-7098 (Part- I) 1988, ISI marked and make, RM of cable, CML No are imposed with insulating cover as well as printed on insulation, of XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles for incoming and outgoing cables complete all as specified and directed by Engineer-in-Charge. 98 Note:(i) Earth work like excavation, Returning re filling, removal, sand cushioning, cable covers, GI pipe measured and paid separately under relevant item of schedule.(ii)Cable path indicators shall be provided at distance of every 100 metres and at cable joints and turning of all cables except for 2 core cables size and voltage written on it. The CI path indicator shall be fixed on MS angle iron. The cable path indicators shall be erected at the time of refilling the trenches and the cable path indicator shall be painted as under.(i) For HT 11 KV cables - “BROWN” 99 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 4 JCOs Mess)((i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate.No extra payment will be made. 100 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 100 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 No (for Incoming).(b) MCCB 4 pole, 40 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(c ) MCCB 4 pole, 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 02 Nos (for out going).(d)MCB SPN 6 to 32 amps 240 Volt- 01 Nos (outgoing)(e) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No .(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 101 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No SM Barrick)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cmsNote:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate ), deemed to be included in the item rate. No extra payment will be made. 102 (Note: This panel shall be a front operated with cable entry from the bottom. The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 400 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 36 KA-01 No (for Incoming).(b) MCCB 3 pole, 63A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 06 Nos (for out going).(c ) MCCB 3 pole, 25A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(d) MCB SPN 10-32 Amps, 10 KA , 240 v-01 No (for Outgoing)(e) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No.(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 103 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No Laundary )(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 104 (Note: This panel shall be a front operated with cable entry from the bottom. The fault with standing capacity shall be 25 KA. Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 200 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for Incoming) .(b) MCCB 3 pole, 160 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 1 No (for out going).(c ) MCCB 3 pole,25, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 03 Nos (for out going).(d)MCB SPN 6 to 32 amps 240 Volt- 06 Nos (outgoing)(e) Digital Ammeter 0 to 500 Amp with selector switch & suitable range of CTs - 01 No.(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 105 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 5 near Offr Mess)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 106 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 250 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 36 KA - 01 Nos (for Incoming) .(b) MCCB 3 pole 125 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(c) MCCB 3 pole 100 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 01 No (for out going).(d) MCCB 3 pole 63 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA -1 No (for out going).(e) MCCB 3 pole 32 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA -1 No (for out going).(f) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 04 Nos (for out going).(g)MCB SPN 6 to 32 amps 240 Volt - 12 Nos (out going)(h) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(i) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(j) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 107 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 6 near URC, FWC)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 108 (Note: This panel shall be a front operated with cable entry from the bottom. The fault with standing capacity shall be 25 KA. Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 160 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 Nos (for Incoming) .(b) MCCB 3 pole 40 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA -2 Nos (for out going).(c) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 03 No (for out going).(d)MCB SPN 6 to 32 amps 240 Volt - 11 Nos (out going)(e) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(f) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(g) LED Phase indicating lamp (Set of three) - 03 Nos (RYB) 109 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 7 MT Area)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cmsNote:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 110 (Note: This panel shall be a front operated with cable entry from the bottom. The fault with standing capacity shall be 25 KA. Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 100 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 Nos (for Incoming).(b) MCCB 3 pole 25 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 03 Nos (for out going).(c)MCB SPN 6 to 32 amps 240 Volt - 05 Nos (out going)(d) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(e) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(f) LED Phase indicating lamp (Set of three) - 03 Nos (RYB) 111 Supply ,Installation ,testing & commisioning of totally enclosedfeeder piller outdoor type(IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powdercoated double door type(independent cabin including locking arrangementforeach MCCBs and provide space spreader for all MCCBs, bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt50 Hz AC, supply internally wired with copper conductor , TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault lavel at 415 Volts having legs 45 cms made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cms .Brick masonary plateform should be 60 cms abovethe Ground Level.Comprising the following : (LT Panel No 8 LIFT)(i) The panel shall be front operated with cable entry from the bottem with cable glands. (ii) Fabrication of feeder piller box to be approved by CPRI width of the panel not less than 60cms Note:- Cost for construction of plateform for panel of brick masonary work in CM 1:6 with foundationPCC 1:4:8 type D-2including plaster work ,PCC copping 1:2:4 (40 mm thick stone aggerate ) ,deemed to be included in the item rate .No extra payment will be made. 112 (Note: This panel shall be a front operated with cable entry from the bottom .The fault with standing capacity shall be 25 KA .Earth bus shall be part of the main feeder pillar.)(a) MCCB 4 pole, 400 A, 415 volt 50HZwith thermal setting 70% to 100% and rupturing capacity not less than 25 KA - 01 Nos (for Incoming) .(b) MCCB 4 pole 100 A, 415 volt 50HZ with thermal setting 70% to 100% and rupturing capacity not less than 16 KA - 07 Nos (for out going).(c)MCB SPN 6 to 32 amps 240 Volt - 05 Nos (out going)(h) Digital Ammeter 0 to 200 Amp with selector switch & suitable range of CTs - 01 No.(d) Digital Voltmeter 0 to 500 V with selector switch - 01 No.(e) LED Phase indicating lamp (Set of three)- 03 Nos (RYB) 113 Security FencingConcertina coil 600mm dia, stretched to 6 RM, having 50 Nos spiral turns per 6 metrelength, spring co wire (2.59 mm thick ) of high tensile strength of 1620 N /sqm with tape (0.52 mm thick) Hot & galvanized upto 20 microns, weight of each coil 8.50 kg and fixing the same on Y-shaped angle iron with6 horizontal RBT (reinforced Barded Tape) wire, stud tied with GI clips to retain horizontal, clips shall be @ 5 Nos per 2 spiral turns approximate 125 clips per coil including necessary bolts complete all as specified and as directed by Engineer-in-Charge. 114 Construction steel gate of 5.5m wide and 3 m high with wicket gate 1.2 m wide and 3m high including RCC columns, painting steel surfaces in two coats over one coat of primer and two coat of colour wash over a coat of white wash to RCC column including excavation and earth work in any type of soil, RCC for columns, Reinforcement for columns and framed work, MS sheet for steel gate, complete all as specified and as directed by Engineer-in-Charge. 115 External Water supplyCutting the existing DI/CI water supply pipe line 150mm dia and inserting Tee 150x150x150 mm complete all as specified and as directed by Engineer-in-Charge. 116 Supply and lay pipe ductile Iron (Conforming to IS-8329-2000) with spigot and socket ends of bore 150 mm(6) diaspecial Class “K-9” including jointing material/joints laid in trenches complete all as specified and as directed by Engineer-in-Charge. 117 Construction of brick masonry valve chamber of internal dimensions 900 x 900 x 900 mm, bottom floor of the pit shall be constructed in PCC (1:3:6) 15 cm thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 mm thick. The top cover of the pit shall be made out of MS sheet min 3 mm thick with angle iron frame made out of MS angle 40 mm x 40 mm x 6 mm with 02 nossteel hinges and locking arrangements duly painted with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge. 118 Supply and fix Air release valve 50 mm dia with two air outlets and fixing up in DI water supplymains complete all as specified and as directed by Engineer-in-Charge. 119 LIFTDesign supply, installation, testing & commissioning of 8 passenger lift, having 0.75 meter/second car speed, operate with Permanent Magnet Synchronous motor suitable for 3- Ph, 415V, 50Hz electric power supply, conforming to IS-14665, suitable to serve G + 03 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos., one each in car, machine room & near ground floor landing door) complete all as specified and directed.The lift shall conform to the following technical specification.[i)Type of Lift: 8 Passenger[ii) Load Capacity: 544kg[iii)Speed 0.75 meter/second[iv]Type of Drive: AC Variable Voltage & Variable Frequency[v] Type of Machine: Gearless with PMSM (Permanent Magnet Synchronous Motor)[vi]Car Size: Not less than 1.43 m² 120 [vii]Car and Landing Door at all floors: Automatic center opening with VVVF door drive, opening size not less than 800X2000mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304)[viii] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N304) having stainless false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light complete internal ventilation system provided with concealed arial/ cross flow fan with auto cut-off system and stainless steel grill/ wire mesh for protection.[ix] Provision of standard thicknes stainless steel hand-rail 40mm diameter all around inside the car cabin.[x] Terminal Buffers: Metal special spring/PU/Oil buffers as per manufacturer specifications. The buffing stroke should not be less than 200mm.[xi] Door Opening (Inside): Protected by centre opening stainless steel doors with hairline finish doors with clear opening of 800X2000mm[xii] Car & Counter Weight Guide: Guide rails of MS T section as per OEM design; counter weight shall be as recommended by OEM[xiii] Flooring: 5mm thick Aluminium chequred plate / as per OEM design 121 [xiv] Signals:[a] Combined luminous hall buttonswith LED/ LCD /VFD hall position indicators at all floors[b] LED/LCD/VFD for car position indicator of stainless steel[c] One No. of car opening panel with luminous buttons in car (stainless steel)[d] Car direction indicator in car & landing[e] Battery operated alarm bell & emergency light (rechargable) along with suitable maintenance free battery (This system should be separate from ARD batteries.)[f]Overload warning feature in car cabin (display and announcing type both)[g] One firemans switch to be installed at ground floor near landing door[h] All signal fixture & car operating panel on hairline stainless steel face plate with hairline finish.[i] Infra red door sensor safety edge of door for entire height.[j] Built in announcing system without handset 2 Nos., one for lift car & ground floor landing door and one anouncing system with handset in machine room.[k] The interior of the car should be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance/ exit door is open or closed. 122 [xv] Safety Device:[a] Automatic rescue device (ARD)/automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regerertive drive.[b] The ARD actuation time should be less than one second after failure of power supply and when ARD is operative the car should stop at the nearest floor and then open.[xvi] Operation: Simplex, full collective automatic operation with and without attendant.[xvii] Machine room: Located above the hoist way.Details as per building drawing[xviii] Civil work: Necessary Civil work viz. making good disturbed surfaces, modification to landing space to suit to car size, necessary foundation to machine etc.[xix] One number of wall mounted type telephone instrument of make installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room.[xx] The lift motor covered with suitable size of OEM recommended steel cover. 123 [xxi] To provide over speed Governor and its connected safety tongs as per OEM recommendation for control over speed if exceed 20% on assigned speed.[xxii] To provide fire sensor mode sensors and its assembly to lift during safety of fire.[xxiii] To provide overload sensors if load exceeds permissible limits the lift will not move and the over loads show in COP & LOP.[xxiv] The lift brakes should be designed as dual safety brakes.[xxv] The contractor should laision with state Lift inspector for making lift license and the lift inspector testing and visiting charges are deemed to be included on the quoted rate. The license issued by the state lift inspector should be submit the department and photocopy of license pasted on inside cabin without inspection of State Lift inspector the payemnt should not be made to contractor for all lift connected items.Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor 124 Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5mtr below normal ground level connected to galvanized GI earth galvanised iron strip of size 32×6mm and 40mm dia bore light grade GI protection pipe for earth strip and GI watering pipe 20 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR partI of 2009 complete all as specified and directed. 125 GI strip 20 x 3.0 mm with procelain insulators and fixing screws etc from earth pit to lift roomcomplete all as specified and as directed by Engineer-in-Charge. 126 Test point terminal block madeof gun metal or phosphorusbronze size 75x75x25mmdrilled and screwed including3 nos. 8mm dia 25mm longhex. head screwto connect earth stip and earthi stip mount suitable size of insulatorscomplete all as specified and as directed by Engineer-in-Charge. 127 Summer AppliancesSupply, installation testing and commissioning of heavy Duty Package Air Cooling Units, Top/ Down (Universal) Discharge with following features 4 inch thick imported high efficiency cellulose pads on 4 sides, optimized 3 Phase motor and fan to deliver the powerful air flow, water pump in wet section, cool flow dispenser for better coooling, auto connection of water tank to quick fill, water connection with ball valve, drain and overflow connection, weather resistat engineering plastic body with dust filter comprising of following capacity complete.Note : (i) The contractor should provide ducting passing drawing and cooling unit technical drawing to the department for approval.(ii) The package air cooler installed at G + 3 building and required T & P for positioning the 24 Nos of plant in top of the roof in six nos of G+3 building in various location in Samba Military Station deemed to be included on the quoted rate. 128 21000 CFM 129 13000 CFM 130 11000 CFM 131 9000 CFM 132 Supply, connection, testing and commissioning of flexible connection of material canvascomplete all as specified and as directed by Engineer-in-Charge. 133 Supply, installation, testing and commissioning of Factory Fabricated GI Sheet Spiral Oval/ Round Ducting with required Hardware Sheet 22 Gaugecomplete all as specified and as directed by Engineer-in-Charge. 134 Supply, installation, Testing and commissioningof Factory Fabricated GI Sheet Spiral Oval/Round Ducting with required HardwareSheet 24 Gauge complete all as specified and as directed by Engineer-in-Charge. 135 Supply and application of Acoustic treatment of ducts with 15 mm thick open cell, elastomeric nitrile rubber, of 140 Kg/m3 density dust free, fiber free, and CFC free insulation pasted inside the Duct with the help of adhesive complete all as specified and directed by Engineer-in-Charge. 136 Supply, installation, Testing and commissioning of Thermal Ductinsulation with 6MM Thick Aluminum Foil Faced XLPE Pasted on Duct with Rubber Adhesive complete all as specified and directed by Engineer-in-Charge. 137 Supply, installation, Testing and commissioning of SupplyAir Aluminum powder coated Linear Grill/Diffuserswith M.S. volume controlduct dampercomplete all as specified and as directed by Engineer-in-Charge. 138 Supply, installation, Testing and commissioning of Site Fabricated MS Angle Iron Stand for Ductable Air Cooling Unit with Black Enamel Paint, Including Lifiting & Placing of Air Washers complete all as specified and as directed by Engineer-in-Charge. 139 Supply Installation, Testing and Commissioning of 2.5sqmm x 4 Core Copper Cablingcomplete all as specified and as directed by Engineer-in-Charge. 140 Supply, installation, testing and commissioning of water connection with 2000 Ltrs Water tank PVC moduled & required accessories for evaporating ductable air cooling unitcomplete all as specified and as directed by Engineer-in-Charge. 141 Supply, laying 3 layer PP-R Polypropylene random co polymer concealed pipes of size 32 mm SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability forcold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors connected on water tank to air cooling unit and motorscomplete all as specified and as directed by Engineer-in-Charge. 142 PP-R Gate valves (brass inserted) of size 32 mm dia to connect the PP-R pipecomplete all as specified and as directed by Engineer-in-Charge. 143 Triple pole and earthencolsure with a threepin and earth plug withsocket complete withone triple pole MCB 40 -63 Ampscomplete all as specified and as directed by Engineer-in-Charge. 144 Supply, Installation, commissioning and testing of Refrigerator inverter type direct cool electricdriven (single phase) 240 volts, 50 Hz with inbuild voltage stabilizer of capacity 200 Ltrs BEE 5 star ratedcomplete all as specified and as directed by Engineer-in-Charge. 145 Supply, installation, commissioning and testing of Water cooler electric driven (single phase) having approx storage capacity of 80 Ltrs and nominal cooling capacity of 40 ltrs per hour complete all as specified and as directed by Engineer-in-Charge. 146 Supply, installation, commissioning and testing of Water cooler electric driven (single phase) having approx storage capacity of 120 Ltrs and nominal cooling capacity of 60 ltrs per hour complete all as specified and as directed by Engineer-in-Charge. 147 Supply, installation & commissioningand testing of desert cooler electric driven (single phase) having nominal air flow of capacity 3000 cum /hr with high efficiencyhoneycomb pad water capacity 75 Ltrs PVCbodycomplete all as specified and as directed by Engineer-in-Charge. 148 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA complete all as specified and as directed by Engineer-in-Charge. 149 Supply, Installation & commissioningof Glass top Deep freezer 320 Ltrs capacity having double door single phase complete all as specified and as directed by Engineer-in-Charge. 150 Note: The schedule of credit has been attached in tender in Pdf format as Sch A Part-XV and amount of credit schedule i.e. Rs 2006105.50 shall be deducted from the total amount of BOQ to arrive at the contract sum.
Contract Date: Dec 03, 2025 Contract Value : 48.48 Crore
Statutory Bodies & Commissions/Committees No of Bidders 12
Jammu And Kashmir View Result →
28.
Rural Development #8366663 AOC
Tender For Liquid Waste Management Scheme At Samode Tal Sakri Dist Dhule - Liquid Waste Management -Sub Work 1 - 10 KLD Public Leach Pit Item No 1 - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 2 Item No 1 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 3 Item No 1 - Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) 0 to 1.5 m 4 Item No 2 :- Providing and laying in situ Cement Concrete M- 15 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38. 5 Item No 3 - Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 6 Item No 4 - Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Item No 5 - Providing and casting in situ C.C. of trap / granite/ quartzite /gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 8 Item No 6 - Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 9 Item NO 7 - Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 0.90 X 0.60 10 Item No 8 - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification по. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 11 Sub Work 2 - 150 KLD CAMUS SBT Sewage Treatment Plant Item No 1 - Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering. preparing the bed for foundation and excluding backfilling, etc complete. (BdA1/259) 0.0 to 1.5 m 12 1.5 to 3.0 m 13 3.0 to 4.5 m 14 Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259) 0.0 to 1.5 m 15 1.5 to 3.0 m 16 3.0 to 4.5 m 17 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259) 0.0 to 1.5 m 18 1.5 to 3.0 m 19 3.0 to 4.5 m 20 Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering. excluding backfilling, etc. complete by all means. (BdA6/259) 0.0 to 1.5 m 21 1.5 to 3.0 m 22 3.0 to 4.5 m 23 Providing dry trap/granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264) 24 Providing and laying in situ Cement Concrete M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. Bd E /1 Page No. 287 and B 7,for Beam/Braces/Lintels in PCC 25 Providing and layingin situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 26 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 27 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 28 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas/Parapets/Curtains Walls / Partition Walls/Pardies in RCC M 300 29 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) 30 Providing and fixing mild steel grill work for windows/ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) 31 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 32 Providing and applying whitewash in two coats on old/new plastered or masonry surfaces and asbestos cernent sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 33 Providing and applying colourwash of approved colour and shade in 136.95 one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc, complete. 34 Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc, complete. (BdA9/261 35 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 36 Transportation as per STATEMENT VI Including loading, unloading and stacking Screen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bend Quotation Item Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 37 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 38 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 9000 LPH Supply 39 2 HP upto 9000 LPH Erection 40 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 12000 LPH Supply 41 2 HP upto 12000 LPH Erection 42 NaOCI Chlorinator Pump Diaphragm Type/peristaltic type / Solenoid Max Flow Power source Eletric Phases Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 Nos Quotation Item Designing, Supplying, Installing, commissioning & testing of PLC Panel Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. Control Panel 43 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 44 Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 7.5 HP & upto 12.5 HP 45 Erection 46 Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core16sqm supply 47 Erection 48 Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/ on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 2.5 sqm mm supply 49 Erection 50 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Unarmoured control cable with ISI mark stranded/solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner 4 Core 2.5 sqm mm supply 51 Erection 52 Piumbing Item - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material l.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). Raw Sewage pump to10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates CAMUS Distribution Main header 75 mm 53 PVC Specials 54 Distribution 63 mm 55 PVC Specials 56 CAMUS Collection 75 mm 57 PVC Specials 58 Collection tributory 63 mm 59 PVC Specials 60 CAMUS Distribution 63 mm 61 PVC Specials 62 Plumber 63 Helper 64 Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass) Raw Sewage pump 80 mm 65 Providing and supplying ISI mark CI D/F reflux valves (non return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.5.5312 Part I (1984) Without by pass arrangement PN 1 Raw Sewage pump 66 Providing, laying, spreading in layers stone aggregates of specific size as a Bio media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. complete Supplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 67 As Per Rate Analysis Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including 3.0 conveying & stacking 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 68 Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd 69 Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete 70 Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness). (As per P&G DSR 2022-23 Items of garden work, Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR required variety of lawn (free from weeds / diesease etc.) Cynadon/paspalum/selection for 1 sqm. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work, Sr No.46) 71 Excavation for planting lawn/shrub/flower bed/hedges/ edges/canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.3), Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.13), Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flower bed/ hedges/edges/canna bed/ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work, Sr No.23), Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/selection) (As per P&G DSR 2022-23 Items of garden work, Sr No.28) 72 Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,. Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018 73 Providing Energy Meter Application Fees Energy Meter Fee 74 Sub Work 3 - 100 KLD CAMUS SBT Sewage Treatment Plant Item No 1 - Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering. preparing the bed for foundation and excluding backfilling, etc complete. (BdA1/259) 0.0 to 1.5 m 75 1.5 to 3.0 m 76 3.0 to 4.5 m 77 Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259) 0.0 to 1.5 m 78 1.5 to 3.0 m 79 3.0 to 4.5 m 80 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259) 0.0 to 1.5 m 81 1.5 to 3.0 m 82 3.0 to 4.5 m 83 Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering. excluding backfilling, etc. complete by all means. (BdA6/259) 0.0 to 1.5 m 84 1.5 to 3.0 m 85 3.0 to 4.5 m 86 Providing dry trap/granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264) 87 Providing and laying in situ Cement Concrete M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. Bd E /1 Page No. 287 and B 7,for Beam/Braces/Lintels in PCC 88 Providing and layingin situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 89 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 90 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 91 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas/Parapets/Curtains Walls / Partition Walls/Pardies in RCC M 300 92 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) 93 Providing and fixing mild steel grill work for windows/ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) 94 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 95 Providing and applying whitewash in two coats on old/new plastered or masonry surfaces and asbestos cernent sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 96 Providing and applying colourwash of approved colour and shade in 136.95 one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc, complete. 97 Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc, complete. (BdA9/261 98 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 99 Transportation as per STATEMENT VI Including loading, unloading and stacking Screen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bend Quotation Item Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 100 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 101 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 9000 LPH Supply 102 2 HP upto 9000 LPH Erection 103 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 12000 LPH Supply 104 2 HP upto 12000 LPH Erection 105 NaOCI Chlorinator Pump Diaphragm Type/peristaltic type / Solenoid Max Flow Power source Eletric Phases Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 Nos Quotation Item Designing, Supplying, Installing, commissioning & testing of PLC Panel Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. Control Panel 106 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 107 Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 7.5 HP & upto 12.5 HP 108 Erection 109 Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core16sqm supply 110 Erection 111 Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/ on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 2.5 sqm mm supply 112 Erection 113 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Unarmoured control cable with ISI mark stranded/solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner 4 Core 2.5 sqm mm supply 114 Erection 115 Piumbing Item - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material l.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). Raw Sewage pump to10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates CAMUS Distribution Main header 75 mm 116 PVC Specials 117 Distribution 63 mm 118 PVC Specials 119 CAMUS Collection 75 mm 120 PVC Specials 121 Collection tributory 63 mm 122 PVC Specials 123 CAMUS Distribution 63 mm 124 PVC Specials 125 Plumber 126 Helper 127 Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass) Raw Sewage pump 80 mm 128 Providing and supplying ISI mark CI D/F reflux valves (non return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.5.5312 Part I (1984) Without by pass arrangement PN 1 Raw Sewage pump 129 Providing, laying, spreading in layers stone aggregates of specific size as a Bio media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. complete Supplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 130 As Per Rate Analysis Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including 3.0 conveying & stacking 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 131 Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd 132 Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete 133 Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness). (As per P&G DSR 2022-23 Items of garden work, Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR required variety of lawn (free from weeds / diesease etc.) Cynadon/paspalum/selection for 1 sqm. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work, Sr No.46) 134 Excavation for planting lawn/shrub/flower bed/hedges/ edges/canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.3), Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.13), Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flower bed/ hedges/edges/canna bed/ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work, Sr No.23), Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/selection) (As per P&G DSR 2022-23 Items of garden work, Sr No.28) 135 Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,. Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018 136 Providing Energy Meter Application Fees Energy Meter Fee
Contract Date: Dec 03, 2025 Contract Value : 92.41 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
29.
Defence #8303483 AOC
Tender For Construction Of Children School At Af Stn Nal; 1 SCHEDULE `A PART - I (Building / Structure Works) is not prepriced by MES and prepriced rates indicates0.00 under column 5 signifies this fact only. 2 Design and construction ofChildren school Building (Double Storey)including staircases, open to sky play area, planter box, 25000 litres RCC water tanks etc with permanent specifications ,complete all as specified and as shown in drawings. 3 Design and construction of Parking shed for 5 Cars(Single Storey) complete withpermanent specifications,complete allas specified and as shown in drawings. 4 Design and construction of Parking shed for 25 Cycles (Single Storey) complete withpermanent specifications,complete allas specified and as shown in drawings. 5 Design and constuction of Sentry Post (Single Storey) ,complete withpermanent specifications complete all as specified and as shown in drawings. 6 Design and construction of Service toilet with permanent specifications, complete allas specified and as shown in drawings. 7 Construction of RCC Septic tank (conventional type; for 50 users) designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter all as shown on drawings. 8 Construction of soakage well of 3.0 m dia and 4.5 mtr effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover interconnecting pipes of RCC/DWC complete filled with brick bats all as shown on drawings. 9 Construction of steel gate 5.50 RM wide and 2.1 m height including M25 design mix RCC column footing and column, earth work in any type of soil, lean concrete 1:4:8 type D2 15 mm thick, finishing etc. for children school 10 Construction of steel gate 1.8 RM wide and 2.0 m height including M25 design mix RCC column footing and column, earth work in any type of soil, lean concrete 1:4:8 type D2 15 mm thick, finishing etc. for children school 11 NOTE: Schedule ‘A’ Part IIto XII under Ser No 2.01 to 2.10 are Prepriced by MES. 12 Lump sum price worked out by the Contractor for “ SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’Part II 13 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY WORKS ” as listed in Schedule ‘A’Part III 14 Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’Part IV 15 Lump sum price worked out by the Contractor forSEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’Part- V 16 Lump sum price worked out by the Contractor for“ROAD, PATH AND HARDSTANDING WORKS ” as listed in Schedule ‘A’Part- VI 17 Lump sum price worked out by the Contractor for“EXTERNAL ELECTRIFICATION WORKS” as listed in Schedule ‘A’Part -VII 18 Lump sum price worked out by the Contractor for EXTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’Part VIII 19 Lump sum price worked out by the Contractor for “STAGE FOR CHILDREN as listed in Schedule ‘A’Part IX 20 Lump sum price worked out by the Contractor for “FIRE POINT as listed in Schedule ‘A’Part X 21 Lump sum price worked out by the Contractor for “FIRE FIGHTING as listed in Schedule ‘A’Part XI 22 Lump sum price worked out by the Contractor for “BOUNDARY WALL as listed in Schedule ‘A’Part XII 23 Lump sum price worked out by the Contractor for “VERMICOMPOST WORKS as listed in Schedule ‘A’Part XIII 24 Lump sum price worked out by the Contractor for ARBORICULTURE WORKS” as listed in Schedule ‘A’Part -XIV 25 Lump sum price worked out by the Contractor for FLAG STAFF” as listed in Schedule ‘A’Part -XV 26 SCHEDULE `A PART - XVI MISC ITEMS (B/R & E/M, srl Item No.3.01 to 4.08)is not prepriced by MES and prepriced rates indicate 0.00 under column 5 signifie this fact only. 27 INTERNAL WATER SUPPLY 28 S&F brass chromium plated center hole basinmixer w/o pop up for each hot and cold water each screwed down for iron pipe and fixed complete all as specified and directed 29 S&F toilet grab handle bars for toilet 23.6 inch aluminium alloy flip up handicap safety all as specified and directed. 30 INTERNAL ELECTRIC SUPPLY 31 S&F sheet metal enclosures VTPN DB 8 ways 415 Volts, double door type isolated neutral with door earthing and bus bar capacity 200 Amps complete all as specified and directed. 32 ROAD PATHWAY AND HARDSTANDING 33 M&L for applying road marking paint white/yellow(2.0mm thick) centre line,stop line, dashes, arrow, brackets & similar work on road surfaces as per IRC pattern.retro-reflective type specified shade/colour using hot thermoplastic maerial by automatic thermoplastic paint applicator machine filted with profile shoe glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cleaning the road surface and remove all dirt, seals, oil,grease and foreign material etc. complete all as per manufacturers instructions and as per direction complete all as specified and directed. 34 Supply and fixing of precast grass concrete Paver Block any shape and size of 60 mm thickness set on compacted earth and joined with suitable earth including supply and plantation of grass selection I variety by dibbling root method complete including all the materials, labour, T&P, manure, fertilizers, other additives etc required for the activities for completion of said work and also shown in the note here-in-below:-Note: The following activities are to be carried out at site for planting of grass and the rate quoted against this item shall be deemed to include the cost of same, including necessary material, labour and T&P complete :(a) Anti-termite treatment: Providing and spraying BHC powder over soil over the area / lawn where grass to be provided(b)Dressing and levelling the soil to the required gradient and slope completion of operation as mentioned in (a) above.(c) Well decayed Okhala manure in the proportion 3:1 (3 part soil: 1 part manure) shall be mixed with soil where grass to be planted.(d) Poring of water as required till completion of work 35 EXTERNAL WATER SUPPLY 36 Construction of valve pit chamber with inner clear dimension 600 x 600 x 900mm suitable for 80mm sluice Valves with PCC (1:4:8) 150mm thick type D2 for foundation, Brick masonary 230mm wall in CM (1:4), PCC (1:2:4) 75mm type B1 for coping, rendering in CM (1:4) 15mm thick including provisiion of 3mm thick MSsheet cover and 25 x 25 x 3mm angle iron frame embeded in coping with two coats of synthetic enamel paint over a coat of red oxide primer with locking arrangements including necessary earth work complete all as specified and ahown on drawing as directed by Engr-in-charge 37 Material and Labour for cutting of hole in existing pipe line Gl/DI size 100/150 mm including fitting and welding works complete all as specified and directed by Engr-in charge. 38 EXTERNAL ELECTRIC SUPPLY 39 Supplying, Fixing, Testing & Commissioning of indoor type LT Panel- IP 54 Type (Panel must be as per IS 61439 part 1 & 2) & CPRI Approved manufacturer, Powder coated enclosure made out of TATA/SAIL/ESSAR make CRCA sheet having 2 mm for load bearing surfaces & 1.6 mm for NON load bearing surfaces ,duly processed powder coated having siemens grey colour incl channels / MCB / channels/fibreglass/ gaskits/ sleeves/ nuts/ bolts / washers / cooling /fans /etc) with wiring inclusive of thimbles, etc and as per following specification as :-(a) INCOMING MCCB 1 No. of 250 Amps MCCB, 4P thermal release with ROH, adjustable, O/C, S/C release, MCCB with Ics=Icu=Icw 65KA having Micro processor based releases for O/L, S/C & E/F. (b) 1 Set of 400 Amp, 65 KA for 3 sec PN Electrolytic Copper busbar, current density 0.8 Amp per sq.mm with colour coded PVC sleeves (C)OUTGOING MCCB:(i) MCCB 4 Pole 160 A,50KA-04Nos(d) METERING & INDICATION(i) 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage current, Hz, KW, KWHr, PF.) with RS 485 port with matching cast resin CTs (ii) LED indication lamp set-01 Set of three 40 Supply Install, and testing MCCB 250A 4 pole 50 KA on existing LT panel including necessary addition/alterations all as dircted 41 S & F Junction box (Bus bar chamber box) of minimum size 300 x 200x 200 mm, protected to IP-65, made out of palstic suitable for 415 Volt, 4 Way TPN aluminium bus bars of capacity 63A amps with 01 No. MCB, SP, 6 Amp, 240 volts, 10 KA for controlling the street light complete fixing arrangement to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles including taking out existing unsv junction box complete all as directed. 42 S & F GI pipe 40 mm dia, light grade for cable protection fixed along the pole, with 02 Nos of MS clamps of suitable size made out of thick flat iron including nuts bolts and washers including taking out existing with complete all as directed by Engineer in charge. 43 ARBORICULTURE 44 Supplying and planting below mentioned best quality grown trees of 8-10 ft height plants at site including transportation of plants, pit digging 0.9m x 0.9m x 0.9m in ordinary soil, including HEDGE around trees and refilling the same with the excavated soil mixed with manure, fertilizers and chemicals as may be required and remaing soil removal distance of 50 m and lift upto 1.50m complete all as specified and directed. 45 (a) ALSTONIA SCHOLARIS (BLACKBOARD TREE) 46 (b) LAGERSTROEMIA SPECIOSA (JARUL) 47 (c) AZADIRACHTA INDICA (NEEM) 48 (d) MIMUSOPS ELENGI (MAULSARI) 49 (e) ALSTONIA MACROPHYLLA (DEVIL TREE) 50 (f ) PLUMERIA OBTUSA (CHAMPA) 51 (g) DELONIX REGIA (GULMOHAR) 52 Complete maintainance of approximately 200 trees newtrees like making of basin at regular interval watering, weeding application, manuaring and fertilizer application etc after completion of work complete all as specified and directed by Engr-in-Charge.Note: If any plant/tree planted is found dead during this period, the same shall be replaced with same age and size. 53 FIREFIGHTING WORKS 54 Supply and install test and commissioning of starter pannel fabricated for automatic Each operation of 450/900 Lpm terrace pump or cappable for start uptob10Hp pump and having provision for automatic starting by pressure switches ,controll mounting shall include neccessary lamp indication, ammeter for motor load circit with CT and selector switch,volt meter with auto mannual selector swith. The pannel shall be duly painted with protective anty corrossive paint and shall be foot/wall mounted type including all accessories. 55 M & L for ISI marked, 3 core 6 sqmm copper control cable as per relevent IS code and complete all as specified and as directed. 56 Note :- The contract sum shall be arrived after deducting the amount of credit as NIL from total quoted amount of BOQ and accordingly lowest bidder shall be ascertained.
Contract Date: Nov 21, 2025 Contract Value : 6.27 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
30.
Defence #8274121 AOC
Tender For Provision Of Different Offrs Md Accn At Ahmedabad Mil Stn - 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No.29 2 Lump sum price worked out by the contractor for SITE CLEARANCE, EXCAVATION & EARTH WORKas listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 30 3 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 31 4 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 32 to 36 5 Lump sum price worked out by the contractor for ROAD/FOOT PATH/ CULVERT WORKS as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 37 to 40 6 Lump sum price worked out by the contractor for AREA DRAINAGE WORKSas listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 41 7 Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 43 8 Lump sum price worked out by the contractor for COMPOUND WALL , FENCING AND STEEL GATE WORKSas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No.44 to 46 9 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKSas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 47 10 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 48 to 51 11 Sch A PART-XI (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule. 12 INTERNAL WATER SUPPLY OFFR ACCN Md Accn Supply and fixing of15 mm dia fancy type chromium plated bib taps with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed.Make - Jaquar Cat part No.VGP-81037 or equivalent of any make specified in Appx C. 13 Supply and fixing of15 mm dia fancy type chromium plated pillar cock with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed.Make - Jaquar Cat part No. ORP-10001PM-7037 or equivalent of any make specified in Appx C. 14 Supply and fixing 15 mm borefancy type chromium plated central hole basin mixerwith popup waste system wiyh 450 mm long braided hosesfor iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. 15 Supply and fixing of 15 mm dia fancy type chromium plated angular stop cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed.Make - Jaquar Queen series Cat part No.QQT-7053 or equivalent of any make specified in Appx C. 16 Supply and fixing of 15 mm bore CP wall mixer of 3 in 1 system with provision for hand shower and over head shower and including 1.5 m long tele shower screwed for iron pipes or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Queen series Cat part No.QQT-77281 orequivalent of any make specified in Appx C. 17 Supply and fixing for 15 mm bore fancy type chromium plated single lever sink nixer with swinging spout on upper side (wall mounted modle) with connecting legs & wall flanges and fixed complete all as specified and as directed.Make - Jaquar Queen series cat part No. FON-40165orequivalent of any make specified in Appx C. 18 Supply and fixing for overhead shower 150x150mm of square shape single flow with rubit cleaning systemABS body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and as directed.Make - JaquarQueen series cat part No.OHS-35495 or equivalent of any make specified in Appx C. 19 Supply and fixing health faucet (ABS Body) with 1200 mm long flexible mild steel tube 15 mm dia with wall hook and complete all as specified and as directed.Make - JaquarQueen series cat part No.ALD-573 or equivalent of any make specified in Appx C. 20 Servant Md AccnSupply and fixing of15 mm dia fancy type chromium plated bib taps with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. Make - Jaquar/Essco Seriesor equivalent of any make specified in Appx C. 21 Supply and fixing of 15 mm bore fancy type chromium plated sink cockwith swinging spout (Wall mounted Model) With Connecting Legs & wall fllanges and fixed complete all as specified and as directed.Make - Jaquar/Essco Seriesor equivalent of any make specified in Appx C. 22 Supply and fixing of 15 mm dia fancy type chromium plated angular stop cock with wall flange, screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. Make - Jaquar/Essco Seriesor equivalent of any make specified in Appx C. 23 Supply and fixing of15 mm bore Overhead shower of 114 x 114 mm of square shape single flow with rubit cleaning system ABS body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and as directed.Make - Jaquar/Essco Seriesor equivalent of any make specified in Appx C. 24 INTERNAL ELECTRIFICATIONSupply and fixing load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 4 pole 200 Amps, 16 KA, busbars ,neutral link, blanking plates complete with all accessories all as specified and as directed by Engineer-in-Charge. Note: Outgoing MCBs shall be measured and paid separately 25 Supply and fixing TV sockets complete with all accessories all as specified and as directed by Engineer-in-Charge. 26 Supply and fixing RJ 11 Gang with shutter (Telephone Jack) complete with all accessories all as specified and directed by Engineer-in-Charge 27 Supply and fixing wall mounted fan 450mm sweep,5 star rated with speed regulater,less noice, PVC body,180 degree rotated ,all including connection with single core PVC insulated but unsheathed, FRLS cable with multistranded copper conductors IS 694 marked, from ceiling rose to fan complete all as specified and as directed by Engr-in-Charge. 28 Supply & fixing of PVC metal braided connection pipes for hot water supply with brass adopters 15 mm dia and 450mm long complete all as specified and as directed. 29 Supply & fixing LED lampB22 base 10 W, min lumen output 950 lumens at 6500 K CCT for batten holderscomplete all as specified and as directed. 30 Supply and fixing of decorative, wall mounting, brushed nickel finish fixture with opal glass diffuser suitable with 9 W LED lamp B22 base including all electrical connections complete all as specified and as directed 31 M & L for inverter point wiring for one light, ceiling fan and 5 Amp socket for each roomwith 2.5 sqmm, PVC insulated, unsheathed, single core multistandard copper conductor cable ( FRLS), 1100 volts grade including 2.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI markedwith its acessories upto the main DBand 15 A switch socket combination with gang box flushed in wallfor inverter power supplycomplete all as specified and as directed. 32 Supply and fixing of LED security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDsinbuilt electronic driver up to 4KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT5500-6500 CRI greater than 70 , input power 30Woutput operating voltage 140-280V with connection by three core PVC insulatedmultistranded copper conductor sheathed cable of size 1.0 sq mmfixed with & including bracket made of GI pipe 40mm bore light grade, 1.6 mtr long bent to shape required with 2 no MS clamps of suitable size and length, nuts & boltscomplete all as specified and as directed. 33 M & L for drawing 12 pair /multi core coated copper telephone cable including PVC conduit of size 20mm complete all as specified and as directed by Engr-in-Charge 34 M&L for bringing approved earth from outside defence land for filling in the site of the work including necessary excavation, transportation and payment of rolyalt etc to bodies complete all as specified and directed. 35 COMPOUND WALL , FENCING AND STEEL GATE WORKSSupply and fixingof CI wheel as rollers of 75mm dia for gatescomplete all as specified and as directed. 36 EXTERNAL WATER SUPPLY WORKSSupply and fixing of 80 mm Gun-metal, globe or gate valves, with iron wheel head , screwed both ends for iron pipes complete all as specified & directed. 37 M&L forconstruction of brick masonarry new valve pit chamber of size 600mm x 600mm x 600mm (internalsize) with 100mm thick PCC 1:4:8 type D-2 lean concrete foundation using 40mm graded crushed stone aggregate providing well burnt brick masonary wall of 23 mm thick built in cement mortar 1:6rendering in cement mortar 1:6 finished even smooth using extra cement internally and 20mmthickin cement mortar 1:4and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mmx 50mmx 6mm thick angle ironframe embbeded in PCC copingwith locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplyingtwo coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed. 38 M & L for Cutting existing cast iron pipes 150mm dia and reducing to required length in position for insertion of new tees, branches, S&F of CI Tee 150x150x80mm all flanged fixing to existing pipe by providing two Numbers Mechanical joints of 150mm size complete with nut bolts, gasket all as specified and as direcetd by Engineer In Charge 39 EXTERNAL ELECTRIFICATION WORKSSupplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 250 KVA capacity transformer, step down, outdoor type, 11000/433 volts (at no load) with system voltage 12KV all as per IS 1180 (Part 1):2014, copper wound, oil immersed, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of 2.5 % from (+) 5% to (-) 10% on primary side by means of hand operated off load tap changing gear, so as to change/correct L.T voltage on secondary side including provision of all necessary / standard fittings all as per IS:2026 & IEC 76 Latest ammendments and confirming to BEE 5 Star Rating (Level 3 transfomer) as per IS 1180 (Part 1):2014 with all necessary arrangments and comprising of following :- 40 (a) The core shall be stack/wound type of high grade Cold Rolled Grain Oriented or Amorphous Core annealed steel lamination having low loss and good grain properties, coated with hot oil proof Inter layer insulation of Nomex /Epoxy dotted Kraft Paper, bolted together and to the frames firmly to prevent vibration or noise. The core shall be stress relieved by annealing under inert atmosphere if required.The complete design of core must ensure permanency of the core loss with continuous working of the transformers. LV winding shall be such that neutral formation will be at top. Current density for HV and LV winding should not be more than 2.8 Ampere per sq mm(b)The maximum allowable losses at 75 °C & 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 864watts and 2488watts respectively for 11/0.433 kV transformer without any positive tolerance all as per specified for level 3 transformer as in IS 1180 (Part-1):2014 Ammendment No 4(c) Overload capacity of transformers shall be suitable for loading as per IS 6600.(d) The percentage impedance of transformers at 75 °C for 250 kVA shall be 4.5% ,as per Table 6 of IS 1180 (Part-1) : 2014 (e) Transformer tank construction shall conform in all respect to clause 15 of IS 1180(Part-1):2014. The internal clearance of tank shall be such, that it shall facilitate easy lifting of core with coils from the tank without dismantling LV bushings. All joints of tank and fittings shall be oil tight and no bulging should occur during service. Inside of tank shall be painted with varnish/hot oil resistant paint.The top cover of the tank shall be slightly sloping to drain rain water. The tank plate and the lifting lugs shall be of such strength that the complete transformer filled with oil may be lifted by means of lifting shackle.Manufacturer should carry out all welding operations as per the relevant ASME standards. The transformer tank shall be of robust construction and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for the bottom and top and not less than 4 mm for the sides for distribution transformers with Tolerances as per IS-1852.The space above oil level in the tank shall be filled with dry air or nitrogen conforming to commercial grade of IS 1747. The tank shall further be capable of withstanding a pressure of 0.8kg/sq.cm and a vacuum of 0.7 kg/sq.cm (g) without any deformation. 41 (f) Audible sound levels for liquid immersed distribution transformers shall be 56 decibels (NEMA Standards)(g) One cable box on primary H.V side having cable glands suitable for 95Sqmm 3 core XLPE 11 KV H.T cable consisting of 3 Nos porcelain H.T bushings with brass/ gun metal bushing rods confirming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers.HT Cable box should prevent the ingress of moisture into the box due to rain water directly falling on the box. The cable box on HT side shall be of the split type with faces plain and machined and fitted with Neo-k-Tex or similar quality gasket and complete with brass wiping gland to be mounted on separate split type gland plate with nut-bolt arrangement and MS earthing clamp. The bushings of the cable box shall be fitted with nuts and stem to take the cable cores without bending them. The stem shall be of copper with copper nuts. The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight. (h) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with GMbushing rods complete with GM nuts, and washers with cable gland suitable for reception of outgoing L.T. PVC sheathed armoured cables of size 2 x 300 sqmm 3.5 core . having non-magnetic material gland plate with appropriate sized single compression brass glands on LV side to terminate 1.1 kV/single core XLPE armoured cable.(j) The bushing rods and nuts shall be made of brass material 12 mm diameter for both HT and LT bushings. The bushings shall be fixed to the transformers on side with straight pockets and in the same plane or the top cover . The tests as per latest IS 2099 and IS 7421 shall be conducted on the transformer bushings.(k) OIL CONSERVATOR:The provision of conservator is mandatory with oil gauge, air release plug andbreathing device with a drain plug and a filling hole 32 mm (1¼”) normal size thread with cover. The dehydrating agent shall be silica gel. The moisture absorption shall be indicated by a change in the colour of the silica gel crystals which should be easily visible from a distance. Volume of breather shall be suitable for1Kg of silica gel conforming to IS 3401. The total volume of conservator shall be such as to contain 10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator. 42 (m) The radiators can be tube type or fin type or pressed steel type to achieve the desired cooling to limit the specified temperature rise.(n) Transformer to be painted with poly urethene/powder caoted (color light gray & DA gray) paints over anti corrosive primer & shall be free from runs, sags, wrinkles, patchiness, brush marks or other defects.All primers shall be well marked into the surface, particularly in areas where painting is evident and the first priming coat shall be applied as soon as possible after cleaning. The paint shall be applied by airless spray.(p) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, maxtemp indicator and resetting device(q) Rating plate with terninal markings.(r)Two earthing terminals on tank/tank cover to facilitate fixing of 32 x 6 m GI earth strip.(s) Lifting lugs.(t) Four plane solid cast steel detachable rollers.(u) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103.(v) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral.(w)Provision of 2 Nos danger boards 250 x 200 mm size made out of 1.6 mm thick M.S. plate, vitreous enameled white, with letters. figures of voltage and conventional skull and bones insignal red colour , one at H.T side and other on L.T side.(x)Any other fittings / accessories so as to conform the whole transformer toIS 1180 (Part 1): 2014 (y) The DistributionTransformers to be supplied against this Specification shall be suitable for satisfactory continuous operation under the following climatic conditions as per IS 2026(Part-I):(i) Location:Ahmedabad(ii)Maximum ambient air temperature:50 °C(iii) Minimum ambient air temperature :5°C(iv) Maximum average daily ambient air temperature:42 °C(v)Maximum yearly weighted average ambient temperature : 32 °CThe temperature rise over ambient shall not exceed the limits given below:(i) Top oil temperature rise measured by thermometer : 35 °C(ii) Winding temperature rise measured by resistance method : 40 °C 43 (x)Any other fittings / accessories so as to conform the whole transformer toIS 1180 (Part 1): 2014 (y) The DistributionTransformers to be supplied against this Specification shall be suitable for satisfactory continuous operation under the following climatic conditions as per IS 2026(Part-I):(i) Location:Ahmedabad(ii)Maximum ambient air temperature:50 °C(iii) Minimum ambient air temperature :5°C(iv) Maximum average daily ambient air temperature:42 °C(v)Maximum yearly weighted average ambient temperature : 32 °CThe temperature rise over ambient shall not exceed the limits given below:(i) Top oil temperature rise measured by thermometer : 35 °C(ii) Winding temperature rise measured by resistance method : 40 °C 44 M&L for Transformer platform 250 KVA out door type made of brick masonry size 2000mm x 2000mm x 1400mm, over PCC foundation 1:3:6 type C-2,with brick work sub classB bricks in cement motar 1:4 and plaster work 10mm thick in cement plaster 1:4 incl sand filling and elevated with Angle iron guard rail of 600mm heightwelded with M.S Angle iron 60x60x6mm, MS flat 50x6mm for interlocking arrangements and guard rails wire netting of galvanized steel wire 1.40mm dia with 25x25mm mesh size fixed with tinned tracks of wire staples duly painted with two coat of synthetic enamel aluminium/smoke grey paint over a coat primer complete all as specified and as directed. 45 Supply, install, testing and commissioning of feeder pillar box CPRI approvedoutdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 400 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following. 46 (a) Incomer(i) ) MCCB 4 pole adjustable thermal 415 volts 320 Amps 35 KA - 01 Nos(ii) Supply & fix Digital panel meter for Amp, Volt, KWH, power factor and other parameter flush mounting of size 96 x96 mm-01No(iii) Digital volt meter 3 phase 0-500 volts(iv) Indicating lamps LED type, 230 volts for RYB including all necessary arrangments - 01 Set(b)Out going(i) MCCB 4 Pole adjustable thermal 415 volts 200 Amps 35 KA - 02 Nos(ii) MCCB 4 Pole adjustable thermal 415 volts 63Amps 25 KA - 02 Nos 47 Supplying, installation, Connecting electrically & commissioning and testing of Outdoor type free standing type (IP -42) automatic power factor correction system with both auto and manual options type Inlet Var APFC Panel with MD - XL capacitors and MCCB as incomer factory made Non compartmentalised single unit 440 Volts 50 Hz , 3 phase 100 KVAR (Multiple of 5 KVAR) Complete all as specified and as directed including the following : 48 (a) Double Metallized paper with polypropylene film cylinderical, type MD-XL capacitor bank of rated voltage 525 volts with detuned Reactor of de - tuning factor (P) 7% and suitable output of 100 KVAr at 440 Volts confirming to IS-13340, 13341, & IEC - 60831 - 1+2.(b) Capacitor duly contactor with Damping Resistors appropriate rating for capacitor switching confirming to IEC - 60070 & IS 13947. (c) Automatic power factor controller relay micro processor based for switching ON & OFF of capacitors and suitable to display of voltage , current, active power, Reactive power, Apparent power, Display of power factor, THD Voltage, THD current, alarm indication for defective steps, low power factor and excess temperature. The relay has volt free c/o contact, Automatic detection and usage of optimum capacitors.(i) Capable of 4 - Quadrant operation, and any phase offset requirement.(ii) Swithching programms : LIFO, Combi - filter, manual mode.(iii) Build in under and over voltage release with auto reset.(iv) Large Voltage input band of 90 Volt to 550 Volt , 45 - 65 Hz.(v) Current measuring 10 mA - 5A , Suitable for CT x/1A and x/5A.(vi) Commissioning without additional settings and programming.(vii) Three decimal power factor reading. 49 (d) Multifunction meter having digital volt meter and ammeter of range as required and recommended by manufacturer with in built selector switch and CTs of appropriate ratio with percentage load bar graph (Model EM 6459) equivalent.(e) MCB D , 3 Pole, 415 Volts Curve type with rupturing cap 10 kA of appropriate rating for protection of individual capacitor bank conf to IS 8828, IEC 898.(f) Incoming TPN MCCB, 400 Amps, Ics = 100% Icu , 25 KA, 4 Pole. (g) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending the temperature of the panel.(h) Emergency stop push button to disconnect the unit in case of emergency.(j) Indicator LED type for phase indication and capacitor banks ON and OFF indication. (k) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to withstand high temperature, housed in cubical panel (CPRI Approved) made out of 3.15 mm thick MS sheet factory made duly powder coated front and rear door openable with locking arrangement complete with foundation as required or recommended by manufacturer. 50 DEMOLITION AND DISMANTLING WORKSDemolition/dismantling of (Bldg No P-2,P-2/F, P-2H, P-2/B-II, P-2/B-I, NP-225 and P-7) any discripition and in any position excluding E/M fittings & fixtures complete As is where is all as specified and directed. 51 NOTE FOR ITEM No 17.00:- The quoted rate shall deemed to include the following:-(i)The demolition of Bldg shall be carried out upto ground level bearing all safety aspects into consideration including overlap with near by Bldgs and making good the ground.(ii) The quoted rate shall be deemed to include demolition of Bldgs except taking down/dismantling internal fittings and accessories of internal electric supply and internal water supply & all other items of demolition & dismantling of Bldgs specified eleswhere in the tender documents.(iii) Schedule of demolition/dismantling shall be decided by GE in the manner to recieve the amount of recovery for credit from RARs/ Final bill.(iv) Demolition of the buildings shall be carried out after taking down of all internal fittings/fixtures & after necessary approval of GE.(v) The quoted rate shall be deemed to include for removal of debries obtaind to out side MOD land including loading & unloading at destination as directed by Engg-in-Charge.(vi) All safety precautions shall be taken by contractor during demolition/dismantling of buildings as per latest by laws and as specified in SSR Part-I. 52 ARBORICULTURESurface excavation in any type of soil not exceeding 30cm deep and averaging upto 15cm and removing up to a distance n exc 50 metre filling back / spreading with red earth of 15 cm thick mixed with farm yard treating the soil with pesticides (i.e Bavitin and neam cake BHC 10% linsondustThimment and Phorate, super and vermi compost in ratio (1:3) incl turfing/laying of(Bermuda grass (Cynodon dactylon), Buffalo grass (Stenotaphrum secundatum) & Korean lawn grass (Zoysia japonica) ready made of approved quality turfs side by side without undualation/depressions and ramming the surface complete all as directed by Engineer-in-charge.Note:- Grassing shall be carried out to carpenting effect i.e. installation 80% of the ground shall not be visible due to plant cover if the desired effect is not obtained then additional grass will be planted as specified to achieve the effect. 53 Supply and plantation of Neem (Azadirachta indica) tree plant Height of sapling not less than 3 ftas approved by GE including excavation of suitable size pitn.exc 0.25 cum in any type of soil incl removal and filling back to pit with suitable growing media like red earth by treating with farm yead manure in the ratio (3:1) fertilizers and pesticides (i.e Bevation and neem cake BHC 10% linson dust.Thimment or phorate, manures super and vermicompost) and making up the trenh area to proper leveletc complete all as sepcified and directed by Engr-in-Charge. 54 All asper item No 18.01 above but Gulmohar (Delonix regia) 55 All asper item No 18.01 above but Peepal tree (Ficus religiosa) 56 All asper item No 18.01 above but Banyan (Ficus benghalensis) 57 All asper item No 18.01 above but Pink Cassia (Cassia javanica) 58 All asper item No 18.01 above but Christmas tree (Araucaria heterophylla) decorative plantsas directed by Engr-in-Charge 59 All asper item No 18.01 above but Golden Cane Palm (Dypsis lutescens) decorative plantsas directed by Engr-in-Charge 60 All asper item No 18.01 above but Royal Palm (Roystonea regia) decorative plantsas directed by Engr-in-Charge 61 All asper item No 18.01 above but Foxtail Palm (Wodyetia bifurcata) decorative plantsas directed by Engr-in-Charge 62 All asper item No 18.01 above but False Ashoka (Monoon longifolium) decorative plantsas directed by Engr-in-Charge 63 S & F of M.S Tree Guard 1.50 Mtrs high above with MS wiremesh of size 78 x 37 mm and 2 mm dia of wire and MS angle iron 20 x 20 x 3 mm verticals (3 Nos) & MS flats 14 x 3 mm around the tree guard (3 Nos top , middle and bottom) equally spaced and embedded vertical angles in PCC 1: 3:6Type B-I including excavation in post holes and removal of excavated material to a n.exc 5 mtr and applying two coats of synthetic enamel paint including one coat of red oxide primer to tree guard and all as specified and directed. 64 NOTE for Sl Item No 18.00 to 18.10 :-(i) Height of plant shall be measured from top of follage (not from the isolated branch/ leaf, main stem) to 150mm from top of root.(ii) Water will not be supplied by MES for arboriculture. Contractor has to make his own arrangement for watering to plants and grass. (iii) The rates quoted by the contractor deemed to include watering, maintenance of plants / grass till two years after certified date of completion of work.(iv). During two years after completion if any plant / grass is found dead or not of satisfactory growth, plants / grass of approved size and shape shall be provided without any extra cost to the Govt.(v). Supply and application of manure, sweet earth and pesticides, fertilizers etc up to two years after completion are deemed to be included in the quoted unit rate.(vi)In case offailure by the contractor to maintain the plants / grass as above, the same shall be carried out by the department at his Risk and Cost..(vii) The plants shall be brought at site Six months before the date of completion of the work as per Work order. 65 NOTE forSCHEDUL OF CREDITRs (-) 754873.00 amount to be deducted from total quoted amount at time of accptance of tender
Contract Date: Nov 17, 2025 Contract Value : 6.57 Crore
Statutory Bodies & Commissions/Committees No of Bidders 13
31.
Communications and Information Technology  #8271225 AOC
Bids Are Invited For Group C Wiring for light point , Wiring for light or power plug with 2 X 4 sq. mm FRLS , Wiring for light or power plug with 4 X 4 sq. mm FRLS , Wiring for circuit or submain wiring of size 2 X 1.5 sq mm and 1 X 1.5 sq mm earth wire , Wiring for circuit or submain wiring of size 2 X 2.5 sq. mm and 1 X 2.5 sq. mm earth wire , Wiring for circuit or submain wiring of size 4 X 2.5 sq. mm and 2 X 2.5 sq. mm earth wire , Supplying and fixing of 20 mm size of steel conduit , Supplying and fixing of 25 mm size of steel conduit , Supplying and drawing of 3 x 1.5 sq. mm sizes of FRLS , Supplying and drawing of 4 x 1.5 sq. mm sizes of FRLS , Supplying and drawing of 5 x 1.5 sq. mm sizes of FRLS , Supplying and drawing of 6 x 1.5 sq. mm sizes of FRLS , Supplying and drawing of 7 x 1.5 sq. mm sizes of FRLS , Supplying and drawing of 8 x 1.5 sq. mm sizes of FRLS , Supplying and drawing of 3 x 2.5 sq. mm sizes of FRLS , Supplying and drawing of 6 x 2.5 sq. mm sizes of FRLS , Supplying and drawing of 3 x 4 sq. mm sizes of FRLS , Supplying and drawing of 6 x 4 sq. mm sizes of FRLS , Supplying and drawing of 3 x 6 sq. mm sizes of FRLS , Supplying and fixing two module stepped type electronic fan regulator , Supplying and fixing modular blanking plate , Supplying and fixing suitable size GI box with 3 pin 5 or 6 amps modular socket , S F of suitable size GI box with 6 pin 5 or 6 and 15 or 16 amps , Supplying and fixing of 1 or 2 Module 75 mm X 75 mm size or modules GI box , Supplying and fixing of 3 Module 100 mm X 75 mm size or modules GI box , Supplying and fixing of 4 Module 125 mm X 75 mm size or modules GI box , Supplying and fixing of 6 Module 200 mm X 75 mm size or modules GI box , Supplying and fixing 8 Module 125 mm X 125 mm size or modules GI box , Supplying and fixing 12 Module 200 mm X 150 mm size or modules GI box , Supplying and fixing 18 Module 200 mm X 50 mm size or modules GI box , Supplying and fixing 5 or 6 amp switch modular switch or socket , Supplying and fixing 15 or 16 amp switch modular , Supplying and fixing 3 pin 5 or 6 amp socket outlet modular , Supplying and fixing 6 pin 15 or 16 amp socket outlet modular , Supplying and fixing bell push modular , Supplying and fixing modular indicator , Supplying and fixing of 4 Way 4 plus 12 ways Double Door surfaceor recess mounting , Supplying and fixing of Single pole 5 amps to 32 amps , Supplying and fixing of Triple pole 5 amps to 32 amps , Supplying and fixing 63 A four pole 415 volts isolator , Supplying and fixing 100 A four pole 415 volts isolator , Supplying and fixing 125 Amp 36 kA FP MCCB in existing cubicle panel , Supplying and fixing single pole blanking plate in the existing MCB DB , Supplying and fixing DP sheet steel enclosure on surface or recess along with 25 or 32amps 240 volts C curve DP MCB , Supplying and fixing TP sheet steel enclosure on surface or recess along with 16 or 25 or 32amps 415 volts , Supplying and fixing of 250 mm fresh air fan in toilet in existing opening , Supplying and Fixing 380 mm sweep 900 rpm heavy duty turbo force exhaust fan , SITC of 400 mm sweep oscillating type wall mounted cabin fan , Providing and fixing of S type or Fastener type fan hook , SITC of IP20 2 X 2 36 W LED Recessed mounting LED Light fixture , Replacement of old Conventional type CFL Lights with IP20 1 x 1 18W LED Surface mounting LED Light fixture , SITC of IP20 1 x 4 36W LED Surface mounting Mid power SMD type LED Light fixture , SITC IP20 18 - 20 watt LED batten type integrated light fixture , SITC of 415V 3 Phase 50 Hz 4 wire system sheet steel clad dust and vermin proof cubical , Dismantling, Servicing and complete repairing other than rewinding and ITC of 1200 mm ceiling Fan , Dismantling, servicing and repairing including Rewinding and ITC of 1200 mm ceiling Fan , Dismantling, servicing and repairing other than rewinding and ITC of 300 mm Exhaust Fan , Dismantling, servicing and repairing including rewinding and ITC of 300 mm Exhaust Fan , Dismantling, servicing and repairing other than Rewinding and ITC of 450 mm Exhaust Fan , Dismantling, servicing and repairing including rewinding and ITC of 450 mm Exhaust Fan , SITC 18 watt LED recessed mounted down lighter fitting , Supplying and fixing 5 or 6 Amp piano type switch on the existing switch box , Supplying and fixing 15 or 16 Amp piano type switch on the existing switch box , Supplying and fixing 3 pin 5 or 6 amp socket outlet on the existing switch box , Supplying and fixing 6 pin 15 or 16 amp socket outlet on the existing switch box , Replacement of broken or damaged phenolic laminated sheet cover on existing Switch box , Replacement of 40 watt fluorescent type tube Rod with 20 watt LED type tube rod in existing , Repairing and painting of existing 3 Mtr height Galvanized Mild steel pole , Repairing and painting of existing 7 Mtr height Galvanized Mild steel pole , SITC of 12 inch size Polycarbonate globe fittings alongwith 18 watt Energy Efficient LED , SITC of 60 Watt Energy Efficient LED Flood Light Luminaries with inbuilt High Power LEDs , Laying and fixing of one number PVC XLPE insulated and PVC sheathed XLPE power cable of 1.1 KV grade of Upto 35 sq. mm on surface , Laying and fixing of one number PVC XLPE insulated and PVC sheathed XLPE power cable of 1.1 KV grade of Upto 35 sq. mm in pipe , Laying and fixing of one number PVC XLPE insulated and PVC sheathed XLPE power cable of 1.1 KV grade of Upto 35 sq. mm in existing masonry open duct , Laying and fixing of one number PVC XLPE insulated and PVC sheathed XLPE power cable of 1.1 KV grade of Upto 35 sq. mm in ground , Laying and fixing of one number PVC XLPE insulated and PVC sheathed XLPE power cable of 1.1 KV grade of Upto 35 sq. mm in ground additional , Supplying and making end termination with brass compression gland and aluminum lugs for 2 X 6 sq mm 19 mm size , Supply of 1 no XLPE insulated and PVC sheathed power cable of 1 point 1 KV grade of size 2 x 6 sq mm Aluminum conductor armoured cable , Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing , Supplying and fixing digital weekly programmable time switch Astronomical Weekly Programmable alongwith 10 Amp 3 pole power contractor , Providing, laying and fixing 50 mm dia G.I. pipe A Class in ground complete with G.I. fittings including finishing etc as required. , Providing, laying and fixing 32 mm dia G.I. pipe A Class in ground complete with G.I. fittings including finishing etc as required. , Supplying and drawing 3 x 2.5 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing , Repairing of dust and vermin proof cubical out door double door type floor mounted , Replacement of faulty or damaged 400 Amp TPN Switch Fuse unit with HRC Fuses in Feeder pillar , Replacement of faulty or damaged 125 Amp TPN Switch Fuse unit with HRC Fuses in Feeder pillar , Replacement of faulty or damaged 63 Amp TPN Switch Fuse unit with HRC Fuses in Feeder pillar , Replacement of faulty or damaged 96 mm x 96 mm ampere meter with selector switch and 3 nos CT of suitable rating in Feeder pillar , Replacement of faulty or damaged 96 mm x 96 mm Volt meter with selector switch in Feeder pillar , Replacement of faulty or damaged 400 Amp din type HRC Fuses in Feeder piller , Replacement of faulty or damaged 125 Amp din type HRC Fuses in Feeder piller , Replacement of faulty or damaged 63 Amp din type HRC Fuses in Feeder pillar , SITC of borewell Submersible motor pump set in stainless steel internals like Rotor, pump shaft ,strainer suitable for discharge , Supplying and lowering of heavy duty UPVC pipe of size 50 mm dia ISI mark with other accessories for jointing , S and F 18 mm dia Nylon rope of double twisted for firmly holding of the submersible pump , S and L of 3 core 4 sq. mm flexible pvc insulated and pvc sheathed flat submersible cooper conductor cable , S and M connection of the pump with 65 mm dia Gate Valve for non rising stem ISI marked with test certificate Bronze , S and M connection of the pump with 65 mm dia B Class GI pipe for delivery and suction pipe line , Providing Fixing suitable M.S. sheet bore well cover with nut bolt etc as reqd , Pdg and fixing suitable size clamps for holding submersible pump pipe on top of borewell cover , Supplying and fixing 3 Phase 415 volts 50 Hz AC supply pump controller in sheet steel enclosure , SITC of centrifugal Type energy efficient Mono block pump with CI impeller suitable for a discharge , S and M connection of the pump with 80 mm dia foot valve ISI marked with test certificate Bronze screwed type , S and M connection of the pump with 80 mm dia Gate Valve for non rising stem ISI marked with test certificate Bronze screwed type , S and M connection of the pump with 80 mm dia Horizontal lift Check Valve ISI marked with test certificate Bronze screwed type , S and M connection of the pump with 65 mm dia Vertical lift Check Valve ISI marked with test certificate Bronze screwed type , S and M connection of the pump with 65mm dia Globe Valve for rising stem ISI marked with test certificate Bronze screwed type , S and M connection of the pump with 65 mm dia B Class GI pipe , S and M connection of the pump with 80 mm dia B Class G pipe , SITC of energy efficient 02 HP De watering Sewage sump Pump , SITC of 415V, 3 Phase, 50 Hz, 4 wire system sheet steel clad dust and vermin proof cubical , S and L fixing of one number XLPE insulated aluminum conductor armoud power cable of 1.1 KV grade of 4 X10 Sq mm size as required. , Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 10 sq mm , Providing and fixing 6 SWG dia G I wire on surface or in recess for loop earthing , Installation of 1 point 5 or 2 TR Capacity Split AC Units , Pdg and fixing 1 by 4 inch dia copper refrigerant piping , Pdg and fixing 5 by 8 inch dia copper refrigerant piping , Provision of Top Up or Additional Charging of R-22 or 32 gas , S F suitable size MS Stand for placement of split type AC outdoor unit , Providing and fixing 20 mm Dia heavy duty PVC pipe , Supplying and fixing 25 amp Moduler type starter , Supplying and fixing of 3 X 2.5 sq mm PVC insulated and FRLS , Earthing with G I earth plate , Providing and fixing G I strip in G I pipe , Providing and fixing G I strip on surface , Providing and fixing earth bus 50 mm x 5 mm copper strip on surface for connection etc as reqd , Supplying and fixing Flexile photo luminescent based Glow in the dark sheeting with luminous properties , Refilling of 4.5 Kg CO2 Type Fire Extinguisher
Contract Date: Ref. Documents Contract Value : 28.99 Lakh
Government Departments No of Bidders 4
32.
Defence #8184022 AOC
Tender For Replacement Of Water Supply Pipe Line Inside Cantt 600000 Gallon Water Treatment Plant At 20 Camp Pump House Under Ge Ramgarh; 2 SCHEDULE A PART-I A (Building Work)Design (Hydraulically, architecturally, structurally and aesthetically) and construction of underground sump of 30000 gallon (UK) capacity including with permanent specification RCC M30 (Design Mix) excavation in all type of strata foundation concrete container walls, bottom lab, local sump & foundation for pump/pipes, top RCC roof slab with C manhole covers, all surfaces are plaster with WPC including epoxy paint inside (bottom & sides) including all pipeline connections, valves, MS ladder, ventilation shaft and testing of water tightness and hydraulic functioning complete and necessary internal water supply & electrical suplly. Arch drawing of sump and WTP (site plan) approved by CWE/GE 3 Sch A Part-I B (Water Treatment Plant)Design (Architecturally, hydraulically, aesthetically and structurally), construting, commissioning and testing of water treatment plant 600000 gallons complete all as specified and directed. 4 NOTE : The basic requrement of Water Treatment Plant is as under for guidline :Design (Architecturally, hydraulically, aesthetically and structurally), construting, commissioning and testing of conventional water treatment plant 600000 gallons including cost of providing and applying epoxy paint to inside surface of water retaining structure in contact with chlorine and providing anti termite treatment to entire structure below ground level, Mechanical and electrical components of various sub-works as specifiedin scope of work, Design Basis Report, elsewhere in tender : including necessary hydraulic testing, structural testing, equipment testing and trial run for 03 months etc. complete including all pumping machinery all as specified and directed by Engr-in-charge and as per latest technolony and govt & this dept policy for portable water treatment plant. Treated water parameters for drinking water is as per IS 10500 :2012(Second Revision). Raw water value is enclosed as appx A 5 Sch A Part-II (External Water supply)Lump sum price worked out by the contractor for ExternalWater Supply as listed in Schedule A Part-II against the lump sum price inserted by the MES. 6 Sch A Part-III(Road, Path and Culvert)Lump sum price worked out by the contractor for Road Path and Culvert as listed in Schedule A Part-IV against the lump sum price inserted by the MES. 7 Sch A Part-IV(Sewage Disposal)Lump sum price worked out by the contractor for Sewage Disposal as listed in Schedule A Part-V against the lump sum price inserted by the MES. 8 Sch A Part-V(Demolition & Dismantling)Lump sum price worked out by the contractor for Demolition & Dismantling as listed in Schedule A Part-VII against the lump sum priceinserted by the MES. 9 Sch A Part-VI(Site clearance, excavation & earth works)Lump sum price worked out by the contractor for Site clearance, excavation & earth works as listed in Schedule A Part-VII against the lump sum priceinserted by the MES. 10 Note for Srl No 2 to 9The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 9by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 11 Schedule A Part-VII (Miscellaneous works) 12 Sewage Disposal 13 Item No 01 : Soakage wells 1.20 M dia X 3.0 M effective depth, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 40 mm to 63 mm as specified and directed.(Drg No. BTD - 744) 14 Item No 02 : M&L for LDPE septic tank designed to carry sewage and sullage water, with upflow filter incoming media excavation in any type of soil, PCC 1:4:8 below foundation, etc with vent shaftof 10 users complete all as per manufacturer instructions. 15 External Water Supply 16 Item No 03 : Supply, Laying in trenches 150 mm nominal diaductile iron pressure pipe, for water mains centrifugally cast with spigot and socket ends (for push on joints), Class K-9 of standard length 5.5 mtr complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately. 17 Item No 04 : All as per item No 03 here-in-before but 200 mm dia 18 Item No 05 : All as per item No 03 here-in-before but 250 mm dia 19 Item No 06 : M & L for rubber gasket joints (push on joints) for spigot/ socket end ductile iron water mains/ductile iron specials complete for 150 mm nominal dia complete all as specified and as directed. 20 Item No 07 : All as per item No 06 here-in-before but 200mm dia 21 Item No 08 : All as per item No 06 here-in-before but 250mm dia 22 Item No 09 : Supply and fix DI special suitable for DI pipe class K-9 upto 300 mm dia complete all as specified and as directed. 23 Item No 10 : Construction of mesonary valve pit chamber with burnt brick (Sub class B) in cement mortor (1:6) and 10 mm thick plastering in CM1:4 and PCC (1:4:8) type D-2 in foundation bed or size internally climent on 1500 mm x 1500 mm x 1500 mm with 3 mm thick MS sheet cover with locking arrangement hinged with 40 x 40 x 5 mm angle iron frame embeded in PCC (1:3:6) type C-1 etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces completed including earth work all as specified and directed. 24 Manning & Operation for 02 Years During Defect Liability Period: 25 Mate Fitter General Mechanic (FGM) (Semi-skilled) - 02 NO in each shift (total - 06 Nos FGM (Semi-skilled) 03 shifts) 26 Item No 11 : Manning & Operation for 1st year during DLP: Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrsincluding daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 27 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 0600 to 1400 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 28 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 29 Note for ser Item No 11 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 30 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 31 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 32 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 33 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 34 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 35 Item No 12 : Manning & Operation for 2nd year during DLP: Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 36 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 06 : 0600 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 37 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 38 Note for ser Item No 12 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 39 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 40 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 41 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 42 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 43 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 44 Item No 13 : Manning & Operation for 3rd year (To commence from next day of comletion DLP): Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 45 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 06 : 0600 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 46 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 47 Note for ser Item No 13 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 48 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 49 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 50 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 51 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 52 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 53 Item No 14 : Comprehensive maintenance, (To commence from next day Expiry of DLP) servicing and repairs of water treatment plant 600000 gallons alongwith cleaning of spray nozzles of aeration fountion, scrubbing of parshall flume so as to keep the flow surfaces clean of surface buildup or algae growth, deep cleaning the flash mixer by washing the attachment, dewatering the flocculator completely and cleaning its channels and removal of flocs deposit by any means, removal of sludge deposition in clarifier and depositing the sludge at a certain distance so as to avoid contamination to clear water, backwashing of rapid sand filters, cleaning of solution tanks for any deposition, ewatering the UG sump of capacity 2500 gallon and cleaning its interior surface for algae deposition if any, opening the valves and cleaning it and refixing in original state, cleaning of pipeline connetions and fixing the leakages if any all as directed by engineer- in - charge. 54 Item No 15 : Manning & Operation for 4th year (To commence from next day of comletion of item no.-13): Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 55 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 0600 Hours to 1400 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 56 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 57 Note for ser Item No 15 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 58 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 59 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 60 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 61 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 62 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 63 Item No 16 : Comprehensive maintenance, (To commence from next day of comletion of item no -14) servicing and repairs of water treatment plant 600000 gallons alongwith cleaning of spray nozzles of aeration fountion, scrubbing of parshall flume so as to keep the flow surfaces clean of surface buildup or algae growth, deep cleaning the flash mixer by washing the attachment, dewatering the flocculator completely and cleaning its channels and removal of flocs deposit by any means, removal of sludge deposition in clarifier and depositing the sludge at a certain distance so as to avoid contamination to clear water, backwashing of rapid sand filters, cleaning of solution tanks for any deposition, ewatering the UG sump of capacity 2500 gallon and cleaning its interior surface for algae deposition if any, opening the valves and cleaning it and refixing in original state, cleaning of pipeline connetions and fixing the leakages if any all as directed by engineer- in - charge. 64 Item No 17 : Manning & Operation for 5th year (To commence from next day of comletion of item no. 15): Providing services of daily maintenance, manning & operation with fitter general mechanic mate FGM (Semi-skilled) to water supply installation located at 20 Camp Pump House consisting of centrifugal pumps, aeration fountain, floculator, clarifier, rapid sand filter, UG sump of cap 25000 gallon, chlorination system, OHT of cap 100000 gallon round the clock in Three shifts (Morning, Evening & Night), including sundays & holidays each shift of 08 hours starting from 0600 Hrs including daily checking and rectifying leakges and operating the raising, delivery, washout and overflow pipes, valves, pit chambers and operating pumping sets during supply with any minor repair required like replecement of gland, tightening of terminations, inspect motor vents and windings for dust/dirt build-up and clean accordingly, inspect starter/ contractor for arcing, lubricate the pump the motor bearing on regular intervals, oiling and greasing etc of equipments for smooth trouble free functioning all as directed by Engineer-in-Charge. 65 Note: (a) Duty o tradesmen in addition to above is to operate the installation & provide uninterrupted water supply to the stn and report to JE/AGE during breakdown/fault(b) The term Daily Operation includes Minor Maintenance like General Clearing, Cleaning of Machines, Equipments and Hourly Reading, Recording of Each Plant, Log Sheet)s) will be provided by the contractor to all equipments of pump house in standard proforma to make record in consultation with engineer-in-charge. (c) Protective clothing as per IS and safty instructions are to be provided by the contractor and will be continuously in use of the operator on duty. No extra payment shall be made to the contractor for the same (d) SHIFT DUTY (TIMINGS):- (I) MORNING SHIFT : 0600 Hours to 1400 Hours, (ii) Evening Shift : 1400 Hours to 2200 Hours, (iii) Night Shift: 2200 HOurs to 0600 Hours. 66 DETAILS OF WATER SUPPLY INSTALLATION:-(a) Centrifugal pumping sets including connected starter - 02 Nos (b) Aeration fountain(c) Flocculator (d) Clarifier(e) Rapid sand filter (Min 02 Nos)(f) Chlorine dosing plant - 01 No (g) Control electrical panel boards of centrifugal pump sets(h)OHT of cap 100000 gallon 67 Note for ser Item No 17 (i) Operator / Technical / attendent of proper trade with ITI qualified having minimum 04 years of experience in their respective field. (ii) Contractor shall produce all qualification & experience certificates, photos and police verification to all operators / technician before commencement of this contract to engr-in-charge. After verification & satisfaction of engr-in-charge operator/ technician shall deployed to E&M installation. 68 (iii) Replacement of minor parts such as flare nuts, LT cable joints with suitable size lugs, pump glands etc are contractors responsibility complete all as specified by engineer-in-charge.(iv) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duty signed kept on record and payment of trade men for the Nos of days present will only be made GE will responsible for payment of trade men in aadhar linked accountcontractor shall be provide proper dress to tradesmen as approved by Eng-in-charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues. 69 (v) In case the contractor does not operate any one of installation for a day or part thereof due to any reason whatsoever double of the quoted rate to eachday will be recovered.(vi) Leave of deployed person in inescapable cases shall be allowed on prior intimation but contractor on demand of engineer-in-charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.(vii) in no case wages of deployed persons shall be less than the minimum wages fixed by govt competent authority. It is mandatory requirement fdor contractor that payment of deployed person shall be made through cheque/ RTGS/Acceptable Electronic mode only proof of payment shall be submitted by contractor to engineer in charge monthaly basis or during claming on account of advance (RAR) / FB. 70 (viii) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952, shall be strictly adhered to by the contractor, social security to workers i.e. EPF, ESIC, Personal insurance (If applicable) on part of Employer shall be paid by contractor and accordingly, contractor/Bidder shall include all these factors in his quoted rate.(ix) statuatory levies/GST if applicable on part of contracts shall be paid by contractor and accordingly, contractor/ Bidder shall include all these factors in his quoted rate.(x) Deployed person shall report daily to JE/Engineer in charge or nominated officers by Accepting officer for their attendence & obtain instructions. An attendence register shall be maintained by contractor on site. 71 (xi) T&P = working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by contractor at his own cost.(xii) An uniform of blue shirt/jersy duly embossed MES OUTSOURCING SERVICES at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.(xiii) Documentation - Attendance registr & wages register, Daily work register as per the format provided by the Deptt. shall be prepared & maintained at his own cost. 72 (xiv) Contractor shall make security pass for all operators and maintain proper register duly signed by all concerned.(xv) If quoted rates are less than minium fair wages inclusive of GST, EPF, ESIC as applicable the bid shall be treated as non-bonafide and will be rejected. No objection/clain in this regard will be accepted (xvi) Scope of work shall include physical chemical and bacteriological analysis of water, samples to be collected each month by a rep of contractor and carefully taking the sample to Test Laboratory and handing over the sample and collection of test report in stipulated time period and submitting the repost to this office every month. 73 Item No 18 : Comprehensive maintenance, servicing and repairs of water treatment plant 600000 gallons alongwith cleaning of spray nozzles of aeration fountion, scrubbing of parshall flume so as to keep the flow surfaces clean of surface buildup or algae growth, deep cleaning the flash mixer by washing the attachment, dewatering the flocculator completely and cleaning its channels and removal of flocs deposit by any means, removal of sludge deposition in clarifier and depositing the sludge at a certain distance so as to avoid contamination to clear water, backwashing of rapid sand filters, cleaning of solution tanks for any deposition, ewatering the UG sump of capacity 2500 gallon and cleaning its interior surface for algae deposition if any, opening the valves and cleaning it and refixing in original state, cleaning of pipeline connetions and fixing the leakages if any all as directed by engineer- in - charge. 74 Item No 19 : RCC hume pipe NP-2 1500 mm dia laid over 100 mm thick PCC type B-1, 1:2:4 over 100 mm thick PCC type E2 1:5:10, vertically. The top cover of valve pit chamber shall be covered with MS sheet 1.25 mm thick with MS Angle iron 40 x 40x 6 mm thick frame and MS angle iron 30 x 30 x 6 mm thick for shutter frame & flat iron 40 x 6 mm bracing with M.S. sheet. All MS item shall be painted with two coat o synthetic enamel paint over a coat of red oxide primer. 75 Item No 20 : MS pipe 40 mm dia (medium grade) @ 1.0 m spacing and 850 mm long) and MS pipe 25 mm dia (Medium grade) - 3 Row duly painted provided to coat of synthetic enamel paint over coat a red oxide primer, railing to be provided to every items/ Part of water treatment plant. 76 SCHEDULE A(Schedule of credit)Schedule of Credit Rs 994845.00 (Minus) inserted by the MES.(Note : Credit amount shall be deducted manually to arrive net bid amount)
Contract Date: Oct 31, 2025 Contract Value : 5.41 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
33.
Defence #8177176 AOC
Tender For Provn Of Stp At Af Stn Bihta; 1 SCHEDULE A PART I (BUILDING WORKS) 2 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartI . 3 SCHEDULE A PART II (INTERNAL WATER SUPPLY) 4 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartII. 5 SCHEDULE A PART III (INTERNAL ELECTRIFICATIONS) 6 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartIII. 7 SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) 8 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartIV . 9 SCHEDULE A PART V (EXTERNAL ELECTRIFICATION) 10 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartV 11 SCHEDULE A PART VI (SEWAGE DISPOSAL) 12 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartVI 13 SCHEDULE A PART VII (AREA DRAINAGE) 14 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartVII 15 SCHEDULE A PART- VIII (ROAD/PATH AND CULVERT) 16 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartVIII 17 SCHEDULE A PART- IX (COMPOUND WALL, FENCING AND GATE) 18 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part IX 19 SCHEDULE A PART- X (EARTHWORK AND SITE CLEARANCE) 20 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part X 21 Sch A PartXI (Miscellaneous Items of B/R and E/M) 22 Design, supply, installation, testing and commissioning of sewage treatment plant (STP) fully automatic alongwith SCADA (without sample analyser) of STP following capacity with following specifications :- 23 Sewage treatment plant (STP) having capacity of 200 cum/day (KLD) at AF Stn Bihta including all civil work electrical, mechanical, control and instrumentation works alongwith provn ofrequired LT panel, pump as based on latest CPCB norms & rating for STP and other allied equipment for STP as per OEM to achieve the parameter as mentioned in tender documents. Parameters for treated water are encl. Parameters of Raw sewage as given in Annexure- I are tentative however contractor should test the raw sewage at their endfrom any auth Govt lab (NABL accredited) and STP should be designed accordingly to discharge treated water as per parameters specified in tender documentsNotes :-(i) There is no embargo on the technology to be used for sewage treatment scheme. Any technology selected for STP should also take accountability of the expertise in the area, Life cycle cost of the STP and intended reuse of treated waste water STP shall be provided as per parameters as per Annexure.(ii) Bidder will submit detailed drg/design/hydraulic diagram/tech data duly vetted by IIT/NIT to GE (AF) Bihta for approval of scheme/drg by CWE(AF) Bamrauli.(iii) Scope of work include complete civil, electrial and mechanical work alongwith treated water tank of detention time 4 hours, mechanical and electric work pertaining to STP plant including Raw sewage collection sump suitable for 200 KLD capacity plant. The scope also includes LT Panel for STP. Panel should have incoming/outgoing MCCB and other protective/ operational devices as to be designed by contractor/OEM/consultant for operation of the plant. 24 (iv) Contractor will keep a stock of spares as required to changed periodically as per OEM. The spare parts required to changed should be easily available in market and no foreign spares to be used in the STP.(v) In case bidder select MBBR technology then equilization tank of suitable capacity to be provided at site. 25 The rate for manning portion will be measured and paid seperatly under respective item. Rates quoted by the contractor shall also be inclusive for following items :-(i)Contractor shall provide all type of tool kits as required for maintenance of STP installation.(ii)Minor stores required for maintenance should be provided by the contractor as directed by Engr-in-Charge.(iii)Contractor shall provide process and line diagram of STP plant on SS Board of size 4 feet 3 feet including capacity and specification of STP. 26 Lifting Man hole Pump :- Design, Supply, installation, testing and commissioning of vertical non-clogging type wet pit application pump suspended by vertical column pipe which protect the transmission shaft. Pumps having solid handling capacity of upto 30 mm size particles having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control, etc. including suitable size of submersible cable from control to motor panel complete all as specified and directed by engineer-in-charge for following requirement sizes:- Make: CRI, Grundfos, Kirloskar, Wilo, XylemNOTE :-The qtymentioed are tentative and can be varried as per the design submitted by the bidder. 27 4.67 m3/hr discharge at 10 MWC, (1 W +1S), Peak Flow 28 1.17 m3/hr discharge at 10 MWC (1W +0S), Avg Flow 29 5.53m3/hr discharge at 10 MWC(1W +1S), Peak Flow 30 1.38 m3/hr discharge at 10 MWC(1 W +0S), Avg Flow 31 9.43 m3/hr discharge at 10 MWC (1 W +1S), Peak Flow 32 2.36 m3/hr discharge at 10 MWC, (1 W +0 S), Avg Flow 33 INTERMEDIATE SUMP 1&2 :- Design, Supply, installation, testing and commissioning (SITC) of vertical non-clogging type wet pit application pump suspended by vertical column pipe which protect the transmission shaft. Pumps having solid handling capacity of upto 30 mm size particles having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control, etc. including suitable size of submercible cable from control to motor panel complete all as specified and directed by engineer-in-charge. required for following intermideate sumps :-Make: CRI, Grundfos, Kirloskar, Wilo, Xylem.NOTE :-The qtymentioed are tentative and can be varried as per the design submitted by the bidder. 34 15.22 m3/hr discharge at 10 MWC (1W +1S), Peak Flow INTERMIDEATE SUMP -1 35 3.81 m3/hr discharge at 10 MWC (1W +0S), Avg Flow INTERMIDIATE SUMP-1 36 25.88 m3/hr discharge at 10 MWC (1W +1S), Peak Flow INTERMIDEATE SUMP-2 37 6.47 m3/hr discharge at 10 MWC (1W +0S), Avg Flow INTERMIDATE SUMP-2 38 Material & labour of ductile iron pressure pipes having K-9 class, 100 mm Nominal bore, conforming to IS 8329: 2000,having socket & spigot end with necessary fitting i.e. tee,bend,socket etc. including pipe specials complete all as specified and directed by engineer-in-charge. 39 M & L for sludge transfer 50 mm Nominal bore,MS ERW CLASS- C Piping of including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories, duly insulatedcomplete all as specified and directed by the engineer-in-charge. 40 M & L for sludge transfer 80 mm Nominal bore,MS ERW CLASS- C Piping of including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories, duly insulatedcomplete all as specified and directed by the engineer-in-charge. 41 M & L for sludge transfer 100 mm Nominal bore,MS ERW CLASS- C Piping of including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories, duly insulatedcomplete all as specified and directed by the engineer-in-charge. 42 Supply, installation, testing and commissioning of50 mm nominal bore wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 43 Supply, installation, testing and commissioning of80 mm nominal bore wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 44 Supply, installation, testing and commissioning of100 mm nominal bore wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 45 Supply, installation, testing and commissioning of 50 mm nominal bore wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 46 Supply, installation, testing and commissioning of 80 mm nominal bore wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 47 Supply, installation, testing and commissioning of 100 mm nominal bore wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulatedcomplete all as specified and directed by the engineer-in-charge. Make: Sant, Hindustan, Advance 48 S & F of 4 bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories, etc. as specified and directed by engineer-in-charge.Make: General, WIKA, TSI 49 Supply, installation, testing and commissioning of CPRI approved load-break/fault-make switch with TAG type HT HRC fuse, fuse trip mechanism, earth switch with interlock with the main drive mechanism, shunt trip coil (220 V, 50 Hz, AC) and electrical standard indications, conforming to IS 9920/ IEC 62271-2002 and having the following specifications for outdoor floor mounted installation including plateform as per manufacturer recommendation as specified and directed by the engineer-in-charge. 50 [i] Type of Break: Air Break 51 [ii] Rated Voltage: 12 kV 52 [iii] Rated Frequency: 50 Hz 53 [iv] Rated Current: 630 A 54 [v] Rated Peak Current: 85 kA 55 [vi] Rated Short time Current: 31.5 kA (for 1 sec.) 56 [vii] Rated Making Current: 80 kA 57 [viii] Rated breaking Current: 630 A 58 [ix] Impulse Voltage wave shape 1.2/50 µs: To Earth: 75 kV; Between Poles: 75 kV; Between Open Contacts: 85 kV 59 [x] Power Frequency Test Voltage: To Earth: 35 kV; Between Poles: 35 kV; Between Open Contacts: 45 kV 60 [xi] Breaking of Capacitive Load: 50 A 61 [xiii] Closed Loop Breaking Current cos φ = 0.31 MD 62 [xiv] Rated Transformer Off Load Breaking Capacity = 120 A 63 [xv] Rated Line Charging Breaking Capacity: 90 A 64 [xvi] No. of Poles: 3 65 [xvii] No. of Breaks per Pole: Single 66 [xviii] Degree of Protection: IP 65 67 S & F 45W LED street-light having pressure die-cast housing with toughned glass and individual LEDs with secondary optics and IP 66 protection, including necessary electrical connections to the fitting with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer all as specified and directed. [Make: BAJAJ Cat-Part No. 169799 BRTFG 45W LED ,Havelles Cat-Part No. ENDURAPEARLNEOSL45WLED757PASYTOPC, Crompton Cat-Part No. LSTP-45-CDLor equivalent] 68 S & F weather- proof PVC junction box of size 250 mm x 200 mm x 100 mm, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos. of polymide gland with check nut (M-32- 3 Nos.) fixed on poles with flat aluminium clamps of size 20 mm x 3 mm, nuts, bolts, washers, etc. complete all as specified and as directed. [Make: SINTEX Cat-Part No. GS-JB-2817, ENYCASE Cat-Part No. KF5350, HENSEL Cat-Part No. JSN250 or equivalent] 69 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based (LIFTING MANHOLE - 27 Panel) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( LIFTING MANHOLE - 27 Panel) 70 The Panel shall comprise of the following: 71 [a] Busbar Chamber: 72 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 73 [a] Incoming: 74 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 75 Programmable Logic Controller (PLC) Feeder 76 PLC Unit - 01 No. with Power Supply Unit 77 [b] Outgoing: 78 [i] 0.5 HP Starter with 1.6A, 100kA, TM Release MPCB - 2 No. 79 [ii] 0.2 HP Starter with 1A, 100kA, TM Release MPCB - 1 No. 80 Ultrasonic Sensor - 03 Nos. 81 Panel Enclosure 82 Size :- 600MM (W) x 700MM (H) x 300MM (D) 83 Fabrication:- 3.15 mm CRCA sheet 84 Pre Treatment : 7 tank process 85 Painting : Powder coated with RAL7032 86 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based LIFTING MANHOLE - 123 Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( LIFTING MANHOLE - 123 Panel) 87 The Panel shall comprise of the following: 88 [a] Busbar Chamber: 89 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 90 [a] Incoming: 91 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 92 Programmable Logic Controller (PLC) Feeder 93 PLC Unit - 01 No. with Power Supply Unit 94 [b] Outgoing: 95 [i] 1 HP Starter with 2.5A, 100kA, TM Release MPCB - 2 No. 96 [ii] 0.2 HP Starter with 1A, 100kA, TM Release MPCB - 1 No. 97 Ultrasonic Sensor - 03 Nos. 98 Panel Enclosure 99 Size :- 600MM (W) x 700MM (H) x 300MM (D) 100 Fabrication:- 3.15 mm CRCA sheet 101 Pre Treatment : 7 tank process 102 Painting : Powder coated with RAL7032 103 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based LIFTING MANHOLE - 88 Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( LIFTING MANHOLE - 88 Panel) 104 The Panel shall comprise of the following: 105 [a] Busbar Chamber: 106 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 107 [a] Incoming: 108 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 109 Programmable Logic Controller (PLC) Feeder 110 PLC Unit - 01 No. with Power Supply Unit 111 [b] Outgoing: 112 [i] 1 HP Starter with 2.5A, 100kA, TM Release MPCB - 2 No. 113 [ii] 0.2 HP Starter with 1A, 100kA, TM Release MPCB - 1 No. 114 Ultrasonic Sensor - 03 Nos. 115 Panel Enclosure 116 Size :- 600MM (W) x 700MM (H) x 300MM (D) 117 Fabrication:- 3.15 mm CRCA sheet 118 Pre Treatment : 7 tank process 119 Painting : Powder coated with RAL7032 120 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based INTERMEDIATE SUMP-1 Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( INTERMEDIATE SUMP-1 Panel) 121 The Panel shall comprise of the following: 122 [a] Busbar Chamber: 123 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 124 [a] Incoming: 125 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 126 Programmable Logic Controller (PLC) Feeder 127 PLC Unit - 01 No. with Power Supply Unit 128 [b] Outgoing: 129 [i] 2 HP Starter with 4A, 100kA, TM Release MPCB - 2 No. 130 [ii] 0.5 HP Starter with 1.6A, 100kA, TM Release MPCB - 1 No. 131 Ultrasonic Sensor - 03 Nos. 132 Panel Enclosure 133 Size :- 600MM (W) x 700MM (H) x 300MM (D) 134 Fabrication:- 3.15 mm CRCA sheet 135 Pre Treatment : 7 tank process 136 Painting : Powder coated with RAL7032 137 Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical type PLC based INTERMEDIATE SUMP-2 Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 55 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. ( INTERMEDIATE SUMP-2 Panel) 138 The Panel shall comprise of the following: 139 [a] Busbar Chamber: 140 [i] Aluminium busbar of 80A capacity, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3P + N) 141 [a] Incoming: 142 [i] 16 A, 415 V, Ics = Icu =10 kA, 50 Hz, FP MCB - 01 Nos. 143 Programmable Logic Controller (PLC) Feeder 144 PLC Unit - 01 No. with Power Supply Unit 145 [b] Outgoing: 146 [i] 3 HP Starter with 6.3A, 100kA, TM Release MPCB - 2 No. 147 [ii] 1 HP Starter with 2.5A, 100kA, TM Release MPCB - 1 No. 148 Ultrasonic Sensor - 03 Nos. 149 Panel Enclosure 150 Size :- 600MM (W) x 700MM (H) x 300MM (D) 151 Fabrication:- 3.15 mm CRCA sheet 152 Pre Treatment : 7 tank process 153 Painting : Powder coated with RAL7032 154 S & F ISI marked 16 A, SP, C- curve MCB for AC applications till following capacity, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed. Make: Schneider, Legrand, Havells 155 Design, Engineering, Supply, Install, Testing and Commissioning ofsilent Diesel engine driven Generating set of minimum capacity50 KVA, 415 Volts, 3 Ph, 4 wire, 50 Hz engine as per IS:10002 and alternator as per IS:13364 complete with relay panel and switchgears for automatic starting on mains failure, control panel and sound proof canopy as per CPCB norms, necessary earthing pits, connections and foundation, platform all as per manufacturer recommendations,etc all as specified and directed.Make:Kirloskar, Crompton Greves, Cummins or other make approved by GE 156 DG set should be CPCB–IV norms complaint. Emission limit (g/kW-hr) standard shall be as under:- 157 The DG Set & AMF Panel shall be wired, interlinked & logically controlled with commercial supply for uninterrupted supply to the Essential Services LT Panel. 158 S & F 10 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: BAJAJ Cat-Part No. 112407 BCLSB 10 WH or equivalent model of Havells, Philips or Wipro 159 S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.Make: BAJAJ Cat-Part No. 112785 BCLAB 20W or equivalent model of Havells, Philips or Wipro 160 S & F 20 W LED buildingsecurity light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 100 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Copper conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed. Make: BAJAJ Cat-Part No. BAJAJ 169799 BRTFG 45W LED I or equivalent model of Havells, Philips or Wipro 161 S & F BLDC five star rated energy efficient high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. Make: Crompton Cat-Part No. ENTRUST50 or Havells Cat- Part No. ES-50 or equivalent model of Usha or BAJAJ 162 S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10 or equivalent model of Usha, Havells or BAJAJ 163 S & F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 6000 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No.EXHD450- 4-1 or equivalent model of Usha, Havells or BAJAJ 164 S & F ISI marked MCB for AC applications 6 A SP C Curve type, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed. 165 S & F ISI marked MCB for AC applications 63 Amp DP C Curve type, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed. 166 Supply and laying SFRC Manhole cover complete all asspecified 167 S & F 150mm Wide PVC Water Bar complete all as specified and directed. 168 M & L for providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 7 conforming to IS : 8329 : 100 mm dia Ductile Iron Double Flanged 169 M & L for Cutting of PQC/PCC road to the width and depth required for laying RCC NP3 pipe of sewage line including hacking banching and including making good to top surface of road width 170 M & L for Cutting of bituminous road to the width and depth required for laying RCC NP3 pipe of sewage line including hacking banching and including making good to top surface of road width 171 Supply and fix chain pulley block capacity 02 ton with tripod mannual type including suitable size of MS chain for lowering and lifting complete all specified and directed 172 M & L for cutting holes in RCC walls exceeding 150 mm thick and not exceeding 230 mm thick making joints for drain pipes including making good the cutting surface using cement concrete (using 12.5 mm graded stone aggregate), complete all as specified and directed by Engineer - in - Charge. 173 Supply, installation, testing and commissioning of Submersible treated water pump capable of100 m3/hr discharge at 30 MWC head having CI casing & impeller complete with all accessories, motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply, pressure gauge with isolation cock, isolation valve, NRV on delivery line, strainer at suction. mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve, etc. complete all as specified and directed by engineer-in-charge. (1 W+ 1 S) 174 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 175 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 176 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 177 NOTE FOR ITEM NO 164to 166:-THE QUOTED RATE SHALL BE DEEMED TO INCLUDED THE FOLLOWING OPERATIONS :-(a) These item shall be executed during the defect liability period of 24 months after completion of Phase I, contractor shall quoted the rate accordingly.(b) All consumable items as well as parts such as Sodium Hypo chlorite and any other chemical required, compressor oil, grease etc required for operation of plant shall be provided by contractor at his own cost as per the manufacturers instructions and direction of GE during the period of Manning & Operation. Cost of the same shall be deemed included in the unit rates quoted by contractor as overed onder defect liability period. 178 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 179 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 180 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 181 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 182 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 183 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 184 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 185 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 186 Manning and operation of Sewage Treatment Plant of capacity 200KLD and testing lab cum control room alongwith STP associated connected accessories at AF Stn Bhita installed under this CA for a period of 11 months to keep installation in functionalcondition in three shifts per day of 08 hrs each( Ist shift from 0600 hrs to 1400 hrs, IInd shift from 1401 hrs to 2200 hrs, III shift from 2201 hrs to 0600 hrs) including maintainig log sheet and other periodical maintenance record complete all as specified and directed by qualified staff for :- (a) 01 No skilled operators (FGM) and 01 No helper (Mazdoor) for all three shift per day required for whole month 187 NOTE FOR ITEM NO 168 to 176 :- (a) These item shall be executed after the defect liability period of 24 months after completion of Phase II, contractor shall quoted the rate accordingly.(b) All consumable items as well as parts required for M & O afterthe defect liability period shall be issued by the department as free for fixing.(c) The contractor shall enter in to MOU with OEMs for the provision of STP plant and further for M &O (During the defect liability period and after the defect liability period as catered in tender and the same shall be submitted by the bidder before issue of completion of phase I.(d) THE QUOTED RATE SHALL BE DEEMED TO INCLUDED THE FOLLOWING OPERATIONS :- 188 (i) Preventive and breakdown maintenance of all the equipments by regular oiling greasing chaging of gland packing, replacement of nuts and bolts etc during th eperiod of work order.(iii) To maintain the instalaltions provided under this contract as per PCB norms/standard Engineering pratice.(iv) Sapre parts if any required for operation/amintenance of sewage treatment plant during the currency of defect liability period shall not be included in the rate quoted.(v) Periodiocal maintancence shall be carried out by the authorised representative of the original equipment manufacturer(OEM) 189 (vi) Electric and water for operation of the plant will be supplied by the department free of cost.(vii) Operation of raw sewage pump, air blowers, filler feed pump, dual media filter activate carbon filter(if applcable), dosing sysyem, ultra filtration system(if appilcable)& control panel.(viii)Removing of material arrested at bar screeen.(ix) Removing of oil floating at surface.(x) Change over from one pump to another daily on requirment.(xi) Change over from one blower to another blower on requirment.(xii) Cleaining of air filter of blower regularly on requirment basis. 190 (xiii)Applying grease to all motors blowers periodically including supplying of suitable quality of grease as per site requirement. (xiv) Draining of sludge from MBBR reactor once in a month to avoid chocking of air guard. (xv)Removing of sludge from settler depending upon the actual load. (xvi)Maintaining of log books for records operation of plants including cost of stationary. (xvii) Back wash offilter and activate carbon filter weekly. (xviii)Screeing of inlet and outlet mesh boxreactor weekly.(xix) Washing to tube media with low pressure out of raw water required. (xx)Draining of burn out lubricant oil and refilling of appropriate lubricate oil in air blower after 2000-2500 operation including cost of lubricant. (xxi) Maintenance and operation of filter press and collection output neatly / A-05/P-165.(xxii) STP operation of standby DG set and when required.(xxiii)STP operating clear water pumps regularly and in consultation with Engineer-in-Charge.(xxiv) Oteh maintenance work as per instruction of Engineer - in - Charge. 191 NOTE FOR ITEM NO 164 TO 176 :- Contractors quoted rates for the above items shall be deemed to include the cost of following also :-(a)Testing of treated water :The treated water shall be got tested by the tenderer once in a month from regional Govt Lab / other approved lab.Samples shall be collected in the presence of Engr-in-Charge and test reports shall be submitted to Engr-in-Charge in original for record purpose.If parameters of tested water are beyond the limits mentioned in PS or Contractor failed to carryout the required tests the recovery at double the quoted rates of the Contractor for the entire month for M & O shall be made from the Contractor. (b) Maintain the safety and security measures of the palnt. (c)Keep the installation neat and tidy. (d)Decision of GE shall be final and binding on account of quality and quantity of material/ chemicals required for maintenance and operation of the plant.All materials brought at site and incorporated in work during the defect liability period shall b ekept in record purpose duly indicated with relevant purchase vouchers and test certificates. (e) Disposal of treated sewage/sludge as directed by Engr-in-Charge.(f) Efficient treatment of the sewage water shall be ensured by the Contractor and required characterstics of outlet treated sewage shall be as specified in PS.(g) The contractor shall be responsible for watch and guard of installations round the clock 24 hours. Any loss or damage to the plant, uipmen tinstalled and Govt. property in the Pump house premises shall be made good/borne by e contractor. (h) Operating connected accessoriess such as all type of sluice valve & connecting accessories shall be deemed included in the unit rates quoted by contractor. 192 (j) Testing of earthing of machinary/equipment shall be carried out on monthly basis as directed.(k) If any loss or damage takes place to the equipment, machinery, tools, stores, fitting and fixtures etc or any other equipment installed in the pump house premises during the contract period, the same shall be made good/borne by the contractor. (l) The contractor will submit the complete details of the tradesmen alongwith their ualification certificate before commencement of work. (m) General cleanliness and upkeeping the existing pump house including getation within the primises of pump houses/sumps are aupto 5 Mtrs all round within the and ary walls by deploying manpower with T&P if required, at any time all as directed.(n) Please ensure that all trademen engaged in subject work covered in EPF scheme. Proper doc should be maintained in this regard and submitted alongwith each payment.(o) The expense incurred due to insurance and EPF scheme for the staff deployed by the contractor for manning & operation shall also be deemed included in the quoted rates of BoQ. Nothing extra shall be admissible in this account. (p) Contractors quoted rates hall be deemed to include removal of dried sludge and its disposal outside MD land during the M&O period as directed by Engineer-in-Charge. (q) Testing of incoming sewage and treated sewage shall be done by the contractor from any Govt. approved lab as approved by GE on a monthly basis during the M & Operation test report shall be submitted to GE.Contractors quoted rate shall be deemed to include for the same 193 (r) In case contractor fails to employ the duty person in any of the shift, he shall be liable to be the recovery @ Rs 1000/-per shift and No payment shall be made for that shift. (s) If any loss or damage takes place to the equipment, machinery, tools, stores, fitting and fixtures etc or any other equipment installed in the pump house premises during the contract period, the same shall be made good/borne by the contractor. (t) The contractor will submit the complete details of the tradesmen alongwith their ualification certificate before commencement of work. (u) Unit rates inserted are inclusive of minimum wages as per latest notifications, Labour Welfare Cess @1% and GST @ 18%. (v) The items required for comprehensive maintenance after DLP shall be supplied by the department by the concern GE as per requirement. 194 (vi)Contractor shall provide all type of tool kits as required for maintenance of STP installation.(vii)Contractorshall provide two set of uniform with name plate and one mobile set duly recharged of each operator & helper .(viii)The log sheets will be maintained by the operator in installations & contractor shall provided Log Book, Attendance register, Plant running record book and rate quoted by the contractor shall deemed to included in his quoted rates.(ix)The contractor will be responsible for upkeep of the installation in neat and tidy conditions and in a presentable manner. The surrounding of the installation will also be maintained neat and clean by removing grassesand other vegetation.(x)Greasing, lubricating of all equipment of installation including cleaning of screen bar, oil grease trap as directed by Engr-in-Charge.(xi)The site documents such as log sheet, Attendance etc will be checked by daily by JE, weekly by Engr-in-Charg and monthly by GE.(xii)Technical qualification of operator in ITI Pass in electric/Engine fitter from Govt institution with 3 years experience in related trade .(xiii)Minor stores required for maintenance should be provided by the contractor as directed by Engr-in-Charge. 195 (xiv)Contractor shall submit all documents within one month such insurance cover, EPF, ESI, Police verification of all the workers employed by him.(xv)Testing of earthing of each equipment and record will be produce to Engr-in-Charge in each 6 months, testing equipment will be provide by contractor. Watering with salt in each earthing for obtaining the result less than 1 ohms.(xvi)Operator will be working at site all safety precaution, in case my accident/injury of any person deputed by contractor shall be fully responsible for setting all claims/compensation.(xvii)The chemicals required for treatment /disinfection of water will be provided by the contractor. Water treatment/disinfection shall be done timely and quality of water will be checked as per IS specification before supplying to users. Penalty will be imposed to contractor in absence of chemical dozing Rs 200/day.(xviii)If any slackness noticed a suitable action shall be initiated as per the existing rule and contract is liable to be terminated.(xix)Contractor will employee addition employee for rest/leave.(xvi)Proper handing/taking over of operator to be done and operator should not leave the installation before arrival of next operator. 196 S & F of20 mm Nominal bore CL 150 # rated ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories complete all as specified and directed.
Contract Date: Oct 30, 2025 Contract Value : 8.99 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
34.
Defence #8177160 AOC
Tender For Addn/Altn To Toilets In Tech Area For Agniveervayu (Women) At Af Stn Jodhpur; 1 Demolition of cement concrete in ground floors annd paving not exc 15 cm thickness (below or above ground ) and disposing of debris outside MD Land complete all as specified and as directed. 2 Dismantling floor ,hearth or wall tiling inclunding cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 3 Taking down chowkts or frames with shhutter (without taking off shutters from the frame) exceeding 1.5 Sqm not exc 4 Sqm each complete all as specified and as diected. 4 Taking down chowkts or frames with shhutter ( without taking off shutters from the frame ) not exceeding 1.5 Sqmeach complete all as specified and as diected. 5 Taking down shutters of any description area exc. 1 Sqm complete all aas specified and directed. 6 Resecuring or easing & adjusting without taking down of shutters of any description area exc 2 Sqm complete all as specified and directed. 7 Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortor all as directed. 8 Taking downcement or cement lime plaster work any description from brick or stone wall/ ceiling etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified & directed by the Engineer-in-Charge. 9 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. 10 M&L PCC (1:4:8) type D2(40 mm graded stone aggregate) for footing & plinth beam complete all as specified and directed. 11 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft to loose soil complete all as specified and directed. 12 Removing excavated soil not exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 13 M&L for RCC- 1:2:4 type B1 (20mm graded stone aggregate) nominal mixin foundation, plinth beam, including rafts as mass concrete complete all as specified and directed. 14 M&L for form workfor rough finished surfaces of concrete measured flat for foundation & plinth beam complete all as specified and directed. 15 M&L for RCC- 1:2:4 type B1 (20mm graded stone aggregate) nominal mixin columns, piers, posts and struts complete all as specified and directed. 16 M&L for form workfor rough finished surfaces of concrete measured flat for columns complete all as specifed and directed. 17 M&L for RCC 1:2:4 type B1 (20 mm graded stone aggregate ) nominal mix in chajjas complete all as specified and directed. 18 M&L for form workfor rough finished surfaces of concrete measured flat for chajja complete all as specified and directed. 19 M&L for RCC 1:2:4 type B1 (20 mm graded stone aggregate ) nominal mix in beams, cantilevers, bresummers, lintel over 1.5 m span complete all as specified and directed. 20 M&L for form workfor rough finished surfaces of concrete measured flat for GF slab beam, lintel,cantilevers complete all as specified and directed. 21 M&L for RCC 1:2:4 type B1 (20 mm graded stone aggregate ) nominal mix in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all specified and directed. 22 M&L for form workfor rough finished surfaces of concrete measured flat for slab complete all specified and directed. 23 M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 24 M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 25 M&L for precast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar CM (1:4) type C1 (1:3:6) (20mm graded aggregate ) complete all as specified and directed. 26 M&L for precast cement concrete solid building blocks or slabs,10 cm thick (with plain or interlocking joints as directed) setting in mortar, complete all as specified and directed. 27 M&Lfor 10 mm thick 1:6 CM internal plaster on fair faces of walls finished even and smooth (without using extra lime or cement) complete all as specified and directed. 28 M&L for 5 mm thick 1:3 CM plaster on ceiling, finished even and smooth (without using extra lime or cement) complete all as specified and directed. 29 M&L for 15 mm thick (10 mm + 5 mm) in 1:4 CM external plaster on fair faces of walls finished even and smooth (without using extra lime or cement) complete all as specified and directed. 30 M&L for applying two coats of oil bound distemper over a coat of wall primer complete all as specified and directed. 31 M&L for three coats of white wash in ceiling complete all as specified and directed. 32 M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. 33 M&L for non - skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. 34 M&L for vitrified ceramic tiles 10mm thick (square/rectangular) area of each tileexceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed by Engr-in-Charge. 35 Material & labour for vitrified ceramic tiles 10mm thick (square/rectangular) area of each tileexceeding 0.36 sqm but not exceeding 0.42 sqm, as in skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement mortar (1:4) complete all as specified and as directed. 36 M&L for cement concrete 25mm thick 1:2:4 type B0 (20mm graded stone aggregate) as inbase complete all as specified and as directed. 37 M&L for cement concrete 75mm thick 1:4:8 type D2 (40mm graded stone aggregate) as in sub base complete all as specified and as directed. 38 M&L for Glazed Ceramic Tiles In Vertical Surface 350X 250X 7 Mm/ 450X 350X 7Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match & rendering 10 mm thick in CM (1:4) complete all as specified and as directed. 39 M&L for 75mm thick plinth protection PCC (1:3:6) using 20mm graded stone aggregate (0.90m wide) complete all as specified and as directed. 40 M&L for hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed. 41 Demolition of cement concrete of any type description and in any position and dremoving debris ouside MD land complete all as specified and directed. 42 M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed. 43 M&L for brushing neat cement slurry with 3kg of cement per Sqm complete all as specified and directed. 44 M&L for 40 mm thick cement concrete 1:2:4type B0 (12.5 mm graded stone aggregate) in padding finishing surface of concrete topping even and smooth without using extra cement complete all as specified and directed. 45 M&L for 10mm thick plastering in cm 1:3 on green concrete roof surfaces with water proofing compound @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed.Note :- WPC shall be measured and paid separately. 46 Supply only integral water proofing compound ISI Marked complete all as specified and directed. 47 M&L for applying APP modified membrane (minimum 3 mmthick), it shall be taken upto height of minimum 300mm and shall be inserted inside a groove cut in the parapet and fixed. If the height of parapet is 300mm or less, membrane shall be taken till top of the parapet and finished after covering the top surface to the parapet. For RCC inverted beam the whole beam shall be covered with membrane irrespective of the depth. In case of roof projection, the membrane shall be taken 50mm on the reverse side of roof at the edges.with non-woven polyster reinforcement/mat (centre core) with thermal insulation with white mineral gravel finish on upper side of membrane laid by torch application method with overlaps 75mm on length side and 100 mm on the width side as per manufacturer’s instructions over a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 250 gm/sqm complete all as specified and as directed by Engineer-in-Charge. 48 S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reiforced with MS square tube, suppling & fixing in opening as per specification & drawing and as directed. 49 S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm wood grain printed PVC sheet reiforced with MS square tube, suppling & fixing in opening as per specification & drawing. 50 S&F factory made solid panel PVC door shutters 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap inserted for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and as directed. 51 S&F Factory made solid panel PVC door shutters 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side & as gap inserted for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing and as directed. 52 Supply & fixing approved colour powder coated(minimum thickness of powder coating 50 micron) aluminium frame for doors, window, ventilator with one or more rebates or aluminum section of two or more tracks incase sliding windows including jointing cleat for fixing complete all as specified & directed by the Engineer-in-Charge. 53 Supply & fixing approved colour powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. 54 S&F 5.5mm thick sheet glass light colour selected quality fixed in door / window shutter cut to required size and fixed with neoprane gasket, area exceeding 0.50 Sqm in each pane area and solar control film reflective type sticked to glass panes as per manufacturers instructions complete all as specified & directed by Engineer-in-charge. 55 Supply & fixing stainless steel barrel tower bolt of size 150mmfixed in positions complete all as specified & directed by the Engineer-in-Charge. 56 Supply & fixing 125mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and as directed. 57 Supply & fixingstainless steel handlesof size 125mm, complete all as specified and directed. 58 Supply & fixing 300 mm long stainless steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheetcomplete allas specified and directed. 59 Taking up or down steel tubing of 15 mm bore pipe and connection including cleaning for re-fixing or removal to storecomplete all as specified & directed by the Engineer-in-Charge. 60 Taking up or down steel tubing of 20 mm bore pipe and connection including cleaning for re-fixing or removal to storecomplete all as specified & directed by the Engineer-in-Charge. 61 Supply & fixing 15 mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor complete all as specified & directed by the Engineer-in-Charge. 62 Supply & fixing 20 mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor complete all as specified & directed by the Engineer-in-Charge. 63 Supply & fixing in repairs CP Bib taps, fancy type, 15 mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engr-in-Charge. 64 Supply and fixing in repairs two waybrass chromium platedfancy type bib cock 15mm bore complete all as specified and directed. 65 Supply and fixing in repairs 15 mm bore fancy type brass chromium plated telescopic wall mixer for mixing hot and cold water screwed down for iron pipe complete all as specified and directed. 66 Supply and fixing in repairs 15 mm bore center hole basin mixer brass, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks & fly nuts for iron pipe complete all as specified and directed. 67 Supply and fixing in repairs of fancy typepillar taps brass, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks & fly nuts for iron pipe of 15mm bore complete all as specified and directed. 68 Supply and fixing in repairsofbrass chromium plated fancy type soap dish complete all as specified and directed. 69 Supply and fixing in repairs 15 mm bore fancy typeoverhead shower with arm swivel joint chromium plated screwed down of size 200 mm x 200 mm complete all as specified and directed. 70 Supply and fixing in repairsofbrass chromium plated angle stop valves of 15mm bore screwed for 15mm bore iron pipe or union complete all as specified and directed. 71 Supply and fixing in repairstublar towel rail 20mm dia chromium plated brass of size 60cm long complete all as specified and directed by the Engineer-in-charge. 72 Supply and fixing in repairsofbrass chromium plated fancy type towel rack(two shelf) complete all as specified and directed. 73 Supply and fixing in repairs sheet glass corner shelf 300mm assembly consisting of 5.5mm thick sheet glass with chromium plated bracket guard and railingas approved by GE complete all as specified and directed. 74 Supply and fixing in repairs brass chromium plated handspray (Health faucet) with flexible pipe length not less than 1.00 m (minimum) fixed for EWC/IWC suitable for 15mm bore pipe complete all as specified and directed. 75 Supply and fixing in repairsbrass chromium plated paper holder for EWC complete all as specified and directed. 76 Supply and fixing in repairsof PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. 77 Supply and fixing in repairs of vitreous chinawater closet (squatt pattern) complete including provision of lime concrete bedding fixed in repair of orissa pattern size 580x440mm, white, with and includingfoot rest (excluding flooring cistern & flush pipe) complete all as specified and directed. 78 Supply and fixing in repair of vitreous china wash down water closet pan (pedestal pattern) white and trap including connection to drain flush pipe and anti syphonage pipe. 79 Supply and fixingin repairs EWC seat cover PVC colour as approved by GE including all fitting arrangements complete all as specified and directed. 80 Supply and fixing in repairs of vitreous china wash down water closet single piece snow white with P/S trap including vitreous china flush cistern with twin flush and seat coverconnection to drain flush pipe and anti syphonage pipe complete all as specified. 81 Supply and fixing in repairsPVC valveless syphonic action type flushing cistern low level 10ltrs capicty white, fixed with new brackets complete all as specifed and directed Make. 82 Supply and fixing in repairsof flush pipe of polythene of low or high density or PVC 32mm for low level cistern complete all as specified and directed. 83 Supply and fixing in repairs of vitreous china WHB white flat back size 550mmx400mm on new brackets excluding taps waste china & plug including bracket etc complete all as specified and directed. 84 Supply and fixing in repairs of vitreous china WHB white flat back size 550mmx400mm with pedestal on new brackets excluding taps waste china & plug including bracket etc complete all as specified and directed. 85 S&F in repairs vitreous china urinals, half stall type, white,complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing with automatic sensor based urinal spreader for flushing with brackets, flush pipe, grating and Union for discharge pipe including PVC waste pipe, CP waste coupling, sensor based urinal spreader complete all as specified and directed. 86 S&F in repair vitreous china urinal, full stall type, white with urinal spreader bedding urinal against wall in cement mortar 1:2 securing urinal to, plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed by Engineer-in-Charge. 87 Supply & fixing in repairs600 x 450 mm moulded glass looking mirror of selected quality and fixed to wooden plugs with chromium plated brass screws and cup washers in postion as directed. 88 Supply and fixing in repairsPVC Flexible waste pipe 32 mm dia with socket for steel sink upto floor level and length not less than 0.60 meter complete all as specified and directed. 89 Supply and fixing rotational moulded polyethylene water storage tank of capacity 1000 ltrs (Cylindrical vertical with closed top), three layer construction, ISI marked hoisted & fixed in position including GI light grade, over flow pipe 450mm and waste pipe 600mm long with all fitting etc. of 20 mm dia including dismantling/taking out of old water tank of having capacity of etc 500 ltr but not exc 1000 ltr & removing to site etc complete all as specified and as directed. 90 Supply and fixing rotational moulded polyethylene water storage tank of capacity 500 ltrs (Cylindrical vertical with closed top), three layer construction, ISI marked hoisted & fixed in position including GI light grade, over flow pipe 450mm and waste pipe 600mm long with all fitting etc. of 20 mm dia including dismantling/taking out of old water tank of having capacity of etc 250 Ltr but not exc 500 Ltr & removing to site etc complete all as specified and as directed. 91 Supply and fixing in repairs Gun-metal, globe or gate valves of 20mm bore with half turn lever arm /iron wheel head, screwed both ends for iron pipe complete all as specified and directed. 92 M&L 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete(1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge. 93 S&F in repair 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including necessary fittings complete all as specified and directed. 94 S&F in repair 75 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed. 95 S&F 75 mm dia PVC (SWR) bend any radius complete all as specified and directed. 96 S&F 75 mm dia PVC (SWR) junction single,(Single T) equal or unequal complete all as specified and directed. 97 S&F in repair 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including fittings complete all as specified and directed. 98 S&F in repair 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed. 99 S&F 110 mm dia PVC (SWR) bend any radius complete all as specified and directed. 100 S&F CP grating round 140mm size of PTMT (minimum weight 50 gms) complete all as specified and directed. 101 M&L for DWCPE (SN8) 180 (OD)/163(ID) mm diameter pipes laid in trenches including fittings complete all as specified and directed by Engi-in-charge. 102 Material & labour for construction of new stone masonary soakage well 3.0 meters dia and 3.0 meters effective depth inclunding soil work, in any type of soil, foudation in PCC 1:3:6, wall of honey combed masonary with top ring M25 concrete inclunding intercepting chamber abd screen chamber made of brick masonary in CM 1:6 RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete all as shown on drg No. CEAA/TD/80 Sheet 1/2 & 2/2 and as specified & diected by the Engineer in charge. 103 M&L for onsite LLDPE septic tank (conventional type) designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc complete for 25 users complete all as specified and directed. 104 M&L for stone walling of squared rubble,uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed. 105 Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete,such as switches, ceiling roses,pendents, regulators, sockets etc.removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge. 106 M&L for point wiring with 1.5 Sqmm multistrand, FRLS copper conductor cable, PVC insulated and unsheathed, drawing in and including PVC casing capping 20/25 mm dia medium grade ISI marked with all accessories such as bends, elbows reducers, pressed steel/ MS terminal boxes factory made 1.6 mm thick dully painted in rectangular shape appropriate sizefor one light/ fan point controlled by one 5 Amps switch one way, covered with 3 mm thick plastic laminated sheet top cover for mounting switches, sockets requlators etc and continous PVC insulated and unsheathed 1.5 Sqmm copper conductor cable multistrand as earth wire complete all as specified and directed. 107 All as per serial item No 106 above but 3 pin socket outlet, 5/6 amp on same board. 108 All as per serial item No 02 above but with 2.5 sqmm cable for independent one 6 pin 6/16 Amps socket outlet in and including2.5 Sq mm PVC insulated copper conductor unsheathed 1100 V grade IS-694 FRLS cable for continuous earth wire. 109 S&F in repair switch piano 5/6 amps flush type single pole one way complete all as specified and directed. 110 S&F in repair socket outlet flush type 5 pin 6 ampscomplete all as specified and directed. 111 S&F in repair switch piano 16 amps flush type single pole one way complete all as specified and directed. 112 S&F in repair socket outlet 2 in 1, 5 pin 16 amps flush typecomplete all as specified and directed. 113 Supply and fixing ceiling rose polycarbonate, isolated body 65 X 50 mm 2 to 3 terminalcomplete all as specified and directed. 114 Supply and fixing in repair non-metalic exhaust fan 300 mm sweep, 3/4/5 blade 230 volts, 1280 RPMconnecting up including provision of cable from ceiling rose/ connector to fan complete all as specified and as directed. 115 M&L for sub main wiring using two runs of single core PVC insulated cable with copper conductor multistranded 1100 volts of sizes 2.5 Sqmm through existing/ new non metalic PVC casing caping including copper earth wire in green colour of size 2.5 Sqmm connection to DB with thimbling complete as specified and directed. (Note:- Two runs of sub main wire including earth wire and rigid non metalic PVC conduit shall be measured as one unit per RM make of cable.) 116 S&F MCBs ofC series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Single pole 6 to 32 ampcomplete all as specified and directed. 117 S&F 240V 10 KA C curve miniature circuit breaker (MCB) of SPN 32 AMP and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. 118 Supply and fixing single pole neutral sheet metal enclosure for 04 way DBs when SPN to be used single phase 240 volts, single door complete all as specified and as directed. 119 Supply and fixing in repair LED 4 feet tube light fitting 1x 20W, 220V, AC metal body type connecting up withflexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.Make:- Crompton LDMTR20-CDL or equivalent approved in Havells/ Philips/ Bajaj/ Wipro. 120 Supply and fixing in repair LED 2 feet tube light fitting 1x 10W, 220V,AC polycarbonate body type connecting up withflexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and as directed. 121 M&L for cutting holes 300mm diameter for preparing opening through brick/stone masonary wall for fixing non-metallic exhaust fan 300mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall complete all as specified and as directed.
Contract Date: Oct 29, 2025 Contract Value : 28.09 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
35.
Defence #8152272 AOC
Tender For provision Of Otm Accn At Jaisalmer - 1 Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 29 to 30 2 Lump sum price worked out by the contractor for SITE CLEARANCE, EXCAVATION & EARTH WORKas listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 31 to 32 3 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 33 4 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 34 to 37 5 Lump sum price worked out by the contractor for ROAD/PATH/ CULVERT WORKS as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 38 to 41 6 Lump sum price worked out by the contractor for AREA DRAINAGE WORKSas listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 42 7 Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 43 to 44 8 Lump sum price worked out by the contractor for COMPOUND WALL, FENCING AND GATE WORKSas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No.45 to 46 9 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKSas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 47 10 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 48 to 52 11 Lump sum price worked out by the contractor for LIGHTNING PROTECTION WORKSas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 53 12 Lump sum price worked out by the contractor for AIR CONDITIONING AND MODERN LAUNDRY WORKSas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 54 13 Lump sum price worked out by the contractor for SUMMER APPLIANCES AND HOT WATER WORKSas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 55 to 56 14 Lump sum price worked out by the contractor for RAIN WATER HARVESTING AND ARBORICULTURE WORKSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 57 15 Lump sum price worked out by the contractor for DEMOLITION AND DISMANTLING WORKSas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 58 16 Sch A PART-XVI (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule. 17 PROVISIONAL LUMP SUM (PLS)Provide Provisional lump sum for: (a) Basket Ball Ground - 1 No(b) Valleyball Ground - 1 No 18 NOTES FOR ITEM NO 16.01:- (1) Provisional lump sum shall be expended wholly or in parts as directed by GE. The works under Provisional Lump Sum shall be measured and paid for at applicable rates in MES SSR 2020 Part-II subject to percentage ( + or - denomination) computed under last column of this schedule above/below the provisional lump sum price worked out by the MES. (2) For details refer relavent TD drawings.(3) All excavation and earthwork required for works catered in provisional lump sum shall be measured and paid under Sch A Part-II. 19 INTERNAL WATER SUPPLY OFFR ACCN / ADM BLDG OFFICE / MESSESSupply and fixing of 15 mm bore fancy type chromium plated pillar cock with wall flange, screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Cat Part No ORP-10001PM - 7037 or equivalent of any make specified in Appx C. 20 Supply and fixing of 15 mm bore fancy type chromium plated Central Hole Basin Mixer with Popup Waste System with 450mm Long Braided Hoses for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Cat Part No CON-169KNB or equivalent of any make specified in Appx C. 21 Supply and fixing of 15 mm bore fancy type chromium plated angular stop cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Queen Series Cat Part No QQT - 7053 or equivalent of any make specified in Appx C. 22 Supply and fixing of CP wall mixer 3 in 1 system with provision for hand shower and over head shower and including 1.5 m long tele shower screwed for iron pipes or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Queen Series Cat Part No QQT - 7281or equivalent of any make specified in Appx C. 23 Supply and fixing of overhead shower 150x150mm of square shape single flow with rubit cleaning system ABS body crome plated with gray face plate with arm having swivel joint chromium plated complete all as specified and directed.Make - Jaquar Queen Series Cat Part No OHS - 35495 or equivalent of any make specified in Appx C. 24 Supply and fixing of health faucit with 1200mm long flexible mild steel tube 15mm dia with wall hook and compete all as specified and directed.Make - Jaquar Queen Series Cat Part No ALD - 573s or equivalent of any make specified in Appx C. 25 JCO / OR ACCN & CHDHSupply and fixing of 15 mm bore fancy type chromium plated bib taps with wall flange, screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Essco Series or technocommercial equivalent of any make specified in Appx C. 26 Supply and fixing of 15 mm bore fancy type chromium plated pillar cock with wall flange, screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Essco Series or equivalent of any make specified in Appx C. 27 Supply and fixing of 15 mm bore fancy type chromium plated angular stop cock with wall flanged screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Essco Series or equivalent of any make specified in Appx C. 28 Supply and fixing of overhead shower 114x114mm of square shape single flow with rubit cleaning system ABS body crome plated with gray face plate with arm having swivel joint chromium plated complete all as specified and directed.Make - Jaquar Essco Series or equivalent of any make specified in Appx C. 29 Supply and fixing of two way bib cock with wall flange chromium plated fancy type 15 mm bore complete all as specified and directed.Make - Jaquar Series ORP-15041PM or equivalent of any make specified inAppx C. 30 INTERNAL ELECTRIFICATIONSupply and fixing TV sockets complete with all accessories all as specified and as directed . 31 Supply and fixing RJ 11 Gang with shutter (Telephone Jack) complete with all accessories all as specified and directed . 32 S & F LED batten suitble for indoor application 20 W, 4 length , wall mounted with aluminium housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.Make : Havells Cat part No LH EXACP7IN1W 020 or equivalent inCrompton/Philips 33 Supply & fixing LED lamp B22 base 10 W, min lumen output 950 lumens at 6500 K CCT for batten holders complete all as specified and as directed. 34 Supply & fixing LED batten suitble for indoor application 10 W, 2 length , wall mounted with polycarbonate housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed . 35 S & F 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 36 S & F 30 wattLED security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDs inbuilt electronic driver up to 4KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT5500-6500 CRI greater than 70 , input power 30W output operating voltage 140-280V with connection by three core PVC insulated multistranded copper conductor sheathed cable of size 1.0 sq mm fixed with & including bracket made of GI pipe 40mm bore light grade, 1.6 mtr long bent to shape required with 2 no MS clamps of suitable size and length, nuts & bolts complete all as specified and as directed. 37 M & L for drawing 12 pair /multi core coated copper telephone cable including PVC conduit of size 20mm complete all as specified and as directed. 38 SEWAGE DISPOSALM & L for construction of RCC septic tank 150 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls,base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter conventional type complete all as specified and directed. 39 M & L forOn site LLDPE conventional septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for., complete with effective depth of 1.5 m and overall depth of 3m for 25 users complete all as specified and as directed. 40 M & L for On site LLDPE conventional septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for., complete with effective depth of 1.5 m and overall depth of 3m for 10 users complete all as specified and as directed. 41 M & L for Soakage wells exc in any type of soil, fdn in PCC in 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intersepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25 SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats of size 1.2m dia and 3.0m effective depth for 10 Users complete all as specified and as directed. 42 M & L for Soakage wells exc in any type of soil, fdn in PCC in 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intersepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25 SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats of size 2.4m dia and 3.0m effective depth for 25 Users complete all as specified and as directed. 43 M & L for Soakage wells exc in any type of soil, fdn in PCC in 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intersepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25 SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats of size 3.0m dia and 3.0m effective depth for 150 Users complete all as specified and as directed. 44 COMPOUND WALL WORKSM&L Steel gate 5.50 mtr wide with RCC pillar ref TD CEJZ/TD/13 sheet 1/2 to 2/2complete all as specified and as directed. 45 M&L Steel gate 7.50 mtr wide with RCC pillar ref TD CEJZ/TD/13 sheet 1/2 to 2/2complete all as specified and as directed. 46 EXTERNAL WATER SUPPLY WORKSSupply, laying, jointing and testing of DI (Ductile iron) pressure pipes of size 100 mm dia bore with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS: 8329/2000 (latest revision) and other relevant standards and metallic zinc cozting followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar laid in trenches including testing on completion complete all as specified and directed.Note:- Ductile Iron Specials/Fittings, excavation and earth work shall bemeasured and paid separately. 47 Supplying, fixing and testing of DI pipe fittings for spigot socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing/ decreasing or double socket etc). Tees suitable for sockets or socket and spigot etc of size 100 to 250 bore in mm dia complete all as specified & directed.Note:- 1. Excavation and earthwork shall be measured and paid separately. 2. Unit rates includes for all jointing and jointing materials. 48 M&L for Construction of stone masonry new valve pit chamber of size 1050 mm X 1050 mm X 1050 mm (internal dimensions) with 100 mm thick PCC 1:4:8 type D-2 lean concrete foundation using 40 mm graded stone aggregate, providing stone masonry wall of 23 mm thick built in cement mortar 1:6 rendering in cement mortar 1:6 finished even smooth using extra cement internally and 20 mm thick in cement mortar 1:4 and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50 mm x50 mm x6 mm thick angle iron frame embedded in PCC coping with locking arrangement and 1 nos 50 mm size 4 levers lock with key in dupicate Standard size and MS hold fast and handle made out of 25 x 6 mm flat iron,applying two coat of anti corossive paint over one coats of zinc chrome primer including excavation earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. 49 All as per Item No 21.02 above but size of 600x600x600mm complete all as specified and as directed. 50 Supply, install, testing and commissioning of manufacturers factory assembled and tested electric driven monoblock pump set with electric motor, 415V, 3 phase complete of capable of delivering 10 LPS at 18-20 meter head comprising of coupled through a flexible coupling to a SPDP motorcomplete with starter and mounted on common MS base frame and foundations of the pump sets including PCC foundations, MS bolts with nuts and anti vibration pads. The work also includes the followings:-(a)Pump set capable of delivering 10 liters per second at 18-20 meters head coupled with electric driven motor of suitable size of make Kriloskar Brother or Equivalent of Mather& platt/ KSB. (b) GI suction pipe medium grade of suitable size and suitable lengthas required at site including all fitting.(C ) GI Delivery pipe medium grade of suitable size and suitable length as required at site including all fotting.(d)M&L for CI foot valve fixed with leather washer, cast iron non returning valve of suitable size, for suction & delivery side of pipe.(f)Vacuum gauge - 01No.(g)Pressure gauge diaphragm type upto 50kg/sqcm - 01No.(h)Priming arrangement of pump set by providing GI pipe 20mm bore, medium grade, gate valve etc from existing line (Not more than 10m away) with all fittings etc complete - 1Job. 51 Supply and fixing of 4.00 sqmm 3 core flat submerssible copper conductor cable complete all as speicified and directed 52 Supply and fix , test , commissioning of LT weather proof panel board powder coated indoor type double door shutter, made out of CRCA 2.0 mm thickouter and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with aluminiumbus barwith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved including provn of digital ammeter 0-50A,digital voltemeter 0-500 Volts, CTs of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etc. The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron )a) Aluminiumbus bar capacity 100 Amps for Phase-R-Y-B-3 Nos & neutral -1 No b) MCCB FP 16 KA 63 Amps - 1 Nos(I/C)c) MCB TPN 10 KA 32 Amps -2Nos (Forpump-02)d) MCB SPN10 KA 32 Amps - 1 Nos (for pumphouse bldg-01)(e) M&L for DOL starter suitable for 5 HP pump set - 02 Noscomplete with under voltage and overload protection, Single phase preventer mounted in indoor panel. with MCB TPN 16 Amps as incomer and also including necessary wiring with PVC insulated and unsheathed copper conductor cable multistranded of suitable size. 53 M&L for cutting of existing DI/CI pipe 350/150 dia and reducing to required length, in position, for insertion of collars or other fittings including necessary excavaton and earthwork, dewatering etc, if any involved, complete all as specified and directed. 54 EXTERNAL ELECTRIFICATION WORKSSupply and fixing, test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3 mm thickouter and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminiumbus barwith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved including provn of digital ammeter 0-500A,digital voltemeter 0-500 Volts, CTs of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etc. The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron) (Main Panel) 55 (a) Aluminium bus bar capacity 500 Amps for Phase-R-Y-B-3 Nos & one for neutral -1 No (b) MCCB FP 400 Amp, 35 KA for incoming-01 No (I/C)(c) MCCB FP 250 Amp 25 KA -01 No (O/G to FP-1 )(d) MCCB FP 100 Amp 25 KA -01 No (O/G to SM barrack) (e) MCCB FP 40 Amp 16 KA -03 Nos (O/G to ORs cookhouse, Trademen shop, Pump house) (f) MCCB FP 63 Amp 16 KA-01 No (O/G to laundary) (g) MCB SPN 20 Amp 10 KA - 02 Nos (O/G to qtr Guard & Security light) 56 Supply and fixing, test , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3 mm thickouter and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar , chamber and with Aluminiumbus barwith necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supplyas per CPRI approved including provn of digital ammeter 0-500A,digital voltemeter 0-500 Volts, CTs of suitable ratio,indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work alsoincludes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etc. The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron) (Feeder Panel - 01) 57 (a) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B-3 Nos & one for neutral -1 No (b) MCCB FP 250 Amp, 35 KA for incoming-01 No (I/C)(c) MCCB FP 100 Amp 25 KA -01 No (O/G to Adm bldg )(d) MCCB FP 63 Amp 16 KA -03 Nos (O/G to Single offrs living, JCO iving, JCO mess & club)(e) MCB TPN 32 Amp 10 KA -01 No (O/G to MT office)(f)MCB SPN 40 Amp 10 KA -01 No (O/G to B veh garage) (g) MCB SPN 20 Amp 10 KA - 02 Nos (O/G to Repair bay & Religious institute) (h) Timer ( FM/1QT Daily dial)-01(j)Contactor ML3,40 Amps-01 58 M & L for bracket made out of GI tubing 40mm dia, light grade 1.5 mtr long including fixing with MS clamps-2 Nos made Out of 25 mm wide 3 mm thick flat iron with M.S nuts bolts 75 mm long 12mm dia - 4 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc. complete all as specified and directed. 59 Supply & fix Hot Press Moulded SMC (Sheet moulding compound) Junction box of size 250x200x105mm Hinged (L) with 2 way connector mounted on epoxy insulators for looping of cable for 1 Phase and 1neutral fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40mmx4mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box. work also includes making suitable hole in pole to take out connections to fittinh if required at site and provisioning of 1.0 sqmm 3.0 core flexible PVC insulated copper cable from junction box to connector of street light, complete all as specified & directed. 60 Supply & fixing automatic street light switch of rating 3.0 kw in single phase using nature switch for mutomatic swithing ON/OFF of street lighting based on lux level of natural light along with contactor rating single phase 20 Amp single pole, MCB 20 Amps single pole (1 Nos) with support terminals prewired with PVC insulated strand copper wire enlosed/housed in pole wall mounted enclosure made of rust proof, shock proof, termit proof & dust proof FR grade special moulded compound Junction Box complete all sepcified & directed. 61 S & F Cable route indicator of size 100mm dia embossed as LT round shaped 10 mm thick with marking of 1.1 KV, LT welded bolted on angle iron of 25x25 of 60cm length grouted in PCC (1:3:6) type C-2 using block size of 150x150x150mm embedded in ground including not exceeding earth work complete all as specified and directed. 62 S & F Cable route indicator of size 100mm dia embossed as HT round shaped 10 mm thick with marking of 11 KV, LT welded bolted on angle iron of 25x25 of 60cm length grouted in PCC (1:3:6) type C-2 using block size of 150x150x150mm embedded in ground including not exceeding earth work complete all as specified and directed. 63 Supply & fixing post top lantern light fitting 25 Watt LED type with IP-65 protection Black ABS plastic spigot, spum aluminium canopy, with opal diffuser and accessories complete all as specified and directed. 64 Supply & fixing LED bollard light fitting 10 Watt, with IP 65 protection inverted pyramid light LED bolard of make crompton cart No LBLA2-10CDL or requiavalant any other approved make of PS complete all as specified and directed. 65 AIR CONDITIONING AND MODERN LAUNDRY WORKSSupply and fixing of Voltage stabilizer for automatic operation, single phasenaturally air cooled indoor type & designed for input variation between 170 V to250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and ofcapacity 5 KVA complete all as specified and directed . 66 Supply and fixing of Voltage stabilizer for automatic operation, single phasenaturally air cooled indoor type & designed for input variation between 170 V to250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and ofcapacity 4 KVA complete all as specified and directed . 67 Design supply, installation, testing & commissioning of washing Machine towash, dry for verious types of solid linen including all connected civil, electricaland mechanical works with and including:- (a) fully computerised washing machine, washer extractor,15 kg capacity percharge, electrical heater, front loading, auto timed auto reversed, auto stop autotemp control, auto level control, pneumatically operated valves for auto waterinlet, , auto drain. variable frequency drive for variable speed. programmablelogic controller (PLC), Iinner basket and outer body stainless-steel heavy-dutyMS fabricated structure.(b) Drying tumbler, 15 kg cap per charge, electric heated, front loading typeMicroprocessor based digital controller, auto timed auto reversed, auto stop withfully die pressed door, inner basket stainless steel, outer double walled insulatedwith glass wool complete all as specified and directed 68 SUMMER APPLIANCES AND HOT WATER WORKSSupply & installed of desert cooler electric driven (single phase) three speed having nominal air flow capacity 4000 CuM/hrs with propeller ISI marked cooler fan motor copper winding single phase fitted with & having 3/4 Nos blade, submersible pump, Cooler body made out from 20 gauge mild steel galvanized iron sheet & water tnak made out of 18 SWG having capacity 40 Ltr minimum including three louvers with wood wool pad, fiexible PVC distribution pipes and 3 way junction and including Angle iron stand with suitable size cpmpletely all as specifiedand directed.NOTE : The quated rate shall includes for the following :- (a) Three speed swich ISI Marked rotary type for propeller fan and one way switch pum with separate control. The switches shall have marking off-Low-medium and high.(b) Float valve on water on water supply connection.(c) S& F Stop Cock for sutiable size before the float valve is deemed to include in the item rate.(d) PVC connection of suitable length from stop cock to float valve etc.(e) S & F for angle Iron Stand of suitable size. 69 Supply, installed and testing of refrigrators,electric driven (single phase), not less than190/195 liters capacity ofBEE 5 stars rated , frost free, double door with humidity control and deoderizer, toughned glass shelves, stabilizer free operation, inverter technilogy compressor ,rust resistance body, dual thermostste for refrigeretor & freezer , with cool pack, completely all as specified and directed 70 Supply, installed and testing of refrigrators,electric driven (single phase), not less than360 liters capacity ofBEE 5 stars rated , frost free, double door with humidity control and deoderizer, toughned glass shelves, stabilizer free operation, inverter technilogy compressor ,rust resistance body, dual themostste for refrigeretor & freezer , with cool pack, completely all as specified and directed 71 Supply and fixing ofdigital Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA complete all as specified and as directed. 72 Supply and fixing of electric water heater, storage type steel body with glass line insulation tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated including all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. 73 RAIN WATER HARVESTING AND ARBORICULTURE WORKSM&L for filtration tank 2.00 m x1.50 m x1.00 m deep internal dimensionsbuilt inPCC solid block masonry in CM (1:6), PCC 1:4:8 type D-2 in fdn concrete 15mm thick plaster in cement mortar 1 :4 and RCC cover slab complete all asspecified. 74 ARBORICULTURESupply and plantation of sisam tree plant Ht of sapling 1.2 to 1.50 m withsaplings 90cm to 150cm height including excavation of suitable size pit 9size ofpit shall not less than 45 cm dia & 60 cm deep) to accommodate the roots ofplants including provn of good earth and treating with farm yard manure in theration (4:1) fertilizers and pesticides (i.e. Bevation and neem cake BHC 10%linson dust. Thimment or phorate, manures super and vermicompost) and makeup the trench area to proper levels for its growth and maintaining for one yearfrom the certified date of completion of work complete all as specified anddirecetd 75 All as per item No 25.01 above but Neem tree plant of sapling 1.20 to 1.50 mheight 76 S&F of tree guards made out of steel wire mesh of 5mm thick 100mm apertureweight n. exec. 4 kg/Sqm enclosed with three rings top, middle and bottom ofHot rolled steel flats 4mm th 20mm wide rivetted/welded with ends of barsshouldered and/or riveted and similar work confroming to FE 290 Gde-E-165and preparing new steel surfaces of any descroption exceeding 10cm width orgirth and applying two coats of synthetic enamel paint over a coat of red oxideprimer complete all as specified and directed. 77 NOOTES FOR ITEM NO 25.01 to 25.02 :- (i) Height of plant shall be measured from top of follage (not from the isolated branch / leaf, main stem) to 150mm from top of root. (ii) Water will not be supplied by MES for arboriculture. Contractor has to make his own arrangement for watering to plants and grass. (iii) The rates quoted by the contractor deemed to include watering, maintenance of plants / grass till one years after certified date of completion of work.(iv). During one years after completion if any plant / grass is found dead or not of satisfactory growth, plants / grass of approved size and shape shall be provided without any extra cost to the Govt.(v). Supply and application of manure, sweet earth and pesticides, fertilizers etc up to one years after completion are deemed to be included in the quoted unit rate.(vi) In case of failure by the contractor to maintain the plants / grass as above, the same shall be carried out by the department at his Risk and Cost.(vii) The plants shall be brought at site Six months before the date of completion of the work as per Work order. 78 NOTE FOR SCHEDUL OF CREDIT) Rs (-) 3850.00 AMOUNT DEDUCT FROM TOTAL QUOTED AMOUNT AT TIME OF ACCPTANCE OF TENDER.
Contract Date: Oct 25, 2025 Contract Value : 14.92 Crore
Statutory Bodies & Commissions/Committees No of Bidders 8
36.
Defence #8060499 AOC
Tender For Provision Of Living, Store And Toilet Under The Aor Of Ge 874 Ews.; 1 Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil complete all as specified and directed. 2 Excavation in trenches, n exc 1.50 mtr wide and n. Exc 1.50mtr in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 sqm on plan and getting out complete all as specified and directed. 3 Removing of excavated material exc. 250m but not exc 500m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 4 Returning filling in including spreading levelling watering & well ramming in layers n. exc 25cm thick complete all as specified and directed. 5 M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. 6 M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 as in wall/septic tank/soakage well complete all as specified and directed. 7 M&L for rendering 15mm thick on other than fair faces of brick work, stone masonry or concrete surface, in cement mortar 1:4 finishing the surface even and smooth without using extra cement, complete all as specified and directed. 8 M&L for applying two coats of cement base paint over a coat of Alkali resistant primer to newly plastered surfaces of wall including preparation of surface complete all as specified and directed. 9 M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. 10 M&L for hardcore of gauge n.exc. 63mm deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface of broken stone or boulders complete all as specified and directed. 11 M&L 75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection and finished even and fair, complete all as specified and as directed. 12 Supply and fix Vitrified Ceramic tiles light shade approved quality10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15 thick screed mortar in CM 1:6 complete all as specified and directed. 13 M&L for glazed ceramic coloured tiles in vertical surface of size 450X 350mm and 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour oftile over and including 15mm thick screed bed in CM 1:4complete all as specified and directed. 14 M&L Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed. 15 M&L 75mm thick PCC 1:4:8 Type D-2 (40mm graded aggregate) as in sub base flooring finishing cement concrete complete all as specified and directed. 16 M&L 50mm thick wall panel made of 0.5mm thick hot dipped galvanised steel sheet on both side with 50mm thick layer of grid cfc free closed cell polyurethane foam with tongue and groove joint including cam lock system for interlocking fixed on base panel 30x65x1.25mm thick density of foam shall be 40 kg/cum (+- 2 kg/cum) the panel shall be precoated coated as approved by GE complete all as specified and directed. 17 S&F pre painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screwincluding necessary scaffolding, anytype, any location/height complete all as specified and directed. 18 S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including necessary scaffolding, any type, any location/ height complete all as specified and directed. 19 M&L 40 mm (for ceiling) puff insulated panel made of 0.50mm thick hot dipped galvanised sheet on both side with 40mm thick ridge polyurethane foam provided with tongue and groove joint for interlocking ,to be fixed with inverted CRCA tee section 50x50x5mm thick andL section of 50x50x5mm thick fixed to roof trusses complete all as specified and directed. 20 M&L for sliding type three track aluminium window (SIZE_ 1.00M X 1.20M) or ventilator provided with top and side member 92x31.7x1.5mm thick (1.06 kg/RMminimum weight) bottom three track rail shall be 90x31.75x1.5mm(1.248 kg/Rm ) shutter shall of40x18x1.55 mm section (0.547 kg/Rm weight) shutter shall be provided with handle and self locking arrangement .Interlocking style shall of 40x18x1.45mm (0.607 kg/Rm ) panel shall be of 6mm thick clear grade 6/2 Rs 1.3mm polycarbonate sheet . The window shall be fixed to wall panel as standard practice two shutter shall glazed and one shutter shall be of stainless steel wire gauged complete all as specified and directed. 21 M&L for Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. with Powder coated (minimum thickness of powder coating 50 mm micron) aluminium frame for doors, windows , ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 22 S&F 4.8 mm thick tinted glass of selected quality in square not exceeding 0.5 sqm in each pane, fixed to aluminumframe with and including suitablerubber beadingcomplete all as specified and directed 23 S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. 24 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mmwood grain printedcolour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and directed. 25 S & F Mild Steel butt hinges 100mm long medium weight complete all as specified and directed. 26 S & F 200 size mild steel barrel tower bolts, stove enamelled black, with bright bolt complete all as specified and directed. 27 S & F Mild steel pressed handles, 150mm size, oval type, stove enamelled black 28 S & F vitreous China wash basin white flat back, size 550mmx450mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated, fancy type,pillar tap,15mm bore,screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed. 29 M & L for 50 mm thick insulated Puff door shutter made out of 0.5mm thick hot dipped galvanised iron sheet on both side with polyurethene foam, density of foam shall be 40kg/Cum (+2kg/Cum), the panel shll be precoated including suitable arragement for fixing of accessories complete all as specified and directed. 30 M&L 25 mm dia curtain rod mild steel powder colour coated fancy type with fixing arrangement for window and door the length shall be 450mm longer than opening size complete all as specified and directed. 31 M&L for mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe -410-W(gde-E-250) Quality A complete all as specified and directed. 32 M&L for mild teel work as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. 33 M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed. 34 M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm andn exc 15cm long, Diameter of neck in 11 to 15mm complete all as specified and directed. 35 M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc for finished surface of concrete complete all as specified and directed. 36 M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc for fair finished surface of concrete complete all as specified and directed. 37 M&L for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and directed. 38 M&L for Mild steel TMT bars 5mm dia and over and up to and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips. Gde-I,IS 432 (part I) complete all as specified and directed. 39 M&L for RCC M-25 as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed. 40 M&L for RCC M-25 as Columns, pillars, piers, posts and struts complete all as specified and directed. 41 S&F GI tube 15 mm dia medium grade galvanished with all fittings laid in floors /wall etc. complete all as specified and as directed. 42 S&F GI tube 20 mm dia medium grade galvanished with all fittings laid in floors /wall etc. complete all as specified and as directed. 43 S&F Stop valves cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15mm bore pipe complete all as specified and directed. 44 S&F bib taps cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed. 45 S&F vitreous China squatting pan, Orissa pattern, size 580 x 440 mm white with integral foot rests and connection with cast iron P trap and flushing pipe, including PVC valveless, syphonic action type, low level PVC flushing cistern 10 ltr capwhite with flush pipe & all fitting with provision of cement concrete bedding complete all as specified and directed. 46 M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete. 47 S&F 1000 Ltr capacity PVC water storage tank (cylindrical vertical with closed top) and fixed in position all as specified in SSR Part -I complete all as specified and directed. 48 S&F ball valves, high pressure, with polythene float and fly nut, 20mm bore complete all as specified and directed. 49 S&F 20mm bore gun metal globe or gate valve with iron wheel head, screwed both ends complete all as specified and directed. 50 S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. 51 S&F 110mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors / fixed to walls complete all as specified and directed. 52 S&F 75mm dia PVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches complete all as specified and directed. 53 S&F PVC (SWR) bends any radius, 110mm bore, fitted with oval access door complete all as specified and directed. 54 S & F 110mm dia PVC (SWR) pipe complete all as specified and directed complete all as specified and directed. 55 S&F PVC (SWR) bends any radius, 75mm bore, fitted with oval access door complete all as specified and directed. 56 S&F 110mm bore PVC (SWR) junction, single (single T) equal or unequal with door access complete all as specified and directed. 57 S&F 110mm bore PVC (SWR) junction, single (single Y) equal or unequal with door access complete all as specified and directed. 58 PVC (SWR) vent cowl 75/110 mm dia complete all as specified and directed. 59 S&F 600 mm x 450 mm size bevelled edge mirror of selected quality glass, mounted on 6 mm thick plywood and fixed to wooden plugs with chromium plated brass screws and cap washers complete all as specified and directed. 60 M&L PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed. 61 M&L for rough excavation not exc. 1.5 m deep and getting out in any type soil complete all as specified and directed. 62 Removal of excavated material and depositing where directed at a level n. exc. 1.5 m above the starting point exc. 500 m distance but n exc 750m complete all as specified and directed. 63 M&L for conventional 10 users on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil including providing PCC (1:4:8) type D-2, 150 mm thick in foundation, Vent shaft, connection etc., complete all as specified and directed. 64 M&L for construction of Soakage well, of size 1.20 m dia at bottom and 3.00 m effective depth complete all as specified and shown on drawing No. CESZ-TD-/2015 sheet No 1/3 & 3/3 dated 22 Feb 2015 (Revised dt 21 Mar 2015) and specified in particular specifications. 65 M&L for SGSW line 150mm dia SGSW pipe laid in trenches and jointed complete all as specified and directed. 66 M&L for concrete bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D2 (using 40mm graded aggregate) for 150mm bore pipe complete all as specified and directed. 67 M&L for machine pressed precast concrete, rubberised finished, interlocking paver block any shape and size confirming to IS-15658-2006 of 60 mm thick M-35 grade with grey cement and no pigment over 30mm thick sand filing under floors or pavers complete all as specified and directed. 68 Removing excavated material and depositing where directed at a level n. exc. 1.5 m above the starting point beyond 750m and upto a total distance of 1 Km complete all as specified and directed. 69 M&L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, kneelers, apex stone, bed plates and the like including weathering slightly rounded or chamfered angles and throating, complete all as specified and directed. 70 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed 71 Supply only liquid water proofing compound complete all as specified and directed. 72 M&L for RCC M-30 as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed. 73 M&L for RCC M-30 as in Columns, pillars, piers, posts and struts complete all as specified and directed. 74 M&L for RCC M-30 as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified. 75 M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed. 76 M&L rendering 15mm thick on fair faces of brick work, stone masonry or concrete surface, in cement mortar 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed. 77 M & L for preparation of new plaster surface of wall and applying two coats of cement based paint on external wall surfaces over a coat of primer including preparation newly plastered surface complete all as specified and directed. 78 M&L for 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregates as in sub base to floor/path/hardstanding etc. complete all as specified and directed. 79 M&L for machine cut kota stone slab flooring 20-25mm thick over and including 15 mm thick cement screed base in CM(1:6)laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed 80 M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado, pillar laid over and including 10mm thick cement screed bed in CM (1:4) and jointed with complete all as specified and directed. 81 S&F false ceiling E-Board 600x 600mm tile 10mm thick semi perforated coloured, Anodised aluminium snap grid frame work (Size of grid 605 x 605mm) with GI suspended system, metal frame work, G.I. wire mesh in false ceiling complete all as specified and directed. 82 S & F Steel windows with side hung shutters including frame, projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed. 83 S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors etc complete all as specified and directed. 84 S&F Mild steel, plain, black sheet 1.60 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. 85 S&F mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, Fe 410 -W (Gde-E- 250) quality-A drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. 86 S&F Cast iron or malleable cast iron handles 150mm, cast type, stove enamelled black complete all as specified and directed. 87 S&F MS flat iron as in hold fast, pintle hinge etc complete all as specified and directed. 88 S & F 300 mm long steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. 89 M & L PCC 1:3:6 type C - 2 in foundation, filling and mass concrete (using 40 mm graded crushed stone aggregate). 90 M&L for stone walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in CM 1:4 91 Extra over stone walling for hammer dressing to face of stones and dressing of face beds and joints, as specified of random rubble walling uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 20 mm on granite or trap stone. 92 M&L extra for forming fair finished drain or channel 45 cm inner girth in cement concrete using extra cement, including forms, moulds etc. 93 M & L for point wiring with PVC insulated unsheathed single core multistranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, drawn through PVC casing caping/conduit pipe (as per site requirement)including accessories and provision of PVC boxes for mounting switches, switch socket, fan regulator, provision of modular Terressa plate Irene stripes, No of modules as required on site or as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) earth wire and connected to earth dolly complete all as specified and directed or one fan/one bell point controlled by one switch. 94 All as per item No 93 above but for one socket outlet 5 pins 5 amps controlled by one switch on same board. 95 All as per item No 93 above but for one socket outlet 5 pins 5 amps controlled by one switch on independent board. 96 All as per item No 93 herein before but wiring with 2.5 sqmm copper wire (FRLS)and 2.5 sqmm earth wire for socket outlet 6 pin 15 amps on independent board. 97 M & L for Switch socket combination 5 in 1, 3 pin, 6 Amp and 16 Amps flush type universal complete all as specified and directed. 98 S&F switch piano flush button single pole, one way 5 amps complete all as specified and directed. 99 S & F switch socket combination 2 in 1, 5A flush type complete all as specified and directed. 100 S&F socket outlet multi purpose 5 pins 5 amp, complete all as specified and directed. 101 Supply and fix water heater storage type, electric capacity 25 ltr along with all accessories BEE 5 star rated complete all as specified and directed. 102 M & L for ceiling rose, PVC/Polycarbonatethree terminalscomplete all as specified and directed. 103 Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 104 Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 105 Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V , 50 Hz, RPM 1200, cooper winding of sweep 300 complete all as specified and directed. 106 M & L sheet metal enclosure for DBs 8 way double door type with 200amps rated busbar SPN including necessary connection complete all as specified and directed. 107 S&F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 4 way incl blanking plate as required with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. 108 S&F MCBs single pole 240 volts 6 to 32Amps 10 KA C series complete all as specified and directed. 109 S&F MCB single pole & neutral 40 to 63 Amps 230 VoltsC series, 10 KA complete all as specified and directed. 110 Supply and fixing in replacement Exhaust fan AC single phase, 1200 rpm 230/240V of size 250mm sweep with louvre heavy duty complete all as specified and directed. 111 Supply and fix in replacement, water heater storage type , electric capacity 25 ltr along with all accessories BEE 5 star rated, complete all as specified and directed. 112 S&F in repair building security light fitting in repair LED 35 Wattfor Energy saving and environmental friendly long life made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 including driver unit and bracket made up of GI tube of suitable size (1.2 Mtr Length)etc complete all as specified and directed. 113 M & L for sub main wiring with two single core 2.5 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor FRLS ISI marked drawn into & including medium grade PVC conduit/ casing caping25 mm dia with all fittings and accessoriesand one continuous run of 2.5 sqmm copper conductor PVC insulated (green colour) as earth wire fixed into PVC casing / conduit (not less than 25mm outer dia) with all fittings and accessories fixed concealed/ surfaceincluding taking down old unserviceable submain wiring and making good disturbed surfacecomplete all as specified and directed. 114 M&L earthing complete with galvanised earthy plate electrode 600 x 600 x 6 mm thick buried directly in ground ( earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 meter below normal ground level, the earth plate surrounded by a mixture of charcoal dust and salt to a packed thickness of 150 mm on all sides with and including necessary excavation earth work returning, filling in and removal of surplus soil upto 50 mtr including GI wire 4 mm dia bolted and riveted to earth plate at one end in and connected to continuous GI earth wire encased in and including 15 mm GI light grade pipe with all fittings from top edge of earth plate as shown in electrical plate no 3. complete all as specified and directed. 115 S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminium stranded conductor served with PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm diaGI suspension ire one twin core flat cable of circular of size 16 sqmmcomplete all as specified and directed. 116 Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed. 117 M&L for sand cushioning for protection of PVC cable with approved sand of uniform thickness, laid dry, by filling in trenches and punning to proper required complete all as specified and directed. 118 M & L Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed. 119 Supply and fix in replacement of off load changeover switch AC, 4 pole, 415 volt upto 125/200 AMP complete all as specified and directed. 120 S&F GI water tubing 25mm bore medium grade, galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed complete all as specified and directed. 121 S&F gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of bore of 25mm complete all as specified and directed. 122 M&L for Ferrule the existing main water supply pipe line 150/100/80 mm bore CI/DI/GI line for branch connection of the internal dia 20 mmStraight plain brass ferrules (or connecting screws) screwed both ends and internal dia 40 mm complete all as specified and directed. 123 Supply and Fixing Earth continuity conductor with 25x3 mm aluminium strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any ther indicated situation for loop earthing etc complete all as specified and as directed. 124 Supply and Fixing Earth continuity conductor with 32x6 mm GI strip fixed to wall on batten or recess or chases with necessary porcelain insulators or buried in ground or drawn in conduit/pipe/wall or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and as directed. 125 Supply and fixing porcelain/epoxy white / brown / green spacer insulator with one GI stud bolt with nut and washer with necessary drilling for bolt hole for holding / fixing roof conductor / down conductor of lightning conductor complete all as specified and as directed 126 Supply and fix GI pipe 40mm dia light grade for protection ofEarth strip lain in trenches or on walls with necessary clamps all as specified and as directed. 127 Supply and fix single pointed air termination aluminium rod 12-mm dia 300 mm long with fixing arrangement including dismantling of old unserviceable/ de shaped conductor and removed from site of work complete all as specified and as directed 128 M&L of test point terminal block made of gunmetal of phosphor bronze size 75x75x25mm drilled and screw including 3 Nos 8mm dia 25mm long hex head screw with necessary arrangement for fixing to wall complete all as specified and directed. 129 M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected tousing galvanised iron strip 32×6mm as earthing lead earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed.
Contract Date: Sep 24, 2025 Contract Value : 48.76 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Jammu And Kashmir View Result →
37.
Tourism #8044753 AOC
Tender For Providing Additional Tourism Facility At Mtdc Resort Trc Nagpur Dist Nagpur-1 Stamp Concrete of 100mm Thickness - Providing and Laying in-situ M30 Grade unreinforced plain cement stamp concrete of 100mm thickness pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate (natural sand / VSI grade finely washed crushed sand) Confirming to IS 383, as per mixed in a batching and mixing plant / non tilting mixer and weigh batcher as per approved mix design, admixtures, transporting to site in nagpur city with lead upto 20KM (on Inner Ring Road from Avasti nagar to wadi), spreading, laying with approved make pover, compacted and finished in a continous operation, finishing to lines and grades Also Providing, Placing and applying stamp powder which is light fast UV resistant pigment with appropriate chemical compounds of desired colour on base concrete after excess bleed water has evaporated using dry shake method @5kg per sqm. Including texturing, and covering with plastic sheet (min 200 micron thickness) and also applying two coats of UV-stable,30 % solids clear sealer @ 150 to 250 gms per sqm using surface roller and protecting from falling dust,dirt and curring by curring compound / by providing cement vata in cement Mortor 1 :8 @ 0.6m x 0.6m center to center, admeasuring 80mm at bottom and 40mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-incharge or Landscape architect etc. complete. (prior approval of superinteding Engineer will be necessary ) 2 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete 3 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. 4 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item One Number 15 to 18 prior approval of Superintending Engineer will be necessary 5 Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. 6 Providing & Applying chemical for cleaning the exposed steel structure, TMT bars, etc. of structure by grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal also removing loose particles, of the area by water jet, (using other mechanical / manual means) and apply on prepared surface of as corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturers specification using other manual / mechinical means) after that Providing and applying high abrasive resistant, self curing, UV resistant,impermeable ,high strength, non shrink, Poly Ironite Ceramic Cementatious (PICC) repair mortar resurfacing on concrete surface of thickness up to 10 mm including breaking honey comb area, (using manual/mechanical means) , clean the concrete surface with special chemical clonon with pressure water jet for removing of algae fungi, apply bond coat Kelox water misible epoxy before PICC application with all leads and lifts, Material, Machinery, labour, scaffolding, etc. complete as per specification and as directed by engineer-in-charge. 7 Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat 8 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete 9 Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. 10 Providing and fixing 40mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete 11 Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) 12 Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary) 13 Providing Water proofing treatment to old terraces by removing existing treatment, sealing of cracks by non shrink crack fill compound applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion (1 litre polymer : 2 Kg Cement ) to a neatly cleaned and dust free concrete surface and upto 300 mm over parapet wall prepared by removing loose and deposited material with brush and water, followed by a coat of flexible cementious coating eg. MYK-Aqufine U.M., EL Monobond or equivalent as per manufacturer specification after laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover of 20 mm water proof plaster after sufficient curing 40 to 75 mm IPS 1:2: proportion using coarse aggregate of 10 MSA and water proofing compound and polypropylene fibres @ 125 gm per bag of cement within it conforming to IS in pannels making groove 3 to 4 mm wide & 10 mm deep & 3m/4m or as per site condition & filling the joints with polt sulphide sealant after curing, including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry including curing as directed and ponding the surface as directed etc. complete; covering 10 years guarantee against leakproofness on Court Fee Stamp Paper of Rs. 100/- 14 Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. 15 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25- 30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, selfdrilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) 16 Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. 17 Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. Contractor No. of Corrections 18 Providing and constructing Columns ,footing & steel including Design supply fabrication & erection Tensile structure Roof with Fabric of 900 Gsm both side Coated with PVDF Lacquer System on both sides,titanium dioxide front side primer,low-wick,protected aginst microbial and fungal attack,UV- protected top caot of 2 grade of required colour and shap and design including necessary M.S.tensile steel structure of hollow section,gusset plates bolts nuts,screws etc. complete with one coat of epoxy primer and two caot epoxy paint etc. complete as specified and approved by architect the complete structrual structure Designed to withstand the wind pressure as per IS (PART III), to accmmodate thermal expansion and seismic movement etc The rate shall include all design calculations, engineering and slope drawing Including approval from cometent structural designer,Labour T &P scaffolding other incidental cahrges including wastage enabling temporary service all fitting fixtures complete as per technical specfication .for the purpose of Payment actual surafce area of fabric shall measured etc. 19 Machine polishing to cement/marble mosaic tiled flooring or any other type of flooring including cleaning, washing, etc. complete. 20 Supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to convertible mode for compressor, room airconditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unithi-wall/floor mounting type complete with refrigerant R32 having coppercondenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation& temperature display indoor unit, noise level maximum 50dBA at position asper specification no. APAC/ WAC 21 Executives Table @ 1800Lx900Dx750HT Providing & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing 22 Wall lining butch work upto 10m height with Dholpur Stone 40mm thick rogh facing on the exposed surface with stone strips of minimum length 300mm and required width, including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75x75mm and by providing layer of 75mm thick strips i/c 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) i/c ruled pointing in cement mortar 1:2 ( 1 white cement:2 stone dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in-charge. 23 Providing and supplying good quality cotton Turkish type (Face Towel) napkins. Of size 405 mm x405 mm of approved colour and quality as directed by engineer in charge et. Complete.Specification as Directed by Engineer-in-charge etc,complete. PS good quality cotton Turkish type (Face Towel) napkins 24 Providing and supplying good quality cotton Turkish Type Bath Towel. 690 mm x 1321 mm of approved colour and quality as directed by engineer in charge et. Complete .Specification as Directed by Engineer-in-charge etc,complete. PS good quality cotton Turkish Type Bath Towel. 25 Pillow Cover of standard size of 100% cotton for a light and airy feel- without any added chemicals. 26 Duvet Double size 90 X 100 as per directed by Engineer In Charge 27 3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm. 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. 28 Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. 29 Providing wax polishing to floors and dado, preparing the surface, scaffolding etc. complete. 30 Providign & Fixing Wall Paper at wall suraface etc. 31 Crushing Value/Compressive Strength, Water Absorption & Specific Gravity, 32 Flooring of Natural Stone (Kota,Marble, Granite,Tandur.etc.) Water absorption, Specific gravity 33 Royalty Charges 1 Cement OPC/PPC 2 Steel 3 Pine wood 4 Wooden Flush Doors 5 Flush Door 6 Flush Door Shutter 7 Waterproof Ply 8 Commercial ply 9 Veneer 10 Laminate 11 Pre-laminated particle board-Exterior grade 12 Gypsum board. 13 Block Board / Ply 14 PVB/ Laminate Film 15 Cement Boards / Sheets / Panel 16 Door Hardware 17 Door Lock & Handle 18 Door closer 19 Door Locks (Concealed / Surface mounted) 20 Locks 21 Door Seal – Wool pile Weather Strip 22 Door Handle (Concealed / Surface 23 Stainless Steel Screws for fabrication and fixing of windows 24 Two or Four Point locking Openable Window Handle 25 Butt Hinges openable Window shutters 26 Nuts Bolts /Screws 27 Concealed Tower Bolt 28 Patch Fitting 29 UPVC Joinery 30 M.S. Pipe, Tubes, Bar, Flats, Angle, Tee Sections 31 Acoustic Insulation 32 Glass 33 Vitrified Ceramic Tiles 34 Glazed Ceramic Tiles 35 Paint/primer/oil bound distemper Acrylic paint 36 Mirror 37 Vitreous China Sanitaryware 38 Concealed Flushing Cisterns 39 European water closet 40 Sensor Operated Flushing System 41 Seat covers (Heavy Duty) 42 Flat Back Urinal (Sensor Operated 43 Urinal 44 Wash basin 45 SEMI-RECESSED BASIN 46 Telephonic Shower 47 C.P fittings & Bathroom accessories 48 Health Faucet 49 Soap Dispensar 50 Stainless Steel Sink 51 C.P Bottle Trap 52 Sink mixer with regular swinging spout 53 Basin Mixer 54 Waste coupling 55 C.P. Grating 56 CP / SS Grating for Floor Trap & Floor Drain 35 Paint/primer/oil bound distemper Acrylic paint 36 Mirror 37 Vitreous China Sanitaryware 38 Concealed Flushing Cisterns 39 European water closet 40 Sensor Operated Flushing System 41 Seat covers (Heavy Duty) 42 Flat Back Urinal (Sensor Operated 43 Urinal 44 Wash basin 45 SEMI-RECESSED BASIN 46 Telephonic Shower 47 C.P fittings & Bathroom accessories 48 Health Faucet 49 Soap Dispensar 50 Stainless Steel Sink 51 C.P Bottle Trap 52 Sink mixer with regular swinging spout 53 Basin Mixer 54 Waste coupling 55 C.P. Grating 56 CP / SS Grating for Floor Trap & Floor Drain 79 UPVC pipes/fittings 80 UPVC ASTM pipes 81 CPVC Pipes and Fittings 82 Copper Pipes 83 G.I. Pipes / M.S. Pipe 84 G.I. fittings (malleable cast iron) 85 C.I. fittings 86 C.I pipe & Fittings 87 Sand Cast Iron Pipes & fittings 88 PVC KHURRA 89 Pressure Guage 90 RCC Grating 91 C.I manhole cover & framing 92 Insulation 93 Pre-Fabricated Structural supports and clamps 94 pumps 95 Aluminium Systems/ Anodized aluminum fittings for doors/windows 96 Aluminium Cleat arrangement for Glazings / Cur. Wall size 97 Aluminium Sections 98 E.P.D.M. Gaskets 99 Water stops 100 PVC Perforated Pipes 101 Anchor Fasteners / bolts 102 Masking Tapes 103 Bio digestor 104 Sewage Treatment Plant 105 Organic Waste Digester 106 PVC pipes and accessories 107 HDPE Sheets 108 Mattress 109 Pillows with cover 110 Bed sheet 111 Solace blanket 112 Bamboo Furniture 113 Television 114 Set Top Box 115 Sluice valve 116 GYM Equipments 117 Battery operated cars 118 Bumpy Boats 119 Amusement Rides 120 Sauna and Steam Bath 121 Shingles 122 Water proof cement paint 123 Metal Deck Sheet
Contract Date: Sep 30, 2025 Contract Value : 76.95 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
38.
Defence #8044738 AOC
Tender For Provision Of Wksp Repair Est At Leh Under Ge I P No 1 Leh; 1 NOTE: Schedule ‘A’ Part - ItoPart -XIIare Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 2 Total amount of Sch A Part - I (BUILDINGS) 3 Total amount of Sch A Part - II(SITE CLEARANCE WORKS) 4 Total amount of Sch ‘A’ Part - III (PROTECTIVE WORK) 5 Total amount of Sch ‘A’ Part - IV (ROAD WORKS) 6 Total amount of Sch ‘A’ Part - V (SEWAGE DISPOSAL WORKS) 7 Total amount of Sch ‘A’ Part - VI (SECURITY WALL WORKS) 8 Total amount of Sch ‘A’ Part - VII (INTERNAL WATER SUPPLY WORKS) 9 Total amount of Sch ‘A’ Part - VIII (INTERNAL ELECTRIC SUPPLY WORKS) 10 Total amount of Sch A Part - IX (EXTRNAL WATER SUPPLY WORKS) 11 Total amount of Sch A Part - X(EXTRNAL ELECTRIC SUPPLY WORKS) 12 Total amount of Sch ‘A’ Part - XI ( STREET LIGHT WORKS) 13 Total amount of Sch ‘A’ Part - XII ( STANDBY DG SET FOR CHS WORKS) 14 SCH A PART - XIII(Miscellaneous B/R and E/M works for Sch A Part-II to Part-XII)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 15 Supplying and fixing30 users LLDPE septic tank designed to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft , connection etc conventional typecomplete all as specified and directed by Engrs-in-Charge. 16 Supplying and fixing 10 users LLDPE septic tank designed to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft , connection etc conventional type complete all as specified and directed by Engrs-in-Charge. 17 Construction of soakage well 2.4m internal dia and3.00m effective depth including excavation in any type of soil , foundation in PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregates ), PCC Block honeycomb/ solid masonry in cement mortar (1:4) RCC M-30 design Mix cover Slab filled with stone boulders including intersepting chamber screen chamber and disposal of soil complete all as specified and shown on drawings. 18 Construction of soakage well 1.2m internal dia and3.00m effective depth including excavation in any type of soil , foundation in PCC 1:3:6 type C-1 ( using 20mm graded crushed stone aggregates ), PCC Block honeycomb/ solid masonry in cement mortar (1:4) RCC M-30 design Mix cover Slab filled with stone boulders including intersepting chamber screen chamber and disposal of soil complete all as specified and shown on drawings. 19 Supplying and fixing for Concertina Coil Punched type 610mm dia razor type made out of 2.50 mm dia SG hot galvanised spiring tensile wire 145 to 150 N/SQMM zinc coating 240 gms/sqmm (min) weight of coil shall be minimum 8.57 kg/coil shall be 6.25 RM after laying, min Nos of turns in each coil shall be of 49/50. Galvanized razor ribbon type shall be of size 0.50 mm thick, 19 mm side before wrapping on central core wire. Concretina coil shall be fixed to existing angle iron swan neck supports using GI clips 125 to 127 Nos per coil and special nuts and bolts for holding Z coil together and extra two rows parallel wire of 10 gauge etc all as specified. 20 M & L for MS wicket gate as Ref drwg- CELZ/TD/ST-11/2017 SHEET 1R/1 Complete all as specified and directed by Engrs-in-Charge. 21 M & L for 5.5 Mtr Wide gate with pillers Ref drwg- CELZ/TD/ST-11/2017 SHEET 1R/1 Complete all as specified and directed by Engrs-in-Charge. 22 Supply, Install, lowering, testing, and commissioning of submersible openwell pumping sets, centrifugal, electric driven,minium discharge of 23.46 LPM at 33 mtr headmotor capacity minium 3 HP including 3 HP Starter complete all specified and directed. 23 Supply, installation, testing and commissioning of LT Feeder Pillar Box, out door type, vermin proof, front dooropenable, made out of CRCA Sheet 3.15 mm thick, duly powder coated, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following.a) Bus bar chamber with and including copper strips (set 4 nos) suitable for 100 amps duly insulated wired & duly mounted on porcelain insulators b) Incommer MCCB 4 Pole 440 Volts, 40 Amps rating with repturing capacity 16 KA - 1 Noc) Outgoing MCCB 4 Pole, 16 Amps rating with repturing capacity 16 KA - 2 No (for Openwell Submersible pumpset)d)Three Ph LED electronic Ammeter Class 1 with in built selector switch having range 0 to 100 Amp - 01 Noe) Three Ph LED electronic VoltmeterClass 1 with in built selector switch having range 0 to 500 Volts- 01 Nosf) Indicator RYB . LED type- 1 Set.g) All accessories prewired with appropriate size copper strip or wire thimbles etc. 24 h) Space for Provn of DOL starter 3 HP - 02 NosAll as required including foundations as per Manufacturers recommendations all as required at siteor as directed by Engr-in-Charge. (j) As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 25 Supply and fix submersible copper conductor cable 3 core, 4 sqmm 1100 volt flat industrial grade including nylon binding wire and accesories to clamp with column pipe at two places to each column pipe complete all specified and directed. 26 M&L for Construction of brick masonary valve pit of size.0.9X0.9X1.8 mtr (internal diamensions) including excavation and earth work in any type of soil, PCC 1:4:8 type B-2 in foundation brick work in CM 1:4, 15mm thick plastering in CM 1:4 internally and flush pointing externally in same mortar as the work process angle iron frame 40X40X6mm,with 3mm thick MS sheet cover with 12 mm dia handle and locking arrangement (including lock and two Keys) and two coats of synthetic enamel paint over a coat of red oxide primer, filling saw dust into the pit and providing extension rod 0.6 m long to operate sluice valve from top and welding it with sluice valve spindle all as specified and directed by Engr-in-charge. 27 Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.5m x 1.2m x 0.7m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including the following :- (Prop Main LT Panel)(Near Prop Transformer)(a) Copper bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 2400 Amps.(b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1600 Amps - 01 No for incoming(c) As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 28 (c) MCCB 4 Pole, 415 V, 36 KA, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 02 No O/G (for Prop Sub LT Panel, Spare)(d) ACB 800 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No O/G (for CHS LT Panel) (e) MCCB 25 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 03 No O/G (for High Mast light No.1,2 & Feeder Pillar box)(f) Indicator Lamp LED type (RYB) - 01 Set (g) Digital type Ammeter 3 Ph with in built selector switchsuitable up to 1600 Amp including suitable rating CTs -01 Set(h) Digital type Voltmeter 3 Ph with in built selector switchsuitable up to 500 Volt- 01 Set(j) All accessories prewired with appropriate size copper strip or wire thimbles etc.All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge. 29 Supply, installation, commissioning and testing of factory made, CPRI approved LT panel of size 1.2m x 1.2m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including the following :- (Prop Sub LT Panel)(Near workshop bldg)(a) Copper bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 1000 Amps.(b) MCCB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps - 01 No for incoming(c) As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 30 (c) MCCB 250 Amps, 415 Volt, 36 KA, 4 Pole, thermal magnetic release - 01 No O/G (for VTPN DB No.1)(d) MCCB 63 Amps, 415 Volt, 25 KA, 4 Pole, thermal magnetic release - 01 Nos O/G (for VTPN DB No 2)(e) MCCB 160 Amps, 415 Volt, 25 KA, 4 Pole, thermal magnetic release - 01 Nos O/G (for VTPN DB No 3)(f) MCCB 100 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No O/G (for VTPN DB No 4)(g) Indicator Lamp LED type (RYB) - 01 Set (h) Digital type Ammeter 3 Ph with in built selector switchsuitable up to 600 Amp including suitable rating CTs -01 Set(j) Digital type Voltmeter 3 Ph with in built selector switchsuitable up to 500 Volt- 01 Set(k) All accessories prewired with appropriate size copper strip or wire thimbles etc.All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge. 31 Supply, installation, commissioning and testing of factory made, CPRI approved feeder piller box of size 0.9m x0.9m x 0.6m, outdoor type made out of CRCA sheet 3.15 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, grounting the legs of panel in PCC foundation 1:4:8 platform complete as all directed suitable for and including fwg:- (Feeder Pillar box) (Near washing platform) 32 (a) Copper bus bar, 3 Phase , 4 wire , AC Supply system 50 Hz mounted on epoxy based Post insulators, including drilling hole for cable connection, rating of bus bar 50 Amps.(b) MCCB 25 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No incomer(c) MCCB 16 Amps, 415 Volt, 16 KA, 4 Pole, thermal magnetic release - 01 No outgoing(d) Earth plug socket 3 ph 415 V, 32 Amp - 01 No(e) Switch socket combination 5/15 Amps 5/6 pin - 02 Nos(f) Indicator Lamp LED type (RYB) - 01 Set (g) Digital type Ammeter 3 Ph with in built selector switchsuitable up to 400 Amp including suitable rating CTs -01 Set(h) Digital type Voltmeter 3 Ph with in built selector switchsuitable up to 500 Volt- 01 Set(j) All accessories prewired with appropriate size copper strip or wire thimbles etc.All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge. (k) As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 33 Labour for boring underground upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified. 34 Supply, Installation, Testing & Commissioning of High galvanized mast light suitable for 8 luminaries symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation suitable for 12.5 Mtr height completed minimum dimension specified as under mentioned specifications.Note : As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule.(A) High Mast Structure1. Matrial of Construction:- HR sheet steel conform to IS 2062/BS EN 10025 or Equivalent2. Base Dia. and top diameter (A/F) 1. Top Section - 150 mm 2. Bottom Section - 360 mm3. Plate thickness :- Top - 3mm, Bottom - 3 mm4. Cross Section of Mast (Number of Slides) - 20 Sided Polygon5. Standard of galvanisation - As per BS EN ISO 14616. Size of opening and door at base - 1050 x 225 mm7. Diameter of base plate - 520 mm8. Thickness of base plate - 25 mm9. Lighting protection finial - G.I single spike 35 10. Max. wind speed - 50 m/s as per IS : 875 (Part -III)11. Number of foundation bolts - 4 nos12. Type/ diameter/ length of foundation bolts - TS 600/ 24 mm dia/ 850 mm long13. PCD of foundation bolts - 445 mm(B) Luminaires Carriage :- 1. Material of construction - 40 NB ERW Class B - M.S. pipe2. Diameter of carriage ring (mm) - 450 mm (ID)3. Construction - 4 Arm, welded, 2 sections4. Load Carrying capacity - 08 Luminaires(C) Trailing Cable :- 1. Conductor - Copper, 5 core, 2.5 Sqmm 2. Insulation -PVC insulated3. No of circuits per mast - One no. cable per mast (D) Winch/ Power Tool1. Type /SWL of winch - Double drum, SWL 350 Kg2. Method of seperation - Integral Motor3. Motor capacity - 0.75 HP4. No of speeds - 6 pole, single speed5. Torque limitor - with mechanical tripping facility(E) Stainless steel wire rope 1. Grade/ Construction - AISI 304, 7/19 construction2. No of ropes - Two continuous3. Diameter (mm) - 5 mm4. Breaking load capacity - 1350 Kg x 2 36 S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 250 Amps rating with rupturing cap 36 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. 37 S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. 38 S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. 39 S&F Vertical TPN Loadline distribution board iron clad, doube door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as ougoing 415 Volts 3 phase 50 C/s 8 way, complete with appropriate size copper bus bar and neutral link, confirming to Cat Pt No DHDLVSRWGOFO08 of Havells or equivalent of make Legrand/ABB complete with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connections with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge. 40 S & F, installation, commissioning and testing Junction boxes made of Lid PC and base is polystyrene Hensel reference : KG series suitable . Junction Boxes Size 217 x 253 x 115 mm in Grey RAL 7035 colour. Junction Box IP 65 Thermoplastic PS Polystyrene weatherproof Junction Box with multi level knockouts for cable glands in different sizes. The pre-moulded knockouts shall be available on top and bottom of the junction box to enable cable entries from both direction. The junction box shall have an optional cable entry at the bottom up Cable Size 25 Sq mm of the box via pre-moulded knockout to enable pole mounting option. Lid fasteners self closedwill be tool operated. it will be sealable with accessories. The junction box shall have elongated holes inside them for wall/pole mounting provision. The junction box with 4 Pole Terminal Strip and MCB SP 6 Amp 10 KA C Curve for LED light. In the event of formation of condensed water, the junction box shall have a minimum of two condensation knock-outs inside to ensure optimum safe performance. 41 The junction box shall fulfill the following standardsWeatherproof : Rainwater proof, temperature resistant.IEC 60670-22 : Particular requirements for connecting boxes and enclosures.IEC 60695 – 2 – 11 : Flame – retardant & Self-extinguishing. Glow Wire tested at minimum 750 deg C.IEC 60529 : IP 65 degree of protection.UV Resistant in accordance with IEC 61 439-1, Clause no 8.4.4The Junction Box with Suitable Glands 3 Nos with each andchromium plated clamps, nut bolts complete all as per manufacturer’s instructions. 42 Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (Main LT Panel )INCOMING:(a) Aluminium bus bar 3 phase 4 strip suitable for 600 Amps current carrying capacitycomplete with post insulators and heat shrinkable sleeves- 01 No.(b) MCB TPN, 415 V, 10 KA, with Thermal Magnetic Release of capacity 16 Amps - 01 No Incomer 43 OUTGOING:(c) MCB TPN, 415 V, 10 KA, with Thermal Magnetic Release of capacity 10 Amps - 02 Nos O/G(d) Indicator Lamp LED type (RYB) - 01 Set (e) Digital type Ammeter 3 Ph with in built selector switchsuitable up to 100 Amp including suitable rating CTs -01 Set(f) Digital type Voltmeter 3 Ph with in built selector switchsuitable up to 500 Volt- 01 Set(g) All accessories prewired with appropriate size copper strip or wire thimbles etc.(h) All as required including foundations as per Manufacturers recommendations as directed by Engr-in-Charge. 44 Supply & installation of silent CPCB4 approved 625 KVA TPDiesel Generating Set having diesel engine Liquid cooled, Electric start, four stroke, cold starting, TCI Aspirated, compression ignition, totally enclosed diesel engine with electronic governor , direct coupled ith 625 KVA Three Phase alternator at 1500 RPM, 0.8 lagging power factor, providing Three Phase 415Volts suitable for 50 Hz, H class insulated winding, Close-direct-coupled, Self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel base-frame. The alternator shall confirm to IS: 13364, IS: 4722, BS5000, IEC: 34 and suitable for tropical condition. having fitted inside Canopy, fabricated out of 1.6 mm CRCA Sheet, cubical type, totally enclosed, Powder Coated, Control Panel and all accessories in- housed in a acoustic enclosure – sound proof canopy. 45 (A) Diesel Engine: - Adquate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexiable coupling multi cylinder multi stroke direct injection,cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- 46 i) Fly wheel with housingii) Cooling system :- Moulded radiator with fan & belts.iii) Cooling Water pump : - Centrifugal type belt driven.iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclousre. Exhaust gas turbo charger type, Exhaust manifold, Silecer : Residual type, Bellows 47 iv) Fule System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governer for 1% speed /frequecy regulation. Fuel filters, Fuel hosesv) Lub oil System :-Lubricating oil filter, Lubricating oil pumpvi) Air Intake System :- Air intake Manifold, Air cleanler dry type, vii) Governer :- Electronic Governer, viii) Starting System :- Electric Self starter with maintenace free battary including battary charging alternator. 48 (B) Batteries :- 24 VDC system 2x180 AH Batteries of maintenece free of capacity as recommended by the manufacturer complete with copper conductor multistrnded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified of Make as per OEM.D) Starter gear ring, Start and stop push button, Ignition key / Switch, Handling and operation : Salient features of accessories shall be as under, Radiator with blower fan, Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass. Electronic governer controlled direct fuel injection system, Fly wheel housing and fly wheel. 49 (C) Generator Monitoring Control Panel : - Comprising of all standard items as mentioned under this schedule or as per standardpractice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display including suitable size MCCBs and multifuction meter.xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine.xii) Coupling arrngement : - Flexiable coupling, fly wheel to suit flexiable coupling. 50 xiii) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames.xiv) Base Frame with anti vibration pads on base frame: - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes.xv) MS pipe line to and from the fuel tank to the DG Set.(D) Alternator :-Standard design alternator rated at 625 KVA,net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC,3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class H and voltage regulation of+ 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be inposition to generate supply with frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. 51 i) Insualation class - H, ii) Temparature rise Class - H, iii) Excitation : Self Excited, iv) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5% . v) Frequency regulation + 1%F). Civil Works :- All civil works including PCC plat form as per manufactures design also 30 cm above the ground. The depth of the foundation and PCC as recommended by the manufacturer. G) Rubber Mattingof LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel should be provided.Note:- The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. 52 (E) Accoustic Enclosure:- Manufactured by OEM suitable for 625 KVA DG Set. (i) NAL approved as per CPCB(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.(iii) The generating setbattaries and control panel should be inside the enclosure.(iv) Fuel tank should be out side the enclosure in the sub station building.v) The DG Set should be provided with external Emergency stop push button.vi) The battaries should be placed inside the enclosure beside the DG Set on a suitable inlsulatedplatform.viii) The enclosure should be suitably illuminated by suitable capacity of LEDfittings.xi) The noise level should be 75 db at 1m under free field conditions. 53 xii) The accoustic enclosure parts shall be of powder coated after pre treat ment process. The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade.xiii) Fuel tank as per manufacturer recommendation with inlet and outler connections and fuel level indicator.NOTE : - (i) TheGenerator set prime mover will produce at least 734 BHP on 625 KVA.(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to distrbed surfaces so as to match with the existing finishes all as specified and directed.(iii) The quoted rate shall be deemed to be inclusive of first filling of lubricant oil. (iv) The quoted rate shall be deemed to be inclusive of 24 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by accepting Officer; including FOL, all arrangements are to be made by the contractor for tests. 54 Supply and fix off LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 1000 Amps complete all as specified and directed. 55 Supply and fixing LED blub full dum 7 watt with rechargeble type, retrofit all as specified and directed by Engr-in-charge 56 S&F Double door three phase prewired distribution board vertical DB TPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 100 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately) 57 S&F Double door three phase prewired distribution board vertical DB TPN 4 way with acrylic door made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar 200 Amps, 415 V,IP 43/IK09, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 200 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately) 58 S&F LED building security light, pressure die cast aluminum housing, 20/25 watts capacity, toughned glass, 240V, IP 66 class, impact resistence IK07, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 5 mtr from groundwith MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as directed and specified by Engr-in-Charge. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 59 Supply and Fixing of 40W LED High Bay light with Surface mounted device(SMD) with multiple LED with Borosilicate glass lens and acrylic, with aluminum reflector,operating Voltage between 140-270Vac, Power Factor more than 0.95%, intergal driver with 3KV surge protection differential mode/coman mode ,LED CCT 5665±355K as per ANSI BIN, Over load protection,No load Protection, Driver should be concealed under IP66 and BIS Marking (R no. for Driver), Driver Certiifcation IEC64347-2-13 IS(15885), System Lumen >4000, CRI>70, Over all electrical efficency more than 90%,connecting with PVC copper cable of size 3x1 sqmm at least 2 Year on site warranty wihout any condition including taking down of old light fitting safely and removing from site complete all as specified and directed. 60 SCH A PART - XIV(HOT WATER SUPPLY)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 61 Supply and fixing of 5 star rated Water Heaters Storage type (Geysers) of Capacity 25 ltrs including grouting the nuts, bolts, washers of adequate size and all other accessories required at site for the effective functioning of the water heater complete all as specified and directed.Note :(i) Cost of Stop cocks deemed to be included in the quoted rate no extra payment shall be made.(ii) PVC connections, Bib cock and GI pipe shall be measured and paid seperately. 62 S&F BIB TAPS, chromim plated cast copper alloy with capstain head, screwed for 20mm bore dia iron pipes or for brass ferruble and fixed complete all specified and directed. 63 S&F PVC connection 15mm dia with PTMT nuts of length 450mm complete all as specified and directed. 64 SCH A PART - XV(CENTRAL HEATING SYSTEM)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 5 signifies this fact only 65 Electric Hot Water Generator : Supply, installation, testing and commissioning ofpackage type electric Hot Water generator constructed out of MS sheet having top open-able cover for easy access and removal of heaters. The HWG shall be suitable for indoor mounting. The generator shall be provided with 50mm thick fibre glass insulation 32 kg density finished with 0.8mm / 22G aluminium cladding sheet. The generator shall have electrical capacity of 150 kW. The heater shall be electrical resistance type, copper tube with chromium plating. The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, etc. The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply. The generator shall complete with self-contained incoming isolation, ammeter, voltmeter, contactors for heater banks in three steps complete with manual/auto rotary switches. 66 (a) All neccassary accessories required for the proper fucntioning of Hot Water Genearator are included in price.(b) The prices should include lifting, shifting and positioning of units at Site.(c) Hot Water Genearator installation to done as per Manufacturer recommendation with all installation requirements i.e Foundation, Vibration Isolator,Insulationetc as recommended by Manufacturer for the Ambient Temperature of Site. ODU installation is included in ODU price which includes the Civil Struture, Mechanical Structureetc as recommended byManufacturer. (d) The Contractor/OEM will shall submit the Hot Water Generator capacity/Burner Capacity as per ISO or equivalent standard.(e) OEM should submit the Installation and Maintenance Schedule/ Manual for the Boiler. 67 GLYCOL CIRCULATION CENTRIFUGAL PUMPS: Supply, Installation, Testing & Commissioning of PN16 ratedAxial Split Coupled Vertical Inline water pump set with CI casing, Bronze Impeller, SS Shaft and externally flushed outside type balanced mechanical seal and non overloading motor, as per specifications and drawings. with Suitable HP, TEFC squirrel cage induction motor with EFF1 type class F insulation, Motor shall be rating of IP 55, operating on 415 ±10% volts, 3 phase, 50Hz AC Supply. The external flush line must be used for the purpose of heat dissipation from the mechanical seal.Pumps with performance characteristics as given below: The internal components of pumps including mechanical seal shall be suitable to sustain a fluid temperature of -25 Degree Celcius to 120 Degree Celcius. Vendor shall be provide antivibration arrangement for pumps . 68 The scope also shall include following below mentioned:(i) Electrical by pass starter for pump setas recommended by OEM.(ii) 25 mm thick polyviny nitrile rubber insulation duly cladded between aluminium sheets of 0.5mm thickness and properly clamped to pump.(iii) 3 Nos.- 150 mm dia type pressure gauges(iv) Mounting frame with antivibration pads (In case pumps are inline, anti vibration system shall be as per Manufacturers recommendation)(v) RCC/Cement concrete foundation for the pump unit. (In case pumps are inline, foundation shall be as per Manufacturers recommendation). (vi) Pump capacity are as under:(vii) Capacityand pump headnot less than flow 350 USGPM , Head 35 mtr each including the triple duct valve and End Suction guide. Note:- In 02 Nos working and 01 No standby configuration. 69 EXPANSION TANK and Pressurisation Unit: Supply, Installation, Testing and commissioning of INSULATED PRESSURISED CLOSED WATER EXPANSION TANK suitable for total volume ofGlycol - Water Solution, circuit along with necessary accessories such as along with necessary accessories such as 2 Nos pumps (1working +1standby) with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc.with Pressure Transmitter andinterconnecting Pipe & Isolating Valve complete with piping connections, safety relief valve, drain valve, pressure gauge, automatic air purging arrangement, etc. The tank shall be pre-charged. Expansion tank Shall be with replaceable heavy duty butyl rubber bladder. 70 The tankconnections should be as per OEM recommendationsand 20 mm drain and charging valve connection to facilitate the on site charging of nitrogen in the tank.The tank shall be fitted with lifting rings and a floor mounting skirt for vertical installation. The tank must be constructed in accordance with IS-STANDARD 2825-1969 (withlates Revision)and Rated at PN 16 and ASME Stamped. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system. 71 The tank shall be duly painted in approved colour shall be complete with pressure switches and power distribution and control panelIP55 Control Panel, Pressure Transmitter, interconnecting piping & wiring. (Tank capacity 1000 Ltrs). Hot Glycol - Water closed vessel pressurized expansion tank as described above shall be duly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material or Equivalent U valueInsulating Material and cladded with aluminium Sheet (20G). 72 (a)Expansion Tank of 1000 Lts capacity for bldg 73 (b)PRESSURIZATION UNIT: for Pump Set -03 Nos (Ref. Point 4) with Control Panel and accessories for bldg. 74 Make Up TANK: Supply, installation, testing and commissioning of factory made Make up Water Tank, Rectangular/Circular shape, of 4 mm thick MS sheet (IS 2062), of capacity of 990 litres for Pocket-1complete with inlet, outlet, overflow, drain pipe of MS and vent with flame arrestor. Tank will be provided with supports made out of minimum 50mm angle iron duly painted, to keep tank base at minimum (1000mm) above FFL. Service platform shall be provided as per recommendations of OEM. The tank shall be provided with remote indication of levels provided level switches for on-off operation of tranfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.Make up Water tank as describedabove should beduly Insulated with 50 mm thick PUF/Nitrile Rubber insulating material and cladded with aluminium Sheet (20G). 75 Supply, Installation, Testing and Commissioning ofCeiling Suspended Fan Coil Unit having casing with bottom return Air Plenum complete including Direct driven fan (three speed) motor, operated on 230 volts, single phase, 50Hz, AC supply. Unit to be provided with inbulit 2way wall withcordless remote. The Ball Valve with Strainer/ Shut off Value with Strainer at inlet and outlet of FCU including copper connection pipe for inlet and outlet should be provided. The Unit Capacityshould becalculated as per BIS/ Eurovent Standard/AHRI Certification method.The below desired capacity should be calculated at Altitude of 3600 mts above sea level. Capacity calculation sheet to be provided to Engineer in Charge. The below mentioned capacity is at INLET TEMP: 65 Degree Celcius , OUTLET TEMP: 55 Degree Celcius and Below Mention External Static Pressure (ESP). 76 2.5 kW,ESP: 50 Pa (Reference Model No.:FWW200VC / Equivalent)(CHS Plant Room - Toilet ) 77 5 kW,ESP: 50 Pa (Reference Model No.:FWW500VC/Equivalent) (Wkshp Toilet Area - 4 Qty, CHS Plant Room - Toilet- 1 Qty) 78 10kW,ESP: 50 Pa ( Reference Model No.:FWW1000VC/Equivalent)(Staff Room: 2 Qty, SPL Shop, Tech TRG, Tech LIB, Inspection OFF, Office for Wksh- 1 Qty 79 12 kW,ESP: 100 Pa( Reference Model No.:FUW015A/Equivalent)(Electricain - 1 Qty) 80 18kW,ESP: 100 Pa ( Reference Model No.:FUW020A/Equivalent)(Office for QC n Fuel Injection - 1 Qty) 81 24 kW,ESP: 100 Pa( Reference Model No.:FUW030A/Equivalent)(Mech Section- 1 Qty) 82 30kW,ESP: 100 Pa (Reference Model No.:FUW035A/Equivalent)(Service Bay - 2 Qty Each Service Bay) 83 M & L for Pre - insulated MS pipe,Class C havingminimum thicknes of PUF insulation as mentioned below and of density 36 Kg/Cum and 26 gauge GI/AL cladding complete suitable for above ground as per sizes shown.The pipes should be insulated with closed cell puf of density 36±2 Kg/Cum of below mentioned thickness. The Pipe should be workable in the temp. range of-50 Degree Celciusto120 Degreec Celcius. Note:-The Pipes size 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 84 Inside Building 85 100 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 86 80 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 87 65 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 88 50 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 89 40 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 90 20 mm with 36 mm PUF thicknes and 26 Gauge Al Cladding. 91 Buried under ground/Exposed to Ambient: 92 100 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 93 80 mm with 50 mm PUF thicknes and HDPE Cladding, 26 Gauge Al Cladding. 94 Supply,Installation, Testing amd commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows,tees, reducers,sockets,u trap etc.) supports, jointinginsulated with XLPE class O tubular insulation and any other item required to make the system compelete. Nominal diameters of pipein mms as inducated below: 95 25 mm dia pipe, Insulation thickness - 19 mm 96 32 mm dia pipe, Insulation thickness - 19 mm 97 40 mm dia pipe, Insulation thickness - 19 mm 98 CABLE TRAYS 99 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/Ground/wall with M.S. suspenders including bolts & nuts, painting suspenders etc. as required 100 150 mm width X 50 mm depth X 1.6 mm thickness 101 VALVES : 102 Supplying, fixing, testing and commissioning of following diameter valves(PN-16 Rating) (Complete with Flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), strainers (Complete with flanges integral or welded, fittings, Nuts, Bolts & Gaskets (PN-16 Rating), gauges etc for condenser water circulation as per specifications. Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified.Butterfly Valve ( Insulated Valves) with CI body SS disc nitrile sheet & O ring, Complete with fittings, Nuts, Bolts & Gaskets. 103 100 mm dia Butterfly Valve 104 65 mm dia Butterfly Valve 105 Y - STRAINER (Insulated Valves) of Ductile CI Body flanged ends with stainless steel strainer forhot water circulation including Insulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as specified. 106 65 mm dia Y STRAINER 107 NON - RETURN VALVE (Insulated Valves) with duel plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating forhot water circulation includingInsulation thickness ofvalves should be equal to the Insulation of PUF and GI Cladding of Pipe Section as sepcified. 108 65 mm dia NRV 109 Automatic Air Purge Valves forhot water circulation headeras specified and required by Engineer In Charge. 110 Automtic Air Purge Valve 20 mmdia 111 Air Separator (PN16) 112 65 mm 113 SITC of water pressure gauge (100 mm dia) bourdon type with brass ball valve of 3/8 dia and SS tubing, socket.Range (0-50) / (0-100) as required by Engineer In Charge. 114 SITC of Mercury in glass industrial thermometer in SS-304 casing with 0.5 C least count, range 0-50 C. Brass oil filled thermowell of 1/2 size as required by Engineer In Charge. 115 Supply, installation, commissioning and testing of factory made, CPRI approved LTCHS Plant, indoor type made out of CRCA sheet 2 mm thick, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, floor mounted and grounting the legs of panel in PCC foundation 1:4:8 complete as all directed suitable for and including the following :- As per IE rule and latest is, necessary colour coding for R, Y, B and N shall be made with different colour as per IE rule. 116 INCOMERS(a) Bus Bar TPN Copper extensible type main bus bars of minimum of1200 A capacity (As per capacity of corresponding incoming / Bus couplers) , and auxilliary bus bars ofsuitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of50kA .(b)ACB 800 Amps, 415 Volt, 50 KA, 4 Pole, thermal magnetic release - 01 No for incoming (Extended Rotary Operating Handle, Phase Spreader links and Phase barriers) Make: Legrand/Schenider/Simens 117 OUTGOINGS(c) 4 Nos- 400A 10 KA TPNMCCBwith Microprocessor release (3# Hot Water Generator) (d) MCB 5/6 Amp, 10KA, TPN - 02NosPressurization PUMPs (e) MCB 50 Amp, 10KA, TPN - 03 Nos for Pumps(f) MCB 5/6 Amp, 10KA, SPN,- 07No for Bldg load/FCU. Makes of MCBs: Legrand/Schenider/Simens(g) LED Phase indication lamps (01 Set) with 2Amp back up MCB,Breaker ON/OFF indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. - 2 Set 118 (h) Digital Ammeter with in built ASS,metering C.T.sCAST RESIN type, 15VA, and accuracy class-1of 800/5A for measuring current in each phase - 01 Set.(j) All accessories prewired with appropriate size copper strip or wire and thimbles etc. all as required including foundations as per Manufacturers recommendations all as directed by Engnr-in-Charge.Note : Contractor will submit the drawing of panel to GE before execution for approval. 119 Supply & Laying/ fixing of following size XLPE insulated and PVC sheathed Copper conductor armoured cable/unarmoured as required of 1.1 KV grade complete as required. (ISI Marked) (in ground/in pipe/in duct/on surface/on cable tray) 120 3.5 Core x 250 sq.mm. (Electric Hot Water Generator) 121 4 Core x 10 sq.mm. (Pump) 122 4 Core x 6 sq.mm (Pressurization Unit) 123 2 Single corex 2.5 sq.mm. (FCU) 124 4 Core x 4 sq.mm (Boiler Pump) 125 Earthing complete with GIearth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by light grade 40mm dia upto 7.5 mtr long GI pipe connected to main controlboard and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick and PCC chamber pit with PCC 1:2:4 type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified & directed by Engr-in-charge. 126 Supply and fixing rubber matting conforming to IS-15652-2006 complete as required. of size2m * 1m * 25 mm complete all as specified & directed by Engr-in-charge. 127 Supplying of Ethylene glycol concentrate along with the necessary additives and inhibitor in cognition in sealed barrels for CHS complete all as directed.NOTE;- (i) The glycol concentrate shall be mixed with potable water supplied by contractor and filled in central heating system pipe line after proper leak test of entire circuit. The glycol water mixture ratio shall be 55:45 and freezing temperature shall be - 45 Degree Celcius (ii) First charge of glycol is included in the quoted rate. First Charge Include Charge in CHS pipe lineStorage Tank. 128 GENERAL NOTES:- 129 1. The rate for each item of work included in the Schedule of Quantities shall, unless expressly stated otherwise, include cost of :(a) All materials, fixing materials, accessories, appliances tools, plants, equipment, transport, labour and incidentals required in preparation for and in the full and entire execution, testing, balancing, commissioning and completion of work called for in the item and as per Specifications and Drawings.(b) Wastage on materials and labour.(c) Loading, transporting, unloading, handling/double handling, hoisting to all levels, setting, fitting and fixing in position, protecting, disposal of debris and all other labour necessary in and for the full and entire execution and for the job in accordance with the contract documents, good practice and recognize principles. 130 (d) Liabilities, obligations and risks arising out of Conditions of Contract.(e) The unit rate for all equipment or materials in Indian Rupees shall include cost of equipment and materials including all taxes and duties and also including forwarding, freight, insurance and transport into Contractor’s store at site, storage, installation, testing, balancing, commissioning and other works required.2. The contractor shall perform Nitrogen test and vacuum test on refrigerant piping. Start and stop timing & pressure maintained shall be checked and the readings recorded shall be counter signed by consultant / client’s representative. 131 3. Cable glands shall be compression type, heavy-duty chromium plated.4. All cable termination to have lugs/ thimbles.5. INSTRUCTION / MAINTENANCE MANUAL 132 The Contractor shall prepare and produce instruction, operation and maintenance manuals in English for the use, operation and the maintenance of the supplied equipment and installations and submit to the Client / Consultant in (3) copies at the time of handing over. The manual shallgenerally consist of the following:(i) Description of the project.(ii) Operatinginstructions.(iii)Maintenance instructions including procedures for preventive maintenance.(iv) Manufacturers catalogues.(v) Trouble shooting charts.(vi) Schematic & control wiring diagrams. 133 (vii) Commissioning Certificate.(viii) Also for BMS System, Training,Opeartion, Installation manual and Trouble shooting manual and Training should be imparted to the field person.(ix) Allneccassary license should be provided for the BMS free of cost.6. For Make List If any make stated below does not comply with the technical specifications and or IS Standards then such a make shall not be used in the work. 7.MAINTENANCE OF PLANT AND TRAINING OF PERSONNELThe Cont ractor shall arrange to provide, at no extra cost, necessary personnel and material to carry out all routine maintenance of the CHS equipment as required regularly.
Contract Date: Sep 30, 2025 Contract Value : 10.47 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
39.
Rural Development #7955297 AOC
Tender For Liquid Waste Management Scheme At Mhasdi Pr Ner Tal Sakri - Liquid Waste Management -Sub Work 1 - 10 KLD Public Leach Pit Item No 1 - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 2 Item No 1 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 3 Item No 1 - Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) 0 to 1.5 m 4 Item No 2 :- Providing and laying in situ Cement Concrete M- 15 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38. 5 Item No 3 - Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 6 Item No 4 - Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Item No 5 - Providing and casting in situ C.C. of trap / granite/ quartzite /gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 8 Item No 6 - Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 9 Item NO 7 - Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 0.90 X 0.60 10 Item No 8 - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification по. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 11 Sub Work 2 - 125 KLD CAMUS SBT Sewage Treatment Plant Item No 1 - Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering. preparing the bed for foundation and excluding backfilling, etc complete. (BdA1/259) 0.0 to 1.5 m 12 1.5 to 3.0 m 13 3.0 to 4.5 m 14 Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259) 0.0 to 1.5 m 15 1.5 to 3.0 m 16 3.0 to 4.5 m 17 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259) 0.0 to 1.5 m 18 1.5 to 3.0 m 19 3.0 to 4.5 m 20 Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering. excluding backfilling, etc. complete by all means. (BdA6/259) 0.0 to 1.5 m 21 1.5 to 3.0 m 22 3.0 to 4.5 m 23 Providing dry trap/granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264) 24 Providing and laying in situ Cement Concrete M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. Bd E /1 Page No. 287 and B 7,for Beam/Braces/Lintels in PCC 25 Providing and layingin situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 26 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 27 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 28 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas/Parapets/Curtains Walls / Partition Walls/Pardies in RCC M 300 29 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) 30 Providing and fixing mild steel grill work for windows/ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) 31 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 32 Providing and applying whitewash in two coats on old/new plastered or masonry surfaces and asbestos cernent sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 33 Providing and applying colourwash of approved colour and shade in 136.95 one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc, complete. 34 Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc, complete. (BdA9/261 35 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 36 Transportation as per STATEMENT VI Including loading, unloading and stacking Screen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bend Quotation Item Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 37 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 38 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 9000 LPH Supply 39 2 HP upto 9000 LPH Erection 40 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 12000 LPH Supply 41 2 HP upto 12000 LPH Erection 42 NaOCI Chlorinator Pump Diaphragm Type/peristaltic type / Solenoid Max Flow Power source Eletric Phases Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 Nos Quotation Item Designing, Supplying, Installing, commissioning & testing of PLC Panel Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. Control Panel 43 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 44 Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 7.5 HP & upto 12.5 HP 45 Erection 46 Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core16sqm supply 47 Erection 48 Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/ on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 2.5 sqm mm supply 49 Erection 50 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Unarmoured control cable with ISI mark stranded/solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner 4 Core 2.5 sqm mm supply 51 Erection 52 Piumbing Item - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material l.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). Raw Sewage pump to10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates CAMUS Distribution Main header 75 mm 53 PVC Specials 54 Distribution 63 mm 55 PVC Specials 56 CAMUS Collection 75 mm 57 PVC Specials 58 Collection tributory 63 mm 59 PVC Specials 60 CAMUS Distribution 63 mm 61 PVC Specials 62 Plumber 63 Helper 64 Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass) Raw Sewage pump 80 mm 65 Providing and supplying ISI mark CI D/F reflux valves (non return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.5.5312 Part I (1984) Without by pass arrangement PN 1 Raw Sewage pump 66 Providing, laying, spreading in layers stone aggregates of specific size as a Bio media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. complete Supplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 67 As Per Rate Analysis Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including 3.0 conveying & stacking 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 68 Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd 69 Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete 70 Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness). (As per P&G DSR 2022-23 Items of garden work, Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR required variety of lawn (free from weeds / diesease etc.) Cynadon/paspalum/selection for 1 sqm. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work, Sr No.46) 71 Excavation for planting lawn/shrub/flower bed/hedges/ edges/canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.3), Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.13), Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flower bed/ hedges/edges/canna bed/ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work, Sr No.23), Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/selection) (As per P&G DSR 2022-23 Items of garden work, Sr No.28) 72 Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,. Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018 73 Providing Energy Meter Application Fees Energy Meter Fee
Contract Date: Sep 16, 2025 Contract Value : 4.62 Lakh
Government Departments No of Bidders 1
Maharashtra View Result →
40.
Rural Development #7955294 AOC
Tender For Liquid Waste Management Scheme Nimgul Tal Shindkheda Dist Dhule - Liquid Waste Management -Sub Work 1 - 10 KLD Public Leach Pit Item No 1 - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 2 Item No 1 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 3 Item No 1 - Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) 0 to 1.5 m 4 Item No 2 :- Providing and laying in situ Cement Concrete M- 15 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38. 5 Item No 3 - Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 6 Item No 4 - Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Item No 5 - Providing and casting in situ C.C. of trap / granite/ quartzite /gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 8 Item No 6 - Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 9 Item NO 7 - Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 0.90 X 0.60 10 Item No 8 - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification по. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 11 Sub Work 2 - 50 KLD CAMUS SBT Sewage Treatment Plant Item No 1 - Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering. preparing the bed for foundation and excluding backfilling, etc complete. (BdA1/259) 0.0 to 1.5 m 12 1.5 to 3.0 m 13 3.0 to 4.5 m 14 Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259) 0.0 to 1.5 m 15 1.5 to 3.0 m 16 3.0 to 4.5 m 17 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259) 0.0 to 1.5 m 18 1.5 to 3.0 m 19 3.0 to 4.5 m 20 Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering. excluding backfilling, etc. complete by all means. (BdA6/259) 0.0 to 1.5 m 21 1.5 to 3.0 m 22 3.0 to 4.5 m 23 Providing dry trap/granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264) 24 Providing and laying in situ Cement Concrete M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. Bd E /1 Page No. 287 and B 7,for Beam/Braces/Lintels in PCC 25 Providing and layingin situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 26 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 27 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 28 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas/Parapets/Curtains Walls / Partition Walls/Pardies in RCC M 300 29 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) 30 Providing and fixing mild steel grill work for windows/ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) 31 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 32 Providing and applying whitewash in two coats on old/new plastered or masonry surfaces and asbestos cernent sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 33 Providing and applying colourwash of approved colour and shade in 136.95 one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc, complete. 34 Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc, complete. (BdA9/261 35 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 36 Transportation as per STATEMENT VI Including loading, unloading and stacking Screen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bend Quotation Item Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 37 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 38 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 9000 LPH Supply 39 2 HP upto 9000 LPH Erection 40 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 12000 LPH Supply 41 2 HP upto 12000 LPH Erection 42 NaOCI Chlorinator Pump Diaphragm Type/peristaltic type / Solenoid Max Flow Power source Eletric Phases Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 Nos Quotation Item Designing, Supplying, Installing, commissioning & testing of PLC Panel Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. Control Panel 43 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 44 Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 7.5 HP & upto 12.5 HP 45 Erection 46 Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core16sqm supply 47 Erection 48 Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/ on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 2.5 sqm mm supply 49 Erection 50 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Unarmoured control cable with ISI mark stranded/solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner 4 Core 2.5 sqm mm supply 51 Erection 52 Piumbing Item - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material l.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). Raw Sewage pump to10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates CAMUS Distribution Main header 75 mm 53 PVC Specials 54 Distribution 63 mm 55 PVC Specials 56 CAMUS Collection 75 mm 57 PVC Specials 58 Collection tributory 63 mm 59 PVC Specials 60 CAMUS Distribution 63 mm 61 PVC Specials 62 Plumber 63 Helper 64 Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass) Raw Sewage pump 80 mm 65 Providing and supplying ISI mark CI D/F reflux valves (non return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.5.5312 Part I (1984) Without by pass arrangement PN 1 Raw Sewage pump 66 Providing, laying, spreading in layers stone aggregates of specific size as a Bio media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. complete Supplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 67 As Per Rate Analysis Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including 3.0 conveying & stacking 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 68 Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd 69 Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete 70 Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness). (As per P&G DSR 2022-23 Items of garden work, Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR required variety of lawn (free from weeds / diesease etc.) Cynadon/paspalum/selection for 1 sqm. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work, Sr No.46) 71 Excavation for planting lawn/shrub/flower bed/hedges/ edges/canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.3), Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.13), Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flower bed/ hedges/edges/canna bed/ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work, Sr No.23), Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/selection) (As per P&G DSR 2022-23 Items of garden work, Sr No.28) 72 Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,. Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018 73 Providing Energy Meter Application Fees Energy Meter Fee
Contract Date: Sep 16, 2025 Contract Value : 32.25 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
41.
Rural Development #7955293 AOC
Tender for Liquid Waste Management Scheme Varshi Tal Shindkheda Dist Dhule - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259) 2 Item No 1 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-3/259) 3 Item No 1 - Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 4/259) 0 to 1.5 m 4 Item No 2 :- Providing and laying in situ Cement Concrete M- 15 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) Spec. No. - Bd E /1 Page No. 287 and B-7, Page No. 38. 5 Item No 3 - Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:4 including scaffolding, racking out joints and watering etc. in pillar of rectangular shapes as shown in the drawings or as directed complete. 6 Item No 4 - Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. 7 Item No 5 - Providing and casting in situ C.C. of trap / granite/ quartzite /gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in- charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) 8 Item No 6 - Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F-17/306) 9 Item NO 7 - Providing and fixing in position steel fibre reinforced concrete (S.F.R.C.) frame and covers of approved make including loading, unloading, transportation, all taxes, etc. complete as directed by Engineer in charge (20 tonnes capacity). 0.90 X 0.60 10 Item No 8 - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification по. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 11 Sub Work 2 - 50 KLD CAMUS SBT Sewage Treatment Plant Item No 1 - Excavation for foundation/pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering. preparing the bed for foundation and excluding backfilling, etc complete. (BdA1/259) 0.0 to 1.5 m 12 1.5 to 3.0 m 13 3.0 to 4.5 m 14 Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA3/259) 0.0 to 1.5 m 15 1.5 to 3.0 m 16 3.0 to 4.5 m 17 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA 4/259) 0.0 to 1.5 m 18 1.5 to 3.0 m 19 3.0 to 4.5 m 20 Excavation for foundation/pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineerincharge, normal dewatering. excluding backfilling, etc. complete by all means. (BdA6/259) 0.0 to 1.5 m 21 1.5 to 3.0 m 22 3.0 to 4.5 m 23 Providing dry trap/granite/quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (BdA12/264) 24 Providing and laying in situ Cement Concrete M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum) Spec. No. Bd E /1 Page No. 287 and B 7,for Beam/Braces/Lintels in PCC 25 Providing and layingin situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 26 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 27 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs/Landings/vertical Walls/Waist Slabs/Steps for Staircase in RCC M300 28 Providing and Casting in situ C.C. of trap/granite/quartizite/gneiss metal of approved quality for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)Chajjas/Parapets/Curtains Walls / Partition Walls/Pardies in RCC M 300 29 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (BdF17/306) 30 Providing and fixing mild steel grill work for windows/ventilators of 20 Kg/Sqm. As per drawings including necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting, etc. complete. (BdU1/537) 31 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12 mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curing complete. 32 Providing and applying whitewash in two coats on old/new plastered or masonry surfaces and asbestos cernent sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. 33 Providing and applying colourwash of approved colour and shade in 136.95 one coat to new surface including scaffolding, brushing and brooming down (excluding base coats of white wash) etc, complete. 34 Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineerincharge (including cost of machinery, labour, fuel), etc, complete. (BdA9/261 35 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. 36 Transportation as per STATEMENT VI Including loading, unloading and stacking Screen (Manual) of size 1.6 m length x 0.5 m width of SS 304 MOC and Manual hand rake for cleaning screen of SS handle 1 m in length and cleaning area of 6 nos 5 mm SS rod of total length 200mm straight and 50mm of 90 degree bend Quotation Item Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below 37 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 38 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 9000 LPH Supply 39 2 HP upto 9000 LPH Erection 40 Supplying Nonclog Submersible Pump suitable for sewage/ Liquid waste application with standard MOC and given duty points as below raw sewage pumps 2 HP upto 12000 LPH Supply 41 2 HP upto 12000 LPH Erection 42 NaOCI Chlorinator Pump Diaphragm Type/peristaltic type / Solenoid Max Flow Power source Eletric Phases Single Material PP/PTFE (Teflon) Voltage 230 Volt Frequency 50Hz Mixing Tank of 100 Ltrs capacity 1 No Dosing Pump 2 Nos Quotation Item Designing, Supplying, Installing, commissioning & testing of PLC Panel Including PLC with CPU & Power supply unit, power supplyb cables interfacing cards, interfacing cables, wireless modules with 25% extra quantity of all accessories. Control Panel 43 Screen Manual of Size 1.6 m length x 0.5 m wodth of 55 304 MOC and Manual hand rake of for cleaning screen of 55 handle 1 m in length and cleanig area of 6 nos 5 mm 55 rod of total length 200mm straight and 50 mm to 90 degree bend quotation item , etc. complete. 44 Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. 7.5 HP & upto 12.5 HP 45 Erection 46 Main power supply cable 3 core PVC insulated, PVC sheathed copper conductor flat submersible cable. Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. 3 core16sqm supply 47 Erection 48 Supplying and erecting, XLPE/PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall/ on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.4 Core 2.5 sqm mm supply 49 Erection 50 Copper conductor PVC insulated, Unarmoured control cable Supplying and erecting Unarmoured control cable with ISI mark stranded/solid copper conductor 1.1 kV grade complete erected on wall/panel or in provided trench in an approved manner 4 Core 2.5 sqm mm supply 51 Erection 52 Piumbing Item - Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material l.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). Raw Sewage pump to10% of cost of pipes shall be considered for cost of PVC specials for estimate purpose only. One coupler and required cement solvent shall be provided with each full length pipe cost of which is included in rates CAMUS Distribution Main header 75 mm 53 PVC Specials 54 Distribution 63 mm 55 PVC Specials 56 CAMUS Collection 75 mm 57 PVC Specials 58 Collection tributory 63 mm 59 PVC Specials 60 CAMUS Distribution 63 mm 61 PVC Specials 62 Plumber 63 Helper 64 Providing double flange sluice valve confirming for IS 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete. Sluice valves PN 1 (Without by pass) Raw Sewage pump 80 mm 65 Providing and supplying ISI mark CI D/F reflux valves (non return valves) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per 1.5.5312 Part I (1984) Without by pass arrangement PN 1 Raw Sewage pump 66 Providing, laying, spreading in layers stone aggregates of specific size as a Bio media filter material as specified and directed by technology provider including all labour, material, loading, unloading, transportation, upto 15 Km. lead, placing the bio media in bio reactor including all taxes and duties such as royalty...etc. complete Supplying crushed metal 60 to 80 mm of trap/granite/quartzite/gneiss stone metal at the site including conveying & stacking. 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 67 As Per Rate Analysis Supplying crushed metal 20mm of trap/granite/quartzite/gneiss stone metal at the site including 3.0 conveying & stacking 15 Km Lead. Also Laying into Bio Mound Tank as directed by Vision Earthcare Pvt Ltd. 68 Supplying 40 to 60mm of Hard Murrum at the site including cleaning and laying into Bio Mounds as directed by Vision Earthcare Pvt Ltd 69 Providing and fixing Jute Kanthan (Tarat) sceen to the scaffolding for external guniting as directed including removing the work is over etc.complete 70 Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms. (consolidated thickness). (As per P&G DSR 2022-23 Items of garden work, Sr No.36a), Supplying on site well decomposed Farmyard Manure for excavation area of depth of 30 cms. (Consolidated thickness). (As per P&G DSR required variety of lawn (free from weeds / diesease etc.) Cynadon/paspalum/selection for 1 sqm. area dibbling distance 5 cms. apart c/c. (As per P&G DSR 2022-23 Items of garden work, Sr No.46) 71 Excavation for planting lawn/shrub/flower bed/hedges/ edges/canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.3), Filling fresh garden soil / silt & manure in excavated area of depth 30cms. (As per P&G DSR 2022-23 Items of garden work, Sr No.13), Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/shrub/flower bed/ hedges/edges/canna bed/ground cover. (1/10 of semiskilled labour) (As per P&G DSR 2022-23 Items of garden work, Sr No.23), Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/selection) (As per P&G DSR 2022-23 Items of garden work, Sr No.28) 72 Providing supplying culture Catalyst & On site demostration as per the M/s Vision Earthcare Pvt Ltd all as specified including MOU with technology expert M/s Vision Earthcare Pvt Ltd CAMUS Patent No 414339 Technology Consultancy Charges (General Arranagement and Hydraulic Flow Diagram Design and Drawings), CAMUS Cultures, CAMUS Catalyst,. Maharashtra GO No. Serial No 2017/Sch No351/UDD33 1 dated 27 Feb 2018 73 Providing Energy Meter Application Fees Energy Meter Fee
Contract Date: Sep 16, 2025 Contract Value : 32.22 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
42.
Defence #7902979 AOC
Tender For Provision Of Def Otm Accommodation & Services For Automotive Regt, Acc&S Under Ge (N) Ahmednagar.; 1 SCH A PART-I TO XII:Note: These schedules are pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only 2 Total amount of Sch ‘A’ Part I (Building & Stuctures) 3 Total amount of Sch ‘A’ Part II (Internal Water supply) 4 Total amount of Sch ‘A’ Part III (Internal Electric Supply) 5 Total amount of Sch A Part-IV (Road, Path & Culverts) 6 Total amount of Sch ‘A’ Part V (Area Drainage) 7 Total amount of Sch ‘A’ Part VI (Sewage Disposal) 8 Total amount of Sch A Part-VII (Hot Water Supply) 9 Total amount of Sch A Part-VIII (External Water Supply) 10 Total amount of Sch A Part-IX (External Electric Supply) 11 Total amount of Sch A Part-X (Rain Water Harvesting) 12 Total amount of Sch A Part-XI (Miscellaneous Building Works) 13 Total amount of Sch A Part-XII (Site clearance, Excavation and Earthwork) 14 SCHEDULE A PART-XIII (MISC B/R ANDE/M WORKS)Note: This schedule is not pre-priced by MES and the rate indicated as Rs 0.00 under Col 6 signifies this fact only. 15 S&F in replacement double door Sheet metal enclosures factory made Vertical DBs 6 way TPN, 415 volts concealed In Wall, protection class IP-42, suitable for fixing of MCBs etc, confirming as per lEC 61439-3, suitable for Flush Mounting and Surface Mounting, with 200 A Copper Busbar, with Neutral bar, earthbar and Cable ties for cable management, fully shrouded neutral bars, prefitted masking sheet etc., complete all as specified and as directed. 16 S&F in replacement double door Sheet metal enclosures factory made DBs 6 way SPN, 240 volts, protection class IP-42, suitable for fixing of MCBs etc, confirming as per lEC 61439-3, suitable for Flush Mounting and Surface Mounting, with 200 A Copper Busbar with Neutral bar, Earthbar and cable ties for cable management, fully shrouded Neutral bars, prefitted masking sheet complete all as specified and as directed. 17 S&F Industrial type ultra slim square profile LED lighting fixture, environmental friendly, energy efficient ready to use pack Industrial type LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed. 18 S&F in replacement energy saving and environmental friendly long life LED street light 35 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP-65 protection and impact resistance of IK07 fixed on wall with Gl pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable sizeof 230V 50 HZ etc complete all as specified and directed. 19 S&F Water cooler electric driven (single phase), having storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour, fully stainless steel having two faucets with Refregerant gas R-134a, complete all as specified and as directed. 20 S&F Voltage stabilizer for automatic operation, single phase, naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA, complete all as specified and as directed. 21 S&F Desert cooler electric driven (single phase) having nominal air flow capacity 4000 CFM per hour (or nearest size) etc. complete all as specified and directed. 22 Supply and install hi wall split AC units indoor/outdoor of Capacity 1.5 Ton complete with cordless remote control unit and with PM 2.5 filter for better indoor air quality with minimum 5 star rating and Efficient & Hyper Tropical Inverter Split AC with Copper and it is equipped with Ecofriendly Refrigerant having 3D air flow, noise level within 34 db, equipped with Indoor/Outdoor, remote etc. complete all as specified and directed. 23 S&F 10 user conventional On site LLDPE septic tank designed to carry sewage and sullage water including compelte excavation and earthwork in any type of strata, PCC 1:4:8 foundation, vent shaft, connection etc., all as per manufacturers instruction; complete all asspecified and directed. 24 S&F PVC Junction box of size 200 x 175 x100mm, IP 66 with hinged door including locking arrangment and MCB SP 6 Amp with necessary nut, bolt et.c and including TPN aluminium bus bar of rating not less than 100 Amp mounted on insulators with suitable holes to provide incoming and outgoing LT cables and street light MCB complete all as specified and directed. 25 S&F HDPE DWC pipe ISI mark of outer dia 50 mm polythylene with smooth internal and profiled external surface for non pressure for protection of under ground cables including coupler at every20 metre interval and bends as required including laying and placing in positiion in trenches/ at locations as directed including levelling of the area before placing, complete all as specified and directed. 26 Supply and fix LED Street light Luminaries 60 watt, with inbuilt surge protection 10 KV, Lumans output 6000 with pressure die-cast aluminium housing with toughtened glass & IP 66 protection and impact resistance IK07 fixed with suitable size of Gl Bracket of length 1.2 Mtr,Clamp,Nut, Bolt and washer, connection and 4 sqmm 2 core aluminium service where over head line existing for connection of street light to over head conductor complete all as specified and directed. 27 Earth work in excavation over areas upto 1.5m depth in any kind of soil by mechanical means (Hydraulic excavator)/ manual means, over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sq.M on plan) including getting out the excavated soil, complete all as specified and as directed 28 Earth work in excavation in any kind of soil by mechanical means (Hydraulic excavator)/ manual means, in foundation trenchesor for shafts, walls, cesspits, manholes, pier holes, laying pipes or pipes or underground cables or foundation of poles / stay assembly, not exceeding 1.5 m in width or 10 Sq.M on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil, complete all as specified. 29 M&L for sweet soil filling in floors or pavings laid in layers n.exc 15cm thick spread levelled and rammedincluding watering complete all as specified and asdirected. 30 Supply only Football Goal post fixed type frame dimension 24x8x4 feet complete all as specified and directed by manufacturers instructions complete all as specified and asdirected.. 31 S&F Basket ball ring with net and fiber board 12mm thick made in one piece, non reflectlve flat front surface fixed in frame with screws complete all as specified and asdirected.
Contract Date: Sep 04, 2025 Contract Value : 6.99 Crore
Statutory Bodies & Commissions/Committees No of Bidders 8
Maharashtra View Result →
43.
Defence #7887386 AOC
Tender For Provn Of 12 X 10 Toilet Block Near Rhq Of Cif(R) Sig Regt Under Age(I) Cif (R); 1 Excavation in trenches in any type of soil n. exc 1.5m wide & n. exc 1.50m in depth for foundations for shafts, wells, cesspits, manholes, pier holes & getting out complete all as specified and directed 2 Material and labour for plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete all as specified and directed. 3 M&L for providing reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concretecomplete all as specified and as directed 4 Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. 5 Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. 6 M&L for providing reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregate) as in column , pillars, piers,posts and strutscomplete all as specified and as directed 7 M & L brick work with subclass ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:6 etc, all as spcified and direcrted. 8 M & L Brick work with sub-class `B bricks,old size straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4, all as spcified and direcrted. 9 M & Lfor 40mm thick damp proof coarsein cement concrete (1:2:4) type B-0(using 12.5 mmgradedstone aggregate) using water proofing compound ,to horizontal or vertical surface including use of necessary form work , complete all as specified 10 M & Lfor providing reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregate) as Beams, cantilevers,bressummers, lintels over1.5m spancomplete all as specified and as directed 11 M&L for providing reinforced cement concrete (design mix) M-25 (using 20mm graded stone aggregate) slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and inshelves and the likecomplete all as specified and as directed 12 M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flatfor rough finished surfaces of concrete etc. 13 M & L Formwork to sides of pillars ,posts, struts, piers, columns and stanchion etc for rough finished surfaces of concrete etc. 14 M & L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams flatfor rough finished surfaces of concrete etc. 15 M & L Form work to soffits of suspended slabs such as roof slab, floor slab and similar work not exceeding 200mm thick for rough finished surfaces of concrete flat complete all as specified and directed.. 16 M & L Form work to edges of RCC roof slab, floor slab and similar work not exceeding 200mm thick for rough finished surfaces of concrete flat complete all as specified and directed.. 17 M&L mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape required including cranking, binding spirally for hooping or column, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm diaor securing with clips, complete all as specified and directed. 18 Material andlabour mild steel TMT bars, 6 to8 mm dia , cut to length, bent to shape required including cranking, binding spirally for hooping or column, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm diaor securing with clips, complete all as specified and directed. 19 Mild steel TMT bars 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including crancking, bendingspirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90 MM dia or securing with clipsall as specified and directed. 20 Rendering 15mm thick cement plaster on stone masonry surfaces or other than fair faces of brick work CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. 21 M&L for preperation of new surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified. 22 M&L for 10 mm thick rendering on fair faces of brick workin cement mortar 1:6 and finished even and smooth without using extra cement, complete all as specified. 23 Material and labour for three coat of white wash on newly plastered surfaces of wall including preparation ofsurfaces complete all as specified and directed 24 Material and Labour for 5mm thick cement plaster in CM (1:4) to ceiling surfaceand finished the surface even and smooth without using extra cement complete all as specified. 25 Material and labour for three coat of white wash on newly plastered surface of ceiling including preparation of ceiling surfaces complete all as specified and directed 26 Material & Labour for Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and includingcement screed bed 10mm thick in cement mortar (1:4) base, complete all as specified. 27 M&L for glazed ceramic coloured designer tiles 450 x 300x 7 mm thick as in Vertical surfaces set and jointed in neat cement slurry and jointed or coloured cement to match etc complete over 10 mm thick rendering in CM 1:3all as specified and directed. 28 M&L for 25mm thick cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate) as in sub floor finished even and rough to receive the topping layer (w/o using extra cement) complete all as specified and directed. 29 M&L 50mm thick PCC(1:2:4)type B-1 (using 20mm graded coarse aggregate) over75mm thick PCC(1:3:6)type C-2 (using 40mm graded coarse aggregate ) laid to an outward slope 1:12 as in plinth protection complete all as specified and directed. 30 Sand filling under floors or in foundationincluding watering and consolidation 31 Material and labour for plain cement concrete 1:5:10 type E-2 (using 40 mm gradedaggregate), as in foundation filling and mass concrete, complete all as specified and directed. 32 Supplyand fixing factory made PVC hollow door frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of extended 5 mm rigid PVC foam sheet cut at corner and jointed with 02 Nos., 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided through out the frame and fixing to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical numberand minimum 02 Nos. for horizontal member), complete all as specified and directed. 33 Supplyand fixing factory made 30 mm PVC rigid foam panel door shutter made from mild steel tubular frame of size 19 mm x 19 mm for stiles and 15 mm x 15 mm for topand bottom rails and covered with 5 mm thick head moulded PVC channel having width of 50 mm to form stilesand PVC street of width 75 mm to form rock rail, bottom railand top rail or either side having panels inserted with 5 mm thick PVC sheet sealed with solvent cement adhesive to the stiles and rails with 5 mm x 25 mm PVC sheet beading on either side including three Nos. aluminium hinges for each door complete all as per manufacturer instructionscomplete all as specified and directed. 34 Supply & fixedaluminium anodized, barrel tower bolts of extruded section 200mm long ISI marked complete all as specified. 35 Supply & fixing300 mmaluminium anodised sliding door bolts, ISI marked, with hasp, staple (bolt type) complete with clamps bolt not less than 16mm dia and fixing clips of sheet, cast or extruded section and fixing bolts an sliding bolt of extruded section or cast aluminium alloy, complete all as specified. 36 Supply & fixed mild steel butt hinges medium weight, cold rolled, 100 mm, ISI marked, complete all as specified. 37 Supply & fixed extruded aluminium alloy handles, fabricated type, anodized 150mm long, complete all as specified. 38 S&F Rotational moulded polyethelyne water storage tank HDPE three layered (cylindrical vertical with closed top hoisted fixed in position all as specified in SSR part-I, capacity of tank 500 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade ,complete all as specified. 39 S&F 20mm Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrulecomplete all as specified. 40 Supply & fixedvitreous china wash hand basin white flat back of size 550x440mm including CI brackets including cutting for and pinning in ends of brackets or erecting stand including 32mm Waste coupling of PTMT(half or full threaded), complete all as specified. 41 S&F snow white one pice EWC Model Name: CASINO 660X350X760 S trap 220mm with soft colse seat cover, including fixing with screw/boltscomplete all as spcified. 42 S&F Viterious china Urinal,Half stall type, white(excluding flushing cistern,flush pipe) complete incl providing for fixing plugs,bedding urinals against wall in cement mortar 1:2,securing urinal to pulge with and including 60mm long brass screw,pointing around urinal back in cement, including urinal spreader etC, complete all as specified. 43 S & F PVC (SWR) junction single,(Single T) equal or unequal of radius 110mm bore, complete all as specified. 44 S & F 110 mm bore PVC ( SWR) pipes single socketed ,in any length with rubber ring joints, laid in trenches and floor, complete all as specified. 45 S & F PVC (SWR)P traps 110 mm bore, complete all as specified. 46 S & F PVC (SWR) S traps 110 mm bore, complete all as specified. 47 S & F PVC (SWR) bends of radius 110mm bore, complete all as specified. 48 S & F PVC (SWR) vent clow of radius 110mm bore, complete all as specified. 49 Material and Labour for cutting chases for concealed water tubing and making good, (cutting not exceeding 10 cm girth) in cement mortar (1:3), complete all as specified. 50 Supply and fixing steel water tubing of 15 mm bore, medium grade galvanized with provision of all new fittings as required, laids in floor , wall and on ceiling, complete all as specifiedand directed . 51 Supply and fixing steel water tubing of 20 mm bore, medium grade galvanized with provision of all new fittings as required, laids in floor , wall and on ceiling, complete all as specifiedand directed . 52 S&F bib tapcast copper alloy, with cruntch and butterfly handle screwed down , chromium plated, ISI marked,screwed down suitable for 15mm bore pipe or union, complete all as specified. 53 Supply and fixedstop valves, cast copper alloy ISI marked screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for unions, suitable for 20 mm bore tubes, complete all as specified. 54 Supply and fixedstop valves, cast copper alloy ISI marked screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for unions, suitable for 15 mm bore tubes, complete all as specified. 55 Supply andfixingangle valve, 15mm dia chromium plated, cast copper alloy, screwed down, high pressure with capstain head, heavy with adjustable wall flange, complete all as specified. 56 Supply and fixing PVC connection 15mm size with brass nuts of length 450mm complete all as specified. 57 Supply and fixing for CP grating 100 mm dia with or with out hole complete all as specified. 58 S&F for centre hole basin / Wall mixture valve, cast copper alloy fancy type 15mm brass chromium plated mixer (central hole basin mixer w/o pop up waste system) for mixing hot & cold water screwed down for iron pipe, complete all as specified. 59 S&F 8mm thick looking mirrio of size 1.00Mtr X 0.90 Mtr of selected quality glass mounted on 8mm thick AC building border or commercial plywood and aliminium angle bading around mirrior fixed on wall PVC plug and screws etc complete all as spcified abd directed. 60 Supply and fixing for aluminium powder coated ventilator having fixed glass with aluminium section having section 50.80 mm x 25.40 mm (weight 1.137 kg/m) glazing clear section (weight 0.109 kg/m) with plain anodized including supply and fixing of 5mm thick frosted glassmaking frame and glass water tightening making it good and Aluminium grill 6 mm dia design No DG-102 make DEDO grill or design No A-103 make aluminium grill fixed to 50 x 20 x 1.5mm thick etc. Complete all as specified and directed by Engineer-In-Charge. 61 Supply and fixed shower rose 125mm size , brass Chromium plated, revolving type, fixed to existing steel pipe or union 15mm bore complete all as specified. 62 S&F aluminium anodised towel rail 20mm dia D type, 60CM long including fitting complete all as specified. 63 M&L for rendering 10mm thick in CM (1:3) onfaces ofconcrete surface of slab with WPC complete all as specified. 64 M&L APP based polymeric membrane 5 layered of weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) over a coat of hot blown bitumen 85/25 penitration [email protected] Kg/Sqmprimed on bitumen primer @0.4Kg/Sqmcomplete followed by another coat of semi hot blown bitumen 85/25 [email protected] kg/Sqm over the membrane anda coat of aluminium pain tover it, all as specified. 65 S & F toilet paper holder vitrious china box type chromimum plated (CP) brass screws fixed to wall all as spcified and directed. 66 Surface excavation in soft/loose soil n exc 30 cm deep and averaging 15 cm deep and getting out hard and dense soil complete all as specified . 67 M&L for 100 mm PCC(1:5:10) type C2 using 40 mm graded aggregate used as in Sub base Floor/ Pavings and finishing cement concrete surface with out using extra cement, complete all as specified . 68 M & L Chequered cement concrete tiles pre polished lacuqer and glossy finish 30cmx30cmx22-25mm thick over 20mm thick screed bed in CM (1:4) set ,jointedand pointed in neat cement slurry with grey cement and pigment in floors.complete all as specifiedand directed. 69 Material and labour for plain cement concrete type C2 (1:3:6) (Nominal Mix) using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed . 70 M&L for brick work with sub class `B bricks, straight or curved on plan exc 6m mean radius, built in CM 1:3 using old size bricks complete all as specified and directed . 71 M&L for concrete bed (1:4:8) Type D2 to 150 mm drain pipe including packing under and haunching against side of pipes after they are laid and tested all as specified. 72 S & F 150 mm bore PVC ( SWR) pipes single socketed ,in any length with rubber ring joints, laid in trenches and floor etc. 73 M&L for Cement concrete (1:2:4) Type B1 in lintels upto1.5m clearspan,cills,steps; seismicand other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , watertroughs and the like includingweathering,slightly roundedor chamfered angles andthroating, complete all as specified and directed . 74 Materials and labour for rendering 15 mm thick in cement mortar (1:4) on wall finished even and smooth without using extra cement with water proof compound as per manufacturer instruction complete all as specified and as directed. 75 Material & labour for RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in precast cement concrete for cover slab set in cement mortar (1:4) with necessary form work complete all as specified and as directed . 76 M & L of On site CONVENTIONAL type LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, 150 mm thick PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for capacity of 3000 ltr,complete all as specified and directed. 77 M&L PCC 1:3:6 type C-2 (20 mm graded aggregate) in in surface channel and drain etc including necessary form work etc, complete all as spcified and diracted. 78 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete , using extra cement , including forms , moulds , mitred / stopped ends etc 79 S&F 25 mm bore dia steel water tubing medium grade galvanised with all fitting (i.e. Tee, socket, bend etd) complete to walls and ceilings or laid in floors, complete all as specified and directed by Engr-in-Charge. 80 Supply and fixed Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25 mm dia, complete all as specified and directed by Engr-in-Charge. 81 Supply and fixed Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm dia, complete all as specified and directed by Engr-in-Charge. 82 M&L Cutting existing steel tubing 50 mm dia for alterations or additions (Each cut measured) 83 Screwing existing steeltubing 40-50 mm dia for alterations or additions (or lengthening screw on pipe to form connector). 84 M&L for point wiring for one 15 Amps socket point controlled by one switch concealed type with PVC insulated unsheathed copper cable FRLSH 2.5 sqmm multi stranded two single copper conductor in and including suitable size PVC conduit pipe 20 mm dia complete with all accessories and with 1.5 sqmm PVC insulated copper cable FRLSH continous earth wire, re-recessed mounting pressed steel GI sheet box 2 mm thick suitable for modular switch/socket of adequate size including inner and outer PVC white cover plate of modular complete all as specified and directed. 85 Supply and fixing of modular switch single pole one way 16 Amps 1 module complete all as specified and directed 86 Supply and fixing of modularsocket 6 A/16 amp -3/5 pin combined 2 module complete all as specified and directed. 87 Supply and fix Water heater storage type, electric, capacity 25 litres230V,50Hz BEE 4 star or above. Made of steel body with steel inner tank covered with glass wool with all connected items and fittings like NRV, Safety valve,PVC connection pipe etc, , complete all as specified & directed. 88 Cutting, Screwing, threading of existing cast iron / GI pipe of 20mm in position for insertion oftee/nipple/gate valve of 15mm bore including fittings viz tee, collar, bend or tail piece etc, complete all as specified & directed. 89 Supply, laying, jointing and testingXLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area16 Sqmm 2 core, complete all as specified and directed by Engineer-in-Charge. 90 Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge. 91 M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed. 92 Deduction to be made from BOQ for schedule of credit (Sch A Part - II) Amount of ₹ Nilduring AOCNote:- Tenderers shall not quote for this Schedule
Contract Date: Aug 30, 2025 Contract Value : 8.56 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Jammu And Kashmir View Result →
44.
Defence #7869913 AOC
Tender For Provision Of Deficient Married Accommodation At Fazilka Mil Stn (Job No: - Mwp/Swc-02/2024-25); 1 Lump sum price worked out by the tenderer for“BUILDING /STRUCTURE WORKS as listed in Schedule ‘A’ Section - I 2 Sch A Section- II, INTERNAL ELECTRIFICATION WORKS AND FLAME PROOF FITTINGS 3 Material and labour for concealed Point wiring for one light point/fan point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3)including fixing ofswitch/socket/regulator etc complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). 4 -do- all as per srl No. 3 above but one three pin switch socket outlet 5 Amps on the same borad 5 -do- all as per srl No. 3 above but one call bell controlled by one bell switch 6 -do- all as per srl No. 3 above but wiring with 2.5 sqmm multistranded cable and earth wire with copper conductor of size 2,5 sqmm for 5 Amps point (on independent board) 7 Material and labour for concealed Point wiring for one socket outlet 15/20 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area)single core FRLSH PVC insulatedunsheathed and multi strand copper conductor cable 1100 volt (ISI marked)drawn through andincludingPVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM(1:3), including fixing ofswitch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of moudlar cover plate with frame and labour for fixing the same shall deemed to be included in the unit rate). 8 Supply only modular switch 6Amps, piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring). 9 Supply only modular switch 16Amps,piano flush type, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring). 10 Supply only modularsocket outlet 2 in 1, 6Amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring). 11 Supply only modularsocket outlet 5 in 1, 16Amps,flush type fixed on laminated sheet top cover complete all as specified and as directed by Engineer-in-charge (laminated sheet top cover is included in point wiring). 12 Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 2 to 3 terminal, 240 volts, 5/6 Amp, ISI Marked complete all as specified and as directed by Engineer-in-charge. 13 Supply and fixingelectric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection complete all as specified and as directed by Engr-in-charge. 14 Supply only modular Bell Push switch, piano flush type, 6Amps, single pole, one way (1 module) fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by Engineer-in-charge. 15 Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of B class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable sizefrom ceiling rose to fan complete all as specified and as directed by Engr-in-charge.Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account 16 Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge.Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. 17 Supply and fixed for SPN 8 way, 240 volt distribution board door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with Bus bar rating 200 Amps, dust and vermin proof, IP-43 protected, suitable for incorporation of MCBs and isolators etc complete all as specified and as directed by Engineer-in-charge. 18 Supply and fixed for SPN 6 way, 240 volt distribution board door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with Bus bar rating 200 Amps, dust and vermin proof, IP-43 protected, suitable for incorporation of MCBs and isolators etc complete all as specified and as directed by Engineer-in-charge. 19 Supply and fixed for SPN 4 way, 240 volt distribution board door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with Bus bar rating 200 Amps, dust and vermin proof, IP-43 protected, suitable for incorporation of MCBs and isolators etc complete all as specified and as directed by Engineer-in-charge. 20 Supply and fixed for TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper Bus bar suitable rating with neutral bar and earth bar and cable tie for cable management, IP-54 protection and provision and including MCCB 4 pole 160 Amp, 16 KA as incomer and MCBs as outgoing, dust and vermin proof complete all as specified and as directed by Engineer-in-charge. 21 Supply and fixed of MCB suitable for 240 volts AC Supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, C Curve as 6 to 32 Amps complete all as specified and as directed by Engineer-in-charge. 22 Supply and fixed of MCB suitable for 240 volts AC Supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, B Curve as 40 Amps complete all as specified and as directed by Engineer-in-charge. 23 Supply and fixed of MCB suitable for 240 volts AC Supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, B Curve as 6 to 32 Amps complete all as specified and as directed by Engineer-in-charge. 24 Supply and fixing blanking plate of plastic suitable for any type of DB complete all as specified and as directed by Engineer-in-charge. 25 Material and labour for submain wiring comprising single core, 2 Runs of 4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 20mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x4.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted. 26 Material and labour for submain wiring comprising single core, 2 Runs of 6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 25mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted. 27 Material and labour for submain wiring comprising single core, 2 Runs of 10.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade drawing in and including PVC conduit of size min 25mm dia ISI marked and its fittings concealed in floor/roof / wall complete including provision of 01x6.0 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 volts grade as earth wire and using color code as per IS complete all as specified and as directed by Engineer-in-Charge. Note : Meter of pipe including fitting and 3 runs of single core cable shall be measured as unit Runing meter. Additional wire/cable required for connecting to MCB shall be included in overall cost quoted. 28 Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. 29 Supply and fixing LED tube light fitting polycarbonate housing 1 x 18/20Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 10°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g) Aluminium housing & Integrated Electronic driver(h)LED Driver of the same make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6500K(m) CRI : more than 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 30 Supply and fixing LED tube light fitting polycarbonate housing 1 x 10Watt, appx 2 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 01 sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 10°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g)LED Driver of the same make as of the luminaire.(h) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6500K(l) CRI : more than 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 31 Supply and fixing LED lamp 1x9 watt including PVC holder with complete suitable for fixation on wall/roof with body robust corrosion resistant, superior flnish and without any cracks of through holes complete all as specified and directed by Engineer-in-Charge 32 Supply and fixing energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing medium grade 32mm dia, 1.2 metre long bent to shape at 32 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: More than 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 33 Rigid non metallic PVC Conduit 20mm dia (external) for sub main/telephone wiring inclusive of all fittings such as tees, bends, elbow, reducers, junction boxes bell mouth tube ends and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and as directed by Engineer-in-charge. 34 Material and labour for Mild steel boxflush mounted of size 100mm x100mmx100mm having holes for 20 mm conduit entry including 02 pin TV socket outlet flush type marked with symbol of TV and 03 mm thick plastic laminated sheeet cover and making good disturbed surfaces of walls by using CM (1:3)complete all as specified and as directed by Engineer-in-Charge 35 Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS body of capacity 25 litres, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection 600mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. 36 Supply and fixing for LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 37 Supply and fixing Earth continuity conductor or main earthing lead 32x6mm galvanised iron strip including nuts bolts and washer fixed to wall with saddles and fixing screws or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including making good disturbed surface complete all as specified and as directed.Note :- (i) Conduit/pipe as required, same shall be measured & paid separately under respective item of this Sch/BOQ. 38 Subtotal 39 Lump sum price worked out by the tenderer for“INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Section - III (Part-I) 40 Sch A Sec - III (Part-II), INTERNAL WATER SUPPLY WORKS 41 Supply and fixing two way Bib cock/Angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed ends suitable for 15 mm bore pipe iron pipe or for brass ferrule/unions and fixed complete all as specified and as directed. 42 Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 16 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ. 43 Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 20 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ. 44 Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 25 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ.Note for CPVC pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by Engr-in-charge. 45 Supply and fixing chlorinated polyvinyl chloride (CPVC) pipe heavy duty outer dia 40 mm having thermal stability for hot and cold water supply including all new CPVC fittings plain & brass threaded like elbow, tee, union, socket, reducer etc. including CPVC solvent cement for jointing and fixed complete to walls, ceiling or laid in floor including complete all as specified and as directed by Engineer-in- charge. Note :- Cutting chases if required same shall be measured and paid separately under appropriate item of BOQ.Note for CPVC pipes : pipes inside the building shall be fixed concealed and outside the buildings shall be fixed on the surface with wall hooks as directed by Engr-in-charge. 46 Supply and fixing single lever concealed diverter incl bath spout & Shower complete all as specified and as directed by Engineer-in-charge. 47 Supply and fixing for brass chromium plated Aquaguard/RO inlet valve or diverted valve with nozzle compatible for all type of water purifier fixing to steel pipe of socket of 15mm bore complete all as specified and as directed by Engineer-in-charge. 48 Supply and fixing for 40mm bore CPVC long handle vavle complete all as specified and as directed by Engineer-in-charge. 49 Supply and fixing health faucet fancy type, CP including 1.25 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by Engineer-in-charge. 50 Subtotal 51 Lump sum price worked out by the tenderer for“ROAD, PCC TILES ANDHUME PIPE CULVERT WORKS) as listed in Schedule ‘A’ Section -IV (Part-I) 52 Sch A Sec - IV (Part-II), ROAD, PCC TILES ANDHUME PIPE CULVERT WORKS 53 Material and labour for premix bituminous concrete 40mm consolidated thicknesswith min 5.4 % binder content (bitumen of grade VG-30)by weight of total mix using sensor paver electronic sensing device for automatic leveling and profile control withi the specified toleranceand internal heating arrangement for the screed all as specified in Table 500-17 of MoRTH specification for road and bridge works 2013, rolled and compacted to required camber and gradient with tandem vibratory roller 8 to 12 tonne power roller to a uniform smooth surface complete all as specified and as directed by Engineer-in-Charge. 54 Material and labour for Thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by Engineer-in-Charge 55 Supply and laying/fixing 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by Engineer-in-ChargeNote:- Tiles shall be approved by GE before incorporation in the work. 56 Material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used. 57 Material and labour for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. 58 Subtotal 59 Lump sum price worked out by the tenderer for“(AREA DRAINAGEWORKS) as listed in Schedule ‘A’ Section -V 60 Lump sum price worked out by the tenderer for“SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Section - VI (Part-I) 61 Sch A Sec - VI (Part-II), SEWAGE DISPOSAL WORKS 62 Supply and laying DWCPE (SN8) drain pipes 180 (OD)/163(ID) mm dia pipe as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge.Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch 63 Supply and laying DWCPE (SN8) drain pipes 200 (OD)/175(ID) mm dia pipe as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge.Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch. 64 Subtotal 65 Lump sum price worked out by the tenderer for“SECURITY FENCING AND GATE WORKS as listed in Schedule ‘A’ Section - VII 66 Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Section-VIII (Part-I) 67 Sch A Sec - VIII (Part-II),EXTERNAL WATER SUPPLY WORKS 68 Supplying, laying, jointing and testing Ductileiron pipe (ISI marked) class K-7, bore 150mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge.Note : (i)Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate. 69 Supply and fixing cast iron sluice valve 150 mm dia with flanged ends class PN 1.6(heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge. 70 Material and labour for Construction of brick masonary valve pit chamber size 90 X90 X90 cm (internal dimension) using sub class B bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed by Engineer-in-Charge. 71 Subtotal 72 Lump sum price worked out by the tenderer for“EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION WORKS as listed in Schedule ‘A’ Section - IX (Part-I) 73 Sch A Sec - IX (Part-II), EXTERNAL ELECTRIFICATION AND LIGHTNING PROTECTION WORKS 74 Supply and fixing lightning arresters HT 11000 V non linear expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, confirming to IS 3070 (Part-I) 1985 complete all as specified and as directed by Engineer-in-Charge. 75 Supply, installing, commissioning & testing energy efficient transformer suitable for 315 KVA (Level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 Hz AC, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with for earthing and having tapping on HV side for constant output so as to alter/vary secondary voltage (Tapping range + 5 %to - 10% in equal step of 2.5 % ) changed by means of manually operated off load taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories. The limit of temperature rise after continuous full load run as specified in IS-1180 (Part-I) 2014 and BEE Certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :- 76 (a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) Silica gel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) Air release valve plug (e) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) Explosive vent (g) 01 No 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) Thermometer pocket on tank cover (j) 04 Nos plain solid CI detachable rollers (k) Two Nos Earthing terminals marking plate. (l) Rating plate and terminal marking plate(m) Extra bushing for neutral outside the cable box brought out on LV side. (n) First filling of oil conforming to IS and tested upto 60 KV dielectric strength (o) Lifting lugs (p) Oil drain valve with plug (q) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints complete all as specified (r) Hand hole of sufficient size to assess interior of tank (s) Dehydrating breather with first filling of Dehydrating agent (t) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strip. (u) Rating plate with terminal marking plate (v) Inspection cover. 77 Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 Nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by Engr-in-charge and comprising of following accessories:- 78 (a) Copper bus bar of 800 Amp capacity, 4 strip mounted on porcelain insulators. (b) MCCB 4 pole with thermal magnetic release adjustable type with breaking capacity 36 KA, 500 Amp (Incomming).(c) MCCB 4 pole with thermal magnetic release adjustable type with breaking capacity 25 KA, 125 Amp - 07 (for 07 blocks).(d)MCB TPN 32 Amps -01 Nos (for street lights).(e) Digital Voltmeter 96x96mm flush secure panel mounting type 0-500V with selector switch -01.(f) Digital Amp meter 96x96mm flush secure panel mounting type 0-400Amp with selector switch with CT -01. (g) RYB LED indicating lamp set of three -01. 79 Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 Nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by Engr-in-charge and comprising of following accessories:- 80 (a)Aluminium bus bar Cap 150 Amp capacity with heat shrinkable PVC Colour sleeves - 04 Nos.(b) MCCB 4 pole with thermal magnetic release adjustable type with breaking capacity 36 KA, 100 Amp (Incomming).(c) MCB SPN with thermal magnetic release adjustable type with breaking capacity 16 KA, 32 Amp - 16 (outgoing).(d) Digital Voltmeter 96x96mm flush secure panel mounting type 0-500V with selector switch -01.(e) Digital Amp meter 96x96mm flush secure panel mounting type 0-400Amp with selector switch with CT -01. (f) RYB LED indicating lamp set of three -01. 81 Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of suitable size, outdoor type (double door both side openable including locking arrangements) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick powder coated and fully compartmentalized inner panel with 2 mm thick CRCA sheet powder coated, to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including provision of rubber beading and brass cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, complete with separate bus bar chamber, panel shall be mounted on angle iron frame and 04 Nos legs made from angle of size 50x50x6mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted with seven tank process internally and externally with two coats of synthetic enamel over a coat of red oxide primer, internal wiring of panel board with solid conductor copper cable single core of suitable size, danger notice plate for LT with conventional skull and bones duly rivited/ pasted to the panel board door, complete including all connection incoming/ outgoing all as directed by Engr-in-charge and comprising of following accessories:- 82 (a)Aluminium bus bar Cap 150 Amp capacity with heat shrinkable PVC Colour sleeves - 04 Nos.(b) MCCB 4 pole with thermal magnetic release adjustable type with breaking capacity 16 KA, 100 Amp (Incomming).(c) MCB SPN with thermal magnetic release adjustable type with breaking capacity 16 KA, 20 Amp - 07 (outgoing).(d) Digital Voltmeter 96x96mm flush secure panel mounting type 0-500V with selector switch -01.(e) Digital Amp meter 96x96mm flush secure panel mounting type 0-100Amp with selector switch with CT -01. (f) RYB LED indicating lamp set of three -01. 83 Supply and fixing cable junction box of Size 280mm x 200mm x100mm or any other higher size (Suitable for Pole mounting) complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :-(a) The junction box shall be rated for degree ofIP 65 (ingress protection) in accordance with IEC 60529.(b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded.(c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60695-22, IEC 60670-2 to 5 and grey color according to RAL-9011/ 7035.(d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree.(e)Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08.(g) Junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20Amp MCB SP 10KA (h) Manufacturer should submit routine test certificate for junction box. (j) Suitable size of mild steel Clamps and screws/nut bolt shall be used for fixing of Junction box.. 84 Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GIearthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto 7.5 mtr length, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common saltall around bottom and top. 20 mmbore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type ofsoil, returning filling and disposal of surplus soil to a distance not exceeding 50m,Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat ofred oxide primer, complete all as specified & shown in electrical plate No. 3 ofSSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto 7.5 mtr from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. 85 Material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used. 86 S&F for GI steel light grade 32 mm dia bent to shape of offset angle upto 45 degree for fixing of security light fitting GI Pipe 1.5 Mtrs including MS Clamp and nut bolts complete all as specified and as directed by Engr-in-Charge. 87 Subtotal 88 Sch A Sec - X, FIRE FIGHTING EQPT WORKS 89 Supply and fixing fire hydrant landing valve type A (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to IS 903 (for internal hydrant at Ground floor to 3rd floor and roof) complete all as specified and as directed. 90 Supply, installing, commissioning and testing of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MSSteel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, Finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( Sample to be approved prior to entire supply) complete all as specified and as directed. 91 Supply, installing, commissioning and testingof wall mounting swinging type First aid firehose reel with drum, hanging bracket, 30 mtr long and20mm dia high pressure hose reel as per IS 444 with gunmetal shut off nozzle having 5mm dia orifice. The hose reel shall be conforming to IS 884-1985. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or MS stand as per site requirement complete all as specified and as directed. 92 Supply, installing, commissioning and testing of 63mm dia Gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with GM nozzle of 20 mm nominal size conforming to IS 8090 complete all as specified and as directed. 93 Supply, installing, commissioning and testing of gun metal body Butterfly valves of size 63mm dia, IS:210, PN-16, confirming to IS:13095 complete all as specified and as directed. 94 Supply, installing, commissioning and testing of Booster Pump 30 m head, 450LPM discharge, 440 V, 3 Phase, 50Hz confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed. 95 Supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, MS heavy duty (C Class) flanged pipe, ISI marked (IS : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed. 96 Supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 Ltr capacity conforming to IS:13386 with extinguishing agent :water+AFFF and propelling Nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 Mtrs.,with ISI certification markcomplete all as specified and as directed. 97 Supply and fixing carbon-di-oxide 3 Kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing No., confirming to IS:15683:2006. Fire rating 3A: 89B, ISI certification mark complete all as specified and as directed. 98 Supply and fixing Dry Chemical Powder Fire Extinguisher ( ABC POWDER ) 9 Kgs capacity Stored Pressure type, CE Mark Valve with NRV & Safety Release Provision with EPDM Rubber Hose, The extinguisher is internally coated with Epoxy Polyester and externally coated with Pure Polyester Powder and confirming to IS:15683:2006. Fire rating 3A: 89B, ISI certification mark complete all as specified and as directed. 99 Supply and fixing mechanical foam Extinguisher of 9 Ltr capacity and confirming to IS:15683:2006 complete all as specified and as directed. 100 Supply and fixing fire buckets (dry sand)of 7 Kg capacity including hanging arrangements complete all as specified and as directed. 101 Supply and fixing emergency Exit Sign Board with double side adhesive tape vinyl sticker with forex board (Green and White colour) 30 cm x 10 cm complete all as specified and directed. 102 Subtotal 103 Lump sum price worked out by the tenderer for“LIFT WORKS as listed in Schedule ‘A’ Section - XI (Part-I) 104 Sch A Sec - XI (Part-II), (LIFT WORKS) 105 Supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G + 3 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ARD) system, 2D infrared sensor in full height of door & built in press and speak 3 way intercom. Complete all as specified and as directed and shall conform to the following specifications: 106 Type of Lift : Passenger Lift 107 Capacity of Lift : 884 Kg, 13 Person 108 Rise : up to G+3 Bldg 109 Stop and opening - 04 stops with all opening on the same side 110 Controller type : Microprocessor based 111 Drive : AC VVVF drive 112 Power Supply : 400/415 Volts (3 Phase AC) 113 Operation : Full collective operation 114 Car Group : Simplex Type 115 Machine : Gearless motor located above shaft in machine room 116 Traction Media : Steel rope 117 Car Finish : Rear Mid Panel, Rear Corner Panel, Side Mid Panels, Side Corner Panels, Front Panels all are made of Stainless Steel SS304 with honey comb finish 118 False Ceiling Finish : Stainless steel with hairline finish and with provision for LED lights specified here-in-after. 119 Ventilation : PVC heavy duty Cross Flow Fans 120 Hand Rails : Stainless Steel Finish round Handrails on rear car panels 121 Flooring :20mm thick Granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick. 122 Car door and Landing Door finish : Stainless steel SS-304, mirror finish outside 123 Fire rated doors : Fire rating - 60 Minutes 124 PIT DEPTH: 1600 125 OVERHEAD : 4500 126 HOISTWAY DIMENSIONS(W x D – mm) : 2500 mm W x 1900 mm D 127 Car Size (W x D x H - mm) : As per IS-14665 (Part 3 Sec-I) : 2000, height 2200 mm 128 CAR & HOISTWAY DOOR TYPE : Central opening (CO) doors 129 DOOR OPENING (W x H - mm) : 900 mm W x 2000 mm H 130 DOOR OPERATOR : VF 131 COP : COP (car operating panel) and LOP (landing operating panel) in Stainless Steel Hairline finish with display. 132 CAR POSITION INDICATOR : Dot Matrix type 133 HALL FIXTURES : Dot Matrix type 134 HALL FIXTURE FACE PLATE : Stainless steel hairline finish-SS-304 135 HALL BUTTON ARRANGEMENT: Hall and call Buttons with illumination and Braille 136 Car and counter weight guide as per OEM recommendation 137 Terminal buffers metal spring/oil buffer as per OEM recommendation 138 STANDARD FEATURES :Anti-nuisance Car Call Protection, Independent Service, Overload Device, Nudging, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking Door Open/Close Button, Manual Rescue Operation, Auto Fan Cut Off, Over Speed Governor for Car 139 ALSO INCLUDED : Emergency Firemen’s Service, Automatic Rescue operation, Intercom. 140 Car Enclosure: Manufactured with stainless steel frame not less than 1.5mm with honey combfinish (SS-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED sleek light fittings (as per manufacturer’s instructions, minimum 04 Nos) operated on commercial supply and one LED light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection 141 Floor announcement system in car cabin 142 Signals: (a) Combined luminous hall buttons with LED hall position indicators at all floors (b) LED car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing (e) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One firemans switch to be installed at ground floor near landing door. (h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) Infrared door sensor safety edge of door for entire height. 143 Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open. 144 Operation: Simplex, full collective automatic operation 145 Machine Room: Located above the hoist way, details as per building drawings 146 Hoist way: Construction details as per building drawings 147 Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. 148 One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room 149 Looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail 150 Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor 151 Subtotal 152 Lump sum price worked out by the tenderer for“EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS as listed in Schedule ‘A’ Section - XII 153 Schedule A Section -XIII (Furniture Works) 154 Almirah small steel as per drawing No. FD-1032 sheet No. 1/1 155 Book shelf open (large) steel as per drawing No. FD-69(M) sheet No. 1/1 156 Bed Hard as per drawing No. FD/E6/MAP/08(R) sheet No. 1/1 157 Chair Verandah as per drawing No. FD/E6/MAP/11 sheet No. 1/1 158 Charpoy folding IP with hard top as per drawing No. FD-388(R) sheet No 1/1 159 Peg Table as per drawing No. FD/MAP/11 sheet No. 1/1 160 Rack shoe steel as per drawing No. FD/E6/MAP/02(R) sheet No. 1/1 161 Table bed Side as per drawing No. FD/E6/MAP/15(R) sheet No. 1/1 162 Table Centre as per drawing No. FD/MAP/08 sheet No. 1/1 163 Dressing Table including Stool as per drawing No. FD/MAP-II/07 sheet Nos 1/2 & 2/2 164 Chair dining JCOs/Ors as per drawing No. FD/MAP-II/05 sheet No. 1/1 165 Chair easy per drawing No. FD-229 sheet No. 1/1 166 Chair writing as per drawing No. FD-280 sheet No. 1/1 167 Charpoy with hard top as per drawing No. FD/MAP-II/01 sheet No. 1/1 168 Mirror dressing(Gents) as per drawing No. FD/E6/MAP/16 sheet No. 1/1 169 Table dining 4 persons as per drawing No. FD/MAP-II/03 sheet No. 1/1 170 Table with drawer (900 mm X 600 mm X 760 mm) as per drawing No. FD-283 sheet No. 1/1 171 Chair School with hand board as per drawing No. FD/E6/MAP/05 sheet No. 1/1 172 Note:-Quantities of materials given on standard drawings are for guidance only. The contractor shall work out the quantities of materials required for each item of BOQ and quote his rate accordingly no claim shall be entertained on account of inaccuracy in the quantities of these materials and workman ship which shall be as specified in particular specifications and as approved. The drawing Nos mentioned in BOQ item No 184 to 264 shall form part of tender document which will not be attached with tender document. The tenderers are deemed to be in possession and conversant fully with the drawing shown in standard furniture designs including amendments published by AHQ, Engineer-in -Chief, New Delhi. For reference and guidance the tenderer may study and see these drawings in the any office ofGarrison Engineer in MES before quoting their rates. No claim shall be entertained regarding misinterpretation of the drawings at a later stage. 173 Subtotal 174 Lump sum price worked out by the tenderer for“ARBORICULTURE WORKS as listed in Schedule ‘A’ Section - XIV (Part-I) 175 Schedule A Section -XIV (Part-II) (ARBORICULTURE WORKS) 176 Material and labour for Grassing with Selection No.1 grass including enough watering and maintance of the lawn till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed including supplying and spreading of Neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass complete all as specified and as directed. 177 Supply and planting of Hedge and Shrubbery (Anarmi, Ficus and the like) as directed by Engineer-in-Charge minimum 3 feet above GL including creation of beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with Sludge or manure in the ratio 8:1 (8 Part of stacked volume of earth after reduction of 20 % with 1 part of stacked volume of sludge or manure ater reduction by 8%) flooding with water filling with earth if necessary, watering and finally fine dressing leveling etc including stacking and disposal of material declared unserviceable and surplus earth by spreading and leveling as directed within a lead 50 m and lift upto 1.50 m complete all as specified and as directed. 178 Supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & lick compacted bed farce dory meinod using fu mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand;complete all as specified and as directed by Engineer-in-ChargeNote:- Tiles shall be approved by GE before incorporation in the work. 179 Material and labour for sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and as directed.Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used. 180 Supply and laying factory made kerb stone of size 30x15x45cm of M-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed by Engineer-in-Charge 181 Supplying following plants in poly bags 0.25 m to 0.30m dia with height 1.20 m to 1.80 m including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 2:1(2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludgeor manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals or pesticides of approved quality, as required and making Thaola all as specified and as directed by Engineer-in-charge.Note :- Contractor shall maintain the trees till physical completion of contract.Unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 182 Neem Tree. 183 Canerydate Palm 184 Gulmohar 185 Fruit Bearing Trees 186 Plumeria 187 Supplying plants Flower like Ticoma, rose,motia, Chandni, lxora, marigold rose, vinca (any colour) as directed of height not less than 0.60m above GL including digging holes 1.20m dia x1.2m deep in ordinary soil and refilling the same with the excavated earth mixed with manure of approved quality or sludge in ratio 3:1(One part of manure & 3 part of soil) manure 200 gm per plant ,flooding with water and removal of surplus soil n.exc 1.50 Km and depositing where directed with & including using suitable chemicals or pesticides of approved quality, as required and making Thaola all as specified and as directed by Engineer-in-charge.Note :- Contractor shall maintain the trees till physical completion of contract.Unit rate quoted is inclusive of replacement of dead trees,manures and all fertilizers mentioned above is inclusive in rate quoted. 188 Supply and Fixing precast RCC 1:1.5:3 Type A1 lawn bench and backsupport of size 1.50 x 0.60m of maximum three person seating capacity supporting precast RCC type A1 for back and base with including assemble the precast member with suitable nutt & bolt and placing and anchoring with hold fast 350mm - 16mm dia MS bar on concrete base (size 1.20x0.60m for each support) with 100mm thick PCC 1:2:4 Type B1 over 150mm thick sub base PCC 1:4:8 type D2 complete all as specified and as directed by Engineer-in charge 189 Subtotal 190 Schedule A Section -XV ( Maintance) 191 Material and labour for the plants/hedge/grass by weeding, hosing, saucer making once in every month for plants/hedge, once in every 15 days for carpet grass/country grass/doob grass, bermuda grass, pruning dired ranches once in every week, depositing the material at place of dead plants of same species and height turning with dods whenever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department all as specified and as directed. (plants of various species -678 Nos (approx), Hedge and shruery - 520 RM (approx) and Grass - 4000 sqm( approx) 192 Subtotal
Contract Date: Aug 27, 2025 Contract Value : 31.40 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
45.
Educational and Research Institute #7737590 AOC
Notice Inviting Tender For Established Publishers, Dealers ,Firms For The Supply Of Library Books , Gps Satellite Surveying , Electronic Distance Measurement: An Introduction , Introduction To Geographic Information Systems , Irrigation Engineering And Hydrualic Structures , Fluid Mechanics And Hydraulic Machine , Hydraulics And Fluid Mechanics , Solid Waste Engineering , Industrial Water Pollution Control , Environmental Pollution Control Engineering , Water Supply Engineering , Sewage Disposal And Air Pollution Engineering , Water Supply Engineering Vol-1 , Wastewater Engineering Vol-2 , Testing Ofmaterials , Structural Design And Drawing , Soil Mechanics And Foundation , Soil Mechanics And Foundation Engineering , Engineering Mechanics Statics And Dynamics , Maintenance,Repair And Rehabilitationand Minor Works Of Buildings , Rehabilitation Of Concrete Structures , Soil Mechanics And Foundation , Strengthmaterials , Staad Pro V8i For Beginners With Indian Examples , Design Of Industrial Building Using Staad Pro , Building Construction , Construction Technology And Management , Irrigation Engineering , Illustrated Design Of Reinforced Concrete Buildings , Highway Engineering , Urban Development And Management , Climate Change – An Indian Perspective , Elementary Structural Dynamics , Advanced Structural Dynamics , Earthquake Resistant Design Of Structures , Introduction To Earthquake Analysis Of Structures , Fudamentals Of Steel Design , Engineering Mechanics , Structural Analysis 1 & 2 , Strength Of Materials , Matrix Analysis , Ground Water Hydrology , Surveying Vol I , Surveying Vol Ii , Sustainable Construction Processes: A Resource Text , Industrial Safety, Health, Environment Management System , Industrial Safety Management Hazard Identification And Control , Think Python: How To Think Like A Computer Scientist , Programming In C , Digital Design: With An Introduction To The Verilog Hdl, Vhdl, And System Verilog , Python Data Science Handbook , Introduction To Data Structures In C , Introducing Javafx 8 Programming , Introduction To Machine Learning , Database System Concepts , Perspectives In Environmental Studies , Computer Networking, A Top-Down Approach Featuring The Internet , Compilers: Principles, Techniques And Tools , Cryptography And Network Security - Principles And Practice , Cyber Security: Understanding Cyber Crimes, Computer Forensics And Legal Perspectives , Advanced Concepts In Operating Systems , Object-Oriented Software Engineering: Using Uml, Patterns And Java , Object-Oriented Software Engineering: An Agile Unified Methodology , Hands-On Exploratory Data Analysis With Python , Exploring Data: An Introduction To Data Analysis For Social Scientists , Recommender Systems: An Introduction , Business Analytics , Head First Android Development , Cloud Service Management And Governance: Smart Service Management In Cloud Era , Ux For Beginners , Web Application Security: Exploitation And Countermeasures For Modern Web Applications , A Practical Guide To Git And Github For Windows Users: From Beginner To Expert In Easy Step-By-Step Exercises , Concepts Of Programming Languages , Distributed And Cloud Computing, From Parallel Processing To The Internet Of Things , Cloud Computing A Practical Approach , Data Warehousing, Data Mining & Olap , Introduction To Storage Area Networks , Foundations Of Modern Networking: Sdn, Nfv, Qoe, Iot And Cloud , Streaming Systems: The What, Where, When And How Of Large-Scale Data Processing , Cloud Computing:? , Hands-On Ethical Hacking And Network Defense, Course Technology , Digital Forensics , Social Networks And The Semantic Web , Introduction To Cryptography: Principles And Applications , Software Security Engineering , Mastering Blockchain: Deeper Insights Into Decentralization, Cryptography, Bitcoin, And Popular Blockchain Frameworks , Cryptography And Network Security: Principles And Practice , Virtual Reality Blueprints: Create Compelling Vr Experiences For Mobile , Fundamentals Of Multimedia , Fundamentals Of Digital Marketing , Learning Robotic Process Automation: Create Software Robots And Automate Business Processes With The Leading Rpa Tool – Uipath , Introduction To Cyber Security Guide To The World Of Cyber Security” , Quantum Computing, A Beginners Introduction , 3D Printing: The Next Industrial Revolution , Knowledge Engineering Building Cognitive Assistants For Evidence-Based Reasoning , Cognitive Computing: Theory And Applications , Rf And Dsp For Sdr , Iot Fundamentals Networking Technologies, Protocols And Use Cases For The Internet Of Things , Linearintegratedcircuits , Micro Electronic Circuits , Fundamentals Of Digital Image Processing , The Nonreligious: Understanding Secular People And Societies , Research Methodology For Natural Sciences , Principles Of Embedded Computing Systemdesign, , Internet – Of- Things – A Hands On Approach , Data Communication And Networking , Cryptography And Network Security , Hardware Security –A Hands On Approach , Wireless Communications , Essentials Of Vlsi Circuits And Systems , Low Voltage, Low Power Vlsi Subsystem , Design Of Analog Cmos Integrated Circuits , Rf Microelectronics , The Design Of Cmos Radio-Frequency Integrated Circuits , An Introduction To 5G Wireless Networks : Technology, Concepts And Use Cases , Introduction To Machine Learning , Internet Of Things: Architecture, Design Principles And Applications , Satellite Communication , Research Methodology For Natural Sciences , Modern Electric, Hybrid Electric And Fuel Cell Vehicles: Fundamentals, Theory And Design , Green Supply Chain Management , Energy Storage: Fundamentals, Materials And Applications , Fundamentals And Applications Of Renewable Energy , Automobile Engineering”, Vol 1 & 2 , Industrial Safety, Health And Environment Management Systems , A Text Book Of Engineering Graphics , Autodesk Fusion 360: A Power Guide For Beginners And Intermediate Users , Four Laws That Drive The Universe , Fundamentals Of Engineering Thermodynamics , Engineering Mechanics Statics & Dynamics , Mechanics Of Materials , A Text Book On Heat Transfer , Engineering Optimization Theory And Practice , Engineering Chemistry , Engineering Chemistry-Fundamentals And Applications , Text Book Of Nanoscience And Nanotechnology , Environmental Science And Engineering , Introduction To Environmental Engineering And Science, 2Nd Edition , Perspectives In Environmental Studies , Engineering Applications In Sustainable Design And Development , Basic Concepts In Environmental Management , Environmental Law , Environmental Studies-From Crisis To Cure , Text Book Of Environmental Studies For Undergraduate Courses , Soft Skills Know Yourself And Know The World , Who Moved My Chees? , Ikigai , Do It Today , Train Your Brain , How To Win Friends & Influence People , Attitude Is Everything , A Story Can Change Your Life , The Alchemist , Success Through A Positive Mental Attitude , Think And Grow Rich , Eat That Frag! Isbn (978152309293) , Ignited Mind (Isbn 0-670-04928-X) , Learning How To Fly Life Lessons For The Youth , Inspiring Thoughts , Unbreakable : An Autiobiography , 100 Greatest Leader , How The Earth Got Its Beauty , Best Stories From Around The World , The Power Of Habit , A Guide To Health And Happiness , The Psychology Of Money , Believe In Yourself , Sidney Sheldon Are You Afraid Of The Dark , The 7 Habits Of Higly Effective People , An Introduction To Mechanics , Electricity And Magnetism , Concepts Of Modern Physics , Building Physics , Elements Of Properties Of Matter , Materials Science And Engineering: A First Course , Principles Of Electronic Materials, And Devices , Semiconductor Devices: Basic Principles , Semiconductor Optoelectronics: Physics And Technology , Fundamentals Of Nanoelectronics , Semiconductor Device Fundamentals , Quantum Computing: A Beginners Introduction , Electrical Properties Of Materials , Quantum Mechanics With Applications To Nanotechnology Andinformation Science , Introduction To Nanoelectronics , Physic Volume 1 & 2, , Non-Conventional Energy Sources , Wind Energy System , Hybrid Energy Systems , Emergingpower Converter For Renewable Energy And Electrical Vehicles , Power Electronics , High Voltage Engineering , Solar Energy Utilisation , Pulse – Width Modulation Dc – Dc Power Converters , Power Electronics , Power System Engineering , Switchgear & Protection , A Course In Electrical And Electronics Measurement And Instrumentation , Linear Integrated Circuits , Op-Amps And Linear Integrated Circuits , Utilisation Of Electric Power , Utilisation Of Electric Power , Electrical Machinery , Electric And Hybrid Electric Vehicles , Electricand Hybrid Vehicles , Electric And Hybrid Electric Vehicles :Design Fundamendals , Stepping Motors And Their Microprocessor Controls , Brushless Magnet And Reluctance Motor Drives , Electric Power Train Energy Systems, Power Electronics And Drives For Hybrid ,Electric And Fuell Cell Vehicles , Neural And Fuzzy Logic Control Of Drives And Power Systems , Electric And Plug In Hybrid Vehicle Networks Optimization And Control , Electric Vehicle Modern Technology And Trends , Electric And Hybrid Electric Vehicles , Emerging Power Converters For Renewable Energy And Electric Vehicles Modelling,Design, Annd Control , Calculus: Early Transcendentals , Calculus,Volume I And Ii , Differential Equations , Advanced Engineering Mathematics , Linear Algebra , Linear Algebra – A Geometric Approach , Multivariable Calculus , Cartesian Tensors,An Introduction , Riemannian Geometry- Concepts, Examples And Techniques , Analytical Geometry, 2D And 3D , Introductory Combinatorics , Advanced Mathematics For Engineering Students Vol Ii &Iii , Differential Equations With Applications And Historical Notes , Fundamentals Of Applied Probability And Random Processes , Probability, Random Variables And Random Signal Principles , Numerical Analysis , Introductory Methods Of Numerical Analysis , Elementary Number Theory With Applications , Coding Theory – A First Course , Contemporary Abstract Algebra , Topics In Algebra , Fundamentals Of Mathematical Statistics , Numerical Methods In Engineering And Science , Miller And Freund’S Probability And Statistics For Engineers , Linear Algebra, Signal Processing And Wavelets- A Unified Approach
Contract Date: Aug 12, 2025 Contract Value : 1.78 Lakh
Government Departments No of Bidders 3
46.
Housing Urban and Rular Development #7667705 AOC
Tender For Construction Of New Library At Indra Nagar Chennai; 1 DISMANTLING WORK 2 Dismantling & removing the existing Reinforced Cement Concrete work etc., by using required mechinaries including stacking of steel bars and disposal of unserviceable material within 50m lead, labour charges, as per direction of Engineer in charge. 3 Dismantling brickwork manually by mechanical means including stacking of serviceaboe material and disaposal of unservice material within 50 meters lead as per direction of Engineer in charge.. 4 Dismantling , removing and carefully stacking Doors & windows including removal of frames,hinges and fastenings etc., complete complying with standard specification and as directed by the departmental officers at site of work. 5 DismantlingFloor finish & dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs 6 Carting away surplus excavated earth available with in the campus is to be carted to a lead of within 10 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge. 7 Dismantling & removing the existing Plain Cement Concrete work etc., by using required mechinaries and disposal of unserviceable material within 50m lead, labour charges, as per direction of Engineer in charge. 8 CIVIL WORKS 9 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size bouldersand Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete SS.20B 10 cum 10 Supplying and filling in foundation andbasement with excavated soil other than sand in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 11 excavated soilrefilling- foundation 12 cost of earth anf filling 13 Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 14 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 15 Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive ofgiving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12to a depth of 8 in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc., 16 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc.,Rate to include all materials, labour charges, wastages ,placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by theClient / Engineer-in-charge. 17 Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members 18 Reinforced cement concrete Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members 19 For plane surfaces such as recangular or square columns, sunshades, top and bottom slab of boxing, kitchen platform, loft and such other structural members 20 Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, retainning wall drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge The rate including cost of all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by theEngineer-in-charge 21 FOUNDATION AND BASEMENT 22 GROUND FLOOR 23 FIRST FLOOR 24 MEZZANINE FLOOR AND HEAD ROOM 25 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required.Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 26 Supply and constructing Fly ash Brick masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure usingFly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 27 FOUNDATION AND BASEMENT 28 Ground floor 29 First floor 30 mezzanine floor 31 Terrace floor parapet 32 compound wall 33 Supply and constructing Flyash Brick partition wall 115mm thick in Cement Mortar 1:3 (one cement and three M sand) 11.50 CM thick using usingFly ash Bricks of size 230x110x75mm including both side plastering with CM 1:5 12mm thick and usinghoop iron reinforcement if found necessary and hoop iron shall be supplied to the department at free of cost etc., complete as directed by the Engineer in- charge. 34 GROUND FLOOR 35 FIRST FLOOR 36 Providing and laying weathering course on terrace in brick jelly limeconcrete in ratio 1:2 ( I lime: 2 brick jelly ) the size of the brick jelly should not be more than 25 mm and not be less than 20 mm . The rate includes the cost of all material and lanour involved .provide and lay one course of first quality pressed clay tiles 200x 200 x 20 mm thickness size of approved brand for terrace floor and sides over a bed of cement mortor mix 1:3 with water proofing compounded added rate to include for pointing jonts with neat cement . 37 WATER PROFFING TOILETS AND OPEN TERRACE- Water proofing treatement for top surface and all side of sunken porton in the followingsequences including all labour . Materials , tools lead and lifts etc, a) cleaning of RCC remove dust completely , b). supply and application of cm 13 mixed with niobond SBF latex or equivalent polymer modified high quality cmulsionas a coving at the corners of floor and the vertical surface in the sunken area and between floor and walls in he remainig area c) apply first coat of brushbond RFX or equivalent acrylic polymar modified cementitious water proofing membrane coating on the prepared mofified cementitious waterproofing membrance coating on the prpered surface in a contionous film on the sunken floor area vertical sutfaces up to finished foorlevel , the coating also continued on the inner surfaces of the pipe penetration holes . 38 Finishing the top of roof with one course of Solar Reflective ceramic tiles of size 305 mm x 305 mm x 7 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 39 FRONT ELEVATION - Construction of 4½thick walls usingavailable good wire cutbricks with strength 30 - 50 kg sq cm of super structure above plinth level in cement mortor 1:4 ( 1cement :4 coarse sand ) including al leads and lifts for all floors supply and placing of 25 mm x 16 gauge hoop iron for every fourth course half brick masonry wall and providing lateral supports if length of the wall exceedinf 3m as per specifications including curing , scaffolding all materials in labour etc . complete at all floors levels incuding the cost of cement 40 Providing two legged scaffolding using 15cm dia casuarinas post of 4.0 m over all length of (3 M Height+0.5 M over all length (3.0M height +0.5m projection +0.5m in to the ground ) the distance between the two rows being 1.25M and the spacing of posts being 2.0M in both the rows with two horizontal posts with 0.5M overlap on either side and braces at 2.0M centre to centre including longitudinal and traverse middle braces to step up and transverse middle braces to step up and providing a plat form with country wood planks of 40mm thick and 1 M width ,etc in a complete form using coil and nails (Rate for an initial height of 3.0M and length of 1 M) 41 Upto 3 M Height 42 For every additional height of 2.5 M (3m - 5.50m) 43 For every additional height of 2.5 M (5.50m -8.00m) 44 For every additional height of 2.5 M (8m -10.5m) 45 For every additional height of 2.5 M (10.5m -13m) 46 Supplying and fixing Shade Net (Green Net) for under construction of high rise building M-0298 47 FINISHING WORK 48 Special ceiling plastering and finishing all RCC exposed surfaces such as RCC slabs, sunshades, canopies, stair case steps, landing slabs etc with CM 1:3 (One cement and three sand) 10mm thick including hacking the surfaces and providing necessary CM nosing, beading as per size specified wherever necessary using the same mix etc., complete complying with standard specification and as directed by the Departmental Officer.S.I. 309--TNBP No. 55& 56 49 Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications 50 Plastering with cement mortar 1:4 (One Part of Cement and Four part of Plastering Sand (P- Sand)) 20mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309) 51 Supply and laying with best quality the following materials of Machine Polished granite slabof 18 mm thick (Fine Polished Steel Grey Granite Slab) including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 52 Polishing and Nosing the Granite Slab To Half Edge to round shape and finishing the surface neatly etc. complete complying with standard specification as directed by department officers 53 JOINERIES 54 ABS DOOR / EQUIVALENT Specification:Providing of 35mm thick factory made pre-laminated ABS (Acrolynitrile Butadiene Styrene) Door Shutter moulded in different designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x 32mm, reinforced by 32 x 32mm - 2 Nos., for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm. PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of steel coated butterfly hinges - 3 Nos., for each shutter and ISI make SS round lock complete for finished item of work, complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work. Design Pre-laminated Door 55 Providing and fixing 35mm thick Factory made Prelaminated ABS (Acrolynitrile Butadyne Styrene) Sliding Door shutter moulded ofdifferent designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32x 32mm - 2 nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32 mm thick high density craft paper honey comb board, sandwiched on both sides with prelaminated ABS sheetthickness of1.5mm .PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of steel coated butterfly hinges-3 nos for each shutter, D SS pull handle 200 mm on both sides and SS tower bolt on one side with ISI makecomplete for finished item of work, complete complying with the standard specification.The door shall be shall move with dicast zamak rollers with ball bearings fixed over the powder coated aluminium sliding track of 2.40m length and bearing capacityof 60/80 kg.Adjustable end stop, floor guide andtwo way entry hanger bracket with locking arrangements shall be provided. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging,fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 56 Flush doors : Supplying and fixing single leaf flush door 32/30mm thickness poth side commercial ply and approved brand Century/ Merino/ Greenlam with T.W.frames of size 100x75mm at side verticals and top, 6Nos.of iron hold fast fixed in C.C.1:2:4 and 3Nos.of butt hinges 125mm long including wind appliances furniture iron fittings 2Nos.of iron pad lock 15cm long for locking arrangements and fixed in position as directed during execution.(ISI STD) Rate as per GCC 2023-2024 - Building 57 Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile arereinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also itoperates as handle.The corners and joints should bewelded and cleaned.Radiations free pin headed plain or rown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action,security protective hinges, strong lockingsystems and asper size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on wor 58 Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on wor 59 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 60 Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Executive Engineer before use on work 61 Providing Ceramic tiles of size 305 x 305 x 6mm flooring approved make and quality with plain/colourwith base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., 62 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 63 Painting the new plastered walls with two coats for Interior Plastic Emulsion paint approved quality and colour over a priming coat, with two coats of wall putty including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 64 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 65 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 66 Supplying And Fixing Rubber Moulded Interlocking Blocks Against Available Edge Restraints 80 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro- Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To- Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (MSand)). 67 Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges et 68 Curtain Wall Glazing System 69 Structural Glazing (Curtain wall Glazing System) : Supply and fixing of (curtain wall Glazing System) having main framework of mullions and transoms made out of (64mm x 57mm x 2mm) sections for frame work designed extruded. Aluminum section should be Black colour anodized with 50 micron, mullion fixed to the beam / Column through adequately designed MS Anchor brackets expansion fasteners as required. System design to strictly considered for thermal movement, air infiltration, water preparation, seismic movement and structural movement including 6mm ST 167 Reflective Glass+1.52 PVB+6mm Clear Laminated Toughened Glass, MS Support Work with necessary 70 Smooth Finish Cement Texture + Archi Concrete + Base Coat Texture +Top Coat Design Texture + Standing and Smoothing + Warter Base Pu Coating 71 Supplying of locally made teracotta machine pressed wall cladding (Size: 230x75x16mm) & installation of the same with Sait-Gobain (Weber) make tile adhesive and sandbased grout at 10 mm spacing. 72 Supply & Fixing of Handrail using Modular Glass Railing System for Top & Bottom, 6mm Clear+1.52 PVB+6mm Clear Laminated Toughened Glass Polish with necessary accessories. 73 PLUMBING & SANITARY WORKS 74 Providing & fixing PVC RAIN WATER DOWNFALL PIPE of 110mm dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps,screws nailsetc.,complete complyingwithstandardspecification.Therateis inclusive of cost of removable iron gratings of appropriatesize.ThesizeofTeakWoodplugsusedis 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of U clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] 75 Supply of 5000 ltrs Pvc Sintex water tankincluding cost of materials , conveyance and fixing charges etc., 76 Water supply work 77 InternalWaterSupply-CP.V.C.Pipes(6Kg/SqCm) SupplyinglayingandjointingP.V.Cpipes(6Kg/SqCm) of approvedqualityandbestvarietyconformingtoI.S.S& withI.S.Imark,ofthefollowingsizesincludingcutting, FixingtoPVCspecials usingAdhesivebutexcludingcost ofsuchspecialsandfixingtowallwithnecessaryteak- Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantledportions to original conditionwith necessary brick work and plastering wherever necessary with necessaryscaffolding charges. 78 20mm dia 79 25mm dia 80 32mm dia 81 Supplying & fixing in position first quality & approved variety of 50mm dia C.P.V.C BallValves ( Heavy type ) withI.S.I. Mark of the following size including cost of Shellac, thread etc.,including labour for cutting & threading ofPipes etc., complete complying with standardspecifications for both internal & external water supply arrangements. 82 25mm dia 83 32mm dia 84 INTERNAL & EXTERNAL SEWAGE WORK 85 SupplyingandfixinginpositionbestqualityP.V.Csoil/ wastepipes (6KSC) ofvarious sizeshaving ISImark and providingleakproofjointsincluding fixingtothewall with P.V.C/ M.S clamps etc., and making connection to all sanitary fittings,dismandlingmasonry/R.C.C.works wherevernecessaryandmakinggoodthedismandled portiontotheoriginalcondition,complyingwith standard specifications. 86 75mm dia 87 110mm dia 88 TOILET FITTINGS 89 Supplyingandfixinginpositionbestqualityapproved makewhiteglazedearthenwarewashhand basinof size 550 X 400 mm with a pair of cast iron brackets, including costof 15mm diametre brasschromium plated piller tape,32 mm diametreC.P. Waste union, 32 mm diametre P.V.C.waste pipe with rubber plugand chain,15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basininthewallinpositionwithapairofC.I.brackets withteakwoodplugsandscrewsandgivingnecessary water supply connection and paintiung the brackets with twocoatsofpaintoveraprimimgcoatofanticorrosive paintincludingtestingforleackageetc.,complete complying with standard specifications 90 Fabricating, Supplying, installing and testing best quality approved / equivalent make of stainless steel sink of size 600x600x200mm made using 2.00mm thick stainless steel sheet 304 grade. The sink is to be fixed over a concrete platform. Sink is to be fitted with 32mm dia CP waste coupling, 32mm dia heavy duty waste hose with extension pipe, 3 no of long body 15mm CP screw down Tap, CP inlet connection tube , CP wall flange, including necessary brackets etc complete complying with standard specification and as directed by the Department officers. 91 Supplyingandfixinginpositionindianmakebewelled edgemirror of approved quality and brand of size 600 X 450mm wth necessary plastic back, PVC frame with bottom stand of approved colour with brass screws,rawal plugsetc.,completecomplyingwithstandard specifications 92 Supplying and fixing best approved quality C.P.Soap Tray ofsize150mmX100mmincludingcostofTeak Woodplugs,brassscrewscompletecomplyingwith standardspecifications. 93 Supplying and fixingbest approved quality Brass C.P / Al anodisedTowelrail600mm.longand20mmDiameter withbracketsofsamematerialincludingcostofTeak- Wood plugs and C.P.Screws etc., complete complying with standard specifications 94 Supplingandfixinginposition 15mmdiameterbrass/ C.Pscrewdowntap/pillartap/swannecktap(heavy duty)ofapprovedmakeconformingtoI.S.specifications and quality including cost of shellac, thread etc.complying withstandardspecificationsandincludingcuttingand threading wherever necessary. C.P screw down tap 95 Supply and fixing in position whiteEuropean Water Closet of approved make with Porcelain low level flushing tank 12.5 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directedby the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works. 96 Supplyingandfixingthebestqualityapprovedmakeof bip cock with C.P. health faucet wall hook one metre long flexible tube, angle cock with wall flange including cutting and making good the walls wherever required etc.complete,complyingwithstandardspecificationand as directedbytheDepartmentofficers.Thequalityand make of health faucet should be got approved by Executive Engineer before use on work. 97 Supplying and fixing of White Glazed Porcelain Oval Shape Special Type Urinal of size 382 x 398 x 601mmwith all accessories such as 32mm dia Bell Mouth PVC Connection,15mmdiaGMWheelValue,15mmdia‘B’ Class GI WasteWater Pipe, 15mm diaNylon Connection, 15mm dia Brass Nipple etc. 98 Supply and fixing of PVC. Nahini / Floor Trap with stainless Steel Gratings- 100 mm x 75 mm including all charges etc, complete as per standard specification. 99 Supplying & fixing in position 150 X 100 mm square mouth P or S trap stone ware Gully trap A gradewith cast iron double gratings of size 150 X 150 mmwith C.I. air tight cover with frames of size 300 X 300 mm at bottom & top respectively with necessary earth work excavation, laid over a bed of brick jelly cement concrete 1:3:6, 150 mm thick using 20 mm size broken brick jelly including necessary brick work & plastering, &including dismantling masonry wherever necessary & redoing the damaged portions to the original condition & by using cement concrete 1:3:6 using 20 mm stone jelly for fixing the Gully trap & giving connections to the stone ware sewer line etc., complete, complying with standard specification. (The stone ware gully trap should be got approved by the Executive Engineerbefore use on works ). 100 Constructing brick masonry manhole with second sort Solid Blocks in CM 1:5 (one of cement, Msand) including earthwork excavation and sand filling for a depth of 150mm top cover slab with CC 1:2:4 (one of cement, two of sand, four of graded aggregate)20mm nominal size for fixing C.I Frame, including shuttering, reinforcement foundation concrete 1:4:8 (one of cement, four of sand, eight of graded aggregate 40mm nominal size) 100mm tk., plastering inner, outer and other exposed surface with 15mm tk., cement mortar 1:3 (one of cement, three of sand) and finishing with a floating coat of neat cement with water proofing compound as per specification, making channelsin CC 1:2:4 (one of cement, two of sand, four of graded aggregate) neatly finished including fixing C.I. Cover and frame, C.I. Rungs etc., complete complying to standard specification. 101 Supply and fixing RCC precast slab manhole cover SFRC of 50mm thick and required size 900mm x 900mm made in CM 1:3 Ratio both direction including cost and conveyance of all materials, labour and transportation etc complete complying with standard specification. 102 BORE WELL 103 Drilling of 12 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shownincluding construction of mud pit etc. using only calyx rigs. 104 300mm (As per Twad Schedule Item No: 14f, P.No: 306) 105 150mm / 165mm (As per Twad Schedule Item No: 14a, P.No: 305) 106 Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. 107 Upto 60 m depth ending below ground level 108 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992 ( 1.1 (4,6,3), P.No: 22, Twad 109 200 mm dia CS 110 200 mm dia RS 111 150 mm dia RS 112 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. ( As per S.item no: 13a , p.no: 201) 113 200 mm dia CS 114 200 mm dia RS 115 150 mm dia RS 116 Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock. upto 30m rock level 117 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directedand conducting yield test by V notch method. 118 Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge. 119 Supply ,erection and testing & commisioning of 2HP submersible pumpset in theOpen borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge. 120 Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trailrun for 10 days. (TWAD 17C) 121 Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO)Standards with following accessories.(a) MS Skid - 1 No.(b) Media 11054 No. Vessel with 20 nb Multiport Valve (withMedia Pubble and Fine Sand and Activated Carbon Filling) set(c) Feed Pump 0.50 HP – 1 No.(d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic(USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No.& Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., LowPressure Switch - 1 No., Level Switch - 1 No. & NecessaryCPVC Pipes and Fittings.The system shall be provide with Two Panel Control Systemwith necessary Stainless Valves and Fittings and Float Controletc. The rate should be inclusive of all civil works, wherevernecessary to install the System in position and intact. 122 250 Ltr (M-0721) 123 Construction of Modular type RWH Structure capacity of 4.32 cu.m by usinginfiltration modules of size 800 x 800 x 360 mm and side wall with infiltration modules of size 800 x 360 x 25 mm includingearthwork excavation in bitumen/concrete roads to a size of 1200 x 1200 x 3000 mm and providing base plate, Geo - textile 400mm - 200 micron, Fine filter media 12mm thickness, Coarse filter media 20mm thickness, FRP of 700x700mm (clear opening 600x600mm) (Grating cover with Frame - Medium duty 10 MT), including all labour charges, carting away and drilling bore well 150mm dia upto a depth of 3m with 125mm dia Blue slotted PVC Pipe., complete. (Model 6) 124 INTERIORS & FURNITURES 125 Lending Counter with Side Table - F/installing in place Lending Counter of 600mm wide top with Side table storage of 450mm wide top, the table top, side verticals, midshelves and front panel of side table made of 19mm thk. HDHMR sheet. The front panel of the lending counter of height 1050mm is made of double-skin 19mm thk. HDHMR sheet cut to shape as per design. The table edges are finished with 6mm thk. matching pine wood beading with rounded edges. The table front, top, side surfaces and storage shutter fronts are finished with PU Matt polish of approved shade. The table and storage internal surfaces are finished with 0.8mm laminate of approved shade and make and inner edges finished with matching 2mm edgeband. 8mm thk. Lacquered glass (2.1m x 0.6m) - Saint Gobain make - of approved shade is fixed on top of table. The table size is 2.1x0.6x0.75m & 1.0x0.45x0.75m (as per Architects drawing) 126 Librarian Table with Side Table - F/installing in place Librarian table of 600mm wide top with Side table of 600mm wide top, the table top, side verticals, midshelves and front panels made of 19mm thk. BWR ply. The table front, top, side surfaces and storage shutter fronts are finished with 4mm Veneer of approved shade and make on all sides. The outer edges are finished with 6mm thk. pine wood beading with rounded edges. The table and storage internal surfaces are finished with 0.8mm laminate of approved shade and make and inner edges finished with matching 2mm edgeband. The veneer and wooden beading surfaces are finished with PU Matt polish of approved shade and make. 8mm thk. Lacquered glass (2.1m x 0.6m) - Saint Gobain make - of approved shade is fixed on top of table. The table size is 2.1x0.6x0.75m & 1.2x0.6x0.75m (as per Architects drawing) 127 Magazine Rack (400mm dia) - F/installing in place magazine rack, 200mm ht. hollow base and 650mm ht. hollow top with 2.40m ht. open storage in the middle. The hollow top and base made of 15mm thk. MS round pipe framework fitted with 5mm thk. MS round plate on top and bottom and covered with 3mm thk. MS sheet skin on all round. The open storage is made of 15mm thk. MS round pipe framework covered with 3mm thk. MS sheet skin on all round with cut-outs as per designand fitted with 5mm thk. MS round plate midshelves at heights as per design. The hollow top & base and middle open storage are all welded together in place and finished with powder-coated finish of approved shade. The metal edges to be properly sanded,smoothened and curved to avoid discomfort. The magazine rack size is 0.4 dia x 3.25m height (as per Architects drawing) 128 Open Box Storage type Wall Rack in Kids Seating (300mm depth) - F/installing Wall racks made of open storage boxes stacked on top of the other and secured in place with necessary adhesives and hardwares. The open storage boxes top, front, and side verticals fabricated out of 19mm thk. HDHMR sheet with 38mm thk. front fascia. with 9mm thk. HDHMR backsheet. The box edges are curved with 9mm thk HDHMR sheet with necessary wooden framework. The entire unit is finished with PU Matt polish of approved shade. The size of the boxes are 1.15x0.35x0.30m - 30nos and 1.30x0.35x0.30m - 15nos. 129 900mm x 300mm Depth Metal Wall Racks in Reading Area - S/installation of open Metal wall racks with horizontal mid-shelves in powder-coated finish of approved shade as per design. 130 1000mm x 300mm Depth Metal Wall Racks in Reading Area - S/installation of 2.1m height open Metal wall racks withhorizontal mid-shelves in powder-coated finish of approved shade as per design. 131 1150mm x 300mm Depth Metal Wall Racks in Reading Area - S/installation of 2.1m height open Metal wall racks withhorizontal mid-shelves in powder-coated finish of approved shade as per design. 132 1000mm x 450mm Depth Metal Wall Racks in Reading Area - S/installation of 2.1m height open Metal wall racks with vertical divider to access books from both sides of rack separately with horizontal mid-shelves in powder-coated finish of approved shade as per design. 133 Janitor Storage in Toilet Lobby (350mm depth & 2100mm height) - F/installation of janitor storage box made of 19mm thk. WPC sheet with 9mm thk. WPC sheet backing. The shutter and mid-shelves are made of 19mm thk. WPC sheet. The outer surfaces are finished with 1mm Laminate of approved shade and internal surfaces are finished with 0.8mm Laminate. The edges are finished with 2mm thk. matching edgeband with rounded edges. 134 PANELINGS & PARTITIONS 135 Feature Wall behind Lending Counter - S/installation of feature wall behind Lending counter made by providing 450mm dia perforations on existing brick wall at even spacing as per design. Clay pots are used to fill in the perforations at certain places as per design. Few perforations are used for fixing photographs with the help of 19mm thick BWR plywood backing for support. The balance perforations are left as it is. The entire feature wall surface including the clay pots is prepared with a layer of touch-up putty with necessary sanding and finished with 2 coats of Asian Paints make Royale emulsion of approved shade as per design. 136 Kids Seating with Levels in Reading Area - S/fixing in place the kids leveled seating of two levels 300mm and 600mm surrounded by 300mm deep x 650mm high support base for fixing open box book storages on the sides and back. The frames for the seating levels and surrounding storage support base are made with aluminum tubular sections 2 x 1 size and appx 1.5mm minimum wall thickness, vertical members at a spacing at 20 c/c except the end panels, where the spacing maybe less than 20 as per site condition. Horizontal members shall be fixed at top, bottom and middle. the curved wooden steps made from wooden framework as per design. The aluminum frames shall be tied in position by 1 1/2 X 1 1/2 X 2.5mm thick aluminum angles, cleats of 1 1/2 long and screwed with four screws per angle by CP metal pan headed screws. 2nos-1.2m dia x 0.45m deep cut-out is given on top of the 600mm seating level for recessed seating and sides covered with 19mm thk. HDHMR sheet. The top, front and sides of all the aluminium and wooden frame work is cladded with 19mm thick HDHMR sheet with 6mm thk, HDHMR sheet used for curved surfaces. The entire unit is finished with PU Matt polish of approved shade and color. Cost to include supply and installation of seating & back cushions (10nos) inshapes as per design made of 100mm thick PU foam and cladded with fabric of approved shaded as per Architects selection. 137 Terracotta Wall Tile Cladding in First Floor Reading Area - S/installing in locally made terracotta machine pressed wall cladding (size: 230x75x16mm) on existing rough plastered wall surface in pattern as per Architects design using Saint-Gobain (Weber) make tile adhesive and sandbased grout at 10mm spacing. 138 10mm Toughened Glass handrail - S/fixing in place 10mm toughened glass handrail - Saint Gobain make - with MS top rail as per detailed drawing and specifications including flats, plates, anchor fasteners required complete with necessary hardwares. 139 Fluted Glass Divider for Tables in Reading Area - S/installation of 10mm thk. Fluted glass divider with rounded edges on top fixed on table top with U clamp as per design. 140 CEILING & WALL FINISHES 141 Gypsum false ceiling - Supplying and erecting the false ceiling with gypsum board suspended to the ceiling with commercial GI sections and suspenders as per the manufacturer’s specification and procedure metal expansion fasteners to be used for fixing soffit cleat to roof slab or beams at a distance of not exceeding 1220mm C/C. Main channel spacing at a maximum distance of 1220mm C/C max with soffit cleat. Perimeter channel fixed to ceiling section at 457mm C/C (max) to the above frame work, fixing one layer ofSaint Gobain make 12.5 gypsum board screw fixed to the underside of the suspension grid, tapered edge board tapered edge boards tapered fibre tape and filled to give a smooth seamless ceiling all as per manufacturer’s specification and procedure complete. 142 True / Gypsum False ceiling painting - Preparing the ceiling surface with necessary scraping and application of 2 coat putty, 1 coat primer and 2 coats of finishing premium emulsion paint - Asian Paints make - to achieve a smooth painted surface. 143 Ceiling Mural in Mezzanine Floor - Providing a ceiling mural of selected design in Royale emulsion paint finish - Asian Paints make - on Mezzanine floor false ceiling as per design. 144 Wall painting - Preparing the walls with necessary preparatory works including application of 2 coat putty, 1 coat primer and 2 coats of finishing Royale emulsion paint - Asian Paints make - to achieve a smooth painted surface. 145 Wall painting - Preparing the walls with necessary preparatory works including application of 2 coat putty, 1 coat primer and 2 coats of finishing Royale enamel paint - Asian Paints make - to achieve a smooth painted surface for application of wallpaper. 146 Wooden Rafter False Ceiling above Lending Counter in Ground floor Entrance Area - S/installation of wooden rafter ceiling above Lending counter the rafters made of 50mm x 100mm ht. Aluminium pipes cut and finished to shape in wooden powder coated finish as per design and fixed to the base made of 19mm thk. Ply suspended from the true ceiling with commercial GI sections and suspenders as per the manufacturers specification and procedure metal expansion fasteners to be used for fixing soffit cleat to roof slab or beams at a distance of not exceeding 1220mm C/C. Main channel spacing at a maximum distance of 1220mm C/C max with soffit cleat. Perimeter channel fixed to ceiling section at 457mm C/C (max) to the above frame work. The Wooden ceiling is finished with 1mm Laminate of approved shade and make to match the aluminium rafters. 147 Wooden Rafter False Ceiling above Reading Area in First floor - S/installation of wooden rafter ceiling above Reading area, the rafters made of 50mm x 100mm ht. Aluminium pipes cut and finished to shape in wooden powder coated finish as per design and fixed at an angle with even spacing to the base made of 19mm thk. Ply suspended from the true ceiling with commercial GI sections and suspenders as per the manufacturers specification and procedure metal expansion fasteners to be used for fixing soffit cleat to roof slab or beams at a distance of not exceeding 1220mm C/C. Main channel spacing at a maximum distance of 1220mm C/C max with soffit cleat. Perimeter channel fixed to ceiling section at 457mm C/C (max) to the above frame work. The Wooden ceiling is finished with 1mm Laminate of approved shade and make to match the aluminium rafters. 148 Wooden False Ceiling for Stretch Ceiling in Reading Area - S/installation of wooden false ceiling suspended with commercial GI sections and suspenders as per the manufacturers specification and procedure metal expansion fasteners to be used for fixing soffit cleat to roof slab or beams at a distance of not exceeding 1220mm C/C. Main channel spacing at a maximum distance of 1220mm C/C max with soffit cleat. Perimeter channel fixed to ceiling section at 457mm C/C (max) to the above frame work, fixing one layer of 19mm thk BWR ply screw fixed to the underside of the suspension grid. Another layer of 6mm thk HDF is fixed over the plywood layer. The HDF surface is finished in premium emulsion paint finish - Asian Paints make - after putty and necessary surface preparation works. Proper supports to be given to handle fixing of Stretch False ceiling as shown in design fitted over the wooden false ceiling with necessary hardwares. 149 Stretch Ceiling in Reading Area - S/installation of Stretch Ceiling of Iceil / Euroceil / Equivalent make with white translucent film 75%stretched over Metal framework custom shape as shown in design suspended from wooden false ceiling. It shall consist of custom made Stretch false ceiling to fit exact dimensions with aluminium supports. The ceiling must be stretched and hooked into aluminium rails. Aluminium rails insuring good rigidityto be fixed to the wooden false ceiling at the specified level. The stretch ceiling to have Non-flammable fabric EURO CLASS B-S2 d0 in the European classification of reaction to fire with 10 years warranty. It shall include supply and installation of Neutral White Philips LED lighting with compatible LED driver and wiring in the stretch ceiling box. The lights to be placed in such a manner that no dark patch appears or zebra pattern appears. Once lights are installed stretch ceiling to give uniform output with required lux levels as per Architect. Rates shall be inclusive of installation of stretch ceiling and LED lights by companys installers. Rates shall also include the cost of transportation of materials and also the travellinghalting and all other misc. expenses of companys certified installer. 150 Pelmet for Blinds & ACs in Laminate finish - Supply and fabrication of 150mm high pelmets for blinds and 300mm high pelmets for AC units made of 19mm BWR ply to size and shape as per design. The pelmet is finished with 1mm thk. Laminate of approved shade and make on the exposed sides and edges finished with 2mm thk. matching edgeband. 151 Wallpaper in First floor Reading Area - S/installation of designer wallpaper of selected design in smooth finish - Asian Paints or Equivalent make - on wall surface after required surface preparations with necessary adhesives as per design. 152 DOORS 153 12mm Toughened Glass Door embedded in MS Frame ( 1.0m x 2.4m - 1no ) - P/fixing of single pane 12mm toughened glass door - of Saint Gobain make - embeded in 50mm x 50mm MS powder-coated frames of approved shade in Geze or equivalent make complete with necessary fittings - floor spring, door closer, 600mm ht. H-handle, locks etc. of Geze / Ozone / Dorma XLC make. 154 12mm Toughened Glass Door embedded in MS Frame ( 1.50m x 2.4m - 3nos ) - P/fixing of double pane 12mm toughened glass door - of Saint Gobain make - embeded in 50mm x 50mm MS powder-coated frames of approved shade in Geze or equivalent make complete with necessary fittings - floor spring, door closer, 600mm ht. H-handle, locks etc. of Geze / Ozone / Dorma XLC make. 155 12mm Toughened Glass Door embedded in MS Frame ( 1.80m x 2.4m - 3nos ) - P/fixing of double pane 12mm toughened glass door - of Saint Gobain make - embeded in 50mm x 50mm MS powder-coated frames of approved shade in Geze or equivalent make complete with necessary fittings - floor spring, door closer, 600mm ht. H-handle, locks etc. of Geze / Ozone / Dorma XLC make. 156 WPC Door with Vision panel ( 1.0m x 2.4m - 1no ) - P/fixing of 100x45mm Cellular hollow WPC door frame with rebate of 37mm paintedwith color of approved shade. The frame shall have 9mm deep groove for front architrave fixing. Outer layer of Cellular frame shall be 5mm thick and other 2 layer shall be of 4mm thickness. The front architrave shall be of 45 x 18mm hollow WPC section painted with color of approved shade. 30 x 12mm rear architrave, having width of 30mm and thickness of 12mm painted with color of approved shade. The frame and architraves shall be supplied in 3 parts as per customized size assembled with miter joint. The door frame having material density of 990kg/m3 (IS 2380 - part 3), shore hardness (D) of 62 (ASTM D2240), Moisture content less than 0.01% and water absorption of less than equal to 0.2% (IS 2380 - part 16). Providing 32mm shutters, all four edges of shutter shall be made of 55mm dried Pinewood frame. The frame to be fixed using PU foam and anchor fastners and requisite hardware. The complete shutter finished in paint finish of approved shade. The shutter to be fixed on the frame with necessary hardware fittings incl. hinges, locks, handles, floor spring and Door closer with standard arm of Hettich / Ebco / equivalent make. 157 LOOSE FURNITURE (cost to include installation charges) 158 Table with Metal Legs in Ground & First Floor Reading Area - Supply and installation of Wooden table, 38mm thk. Top made of doubly pressed 19mm thk. BWR ply and finished with 3mm Veneer of approved shade and make. The edges to be finished with 6mm thk. wooden beading with rounded edges. The table top is finished with duco Matt polish of approved shade and color. Metal legsfabricated of 50x25mm and 100x25mm MS frames to match design as per drawing and finished with powder-coated finish of approved shade as per design. The legs are fixed at the ends of the table top as per drawing. 159 1500mm (L) x 1050mm (D) 4 Seater Table 160 1500mm (L) x 1200mm (D) 4 Seater Table 161 750mm (L) x 1050mm (D) 2 Seater Table 162 Table with Metal Legs in Reading Area. 2dia Wire manager to be provided on top - Supply and installation of Wooden table, 38mm thk. Top made of doubly pressed 19mm thk. BWR ply and finished with 3mm Veneer of approved shade and make. The edges to be finished with 6mm thk. wooden beading with rounded edges. The table top is finished with duco Matt polish of approved shade and color. Metal legsfabricated of 50x25mm and 100x25mm MS frames to match design as per drawing and finished with powder-coated finish of approved shade as per design. The legs are fixed at the ends of the table top as per drawing. 2 dia ss wire manager - required nos provided on top as per drawing. 163 2000mm (L) x 1200mm (D) 4 Seater Table 164 1000mm (L) x 1050mm (D) 2 Seater Table 165 Medium-back Mesh Office Chairs - Supply amd installation of Medium backmesh chairs with Gas lift, Synchro tilt mechanism and foam cusion seating installation complete. The backrest, handles, seat frame and mesh to be in white color and the seat cushion to be in Grey color of approved shade as per design. 166 Round Pouff Chairs near Metal Racks - Supply and installation of round pouff seating in all floors of 450mm dia and 450mm height as per drawing with metal frames and PU molded cushion upholstered with 2 foam and fabric of approved texture, shade and color. 167 2-Seater Medium-back Sofa with Metal Legs in Reception Area - Supply and installation of medium-back 2seater sofa with cushion handrest and metal legs near ground floor Lending counter with 40 density foam for handrest, back and seat of size and design as per drawing and finished with fabric of approved texture, shade and color as per design. Basic cost of fabric Rs.150-200 per metre. MS legs in shape as per drawing and in black powder coated finish are provided as per design. 168 BOUGHT-OUT ITEMS (cost to include installation charges) 169 Mosquito Catcher - Supply and installation of 240W wall / floor mount corded commercial electric flying insect killer machine with catchment tray. 170 Assorted Wall Paintings - Supply and installation of decorative artwork printed in canvas / high quality thick premium glossy photo paper and encased in wooden frames of approved design, shade and color with 4mm thick glass in front of artwork as per design. 171 Photo Frames behind Lending Counter - Supply and installation of photos of tamil leaders printed in high quality thick premium glossy photo paper and encased in wooden frames of approved design, shade and color with 4mm thick glass in front of photos as per design. 172 Entrance Floor Mat - Supply and sinstallation of 2m x 1m Floor mat for the front entrance area on the floor. 173 Water dispenser - Supply, installation, and commissioning of Blue Star, model no.BWD3FMRGA or equivalent, hot ,normal & cold dispenser machine with refridgerator bottled water dispenser of 20L capacity with drip tray and other necessary accessories. 174 Wall Clock - Supply and fixing of wall mounted round/square Analog clockof approved design. 175 FIRE FIGHTING ARRANGEMENTS 176 Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Make: Apollo / Equivalent) 177 Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Departmental Officers 178 FIRE SAFETY 179 First Aid Box complete with all First Aid Medicines 180 Shock Treatment Chart fixed in glass frame 181 Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms 182 Danger Board as required by the Electrical Authorities 183 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS(5 set) 184 Hand Gloves 11KV Grade 185 Earth Discharge Rod 186 Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Departmental Officers 187 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 188 Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT /SAFETY FIRST / EQUIVALENT 189 FIRE ALARM 190 Supply, installation, testing and commissioning of Micro Processor based conventional 4 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply ,consisting 230/24 volt SMPS unit, 2Nos.of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. 191 Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard method sand as directed by the Departmental Officers.(Make: Ravel / Equivalent) 192 Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers (Make: Ravel / Equivalent) 193 Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., asper standard methods and as directed by the Departmental Officers. 194 ELELCTRICAL WORKS 195 LT CT TNEB METER BOX: 196 CT Metering Panel - Supply, installation, testing and commisioning of CPRI approved make of panel, cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars, internal wiring, colour coding, ferrules, Panel mounting MS channels, fasteners, etc., including all associated control wiring. 1set of 200/5A CT with TNEB Metering provision and 1nos of 200/5A CT for APFCR 197 250A Isolator Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of 250A TPN MCCB panel, cubicle type, Free standing, floor mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, 198 MAIN LT PANEL: 199 Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base frame, double internal earthing arrangements, 200Amps, rating TPN Copper busbars with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 200Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMMetering : 1 Set of RYB LED Indication lamps1 Nos. of Multifunction Meter with RS 4851 Set of Current Tranformers (200/5A, Cl-1), 1 No. 200/5A CT Outgoings: 2 Nos. 100A, 25kA, TP+N, TM MCCB with Ext. RHOM (APFCR & Spare)5 Nos. 63A, 25kA, TP+N, TM MCCB with Ext. RHOM (PDB-1,2&3, INVERTER & Spare)4 Nos. 32Amps DP MCBs (LDB-1,2&3 & SPARE) 200 APFC Panel: Supply, installation, testing and commissioning of 40 KVAR Automatic power factor correction panel ( APFC ) with 8 steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment for each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 8 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars, MPP type Power capacitors, with 10 KVAR x 3 nos.5 KVAR x 1 no. 2 KVAR x 2 nos. 1 KVAR x 1no. Contactors, MCCB’s, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc.,andAPFC Panel Installation, Testing , Commissioning and Transport Charges all inclusive. 201 Supply and fixing of 7 segment6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in each segment) and seperate provision for MCB / Isolators ( totally 18 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. withthe following on wall with earth connection only.i.63A 4P MCB- 1 no. ii.63A 4P 30MA RCCB/ELCB - 1 no. iii.63A DP MCB Isolator -3 nos. iv.6A to 32A SP MCB - 18 nos. 202 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 203 Supply and Laying of 3 1/2x 120 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 204 Supply and layingof 2 x 6 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting0.15metrelayerofsandand coveringthe cablecompletely withbricksandsandandrefillingtheearthto make good 205 Supply and Clamping of 3 1/2 core x 120 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. 206 Supply and Clamping of 3 1/2 core x 35 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. 207 Supply and Clamping of 3 1/2 core x 25 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. 208 Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection 209 Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection 210 Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection 211 Supply and fixing of brass cable gland for 2 x 6 sq.mm. PVC LTUG armoured cable with earth connection 212 Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 213 Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 214 Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 215 Supply and Run of 4 of 10 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigidpipe concealed inwall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 216 Supply and Run of 2 of 6 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigidpipe on wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copperwire with painting of suitable colour. 217 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion 218 Wiring with 2 x1.5 sq.mm.PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigidpipe on wall and ceiling and switch dropportion PVC rigid pipe concealed in wall with PVC accessories with Module GI switch boxin flush wall with 6A one way module switch with module front plate withcontinuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colourforOpen PVCLight point / fan point (for electronic regulator) ( 6 points / Coil)Higher End - PRIMARY POINTS 219 Wiring with 2 x1.5 sq.mm.PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigidpipe on wall and ceiling and switch dropportion PVC rigid pipe concealed in wall with PVCaccessories with Module GI switch boxin flush wall with 6A one way module switch with module front plate withcontinuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colourforOpen PVCLight point / fan point (for electronic regulator) ( 6 points / Coil)Higher End - SECONDARY POINTS 220 Wiring with 3 x1.5 sq.mm.PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed in wall and ceiling with PVCaccessories with ModuleGI switch box in flush with wall with 6A two way module switch with module front plate withcontinuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colourfor ConcealedPVC pipe Stair case Light pointHigher End 221 Wiring with 2Rx1.5 sq.mm. (22/0.3) PVC insulated Single core unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 1no. 6A one way module switch and 1no. 6A 3/2 Pin module socket with module front plate with continuous earth wire connection of 1 run of 1.5 Sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Pipe 5A Plug Point ( 8 Points / Coil ) 222 Wiring with 2Rx4sq.mm PVC insulated Single core unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module Plastic switch box in flush with wall with 1no. 16A one way module switch and 1no. 16A 3/2 Pin module socket with module front plate with continuous earth wire connection of 4.0Sq.mm copper wire and making good of the concealed portion with painting ofsuitable colourfor Concealed PVC Pipe 15A Power Plug Point ( 8 Points / Coil ) 223 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 224 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 225 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 226 Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug in flush with wall with earthconnection (For AC Plug) 227 LED LIGHTINGS 228 Supply, fixing, testing & commissioning of 15W concealed mountingLEDCylindrical luminairewithDie-Cast Aluminium sheethousing withopal high transmission diffuserfixedinseparateDie-Cast Aluminiumsheet frame with operating voltage range (90 - 265V AC). LED driver efficiency should be greater than 83% with CRI greater than 80 and withcolourtemperature4000Krange.LEDhaving50,000 burning hours with minimum 80% lumen maintenance and power factor 0.90 with THD less than 20% & Surge protection 2.5kV. Systemconsumptionshouldbe15WLED fixture with lumen package of 2250 lumens. The luminaire shall be IP40 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Note: All Indoor luminaire shall have NABL certificate on Resistance to Flame & Ignition as per IS 10322 part-1 :2014. Make: K-Lite or Equivalent. 229 Supply, fixing, testing & commissioning of 15W Surface mountedLEDCylindrical luminairewithDie-Cast Aluminium sheethousing with Translucent Polystyrene diffuser fixed in separateDie-Cast Aluminium sheet frame with operating voltage range (90 - 265V AC). LED driver efficiency should be greater than 85% with CRI greater than 80 andwithcolourtemperature4000Krange.LEDhaving54,000 burning hours with minimum 85% lumen maintenance and power factor more than 0.90 with THD less than 10% & 2.5kV surge protection. System consumption should be 15W LED fixture with lumen package of 2000 lumens. The luminaire shall be IP40 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Note: All Indoor luminaire shall have NABL certificate on Resistance to Flame & Ignition as per IS 10322 part-1 :2014. Make: K-Lite or Equivalent. 230 Supply, fixing, testing & commissioning of 18W Surface mountedLEDCylindrical luminairewithDie-Cast Aluminium sheethousing with Translucent Polystyrene diffuser fixed in separateDie-Cast Aluminium sheet frame with operating voltage range (90 - 265V AC). LED driver efficiency should be greater than 85% with CRI greater than 80 andwithcolourtemperature4000Krange.LEDhaving54,000 burning hours with minimum 85% lumen maintenance and power factor more than 0.90 with THD less than 10% & 2.5kV surge protection. System consumption should be 18W LED fixture with lumen package of 3300 lumens. The luminaire shall be IP40 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Note: All Indoor luminaire shall have NABL certificate on Resistance to Flame & Ignition as per IS 10322 part-1 :2014. Make: K-Lite or Equivalent. 231 Supply, fixing, testing & commissioning of 12W surface mountingLEDCylindrical downlight luminairewithDie-Cast Aluminiumsheethousing withClear PolycarbonatediffuserfixedinseparateDie-Cast Aluminiumsheet frame with operating voltage range (100 - 265V AC). LED driver efficiency should be greater than 85% with CRI greater than 80 andwithcolourtemperature4000Krange.LEDhaving50,000 burning hours with minimum 85% lumen maintenance and power factor 0.90 with THD less than 20% & Surge protection 3kV.Systemconsumptionshouldbe12WLED fixture with lumen package of 1680 lumens. The luminaire shall be IP20 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Note: All Indoor luminaire shall have NABL certificate on Resistance to Flame & Ignition as per IS 10322 part-1 :2014. Make: Crompton, K-Lite, Ace or Equivalent. 232 Supply, fixing testing and commisioning of 20W Cloud shape designer pendant light in Warm white temp. as per Architects design given in Computer Section with operating voltage range (120 - 270V AC). LED driver efficiency should be greater than 85% with CRI greater than 80 andwithcolourtemperature3000Krange.LEDhaving50,000 burning hours with minimum 70% lumen maintenance and power factor 0.90 with THD less than 10% & UGR < 19 complaince to LG7guidelines. The luminaire shall be wired with PVC unsheathed copper leads from terminal to the fitting.(140 lm/W) Make: Crompton, Philips, Bajaj or Equivalent. 233 Supply, fixing, testing & commissioning of60W Linear Light [1.2 [12W]+1.2[12W]+6.1 [6W]+6.1 [6W]] combination Customized pre fixed Recatngular Linear light with Wooden JointsSuspended mountedLED luminairewith Extruded Aluminium body with Die-Cast Endcaps withpolycarbonate diffuser. LED driver efficiency should be greater than 85% with CRI greater than 80 andwithcolourtemperature4000Krange. LEDmore than 90% lumen maintenance and power factor more than 0.90 with THD less than 10%, Surge protection 3kV and UGR < 12. The luminaire shall be IP40 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Note: All Indoor luminaire shall have NABL certificate on Resistance to Flame & Ignition as per IS 10322 part-1 :2014. Make: K-Lite or Equivalent. 234 Supply, fixing, testing & commissioning of 9W In-ground LED luminaire with Die-Cast Aluminium housing with toughened clear diffuser and 316 grade Stainless steel front ring with operating voltage range (100 - 277V AC). LED driver efficiency should be greater than 85% with CRI greater than equal to 80 andwithcolourtemperature3000Krange.LEDhavingmore than 60,000 burning hours with minimum 70% lumen maintenance and power factor more than equal to 0.90 with THD less than 10% & Surge protection 2.5kV.Systemconsumptionshouldbe9WLED fixture with lumen package of 1350 lumens. The luminaire shall be IP67 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Note: Product should have Narrow beam, Moisture arrestor, IP 68 Connector for on site connections.Luminaire should have Anti Glare VisorHoneycomb assembly. Make: K-Lite or Equivalent. 235 Supply, fixing, testing & commissioning of 8W In-ground LED luminaire with Die-Cast Aluminium housing with clear toughened glass diffuser and 316 grade Stainless steel front ring with operating voltage range (150 - 270V AC). LED CRI greater than equal to 80 andwithcolourtemperature2700Krange.LEDhavingmore than 60,000 burning hours. The luminaire shall be IP67 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Note: Product should have Narrow beam, Moisture arrestor, IP 68 Connector for on site connections.Luminaire should have Anti Glare VisorHoneycomb assembly. Make: K-Lite or Equivalent. 236 Supply, fixing, testing & commissioning of Nebula Midi 12W Inground spike / Die-Cast Aluminium bracket mounted LEDcylindrical luminairewithDie-Cast Aluminiumalloy housing withclear toughened glass diffuser with operating voltage range (100 - 300V AC). LED driver efficiency should be greater than 80% with CRI greater than equal to 80 and with colour temperature 3000Krange. LED having power factor more than 0.95 with THD less than 10% & Surge protection 4kV.The luminaire shall be IP66 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Note: Product should have Moisture arrestor and IP 68 Connector for on site connections.Luminaire should have Anti Glare Visor + Honeycomb assembly. Make: K-Lite or Equivalent. 237 Supply, fixing, testing & commissioning of 6W / 2x6W Wall mountedLEDwall luminairewith Extruded & Die-Cast Aluminium body with clear toughened glass diffuser and Mirror finish pure Aluminium reflector. Operating voltage range (100 - 300V AC). LED driver efficiency should be greater than 80% with CRI greater than 80 andwithcolourtemperature3000Krange.LEDhaving power factor more than equal to 0.95 with THD less than 15% & Surge protection 4kV. The luminaire shall be IP65 rated and wired with PVC unsheathed copper leads from terminal to the fitting. Make: K-Lite or Equivalent. 238 Supply and fixing of 1200mm(48) sweep A ceiling fan - Havells make - complete with stepped electronic 300W regulator with 600mm down rod with fan clamp with side plates and cross arm of size 450mm(18) 239 Supply and fixing of 450mm (18) Wall mounting 5 star rated complete (Higher end) with necessary accessories and hardwares as required. 240 Supply and fixing of 300mm (12) sweep AC exhaust fan complete without provision of hole in the wall 241 Supply and fixing of louvers shutters arrangements for 300mm (12) sweep AC exhaust fan 242 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm withcopperearthplateofsize125mmx50mmx6mmwithnecessaryfunnelingarrangementswithnecessary masonry work and with 38mm RCC cover slab for the brick masonry 243 Supply and erection of Copper plate earthing station with GI pipe, 600x600x3mm thick copper plate, salt, charcoal, etc., including civil works, heavy duty CI Cover, etc., as per IS 3043 standards 244 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 245 Supply and Run of1 of No.8 SWG copper wire for earth connection 246 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 247 Supply and fixing of 10A 400V, 50 Hz 3 phase 4 wire watt hour meter on suitable TW box with earth connection 248 The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates,materials.The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fasteners, welding, anchor bolts, nuts etc.The rack shall have suitable cable clamping arrangements etc.Cable Tray /ladder should be powder quoted as match with ceiling colour as per PWD requirements.The rate shall inclusive of necessary Wedge anchors threaded rods,nuts & bolts, making clamp for rcc roof fix/ perlin/Truss, cable tray clamps etc, (8 mm threaded rod supports shall be providedat not more than 2 mtr center to center and as per site requirement ) 249 Perforated type Supply and fixing ofGI Hot Dip / Powder Coated 16 SWG Cable Tray with 300 mm width and 50mm height 250 Perforated type Supply and fixing ofGI Hot Dip / Powder Coated 16 SWG Cable Tray with 150 mm width and 50mm height 251 Supplying and fabricating of MS structural steel supports for various applications using U channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above. 252 Supply and fixing ofRaceways Metal / GI with 150mm widthx 38mm heightwith Suitable Fixing bracket and Siutable Coupler Jiont with Connected all accessories complete work. 253 Construction of inspection chambers of following sizes 60 x 60 x 60cm with earth work excavation for foundation with 23cm thick brick jelly cement concrete bed in C.M.1:4:10 using 40mm Brick jelly for foundation, brick work in C.M.1:6 for chambers, plastering with C.M.1:3 12mm thick, benching, channelling, 75mm thick RCC loose slab covering in C.M.1:2:4 mix using 20mm blue granite jelly including necessary reinforcement, etc., complete . (GCC -2023-24, SCH No:718, P.No-45) 254 Supply,fixing and laying of Heavy duty PVC pipes complete buried in floor with joints and other accessories as required.110 mm dia, 2mm thick 255 Split Type AC UnitSupply, Installation, Testing and Commisioning of Wall mounted Split type Inverter 2.2 TR Air Conditioning Unit with supply and installation of necessary accessories including necessary length of copper pipes, suitable type double boost voltage stabilizer, pvc drain pipes, also includes necessary opening in the walls (if necessary) for the drain pipe routing, outdoor unit stand and all other required accessories for the 2.2TR split type AC unit. The quoted rate should be inclusive of materials, labour, wages, fixtures, transportation, installation, wasteages, Octroi, machinery, temporary works such as scaffolding, cleaning, overheads, profit, statutory expenses, incidental charges and all related expenses to complete the work. 256 5KVA UPSSupply, erection, testing and commissioning of the following rating of UPS Systems for emergency lightings. Supply of Micro Processor Controlled 5 KVA UPS andinput supply of 430 Volts ± 15%, 3 Phase, 50 Hz ± 5%and an out put of 230 Volts ±1%, 1 Phase 50 ± 0.01 Hzconsisting ofRectifier, Out put Isolation Transformer, Battery Circuit Breaker, Static and Manual Bypass Switches and all others accessories required as per detailed specification .The system should be suitable for independent mode of operation.Supply of Sealed Maintenance Free Batteries to support 5 KVA for 6 hrs complete with intercell connectors, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries as per specification.Installation,Testing and Commissioning of complete1 nos 5 KVA UPS system in Independent mode of operation with the battery bank including inter connection of UPS and battery banks with adequate size of copper cable, lugs etc. complete as required. 257 Supply and erection of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS (5 NOS) 258 Supply of First Aid Box complete with all First Aid Medicines 259 Supply and fixing of Shock Treatment chart with Glass frame 260 Supply and fixing of4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle 261 Supply and fixing of Fire Extinguishers Co2, 4.5Kg confirming to TAC norms 262 Supply and fixing of Danger Boards (415Volts & 230Volts) 263 XEROX MACHINE: Supply, installation, testing and commissioning of A3 Xerox 5855 Photocopier machine, Multi-function, Windows 11, laser printing with multiple features like Print, Scan, Copy, 2-sided ouput, Network connectivity, print speed upto 55 pages per minute, print resolution upto 4800x1200 dpi and paper capacity 46000 sheets (standard) / 8700 sheets (max with optional feeders) 264 DESKTOP PC: Supply, installation, testing and commissioning of Dell Inspiron 27 All-in-One Desktop PC of following specifications:1.Processor: Intel Core7 150U (12MB cache, 10 cores, 12 threads, upto 5.4 GHz Turbo)2. Operating System: Windows 11 Home Single Language, English3. Graphics Card: NVIDIA GeForce MX570A with 2GB GDDR6 graphics memory4. Monitor: 27, FHD 1920x1080, 60Hz, WVA, Touch, InfinityEdge, Narrow Border5. Memory: 16GB: 2 x 8GB, DDR4, 3200 MT/s6. Storage: 1TB M.2 PCle NVMe Solid State Drive7. Color: Pearl White Cover + Molded Speaker Grill (for Touch LCD)8. Microsoft Office: Microsoft Office Home and Student 20219. Security Software:McAfee LiveSafe 1-year (5-device)10. Keyboard: Dell Pro Wireless Keyboard and Mouse - Dell KM5221W White11. Wireless: Intel Wi-Fi 6E AX211, 2x2, 802.11ax, Bluetooth wireless card12. Power: 90W AC adapter, 4.5mm barrel 130W AC adapter 4.5mm barrel 265 PRINTER: Supply, installation, testing and commissioning of HP Smart Tank 790 WiFi All-in-One Printer Duplexer with ADF and Magic Touch Panel Inkjet Colour printer, print speed 11-20 sheets with multiple features like print, scan, copy, fax, multi-port connectivity (Hi-speed USB 2.0, Wifi, Bluetooth LE , 1 USB Host, LAN) , 2.4/5G dual band Wi-Fi, Wi-Fi Direct, mobile printing capability, etc 266 METAL SIGNAGE BOARDS: Supply and fixing of metal signages for the following:1. Mudhalvar Padaipagam text in Tamil of size 20 x 15with backlit LED placed over the base, fabricated using stainless steel sheet of minimum 16G thickness brush finish of required size and colour as required. 267 LOGO SIGNAGE BOARDS: Supply and fixing of acrylic signages for the following:1. Mudhalvar Padaipagam logo of size 2 x 22. CMDA logo of size 3 x 463. Directorate of Public Libraries logo of size 6 diawith backlit LED placed over the sun board base, SIDE EDGES(4): 5mm transparent white acrylic sheet with laser cut & 4inches manual raising all around with details. ACRYLIC SHEETS & ITS TECHNICAL PARAMETERS:Front: a. 5mm Imported (Mitsubishi/equivalent) acrylic cutting on laser cutting machine.b. Flexi bond make 25mm Sun board for the back of the logo. 268 CCTV SYSTEM 269 Supply, Installation, Testing and commissioning of 32 channel 2 SATA NVR, with 8TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency,Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony. 270 Supply of 4MP, Internet Protocol fixed BULLET CAMERA/DOME CAMERA (INDOOR & OUTDOOR)with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand. (Make: Dahua/Panasonic) 271 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 4K monitor b) IPS pannel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 272 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pairvi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 273 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 274 Supply and fixing of POE 24 port switch with two uplink port, 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 275 Supply and fixing of POE 8 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 276 Supply and Fixing of Rack with Accessories -Higher end12u Rack with fan extra for the above rack. (speaker/data/cctv) 277 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2 Hours back up andbattery stand. 278 Supply, Erection of 6mLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges. 279 Supply and Run of 3C X 2.5 sqmm insulated multistrandad flexible copper Trailing Flat/round cable of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with painting of suitable colour. 280 Supply, installation, testing, and commissioning of broadband WiFi connection with the following specifications: Networking Interface: (1) GbE RJ45 PortPower Method: PoE+, Pasive poE(48V)Max TX power: 5.0 GHzAntenna gain: 5.0 GHzMounting: Wall or Ceiling MountingWireless security: WPA-PSK, WPA-Enterprises (WPA/WPA2/WPA3)VLAN: 802.1QConcurrent Clients: 300+5G connectivity,300mbps speed, unlimited monthly data plan, 5G compatible router with wifi boosters provided at required areas. 281 PA SYSTEM 282 Supply, Installation,Testing & commisioning of 15W Wall Speaker 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make:AhujaAMH402T/Bosch or its equivalent) 283 Supply, Installation,Testing & commisioning of 480 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000/Bosch or its equivalent) 284 Supply, run, testing and commissioning of2Core x 1.5sq sqmm PVC insulated UnArmoured Speaker Cable in suitable 25mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 285 Supply & Installation of custom built M.S Powder coated wall mounting Audio rack (42U Rack) with Lock & key for housing of Amplifier & player/Recorder conforms to EIA-310,IEC-60297 and able to withstand the load of 40kg with welded construction made up of CRCA steel with suitable height, width and depth.
Contract Date: May 28, 2025 Contract Value : 4.26 Crore
Local Bodies No of Bidders 3
47.
Defence #7398490 AOC
Tender For Provision Of Otm Accommodation For Fwtf At Afs Yelahanka; 1 BOQ Dated MAR 2025 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XII are prepriced by MES under Ser No. 1 to 12. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Building or Works” as listed in Schedule ‘A’Part–I 4 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II 5 Lumpsum price worked out by the contractor for “Internal Electric Supply as listed in Schedule ‘A’Part–III 6 Lumpsum price worked out by the contractor for “Road / Path / Culvert as listed in Schedule ‘A’ Part - IV . 7 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule ‘A’ Part - V . 8 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI. 9 Lumpsum price worked out by the contractor for “Rain Water Harvesting” as listed in Schedule ‘A’ Part – VII. 10 Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – VIII 11 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – IX 12 Lumpsum price worked out by the contractor for “Cooling Appliances” as listed in Schedule ‘A’ Part – X 13 Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part – XI 14 Lumpsum price worked out by the contractor for “Demolition of Building (B/R & E/M)” as listed in Schedule ‘A’ Part – XII 15 Sch A Part - XIII : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLYSupply and fix 15 mm bore two way bib tap and Health faucet cast copper alloy chromium plated fancy type, screwed down, screwed for galvanised iron pipe, complete all as specified and as directed. 16 INTERNAL ELECTRIC SUPPLY S & F modular type 6 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 17 S & F modular type 6 A 2-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 18 S & F modular type 16 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 19 S & F modular type 2/3 pin combined shuttered type 6 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 20 S & F modular type 2/3 pin combined shuttered type 16 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 21 S & F modular type 20 A 1P MCB with socket, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 22 S & F 20 W surface / wall mountedLED batten capable of delivering 2100 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge. 23 S & F 10W 2 Feet LED Batten capable delivering 1000 lumen having luminous efficacy of > 100 lm/W, starting time < 0.5 s, CRI > 80, CCT 5400K, PF >0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed by the engineer-in-charge. 24 S & F 35 W street/Security light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 2600 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high efficiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete in all respect as specified and directed by engineer-in-charge. 25 S & F 10W Bulkhead LED Lightinput voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed by the engineer-in-charge. 26 S & F modular type 1 module RJ-11 telephone socket with shutter complete all as specified and directed by the engineer in charge 27 S & F modular type 1 module co-axial type TV socket all as specified and directed by the engineer in charge 28 S & F 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed by the engineer-in-charge. 29 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental typeMLTP (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge. 30 Make: Schneider, Siemens, ABBThe MLTP shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of AL busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i] 320A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i]200A, 230 V, Ics = 100% Icu = 10 kA, 50 Hz 4P MCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [ii]125A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[iii]63A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 02 Nos. [v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 5 Nos.[vi] LED phase indicators (Red, Yellow, Blue)- 5 Set 31 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-1 (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge. 32 Make: Schneider, Siemens, ABBThe panel shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of AL busbar of rated capacity 240A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]200A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i]63A, 415 V, Ics = 100% Icu = 10 kA, 50 Hz 4P MCB, conforming to IEC 60947-2,front indication LEDs (ready, overload and pre-alarm & overload)- 07 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 07 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 07 Set 33 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type PDB-2 panel of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge. 34 The Panel shall comprise of the following:[A] BUSBAR CHAMBER[i] 01 Set (3L + N) of copper busbar of rated capacity 160 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i]125A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 Nos.[ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING.[i]63A, 415 V, Ics = 100% Icu = 10 kA, 50 Hz 4P MCB, conforming to IEC 60947-2,front indication LEDs (ready, overload and pre-alarm & overload)- 07 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 07 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 07 Set 35 EXTERNAL WATER SUPPLYCutting existing DI, 150mm borewater mains and inserting Tee 150mm x 150mm x 50mm for taking branch connection including fittings and joints complete all as specified and directed. 36 Construction of valve chamber with inner clear dimension 600 x 600 x 600mm suitable for 150mm sluice Valves with PCC (1:4:8) 150mm thick type D2 for foundation, Brick masonry 230mm wall in CM (1:4), PCC (1:2:4) 75mm type B1 for coping, rendering in CM (1:4) 15mm thick including provision of 3mm thick MS sheet cover and 25 x 25 x 3mm angle frame embedded in coping with two coats of synthetic enamel paint over a coat of redoxide primer with locking arrangements including necessary earth work complete all as specified and directed. 37 Cutting the existing DI pipe of size 100 mm dia, inserting tee of size 100 x 100 x 32 mm for taking branch connection including necessary jointing materials, joiningtesting etcthreading, including earth work, returning, refilling etc complete all as specified and as directed. 38 Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 7.4 (PN-16) size outer dia 32mm and PP-R plain fittings in trenches/walls/ceilings or laying in floors,including all fittings complete all as specified and directed. 39 Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 7.4 (PN-16) size outer dia 20mm and PP-R plain fittings in trenches/walls/ceilings or laying in floors,including all fittings complete all as specified and directed. 40 EXTERNAL ELECTRIC SUPPLYMaterial and labour for dismantling, shifting and re-installation with complete incomer/outgoing connections, Step down transformer of 11KV/433volts, 200 KVA capacity, from existinglocation including leveling of old foundation complete all as specified and directed by Engr-in-Charge.Note : (i) Rate deemed to be included labour & JCB/crane charges for shifting and connecting up incomer HT and outgoing LTconnections.(ii) Cable jointing kit will be measured and paid separately under relevant items. 41 Supply, install, testing & commissioning of outdoor type step down transformer 11000/433 Volts (at no load), AC, 3 phase, 50 c/s, capacity 500KVA, core type copper wound, oil immersed, naturally cooled, oil natural, air natural, (ONAN) with external cooling tubes/fins delta connected on primary side(HV) and star connected on LT side(LV) in accordance with vector symbol DYN-11(Vector group) with off load type changeover switch with accuracy(+/-)7.5% complete with steps of 2.5% and mounted on existing platform/structure, connecting up with the existing earthing strips,etc.complete.The maximum temperature should not exceed 45° c in oil and 55°c in HV/LV coil winding when measured by resistance method after continuous full run on an ambient temperature of 50°c.The transformer shall be IS 2026 marked and comprise of the following:- 42 (a) cable end box on HV side suitable for 11 KV complete with bushing, copper rods, nuts and washers.(b)One cable box on LV side(secondary side) consisting 03 nos porcelain bushing suitable for 433Volts complete with bushing, copper rods, nuts and washers along with neutral bushings(c)Oil conservator with filter type drain valve and oil level gauge(d)De-hydration breather transparent body with first fill of dehydrating agent(Silica gel)(e)Explosive vent(f)Thermometer pocket on tank cover(g) One no 100mm dia, dial type thermometer,vapour pressure type having range 0° to 120°c with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing of neutral and body.(i) Rating plate and terminal marking plate(j) Oil level gauge(k)Oil drain filter valve (l)Lifting lugs(m) Oil filling holes with cap/plug with connecting plate complete(n) Air release valve plug(o)Four plain solid cast steel detachable rollers(p)First filling of new and unused transformer oil IS-335/93(fourth division) marked, filtered and tested upto 50 KV dielectric strength at 2.5 mm air gap between testing electrodes complete all as specified and as directed by Engr-in-Charge.Note: Certification of electric strength shall be submitted by the contractor after filling the oil. 43 Returning and filling of trenches in two parts(i) using riddled soil obtained fromexcavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and(ii)refilling the trench of remaining depthwith normal excavated soil all as specified and directed.Note :- (i) Excavatedsoil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. 44 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all specified and directed by Engr-in-Charge. 45 Supply and fix terminal box made out of SMC with hinged door and locking arrangements of size 200x140x95mm Including Backlite 4 way connector, M S Clamps suitable for pole, PCC/MS/GI/rail etc. with bolt, nut and washer, electrical connections including MCB SP 6-32 Amps complete all as specified and as directed by Engr-in-Charge. 46 M&L for laying 3 core x2.5 sqmm copper conductor, 1100 volt grade, PVC insulated, sheathed for street light fittings from junction box to street light fittings complete all as specified and as directed. 47 Fabricate, supply, install testing and commissioning ofLT panel indoor type made out of ms sheet 2mm thick with locking arrangement and painting, Bus bar AL capacity 600Amps including PCC platform made out of 1:2:4 type B1 and pedestal of 30cm height from ground level with suitable nuts, bolts and washers for mounting of the panel, detachable plate shall be provided at the bottom of thepanel with necessary holes suitable for termination of various sizes of cables with glands and painting with two coats of super enamel paint over the coat of metal primer all as specified and directed and panel shall be suitable to accommodate including supply and fixing of following switchgears (Inside proposed Bldg) :-(a) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA-1 No(incomer). (b) 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 35 KA-1No. (c) 4 Pole MCCB 63 Amp, 50 Hz, 415V with rupturing capacity 25 KA-03 No. (d) MCB SP 6A , 230 Volts, 50 HZ -1 Nos. (e) Timer switch 250 volts, 20Amps-01 No. (f) Digital Volt meter (0-500 V)-01 No. (g)Digital Ammeter-01 No. (h) CTs 400/5- set of 3Nos. (j) Volt meter selector switch-1 No. (k) Ammeter selector switch- 1 No. (l) LED type Indication lamps (RYB)-01 Set of three. 48 Fabricate, supply ,install testing and commissioning ofLT panel outdoor type made out of ms sheet 3mm thick with locking arrangement and painting, Bus bar AL capacity 1200Amps including PCC platform made out of 1:2:4 type B1 and pedestal of 30cm height from ground level with suitable nuts, bolts and washers for mounting of the panel, detachable plate shall be provided at the bottom of thepanel with necessary holes suitable for termination of various sizes of cables with glands and painting with two coats of super enamel paint over the coat of metal primer all as specified and directed and panel shall be suitable to accommodate including supply and fixing of following switchgears (Inside proposed Bldg) :-(a) 4 Pole ACB 800 Amp, 50 Hz, 415 V with rupturing capacity 36 KA-1 No(incomer). (b) 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 35 KA-2No. (c) Digital Volt meter (0-500 V)-01 No. (g)Digital Ammeter-01 No. (h) CTs 400/5- set of 3Nos. (j) Volt meter selector switch-1 No. (k) Ammeter selector switch- 1 No. (l) LED type Indication lamps (RYB)-01 Set of three. 49 M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick buried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to32 x 6mm galvanized MS Strip as earth lead upto a length of 7.5 metre long by means of bolts, nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed by Engr-in-Charge. (External Electric Supply - 8 + DG Set - 6) 50 DG SETSupply install testing and commissioning of factory assembled sound proof diesel engine driven generating set, with standard control panel, capable of delivering not less than 320 KVA (256 KW) at NTP conditions including acoustic enclosure as per latest CPCB norms IV+, complete with AMF control panel, common base frame, AVMs, 24 volt starting batteries of suitable rating as per manufacturers recommendation with leads and terminals, charging alternator and control accessories all prewired, residential type silencer and exhaust piping of suitable size (minimum 106 mm dia) duly insulated and aluminium sheet claded and extended upto outside of power house, hand fuel pump with 5.0m long flexible hose, fuel tank of not less than 500 litres capacity & DEF tank not less than 40 litres capacity, fuel line connections, including retrofit emission control device etc with all accessories complete with the following components:-Make of DGset assembled with sound proof canopy - Cummins India / Kirloskar (KOEL Green) / Jackson / Sudhir / Greaves Cotton 51 [a] Engine - 4 stroke multi cylinder, turbo charged, compression ignition, water cooled with standard integral set mounted radiator, continuous rated generator duty engine with CPCB Norms-IV+ approved and having Electronic governing of appropriate class conforming to IS 8528 Part-V, engine capcity capable to generate 320KVA at 0.8 PF at 1500 RPM at NTP with 10% over load capacity for 1 hour once every 12 hours complete with all safety accessories suitable for above DG set, directly coupled with alternator and the engine conforming to BS 5514 / IS10002:1981 complete including first fill of lub oil and coolant all as specified. Make: Cummins / KOEL (Kirloskar) / Greaves Cotton / Cater pillar / Ashok Leyland[b] Alternator:-Self regulated, self exited brushless copper wound alternator, 415 V, 3 phase, 4 wire, 50 HZ, capable to generate200 KVA/160 KW at PF - 0.8 lagging, 1500 RPM, with voltage variation plus or minus 10% of rated voltage from no-load to full-load, foot mounted, screen protected drip proof type with class H insulation, with IP-23 ingress protection, ball/roller bearings at both ends of the alternator shaft, with AVR as recommended by the manufacturer, suitable for direct coupling with engine and conforming to BS-5000/IS-4772 / IEC 60034-1 all as specified. Make: Stamford /Kirloskar (KOEL green) / Crompton Greaves[c]Acoustic Enclosure - Prefabricated factory built, free standing, floor mounting type acoustic enclosure of modular construction suitable for accommodating the 320 KVA Engine Alternator set with integrated fuel tankand should be fabricated with specially formed CRCA sheet metal of thickness not less than 1.60mm for enclosure and 3.0mm for base frame with adequate stiffeners for strength and roof panels designed with slopes to prevent rainwater stagnation and sound proofing with insulation material of PU foam of appropriate thickness and density for sound abruption as per standard design of manufacture to achieve suitable noise attenuation level of less than 75 dBA @ 1 Mtr at 75% load and hinged doors with locking arrangement including emergency stop button at outside. The enclosure shall conform to the latest environment Protection Act 1986 (29 of 1986) of Ministry of Environment and Forest Notification dated 17th May 2002 and 12th July 2004 and as amended up-to-date. Valid CPCB IV+ certificate of authorized agency such as ARAI of Pune, NPL New Delhi, NSTL Vishakhapatnam, FCRI Palghat and NAL Bangalore shall be submitted. 52 [d] AMF Panel - AMF panel with hinged doors with locking arrangement fabricated from 2.0 mm thick CRCA sheet, in dooor type incl all accessories like control wiring and protection devices with 2 Nos 500 A 4 Pole, 36 KA MCCB with Thermal magnetic release, 2 Nos 500 Amps AC 3 duty 4 pole power contactors for mains supply and DG supply with inter connecting aluminium bus bars, electronic earth fault protection relay, micro processor based AMF controller having facility to start the DG set and restore power supply within 15 seconds of power failure with communication port, frequency meter, 3 Phase electronic type AC KWH meter with suitable 3 Nos CTs 500/5A, electronic earth fault protection relay, AC volt and Ampere meter, HRC fuses, push buttons for start / stop / reset, LED type indicating lamps as required, SMPS based battery charger with automatic float & boost changeover facility, control circuit fuses/MCBs, reverse power relay, alarm for high water/ lub oil temp and low lub oil pressure and any other control devices/measuring instruments as recommended/required in accordance with latest engineering practices andspecifications as recommended by OEM and asdirected by Engr in Charge.AMF Controller Make :-As per OEM) 53 COOLING APPLIANCESSupply, fixing, jointing and testing copper tubing with nominal diameter1/4 inch of suitable thickness for liquid line to connect with out door unit complete all as specified and directed by Engr-in-Charge. 54 Supply, fixing jointing and testing copper tubing with nominal dia meter3/8 inch of suitable thickness including expanded polythene foam insulation for external insulation of suction line for connecting with outdoor condensing unitcomplete all as specified and directed by Engr-in-Charge. 55 Material and Labour for fabrication of base stand from MS angle iron of size 50mmx50mm, 6mm thick including necessary nuts, bolts & washers for mounting of outdoor unit of 1.5/2 TR capacity Split AC complete all as specified and directed by Engr-in-Charge. 56 Supply and fix PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed by Engr-in-Charge. 57 LIGHTNING PROTECTIONMaterial and labour for corrosion resistant earthing system completecomprising ofthe following items:-(a) 17.2 mm dia, 3mtr length,Low carbon steel earth electrodewith minimum 250 micron copper bonding certified by CPRI. (Copy of CPRI certificate to be submitted.(Dia of the rod &control number allotted to the manufacturer should be embossed on the rod and certificate from the same manufacturer shall be submitted along with the material). (b) 25 kgs of earth enhancement material, environment friendlybackfill compound. (c) Suitable clamp, 17.2minimum outer dia SS clamp both side. (d) Rust & weather proof heavy duty FRP earth pit chamber with dimensions 254 mm dia (top), 330 mm dia (bottom) & 260 mm (height). (e) Exothermic welded joints. (f) Provision of one copper bus bar near tapping point for connection complete all as specified and directed by Engr-in-Charge. Make:CAPE/JEF/ABB Fuse. 58 SPECIAL ITEMS OF WORKSupply and fix LED spot lights (focus light), 10 Watt, warm white colour, 180 degree adjustable wall/ceiling mountable, white body complete all specified and directed by Engr-in-Charge. 59 Supply and fix 32mm dia PVC conduit complete all specified and directed by Engr-in-Charge. 60 Supply and fix industrial grade socket single pole and neutral enclosure with a two pin and earth plug socket including one SPN MCB of 16 Amps, C Curve, 10 KA rupturing capacity complete all specified and directed by Engr-in-Charge. 61 Supply and fix SPD 320 Volts, AC complete all specified and directed by Engr-in-Charge. 62 Supply and fix Electric Chimney of size 90 CM, Air suction capacity 1420 Nm3/Hr, Filterless and automatic clean technology, Air pipe of size 160 mm dia complete all specified and directed by Engr-in-Charge. 63 DEMOLITION OF BUILDING (B/R & E/M)Dismantling and taking down old PVC Sintex Tank of capacity 10000 Ltrs complete all as specified and as directed. 64 Dismantling and taking down ofold unserviceable MCB DB 8 way including MCBs of any type/size complete all as specified and as directec. 65 Taking down old unserviceable service wire 2 core 10 Sqmm complete all as specified and as directed.
Contract Date: May 27, 2025 Contract Value : 7.68 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
48.
Defence #7347836 AOC
Tender For Provision Of Toilets In Firing Rg At 3 Mtr Margao Goa.; 1 Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for foundation etc.and getting out in soft disintegrated rock complete all as specified and directed. 2 Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation laying of pipe line etc and getting out in hard/dense soil complete all as specified and as directed. 3 Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and gettingout complete all as specified and as directed. 4 Returning filling in including spreading levelling watering and well ramming in layer not exceeding 25cm complete all as specified and directed. 5 Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting pointcomplete all as specified and directed. 6 Material and Labour for PCC 1:4:8 (type D2) using 40mm graded aggregate as in foundation complete all as specified and directed. 7 Material and Labour For Brickwork with fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in C M 1:4 complete all as specified and directed. 8 Material and Labour for brick work with fly ash bricks straight or covered on plan to any radius in half brickwalls in built in CM 1:4 complete all as specified and directed. 9 Material and Labour for PCC 1:2:4 type B1 (20 mm gradedaggregate) Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto1.5m clear span,cills,steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering,slightly rounded or chamfered angles and throating complete all as specified and directed. 10 Material and Labour rendering 15 mm thickon stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing in CM 1:6without using extra cement complete all as specified and directed. 11 Material and Labour rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing in CM 1:4 without using extra cement with using water proofing compound complete all as specified and directed.Note :- Water proofing compound will be measered separately. 12 Supply only integral waterproofing compound complete all as specified and directed. 13 Material and Labour for two coat of oil bound distemper over 3 mm thick wall care puttyon plastered surfaces ofwalls including prepartion of new/old surfaces complete all as specified and directed. 14 Material and Labour for preparation of new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489-2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over 3mm wall care putty on new surface completeall as specified and directed. 15 Material and Labour Formwork to soffits of suspended slabs such as roof slabs, floor slabs etc. not exceeding 200mm thick rough finished surfaces of finished concrete complete all as specified and directed. 16 Material and labour for RCC 1:2:4 typeB-I using 20 mm graded stone aggregate as in slabs, supported on walls, landings, balconies,shelves and the like complete all as specified and directed. 17 Supply and fix TMT bars 10 mm dia and over, cut to length, bend to shape including cranking, hooping etc. and binding with ms wire (annealed) not less than 0.9 mm dia complete all as specified and directed. 18 All as per above Item No but for6 mm to 8 mm dia. 19 Material and Labour Moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering complete all as specified and directed. 20 Material and Labour Hard core of guage not exceeding 63 mm , deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface of broken stone or boulders complete all as specified and directed. 21 Material and Labour 75mm thick PCC 1:4:8 type D-2(using 40 mm graded aggregate) as in sub base under flooring complete all as specified and directed. 22 Material and Labour for 50mm thick PCC 1:3:6 type C-1 as in plinth protection complete all as specified and directed. 23 Material and Labour coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cementslurry and pointed in white or coloured cement to match including 20mm thick screed bed in CM 1:6 complete all as specified and directed. 24 Material and Labour glazed ceramic coloured designer pattern tiles 450mmx 300mmx7mm thick on vertical surface such as skirt, Dado etc set and jointed in white colour cement including 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 complete all as specified and directed. 25 Material and Labour cement concrete type B1 1:2:4 using 20mm graded stone aggregate 25mm thick as in flooring etc. complete all as specified and directed. 26 Material and Labour Chequered cement concrete tiles (200x200x25mm) thick with grey cement and no pigment, set jointed & pointed in neat cement slurry in floors over 15 mm thick screed bed of 1:6 cement mortar complete all as specified and directed. 27 Supply and fix solid PVC door frames of size 50mm x 47 mm made out of 5 mm thick plain/printed coloured PVC sheet reinforced with MS square tube complete all as specified and directed. 28 Factory made solid PVC moulded Door shutter, 28 to 30 mm thick (stiles), with 2,4, or 6 raised panel design with 2mm thick moulded coloured PVC sheet on front face & 2mm plane colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with particle board core. 29 Supply and fix 125 mm aluminium handles,cast type anodised complete all as specified and directed. 30 Supply and fix 100mm butt hinges for windows medium weight,cold rolled mild steel and fixed complete all as specified and directed. 31 Supply and fixAluminium anodised barrel tower bolts150mm for door of extruded section and fixed complete all as specified and directed. 32 Supply and fix for Power coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 33 Supply and fix Power coated aluminium window and ventilator shutters fixed, openable or sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. 34 Supply and fix Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples as repair complete all as specified and directed. 35 Supply and fix Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automaticshing cistern with brackets, flush pipe, grating and Union for discharge pipe (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. 36 Supply and fix 4 mm thick plain sheet glass ordinary quality fix with bead in squaresnot exceeding 0.5 Sqm in each pane complete all as specified and directed. 37 Supply and fix rolled mild steel Fe 410-W (Gde-E-250 quality A) in joist, channel, angle, or tee sections, fixed independently as in rafter and purlins without connecting plates, etc. complete all as specified and directed. 38 Material and Labour for preparation of new steel Surfaces and applying two coats of synthetic enamel paint over a coat of red oxide on surfaces of any description, over 10cm in width or girth complete all as specified and directed. 39 Supply and Fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roofcovering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. 40 Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 41 Supply and fix viterous china squatting pan of Orissa pattern size 580x440mm white with integral foot rest(excluding flushing cistern) and flush pipe complete all as specified and directed. 42 Supply and fix in repais vitreous china(Pedestal pattern), of size 580mmx440mm white with integral foot rest with and includingP or S trap, connection to trap and to flushing pipe, trap set in and including provision of lime concrete bedding and taking out old WC and connections etc complete all as specified and as directed 43 Supply and fixPVC valveless, syphonic action type flush tank in repair, white, 10 litre capacity with inlet ball valve, float & handle including brackets complete high level, flush pipes of PVC 32 mm dia, rubber cones, PVC connection 15 mm size with PTMT nut of length 600 mm etc complete all as specified and directed. 44 Supply and fixvitreous chaina wash hand basin white flat back of size 550mm X 400mm, fixed with a set of cast iron brackets including cutting and pinning in ends of brackets to wall, provision of 15mm size pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or cold with long scrwed shanks and fly nuts, 32mm dia brass chromium plated waste fittings 450mm long PVC connection of 15mm size with PTMT nuts and 40mm dia waste pipe complete all as specified and directed. 45 Supply and fixing of soap dish vitreous china coloured approximate size (160mmx160mmx90mm) fixed in repairs complete all as specified and directed. 46 Supply and fix Tubular towel rail 20mm dia(d) type 60cm long between flanges aluminium anodised complete all as specified and directed. 47 Supply and fix 600x450mm be velled edge mirror of selected quality glass mounted on 6mm thick AC building baord or comercial plywood and fixed to wooden plugs with chromium plated brass screws and cup waste washer complete all as specified and directed. 48 Supply and fix in repairs stop/angle valve cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipes or for union & fixed , of bore of pipe 20 mm complete all as specified and directed. 49 Supply and fix bib tap fancy type Chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed bore of pipe 15 mm complete all as specified and directed. 50 Supply and fixing in repairs Pillar taps, cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed fancy type complete all as specified and directed. 51 Supply and fix 1000 Ltr capacity Rotational moulded polythene water storage tanks(cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. 52 Supply and fix ball valves, high pressure,with polythene float and flynut complete ,25mm bore complete all as specified and directed. 53 Supply and fix 110mm PVC(SWR) bends complete all as specified and directed. 54 Material and Labour for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floors/walls as soil pipe complete all as specified and directed. 55 Supply and fix 110X75mm PVC(SWR) reducer complete all as specified and directed. 56 Supply and fix for 110mmPVC (SWR) junction single (single T) equle or unequle with access door complete all as specified and directed. 57 Supply and fix 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. 58 Supply and fix 75mm PVC (SWR) vent cowl complete all as specified and directed. 59 Supply and fix PVC (SWR) floor trap with grating 75 mm dia, plain with CPgrating including jointing with solvent cement complete all as specified and directed. 60 Supply and fix PVC connection 15mm bore size with PTMT nuts of length 45cm complete all as specified and directed. 61 Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. 62 All as per Item No 61 above but for 25mm bore. 63 Supply and fixing in CPVC 20mm Brass Elbow (3/4 x 1/2) complete all as specified and directed. 64 Supply and fixing in CPVC 20mm Brass Tee complete all as specified and directed. 65 Supply and fixing in CPVC 20mm Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified and directed. 66 Supply and fixing in CPVC 20mm Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified and directed. 67 Material and labour for point wiring for one light point controlled by one way switch complete with 1100Volts grade 1.50 Sqmm PVC insulated unsheathed multistranded FRLSH grade copper conductor cable fixed/ drawn through and including white/ ivory colour heavy duty PVC casing/ capping with accessories and fixing on wall/ ceiling including PVC board with cover (ISI marked)for mounting switches, sockets, regulators etc and providing one run of 1.5 sqmm PVC insulated unsheathed multistranded FRLSH grade copperconductor cable as earth continuity wireand connecting to common earth and carrying out IR test for each circuit including making good the disturbed surface by cement mortar 1:3 and matching/ finishing surfaces by distemper/ colour wash as per existing colour surfaces over plaster of paris/ putty complete all as specified and directed. 68 (a) One light point controlled by one way switch. 69 (b) One exaust fan point controlled by one way switch 70 Material and Labour for switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and directed. 71 Supply and fix ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and directed. 72 Supply and fix double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed. 73 Supply and fixtesting and commissioning of MCB SP 240 volt 6 Amp to 16 amp 10 KA capacity having C-series connected with suitable lugs complete all as specified and directed. 74 All as per Item No. 71 above but for SPN 6-16 Amps 75 Material and labour for earthingcomplete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25metre deep below natural ground level) with top edge of the plate not less than 1.5metre below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to main switch board/ main DB’s/ earth test point with and including necessary excavation and earth work in any type of strata, PCC 1:3:6, type C1 in chamber wall with 50mm thick, RCC cover 1:2:4, type B0 duly reinforced with 6 mm diabar, @100mm both way with suitable lifting handle, charcoal dust and common salt mixed and packed in 150mm thick layer all around the earth plate, watering pipe of size 20mm dia medium grade, 0.63mm thick GI sheet funnel with wire mesh, GI protection pipe 15mm dia light grade up to 7.5m from electrode and engraving of earth marking on nearby structure/ building with cement motor 1:4 plate of size 200mm x 150mm x 15mm thick and writing of earth results with paint complete all as shown in electrical plate No. 3 of SSR Part-I complete all as specified and as directed. Note: - On testing if desired earth resistance is not obtained, the earthing will be redone at no extra cost. 76 Supply and Fixing LED light fitting 1 x 20 watt 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible coper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 77 Supply and fix LED light fitting 1x 9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.complete all as specified and as directed. 78 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers including making suitable hole on wall and making good complete all as specified and as directed. 79 Supply, lay and connect cable XLPE Insulated screened,PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 sqmm 2 core including taking down old unserviceable service wire/cable of any size complete all as specified and as directed. 80 Supply and Laying DWC HDPE pipe of outer dia of 50mm and inner dia 40mm polyethylene (PE) with smooth internal and profiled external surface for non-pressure for underground cable including bends complete all as specified and as directed. 81 Supply and fixing galvanised pipe light grade of ISI marked 40 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required complete all as specified and as directed. 82 Supply and Laying in trenches galvanised steel water tubing of medium grade with and inclding all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as requierd at site, laid in trenches including dismantiling and taking out old unserviceable pipe line along with fittings from existing connections complete all as specified and as directed.Note:- (i) Excavation and earth work shall be measured and paid separately under relevant item of Sch A(ii) The rates quoted inclusive of cutting, jointing and testing of the pipe (iii) All other fittings requierd shall be provided by the contractor at his own cost. 83 (a) Bore of tube 25 mm dia 84 (b) Bore of tube 20 mm dia 85 Supply and fix Gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location complete all as specified and as directed. for the following sizes :- 86 (a) 25 mm (1”) dia pipe 87 (b) 20 mm (3/4”) dia pipe 88 Supply and Fix float valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in repairs for 20 mm dia (minimum weight 210 gms) complete all as specified and as directed. 89 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil 90 Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and getting out in soft/loose soil 91 Excavating in trenches, n exc 1.5 m wide and exc 3 m and n.exc. 4.5m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and getting out in soft/loose soil 92 M&L for PCC 1:3:6type C-2 using 40mm graded stone aggregate as in foundation, filling in mass concrete complete all as specified and directed by Engr-in-Charge. 93 M&L for Brickwork with fly ash bricks in one brick thick honey-comb walling, built in CM 1:4 complete all as specified and directed by Engr-in-Charge. 94 M&L for rendering 15 mm thick in CM 1:4 on on fair faces of brick work or concretesurface even and smooth using water proofing compound (WPC) & without using extra cement all as specified and as directed by Engr-in-charge. 95 M&L for Aggregate for loose filling, of gauge 80 mm to 150 mm graded all as specified and as directed by Engr-in-charge. 96 M&L for RCC M 15 Type B1 (using 20mm Graded Stone aggregate) as in bands 97 M & L for RCC M25 (Design mix) for slabs supported on walls beams and columns in floors roofs landings balconies canopies deck slabs and in shelves and like complete all as specified and directed. 98 M & L for drain pipes NP-2 pipe of size 150mm laid in trenches and jointed as specified 99 S & F of LLDPE septic tank on site Conventional designed of capacity 2000 lites to carry sewage and sullage water, excavatioin in any type of soil as requried depth, laying of PCC 1:4:8 below foundation, foundation as per manufacture, hounching of Spetic tank, vent shaft, connection and returning filling duly compacted made leveletc, complete. Make as per Engineer-in-charge direction
Contract Date: May 15, 2025 Contract Value : 23.98 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
49.
Defence #7079476 AOC
Tender For Provision Of Sub Guard Room And Guard Rest Room At Af Stn Darbhanga; 1 Lump sum price worked out by the contractor as per showm on drawing for Building Work as listed in Sch ‘A’ PartI. 2 Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch A Part II. 3 Lump sum price worked out by the contractor for Internal Electrification as listed in Sch A Part III. 4 Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch A Part IV. 5 Lump sum price worked out by the contractor for Path and Hardstanding as listed in Sch A Part V. 6 Lump sum price worked out by the contractor for Area Drainage as listed in Sch A Part VI. 7 Lump sum price worked out by the contractor for Fencing and Gate as listed in Sch A Part VII. 8 Lump sum price worked out by the contractor for Site Development as listed in Sch A Part VIII. 9 Lump sum price worked out by the contractor for External Electric Supply as listed in Sch A Part IX. 10 Lump sum price worked out by the contractor for External Water Supply as listed in Sch A Part X. 11 Lump sum price worked out by the contractor for Earth Work as listed in Sch A Part XI. 12 Price item wise worked out by the Contractor forSchedule `A Part-XII (rate against Srl No. 13.0 to 24.00 shall be quoted by the Contractor) 13 Bringing approved soil (Earth) for filling duly purchasing from out side MoD land complete all as specified and directed. 14 S&F LLDPE septic tank conventional design to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc. complete for 10 users complete all as specified and directed. 15 M&L for Earthing complete with galvanized steel earth plate 600 x 600 x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level (with top edge of the plate not less than 1.5 meters below normal ground level) connected to galvanized iron wire 4.0mm dia as earth lead by means of bolts, nuts, and washers all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earthing test point& to main switch board with and including adequate qauntiy of charcoal dust & common salt in alternate layer around earth plate, 20mm dia pipe light grade for earth lead protection pipe, GI funnel with 20 mm dia medium grade GI pipe for watering and wire mesh includingexcavation and earth work, PCC pit with 1:3:6 Type C1 (Using 20 mm graded stone aggregate) RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia plastering 15 mm thick in CM 1:6 externally upto 150 mm below ground level, and disposal of surplus soil complete including testing and writing test results on a 3.0 mm thick painted MS earth pit marking plate (200 mm x 100 mm) duly welded with a 450 mm long 10mm dia round MS rod fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing with old earth pit chambers and removing of debris from the site complete all as specified and directed.Note: - Earth lead wire and its protection pipe upto and including 15 meter only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid separately. 16 M&L for drilling vertically from average ground level for 125 mm dia bore hole in any type of strata including hard rock by mud flash rotary ring including cost of drilling shall be done by mud flash rotating equipment bore shall be unsealed at least 48 hours to the entire depth of bore holes, depth of bore hole from 0 to 100 meters and removal of drilled/boared materials to a distance not exceeding 50 meter, spreading levelling and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specfied and directed. 17 Supply, install, testing and commissioning of borewell submerssible pumpset of 1.5 HP-13 Stage V4 Series, IP68, insulation class B(i) Power: 1.5 HP (1.12 KW), Voltage: 160-240 Volt(ii) Phase: Single Phase(iii) Head Range: 60 meter(iv) Flow Rate: 70 LPM(v) Outlet: 32 mm(vi) Material: Housing and Shaft-Stainless Steel, Impeller: Noryl, NRV/Suction-Cast Iron(v) Bore Size: 100mm and above bore dia(vi) Winding: Copper(vii) Motor Type: Water filled(viii) Motor Type: water filledNote: Quoted rates are inclusive of reducers/sockets, nutbolts, nipple etc. as required for fixing of pumps with GI/HDPE Column pipes. 18 S&F PVC pipe 6 Kg/sqcm of size 110 mm dia, heavy duty, screwed or socketed type ISI marked complete all as specified and directed. 19 Supply and laying water proof submerssible flat cable PVC sheathed multistranded copper conductor 3 core, 2.5 sqmm, 1100 volt grade, fixing between submerssible pump and control panel complete all as specified and directed. 20 S&F submerssible pump digital controller panel 2 HP, single phase alongwith on/off pushbotton, indicator lamp-01 No complete all as specified and directed. 21 S&F gun metal non return valve 40 mm dia, complete all specified and directed. 22 S&F MS bore well cap suitable for 110 mm PVC pipe including necessary clamps, nut bolt and fixing arrangements complete all as specified and directed. 23 S&F steel wire rope anti corrosive (Stainless Steel) of cage 4 mm thickness for fixing submerssible pumps to bore well cap including necesary nuts, bolts & clamps complete all as specified and directed. 24 Cutting existing CI/DI/GI pipes for alteration or additions if necessasarily fix in position wthout taking down of size upto 200 mm dia complete all as specified and directed.
Contract Date: Mar 22, 2025 Contract Value : 87.92 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
50.
Defence #7036536 AOC
Tender For Provision Of Ladies / Gent Toilets & Additional / Alternator To Roof Parapetsunder Age B/R Iii At Chandimandir; 1 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. 2 Excavation over areas in hard/dense soil not exceeding 1.50 metre in depth and getting out complete, all as specified. 3 Excavation over areas in hard/dense soil exceeding 1.50 metre but n.exc 3.00metrein depth and getting out complete, all as specified. 4 Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. 5 Removal excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified & directed. 6 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. 7 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in flooring etc, complete all as specified and directed. 8 Moorum /red bajri filling as in sub base for floors or pavings, laid in layers n.exc. 15cm thick, spreading, leveling and ramming including watering complete all as specified and directed. 9 Hard core of gauge of broken stone or boulders, not exc 63mm , deposited spread and lavelled in layers n-exc 25 cm watered & rammed to a true surface ,complete all as specified. 10 Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete, all as specified. 11 Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. 12 Plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection, 75mm thick, laid to slope of 1:20, finished even and smooth, with 10mm wide joints to full depth @ 2.5m c/c and at corners, filled with mastic mortar, including dismantling of PCCof complete all as specified and directed. 13 Mild steel TMT bars 10mm dia and over ,cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed. 14 Material and labour for mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified. 15 Plain cement concrete type B-0, 1:2:4 using (2012.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. 16 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate)as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). 17 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate)as in coloumns, pillars etc complete all as specified and directed (reinforcement shall be measured and paid for separately). 18 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5 metre span and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). 19 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate)as in chajja etc, shelves and the like complete, all as specified and directed. 20 Reinforced cement concrete,type A-1, 1:1½:3(nominal mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, balconies, roofs, canopies shelves and the likecomplete all as specified and directed (reinforcement shall be measured and paid for separately). 21 Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed. 22 Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. 23 Form work to sides of pillars, coloumns and similar items (square, rectangular or polygonal) including edges rough finished surface of concrete flat complete all as specified and directed. 24 Form work to soffits of suspended slabs such as roof slabs rough finished surface of concrete flat not exc 200mm thick complete all as specified and directed. 25 Form work to chullah hoods, chajjas and similar items including edges / sides and soffits of lintelsetcrough finished surface of concrete flat complete all as specified and directed. 26 Form Work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work exc10cm but n.exc 20cm wide complete all as specified and directed. 27 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed. 28 Brick work with sub class ‘B’ bricks of old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. 29 All as per serial item No 28 herein before but except bricks (using old serviceable bricks) –ditto- 30 Brick work with sub class ‘B’ bricks ofold size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. 31 Preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper overand including a coat of primer complete all as specified and directed. 32 Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick rendering in cement mortar 1:6 complete all as specified and directed. 33 Glazed ceramic coloured tiles of size 1200mmx600mmx 7mm thick as in dado, set and jointed in neat cement slurry and grouted in white cement complete as on vertical surfaces over and including 10mm thick bedding layer in CM 1:4complete all as specified and directed. 34 Glazed ceramic coloured tiles of size 300mmx450mmx 7mm thick as in dado, set and jointed in neat cement slurry and grouted in white cement complete as on vertical surfaces over and including 10mm thick bedding layer in CM 1:4complete all as specified and directed. 35 Rendering 15mm thickon fair faces of brick worksurfaces, finished even and fairin cement mortar (1:4), inclunding using water proofing compound, complete all as specified.Note : WPC shall be measured and paid separately. 36 10mm thick rendering in Cement and Sand mortar 1:6 over concrete /brick surfacesfinished even and smooth without using extra cement, complete all as specified & directed. 37 5mm thick rendering in Cement and Sand mortar 1:3 concrete surfaces as in ceiling / chajjas facia at any position finished even and smooth without using extra cement complete all as specified and directed. 38 Supply only Integral waterproofing compound, all as specified. 39 Cement concrete tiles 200mm x 200mm x 20mm thickset, jointed and pointed in neat cement slurry with grey cement as in roof tiless, laid over and including 20mm thick screed bed in cement mortar 1:4, complete all as specified and directed. 40 Preparation of new plastered surfaces of walls and applying two coats of cement base paint (any colour) including all necessary scaffolding and safety arrangements, complete all as specified and directed. 41 Vitreous china squatting pan, “Orissa” pattern size 580mm x 440mm white, with integral foot rests(excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, set with cement concrete, complete all as specified & directed. 42 PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection with PTMT nuts and 32mm dia CP flush pipe (long type for squatting pan), complete all as specified & directed. 43 Single Piece WC with UF Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fitting, Fixing Accessories, Size: 375x650x800 mm, P Trap- 180 mm, fixed in position, complete all as specified and directed. Make : Jaguar ARS-WHT-39751P180UFSMZor equivalent as approved in Appx C 44 Viterous china bowl 385x325x635 urinal with Consealed sensor, ivory/ white colour with CP Brass urinal spreader, urinal coupling CP Brass and discharge pipe including providing & fixing plugs, waste pipe , bedding urinal against wall in CM 1:2, securing urinal to plugs screws, pointing around urinal back in white cement complete all as specified and directed.Make : Urinal : Jaguar-URS-WHT-13253N, Urinal Sensor: Jaguar-SNR-STL-51087or equivalent as approved in Appx C 45 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type moulded door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. 46 Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. 47 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement,complete all as specified & directed. 48 PVC(SWR) waste pipe, 110mm bore, single socketed in any length with cement/ rubber ring joints, laid in trenches or infloor,complete all as specified and directed. 49 PVC(SWR) waste pipe, 75mm bore, single socketed in any length with cement/ rubber ring joints, laid in trenches or infloor,complete all as specified and directed. 50 PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc,complete all as specified and directed. 51 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed. 52 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed. 53 4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading)in square n.exc 0.5 Sqm in each panes complete all as specified and directed. 54 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, float valve, ball valve 20mm PTMT,compelte all as specified in SSR Part-I and all as directed by Engineer-in-charge. 55 Table top wash basin, of Size 575x 430 x 175mm, white colour, including waste pipe, CP angle valve, CP waste coupling etc fixed in position,complete all as specified and directed.Make : Jaguar Cat Part ACS-WHT-87901 or equivalent as approved in Appx C 56 Beveled edge looking mirror, 5.5mm thick of selected quality glass, including wood finish PVC mouldingmounted on 6mm thick ply or of PVC frame fixed to wall with screw and rawl plugs,complete all as specified and directed. 57 Steel water tubes, 15mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors,complete all as specified and directed. 58 Steel water tubes, 20mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors,complete all as specified and directed. 59 Steel water tubes, 25mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors,complete all as specified and directed. 60 Bib tap, short body, fancy typecast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union,suitable for 15mm bore pipe, complete all as specified and directed. 61 Brass stop valve,screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 20mm bore pipe,complete all as fixed as in repair specified and directed. 62 Stop valve, cast copper alloy, chromium plasted screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed. 63 4mm thick False ceiling fibre cement board, white in colour , 595mm x 595mm in size, fire and moisture resistance, fixed with and including standard GI snap grid framing (Powder coated) and suspended not exceeding 900mm below from ceiling with 3mm dia wire including clips and misc fittings etc in pattern as approved by GE, fixed as in repair (size of panel shall be of 605 x 605mm and GI snap grid framing shall be of 1mm thick standard section i.e. channels, angles, tee etc),complete all as specified and directed. 64 10mm thick toughned glass as in partitions and similar work including cutting to shape, drilling holes required complete all as specified and directed. 65 Granite stone slabs, 16 to 18mm thick,width and length as per site requirement, best qualitymachine cut andpolished to be fixed infloors,cooking plateform, tread, raiser of steps and vertical surfaces etc and jointed with gray cement slurry and pointed in white cement mixed with marble dust (1:2) with admixture of pigment to match the shade of slab, rubbing, cutting / rounding of edgesand corners where required with and including 15 mm thick screed bed in cement mortar 1:4, Complete all as specified and directed. 66 Hand Shower (Health Faucet) with 8mm Dia, 1 Meter Long Flexible Tube & Wall Hook with N.R.V (Back Flow Preventer), fixed in position, complete all as specified and directed. Make : Jaguar Cat Part ALD-573 or equivalent as approved in Appx C 67 Sensor operatedcast copper alloy chromium plated Tall body pillar tap opal prime sensor faucet for wash basin (9V transformer) complete all as specified and directed. Make : Jaguar Cat Part SNR-15017PMEB or equivalent as approved in Appx C 68 PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specified and directed. 69 75mm size,butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge. 70 200mm aluminum anodized barrel tower bolts of extruded section, complete all as specified. 71 150mm size aluminium handle (ISI Marked), cast type, anodised complete all as specified & directed 72 Plain cement concrete type C-2, 1:3:6 using 40mm graded crushed stone aggregate as in bed to drain pipes including cradle of 150mm bore pipe after the pipes are laid and tested , complete all as specified and directed. 73 RCC pipes class NP2150mm dia bore, with collars, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed (excavation, earthworkand PCC shall be measured and paid for separately) 74 Demolition of brickwork built in cement mortar or cement lime mortar, including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed 75 Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar, demolition of mud phuska of any thickness includingremoval of rubbish from site complete all as specified & directed. 76 40mm thick brick tileswith including 20mm thick cement mortar 1:4 jointedgrouted and pointed complete mixed with crude oil5%by weight of cementcomplete all as specified and directed. 77 All as per serial item No 76 herein before but except tiles –ditto- 78 PCC 1:3:6 type C-1 (20 mm graded stone aggs) as in roof padding, roof kerbs rounded or chamfered on edgescomplete all as specified and directed. 79 Demolition of reinforced cement concrete of any description, in any position not specifically provided for, complete all as specified and directed. 80 Taking down cement plaster on brick / stone walls or ceiling (up to 10 mtr height) including raking out joints, hacking for key, scrubbing down with water, etc , complete all as specified and directed. 81 Rendering 15mm thick (average thickness) plaster in cement mortar 1:4 mixed with WPCon concrete roof surfaces including flashings and junction of parapets etc ,finishing the surface even and fair without using extra cement all as specified and directed by Engineer-in-charge. Note :- WPC will be measured & paid separately as supply only). 82 3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, over primer coat bonding material of blown bitumen 85/25 grade heated to working temperature of 180° C applied @1.2Kg/Sqm. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructionsincluding dismantling of existing felt /treatment, complete all as specified & directed. 83 Preparation of new surfaces of any description of wall, facia, ceiling, RCC etc and applying two coats of oil bound destemper over one coat of interior wall primer including wall care putty (average thickness 1.5 to 2.5mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering for making the surfaces even and smooth complete all as specified and directed. 84 Complete removal of existing treatment of any type/ descriptin viz distemper, white wash etc from plastered / un plastered surface of wall, chajjas, facia, cantilivers, RCC etc with mechanical means / grinder completely and applying two coats of oil bound distemper over and including one coat of interior wall primer including interior grade wall care putty (thickness vary from 1.5 to 2.5mm as required for desired smoothness and leveling of surfaces in two or more layers)and sand papering, making the surfaces even and smoothcomplete all as specified and directed. 85 Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0,all as specified and directed. 86 Two coats of synthetic enameled painton steel and iron surfacesover 10 cm width or girthincluding preparation of new surfaces complete all as specified & directed. 87 Repair to RCC sunshades, chajjas, balconies, coloumns, bands, beams and similar RCC work at any position / height by dismantling loose / disintegrated portion including necessary scafolding and safety arrangements and dubbing out with cement concrete 1:1.5:3, 20mm thick, using 6 to 12mm graded stone aggregate to make up and finished the required shape including provision of necessary scaffolding and formwork up to three storey bldg if required and finished with 5mm thick rendering in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and directed. 88 Preparation of old existing plastered / unplastered surfaceand applying two coats of exterior emulsion paint in approved tint over one coat of exterior wall primer on existingsurface of building(all as per manufactures instructions) with and including necessary scafolding and safety arrangements complete all as specified and directed. 89 Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified & directed by Engineer-in-charge. 90 1mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed with self tapping screws etc complete all as specified & directed . 91 Conventional LLDPE septic tank of capacity 1000 litre, designed to carry sewage and sullage water, connection etc complete all as specified and directed. MAKE : SINTEX or equivalent as approved by Engineer-in-Charge 92 Precast SFRC cover of size 1200 x 600mm complete all as specified and directed. 93 Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. 94 All as per serial item 93 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed 95 All as per serial item 93 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 96 All as per serial item 93 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor 97 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 98 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 99 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. 100 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 101 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 102 Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 103 LED lamp9 watts, B-22 type complete all as specified . 104 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. 105 MCB, SP, 240 volt,40 Amps, 10 KA , B series including connection with suitable size aluminium / copper lugs complete all as specified and directed 106 MCB ,SP, 240 volt, 6 Amps to 32 Amps, 10 KA , C series including connection with suitable size aluminium / copper lugs complete all as specified and directed 107 LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable sizefixed as in repair complete all as specified and directed. 108 Slim LED lights fitting, 4 feet,1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. 109 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cableshall be considered as 1 running metre. (ii) colour code shall be Red for phase, Black for neutral and green for earth 110 LED panel surface mounted -2x2 - 36 wattscool day light fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed complete all as specified and directed. 111 Ultorn 17 watt wall light 220 volt (warm white) size 54.50cm x 10cm x 3.50cm including connecting up with three core flexible copper conductorcabble of suitable size complete all as specified and directed. 112 ABS plastic1800W White Crescent Wall Mounting hand dryer machine (ISI Marked) suitable for bathroom compelte all as specified and directed. 113 Wall mounted type automatic sanitary NakshatraTechnologyautomatic sanitary napkin destroyer incinerator machine 230 volt of capacity 8 to 10 Napkins per load , of size 230 x 230x 320mm for ladies toilet complete all as specified and directed.MAKE : NAKSHATRA, Model Blue or equivalent as approved by Engineer-in-Charge. 114 Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed. 115 Flourish waterproof classy and smart look bollard garden light grey, with bulb corded electric metal, including connection complete all as specified and directed. 116 XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 2core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. 117 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter
Contract Date: Feb 11, 2025 Contract Value : 49.75 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
TenderDetail
Loading tenders