View Bid Results For Network Gateway Tenders

We found 198 Bid Results related to network gateway tenders. You can find Contractor details who won network gateway tenders along with contract details in Bid awards announcements section.

Filters
Stage
164
21
13
Tender Publishing Platform
91
107
State / UT
28
26
24
22
20
14
12
9
9
7
6
5
5
5
5
4
3
3
3
3
2
2
2
2
1
1
1
1
1
Contract Value
38
26
79
55
Publish Date
1
1
0
0
0
Sector
27
40
23
22
13
13
13
12
10
8
7
6
4
4
3
2
2
2
2
2
2
1
1
1
1
1
1
1
Ownership
5
105
46
35
10
1
Within keyword
Active filters:
Showing 1–4 of 198 tenders matching your filters
1.
Communications and Information Technology  #11475627 Technical Bid
Tender for Tender For Supply, Installation, Commissioning And Maintenance Of Cctv Systems For Igr 3.0 Project Under Lease Cum Service Model For A Period Of 5 Years , Annexure - 13 Price Bid , Cctv Camera 2 Mp With 512 Gb Sd Card With Voice Recording , 8 Ch Nvr , 20 Tb (10*2) Hard Disk , 8 Port Gigabit Layer 2 Poe Switch , Cat 6 Network Cable (For Connecting Three Ip Cameras, Nvr And Desktop Computer) (Unit Cost In Mtr To Be Quoted) , Desktop Computer For Sro Office , Monitor 27 For special repair View With 15 Mtrs Hdmi Cable , 1 Kva Ups With 120 Min Backup With Mcb , Earthing Systems In All Sro , Labor Charges For Lan Cabling And Related Services Including Ip Configuration. 1 Pvc Pipe With Fixtures (Cat 6) , Ups Output Wiring From 1 Kva On-Line Ups To Desktop And 6U Rack (3C*2.5Sq.Mm) , Labor Charges For Ups Wiring And Related Services, 1 Pvc Pipe With Fixtures , 2* 5 A Switch And Socket , 1 *15 A Ss Combined , Active Led Videowall With Controller , Display Monitor 55 Inch , 24 Port L3 Ethernet Switch With 4 Sfp+ Port , Workstation For Dig & Ig Office For Vms Client & Workstation For Time And Attendance Database And Application Hosting , 42 U Server Rack Customisable - Ig Office , 24 U Server Rack - Dig Office To Place Ai Servers , Centrally Managed Cloud Platform Required For Whatsapp Integration - Secured Storage, Video Dissemination. Cost For Software Support, Enhancement , Server For Video Management Platform (3 Nos) - 3 Numbers Of Physical Server Or Equivalent Solution To Offer Useable Resources Of 48 Cores/ 512 Gb/ 12 Tb Of Storage Post 1 Node Failure , Management Portal To Store And Send Registration Videos , Time And Attendance Management Software As Per Technical Requirements , Finger Print Scanner With Software Kit , Server For The Video Management Software- Igr Ho (Management) , Server For The Video Management Software- Igr Ho (Streaming) , Server For Ai Functions (11 + 1) , Vms Licenses For 3000 Cameras With Client Login , Ai Functions Vms Licenses For 600 Cameras - special repair Camera1 , Alternate Gateway For Tnega Whatsapp Gateway , Manpower-1 Ipc Operator/Deo- Year1 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower-1 Ipc Operator/Deo- Year2 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower-1 Ipc Operator/Deo- Year3 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower-1 Ipc Operator/Deo- Year4 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower-1 Ipc Operator/Deo- Year5 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year1(Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year2 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year3 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year4 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 2- Team Leader -Year5 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year1 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year2 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year3 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year4 (Unit Cost Per Resource Per Year To Be Quoted) , Manpower 3- L2 Engineer -Year5 (Unit Cost Per Resource Per Year To Be Quoted) , Setting Up Necessary Infrastructure In Igr Office For Running All Server Services Such As Ups, Genset, Ac, Rack, Network Cables, San Switch, Router, Static Ips, Fire Wall, Plug Points, Installation Of Ports And Other Required Accessories - Qty - As Required To Meet The Sla , Aggregation Bandwidth With Back Up Connectivity For 5 Years , Comprehensive annual maintenance contract Of Existing 1150 Ip Camera In Record Room (S) Of Sro (Unit Cost For 5 Years Per Camera To Be Quoted) , Integration Of 1150 With New System , Shifting Cost For Ip Camera And Other Related Infrastructure From Sro Office To Another. , Cost For Ip Camera Installation Setup In New Office - For New Office 5 No Ip Camera, 2 No Nvr, 2 No 8 Poe Port Switch, 20 Tb Hdd, Computer, Monitor, Ups Installations Commissions As Per Technical Specifications Each Items In Above
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 5
2.
Defence #11453177 AOC
Bids Are invited for Ceiling Speakers , Column Array Speakers , Lifier For Ceiling Speakers , Lifier For Column Array Speakers , Digital Signal Processor , Boundary Layer Microphones , On Off Button For Boundary Layer Microphones , Switch Box For Boundary Layer Microphones , Ceiling Tile Microphone Array , Main Display , Side Display , Annotation Panel , Cable Manager For Table , Hdmi Switcher , Hdmi Splitter , Hdmi Extender , Usb Tx Multiformat Switcher , Usb Rx Multi Format Switcher , Usb Data Matrix Switch , Ptz Camera , Speaker Tracking Camera , Hdmi To Usb Capture Card , Voice Tracking Device , Control System With Touch Controller , Network Switch , Room Scheduler , Pdu With Humidity And Temperature Sensor , Ceiling Mount Document Scanner , Equipment Rack , Ups 10 Kva Ups With 60 Min Backup , Ups 3 Kva Ups With 60 Min Back Up , Acoustic Door With Fitting Laminate And Door Frame , Chair , Hot And Cold Ac 2 Ton , Room Air Purifier , Bio Metric Door Access Control , Auto Fire Suppression System For Av Rack , High Quality Wireless Keyboard And Mouse , Led Surface Recessed Mounted Panel With Luminous Web , 12 Channel Signal Dimmer Controller , 12 Channel Controller , Display Keypad Panel For Workstations , Network Router For Automation System , Sitc Supply Installation Testing And Commissioning , Acoustic Wall Paneling , Acoustic False Ceiling , Wooden Conference Table , Executive Chair , Acoustic Carpet Flooring , Power Supply For Lighting Control Network , Lighting Control Communicaiton Gateway Total Quantity : 4070
Contract Date: Ref. Documents Contract Value : 3.84 Crore
Government Departments No of Bidders 4
4.
Civil Aviation #11346997 AOC
Bids Are invited for Supply of 24 Port L3 PoE Network Switch with all 1G SFP port - 24 Port L3 Core Switch 04 Fiber Port , Supply of 24 Port L2 PoE Network Switch with 1G SFP port-4 - 24 Port L2 POE Managed Switch 04 Fiber Port , Supply of 1 G SFP LC LR 10km SMF Transceiver - 1 G SFP LC LR 10km SMF Transceiver , Supply of IP Phone as per Specification , Supply of Digital Phone as per specification , Supply of Operator Console , Supply of FXS Gateway - 32 Port FXS Gateway , Supply of Cat6A STP Cable , Supply of PVC Conduit Pipe with Jointer Band - PVC Conduit 32mm for laying of OFC Cable/ Cat6 Cable inside building , Supply of 12 port LIU with pigtail , Supply of 12 Core SMF OFC Cable , Supply of RC Cable - 1 Pair RC Cable , Supply of OFC patch cord-1 Mtr - OFC Patch Cord Single Mode LC-LC Duplex- 1Mtr , Supply of OFC patch cord-3 Mtr - OFC Patch Cord Single Mode LC-LC Duplex- 3Mtr , Supply of 24 port Cat6A Patch Panel , Supply of Cat6-A IO Box Single RJ45 Port with Face Plate and IO Jack , Supply of 1U PVC Cable Manager - 1U PVC Cable Manager , Supply of CAT6-A RJ45 Patch Cord 1 MTR - Cat6-A RJ45 Patch Cord 1 MTR , Supply of CAT6-A RJ45 Patch Cord 2 MTR - Cat6-A RJ45 Patch Cord 2 MTR , Supply of 42U Floor Mounting Network Rack - 42U floor Mounting Network rack with Cable Manager and PDU with accessories , Supply of 27U Floor Mounting Network Rack - 27U Floor Mounting Network rack with Cable Manager and PDU with accessories , Supply of Copper plate Earthing - Copper plate with Earthing , Supply of 3 core 6 sqmm multi strand PVC insulated PVC sheathed copper conductor power cable - 3 core 6 sqmm multi strand PVC insulated PVC sheathed copper conductor power cable , Supply of 16 AMP Dual Pole MCB with Box - Supply of 16 AMP Dual Pole MCB with Box for connect to Rack UPS , Supply of installation Accessories - LAN Tester-2 RJ45 Crimping Tools-2 , RJ45-200 nos UV Protected nylon cable ties-500 etc & any other accessorises per site requirements , ITC of the complete system alongwith documentation , 1st Years comprehensive AMC with Spare after warranty - CAMC , 2nd Years comprehensive AMC with Spare after warranty - CAMC Total Quantity : 16056
Contract Date: Ref. Documents Contract Value : 1.44 Crore
Boards / Undertakings / PSU No of Bidders 6
Uttar Pradesh View Result →
5.
Railways #11287401 AOC
Supply Of supply installation testing and commissioning of gateways as per schedule of requirements , supply, installation, testing and commissioning of dcus/gateways/ allocation of sim network service provider and the arrangement of sim cards to enable reliable medium for two-way communication between smart meter & amp:, hes (head end system) over rf mesh network/cellular network. 1. the dcu/ gateway shall be compatible with the smart meters mentioned above. rf mesh network should use 865-86 7 mhz frequency band. 2. the data acquisition (push/pull) frequency shall be configurable 15 min, 30 min o r 60 minutes. it shall push events such as tamper, power off etc. to hes immediately on occurrence/receipt from meters. 3. it shall have provision for the cellular, wifi and ethernet communication for the backhaul to hes. 4. sufficient number of gateways shall be installed in such a way that all the meters are covered in th e network efficiently. 5. it shall be capable to handle data of minimum 500 nos. of any type of smart meter (1ph/3ph). it shall be able to communicate with the nearest meters at a distance of at least 300 m, dependi ng on topographical features. 6. communication of the nearest meters with other meters shall be establish ed through appropriate mesh formation. rf mesh shall support self-forming and self-healing features. 7. rf mesh shall support at least 15 no. of hops. 8. the equipment shall be weather-proof and dust-proof (minim um rating: ip54 for indoor and ip65 for outdoor installation). it shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc. 9. it sha ll have passed the following emc tests from reputed lab: conducted emission, electrostatic discharge (esd ), radiated immunity, electrical fast transient (eft) - burst, surge, rf conducted disturbances. 10. rf mes h network shall be established to meet the slas as mentioned in tender document. 11. replacement warra nty period shall be 66 (sixty-six) months from the date of supply or 60 (sixty) months from the date of com missioning, whichever is earlier. [ warranty period: 30 months after the date of delivery ] ]
Contract Date: Jun 15, 2026 Contract Value : 13.18 Lakh
Government Departments No of Bidders 1
7.
Civil Aviation #11203251 AOC
Bids Are invited for Product 1 - Supply Of Dual Server Gateway Based Ip Pbx System In Raid 1 Storage Configuration. , Product 2 - Supply Of Executive Ip Phones With 2 Way Speaker Phone , Product 3 - Supply Of Poe Based Ip Phones , Product 4 - Supply Of 24 Port L2 Plus Managed Poe/Poe+ Switch With Fully Loaded Sfp Modules Single Mode Transceiver. , Product 5 - Supply Of 16 Port L2 Plus Managed Poe/Poe+ Switch With Fully Loaded Sfp Modules Single Mode Transceiver. , Product - Supply Of 8 Port L2 Plus Managed Poe/Poe+ Switch With Fully Loaded Sfp Modules Single Mode Transceiver. , Product - Supply Of 24 Core Core Armoured Single Mode Ofc Cable , Product - Sitc Of Licensed (Perpetual) Nms Software (Software For Monitoring The Health Of All Ip Devices Of The Network On Single Window). , Product - Supply Of Corded Analog Phone With Cli , Product - Sitc Of Management Platform Inclusive Of Management Software Of Epbax System With Perpetual License , Product - Supply Of Licensed (Perpetual) Recording Application (To Be Played At Operator Console) , Product - Supply Of Pc Based Ip Operator Console In Raid 1 Storage Configuration With Licensed Version Of Software(Latest) , Product - Supply Of Laptop Based Ip Operator Console With Licensed Version Os And Ms Office (Latest) , Product - Supply Of Cat 6A Cable Industrial Grade Including Capping, Casing, Conduiting Fasteners With All Materials. , Product - Supply Of Cat 6A Utp Patch Cord 3 Meter Each. , Product - Supply Of 3 Core Power Cable 2.5Mm Each Core. , Product - Supply Of Intermediate Distribution Frame Idf For 100 Pairs , Product - Supply Of Intermediate Distribution Frame Idf For 20 Pairs , Product - Supply Of Intermediate Distribution Frame Idf For 200 Pairs , Product - Supply Of Intermediate Distribution Frame Idf For 400 Pairs , Product - Supply Of 0.5Mm, 50 Pair Copper Cable (Armourd). , Product - Supply Surge Protection Device For Idf Krone Type (10 Pair In Each Krone). , Product - Supply Of 0.5 Mm, 20 Pairs Telephon
Contract Date: Ref. Documents Contract Value : 1.39 Crore
Boards / Undertakings / PSU No of Bidders 6
Maharashtra View Result →
8.
Defence #11106751 Technical Bid
Tender For Development, Installation And Commission Of Ground Segment Hub For Voice And Data Communication; A1 9.0 Mitr (typical) C-band Antenna System (k) Antenna Mount, Structural, Mechanical Motorized Drive Systems along with motors, Encoders. Limit Switches for Az El and Feed (Polj movement 4-Port Feed System Qty 01 No (m)Around 100 Mtr Civil Trench with covering B cable hanger for interconnecting Antenna with Earth Station Main Trench-Qty-01 No in) 01 no. of Aritenna Lightning Protection 801 no. of Antenna Grounding (0) installation of 9.0Mtr C-band Antenna System and interface Accessories A2 AS Antenna Control Unit (ACU) along with 100 Mt control cable Beacon Tracking Receiver A4 Dehydrator 8.5 32 KWatt C-band High-Power Power Amplifier with Built-In redundancy along with BUC and outdoor housing 8.6 C-band LNA System with complerte 1:1 Redundancy systern along with acne 57 5G Interference Rejection Filter (Pass Band -1680 GHz to 4 200 GHz Downconverter with internal redundancy module Input Frequency (C-band)-3400-4200 GHz Output Frequency (L-Band) 950-1750 MHz Waveguide Switches, Dummy Load and Directional Coupler for Tix and Rx Chain and accessories C10 Equipment Racks along with power distribution unit comprising of (g) FRF Racks-02 Nos (1) Baseband Racks-08 Nos C11 Berver Rack-02 Nos Spectrum Analyzer (Frequency Range KHz to 26.5 GHz) 5 C. 12. Liaisoning to obtain licenses from WPC DOT and NOCC Clearance F26 40 KVA 3-Phase UPS in 1:1 Hot Standby Configuration along with accessories F:27 60 KVA 3-Phase DG Set in 1:1 Hot Standby Configuration along with accessories Milestone-4: Installation of Hub Basebar Description of Items C.13 Hardware for Multichannel Hut Modem C14 Development and porting of Baseband Firmware on Multichannel Hub Madam Hardware C.15 Hardware for Network Control Centre (NCC) with 1.1 Redundant Configuration C.16 Development and porting of software for Network Control Centre (NCC) comprising of comprising of NMS and GIS on NCC Hardware C.17 Terrestrial Interface Gateway (TIG) C. 16. Hardware for Server access unit (SAU) C.19 Development and porting of SAU software on SAU Hardware C20 NMS Client comprising of separate clients for four different Users C.21 Separate Display for NMS and GIS (2 No Eachy 022 24 port managed gigabit switch 0.24 Mini-Test Hub (Scale down version of Hub Baseband System) comprising of (K) NCC along with deployment hardware-Qty: 01 No. (1) Terrestrial Interface Gateway with support for 10 voice calls-Qty: 01 No (m)Server Access Unit with support for 10 data calls-Qty: 01 No. (n) HUR MODEMs Hardware for MST, HST and SMT network with support for 10 Qty: 01 No. (0) 24 port managed Gigabit sattch-2 Nos ... more in document
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttarakhand View Result →
9.
Educational and Research Institute #11098868 AOC
Tender For Iehe Bhopal Invites Online Tender For Supply Of Sound System In The Institute , Sound System , Wall Mount Cabinet Loudspeaker General Requirements: The Loudspeaker Shall Be A Cost-Effective, 12W General-Purpose Cabinet Speaker Designed For Indoor Surface-Mount Applications. It Must Be Suitable For Both High-Quality Speech Intelligibility And Background Music Reproduction Acoustic Performance: Rated Power: 12W, With Adjustable Power Tappings At 12W, 6W, And 3W To Allow For 3 Db Step Adjustments. Sound Pressure Level (Spl): Must Provide A Maximum Special Of 102.0 Db At 6W/1M (1 Khz) And A Sensitivity Of 91.7 Db At 1W/1M (1 Khz). Frequency Range: The Effective Frequency Range Shall Be From 150 Hz To 15 Khz. Opening Angles: Horizontal: 184° (1 Khz) / 86° (4 Khz). Vertical: 66° (1 Khz) / 58° (4 Khz). Electrical Specifications: Input Voltage: Designed For 100 V Line Systems. Rated Impedance: 833 Ohms. Connection: Shall Feature A 4-Pole Push-In Terminal Block On The Rear Panel For Easy On-Site Wiring And Power Tapping. Durability: The Unit Must Be Tested For 100 Hours Of Continuous Operation At Rated Power In Accordance With Iec 268-5 Standards. Mechanical Construction Enclosure Material: The Main Body Shall Be Constructed From Solid Mdf (Medium Density Fiberboard) Covered In Durable, Easy-To-Clean Black Vinyl. Front Grille: The Front Shall Be Abs Plastic Covered With A Fine Woven Cloth In Matching Black. Baffle Design: Shall Feature An Angled Front Baffle To Optimize Sound Distribution Within The Listening Area. Mounting: The Rear Panel Must Include Three Keyholes For Quick And Secure Wall Mounting. Dimensions: 445 Mm X 151 Mm X 150 Mm / 111 Mm Environmental Limits: Operating Temperature: -5 °C To +55 °C, Storage Temperature: -40 °C To +70 °C , Wireless Microphone System General System Requirements: Classification: The System Shall Be An Entry-Level Professional Wireless Microphone System Designed For Ruggedness And Ease Of Use In Daily Operations. Ease Of Setup: The System Must Include A One-Button Automatic Frequency Scanning Function To Identify The Clearest Available Channel. Transmitter Synchronization Shall Be Achieved Via An Infrared Data Link To Ensure Error-Free Setup. Frequency Management: The System Shall Provide 32 Preset Channels, With Compatible Groups Of Eight Channels For Simultaneous Multi-Channel Use. Operating Bands: The System Shall Be Available In Multiple Rf Frequency Bands, Including: A Band: 618-634 Mhz. B Band: 678-694 Mhz. C Band: 516-532 Mhz. E Band: 850-865 Mhz. Receiver Specifications Type: Synthesized Pll With True Antenna Diversity To Ensure Stable Rf Reception. Chassis: The Receiver Must Feature A True Rack-Mountable Metal Chassis Suitable For Professional Installation. Rf Performance: Sensitivity: 1.0 Μv For 12 Db Sinad. Image Rejection: Greater Than 55 Db. Audio Outputs: Balanced Output: 20 Dbv (Max @ 40 Khz Deviation). Unbalanced Output: Adjustable From 8 Mv To 0.755V Rms. Display: Front-Panel Backlit Lcd Displaying Channel, Frequency, And Battery Status. Handheld Transmitter Construction: The Transmitter Shall Feature A Rugged Metal Body Designed To Withstand The Rigors Of Daily Use. Microphone Capsule: Equipped With A Cardioid Dynamic Capsule (Pl22) For Effective Feedback Control And Ambient Noise Rejection. Battery Life: Must Operate For A Minimum Of 14 Hours Using Two Aa Alkaline Batteries. User Interface: Features A Backlit Lcd Display And A Dedicated Mute Function To Protect The Audio Channel. Bodypack Transmitter Construction: Compact And Rugged Metal Enclosure. Input Connector: Industry-Standard Ta4F Connector For Compatibility With Various Lapel Or Headworn Microphones. Antenna: Flexible External 1/4 Wave Antenna. Acoustic & Environmental Performance System Frequency Response: 80 Hz - 18 Khz ± 2 Db Signal-To-Noise Ratio: 100 Db A-Weighted Total Harmonic Distortion: 1.0%, 0.4% Typical (Ref 1 Khz, 40 Khz Deviation) , Professional Gooseneck Microphone General Requirements: The Microphone Shall Be A Professional-Grade, High-Quality Electret Condenser Gooseneck Microphone Designed For Public Address Applications Such As Lecterns, Podiums, And Open Conferences. It Must Feature A Sleek, Slender, And Unobtrusive Design To Maintain A Clear Line Of Sight For The User. Acoustic & Technical Performance Transducer Type: Electret Condenser. Polar Pattern: Unidirectional (Cardioid) To Ensure High Front-To-Back Rejection, Providing More Gain Before Feedback. Frequency Response: Wide Range From 20 Hz To 18,000 Hz. Sensitivity: 7.5Mv/Pa Power Requirement: Operable Via A Dc Power Source Ranging From 1.5V To 9V. Mechanical Specifications Overall Length: 585 Mm (Approximately 23 Inches) Output Connector: Built-In 3-Pin Xlr Male Socket For Secure And Standard Professional Connectivity. Optional Accessories (Compatibility) To Ensure System Flexibility, The Microphone Must Be Compatible With The Following Manufacturer-Specific Accessories: Microphone Base: A Sturdy, Heavy-Duty Die-Cast Aluminium Base With An Integrated On/Off Switch, Led Indicator, And Built-In Housing For 2 Times 1.5V Um-3 Aa Cells To Power The Condenser Element. Mic Stand Adaptor: A Rugged Aluminium Die-Cast Body With A Female Xlr Connector For Direct Mounting And A Male Xlr Bottom Connector For Cable Attachment. It Must Include A 10-Meter Shielded Cable And A Threaded Brass Ferrule 5/8 27 Tpi For Standard Stand Mounting. , Mixer Amplifier General System Requirements Type: The Unit Shall Be A Professional 120W Mixer Amplifier With Integrated Usb And Bluetooth Capabilities, Designed For Public Address And Background Music Applications. User Interface: The Amplifier Shall Feature A Simplified User Interface With Preferred Setting Indicators (Colored Pins) For All Front-Panel Knobs To Ensure Ease Of Operation For Non-Technical Users. It Must Include An Led Vu Meter For Visual Output Level Indication And A 6.3 Mm Headphone Socket For Monitoring The Mixer Output. Reliability: The Unit Shall Have No Moving Parts (Such As Hard Drives) To Ensure Long-Term Operational Reliability. Audio Inputs And Media Source Microphone/Line Inputs: Four (4) Balanced Inputs, Switchable Between Microphone And Line Level Sensitivity. Switchable Phantom Power Must Be Available To Support Condenser Microphones. Priority Handling: Input 1 Shall Have The Capability To Take Priority Over All Other Inputs Via Contact Closure (Push-To-Talk) And Include An Optional 2-Tone Chime To Precede Announcements. Music Source: Integrated Media Player: Must Support Playback Of Mp3 And Wav Files (From 32 Kbit/S) Via A Usb Pen Drive (Up To 32Gb Capacity). Wireless Streaming: Built-In Bluetooth For High-Quality Audio Streaming From Mobile Devices. Remote Control: The Unit Must Be Supplied With An Ir Remote Control For The Integrated Music Source. Aux Input: A Separate Stereo Cinch Input, Internally Converted To Mono, With A Sensitivity Of 200 Mv To 300 Mv. Audio Performance And Output Output Power: 120W Rated Output Power. Loudspeaker Outputs: Constant Voltage: 100 V. Low Impedance: 4-Ohm. Call-Only Output: A Dedicated 100 V Call-Only Channel For Priority-Only Areas Or 3-Wire Remote Volume Control Override. Frequency Response: 80 Hz To 18 Khz (+1/-3 Db At -10 Db Ref. Rated Output). Distortion: 1% At Rated Output Power (1 Khz). Tone Control: Dedicated Bass And Treble Controls Providing Max ± 8 Db Adjustment. System Protection: An Integrated Limiter Circuit Must Be Included To Protect The Output Stage From Signal Clipping And Overload. Insert Feature: A Pair Of Rca Cinch Connectors Shall Be Provided To Allow The Unit To Be Used As A Separate Pre-Amplifier And Power Amplifier. Mechanical And Environmental Dimensions: 100 Mm X 430 Mm X 290 Mm (Standard 19 Wide, 2U High). Mounting: Suitable For Both Stand-Alone Use And 19 Rack Mounting. Operating Temperature: -5 °C To +45 °C. Compliance: The Unit Shall Comply With Iec 62368-1 (Safety), Cispr 32 (Emc Emission), And En 55103-2 (Emc Immunity). , Mixing Console General Requirements The Mixing Console Shall Be A Compact, Versatile 6-Channel Analog Mixer Designed For A Wide Range Of Professional Audio Applications. It Must Feature High-Quality Microphone Preamplifiers And A Rugged Construction Suitable For Both Portable And Fixed Installations. Audio Inputs And Processing Input Channels: The Unit Shall Provide A Total Of 6 Line Inputs, Configured As 2 Mono And 2 Stereo Channels. Microphone Preamplifiers: The Console Shall Include 2 Microphone Inputs Featuring Discrete Class-A D-Pre Preamps With An Inverted Darlington Circuit For Superior Sound Quality. Switchable +48V Phantom Power Must Be Available For All Microphone Inputs. Channel Processing: Mono Inputs (Ch1-2) Shall Include A 26Db Pad For High-Level Sources. Each Mono Channel Shall Feature A High-Pass Filter (Hpf) Set At 80Hz With A 12Db/Octave Slope. Equalization For Mono Channels Shall Consist Of A 2-Band Eq: High (10Khz Shelving) And Low (100Hz Shelving) With Pm15 Db Adjustment. Output And Bus Section Buses: The Console Shall Feature 1 Stereo Bus. Outputs: Stereo Out: Provided Via 2 Xlr-3-32 And 2 Phone Jacks (Balanced). Headphones: One (1) Stereo Phone Jack Output With A Dedicated Level Control. Monitoring: Visual Monitoring Shall Be Provided By A 2 Times 7 Point Led Level Meter (Peak, +6, +3, 0, -3, -10, -20Db). Technical Performance Frequency Response: Pm 0.5Db From 20Hz To 20Khz (Referenced To Nominal Output Level @ 1Khz). Total Harmonic Distortion (Thd): 0.01% @ +8Dbu (20Hz To 20Khz), Gain Knob: Min 0.003% @ +18Dbu (1Khz), Gain Knob: Min Hum & Noise: Equivalent Input Noise Of -128 Dbu (Mono Input Channel, Rs: 150Ω, Gain Knob: Max) Crosstalk: -88Db @ 1Khz. Mechanical And Electrical Specifications Chassis: The Unit Shall Be Housed In A Robust, Impact-Resistant, Powder-Coated Metal Chassis. Power Supply: External Ac Adapter: Pa-130 (120V 60Hz) Or Mu18 (100-240V 50/60Hz) Or Equivalent. Power Consumption Shall Be Approximately 12W. , Indoor Wi-Fi6 Access Point General System Requirements Type: The Unit Shall Be A High-Performance, High-Speed 11Ax (Wi-Fi 6) Indoor Dual-Band Ceiling-Mounted Wireless Access Point (Ap). Standard Support: The Wireless Access Point (Ap) Shall Strictly Adhere To The Ieee 802.11Ax (Wi-Fi 6) Standard. Radio Configuration: The Unit Must Be A High-Power Industrial Ceiling-Mounted Ap Featuring 2X2 Mimo Technology For Both 2.4 Ghz And 5 Ghz Bands. Performance: The System Must Provide A Combined Wireless Data Rate Of Up To 3 Gbps To Support High-Speed Applications Such As 4K/8K Streaming And Vr/Ar. User Capacity: The System Shall Support A High Density Of Users, Accommodating Up To 128 Concurrent Users (Max 64 Users Per Band). Advanced Features: The Ap Shall Support Multi-User Mimo (Mu-Mimo), Orthogonal Frequency Division Multiple Access (Ofdma), Bss Color Bit, And Dynamic Cca-Sd For Improved Interference Management. Hardware Specifications Chipset: The Ap Shall Be Equipped With A High-Performance 4-Core Qualcomm Chipset. Ram: 512Mb Ddr3. Antenna: Integrated Internal 4X4Dbi Dual-Band Mimo Antennas. Combined Rate: A Concurrent Wireless Rate Of Up To 3000 Mbps. Physical Interfaces: 1 X 10/100/1000Mbps Wan/Poe Port. 1 X 10/100/1000Mbps Lan Port. 1 X Reset Button. Provision For A Dc2.0 12V 1.5A Power Connector. Support For Power Over Ethernet (Poe) Following Ieee 802.3Af/802.3At Standards. Thermal Management: The Unit Shall Feature A Heat Sink With A Snap-On Structure And Special Surface Coating To Optimize Heat Dissipation. Indicators: Led Status Lights For Power, Cloud Connection, Lan Speed, 2.4Ghz Status, And 5.0Ghz Status. Audio & Network Management Quality Of Service: Must Support Wmm (Wireless Multimedia Prioritization). Roaming: Support For Seamless Roaming To Ensure Uninterrupted Connectivity For Mobile Clients. Deployment: Flexible Deployment Options Including Standalone Mode, Mobile App Management, And Zero Touch Provisioning (Ztp). Network Management: Support For Vlan Settings, Cloud Access (In Gateway Mode), And System Logging. Management: Support For Remote Configuration And Management. Maintenance: Features For Backup/Restore Configuration, Factory Reset, Scheduled Reboots, And Lifetime Firmware Upgrades. Security Requirements Encryption: Must Support Wi-Fi Protected Access 3 (Wpa3) And Wired Equivalent Privacy (Wep) 64-Bit, 128-Bit, And 156-Bit. Access Control: Integrated Mac Address Filtering And Wireless Access Control To Identify Authorized Devices. Management Security: Secure Socket Layer (Ssl) For Remote Management Login And The Ability To Block Ssid Broadcasting. Environmental & Reliability Operating Limits: Working Temperature: -10°C To 55°C. Storage Temperature: -40°C To 70°C. Humidity: 5% To 95% Non-Condensing. Protection: Esd: Air ±8K, Touch 6K. Electrical Surge: Common Mode 2K, Differential Mode 1K. Power Efficiency: Maximum Power Consumption Shall Not Exceed 16 Watts. Oem Warranty And Support Local Presence: The Original Equipment Manufacturer (Oem) Must Have An Authorized Service Center Or Registered Office In Madhya Pradesh (Proof Of Gst/Msme/Registration Required With Bid). Warranty: A 2-Year On-Site Hardware Replacement Warranty Is Required, With New Hardware Provided Within 12 Hours Of A Call Lock (No Refurbished Or Repaired Products). Technical Support: On-Site Support Must Be Available Within 6 Hours Of A Request. Future Warranty & Support: Oem Must Have Warranty And Support Pack Purchase Option Before Expiry Of Warranty Period For Next Years. Service Availability: The Oem Must Provide A 24X7 1800-Series Toll-Free Number With Support Available In The Local Hindi Language. Product Life Cycle: The Quoted Product Must Have A Life Cycle Of No Less Than 5 Years From The Date Of Supply, Including Lifetime Free Firmware And Technical Assistance. Certifications: The Product Must Be Ce, Fcc, Rohs, Iec 15408 And Iso 9001. Certified. Bidder Must Have To Submit Compliance On Oem Letter Head Along With Maf. , Network Wall Mount Rack Must Have To Supply And Installation Of 15U 500X550 Network Wall Mount Rack With Glass Door And Lock With Hardware, 6 Socket Industrial Pdu 15Amp With Mcb, Cable Manager, Fan, Hardware And Etc. , Goosneck Mic Cable, Speaker Cable In Meter, Installation And Accessories Complete Job Work With Required Cables, Frpvc Conduit, Accessories, Fitting, Installation And Etc.
Contract Date: Jun 09, 2026 Contract Value : 2.02 Lakh
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
10.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 46.99 Lakh
Government Departments No of Bidders 12
Andhra Pradesh View Result →
13.
Chemicals and Fertilizers #10904912 AOC
Bids Are Invited For Custom Bid For Services - Virtual Servers Os - Windows Server License Included 4Vcpu, 16Gb Ram, 500Gb Storage Ssd, Gpu Enable Instance - Min16gb Gpu Memory,3000 Iops, Server For Iis Or Web Adaptor For Arcgis Portal, Hosting, Arcgis Pro Advance , Custom Bid For Services - Virtual Servers - Os - Windows Server (License Included) 4Vcpu, 32Gb Ram, 500Gb Storage Ssd, 3000 Iops, Server For Arcgis Enterprise Portal , Custom Bid For Services - Virtual Servers Os - Windows Server (License Included) 4Vcpu, 32Gb Ram, 500Gb Storage Ssd, 3000 Iops, Server For Arcgis Enterprise Server Advanced , Custom Bid For Services - Virtual Servers Os - Windows Server (License Included) 4Vcpu, 32Gb Ram, 500 Gb Storage, 3000 Iops Server For Ms Sql Server 2019(Sql Licence Provided By Bgcl), Arcgis Datastore Relational Tile Cache , Custom Bid For Services - Database Service For Aurora Postgresql And Amazon Rds Instance (Db T4g Large),100 Gb Backup Storage, Including Automated Backup And Patching And High Availability , Custom Bid For Services - Application Load Balancer , Custom Bid For Services - Web Application Firewall (Waf) , Custom Bid For Services - Client Vpn (1Qty) , Custom Bid For Services - Route 53 Domain Name System , Custom Bid For Services - Provisioning Of S3 Object Storage Of 1Tb , Custom Bid For Services - Network Address Translation (Nat) Gateway , Custom Bid For Services - Public Ipv4 Address: 2 For Web Server And 4 Privet Ipv4 Address , Custom Bid For Services - Cloud Watch Monitor Services , Custom Bid For Services - Provisioning Of Network Services (Considering 300Gb / Month Of Data Transfer I E 150Gb / Month Of Upload And 150Gb / Month Of Download) , Custom Bid For Services - Daily Image (Ami) Backups With A Retention Period Of 7 Days As Dr Rto Less Than Or Equal To 4 Hours And Rpo Less Than Or Equal To 2 Hours, After Restoring The Data We Have Configure The Connectivity , Custom Bid For Services - Aws Key Management Service , Custom Bid For Services - Object Storage Upgrade Per 10 Gb Per Month , Custom Bid For Services - Ssd Storage Upgrade 10 Gb Per Month, Rds And Each Ec2 Storage 10 Gb Per Month , Custom Bid For Services - Installation, Migration, Integration, Configuration, Testing, Commissioning, Hands On Training (Certification Minimum 3 Person) Of Cloud Infrastructure , Custom Bid For Services - 24*7*365 Managed Cloud Services Including Monitoring, Patching, Backup, Security Sla Management
Contract Date: Ref. Documents Contract Value : 58.63 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
14.
Coal and Mines #10889672 AOC
Bids Are invited for Fore Court Controller Fcc - Forecourt Controller Integrates With Flow Meter And Mobile Dispensing Unit, Integrates With Rfid Tags And Container Rings With All Configurations Of Rfid Readers Including Nozzle Reader, In-Built Battery Backup Of 15 Minutes, Mounted Inside The Mobile Bowser Simple Enclosure. The Enclosure Should Be Rugged To Prevent The Effects Of Vibration Of The Vehicle Movement From Adversely Affecting The Functioning Of The Electronics And Connected Devices. , Wireless Gateway Terminal - Type-Rf And Safe Area Mounted. Communication Between Nozzle Reader And Rfid Controller-Iec By Iso Compliant. Installation-Should Be Installed In Such A Way That All Nozzle Readers Are Able To Communicate With The Same Wireless Equipment. Should Be Stable Operation In Noisy Or Busy Environment. Data Security-The Wireless Communication Should Been Crypted Using Aes 128Bit. Should Communicate With Fcc. Operating Voltage-Suitable To Operate With Ac Power Available At The Ro. Ip Rating-Ip54. Remote Diagnostics-Should Be Accessed Over Web For Diagnostics, Trouble Shooting And Upgrade Task E.G, Software Upgrade, Battery Check, Communication Check Etc. Communication Channels-Should Employ Multiple Channel Frequency Networks To Enable Fast Switching Of The Channels To Ensure Uninterrupted Communication With Station Automation System. Rf Frequency Bands To Meet Regional Frequency Allocation Regulations. , Industrial Router - Router Cum Modem To Support All Gsm Communication Network Available In India Including Having Features Of Volte Compatibility. In Case Of No Communication, Router Should Have Inbuilt Intelligence To Continuously Ping Mcl Server Without Going To Sleep Mode , Rfid Nozzle Reader Peso Approved - Type-Rf. Communication Between Rf Vehicle Tag And Nozzle Reader-Iec By Iso Compliant By Lf. Communication Between Nozzle Reader And Rfid Controller-Iec By Iso Compliant By Ieee. Security-Once Mounted On The Nozzle And Activated, It Should Be Deacti
Contract Date: Ref. Documents Contract Value : 10.86 Lakh
Boards / Undertakings / PSU No of Bidders 1
15.
Road Transport and Highways #10855842 AOC
Bids Are invited for TITLE 1 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF CAT6 UTP Cable 23 AWG Solid Copper 4 Pair UTP PVC FRLS for Data Cabling in mtrs , TITLE 2 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Information Outlet and Faceplate 2 Port 1 Port Modular Faceplate with Shutter Workstation and Telephone Points , TITLE 3 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Back Box PVC or Metal Wall Mount suitable for Modular Faceplate All Data and Voice Points , TITLE 4 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF CAT6 I O Keystone Jack Wall Mount suitable for Jack All Data & Voice Points , TITLE 5 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Patch Panel 24 Port CAT6 24Port Loaded Patch Panel with Cable Management Bar Network Rack Per Floor , TITLE 6 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Patch Cord Data 1m Factory Molded Certified CAT6 Workstation to IO and Rack Termination , TITLE 7 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Patch Cord Data 2m Factory Molded Certified CAT6 Workstation to IO and Rack Termination , TITLE 8 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Fiber Cable 6 Core Multi Mode Armoured Multi Mode OM3 MM Armoured Fiber Cable Backbone Between Floors Racks , TITLE 9 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF LIU Fiber Termination Box 6 Port with Pigtails Rack End Termination 2X3 , TITLE 10 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Fiber Patch Cord Data 3 Mtr Duplex Multimode Fiber Patch Cord LC to LC Workstation to IO and Rack Termination , TITLE 11 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF SFP Moudule Duplex Multimode SFP Rack Termination to Rack Termination , TITLE 12 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Smart Managed Switch L2 24 Port Gigabit 24 x 1G RJ45 4 x SFP VLAN QoS SNMP Per Floor Distribution Switch 2X6 , TITLE 13 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Smart Managed Switch L2 48 Port Gigabit 48 x 1G RJ45 4 x SFP VLAN QoS SNMP Per Floor Distribution Switch 1X6 , TITLE 14 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 16Port Gigabit Unmanaged PoE Switch 16 x 1G RJ45 , TITLE 15 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Network Rack 27U Floor Mount with Power Distribution Unit PDU 27U 800mm Depth Glass Door Cooling Fan PDU Floor Department Network Room , TITLE 16 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Accessories N Consumables horizontal Cable Managers As per installation requirement , TITLE 17 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Accessories NConsumables 1U horizontal Cable Tray As per installation requirement , TITLE 18 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF One Time Installtion As per installation requirement , TITLE 19 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Ubiquiti UDM Machine Pro Controller 10G Cloud Gateway with 100 UniFi device 1000 client support 1.3 inch touchscreen Server Room Wifi Controller , TITLE 20 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Ubiquiti UniFi 6 Long Range Access Point PoE Adapter not Included LR US High Rage Wifi , TITLE 21 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Ubiquiti UniFi U6 Access Point PoE Adapter not Included U6 Plus Low Range Wifi , TITLE 22 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF One Time Installtion As per installation requirement , TITLE 23 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 2MP IP Camera dome for indoor , TITLE 24 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF NVR 32 Channel Server Control Room , TITLE 25 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Hard Disk Sata 10 TB HDD Expandable H265 60 Days Backup Server Control Room , TITLE 26 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 4K HDMI 20 Meter Cable HDMI 2pnt0 V Cable With Ethernet 3D Supported TV Projector HDMI Cable , TITLE 27 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 4x1 HDMI Switcher with Audio HDMI Switch 4 in 1 Out 4K 60Hz Splitter Bi Directional 2 Input 1 Output Support HDMI Cable , TITLE 28 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF One Time Installtion Labour Installtion Labels Ferrules Tags Services , TITLE 29 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF UPS System Waveform Sine Wave Capacity 40000 VA Input Phase 3 Phase Output Phase 3 Phase Warranty 1 Year 40 kVA 30Min Backup Each Network Rack Server Room , TITLE 30 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF Capacity 12V 65AHBattery with Warranty 24 Months by MFG Backup Time Approx 30 mins on Full Load Pure Sine Wave SMF Batteries for 30Min Backup Each Network Rack Server Room , TITLE 31 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF MS Open Battery Rack with Interlinks Accessories Each Network Rack Server Room , TITLE 32 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF DC Breaker and Interlinks Accessories Each Network Rack Server Room , TITLE 33 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 3 core copper cable 25 sqmm FRLS with accessories in mtrs , TITLE 34 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF 2 core copper cable 16 sqmm FRLS with accessories in mtrs , TITLE 35 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF MCCB 100 AMP rated current and 415 V C voltage , TITLE 36 - SUPPLY INSTALLATION TESTING AND COMMISSIONING OF supply and one time installation and comissioning Total Quantity : 45107
Contract Date: Ref. Documents Contract Value : 2.22 Crore
Government Departments No of Bidders 4
Maharashtra View Result →
16.
Defence #10845268 AOC
Tender For Renewal Replacement Of Furniture Against Surveyed Furniture Items At Naval Station Karanja; 1 Supply, Installation and testing of VPN Firewall (Sophos) with 1 year enterprise Guard License with Ethernet interfaces (fixed)-4GbE copper , I/O ports-2 x USB 2.0,1 x Micro-USB, 1 x COM (RJ45) with COMPUTER including monitor of 32 inch (4K) having the following specifications: (a) Processor: INTEL i7 processor, (b) RAM 16 GB RAM, (c) Hard Disk: 1TB, (d) Keyboard and Mouse (e) LAN port (f) Inbuilt software: Anti virus softwareand Windows 11 or better (g) All SCADA System related softwares like FT View, KEP Server SQL Management Studio etc all as directed by Engineer-in-Charge. Make: DELL, HP, Samsung, Lenovo 2 Supply, Installation and testing of new PLC , Digital Inputs, Digital Outputs, Analog Inputs, Serial Communication RS232/ RS485 x 1, Ethernet Port x 1 and re-wiring of the exisiting panel with respect to the required Inputs & Outputs including dismantling of unserviceable PLC complete .Make: Mitsubishi/ Delta/ Honeywell. 3 Supply, Installation,testing and Comissioning of GPRS Modem Dual SIM redundancy for persistent 2G/3G/4G cellular network connections having features of IP sec/Open VPN /GRE /L2TP/PPTP/DMVPN with 1 Ethernet Port, 1 RS232/RS485 Port complete all as specified. Make: Robustel, Maestro, Teltonika 4 S&F for PVC insulated and sheathed armoured copper cable of size 1.5 Sqmm 4 core fixedon wall/ RCC tank/surface etc complete all as specified and directed by Engr-in charge . Make: Polycab / KEI / Havells. 5 Supply, Installation, testing and comissioning of factory talk view SE station license for local (single station) applications where all components run on one computer. Applications can be configured to local or to work with other factory talk products like factory talk historian SE, networked scope including supply, Installation, testing and comissioning of OPC server for unlimited tags with MODBUSTCP/equivalent driver having provision for IOT gateway to exchange data between the PLC based panels and the system complete all specified.Make: Rockwell Automation/CIMCON/SCHNEIDER ELECTRIC. 6 Programming, Comissioningand testing(On-Site) of the existing PLC based automation panels, OPC tags creation, tags creation for new panels, screen development, Object linking, tag linking with OPC, data validation on SCADA server as per the instructions of Engineer-in-Charge. 7 Supply, Installation, testing and comissining of Ultrasonic Level Sensor range from 0 to 8 meters all as specified and directed by Engineer-in-Charge.Make: Banner/ SIEMENS/ ENDRESS HAUSER. 8 S&F in replacement ofCast iron Butterfly valve along with actuator assembly complete of size 200 mm dia, PN 10 with stainless steel shaft, operating angle 90° complete all as specified and directed by Engineer-in-Charge. Make: ZOLOTO/ Kirloskar/ Venus/L&T. 9 S&F in replacement ofCast iron Butterfly valve along with actuator assembly complete of size 150 mm dia, PN 10 with stainless steel shaft, operating angle 90° complete all as specified and directed by Engineer-in-Charge. Make: ZOLOTO/ Kirloskar/ Venus/L&T. 10 S&F in replacement of hand wheel for actuator suitable for 100 to 200 mm dia butterfly Valve . Make : Ritetork/ Emtork/Venus/L&T
Contract Date: May 05, 2026 Contract Value : 15.35 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
17.
Petroleum and Natural Gas #10788141 Price Bid
Procurement Of Prepaid Smart (G 1.6) Domestic Gas Meters For Cgd Projects , Supply Of Natural Gas Prepaid Smart (G 1.6) Domestic Gas Meter (With Integrated Amr And Internal Valve) For Domestic Consumers Suitable For Prepaid Smart Metering System As Per The Technical Specification. , G-1.6 Prepaid Smart Gas Meter ( Nb - Iot/Lora/ Or Any Other Two Way Communication Technology ) , Comprehensive Operational And Maintenance Services Of Smart Metering Infrastructurei.E. Recurring Monthly Service Charges Which Shall Include But Not Limited To A) Smart Gas Meter Interfacing And Configuration. B) Operational And Maintenance Of Web Application/Dashboard For Client Monitoring /Automatic Metering & Data Management System. C) Cloud Server , Data Hosting And Data Transmission To Clients Billing Server Charges. D) Network Service Provider And Components I.E. Nb-Iot/Lora/Gsm Sim And Other Associated Charges. E) Payment Gateway Integration/Mobile Apps Charges/ Facilitate Customers To Top Up Their Accounts Through Registered Pay Facilities, Credit/Debit Cards Via Mobile/Online Transactions. F) Smart Meter Integration With Sap And Scada. G) Customer Alerts Via Sms And Email. H) Comprehensive Maintenance And Upkeep Of Metering System Components. I) Charges For Other Compliances In Line With Scope Of Supply, Technical Specifications And Scope Of Work. , 1St Year Service Charges ( Per Month Charges) , 2Nd Year Service Charges ( Per Month Charges) , 3Rd Year Service Charges ( Per Month Charges) , 4Th Year Service Charges ( Per Month Charges) , 5Th Year Service Charges ( Per Month Charges)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Uttar Pradesh View Result →
18.
Rural Development #10766596 Price Bid
Provide Provide And Install Cc Tv Camera At Jambhiwali Grampanchayat Tal Khalapur Dist Raigad , Supply And Install Cc Tv Camera , Ip Bullet Camera • 1/2.7” 4Mppscmosimagesensor • 20Fps@1080P(1920×1080) • H.265+/H.265Dual-Streamencoding • 3.6Mmlens(2.8Mmoptional) • Irrangeof20mtrs, Ip67,Poe • Colourfull Night Recording , • Full Hd 2 Mp Bullet Camera, • H.265+/H.265Dual-Streamencoding Dwdr, Day/Night(Icr), 3D-Dnr • 3.6Mm Lens, Ir 20Mtr, • Ir Light, Day/Night, • Motion Sensor, • Weatherproof Ip66 , Ip Bullet Camera • 1/2.7”4Mp Cmos Image Sensor • 20Fps@ 1080P (2592×1520) • H.265+/H.265Dual-Streamencoding • Dwdr, Day/Night(Icr), 3D-Dnr,Roi,Awb,Agc,Blc,Hlc • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom • Ir Range Of30mtrs,Ip67,Poe , Full Hd 2 Mp Bullet Camera, • 20Fps@ 1080P • H.265+/H.265Dual-Streamencoding Dwdr, Day/Night(Icr), 3D-Dnr • Ir 30Mtr, Ir Light, Day/Night, • 2.8-12 Mm Lenc • Digital Zoom • Optical Zoom Weatherproof Ip66 , Ip Bullet Camera • 1/2.7”2Mppscmosimagesensor • 20Fps@1080P(1920×1080) • H.265+/H.265Dual-Streamencoding • 3.6Mmlens(2.8Mmoptional) • Irrangeof 20Mtrs, Ip67,Poe Colourfull Night Recording , Full Hd 5 Mp Bullet Camera, • 20Fps@ 1080P (2592×1520) • H.265+/H.265Dual-Streamencoding Dwdr, Day/Night(Icr), 3D-Dnr • Ir 30Mtr, Ir Light, Day/Night, • 2.8-12 Mm Lenc • Digital Zoom • Optical Zoom •Weatherproof Ip66 , • Full Hd 5 Mp Bullet Camera, • H.265+/H.265Dual-Streamencoding Dwdr, Day/Night(Icr), 3D-Dnr • 3.6Mm Lens, Ir 20Mtr, • Ir Light, Day/Night, • Motion Sensor, Weatherproof Ip66 , Ip Bullet Camera 1/2.7” 4Mp Ps Cmos Image Sensor • 20Fps@1080P(2592×1520) • H.265+/ H.265 Dual-Stream Encoding • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom • Ir Range Of 50 Mtrs, Ip67, Poe , Ip Bullet Camera 1/2.7” 2 Mp Ps Cmos Image Sensor • 20Fps@1080P(2592×1520) • H.265+/ H.265 Dual-Stream Encoding • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom • Ir Range Of 50 Mtrs, Ip67, Poe , Ip Bullet Camera • 1/2.7”2Mp Cmos Image Sensor • 20Fps@ 1080P (2592×1520) • H.265+/H.265Dual-Streamencoding • Dwdr, Day/Night(Icr), 3D-Dnr,Roi,Awb,Agc,Blc,Hlc • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom Ir Range Of30mtrs,Ip67,Poe , Dvr • 4Ch 5Mp Full Hd • Insta On Cloud • Up To 8Mp Resolutionpreview And Playback • 1Ch Audio In • Hdmi,Vga, 1 Sata Port • Support Multi-Brand Hd Cameras , • Nvr • Support Up To 1Ch@8Mp/16Ch@1080Pdecoding • H.265/H.264Dualcodecdecoding • Up To 8Mp Resolutionpreview And Playback • Max 100 Mbps Incomingbandwidth • Support 1 Sata Hdds Up To 6Tb,2Usbports(2.0) • Hdmi/Vga Simultaneous Video Output • Support Multi-Brand Network Cameras • Onvifversion2.4Conformance , Dvr • 4Ch 2Mp Full Hd • Insta On Cloud • Up To 8Mp Resolutionpreview And Playback • 1Ch Audio In • Hdmi,Vga, 1 Sata Port • Support Multi-Brand Hd Cameras , Dvr • 16Ch 5Mp Full Hd • Insta On Cloud • 1Ch Audio In • 2 Sata Port • Up To 8Mp Resolutionpreview And Playback • Support Multi-Brand Hd Cameras Hdmi,Vga , Dvr • 16Ch 2 Mp Full Hd • Insta On Cloud • 1Ch Audio In • 2 Sata Port • Up To 8Mp Resolutionpreview And Playback • Support Multi-Brand Hd Cameras Hdmi,Vga , • Nvr • Support Up To 1Ch@8Mp/4Ch@1080Pdecoding • H.265/H.264Dualcodecdecoding • Up To 8Mp Resolutionpreview And Playback • Max40mbpsincomingbandwidth • Support 1 Sata Hdds Up To 6Tb,2Usbports(2.0) • Onvifversion2.4Conformance , • Nvr • Support Up To 1Ch@8Mp/8Ch@1080Pdecoding • H.265/H.264Dualcodecdecoding • Up To 8Mp Resolutionpreview And Playback • Max40mbpsincomingbandwidth • Support 1 Sata Hdds Up To 6Tb,2Usbports(2.0) • Onvif Version2.4 Conformance , • Poe Switch • Poeport:4,10/100Mbpsrj45ports ,Uplinkport:2,100Methernet Port • Providesupto30wattsperpoeport • Plug-And-Play Installation • Ieee 802.3At And Ieee 802.3Af Powerover Ethernet(Poe)Compliant • Networkprotocol:Ieee802.3,802.3U,802.3X,802.3Af • 250 Mtr Range , • Poe Switch 2Gigabit Ethernet Port • Poeport:8,10/100 Mbpsrj45ports ,Uplinkport:2,Gigabit Ethernet Port • Provides Up To 30 Watts Per Poe Port • Plug-And-Play Installation • Ieee 802.3At And Ieee 802.3Af Powerover Ethernet(Poe)Compliant • Networkprotocol:Ieee802.3,802.3U,802.3X,802.3Af • 250 Mtr Range , • 5Amp Smps • Capable To Sending Power Upto 150 Mtr Range , • 10 Amp Smps • Capable To Sending Power Upto 150 Mtr Range , • Gigabitswitch • Auto-Negotiates Port Speed To 10Mbps,100Mbps,Or1000mbps • Plug& Playinstallation • Uses 802.3Az Energy Efficientethernet To Reduce Power Usageautomatically Without Sacrificingperformance , 4Tb[4000 Gb] Special Cctv Surveillancehdd Features-All Frame 4K,Supports Up To 64Cameras Enhanced Workload Rating Designed For24*7Systems[Not Computerhdd] , 2Tb[2000 Gb] Special Cctv Surveillancehdd Features-All Frame 4K,Supports Up To 64Cameras Enhanced Workload Rating Designed For24*7Systems[Not Computerhdd] , 2-6-Core Optical Fiber + Labor Charges , Media Converter , Cctv Cable 1+3, 2 Power, 1 Video Cable , Nvrconfiguration , Fitting I/O,Mounting Cameras— Nos Nvrconfiguration, Cctvvideocrimping-Nos Mobile,Pc,Routerconfiguration,4”*4”I/O Box With F Aceplate Ties— , Wireless Access Point Device , Pure Copper Cat-6 Cable Includinglabour Charges +Ties+Huks , Wireless Access Point Configuration , 4Unetwork Rack , 2 /3 Urack , Iball/Zebronicups600va , Screen To Monitor Cctv 18.5” , Fiber Splicing Charges , Dvr Nvrrackinstallation , Housing To Protect Outdoor Ip Cameras , 12-15Ft Metal Pole With Erection , 2 Hdmi Hdtv Screen32” , Dvr Configuration , Wire Rope , Wireless Repeater , Router 600Mbps , Cisco 1800 Router , Two In One Gateway Router , 5Mtr Hdmi Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
19.
Rural Development #10766588 Price Bid
Provide Provide And Install Cc Tv Camera At Isambe Grampanchayat Tal Khalapur Dist Raigad , Supply And Install Cc Tv Camera , Ip Bullet Camera • 1 / 2.7” 4Mppscmosimagesensor • 20Fps@1080P ( 1920×1080 ) • H.265+ / H.265Dual-Streamencoding • 3.6Mmlens ( 2.8Mmoptional ) • Irrangeof20mtrs, Ip67, Poe • Colourfull Night Recording , • Full Hd 2 Mp Bullet Camera, • H.265+ / H.265Dual-Streamencoding Dwdr, Day / Night ( Icr ) , 3D-Dnr • 3.6Mm Lens, Ir 20Mtr, • Ir Light, Day / Night, • Motion Sensor, • Weatherproof Ip66 , Ip Bullet Camera • 1 / 2.7”4Mp Cmos Image Sensor • 20Fps@ 1080P ( 2592×1520 ) • H.265+ / H.265Dual-Streamencoding • Dwdr, Day / Night ( Icr ) , 3D-Dnr, Roi, Awb, Agc, Blc, Hlc • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom • Ir Range Of30mtrs, Ip67, Poe , Full Hd 2 Mp Bullet Camera, • 20Fps@ 1080P • H.265+ / H.265Dual-Streamencoding Dwdr, Day / Night ( Icr ) , 3D-Dnr • Ir 30Mtr, Ir Light, Day / Night, • 2.8-12 Mm Lenc • Digital Zoom • Optical Zoom Weatherproof Ip66 , Ip Bullet Camera • 1 / 2.7”2Mppscmosimagesensor • 20Fps@1080P ( 1920×1080 ) • H.265+ / H.265Dual-Streamencoding • 3.6Mmlens ( 2.8Mmoptional ) • Irrangeof 20Mtrs, Ip67, Poe Colourfull Night Recording , Full Hd 5 Mp Bullet Camera, • 20Fps@ 1080P ( 2592×1520 ) • H.265+ / H.265Dual-Streamencoding Dwdr, Day / Night ( Icr ) , 3D-Dnr • Ir 30Mtr, Ir Light, Day / Night, • 2.8-12 Mm Lenc • Digital Zoom • Optical Zoom •Weatherproof Ip66 , • Full Hd 5 Mp Bullet Camera, • H.265+ / H.265Dual-Streamencoding Dwdr, Day / Night ( Icr ) , 3D-Dnr • 3.6Mm Lens, Ir 20Mtr, • Ir Light, Day / Night, • Motion Sensor, Weatherproof Ip66 , Ip Bullet Camera 1 / 2.7” 4Mp Ps Cmos Image Sensor • 20Fps@1080P ( 2592×1520 ) • H.265+ / H.265 Dual-Stream Encoding • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom • Ir Range Of 50 Mtrs, Ip67, Poe , Ip Bullet Camera 1 / 2.7” 2 Mp Ps Cmos Image Sensor • 20Fps@1080P ( 2592×1520 ) • H.265+ / H.265 Dual-Stream Encoding • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom • Ir Range Of 50 Mtrs, Ip67, Poe , Ip Bullet Camera • 1 / 2.7”2Mp Cmos Image Sensor • 20Fps@ 1080P ( 2592×1520 ) • H.265+ / H.265Dual-Streamencoding • Dwdr, Day / Night ( Icr ) , 3D-Dnr, Roi, Awb, Agc, Blc, Hlc • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom Ir Range Of30mtrs, Ip67, Poe , Dvr • 4Ch 5Mp Full Hd • Insta On Cloud • Up To 8Mp Resolutionpreview And Playback • 1Ch Audio In • Hdmi, Vga, 1 Sata Port • Support Multi-Brand Hd Cameras , • Nvr • Support Up To 1Ch@8Mp / 16Ch@1080Pdecoding • H.265 / H.264Dualcodecdecoding • Up To 8Mp Resolutionpreview And Playback • Max 100 Mbps Incomingbandwidth • Support 1 Sata Hdds Up To 6Tb, 2Usbports ( 2.0 ) • Hdmi / Vga Simultaneous Video Output • Support Multi-Brand Network Cameras • Onvifversion2.4Conformance , Dvr • 4Ch 2Mp Full Hd • Insta On Cloud • Up To 8Mp Resolutionpreview And Playback • 1Ch Audio In • Hdmi, Vga, 1 Sata Port • Support Multi-Brand Hd Cameras , Dvr • 16Ch 5Mp Full Hd • Insta On Cloud • 1Ch Audio In • 2 Sata Port • Up To 8Mp Resolutionpreview And Playback • Support Multi-Brand Hd Cameras Hdmi, Vga , Dvr • 16Ch 2 Mp Full Hd • Insta On Cloud • 1Ch Audio In • 2 Sata Port • Up To 8Mp Resolutionpreview And Playback • Support Multi-Brand Hd Cameras Hdmi, Vga , • Nvr • Support Up To 1Ch@8Mp / 4Ch@1080Pdecoding • H.265 / H.264Dualcodecdecoding • Up To 8Mp Resolutionpreview And Playback • Max40mbpsincomingbandwidth • Support 1 Sata Hdds Up To 6Tb, 2Usbports ( 2.0 ) • Onvifversion2.4Conformance , • Nvr • Support Up To 1Ch@8Mp / 8Ch@1080Pdecoding • H.265 / H.264Dualcodecdecoding • Up To 8Mp Resolutionpreview And Playback • Max40mbpsincomingbandwidth • Support 1 Sata Hdds Up To 6Tb, 2Usbports ( 2.0 ) • Onvif Version2.4 Conformance , • Poe Switch • Poeport:4, 10 / 100Mbpsrj45ports , Uplinkport:2, 100Methernet Port • Providesupto30wattsperpoeport • Plug-And-Play Installation • Ieee 802.3At And Ieee 802.3Af Powerover Ethernet ( Poe ) Compliant • Networkprotocol:Ieee802.3, 802.3U, 802.3X, 802.3Af • 250 Mtr Range , • Poe Switch 2Gigabit Ethernet Port • Poeport:8, 10 / 100 Mbpsrj45ports , Uplinkport:2, Gigabit Ethernet Port • Provides Up To 30 Watts Per Poe Port • Plug-And-Play Installation • Ieee 802.3At And Ieee 802.3Af Powerover Ethernet ( Poe ) Compliant • Networkprotocol:Ieee802.3, 802.3U, 802.3X, 802.3Af • 250 Mtr Range , • 5Amp Smps • Capable To Sending Power Upto 150 Mtr Range , • 10 Amp Smps • Capable To Sending Power Upto 150 Mtr Range , • Gigabitswitch • Auto-Negotiates Port Speed To 10Mbps, 100Mbps, Or1000mbps • Plug& Playinstallation • Uses 802.3Az Energy Efficientethernet To Reduce Power Usageautomatically Without Sacrificingperformance , 4Tb [ 4000 Gb ] Special Cctv Surveillancehdd Features-All Frame 4K, Supports Up To 64Cameras Enhanced Workload Rating Designed For24*7Systems [ Not Computerhdd ] , 2Tb [ 2000 Gb ] Special Cctv Surveillancehdd Features-All Frame 4K, Supports Up To 64Cameras Enhanced Workload Rating Designed For24*7Systems [ Not Computerhdd ] , 2-6-Core Optical Fiber + Labor Charges , Media Converter , Cctv Cable 1+3, 2 Power, 1 Video Cable , Nvrconfiguration , Fitting I / O, Mounting Cameras— Nos Nvrconfiguration, Cctvvideocrimping-Nos Mobile, Pc, Routerconfiguration, 4”*4”I / O Box With F Aceplate Ties— , Wireless Access Point Device , Pure Copper Cat-6 Cable Includinglabour Charges +Ties+Huks , Wireless Access Point Configuration , 4Unetwork Rack , 2 / 3 Urack , Iball / Zebronicups600va , Screen To Monitor Cctv 18.5” , Fiber Splicing Charges , Dvr Nvrrackinstallation , Housing To Protect Outdoor Ip Cameras , 12-15Ft Metal Pole With Erection , 2 Hdmi Hdtv Screen32” , Dvr Configuration , Wire Rope , Wireless Repeater , Router 600Mbps , Cisco 1800 Router , Two In One Gateway Router , 5Mtr Hdmi Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
20.
Educational and Research Institute #10734365 AOC
Notice Inviting Etender For Procurement Of Equipment, Instruments, Machineries, Tools Charts Etc. Related To Laboratories And Workshop Of Engineering Institute For Junior Executives, Dalalpukur, Howrah-711104-1 Dead Weight Pressure Gauge Tester • Bourdon Tube Pressure Gauge As Manometer • Manometer With Transparent Scale • Manufactured From Corrosion Resistant Materials • Components Arranged On Base Plate. • Set Of Weights • Medium For Transmitting Pressure: Hydraulic • Capacity Of 25Kg / Cm2 • The System Is Nickel Chrome • The Weights Are Zink Iron ) 2 Cut Section Model Of Hermetically Sealed Compressor 3 Universal Bevel Protractor ( Accuracy: 0.01 Mm Material: Stainless Steel Diameter: 70 Mm Size: 300 Mm Type: Analog Graduation 5 Min Straightness .00016+ ( .00005Xl / 2 ) ) 4 Cut Section Model Of Lamont Boiler 5 Slip Gauge Set; Special Set ( M87 ) , Grade I, High Grade Steel, 9 Mm Wide & 30-35 Mm Long Cross Section. 6 Utm Machine ( Material:Ms Voltage:220 V Phase: Single Phase Capacity: 10 To 100 Ton Cross Travel: Up To 1000 Mm Weight: 1500 Kg ) 7 Mollier Chart Flex ( 40 × 30 ) 8 Teak Wood; Wood For Pattern Shop Size: 2×1×6 9 Thermal Conductivity Of Metal Rod; • Frame: Made Of M.S. Square Tubes & Sheets, Welded & Powder Coated • Optional Accessories: Rotameter For Water Flow Measurement • Electric Heater : Clamp Heater, Capacity 200 W, Supply 230 V Ac • Insulation Jacket: Made Of Mild Steel, Mild Steel Rod Is Insulated By Asbestos Powder • Diameter Of Metal Rod 25 Mm, Length Of Rod 300 Mm 10 Cut Section Model Of Screw Type Rotary Air Compressor 11.01 Chart Of Velox Boiler With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.02 Chart Of Mollier Diagram With Labelling ( Size: 23’’ X 36’’, Material: Pvc, With Roller ) 11.03 Chart Of T-T-T Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.04 Chart Of Utm Machine & Sample With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.05 Chart Of Torsion Testing Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.06 Chart Of Iron-Carbon Equilibrium Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.07 Chart Of Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.08 Chart Of Vernier Height Gauge With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.09 Chart Of Thread Measurement With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.10 Chart Of Gear Tooth Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.11 Chart Of Hermetically Sealed Compressor With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.12 Chart Of Domestic Refrigerator With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.13 Chart Of Full Pressure Engine Lubricating System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.14 Chart Of Constant Mesh Gear Box With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.15 Chart Of Synchromesh Gear Box With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.16 Chart Of Components Of A Chasis With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.17 Chart Of Knuckel Joint With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.18 Chart Of Intersection Of A Prism And Cone ( Size:30× 40, Material: Pvc, With Roller ) 11.19 Chart Of Projection Of A Straight Line In Different Quadrants ( Size:30× 40, Material: Pvc, With Roller ) 11.20 Chart Of Plummer Block - Details And Arrangement ( Size:30× 40, Material: Pvc, With Roller ) 11.21 Chart Of Centrifugal Pump With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.22 Chart Of Balanced Type Vane Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.23 Chart Of Bent Axis Piston Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.24 Chart Of Lathe Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.25 Chart Of Single Point Cutting Tool Geometry With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.26 Chart Of Screw Jack Assembly With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.27 Chart Of Cotter Joint Assembly And Design With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.28 Chart Of Vertical Drilling Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.29 Chart Of Shaper Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.30 Chart Of Safety On A Lathe Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.31 Chart Of Safety On A Milling Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.32 Chart Of Safety On A Shaper Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.33 Chart Of Safety In Carpentry Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.34 Chart Of Safety In Fitting Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.35 Chart Of General Precaution In Workshop ( Size:30× 40, Material: Pvc, With Roller ) 11.36 Chart Of Cnc Turning With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.37 Chart Of Elements Of Jigs ( Drill Bushes ) With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.38 Chart Of Tig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.39 Chart Of Mig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.40 Chart Of Engine Cooling System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 12 Digital Lab Trainer ( Bread Board Model ) ( Built-In Dc Regulated Power Supply; At Least 8 Logic Input Switches; At Least8 Output Led; Pulse Generator For Clock Frequency ; Patch Chords ) 13 Arduino Uno Board ( Atmega328 ) 14 Experimental Kit To Study Pam, Pwm And Ppm Modulation And Demodulation ( Pulse Generator With Variable Frequency And Amplitude, Pam Modulator And Demodulator, Pwm Modulator And Demodulator, Ppm Modulator And Demodulator ) 15 Ujt Trainer Kit With P.S. & Patch Cord 16 Led Colour Tv Demonstration Kit ( Display Type: Led, Hd: Screen Size: 24: Connectivity: Usb, Hdmi, Av: Test Points To Be Present Minimum 10 Nos.: Switched Faults To Be Provided: Product Tutorial Should Be Present ) 17 Microwave Oven Demonstration Trainer Kit ( Type: Solo: Capacity: 17 Ltr.: Control Type:Mechanical: All Circuits & Panels To Be Mounted On-Board: Test Points To Be Provided To Analyze Signals: Instruction Manual To Be Provided ) 18 Washing Machine Demonstration Trainer Kit ( Application: Lab Experiment: Semi-Automatic: Tank Capacity: 6.5 Kg: Block Diagram & Circuit Diagram To Be Mounted On The Lid: Test Points To Be Provided ) 19 Mobile Communication Trainer Kit To Study Various Signalling And Fault Insertion Techniques ( Gsm Handset Trainer Kit.  Operate Both On Windows And Linux Platform  Usb Interface For Communication  Best Suitable For Iot Gateway Application  External Connector To Interface With Any Microcontroller  Easy Understanding Of At Commands  Real Time Operation  Built In Network Status Led  Audio Interface Connector  Simple / Easy Operation  External Antenna  Application Module Relay Interface For Ac Device ( Optional ) ) 20 Trainer Kit For Mobilephone Set To Study Transmitter And Receiver Sections In Mobile Handset And Measure Frequency Band Signal ( Real Time Mobile Operation # Full Understanding Of Mobile Phone Working # Frequency Measurement And Band Verification # Provides Study Of All Sections In Mobile Phone # Tx / Rx Frequency Measurement # 3G / 4G Technology And Gmsk Signals # Gsm Data Rate # Detail Study Of User Interface Control Signals # Detail Study Of Sim Operation # Battery Identification And Charging Study  Switched Faults 21 Consumable ( 9V Battery, Cro Probe, Digital Ics ) 22 Cro ( 20 Mhz , Dual Trace, Dual Channel ) 23 Trainer Kit For Mobile Phone ( Features : The Experimental Kit Will Be Capable I ) To Study General Block Diagram Of A Mobile Phone. Ii ) To Study Mobile Transmission Section. Iii ) To Study Mobile Reception Section. Iv ) To Study Different Nos. Of Faults Provided With The Trainer. V ) To Study & Observe Voltages / Waveforms Of Each Test Points. Vi ) To Study Mobile Charging Circuits. Vii ) To Use Mobile Phone As Modem For Using At Commands As Given; A ) Sending Text Messages, Read / Delete Massages Etc. B ) Calling To A No, Reject / Accept The Incoming Calls Etc. C ) Gprs Related Commands. Study Of Bluetooth Technology & Connection With Other Bt Devices. Bluetooth Profiles : Bip, Bpp, Dunp, Ftp, Hid, Opp , Sap, A2dp, Pbap, Spp Etc. To Study General Idea Of Sim Card. ( Local Sim Card Must Be Inserted By The User At The Time Of Experiment ) . ) 24 Salt Bath Furnace For Heat Treatment ( • Resistance Heating ( Element ) • Operating Temp.: Up To 1200°C • Digital Temp. Controller ( Pid ) • Chamber Size : 450Mm X 300 Mm X 300 Mm • Furnace Uniformity + / - 2°C • Temp Recorder With 2 Channel Placed At Opposite Sides • Salt For Use With Two Times Top Up • Spare Heating Element 2Pc ) 25 In-Situ Metallography Kit ( • Items: Portable Grinder / Polisher, Grinding Discs, Lapping Cloths, Diamond Pastes, Aerosol Spray, Replication Film, Paste, Reflector And Gumming Tape For Excellent Contrast Or Transparent Replica - Film Thickness - 125 Microns, 30 Microns, Replica Liquid, Glass Slides ) 26 Automatic Electrolytic Polishing Machine ( • Function: Fully Automatic Electrolytic Polishing And Etching With Automatic Scanning Function • Preparation Time: Within 30 Sec • Electrolyte For Low / High Alloyed Steels & Aluminium • Pump And Magnetic Stirrer • Integrated Cooling System ) 27 Micro-Hardness Tester ( • Test Load : 10, 25, 50, 100, 200, 300, 500, 1000 Gm • Scale: Knoop & Vickers • Dwell Time: 5-90 Seconds Settable • Objectives : 10X, 20X, 40X, 60X • Loading And Unloading : Motorized • Measurement – Automatic And Or With Manual Micrometer Eyepiece. • Traverse: Automatic And Or Manual With Micrometer. • Focusing - Motorized Focusing With Manual Over-Ride • Computerized Imaging Attachment, Dedicated Software To Measure Hardness On Computer With Report Generation Facility • Accessories: Sheet Holder, Wire Holder, Hardness Test Block, Bulb, Indenter. ) 28 Cracked Aluminum Test Block ( For Penetrant Sensitivity Checking In Dpt ) ( Aluminum Test Piece That Measures 3 X 2 X 3 / 8 With A 1 / 8 Wide With A Milled Notch That Separates The Blocks Two Sides To Facilitate Side-By-Side Penetrant Comparison. The Test Block Is Used To Check The Strength Of “In-Use” Penetrants. This Is Done By Processing One Half Of The Block With “Used” Penetrant, And The Other Half With Fresh Penetrant. Can Be Used To Compare Sensitivity Of Different Penetrants Or Sensitivity Of New And Old Penetrants. Complies With Astm E165 And Asme Boiler And Pressure Vessel Code Section V & Iii, And Mil-I-23135-C. ) 29 Pie Gauge / Magnetic Flux Indicator ( To Be Made From Eight Ferrous Segments, Braised Into A Single Piece, Providing A Star Pattern Of Nonferrous Discontinuities. Eight Linear Discontinuities To Provide Indications In All Directions Non-Ferrous Handle With Pivot. Specification Compliance • Mil-Std-271 • Astm E709 ) 30 20Mhz Analog Cro ( Dual Trace ) , Bandwidth:- Dc ~ 20Mhz ( -3Db ) Y Deflection:- 5Mv / Div ~ 10V / Div. Rise Time:- <18Ns,Mag _70Ns :17.5Ns. Max Input:- 400V ( Dc+Acp-P ) 31 50Mhz Digital Storage Oscilloscope, Bandwidth 50Mhzreal-Time Sampling Rate 500 Msa / S, Equivalent Sampling Rate 50Gsa / S.Memory Depth: 32Kptstrigger Types: Edge, Pulse Width, Video, Slope, Alternativeunique Digital Filter Function And Waveform Recorder Function, Max Input:- 400V ( Dc+Acp-P ) 32 3D Model Showing Different Parts Of A Coal Fired Thermal Power Station 33 3D Model Showing Different Parts Of A Gas Fired Thermal Power Station 34 3D Model Showing Different Parts Of A Diesel Power Station 35 3D Model Showing Different Parts Of A Nuclear Power Station 36 3D Model Showing Different Parts Of A Hydro-Electric Power Station 37 3D Model Of Boiler Showing Its Different Parts Used In Coal Fired Thermal Power Station 38 3D Model Of Boiler Showing Its Different Parts Used In Nuclear Power Station 39 3D Model Of Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant 40.1 Colour Flex Chart Describing Different Parts Of A Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.2 Colour Flex Chart Describing Different Parts Of A Gas Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.3 Colour Flex Chart Describing Different Parts Of A Diesel Power Station Size:30× 40, Material: Pvc, With Roller 40.4 Colour Flex Chart Describing Different Parts Of A Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.5 Colour Flex Chart Describing Different Parts Of A Hydro-Electric Power Station Size:30× 40, Material: Pvc, With Roller 40.6 Colour Flex Chart Describing Different Parts Of Boiler, Used In Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.7 Colour Flex Chart Describing Different Parts Of Boiler, Used In Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.8 Colour Flex Chart Describing Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant Size:30× 40, Material: Pvc, With Roller 41 3-Phase Induction Motor Speed Control Using Pwm Inverter For Interpreting Speed-Torque Characteristics Using Vvvf Drive 42 Ups Trainer Kit ( 1Kva ) Output Voltage : 230 V Ac Nominal, Input Voltage : +12V Dc Battery. Capacity : 1Kva, Output Frequency : 50 Hz Accuracy : + 5%. Switching : Automatic. 43 Smps Trainer Kit Incl. ±5V, ±12V Input Voltage: Ac 100 – 264V 50 / 60Hz Output Voltage: 12V Dc, 0-5A Output Voltage: Adjustment Range: ±20% Protections: Overload / Over Voltage / Short Circuit Auto-Recovery After Protection Universal Ac Input / Full Range 100% Full Load Burn-In Test Cooling By Free Air Convection High Quality And High Performance Led Power Supply With A Metal Body For Hidden Installation For Led Lighting Design With Built-In Emi Filter, Improve Signal Precision. Certifications: Ce & Rohs No Minimum Load. Compact Size Light Weight. High Efficiency, Reliabiltiy & Low Energy Consumption Controller: Satandard 44 Commutation Kit Of Scr ( Class A To F ) Completely Self – Contained Stand – Alone Unit. Demonstrates The Principle And Various Methods Of Forced Commutation Of Scr. 1. Self-Commutation By Resonating Load ( Class “A” Method ) . 2. Self-Commutation By An L C Circuit ( Class “B” Method ) . 3. Complimentary Commutation ( Class “C” Method ) . 4. Auxiliary Commutation ( Class “D” Method ) . 5. External Pulse Commutation ( Class “E” Method ) . * Supply Required 230V, 50Hz Ac. * Built-In Ic Based Dc Regulated Supply And Led Indication For Supply “On”. * Built-In Load Facility In The Form Of Led’S. * Connecting Each Circuit Separately And Verifying Its Principle. * Multicoloured Test Points Are Provided To Observe The Waveform And Voltages. * Set Of Required Number Of Patch Cords. * Housed In An Elegant Cabinet With A Well Spread Intelligently Designed Circuit Layout Engraved On The Front Panel. * Strongly Supported By A Comprehensive Instruction Manual Complete With Theory And Operating Details. 45 Colour Flex Chart Describing Single Line Diagram Of A Given Distribution System ( Lt & Ht ) Size:30× 40, Material: Pvc, With Roller 46 Colour Flex Chart Describing Short Transmission Line ( 220Kv ) Size:30× 40, Material: Pvc, With Roller 47 Colour Flex Chart Describing Medium Transmission Line ( 220Kv ) ( Both T & Π-Model ) Size:30× 40, Material: Pvc, With Roller 48 Power Factor Improvement Kit Using Static Condenser Including Load R-L Load Of At Least 2Kva With Appropriate Capacitor Bank. 49 Setup For Load Test On 1-Ph Induction Motor: Load Test Kit Of 1-Ph Induction Motor ( 1Hp, 230V, 50Hz ) 50 Loading Test Kit Of 3-Phase Alternator: ( 2Kw, 415V, 50Hz ) With 3-Ph R-L Load Box Coupled To A Dc Motor; Capable To Perform As Synchronous Motor Test With Dc Generator Load; Integrated With All Required Measuring Instruments 51 Speed Control Kit Of Stepper Motor Including Reversing Arrangement With 8051 Microcontroller: Stepper Motor Of Appropriate Capacity To Be Served By 8051Μc 52 Speed Control Kit Of Ac Servo Motor: Motor Spec: 3000Rpm, 200W, 0-240V, Control Torque: Standard With All Needed Accessories 53 Speed Control Kit Of Dc Servo Motor: •Voltmeter Vdc 3.5 Digit. 200Mv •Rpm Indicator For Speed Measurement •Voltmeter Vdc 3.5 Digit 20V Power Supply: •Ic Regulation In Controller Circuit Power Supplies •Operated On Mains Power 230V, 50Hz +10% Features: •Position Control Of A 12 Volt, 1 Amp Dc Geared Pm Motor ( 50 / 60 Rpm ) •Calibrated Dials With 1 Degree Resolution For Reference And Output Position •Two 360 Degree Servo-Potentiometers •Built In Step Signal •Built In Waveform Capture / Display Card For Study Dynamic •Electronic Techogenerator For Feedback •Non-Contact Eddy Current Break For Load •Speed Control Of 12V, 4W, Permanent Magnet Dc Motor •Speed Range Up To 3000 Rpm ( Typical 54 Mcb Test Kit For Performing Load Test: Kit Should Be Able To Perform Short-Circuit, Over Load, Thermal Trip Test For Mcb With Rating Upto 30A 55 Dismantled Elcb & Rccb Kit For Demonstration Purpose: Elcb: Single Phase 2 Pole Elcb, Rccb, Isi Marked 32A Mcb With High Voltage, Overload Protection, Current 3 To 30 Ma Rccb: Breaking Capacity 10 Ka, Frequency, 50 Hz, Number Of Poles 2P, Operating Characteristics: Ac Rated Current 40 A, Sensitivity 30 Ma, Standard, Is 12640-1 & Iec 61008-4, Test Button Yes 56 Testing Kit For Percentage Differential Protection Of Transformer Using Transformer Differential Relay ( Electromagnetic / Μp Based / Static ) : Standard For Laboratory Purpose 57 Colour Flex Chart Describing Different Parts Of Acb & Vcb ( 33Kv, 15Mva ) : Size:30× 40, Material: Pvc, With Roller 58 Experiment Kit To Measure Solar Radiation Using Pyranometer On Tilted Surface At Different Angle Inclination: Standard For Laboratory Purpose 59 Colour Flex Chart Describing Different Parts Of Solar Flat Plate Collector & Solar Concentrating Collector & Trough Collector: Size:30× 40, Material: Pvc, With Roller 60 Experiment Kit To Measure Thermal Performance Of Solar Water Heating System: Standard For Laboratory Purpose 61 3D Model Describing Different Parts Of ( I ) Solar Street Lighting System & ( Ii ) 1Kw Small Wind Turbine ( Swt ) : 3D Model For Laboratory Purpose 62 Setup Of 250Wp Solar Pv Plant Including All Accessories: Solar Panel Specifications:Peak Power: 250W; Maximum Power Voltage: 20.2V; Maximum Power Current: 12.38A; Open Circuit Voltage: 23.9V; Short Circuit Current: 13.12A; Power Allowance Range: + / - 3% Hybrid Inverter Specifications: Nominal Battery Voltage: 12V; Continuous Power Output: 1000W / 1000Va; Surge Power: 2000Va Output Voltage: 230V Ac; Output Frequency: 50Hz / 60 Hz; Output Waveform: Pure Sine Wave; Maximum Solar Input Power: 600W; Maximum Open Circuit Solar Input Voltage: 55V; Maximum Solar Charging Current: 50A; Maximum Mains Ac Charging Current: 20A; Maximum Combined Charging Current: 50A; Peak Efficiency: 93% Battery Specifications ( Per Battery ) : Nominal Voltage: 12V; Nominal Capacity: 50Ah ( 10H Rate ) / 55Ah ( 20H Rate ) ; Maximum Charging Current: 25A; Self-Discharging Rate: <3% Per Month; Cycle Lifetime At 30% D.O.D.: 1000-1100 Pressure Control: Safety Valve Installed Terminal Type: F13 ( Bolts And Washers Included ) Operating Temperature: From +10C To +40C 63 Setup Of Small Wind Turbine Plant Including All Accessories: Standard For Laboratory Purpose 64 Study Kit Of Assembling And Dismantling Of Csp Plant Using Parabolic Trough Or Disc: Standard For Laboratory Purpose 65 Study Kit For Assembling Vertical Axis Or Horizontal Axis Swt: Standard For Laboratory Purpose 66 Digital Lcr Multimeter: Digital Lcr Meter ( Battery Operated ) , Model: 4070 Range: 0.1Μh To 20H, 0.1Pf To 2000Μf, 0.1Ohm To 20Mohm Accuracy: 2Mh, Resolution: 1Uh, Accuracy: 20Mh, Resolution: 10Uh, Accuracy: 200Mh, Resolution: 100Uh Accuracy: 2Nf, Resolution: 1Pf, Accuracy: 20Nf, Resolution: 10Pf, Accuracy: 200Nf, Resolution: 100Pf, Accuracy: 2Uf, Resolution: 1Nf, Accuracy: 200, Resolution: ± ( 0.8 Percent+5 ) 0.1, Accuracy: 2K, Resolution: 1, Accuracy: 20K, Resolution: 10, Accuracy: 200K ( Make: Metravi ) 67 Handheld Power Meter Or Power Analyzer With Socket: Voltage: 85V-265V, Current; 0.002A~20A, 50Hz, 1-Ph 68 Analog Power Factor Meter ( 1-Ph & 3-Ph ) : Standard For Laboratory Purpose 69 Multimeter With Clamp Meter Arrangement With Hfe Lcr: Standard For Laboratory Purpose ( Make: Metravi ) 70 Three Phase Power Measurement Kit ( Y & Δ Load R-L Load ) Incl. 3-Ph Wattmeter With 2Kw Range: Standard For Laboratory Purpose 71 Kit For Troubleshooting Single Phase Electronic Energy Meter: 230V, 1-Ph, 50Hz 72 Three Phase Trivector Meter: Salient Features Class 0.5S As Per Relevant Is And Iec Standards 5A Current Rating 3 Phase 4 Wire 4 Quadrant Measurement Anti-Tamper Features Self-Diagnostic Capability Multiple Tariff / Time Of Day Feature Bidirectional Energy Recording Up To 4 Maximum Demand Registers Load Survey ( Interval Data ) Features Up To 12 Reset Backups Optical Port / Rs 232 / Rs 485 / Ir / Irda / Rf ( 2.4 Ghz / 865-867 Mhz ) ( Optional ) ( Make: L&T ) 73 Brake Test Kit Of Dc Series Motor: 220V Dc, 2Hp With Allied Required Accessories 74 Back-To-Back Test Kit Of Single Phase Transformer: 1-Ph, 240V, 50Hz, 1Kva ( 2 Nos. ) Identical Transformers With Other Standard Accessories 75 Isolation Transformer Kit: 230V; 230V / 10Amp 230V; 230V / 5Amp 76 Pulse Transformer Kit: Dc Supply: Two 5V & 12V, Pulse Generator: Two Selectable Frequency & Variable Pulse Width, Mains: 230V / 50Hz, Adequate For Cro Observations, Optocoupler: One, One Ferrite Wired 1:1 77 Colour Flex Chart Describing Different Vector Groups Of Theree Phase Transformer: Size:30× 40, Material: Pvc, With Roller 78 Full-Wave Fully Controlled Bridge Rectifier Kit With & Witout Filter Arrangement: Standard For Laboratory Purpose 79 Kit To Find The Characteristics Of Zener Diode: Standard For Laboratory Purpose 80 Kit To Find The Characteristics Of Mosfet: Standard For Laboratory Purpose 81 Ujt Relaxation Oscillator Trainer Kit: Standard For Laboratory Purpose 82 Singlestatge Transistor Trainer Kit ( Ce-Mode ) : Standard For Laboratory Purpose 83 Trainer Kit For Sr, D, Jk & T – Flip-Flop: Standard For Laboratory Purpose 84 Trainer Kit For Realization Of Encoder And Decoder Circuit: Standard For Laboratory Purpose 85 Trainer Kit For Realization Of Multiplexer And Demultiplexer Circuit: Standard For Laboratory Purpose 86 Trainer Kit For Implementing Dac & Adc: Standard For Laboratory Purpose 87 Connector Cables For Ade Lab. Of Different Types: Standard For Laboratory Purpose 88 Arduino Uno R3 Board With Lcd1602, Servo Motor, Relayes, Processing And C Code, Beginner Starter Kit With Mannual And Allied Accessories: Standard For Laboratory Purpose 89 Trainer Kit For 8051 Μc Programming: Trainer Kit For 8051 Μc Programming With Keypad To Write Program 90 Trainer Kit Using 8051 Μc For Measurement Of Ac Voltage, Current, Frequency & Phase Angle Using Suitable Ct, Pt, Zcd, Adc, Etc. 91 Demonstration Kit For Identifying Pvc, Xlpe, Vir, Catenary, Frls, Frlsh Cables / Wires Of Different Current Rattings: Standard For Laboratory Purpose 92 Megger: Insulation Tester ( 500V ) With Hand-Driven Gen.: 500V, 2500 Mega Ohms 93 Megger: Insulation Tester ( 2500V ) With Hand-Driven Gen. 2.5Kv, 2500 Mega Ohms 94 3-Ph Smart Energy Meter For Lt Power Measurement, 3-Ph, 415V, 4-Wire, Kwh Meter, Current: 10-60A, Class 1.0 Accuracy As Per Relevant Is And Iec Standards, With Lcd Display [ Make: L&T ] 95 Trainer Kit For Dc Chopper Drive With Resistive Load & Dc Separately Excited Motor. 1 / 8 Hp, 200Vdc Operation, Current Limit Protection, Speed Control Using Frequency And Duty Cycle Variation, Jones Chopper Based Control, Motor Loading Arrangement Can Be Provided / Resistive Load May Be Connected, Other Variety Of Controllers With Converter Control With Closed Loop Controller 96 Trainer Kit For Controlling The Speed Of Separately Excited Dc Motor By Changing The Firing Angle Of Scr Using 1-Ph Full Converter. Power Supplies: • Power Supply +15Vat 150Ma • Isolated Supply 0-220V At 5A. • Operated On Mains Power 230V, 50Hz +10% Digital Meters: • Voltmeter 2000V Ac • Voltmeter 2000V Dc • Ammeter 2A Dc Components Are Mounted On The Panels Are: • Scr Tyn604 ( 2 Nos. ) • Diode 1N5408 ( 2Nos. ) • Diode Ba159 • Ac Phase Control By Gate Control Firing Circuit. • Snubber Circuit. Load: • 1 / 2Hp Dc Shunt Motor. • Inductor As Load 230V, 1A • Lamp Load 230V, 60W 97 Μcontroller Based 3-Ph Syn. Motor Drive: Trainer Kit For Controlling The Speed Of Synchronous Motor ( 1Kva ) Drive Using Μc. 98 Demonstartion Kit Showing Different Types Of Power Semiconductor Devices With Heat Shink E.G. Scr, Igbt, Gto, Mosfet, Standard For Laboratory Purpose. 99 Kit For Magnetic Control Of Im: Control And Power Circuit For ( I ) Forward And Reverse Rotation Of Squirrel Cage Im Using Contactor, ( Ii ) Automatic Star-Delta Starter Of Squirrel Cage Im, ( Iii ) Dynamic Braking Of Squirrel Cage Im, Standard For Laboratory Purpose. 100 Screw Driver Set, Standard For Laboratory Purpose. 101 6” Slide Range, Standard For Laboratory Purpose. 102 Wire Stripper, Standard For Laboratory Purpose. 103 Crimping Tool ( 1 Sq. Mm. To 6 Sq. Mm. ) . 104 2.5 Sq. Mm. Stranded Pvc Copper Wire 105 1.5 Sq. Mm. Stranded Pvc Copper Wire 106 1 Sq. Mm. Stranded Pvc Copper Wire 107 Soldering Kit: 20W With Solder Material 108 Contact Type Tachometer ( Range: 0-10, 000 Rpm ) 109 Set-Up With Different Type Tl Lamps ( Conventional & Led ) With Fittings Containing Electrimagnetic Ballast / Electronic Ballast Etc.: Tl Fittings With: 1. Electronic & Electromagnetic Ballast For ( I ) Single 40W, 240V, 50Hz Tl, ( Ii ) 2X40w, 240V, 50Hz Tl, 2. 20W Led Tl With Fittings Incl. 110 3-Ph Capacitor Bank Of 2-4Kva For Correcting Power Factor Of 415V, 50Hz, 1500 Rpm, 2Hp, 3-Ph Squirrel Cage Im With Facility To Connect The Stator Of The 3-Ph Im Both In Star & Delta Mode And A Tri-Vector Meter Having Facility To Measure Kw, Kva, Kwh, Kvarh, Pf. 111 Transformer Oil Breakdown Strength Kit: Breakdown Strength Kit With 5 Ltr. Fresh Transformer Oil, Standard For Laboratory Purpose. 112 Chart For Demonstration Of Different Fire Extinguishers: Colour Flex Chart Describing Different Types Of Fire Extinguishers ( 4 X 3 ) , Material: Pvc, With Roller 113 Chart For Demonstration Of Artificial Respiration ( Cpr ) And Prepare A Report.: Colour Flex Chart Describing Different Types Of Artificial Respiration ( Cpr ) ( 4 X 3 ) , Material: Pvc, With Roller.
Contract Date: Dec 10, 2024 Contract Value : 11.21 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
21.
Educational and Research Institute #10618039 Price Bid
Supply Of Equipment And Other Accessories To Provide Leased Line Internet Facility With 100Mbps - 2 Supply Installation And Commissioning Of Firewall For Leased Line Internet Facility With 100Mbps ( 1:1 ) Nfirewall N• Media Converter Single Mode N• Applicance Should Be Rack Mountable N• The Platform Must Be Supplied With Atleast 6Nos. Of Auto Configurable Ports N• The Platform Should Support Vlan Tagging ( Ieee 802.1Q ) N• Support A Minimum Of 1000 Vlan’S N• The Firewall Interfaces Have To Support The Un-Numbered Ip Address N• The Firewall Should Support Isp Link Load Sharing N• Should Support Total 450 Users Memory 2Gp, Compact Flash 4Gb, Hdd250gb Or Higher Firewall Throughput N• ( Udp ) -10, 000Mbps Firewall Throughput N• ( Tcp ) -8, 000Mbps Sec N• Should Support 200 Or More With Globally Support Protocols. N• Vpn Throughput-1, 150Mbps Utm Throughput-1, 400Mbps N• Including Firewall Configuration Charges ( User Rights, Ip Address Controls, Website Restriction, Create And Manage Ip Groups, Internet Up & Down Speed Control, Internet Usage For Ip Groups, Etc ) N• Should Support Ips / Ids N1. A ) Subscription: 3 Years Subscription And Maintenance N• Gateway Anti-Virus & Anti-Spyware, Web And Application Filter. N• All Internet Based Application Should Be Supported For Filtering Like Telnet, Ftp, Smtp, Http, Dns, Icmp, Dhcp, Arp, Rpc, Snmp, Mime, S / Mime, Lotus Notes, Ms-Exchange Etc N• Web Application Firewall, Virtual Private Network, Wireless Wan, Bandwidth Management, On-Appliance Reports Based On User Group Activity Threat Based, Total Value Subscription Includes Anti Malware, Anti Spam, 8X5 Support, Hardware Warranty And Rma Fulfillment N 3 Network Managed Switch Specifications N48 Port Gigabit L2 Managed Switch N1. 48 Rj-45 Connectors For 10Base-Tx / 1000Base-T, Including 2 Ncombo Ports With Mini Gbic / Sfp Slots N2. Auto Medium Dependent Interface ( Mdi ) And Mdi Crossover ( Mdi-X ) N3. Auto Negotiate / Manual Setting N4. Unshielded Twisted Pair ( Utp ) Category 5E Or Better For 1000Base-T N5. System, Gigabit Link / Act, And Speed N6. 128 Active Vlans ( 4096 Range ) N7. Port-Based And 802.1Q Tag-Based Vlans N8. Management Vlan N9. Poet Mirroring Dhcp / Bootp Client System Log Configuration Upload And Back Mirroring Http Or Tftp N10. Wifi Router N11. With 3 Years Warranty 4 Networking For 100 Computers From Point Of Firewall For Leased Line Internet Facility With 100Mbps ( 1:1 ) Nnetworking For 100 Computers From Point Of Firewall ( At Two Rooms ) With Cat6 Cable 4 Pair Along With 2-Routers ( Inclusive Of All ) Nwith 9U Rack ( Wall Mounting ) Depth 450 Mm With 3 Power Sockets And Cable Manager N
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
23.
Communications and Information Technology  #10440466 Price Bid
The Supply , Laying , Installation , And Comprehensive Warranty Maintenance Services Of Networking It Equipments In Pwd Office , Lucknow- Networking 200 Point 1 L2 Gigabit Managed Switch 24 Port Switch Should Have Minimum 24 10 / 100 / 1000 Mbps Ports And 4Sfp+ For 10G Fibre Connectivity. Switch Shall Have Non-Blocking Architecture With Minimum 128 Gbps Switching Capacity And Minimum 95 Mpps Packet Forwarding Rate Or Higher The Switch Shall Support Min. 16K Mac Address. The Switch Shall Support 6 Kv Surge Protection On All Ethernet Ports Layer 2 Features The Switch Should Support Spanning Tree Protocols As Per Ieee Standards Ieee 802.1D, Ieee 802.1W And Ieee 802.1S The Lan Switch Should Have Ieee 802.1Q Vlan Encapsulation, Up To 4000 Vlan Ids. Switch Shall Support Multicast Vlan, Port Based Q-In-Q Quality Of Service It Should Support 802.1P Priority Queues ( 8 Queues ) Network Security The Lan Switch Should Have The Capability To Support Access List Based On Ipv4 / V6 Address, Protocol Type, Ipv6 Flow Label, Vlan-Id, Mac-Id, Dscp, Ipv6 Traffic Class, Tcp / Udp Port, Switch Port.It Should Support ; Local Database ;Radius Authentication ; Tacacs+, It Should Have Ip-Mac-Port Binding. Product Certifications It Should Have Ce, Fcc, Cul, Vcci, Cb, Certifications 2 Pigtel : Sc-Sm Simplex 1M 3 Fiber Module 1-Port Mini-Gbic Lx Single- Mode Fiber Transceiver ( Up To 10Km, Support 3.3V Power 4 Fiber 6 Core : O. F.Cable 06F Outdoor - Armoured Unitube Sm-Hdpe Sheath ( Rate Per Meter ) 5 Liu 12 Port With Accessories - Rack Mount - Loaded ( Sc ) Sm Loaded ( Sc ) Sm 6 Patch Cord Fibre - Lc-Sc Sm Duplex Length- 1M 7 Utp Cat 6 Cable Box : Cat6 Utp 23Awg Solid:305 Meter 8 Patch Panel Cat 6 Utp Keystone Type- 24 Port-Fully Loaded 9 Cat6  Patch Cord 3 Mtr : Cat6 Utp 24Awg Patch Cord:3M, Plug 30U Snagless 10 Cat6  Patch Cord 1 Mtr : Cat6 Utp 24Awg Patch Cord:3M, Plug 30U Snagless 11 Cat6 I / O Aface Plate : Face Plate-Single Jack Squuare 12 Jack Cat 6 Keystone Utp : White 13 Back Box : For Single, Dual Cat 6 Square 14 15 U Rack With Accessories 15 9U Rack With Accessories 16 Fixing Of Pvc Pipe Casing Capping ( Quantity Per Mtr. ) 17 5 Kva On Line Ups Igbt-Pwm With Inbuilt Isolation Transformer Minimum 16 Nos. 150 Ah 12V Smf Vrla Battery Battery Rack / Trolly Input Power : Single Phase 160V - 260V Sinewave, 50Hz Output Power : Single Phase 230V + / -1% Sinewave 50 Hz 3 Year On Ups 2 Year On Battery Inverter Efficiency : >=80% Overload Capability >= 110% For ≥10 Minutes Degree Of Protection : Ip21 Indicators For Mains Presence, Battery Charging And Discharging, Output Over Load, Low Battery Voltage Protection Of Over Voltage, Short Circuit & Over Load At Ups Output Terminal Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery 18 Power Work For Network Power Rack And Giving Power Points By Ups 19 Crimping, Punching, Fiber Work Connectivity Testing And Lan Establishment Charges. ( Per Point ) 20 Wall Mounting Of Rack, Patch Panel, 24 Port Switch, Installation / Fixing Charges. 21 Laying Of Utp ( Rate Per Mtr. ) 22 Laying Of Fiber Cable With Hard Plastic Pipe ( Rate Per Mtr. ) 23 I / O Box Fixing & Termination 24 Fire Wall For 500 Users Type: Ngfw  Form Factor ( Ru ) : 1  Features: Layer 3 - Layer 4, Nat, Vpn, Application Visibility And Control ( Avc ) , User Identity, Next Generation Intrusion Prevention System ( Ips ) , Zero Day Protection / Advance Malware Protection, Web Security Essentials / Url Filtering  Traffic Handled: Tcp, Udp, Http / Tcp, Tcp / Udp  Throughput With All Features Enabled ( Under Test Condition ) ( Mbps ) : 7000  Throughput ( Real World / Prod Performance ) ( Under Test Condition ) ( Mbps ) : 7000  Concurrent Session / Concurrent Connection: 20M  New Session / Connection Per Second: 250K  Type Of Interface Supported Multiselect: Ge Copper  Number Of Ge Copper Interface: 6  Number Ofcol / Wan Ports: 4  Number Of Ipsec Vpn Peers Supported ( Site To Site ) : 10000  Number Of Ipsec Vpn Peers Supported ( Client To Site ) : 12500  Number Of Ssl Vpn Peers Supported ( Client To Site ) : 7500  High Availability Support: Yes  Interface Expansion Slots Supprted: 1  Firewall Policies - License: Yes  Details Of The Firewall Policies For The Firewall Provided With The License: Web Security Essentials / Url Filtering, Ips License, Application Visibility License, Apt ( Advance Persistant Threat ) License ( Anti Malware Protection , C& C Attacks, Geo Ip Protection, Zero Day Threat Protection ) , Gateway Anti Virus, Gateway Anti Spam  Ngips Sigature Supported: 25000  Security Intelligence: Ip, Url, Domain  Certification: Common Criteria / Ndpp / Nss / Icsalabs  Ipv6 Ready From Day 1: Yes  On Site Oem Warranty ( Year ) : 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
24.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
26.
Rural Development #10253352 Price Bid
Provide Provide And Install Cc Tv Camera At Savroli Grampanchayat Tal Khalapur Dist Raigad , Supply And Install Cc Tv Camera , Ip Bullet Camera • 1 / 2.7” 4Mppscmosimagesensor • 20Fps@1080P ( 1920×1080 ) • H.265+ / H.265Dual-Streamencoding • 3.6Mmlens ( 2.8Mmoptional ) • Irrangeof20mtrs, Ip67, Poe • Colourfull Night Recording , • Full Hd 2 Mp Bullet Camera, • H.265+ / H.265Dual-Streamencoding Dwdr, Day / Night ( Icr ) , 3D-Dnr • 3.6Mm Lens, Ir 20Mtr, • Ir Light, Day / Night, • Motion Sensor, • Weatherproof Ip66 , Ip Bullet Camera • 1 / 2.7”4Mp Cmos Image Sensor • 20Fps@ 1080P ( 2592×1520 ) • H.265+ / H.265Dual-Streamencoding • Dwdr, Day / Night ( Icr ) , 3D-Dnr, Roi, Awb, Agc, Blc, Hlc •3.? Mm Ir Range Of30mtrs, Ip67, Poe , Full Hd 2 Mp Bullet Camera, • 20Fps@ 1080P • H.265+ / H.265Dual-Streamencoding Dwdr, Day / Night ( Icr ) , 3D-Dnr • Ir 30Mtr, Ir Light, Day / Night, • 2.8-12 Mm Lenc Weatherproof Ip66 , Ip Bullet Camera • 1 / 2.7”2Mppscmosimagesensor • 20Fps@1080P ( 1920×1080 ) • H.265+ / H.265Dual-Streamencoding • 3.6Mmlens ( 2.8Mmoptional ) • Irrangeof 20Mtrs, Ip67, Poe Colourfull Night Recording , Full Hd 5 Mp Bullet Camera, • 20Fps@ 1080P ( 2592×1520 ) • H.265+ / H.265Dual-Streamencoding Dwdr, Day / Night ( Icr ) , 3D-Dnr • Ir 30Mtr, Ir Light, Day / Night, • 2.8-12 Mm Lenc • Digital Zoom • Optical Zoom •Weatherproof Ip66 , • Full Hd 5 Mp Bullet Camera, • H.265+ / H.265Dual-Streamencoding Dwdr, Day / Night ( Icr ) , 3D-Dnr • 3.6Mm Lens, Ir 20Mtr, • Ir Light, Day / Night, • Motion Sensor, Weatherproof Ip66 , Ip Bullet Camera 1 / 2.7” 4Mp Ps Cmos Image Sensor • 20Fps@1080P ( 2592×1520 ) • H.265+ / H.265 Dual-Stream Encoding • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom • Ir Range Of 50 Mtrs, Ip67, Poe , Ip Bullet Camera 1 / 2.7” 2 Mp Ps Cmos Image Sensor • 20Fps@1080P ( 2592×1520 ) • H.265+ / H.265 Dual-Stream Encoding • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom • Ir Range Of 50 Mtrs, Ip67, Poe , Ip Bullet Camera • 1 / 2.7”2Mp Cmos Image Sensor • 20Fps@ 1080P ( 2592×1520 ) • H.265+ / H.265Dual-Streamencoding • Dwdr, Day / Night ( Icr ) , 3D-Dnr, Roi, Awb, Agc, Blc, Hlc • 2.8-12 Mm Lens • Digital Zoom • Optical Zoom Ir Range Of30mtrs, Ip67, Poe , Dvr • 4Ch 5Mp Full Hd • Insta On Cloud • Up To 8Mp Resolutionpreview And Playback • 1Ch Audio In • Hdmi, Vga, 1 Sata Port • Support Multi-Brand Hd Cameras , • Nvr • Support Up To 1Ch@8Mp / 32Ch@1080Pdecoding • H.265 / H.264Dualcodecdecoding • Up To 8Mp Resolutionpreview And Playback • Max 100 Mbps Incomingbandwidth • Support 1 Sata Hdds Up To 6Tb, 2Usbports ( 2.0 ) • Hdmi / Vga Simultaneous Video Output • Support Multi-Brand Network Cameras • Onvifversion2.4Conformance , Dvr • 4Ch 2Mp Full Hd • Insta On Cloud • Up To 8Mp Resolutionpreview And Playback • 1Ch Audio In • Hdmi, Vga, 1 Sata Port • Support Multi-Brand Hd Cameras , Dvr • 16Ch 5Mp Full Hd • Insta On Cloud • 1Ch Audio In • 2 Sata Port • Up To 8Mp Resolutionpreview And Playback • Support Multi-Brand Hd Cameras Hdmi, Vga , Dvr • 16Ch 2 Mp Full Hd • Insta On Cloud • 1Ch Audio In • 2 Sata Port • Up To 8Mp Resolutionpreview And Playback • Support Multi-Brand Hd Cameras Hdmi, Vga , • Nvr • Support Up To 1Ch@8Mp / 4Ch@1080Pdecoding • H.265 / H.264Dualcodecdecoding • Up To 8Mp Resolutionpreview And Playback • Max40mbpsincomingbandwidth • Support 1 Sata Hdds Up To 6Tb, 2Usbports ( 2.0 ) • Onvifversion2.4Conformance , • Nvr • Support Up To 1Ch@8Mp / 8Ch@1080Pdecoding • H.265 / H.264Dualcodecdecoding • Up To 8Mp Resolutionpreview And Playback • Max40mbpsincomingbandwidth • Support 1 Sata Hdds Up To 6Tb, 2Usbports ( 2.0 ) • Onvif Version2.4 Conformance , • Poe Switch • Poeport:4, 10 / 100Mbpsrj45ports , Uplinkport:2, 100Methernet Port • Providesupto30wattsperpoeport • Plug-And-Play Installation • Ieee 802.3At And Ieee 802.3Af Powerover Ethernet ( Poe ) Compliant • Networkprotocol:Ieee802.3, 802.3U, 802.3X, 802.3Af • 250 Mtr Range , • Poe Switch 2Gigabit Ethernet Port • Poeport:8, 10 / 100 Mbpsrj45ports , Uplinkport:2, Gigabit Ethernet Port • Provides Up To 30 Watts Per Poe Port • Plug-And-Play Installation • Ieee 802.3At And Ieee 802.3Af Powerover Ethernet ( Poe ) Compliant • Networkprotocol:Ieee802.3, 802.3U, 802.3X, 802.3Af • 250 Mtr Range , • 5Amp Smps • Capable To Sending Power Upto 150 Mtr Range , • 10 Amp Smps • Capable To Sending Power Upto 150 Mtr Range , • Gigabitswitch • Auto-Negotiates Port Speed To 10Mbps, 100Mbps, Or1000mbps • Plug& Playinstallation • Uses 802.3Az Energy Efficientethernet To Reduce Power Usageautomatically Without Sacrificingperformance , 4Tb [ 4000 Gb ] Special Cctv Surveillancehdd Features-All Frame 4K, Supports Up To 64Cameras Enhanced Workload Rating Designed For24*7Systems [ Not Computerhdd ] , 2Tb [ 2000 Gb ] Special Cctv Surveillancehdd Features-All Frame 4K, Supports Up To 64Cameras Enhanced Workload Rating Designed For24*7Systems [ Not Computerhdd ] , 2-6-Core Optical Fiber + Labor Charges , Media Converter , Cctv Cable 1+3, 2 Power, 1 Video Cable , Nvrconfiguration , Fitting I / O, Mounting Cameras— Nos Nvrconfiguration, Cctvvideocrimping-Nos Mobile, Pc, Routerconfiguration, 4”*4”I / O Box With F Aceplate Ties— , Wireless Access Point Device , Pure Copper Cat-6 Cable Includinglabour Charges +Ties+Huks , Wireless Access Point Configuration , 4Unetwork Rack , 2 / 3 Urack , Iball / Zebronicups600va , Screen To Monitor Cctv 18.5” , Fiber Splicing Charges , Dvr Nvrrackinstallation , Housing To Protect Outdoor Ip Cameras , 12-15Ft Metal Pole With Erection , 2 Hdmi Hdtv Screen32” , Dvr Configuration , Wire Rope , Wireless Repeater , Router 600Mbps , Cisco 1800 Router , Two In One Gateway Router , 5Mtr Hdmi Cable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
27.
Educational and Research Institute #10223754 Price Bid
Supply,Installation And Commissioning Of Sip Server Based Epabx Solution Supply, Installation And Commissioning Of Sip Server Based Epabx Solution , Item Description , Sip Extension Licenses, Compatible For Existing Ippbx Server , Redundant Sip Extension Licenses, Compatible With The Existing Ippbx Server. , Sip Extension Licenses, Compatible With The Existing Ippbx Server. , Aup License For Existing Ip Pbx Server , A) 700 Sip Extension Licenses (Scalable) , Gateway: Sip/Mgcp, 8 Fxs, T.38 Fax, G.711.G.723.1.G.729A/B, Tr069/ Snmp, Ipv6, Ims , Gateway: Sip/Mgcp, 16 Fxs, T.38 Fax, G.711.G.723.1.G.729A/B, Tr069/ Snmp, Ipv6, Ims , Gateway: Sip/Mgcp, 24 Fxs, T.38 Fax, G.711.G.723.1.G.729A/B, Tr069/ Snmp, Ipv6, Ims , Gateway: Sip/Mgcp, 32 Fxs, T.38 Fax, G.711.G.723.1.G.729A/B, Tr069/Snmp,Ipv6, Ims , 1.5 Mtr Line Cord For Fxs Gateway To Patch Panel. Make: Best Net , Supply And Installation Of 6U Wall Mount, With Cable Manager, Fan Module, Shelf, Pdu Etc , 1.5 Mtr Line Cord For Fxs Gateway To Patch Panel. Make: Best Net , Supply And Installation Of 6U Wall Mount, With Cable Manager, Fan Module, Shelf, Pduetc , Supply, Installation And Termination Of 24 Port Straight, Cat6a, Loaded Patch Panel. , Service Charges For Removing Voice Node Cables From Existing Patch Panel And Racks, Re- Routing The Cables To New Rack, Re-Terminating To New Patch Panel, Dressing Of Cables, Testing And Identification. , Service Charges For The Dressing Of Cables, Testing And Identification From Rack To Work Station. , Monthly Charges For Onsite Support Engineer For Maintenance Of Complete Telephone Network, Post Installation. , Installation, Testing And Commissioning Charges For Gateways Configuration Of Server With Additional Licenses , Comprehensive Annual Maintenance Contract Charges After 1Yr Warranty. , 2Nd Year , 3Rd Year , 4Th Year , 5Th Year
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
29.
Housing Urban and Rular Development #10052012 Price Bid
supply installation testing and commissioning of Of Router, Network Items And Server In The Designated Server Area Of Diac At 2Nd Floor Of S Block, Delhi High Court, New Delhi-Supplying, Installation, Testing & Commissioning of Router alongwith software features and rack unit, 6 x 1G WANSD-WAN-enabled, 5G/LTE-ready modular enterprise branch router with 1 x PIM, 1 x NIM, and 1 x SM slot 10G IP throughput 2G SD-WAN throughput 4 x RJ45 + 2 x SFP embedded ports, up to 1G WAN Dual power supplies converged branch infrastructure along with superior throughput Network Plug-n-Play Connect for zero-touch device deployment at a speed up to 100 Mbps to 1 Gbps Mbps having Default memory double-data-rate 3 (DDR3) - 4 GB, Flash Memory - 8GB,Storage (M.2 SSD) default 16 GB,SD-WAN IPsec Throughput(1400Bytes) Up to 1.5Gbps, onboard WAN or LAN 10/100/1000 ports - 4 Nos, SFP-based ports- 1 No along with configuration, security licence key, mounting kit, blank plate and SNC with the existing network system i/c testing, connections & 5 year complete warranty etc. complete as required. 2 Supplying and Fixing of Wall Mount 12U Rack, with 600 depath, Front Glass Door with Lock, 2 pairs of Mounting Rails :- Standard Accessories:- 1U Cable Manager, Roof Mounted Fan Unit / 90 CFM / 230V AC,6 Way 5 Amp Power Distribution Unit, Mounting Hardware including Blank/Filler plate unit etc to cover the space etc. complete as required. 3 Supplying, installation, testing & commissioning of Layer-2 Twenty Four Port (24) UPOE Downlink & Uplinks Configuration 10/100/1000/10000 Ethernet Gigabit ports and Four(4) 10 G SFP uplinks, Dual Core CPU with 1024 MB per sec Memory (DRAM) and 2GB flash memory, Depending on the switch model, the IOS image automatically configure either the LAN Lite, LAN Base, or IP Lite feature set. LAN Lite models have reduced functionality and scalability for small deployments with basic requirements & stacking bandwidth 80 Gbps, IPv6 routing entries 1500, multicast routing scale 1000. Packet buffer per SKU 6mb buffers for 24- port gigabit ethernet models, .Up to 1TB of stacking bandwidth: With Stackwise-1T, Flexible and dense uplink offerings with 100G, 40G, 25G, Multigigabit, 10G, and 1G modular uplinks, Mixed Stacking with Backward Compatibility – Stack your X fiber switches withand X Multigigabit switches, bringing stackable high-speed fiber to the access, Highest Multigigabit Ports: With standalone and Stackwise-1T, X models enable 48 mGig ports in standalone and 448 mGig ports with an 8-member stack, Highest 90W UPOE+ Density: Enable your OT/IT needs with up to 36 ports of 90W UPOE+ for standalone or 288 ports of 90W UPOE+ with a 8-member stack, Stack Power with Backward Compatibility:.100G IPsec in hardware: With the new 2.0Sec UADP ASIC, the X comes with 100G line rate IPsec to enable various options for new edge connectivity Secure Tunnel connectivity: With the new edge, the C9300X enables secure connections to Secure Internet Gateway, Cloud Service Providers and Site to Site connectivity using IPsec tunnel with AES-256 Encryption and speeds up to 100G. 4 Supplying, Installation, Testing & Commissioning of 1 meter long Cat-6 Rj-45 patch cord, etc as required 5 Supply of following LC-SC patch cord (9/125) MMF Simplex, having connector A: LC duplex connector, ceramic ferrule, insertion typical 0.35dB. connector B: SC duplex connector, ceramic ferrule, insertion typical 0.35dB complete etc as required. 6 SITC of 10G Base SFP module SMfor 10Km (single-fiber bidirectional applications)TheSFP-10G-BXD-I and SFP-10G-BXU-I SFPs operate on a single strand of standard SMF.A SFP-10G-BXD-I device is always connected to a SFP-10G-BXU-I device with a single strand of standard SMF with an operating transmission range up to 10 km.The communication over a single strand of fiber is achieved by separating the transmission wavelength of the two devices, as depicted in Figure 2. SFP-10G-BXD-I transmits a 1330-nm channel and receives a 1270-nm signal, whereas SFP-10G-BXU-I transmits at a 1270-nm wavelength and receives a 1330-nm signal. Note in Figure 2 the presence of a Wavelength-Division Multiplexing (WDM) splitter integrated into the SFP to split the 1270-nm and 1330-nm light paths. 7 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.A) 1 Run of Cable 8 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.A) 25 mm 9 SITC of in-house server with the following specifications:a. CPU-Intel-32 Coreb. RAM-128 GBc. OS Disk- 2X960 SSDd. Data Disk- 3X2.4 SSDe. Network Port- 10G SFP+f. Management Port- Port with Licenceg. Power Supply- Dual h.VM Ware- VMware vSphere Foundation (32 Core)h. Warrranty- 3 YearsComplete with installation and go live etc as required as per the satisfaction of the client.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
31.
Railways #9985501 AOC
Bids Are Invited For Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 16; 12; 1:2; Na; Primary Dc; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 36; 32; 1:2; Na; Primary Dc; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 48; 32; 1:2; Na; Primary Dc; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 8; 4; 1:2; Na; Primary Dc; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 12; 8; 1:2; Na; Primary Dc; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 36; 32; 1:2; Na; Dr Site; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 12; 8; 1:2; Na; Dr Site; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 48; 20; 1:2; Na; Primary Dc; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 32; 16; 1:2; Na; Primary Dc; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 8; 4; 1:2; Na; Dr Site; 100 , Virtual Machine (Compute) - Public Cloud; Red Hat Enterprise Linux; 16; 12; 1:2; Na; Dr Site; 100 , Virtual Machine (Compute) - Public Cloud; Microsoft Windows Server Or Rhel; 8; 4; 1:2; Na; Primary Dc; 100 , Virtual Machine (Compute) - Public Cloud; Microsoft Windows Server Or Rhel; 16; 8; 1:2; Na; Primary Dc; 100 , Storage Services (Basic) - Public Cloud; Block Storage As A Service; Ssd; 10000 , Storage Services (Basic) - Public Cloud; Block Storage As A Service; Ssd; 5000 , Vpn Gateway - Site To Site Connection; 1000; Upto 10 , Vpn Gateway - Point To Site Connection; 500; Up To 128 , Firewall (Virtual/ Physical) - 1000 , Public Ip - Static; 1 , Web Application Firewall - 1000 , Content Delivery Network - First 10 Tb / Month , Distributed Denial Of Services - Upto 100; 0- 10 , Log Analysis - Log Analyzer; 5 To 10 , Disaster Recovery As A Service (Draas) - Dc And Dr Both In The Cloud , Backup As A Service - Incremental Backup; Daily , Backup As A Service - Full Backup; Weekly , Support Services - Public Cloud Total Quantity :
Contract Date: Ref. Documents Contract Value : 98.43 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
36.
Home Affairs #9753086 AOC
Tender For Digitization and implementation DMR Tier II of Wireless Communication System at ’Northern Cluster, ie. Palakkad and Malappuram (2 Police Districts).-- 1 Digitization and implementation DMR Tier II of Wireless Communication System at ’Northern Cluster, ie. Palakkad and Malappuram (2 Police Districts). 2 Two slot DMR Tier II Repeater withall accessories + spare repeater 3 Duplexer 4 Exposed Dipole Antenna Array forDigital VHF Repeater 5 LMR 400 or equivalent for VHFRepeater Station(Length proposed as per survey) 6 Firewall 7 All Modem for Repeater Stations(As per survey) 8 Self-Supported Towers GBT/RTT(Height of the towershall be fixed as per radio survey/SACFA clearance/communication coverage. Specified communicationcoverage should be ensured.) minimum 8 nos for each districts 9 12V Lithium ion 300AH battery bank with suitable SMPS power management unit (Input 230V , 5A, 50HZ)(Output 12V) with battery charge controller with remote monitoring system 10 1 KVA online UPS with 6 hours backup 11 Stand by SMPS power management unit (Input 230V ,5A, 50HZ)(Output 12V) with battery charge controller power supply with remote monitoring system 12 Dispatcher System (for C/Rooms) Automatic Vehicle/Personal Location System Voice & Data Recorder ,diagnostic and Printed reports as per spec. 13 Multifunction Printer 14 Led TV-55’’ or 4K/LED wall or better 15 UPS 4KVA or better 16 Analog Audio Gateway (2 sets) 17 1KVA generator 18 DMR Tier 2Hand-Held Radio with GPS and Standard Accessories including Antenna, High capacity battery2000mAh or better -(1+1spare) DTMF keypad Belt clip with proper lock, Operating Manual and Battery charger with each radio 19 DMR Tier 2Vehicular/Mobile Radio with GPS and installation accessories including Connectors, DTMF enabled Fist Mic, 3 mtrs DC power cable, 3dB Whip Antenna with 3 Meters Cable Vehicle mounting kit Operating Manual 20 DMR Tier 2 static Radio (without GPS) installation accessories, including Connectors DTMF enabled Fist mic 3 mtrs DC power cable Static Mount Kit Operating Manual 21 3dB Whip Antenna with 3 Meters Cable 22 Coaxial cable LMR 400 or equivalent (30 meters length percable) 23 GP antenna 0dB or better 24 Laptop for radio programming 25 Software license/enabling keys 26 Radio Programming Tool Kit including all necessary hardware and software with necessary interfaces and special Kits.( 4 sets minimum & 100:1 for each districts) 27 RadioTest JIGs ( 4 sets minimum & 100:1 for each districts) 28 Primary and secondary IP Back haul over Microwave Link. 29 Back haul connectivity over leased Line /OFC from telecom service provider. Point to Point connectivity using leased line interface/ static IP. 30 Bidder to cater for all required interfaces to enable the network connectivity (As per requirement) 31 Any other equipment or spares needed for the installation(As per requirement) 32 CCTV for Security system (As per requirement) 33 Mechanical timer based automatic lighting system during night( 2 nos for each site) 34 Lightning arrestor and surge protector (As per requirement) 35 AMC 1st year for Palakkad (after warranty period) 36 AMC 2nd year for Palakkad(after warranty period) 37 AMC 3rd year for Palakkad(after warranty period) 38 AMC 1st year for Malappuram (after warranty period) 39 AMC 2nd year for Malappuram (after warranty period) 40 AMC 3rd year for Malappuram (after warranty period)
Contract Date: Mar 09, 2026 Contract Value : 10.11 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
37.
Defence #9749550 AOC
Tender For Provision Of Deficient Married Accommodation At Air Force Station Phalodi Boq (11 Aug 2025).; 1 NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00to 12.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. 2 Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch A Part I. 3 Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch A Part II 4 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch A Part III 5 Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch A Part IV 6 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch A Part V 7 Lump sum price worked out for AREA DRAINAGE as listed in Sch A Part VI 8 Lump sum price worked out for ROAD/ PATH as listed in Sch A Part VII 9 Lump sum price worked out for FENCING/GATE as listed in Sch A Part VIII 10 Lump sum price worked out for EXTERNAL ELECTRIFICATION/STP as listed in Sch A Part IX 11 Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch A Part X 12 Lump sum price worked out forRAIN WATER HARVESTING as listed in Sch A Part XI 13 Lump sum price worked out for HOT WATER SUPPLY as listed in Sch A Part XII 14 SCHEDULE A PART - XIII MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. 15 SITE CLERANCE & DEVELOPMENT 16 M & L for Surface excavation n.exc30 cm deep and averaging 20cm deep and getting out top layer arqanie soil without disturbing or destroy its texture and remove the same to a location specified and stored properly for relaying after the completion of building work exc 50m but n exc 250m complete all as specified and as directed 17 Relaying the soil excavated in Item no 13 to building site for landscaping and gardening complete all as specified and directed 18 S&F colour coaded plastic dustbins of 120 Litre capacity each in Green/Blue/Red in colour as directed by GE , made of high grade UV resistant polyethylene, suitable for segregation of biodegradable, recyclable, hazardous and sanitary waste bins to be durable , Light weight, weatherproof, easy to clean with tight fitting lids and clear identification lables complete all as specified and directed..Note :-Labelling on dustbin are as follows:a) Green color waste bin :- Bio degradable wasteb) Blue color waste bin :- Reusable/ Recycle waste c)Red color waste bin :- Land Fill waste 19 INTERNAL ELECTRIFICATION 20 S & F for wall mounted LED box type tube light fitting 4 x 20 watts industrial commercial interior batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 21 S & F forLED tube light fitting with aluminium housing 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 22 S & F forLED tube light fitting with aluminium housing 2 feet x 5 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cableof suitable sizefrom ceiling rose to fittingwith warranty option of 5 years from date of installationcomplete all as specified and as directed. 23 S & F for Decorative wall mounted luminaire made out of Nickle finesh square base with bend pipewith unbreakable globe glass suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed. 24 S & F for ceiling fan, 230 Volts, 1200 mm sweep with mian air delivary 210 CFM, service value of the fan shall be greater than 6.1 (5 star rated) as per BIS with blades, down rod & other necessary accessories with brushless direct current motor (BLDC)with remote system and electrical connections from ceiling rose to fan teriminal complete all as specified and directed. 25 S & F for energy efficient exhaust fan of 225 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing wall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 26 S & F for energy efficient exhaust fan of 300 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existingwall for fan base compelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 27 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (12) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as specified and directed 28 INCOMING(a) Copper strip busbar of suiable of capacity 200 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 12 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 13 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 29 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (07) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as directed 30 INCOMING(a) Copper strip busbar of suiable of capacity 120 Amps rating wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING(a) MCB, Single pole & neutral, 40 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 06 Nos (Officers Accn)(b) MCB, single pole & neutral, 10 amps, 240 volts, ‘C’ curve, 10 KA allcomplete as specified and as directed - 1 No (Stair case lighting)(c) Slot for fixing the three phase smart prepaid meter - 07 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 31 M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 3 mtr long 25.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 32 Note:-(i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 33 Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on displayThe meter should support open communication protocol DLMSwith the softwareNote :-(a) It should run the meter in both prepaid and postpaid mode(b) The meters should carry 5 year warranty.(c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters 34 Supplying, Fixing, Commissioning and testing of configuration of cloud based prepaid software forwith following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry.The meter data management system would capture and provide the following data:(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency.b) Monthly and quarterly billing survey data for cumulative energy and max demand, Load Survey Data, Tamper Events(ii) Communication module: The system should provide communication of energy data and bills via print, email.(iii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process.(iv) Excel Export : The system would support export of metering and billing data in excel formatNote:- (i). Software will be compatible with all makes of smart meter & shall be CERT-IN certified from CERT approved vendors for any cyber security related threat & complying as per ENC guidelines.(ii) It shall also include recurring SMS charges, Email gateway integration charges, payment gateway charges for online meter recharge etc & shall be included in quoted rate for 2 years DLP period.(iii) Provision for comprehensive operation including periodic charges of telecom operator, smart meter billing from completion of work till the competion of defect liability period of 2 years.(iv) The software would be hosted on MEITY GCC approved server. 2 years hosting costs would be included. 35 INTERNAL WATER SUPPLY 36 S & Fchromium plated fancy type Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 37 S & FChromium plated fancy type two way Angle cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 38 S & FChromium plated fancy type Bib cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 39 S & FChromium plated fancy type Pillar cock with Aerator quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 40 S & FChromium plated fancy type Sink cock(wall mounted) with Aerator long shunk quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make :Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 41 S & F Chromium plated fancy type Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete all as specified and directed.Make - Hindware/Cera/Jaquar /Kohler (GRIHA certified fittings) 42 SEWAGE DISPOSAL 43 Supply, laying and testing of 150mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 44 Supply, laying and testing of 200mm internal diameter of double wall corrugated (DWC) high density polythylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 Part-2 complete all as specified and as directed. Note : Bedding of pipe shallbe provide as per theconstruction methods ,andshall be strictly compiled as per clause No A-4 of Annex A of IS 16098 Part II 45 SEWAGE TREATMENT PLANT(STP) 46 Supplying, Design , Construction, Hydraulic testing , Commissioning and giving satisfactory trialsSTP of capacity 10KLD consisting of PMF Technology based along with the following accessories to the desired capacity of 10 KLD rated net outputcomplete as turnkey jobwith all involved electrical and mechanical componentsfor satisfactory performance of plant andrequired treated outlet waterparameters as per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023 complete all as specified and directed(a) Construction RCC tanks of following sizes:-(i) Septic tank of size - 3.70 Mtr x 1.80 Mtr x 1.50 Mtr - 01 No(ii) PMF tank of size - 4.20 Mtr x 2.80 Mtr X 1.20 Mtr- 01 No(iii) Filter Feed tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(iv)Treated Water tank of size- 1.70 Mtr x 0.80 Mtr x 1.50 Mtr - 01 No(v)Chamber between PMF & FFT of size- 0.45 Mtr x 0.45 Mtr x 0.45 Mtr - 01 No(vi) Manhole Chanber made out of brick work im CM 1:6 suitable size with FRP Manhole Covers of size - (600 mm x 600 mm) - 05 Nos 47 (b) Supply & laying of Stone course aggregate of following sizes:-(i) 8 size (200 mm) - 2.60 Cu mtr(ii)4 size (100 mm)- 2.60 Cu mtr(iii)2 size (50 mm) -2.60 Cu mtr(iv)Coarse Sand - 2.60 Cu mtr(c) Supply & laying of Bacterial Culture ( suitable for degrading sewage-1200.00 KG(d) Supply & plantingof saplings Canna Indica - 60 Nos(e) S & F for Non-clog submersible Raw sewege Pump, Single phase, 230 Volts, 50 Hz of discharge capacity 0.63 cum/ Hr @ 10 Mtr head complete- 02 Nos (01 W+ 01 S) (f) S & F for Submersible opern well pump set, Single phase, 230 Volts, 50 Hz for fresh treated water application discharge capacity 0.63 cum/ Hr@ 25 mtr head complete- 02 Nos (01 W+ 01 S) (g) Supply and install for heavy duty chemical dosing system plunger type suitable to injet solution with suitable capacity, working pressure10 Kg/cm2, comprising dosing pump coupled with 3 phase electric motor of suitable capacity, 1440 rpm assembly with Agitator in one motor , Agitator with stainless steel sweepblade duly FRP coated, FRP tank suitable capacity, complete unit mounted on heavy duty MS fabricated frame duly anti corrosive paint complete with chemical grade PVC NRV along with control panel for dosing pump suitable made of power coated MS fabricated box consting of LED indicater, digital Voltmeter, single phase preventor, high voltage, low voltage protection complete - 01 Job 48 (h) S & F for of PSF (Pressure sand filter) of size 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with multi port valve and interlinking piping - 1 Job(j) S & F for for ACF (Activated Carbon Filter) ofsize 250 mmin dia and height 1.30 mtr made out of FRP material suitable for withstand of 2.50 kg/cm2 pressure with with multi port valve and interlinking piping - 01 Job(k) S & F for UPVC Pipe of sizes 25 mm dia & 40 mm dia suitable with stand the pressure 6 kg/cm2 as required- 01 Job(l) S & F for copper conductor multistranded 3 core cable PVC insulated sheathed calble of size 2.5 Sqmm for motor connections from starter panel to motor control connector as required- 01 JobNote:-Components/ units/ Equipment/ accessory for PMF Technology based STP is as perdesign and indicative . However OEM can add/ alter/ omit the given components as per their design to achieve desired capacity and treated outlet water parameter with same technology as per E - in- Cs Branch New Dehli guidelines/ policies . 49 Supplying, Design, Construction, Hydraulic testing , Commissioning and giving satisfactory trials for Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP along with the following accessories to the desired capacity of 30 KLD rated net output, complete as turnkey job with all involved electrical and mechanical components complete all as specified and directed for satisfactory performance of plant and required treated outlet water parametersas per E-in-Cs Br Policy No 05/ 2023 dated 04 May 2023Note:- The STP shall be designed based on the inlet & outlet parameters of E-in-Cs Branch above policy.(a)Chop Whoop Winding Process MBBR/ JOHKASOU based FRP Underground Package STP inclusive of Solid Separation, Anoxic Zone, MBBR Aeration Zone & Final Sedimentation zone Tank of size 8440 mm (L) x 2430 mm (dia) Tank- 01 No(b)Chop Whoop Winding Process based FRP Underground Intermediate Water Storage Tank 10 KL of size 4310 mm (L) X 1830 mm (dia) Tank- 02 Nos(c) With socket provision on tanks as per the design of UPVC return sludge pipe 50mm dia, PVC inlet outlet pipe 150mm dia, PVC interconnection pipe of 150mm dia, UPVC 80 mm dia, FRP Straps, Turn Buckle Wire Rope, Concrete Deadman & Eye Bolts per the diameter & length of the tank, Manhole cover as per the drawing, PVC air vent nozzle of dia 50mm, manhole cover of size 550mm dia, etc- 01 Job.(d) S & F for On-Ground LLDPE Treated Water Storage Tank of 10 KL Capacity of size2550 mm dia x 2510 Height- 01 No(e)Supply installation, testing and commissioning of cubical type Relay Based Control Panel out door type madeout of 3.15 mm thick CRCA sheetof suitable size suitable for 415V, 3 Phase, 4 wire, 50 Hz AC with necessary MCCB for incoming , copper busbar, MCB for out going & necessary DOL stater etc- 01 Job 50 (f)Twin lobe rotary Air compressor capable of delivery 56 Cum /Hr suitable volume of free air at 0.27 - 0.37 kg/sq.cm, discharge Pressure 0.2 - 0.3 kg/cm2g, Noise Level at 1.5 m distance: <70-80 (DBA),Body rotter made out of EN19 with FG260 & FG-260(CI), Silencer Fabricated with MS material.driven through V belt or directly coupled though flexible coupling to a TEFC motor of suitable capacity 1440 RPM, 415 Volts, 3 Phase,50 Hz, Pressure guages-01 No,150 mm NRV -01 No, Butterfly shut off valve, air filter, cleaner etc including 3 core copper cable multistranded connection of suitable size from starter to air compressor assembly complete all as specified and directed. 02 Nos (1W + 1S)(i)UPVC pipes 80 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing works complete all as specified- 01 Job(g) Sludge Recycling Pumpof non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set suitable with Flow Rate 9.0 m3/hr, Head 10 Mtr (1.0 HP) for operation at 415Volts frequency 50Hz, 3 Phase- 01 No (1W) (For Sludge recycling in Solid Separation zone)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangements complete all as specified- 01 Job(h) Pressure Sand Filter Capacity 3.0 cum/hr made out ofFRPSide Mounted of Size: 21 x 62,workingPressure 10 PSI, Filter Media, Pebbles & Filtering Sand, PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job 51 (j)Activated Carbon Filter Capacity: 3.0 cum/hr, made out ofFRPSide Mounted of Size: 21 x 62, workingPressure 10 PSI, Filter Media: Activated Carbon 900 - 1100I/V,PVC Piping 50 mm Size (UPVC), Multiport Valve (Manual)-01 Job(k)Chlorine (Sodium Hypochlorite) Dosing Pump of Capacity 0-6 LPH, PTFE Diaphragm, single phase 230 Volts, 50 Hz including with HDPE Chlorine Dosing Drum of Capacity 100 Ltrs and necessary connections etc- 01 Job(l) Filter feed pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 3.0 m3/hr, Head 15-20Mtr (1.0 HP), suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping into PSF & ACF Filters)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii) UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrangementscomplete all as specified- 01 Job(m)Raw sewage Water transfer Pump of non clog submersible sewage pump set suitable to handle domestic sewage water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase- 02 Nos (1W+1S) (For pumping from Raw Sewage Collection tank into the Bar Screen Chamber)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor (k) Ctype shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job 52 (n) Treated Water transfer Pump of Monoblock pump set suitable to handle domestic treated water (having PH value 7 and solid particle size 20 mm) with suitable for delivery pipes with one non return valve pump set with Flow Rate 9.0 m3/hr, Head 10-15 Mtr (1.0 HP) suitable for operation at 415 Volts, 50Hz , 3 Phase (1W+1S) (For pumping from treated water zone to reuse)- 01 Job(i)The pumps shall have CI casing, motor body, Impeller & gland packing. The motor type shall be a squirrel cage induction motor with F class insulation. (ii)UPVC pipes 50 mm bore, conforms to ASTM D-1785, SH-80, with all fittings and fixtures ASTM D-2467, SH-80, laid in floors or fixed to wall, etc. including necessary fixing arrandements complete all as specified- 01 Job(o) Fine bar Screen with chamber (manual) of SS 304 for screening 5 to 6 mm particles of size 1.0 Mtr x 1.0 Mtr at inlet of MBBR tank- 01 Job 53 Note : - (i)The Package STP tank shall be made from 100% FRP Material through Chop Whoop Winding Process with compliance and certification/approval in UL 1316 from the UL LLC that is Underwriters Laboratories LLC.(ii)The FRP tanks shall be made using Isopthalic Unsaturated Polyester Resin.(iii) The Sewage Treatment Plant system shall have a valid certificate of a Green product from a reputed Government or Third party having authority to certify like CII, IGBC, Assocham or any other body having competence in issuing such certificates.(iv)The shell thickness of the tank shall be between 6.50 mm to 7.50 mm (±0.5 mm) & Dish end thickness must be 11 mm and above made only from 100% FRP material(v)Technology must be empanelled in CPHEEO Sewage Manual.(vi)Minimum Hydraulic Retention time of the total Package STP system/tank must be 22.00 hours.(vii)Minimum sludge handling should only be once a year(viii)STP must function from minimum load of 5 - 10% to 100%. (Minimum load to Peak Load)(ix)The STP must have an anoxic zone for denitrifuication(x)Minimum volume of Intermediate Water Storage tank in FRP MOC must be 10 KL(xi)Minimum volume of Treated Water Storage tank in LLDPE MOC must be 10 KL 54 Material and Labour for Motor ControlLT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. Motor Control LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete including the following accessories:-. 55 IN COMING:-(i)Copper strip busbar of 60 Amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(ii) On load change over Switch TPN of capacity 32Amps - 01 No (iii) 4 Pole MCB of capacity 5-32 Amps 10 KA breaking capacity C curve-01 No(iv)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) (v)Digital Multifunctional meter , flush mounting type with CT’sand selector switch – 01 set.OUT GOING :-(b) MCB SPN 5-32 Amps 10 KA breaking capacity C curve-04 Nos(c) DOL starter single phase with suitable relay range conforming to IS -1347(Part IV) suitable for discharge capacity 6.4 LPM ( 0.38 Cumt/Hr)at 10/25 Mtr head, 0.50 HP, including overload relay, auto timer, indicating lamps (LED) etc complete -04 Nos 56 Supply and laying fordouble wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cables of size nominal outer dia 63 mm & nominal inner dia 50 mm dia with all fittings laid in trenches / road/ nallah or fixed along wall for cable protection all as specified. 57 HOT WATER SUPPLY 58 Supply and installation,commissioning and testing at roof top of building Solar water heating system (Flate Plate Collector) based on indirect transfer of heat of capacity 100Ltr per day with electrical back up of 2 KWas per manufacturers recommednations includinghot water storage tank of capacity 300 ltrs and of 20 guage thickness stainless steel plate (having insulation of rock wool ) mineral wool 100 mm thick & cladding with aluminium sheet 24 SWG complete all as specified and directed. 59 ROAD/ PATH 60 Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed. 61 EXTERNAL ELECTRIFICATION 62 Supply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 ( 20 mm graded aggregrate ) of size 900 x 300x 100 mm thick with DANGER/ 11 KV CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work ( as required / ordered at site) complete all as specified and as directed. 63 S upply and fixingfor Cable route indicator / Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregrate) of size 900 x 300x 100 mm thick with DANGER/ LT 433 VOLTS CABLE/ MES embossing on cable route Indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required/ ordered at site) complete all as specified and as directed. 64 Supply, installation, Testing and commissioning of Outdoor type (IP 54), 03 way RMU (Ring Main Unit) 11 KV, 630 Amps, 21kA-3 Sec,IP54 SF6 insulated, One side Extensible,consisting of One No (01) motorised vacuum circuit breaker (Incomer) and Twor Nos (02) motorised vacuum circuit breaker (Outgoing) & Metering Panel Bus PT with Top LV, Battery & Battery charger, Ethernet switch & LIU (Configuration VVV+M), inside robotically welded stainless steel 304 (Non Ferrite non Magnetic Grade) tank having min thickness 2.5 +/- 0.5mm with IP 67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of Class-0.5. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The complete RMU must be type tested for Internal arc21KA for 1 sec with AFLR Classification for Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site-repairability features such as site replaceable bushing/ coupling/ mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediately without sending the RMU to OEM Works, the Vaccum Interrupter must RMU manufacturers own make. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protectioncomplete all as specified and as directed. The unit shall include the following with all necessary standard fitting as required at site.-Make of RMU shall be limited to : ABB/ SIEMENS/ SCHNEIDER INFRASTRUCTURE(Channel partner/ System Integrator/ Authourized Partner/ License partner make RMU shall not be accepted.) 65 (a) Vacuum Circuit Breaker consist of following accessories :-(i)Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature, Graphical LCD Display(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator on the gas tank.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operation.(v)CT shall be minimum 50-100/1A ,2.5VA , 5P10 - 3 Nos. for protection(vi)CT shall be minimum 50-100/1A ,2.5VA , Class 0.5 - 3 Nos. for metering(vii)Right angle boot to be provided in each module(viii)2 x12 Volts, 26 AH Battary with Charger - 1 Set(ix)Bus VT shall be 11KV/V3/110V/V3 ,20VA , Class 0.5 - 3 Nos. for metering(x)Auxiliary VT shall be 11KV/230 ,500VA for AC supply input to Battary Charger.(xi)Capacitive voltage indication fixed type system as per IE(xii)Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm,11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. 66 (xiii)Right angle boots (push on type)(xiv)Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB.(xv)Necessay interclocking arrangement for safety and operations(xvi)One No. Operationg Handle for Manual Operation and one no. manometer(xvii)Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions.(xviii)Above switchgear shall confirm to all relevant IEC/IS Standards. 67 Supply, installation, commissioning and testing of transformer of capacity 315 KVA, confirming to IS 1180 (Part-1)- 2014 with latest amendment No 4, BEE 3 star rated, EEL 3, step down Outdoor type complete with standard fittings, HT 11 KV 3 phase LT 433 vols, 3 phase, 4 wire corrugated 7 position off circuit tape links of rating + 7.5 to -7.5% @ 2.5% by means of hand operated off load tap changer including necessary control wiringtransformer copper wound, double wound, oil immersed naturally cooled with external cooling tubes core type delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol Dyn -11 (vector group with neutral brought on secondary side (LV side) and the maximum temperature rises should not exceed 40 degree centigrade in oil and 45 degree centigrade in HV/LV winding ring measured by resistance after continuous full load run in ambient temp as per IS -2026 per transformer, IS-3639 for fitting & accessories, IS-2099 for high voltage porcelain bushings and the transformer shall be comprised with the following standard fitting with on load tappings on HT side to vary secondary voltage within limit all as per IS -1180 complete all as specified and as directed wit latest policy for following:- 68 Note 01:- (i)Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers with cable end box.(ii)Four Nos porcelain bushing suitable for 433V on LV side, complete with copper rods, nuts and washers with cable end box.(iii)Monogram plate.(iv)Oil conservator with filter and drain plug.(v)Prismatic/transparent oil gauge.(vi)De-hydrating breather with first fill of dehydrating agent (silica gel).(vii)Thermometer pocket.(viii)Air release plug.(ix) Inspection cover(x) Lifting lugs for complete transformer(xi)Top cover lifting lugs(xii) Jacking lugs(xiii) Top filter valve(xiv)Instruction plate(xv)Drain cum bottom filter valves(xvi)Earthing terminal and stud(xvii)Off load tap changer (xviii)Rating and Diagram plate(xix) Buchholz relay with alarm & trip contacts.(xx)Bi directional roller wheel -04 Nos. 69 (xxi)Marshalling box for termination of all alarm & trip controls of the transformer.(xxii)WTI (Winding temperature indicator) with alarm & trip contact(xxiii)Oil surge relay.(xxiv)Shut off valve for buchholz relay.(xxv) OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type.(xxvi)Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body.(xxvii) Necessary PCC foundation/ block masonry platform as directed by OEM. (xxviii)First filling of new and unused transformer oil, IS-335 marked.Note 02 :- (a)The rates include for supplying transformers with standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, testing and commissioning. (b) The transformer will have its initial oil filling to appropriate level (cost of oil including testing with desired dielectric strength included in supplied and installed rates, cost of PCC foundation shall be included as per manufacturer drawing) 70 Supply, fixing, installing and commissioning of octagonal Galvanised street light pole 9 mtr long, top dia 70 mm, bottom dia 155 mm, sheet thickness 3 mm and base plate dimensions 260 x 260 x16 mm thickness with door locking arrangement for provision ofterminal plate consisting ofMCB TPN 10 Amps, with necessary electrical connections including 04 Nos foundation with J type foundation bolts -04 Nos of sizeas per manufacturer design should be hot dipped galvanized andGI single arm bracket (Ornamental type) complete with door locking arrangement complete all as specified and directed.Note:- Necessary Excavation of Soil, RCC foundation as per manufacture recommendation including foundation bolts etc deemed to be included in quoted rate. 71 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (Transformer main LT Panel) 72 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:a)Copper strip busbar of 1000 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 500 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 73 OUTGOING:- (a)4 Pole MCCB 125 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No (MWO/ WO accn Bldg Panel No 1)(b)4 Pole MCCB 160 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 04 Nos (for Sgt Accn Panel No 2, 3, APFC panel & Spare)(c)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links- 01 No(d)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 74 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:- (forMWO/WO Accn LT Bldg Panel No1)Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 75 IN COMING:-a)Copper strip busbar of 250 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 125 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 76 OUTGOING:- (a)4 Pole MCCB 63 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos (forMWO accn Bldg supply- 2 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No (Street light)(c) Multifunctional Digial type Astronomical function Time switch (Astro type having longitude and latitude of Indian cities memory) 240 volts AC Single Phase - 01 No(d) Power contractor 4 Pole, 32 Amps,415 Volts, 50 Hz - 01 No (e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 77 Supply ,fabrication, installation and testing of LT Panel factory made, Type Test Assemble (TTA) Panel for working on 3 phase, 4 wire, 415 Volts, AC, 50Hz, cubical,Outdoor type, weather proof, water proof, dust proof, vermin proof, shock proof protectionmade out3.15 mm thick CRCA sheet of suiitable size accommodate accessories/ fittings with front and back double door opening/ lockable by the key from both side with IP 65 Protection and provn of suitable bus bar chamber and switch gear compartments for MCCB incoming & out going feeders etc with copper extension links of suitable curent carrying capacitty not less than 1.5 times the rated current carrying capacity of MCCB individual feeder supported on DMC/ Epoxy insulator including provison for termination with incoming and out going cables with cable glands. LT Panel shall be mounted on 50 x 50 x 6 mm size MS angle iron frame duly painted with two coats of black bituminus paint over a coat of red oxide primer including PCC foundation of suitable size with PCC 1:2:4 type B1(using 20 mm graded stone aggregate) .All extension link/ inter connection shall be insulated with heat shrinkable colour coaded sleeves to accomodate and including the following accessories:-(for Sgt accn Bldg Panel No 2 & 3) 78 Note:- Rate of earthwork and PCC work etc are deemed to be inclusive in this item.IN COMING:- a)Copper strip busbar of 400 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nosb)4 pole MCCB 160 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts,Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.(c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)Make :- Legrand/L&T/Schneider.(d)Digital Ammeter of range (0- 250) Amps, flush mounting type with CT’s of ratio 250/5 and selector switch – 01 set.(e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No. 79 OUTGOING:- (a)4 Pole MCCB 100 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 03 Nos ( Sgt Accn bldg supply- 02 Nos & Spare)(b)4 Pole MCCB 32 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links - 01 No(e)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter - 01 No. 80 Material and labourfor Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for cable protection and making good as existing complete all as specified and as directed. 81 Material and labourfor maintenance free Chemical earthing of technology 3 mtr long20 mm dia with 250-micron Copper coating and UL listed. There should be terminal for connection of 150 x 50 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed. 82 Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii)Test Results of earthing to be submitted by the contractor for all earthings.(iii)The Contractor shall have to give written guarantee for maintenance earth resistance of less than 1.0 Ohm for the period of 10 9ten) years after certified date of completion and shall bdeposited 2000/- per earthing as security deposit for a period of Ten (10) Years.(iv)Failing to maintain resistance of earthing less than 1.0 ohm , new earthing to be provided by the contractor with out any extra cost.(v)Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. 83 EXTERNAL WATER SUPPLY 84 Supply, Laying, jointing & testing of 150mm dia (6) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed 85 Supply, Laying, jointing & testing of 100mm dia (4) Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer ofepoxy paint in outer side,suitable for push on joint(rubber gasket joint) including rubber gasket in any length with inside cement mortar lining laid in trenches/ over masonry pillarcomplete all as specified and as directed.Notes foraboveItems No 53 & 54 :- (i) Excavation & Earthwork, shall be measured and paid separately. (ii) The necessary Exise duty exemption certificate from Deputy Commissioner of respective district shall be arranged by the GE for DI pipe.The contractor shall quote the rates against these items considering Exise exemption. (iii) The quoted rate shall also be deemed to include for provision of joints and jointing material for laying pipes. For jointing ofpipe fittings or taking branch connection, provision of joints and jointing material shall be measured and paid separately. (iv) . Before laying of pipe line contractor has to submit layout diagram as per level difference and ensure proper alignment of the pipe. 86 Material and Labour for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. Y junction, double branch, cross (All socket or socket and spigot) collars, restrained joint, mechanical joint, caps & plugs 80 mm to 250 mm dia bore including cutting and jointing new positions complete all as specified and as directed 87 Material and Labour forcutting CI pipes 150 / 80mm in position for insertion and including provision of Tee branches etcfor 80/50 mm dia pipe line complete all as specified and directed 88 Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 89 Material and labour for construction of brick masonry valve pit of internal size 60cm x 60cm x 70cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 90 RAIN WATER HARVESTING 91 Supply and Fixing 150mm bore PVC slotted pipes double socketed in any length with suitable joints, laid in bore hole for recharge pit and like complete all as specified and directed 92 Boring 300mm dia for Bored cast in situ piles 16 metres in any kind of soil/soft rock and getting out and disposal of spoil to a distance 50 metres using suitable method complete all as specified and directed 93 FIRE FIGHTING SYSTEM 94 Supply and Fixing for 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 95 Supply and Fixing for 5 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 96 Supply and Fixing for 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 97 Supply and Fixing for 9 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directedMake: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 98 Supply and Fixing for Galvanized mild steel Fire bucket (Filled with dry sand & water) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter FIRE in black out side and handle with mounting bracket complete as specified and directed 99 Supply and Fixing for Galvanized mild steel Fire hook bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed 100 Supply and Fixing for Galvanized mild steel Fire Beater bracket with 3 mtr bamboo handle painted with red colourcomplete as specified and directed
Contract Date: Mar 11, 2026 Contract Value : 14.98 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
38.
Power #9736959 Technical Bid
Tender For 132 Kv Ais Sub-Station Iihm Gannaur; 1 40/50 MVA,132/33 KV Power transformer 2 132kV SF-6 Breaker along with 20% extra SF-6 Gas 3 132 kV Isolator with E/Switch 4 132kV Isolator without E/Switch 5 132KV Surge Arrester 6 132kV Post Insulators 7 132kV PT for line 8 132 kV CTs For Line & Bus Coupler (600-300-150/1-1-1 A) 9 132 kV T/F CT (250-150-100/0.577-1-1-1 A) 10 132 kV NCT (250-150-100/1A) 11 132kV C&R Panelsa) 132kV Transformer Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 12 b) 132kV Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS with Line Current Differential-cum-Distance Protection Relay for 132kV Begga-IIHM Gannaur Line 13 c) 132kV Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS for 132kV Tajpur-IIHM Gannaur Line 14 d) 132kV Bus Coupler Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 15 33 kV NCT (1000-600-400/5A) 16 33kV 1250A Vacuum Circuit Breaker for T/F Incomers 17 33kV 630A Vacuum Circuit Breaker for Line and Capacitor Banks 18 33kV CT for T/F incomers (1000-600-400/0.577-5-5-1 A) 19 33kV CT for Line and Capacitor Banks (600-300/5-1) 20 33kV 1250A Isolators without E/Switch for Incomers and Bus Sectionalizer 21 33kV 630A Isolator without E/Switch for line, C. Bank & S/Stn T/F 22 33kV 630A Isolator with E/Switch for Line and C. Bank 23 33 kV Surge Arrester 24 33kV PTs for Bus 25 33kV C&R Panelsa) 33kV Transformer I/C Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 26 b) 33kV Line Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 27 c) 33 kV Capacitor Protection and Circuit Breaker Panel (Without Auto Reclose) with SAS 28 Time synchronization equipment 29 1x10.872 MVAR 33kV Capacitor Bank along with Structure & allied equipment (i.e. Series Reactor, NCT) as per specification 30 220 V 200 AH SAN Tubular Battery 31 220 V 20/30A SMPS Battery charger 32 48V 120AH SAN Tubular Battery 33 48V SMPS Based Battery Charger 34 220 V 200 AH D.C.D.B 35 415 V LT AC Distribution Board 300 A 36 33/0.4 kV 200 KVA Station T/F 37 Stainless steel MK (250 TB) including mounting structures 38 a) 1.1 kV Copper Control Cable (un-armoured for 132 kV bays) of sizes 7Cx4mm2, 4Cx4mm2, 2Cx4mm2, 2Cx6mm2, 16Cx2.5mm2, 10Cx2.5mm2, 7Cx2.5mm2& 3Cx2.5mm2 including junction box etc. (Refer Section-6 for copper control cable specifications & Section-7 for Switchyard Erection) 39 b) 1.1 kV Copper Control Cable (un-armoured for 33kV bays) of sizes 7Cx4mm2, 4Cx4mm2, 2Cx4mm2,2Cx6mm2, 16Cx2.5mm2,10Cx2.5mm2, 7Cx2.5mm2& 3Cx2.5mm2 including junction box etc. (Refer Section-6 for copper control cable specifications & Section-7 for Switchyard Erection). 40 650/1100 Volts 3.5 core 240 mm2 aluminum power cable from Aux. T/F to ACDB 41 650/1100 Volt 3.5 core 70 mm2 aluminum cable for oil filtration set. 42 650/1100 Volt 4 core 16 mm2 copper power cable for MLDB and other cables required as per contract. 43 Fire Fighting equipments as per section-6 as under:a) 22.5Kg Capacity FE CO2 type, Trolley Mounted 44 b) 25Kg Capacity FE DCP type, Trolley Mounted 45 c) DCP 9Kg Capacity , Wall Mounted 46 d) FE CO2 6.5Kg Capacity, Wall Mounted 47 e) DCP 6Kg Capacity , Wall Mounted 48 f) Water CO2 9 Litre, Wall Mounted 49 g) Fire Buckets (12 Nos. with stand in one set) 50 Complete lighting of control room building, Switch yard area, road and street as per section 7 of the specification. a) Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications. 51 b) Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per clause 16.0 of section 7 of the specification 52 c) Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per clause 16.0 of section 7 of the specification. 53 d) Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station. 54 e) Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building. 55 Earthing Mat Material. The earth mat will be designed/ quoted for soil resistivity of 50 -m and shock duration of 1 sec. In case soil resistivity is more than 50 -m then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item. (calculation to made considering fault/shock duration of 1 sec) as per IEEE-80/relevant IS. Earthmat area 16340 m2 (approx.) 56 Computer System:- Computer system (SFF) with:Intel Core i5 processor with 11th generation or higher as specified in Section-04. 57 Multi-Function Monochromatic Laser Jet Machine (A4-25 PPM or more) with print copy and scan function, Duplexing feature, composite cartridge, ADF, A4 or larger flatbed size, Networking and wi-fi both, at least 1 input tray, 3 years on site OEM warranty. 58 Complete Substation automation system for 132/33kVsubstations including hardware (along with transducers) as defined in the technical specification, section-sub-station automation system) as per technical specification as below: Present Future 132kV 33kV 132kV 33kVT/F 2 2 (I/C) 2 2 (I/C)Line 2 2 2 2B/C 1 - - -Capacitor - 2 - 2Bus Sect. - 1 - - 59 High wall type split AC unit of 2 Ton capacity for SCADA room and specifically C&R Panel room (as per technical specification) 60 BOM FOR SAMAST COMPLIANT IEM (ON SEPARATE CUBICLE) FOR 33KV I/C: 1. (a) 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS 61 1 (b) Testing of IEM System from NABL accredited lab 62 2. Wired Indoor Meters Panel suitable for 8 meters 63 3. 16 P Industrial Grade un-managed Network switch 64 4. 4 Port line interfacing unit with patch chord 65 5. (a) Data concentrator unit (DCU)/communication Gateway (IG) with dual SIM Modem along with enclosure and accessories 66 5. (b) 3C x 2.5 Sq. mm Un-armoured cable for DCU and Switches 67 6. Cat-6 cable-unshielded 68 7. PVC conduit Pipe - 3/4 with accessories for Cat-6 cable 69 8. Armored Fibre Optic Cable (2 pair) 70 9. HDPE conduit - 40/33 with accessories 71 10. 4Cx4 Sqmm armoured cable for PT 72 11. 4Cx4 Sqmm armoured cable for CT 73 For 132 kV S/stn. HVPNL, Begga: I. Supply of 132 kV Line C&R Panel (non-SAS compliant) with Line Current Differential-cum- Distance Protection Relay to be installed at 132 kV S/stn. HVPNL, Begga (for 132 kV S/C Begga-IIHM Gannaur Line)II. The erection, testing & commissioning of C&R Panels (non-SAS compliant) at 132 kV Substation, HVPNL, Begga shall be the part of scope of successful bidder. 74 132 kV bolted type single suspension string assembly with 9 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for single Zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 75 132 kV bolted type single suspension string assembly with 9 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for twin Zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 76 132 kV bolted type single tension string assembly with 10 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp set suitable for single zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 77 132 kV bolted type single tension string assembly with 10 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp set suitable for twin zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 78 33 kV bolted type Single tension string assembly with 3 numbers ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin Zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 79 33 kV bolted type Single suspension string assembly with 3 number ANTI FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin Zebra ACSR. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators 80 Bolt less C-Type Wedge connectors matching with conductor size for single/twin zebra. 81 Copper lugs glands & PVC ferrules for control cabling. 82 Fibre cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches 83 Galvanised iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 150x25x2mm, 100x25x2mm and 75x25x2 mm and GI conduits of 50mm/100mm dia from equipment to main trench as per Section-7 of switchyard erection. 84 ACSR Zebra Conductor 85 7/3.15 GS Earthwire 86 U-bolt 20mm dia 87 Spacers for Twin Zebra conductor 88 Mandatory spares for hardware/mechanical/Electrical auxiliaries to be supplied. 10 % of the finally approved quantities for item mentioned from Sr. No. 74 to 79. 89 2.5” dia HDD/PVC pipe for 4Cx4mm2 control cable from CTs, VT to metering system as per section-5, chapter-5. 90 Item for associated structure work ‘‘Lattice type steel structure for 132kV S/Stn. Gannaur Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 132/33KV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner.. Main S/Stn. tower and beam a) Tower type BT-1 91 b) Tower type BT-3 92 c) Tower type BT-4 93 d) Tower type BT-6 94 e) Beam type BB-1 95 f) Beam type BB-2 96 g) Tower type DT-2 97 h) Tower type DT-3 98 i) Beam type DB-2 99 Equipment Structurea) 132 kV CT drg. No. HHW/ST-67 100 b) 132 kV PT drg. No. HHW/ST-67 101 c) 132 kV Surge Arrestor drg. No. HSW/ST-63R 102 d) 132kV Bus Post Insulator drg.No.HTD/ST-144 103 e) 132 kV Isolator/L&E drg. No. HTD/ST-90 R3 104 f) 132 kV NCT drg. No. HTD/ST-145 105 g) 33 kV LA drg. HTD/ST-89R 106 h) 33 kV CT drg. HTD/ST-88 107 i) 33 kV Isolator/L&E drg. HTD/ST-110 108 j) 33 kV NCT drg. HTD/ST-88 109 k) 33 kV PT drg. HTD/ST-88 110 l)132kV Cable Support Structures 111 1. EARTH WORK 1.1 Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect. 112 2. FOUNDATIONSDesign engineering & supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & approved drawings including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc. and other items not mentioned herein but required for the completion of work.The successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval.A. GANTRY TOWERSi) BT-1 113 ii) BT-3 114 iii) BT-4 115 iv) BT-6 116 v) DT-2 117 vi) DT-3 118 B. EQUIPMENT 132kV sidei) LA 119 ii) CVT/PT 120 iii)CT 121 iv) Post Insulator 122 v)Isolator & L&E 123 vi) NCT 124 33kV sidei) LA 125 ii) PT 126 iii) CT 127 iv) Isolator & L&E 128 v) NCT 129 3.CABLE SUPPORT STRUCTURE FOUNDATIONDesign, Engineering, Supply of labour, material and Construction of cable support structure foundations including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. 132kV cable support structure 130 4. BREAKER FOUNDATIONDesign, engineering, supply of labour, material for construction of breaker foundations including all associated works such as PCC, RCC, structural steel, steel reinforcement, form work etc. or any other items not specifically mentioned herein but required for completion of work as per approved equipment(s) and technical specifications.i. 132kV, SF-6 Breaker 131 ii. 33kV VCB 132 5. CAPACITOR BANK FOUNDATIONSDesign, Engg. & supply of labour, material & construction of foundations for capacitor bank with capacitor unit & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification.i) 10.872 33 kV rating Capacitor bank foundation 133 6. TRANSFORMER FOUNDATION6.1 Design, Engg., supply of labour, material and construction of T/F foundation including radiator foundations etc. complete transformer foundations including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications. In case additional foundation is/are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost to HVPNL. i) 40/50MVA 132/33kV T/F foundation. 134 6.2 Design, Engg., supply of labour, T&P and material including RCC, PCC, Reinforcement steel, misc. structural steel & other item(s) not mentioned herein but required for the completion of work as per tech. specs. for construction of below mentioned foundations.200KVA 33/0.4 KV Station T/F 135 7. CABLE TRENCHESSupply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sumpit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per attached foundation & trench layout plan, HVPNL drgs. & tech. specs. complete in all respect.i) D-type Trench 136 ii)E-type Trench 137 iii) F-type Trench 138 iv) G-type Trench 139 v) H-type Trench 140 vi) Road Crossing 141 vii) Sump pit cum pump chamber 142 8. SITE SURFACING8.1 Providing, supplying & laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and supplying & spreading 100mm thick layer of 40mm nominal size uncrushed/ crushed/broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed /broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of engineer incharge. 143 8.2 Providing, supplying & laying 100mm thick in two layers of 50mm each of 20mm nominal size uncrushed/crushed/ broken stone pebbles gravel fill including dressing, rolling & compacting complete in all respects as per specs. & instructions of engineer incharge. 144 9. ROADS & PCC PAVEMENT9.1 Supply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification..i) 6.0M wide road (Near main gate of substation) 145 ii) 3.66M wide road within substation 146 iii) PCC in front and rear of parking area of SH Building as per tech. specification and drawing HCD/SK-172. 147 10. ROAD CULVERTSDesign, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards. 148 11. BOUNDARY WALLSupply of labour, material and construction of front, C & U/C boundary walls above DPC including main gate foundations as per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R3 including DPC complete in all respect.i) 6 ft. high with GI barbed wire on angles at top. 149 ii) 4½ ft. high side wall with barbed wire on angles at top of wall. 150 iii) 4½ ft. high front wall including providing grill at top of wall & construction of gate pillars. 151 Supply of labour, T&P, material & construction of front, side & U/C boundary walls (brickwork below DPC level) as per GELO/CLO, tech. spec. & HVPNL drgs including excavation, PCC, back filling etc. complete in all respects. 152 12. RCC RETAINING WALLA. Supply of labour, material and construction of RCC retaining wall below DPC to retain the earth filling complete in all respect. Further, if L-shape retaining wall is required to be constructed as per site, the successful bidder shall develop the designs & drawings as per the soil investigation report attached in specification and shall get these checked/vetted from any professsional institute as per contract before final approval. Nothing extra shall be paid on this account. i) Difference between NGL & FGL from 2.5 to 3.5 mtr. 153 ii) Difference between NGL & FGL from 3.5 to 4.0 mtr. 154 B. Design engineering, supply of labour, material and construction of RCC T/L shaped retaining wall below DPC to retain the earth filling complete in all respect and design/drawing shall be got checked/vetted from any professsional institute as per contract before final approval. Nothing extra shall be paid on this account. i) Difference between NGL & FGL above 4.0 mtr. 155 13. U/C FENCING & GATESProviding & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached. 156 14. CONTROL ROOM BUILDINGDesign Engineering, supply of labour, material, T&P and construction of control room building complete in all respect as per tech. specs. & approved architect drgs (for reference) attached with the bid/tendered drawings including exterior weather proof paint, interior emulsion, all internal services like water supply including supply & providing of 5000ltr. capacity double layer Sintex/Diplast PVC tank, Sewerage system, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans, Finishing, Plinth protection, closed drain around the building (i.e RCC Pipe), Indoor trenches, Soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority, bore (Tubewell) (as applicable). 157 15. DRAINAGE–CUM-RAIN HARVESTING SYSTEMSupply of labour, material for construction of recharge structures with bore well(s) as per HVPN drawings & specs. complete in all respect. The location of recharge structures shall preferably be located on corner(s) of the substation and shall be got decided from the concerned Engineer in-Charge on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below). 158 16. DRAINAGE–CUM-RAIN HARVESTING SYSTEMThe successful bidder shall evolve design & drawing for drains, manholes with RCC covers and settlement tank including preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into respective bore well(s) in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be located on corner(s) of the s/stn. and shall be got decided from Engineer-incharge on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.i) Drain Section-1 159 ii) Drain Section-2 160 iii) Drain Section-3 161 iv) Road Crossing 162 v) Trench Crossing 163 vi) Sump Pit Cum Pump Chamber 164 17. RCC M-20 inclusive of labour, material, shuttering, Steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing natural ground level and the formation level to be fixed after contouring or difference on account of revised drawing issued at the time of construction and the tender drawing. However, the item of extra RCC shall not be applicable for the drawings which has to be evolved by the successful bidder. Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
39.
Civil Aviation #9682390 AOC
Bids Are Invited For Supply Of 48 Core Armoured Ofc , Supply Of 40 Mm Hdpe Pipe , Supply Of Gi Pipe Inner Dia 50 Mm And Thickness 5 Mm , Supply Of 6U Standard Network Rack , Supply Of 12U Standard Network Rack With Pdu For Installation Of Liu Network Switch , Supply Of 32U Standard Network Rack With Pdu For Installation Of Liu Network Switch , Supply Of Frp Heav Duty Chamber , Supply Of 08 Port L2 Managed Switch Industrial Grade With 02 Sfp Duplex Modules , Supply Of 64 Channel Fxo Analog Voip Gateway Analog Multiplexer , Supply Of 24 Channel Fxo Analog Voip Gateway Analog Multiplexer , Supply Of 12 Channel Fxo Analog Voip Gateway Analog Multiplexer , Supply Of 24 Chennal E And M Multiplexer Ip To Analog Audio Line Analog Gateway , Supply Of 600 Va Ups , Supply Of Ethernet To Ofc Media Converters , Supply Of Ofc Patch Cord Single Mode Sc Lc Duplex Os2 Of 3 Meters Length , Supply Of 48 Port Liu Fully Loaded With Lc Sm Pigtails Lc Adaptor And Splice Tray With Splicing And Installation , Supply Of Ofc Patch Cord Single Mode Lc Lc Duplex Os2 Of 3 Meters Length , Supply Of 12 Port Wall Mount Liu Fully Loaded Lc Sm Pigtails Lc Adaptor And Splice Tray With Splicing And Installation , Supply Cat6a 24 Ports Rj 45 Female Port Feed Through Patch Panels , Supply Of Cat6a Utp Lan Cable , Supply Of Rf Id Route Marker , Supply Of Rf Id Route Marker Locater , Supply Of Ofc Joint Box , Supply Of Physical Route Marker , Supply Of Power Socket With Switch 5Amp , Supply Of Power Cable 03 Core 1Dot5 Sq Mm , Supply Of Pvc Case With Capping 25X12x1dot5 Mm For Power , Supply Of Pvc Case With Capping 50X50x2dot5 Mm For Ofc , Supply Of 50Mm Diameter Pvc Piple , Laying And Installation Of 48 Core Optical Fibre Cable Through 40Mm Hdpe Pipe Via Horizontal Directional Drilling Hdd At Depth Of 3 To 5 Meters , Laying And Installation Of 48 Core Optical Fibre Cable Through 40Mm Hdpe Pipe Through Gi Pipe With Open Trench , Laying And Installation Of 24 Or 48 Core Optical Fibre Cable Through Duct , Fixing Of Hdpe Pipe Bye Wall Mounting And Laying Of 24 Or 48 Core Ofc , Complete Testing Of Fibre Cable End To End Of All Ofc Rings With Otdr And Submission Of Test Reports , Itc Of Switch Voip Analog Gateway Media Converters Rack Fixing Dressing At Sites Over And Integration Of All Networking Devices And Documentation - Installation And Configuration Of Switch Voip Analog Gateway Fxs Fxo And Eandm Media Converters Rack Fixing And Dressing At Sites Over All Integration Of All Networking Devices Testing Commissioning And Documentation Including Total Quantity : 10087
Contract Date: Ref. Documents Contract Value : 1.10 Crore
Boards / Undertakings / PSU No of Bidders 3
40.
Defence #9667158 AOC
Tender For Augmentation Of Facility At Mid Department At Nd Visakhapatnam; 1 SCHEDULE A PART - I [CIVIL REPAIR WORKS] 2 Taking down chowkat or frames with shutter (without taking off shutters from the frame) exc 1.5 sqm but not exc 4.0 sqm complete all as specified and directed. 3 Demolition of cement concrete [reinforced]of any description and in any position not otherwise specifically provided for and reinforcement cut as required to facilitate demolition, complete all as specified and as directed. Note: Separating of reinforcement will be measured and paid separately under relevant item. 4 Separating, scraping and cleaning of reinforcement complete all as specified and directed. Note: Demolition of concrete measured and paid separately under relevant item. 5 Demolition of cement concrete inground floors andpavings not exceeding 15 cm thickness, complete all as specified and directed. 6 Dismantling floor, hearth or wall tiling including cement mortar bedding including removal serviceable tiles to store and rubbish off the premises to a distance exc. 1.5km but not exc. 5.0km, complete all as specified and as directed. 7 Taking down cement plaster on brick or stone walls etc. including racking out joints hacking for key, scrubbing down with water etc. and rubbish off the premises to a distance exc. 1.5km but not exc. 5.0km, complete all as specified and as directed. 8 Dismantling of wall and ceiling boards (fiber, pulp, insulations, etc.) or insulation boards/slabs/ ceiling of any thickness, including cover fillets and frame, complete all as specified and directed. 9 Removing building materials etc. (other than spoil payable under Earthwork) outside MD land at GVMC designated places exc. 1.5km but not exc. 5km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed. 10 Material and labour for brickwork with Fly Ash Bricks, using old size bricks straight or curved on plan exceeding 6m mean radius, using modular bricks built in Cement Mortar 1:4, complete all as specified and directed. 11 Material and labour for dark shade/double charged/ultra charged vitrified tiles 10mm thick (square/rectangular) polished area of each tiles exceeding 0.36 Sqm but not exceeding 0.42 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles with and including backing layer of 15 mm thick screed bed in cement mortar 1:4, complete all as specified and directed. 12 Material and labour for dark shade/double charged/ultra charged vitrified tiles 10mm thick (square/rectangular) polished area of each tiles exceeding 0.36 Sqm but not exceeding 0.42 Sqm , cut to size required as in dados and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles with and including 10mm thick rendering as backing coat in cement mortar (1:4) for receiving of tiles completeall as specified and directed. 13 Supply and application of epoxy bonding agent - Nitobond EP/Epoxy bonding agent of STP Ltd (Or equivalent ) on the prepared old concrete surface using brush or roller as per manufacturer specification or as directed by Engineer-in-Charge 14 Material and labour for granolithic concrete 1:1:2 floor topping 30mm thick, laid over cement concrete subfloors etc. and finished to the surface even and fair, complete all as specified and as directed. 15 Material and labour for wear proof topping 20mm thick as specified (incorporating an approved metallic floor hardener), as per manufacturer instructions laid on concrete floors and pavings, and finished even and smooth (except metallic hardener), complete all as specified and as directed. 16 Supply only metallic Floor hardener, complete all as specified and as directed. 17 Material and labour for forming Construction joint joints 30mm deep x 10mm wide, filled with sealing compound, grade A, completeall as specified and directed. 18 Material and labour for groove cutting and filling with semi-rigid heavy duety epoxy urethane joint sealant Nitoseal PU280/Shaliseal PU PG 2K (Or Equivalent) having MAF-10%, groove size of 10mm x 10mm, complete all as directed by Engr-in-Charge. 19 Material and labour for non-skid resistant polymer flooring (epoxy self levelling topping for 4mm - Nitoflor SL 4000/Shalifloor SL of STP Ltd) (Or equivalent ), complete all as directed by Engr-in-Charge. 20 Material and labour for rendering 10mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:4 finished even and fair without using extra cement complete all as specified and as directed. 21 Material and labour for applying two coats of distemper acrylic emulsion paint with and including a coat of wall care putty and priming coat of alkali resistant primer, with and including preparation of newly plastered surfaces, all as per manufacturers instructions, complete all as specified and as directed. 22 Material and labour for complete removal of existing treatment and applying two coats of distemper acrylic emulsion paint with and including a coat of wall care putty and priming coat of alkali resistant primer, with and including preparation of the surfaces, all as per manufacturers instructions, complete all as specified and as directed. 23 Providing & fixingfalse ceiling at all heights with semi perforated 12mm thick micro tegular edgedGRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (Part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 1250 grams per sqm including both sides) comprising of main-T runners of size 15 x 32mm of length 3000mm, cross -T of size 15 x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32mm of length 600mm to form grid module of size 600 x 600mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasterns, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85 x 25 x 2mm.Galvanised iron perimeter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws.The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-Charge 24 Supply & fixing aluminium powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows and ventilators with one or more rebates of extruded built up standard tubular and other section of approved make, according to IS 1868 (Thickness of powder coating not less than 50 micron) fixed with rawl plugs, screws or fixing with clamps or with expansion hold fasteners including necessary filling up of gaps of junctions at top, bottom and sides with required EPDM / PVC/neoprene gasket etc., aluminium sections should be smooth, rust free, straight mitred and jointed mechanically wherever required including cleat angle, PVC/Neoprene gasket for glazing, panelling, aluminium anodised screws etc. complete all as specified and as directed. 25 Supply & fixing Aluminium Powder coated(minimum thickness of powder coating 50 micron) for doors, windows, ventilators andpartitions (Fixed portions) , tracked windows, sliding doors with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, complete all as specified and directed. 26 Supply & fixing powder coated aluminium door shutters, sections weight not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing and powder coated aluminium snap beading screws complete all as specified. (thickness of powder coating not less than 50 micron) as per architectural drawings and complete all as specified and directed.Note : Only aluminium shutter for the doors shall be measured in sqm.All the aluminium fittings/fixtures such as butt hinges, tower bolts, handles etc., Pre-laminated particle board and sheet glass shall be measured and paid separately under relevant items 27 Supply & fixing minimum 5.5mm thick sheet glass of ordinary quality of approved brand fixed in position with and including PVC/Neoprene gasket for glazing, glazing clips in doors, windows, partitions etc., as in squares exceeding 0.50 Sqm in each pane etc., with all required accessories, complete all as specified and directed. 28 Supply & fixing 12mm thick pre-laminated particle board, exterior grade, pre-laminated on both sides with decorative choice lamination and fixed in aluminium partitions, doors shutters etc., fixed with and including 12mm thick rubber gasket, aluminium glazing clips, complete all as specified and as directed. 29 Supply & fixing aluminium (die cast body) door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed. 30 Supply & fixing brass mortice locks, vertical type 100mm size 4 levers, complete all as specified and as directed. 31 Supply & fixing 150mm long aluminium, anodised barrel tower bolts of extruded section complete all as specified and as directed. 32 Supply & fixing floor door stopper with rubber shoe 150/140mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed complete all as specified and as directed. 33 SUB TOTAL OF SCHEDULE A PART - I 34 SCHEDULE A PART - II [INTERNAL ELECTRIFICATION] 35 Supply and fixing for Circuit / Sub main wiring with two runs of 4.0 Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100Volt along with one run of 4.0 Sqmm as earth wire, drawn through and including PVC conduit of suitable size minimum 25mm dia, concealed type, medium grade as per IS 9537 (Part 3-1983) with conduit accessories, complete all as specified and as directed. 36 Supply and fixing of vertical TPN DB suitable for MCCB 125A incomer double door type IP 43 protection sheet metal enclosure 12 ways 36 module, completeall as specified and directed by Engineer-in- charge. 37 Supply and fixing of vertical TPN DB suitable for MCCB 125A incomer double door type IP 43 protection sheet metal enclosure 08 ways 24 module, completeall as specified and directed by Engineer-in- charge. 38 Supply and fix 4 Pole MCCB 125A, 50Hz, 415V, with rupturing capacity 35kA, complete all as specified and as directed by Engineer-in-Charge 39 Supply and fixing 415V 10KA C curve miniature circuit breaker (MCB) of TP 25 to 63 amp and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and as directed. 40 Supply and fixing motorised roof air ventilator of size24 capacity 10000cfm MOC:FRP 4mm ,height 22inch, length 2000mm, width 1000mm, both side grill, rpm 960, 230 Volts, No. of blade 6, complete all as specified and as directed by Engineer in Charge. 41 Material & labour for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC 1:2:4 type B1 40mm thick cover slab with 8mm dia TMT bars @150mm c/c in both ways, suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item. 42 Supply, laying, testing and commissioning of LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 25 sq. mm, 4 core with and including cable glands, ferrules and connected accessories laid in trenches or through pipe etc., complete all as specified and as directed. 43 SUB TOTAL OF SCHEDULE A PART - II 44 SCHEDULE A PART - III [EOT CRANE] 45 Dismantling and taking down existing 2.0 ton crane, handed over to user department (necessary receipt voucher to be obtained duly signed and kept on record) and design, fabricate, supply, erect, test and commissioning of 2 Ton Capacity Single girder EOT crane push button and radio remote control system complete with span of 16 Mtrs (approx.), long travel of 50 Mtr and lift hook 12 Mtr from floor level including supply, laying of crane track rail of suitable cross section on existing gantry girder and painting the girder including auxiliary hoist, three phase, electrically operated with connected accessories like rope drum, steel wire rope, sheaves, pulleys, hydraulic thruster brake, single phase preventer, over load relay, SFU, air brake contactor, main hoist motor, micro hoist motor, cross travel motor, long travel motor, lifting hook, service platform, walk way with railing, ladders, buffers, provision safety siren for overload, load indicator, safety hooks/clamps on wall for operation and maintenance of track and DSL systemetc. completeetc. complete all as specified and directed by Engineer-in-Charge including the following :- (a) Design supply, install, test and commissioning DSL system with PVC shrouded copper bus bar for 3 phase and neutral including earth bus system all as specified suitable for 2 TON EOT Crane, complete all as specified and directed. 46 (b) Provision of LT power cable of suitable size from the panel board to crane.(c) Provision of additional push button system with interlocking wiring etc., complete as per OEM specification.(d) Main hoist speed - 3 Mtr/min (g) Main creep speed - 0.3 Mtr/min(e) long travelspeed - 5 Mtr/min(j) Long creep speed - 1 Mtr/min(f) Cross travelspeed- 10 Mtr/min(l) Cross creepspeed - 1 Mtr/minNote:-(i) All the crane/hoists are including gantry rails of suitable size DSL system with PVC shrouded copper bus bar etc. complete.(ii) All micro speed will be 1/10 of main speed by all motions.(iii) Audio visual alarm to provide to all motions, single phase preventer, over load relay, safety siren/overload alarm and ladder from floor level.(iv) All cranes & hoist shall confirm to IS 807 & IS 3177.(v) The bidder have to visit the site before quoting the tender please 47 SUB TOTAL OF SCHEDULE A PART - III 48 SCHEDULE A PART - IV [FIRE DETECTION SYSTEM] 49 Supply and fixing of Touch Screen loop Expandable up to 9 Loops addressable fire alarm panel, Panel with Sensor status indications: - Sensor status is indicated by the different colors: Color Device conditions for clean detector, Medium clean Detector, Sensor almost dirty. Dirty. 1-3 loop formats expandable upto 9 loops, upto 1000 fire detection zones 200 per panel. True peer-to-peer networking Supports intelligent/ programmable remote terminals, BMS interface. Which consists of backlit display 480 x 272 TFT 4.3”menu driven graphical touch screen IP Gateway and I/O Drivers Auto learn and Loop detection 1000 event log entries. Simplified logic delivers click and go configuration. Approved to EN54 parts 2 and 4. Quick start and protect-A working system after an auto learn is performed. Optional Peripheral expansion card UP to 254 devices per loop (Protocol dependent). Up to 188,800 devices per network. Networkable up to 200 nodes. Circuit monitoring of local panel circuits. Simple Select & Click programming. Single area false alarm management. Compatible with to given makes. Single area false alarm management facility provision of CMS / Ad-Net Software-to monitor & control the status of the FACP from the windows based system- with Visual & Sound alerts for the fire and fault condition-with 1-3 Loop formats expandable up to 9 loops. Up to 1000 fire detection zones 200 per panel completeetc., complete all as specified and directed by Engineer-in-Charge. 50 Supply and fixing addressable intelligent touch screen type fire alarm repeater panel with graphic display touch screen (480x272 TFT 4.3) 14 LED front. 2 RS 485 for connection completeetc. complete all as specified and directed by Engineer-in-Charge. 51 Supply and fixing addressable type manual call point resettable type for indoors and out doors with Fire indication completeetc. complete all as specified and directed by Engineer-in-Charge 52 Supply and fixing addressable type loop sounders alongwith inbuilt isolator completeetc. complete all as specified and directed by Engineer-in-Charge. 53 Supply and fixing addressable type loop Open Area sounders alongwith inbuilt isolator complete all as specified and directed by Engineer-in-Charge. 54 Supply and fixing 2 core x 1.5 sqmm copper armoured cable nominal cross section area FRLS PVC insulated unsheathed cable with copperconductor, multi stranded 1100 V as per IS: 1554 including wall mounting/ceiling mounting with saddles clamps screws junction boxes and required necessary earthing etc. complete all as specified and as directed by Engineer-in-charge. 55 Supply and fixing 19mm dia rigid PVC conduit complete all as directed complete all as specified and directed by Engineer-in-Charge. 56 Supply and fixing multi type multi sensor (smoke detectors/heat detectors) and IR/UV/Flame detectors as required and to be installed as per IS specifications, complete all as specified and as directed. 57 SUB TOTAL OF SCHEDULE A PART - IV 58 SCHEDULE A PART - V [AIR CONDITIONING & REFRIGERATION] 59 Supply and install hi wall split inverter units indoor/outdoor complete with cordless remote control unit and with in built air ioniser copper coil and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 2.0 TR, 230 volt, 50 Hz, single phase; including accessories nuts bolts and brackets, complete all as specified and as directed.Note : AC drain pipe from AC indoor unit to the ground level to be incorporated in the quoted rate. 60 Supply and install voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 V with output voltage stabilised at 230 V with accuracy of + 2.5% and of capacity 5 KVAincluding all accessories complete all as specified and as directed by Engineer-in-Charge. 61 Supply and fixing of single pole and neutral metal clad enclosure with 2 pin and earth plug and socket complete with one single Pole MCB of capacity 20 Amps, 240V complete all as specified and as directed by Engineer-in-charge. 62 SUB TOTAL OF SCHEDULE A PART - V 63 SCHEDULE A PART - VI [EXTERNAL FIRE FIGHTING SYSTEM] 64 Supply, lay in ducts, jetty gallery connect, test and commissioningductile Iron pressure pipe of size 150mm dia with both sides flanged and conforming to IS-8329 : 2000 in standard maximum lengths, class K-9, flange rating PN-10, fixing and lining inside with cement mortar (CML) outside with bituminous coating as per Annx `C of IS-8329 including taking down existing pipe, complete all as specified and as directed by Engineer-in-Charge. 1. Necessary fittings will be measured and paid separately as Supply only. 65 Supply only DI Specials such as Bends , tapers any type, Tee pieces, single branch, Y junction, double branch, cross, collars, caps and plugs for connecting up to 400mm bore DI Pipe all as per IS:9523, complete all as specified and as directed. Note: Fittings shall be conforming to IS 9523:2000. 66 Supply and fixing in repair Single Headed Fire Hydrant Landing Valve of Type A of size 63 mm dia confirming to IS-5290 including all Joints and Jointing Material complete all as specified and as directed. 67 Material & labour for hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed by Engineer-in-Charge. 68 Material & labour for fire hose of synthetic fiber 15 mtrs, 63mm dia as per IS 903 with IS Mark including gun metal coupling (Male and female parts), complete all as specified and as directed. 69 Supply & fix in repair fire hydrant stand posts 80mm dia 1.5 mtr height with provision of single outlet confirming to IS 908 complete all as specified and directed by Engineer-in-Charge. 70 Cutting existing CI/DI/MS Pipe line 150 mm dia & reducing to required length before laying including insertion of new tees, branches etc. for connecting of suitable size, complete all as specified and directed. 71 Supply and fixing of sluice valve, flanged of class PN 1.6 of size 150 mm dia including steel spindle with head, iron wheel, gland with gland packing, etc. and necessary fixing arrangement likerubber gasket etc., complete all as specified and as directed by Engineer-in-charge. 72 Supply, installation, testing and commissioning in repairof 150mm dia 2 way fire brigade inlets with isolation valve with instantaneous SS coupling, 63mm dia with required fittings, complete all as specified and directed by Engr-in-Charge. 73 Material & labour for Valve chamber of size 1500mm x 1500mm x 1200mm internal dimensions, with and including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, Fly ash brick work of one brick thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick(1:4) upto 150mm below GL and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 6mm thick MS plate cover complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces all as shown in TD drawing and complete all as specified and as directed by Engineer-in-Charge. 74 Supply and fix CO2 stored pressure type, fire extinguishers -9.0 Kg capacity complete with initial charge, gun metal cap, discharge hose with AB horn, nozzle, wall fixing brackets etc. confirming to IS : 15683 with ISI mark complete all as specified and as directed by Engineer-in-Charge. 75 Supply and fix light weight screw grip type CO2 fire extinguishers -4.5 Kg capacity complete with initial charge, gun metal cap, discharge hose with AB horn, nozzle, wall fixing brackets etc. confirming to IS : 15683 with ISI mark complete all as specified and as directed by Engineer-in-Charge. 76 Supply and fix dry chemical powder stored pressure type - 9 Kg capacity complete with initial charge, fund metal cap, discharge hose with nozzle wall fixing brackets etc. confirming to IS:15683 with ISI mark complete all as specified and as directed by Engineer-in-Charge. 77 Material & labour for fabrication and erection of fire stand of suitable size made out of angle iron/channel and painting with two coats of post office red colour synthetic enamel paint over a coat of red oxide primer and lettering with white paint including galvanised MS fire bucket- 03 Nos, 5 litre capacity, complete all as specified and as directed by Engineer-in-Charge. 78 SUB TOTAL OF SCHEDULE A PART - VI 79 Total Amount in Figures 80 Quoted Amount in Words
Contract Date: Apr 27, 2026 Contract Value : 2.16 Crore
Statutory Bodies & Commissions/Committees No of Bidders 8
Andhra Pradesh View Result →
41.
Defence #9519801 AOC
Tender For Improvement To Lt Network Panels Along With Associated Earthing And Allied Works At Af Stn Bagdogra; 1 Demolition and removal of existing brick tiles or terracing tiles, single layer on roofsincluding wire brushing and cleaning top surface of cement concrete, including flashings and junction of parapets, etc and removing debris/rubbish materials out side MoD land, complete all as secified and as directed. 2 Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges,complete all as specified and as directed 3 Dismantling plain or corrugated steel sheeting any gauge thickness inclding Nainital or similar pattern roof coverings, complete all as specified and as directed 4 Dismantling of wrought iron or mild steel work of any description or otherwise provided, complete all as specified and as directed. 5 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed. 6 Demolition of (Un reinforced) Cement Concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. 7 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. 8 Taking down chowkhats or frame with shutters without taking of shutters from frames not exc. 1.5 Sqm each inclding making good disturbed portion, complete all as specified and directed. 9 Taking down chowkhats or frame with shutters without taking off shutters from frames exc 1.5 Sqm but not exc 4.00 sqmeach including making good disturbed portion, complete all as specified and directed. 10 Demolition of brickwork built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as per specified and directed. 11 Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 12 Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres, complete all as specified and as directed. 13 Taking down 15mm dia bore steel tubing and connections including cleaning for re-fixing or removal from site, complete all as specified and directed. 14 Taking down 20mm dia bore steel tubing and connections including cleaning for re-fixing or removal from site, complete all as specified and directed. 15 Dismantling of Rolling Shutter including all accessories etc., complete all as specified and directed. 16 Demolition and breaking updrain pipes (Salt glazed stone ware orconcrete) of 150mm dia (Internal), set in cement mortar, including taking out from trenches if required with demolition of concrete bed and removing from the site, complete all as specified and as directed. 17 Dismantling and breaking updrain pipes (Salt glazed stone ware orconcrete) of 100mm dia (Internal), set in cement mortar, including taking out from trenches if required with demolition of concrete bed and removing from the site, complete all as specified and as directed. 18 Taking out of MCBs for existing DBs and refixing to the same in new 4 way TPN DBs, complete all as specified and as directed. 19 M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.50 mm graded stone aggregate, rough finished as in levelling course on roof, complete all as specified and directed. 20 M&L for preparation of concrete surface by cleaning of roof surfaces with wire brushes and applying 15 mm thick plaster in CM (1:4) mixed with water proofing compound as per manufacturers instruction, on roof slab, finished even and smooth without using extra cement, complete all as specified and directed. Notes : WPC shall be measured and paid seperately. 21 M&L for water proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS -3384 @0.30 litre/Sqm, by lying actetic polypropylene (APP) modified membrane prefabricated, reinforced with non-woven polyester, of 3.0 Kg/Sqm(minimum) 3mm thick with minimum 100mm side overlaps and minimum 150mm end laps and applying one coat of bituminious aluminium paint over APP membrane, complete all as specified and directed.. 22 M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated/semi corrugated/Trapezoid steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed 23 M&L for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed 24 S&F steel workin tubular trusses(Square/ rectangular) including special shaped washer etc. complete using ERW or induction butt welded tubes comfirming to IS-1161- 1998grade St-240, complete all as specified and as directed. 25 S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay) heavy for large gates, hook and pintle hinges large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. 26 M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified and as directed 27 M&L for preparation of old painted steel / iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed. 28 S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longNon asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws, complete all as specified and directed. 29 M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded aggregate) as in plinth protection/ path/ paving etc. laid in panels, finishing the top surface even and smooth without using extra cement, complete all as specified and directed. 30 Roughening surfaces of old concrete floor by picking, scrubing, sweeping clean and washing down with water to remove dust, etc.complete all as specified and directed. 31 M&L for machine cut kota stone slab 20-25mm thick as in flooring laid & jointed with cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing including 20mm thick screed bed in CM 1:4, complete all as specified and directed. 32 M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over on vertical surface of wall and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 10mm thick rendering in CM (1:4), complete all as specified and directed. 33 M&L for Vitrified Ceramic tiles light shade 8-10 mm thick, area of each tiles not exc 0.36 Sqm, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick screed bed in CM 1:6complete all as specified and directed. 34 M&L for Vitrified Ceramic tiles light shade 8-10 mm thick, area of each tiles not exc 0.36 Sqm, in skriting/vertical surface, set and jointed in neat cement slurry and pointed in white or coloured cement including 10mm thick rendering in CM 1:4, complete all as specified and directed. 35 M&L for non skid coloured ceramic floor tiles of size exc. 0.11 but n.exc.0.18 sqm each, 7-8 mm thick laid in floor set, jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6, complete all as specified and directed. 36 M&L for colour glazed ceramic wall tiles of size 450x300x7mm thick on vertical surfaces on vertical surface of wall, set and jointed in neat cement slurry and pointed in white or coloured cement to match including rendering 10mm thick in CM (1:4)complete all as specified and directed. 37 S&F powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed. 38 S&F 4 mm thick one side frosted sheet glass ordinary quality and glazing in square n.exc 0.5sqm in each pane fixed withneoprene rubber gasket in aluminium frame, complete all as specified and directed. 39 S&F powder coated aluminium (minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, powder coated aluminium fittings such as handles - 02 Nos, 100mm long hinges - 03 Nos, sliding bolt - 01 Nos, tower bolt - 02 Nos in each door, powder coated aluminium snap beading and rubber gasket, screws etc., complete all as specified and directed. Note:Glass shall be measured seprately. 40 M&L for 5.5 mm thick sheet glass ordinary quality and glazingeach pane fixed with neopunerubber gasket in aluminium frame work, complete all as specified and directed. 41 S&F Solid PVCdoor frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. tube, suppling & fixing in opening as per specification & drawings, complete all as specified and directed. 42 S&F factory made solid PVC moulded door shutters with particle board core 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face ,supplying & fixing in frame at site as per specification & drawing, complete all as specified and as directed. 43 S&F 1.25 mm thick pressed steel frame of size 105X 60 mm for door with one ore more rebate includings necessary fixing lugs, stainless steel hinges, locks strike plate etc., complete all as specified and as directed. 44 M&L for PCC 1:3:6 type C1 (using 20 mm graded aggregate) for holdfast blocks, complete all as specified and as directed. 45 S&F factory made 35mm thickflush shutters solid core construction with block board and plywood face pannel commercial type on both faces, complete all as specified and as directed. 46 S&F for 100mm long mild steel (cold rolled) butt hinges, medium weight, complete all as specified and directed. 47 S&F 150mm long extruded aluminium alloy handles, fabricated type anodised, complete all as specified and directed. 48 S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing with accessories, complete all as specified and directed. 49 S&F 150mm long aluminium anodised barrel tower bolt ofextruded section, complete all as specified and directed. 50 S&F aluminium (extruded section body) door closer hydraulically regulated, designation No 3, universal type, suitablefor door shutters 851 mm to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed. 51 M&L for welded steel wire fabric weight not exceeding 4 kg per square metre supplied and fixed complete to wood or steel members, complete all as per specified and directed. 52 M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specifed and directed. 53 M&L for 15 mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on wall, complete all as specified and directed 54 M&L for preparation of new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over 1.5mm thick wall care putty, complete all as specified and directed. 55 M&L for 15 mm thick rendering in CM (1:4) onfair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed. 56 M&L for 5mm thick rendering in cement mortar 1:3 on fair faces of concrete surfaces without using extra cement on ceiling, complete all as specified and directed 57 M&L for preparation of new plaster surface of ceiling and applying two coats of white wash, complete all as specified and directed. 58 M&L for preparation of newly plastered surfaces of wall and applying two coats of Weather Proof Exterior Emulsion paintover a coat of suitable primer on walls, complete all as specified and directed. 59 M&L for complete removal of existing treatmentand applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over prepared surfaces, complete all as specified and directed. 60 S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I, complete all as specified and directed. 61 S&F ball valve 20mm high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, complete all as specified and directed. 62 S & F in repair 20mm bore gate valves with iron wheels head screwed both ends for iron pipe and fixed, complete all as specified and directed. 63 M&L for cutting chasing pinning in making good to facing where required for concealed water tubing etc n. exc 10 cm girth in brick wall, complete all as specified and directed. 64 S&F 15mm bore unplasticised PVC pipes of pressure rating 10 kgf/Sq cm fixed to wall or ceiling or laid in floors including fittings etc., complete all as specified and directed. 65 S&F 20mm bore unplasticised PVC pipes of pressure rating 10 kgf/Sq cm fixed to wall or ceiling or laid in floors including fittings etc., complete all as specified and directed. 66 S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specifed and directed. 67 S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed 68 S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specifed and directed. 69 S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed. 70 S&F in repair PVC (SWR) vent cowl 110mm bore, complete all as specifed and directed. 71 S&F in repair 110 mm bore PVC (SWR) bends any radius, complete all as specifed and directed. 72 S&F in repair PVC (SWR) Bend radius any radius 75mm bore, complete all as specifed and directed. 73 S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore, complete all as specified and as directed 74 S&F in repair PVC (SWR) junction single, (single T) equal or unequal 75 mm bore, complete all as specified and as directed 75 S&F in repair PVC (SWR) floor trap plain with gratinghaving dia meter of out let 75mm including jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified & as directed. 76 S&F in repairs sheet glass shelf glass assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed with chromium plated brass screws, complete all as specified and as directed 77 S&F in repairs CP soap dish size 160X160X90mm fixed to wall with screw complete all as specified and directed. 78 S&F in repairs 20 mm dia aluminium anodised tubular towel rail, D type, 60 cm long between flanges fixed with brass screws complete all as specified and directed. 79 S&F in repairs 15 mm bore chromium plated fancy type angle valve with elegant knob screwed down high pressure, with crutch or butterfly handle screwed for iron pipe or for unions, complete all as specified and directed. 80 S&F in repairs 15 mm bore chromium plated fancy type bib taps with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. 81 S&F in repairs 15 mm bore chromium plated fancy type pillar tap for WHBs with capstan heads, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed, complete all as specified and directed. 82 S&F in repairs, PVC connection 15mm dia and 450 mm long with 2 Nos PTMT nuts with washers, complete all as specified and directed. 83 S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic actiontype with inlet ball valve and float, handle with & including bracket andPVC flush pipe 32 mm borecomplete all as specified. 84 S&F in repairs 600 mm x 450 mmsize beveled edge mirror of selected quality glass, 5.50 mm thick, mounted on 6mm thick AC pain buildingboard or commercial plywood and fixed to wall with wooden plugs and chromium plated brass screws & cup washers complete all as specified and as directed. 85 S&F in repairs vitreous china, Sqatting pan, Orissa Pattern, size 580 mm x 440 mm white, withintegral foot rests (excluding flushing cistern and flush pipe) and including 100mm bore ‘P’ or ‘S’ trapand provision of cement concrete bedding and connected to existing flush pipe, complete all as specified and as directed. 86 S&F in repair vitreous china wash hand basin (flat back) of size 550x400mmincluding one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector,including cutting for and pinning in ends of brackets complete all as specified and as directed. 87 Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth for foundation or for taking out or laying pipe linesetc and getting out in soft/loose soil, complete all as specified and as directed. 88 S&F in repair 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, includingdecorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps tofixed towalls, complete all as specified. 89 S&F stainless steel 304 grade clamps with ends/stops etc.including other accessoriesfor fixingarrangements of25mm mm dia curtain rodto wall, complete all as specified and as directed. 90 S&F Stainless steel 304 grade ornamental knobs for side of curtain rods includingfixingarrangements, complete all as specified and as directed. 91 S&F powder coated aluminium sliding window shutters 25 mm thick with frames (consisting of two nos glazed shutters and one no gauze shutter)3 track sliding shutters, duly fitted with neoprene beading glazing clip, locking device, heat absorbing glass 5 mm nominal thickness in glazed shutters, stainless steel wiremesh of 0.254mm nominal dia of wire and 0.95mm average width of aperature in gauzed shutter, complete all as specified and as directed. 92 S&F fabricatedpowder coated anodized aluminium grill of size 75x75 mm, using 6mm dia bars fixed to outer portion of chowkhat using U/V section runners, complete all as specified and as directed 93 M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel painting over a coat of pink primer, complete all as specified and as directed. 94 M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 95 S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5sqm in each pane, complete all as specified and as directed. 96 M&L for complete removal of existing treatment of surfaces and applying two coats of oil bound distemper over 1.5mm thick wall putty, complete all as specified and directed. 97 S&F Steel rolling shutters, thickness of laths 1.25mm, with ball bearing, as specified including top cover, anchoring rod, hasp and staple, 2 lever locks and one shop coat of primer; erected in position complete push but gear operated type with bevel gear box and crank handle, complete all as specified and directed. 98 S&F Ball bearing for rolling shutters, complete all as specified and directed. 99 Supply only intergral water proofing compound, complete all as specified and directed. 100 M&L for cement concrete 1:4:8type D-2(using 40mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. 101 S&F Mild steel framed work such as framed guard bar conforming to Fe 290,Gde-E-165, complete all as specified and directed. 102 M&L for surface dressing n. exc 15 cm deep in any type of soil, complete all as specified and directed. 103 M&L for hardcore of broken stone or aggregate of gauge n. exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. 104 M&L for75 mm thick PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in sub base etc., complete all as specified and as directed. 105 M&L for designed, pre painted coloured chequered cement concrete tiles of 300x300x25mm size set, jointed & pointed in neat cement slurry with grey cement and pigments , laid over 20mm thick screed bed in CM 1:6 finished with pigments match the shade of tiles, complete all as specifeid and directed. 106 M&L for sand cushioning to receive interlocking tiles including spreading, levelling in layers, complete all as specifeid and directed. 107 M&L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement andpigment, complete all as specifeid and directed. 108 M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping/kerb stone etc., complete all as specified and as directed. 109 M&L for excavating in post holes (or similar holes) each n.exc 0.5Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25CM, in soft and loose soil, complete all as specified and as directed. 110 M&L for cement concrete 1:2:4 type B-2 (using 40mm graded aggregate) as in foundations, filling and mass concrete in post, pillars, complete all as specified and as directed. 111 Supply only 4mm dia Chain link MS galvanised fencing, weight not exceeding 4kg per sqm, complete all as specified and directed.Note :- Weight of chainlink fencing shall be ascertained by BOO. 112 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed. 113 M&L for mild steel framed work as in doors, gates of angle iron, flat ironor other section with gusset plates, rails, braces, hold fast, pin and pintol hinges, sliding bolt etc. complete, drilled for fixing of steel sheeting or other covering doors etc. to beprepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting (exclusive of steel sheeting or other covering, running rails and guides ) and hanging; also fastening and fixing, complete all as specified and as directed. 114 S&F mild steel works as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to e-290 Gde E-165,complete all as specified and as directed. 115 Supply only mild steel round bar 10 mm dia and over for tying chain link fencingetc., complete all as specified and directed. 116 Supply screw bolts (machine made) with hexagonal or square head at one end and rounded the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5 cm but n.exc 10 cm and dia of shank 11 to 15mm and fixed in position, complete all as specified and directed. 117 M&L for 0.80mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed. 118 M&L for preparation of new or untreated steel and iron surfaces of any description not exc.10 cm in width or girth and applying two coatsof synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. 119 S&F in repairs, Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and as directed 120 M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregates as in concrete bed to drain pipes including packing under and haunching against the side of pipes,laid, jointed and tested for 150mm bore pipe, complete all as specified and as directed 121 M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregates as in concrete bed to drain pipes including packing under and haunching against the side of pipes,laid, jointed and tested for 100mm bore pipe, complete all as specified and as directed 122 M&L for salt glazed stone ware (SGSW) drain pipe, 150mm dia (Internal), grade ‘A’ laid in trenches and jointed including testing, complete all as specified and as directed. 123 M&L for salt glazed stone ware (SGSW) drain pipe, 100mm dia (Internal), grade ‘A’ laid in trenches and jointed including testing, complete all as specified and as directed. 124 Removing excavated materials (soil) to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed. 125 Returning, filling in,soft/loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed. 126 M&L for soakage well including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size of 1.80m dia and 3.00 m deep,complete all as specified and as directed. 127 M&L for 5500 ltr capacity LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc.,complete all as specified and as directed. 128 Taking down/up XLPE cable of 10 sqmm to 16 Sqmm 2 core complete with bricks & GI pipe complete all as specified and directed. 129 M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 16 Sqmm 4 Core, complete all as specified and as directed. 130 M & L for Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the galvanised iron strip 32 x 6 mm, by means nut bolt, nuts, check nuts and washer of the GI Earth strip protected by provision of GI light grade pipe 40 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion, complete all as specified and as directed.. 131 Supply, installation, testing and commissioning of 11 KV Compact Substation (CSS) out door type plinth mounted, enclosure having construction of Powder Coated/ Galvanised sheet steel of 1.6 mm thickness for non load bearing and 2.0 mm for load bearing partition sheets, and door with HRCA 4.00 mm base frame. The enclosure shall have IP54 degree of protection for HT< switchgear components and IP34 degree of protection for Transformer component. Each components will be provide with corrosion resistance and all side openable hinged door and lock and key arrangements. Heavy lifting lugs with all equipments load. Necessary danger plates outside of the CSS. The compartment illumination lamp with door operated switch shall be provided for all the compartment including necessary foundation and earth work as per manufacturers recommendation and as per the site conditions (drawing and specifications of the foundation recommended by the manufacturer to be approved by GE before commencement of thework, thequoted ratesare deemedto beinclusive ofthe same). The CSSis comprising of the followings :- 132 (Srl Item No. 131.00 Contd...)HT SWITCHGEAR:-11 KV, Non -extensible 2 WAY (1 LBS+ 1 VCB) Non- Extensable RMU compact switchgear consisting of 1 nos direct Module (LBS) and 1 No 630 Amps VCB fixed operated Manual and spring charging & closing, electrolyte grade copper busbar 11 KV/630 Amps VCB in SF6 insulated stainless steel enclosure with series trip, self-powered microprocessors numerical over current and earth fault relay protection, HT cable/Bus Bar , and one metering module with necessary CTs and PT and digital panel mounted multifunction meter with class 1.0 accuracy, comprising the following:- (Complete unit is to be installed inside CSS, protection accessories , Enclosure : Metal Clad, IP-54 Protection. Protection Relay: Self Powered Alfa numeric LCD display type. Internal arc tested for 1 sec, Fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows: -Rated Voltage - 12 KV , Rated Frequency - 50 Hz., Rated continuous current rating - 630 Amps. , Rupturing capacity of VCB --350 MVA, Rated Interrupting Current - 21 KA. , Rated making current for VCBs- 52 KA. , Rated making current for Isolators - 62 KA. , Rated short time current for 3 sec - 21 KA , Operating duty - O-3min-CO -3min.-CO , Power frequency withstand voltage - 28 KV , Impulse withstand voltage - 75 KV , Busbar rating - 120% of continuous current., Operation: Spring closing mechanism - DC motor operated with 24-volt supply, Breaker Closing - Manual & Electrical through TNC switch., Shunt Trip coil - 24 V DC, Safety Interlock Locking faciality - Required., Breaker panel indication - ON (Red) OFF (Green)Accessories: 1 No. Self Powered Relay, Mechanical counter, Space Heater with Thermostat, Fuse and ON/OFF Switch, Aux relays for remote trip/indication for PC interface etc, cubicle illumination lamp LED 5 watt retrofit type 230 V AC, T-N Switch, Anti pumping contractor etc. In addition to the above all standard fittings to be provided as per IS normsMimic Diagram: An operating mimic diagram shall be provided on the front side of each cubicle.Note: - Circuit breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM. The installations, calibration and testing of SF-6 circuit breakers will be conducted in the presence of authorised representative of OEM by the Contractor. Power pack of 230V AC, 24DC of minimum 30min backup for RMU is included in the item rate and rating of battery as described by OEM. 133 (Srl Item No. 131.00 Contd...) 11KV/0.433KV OIL TYPE TRANSFORMER OF 500KVAOil filled Type 3 phase, 50 Hz, Dyn11, ONAN type Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and Busduct inLV side complete with all accessories like buchholz relay, Oil temperature indication, windingtemperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as EEL-2 confirming to IS-1180 Part-I:2014 as per latest 4th amendment in Mar 2021 & 100%loadi/c as per specification below complete in all respects as required at site including first filling of transformer oil. Design ambient to be considered as 50 Deg C. All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only. Heat Run Test is the mandotary test for each Transformer Standard: The equipment shall confirm to the latest edition of applicable standards as follows. In case ofconflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines. oil Insulation class : K class. It should also exhibit safety against fire hazards 134 (Srl Item No. 131.00 Contd...)CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeabilityPRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noiseand vibrations. Followings should be Mandatory for any manufacturer: -a. Transformer shall be of BOLTLESS core design 135 (Srl Item No. 131.00 Contd...)LT PanelLT panel- Separate compartment for LT network inside the CSS made with 2.0mm CRCA sheet with necessary angle iron frame, dust and vermin proof, with separate openable door for LT side with necessary locking arrangement, opening for LT AL Busbar/cable entry, opening for natural air ventilation/cooling, necessary suitable range of panel mounting Multifunction Meter (6400NG), CTs etc as required with ACB 4 pole Icu=Ics=Icw(1sec) = 50kA @ 440V AC 50 Hz of breaking capacity 50KA, with EDO type, Microprocessor based overcurrent, short-circuit and earth fault release of capacity 800 Amps -01 Nos ( Main incomer of LT) and including the followings LT distribution ( i.e. LT out going).LT Outgoing: -(i) MCCB 4 pole 415-volt 50 Hz of breaking capacity 36KA, 250 Amps, Ics=100% Icu TMD overload and short circuit protection with Encapsulated double break roto technique ensures outstanding current limiting capability - 3 Nos.(ii) MCCB 4 pole 415-volt 50 Hz of breaking capacity 36KA, 200 Amps, Ics=100% Icu TMD overload and short circuit protection with Encapsulated double break roto technique ensures outstanding current limiting capability - 3 Nos.(iii) MCCB 4 pole 415-volt 50 Hz of breaking capacity 36KA, 160 Amps, Ics=100% Icu TMD overload and short circuit protection with Encapsulated double break roto technique ensures outstanding current limiting capability - 2 Nos.(iv) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. Note :- The civil work for foundation of CSS shall deemed to be included in quoted rates. 136 M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 Sqmm 3 Core complete all as specified and as directed. 137 M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmmcomplete all as specified and as directed. 138 Disconnecting and shifting of transformer of capacity 200 to 315 KVA form one sub station to another sub station by mechanically and reconnect the same, complete all as specified and directed 139 Supply,installation, commissioningandtesting complete with all accessories of transformer of 33 KV capacity 5 MVA step down, outdoor floor mounted, double copper wound,3 Phase, 50 Hz, AC,Oilimmersed, ONAN confirming to IS-2026 and IEC62770 including cooling fans, external cooling tubes/radiator cores type havingvoltage ratio 33000/11000 volts (corresponding to principal tapping ) winding delta connecting on Primary side (HV Side) and star connected on secondary side (LV side) in accordance with vector symbol Dyn11 (vector Group) with neutral brought out on LV side and looping on HV side for contact output so as to alter/vary secondary voltage by (+) 5 to (-) 15% in equal steps of 1.25% to be changed by means of (OLTC) on load Tap Changer with RTCC and AVR. Supply ,installation of RTCC panel with AVR and marshaling box . Transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability PRIME GRADE, CRGO with m4 grade or Better, Perfectly insulated and clamped to minimize noise and vibrations. 140 (Srl Item No. 139.00 Contd...)The transformer shall confirm to the latest edition of applicable standard as follows :-(i) IS-2026, for tests and tolerance of guarnteed Particulars. (ii) IS-3639 for Fitting and accessories. (iii) IS2099 for Bushing >1000V. (iii) IS-7421 for Bushing <1000 V (v) IS-1271 for Electrical insulation classified by Thermal stability. (a) Winding (iv) HV Winding -Layer/disc winding(i) LV Winding-Helical/Disc widing(b) Insulation Level (i) HV-170 (ii) LV-70 (c) Insulation level (Power frequency with Stand KVrms)(i) HV 70 (ii) LV-28 141 (Srl Item No. 139.00 Contd...)(d) Tapping Range -(+)5% to (-) 15% @1.25%(e) Tape Changer Type -On load Tap Changer +RTCC+AVR. (f) Temperature Rise (Oil/Winding) -50/55 Degree Centigrade(g) Hot spot temperature over a maximum yearly weight average ambient temp of 32 Degree Centigrade-98 Degree Centigrade(h) Termination HV/LV-Cable Box(j) Short Circuit thermal withstand time-02 seconds (k) %impedance at 75 °C clurrent and frequency (Subject to IS Tolrance) at 5 MVA base % 7.35(l) Load loss at rated current and 75 degree C (KW) (subject to IS Tolerance )at 5 MVA base -70(m) % load at which Max Efficency occurs %-33.81(n) Regulation at full load 0.8 PF%.-5.75The transformer should have following fitting and accessories :-(a) Cable Boxes on 11 KV secondary side for single core XLPE cable 3 Core 185 Sqmm(b) Outdoor 33 KV bushing insulator for connection through openconductor with sleeves.(c)Oil conservator with filling hole and cape drain valve and oil level guage.(d) Dehydrating breather wth connecting pipe first fill of dehydrating agent and oil seal.(e) Explosion relief vent mounted on tank with double diaphragm and equilliser pipe connection to conservator air space (Pressure release device)(f) Air relief plug.(g) Shut off valve between the conservator and buchholz relay.(h) Drain valve with threaded adopter. 142 (Srl Item No. 139.00 Contd...)(j) Filter valve with threaded adopter (Top and bottom).(k) Wheels (l) Rating plate and terminals marking plate.(m) Extra bushing for neutral out side the LV Side (n) Hand hole sufficient size to assess the interior of the tank.(o) First filling of the transformer oil.(p) Cover Lifting eyes.(q)Double float Buchholz relay with trip and alarm contacts.(r) 150mm dial type thermometer for winding temperature indicator having range0-12 centigrade vapor pressure type with maximum reading pointer/Max temperature indicator and resetting devicewith alarm/trip contact and additional contact for switching on the cooling fan.(s) Dial type thermometer for oiltemperature indicator with 02 sets of contacts for alarm and triphaving range 0-12 centigrade vapor pressure type with maximum reading pointer/Max temperature indicator and resetting devicewith alaram/trip contact .(t) Shut off valve between cooling tubes and tank.(u) Pressure Release Valve (PRV) with one set of trip contact.(v) Magnetic Oil gauage (MOLG) with one set of trip contact.(w) Earthing terminal for connecting earthing leadNOTE:-(i) The oil temperature and winding temperature guages shall be housed in a marshaling box made up of MS sheet as per manufacturer recommendations with hinged door and having glass front side of the box and provision for entry of cables and compression glands.(ii) The civil work for foundation of CSS deemed to be included in quoted rates.(iii) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 143 Supplying , transporting, erectioning, testing and commissiong of 33 KV, 350MVA, 630 A, 50Hzvoltage class outdoor type Vaccum Circuit Breaker for use on system voltage 33 KV. The circuit breaker and accessories shall conform to IEC-62271-100 or IS 13118 and other relevant IEC/IS standard. The circuit breaker shall be complete with terminal connection, operating mechanism, control cabinets, piping, interpole cable accessories like gland, terminal block, lugs, 02 Nos level pressure switch scale. necessary steel support structure for CB and control cabinetThe circuit breaker shall be required to performs as per technical parameters given below:- 144 (Srl Item No. 143.00 Contd...)(a) Installation - Outdoor, 3-phase, Live-Tank, Porcelain Clad, Switchyard Breaker(b) Rated Voltage - 36 KV(c) Rated Current - 630A or higher(d) Power frequency with stand voltage (KV rms)- 70 KV(e) 12/50 microsecond lighting impuls with stand voltage (KV Peak)-170 kVp(f) Rated short circuit current breaking capacity (3 Sec ) at rated voltage specified 31.5 KA(g) Control Voltage incl. trip/close coil - 30V DC (h) Spring Charging Voltage - 230VAC(j) Symmetrical interrupting capacity (KA/RMS) 31.5 KA for 3 sec(k) Rated short circuit Making Current (KAP)-80A(l)Out of phase breaking capacity (KA rms) as per IEC(m) Rated operating duty as per IEC(o) Temp rise over the design ambient temperature -As per IEC 62271-100(n)Operating Mechanism -Spring (o) Creepage distance as per IEC-900mm (p) No of trip/close coil 30 V DC-02 Nos(q) Tripping system - 30 V DCNote:-(i) Cost of supply and fix of Outdoor type Terminal Kiosk (TK) havingterminals/disconnecting-links for termination of CT/PT wiring including PT secondary fuses complete all as required at site are deemed to be included in the quoted rate.(ii) Cost of construction of foundation including construction material and necessary earth work as per manufacturer design for breaker TK complete all as required at site are deemed to be included in the quoted rate. 145 (Srl Item No. 143.00 Contd...)(2) 33KV control & relay panel indoor type for Vaccum Circuit Breaker.The panel shall be with back access double door arrangement, dust and vermin proof , IP -4X class protection and made 2mm , CRCA MS sheet powder coated finsh over one coat of red oxide primer both side operating type, including internal wiring using 1.1kV FRLS insulated multistrand cable (2.5sqmm for CT/PT and control circuit, numbered and colour coded as per IS-5578/1984 having suitable entry for cable consisting of the following:-(A) Main, Numerical Protection Relay with LCD displaying mimic bay for ON/OFF control and monitoring of feeder current. Built in as of 11 KV VCB panel relay disturbance recorderand event logger to monitor the Sequence of Events (SoE) using upto 800 event codes. The relay shall be communicable SCADA system.(i) Over current and earth fault protection with minimum pickup at low set of 5% and 1% respectively(ii) Transient/intermittent earth fault protection(iii) Phase discontinuity protection(B) Flush mounted auxillary relays for:-(i) Trip Circuit Supervision(ii) Master Trip(iii) Fuse fail (PT) supervision operated (iv) DC supervision scheme(v) Overvoltage/ undervoltagereay within max value settings with reset(C) Metering(i) Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-Vector-Meter (Acc.Cl.0.5). (ii) 01no. Multi-Function-Meter (Acc.Cl.0.5) shall be provided with LCD display for measuring current, voltage, power, power-factor and energy-parameters, Total Harmonic Distortion and Max. Demand Indication, same shall be communicable on ModBus via RS485 port. 146 (Srl Item No. 143.00 Contd...)(D) Indicating Lamp. (i) Bus-01 Isolator ON/OFF. (ii) Bus-02 Isolator ON/OFF. (iii) Line Isolator ON/OFF/EARTH(iv) CB auto trip. (v) CB ON. (vi) CB OFF. ii) CB Spring Charge. iii) Trip circuit healthy. x) DC Available LED with push-button(x) R-Y-B Phase LED Indication(E) Semaphore indicator. (i) Circuit Breaker ON, OFF. (ii) Bus-01 Isolator ON, OFF. (iii) Bus-02 Isolator ON, OFF. (iv) Line Isolator ON, OFF, EARTH(F) Control switches/Push Buttons(i) Trip-Neutral-Close Switch for Circuit Breaker Control - 01no. (ii) MCB for AC isolation - 01no. (iii) MCB for DC isolation - 01no.(iv) Heater switch with thermostat - 01no. (v) 3-pin socket with ON/OFF switch - 01no.(vi) CFL Lamp with ON/OFF switch - 01no.(G) 08-Window Annunciator with hooter and Mute, Acknowledge, Reset and Test buttons for:- (i) OC Trip Alarm(ii) EF Trip Alarm (iii) Line Differential Trip Alarm (iv) PT Fuse Failure Alarm. (v) Trip Circuit Failure. (vi) Spare.(H) Test Terminal Block for CT(j) Thecost of construction of foundation as per manufacturer design,necessary PCC work, demolition of floors/walls of substation including foundation frame (supplied by OEM) for control panel as required at site are deemed to be included in the quoted rate.(k) Power pack of 230V AC, 24 DC of minimum 30min backup.(l) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 147 Supply and installation of 33 KV, single phase, out door oil cooled CT of ratio 400/5-5 Amp, class 1.0 / 5P10, burden 15 VA ,complete all as specified and directed 148 Supply and installation of 33 KV single phase out door oil cooled PT of ratio 33 KV/rt3/110 V/rt3/110V/rt3, Class 0.5-3, Burden 50 VA – 50 VA, complete all as specified and directed 149 Supply and fixing lightning arrestor HT 33 KV, 10 KA,station class, complete all as specified and directed. 150 Supply and fixing HT 33 KV out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators and with earth switch upto 400 Amps, complete all as specified and directed. 151 Supply ,install ,testing and commissioning of outdoor type floor mounted metal clad 11 kV ,VCBhaving rupturing capacity 350 MVA of rating upto 630 Amp. with 1 way - ICOG, totally enclosed fully interlocked draw out type breaker as per IEC 62271-100 & IEC 62271-200, as amended upto date and additional specification, having capacities as mentioned below, single break, trip free mechanism, manual/spring charging and auto/ manually closing breaker suitable for use on 11 KV, 3 phase, 50Hz AC supply with short circuit fault level of 25 kA for 0.1 sec , Panel shall be full internal arc tested i.e. in all three chambers at 25 kA for 0.1 sec for safety purpose (AFLR). complete with self contained, fully interlocked, breaker featured with mechanical on/off indicator with hand trip device, spring release coil, S/T coil and auxiliary switch of 6 NO+ 6 NC and equipped with following switch gears and accessories including in the connection suitable for upto 3C x 1R X 185 sqmm XLPE 11 KV cable (cable entry from Bottom side) end termination. Panel shall have micro processor based numerical relay with O/L, S/C,instantaneous, E/F. Arc flash protection to operate on Current and light for faster tripping in Cable, Bus Bar and Breaker Chembar. Panel shall have made with Aluzinc frame.The HT panel shall be compatible for applications and shall be complete with compatible hardwares. And all meters should be provided with RS 485 port with modbus. Endurance Class of VCB should be E2-M2-C2 and Number of fault breaking should be 10,000 Nos for reliability & Ease in operation. Rack-in & Rack-Out operation should be floor rolling design Make of Vacuum interrupter, circuit breaker, Panel, relays & meters shall be same. There must be a viewing window on VCB chamber door and same must be as per Internal arc test report. The basic insulation level of entire panel shall be 28 KV(RMS) / 70KV(Peak). For easy access of document like catalogue, O&M and drawing there should be QR code, pre- configured on the product Approved.Incommer - 1 Nos1 No. Vacuum Circuit Breaker - 630 A, 11 KV, 50 Hz, 3 phase, 25 kA for 0.1 sec, Breaker comes as completely sealed pole assembly to ensure long term performance Breaker control switch. 152 (Srl Item No. 151.00 Contd...)03 No. 11 KV/√3/110V/√3/110V/√3 class 1.0/3 P 50VA accuracy with 1 No. voltmeter (0- 36KV), digital type, selector switch for voltmeter and MCB for HT metering upt 11KV on incomer.1 No. 0-800A digital Ammeter with selector switch. 1 No. Trivector / MFM meter, communicable RS 485 port for MODBUS TCP- IP protocol 1 No. micro processor based with Modbus TCP-IP communication protocol numerical relay 1 set of dual core dual ratio 3CTs 125- 75/1A/1A of suitable burden and accuracy class 0.5 for metering and class 5P10 for protection.Master Trip circuit relay.Restricated earth fault protection shall be part of main protection relay. Over current IDMT & Instantaneous numerical relay with communication port suitable for Modbus TCP-IP . For the same one core of PS class to be added in CT Alarm annunciator for all i/c, tie breaker, buscoupler and outgoing HT VCBwith 12 windows with ACK, rest, test push button for transformer faults and electrical faults.Suitable space for termination upto 1No. 3 C x 185 sqmm XLPE cable outgoing feeder.1 Panel HT Board complete as required, as per single line diagram and specification. Indication Lamp shall be as required Wireless thermal sensors on Bus Bar Joints and Cable termination should be provided along with wireless Climatic sensors Suitable arrangment to capture the data and through PLC and gateway should be visible on HMI of panel, and these date should be possible to view on BMS/SCADA (if availble) Cable Box to be provided for ICOG Panel. Power pack of 230V AC 24 DC of minimum 30 minutes backup.Note :- (i) PCC platform/plinth shall be constructed as per OEM recommandation and rate for the same shall deemed to be included in quoted rates. (ii) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 153 Supply, install, testing and commissioning of 11 KV, 3ph, 50Hz, indoor type, totally enclosed metal clad switch gear, floor mounted, complete with Vacuum circuit breaker having rupturing capacity 350 MVA, 630amp, insulation level-12KV/28KV/ 75KVP, SC rating-26.3 KA for 3 Sec. IEC Ref- 62271-200 or latest updated, overload and earth fault protection, ampmeter, voltmeter and of current rating not less than 800 Amps including necessary connection with existing cables including following details specification all as specified and directed.:-(i) (a)Digital numerical relays for earth fault, over current protection and models as directed by OEM .(b) high speed trip relays.(c ) Closing coil, trip coils of 110V, DC(d) VCB will be horizontal break and horizontal draw out type.(e) VCB panel shall be suitable for local/remote control.(f) The panel will be provided with LED indicators as specified by OEM(g) Spring charging motor 0f 230V, AC(h) Auxiliary relay for transformer protection haaving buchholz alarm, Oil Temp alarm & Wdg Temp alram for Transformer feeder only(j) Relay setting after commissioning of VCB according to load/fault condition with secondary injection.(k) Provn of space heater and thermostat for heating(l) 03 No. PT 11 KV/√3/110V/√3/110V/√3 class 1.0/3 P 50VA(m) 3 Nos CT 125-75/1-1A, class1.0/5P10: 5 VA(n) Make of vaccum interupeter, circuit breaker, panels and relays shall be same make.(o) Power pack of 230V AC , 24 DC of minimum 30 minutes backup.Note :- (i) PCC platform/plinth shall be constructed as per OEM recommandation and rate for the same shall deemed to be included in quoted rates. (ii) Pre dispatch inspection at OEM factory premises shall be carried out by rep of Accepting Officer. The cost for the same is deemed to be included in quoted rates. 154 M&L for MS cross arm, bracing, supports, clamps and back plates fabricated from structural steel sections including MS nuts. Bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer all as specified and directed 155 M&L for Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) and fixing on Electric Poles with binding to Insulators with Aluminium Binding Wire as in OH Conductors including Stringing, Tightening, complete all as specified and directed 156 Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 240 sq mm, complete all as specified and directed. 157 Disconnecting and shifting of transformer of capacity 63 KVA with 33/0.433 KV bus bar form existing location to near by location by mechanically and reconnect the same, complete all as specified and directed. 158 Supply and fixing armoured copper control cable of 4 Sqmm, 4core for 33kV and 11kV VCB Circuit wiring with transformer complete all as specified all as specified and directed. 159 Supply and fixing armoured copper control cable of 2.5 Sqmm 10 core for 33KV and 11KV VCB Circuit wiring with transformer, complete all as specified and directed. 160 Supply and install steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP - 55 (11.0 metres long) including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of red oxide primer, externally from top of coping complete all as specified and as directed. (Note :- Excavation, PCC foundation and coping shall be measured and paid separately.) 161 Disconnecting and shifting of control panel form existing location to near by location, complete all as specified and as directed. 162 Supply and fixing cable jointing kit for 11 KV grade cable for indoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 sqmm, complete all as specified and directed. 163 Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 sqmm, complete all as specified and directed 164 Supply and layinggravel 63 mm, complete all as specified and directed. 165 Supply and fixing post insulators for 33 KV, complete all as specified and directed. 166 Supply and fixing pin insulators for 33 KV , complete all as specified and directed. 167 Supply and fixing disc insulators for 33 KV, complete all as specified and directed. 168 M&L earthing complete with copper earth plate electrode 600mmx600mmx3.15mm thick,thick burried directly in ground vertically to a depth not less than 3.0 mtr deep below GL with top edge of the plate not less than 2.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common saltupto 1.5 meter depth all around the earth plate and connected to earth leadof copper strip 20x3.15 mm by means of bolts, nuts, check nuts and washers of GI or steel and thimbles and other end of the earth wire connected to DB and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete .Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover.2. Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate. 3.On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values.(3) The cost ofGI earth lead & G Ipipe of 7.50 mtr length for protection of GI wire and excavation work for pit shalldeemed to be included in this item.Note:- Earthing test will be carried out and if desired result item not achieved the earthing will be redone to achieve desired result without any extra payment. 169 Supply and fixing copper strip of size 20x3mm, complete all as specified and directed. 170 M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.(NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid for). 171 M & L for Cement concrete in foundations, filling and mass concrete PCC 1:5:10 type E2 (40mm graded), complete all as specified and directed. 172 Supply and Fixing of MCB TPN40 Amps, 415 Volts, 50 Hz with 10 KA C curve complete with connection testing and commissioning, complete all as specified & directed. 173 M&L for HDPE Double wall corrugated duct pipe of size 77mm OD and 63mm ID for cable protection laid in trenches complete all as specified and directed. 174 Supply and laying un-reinforced precast cement concrete cable covers, class HV, flat, type-1 of size 300mm x 180mm x 40mm in trenches for cable protection, embossed with ELECTRIC on the top surface complete all as specified and as directed. 175 Supply and fixing electric water heater storage type steel body with MS inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC hot and cold, plug top etc. complete all as specified and directed. 176 Supplying and laying of CPVC pipes 16 mm dia SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all asspecified and directed. 177 Supply and fixing of 15mm bore bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. 178 Supply and fixing of 15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. 179 M&L for Point wiring with 4.0 Sqmm (36/0.30mm)PVC insulated andunsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thickplastic laminated sheet cover of adequate size for AC point wiring and Geyser point wiring incl 4.0 Sqmm (nominalarea) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of AC point and Geyser point at other end complete as per site requirement and all as specified & directed.Note:-Unit rate include for cutting chases for conduits and sinking for boxes andmaking good to wall, floors etc. 180 Supply and fixing sheet metal encloures with plug socket single pole and neutal with two pin and earth plug and with one MCB of 20 Amps (SP), for AC point and Geyser point, complete all as specified and directed. 181 Supply and Fixing MCB SP 20 Amp rating 240V, 10KA C curve for AC point and Geyser pointcomplete with connection testing and commissioning, complete all as specified & directed. 182 Supply and fixing 4 ways TP&N distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCBs 415 volts, 200 Amp rated bus bar with front openable cover suitable for, complete all as specified & directed. 183 Supply and Fixing of MCB TPN32 Amps, 415 Volts, 50 Hz with 10 KA C curve complete with connection testing and commissioning, complete all as specified & directed. 184 Material & Labour in replacement of Earthing complete withgalvanised steel earth plate electrode 60cmx60cmx6 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPMweightnot less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm,excavation and earth work in anytype of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete allto as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion. 185 SCHEDULE OF CREDITNote :- Amount of Rs. 3,68,536.20 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
Contract Date: Feb 10, 2026 Contract Value : 4.02 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
West Bengal View Result →
42.
Drinking Water Supply and Sanitation #9513897 Technical Bid
Tender for Kalpi Npp Water Supply Scheme District Jalaun Construction Of Intake Footbridge Wtp Oht Rising Main Distribution System And Electrical Mechanical Works Under Kalpi Npp Water Supply Scheme District Jalaun - W.T.P -Design (hydraulic and structural ), construction, (including topographical survey, geotechnical investigation and other Surveys as required) for specified capacity of WTP based on 20 Hrs. operation including inlet chamber, aeration fountain / cascade, inlet channels ,chemical building ,including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and flow measuring arrangement, clariflocculator with conventional, filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby ,safety equipment’s &EOTcrane,pressureandleveltransmitterfor pumpingplant,turbidity, TDS, PHAnalyzer,chlorineanalyzer,ROFTandLOHTforfilter house,flowtransmitterultrasonic/electromagneticatinletandoutletandFilter backwashwithentirepipingsystem , sludge handling unit and recycling of collected water from sludge , etc. complete to achieve desired perameters of clear wateras specified in tender document andin accordace letest C.P.H.E.E.O.Manual,/ltest guidline/ I.S. Codes/Govtt. Orders . All WTP scada Opratedexternal and internal electrification, laboratory building with all specified lab equipment, admin building,Sub station building (L.T./H.T. Room), Platform for Transformer,Meter Room ,chlorine Room,Staff Quarter (Type III-one Number), sanitary block with necessary water supply and drainage arrangement, campus roads (Interlocking Road/C.C.Road), landscaping( earth filling up to 115.00level including levelling and dressing of Campus )and other campus development works with rain water harvesting and garden, etc. all required works complete as per the direction of Engineer-in-Charge in Pile Foundation .The WTP shall be fully automatic prefrablybased onRapid sand gravity filter or any proven technologysuitable to treat Raw water from yamuna river throug out the year , PLC/SCADA with real time remote monitoring system and online contineuous effluent monitoring systemincluding Soil testing, Design ,S/o all labour ,material T&P etc. required for proper completion of the work as per letest IS Codes ,manuals ,instruction of engineer in charge and tender document. 2 INTAKE WELL- Supply of all materials, labour, T&P etc.as requiredforDesign and construction of Intake- well - cum - pump house of 9.0 m. internal dia. The intake well upto floor level shallbe firmly based on suitable foundation made with well sinking tecgnology including construction of coffer damand Annular raft/ well foundation , including construction of 1.20 m. wide R.C.C. balcony at plinth level, construction of Pump House made of brick masonry, duly embraced within R.C.C. column, and fitting of doors and windows, making opening arrangement at floor level of pump house (9.00 m. dia and 6 m. height)and construction of 1.20 m. wide R.C.C. balcony at Pump house floor levelincluding S.S. Rolling Shutter, steel cage hinged with locking arrangement, duly supported on steel girder. Plateform for transformer ,meter room andSubstation Building (HT pannel room,LT pannel room ) Ventilator arrangement along with fixing of required size dia. DID/F pipesand Sluice Valves- 3 Noat inlet etc. as per site requirement or as per the design. The work also includes steelrailing(grad 304 ) in three rows on both sides of pump house balcony and fixing of 0.5m. wide M.S. ladder made of 50 x 50x 6mm. angle iron ladder from floor of pump house to floor of intake well, duly supported on R.C.C.landing at suitable interval. The ladder shall run spirally inside the intake well and each landing shall be supported on R.C.C. M.S. channelpost, spaced not more than 1.5 m. interval including Construction of R.C.C. foundation block as required also include provision for dismantling and reinstatement of stone pitching,removal earth of Coffer dam to maintain flow through-out the year ,Approch roadup to Approch bridge etc up to completion of work as per insrtuction of engineer in charge and tender document . 3 The floor of pump house & balcony shall be of Kota Stone etc. complete. Frames for doors / Shutter shall be made of 50x50x5 mm. M.S. angle iron and ionized and shall be partly panelled and glazed, made of suitable steel sections, conforming to relevant BIS. The work also includes painting of all concrete surfaces with three coats of approved paint and painting of pipes, doors, windows with anticorrosive paints including design of intake well, foot bridge, pump house etc. considering seismic and other forces as per relevant BIS requirements. 4 Design and construction of 4.0 mts. wide R.C.C Foot bridge from Intake well to bank of river for length of 350 mtsminimum height of foot over bridgeslab should be equal to level of floor level of Pump House. pier of bridge in well shinking foundation minimum two Beam below deck slab with bearing support. Provision for padestal construction to rising main pipe fixing with anchor Clamping ,casing pipe for electric cables . Also including Supply& fixing ofstainless steel (gread 304) railing both sides of foot bridge , floor shall be plain chequered tiles, Statinless steel gate at entry gate of Approch bridge with locking arrangmentsup to completion of work as per insrtuction of engineer in charge and tender document . 5 Construction of R.C.C Over Head Tank (OHT)Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 and IS 11682 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911.Following capacity/StagingAll Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit asI.S. 456.Minimum depth of founditation below original ground level will be 2.0 M and in pile Foundation .Seismic effects and wind load should be taken into consideration as I.S. 1893for earthquake resistance and I.S. 875 part-III for wind load on structure. The asumed bearing capacity of soil has been taken as 8 M.T. sqm.1m wide RCC stair case from ground lavel to balcony.M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body (from manhole to tope domto bootom dome). 6 1 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. postsof 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.Electro Megnatic Flow Meter.Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consistproper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.including soil testing from govt institute as per tender document andrelevent IS codes. 7 Zone -1 1300KL/22M 8 Zone -21100KL/25M 9 Zone -3 2400KL/22M 10 Zone -4 300KL/25M 11 CONSTRUCTION OF R.C.C CLEAR WATER RESERVIOUR (C.W.R) CUM PUMP HOUSE OF VARIOUS AT DIFFERENT SITE Design & supply of allmaterial T&P etc and constructRCC CWR cum pump house offollowing capacity with HT, L.T and meter room, GI pipes railling consisting of 3 rows of 20 mm dia G.I pipe and angle iron posts of the dome periphery, S.S ladder from ground level to top of tank and inside the tank, locking device, ventilator, supply and fixing digital level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 150 mm semicircular drain around the tank, two coats of apex paint and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipes and valves etc all complete as per approved design and drawing.including soil testing from govt institute as per tender document andrelevent IS codes. 12 1200kl (MCWR) 13 Demolition of R.C.C Over Head Tank (OHT)Dismantling of ESRs of various capacities and heights using crane (10 MT capacity) and handing over M.S./ C.I./G.I. pipes, valves, bends, etc. to the Department. However taking steel reinforcement by the dismantling agency and other defung buildings like staff quarters, damaged pump house including removing dismantled materials from site and disposing them at suitable place as directed, etc. complete.Capacity of E.S.R. upto 2 lakh litres and staging upto 12 M heightZone -1 500KL/12M 14 Zone -2 -400KL/12M 15 Raw Water Rising Mains From Intake To WTPExcavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters. 16 500 mm DI K-7(yamuna river to WTP) 17 Supply of ISI mark DI K-7 S&S pipes (push on joints) with supply of allDI specials of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete 18 500 mm DI K-7(yamuna river to WTP) 19 Lowering, laying and jointing with ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position also fixing of pipe on foot over bridge, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. 20 500 mm DI K-7(yamuna river to WTP) 21 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete. 22 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm 23 -Air valves as per IS 14845 : 2000-100 mm 24 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge. 25 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm 26 Kinetic Double Air Valves-Air valves as per IS 14845 : 2000-100 mm 27 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 28 Providing reinforcementincluding cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar) 29 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 30 Sluice valve Chamber 500mm 31 Air valve Chambers -Air valves as per IS 14845 : 2000-100 mm 32 Rising MainsSupply of ISI mark DI K-7/K-9 S&S pipes (push on joints) of following with D.I. specials and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete 33 125 D.I K-9 34 200 D.I K-9 35 350 D.I K-9 36 400 D.I K-9 37 Excavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters.0 to 1.5 m depth 38 Lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. 39 125 D.I K-9 40 200 D.I K-9 41 350 D.I K-9 42 400 D.I K-9 43 Supply of following type ofDI valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. completeDouble flanged Ductile Iron Sluice valves as per IS 14840 : 2000./Air valves as per IS 14845 : 2000 including Sluice valve of Isolation 44 125 mm D.I D.F. 45 200 mm D.I D.F. 46 350mm D.I D.F. 47 400 mm D.I D.F. 48 25 mm D.I D.F. 49 50 mm D.I D.F. 50 80 mm D.I D.F. 51 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 /Air valves as per IS 14845 : 2000 52 125 mm D.I D.F. 53 200 mm D.I D.F. 54 350mm D.I D.F. 55 400 mm D.I D.F. 56 25 mm D.I D.F. 57 50 mm D.I D.F. 58 80 mm D.I D.F. 59 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 60 Sluice valve Chamber (MASONRY TYPE) 61 Air Valve Chamber 62 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 63 MS work in plain RCC incluiding bending supply wastage overlaping etc complete 64 Provision for crossing of Nalas/culvert for laying of pipe line usingsuitable dia. and length 0.60 m more than the outer width of nala, labour, T&P, necessary arrangement for diversion & pumping of water if required, barricading etc required for proper completion of work as per directions of engineer-in-charge.(up to 3.50m wide) 65 NHAI crossing by trenchless technologyProviding and laying of 700 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 400 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply distribution. 66 Railway crossing by trenchless technologyProviding and laying of 250 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 125 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply. 67 Dismantling of following type of road surfaces for laying of pipe line n work including sorting out of serviceable materials and disposal of unserviceable materials. 68 Bituminious Road 69 Cement Concrete Road 70 Re-instatement of following type of road surfaces after laying of pipe linework including supply of all materials, labour, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement. 71 Bituminious Road 72 Cement Concrete Road 73 Distribution Network .Supply of ISI Marked or its relevant code HDPE Pipes and Electrofusion specialsof follwing sizes (Dia in mm) with jointing materials, specials of sizes required during constructionas per latest I.S.Samandement upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer 74 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 75 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 76 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 77 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 78 Supply of ISI Marked or its relevant code DI K-7 Pipes and Specials of follwing sizes (Dia in mm) with jointing materials, during construction as per latest I.S amendement upto site of work included loading, unloading, cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer 79 D.I. K-7/ 200 mm 80 D.I. K-7/ 250 mm 81 D.I. K-7/ 300 mm 82 D.I. K-7/ 350 mm 83 D.I. K-7/ 400 mm 84 D.I. K-7/ 450 mm 85 Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relerelavent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. /Air Valve as per as I.S : 14845D.I. D/F Sluice valve/ Scour valve 86 25 mm. dia DI D/F 87 50 mm. dia DI D/F 88 100 mm. dia DI D/F 89 150 mm. dia DI D/F 90 200 mm. dia DI D/F 91 250 mm. dia DI D/F 92 350mm. dia DI D/F 93 Fire hydrant (80 mm dia.) 94 Excavation for pipe line trenches in Ordinary soil requiring use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50.m including supply of alllabour T&P etc complete and as per direction of engineer incharge. 95 Cartage fromstore to site of work for following size (dia in mm)HDPE pipes andElecrofusion Specialsand lowering the same into trenches and laying true to alignment and gradiant including testing of pipe lines cuttings of pipes for making up the length and making joints with electrofusion couplers, bands, tees, endcap etc. with electrofusion machinery including all jointing materials, labour, T&P etc required for proper completion of work. (excluding cost of trenching) 96 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 97 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 98 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 99 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 100 Cartage of DI K-7 pipes and specials of following size (dia in mm) , lowering them into trenches and laying true to alignment and gradiant including testing of pipe line but excluding cost of trenching including all supply of Labour T&P etc complete required for proper completion of work. 101 D.I. K-7/ 200 mm 102 D.I. K-7/ 250 mm 103 D.I. K-7/ 300 mm 104 D.I. K-7/ 350 mm 105 D.I. K-7/ 400 mm 106 D.I. K-7/ 450 mm 107 Carting of following size of Sluice Valves/ Scour Valves Fire hydrants & Air Valves from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete.D.I. D/F Sluice valve/ Scour valve/ air valve 108 25mm dia 109 50 mm dia 110 100 mm dia. 111 150 mm dia. 112 200 mm dia. 113 250 mm dia. 114 350 mm dia. 115 Fire hydrant (80 mm dia.) 116 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 117 Thrust Block 118 Supply of all matarial labour T&P etc and constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge . 119 Sluice valve chamber 120 Scour Valve Chamber 121 Air Valve chamber 122 Fire hydrant chamber 123 Flow Meter chamber 124 Provision for Nala/ Culvert crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 125 For crossing ofnalla/culvert upto 3.5 m wide(90mm dia to 110mm dia ) 126 For crossing ofRoad upto3.5 m wide(90mm to 110mm ) 127 For crossing ofRoad upto7.0. m wide(90mm to 110mm) 128 Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work 129 Interlocking tile 130 C.C Road 131 Bituminous Road 132 B.O.E Road 133 Reinstatement of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of required new matarials & reinstatement the same includng supply of labour T&P etc. required for proper completion of work. 134 Interlocking tile 135 C.C Road 136 Bitumenous Road 137 B.O.E Road 138 NEW HOUSE CONNECTIONMaking House Connectionwith Distribution main with elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe , including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches , fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. 139 In C.C. Roads 140 For 90 mm to 110mm dia 141 For 125 mm to 160 mm dia 142 For 200 mm to 250 mm dia 143 For 300 mm to 350mm dia 144 For 400 mm to 500mm dia 145 In Bitumenous Roads 146 For 90 mm to 110mm dia 147 For 125 mm to 160 mm dia 148 For 200 mm to 250 mm dia 149 For 300 mm to 350mm dia 150 For 400 mm to 500mm dia 151 In B.O.E. Roads 152 For 90 mm to 110mm dia 153 For 125 mm to 160 mm dia 154 For 200 mm to 250 mm dia 155 In C.C. Interlocking Tiles Roads 156 For 90 mm to 110mm dia 157 For 125 mm to 160 mm dia 158 For 200 mm to 250 mm dia 159 For 300 mm to 350mm dia 160 For 400 mm to 500mm dia 161 In Kacha Roads 162 For 90 mm to 110mm dia 163 For 125 mm to 160 mm dia 164 For 200 mm to 250 mm dia 165 For 300 mm to 350mm dia 166 SHIFTING OF HOUSE CONNECTIONMaking House Connection with Distribution mainwith elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe ,including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches ,fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. 167 In C.C. Roads 168 For 90 mm to 110mm dia 169 For 125 mm to 160 mm dia 170 For 200 mm to 250 mm dia 171 For 300 mm to 350mm dia 172 For 400 mm to 500mm dia 173 In Bitumenous Roads 174 For 90 mm to 110mm dia 175 For 125 mm to 160 mm dia 176 For 200 mm to 250 mm dia 177 For 300 mm to 350mm dia 178 For 400 mm to 500mm dia 179 In B.O.E. Roads 180 For 90 mm to 110mm dia 181 For 125 mm to 160 mm dia 182 For 200 mm to 250 mm dia 183 In C.C. Interlocking Tiles Roads 184 For 90 mm to 110mm dia 185 For 125 mm to 160 mm dia 186 For 200 mm to 250 mm dia 187 For 300 mm to 350mm dia 188 For 400 mm to 500mm dia 189 In Kacha Roads 190 For 90 mm to 110mm dia 191 For 125 mm to 160 mm dia 192 For 200 mm to 250 mm dia 193 For 300 mm to 350mm dia 194 Building worksSupply of all materials, labour, T& P, complete and construnction of a Half set of One No.Single Roomed staff quarters for Operator staff, pump operator, chaukidaar, pump attendent and other as per approved design in pile Foundation. 195 Zone-1 196 Zone-2 197 Zone-3 198 Zone-4 199 At wtp campus 200 Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation.For Construction of general resedential staff quarters(type-II) 1nos of 2 half set of area 57.70sqm. 201 Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation for Construction of following type of ancliary buildings Master Control Room(5x4.5x4m) 202 Construnction of Boundary Wall including supply all materials, labour, T&P etc required for proper completion of work as per Approved design in pile foundation. 203 Water Campus Zone 1 204 Water Campus Zone 2 205 Water Campus Zone 3 206 Water Campus Zone 4 207 AT wtp campus 208 Supply and fixing 3.60 M & 1.20 M wide MS Gate with pillars including fabrication and supply of steel and construnction ofboundary pillars etc complete. 209 Provide all materials, labour, T&P etc Required for proper completion of work and construct Interlocking Tiles approach road, laid dry and joints intact with coarse sand mortar including preparation of base etc 210 Water Campus Zone 1 211 Water Campus Zone 2 212 Water Campus Zone 3 213 Water Campus Zone 4 214 Construnction of Drain in Water works Campus30 x 30 cm including labour material and t&p all complete 215 Zone-1 216 Zone-2 217 Zone-3 218 Zone-4 219 Filling of earth of lower portion including levelling and dressing at water works 220 E&M works 221 RAW WATER PUMPING PLANT ATINTAKE WELL 222 Supply of Vertical type oil lubricated statically, dynamically, hydraulicallybalancedturbinepumpcapableofdischargingat980 rpm the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260with 2% NiCi with CF8M impeller running at 980 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer, Suction bell mouth, strainer, oil tube and 24mtr/suitablelengthcolumnassembly,withverticalSolidshaft Squirrel cage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuousratedTEFCIP-55withClassFinsulation,antirotation locking arrengementfor operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 6000 LPM / 35 Mtr. HEAD / 75 HP MOTOR (2w+1s) 223 MAIN PIPING AND VALVES :- 224 Supplyof250 mm dia DIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 225 SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67 (IP-68 for field installation),protectionclasssuitableforinstallation inanypositionwithout lubrication, leakage or other operational difficulty with special grease filledgearboxandsuitableformanualoperationforemergency which will automatically dis-engage on restoration of power to motor andwith10wattsinglephasespaceheaterandcontinuouslocal mechanicalpositionindicatorandindividuallyreplaceablecounter gear assembly and with two torque and four limit switches with S.S. flapandoperatedwithgeardrivencamsandofrating250Volt,5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADA operation sluice valve havingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI.Valvesare suitablefor hydrostatictestpressureof10Kg./Cm2forseatand15Kg./Cm2for body(PN-1.0)of following sizes 226 250 mm dia size at Pump delivery 227 350 mm dia size at common header 228 SupplyofDIDF manuallyoperatedsluicevalvehavingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass 229 Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -3 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 3 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -1 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot 230 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size 231 Dismantling joint 200 mm dia size at pump delivery 232 Dismantling joint 350 mm dia size at common header 233 Suitable capacity heavy duty handoperatedoverheadTravelling(HOT)crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 234 MOTOR CONTROL CENTER (MCC) PANEL :-Singlefront,Indoor&floormounted,cubicaltypePanelfactory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust andvermin proof IP-54 /IS:2147, consideredEarth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 3 No, Digital Amperemeter0-1000A -3Nos,CTFormeterResinCastCL- 1000A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION200 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 3 No, Spreader Links & Extended ROH for MCCB - 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 235 SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ampere meter, Voltmeter, indicating lamp6Nos,LEDON/OFFtypeandStart/Stoppushbuttonand InstrumentFuses,suitabletoSCADAoperationwithRS485Port rating capacity 75 HP / 55 KW 236 Supply & laying of 1.1KV grade XLPE insulated armured multi strand copperconductorcableof3Cx50sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I/ IS :7098 P-I) 237 Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm 238 Earthing with GI earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories, and providing masonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 :2018 239 Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) 240 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 241 Supply of CE/UL Certified Surge protector for control panel 242 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of 400 Amp 243 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. Compact SolarLED Street Light- 60W/12V/27Ah with GI pole 244 Internal & External electrification of Pump house :- 245 Twin tube light covered LED 20 Watt 246 450 mm dia exhaust fan 247 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 248 CompletewiringofPumphouse with1.5 Sqmm& 2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 249 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 250 INSTRUMENTATIONWORKS AT INTAKE WELL 251 Supply of CE/UL Full Bore Electromagnetic Flow Meter of approved makeoffollowing dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SS AISI 316L /Hastelloy C276/Tantalum,LiningMaterial:Hard Rubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard&Rating:ANSI150,Coilhousing:SSAISI304/Carbon Steel/DieCastAluminium, withanticorrosivepaint &provide completelysealed(leakproof)constructionasperrequirement ‘of IEC60529,Accuracy:+0.5%M.V.-velocity0.3to10m/s, Transmitter/signaconvertor Enclosure :DieCast Aluminium, Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable(size - 350 mm dia at common header) 252 SupplyofCE/ULCertifiedpressuretransmitterCEmarkdwith following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 253 Supply of CE/UL cirtified ofRadar level transmitter CE marked with following technical parametersand Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 254 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and PowerSupplywithanalogandDigitalParameterandfeaturesas specified tostoreandtransmitdataonGSMbackbone,RTU/PLC designedwithlogictotansferdataatmultiplestationsandalso compatible for satellite communication. 255 Control panel with IP 54 Protection, Industrial grade forall equipment and 24V and power supply 256 GSM/GPRS based wirelesscommunicationwith 4G modem for RTU/PLC Capable to transfer and gather data from remotesites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge 257 CE & UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters 258 CE/UL Certified Intelligent energy meters 259 Complete cabling for instrumentation works with power cabeling to panel of automation 260 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. 261 Installation, testing and comissioning of pumping plant & associated allequipmentsasperapproveddrawingshallbedonebybidder includingchequerredplateandpaintingofpumpingplant&main piping-valves. 262 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 263 CLEAR WATER PUMPING PLANT AT MCWR 264 SupplyofVerticaltypeselfwaterlubricatedstatically,dynamically, hydraulically balanced turbine pump capable of discharging at 1450 rpm thefollowingdutyconditionasgivenbelowduetoallcauseswith surfacedischargeheadconfirmingtoIS:1710andasamendedason datewithaccessoriesasperIS5120/1977(Reconfirmed2011)andas amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260 with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer,Suctionbellmouth,strainer,oiltubeand05mtr/suitable lengthcolumnassembly,withverticalSolidshaft Squirrelcage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class F insulation, anti rotation locking arrengement for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 5300 LPM / 50 Mtr. HEAD / 100 HP MOTOR (2w+2s) 265 MAIN PIPING AND VALVES :- 266 SupplyofDIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing 250 mm 267 SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67(IP-68 for field installation),protectionclasssuitableforinstallationinanypositionwithout lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which willautomaticallydis-engageonrestorationofpowertomotorand with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADAoperation sluice valve having Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0)of following sizes :- 268 250 mm dia size at Pump delivery 269 350 mm dia size at common header 270 Supply of DIDFmanually operated sluice valve having body Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass 271 Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -4 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 4 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -2 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot 272 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size 273 Dismantling joint 200 mm dia size at pump delivery 274 Dismantling joint 350 mm dia size at common header 275 3 Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 276 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dustandverminproofIP-54/IS:2147,consideredEarthBus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCBmicroprocessor baseed(O/C,S/C) release - 1 No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital MultifunctionMeter-1No,DigitalVoltmeter0-500V-1No,Digital Amperemeter0-400A -3Nos,CTFormeterResinCastCL- 200A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, ControlMCBSP6A,10KA-3Nos,CTShortingTerminal-4Nos, Neutral Link - 1 No.OUTGOING SECTION250 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 4 No, Spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 277 SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offeredforoperationinACthreePhase50Hz(+/-5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFFtypeandStart/StoppushbuttonandInstrumentFuses, suitable to SCADA operation with RS485 Port rating capacity 100 HP / 75 KW 278 Supply & laying of 1.1KV grade XLPE insulatedarmured multi strand copperconductorcableof3Cx95sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade coppe, purity >99.97 % ISI marked as per IS:1554 P-I / IS:7098 P- I) 279 Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm 280 EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 281 Supplyingandlaying50mmX12mmG.I.stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedone by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 282 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 283 Internal & External electrification of Pump house :- 284 Twin tube light covered LED 20 Watt 285 450 mm dia exhaust fan 286 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 287 Complete wiring of Pump house with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 288 Supply of CE/UL Certified Surge protector for control panel 289 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 290 INSTRUMENTATION WORKS 291 SupplyofCE/ULFullBoreElectromagneticFlowMeterofapproved makeoffollowingdiaandspecificationscomplete: Media: Water ( Chlorinated) , Pressure : up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316L /Hastelloy C276/Tantalum,LiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, withanticorrosivepaint&providecompletely sealed (leakproof) construction as per requirement ‘of IEC 60529, Accuracy:+0.5%M.V.-velocity0.3to10m/s,Transmitter/signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category-IP68forsensor(flowtube)andIP67fortransmitter/ convertor, including Surge Arrester, cable, of of following sizes :- 292 350 mm dia. Size at common header of pumping plant 293 350 mm dia. Size at OHT outlet of zone-1 294 350 mm dia. Size at OHT outlet of zone-2 295 450 mm dia. Size at OHT outlet of zone-3 296 200 mm dia. Size at OHT outlet of zone-4 297 Supply of Electrically Motor operated actuator with positioning card and bracketforsluicevalvesuitableforSCADAoperationwithlimit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable forOHT outlet of following sizes 298 350 mm dia. Size at OHT outlet of zone-1 299 350 mm dia. Size at OHT outlet of zone-2 300 450 mm dia. Size at OHT outlet of zone-3 301 200 mm dia. Size at OHT outlet of zone-4 302 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size 303 Dismantling joint 350 mm dia size at OHT outlet of zone-1 304 Dismantling joint 350 mm dia size OHT outlet of zone-2 305 Dismantling joint 450 mm dia size at OHT outlet of zone-3 306 Dismantling joint 200 mm dia size at OHT outlet of zone-4 307 Supply of CE/UL Certified pressure transmitter CE markd with following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 308 Supply of CE/UL cirtified ofRadarlevel transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 309 CE & UL Certified PLC/ RTU with redundent CPU & power supply in IP 54 enclosure suitable to communicate with GSMBasedmodemwith redundentCPU andPower Supply with analog and Digital Parameter and features as specified for each ZPSto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for CWR. 310 Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 311 GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for CWR & OHT 312 CE & UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 313 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligentGSMBasedmodemunit with CPU andPower Supply with analog and Digital Parameter and features as specifiedto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for OHT 314 Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 315 GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for OHT 316 CE/UL Certified Intelligent energy meters 317 Complete cabling of instrumentation equipments with power supply of panels for CWR & OHT 318 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. 319 Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done by bidder including chequerred plate and painting of pumping plant & main piping-valves. 320 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 321 11/0.44KV SUB STATION AT INTAKE WELL 322 Supply of star rated Copper wound distribution Transformer ( All the distributiontransformermustbestarratedaspernotificationof (BEE)ministryofpower,GoverenmentofIndia)offollowingrating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cablebox99.6 % & as per IS:1554 P-I / IS :7098 P - (I)from UPPCLmetering panel to H.T. Switch gear panel and panel to transformers 120 Sq.mm. size 326 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. 327 SupplyofH.T.Cableendterminationheatshrinkabletypeoutdoor joint kit 120 sq.mm. 328 Supply & laying of L.T. XLPE insulatedarmoured aluminium conductor cableof1.1KVgradeMaterial:-H4-Gradealuminium conductorofpurity>99.6%&asperIS:1554P-I/IS:7098P- (I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel and main LT panel to MCC panel of 3.5C x 300 Sq.mm. 329 Earthing with copper earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 330 Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) 331 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 332 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 333 NOC from electrical safety Dept. Govt. of UP 334 Fancing of substation in 2mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. 335 Internal & External electrification of HT & LT panel room :- 336 Twin tube light covered LED 20 Watt 337 450 mm dia exhaust fan 338 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 339 CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 340 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. CompactSolarLEDStreetLight- 60W/12V/27Ah with GI pole 341 Supplyofmicroprocessorbasedthreephasesensingpowerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor,lag/leadcapacitorswitchingstatus,alarmoutputforunder current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 100 KVAR 342 SITC of 01 No. DG Set of Capacity 180 KVA 415+ volt with AMF control Panel cabling,copper earthing etc. complete in all respect.( As per Lataest CPCB- IV Emission Norm ) 343 Installation, testing and commissioning of 11 KV /.44 KV substations includingH.T.panelandL.T.panelincludingchequeredplates,all labour T&P complete in all respect. 344 Testing of DG., Transformer, HT and LT Panel etc at Manufacturer Works 345 11/0.44KV SUB STATION AT MCWR 346 SupplyofstarratedCopperwounddistributionTransformer(Allthe distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+7.5% to - 15% @ 2.5%) temperature rise of 40 degree C inoil/45degreeCinwinding,ISImarkeddrainvalve,Dialtype Temperature gauge, OTI & WTI, marshalling box, first filling of transformer oil as per IS :335-1953, Epoxy based paint.Rating capacity - 400 KVA (1w+1s) 347 Supply of SCADA Compatible with RS 485 port 11KV,800 A, 25kA / 1 Sec, VCBIndoortypepanelHTboard,freestandingmotoroperated& withdrawaltypefabricatedfrom2mmthickCRCAsheetsteel,With copper busbar, Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection, 10 / 12-window Annunciation Panel, AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection(High oil temperature, Buchholz protection, high winding temperature, power pack 2 x 12 V,etc complete in all respect ready to use(RTU),OEM Must have BIS certificate incuding 1no incoming & 2 no outgoing VCB 348 Singlefront,Indoor&floormounted,cubicaltypeLTPanelfactory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION800 A, 50KA, TPN, ACB, EDOmicroprocessor baseed(O/C,S/C) release-2No SpreaderLinks&ExtendedROH -2No,3PhaseDigital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A -1No, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION400 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2 No, 200 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2No, spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 32KA- 2 Nos. Terminal 63A 349 Supplyandlayingof11/12KVgradeXLPEinsulatedH.T. armouerd cableasper IS:7098 / II/85,H4- Grade aluminium conductor of purity >99.6 % & as perIS:1554P-I/IS:7098P-(I)fromUPPCL meteringpaneltoH.T. Switch gear panel and panel to transformers 120 Sq.mm. size 350 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. 351 Supply of H.T. Cable end termination heat shrinkable type outdoor joint kit 120 sq.mm. 352 Supply & laying of L.T. XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 300 Sq.mm. (in 2 run for each transformer) 353 Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at WTP of 3.5C x 150 Sq.mm. 354 Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at MCWR of 3.5C x 400 Sq.mm. 355 EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 356 Supplyingandlaying50mmX12mmG.I. stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 357 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 358 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 359 NOC from electrical safety Dept. Govt. of UP 360 Fancing of substation in 2.5mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. 361 Internal & External electrification of Pump house :- 362 Twin tube light covered LED 20 Watt 363 450 mm dia exhaust fan 364 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 365 CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 366 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay&enclosure(Confirms to IEC:60947-1&IEC: 60947-6-1)of 630 Amp 367 Supplyofmicroprocessorbasedthreephasesensing auto powerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current,insufficientcompensation,communicationinterfacewithRS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 200 KVAR 368 SITC of 01 No. DG Set of Capacity 380 KVA 415+ volt with AMF control Panel cabling, earthing etc. complete in all respect. ( As per Lataest CPCB- IV Emission Norm ) 369 Installation,testingandcommissioningof11KV/.44KVsubstations including H.T. panel and L.T. panel including chequered plates, all labour T&P complete in all respect. 370 Testing of D.G, Transformer, HT and LT Panel etc at Manufacturer Works 371 Automation of DMA 372 Flow Control Valve 373 Supplying, installing ,commissioning & testing of Flow Control Valvefor inlet with flow measuring, flow controlling, pressure monitoringandweb based with cable PLC etc Complete.Pattern Hydraulically operated self actuated flow & level control valve (either with float or altitude pilot) with downstream orifice having Ductile Iron valve body, Y - Pattern, Double Chamber, unitized actuator, Fusion bonded epoxy coating, copper control tubing with Latching Solenoid & Pilot operated as per design, additional speed control feature, drip tight sealing, In-line serviceable, internals stainless steel & protected diaphragm suitable for drinking water. 374 For Zone -1 375 300 mm ( for OHT Inlet) 376 250 mm ( DMA-1) 377 250 mm ( DMA-2) 378 250 mm ( DMA-3) 379 For Zone -2 380 300 mm ( for OHT Inlet) 381 200 mm ( DMA-1) 382 250 mm ( DMA-2) 383 250 mm ( DMA-3) 384 For Zone -3 385 450 mm ( for OHT Inlet) 386 300 mm ( DMA-1) 387 400 mm ( DMA-2) 388 300 mm ( DMA-3) 389 For Zone -4 390 100 mm ( for OHT Inlet) 391 200 mm ( DMA-1) 392 IsolationValve 393 Supplying, installing ,commissioning & testing of DI Isolationvalve with electric acuator for isolation of DMA flow controling with cable PLC etc Complete. 394 For Zone -1 395 250 mm ( DMA-1) 396 250 mm ( DMA-2) 397 250 mm ( DMA-3) 398 For Zone -2 399 200 mm ( DMA-1) 400 250 mm ( DMA-2) 401 250 mm ( DMA-3) 402 For Zone -3 403 300 mm ( DMA-1) 404 400 mm ( DMA-2) 405 300 mm ( DMA-3) 406 For Zone -4 407 200 mm ( DMA-1) 408 Pressure Transmitter 409 Supplying, installing ,commissioning & testing of CE/UL Certified Pressure Transmitterfor pressure monitoring web based with cable PLC etc Complete for all 10 DMA,s of All 4 Zones 410 Electromagnetic Flow Meter 411 Supplying, installing ,commissioning & testing of CE/UL Certified Electromagnetic Flow Meterfor Flow monitoringweb based with cable PLC etc Complete 412 For Zone -1 413 250 mm ( DMA-1) 414 250 mm ( DMA-2) 415 250 mm ( DMA-3) 416 For Zone -2 417 200 mm ( DMA-1) 418 250 mm ( DMA-2) 419 250 mm ( DMA-3) 420 For Zone -3 421 300 mm ( DMA-1) 422 400 mm ( DMA-2) 423 300 mm ( DMA-3) 424 For Zone -4 425 200 mm ( DMA-1) 426 Residual Chlorine Analyser 427 SITC of Chlorine Analyser with MODBUS RTU having Following specification - (a) FRC senser range 0-5 ppm (b) Analyser with RS 485 O/P suitable to OHT distribution line and compatible with SCADA system toofor all 10 DMA,s of All 4 Zones 428 Chlorine Dozer For DMA 429 SITC of SCADA Compatible Chlorination Systemfor all 10 DMA,s of All 4 Zones 430 SCADA For DMA 431 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit with CPU & Powersupply with annlog & digital parameter & featuers as specified, for each DMA to store and transmit dataon GSM backbone, RTU/PLC desgined with logic to transfer data at multiple stations with control panel as specified intender technical specifications. 432 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories include with signal enhancer antenna made for pumping plant internetcharges as specified in tender technical specification . 433 Intelligent energy meters 434 Control Panel with IP 54 Protection, Industrial Grade for all equipment. (Separate for control (24 V) and power equipments.) upto 3 pumps. 435 CE/ UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 436 CE/UL Certified 1 KVA UPS with Batteries for data backup. 437 CE/UL Certified 10 KVA UPS with Batteries for valve operation of each OHT . 438 Cabling 439 Complete Cabling for Intake well including all power & control cable of all equipments at ZPS and OHT. 440 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories . 441 MASTER CONTROL STATION (MCS) AT WTP 442 CE/UL & BIS Certified industrial grade LED MONITOR with latestconfiguration as per specification 65 443 Video call media player of same OEM 444 Core i7 10th gen Desktop/ laptop with 32 GB RAM and 256 GB SSD + 1TB HDD 445 CE/UL Certified 5 KVA UPS with Batteries required for mentioned work wih 01 hrs backup 446 Full Development version of TAGS SCADA software with costomization of software for MCS for unlimited digital and analog Input / output features as per requirements 447 CE/ULcertifiedmastercontrolroomPLCwithredundantCPU&power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect 448 CE/UL certified Field gateway agent for transfering data forMCS/control room 449 GSM/GPRSbasedwireless/Broadband/equivelentcommunicationsystem for PLC Capable to transfer and receive data & gather data from remote sitestocontrolstationsallaccessoriesincludedwithsignalenhancer,antenna along with running expences 450 CE/UL certified Firewall for network protection 451 CE/UL Certified Surge protector for Ethernet communication protection 452 CE/UL Certified industrial grade Ethernet switch 453 Mobile app facility system architecture (industries internet based & viewed through mobile apps for increasedblocal & remote visibility) 454 Canon/HP or equivalent Laser Printer 1018 or equivalent. 455 Hp or equivalent multifunctioning Laser Printer with scanner 456 BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer 457 Office furniture ( office table - 2 No, revolving chair- 2No, Office chair-3 No, Godrej almirah - 1No) 458 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories. 459 Installation, Commissioning and testing of all above equipments for MCS with all power cables 460 TRAIL & RUN FOR 3 MONTHS WITHOUT ELECTRICITY CHARGES
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
43.
Power #9499937 Technical Bid
Tender For Selection Of Managed Service Provider And Cloud Services For Uppcl - BOM-A (Compute Infrastructure (IaaS)) 2 Item Code:A.1Virtual Machine with below configuration:a. CPU launch year 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Windows 2016 and above(2vCPU, RAM:16GB) 3 Item Code:A.2Virtual Machine with below configuration:a. CPU launch year 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Windows 2016 and above(4vCPU, RAM:32GB) 4 Item Code:A.3Virtual Machine with below configuration:a. CPU launch year 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Windows 2016 and above(8vCPU, RAM:64GB) 5 Item Code:A.4Virtual Machine with below configuration:a. CPU launch year 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Windows 2016 and above(16vCPU, RAM:128GB) 6 Item Code:A.5Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Linux (Opensource) (vCPU:2, RAM: 16GB ) 7 Item Code:A.6Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Linux (Opensource)(vCPU:4, RAM: 16GB ) 8 Item Code:A.7Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Linux (Opensource) (vCPU:4, RAM: 32GB ) 9 Item Code:A.8Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Linux (Opensource)(vCPU:8, RAM: 32GB ) 10 Item Code:A.9Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Linux (Opensource)(vCPU:8, RAM: 64GB ) 11 Item Code:A.10Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Linux (Opensource)(vCPU:16, RAM: 128GB ) 12 Item Code:A.11Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Linux (Opensource)(vCPU:32, RAM: 128GB) 13 Item Code:A.12Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Windows 2016 and abovee. MSSQL Database Standard(vCPU:2, RAM: 16GB) 14 Item Code:A.13Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Windows 2016 and abovee. MSSQL Database Standard(vCPU:4, RAM: 32GB) 15 Item Code:A.14Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- Windows 2016 and abovee. MSSQL Database Standard(vCPU:8, RAM: 64GB) 16 Item Code:A.15Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- RHEL 7.x/8.x /9.x(vCPU:2, RAM: 16GB ) 17 Item Code:A.16Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- RHEL 7.x/8.x /9.x(vCPU:4, RAM: 32GB ) 18 Item Code:A.17Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- RHEL 7.x/8.x /9.x(vCPU:8, RAM: 64GB ) 19 Item Code:A.18Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- RHEL 7.x/8.x /9.x(vCPU:16, RAM: 128GB ) 20 Item Code:A.19Virtual Machine with below configuration:a. CPU launch year- 2021 or laterb. CPU architecture- x86c. Physical to vCPU ratio- 1:2d. OS- RHEL 7.x/8.x /9.x(vCPU:32, RAM: 256GB ) 21 Item Code:A.20Virtual machine with below configuration: a. A10/A10G/L4 GPU b. CPU launch year- 2021 or later c. 8 vCPU d. 32 GB RAM e. OS: Linux (opensource) 22 BOM-B (MANAGED STORAGE SERVICE) 23 Item Code:B.1Managed Persistent Block storagea. Backed with SSDb. Minimum 3000 IOPS per TBc. Throughput 125 Mbps per TB 24 Item Code:B.2Managed Persistent Block storagea. Backed with SSDb. Minimum 6000 IOPS per TBc. Throughput 250 Mbps per TB 25 Item Code:B.3Managed Non-ephemeral & Hot HDD Block storage 26 Item Code:B.4Managed Object Storage (Frequent Access):a. Zone redundant storage in India.b. Storage durability of 99.999999999% 27 Item Code:B.5Managed Object Storage (Archival):a. Zone redundant storage in Indiab. Storage durability of 99.999999999% 28 Item Code:B.6Managed Shared File Storage:a. Backed with SSDb. Minimum 10000 IOPS per volumec. Throughput 250 Mbps per volumed. Storage durability of 99.999999999%e. Redundancy in the same site with three redundant copies 29 BOM-C (MANAGED NETWORK & SECURITY SERVICES) 30 Item Code:C.1Managed Application Gateway/Load Balancer (L7 layer) 31 Item Code:C.2.1Managed Native Network Firewall (Fixed Cost) 32 Item Code:C.2.2Managed Native Network Firewall (Variable Per TB processed data cost) 33 Item Code:C.3Secure Site-to-Site (S2S) IPSec VPN Connectivity 34 Item Code:C.4Data Egress 35 Item Code:C.5Data Ingress 36 Item Code:C.6Dedicated WAN Network Port to connect UPPCLs Data Centers to CSP Data Center 37 Item Code:C.7TSP Managed Router Hosting and operational Charges in CSP MUX Room including onetime cross connect 38 Item Code:C.8Managed NAT gateway 39 Item Code:C.9Managed VPN services 40 Item Code:C.10Managed Backup Solution 41 Item Code:C.11Static Public IP 42 BOM-D (MANAGED Mongo-DB ATLAS SERVICES) 43 Item Code:D.1Managed MongoDB-Atlas (M30) 44 Item Code:D.2Managed MongoDB-Atlas (M40) 45 Item Code:D.3Managed MongoDB-Atlas (M50) 46 Item Code:D.4Managed MongoDB-Atlas (M60) 47 Item Code:D.5Managed MongoDB-Atlas (M80) 48 BOM-E (Third-party CSP/OEM Service) 49 Item Code:E.1Docker Teams License 50 Item Code:E.2Google Maps (Dynamic) 51 Item Code:E.3Google Places API (New Autocomplete Requests) 52 Item Code:E.4Google Places API (Places Details-Basic) 53 Item Code:E.5Google Re-Captcha (V2 Enterprise) 54 MSP Operation & Support Charges 55 One-time charge for Application & DataMigration 56 AWARD COST ( L1 EVALUATION)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
44.
Drinking Water Supply and Sanitation #9470721 Technical Bid
tender for Budhanpur Nagar Panchayat Water Suplly Scheme District Azamgarh- Survey, Soil investigation, Design, Supply of all materials, labour, T&P etc. for Construction, Erection, Completion, Testing & Commissioning of Water Supply Works such as Over Head Tank, Tube well, Rising Main, Distribution System, Pump House, Boundary wall, Gate, Site Development, Renovation of existing facilities, including PLC SCADA Automation and other appurtenant works of water supply as specified in tender document ofBudhanpur Nagar Panchayat Water Supply Scheme, District- Azamgarhon Turnkey Basis. The Scope of work also includes trial & run of 3 months and Defect Liability period of 12 months for Civil Works & 24 months for E&M works after completion of successful Trial run. All completed and commissioned works of above scheme shall be handed over to concerned ULB. Sl. No. Item Description 1 Budhanpur Nagar Panchayat Water Supply Scheme(CIVIL WORKS ) 2 BOUNDARY WALL, GATE, APPROACH ROAD 3 Construction of 1.3 m high and 115 mm thick boundary wall with 230 mmx230 mm thick pillar made in Brick masonry in 1 cement and 4 sand mortar, the spacing between two pillar should not be more than 3.0 m c/c and the depth of foundation should not be less than 0.60m, with 0.5 m barbed wire fencing at the site of water works as per departmental type design and drawing, and, as per specifications given in the bid document including supply of all materials, labour T&P etc.for proper completion of work as per instructions of Engineer -in -charge. 4 Supply and fixing of 3.6 m x 1.20 m MS gateincluding fabrication and supply of steel and construction of bounary wall pillars of size 1.35mx0.30mx0.30m with ornamental brick work 115mm th. around RCC, as per departmental type design and drawingand as per specifications laid down in the bid document, including supply of all material, labour,T&P etc.required for proper completion of work as per instructions of Engineer-in-charge. 5 Supply and fixing of 1.2m wide MS wicket gate including fabrication and supply of steel and construction of boundary wall pillars etc. as per specifications laid down in the bid document, including supply of all material, labour,T&P etc.required for proper completion of work as per instructions of Engineer-in-charge. 6 Construction of B.O.E. Road for approach to water works, as per departmental type design and drawing and as per specifications laid down in the bid document, including supply of all materials , labour, T&P etc.required for proper completion of work as per instructions of Engineer -in -charge. 7 Earth filling work for proper leveling of water work site, in accordance with the contour map and Grid map of existing site enclosed including leveling, dressing, excavation and filling of earth where necessary and also including all labour, materials, T&P etc.required for proper completion of works and also including carriage of earth from within a distance of about 8 km. from the site of works as per instructions of Engineer -in -charge. 8 Provide all materials, labour, T&P etc. complete for construct of Drain as per the specifications for civil work given in the bid document, including supply of all material, labour and T&P etc complete and horiculture for site devlopment of water works as per instructions of Engineer -in -charge. 9 PUMP HOUSE 10 Provide all materials, labour, T&P etc. complete and construct Pump house size (3.00 x 3.60) m Chlorinating room size (1.8 x 2.5)m with bye pass chamber(1.00x1.00x1.15)m as per departmental type design and drawing (drawing no-D-2) and as per the specifications for civil work given in the bid document, including supply of all material, labour and T&P etc complete as per instructions of Engineer -in -charge. 11 OVERHEAD TANK (FOR ZONE -1) 12 Supply of all materials labour T&P etc. for complete construction of R.C.C. Over Head Tank of 700 KL capacity with 20 Meter staging above ground level with main components, including cost of soil testing and assuming bearing capacity of soil as 8 MT, with supply of design and drawings.All the water retaining components of OHT shall be casted in M-30 concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement, coarse sand and stone grit as per I.S. 11682 and I.S.456Seismiceffects and wind load should be taken into consideration as per I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure and including 1M wide RCC staircase, 1 m wide R.C.C. M30 balcony, M.S. ladder made of 50x50x6 mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium class G.I. pipes, One aluminum ladder inside the tank from top dome to bottom dome, R.C.C. railing with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m, Proper ventilator at top dome in circular shape of 1.2 m dia, Water level indicator fabricated with sensor connecting to automation, Lightening conductor as per I.S.S.2309 or its latest amendments of latest electricity rules, consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966, C.I. manhole of min 60x60cm size with locking arrangement, Supply, fixing, jointing of C.I.D/F Pipes of appropriate size with C.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest / relevant I.S. specificationswith all jointing materials for proper completion of work,Testing Bearing Capacity of soil,Supply and Fixing of appropriate size Electrically operated D/F Sluice Valve / Butter Fly Valves as per ISS 700/1969 or its latest amendments class “A” working pressure 10 Kg/cm2, Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit , Construction of washout / overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawing, Supply of 200 mm dia PVC pipe as per I.S.-4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water works compound, Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. 13 Inlet pipe 150 mm dia =29m (staging : 20 and below G.L. floor and apron : 5 and inside the tank :4)(Pump 2) 14 Provision for Bulk Water Meter 15 Super Dry Dial, Woltman Type, Removable Mechanism Water Flow Meter FLANGED Ends.Magnetic Drive.Vacuum Sealed Totaliser / Register.Encapsulated in Polymer Housing , having 5mm Thick toughened glass for clear visibility,having reading in m³, body / casing made from cast iron with high quality fusion bonded powder coating inside and outside the meter body for Max. corrosion protection,Temp. suitability max. upto 45⁰C and Conforming to ISO: 4064 Class ‘B’ accuracy 16 100 mm 17 Radar type Level transmitter 18 OVERHEAD TANK (FOR ZONE -2) 19 Supply of all materials labour T&P etc. for complete construction of R.C.C. Over Head Tank of 450 KL capacity with 18 Meter staging above ground level with main components, including cost of soil testing and assuming bearing capacity of soil as 8 MT, with supply of design and drawings.All the water retaining components of OHT shall be casted in M-30 concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement, coarse sand and stone grit as per I.S. 11682 and I.S.456Seismiceffects and wind load should be taken into consideration as per I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure and including 1M wide RCC staircase, 1 m wide R.C.C. M30 balcony, M.S. ladder made of 50x50x6 mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium class G.I. pipes, One aluminum ladder inside the tank from top dome to bottom dome, R.C.C. railing with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m, Proper ventilator at top dome in circular shape of 1.2 m dia, Water level indicator fabricated with sensor connecting to automation, Lightening conductor as per I.S.S.2309 or its latest amendments of latest electricity rules, consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966, C.I. manhole of min 60x60cm size with locking arrangement, Supply, fixing, jointing of C.I.D/F Pipes of appropriate size with C.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest / relevant I.S. specificationswith all jointing materials for proper completion of work, Testing Bearing Capacity of soil, Supply and Fixing of appropriate size Electrically operated D/F Sluice Valve / Butter Fly Valves as per ISS 700/1969 or its latest amendments class “A” working pressure 10 Kg/cm2, Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit , Construction of washout / overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawing, Supply of 200 mm dia PVC pipe as per I.S.-4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water works compound, Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. 20 Valves & Fittings 21 Inlet pipe 125 mm dia =27m (staging : 18 and below G.L. floor and apron : 5 and inside the tank :4)(Pump 2&3) 22 Provision for Bulk Water Meter 23 Super Dry Dial, Woltman Type, Removable Mechanism Water Flow Meter FLANGED Ends.Magnetic Drive.Vacuum Sealed Totaliser / Register.Encapsulated in Polymer Housing , having 5mm Thick toughened glass for clear visibility,having reading in m³, body / casing made from cast iron with high quality fusion bonded powder coating inside and outside the meter body for Max. corrosion protection,Temp. suitability max. upto 45⁰C and Conforming to ISO: 4064 Class ‘B’ accuracy 24 100 mm 25 Radar type Level transmitter 26 OVERHEAD TANK (FOR ZONE -3) 27 Supply of all materials labour T&P etc. for complete construction of R.C.C. Over Head Tank of 1100 KL capacity with 22 Meter staging above ground level with main components, including cost of soil testing and assuming bearing capacity of soil as 8 MT, with supply of design and drawings.All the water retaining components of OHT shall be casted in M-30 concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement, coarse sand and stone grit as per I.S. 11682 and I.S.456Construction of New Master ControlRoom (10 m x 5.156 m) for Scada system/ Admin Building/ Lab as per norms includingElectrification works , Sanitation and water supply. Seismiceffects and wind load should be taken into consideration as per I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure and including 1M wide RCC staircase, 1 m wide R.C.C. M30 balcony, M.S. ladder made of 50x50x6 mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium class G.I. pipes, One aluminum ladder inside the tank from top dome to bottom dome, R.C.C. railing with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m, Proper ventilator at top dome in circular shape of 1.2 m dia, Water level indicator fabricated with sensor connecting to automation, Lightening conductor as per I.S.S.2309 or its latest amendments of latest electricity rules, consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966, C.I. manhole of min 60x60cm size with locking arrangement, Supply, fixing, jointing of C.I.D/F Pipes of appropriate size with C.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest / relevant I.S. specificationswith all jointing materials for proper completion of work,Testing Bearing Capacity of soil,Supply and Fixing of appropriate size Electrically operated D/F Sluice Valve / Butter Fly Valves as per ISS 700/1969 or its latest amendments class “A” working pressure 10 Kg/cm2, Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit , Construction of washout / overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawing, Supply of 200 mm dia PVC pipe as per I.S.-4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water works compound, Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. 28 Valves & Fittings 29 Inlet pipe 150 mm dia =32m (staging : 22 and below G.L. floor and apron : 5 and inside the tank :4)(Pump 2&3) 30 Provision for Bulk Water Meter 31 Super Dry Dial, Woltman Type, Removable Mechanism Water Flow Meter FLANGED Ends.Magnetic Drive.Vacuum Sealed Totaliser / Register.Encapsulated in Polymer Housing , having 5mm Thick toughened glass for clear visibility,having reading in m³, body / casing made from cast iron with high quality fusion bonded powder coating inside and outside the meter body for Max. corrosion protection,Temp. suitability max. upto 45⁰C and Conforming to ISO: 4064 Class ‘B’ accuracy 32 100 mm 33 Radar type Level transmitter 34 REPARING OF OVERHEAD TANK (ZONE-4) 35 Removing with Concrete,Hached,roughened an clean throughly of OHT column including labour T&P etc complete. 36 R.C.C. with1:1.5:3 Cement, coarse sand Stone grit in Beam Slab Column 37 Supply and apply for coatingof apoxy resins as per specified relevant standard on the inner wall of water retaining storage tank. 38 Jacketing of Cement Concrete 1:1.5:3 Cement, coarse sand Stone grit Thickness 60mm Around old column in OHT including labour, T&P, etc complete 39 Repairing of railing of stair and balcony with 20mm GI Pipe including changing of old pipe and reflexing new pipe with labour and T&P complete. 40 Repairing of OHT for Scafolding (Shuttering, centring & shoring etc) for repairing of OHT for scafolding (Shuttering, centring & shoring etc) with all material, labour T&P complete. 41 Dismantling of OHT flooring with all labour T&P complete. 42 Painting two coats of approved paint Apex Ultima of varnish including supply of all materials, labour and T&P etc required for proper completion of the work in OHT. 43 Inlet pipe 100 mm dia =25m (staging : 16 and below G.L. floor and apron : 5 and inside the tank :4)(Pump 2) 44 Provision for Bulk Water Meter 45 Super Dry Dial, Woltman Type, Removable Mechanism Water Flow Meter FLANGED Ends.Magnetic Drive.Vacuum Sealed Totaliser / Register.Encapsulated in Polymer Housing , having 5mm Thick toughened glass for clear visibility,having reading in m³, body / casing made from cast iron with high quality fusion bonded powder coating inside and outside the meter body for Max. corrosion protection,Temp. suitability max. upto 45⁰C and Conforming to ISO: 4064 Class ‘B’ accuracy 46 100 mm 47 Radar type Level transmitter 48 RISING MAIN 49 Supply of following Sizes of D.I. pipes class K-9 with all jointing materials as per I.S. 8329/2000 or its latest amendments including F.O.R. destination and all taxes and insurance etc. complete. 50 150 mm dia class K-9 51 125 mm dia class K-9 52 100 mm dia class K-9 53 Supply of following sizes C.I. Sluice Valves/Scour Valves with Cap/Air Valve capable of with standing working pressure of 10 Kg/cm2 including F.O.R. destination and all taxes and insurance etc. complete. 54 150 mm dia 55 Excavation of earth for pipeline work with lift upto 1.5 and lead upto 50M filling back the earth into trenches including watering and ramming and disposal of surplus material with in 50M lead etc. complete. 56 Excavation in Ordinary Soil 57 Supply of all materials and construct following type valve chambers complete as per typedesign. 58 Masonary Type Chamber 59 Cartage from store to site of work following D.I. Pipe with specials, lowering the same into trenches and laying true to alignment and gradient, including jointing properly, testing of pipe line (but excluding the cost of trenching and cutting of pipes for making the length) etc. complete. 60 150 mm dia 61 125 mm dia 62 100 mm dia 63 Carting of following sizes CI/DF Sluice Valve/C.I. Air Valve and specials from departmental store to site of work and lowering them into the trenches, fixing in position and jointing them with pipeline and testing etc. complete. 64 Sluice valve 65 150 mm dia 66 Dismantling of following type road and stacking of useful material. 67 Bitumen Road 68 Reinstatement of following road charges to be paid to PWD/Loacal Body. 69 Bitumen Road 70 THRUST BLOCK 71 RCC with cement, coarse sand and 20mm gauge stone ballast in proportion of 1:1.5:3 for thrust block of pipeline excluding supply of reinforcement and its bending but including its fixing and binding wire in proportion, necessary centering and shuttering including curing and supply of all materials, labours T&P etc. required for proportion completion of work. 72 Mild steel or iron work in RCC work brought to required shape as necessary including bending for proper completion of work. 73 DISTRIBUTION SYSTEM 74 Supply of following sizes and type of pipes with all jointing materials such as socket, rubber gasket as per IS 4984/2016 and IS 8329/2000 or their latest amendment including F.O.R. destinationand all taxes and insurance etc. with loading, unloading and stacking all complete. 75 HDPE Pipe, PE-100 , PN-6 76 110 mm dia 77 140 mm dia 78 160 mm dia 79 DI K-7 Pipes 80 200 mm dia 81 250 mm dia 82 300 mm dia 83 350 mm dia 84 Carting of following size & type of pipes and specials from departmental store to site of work and lowering them into the trenches and laying true to alignmentand gradient and jointing with electro-fusion joints etc. complete (including testing of pipe lines and cutting of pipes for making up the length excluding the cost of trenches). 85 HDPE Pipe, PE-100 86 110 mm dia 87 140 mm dia 88 160 mm dia 89 DI K-7 Pipes 90 200 mm dia 91 250 mm dia 92 300 mm dia 93 350 mm dia 94 Excavation for ordinary soil and soil mixed with mooram, shingle, kankar for pipeline work in requireing the use of special T&P such as pickaxes, sabbals, etc. and lift up to 1.5 M and lead up to 50 M including filling back the excavated earth into the trenches with watering, ramming and disposal of surplus earth with in 50 M lead. 95 Excavation in Ordinary Soil 96 Supply of following sizes C.I.D./F Sluice valve including F.O.R. destination and taxes and insurance etc. complete as per relevant IS. 97 C. I. D/F Sluice Valve 98 100 mm dia 99 125 mm dia 100 200 mm dia 101 250 mm dia 102 300 mm dia 103 Scour Valve 80 mm dia 104 Fire Hydrant 80 mm dia 105 C.I. Single ball type Air Valve 50 mm dia 106 Carting of following sizes C.I.D./F Sluice Valve and specials from departmental store to site of work and lowering them into the trenches, fixing in position and jointingthem with pipelines and testing etc. complete (including supply of jointing materials). 107 C. I. D/F Sluice Valve 108 100 mm dia 109 125 mm dia 110 200 mm dia 111 250 mm dia 112 300 mm dia 113 Scour Valve 80 mm dia 114 (b) Fire Hydrant 80 mm dia 115 (c)C.I. Single ball type Air Valve 50 mm dia 116 Supply of all materials and construct following chambers as per type design with supply of all labour, T&P etc. complete. 117 (i)Masonary Type 118 (ii) Fire Hydrant Chamber 119 (iii) Air Valve Chamber 120 (iv) Surface Box Type 121 Dismentalling of following type road and stacking of useful material and temporary Reinstatement of road with old materials etc. complete. 122 BT Road 123 BOE Road 124 C.C. Road 125 IL Road 126 Reinstatement of following road charges to be paid to PWD/Local Body. 127 BT Road 128 BOE Road 129 C.C. Road 130 IL Road 131 Making House Connection with 20mm (OD) HPDE pipe with (63mm to 160mm) distribution main. 132 Provision for crossings of Drain/Culvert. Upto 300mm dia (width- 3.5 M) 133 Provision for crossings of Canal. (width- 5-10M) 134 STAFF QUARTER 135 Provide all materials labour, T&P etc. and construct single room staff quarter at water works site identified by the Engineer-in-charge as per department type design and drawing and specifications of civil works laid down in the bid document, including all material labour, T&P etc complete for proper completion of work as per instructions of Engineer -in -charge. (Drawing No.D-7) 136 GROUND WATER RECHARGING WELL 137 Constructinon of setting tank as per type design including filling of filter media etc proper completion of works 138 Constraction of 110 mm bore hole for 30 M depth and lowering PVC plain 18M and 110 mm PVC slatted 12M ,Total-30 M pipe 139 Constraction of Semi Circular Drain/Drainage works 140 Leveling and dressing of water works compound for proper slope for harvesting ofrainwater with filling of additional earth etc all complet. 141 E&M WORKS 142 Zone-1 143 TRANSPORTATION 144 RIG MACHINE 145 Transportation of rig machineincluding Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 146 AIR COMPRESSOR 147 Transportation of 350 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 148 O.P. UNIT 149 Transportation of 1 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 150 CONSTRUCTION OF TUBE WELL (DRILLING) As per IS 2800 (Part I & II) 151 Drilling of BORE 152 Logging of Bore 153 Drilling of 600mm dia bore from G.L. to 65m BGL. 154 Drilling of 450mm dia bore from 66m BGL to 100m BGL. 155 Drilling of 450mm dia bore from 101m BGL to 200m BGL. 156 LOWERING OF TUBE WELL ASSEMBLY AND SHROUDING OF T.W. BY GRAVEL- 157 Lowering of 300mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 180m BGL. 158 Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 60m BGL. 159 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 61m BGL to 100m BGL. 160 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 101m BGL to 180m BGL. 161 MATERIALS 162 TUBE WELL: ASSEMBLY (As per IS 4270, IS 8110) 163 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick ,M.S. ring ,100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 164 150mm dia MSERW 7.1mm thick plain /slotted pipe including withM.S ring 100X12mmthick , 1 noM.S. bail plug ,center guide etc comp in all respect. 165 PEA-GRAVEL (As per IS 4097) 166 1.60mm to 4.80mm size pea-gravel of Lalkuwan quarry duly screened, washed and proper stackingat site. 167 DEVELOPMENT OF TUBE WELL 168 Development of tube well by 350 PSI air compressor 169 Development of tube well by 350 PSI air compressor 170 Development of tube well by 1 cusec O.P. Unit 171 Development of tube well by 1 cusec O.P. Unit. 172 Welding of Tube well cover by Electric welding 173 TEST 174 Chemical and bacteriological test. 175 PUMP SET: 176 800 LPM, 55m head 1450rpm, 17.5H.P. submersible clear water pumping plant suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) 177 Switch gear with soft starter and cable 178 MAIN PIPING AND VALVES: 179 SITC of 100mm dia size main piping and valves with 36mtr column pipe, Automatic chlorination system (SCADA compatable), power wiring, earthing, painting, tool set, wiring of pump house, chain pulley block and gauges complete in all respect with all required material, T& P labour. 180 SITC of 25 KVA voltage stabilizer . 181 Spare pumping set including power cable, terminal kits complete in all respect. 182 Three Month Trial & Run Cost ZONE 1 183 Zone-2 184 TRANSPORTATION 185 RIG MACHINE 186 Transportation of rig machineincluding Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 187 AIR COMPRESSOR 188 Transportation of 350 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 189 O.P. UNIT 190 Transportation of 1 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 191 CONSTRUCTION OF TUBE WELL (DRILLING) As per IS 2800 (Part I & II) 192 Drilling of BORE 193 Logging of Bore 194 Drilling of 500mm dia bore from G.L. to 100m BGL. 195 Drilling of 500mm dia bore from 101m BGL to 200m BGL. 196 LOWERING OF TUBE WELL ASSEMBLY AND SHROUDING OF T.W. BY GRAVEL- 197 Lowering of 200mm X 200mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 180m BGL. 198 Lowering of 200mm dia MSERW 7.1mm thick plain pipe from GL to 100m BGL. 199 Lowering of200mm dia MSERW plain/slotted pipe 7.1mm thick from 101m BGL to 180m BGL. 200 MATERIALS 201 TUBE WELL: ASSEMBLY (As per IS 4270, IS 8110) 202 200mm dia size MSERW housing pipe 7.1mm thick , 1 noM.S. well cap 12mm thick ,M.S. ring ,100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 203 PEA-GRAVEL (As per IS 4097) 204 1.60mm to 4.80mm size pea-gravel of Lalkuwan quarry duly screened, washed and proper stackingat site. 205 DEVELOPMENT OF TUBE WELL 206 Development of tube well by 350 PSI air compressor 207 Development of tube well by 350 PSI air compressor 208 Development of tube well by 1 cusec O.P. Unit 209 Development of tube well by1 cusec O.P. Unit. 210 Welding of Tube well cover by Electric welding 211 TEST 212 Chemical and bacteriological test. 213 PUMP SET: 214 500LPM, 55m head 1450rpm, 12.5H.P. submersible clear water pumping plant suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989), Switch gear with soft starter and cable 215 MAIN PIPING AND VALVES: 216 SITC of 80mm dia size main piping and valves with 36mtr column pipe, Automatic chlorination system (SCADA compatable), power wiring, earthing, painting, tool set, wiring of pump house, chain pulley block and gauges complete in all respect with all required material, T& P labour. 217 SITC of 20 KVA voltage stabilizer . 218 Spare pumping set including power cable, terminal kits complete in all respect. 219 Three Month Trial & Run Cost ZONE2 220 Zone-3 221 TRANSPORTATION 222 RIG MACHINE 223 Transportation of rig machineincluding Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 224 AIR COMPRESSOR 225 Transportation of 350 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 226 O.P. UNIT 227 Transportation of 2 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 228 CONSTRUCTION OF TUBE WELL (DRILLING) As per IS 2800 (Part I & II) 229 Drilling of BORE 230 Logging of Bore 231 Drilling of 600mm dia bore from G.L. to 65m BGL. 232 Drilling of 450mm dia bore from 66m BGL to 100m BGL. 233 Drilling of 450mm dia bore from 101m BGL to 200m BGL. 234 LOWERING OF TUBE WELL ASSEMBLY AND SHROUDING OF T.W. BY GRAVEL- 235 Lowering of 300mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 180m BGL. 236 Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 60m BGL. 237 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 61m BGL to 100m BGL. 238 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 101m BGL to 180m BGL. 239 MATERIALS 240 TUBE WELL: ASSEMBLY (As per IS 4270, IS 8110) 241 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick ,M.S. ring ,100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 242 150mm dia MSERW 7.1mm thick plain /slotted pipe including withM.S ring 100X12mmthick , 1 noM.S. bail plug ,center guide etc comp in all respect. 243 PEA-GRAVEL (As per IS 4097) 244 1.60mm to 4.80mm size pea-gravel of Lalkuwan quarry duly screened, washed and proper stackingat site. 245 DEVELOPMENT OF TUBE WELL 246 Development of tube well by 350 PSI air compressor 247 Development of tube well by 350 PSI air compressor 248 Development of tube well by 2 cusec O.P. Unit 249 Development of tube well by 2 cusec O.P. Unit. 250 Welding of Tube well cover by Electric welding 251 TEST 252 Chemical and bacteriological test. 253 PUMP SET: 254 900 LPM, 55m head 1450rpm, 20H.P. submersible clear water pumping plant suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989), Switch gear with soft starter and cable 255 MAIN PIPING AND VALVES: 256 SITC of 100mm dia size main piping and valves with 36mtr column pipe, Automatic chlorination system (SCADA compatable), power wiring, earthing, painting, tool set, wiring of pump house, chain pulley block and gauges complete in all respect with all required material, T& P labour. 257 SITC of 30 KVA voltage stabilizer . 258 Spare pumping set including power cable, terminal kits complete in all respect. 259 Three Month Trial & Run Cost ZONE 3 260 ZONE-4 261 Estimate for Maintenance of 1 No Existing TW 262 SITC of 350 LPM 50m head pumping plant, soft starter, 15 KVA voltage stabilizer Automatic chlorination system (SCADA compatable), power wiring, chain pully block and gauges complete in all respect with all required material, T&P and labor. 263 SCADA Zone-1 ,2,3 & 4 264 CE & UL approved manufacturer’s RTU/ PLC in IP 65 encloser suitable to communicate with GSM based modem unit with CPU and power supply with analog and digital parameter and features as specified, onefor each tubewellto store and transmit data on GSM backbone. RTU/PLC designed with logic to transfer data at multiple stations 265 G.S.M./G.P.R.S. based wireless communication with 4G Modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations, all accessories included with signal enhancer anteena made for pumping plant 266 CE / UL certified Intelligent smart energy meter 267 Motor OperatedActuator with Sluice Valve . 268 CE / UL certified Electromagneticflowmeter of including required dismantling joints. 269 Auto phase reversal unit with inbuilt time delay & enclosure conforming to IEC: 60947-1 & IEC:60947-b-1) . 270 CE / UL certified Hydrostatatic type sub soil water level transmitter for Tubewell. 271 CE / UL certified Pressure Transmitter 272 CE / UL certified Surge protector for control panel 273 CE / UL certified 7 HMI touchscreen suitable to communicate with PLC/RTU, for local display & control of process parameters 274 Complete Cabling for tubewell including all power & control cables of all equipment at pumphouse and OHT 275 Control panel with IP 54 protection, industrial grade fro all equipments (separate for control (24V) and power equipments. 276 Installation, commissioning & testing 277 Test and trial run for 3 Months period 278 CE / UL certified Radar type level transmitter for OHT with installation 279 Master Control Station (MCS) 280 CE & BIS approved manufacturers industrial grade LCD monitor with latest configuration as per specification of size 65 281 Desktop/PC with i7 processor for as per spec mentioned in technical bid documents. 282 CE/UL approved manufacturers 3 KVA UPS with batteries as spec. mentioned for STP and Computer as per requirement 283 Full development version of required TAGS SCADA Software with costomization of software for MCS as per required as per spec mentioned in technical bid documents. 284 CE & UL approved manufacturers control room PLC with CPU & power supply at MCS in IP65 enclosure as per spec. mentioned 285 CE/UL certified field gateway agent for transfering data from MCS to control room 286 GSM based wireless / broadband/Equipment communication system for PLC capable to transfer and gather data from remote sites to control stations, including all accessories complete 287 CE/UL approved manufacturers Firewall for network protection 288 Lightning surge protector for ethernet communication protection 289 CE/UL approved manufacturers industrial grade ethernet switch 290 Mobile App facility system architecture complete. 291 Supply and Installation 1.5 Ton AC ( make Voltas, O-General)with stabilizer and other required item for installation 292 Canon/HP 1018/equivalent Laser printer with chair and table. 293 Security Survelliance IP camera 294 Installation, testing and commissioning with required furniture,Air Conditioner etc 295 Test and trial run
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
45.
Drinking Water Supply and Sanitation #9470719 Technical Bid
Tender For Bharat Bhari Nagar Panchayat Water Supply Reorganisation Scheme Siddharthanagar, Construction of Over head tank, pump house, staff Quarter, Boundry wall, Distributation system of pipeline, Water Rechaging unit, Scada Room,New Tube Well andE&M Releated Work in Bharat Bhari Nagar Panchayat Re-orgnization Water Supply Scheme. Sl. No. Item Description 1 Pump House cum Chloronome (2.5mx3.0mx3.0m)cum (2.5mx1.3mx3.0m) and(3.6mx3.0mx3.0m)cum (1.2mx1.8mx3.0m) 2 Excavation in foundation in ordinary soil (loam, clay or sand) including lift up to 1.5m and lead up to 50m. Filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and disposal of surplus earth up to a distance of 50m. from the centre of the foundation trenches. 3 Concrete with 40 mm gauge stone ballast, local sand and cement in proportion(8:4:1) in foundations and floors including supply off all materials, labour T and P etc. required for proper completion of the work. 4 First class brick work in1:6 cement and coarse sand mortar in foundation and plinth with proper curing including supply of all materials labour, T& P etc. required for proper completion of the work. 5 First class brick work in1:4 cement and coarse sand mortar in foundation and plinth with proper curing including supply of all materials labour, T& P etc. required for proper completion of the work. 6 (i) For chamber into PH. 7 As in item 1.03 above but in superstructure includingnecessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1 brick. 8 As in item 1.04 above but in 1:4 superstructure includingnecessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1/2 brick wall.(Above verandha slab) 9 20 mm thick damp proof coursewith cement and approved course sand in 1:2 including 5% water proofing materials of in the proportion as specified for proper complition of the work and including curing and shuttering as necessary. 10 R.C.C work with cement, coarse sand and 20mm gauge approved stone ballast in proportion of 1:1.5:3 in lintels of doors and windows,slab&chhaja excluding supply of reinforcement and itsbending, but including its fixing and binding the same with 0.50mm thick binding wire(to be supplied by the contractor) and including centering and shuttering, supply of all materials, labour, T & P etc. required for proper completion of the work. 11 (i) SLAB 12 (ii) BEAM/LINTAL 13 (iii) CHHAJJA 14 Mild steel or iron work in plain work such as R.C.C. or R.B. work (when not included, in over all rates) ,wrought to required shape as necessary incluiding bending for proper completion of thework incluiding supply of steel and.wastage. 15 Cement concrete with 20 mm gauge approved stone ballast,coarse sand and cement in the propotion of 4:2:1 including supply of all materials labour, T & P etc. required for proper completion of the work. 16 (i)For fixing of r.s. joist/hold fast etc. 17 R.C.C. man holecover (0.85*0.85*0.10m.) 18 Supply &fixing of angle iron of size 40*40*5mm door chaukhat including fixing of holdfast &125 mm size heavey duty hinges etc. complete. 19 (i) Size 1.2 *2.10 and 0.9*2.10 or as per direction of engineer-in-charge. 20 Supply &fixing of angle iron of size 40*40*5mm window/ventilator chaukhat with grill including fixing of holdfast &100 mm size heavey duty hinges etc. complete. 21 (i) Size 1.2*1.50 , 0.90 * 1.50 and 0.30 * 0.30-06no. as per direction of engineer-in-charge. 22 Supply and fixing of 35 mm thick plywood doorshutter Excluding AL drop tower bolt,handle,silencer & stoper etc. complete.All the accessaries should be heavey duty & approved make & quality. 23 Supply and fix 35mm thick sheesham wood fully Panelledwindows shutters including supply and fixing of wooden cleats and stops and fixing adjustments of hinges bolts locks handles spring and other fittings 24 Providing and fixventilators (as square bar grill) over opening including supply of all materials, labour, T&P etc. required for proper completion of work as per direction of Engineer-in -charge. 25 12 mm thick plaster in 1:6 with cementand coarse sand mortar over brick work minimum thickness not to be less than 10 mm, including supply of all materials, labour, T. & P.etc.Required for proper completion of the work. 26 12 mm thick plaster in 1:6 with cementand coarse sand mortar over rough face of onebrick work minimum thickness not to be less than 10 mm, including supply of all materials, labour, T. & P.etc.Required for proper completion of the work. 27 20mmthick cement plaster in dado or skirting in (1:2) consisting of cement and coarse sand laid in panels finished with 3mm floating coat of neat cement or 1:5 cement and marble dust including supply of all materialslabour T & P etc required for proper completion of the work. 28 Sand filling in plinth including supply of necessary quantity of sand from A distance not exceeding 10 km. from the site of work and including watering, dressing, etc. Rate to include the cost of all materials, labour, T and P etcrequired for proper completion of the work. 29 25mm thick 1:2:4 plain cement concrete floor and appron with cement coarse sand and 20mm gauge stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio1:5 as specified over and including 75mm thick base concrete consisting of cement local sand and 1st class brick ballast 40mm gauge in the proportion of 1:4:8 and removing any overlapping or mortar at the joints of panels if any and giving them uniform finish including supply of all materials labourand T and P etc. required for proper completion of the work. 30 40 mm thick 1:2:4 plain cement concrete floor with cement coarse sand and 20mm gauge stone ballast laid in panels finished with 3 mm floating coat of neat cement or cement and marble dust in ratio1:5 as specified.(without base concrete.) 31 Painting or varnishing new iron work in small areas or new wood work with one coat priming and two coat of approved paint or varnish including supply of all materials, Labour and T & P etc required for proper completion of the work. 32 White washing three coat including supply of all materials labour and T and P etc. required for proper completion of the work. 33 Finishing wall with waterproof cement paint of approved make and quality over one priming coat on new work with two coats, to give an even shade. Including prepration of surface &supply of all matrials labour T&P etc. required for proper completion of the work. 34 Supply of Rolled steel joists complete. Size 225*100*100mmLength - 2.9m. 35 Supply of Rolled steel joists complete. Size 225*100*100mmLength - 3.4m. 36 Fixed in position item no 1.33 excluding cost of joists but including all labour in handling and hoisting etc. complete.Size 225*100*100mm & Length - 2.90m. 37 Fixed in position item no. 1.34excluding cost of joists but including all labour in handling and hoisting etc. complete.Size 225*100*100mm & Length - 3.4m. 38 Supply and fix 100 mm dia. A.C. down pipe complete with rose heads bands with eye hole and groutings etc fixed to walls with suitable clamps . 39 Supply & Fixing of oxidized stainless steelfitting for door& window (AL drop tower bolt,handle,silencer & stoper etc.). 40 Anti termit treatment in foundationincluding supply off all materials, labour T and P etc. required for proper completion of the work. 41 Repairing & painting of Existing Pump House of Size (3.00 x 3.60 ) cum Chlorinating roomof size ( 1.2 x 1.8 ) . all releated work completion as per direction of Engineer in chargeincludingall material, labour,T&P etc.required for proper completion of work . 42 BY PASS CHAMBER 43 Excavation in foundation in ordinary soil (loam, clay or sand) including lift up to 1.5m and lead up to 50m. Filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and disposal of surplus earth up to a distance of 50m. from the centre of the foundation trenches. 44 Concrete with 40 mm gauge stone ballast, local sand and cement in proportion(8:4:1) in foundations and floors including supply off all materials, labour T and P etc. required for proper completion of the work. 45 I First class brick work in1:6 cement and coarse sand mortar in super structure with proper curing including supply of all materials labour, T& P etc. required for proper completion of the work 46 25mm thick 1:2:4 plain cement concrete floorwith cement coarse sand and 20mm gauge stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio1:5 as specified over and including 75mm thick base concrete consisting of cement local sand and 1st class brick ballast 40mm gauge in the proportion of 1:4:8 and removing any overlapping or mortar at the joints of panels if any and giving them uniform finish including supply of all materials labourand T and P etc. required for proper completion of the work. 47 20mmthick cement plaster in dado or skirting in (1:2) consisting of cement and coarse sand laid in panels finished with 3mm floating coat of neat cement or 1:5 cement and marble dust including supply of all materialslabour T & P etc required for proper completion of the work. 48 12 mm thick plaster in 1:6 with cementandl ocal sand mortar over rough face of onebrick work minimum thickness not to be less than 10 mm, including supply of all materials, labour, T. & P.etc.Required for proper completion of the work. 49 Boundary wall approach road etc 50 Excavation in foundation in ordinary soil (loam, clay or sand) including lift up to 1.5m and lead up to 50m. Filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and disposal of surplus earth up to a distance of 50m. from the centre of the foundation trenches. 51 Concrete with 40 mm gauge stone ballast, local sand and cement in proportion(8:4:1) in foundations and floors including supply off all materials, labour T and P etc. required for proper completion of the work. 52 I First class brick work in1:6 cement and coarse sand mortar in foundation and plinth with proper curing including supply of all materials labour, T& P etc. required for proper completion of the work 53 20 mm thick damp proof coursewith cement and approved course sand in 1:2 including 5% water proofing materials of in the proportion as specified for proper complition of the work and including curing and shuttering as necessary. 54 As in item 4.03above but in 1:4 superstructure includingnecessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1/2 brick wall.(Above verandha slab) 55 12 mm thick plaster in 1:6 with cementand coarse sand mortar over brick work minimum thickness not to be less than 10 mm, including supply of all materials, labour, T. & P.etc.Required for proper completion of the work. 56 12 mm thick plaster in 1:6 with cementand coarse sand mortar over brick work minimum thickness not to be less than 10 mm, including supply of all materials, labour, T. & P.etc.Required for proper completion of the work for pillar face.on rough surface. 57 Finishing wall with waterproof .Cement paint of approved make and quality over one priming coat on new work with two coats, to give an even shade. Including prepration of surface &supply of all matrials labour T&P etc. required for proper completion of the work. 58 Supply of fixing of 3.6 m wide gate including construction of pillars as per departmental type design including if all material, labour,T&P etc.required for proper completion of work 59 Construction of 80mm thick c.c. coloured interlockingpavers tiles with30mm thick fine sand bed over 100mm thick 1:6:12 C.C. basewith proper slope and camber including all material labour, T&P etc.required for proper completion of work. 60 Provision for aboroculture for all zone water works compound includingall material, labour,T&P etc.required for proper completion of work . 61 Repairing & painting of Existing Boundry wall in Zone-1 all releated work completion as per direction of Engineer in chargeincludingall material, labour,T&P etc.required for proper completion of work . 62 Provide all materials, labour, T and P etcrequired for proper completion of the work including leveling dressing exacavation of filling of earth where necessary for devolopment of water works sites including carriage of earth from distance of about 8 km. 63 Distrbution system,Rising main 64 Excavation for pipe line trenches including lift upto 1.50m and lead upto 50 m and refilling, watering, ramming of excavated earth in to trenches as per direction of engineer-in charge. 65 Supply,laying in true to alignment & gradient in trenches and testing of the following size and type of pipes with coupler,specials and all jointing materials such as solvent cement rubber rings etc.including F.O.R. destination, insurance and with loading, unloading and stacking etc. complete. 66 D.I.-K-9 (Rising Main) 67 dia- 80 MM 68 dia- 100 MM 69 dia- 150 MM 70 dia- 200 MM 71 D.I.-K-7 72 350mm 73 300mm 74 250mm 75 H.D.P.E PIPE 76 (i) 200mm 77 (ii) 160mm 78 (iii) 140mm 79 (iv) 110mm 80 (v) 90mm 81 Supply and fixing in position including supply of jointing materials such as nuts-boalt, rubber insertion white lead,valves and specials required etc. completeof the following size of C.I.D./F. Sluice valves, scour valves,20mm dia scewed down type air valve and fire hydrant containing80mm dia sluice valve and its accesories as per latest I.S. specification including F.O.R. destination, all taxes and insurance etc. complete for proper completion of work. 82 Sluice valve 83 350 mm dia 84 300 mm dia 85 250 mm dia 86 200 mm dia 87 150 mm dia 88 125 mm dia 89 100mm dia 90 80 mm dia 91 65 mm dia 92 Scour valve 93 80 mm dia 94 Air valve 95 20 mm dia 96 Firehydrant 97 Supply of all materials, labour,T&P etc.complete forconstruction of following chamber as per department type design. 98 Sluice valve chamber (masonary Type) 99 Sluice valve chamber (surface box Type) 100 Fire Hydrant 101 Air Valve Chamber 102 Scour Valve Chamber 103 Dismanting of Following type of surfaces including sorting out and stacking of serviceable materials and disposal of unserviceable materials upto a distance of 50 m. 104 (i) C.C.Road 105 (ii) Bituminous surface 106 (iii) B.O.E. Surface 107 (iv) Interlocking Surface 108 Provision for crossing of nalas, road, culvert and embankments (bundhs) etc. including shifting of telephone cables etc.along the alignement of pipe line including supply of C.I.Tyton pipes and specials,and their laying and jointing testing etc.complete . 109 i-Nala Crossing/culvert crossing 110 ii-Road Crossing through trenchless technique (80mm to 150mm) 111 iii-Road Crossing through trenchless technique (200mm to 350mm) 112 Reinstatement of above dismentalled road surface with old and new materials including supply of all materials, labour, T&P etc. required for proper completion of the work. 113 i-C.C.Road 114 ii-Bituminous surface 115 iii-B.O.E. Surface (Assuming 50% new brick and 50% old bricks used) 116 iv-Interlocking Surface (Assuming 50% new brick and 50% old bricks used) 117 Interconnection of new pipeline with existing pipeline including trenching,jointing,testing etc complete. 118 Making house connection with 20mm(OD) HDPE / AC/D.I. pipe main with Supply,Carting ,laying , jointing and fixing of the 15 mm (OD) G.I. pipe ,I.S.I. Mark Gunmetal Ferrul , I.S.I. Mark saddle/clamp of required size, C.I. bib kock of approved quality, J-Hook or M.S.U-clamp, 25cmX25cmX25cm C.C grouting of unsupported G.I. pipe all connection in inside thehouse and support on wall with suitable clampas perdirected by engineer-in chargeincluding cost of all jointing material, specials, labour, testing andT&P etc. complete. 119 R.C.C. with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in thrust blocks of pipe line excluding supply of reinforcement & its bending but including its fixing & binding the same with 0.50 mm thick binding wire in position & necessary centering & shuttering including curing and supply of all materials, labour, T & P etc. required for proper completion of the work. 120 Mild steel or iron work in R.C.C. wrought to required shape as necessary including bending for proper completion of the work including supply of steel & wastage etc. 121 OHT 122 Supply of all materials labour T&P etc. for complete construction of R.C.C. Over Head Tank following typeCapacity andstaging above ground level with main components, including cost of soil testing and assuming bearing capacity of soil as 8 MT, with supply of design and drawings.All the water retaining components of OHT shall be casted in M-30 concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement, coarse sand and stone grit as per I.S. 11682 and I.S.456.Seismiceffects and wind load should be taken into consideration as per I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure and including 1M wide RCC staircase, 1 m wide R.C.C. M25 balcony, M.S. ladder made of 50x50x6 mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium class G.I. pipes, One aluminum ladder inside the tank from top dome to bottom dome, railing with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case,bolcony and top dome, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m, Proper ventilator at top dome in circular shape of 1.2 m dia, Water level indicator fabricated with sensor connecting to automation, Lightening conductor as per I.S.S.2309 or its latest amendments of latest electricity rules, consisting of proper elevation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966, C.I. manhole of min 60x60cm size with locking arrangement, Supply, fixing, jointing of C.I.D/F Pipes of appropriate size with C.I.D/F specials conforming to IS 8329/2000 as vertical pipes for inlet, outlet, overflow and washout as per latest / relevant I.S. specificationswith all jointing materials for proper completion of work,Supply and Fixing of appropriate size manually operated D/F Sluice Valve / Butter Fly Valves as per ISS 700/1969 or its latest amendments class “A” working pressure 10 Kg/cm2, Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit , Construction of washout / overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawing, Supply of 200 mm dia PVC pipe as per I.S.-4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water works compound.Supplyand fixing of 1.8 m hight M.S. Gate in staire case at 2nd fligth as per direction of engineer -in-charge. Painting of all concrete surface and steel pipe works with water based exterior paint of approved make and quality as mentioned in tender documentover one priming coat on new work with two coats, to give an even shade and anticorrosive paints including prepration of surface &supply of all matrials labour T&P etc. required for proper completion of the work. AS PER DIRECTION OF EIC 123 (i)ZONE-5 -400KL Capacity 22 M staging 124 (i)ZONE-6 -550KL Capacity 22 M staging 125 (i)ZONE-7 -350KL Capacity 22 M staging 126 (i)ZONE-8 -300KL Capacity 20 M staging 127 (i)ZONE-9-600KL Capacity 22 M staging 128 Supply of 200mm dia P.V.C. Pipe as per letest /revlent I.S.specification including all taxes and insurance etc.F.O.R. destination for disposal of water from overflow and washout chamber to suitable point outside the water works compound including excavation of trenches.laying of pipe line etc.complete. 129 Repairing & painting of existing Over Head Tank of 100KL, 12 M stagingall releated work completion as per direction of Engineer in charge including supply of all material, labour, T&P etcproper completion of work . 130 Repairing & painting of existing Over Head Tank of 300KL, 16 M stagingall releated work completion as per direction of Engineer in charge including supply of all material, labour, T&P etcproper completion of work . 131 Repairing & painting of existing Over Head Tank of 250KL, 14 M stagingall releated work completion as per direction of Engineer in charge including supply of all material, labour, T&P etcproper completion of work . 132 Repairing & painting of existing Over Head Tank of 350KL, 18 M stagingall releated work completion as per direction of Engineer in charge including supply of all material, labour, T&P etcproper completion of work . 133 Repairing & painting of Existing Staff Quarterin zone-1 Water works campus including supply of all labour, material, T&P etc complete. 134 Construction of water recharging unit with water taping arrangement from roof and ground water recharging unitas perdirected by engineer-in charge including all material labour t&p etc. proper completion of work . 135 SCADA ROOM 136 Excavation in foundation in ordinarysoil (loam,clayorsand)includingliftupto1.50 m& lead up to 50 m,refilling,wateringandramming ofevcavatedearthintothetrenchesorspace betwwen the building and sides of foundation trenches or into the plinth and disposal of surplus earth up to the distance of 50 mfrom the center of the foundation trenches. 137 Concretewith40mmgaugestone ballast,local sand and cementin proportion in 8:4:1infoundation includingsupplyofall material,labourT &Petc.requiredforproper completion of work. 138 Ist. Class brick work in 1:6 cementand local mortar in foundation and plinth including supply of allmaterial,labourT&Petc.requiredforproper completion of work. 139 20 mm thick D.P.C.with cement and approved coarse sand 1:2 including 5% water proofing materialor inproportion as specied by themanufacturesincludingsupplyofall material,labourT &Petc.requiredforproper completion of work. 140 Ist. Class brickwork in 1:6 cementandlocalmortarinsuperstructure including supply of allmaterial,labourT&P etc.required for proper completion of work.Ist. 141 As in item 11.05 above but in 1:4 superstructure includingnecessary cutting and moulding of bricks as required and also including honey comb brick work thickness of wall not to be less than 1/2 brick wall. 142 Supply and fixing of M.S. angle iron chaukhatsof50mmx 50mm x 6mmwith M.S. sheet door shutter including simple moulding straightg work as in chaukhats and also supply of allmaterial,labourT&Petc.requiredforproper completion of work. 143 Fixingofholdfastofdoorsandwindows chaukhats already moulded on chaukhats inP.C.C.1:2:4etc.requiredinallrespectto complete the work. 144 R.C.C. work with cement,coarse sand and 20 mm gauge approved stone ballast in proportion of1:1.50:3insunshedandlintelondoorsand windows excluding supply of reinforcement and its bendingbutincludingitsfixingandbindingthe samewith0.50mmthick binding wire and the costofbinding wire and including necessary centeringandshutteringsupplyofall material,labour T&P etc. required for proper completion of work. 145 LINTAL/BEAM 146 SLAB/CHAJJA 147 Mild steel or iron work in plain work such as R.C.C. or R.B. work (when not included, in over all rates) ,wrought to required shape as necessary incluiding bending for proper completion of thework incluiding supply of steel and.wastage. 148 SupplyandfixingofZ-Sectionsection window framesandShuttersopenableoutsideas per drawinganddesignapprovedbyE/I,hingesof approvedquality,M.S.orC.I.handles,holdfast4 nos of M.S. flat25x5 mm and 150 mm long, pegs ofM.S.30cmlonghaving4holeswithpagester and brackets welded orriveted toframe completeincludingthecostofGlassPanes& includingsupply of all material,labour T&Petc. required for proper completion of work. 149 12 mm thick plaster in 1:6 with cementand coarse sand mortar over brick work minimum thickness not to be less than 10 mm, including supply of all materials, labour, T. & P.etc.Required for proper completion of the work. 150 Sameasitemno 11.15butin proportion1:4withcement andlocal sand mortar over ceiling. 151 25mm thick 1:2:4 plain cement concrete floor and appron with cement coarse sand and 20mm gauge stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio1:5 as specified over and including 75mm thick base concrete consisting of cement local sand and 1st class brick ballast 40mm gauge in the proportion of 1:4:8 and removing any overlapping or mortar at the joints of panels if any and giving them uniform finish including supply of all materials labourand T and P etc. required for proper completion of the work. 152 Same as item no 11.16 but in Apron. 153 Supply and fix 3 mm glass strips in position includingsupplyofallmaterial,labourT&Petc. required for proper completion of work. 154 Paintingorvarnishingnew workornewwoodworkinsmallareaswithone primingcoatandtwocoatofapprovedquality paint or varnish including supply of all material,labourT &Petc.requiredforproper completion of work. 155 Finishing wall with waterproof .Cement paint of approved make and quality over one priming coat on new work with two coats, to give an even shade. Including prepration of surface &supply of all matrials labour T&P etc. required for proper completion of the work. 156 115mmstringordripcoarseofIst.Class brick in 1:6 cement and local sand mortar including plastering, cutting drip notch as required andincludingsupplyofallmaterial,labourT&P etc. required for proper completion of work. 157 Sandfillinginplinthin including supply of all material,labour T & P etc.requiredfor proper completion of work. 158 Supplyandfixingoffanhooksboxtype includingsupply of all material,labour T&Petc. complete. 159 Provisionforinternalelectrificationincludingsupply of all material,labour,T&P etc. complete. 160 Provision for water supplyand sanitaryworks including supply of all material,labour,T&Petc. complete 161 E/M WORKS 162 ZONE-I 163 CONSTRUCTION OF TUBEWELL 164 Transportation of Rig m/c and its T&P including Erection and Dismantling of Rig m/c. 165 Transportation of 250 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 166 O.P.Unit 167 Transportation of 2/3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 168 Drilling of Bore 169 Logging of bore hole by departmental/approved electric logger. 170 Drilling of 500mm dia bore from G.L. to 60m BGL. 171 Drilling of 450mm dia bore from 61m BGL to 100m BGL. 172 Drilling of 450mm dia bore from 100m BGL to165m BGL. 173 TUBEWELL ASSEMBLY 174 200mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 175 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 08 no center guide etc comp in all respect. 176 LOWERING OF T/W ASSEMBLY 177 Lowering of 200mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 150m BGL. 178 Lowering of 200mm dia MSERW 7.1mm thick plain pipe from GL to 54m BGL. 179 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 55m BGL to 100m BGL. 180 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. 181 PEA-GRAVEL 182 Supply of 1.6 - 4.8 mm size Lal Kuwan Quarry Pea-Gravel Duly Washed,Screened and properly Stacked at Site. 183 DEVELOPMENT OF TUBE WELL 184 Development of tube well by 250 PSI air compressor 185 Development of tube well by 250 PSI air compressor 186 Development of tube well by 3 cusec O.P. Unit 187 Development of tube well by 3 cusec O.P. Unit. 188 TEST 189 Chemical and bacteriological test. 190 Pumping plant and Other instrumentation work 191 150 LPM, 40 m head 2900rpm,03 H.P. submersible clear water pumping plant suitable to operate on 415+ %5 volt, 50 Hz, 3 phase A.C. supply (as per IS 8034-1989) 192 SITC of Main piping & Valves (80 mm size) with 24 mtr. Column pipe, Electronic type Chlorinating plant Power wiring, earthing, Painting , Tools sets, wiring of pump house (internal & External) Chain Pulley block and gauges complete in all respect with allrequired material, T&P labour. 193 SITC of of 10 KVA Servo Voltage stabilizer or as per requirement (Input Voltage 230V±450V) to Output Voltage 415±1% As per IS 9815-1994. 194 Soft Stater with RS485Port- 400 V Class, 195 CE/UL Certified Intelligent Smart Energy Meter 196 Motor operated Actuator for without Sluice Valve of size upto 150 m 197 Electro magnetic flow meter upto150mm. 198 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 199 CE/UL Certified Pressure Transmiter . 200 Suitable capacity of booster pump with all accessories. Increase terminal Head upto 12 Meter. 201 SCADAAUTOMATION OF (NEW TUBEWELL and OLD Tubewell) 202 SCADAAUTOMATION ITEMS 203 CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modemunit with CPU & Power supply with analog & digital parameter & fetures as specified for each tubewell/OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified also enabled with UPS for power backup upto 2Hrs & automatic on/off switching arrangement. 204 G.S.M/G.P.R.S based wireless communication 4G Modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 205 CE/UL certified 7 HMI touch screen suitable to communicate with PLC/RTU for local display and control of process parameters. 206 CE/UL Certified Surge protector for control panel 207 Complete cabling for all equipments at pump house 208 Control panel with IP 54 protection, industrial grade for all equipment (Separate for control (24V) and power equipment). 209 Installation, commissioing & testing for one tubewell 210 Trial Run for 3 month period for one tubewell 211 Instrumentation Item for(OLD) Existing Tubewell 212 Motor operated Actuator for without Sluice Valve of size upto 150 m 213 Electro magnetic flow meter upto150mm. 214 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 215 CE/UL Certified Pressure Transmiter . 216 CE / UL certified Intelligent smart energy meter 217 Soft Stater with RS485Port- 400 V Class, 218 SITC of of 7.5 KVA Servo Voltage stabilizer or as per requirement (Input Voltage 230V±450V) to Output Voltage 415±1% As per IS 9815-1994. 219 Master control station (MCS) 220 SCADA DISPLAY 221 CE/UL & BIS Certified industrial gradeLED MONITOR with latest configuration as per specification. 222 (i) 65LED MONITOR With latest configuration 223 CE/UL/&BIS certified industrial grade large video screen(LVS)with latest configuration of LED type LFD ad per specificatio, MATRIX of 55 each panel. 224 (I)2x2 Matrix (4 panel) 225 Video wall media player of same OEM. 226 Desktop/PC with i5/i7 prosessor for as per spec mentioned in technical bid document. 227 CE/UL Cerfified 5 KVA UPS with batteries as per spec mentioned in technical bid document. 228 Full development version of reqrired TAGS SCADA Software with counstomization of software for MCS as per requirement as per spec mentioned in technical bid documents. 229 CE/UL certified master control room PLC with redundant CPU & power supply at MCS in IP54 enclouser as spec mentioned in technical bid documents. 230 EC/UL certified Field gateway agent for transfering data from MCS to Central control room. 231 GSM based wireless/Broadband/Equipment communication system for PLC capable to tranfer & received data & gather data from remote sited to control station, All accessoried included signal enhancer antenna along with running expences till DLP. 232 CE/UL Certified Firewall for network protection. 233 SURGE PROTECTOR FOR ETHERNET communication protection. 234 CE/UL certified industrial grade Ethernedt Switch 235 Mobile App Facility system architecture (industries internet baded & viewed through mobile apps for increased local & Remote Visibility). 236 Canon/HP or eqrivalent Laser Printe 1018 or equivement. 237 Security Surveillance IP camera with recorded (optional). 238 Installation, Commissioning & testing inclidung required funiture, A/c etc. 239 Trial run for 3 month period. 240 Automation of OHT 241 Motor operatedActuator without Sluce valve 160mm Size 242 Electromagnetic Flowmeter of 160mm Size 243 CE/UL Certified Radar type level transmittor for OHT 244 Three Month Trial & Run for 03 Month 245 ZONE-II 246 Transportation 247 Rig Machine 248 Transportation of Rig m/c and its T&P including Erection and Dismantling of Rig m/c. 249 Transportation of 250 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 250 O.P.Unit 251 Transportation of 2/3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 252 Drilling of Bore 253 Logging of bore hole by departmental/approved electric logger. 254 Drilling of 500mm dia bore from G.L. to 60m BGL. 255 Drilling of 450mm dia bore from 61m BGL to 100m BGL. 256 Drilling of 450mm dia bore from 100m BGL to165m BGL. 257 TUBEWELL ASSEMBLY 258 200mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 259 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 08 no center guide etc comp in all respect. 260 LOWERING OF T/W ASSEMBLY 261 Lowering of 200mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 150m BGL. 262 Lowering of 200mm dia MSERW 7.1mm thick plain pipe from GL to 54m BGL. 263 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 55m BGL to 100m BGL. 264 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. 265 PEA-GRAVEL 266 Supply of 1.6 - 4.8 mm size Lal Kuwan Quarry Pea-Gravel Duly Washed,Screened and properly Stacked at Site. 267 DEVELOPMENT OF TUBE WELL 268 Development of tube well by 250 PSI air compressor 269 Development of tube well by 250 PSI air compressor 270 Development of tube well by 3 cusec O.P. Unit 271 Development of tube well by 3 cusec O.P. Unit. 272 TEST 273 Chemical and bacteriological test. 274 Pumping plant and Other instrumentation work 275 SITC of 350 LPM, 44 m head 7.5 H.P. submersible pump set with 24 meter column pipe assembly, NRV, CI D/F Bend 90°, CI A/F Tee, D/F pipe (1.5m long 2 Nos and 1.0m long 1 No), Earthing, Painting Toolset, Power wiring of pump house internal and external, Chainpully block, and all Pumping plant accessories with nut bolts and rubber packing etc. Rates of items required for SCADA Automation of pumping plant are not included in these rates. 276 SITC of Automatic chlorination system SCADA Compatable chlorinating system. 277 Misc item such as protection ring, MCCB, Transformer oil, electric resistance, rubber sheet, 25 sqmm ormad cable and construction of canopyas per site requirement for protection of electronic device and safety purpose and nut bolts, rubber packing for extra/spare column pipe. 278 Supply & Erection of Servo Stabilizer of 15 KVA 279 Soft Stater with RS485Port- 400 V Class, 280 CE/UL Certified Intelligent Smart Energy Meter 281 Motor operated Actuator for with Sluice Valve of size upto 150 m 282 Electro magnetic flow meter upto150mm. 283 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 284 CE/UL Certified Pressure Transmiter . 285 SCADAAUTOMATION OF (NEW TUBEWELL and OLD Tubewell) 286 SCADAAUTOMATION ITEMS 287 CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modemunit with CPU & Power supply with analog & digital parameter & fetures as specified for each tubewell/OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified also enabled with UPS for power backup upto 2Hrs & automatic on/off switching arrangement. 288 G.S.M/G.P.R.S based wireless communication 4G Modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 289 CE/UL certified 7 HMI touch screen suitable to communicate with PLC/RTU for local display and control of process parameters. 290 CE/UL Certified Surge protector for control panel 291 Complete cabling for all equipments at pump house 292 Control panel with IP 54 protection, industrial grade for all equipment (Separate for control (24V) and power equipment). 293 Installation, commissioing & testing for one tubewell 294 Trial Run for 3 month period for one tubewell 295 Instrumentation Item for(OLD) Existing Tubewell 296 Motor operated Actuator for without Sluice Valve of size upto 150 m 297 Electro magnetic flow meter upto150mm. 298 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 299 CE/UL Certified Pressure Transmiter . 300 Soft Stater with RS485Port- 400 V Class, 301 SITC of of 15 KVA Servo Voltage stabilizer or as per requirement (Input Voltage 230V±450V) to Output Voltage 415±1% As per IS 9815-1994. 302 Automation of OHT 303 Motor operatedActuator without Sluce valve 200mm Size 304 Electromagnetic Flowmeter of 200mm Size 305 CE/UL Certified Radar type level transmittor for OHT 306 Three Month Trial & Run for 03 Month 307 ZONE-III 308 Transportation 309 Rig Machine 310 Transportation of Rig m/c and its T&P including Erection and Dismantling of Rig m/c. 311 Transportation of 250 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 312 O.P.Unit 313 Transportation of 2/3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 314 Drilling of Bore 315 Logging of bore hole by departmental/approved electric logger. 316 Drilling of 500mm dia bore from G.L. to 60m BGL. 317 Drilling of 450mm dia bore from 61m BGL to 100m BGL. 318 Drilling of 450mm dia bore from 100m BGL to165m BGL. 319 TUBEWELL ASSEMBLY 320 200mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 321 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 08 no center guide etc comp in all respect. 322 LOWERING OF T/W ASSEMBLY 323 Lowering of 200mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 150m BGL. 324 Lowering of 200mm dia MSERW 7.1mm thick plain pipe from GL to 54m BGL. 325 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 55m BGL to 100m BGL. 326 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. 327 PEA-GRAVEL 328 Supply of 1.6 - 4.8 mm size Lal Kuwan Quarry Pea-Gravel Duly Washed,Screened and properly Stacked at Site. 329 DEVELOPMENT OF TUBE WELL 330 Development of tube well by 250 PSI air compressor 331 Development of tube well by 250 PSI air compressor 332 Development of tube well by 3 cusec O.P. Unit 333 Development of tube well by 3 cusec O.P. Unit. 334 TEST 335 Chemical and bacteriological test. 336 Pumping plant and Other instrumentation work 337 SITC of 350 LPM, 42 m head 7.5 H.P. submersible pump set with 24 meter column pipe assembly, NRV, CI D/F Bend 90°, CI A/F Tee, D/F pipe (1.5m long 2 Nos and 1.0m long 1 No), Earthing, Painting Toolset, Power wiring of pump house internal and external, Chainpully block, and all Pumping plant accessories with nut bolts and rubber packing etc. Rates of items required for SCADA Automation of pumping plant are not included in these rates. 338 SITC of Automatic chlorination system SCADA Compatable chlorinating system. 339 Misc item such as protection ring, MCCB, Transformer oil, electric resistance, rubber sheet, 25 sqmm ormad cable and construction of canopyas per site requirement for protection of electronic device and safety purpose and nut bolts, rubber packing for extra/spare column pipe. 340 Supply & Erection of Servo Stabilizer of 15 KVA 341 Soft Stater with RS485Port- 400 V Class, 342 CE/UL Certified Intelligent Smart Energy Meter 343 Motor operated Actuator for with Sluice Valve of size upto 150 m 344 Electro magnetic flow meter upto150mm. 345 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 346 CE/UL Certified Pressure Transmiter . 347 Suitable capacity of booster pump with all accessories. Increase terminal Head upto 12 Meter. 348 SCADAAUTOMATION OF (NEW TUBEWELL and OLD Tubewell) 349 SCADAAUTOMATION ITEMS 350 CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modemunit with CPU & Power supply with analog & digital parameter & fetures as specified for each tubewell/OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified also enabled with UPS for power backup upto 2Hrs & automatic on/off switching arrangement. 351 G.S.M/G.P.R.S based wireless communication 4G Modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 352 CE/UL certified 7 HMI touch screen suitable to communicate with PLC/RTU for local display and control of process parameters. 353 CE/UL Certified Surge protector for control panel 354 Complete cabling for all equipments at pump house 355 Control panel with IP 54 protection, industrial grade for all equipment (Separate for control (24V) and power equipment). 356 Installation, commissioing & testing for one tubewell 357 Trial Run for 3 month period for one tubewell 358 Instrumentation Item for(OLD) Existing Tubewell 359 Motor operated Actuator for without Sluice Valve of size upto 150 m 360 Electro magnetic flow meter upto150mm. 361 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 362 CE/UL Certified Pressure Transmiter . 363 Soft Stater with RS485Port- 400 V Class, 364 SITC of of 15 KVA Servo Voltage stabilizer or as per requirement (Input Voltage 230V±450V) to Output Voltage 415±1% As per IS 9815-1994. 365 Automation of OHT 366 Motor operatedActuator without Sluce valve 200mm Size 367 Electromagnetic Flowmeter of 200mm Size 368 CE/UL Certified Radar type level transmittor for OHT 369 Three Month Trial & Run for 03 Month 370 ZONE-IV 371 Transportation 372 Rig Machine 373 Transportation of Rig m/c and its T&P including Erection and Dismantling of Rig m/c. 374 Transportation of 250 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 375 O.P.Unit 376 Transportation of 2/3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 377 Drilling of Bore 378 Logging of bore hole by departmental/approved electric logger. 379 Drilling of 500mm dia bore from G.L. to 60m BGL. 380 Drilling of 450mm dia bore from 61m BGL to 100m BGL. 381 Drilling of 450mm dia bore from 100m BGL to165m BGL. 382 TUBEWELL ASSEMBLY 383 200mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 384 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 08 no center guide etc comp in all respect. 385 LOWERING OF T/W ASSEMBLY 386 Lowering of 200mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 150m BGL. 387 Lowering of 200mm dia MSERW 7.1mm thick plain pipe from GL to 54m BGL. 388 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 55m BGL to 100m BGL. 389 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. 390 PEA-GRAVEL 391 Supply of 1.6 - 4.8 mm size Lal Kuwan Quarry Pea-Gravel Duly Washed,Screened and properly Stacked at Site. 392 DEVELOPMENT OF TUBE WELL 393 Development of tube well by 250 PSI air compressor 394 Development of tube well by 250 PSI air compressor 395 Development of tube well by 3 cusec O.P. Unit 396 Development of tube well by 3 cusec O.P. Unit. 397 TEST 398 Chemical and bacteriological test. 399 Pumping plant and Other instrumentation work 400 SITC of 400 LPM, 46 m head 10 H.P. submersible pump set with 24 meter column pipe assembly, NRV, CI D/F Bend 90°, CI A/F Tee, D/F pipe (1.5m long 2 Nos and 1.0m long 1 No), Earthing, Painting Toolset, Power wiring of pump house internal and external, Chainpully block, and all Pumping plant accessories with nut bolts and rubber packing etc. Rates of items required for SCADA Automation of pumping plant are not included in these rates. 401 SITC of Automatic chlorination system SCADA Compatable chlorinating system. 402 Misc item such as protection ring, MCCB, Transformer oil, electric resistance, rubber sheet, 25 sqmm ormad cable and construction of canopyas per site requirement for protection of electronic device and safety purpose and nut bolts, rubber packing for extra/spare column pipe. 403 Supply & Erection of Servo Stabilizer of 15 KVA 404 Soft Stater with RS485Port- 400 V Class, 405 CE/UL Certified Intelligent Smart Energy Meter 406 Motor operated Actuator for with Sluice Valve of size upto 150 m 407 Electro magnetic flow meter upto150mm. 408 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 409 CE/UL Certified Pressure Transmiter . 410 SCADAAUTOMATION OF (NEW TUBEWELL and OLD Tubewell) 411 SCADAAUTOMATION ITEMS 412 CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modemunit with CPU & Power supply with analog & digital parameter & fetures as specified for each tubewell/OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified also enabled with UPS for power backup upto 2Hrs & automatic on/off switching arrangement. 413 G.S.M/G.P.R.S based wireless communication 4G Modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 414 CE/UL certified 7 HMI touch screen suitable to communicate with PLC/RTU for local display and control of process parameters. 415 CE/UL Certified Surge protector for control panel 416 Complete cabling for all equipments at pump house 417 Control panel with IP 54 protection, industrial grade for all equipment (Separate for control (24V) and power equipment). 418 Installation, commissioing & testing for one tubewell 419 Trial Run for 3 month period for one tubewell 420 Instrumentation Item for(OLD) Existing Tubewell 421 Motor operated Actuator for without Sluice Valve of size upto 150 m 422 Electro magnetic flow meter upto150mm. 423 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 424 CE/UL Certified Pressure Transmiter . 425 Soft Stater with RS485Port- 400 V Class, 426 SITC of of 20 KVA Servo Voltage stabilizer or as per requirement (Input Voltage 230V±450V) to Output Voltage 415±1% As per IS 9815-1994. 427 Automation of OHT 428 Motor operatedActuator without Sluce valve 250mm Size 429 Electromagnetic Flowmeter of 250mm Size 430 CE/UL Certified Radar type level transmittor for OHT 431 Three Month Trial & Run for 03 Month 432 ZONE-V 433 Transportation 434 Rig Machine 435 Transportation of Rig m/c and its T&P including Erection and Dismantling of Rig m/c. 436 Transportation of 250 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 437 O.P.Unit 438 Transportation of 2/3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 439 Drilling of Bore 440 Logging of bore hole by departmental/approved electric logger. 441 Drilling of 500mm dia bore from G.L. to 60m BGL. 442 Drilling of 450mm dia bore from 61m BGL to 100m BGL. 443 Drilling of 450mm dia bore from 100m BGL to165m BGL. 444 TUBEWELL ASSEMBLY 445 200mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 446 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 08 no center guide etc comp in all respect. 447 LOWERING OF T/W ASSEMBLY 448 Lowering of 200mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 150m BGL. 449 Lowering of 200mm dia MSERW 7.1mm thick plain pipe from GL to 54m BGL. 450 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 55m BGL to 100m BGL. 451 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. 452 PEA-GRAVEL 453 Supply of 1.6 - 4.8 mm size Lal Kuwan Quarry Pea-Gravel Duly Washed,Screened and properly Stacked at Site. 454 DEVELOPMENT OF TUBE WELL 455 Development of tube well by 250 PSI air compressor 456 Development of tube well by 250 PSI air compressor 457 Development of tube well by 3 cusec O.P. Unit 458 Development of tube well by 3 cusec O.P. Unit. 459 TEST 460 Chemical and bacteriological test. 461 Pumping plant and Other instrumentation work 462 SITC of 450 LPM, 50 m head 10 H.P. submersible pump set with 24 meter column pipe assembly, NRV, CI D/F Bend 90°, CI A/F Tee, D/F pipe (1.5m long 2 Nos and 1.0m long 1 No), Earthing, Painting Toolset, Power wiring of pump house internal and external, Chainpully block, and all Pumping plant accessories with nut bolts and rubber packing etc. Rates of items required for SCADA Automation of pumping plant are not included in these rates. 463 SITC of Automatic chlorination system SCADA Compatable chlorinating system. 464 Misc item such as protection ring, MCCB, Transformer oil, electric resistance, rubber sheet, 25 sqmm ormad cable and construction of canopyas per site requirement for protection of electronic device and safety purpose and nut bolts, rubber packing for extra/spare column pipe. 465 Supply & Erection of Servo Stabilizer of 20 KVA 466 Soft Stater with RS485Port- 400 V Class, 467 CE/UL Certified Intelligent Smart Energy Meter 468 Motor operated Actuator for with Sluice Valve of size upto 150 m 469 Electro magnetic flow meter upto150mm. 470 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 471 CE/UL Certified Pressure Transmiter . 472 SCADAAUTOMATION OF NEW TUBEWELL 473 SCADAAUTOMATION ITEMS 474 CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modemunit with CPU & Power supply with analog & digital parameter & fetures as specified for each tubewell/OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified also enabled with UPS for power backup upto 2Hrs & automatic on/off switching arrangement. 475 G.S.M/G.P.R.S based wireless communication 4G Modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 476 CE/UL certified 7 HMI touch screen suitable to communicate with PLC/RTU for local display and control of process parameters. 477 CE/UL Certified Surge protector for control panel 478 Complete cabling for all equipments at pump house 479 Control panel with IP 54 protection, industrial grade for all equipment (Separate for control (24V) and power equipment). 480 Installation, commissioing & testing for one tubewell 481 Trial Run for 3 month period for one tubewell 482 Automation of OHT 483 Motor operatedActuator without Sluce valve 200mm Size 484 Electromagnetic Flowmeter of 200mm Size 485 CE/UL Certified Radar type level transmittor for OHT 486 Three Month Trial & Run for 03 Month 487 ZONE-VI 488 Transportation 489 Rig Machine 490 Transportation of Rig m/c and its T&P including Erection and Dismantling of Rig m/c. 491 Transportation of 250 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 492 O.P.Unit 493 Transportation of 2/3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 494 Drilling of Bore 495 Logging of bore hole by departmental/approved electric logger. 496 Drilling of 500mm dia bore from G.L. to 60m BGL. 497 Drilling of 450mm dia bore from 61m BGL to 100m BGL. 498 Drilling of 450mm dia bore from 100m BGL to165m BGL. 499 TUBEWELL ASSEMBLY 500 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 501 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 08 no center guide etc comp in all respect. 502 LOWERING OF T/W ASSEMBLY 503 Lowering of 300mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 150m BGL. 504 Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 54m BGL. 505 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 55m BGL to 100m BGL. 506 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. 507 PEA-GRAVEL 508 Supply of 1.6 - 4.8 mm size Lal Kuwan Quarry Pea-Gravel Duly Washed,Screened and properly Stacked at Site. 509 DEVELOPMENT OF TUBE WELL 510 Development of tube well by 250 PSI air compressor 511 Development of tube well by 250 PSI air compressor 512 Development of tube well by 3 cusec O.P. Unit 513 Development of tube well by 3 cusec O.P. Unit. 514 TEST 515 Chemical and bacteriological test. 516 Pumping plant and Other instrumentation work 517 SITC of 650 LPM, 50 m head 15 H.P. submersible pump set with 24 meter column pipe assembly, NRV, CI D/F Bend 90°, CI A/F Tee, D/F pipe (1.5m long 2 Nos and 1.0m long 1 No), Earthing, Painting Toolset, Power wiring of pump house internal and external, Chainpully block, and all Pumping plant accessories with nut bolts and rubber packing etc. Rates of items required for SCADA Automation of pumping plant are not included in these rates. 518 SITC of Automatic chlorination system SCADA Compatable chlorinating system. 519 Misc item such as protection ring, MCCB, Transformer oil, electric resistance, rubber sheet, 25 sqmm ormad cable and construction of canopyas per site requirement for protection of electronic device and safety purpose and nut bolts, rubber packing for extra/spare column pipe. 520 Supply & Erection of Servo Stabilizer of 25 KVA 521 CE/UL Certified Intelligent Smart Energy Meter 522 Soft Stater with RS485Port- 400 V Class, 523 Motor operated Actuator for without Sluice Valve of size upto 150 m 524 Electro magnetic flow meter upto150mm. 525 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 526 CE/UL Certified Pressure Transmiter . 527 SCADAAUTOMATION OF NEW TUBEWELL 528 SCADAAUTOMATION ITEMS 529 CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modemunit with CPU & Power supply with analog & digital parameter & fetures as specified for each tubewell/OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified also enabled with UPS for power backup upto 2Hrs & automatic on/off switching arrangement. 530 G.S.M/G.P.R.S based wireless communication 4G Modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 531 CE/UL certified 7 HMI touch screen suitable to communicate with PLC/RTU for local display and control of process parameters. 532 CE/UL Certified Surge protector for control panel 533 Complete cabling for all equipments at pump house 534 Control panel with IP 54 protection, industrial grade for all equipment (Separate for control (24V) and power equipment). 535 Installation, commissioing & testing for one tubewell 536 Trial Run for 3 month period for one tubewell 537 Automation of OHT 538 Motor operatedActuator without Sluce valve 250mm Size 539 Electromagnetic Flowmeter of 250mm Size 540 CE/UL Certified Radar type level transmittor for OHT 541 Three Month Trial & Run for 03 Month 542 ZONE-VII 543 Transportation 544 Rig Machine 545 Transportation of Rig m/c and its T&P including Erection and Dismantling of Rig m/c. 546 Transportation of 250 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 547 O.P.Unit 548 Transportation of 2/3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 549 Drilling of Bore 550 Logging of bore hole by departmental/approved electric logger. 551 Drilling of 500mm dia bore from G.L. to 60m BGL. 552 Drilling of 450mm dia bore from 61m BGL to 100m BGL. 553 Drilling of 450mm dia bore from 100m BGL to165m BGL. 554 TUBEWELL ASSEMBLY 555 200mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 556 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 08 no center guide etc comp in all respect. 557 LOWERING OF T/W ASSEMBLY 558 Lowering of 200mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 150m BGL. 559 Lowering of 200mm dia MSERW 7.1mm thick plain pipe from GL to 54m BGL. 560 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 55m BGL to 100m BGL. 561 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. 562 PEA-GRAVEL 563 Supply of 1.6 - 4.8 mm size Lal Kuwan Quarry Pea-Gravel Duly Washed,Screened and properly Stacked at Site. 564 DEVELOPMENT OF TUBE WELL 565 Development of tube well by 250 PSI air compressor 566 Development of tube well by 250 PSI air compressor 567 Development of tube well by 3 cusec O.P. Unit 568 Development of tube well by 3 cusec O.P. Unit. 569 TEST 570 Chemical and bacteriological test. 571 Pumping plant and Other instrumentation work 572 SITC of 400 LPM, 50 m head 10 H.P. submersible pump set with 24 meter column pipe assembly, NRV, CI D/F Bend 90°, CI A/F Tee, D/F pipe (1.5m long 2 Nos and 1.0m long 1 No), Earthing, Painting Toolset, Power wiring of pump house internal and external, Chainpully block, and all Pumping plant accessories with nut bolts and rubber packing etc. Rates of items required for SCADA Automation of pumping plant are not included in these rates. 573 SITC of Automatic chlorination system SCADA Compatable chlorinating system. 574 Misc item such as protection ring, MCCB, Transformer oil, electric resistance, rubber sheet, 25 sqmm ormad cable and construction of canopyas per site requirement for protection of electronic device and safety purpose and nut bolts, rubber packing for extra/spare column pipe. 575 Supply & Erection of Servo Stabilizer of 20 KVA 576 CE/UL Certified Intelligent Smart Energy Meter 577 Soft Stater with RS485Port- 400 V Class, 578 Motor operated Actuator for with Sluice Valve of size upto 150 m 579 Electro magnetic flow meter upto150mm. 580 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 581 CE/UL Certified Pressure Transmiter . 582 SCADAAUTOMATION OF NEW TUBEWELL 583 SCADAAUTOMATION ITEMS 584 CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modemunit with CPU & Power supply with analog & digital parameter & fetures as specified for each tubewell/OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified also enabled with UPS for power backup upto 2Hrs & automatic on/off switching arrangement. 585 G.S.M/G.P.R.S based wireless communication 4G Modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 586 CE/UL certified 7 HMI touch screen suitable to communicate with PLC/RTU for local display and control of process parameters. 587 CE/UL Certified Surge protector for control panel 588 Complete cabling for all equipments at pump house 589 Control panel with IP 54 protection, industrial grade for all equipment (Separate for control (24V) and power equipment). 590 Installation, commissioing & testing for one tubewell 591 Trial Run for 3 month period for one tubewell 592 Automation of OHT 593 Motor operatedActuator without Sluce valve 200mm Size 594 Electromagnetic Flowmeter of 200mm Size 595 CE/UL Certified Radar type level transmittor for OHT 596 Three Month Trial & Run for 03 Month 597 ZONE-VIII 598 Transportation 599 Rig Machine 600 Transportation of Rig m/c and its T&P including Erection and Dismantling of Rig m/c. 601 Transportation of 250 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 602 O.P.Unit 603 Transportation of 2/3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 604 Drilling of Bore 605 Logging of bore hole by departmental/approved electric logger. 606 Drilling of 500mm dia bore from G.L. to 60m BGL. 607 Drilling of 450mm dia bore from 61m BGL to 100m BGL. 608 Drilling of 450mm dia bore from 100m BGL to165m BGL. 609 TUBEWELL ASSEMBLY 610 200mm dia size MSERW housing pipe 7.1mm thick including with 1 no 200 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 611 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 08 no center guide etc comp in all respect. 612 LOWERING OF T/W ASSEMBLY 613 Lowering of 200mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 150m BGL. 614 Lowering of 200mm dia MSERW 7.1mm thick plain pipe from GL to 54m BGL. 615 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 55m BGL to 100m BGL. 616 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. 617 PEA-GRAVEL 618 Supply of 1.6 - 4.8 mm size Lal Kuwan Quarry Pea-Gravel Duly Washed,Screened and properly Stacked at Site. 619 DEVELOPMENT OF TUBE WELL 620 Development of tube well by 250 PSI air compressor 621 Development of tube well by 250 PSI air compressor 622 Development of tube well by 3 cusec O.P. Unit 623 Development of tube well by 3 cusec O.P. Unit. 624 TEST 625 Chemical and bacteriological test. 626 Pumping plant and Other instrumentation work 627 SITC of 350 LPM, 48 m head 10 H.P. submersible pump set with 24 meter column pipe assembly, NRV, CI D/F Bend 90°, CI A/F Tee, D/F pipe (1.5m long 2 Nos and 1.0m long 1 No), Earthing, Painting Toolset, Power wiring of pump house internal and external, Chainpully block, and all Pumping plant accessories with nut bolts and rubber packing etc. Rates of items required for SCADA Automation of pumping plant are not included in these rates. 628 SITC of Automatic chlorination system SCADA Compatable chlorinating system. 629 Misc item such as protection ring, MCCB, Transformer oil, electric resistance, rubber sheet, 25 sqmm ormad cable and construction of canopyas per site requirement for protection of electronic device and safety purpose and nut bolts, rubber packing for extra/spare column pipe. 630 Supply & Erection of Servo Stabilizer of 15 KVA 631 CE/UL Certified Intelligent Smart Energy Meter 632 Soft Stater with RS485Port- 400 V Class, 633 Motor operated Actuator for with Sluice Valve of size upto 150 m 634 Electro magnetic flow meter upto150mm. 635 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 636 CE/UL Certified Pressure Transmiter . 637 SCADAAUTOMATION OF NEW TUBEWELL 638 SCADAAUTOMATION ITEMS 639 CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modemunit with CPU & Power supply with analog & digital parameter & fetures as specified for each tubewell/OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified also enabled with UPS for power backup upto 2Hrs & automatic on/off switching arrangement. 640 G.S.M/G.P.R.S based wireless communication 4G Modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 641 CE/UL certified 7 HMI touch screen suitable to communicate with PLC/RTU for local display and control of process parameters. 642 CE/UL Certified Surge protector for control panel 643 Complete cabling for all equipments at pump house 644 Control panel with IP 54 protection, industrial grade for all equipment (Separate for control (24V) and power equipment). 645 Installation, commissioing & testing for one tubewell 646 Trial Run for 3 month period for one tubewell 647 Automation of OHT 648 Motor operatedActuator without Sluce valve 200mm Size 649 Electromagnetic Flowmeter of 200mm Size 650 CE/UL Certified Radar type level transmittor for OHT 651 Three Month Trial & Run for 03 Month 652 ZONE-IX 653 Transportation 654 Rig Machine 655 Transportation of Rig m/c and its T&P including Erection and Dismantling of Rig m/c. 656 Transportation of 250 psi compressor including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 657 O.P.Unit 658 Transportation of 2/3 cusec op unit including Loading , unloading, Erection, Dismantling & labour etc complete in all respect . 659 Drilling of Bore 660 Logging of bore hole by departmental/approved electric logger. 661 Drilling of 500mm dia bore from G.L. to 60m BGL. 662 Drilling of 450mm dia bore from 61m BGL to 100m BGL. 663 Drilling of 450mm dia bore from 100m BGL to165m BGL. 664 LOWERING OF T/W ASSEMBLY 665 Lowering of 300mm X 150mm dia tube well assembly in bore hole and shrouding of pea gravel between annular space ofbore hole and T.W. assembly from G.L. to 150m BGL. 666 Lowering of 300mm dia MSERW 7.1mm thick plain pipe from GL to 54m BGL. 667 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 55m BGL to 100m BGL. 668 Lowering of 150mm dia MSERW plain/slotted pipe 7.1mm thick from 100m BGL to 150m BGL. 669 TUBEWELL ASSEMBLY 670 300mm dia size MSERW housing pipe 7.1mm thick including with 1 no 300 X 150mm dia M.S reducer 16mm thick, 1 noM.S. well cap 12mm thick , 10 no M.S. ring 100X12mm thick, M.S. S/I clamp ,T.W. Support (I Section) etc comp in all respect . 671 150mm dia MSERW 7.1mm thick plain /slotted pipe including with 20 no M.S ring 100X12mmthick , 1 noM.S. bail plug , 08 no center guide etc comp in all respect. 672 PEA-GRAVEL 673 Supply of 1.6 - 4.8 mm size Lal Kuwan Quarry Pea-Gravel Duly Washed,Screened and properly Stacked at Site. 674 DEVELOPMENT OF TUBE WELL 675 Development of tube well by 250 PSI air compressor 676 Development of tube well by 250 PSI air compressor 677 Development of tube well by 3 cusec O.P. Unit 678 Development of tube well by 3 cusec O.P. Unit. 679 TEST 680 Chemical and bacteriological test. 681 Pumping plant and Other instrumentation work 682 SITC of 700 LPM, 50 m head 15 H.P. submersible pump set with 24 meter column pipe assembly, NRV, CI D/F Bend 90°, CI A/F Tee, D/F pipe (1.5m long 2 Nos and 1.0m long 1 No), Earthing, Painting Toolset, Power wiring of pump house internal and external, Chainpully block, and all Pumping plant accessories with nut bolts and rubber packing etc. Rates of items required for SCADA Automation of pumping plant are not included in these rates. 683 SITC of Automatic chlorination system SCADA Compatable chlorinating system. 684 Misc item such as protection ring, MCCB, Transformer oil, electric resistance, rubber sheet, 25 sqmm ormad cable and construction of canopyas per site requirement for protection of electronic device and safety purpose and nut bolts, rubber packing for extra/spare column pipe. 685 Supply & Erection of Servo Stabilizer of 25 KVA 686 CE/UL Certified Intelligent Smart Energy Meter 687 Soft Stater with RS485Port- 400 V Class, 688 Motor operated Actuator for without Sluice Valve of size upto 150 m 689 Electro magnetic flow meter upto150mm. 690 CE/UL Certified Hydrostatic type sub soil Water Level Transmiter for Tubewell 691 CE/UL Certified Pressure Transmiter . 692 SCADAAUTOMATION OF NEW TUBEWELL 693 SCADAAUTOMATION ITEMS 694 CE & UL Certified PLC/RTU in IP 54 enclosure suitable to Communicate with GSM based modemunit with CPU & Power supply with analog & digital parameter & fetures as specified for each tubewell/OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified also enabled with UPS for power backup upto 2Hrs & automatic on/off switching arrangement. 695 G.S.M/G.P.R.S based wireless communication 4G Modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification. 696 CE/UL certified 7 HMI touch screen suitable to communicate with PLC/RTU for local display and control of process parameters. 697 CE/UL Certified Surge protector for control panel 698 Complete cabling for all equipments at pump house 699 Control panel with IP 54 protection, industrial grade for all equipment (Separate for control (24V) and power equipment). 700 Installation, commissioing & testing for one tubewell 701 Trial Run for 3 month period for one tubewell 702 Automation of OHT 703 Motor operatedActuator without Sluce valve 200mm Size 704 Electromagnetic Flowmeter of 200mm Size 705 CE/UL Certified Radar type level transmittor for OHT 706 Three Month Trial & Run for 03 Month
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
46.
Drinking Water Supply and Sanitation #9460338 Technical Bid
Tender For Baragaon Nagar Panchayat Reorganization Water Supply Scheme Under Amrit 2.0; CIVIL WORK Pump House 2 Supply of all materials labour for Construction of Pumphouse (3.60 x 3.00 x 3.00 M) CUM Chloronating Room (2.80 x 1.50 x 3.00 M) Including all material labour t&p etc Complete as per design & drawing. As per type design of Jal Nigam as per direction of engineer incharge. 3 Supply of all materials labour for Construction of Additional Dozer Room at every zone for DMA (2..50 x 3.00 x 4.00 M) Including all material labour t&p etc Complete as per design & drawing. as per direction of engineer incharge 4 Supply of all materials labour for Construction ofMCS Room (8.00 x 5.00 x 4.00 M) Including all material labour t&p etc Complete as per design & drawing. as per direction of engineer incharge 5 RISING MAIN FOR ZONE 1 AND 2& BYE-PASS ARRANGEMENT 6 Supply of the following sizes of D.I. pipes Class K-9 conforming to latest I.S. 8329/2000 complete in all respect F.O.R. destination including all taxes and insurance including speials. 7 150 mm DI K-9 8 Supply of the following sizes of C.I. Double flanged sluice valves as per I.S. 780/1960 for testing 10kg/Sqcm F.O.R Destination including all taxes and Insurance. 9 150 mm. dia. 10 Excavation in ordinary soil (lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 10 KM from the center of the foundation trenches.as per direction of engineer incharge 11 Excavation for pipe line in all type of rock by chieselling /blastingincluding supply ofblasting materials and stacking properly useful materials with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within10 KM.as per direction of engineer incharge 12 Carting from the store (up to 8 Km.) The following sizes of D.I. double pipe K-9 and specials to the site of work lowering them in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolts, rubber insertion, white lead etc. com- plate but excluding cost of trenching and cutting of pipes etc. For making of lengths but including making joints. 13 150 mm. dia. 14 Carting of D/F Sluice valves of following sizes to the site of workslowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete excluding values and specials required but including the testing etc. complete. 15 150 mm. dia. 16 Supply of all materials, labour T&P etc. required and construct masonry type sluice valves chamber as per type design including supply and materials labour, T&P etc. complete. 17 Supply of all materials, labour, T & P etc. required and construct thrust blocks in RCC 1:2:4 at the bends and below the Valves. 18 Dismantling and reinstatement of following type of surface including sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. as per direction of engineer incharge 19 BITUMINOUS ROAD 20 C.C. ROAD 21 Renovation of O.H.T. :- Dismantiling of OHT Flooring , Removing weak concrete hacked, roughended and clean thoroughly of OHT Coloumn for strenthening of OHT Coloumn M S or Iron Work in Plain work Supply of Aporxy resin for Old surface to joint new surface of cement concrete.Jacketing of Cement Concrete 1:1:5:3 Coment Course Sand, Stone Grit Thickness 60 mm Around old coloumn in OHT Including labour T&P etc complete.Construction of RCC foundation of Coloumn Pedestal with 1:1:5:3 cement concrete Dismantling of inner portion old plaster including disposal of malba (vertical wall, cone wall, bottom dome and top dome ).Repairing of Railing of Stair and Balcony with 20mm GI Pipe including changing of old pipe and reflexing new pipe, 12 mm thick Plaster 1:3 Cement and Course sand andwater Proofing Coumpond Chemical over the tank intenal wall and bottom dome to remove the leakage and seepage of tank(vertical wall, cone wall, bottom dome and top dome ). Changing of old & Damaged manhole cover including its fixing Scafoldingfor repairing & Painting of OHT, Dismantling/ Fixing of Inlet, Outlet, Over Flow washout pipe of OHT ,Changing of inlet outlet and washout unserviceable DI Pipe including dismantiling of old pipeand fixing of new pipe 40mm thick PCC (1:2:4) flooring with cement coarse sand and 20mm gauge stone ballast laid in pannels finished with 3mm thick floating coat of neat cement over base concrete 75mm thick consisting of cement, local sand 40mm brick ballast in 1:4:8 including Painting two coats of approved paint Apex Ultima or varnish including supply of all materials, labour and T&P etc required for Proper completion of the work in OHT. as per direction of engineer incharge 22 Design & Supply of all materials, T&P etc required for construction of specified capacity OHT with specified stagingas per following requirements:- 23 Capacity-As Specified in Item No 1.1 to 1.12Grading of OHT- M--35 The food grade epoxy coating of FOSROC / CIEBA GAIKI or reputated brand on the all inside surface area of water container after treatment of water tightness.Stair case- Seperate two column basedRCC staircase and 1 m wide balcony with box type RCC structure at the entrance of the staircase to protect the entry of unwanted persons & locking arrangement with MS door.Railings- 20 mm dia G.I. Pipe (medium quality steel tubes as per IS 1239) railing consisting of 3 rows of with posts height (50x50x6 mm MS angle) (1.0 m) of same pipe around stair case (both sides), balcony & at the top dome periphery, including epoxy 3mm thick coating above base coat, 65mm dia GI pipe (medium quality steel tubes as per IS 1239) ladder with FRP coating from opening of top dome to inside the tank and top of bottom dome. Supply and fixing of CI man hole cover with locking device at opening on the top dome to go inside the tank. Ventilator and Water level indicator - RCC ventilator with SS grill (10 sqm at the spacing of 30 mm) with steel mosquito mesh,electronic digitalwater level indicator with ultrasonic sensor including supply & fixing of solar energy arrangements. Lightening conductor- A good quality lightening conductor covered with PVC casing Vertical pipes- Inlet Pipe - 150 mm, outlet pipe - 250 mm, overflow - 150 mm & washout pipe - 100 mmC.I. D/F pipe as per design criteria upto 1 m beyond the apron, IVC/Kirloskar sluice valve on inlet, out let & at wash out pipe, duck foot bend, puddle collers and bell mouths. 10 mm thick & 150 mm wide S S plate clamp for fixing of verticle pipes with RCC columns (minimum 2 clamps between ends of each pipe). It also includes bye pass arrangement of OHT. The velocity in the pipes shall not exceed 1.5 m/sFlooring, Apron & Drain- 100 mm thick PCC of 1:2:4 & 100 mm thick CC of 1:1:2 with 6 mm thick glass strips not more than 1 sqm area upto 2 m from outer edge of the columns of OHT, drain of size 200 mm x 200 mm with 150 mm thick CC of 1:1:2 including necessary sluice valve chambers and pipe line required for proper drainage of rain water from the campus.Sluice valve chambers- 3 nos. of sluice valve chamber (minimum size 1.5 x 1.5 x 1.5 m or larger size as per requirements of site) of brick work with 200 mm thick RCC slab..Sluice valve chambers- 3 nos. of sluice valve chamber (minimum size 1.5 x 1.5 x 1.5 m or larger size as per requirements of site) of brick work with 200 mm thick RCC slab.Two coat apex painting over one coat primer of approved colour of asian / berger paints after fixing of RCC surface with grinder, repair of minor holes, unevenness etc. proper completion of work.Soil bearing capacity- Structure shall be design on the basis of maximum bearing capacity of 8 tonne/sqm or minimum as per actual on the basis of test report of soil bearing capacity. as per direction of engineer incharge 24 Sub Zone of Proposed OHT 18 m Staging ( Including 1m made of Gl or as per site condition ) 25 Proposed OHT Zone-II 400 kl Capacity and 18 m Staging 26 Cost of Testing for bearing capacity of soil for various sites of proposed OHT 27 DISTRIBUTION SYSTEM 28 Supply of following sizes D.I. K-7 pipes,as per I.S.- 8329/2000 or its Latest ammenmendsuitable for pipe with rubber gasket, coupling, coupler, including supply of specials DI DF/DI DS like Tees, Vertical / Horizontal Bend, Gap Pieces required for case of sectional testing etc and making S/S joints all materials T&P etc. all complete. as per I.S. F.O.R. destination including all local cartage etc complete.. ( Rising main Purpose ) 29 250 mm dia D.I.K-7 30 200 mm dia D.I K-7 31 Supply of the following HDPE Pipes as per B.I.S. code no. 4984/2016 or its latest amendment including cost of 1 HDPE coupler per pipe length and all bend , reducer, tee and all type of spacial which are required in Electro fusion joint fitting inclusive of all taxes and duties, 3rd party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges etc. F.O.R. destination etc. complete 32 180 mm dia HDPE PN10/PE100 33 160 mm dia HDPE PN10/PE100 34 140 mm dia HDPE PN10/PE100 35 110 mm dia HDPE PN10/PE100 36 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 37 250 mm dia 38 200 mm dia 39 150 mm dia 40 100 mm dia 41 Supply of the following sizes of C.I. Double flanged scour valves as per I.S. 780 class-1 working pressure 10 kg/Sqcm F.O.R Destination including all taxes and insurance. 42 80 mm dia 43 Supply of 50 mm dia screwed down type air valve with gun metal seat at site stone including all taxes. 44 Supply of underground sluice valves type fire hydrant consisting of 80 mm dia tail pieces, 80 mm dia duck foot band and 63 mm dia standard make iron coupling with cap and chain etc. complete to IS.369/1995 at site including all taxes. 45 Excavation for pipe line work in ordinary soil(lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 10 KM from the center of the foundation trenches. as per direction of engineer incharge 46 Excavation for pipe line in all type of rock by chieselling /blastingincluding supply ofblasting materials and stacking properly useful materials with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 10 KMas per direction of engineer incharge 47 Dismantling and reinstatement of following type of surface including sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. as per direction of engineer incharge 48 INTERLOCKING ROAD 49 BITUMINOUS ROAD 50 C.C. ROAD 51 Carting from store (upto 8 Km) the following sizes of D.1. Pipes (class K-9) and AC pipes (class-15) and specials to the site of work, lowering them in to trenches and taying true to alignment and gradient including testing of pipeline D.I. (K-9) pipes 52 250 mm dia D.I.K-7 53 200 mm dia D.I K-7 54 Carting of following pipes, specials and fittings from site store to site of work, lowering them into trenches, laying true to alignment and gradient, laying and jointing with electro fusion fitting of pipe line including cutting of pipe for making up lengths as required for proper completion of work. 55 180 mm dia HDPE PN10/PE100 56 160 mm dia HDPE PN10/PE100 57 140 mm dia HDPE PN10/PE100 58 110 mm dia HDPE PN10/PE100 59 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge. Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 60 250 mm dia 61 200 mm dia 62 150 mm dia 63 100 mm dia 64 Carting of scour valves to the site of workslowering them into already Prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 65 80 mm dia 66 Carting of 50 mm dia screwed down air valves of following sizes to the site of workslowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 67 Carting of 80 mm dia flanges fire hydrant of the site of workslowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 68 Supply of all materials, labour T&P etc. required and construct masonry type sluice / scour valve chamber as per type design including supply and materials labour, T&P etc. complete. 69 Masonry type 70 Supply of all materials, labour T&P Etc. required and construct 350 x 350 x 500 mm size air valve chamber as per type design including supply and fixing the 500 mm dia CI manhole cover. 71 Supply of all materials, labour T&P Etc. required and construct 750 x 750 x 1000 mm size fire hydrant chamber as per type design including supply and fixing the 500 mm dia CI manhole cover. 72 Construction of thurst block in RCC 1:2:4 at bends & Tee in feeder main to DMAsincluding supply of all labour, material, T&P etc. complete as per the details given below :-No. of DMAs - 4Total no. of bends & Tee - 120 (considering 3 no. bends & Tee in each DMA)Qty. of concrete - 120 x 0.5 cum = 60 cum. (considering 0.5 cum concrete at each bend) 73 Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 74 Brick masonry in cement mortar 1:4 75 12mm thick plaster in cement mortar 1:4 76 Providing and laying in position reinforced cement concrete (mix 1:1.5:3)including batching, mixing, placing, vibrating, curing, formwork, finishing,including cost ofall material (Providing nominal reinforcement @ 0.15% of above itemincluding cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar)) and labour, tools and plants required with transportation, loading, unloading,etc., complete for all leads and lifts etc required for proper completion of the work. 77 Provision for crossing of Nalas (0.5mto 2.0 m width) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain. 78 0.3 - 0.5 m 79 0.5 - 1.0 m 80 1.0 - 1.5 m 81 1.5 - 2.0 m 82 Making House Connection in Distribution main including Dismantling of Road, Supply, carting of Specials lowering them into trenches, fixing them including bailing out of water necessary labour, T&P etc. required for proper completion of worksas per direction of engineer incharge 83 250 mm dia D.I.K-7 84 200 mm dia D.I K-7 85 180 mm dia HDPE PN10/PE100 86 160 mm dia HDPE PN10/PE100 87 140 mm dia HDPE PN10/PE100 88 110 mm dia HDPE PN10/PE100 89 Provision of Shifting water house hold connection. 90 For140 mmto 160 mm dia 91 For110 mm dia 92 Barricading of pipe line trenches by using 2 m high hard MS barricading board 2.5x2.0 M, with red flags, Glow-caution boards, diversion boards & red lights. 93 BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD 94 Construction of compound wall comprising of RCC Columns @ 3.0 m c/c distance with beam at plinth and top, brick work in 1:4 of as per type design including supply of all material, labour, T& P etc complete ( 2m height above plinth level 230 mm thick brick wall )as per direction of engineer incharge 95 Supply and fixing 3.60 m wide MS main gate & 1.0 m wide a wicket gate with RCC Columns as per type design & drawing including primer and painting, meterial, labour, T&P etc all complete, as per direction of engineer incharge 96 Supply and Carting of additional earth required to fill up the site to the required formation level At Zone -I and At Zone -II including leveling dressing ramming with proper compection work completed. as per direction of engineer incharge 97 Provide all materials, labour T&P etc. required for proper completion of work and construction of interlocking approach road in water works campous. At Zone -I and At Zone -IIas per direction of engineer incharge 98 Construction of 250X250 mm size drain at W/W sites At Zone -I and At Zone -IIas per direction of engineer incharge 99 GENERAL RESIDENTIAL QUARTERS 100 Construction of staff quarters (1 G.F) including other miscellaneous works. The plinth area of each staff quarter is 57.706 sqm. As per jal nigam type designas per direction of engineer incharge 101 construction ofStaff Quarter at Zone-I 102 construction ofStaff Quarter at Zone-II 103 E AND M WORKS 104 CONSTRUCTION OF NEW TUBEWELL (ZONE-1) 105 Resistivity and hydrological Survey 106 Transportation from store: 107 Transportation, Erection, Dismantiling of DC/RC/DTH Rig machine 108 Transportation, Erection, Dismantiling of 150 PSI Compressor 109 Transportation, Erection, Dismantiling of 1 Cusec / 3 Cusec OP Unit and Yield test 110 Drilling of Tube well bore : 111 Drilling and reaming of 600mm dia bore from GL to 60 m BGL by DC method 112 Bentonyte Powder Bags 113 Tube Well Assembly : 114 M.S. Tubewell Assembly with all required parts like planin pipe, slotted pipe, rings, well cap, bail plug, clamp, reducer, central guide, support structure etc. as required & per typed design complete in all respect. 115 300mm dia M.S.E.R.W. houseing plain pipe of wall thickness 7.1 mm. 116 Lowering of Tube well Assembly 117 Electrical logging of the bore 118 Lowering of 300mm. Dia M.S. housing pipe G.L. to 59 mtr. BGL 119 Supply of 1.6 to 4.8mm size pea gravel and shrouding of tube well 120 Development of Tube well 121 By Air Compressor 122 Development of Tube well by 150 PSI capacity air compressor 123 By Over Pumping Unit 124 Development of Tube well by OP Unit 125 Chemical & Bacteriological test of water 126 PUMPING MACHINARY TO FEED 400 KL OHT (ZONE-1) 127 SITC of Pumping Plant including, panel, cable, complete in all respect with all required material T&P labour etc. (1000LPM , 61 m Head , 2900RPM, 25 H.P) 128 SITC of Main piping & Valves with 24 mtr. Column pipe, Painting, Tools with wiring of pump house (internal & external) complete in all respect with required material, T&P labour, chain pully and gauges. - 150 mm dia 129 TOOLS (REPUTED MAKE ) IN A TOOL KIT - 1 Set1. Pipe wrenches - 2 No.2. D/E Spanner 22/6 mm - 6 Pcs3. Adjustable wrench 300 mm- 1No.4. Screw driver5. 250 mm- 1No.6. 200 mm - 1No.7. 150 mm- 1No.8. Combination pliers 200 mm- 1No.9. Nose pliers 150 mm - 1No.10.hammer with handle 1 kg.- 1No.11. Line tester (Taparia make)- 1No. 130 SITC of Soft Starter with RS 485 Port- 400 V Class, 18.5 KW, Rating 131 SITC of Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank. ( SCADA Compatible ) 132 SITC of Motor Operated Actuator with Sluice Valve - 150 mm size 133 SITC of CE/UL Certified Electromagnetic Flowmeter-150 mm size 134 SITC of Servo voltage stabilizer oil cooled having capacity 40 KVA fully copper winding three phase A.C supply 50 Hz. Input voltage 240-450 output voltage 415 volt +/- 1% withearthling wire and power cable 135 SITC of Auto Phase reversal unit with inbuilt time delay & enclousare ( confirm to IEC:60947-1 & IEC:-60947-b-1) 136 125 Amp Rating 137 ElectricalWorksfor Zone-1 138 Electrical System ( For Tubewell ) 139 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - internal & external lighting of 01 tubewell as follows:- 140 Indoor Lighting 141 Surface Mounting 142 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 143 Suspended Mounting / Surface Mounting 144 36W LED light fixture 2×2 with acrylic / prismatic front cover. 145 Outdoor Lighting 146 Supply and fixing of all in one solar LED light fixture with integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 147 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W for TW & MCS 148 Complete wiring of Pump house with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 149 Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories 150 Electrical System ( MCS ) 151 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - internal & external lighting of MCS as follows:- 152 Indoor Lighting 153 Surface Mounting 154 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 155 Suspended Mounting / Surface Mounting 156 36W LED light fixture 2×2 with acrylic / prismatic front cover. 157 Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required.(For MCS) 158 450mm sweep (900/1400 RPM) 159 Outdoor Lighting 160 Supply and fixing of all in one solar LED light fixture with integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 161 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W for TW & MCS 162 Complete wiring of MCS with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 163 Instrumentation Worksfor Zone-1 164 Automation of Proposed OHT ( 400 KL ) with DMA 165 Supply of Motor operated actuator without sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater without sluice valve (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 166 250 mm dia 167 Supply of flow control valve with electric actuator for flow controling,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. 168 200 mm 169 Supply of dismantling joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. 170 200 mm 171 Supply of CE/UL Certified level transmitter for OHT :- Supply of Radartype leveltransmitter with CEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 172 Supply of CE/UL Certified Electromagnetic flow meter at DMA inlet :- SupplyofCE/ULFullBore ElectromagneticFlowMeterofapproved make for remote placesof following dia and specificationscomplete:Media: Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable and also interfacing with PLC panel. 173 200 mm dia 174 Supply of CE/UL Certified Pressure transmitter at DMA inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 175 Supply of Dosing System at DMA inlet :-Supply of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible ) 176 Supply of Residual chlorine analyser / meter at DMA inlet :-Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V ac+B7Output : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must beprovided to avoid maintenance. IP 65 Nema 4 housing protection class required. 177 Installation, cabling of OHT including all equipments with all power and control cable,testingand commissioning complete in all respect. 178 Master Control Station (MCS) 179 CE & BIS approved manufacturers industrial grade LCD monitor with latest configuration as per specification of size 65 180 Desktop/PC as per spec. mentioned 181 CE/UL approved manufacturers 5 KVA UPS with batteries as spec. mentioned for Computer as per requirement 182 Full development version of required TAGS SCADA Software with customization of software for MCS as per requirement as per specification mentioned. 183 CE & UL approved manufacturers control room PLC with CPU & power supply at MCS in IP65 enclosure as per spec. mentioned 184 CE/UL certified field gateway agent for transfering data from MCS to control room 185 GSM based wireless / broadband/Equipment communication system for PLC capable to transfer and gather data from remote sites to control stations, including all accessories complete 186 CE/UL approved manufacturers Firewall for network protection 187 Lightning surge protector for ethernet communication protection 188 CE/UL approved manufacturers industrial grade ethernet switch 189 Mobile App facility system architecture complete. 190 Canon/HP 1018/equivalent Laser printer 191 Security Survelliance IP camera 192 Installation, testing and commissioning with required furniture,Air Conditioner etc 193 Automation of Tubewells (Zone-1) 194 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 195 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 196 CE & UL certified Inteligent Smart Energy Meter 197 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 198 CE & UL certified pressure transmitter 199 CE & UL certified Surge protector for above control panel 200 CE/UL approved manufacturers 3 KVA UPS with batteries as spec. mentioned for Computer as per requirement 201 CE & UL certified 7 HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 202 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT both. 203 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 204 Installation, commissioning & testing for tubewells 205 AUTOMATION OF DMA (ZONE-1) 206 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit withCPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 207 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 208 CE/UL Certified Intelligent energy meters 209 CE/UL Certified Surge protector for control panel 210 CE/UL Certified 1 KVA UPS with batteries as per technical bid documents 211 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 212 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 213 Cable 214 (i) Complete cabling 215 Security Survelliance IP Camera with recorder (optional) 216 Installation, commissioning & testing 217 CONSTRUCTION OF NEW TUBEWELL ( ZONE-2) 218 Resistivity and hydrological Survey 219 Transportation from store: 220 Transportation, Erection, Dismantiling of DC/RC/DTH Rig machine 221 Transportation, Erection, Dismantiling of 150 PSI Compressor 222 Transportation, Erection, Dismantiling of 1 Cusec / 3 Cusec OP Unit and Yield test 223 Drilling of Tube well bore : 224 Drilling and reaming of 600mm dia bore from GL to 60 m BGL by DC method 225 Bentonyte Powder Bags 226 Tube Well Assembly : 227 M.S. Tubewell Assembly with all required parts like planin pipe, slotted pipe, rings, well cap, bail plug, clamp, reducer, central guide, support structure etc. as required & per typed design complete in all respect. 228 300mm dia M.S.E.R.W. houseing plain pipe of wall thickness 7.1 mm. 229 Lowering of Tube well Assembly 230 Electrical logging of the bore 231 Lowering of 300mm. Dia M.S. housing pipe G.L. to 59 mtr. BGL 232 Supply of 1.6 to 4.8mm size pea gravel and shrouding of tube well 233 Development of Tube well 234 By Air Compressor 235 Development of Tube well by 150 PSI capacity air compressor 236 By Over Pumping Unit 237 Development of Tube well by OP Unit 238 Chemical & Bacteriological test of water 239 PUMPING MACHINARY TO FEED 450 KL OHT (ZONE-2) 240 SITC of Pumping Plant including , panel, cable, complete in all respect with all required material T&P labour etc. (1000LPM , 61 m Head , 2900RPM, 25H.P) 241 SITC of Main piping & Valves with 24 mtr. Column pipe, Painting, Tools with wiring of pump house (internal & external) complete in all respect with required material, T&P labour, chain pully and gauges. - 150 mm dia 242 TOOLS (REPUTED MAKE ) IN A TOOL KIT1. Pipe wrenches - 2 No.2. D/E Spanner 22/6 mm - 6 Pcs3. Adjustable wrench 300 mm - 1 No.4. Screw driver5. 250 mm - 1 No.6. 200 mm- 1 No.7. 150 mm - 1 No.8. Combination pliers 200 mm - 1 No.9. Nose pliers 150 mm - 1 No.10. hammer with handle 1 kg. - 1 No. 243 SITC of Soft Starter with RS 485 Port- 400 V Class, 18.5 KW, Rating 244 SITC of Supply and fixing of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank. ( SCADA Compatible ) 245 SITC of Motor Operated Actuator with Sluice Valve - 150 mm size 246 SITC of CE/UL Certified Electromagnetic Flowmeter-150 mm size 247 SITC of Servo voltage stabilizer oil cooled having capacity 40 KVA fully copper winding three phase A.C supply 50 Hz. Input voltage 240-450 output voltage 415 volt +/- 1% withearthling wire and power cable 248 SITC of Auto Phase reversal unit with inbuilt time delay & enclousare ( confirm to IEC:60947-1 & IEC:-60947-b-1) 249 125 Amp Rating 250 Electrical Worksfor Zone-2 251 Electrical System ( For Tubewell ) 252 Complete lighting system including energy efficient lighting fixtures, lighting poles, wires, conduits, cables, and necessary accessories - internal & external lighting of 01 tubewell as follows:- 253 Indoor Lighting 254 Surface Mounting 255 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 256 Suspended Mounting / Surface Mounting 257 36W LED light fixture 2×2 with acrylic / prismatic front cover. 258 Outdoor Lighting 259 Supply and fixing of all in one solar LED light fixture with integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system. 260 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W for TW 261 Complete wiring of Pump house with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 262 Complete earthing / lightning protection system including earth electrode, earth strip, wires, junction box for test links, treated and non-treated earth pits, etc. with necessary accessories 263 Instrumentation Worksfor Zone-2 264 Automation of Proposed OHT ( 450 KL ) with DMA - Zone-2 265 Supply of Motor operated actuator without sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater without sluice valve (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 266 250 mm dia 267 Supply of flow control valve with electric actuator for flow controling,pressure monitoring and web based with cable PLC etc Complete at DMA inlet. 268 200 mm 269 Supply of dismantling joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. 270 200 mm 271 Supply of CE/UL Certified level transmitter for OHT :- Supply of Radartype leveltransmitter with CEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 272 Supply of CE/UL Certified Electromagnetic flow meter at DMA inlet :- SupplyofCE/ULFullBore ElectromagneticFlowMeterofapproved make for remote placesof following dia and specificationscomplete:Media: Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable and also interfacing with PLC panel. 273 200 mm dia 274 Supply of CE/UL Certified Pressure transmitter at DMA inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 275 Supply of Dosing System at DMA inlet :-Supply of Electro Mechanical type Chemical dosing system 0 to 6 LPH capacity on working pressure 4kg/cm2 to feed Sodium hypo chloride complete set with 100 Litre solution tank.( SCADA Compatible ) 276 Supply of Residual chlorine analyser / meter at DMA inlet :-Supply of RCA must have automatic sensor cleaning facility at pure water sump and Interfacing with PLC panel. Residual Chlorine meter shall comprises of 3 components i.e. sensors, flow through assembly and transmitter with indicator andgives 2 outputs one to Local display & other to PLC including Mounting arrangement.Overall Range : 0 - 8 mg/l (ppm)Accuracy : 2% of full scaleSupply Voltage : 230 V ac+B7Output : 4-20 mAMembrane free sensor of 2 gold plated electrodes for long term stability and reference electrode (ag/Agcl) must beprovided to avoid maintenance. IP 65 Nema 4 housing protection class required. 277 Installation, cabling of OHT including all equipments with all power and control cable,testingand commissioning complete in all respect. 278 Automation of Tubewells (Zone-1) 279 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 280 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 281 CE & UL certified Inteligent Smart Energy Meter 282 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 283 CE & UL certified pressure transmitter 284 CE & UL certified Surge protector for above control panel 285 CE/UL approved manufacturers 3 KVA UPS with batteries as spec. mentioned for Computer as per requirement 286 CE & UL certified 7 HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 287 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT both. 288 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 289 Installation, commissioning & testing for tubewells 290 AUTOMATION OF DMA (ZONE-2) 291 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit withCPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 292 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 293 CE/UL Certified Intelligent energy meters 294 CE/UL Certified Surge protector for control panel 295 CE/UL Certified 1 KVA UPS with batteries as per technical bid documents 296 CE/UL Certified 7 touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 297 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 298 Cable 299 (i) Complete cabling 300 Security Survelliance IP Camera with recorder (optional) 301 Installation, commissioning & testing 302 TRAIL & RUN (Without Electricity) for03 Months Trial & Run for Zone-1,2
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
47.
Communications and Information Technology  #9443773 Technical Bid
tender for Annual maintenance contract Of Existing Application With Upgradation And Development Of New Module With One Year Technical Support And Biometric Machines And Associated Items For Jalkal Department, Nagar Nigam Kanpur (U.P), 1 Design and Development of Public Grievances Management Module 2 Design and Development of RTI Management Module 3 Design and Development of Legal Cases Management Module 4 Design and Development of Water Tanker Booking Module 5 Design and Development of Pension management Module 6 Design and Development of Attendance Management System using biometric machines 7 Payment Gateway Integration (Per Payment Gateway Per Bank) 8 Charges for SMS (@per SMS) 9 PoS machine integration (per bank) 10 Security Audit of complete application through Cert-in empaneled service provider (Half yearly basis) 11 SSL (Annually) 12 Cloud Services for one year (Detail mentioned in technical proposal) 13 Onsite Technical Support Services (per person per annum) 14 Biometric Machines and associated items with One Year Warranty 15 PoE based Attendance Machine with Face Recognition + EMPROX Smart Card + Pin and Access Control 16 Wired Mesh box for above Biometric Machine 17 8-Port PoE Switch 2 SFP with min 120W Switch 18 24 Port UTP CAT6 Patch Panel with 8 keystone populated 19 UTP CAT6 patch card 1M 20 UTP CAT6 Information Outlet with Surface Mount Box with Shutter 21 UTP CAT6 cable (305 meter) per box 22 Network rack 6U 23 1KVA LI-UPS with 30 min backup 24 Installation of Biometric Devices at each location along with Mounting Cage 25 Data Entry of Employee and Capturing of face image/ fingerprint of each individual employee. (One-time data feeding per employee). At start we will mark 50 data feeding into the system rest shall be marked by the department else additional charges shall be applied on pro-rata basis 26 Total 27 UPDESCO margin@10% 28 Total Cost including UPDESCO margin 29 GST@18% 30 Overall cost including taxes (A+B) 31 AMC Cost 2nd Year and onwards: 32 Work Description 33 <2> 34 AMC cost of Existing Software after Upgradation - Online Water/ Sewer Tax Management System - Online Water/Sewer Connection form and JKK Website (www.jalkalkanpur.in) - PIS and Payroll Management - Role based User Management Module- Development of Dashboard and MIS report mechanism- Upgradation of Water/ Sewer Tax Billing Application.- Upgradation of online application for new water and sewer connections 35 AMC of Android based Mobile application with Google Services 36 AMC of Public Grievances Management Module 37 AMC of RTI Management Module 38 AMC of Legal Cases Management Module 39 AMC of Water Tanker Booking Module 40 AMC of Pension management Module 41 AMC of Attendance Management System using biometric machines 42 Charges for SMS (@per SMS) 43 PoS machine integration (per bank) 44 Security Audit of complete application through Cert-in empaneled service provider per Annum (Twice in a year) 45 SSL (Annually) 46 Cloud Services for one year (Detail mentioned in Sec- III (3) Scope of work) 47 Onsite Technical Support Services (per person per annum) (optional) 48 AMC of Biometric Machines and associated items 49 AMC of Biometric Machines and associated items (Mentioned at Sr. No. B1 to B11inabove Table) after completion of One Year Warranty (@per Annum) 50 Total 51 UPDESCO margin@10% 52 Total Cost including UPDESCO margin 53 GST@18% 54 Overall cost including taxes (C+D)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
49.
Defence #9398091 Price Bid
Regarding Digital Trunking Wireless Communication , Main Control Room Equipments (Master Site): , Digital Open Standard Radio Trunking System Control And Switching Equipment (Tscse) Ip Based With Complete Hot Standby. , Network Management System Comprising Of Network Management Server (Nms) And Network Management Terminals (Nmt) With Two Clients , Aes 256 Encrypted Dispatch Consoles Collocated At Central Police Control Room , Aes 256 Encrypted Dispatch Consoles Collocated At Hot Standby Site. , 25 Channels Ip Based Digital Voice Logger System , Hardware And Software For Avls/Apls Server And Client , 50 Or Betterled Monitor Of Reputed Make For Avls/Apls , Telephone Interconnect Gateway With E1 Over Qsig/Sip Over Ip Based , Unified Threat Management (Utm) For Connecting Cpcr With Mirror Site. , Repeater/ Base Station Equipments: Sufficient Number Of Repeater Stations In 400/800 Mhz With Required Configurations Redundant Repeater Site Controller, Masts/ Towers Of Required Height, Antenna System, Transmitter Combiner, Receiver Multicoupler, Tower Top Amplifier, Couplers, Cables, Surge, Interfaces And Lightning Protection System, Accessories Etc (Bidder To Specify As Per Appendix-30) , Antenna Masts/ Towers As Per Specifications (Bidder To Specify As Per Appendix-30 ) , Redundant 7/13/15 Ghz Microwave Links To Connect All Repeater Stations To Master Site With Necessary Tower And Accessories. (Bidder To Specify As Per Appendix-30 ) , Full Alphanumeric Keypad Static Radio With Gps, Aes 256 Encryption And Accessories As Per Technical Specifications. , Full Alphanumeric Keypad Mobile Radio With Gps, Aes 256 Encryption And Accessories As Per Technical Specifications. , Full Alphanumeric Keypad Portable Radio With Gps, Aes 256 Encryption, Belt Clip, Li-Ion Or Better Battery, Single Unit Battery Charger And Accessories As Per Technical Specifications. , 06 Way Or Better Position Rapid Multi Unit Chargers , Spare Li-Ion 2100 Mah Or Better Batteries , Light Weight Speaker Microphone, Earphone With Clip, Complete Hand Free Kit For Each Hand Held Radio , Suitable Carrying Case , Headset For Portables , Vehicular Charger For Portable Radios , Digital Vehicular Repeater System (For Coverage Enhancement) With All Accessories. , Programming Kits: , Repeater / Base Station Equipments , Static Radios , Mobile Radios , Portable Radios , Inter Site Link Test Equipments , Portable Programming Laptop For Repeaters And Master Switch , Latest Aes With Minimum 256 Bits Encryption Infrastructure And Key Management System: , Key Loader With Interface Cables , Commensurate Capacity 1+1 Redundant Online Ups’S For All Offered Equipments With Phase Changeover Switch For Ups And Direct Mains With Maintenance Free Battery Bank For 8 Hours Backup For: (Bidder To Specify As Per Appendix-30 ) , For All Repeater Sites(Bidder To Specify As Per Appendix-30) , Central Police Control Room.(Bidder To Specify As Per Appendix-30 ) , Test Equipments/ Tools: , Radio Communication Test Set For Trunked Radio System. , Through Line Power Meter , Any Other Item Required For Field Testing , Temperature Maintenance System: (Bidder To Specify As Per Appendix-30) , Sufficient Numbers Of Environment Control System At All Repeater Sites With Automatic Change Over Every 6 Hours. (Bidder To Specify As Per Appendix-30 ) , Sufficient Numbers Of Environment Control System At Switching Centre With Automatic Change Over Every 6 Hours. (Bidder To Specify As Per Appendix-30 ) , Miscellaneous: , Earthing Equipment (Bidder To Specify As Per Appendix-30) , Transient Protection Equipment (Bidder To Specify As Per Appendix-30) , Manuals Of System Components, Tscse, Repeater Radios, Static/Mobile Radios, Portable Radios, Digital Voice Logger, Antenna System, Inter Site Link Equipments Etc.: , Operating Manuals , Service / Maintenance Manuals , Programming Manuals , Any Other Hardware/Software/System Equipment Required To Meet The Technical Specifications And Requirements Of The Tender (Bidder To Specify As Per Appendix-30) , Services (Bidder To Specify As Per Appendix-30) , Project Management, Installation, Commissioning, Programming, Acceptance Testing , Master And Repeater Sites Preparation Alongwith Cable Tray Inside The Room, Power Cabling,Earthing, Surge Protectors And Any Other Necessary Civil/Electricalcomponent Required For Infrastructure Etc. , Three Years On Site Comprehensive Warranty And Seven Years Camc For All Equipment’S (Except Batteries) , Training , Repair/ Maintenance Training At The Manufacturer Premises , Repair/ Maintenance Training At The Premises Of Purchaser , User Operational Training At The User’S Location , Civil/Electrical Work At Each Repeater Sites Based On The Network Design And Assessment Of The Bidder , Charges Of Repeater Sites: Rental Charges (For Sites Other Than Chandigarh Police Establishments), Electricity Charges And Technical Manpower Charges. , Payment Of Year01 Of Camc (I.E. 4Rd Years) , Year 2 Of Camc , Year 3 Of Camc , Year 4 Of Camc , Year 5 Of Camc , Year 6 Of Camc , Year 7 Of Camc , Payment Will Be Released In Three Phases I.E. 40% + 40 % + 20%
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
50.
Public Administrative Department #9381058 Technical Bid
Tender For Rate Call For Various Items For Mc Washim .- 1 Garden Items 2 Patterned LED Pathway Light Providing, supplying, installing, testing and commissioning decorative patterned LED pathway light, having die-cast aluminium /powder-coated MS body, fitted with special optical lens / perforated shade / gobo for patterned ground illumination, complete withhigh-efficiency LED module (5W–10W) and electronic constant-current driver, operating on 230V ±10%, 50Hz AC supply, with luminous efficacy 90 lm/W, CCT 3000K / 4000K, CRI 80, glare-free soft illumination, and minimum IP65 protection suitable for outdoor applications. The item includes mounting on concrete base / spike mount, concealed wiring through PVC conduit, junction boxes, earthing, all hardware and accessories, testing and commissioning, and making good the surrounding area, complete in all respects as per approved specifications and directions of the Engineer-in-Charge. 3 Cement Carving Design Including proper work as per Design, after setting of carving design work do proper washing after that apply Primer & then Colouring with proper precautions. 4 Decorative Green Tunnel / Creeper Arch with Integrated Lighting Providing, supplying, fabricating and erecting decorative green tunnel / creeper arch walkway made of galvanized iron (GI) / MS welded mesh and tubular frame, shaped in continuous arch form, suitable for supporting climbers and creeper plants. The structure shall be fixed on RCC / PCC footings with necessary anchoring. Item includes integrated LED strip / spike lighting fixed along the arches for ambient illumination, complete with drivers, wiring, junction boxes and earthing. Work also includes anti-corrosive treatment, painting, plantation support, all fittings, accessories, excavation, concreting and making good the area, complete in all respects as per approved drawings, specifications and directions of Engineer-in-Charge. 5 Mughal Style Garden Arch / Partition Wall Providing, constructing and finishing Mughal style decorative garden arches to be used as visual and functional partitions within the garden, constructed in brick masonry with RCC arch beams, columns and lintels as required for structural stability. The arches shall be proportioned in traditional Mughal architectural style with symmetrical profiles. Exposed faces shall be finished with hand-carved /machine-carved natural stone cladding of approved pattern and thickness, including ornamental mouldings and detailing. Item includes RCC work, brickwork, centering and shuttering, stone carving, fixing with mortar, curing, scaffolding and making good, complete in all respects as per approved drawings, specifications and directions of Engineer-in-Charge. 6 Providing and fixing non-slip EPDM rubber flooring / artificial grass / Kota stone flooring over prepared base with necessary adhesive, joints and finishing complete. 7 Yoga MatProviding and placing yoga mats made of high-quality non-slip EVA / TPE / rubber material, of approved make, size and thickness (minimum 6 mm), washable, sweat-resistant and suitable for outdoor / indoor yoga use. Item includes supply, stacking and placing at designated yoga ground area, complete in all respects as per directions ofEngineer-in-Charge. 8 Automatic Soil-Moisture Sensor Based Lawn Sprinkler System Providing, supplying, installing, testing and commissioning special type automatic lawn sprinkler system operated through soil moisture sensor–based controller, which automatically starts and stops irrigation based on soil moisture condition. System shall comprise pop-up / rotary sprinklers of approved make, underground HDPE / PVC piping network, control valves, moisture sensors, timer / controller unit and necessary fittings. Item includes excavation, laying and jointing of pipes, backfilling, electrical connections (if required), testing, calibration and making good the lawn area, complete in all respects as per approved drawings, specifications and directions of Engineer-in-Charge. 9 Theme-based Indication Sign Boards for Public GardenProviding and fixing theme-based indication sign boards in various shapes and sizes for public garden directions and information. Boards to be made of durable, weather-resistant materials such aspowder-coated MS sheet / high-density PVC / treated wood, suitable for outdoor exposure. Boards to have clear, legible text with high-contrast colors and universal symbols/icons for easy readability. Shapes and sizes to be varied as per theme, including main entrance boards,area-specific boards, and pathway indicators. All boards to be fixed on suitable supports (MS posts, wooden posts, or wall mounts) with proper alignment and height for visibility. Surface finish to be smooth, weatherproof, and fade-resistant. Work includes design, fabrication, transportation, and installation complete as per site requirement and PWD standards. 10 LED Bollard / Pathway LightProviding, supplying, installing, testing and commissioning LED bollard light fitting suitable for garden paths, walkways and landscape areas, made of powder-coated aluminium / MS body with opal polycarbonate diffuser, complete with integrated energy-efficient LED module and electronic driver, operating on 220–240 volts, 50 Hz AC supply, consuming 8 W to 15 W power, having minimum light output of 700 lumens, CRI  80, power factor  0.90, CCT 3000K / 4000K, IP65 protection, IK07 impact resistance, surge protection  4 kV, and LED life  50,000 burning hours. The fixture shall be surface mounted on firm concrete base including anchor bolts, with concealed FRLS copper wiring, weatherproof junction box, proper earthing, glands, connectors, hardware, all accessories, making good damaged surfaces, and testing and commissioning complete, as per PWD specifications, approved drawings, and directions of Engineer-in-Charge. 11 Decorative Urban Light FixtureProviding, supplying, installing, testing and commissioning decorative sculptural outdoor light fixture inspired by organic tree / flower form, comprising multiple curved tubular arms fabricated from powder-coated MS / SS structure, mounted on a rigid central pole, complete with translucent opal polycarbonate / toughened glass diffuser heads housing integrated energy-efficient LED light sources. The fixture shall operate on 220–240 volts, 50 Hz AC supply, with total connected load not exceeding 100 watts (or as approved), complete with high-efficiency electronic driver, internal concealed wiring, and surge protection device, having minimum IP65 ingress protection, uniform glare-free illumination, CRI  80, power factor  0.90, and LED life  50,000 burning hours, suitable for continuous outdoor operation. The luminaire shall be surface mounted on RCC foundation and pedestal including base plate, foundation bolts, anchor fasteners, proper earthing, weatherproof junction box, glands, connectors, all required accessories, making good damaged pavement / landscaped area, and testing and commissioning complete, as per PWD specifications, approved drawings, and directions of Engineer-in-Charge. Rate shall include cost of fixture, foundation, materials, labour, tools, scaffolding, transportation, taxes, levies, testing, commissioning and all incidental works, complete. 12 Wooden Gazebo / Garden Pavilion (5.0 m × 5.0 m × 4.0 m) Providing, supplying, constructing and installing wooden gazebo / garden pavilion of approved design and dimensions including treated hardwood structural members, roofing, flooring, seating, foundations, anti-termite treatment, finishing and making good surrounding area,complete as per PWD specifications, approved drawings and directions of Engineer-in-Charge. 13 Decorative Wooden / WPC Garden Arch / Entrance Gateway Providing, supplying, fabricating and erecting decorative garden arch / entrance gateway of approved design and dimensions using treated hardwood / engineered wood / WPC members, fixed on RCC / PCC foundation blocks including fittings, finishing and making good area, complete as per PWD specifications and directions ofEngineer-in-Charge. 14 Meditation / Tranquility Fountain (Low Noise Type)Providing, supplying and installing meditation / tranquility type low-noise water fountain with slow cascading / bubbling water feature comprising sculpted body, RCC base, pump, concealed piping, electrical connections, testing and commissioning, and making good the surrounding area, complete in all respects as per approved specifications and directions of Engineer-in-Charge. 15 Decorative Solar LED Sculptural Light PolesProviding, supplying, erecting, testing and commissioning decorative sculptural solar LED light poles with integrated solar panel, battery, charge controller, RCC foundation, fittings and making good the surrounding area, complete as per approved drawings and directions of Engineer-in-Charge. 16 Tensile Shade Structure / Canopy (Parking / Walkway Shelter) Providing, supplying, fabricating, erecting, testing and commissioning tensile shade structure / canopy comprising MS framework, tensile membrane roofing, RCC foundations, fittings, accessories and making good surrounding area, complete as per approved drawings and directions of Engineer-in-Charge. 17 Mughal Style Garden Arch / Partition Wall (GRC Construction) Providing, supplying, fabricating, erecting and finishing Mughal style decorative garden arches / partition walls in Glass Fibre Reinforced Concrete (GRC), including support framework, panels, detailing, anchoring, jointing, finishing and making good area, complete as per approved drawings and directions of Engineer-in-Charge. 18 WPC / WPVC Gazebo / Garden Pavilion (5.0 m × 5.0 m × 4.0 m) Providing, supplying, constructing and installing WPC / WPVC gazebo / garden pavilion including structural members with MS reinforcement, roofing, flooring, foundations, fixings, finishing and making good surrounding area, complete as per PWD specifications, approved drawings and directions of Engineer-in-Charge. Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
TenderDetail
Loading tenders